10/98 OPERATION MANUAL MANUAL NO. 057-196-00 REV. NO. Q LAB-LINE® EXPLOSION-PROOF, FLAMMABLE MATERIAL STORAGE, & GENERAL-PURPOSE LABORATORY REFRIGERATORS, REFRIGERATOR/FREEZERS, AND FREEZERS MODEL NOs. 3551 3556 3560 3762 3551-1 3556-1 3560-1 3762-1 3551-10 3556-2 3560-10 3763K 3551-11 3556-4 3560-11 3763B 3552 3556-6 3750 3763-1 3552-1 3557 3750-1 3764 3552-10 3557-1 3750-2 3764-1 3552-11 3557-2 3751 3766 3555 3557-3 3751-1 3766BR3X 3555-1 3557-4 3751BK 3766-1 3555-6 3557-5 3767B 3767 3555-7 3559 3752 3767BR3X 3559-10 3559-1 3752P2 3767R17 3559-11 3752R17 3752-1 3767-1 3764L 3750V 3761 3770 3750K 3763BXK 3761-1 3752-2 3767BR17 3556-6K 3566-1 3566-10 3557-4K 3751R27 3566 3566-11 3551KL 3763(L) 3764K 3751L 3751LFS 3556X 3763XR27 3556-4X LAB-LINE INSTRUMENTS, INC. DESIGNERS AND MANUFACTURERS 15th and Bloomingdale Aves. , Melrose Park, IL 60160-1491 USA PHONE: 708/450-2600 1-800/LAB-LINE FAX: 450-0943

OPERATION MANUAL - archive-resources.coleparmer.com · this manual. • Be sure to fill out the Warranty Registration Card and mail it in to Lab-Line Instruments within seven (7)

  • Upload
    others

  • View
    2

  • Download
    0

Embed Size (px)

Citation preview

Page 1: OPERATION MANUAL - archive-resources.coleparmer.com · this manual. • Be sure to fill out the Warranty Registration Card and mail it in to Lab-Line Instruments within seven (7)

10/98

OPERATION MANUALMANUAL NO. 057-196-00

REV. NO. Q

LAB-LINE®

EXPLOSION-PROOF,FLAMMABLE MATERIAL STORAGE,

& GENERAL-PURPOSE LABORATORYREFRIGERATORS, REFRIGERATOR/FREEZERS,

AND FREEZERS MODEL NOs. 3551 3556 3560 3762

3551-1 3556-1 3560-1 3762-13551-10 3556-2 3560-10 3763K3551-11 3556-4 3560-11 3763B3552 3556-6 3750 3763-1 3552-1 3557 3750-1 3764 3552-10 3557-1 3750-2 3764-1 3552-11 3557-2 3751 3766 3555 3557-3 3751-1 3766BR3X

3555-1 3557-4 3751BK 3766-13555-6 3557-5 3767B 37673555-7 3559 3752 3767BR3X3559-10 3559-1 3752P2 3767R173559-11 3752R17 3752-1 3767-13764L 3750V 3761 3770

3750K 3763BXK 3761-1 3752-2 3767BR17 3556-6K 3566-1 3566-10 3557-4K 3751R27 3566 3566-11 3551KL 3763(L) 3764K 3751L 3751LFS 3556X 3763XR27 3556-4X

LAB-LINE INSTRUMENTS, INC.DESIGNERS AND MANUFACTURERS15th and Bloomingdale Aves. , Melrose Park, IL 60160-1491 USA

PHONE: 708/450-2600 • 1-800/LAB-LINE • FAX: 450-0943

Page 2: OPERATION MANUAL - archive-resources.coleparmer.com · this manual. • Be sure to fill out the Warranty Registration Card and mail it in to Lab-Line Instruments within seven (7)

2

TABLE OF CONTENTS

Page 3: OPERATION MANUAL - archive-resources.coleparmer.com · this manual. • Be sure to fill out the Warranty Registration Card and mail it in to Lab-Line Instruments within seven (7)

3

SECTION TITLE

1 Introduction

2 Explosion-Proof units

3 Flammable Materials Storage units

4 Corrosion-Resistant units

5 General Purpose Laboratory units

6 Installation

7 Operation

8 Troubleshooting

9 Maintenance

10 Optional Gauge Steel Frame Appliance Dolly

11 Optional Vapor Proof Outlet

12 Replacement Parts

Warranty

SECTION 1

INTRODUCTION

Page 4: OPERATION MANUAL - archive-resources.coleparmer.com · this manual. • Be sure to fill out the Warranty Registration Card and mail it in to Lab-Line Instruments within seven (7)

4

THANK YOUfor selecting Lab-Line Instruments for your equipment needs. For maximum value andease of start-up,

PLEASE PROCEED AS FOLLOWS:• Inspect the carton and contents for shipping damage. Notify the carrier immediately

if damage is found.• Use the Accessory Checklist when unpacking to verify that the complete unit has

been received. Do not discard packing materials until all is accounted for.• Read this Operation Manual thoroughly before deciding upon an appropriate location

for the unit: you will want to consider the availability of power, water, hook-ups,drains and other unit requirements, as well as user convenience.

• Insist that every operator of this unit becomes familiar with the Operation Section ofthis manual.

• Be sure to fill out the Warranty Registration Card and mail it in to Lab-LineInstruments within seven (7) days after receiving the unit.

IFafter reading this manual you should have any difficulties with the installation oroperation instructions, please call:

Lab-Line Customer Relations Department 708/450-2600 (in Illinois) 1-800/LAB-LINE (elsewhere)

ALL RIGHT RESERVEDThe information contained in this manual is the exclusive property of Lab-Line Instruments, Inc., and has been pro-vided solely to enable the users of the equipment described herein to operate and maintain such equipment. Anyother use of this information, or the reproduction or transmission of all or any portion of this manual without priorwritten consent of the manufacturer is expressly prohibited. © 1998, Lab-Line Instruments, Inc.

SECTION 2

EXPLOSION-PROOFREFRIGERATORS & FREEZERS

Page 5: OPERATION MANUAL - archive-resources.coleparmer.com · this manual. • Be sure to fill out the Warranty Registration Card and mail it in to Lab-Line Instruments within seven (7)

5

BE ADVISED:DANGER: UNLESS UNIT IS SPECIFICALLY DESIGNED FOR COMBUSTIBLE ORFLAMMABLE ATMOSPHERES, DO NOT USE IN THE PRESENCE OF FLAMMABLEOR COMBUSTIBLE MATERIALS OR EXPLOSIVE GASES; DO NOT USE IN THEPRESENCE OF PRESSURIZED OR SEALED CONTAINERS—FIRE OR EXPLOSIONMAY RESULT CAUSING DEATH.

WARNING: DO NOT HEAT ANY SUBSTANCE ABOVE A TEMPERATURE THATWILL CAUSE IT TO EMIT TOXIC FUMES—DEATH OR SEVERE INJURY MAYRESULT.

WARNING: BEFORE CONNECTING THE FINAL POWER SUPPLY, CHECK THEELECTRICAL CHARACTERISTICS OF THE UNIT NAMEPLATE TO SEE THAT IT ISIN AGREEMENT WITH THE POWER SUPPLIED. IN ADDITION, POWER SHOULD BEWIRED TO THE UNIT ACCORDING TO THE ELECTRICAL SCHEMATIC AND ALLAPPLICABLE CODES. ONLY QUALIFIED ELECTRICIANS SHOULD WORK ON THEELECTRICAL PORTION OF ANY UNIT INSTALLATION.

CAUTION: SOLUTIONS USED TO CLEAN COILS OR NEUTRALIZE BACTERIAGROWTH MUST NOT BE CORROSIVE TO METALS (ENAMEL-COATED STEEL)AND MATERIALS USED IN THE MAINTENANCE OF THIS EQUIPMENT—DAMAGECAN RESULT: USE A SOFT CLOTH AND WARM WATER TO CLEAN.

WARNING: STORAGE BY USER OF ANY MATERIALS IN THE PRODUCT WHICHMAY CAUSE A DETERIORATION OF THE PRODUCT SHALL BE DEEMED TOCONSTITUTE ABNORMAL AND IMPROPER USAGE OF THE PRODUCT FORPURPOSES OF LAB-LINE’S WARRANTY.

EXPLOSION-PROOF REFRIGERATORS &FREEZERS: (Con’t)

√SHIPPING CARTON:This should be inspected upon delivery. When received, carefully

examine for any shipping damage before unpacking. If damage is discovered, the delivering carrier should both specify and sign for the damage on your copy of the delivery receipt.

Page 6: OPERATION MANUAL - archive-resources.coleparmer.com · this manual. • Be sure to fill out the Warranty Registration Card and mail it in to Lab-Line Instruments within seven (7)

6

Open the carton carefully making certain that all parts are accounted for before packaging materials are discarded—after unpacking, if damage is found promptly report it to the carrier and request a damage inspection promptly.

IMPORTANT: Failure to request an inspection of damage within a few days after receipt of shipment absolves the carrier from any liability for damage: you must call for a damage inspection promptly.

AN OVERVIEW: THE FULL LINE FROM LAB-LINE: EXPLOSION-PROOFREFRIGERATORS AND FREEZERS.

Conventional refrigerators and freezers are not only unsuitable for storing flammable materials, they can create potential hazards in a facility. Such units have several components in their electrical and refrigeration systems which can trigger explosions of flammable air-vapor mixtures inside the unit or from the immediate surrounding area.

Lab-Line offers the largest explosion-proof selection in the industry, including single and 2-door upright refrigerators and freezers, horizontal chest freezers, and undercounter refrigerators.

Motors and thermostats are designed to prevent the arcing which can ignite a flammable air-vapor mixtures, In addition, each unit has wiring, splices, a thermostat, a relay and a compressor motor safely housed within an explosion-proof enclosure of construction suitable for use in Class I, Groups C and D. This means that things like the surface temperature of compressors will remain below

the flashpoint of any flammable material likely to be found in Class I, Groups Cand D locations.

All models have heavy-gauge, rigid, braced-steel construction with a durable enamel finish. Interiors have epoxy enamel or ABS plastic construction. Each unit is insulated throughout for energy-efficient operation.

These Lab-Line units will prevent potentially destructive explosions in any facility by meeting the standards established by Underwriters’ Laboratory, Inc., OSHA and National Fire Protection Association for storage of hazardous materials.

Lab-Line Explosion-Proof Refrigerators and Freezers are 100% explosion-proof. They also meet National Fire Protection Standards as found in Articles 500-501 and provide total protection while storing reagents at or below ambient temperatures.

Page 7: OPERATION MANUAL - archive-resources.coleparmer.com · this manual. • Be sure to fill out the Warranty Registration Card and mail it in to Lab-Line Instruments within seven (7)

7

EXPLOSION-PROOFREFRIGERATORS/FREEZERS: (Con’t)

Explosion-proof models are specifically designed and engineered to prevent the triggering of an explosion inside or outside of the unit in a Class I, Groups C and D hazardous material environment.

These models feature stainless steel refrigeration components that are more resistant to attack from corrosive vapors than are aluminum or epoxy-coated aluminum.

It is important to note that Explosion-Proof models must be connected to the power supply source by rigid metal conduit or mineral-insulated cable with proper fittings suitable for Class I, Groups C and D hazardous locations. In addition, the wires inside the conduit must be sealed.

All units carry a 12 month warranty.

