3 conductor plus 3 bare grounds 4 conductor (3 conductor with ground) plus 1 or 4 bare grounds MCM Power VFD cable WWW.PRIORITYWIRE.COM In U.S. 1-800-945-5542 Fax: 1-501-372-1103 In Canada 1-877-611-5122 Fax: 1-905-564-9769 When TIME and EFFICIENCY are just as important as PRICE and QUALITY… We make your business our PRIORITY 13 DISTRIBUTION CENTERS Part Number PN M-LIT-VFD ©Priority Wire & Cable March 2017 VFD (Variable Frequency Drive) Cables Visit our website to sign up and check inventory WWW.PRIORITYWIRE.COM Our Complete Product Line ALUMINUM PRODUCTS Factory Pricing • Aluminum THHN Colors • Aluminum XHHW Colors • Aluminum MC Cable Feeder Sizes • Aluminum SER and SEU • Aluminum USE-2 (8000) • Aluminum XLP-USE (1350) • 600 Volt UD Cable • Aluminum UD Cable 8000 Series • Aluminum Service Drop Cable • Aluminum ACSR-AAC-AAAC • Aluminum Tie Wire • 15 & 35KV Aluminum URD Cable • MV 105 Aluminum 15 & 35KV NON-WIRE PRODUCTS • Copper And Galvanized Ground Rods & Accessories • Flexible Conduit (EFLT, UALT, NMLT, RWA, RWS) • Splice & Term Kits Med Voltage • Lugs • Glands for Type P MARKET SENSITIVE ITEMS • Bare Copper • 12-02 MC Cable • Copper THHN VALUE ADDED SERVICES • Striping • Custom Cuts • Paralleling • Same Day Shipping • Pulling Eyes • Order Acknowledgement • No Minimum • Stacking/Layering COPPER PRODUCTS Factory Pricing • Portable Cord SOOW / SJOOW • Portable Cord SEOOW / SJEOOW • MC Cable (with proper mix) • Type G-GC, Type W • DLO • Welding Cable • Mining Cable SHDGC, G-GC, MP-GC • 8-03, 6-03, 4-03, 2-03 MC Cable • Flextel ® Central Office Power • Security & Fire Alarm • Thermostat Wire • Coax Cable, Smart Cable • Cat 5E / Cat 6 • Tracer Wire (CCS) • Specialty MC Cable Jacketed, Multi Conductor • Outside Plant (PE39, PE54, PE89) • 20/10 Control Cable • Tinned Copper • Range / Dryer Cords • Extension Cords SPECIALTY WIRE AND CABLE • CableX © • Aluminum MV 105 5, 15 & 35KV Copper & Aluminum • Tray Cable THHN, XLPE • Instrumentation and Control • Thermocouple • VFD (Variable Frequency Drive) • PV Cable (PHOTOVOLTAIC CABLE) Copper & Aluminum • SER Copper • SIS - Switchboard • High Temperature (MG, TGGT, SRML) • Electronic / Computer Cables • AirGuard ® • Teck 90 • Medium Voltage MV 90 2.4 KV • Airport Lighting Cable • MTW, TFN, TFFN • XHHW, XLP/USE-2 Copper • Type P (glands available) • String Lights • 400 Watt Metal Halide • Lifeline ®

Our Complete Product Line - Priority Wire & Cable cable.pdf · 3 conductor plus 3 bare grounds 4 conductor (3 conductor with ground) plus 1 or 4 bare grounds MCM Power VFD cable In

  • Upload
    dangnga

  • View
    223

  • Download
    2

Embed Size (px)

Citation preview

3 conductor plus 3 bare grounds4 conductor (3 conductor with ground) plus 1 or 4 bare grounds

MCM Power VFD cableWWW.PRIORITYWIRE.COMIn U.S. 1-800-945-5542 • Fax: 1-501-372-1103

In Canada 1-877-611-5122 • Fax: 1-905-564-9769

When TIME and EFFICIENCY are just as important as PRICE and QUALITY…

We make your business our PRIORITY

13 DISTRIBUTION CENTERS

Part Number PN M-LIT-VFD©Priority Wire & Cable March 2017

VFD (Variable Frequency Drive) CablesVisit our website to sign up and check inventory

WWW.PRIORITYWIRE.COM

Our Complete Product LineALUMINUM PRODUCTS Factory Pricing • Aluminum THHN Colors• Aluminum XHHW Colors• Aluminum MC Cable Feeder Sizes• Aluminum SER and SEU• Aluminum USE-2 (8000)• Aluminum XLP-USE (1350)• 600 Volt UD Cable• Aluminum UD Cable 8000 Series• Aluminum Service Drop Cable• Aluminum ACSR-AAC-AAAC• Aluminum Tie Wire• 15 & 35KV Aluminum URD Cable• MV 105 Aluminum 15 & 35KV

NON-WIRE PRODUCTS • Copper And Galvanized Ground Rods & Accessories• Flexible Conduit (EFLT, UALT, NMLT, RWA, RWS)• Splice & Term Kits Med Voltage• Lugs• Glands for Type P

MARKET SENSITIVE ITEMS • Bare Copper• 12-02 MC Cable• Copper THHN

VALUE ADDED SERVICES • Striping • Custom Cuts• Paralleling • Same Day Shipping• Pulling Eyes • Order Acknowledgement• No Minimum • Stacking/Layering

COPPER PRODUCTS Factory Pricing • Portable Cord SOOW / SJOOW• Portable Cord SEOOW / SJEOOW• MC Cable (with proper mix