Page 8: OPERATION MANUAL - archive-resources.coleparmer.com · this manual. • Be sure to fill out the Warranty Registration Card and mail it in to Lab-Line Instruments within seven (7)

8

EXPLOSION-PROOF UNITS: (Con’t)

MODEL 3551/-123¼” WIDE2-DOORREFRIGERATOR/FREEZER:

FEATURES: • ADJUSTABLE NATURAL AIR FLOW VENT• OVERALL 11 CU. FT. • MANUAL DEFROST• 3 ADJUSTABLE SHELVES • ABS PLASTIC INTERIOR• 4 DOOR SHELVES • WHITE COLOR• HYDRAULIC THERMOSTAT

TOTAL CHAMBER DIMENSIONS VOL. EXTERIOR H” X W” X D” (CM) (CU. DIMENSIONSMODEL REFRIGERATOR FREEZER FT.) H” X W” X D” (CM)

3551 41½”H X 20¾”W X 14”D 12¾”H X 19”W X 15”D 11 63”H X 23¼”W X 24½”D (105 X 53 X 36 cm) (32 X 48 X 38 cm) (160 X 59 X 62 cm)

3551-1 41½”H X 20¾”W X 14”D 12¾”H X 19”W X 15”D 11 63”H X 23¼”W X 24½”D (105 X 53 X 36 cm) (32 X 48 X 38 cm) (160 X 59 X 62 cm)

NET SHIP ELECTRICAL WT. WT. CHARACTERISTICS TEMP. RANGE ºC (ºF) LBS. LBS.MODEL VOLTS/HZ WATTS AMPS REFRIG. FREEZER (KG) (KG)

3551 120/60 360 3.0 0º to 10º -20 to -0º 120 150(32º to 50º) (-4º to 32º) (54.5) (68.2)

3551-1 240/50 360 1.5 0º to 10º -20 to -0º 120 150(32º to 50º) (-4º to 32º) (54.5) (68.2)

NOTE: AMPS LISTED ARE AT NORMAL RUN MODE, STARTING AMPS MAY BE HIGHER.

LAB-LINE RESERVES THE RIGHT TO CHANGE SPECIFICATIONS WITHOUT PRIOR NOTICE.

EXPLOSION-PROOF UNITS: (Con’t)

Page 9: OPERATION MANUAL - archive-resources.coleparmer.com · this manual. • Be sure to fill out the Warranty Registration Card and mail it in to Lab-Line Instruments within seven (7)

9

MODEL 3552/-132” WIDE1-DOORUPRIGHT FREEZER:

FEATURES:• OVERALL 20 CU. FT. • MANUAL DEFROST• BUILT-IN, EVEN-COOLING SHELVES • WHITE COLOR• 4 PERMANENTLY POSITIONED WIRE SHELVES• LOCKING DOOR

TOTAL CHAMBER DIMENSIONS VOL. EXTERIOR H” X W” X D” (CM) (CU. DIMENSIONSMODEL REFRIGERATOR FREEZER FT.) H” X W” X D” (CM)

3552 57”H X 27”W X 18”D 20 71½”H X 32”W X 33”D (149 X 69X 46 cm) (181 X 81 X 84 cm)

3552-1 57”H X 27”W X 18”D 20 71½”H X 32”W X 33”D (149 X 69X 46 cm) (181 X 81 X 84 cm)

NET SHIP ELECTRICAL WT. WT. CHARACTERISTICS TEMP. RANGE ºC (ºF) LBS. LBS.MODEL VOLTS/HZ WATTS AMPS REFRIG. FREEZER (KG) (KG)

3552 120/60 516 4.3 -23º to -5º 225 240 (-9 º to 23º) (102.3) (109.1)

3552-1 240/50 516 2.1 -23º to -5º 225 240 (-9 º to 23º) (102.3) (109.1)

NOTE: AMPS LISTED ARE AT NORMAL RUN MODE, STARTING AMPS MAY BE HIGHER.

LAB-LINE RESERVES THE RIGHT TO CHANGE SPECIFICATIONS WITHOUT PRIOR NOTICE.

EXPLOSION-PROOF UNITS: (Con’t)

MODEL 3555/-1 MODEL 3555-6 MODEL 3555-7

Page 10: OPERATION MANUAL - archive-resources.coleparmer.com · this manual. • Be sure to fill out the Warranty Registration Card and mail it in to Lab-Line Instruments within seven (7)

10

60¼” WIDE 31½” WIDE 31½” WIDECHEST FREEZER: CHEST FREEZER: CHEST FREEZER:

FEATURES: FEATURES: FEATURES:• OVERALL 18 CU. FT. • OVERALL 6.0 CU. FT. • OVERALL 6.0 CU. FT.• KEY LOCK • KEY LOCK • KEY LOCK• STORAGE BASKET • STORAGE BASKET • STORAGE BASKET• KEYLOCK LID • KEYLOCK LID • KEYLOCK LID• MANUAL DEFROST • MANUAL DEFROST • MANUAL DEFROST• WHITE COLOR • WHITE COLOR • WHITE COLOR

EXPLOSION-PROOF UNITS: (Con’t)

TOTAL

CHAMBER DIMENSIONS VOL. EXTERIOR H” X W” X D” (CM) (CU. DIMENSIONS

Page 11: OPERATION MANUAL - archive-resources.coleparmer.com · this manual. • Be sure to fill out the Warranty Registration Card and mail it in to Lab-Line Instruments within seven (7)

11

MODEL REFRIGERATOR FREEZER FT.) H” X W” X D” (CM)

3555 28”H X 50¼”W X 22¼”D 18 35”H X 60¼”W X 29½”D (71X 128 X 57 cm) (89 X 153 X 75 cm)

3555-1 28”H X 50¼”W X 22¼”D 18 35”H X 60¼”W X 29½”D (71X 128 X 57 cm) (89 X 153 X 75 cm)

3555-6 28”H X 26¼”W X 16½”D 6 35”H X 35”W X 26¼”D (71 X 67X 42 cm) (89 X 80X 67 cm)

3555-7 28”H X 26¼”W X 16½”D 6 35”H X 35”W X 26¼”D (71 X 67X 42 cm) (89 X 80X 67 cm)

NET SHIP ELECTRICAL WT. WT. CHARACTERISTICS TEMP. RANGE ºC (ºF) LBS. LBS.MODEL VOLTS/HZ WATTS AMPS REFRIG. FREEZER (KG) (KG)

3555 120/60 516 4.3 -28º to -18º 185 200 (-18º to 0º) (84.1) (90.9)

3555-1 240/50 516 2.1 -28º to -18º 185 200 (-18º to 0º) (84.1) (90.9)

3555-6 120/60 276 2.3 -21º to -4º 95 125 (-5 to 24º) (43) (57)

3555-7 240/50 276 1.1 -21º to -4º 95 125 (-5 to 24º) (43) (57)

NOTE: AMPS LISTED ARE AT NORMAL RUN MODE, STARTING AMPS MAY BE HIGHER.

LAB-LINE RESERVES THE RIGHT TO CHANGE SPECIFICATIONS WITHOUT PRIOR NOTICE.

Page 12: OPERATION MANUAL - archive-resources.coleparmer.com · this manual. • Be sure to fill out the Warranty Registration Card and mail it in to Lab-Line Instruments within seven (7)

12

EXPLOSION-PROOF UNITS: (Con’t)

MODEL 3557 MODEL 3557-2 MODEL 3557-4& 3557-1 & 3557-3 & 3557-5

23-1/3” WIDE, 21¼” WIDE 21¼” WIDEUNDER-COUNTER UNDERCOUNTER UNDERCOUNTERREFRIGERATOR FREEZER: REFRIGERATOR/FREEZER:KEY LOCK:

FEATURES: FEATURES: FEATURES:• COLD-WALL DESIGN • ADJUSTABLE THERMOSTAT • 1-PIECE SEAMLESS INTERIOR• AMPLE DOOR STORAGE • MAGNETIC GASKET • 2 RUSTPROOF, SLIDE-OUT • ADJUSTABLE THERMOSTAT • HERMETICALLY-SEALED SHELVES• REAR ROLLERS COMPRESSOR • ADJUSTABLE FOOT• FRONT LEGS LEVEL-ADJUST • OFF CYCLE DEFROST • DRIP TRAY• MAGNETIC GASKET • WHITE COLOR • MANUAL DEFROST• STURDY METAL HINGES • WHITE COLOR• SEAMLESS 1-PIECE POLYPROPYLENE LINER• WHITE COLOR• 1 GLASS SHELF

3557 NOTE: THIS UNIT IS DESIGNED FOR FREE STANDING INSTALLATION ONLY. IT MAY BEINSTALLED UNDER A COUNTER ONLY IF SUFFICIENT SPACE FOR AIR FLOW IS PROVIDED—IT IS SUGGESTED THE UNIT BE RECESSED ONLY 21” TO PERMIT EASY ACCESS TO THE LOCK.

3557-4 & 3557-5 NOTE: THIS UNIT IS DESIGNED FOR FREE STANDING INSTALLATION ONLY. ITMAY BE ENCLOSED ONLY IF SUFFICIENT SPACE IS PROVIDED FOR PROPER VENTILATION—1” ON THE SIDES, TOP AND REAR , ARE RECOMMENDED.

EXPLOSION-PROOF UNITS: (Con’t)

Page 13: OPERATION MANUAL - archive-resources.coleparmer.com · this manual. • Be sure to fill out the Warranty Registration Card and mail it in to Lab-Line Instruments within seven (7)

13

TOTAL CHAMBER DIMENSIONS VOL. EXTERIOR H” X W” X D” (CM) (CU. DIMENSIONSMODEL REFRIGERATOR FREEZER FT.) H” X W” X D” (CM)

3557 27-½”H X 19”W X 13”D 5.6 33½”H X 23½”W X 23¾”D (70 X 48 X 33 cm) (85 X 59 X 60 cm)

3557 -1 27-½”H X 19”W X 13”D 5.6 33½”H X 23½”W X 23¾”D (70 X 48 X 33 cm) (85 X 59 X 60 cm)

3557-2 27½”Hx18”Wx15”D 5.6 33½”H X 21¼”W X 25¼”D (70 X 46 X 38 cm) (85 X 54 X 64 cm)

3557-3 27½”Hx18”Wx15”D 5.6 33½”H X 21¼”W X 25¼”D (70 X 46 X 38 cm) (85 X 54 X 64 cm)

3557-4 21”HX18”WX15¼”D 5¼”H X 15¼”W X 11”D 5.6 33½H X 21¼”W X 25¼”D (53 X 46 X 39 cm) (13 X 39 X 28 cm) (85 X 54 X 64 cm)

3557-5 21”HX18”WX15¼”D 5¼”H X 15¼”W X 11”D 5.6 33½H X 21¼”W X 25¼”D (53 X 46 X 39 cm) (13 X 39 X 28 cm) (85 X 54 X 64 cm)

NET SHIP ELECTRICAL WT. WT. CHARACTERISTICS TEMP. RANGE ºC (ºF) LBS. LBS.MODEL VOLTS/HZ WATTS AMPS REFRIG. FREEZER (KG) (KG)

3557 120/60 160 1.3 2º to 7º 100 120 (36º to 45º) (45.3) (54.5)

3557-1 240/50 160 0.66 2º to 7º 100 120

(36º to 45º) (45.3) (54.5)

3557-2 120/60 200 1.6 -26º to -15º 100 125 (-15º to 5º) (45.3) (54.5)

3557-3 240/50 200 0.83 -26º to -15º 100 120 (-15º to 5º) (45.3) (54.5)

3557-4 120/60 160 1.3 2º to 7º -26º to -6º 100 120 (36º to 45º) (-15º to 21º) (45.3) (54.5)

3557-5 240/50 160 0.66 2º to 7º -26º to -6º 100 120 (36º to 45º) (-15º to 21º) (45.3) (54.5)

NOTE: AMPS LISTED ARE AT NORMAL RUN MODE, STARTING AMPS MAY BE HIGHER.

LAB-LINE RESERVES THE RIGHT TO CHANGE SPECIFICATIONS WITHOUT PRIOR NOTICE.

EXPLOSION-PROOF UNITS: (Con’t)

Page 14: OPERATION MANUAL - archive-resources.coleparmer.com · this manual. • Be sure to fill out the Warranty Registration Card and mail it in to Lab-Line Instruments within seven (7)

14

MODEL 3559/-123” WIDE, SINGLE-DOORREFRIGERATOR/FREEZER:

FEATURES:• 3 ADJUSTABLE SHELVES• 4 DOOR SHELVES• ADJUSTABLE THERMOSTAT • MANUAL DEFROST• WHITE COLOR

TOTAL CHAMBER DIMENSIONS VOL. EXTERIOR H” X W” X D” (CM) (CU. DIMENSIONSMODEL REFRIGERATOR FREEZER FT.) H” X W” X D” (CM)

3559 32”H X 19¾”W X 17½”D 8”H X 17¼”W X 12”D 10 58”H X 23”W X 23½”D (83X 50X 45 cm) (20 X 44 X 30 cm) (147 X 58 X 60 cm)

3559 -1 32”H X 19¾”W X 17½”D 8”H X 17¼”W X 12”D 10 58”H X 23”W X 23½”D (83X 50X 45 cm) (20 X 44 X 30 cm) (147 X 58 X 60 cm)

NET SHIP ELECTRICAL WT. WT. CHARACTERISTICS TEMP. RANGE ºC (ºF) LBS. LBS.MODEL VOLTS/HZ WATTS AMPS REFRIG. FREEZER (KG) (KG)

3559 120/60 360 3.0 1º to 10º -17º to -6º 120 150 (34º to 50º) (-1º to 21º) (54.5) (68.2)

3559-1 240/50 360 1.5 1º to 10º -17º to -6º 120 150

(34º to 50º) (-1º to 21º) (54.5) (68.2)

NOTE: AMPS LISTED ARE AT NORMAL RUN MODE, STARTING AMPS MAY BE HIGHELAB-LINE RESERVES THE RIGHT TO CHANGE SPECIFICATIONS WITHOUT PRIOR NOTICE.

EXPLOSION-PROOF UNITS: (Con’t)

MODEL 3566/-1:32” WIDE, 1-DOOR, REFRIGERATOR :

Page 15: OPERATION MANUAL - archive-resources.coleparmer.com · this manual. • Be sure to fill out the Warranty Registration Card and mail it in to Lab-Line Instruments within seven (7)

15

FEATURES:• COPPER EVAPORATOR COIL REFRIGERATION COMPONENTS• OVERALL 20 CU. FT.• 5 ADJUSTABLE SHELVES

TOTAL CHAMBER DIMENSIONS VOL. EXTERIOR H” X W” X D” (CM) (CU. DIMENSIONSMODEL REFRIGERATOR FREEZER FT.) H” X W” X D” (CM)

3566 55”H X 27”W X 20”D 20 71½”H X 32”W X 28½”D (140 X 69 X 51 cm) (182 X 81 X 72 cm)

3566-1 55”H X 27”W X 20”D 20 71½”H X 32”W X 28½”D (140 X 69 X 51 cm) (182 X 81 X 72 cm)

NET SHIP ELECTRICAL WT. WT. CHARACTERISTICS TEMP. RANGE ºC (ºF) LBS. LBS.MODEL VOLTS/HZ WATTS AMPS REFRIG. FREEZER (KG) (KG)

3566 120/60 480 4 -5º to 15º 240 280(23º to 9º) (109) (127)

3566-1 240/60 480 2 -5º to 15º 240 280(23º to 9º) (109) (127)

NOTE: AMPS LISTED ARE AT NORMAL RUN MODE, STARTING AMPS MAY BE HIGHERLAB-LINE RESERVES THE RIGHT TO CHANGE SPECIFICATIONS WITHOUT PRIOR NOTICE.

Page 16: OPERATION MANUAL - archive-resources.coleparmer.com · this manual. • Be sure to fill out the Warranty Registration Card and mail it in to Lab-Line Instruments within seven (7)

16

SECTION 3

FLAMMABLE MATERIALSSTORAGE

REFRIGERATORS & FREEZERS

√SHIPPING CARTON:This should be inspected upon delivery. When received, carefully

examine for any shipping damage before unpacking. If damage is discovered, the delivering carrier should both specify and sign for the damage on your copy of the delivery receipt.

Open the carton carefully making certain that all parts are accounted for before packaging materials are discarded—after unpacking, if damage is found promptly report it to the carrier and request a damage inspection promptly.

IMPORTANT: Failure to request an inspection of damage within a few days after receipt of shipment absolves the carrier from any liability for damage: you must call for a damage inspection promptly.

AN OVERVIEW: THE FULL LINE FROM LAB-LINE: FLAMMABLEMATERIAL STORAGE REFRIGERATORS AND FREEZERS.

These Lab-Line units will prevent potentially destructive explosions in any facility by meeting the standards established by Underwriters’ Laboratory, Inc., OSHA and National Fire Protection Association for storage of hazardous materials. They also are designed to comply with National Fire Protection Association Standards Nos. 45 and 99, as well as OSHA Article No. CFR 1910.308. Lab-Line Flammable Materials Storage Refrigerators/Freezers are manufactured for safe, cold storage of volatile materials.

Flammable Material Storage (FMS) Refrigerators/Freezers will prevent an explosion from occurring inside the unit. These units have no internal electrical components which could trigger an explosion of hazardous materials inside the unit. (They are NOT designed for use in Class I, Groups C and D environments—for these locations use a Lab-Line Explosion-Proof Refrigerator.) However, FMS units are not suitable for use in Class I, Group C and D environments.

This complete line includes single and 2-door upright refrigerators and freezers, horizontal chest freezers, and undercounter refrigerators.

FLAMMABLE MATERIALS STORAGE

Page 17: OPERATION MANUAL - archive-resources.coleparmer.com · this manual. • Be sure to fill out the Warranty Registration Card and mail it in to Lab-Line Instruments within seven (7)

17

REFRIGERATORS & FREEZERS: (Con’t)

These units are ideal for storing cyclopropane, ethyl ether, ethylene, acetone, alcohol, benzene, butane, gasoline, hexane, lacquer solvent vapors, naphtha, natural gas or propane along with many other potentially hazardous materials.

All cabinets have heavy-gauge steel construction with a durable exterior finish of epoxy enamel. A well insulated cabinet and tight sealing magnetic door prevent air leaks along with helping to lower operating costs. The interior is madeof porcelain enameled steel or ABS plastic.

Lab-Line offers the largest selection of FMS units. All models are delivered with 3-wire line cord and molded plug. All 120 volt FMS models are UL Listed.

All units carry a 12 month warranty.

FLAMMABLE MATERIAL STORAGE

Page 18: OPERATION MANUAL - archive-resources.coleparmer.com · this manual. • Be sure to fill out the Warranty Registration Card and mail it in to Lab-Line Instruments within seven (7)

18

UNITS:

MODEL 3551-10/-1120¾” WIDE2-DOORREFRIGERATOR/FREEZER:

FEATURES:• OVERALL 11 CU. FT. • MANUAL DEFROST• 4 ADJUSTABLE THERMOSTAT • WHITE COLOR• ABS PLASTIC INTERIOR

NOTE: IN ORDER FOR FREEZER TO REACH -20ºC, VENT ON INSIDE UPPER REAR OFREFRIGERATOR MUST BE CLOSED.

TOTAL CHAMBER DIMENSIONS VOL. EXTERIOR H” X W” X D” (CM) (CU. DIMENSIONSMODEL REFRIGERATOR FREEZER FT.) H” X W” X D” (CM)

3551-10 41½”H X 20¾”W X 14”D 12¾”H X 19”W X 15”D 11 63”H X 23¼”W X 24½”D (105 X 53 X 36 cm) (32 X 48 X 38 cm) (160 X 59 X 62 cm)

3551-11 41½”H X 20¾”W X 14”D 12¾”H X 19”W X 15”D 11 63”H X 23¼”W X 24½”D (105 X 53 X 36 cm) (32 X 48 X 38 cm) (160 X 59 X 62 cm)

NET SHIP ELECTRICAL WT. WT. CHARACTERISTICS TEMP. RANGE ºC (ºF) LBS. LBS.MODEL VOLTS/HZ WATTS AMPS REFRIG. FREEZER (KG) (KG)

3551-10 120/60 360 3.0 0º to 10º -20º to -0º 120 150 (32º to 50º) (-4º to 32º) (54.5) (68.2)

3551-11 240/50 360 1.5 0º to 10º -20º to -0º 120 150 (32º to 50º) (-4º to 32º) (54.5) (68.2)

NOTE: AMPS LISTED ARE AT NORMAL RUN MODE, STARTING AMPS MAY BE HIGHER.

LAB-LINE RESERVES THE RIGHT TO CHANGE SPECIFICATIONS WITHOUT PRIOR NOTICE.

FLAMMABLE MATERIAL STORAGEUNITS:

Page 19: OPERATION MANUAL - archive-resources.coleparmer.com · this manual. • Be sure to fill out the Warranty Registration Card and mail it in to Lab-Line Instruments within seven (7)

19

MODEL 3552-10/1132” WIDE1-DOORUPRIGHT FREEZERS:

FEATURES:• OVERALL 20 CU. FT.• 4 PERMANENT WIRE SHELVES• 6 DOOR SHELVES• ENAMELED STEEL INTERIOR WITH ABS PLASTIC• LOCKING DOOR• MANUAL DEFROST• WHITE COLOR

TOTAL

CHAMBER DIMENSIONS VOL. EXTERIOR H” X W” X D” (CM) (CU. DIMENSIONSMODEL REFRIGERATOR FREEZER FT.) H” X W” X D” (CM)

3552-10 57”H X 27”W X 18”D 20 71½”H X 32”W X 33”D (145 X 69 X 46 cm) (182 X 81 X 84 cm)

3552-11 57”H X 27”W X 18”D 20 71½”H X 32”W X 33”D (145 X 69 X 46 cm) (182 X 81 X 84 cm)

NET SHIP ELECTRICAL WT. WT. CHARACTERISTICS TEMP. RANGE ºC (ºF) LBS. LBS.MODEL VOLTS/HZ WATTS AMPS REFRIG. FREEZER (KG) (KG)

3552-10 120/60 516 4.3 -23º to -5º 225 240 (-9º to 23º) (102.3) (109.1)

3552-11 240/50 516 2.1 -23º to -5º 225 240 (-9º to 23º) (102.3) (109.1)

NOTE: AMPS LISTED ARE AT NORMAL RUN MODE, STARTING AMPS MAY BE HIGHER.

LAB-LINE RESERVES THE RIGHT TO CHANGE SPECIFICATIONS WITHOUT PRIOR NOTICE.

FLAMMABLE MATERIAL STORAGEUNITS:

Page 20: OPERATION MANUAL - archive-resources.coleparmer.com · this manual. • Be sure to fill out the Warranty Registration Card and mail it in to Lab-Line Instruments within seven (7)

20

MODEL 3556(X)/-1MODEL 3556-4 MODEL 3556-6COMPACT 23-3/8” WIDE, 18¼” WIDE 21¼” WIDENO-FROST FRONT-OPENING REFRIGERATOR/FREEZER:UNDERCOUNTER FREEZER: ALL-REFRIGERATORKEY LOCK:

FEATURES: FEATURES: FEATURES:• COLD-WALL DESIGN • ADJUSTABLE THERMOSTAT • 1-PIECE SEAMLESS INTERIOR• AMPLE DOOR STORAGE • MAGNETIC GASKET • 2 RUSTPROOF, SLIDE-OUT • ADJUSTABLE THERMOSTAT • HERMETICALLY-SEALED SHELVES• REAR ROLLERS COMPRESSOR • 3 IN-DOOR RACKS• FRONT LEGS LEVEL-ADJUST • OFF CYCLE DEFROST • ADJUSTABLE FOOT• MAGNETIC GASKET • WHITE COLOR • DRIP TRAY• STURDY METAL HINGES • MANUAL DEFROST• SEAMLESS 1-PIECE • WHITE COLOR POLYPROPYLENE LINER• WHITE COLOR• 1 GLASS SHELF

3556(X)/-1 NOTE: THIS UNIT IS DESIGNED FOR FREE STANDING INSTALLATION ONLY. IT MAY BEINSTALLED UNDER A COUNTER ONLY IF SUFFICIENT SPACE FOR AIR FLOW IS PROVIDED—IT IS SUGGESTED THE UNIT BE RECESSED ONLY 21” TO PERMIT EASY ACCESS TO THE LOCK.

3556-6 NOTE: THIS UNIT IS DESIGNED FOR FREE STANDING INSTALLATION ONLY. IT MAY BEENCLOSED ONLY IF SUFFICIENT SPACE IS PROVIDED FOR PROPER VENTILATION—1” ON THESIDES, TOP AND REAR , ARE RECOMMENDED.

FLAMMABLE MATERIAL STORAGEUNITS: (Con’t)

TOTAL

Page 21: OPERATION MANUAL - archive-resources.coleparmer.com · this manual. • Be sure to fill out the Warranty Registration Card and mail it in to Lab-Line Instruments within seven (7)

21

CHAMBER DIMENSIONS VOL. EXTERIOR H” X W” X D” (CM) (CU. DIMENSIONSMODEL REFRIGERATOR FREEZER FT.) H” X W” X D” (CM)

3556 27½”H X 19”W X 13”D 5.6 33½”H X 23½”W X 23¾”D (70 X 48 X 33 cm) (85 X 59 X 60 cm)

3556-1 27½”H X 19”W X 13”D 5.6 33½”H X 23½”W X 23¾”D (70 X 48 X 33 cm) (85 X 59 X 60 cm)

3556-4 27½”H X 18”W X 15”D 5.6 33½”H X 21¼”W X 25¼”D (70 X 46 X 38 cm) (85 X 54 X 64 cm)

3556-6 21”H X 18”W X 15¼”D 5¼”H X 15¼”W X 11”D 5.6 33½”H X 21¼”W X 25¼”D (53 X 46 X 39 cm) (13 X 39 X 28 cm) (85 X 54 X 64 cm)

NET SHIP ELECTRICAL WT. WT. CHARACTERISTICS TEMP. RANGE ºC (ºF) LBS. LBS.MODEL VOLTS/HZ WATTS AMPS REFRIG. FREEZER (KG) (KG)

3556 120/60 160 1.3 2º to 7º 100 120 (36º to 45º) (45.5) (54.5)

3556-1 240/50 160 .66 2º to 7º 100 120 (36º to 45º) (45.5) (54.5)

3556-4 120/60 200 .60 -26º to 15º 100 120 (15 to 32) (45.5) (54.5)

3556-6 120/60 160 1.3 2º to 7º -26º to -6º 100 120 (36º to 45º) (-15º to 21º) (45.5) (54.5)

NOTE: AMPS LISTED ARE AT NORMAL RUN MODE, STARTING AMPS MAY BE HIGHER.

LAB-LINE RESERVES THE RIGHT TO CHANGE SPECIFICATIONS WITHOUT PRIOR NOTICE.

FLAMMABLE MATERIAL STORAGEUNITS: (Con’t)

MODEL 3559-10/-1124” WIDE, SINGLE-DOORREFRIGERATOR/FREEZER:

Page 22: OPERATION MANUAL - archive-resources.coleparmer.com · this manual. • Be sure to fill out the Warranty Registration Card and mail it in to Lab-Line Instruments within seven (7)

22

FEATURES:• 3 ADJUSTABLE SHELVES• 4 DOOR SHELVES• ADJUSTABLE THERMOSTAT • MANUAL DEFROST• ABS PLASTIC INTERIOR• WHITE COLOR

TOTAL CHAMBER DIMENSIONS VOL. EXTERIOR H” X W” X D” (CM) (CU. DIMENSIONSMODEL REFRIGERATOR FREEZER FT.) H” X W” X D” (CM)

3559-10 32”H X 19¾”W X 17½”D 8”H X 17¼”W X 12”D 10 58”H X 23”W X 23½”D (83 X 50 X 45 cm) (20 X 44 X 31 cm) (147 X 58 X 60 cm)

3559 -11 32”H X 19¾”W X 17½”D 8”H X 17¼”W X 12”D 10 58”H X 23”W X 23½”D 83 X 50 X 45 cm) (20 X 44 X 31 cm) (147 X 58 X 60 cm)

NET SHIP ELECTRICAL WT. WT. CHARACTERISTICS TEMP. RANGE ºC (ºF) LBS. LBS.MODEL VOLTS/HZ WATTS AMPS REFRIG. FREEZER (KG) (KG)

3559-10 120/60 360 3.0 1º to 10º -17º to -6º 120 150 (34º to 50º) (1º to 21.º) (54.5) (68.2)

3559-11 240/50 360 1.5 1º to 10º -17º to -6º 120 150

(33.8º to 50º) (1º to 21º) (54.5) (68.2)

NOTE: AMPS LISTED ARE AT NORMAL RUN MODE, STARTING AMPS MAY BE HIGHER.

LAB-LINE RESERVES THE RIGHT TO CHANGE SPECIFICATIONS WITHOUT PRIOR NOTICE.

FLAMMABLE MATERIAL STORAGEUNITS: (Con’t)

MODEL 3566-10/-11:32” WIDE, 1-DOOR, REFRIGERATOR :

FEATURES:• ALUMINUM EVAPORATOR COIL REFRIGERATION COMPONENTS• OVERALL 20 CU. FT.

Page 23: OPERATION MANUAL - archive-resources.coleparmer.com · this manual. • Be sure to fill out the Warranty Registration Card and mail it in to Lab-Line Instruments within seven (7)

23

• 5 ADJUSTABLE SHELVES TOTAL

CHAMBER DIMENSIONS VOL. EXTERIOR H” X W” X D” (CM) (CU. DIMENSIONSMODEL REFRIGERATOR FREEZER FT.) H” X W” X D” (CM)

3566-10 55”H X 27”W X 20”D 20 71½”H X 32”W X 28½”D (140 X 69 X 51 cm) (182 X 81 X 72 cm)

3566-11 55”H X 27”W X 20”D 20 71½”H X 32”W X 28½”D (140 X 69 X 51 cm) (182 X 81 X 72 cm)

NET SHIP ELECTRICAL WT. WT. CHARACTERISTICS TEMP. RANGE ºC (ºF) LBS. LBS.MODEL VOLTS/HZ WATTS AMPS REFRIG. FREEZER (KG) (KG)

3566-10 120/60 480 4 -5º to 15º 240 280(23º to 9º) (109) (127)

3566-11 240/60 480 2 -5º to 15º 240 280(23º to 9º) (109) (127)

NOTE: AMPS LISTED ARE AT NORMAL RUN MODE, STARTING AMPS MAY BE HIGHERLAB-LINE RESERVES THE RIGHT TO CHANGE SPECIFICATIONS WITHOUT PRIOR NOTICE.

SECTION 4

CORROSION-RESISTANTREFRIGERATORS/FREEZERS

BE ADVISED:DANGER: UNLESS UNIT IS SPECIFICALLY DESIGNED FOR COMBUSTIBLE ORFLAMMABLE ATMOSPHERES, DO NOT USE IN THE PRESENCE OF FLAMMABLE

Page 24: OPERATION MANUAL - archive-resources.coleparmer.com · this manual. • Be sure to fill out the Warranty Registration Card and mail it in to Lab-Line Instruments within seven (7)

24

OR COMBUSTIBLE MATERIALS OR EXPLOSIVE GASES; DO NOT USE IN THEPRESENCE OF PRESSURIZED OR SEALED CONTAINERS—FIRE OR EXPLOSIONMAY RESULT CAUSING DEATH.

WARNING: DO NOT HEAT ANY SUBSTANCE ABOVE A TEMPERATURE THATWILL CAUSE IT TO EMIT TOXIC FUMES—DEATH OR SEVERE INJURY MAYRESULT.

WARNING: BEFORE CONNECTING THE FINAL POWER SUPPLY, CHECK THEELECTRICAL CHARACTERISTICS OF THE UNIT NAMEPLATE TO SEE THAT IT ISIN AGREEMENT WITH THE POWER SUPPLIED. IN ADDITION, POWER SHOULD BEWIRED TO THE UNIT ACCORDING TO THE ELECTRICAL SCHEMATIC AND ALLAPPLICABLE CODES. ONLY QUALIFIED ELECTRICIANS SHOULD WORK ON THEELECTRICAL PORTION OF ANY UNIT INSTALLATION.

CAUTION: SOLUTIONS USED TO CLEAN COILS OR NEUTRALIZE BACTERIAGROWTH MUST NOT BE CORROSIVE TO METALS (ENAMEL-COATED STEEL)AND MATERIALS USED IN THE MAINTENANCE OF THIS EQUIPMENT—DAMAGECAN RESULT: USE A SOFT CLOTH AND WARM WATER TO CLEAN.

Page 25: OPERATION MANUAL - archive-resources.coleparmer.com · this manual. • Be sure to fill out the Warranty Registration Card and mail it in to Lab-Line Instruments within seven (7)

25

CORROSION-RESISTANTREFRIGERATORS/FREEZERS: (Con’t)

√SHIPPING CARTON:This should be inspected upon delivery. When received, carefully

examine for any shipping damage before unpacking. If damage is discovered, the delivering carrier should both specify and sign for the damage on your copy of the delivery receipt.

Open the carton carefully making certain that all parts are accounted for before packaging materials are discarded—after unpacking, if damage is found promptly report it to the carrier and request a damage inspection promptly.

IMPORTANT: Failure to request an inspection of damage within a few days after receipt of shipment absolves the carrier from any liability for damage: you must call for a damage inspection promptly.

AN OVERVIEW: THE FULL LINE FROM LAB-LINE: CORROSION-RESISTANT REFRIGERATORS AND FREEZERS.

Aluminum or epoxy-coated refrigeration components are susceptible to attack by caustic materials and strong acids. These components will corrode, and, as a result, will leak—allowing Freon to escape. This inevitably causes the compressor to fail.

Lab-Line units eliminate these problems by utilizing stainless steel condensing coils, evaporators and shelves.

Units come 5 shelves (depending on model) which are adjustable on 1” centers, along with a storage basket. Units can be utilized either as a freezer or refrigerator. They can include porcelain enamel interior and stainless steel door liners for improved corrosion resistance over ABS plastic or enameled steel. A locking door is standard.

Both explosion-proof and flammable material storage versions are available.

All units carry a 12 month warranty.

CORROSION-RESISTANT UNITS:

Page 26: OPERATION MANUAL - archive-resources.coleparmer.com · this manual. • Be sure to fill out the Warranty Registration Card and mail it in to Lab-Line Instruments within seven (7)

26

MODEL 3560/-1/-10/-11:32” WIDE, 1-DOOR, REFRIGERATOR :

FEATURES:• ALUMINUM OR EPOXY COATED • PORCELAIN ENAMEL INTERIOR REFRIGERATION COMPONENTS • STAINLESS STEEL DOOR LINER OVER ABS PLASTIC OR• OVERALL 20 CU. FT. ENAMELED STEEL• 6 ADJUSTABLE SHELVES (ON 1” • KEY LOCK CENTERS) • WHITE COLOR• MANUAL DEFROST

TOTAL CHAMBER DIMENSIONS VOL. EXTERIOR H” X W” X D” (CM) (CU. DIMENSIONSMODEL REFRIGERATOR FREEZER FT.) H” X W” X D” (CM)

3560 55”H X 27”W X 20”D 20 71½”H X 32”W X 28½”D (140 X 69 X 51 cm) (182 X 81 X 72 cm)

3560-1 55”H X 27”W X 20”D 20 71½”H X 32”W X 28½”D (140 X 69 X 51 cm) (182 X 81 X 72 cm)

3560-10 55”H X 27”W X 20”D 20 71½”H X 32”W X 28½”D (140 X 69 X 51 cm) (182 X 81 X 72 cm)

3560-11 55”H X 27”W X 20”D 20 71½”H X 32”W X 28½”D (140 X 69 X 51 cm) (182 X 81 X 72 cm)

NET SHIP ELECTRICAL WT. WT. CHARACTERISTICS TEMP. RANGE ºC (ºF) LBS. LBS.MODEL VOLTS/HZ WATTS AMPS REFRIG. FREEZER (KG) (KG)

3560 120/60 480 4 -5º to 15º 240 280(23º to 9º) (109.1) (127.3)

3560-1 240/60 480 2 -5º to 15º 240 280(23º to 9º) (109.1) (127.3)

3560-10 120/60 480 4 -5º to 15º 240 280(23º to 9º) (109.1) (127.3)

3560-11 240/50 480 2 -5º to 15º 240 280(23º to 9º) (109.1) (127.3)

NOTE: AMPS LISTED ARE AT NORMAL RUN MODE, STARTING AMPS MAY BE HIGHERLAB-LINE RESERVES THE RIGHT TO CHANGE SPECIFICATIONS WITHOUT PRIOR NOTICE.

Page 27: OPERATION MANUAL - archive-resources.coleparmer.com · this manual. • Be sure to fill out the Warranty Registration Card and mail it in to Lab-Line Instruments within seven (7)

27

SECTION 5

GENERAL-PURPOSELABORATORY

REFRIGERATORS/FREEZERS

BE ADVISED:DANGER: UNLESS UNIT IS SPECIFICALLY DESIGNED FOR COMBUSTIBLE ORFLAMMABLE ATMOSPHERES, DO NOT USE IN THE PRESENCE OF FLAMMABLEOR COMBUSTIBLE MATERIALS OR EXPLOSIVE GASES; DO NOT USE IN THEPRESENCE OF PRESSURIZED OR SEALED CONTAINERS—FIRE OR EXPLOSIONMAY RESULT CAUSING DEATH.

WARNING: DO NOT HEAT ANY SUBSTANCE ABOVE A TEMPERATURE THATWILL CAUSE IT TO EMIT TOXIC FUMES—DEATH OR SEVERE INJURY MAYRESULT.

WARNING: BEFORE CONNECTING THE FINAL POWER SUPPLY, CHECK THEELECTRICAL CHARACTERISTICS OF THE UNIT NAMEPLATE TO SEE THAT IT ISIN AGREEMENT WITH THE POWER SUPPLIED. IN ADDITION, POWER SHOULD BEWIRED TO THE UNIT ACCORDING TO THE ELECTRICAL SCHEMATIC AND ALLAPPLICABLE CODES. ONLY QUALIFIED ELECTRICIANS SHOULD WORK ON THEELECTRICAL PORTION OF ANY UNIT INSTALLATION.

CAUTION: SOLUTIONS USED TO CLEAN COILS OR NEUTRALIZE BACTERIAGROWTH MUST NOT BE CORROSIVE TO METALS (ENAMEL-COATED STEEL)AND MATERIALS USED IN THE MAINTENANCE OF THIS EQUIPMENT—DAMAGECAN RESULT: USE A SOFT CLOTH AND WARM WATER TO CLEAN.

Page 28: OPERATION MANUAL - archive-resources.coleparmer.com · this manual. • Be sure to fill out the Warranty Registration Card and mail it in to Lab-Line Instruments within seven (7)

28

GENERAL-PURPOSE LABORATORYREFRIGERATORS/FREEZERS: (Con’t)

√SHIPPING CARTON:This should be inspected upon delivery. When received, carefully

examine for any shipping damage before unpacking. If damage is discovered, the delivering carrier should both specify and sign for the damage on your copy of the delivery receipt.

Open the carton carefully making certain that all parts are accounted for before packaging materials are discarded—after unpacking, if damage is found promptly report it to the carrier and request a damage inspection promptly.

IMPORTANT: Failure to request an inspection of damage within a few days after receipt of shipment absolves the carrier from any liability for damage: you must call for a damage inspection promptly.

AN OVERVIEW: THE FULL LINE FROM LAB-LINE: GENERAL-PURPOSELABORATORY COOL-LAB® ALL-REFRIGERATORS, REFRIGERATOR/FREEZER AND ALL-FREEZER MODELS.

There are undercounter, upright, along with one- and two-door model refrigerators. All-freezer units features chest, upright and undercounter models.

Features can include white, textured steel cabinet, seamless ABS plastic liner, magnetic door latch(s), polyurethane insulation, rust-proof shelving. Depending upon the model required, additional features are available.

“X” MODEL: OPTIONAL THERMOMETER/TEMPERATURE ALARMModes designated with an “X” come with a fully digital thermometer/

temperature alarm.Though factory-calibrated the unit can be recalibrate, set every function

with a common blunt-point pencil or ballpoint pen.Operation: Thermometer: Temperature range -58º to +230ºF, or -40ºC to

+ 110ºC, with an accuracy to ±2ºF or 1ºC. Continuous temperature readout to 1 degree;

Alarm Mode: Siren alarm and blinking LED warn when temperature passes pre-set critical points for more than 15 minutes.

Power-Failure Alarm: LED display goes out and siren sounds for a minimum of 12 hours.

Pre-Set Delay: 15-minute delay prevents siren sounding during normal door operation or system cycling.

Specifications: Power supply is 110-115V AC external transformer.

Page 29: OPERATION MANUAL - archive-resources.coleparmer.com · this manual. • Be sure to fill out the Warranty Registration Card and mail it in to Lab-Line Instruments within seven (7)

29

COOL-LAB®

GENERAL-PURPOSE LABORATORYUNITS: (Con’t)

MODEL 3750/-1/-2 MODEL 3751(R27)/-1, 3571B18¾” WIDE 23-3/8” WIDE REFRIGERATOR/FREEZER: UNDER-COUNTER

FREEZER:

FEATURES: FEATURES:• 1-PIECE SEAMLESS INTERIOR • ABS PLASTIC INTERIOR • 2 RUSTPROOF, SLIDE OUT • 4 ADJUST-SHELVES SHELVES • ADJUSTABLE THERMOSTAT• 3 IN-DOOR SHELVES • MAGNETIC DOOR GASKET• ADJUSTABLE FOOT • WHITE COLOR• DRIP TRAY • KEY LOCK• MANUAL DEFROST • 1 GLASS SHELF• WHITE COLOR

3750 & 3571 NOTE: THIS UNIT IS DESIGNED FOR FREE STANDING INSTALLATION ONLY. IT MAYBE INSTALLED UNDER A COUNTER ONLY IF SUFFICIENT SPACE FOR AIR FLOW IS PROVIDED.

LAB-LINE RESERVES THE RIGHT TO CHANGE SPECIFICATIONS WITHOUT PRIOR NOTICE.

COOL-LAB®

Page 30: OPERATION MANUAL - archive-resources.coleparmer.com · this manual. • Be sure to fill out the Warranty Registration Card and mail it in to Lab-Line Instruments within seven (7)

30

GENERAL-PURPOSE LABORATORYUNITS: (Con’t)

TOTAL CHAMBER DIMENSIONS VOL. EXTERIOR H” X W” X D” (CM) (CU. DIMENSIONSMODEL REFRIGERATOR FREEZER FT.) H” X W” X D” (CM)

3750 21”H X 18”W X 15¼”D 5¼”H X 15¼”W X 11”D 5.6 33½”HX 21¼”W X 25¼”D (53 X 46 X 39 cm) (13 X 39 X 28 cm) (85 X 54 X 64 cm)

3750-1 21”H X 18”W X 15¼”D 5¼”H X 15¼”W X 11”D 5.6 33½”HX23-1/3”WX23-3/4”D

(53 X 46 X 39 cm) (13 X 39 X 28 cm) (85 X 59 X 60 cm)

3750-2 23½”H X 18¾”W X 20”D 5½”H X 15-3/8”W X 11”D 5.5 33”H X 21¼”W X 26”D (59.6 X 47.6 X 50.8 cm) (13.9 X 39.1 X 27.9 cm) (83.8 X 53.9 X 66.0 cm)

3751 27½”H X19”W X 13”D 5.6 33-1/3”H X 23-1/3”W X 23¾”D (70 X 48 X 33 cm) (85 X 59 X 60 cm)

3751-1 27½”H X19”W X 13”D 5.6 33-1/3”H X 23-1/3”W X 23¾”D

(70 X 48 X 33 cm) (85 X 59 X 60 cm)

NET SHIP ELECTRICAL WT. WT. CHARACTERISTICS TEMP. RANGE ºC (ºF) LBS. LBS.MODEL VOLTS/HZ WATTS AMPS REFRIG. FREEZER (KG) (KG)

3750 120/60 160 1.3 2º to 7º -26º to -6º 100 120 (36º to 45º) (-15º to 21.2º) (45.3) (54.5)

3750-1 240/50 160 0.66 2º to 7º -26º to -6º 100 120 (36º to 45º) (-15º to 21.2º) (45.3) (54.5)

3750-2 240/60 160 0.66 2º to 7º -26º to -6º 100 120 (36º to 45º) (-15º to 21.2º) (45.3) (54.5)

3751 120/60 160 1.3 2º to 7º 100 120 (36º to 45º) (45.5) (54.5)

3751-1 240/50 200 0.8 2º to 7º 100 120 (36º to 45º) (45.5) (54.5)

NOTE: AMPS LISTED ARE AT NORMAL RUN MODE, STARTING AMPS MAY BE HIGHER.

LAB-LINE RESERVES THE RIGHT TO CHANGE SPECIFICATIONS WITHOUT PRIOR NOTICE.

COOL-LAB®

GENERAL-PURPOSE LABORATORY

Page 31: OPERATION MANUAL - archive-resources.coleparmer.com · this manual. • Be sure to fill out the Warranty Registration Card and mail it in to Lab-Line Instruments within seven (7)

31

UNITS: (Con’t)

MODEL 3752/-2 21¼” WIDE UNDER-COUNTERFREEZER:

FEATURES:• ADJUSTABLE THERMOSTAT• MAGNETIC GASKET • HERMETICALLY-SEALED COMPRESSOR• MANUAL DEFROST• WHITE COLOR

TOTAL CHAMBER DIMENSIONS VOL. EXTERIOR H” X W” X D” (CM) (CU. DIMENSIONSMODEL REFRIGERATOR FREEZER FT.) H” X W” X D” (CM)

3752 27½”H X 18”W X 15”D 5.6 33½”H X 21¼”W X 25¼”D (70 X 46 X 38 cm) (85 X 54 X 64 cm)

3752-2 27½”H X 18”W X 15”D 5.6 33½”H X 21¼”W X 25¼”D (70 X 46 X 38 cm) (85 X 54 X 64 cm)

NET SHIP ELECTRICAL WT. WT. CHARACTERISTICS TEMP. RANGE ºC (ºF) LBS. LBS.MODEL VOLTS/HZ WATTS AMPS REFRIG. FREEZER (KG) (KG)

3752 120/60 200 1.6 -26º to -15º 100 120 (-15º to 5º) (45.5) (54.5)

3752-2 240/50 200 0.8 -26º to -15º 100 120 (-15º to 5º) (45.5) (54.5)

NOTE: AMPS LISTED ARE AT NORMAL RUN MODE, STARTING AMPS MAY BE HIGHER.

LAB-LINE RESERVES THE RIGHT TO CHANGE SPECIFICATIONS WITHOUT PRIOR NOTICE.

COOL-LAB®

GENERAL-PURPOSE LABORATORYUNITS: (Con’t)

Page 32: OPERATION MANUAL - archive-resources.coleparmer.com · this manual. • Be sure to fill out the Warranty Registration Card and mail it in to Lab-Line Instruments within seven (7)

32

MODEL 3761/-1 MODEL 3762/-131½” WIDE 60¼” WIDETOP-OPENING TOP-OPENINGCHEST FREEZER: CHEST FREEZER:

FEATURES: FEATURES:• KEY LOCKING COVER • KEY LOCKING COVER • STORAGE BASKET • STORAGE BASKET• KEYLOCK LID • KEYLOCK LID• MANUAL DEFROST • MANUAL DEFROST• WHITE COLOR • WHITE COLOR

COOL-LAB®

GENERAL-PURPOSE LABORATORYUNITS: (Con’t)

TOTAL CHAMBER DIMENSIONS VOL. EXTERIOR H” X W” X D” (CM) (CU. DIMENSIONS

Page 33: OPERATION MANUAL - archive-resources.coleparmer.com · this manual. • Be sure to fill out the Warranty Registration Card and mail it in to Lab-Line Instruments within seven (7)

33

MODEL REFRIGERATOR FREEZER FT.) H” X W” X D” (CM)

3761 28”H X 26¼”W X 16½”D 6.0 35”H X 31½”W X 24¼”D (71 X 67 X 42 cm) (89 X 80X 67 cm)

3761-1 28”H X 26¼”W X 16½”D 6.0 35”H X 31½”W X 24¼”D (71 X 67 X 42 cm) (89 X 80X 67 cm)

3762 28”H X 50¼”W X 22¼”D 18.0 35”H X 60¼”W X 29½”D (71 X 128 X 57 cm) (89 X 153 X 75 cm)

3762-1 28”H X 50¼”W X 22¼”D 18.0 35”H X 60¼”W X 29½”D (71 X 128 X 57 cm) (89 X 153 X 75 cm)

NET SHIP ELECTRICAL WT. WT. CHARACTERISTICS TEMP. RANGE ºC (ºF) LBS. LBS.MODEL VOLTS/HZ WATTS AMPS REFRIG. FREEZER (KG) (KG)

3761 120/60 276 1.5 -21º to -4º 95 125(-5º to 24º) (43.2) (56.8)

3761-1 240/50 276 0.9 -21º to -4º 95 125(-5º to 24º) ((43.2) (56.8)

3762 120/60 516 4.3 -28º to -18º 185 200 (-18º to 0º) (84.1) (90.9)

3762-1 240/50 516 2.1 -28º to -18º 185 200 (-18º to 0º) (84.1) (90.9)

NOTE: AMPS LISTED ARE AT NORMAL RUN MODE, STARTING AMPS MAY BE HIGHER.

LAB-LINE RESERVES THE RIGHT TO CHANGE SPECIFICATIONS WITHOUT PRIOR NOTICE.

COOL-LAB®

GENERAL-PURPOSE LABORATORYUNITS: (Con’t)

MODELS 3763, 3763B 3763BXK, 3763-1 MODEL 3764/-128” WIDE 23” WIDE2-DOOR SINGLE-DOOR

Page 34: OPERATION MANUAL - archive-resources.coleparmer.com · this manual. • Be sure to fill out the Warranty Registration Card and mail it in to Lab-Line Instruments within seven (7)

34

REFRIGERATOR/FREEZER: REFRIGERATOR/FREEZER:

FEATURES: FEATURES:• 2 DOOR SHELVES • 3 ADJUSTABLE SHELVES • ADJUSTABLE THERMOSTAT • MANUAL DEFROST• MAGNETIC DOOR GASKET • WHITE COLOR• AUTOMATIC DEFROST• WHITE COLOR

3763B: OPTIONAL THERMOMETER/TEMPERATURE ALARMModes designated with an “B” come with a fully digital thermometer/

temperature alarm.Though factory-calibrated the unit can be recalibrated with every function

being set with a common blunt-point pencil or ballpoint pen.Operation: Thermometer: Temperature range -58º to +230ºF, or -40ºC to + 110ºC, with an accuracy to ±2ºF or 1ºC. Continuous temperature readout to 1 degree;

Alarm Mode: Siren alarm and blinking LED warn when temperature passes pre-set critical points for more than 15 minutes.

Power-Failure Alarm: LED display goes out and siren sounds for a minimum of 12 hours.

Pre-Set Delay: 15-minute delay prevents siren sounding during normal door operation or system cycling.

Specifications: Power supply is 110-115V AC external transformer.

3763BXK: DUAL THERMOMETER/TEMPERATURE ALARM WITH DUAL KEY LOCKS

This unit is similar to the one above except it offers a separate key lock and temperature alarm with probe for both the refrigerator and freezer section.

COOL-LAB®

GENERAL-PURPOSE LABORATORYUNITS: (Con’t)

TOTAL CHAMBER DIMENSIONS VOL. EXTERIOR H” X W” X D” (CM) (CU. DIMENSIONSMODEL REFRIGERATOR FREEZER FT.) H” X W” X D” (CM)

3763 36½”H X 25”W X 15½”D 15¼”H X 24”W X 16”D 14.0 61½”H X 28”W X 28”D (93 X 64 X 39 cm) (39X 61 X 41 cm) (156 X 71 X 71 cm)

Page 35: OPERATION MANUAL - archive-resources.coleparmer.com · this manual. • Be sure to fill out the Warranty Registration Card and mail it in to Lab-Line Instruments within seven (7)

35

3763-1 36½”H X 25”W X 15½”D 15¼”H X 24”W X 16”D 14.0 61½”H X 28”W X 28”D (93 X 64 X 39 cm) (39X 61 X 41 cm) (156 X 71 X 71 cm)

3764 32”H X 19¾”W X 17½”D 8”H X 17¼”W X 12”D 10.0 58”H X 23”W X 23½”D (81 X 50 X 45 cm) (20 X 44 X 31 cm) (147 X 58 X 60 cm)

3764-1 32”H X 19¾”W X 17½”D 8”H X 17¼”W X 12”D 10.0 58”H X 23”W X 23½”D (81 X 50 X 45 cm) (20 X 44 X 31 cm) (147 X 58 X 60 cm)

NET SHIP ELECTRICAL WT. WT. CHARACTERISTICS TEMP. RANGE ºC (ºF) LBS. LBS.MODEL VOLTS/HZ WATTS AMPS REFRIG. FREEZER (KG) (KG)

3763 120/60 420 3.5 0º to 10º -20º to 0º 170 190 (32º to 50º) (-4º to 32º) (77.3) (86.4)

3763-1 240/50 420 1.7 0º to 10º -20º to 0º 170 190 (32º to 50º) (-4º to 32º) (77.3) (86.4)

3764 120/60 360 3.0 1º to 10º -17º to -6º 120 150 (34º to 50º) (-1º to 21 º) (54.5) (68.24)

3764-1 240/50 360 1.5 1º to 10º -17º to -6º 120 150 (34º to 50º) (-1º to 21 º) (54.5) (68.24)

NOTE: AMPS LISTED ARE AT NORMAL RUN MODE, STARTING AMPS MAY BE HIGHER.

LAB-LINE RESERVES THE RIGHT TO CHANGE SPECIFICATIONS WITHOUT PRIOR NOTICE.

COOL-LAB®

GENERAL-PURPOSE LABORATORYUNITS: (Con’t)

MODEL 3766/-1 MODEL 3767/-1 MODEL 377032” WIDE 32” WIDE 18½” WIDE1-DOOR UPRIGHT BENCH TOPALL-REFRIGERATOR: FREEZER: REFRIGERATOR/FREEZER:

FEATURES: FEATURES: FEATURES: • OVERALL 20 CU. FT. • OVERALL 20 CU. FT. • OVERALL 1.9 CU. FT.• FROST-FREE • 6 DOOR SHELVES • REMOVABLE SHELF• 5 ADJUSTABLE SHELVES • ENAMELED STEEL INTERIOR • MANUAL DEFROST ON 1” CENTERS • KEY LOCK • WHITE COLOR

Page 36: OPERATION MANUAL - archive-resources.coleparmer.com · this manual. • Be sure to fill out the Warranty Registration Card and mail it in to Lab-Line Instruments within seven (7)

36

• 1 STORAGE BASKET • MANUAL DEFROST• ADJUSTABLE THERMOSTAT • WHITE COLOR• AUTOMATIC DEFROST• WHITE COLOR

3770 NOTE: ALLOW THE FOLLOWING CLEARANCE: TOP, 12"; BACK, 5"; SIDES, ½".

GENERAL-PURPOSE LABORATORYUNITS: (Con’t)

TOTAL CHAMBER DIMENSIONS VOL. EXTERIOR H” X W” X D” (CM) (CU. DIMENSIONSMODEL REFRIGERATOR FREEZER FT.) H” X W” X D” (CM)

3766 57”H X 27”W X 17¾”D 20 71”H X 32”W X 28½”D (145 X 69 X 45 cm) (180 X 81 X 72 cm)

3766-1 57”H X 27”W X 17¾”D 20 71”H X 32”W X 28½”D (145 X 69 X 45 cm) (180 X 81 X 72 cm)

3767 57”H X 27”W X 18”D 20 71½”H X 32”W X 33”D (145 X 69 X 46 cm) (182 X 81 X 84 cm)

3767-1 57”H X 27”W X 18”D 20 71½”H X 32”W X 33”D (145 X 69 X 46 cm) (182 X 81 X 84 cm)

3770 15¼”H X 16¼”W X 11”D 6”H X 6¼”W X 8¼”D 1.9 19”H X 18½”W X 19”D (39 X 41 X 28 cm) (15 X 16 X 21 cm) (48 X 47 X 48 cm)

Page 37: OPERATION MANUAL - archive-resources.coleparmer.com · this manual. • Be sure to fill out the Warranty Registration Card and mail it in to Lab-Line Instruments within seven (7)

37

NET SHIP ELECTRICAL WT. WT. CHARACTERISTICS TEMP. RANGE ºC (ºF) LBS. LBS.MODEL VOLTS/HZ WATTS AMPS REFRIG. FREEZER (KG) (KG)

3766 120/60 480 4.0 -5º to 15º 241 285 (23º to 59º) (109.5) (129.5)

3766-1 240/50 480 2.0 -5º to 15º 241 285 (23º to 59º) (109.5) (129.5)

3767 120/60 516 4.3 -23º to -5º 225 240 (-9º to 23º) (102.3) (109.1)

3767-1 240/50 516 2.1 -23º to -5º 225 240 (-9º to 23º) (102.3) (109.1)

3770 120/60 132 1.1 0º to 7º -5º to 0º 46 52(32º to 45º) (23º to 32º) (20.9) (23.6)

NOTE: AMPS LISTED ARE AT NORMAL RUN MODE, STARTING AMPS MAY BE HIGHER.

LAB-LINE RESERVES THE RIGHT TO CHANGE SPECIFICATIONS WITHOUT PRIOR NOTICE.

SECTION 6

INSTALLATION

√SHIPPING CARTON:This should be inspected upon delivery. When received, carefully

examine for any shipping damage before unpacking. If damage is discovered, the delivering carrier should both specify and sign for the damage on your copy of the delivery receipt.

Open the carton carefully making certain that all parts are accounted for before packaging materials are discarded—after unpacking, if damage is found promptly report it to the carrier and request a damage inspection promptly.

IMPORTANT: Failure to request an inspection of damage within a few days after receipt of shipment absolves the carrier from any liability for damage: you must call for a damage inspection promptly.

LOCATIONLocate your unit in the most convenient place and near a grounded electric

outlet. If units are placed on a countertop, the front should be 3" or more back from the edge to avoid accidental tipping of the unit.

If possible, locate your unit out of direct sunlight and away from heatsources such as a radiator, stove or heat duct.

Page 38: OPERATION MANUAL - archive-resources.coleparmer.com · this manual. • Be sure to fill out the Warranty Registration Card and mail it in to Lab-Line Instruments within seven (7)

38

CLEARANCE:Position the unit so that there is at least 12” clearance on the top, 3” at the

back, and 2” on each side. It is recommended that even more space be left at the back of the unit in case maintenance is required.

ELECTRICALUnits must be connected to a grounded outlet matching the nameplate.If you are not sure about the outlet, you should contact a qualified

electrician for assistance.The unit should always be connected to its own individual outlet.

CAUTION: DO NOT REMOVE, UNDER ANY CIRCUMSTANCE, THE GROUNDING PRONGSFROM THE 3-PRONG POWER CORD SUPPLIED WITH ALL UNITS.CAUTION: DO NOT USE ELECTRICAL EXTENSION CORDS WHICH MAY RESULT IN VOLTAGE LOSS AND POSSIBLE HAZARDOUS OPERATION.NOTE: EXPLOSION-PROOF UNITS DO NOT COME WITH LINE CORDS ,THEY REQUIRE RIGID CONDUIT TO BE RUN DIRECTLY IN ORDER TO SEAL OFF THE FITTING ON THERMOSTAT HOUSING. THIS SHOULD BE DONE BY A LICENSED ELECTRICIAN FOLLOWING ALL LOCAL ELECTRICAL CODES. IF ANY QUESTION PERTAINING TO ELECTRICAL SAFETY ARISES, PLEASE REFER TO ARTICLE 501 OF THE NATIONAL ELECTRIC CODE.

Page 39: OPERATION MANUAL - archive-resources.coleparmer.com · this manual. • Be sure to fill out the Warranty Registration Card and mail it in to Lab-Line Instruments within seven (7)

39

INSTALLATION: (Con’t)

HOW TO SEAL KILLARK® BOX CONDUIT WITH FIBER AND SEALING COMPOUNDTO HELP PROTECT AGAINST EXPLOSIONS:

The purpose of the procedure that follows to build fiber rope dams on the left and right hubs of the horizontal conduit. The fiber rope damns will surround conduit wiring that is housed inside the horizontal conduit.

When both the left and right fiber rope dams have been pressed into place, sealing compound is poured between the two and forms into an air-tight plug.

All of this is done in order to prevent the very real threat of gas entering the Killark box and a resulting serious explosion.

After the unit wires have been pulled through the horizontal conduit the following procedure is required:

• Turn power off at the circuit breaker before proceeding.

• Place a small amount of sealing compound granules (enclosed) into aclean mixing vessel. Add small amounts of water while stirring until a thickpaste is formed, then carefully continue adding smaller amounts of wateruntil a thick gravy consistency is achieved—NOT WATERY. (Discard anymaterial that becomes too stiff to use. Never attempt to restore workabilityby stirring in more water.)

• Locate silver Killark box, back/top-center of unit.

CONDUIT DOMED-COVER

UNSCREW & REMOVE COVERCONDUIT OPENING

HORIZONTAL CONDUIT

LEFT RIGHT HUB HUB

• Unscrew conduit domed-cover.

INSTALLATION: (Con’t)

Page 40: OPERATION MANUAL - archive-resources.coleparmer.com · this manual. • Be sure to fill out the Warranty Registration Card and mail it in to Lab-Line Instruments within seven (7)

40

HOW TO SEAL KILLARK® BOX CONDUIT WITH FIBER AND SEALING COMPOUNDTO HELP PROTECT AGAINST EXPLOSIONS: (Con’t)

HORIZONTAL CONDUIT, CUTAWAY:

WIRING

LEFT HUB RIGHT HUB

• Insert fiber rope material down into horizontal conduit opening. Pressingdown firmly, work the material into the left hub and—most importantly—being sure the material COMPLETELY SURROUNDS THE WIRING, fromthe top to the bottom, completely blocking this end of the horizontalconduit.

• Insert fiber rope material down into horizontal conduit opening. Pressingdown firmly, work the material into the right hub and—most importantly—being sure the material COMPLETELY SURROUNDS THE WIRING, fromthe top to the bottom, completely blocking this end of the horizontalconduit.

INSTALLATION: (Con’t)

Page 41: OPERATION MANUAL - archive-resources.coleparmer.com · this manual. • Be sure to fill out the Warranty Registration Card and mail it in to Lab-Line Instruments within seven (7)

41

HOW TO SEAL KILLARK® BOX CONDUIT WITH FIBER AND SEALING COMPOUNDTO HELP PROTECT AGAINST EXPLOSIONS: (Con’t)

• Pour sealing compound down in between the two fiber rope dams fillingthe remaining space—pour slowly, being careful not to trap air bubbles.(Immediately wipe off any spilled sealing compound.)

• Screw conduit domed-cover back onto conduit opening. NOTE: INITIAL SETUP OF SEALING COMPOUND WILL OCCUR IN APPROXIMATELY 30

MINUTE—HOWEVER, THE SEALING COMPOUND REQUIRES A MINIMUM OF 8HOURS ABOVE 32ºF TO DEVELOP SUFFICIENT STRENGTH TO WITHSTANDEXPLOSIONS.

SECTION 7

OPERATION

Page 42: OPERATION MANUAL - archive-resources.coleparmer.com · this manual. • Be sure to fill out the Warranty Registration Card and mail it in to Lab-Line Instruments within seven (7)

42

DANGER: DO NOT USE IN THE PRESENCE OF FLAMMABLE OF COMBUSTIBLE MATERIALS OR EXPLOSIVE GASES. FIRE OR EXPLOSION MAY RESULT, CAUSING DEATH OR SEVERE INJURY.

CHILD ENTRAPMENT WARNING

DANGER: RISK OF CHILD ENTRAPMENT! Before you discard your old refrigerator or freezer:

• Remove door(s),

• Leave the shelves in place so that children may not easily climb inside.

UNIT’S ENVIRONMENTAL OPERATING CONDITIONS:POLLUTION DEGREE: 2

INSTALLATION CATEGORY: IIALTITUDE: 2000 Meters MSL (Mean Sea Level)HUMIDITY: 80% maximum, non-condensing

ELECTRICAL SUPPLY: 120VAC or 240VACVOLTAGE TOLERANCE: ±10% of normal rated line

TEMPERATURE: 15ºC to 40ºCPRODUCT USAGE: This product is intended for use indoors only

START-UP PROCEDURE:Rotate the control knob clockwise to lower the temperature and

counterclockwise raise it.To check chamber temperature, place a dial thermometer on a shelf in

the unit. Initially, rotate the temperature control knob to an arbitrary setting. Allow approximately 2 hours for the temperature to initially stabilize. Check the temperature and compare with the dial setting.

Adjust dial further to reach the desired operating temperature. Alwaysallow ½ to 1 hour for the chamber temperature to stabilize.

Because the markings on the dial do not indicate specific temperatures,use them as reference points for any future setting of the temperature.

If the room thermostat is turned below 60ºF at night, you may want to set the temperature control one step colder. It should be left at this setting for the night time period: return temperature control to original setting when the room thermostat is returned to its normal setting.

RESTART PROCEDURE:If unit is unplugged or turned off, allow 3 minutes before restarting

or plugging it back in.

OPERATION: (Con’t)

MANUAL DEFROST PROCEDURE: FOR MODELS 3556-4, 3556-6, 3557-2, 3557-43750 & 3752 ONLY

Do not use any sharp instrument, blade or scraper to remove ice and

Page 43: OPERATION MANUAL - archive-resources.coleparmer.com · this manual. • Be sure to fill out the Warranty Registration Card and mail it in to Lab-Line Instruments within seven (7)

43

frost on refrigerator surfaces because of the very real danger of puncturing the cooling coil.

Do not use any electrical device to defrost the unit.When frost accumulates to ¼" or more, the operating efficiency of

the unit will be affected. Use the following procedure to defrost manually:

• Turn the temperature control knob to the OFF setting. • Disconnect the power cord from its outlet. • Remove contents of unit. If practical, wrap contents in paper and then in a

heavy blanket to maintain temperature of items, especially those removedfrom a freezer. Wear protective gloves to prevent frost bite when handlingcold items.

• Open door and allow free circulation of ambient air. • To speed the process, place pan of warm water inside the chamber. • Wipe out the interior. • Replace contents. • Reconnect power cord to outlet and set temperature control to desired

operating temperature.

HOW TO SAVE ENERGY:

• Be sure to follow location suggestions as mentioned in the previousINSTALLATION section.

• Wipe moisture from glassware or other materials before placing them in a

unit. • Don't overcrowd the unit—too many items can increase electrical energy

demand in order to keep everything cool. • Close the door as soon as possible in hot, humid weather. • Make certain that the door is closed tightly. • As soon as frost has accumulated to ¼”, defrost. • Keep containers covered (when possible) to reduce moisture buildup. • Set operating temperature—no colder than necessary—for the items

being refrigerated.

OPERATION: (Con’t)

SAFETY TIPS:

Page 44: OPERATION MANUAL - archive-resources.coleparmer.com · this manual. • Be sure to fill out the Warranty Registration Card and mail it in to Lab-Line Instruments within seven (7)

44

• After a unit is in operation, do not touch the cold surfaces, particularlywhen hands are damp—skin may adhere to the extremely cold surfaces.

• Never disconnect your unit by pulling on the power cord: always grip the

plug securely and pull straight out from the outlet. • Do not use a power cord that shows cracks or abrasions. Have a qualified

electrician repair or replace damaged cords immediately.

REVERSING THE FRONT DOOR: MODEL 3551.• Switch off at the socket outlet and pull out the mains plug.• Remove all food from the appliance.• Using a cross-headed screwdriver, remove the top hinge screws.• Remove the top hinge (1) while holding the door.• Lift the door carefully from the lower hinge (2).• Remove the lower hinge (3).• Reposition the upper hinge (4).• Remove the lower hinge plugs (5); remove plugs with tip of small a

screwdriver.• Reposition the door hinge bushing and plugs on the opposite side (6).• Reposition the lower hinge (7) on the opposite side and fit the hinge

washer.• Refit the door (8).• Locate the top hinge in the door and loosely attach to the cabinet.• Align the door and then tighten screws firmly on the top hinge (9)—check

that the door open and closes easily—make sure there are no gaps whichwould allow air into the cabinet (adjust the top hinge if necessary).

OPERATION: (Con’t)

REVERSING THE FRONT DOOR: MODELS 3556, 3557, 3751.

• Remove bolts and plugs using a screwdriver.

Page 45: OPERATION MANUAL - archive-resources.coleparmer.com · this manual. • Be sure to fill out the Warranty Registration Card and mail it in to Lab-Line Instruments within seven (7)

45

• Unscrew the bolts connecting the upper hinges to the upper platform (2); remove theupper platform by first pulling it forward and then lifting it upwards(3).

• Remove the door (5) by unscrewing the bolts in the upper hinges (4).• Remove the buffer (tampon) (6) by unscrewing the bolts on both of its sides.• Break off the part (7) behind the buffer through which the lower hinges pass using a

knife or your hands.• Remove the lower hinge (8) and mount it on the other side tightening its bolts.• Remove the hole plugs of the door handle (9) with a knife.• Fit the hole plugs (10) of the door handle to the other side.• Fit the buffer (11) to its place.• Mount the door (12) to its place.• Fit the upper hinges (13) into their places—do not tighten the bolts, but leave then

loose.• Adjust the vertical and parallel position of the door by eye sight, then tighten the

bolts of the upper hinges.• Fit the upper platform into its place (14).• Fit the bolts (16) connecting the upper hinges and the upper platform—but do not

tighten them.• Adjust the upper platform until it is level, then tighten the bolts in operations (15) and

(16).• Fit the plugs of the upper platform (17).

SECTION 8

TROUBLESHOOTING

Page 46: OPERATION MANUAL - archive-resources.coleparmer.com · this manual. • Be sure to fill out the Warranty Registration Card and mail it in to Lab-Line Instruments within seven (7)

46

In the event that your unit is not operating properly, check the following before calling for service assistance—this may save you the cost of unnecessary service calls.

SYMPTOM POSSIBLE CAUSES OF PROBLEM

Unit not operating: • Make certain that the unit is connected to a grounded outlet.• Make certain that temperature control knob is ON.• Check that circuit breaker is not tripped or fuse is not

blown.

Unit runs • Make certain that there is no heavy frost accumulation. If continuously: there is, defrost unit.

• Look at condenser to see if there is layer of dust or lint. Clean if required with a dry brush or vacuum.• A leak around the door gasket will allow cold air to escape.

This causes unit to work harder than necessary to maintain cold temperatures. Re-seat or replace the gasket if worn.

• If you have temperature set too cold, this may cause unit to run continuously. Check optimum running temperature.• Is the ambient air over 43ºC (109ºF), or the units located close to heat sources? If possible, move to a different location.• An unusually high frequency of door openings and closings can increase operating load. Unit will stabilize as these are decreased.

Noise problems: • This can be caused by contents of unit being set too close and rattling against each other. Rearrange contents as needed.• Hissing or gurgling noise is caused by refrigerating fluid circulating and is normal.• Noise can result if unit is not level on floor. Check with level.• Fan noise—normal air flow can cause this—not a problem.

Page 47: OPERATION MANUAL - archive-resources.coleparmer.com · this manual. • Be sure to fill out the Warranty Registration Card and mail it in to Lab-Line Instruments within seven (7)

47

SECTION 9

MAINTENANCEBE ADVISED:

MAKE NO ATTEMPT TO SERVICE OR REPAIR A LAB-LINE UNDER WARRANTY BEFORE CONSULTING YOUR LAB-LINE DEALER. AFTERTHE WARRANTY PERIOD, SUCH CONSULTATION IS STILL ADVISED,

ESPECIALLY WHEN THE REPAIR MAY BE TECHNICALLY SOPHISTICATED OR DIFFICULT.

IF ASSISTANCE IS NEEDED BEYOND WHAT THE DISTRIBUTOR CAN PROVIDE, PLEASE CALL LAB-LINE CUSTOMER SERVICEDEPARTMENT: 1-800/LAB-LINE.

NO MERCHANDISE, HOWEVER, SHOULD BE RETURNED DIRECTLY TO LAB-LINE WITHOUT PRIOR WRITTEN APPROVAL FROM LAB-LINE.

CLEANING OF UNITS: BEFORE BEGINNING

• Disconnect power cord from its outlet. • Set the temperature control to the OFF position. • The unit designs permit easy and rapid cleaning and should not take more

than a few minutes. Remember to wear protective gloves to prevent frostbite, especially when removing items from freezer units.

• Do not use abrasive scouring powders, waxes, solvents, furniture polish,

undiluted detergents or cleansers containing petroleum products on thesurfaces of units.

CLEANING INTERIOR/EXTERIOR/DOOR GASKETS:A solution of mild soap and water can be used for cleaning the interior,

exterior and door gaskets with a soft, clean cloth. Rinse with clean water and dry thoroughly before reconnecting and turning on the unit.

CONDENSER:With forced-fan vented units, remove the screws which mount the grill

to the unit. Pull temperature control knobs straight out—this will expose condenser for cleaning.

Page 48: OPERATION MANUAL - archive-resources.coleparmer.com · this manual. • Be sure to fill out the Warranty Registration Card and mail it in to Lab-Line Instruments within seven (7)

48

SECTION 10

OPTIONALGAUGE-STEEL FRAMEADJUSTABLE-LENGTHAPPLIANCE DOLLY:

A simple wing-nut adjustment shortens or lengths this dolly to fit refrigerators and freezers of various sizes.

With a capacity of up to 2,000 lbs. per pair, the dolly is 3-inches wide by 1½-inches high. It has nylon rollers and its non-skid rubber corner pads hold loadfirmly in place.

CAPACITY ADJUSTABLE ROLLERS NET WEIGHTLBS./PAIR LENGTH QTY. ID. LBS.

2000 LBS. 17—23-inches 40 1-1/8-inches 3

SECTION 11

Page 49: OPERATION MANUAL - archive-resources.coleparmer.com · this manual. • Be sure to fill out the Warranty Registration Card and mail it in to Lab-Line Instruments within seven (7)

49

OPTIONALVAPOR-PROOF OUTLET

GFCI TEST PROCEDURE:

If this unit is equipped with a GFCI-PROTECTED OUTLET, it should be checked every month to make sure that it is operating properly in order to protectthe user of this unit. Follow the procedure below and then enter test results onto the chart which follows ( next page).

1. Push BLACK TEST BUTTON: The RED RESET button should pop out from the inner surface. This should result in power being OFF at all outlets protected by the GFCI. Verify by plugging a test lamp into every outlet. If the GFCI has an indicator light, it should be ON when the circuit is complete. Test the test lamp to determine the condition of the circuit and proper operation of the indicator light.

CAUTION: IF RESET BUTTON DOES NOT POP OUT, OR IF TEST LAMP OR THE INDICATOR LIGHT REMAIN LIT WHEN RESET DOES POP OUT, DO NOT USE ANY OUTLETS ON THE CIRCUIT—CALL A QUALIFIED ELECTRICIAN FOR ASSISTANCE.

2. If the GFCI tests OK, restore power by pushing the RESET button back in. THE RESET BUTTON MUST BE PUSHED FIRMLY AND FULLY INTO PLACE UNITIL IT LOCKS AND REMAINS DEPRESSED AFTER PRESSURE HAS BEEN RELEASED—IF THE GFCI FAILS TO RESET, DO NOT USE—CALL A QUALIFIED ELECTRICIAN FOR ASSISTANCE.Test lamp and/or indicator light that should again light.

3. IF THE GFCI TRIPS BY ITSELF at any time during or after installation, reset and perform tests 1 and 2 (listed above). If reset BUTTON DOES NOT POP OUT WHEN TEST BUTTON IS DEPRESSED, DO NOT USE GFCI—CALL A QUALIFIED ELECTRICIAN FOR ASSISTANCE.

VAPOR-PROOF OUTLET: (Con’t)

GROUND FAULT CIRCUIT INTERRUPTION DUPLEX RECEPTACLEOWNER'S TEST RECORD:

Page 50: OPERATION MANUAL - archive-resources.coleparmer.com · this manual. • Be sure to fill out the Warranty Registration Card and mail it in to Lab-Line Instruments within seven (7)

50

TEST REMINDER: FOR MAXIMUM PROTECTION AGAINST ELECTRICALSHOCK HAZARD, OPERATE TEST SWITCH ON GROUNDFAULT CIRCUIT INTERRUPTER AT LEAST ONCE A MONTH.FOLLOW THE PROCEDURE ON THE PREVIOUS PAGE.

USING THE CHART: RECORD DATE WHERE APPROPRIATE: (PLACE THIS TEST CHART IN A CONSPICUOUS PLACE AS A REMINDER TO TEST REGULARLY AND TO KEEP A CONTINUOUS RECORD IN THE SPACES PROVIDED.)

JAN FEB MAR APR MAY JUNE JULY AUG SEP OCT NOV DEC

1999

2000

2001

2002

2003

2004

2005

2006

2007

2008

2009

2010

SECTION 12

REPLACEMENT PARTS

Page 51: OPERATION MANUAL - archive-resources.coleparmer.com · this manual. • Be sure to fill out the Warranty Registration Card and mail it in to Lab-Line Instruments within seven (7)

51

To obtain replacement parts information and pricing, please call the Lab-Line Customer Relations Department at the following numbers and havethe unit’s model, serial and code numbers available. This information islocated on data plates on the rear of the unit.

708/450-2600 (in Illinois) 1-800/LAB-LINE (elsewhere)

Page 52: OPERATION MANUAL - archive-resources.coleparmer.com · this manual. • Be sure to fill out the Warranty Registration Card and mail it in to Lab-Line Instruments within seven (7)

52

WARRANTYPage 1 of 2

LAB-LINE INSTRUMENTS, INC. (“Lab-Line”) warrants that the product manufactured byLab-Line shall be free of defects in materials and workmanship for a period of timedefined on the following page from the first to occur of (i) the date the product is sold byLab-Line or (ii) the date the product is purchased by the original retail customer (the“Commencement Date”). Except as expressly stated above,

Page 53: OPERATION MANUAL - archive-resources.coleparmer.com · this manual. • Be sure to fill out the Warranty Registration Card and mail it in to Lab-Line Instruments within seven (7)

53

LAB-LINE MAKES NO OTHER WARRANTY, EXPRESSED OR IMPLIED, WITHRESPECT TO THE PRODUCTS AND EXPRESSLY DISCLAIMS ANY AND ALLWARRANTIES, INCLUDING BUT NOT LIMITED TO, WARRANTIES OF DESIGN,MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE.

An authorized representative of Lab-Line must perform all warranty inspections. In theevent of a defect covered by Lab-Line’s warranty, Lab-Line shall, as its sole obligationand exclusive remedy, provide free replacement parts to remedy the defective product.In addition, for products sold by Lab-Line within the continental United States orCanada, Lab-Line shall provide free labor to repair the products with the replacementparts, but only for a period of ninety (90) days from the Commencement Date.

Lab-Line’s warranty provided hereunder shall be null and void and without further forceor effect if there is any (i) repair made to the product by a party other than Lab-Line orits duly authorized service representative, (ii) misuse (including use inconsistent withwritten operating instructions for the product), mishandling, contamination, overheating,modification or alteration of the product by any customer or third party or (iii) use ofreplacement parts that are obtained from a party who is not an authorized dealer of Lab-Line.

IN NO EVENT SHALL LAB-LINE BE LIABLE TO ANY PARTY FOR ANY DIRECT,INDIRECT, SPECIAL, INCIDENTAL, OR CONSEQUENTIAL DAMAGES, OR FORANY DAMAGES RESULTING FROM LOSS OF USE OR PROFITS, ANTICIPATEDOR OTHERWISE, ARISING OUT OF OR IN CONNECTION WITH THE SALE, USEOR PERFORMANCE OF ANY PRODUCTS, WHETHER SUCH CLAIM IS BASED ONCONTRACT, TORT (INCLUDING NEGLIGENCE), ANY THEORY OF STRICTLIABILITY OR REGULATORY ACTION.

The name of your nearest authorized Lab-Line dealer may be obtained by calling 1-800-522-5463.

DESIGNERS AND MANUFACTURERS A SUBSIDIARY of Barnstead|Thermolyne1999 North 15th Ave., Melrose Park, IL 60160-1491 USA PHONE: (319) 556-2241 or (800) 522-5463; FAX: (319) 589-0516

WARRANTYPage 2 of 2

12 MONTH PARTS WARRANTY:• All Environmental Chambers• Low Temperature B. O. D. Incubators• Animal Study Chamber• Controlled Environment Centers• Biological Work Station

Page 54: OPERATION MANUAL - archive-resources.coleparmer.com · this manual. • Be sure to fill out the Warranty Registration Card and mail it in to Lab-Line Instruments within seven (7)

54

• Refrigerators, Freezers• Chromatography Refrigerators (5 year parts warranty on compressor only)• Large Capacity Refrigerators and Freezers (5 year parts warranty on compressor

only)

24 MONTH PARTS WARRANTY:• Frame Clamps, Frame Sets, Lab Jacks• Saybolt Viscosimeter• Timers, Samplers, Flasks• Saf-T-Shield, Safety Tongs• All Incubators & Ovens• Dual Action Open Air Shaker• Reciprocating Shakers (open air and water bath)• Rockers and Rotators• Low Cost Shakers• Environ Blok Shaker• Titer Plate Shaker• Multi Wrist Shaker• Water Baths (excluding Aquabaths), Ultrasonic Cleaners• Slide Warmers• Mixers, Stirrers, Hotplates• Thermal Cyclers• Blok Heaters• Aquabaths, lifetime warranty on heaters

LIFETIME PARTS WARRANTY:• All ORBITAL Shakers (not carrying a 24 month parts warranty) offer a lifetime

parts warranty on the drive mechanism and a 5 year warranty on all other parts• Refrigerated Orbital Shakers carry a lifetime warranty on the drive mechanism,

1 year parts warranty on the compressor, and a 5 year warranty on all otherparts.

Page 55: OPERATION MANUAL - archive-resources.coleparmer.com · this manual. • Be sure to fill out the Warranty Registration Card and mail it in to Lab-Line Instruments within seven (7)

55

FIRST IN INSTRUMENTS SERVICING SCIENCE, INDUSTRY,RESEARCH AND EDUCATION

SINCE 1908.

Page 56: OPERATION MANUAL - archive-resources.coleparmer.com · this manual. • Be sure to fill out the Warranty Registration Card and mail it in to Lab-Line Instruments within seven (7)

56

Page 57: OPERATION MANUAL - archive-resources.coleparmer.com · this manual. • Be sure to fill out the Warranty Registration Card and mail it in to Lab-Line Instruments within seven (7)

57

ACCESSORY CHECKLIST

The following loose parts and accessories are packed withthis unit. Before discarding any packing materials, please be sure thatnothing has been overlooked.

MODEL NO. 3551 3556 3560 37623551-1 3556-1 3560-1 3762-13551-10 3556-2 3560-10 37633551-11 3556-4 3560-11 3763B3552 3556-6 3750 3763-1 3552-1 3557 3750-1 3764 3552-10 3557-1 3750-2 3764-1 3552-11 3557-2 3751 3766 3555 3557-3 3751-1 3766BR3X

3555-1 3557-4 3751BK 3766-13555-6 3557-5 3767B 37673555-7 3559 3752 3767BR3X3559-10 3559-1 3752P2 3767R173559-11 3752R17 3752-1 3767-13764L 3750V 3761 3770

3551KL 3763BXK 3761-1 3752-2 3764K 3763L 3566-1 3566-10 3763XR27 3751L 3566 3566-11

CHECKED BY: __________

DATE __________

PACKED BY __________

CHECKED ITEM PART NUMBER QUANTITY

_________ Operation Manual 057-196-00 1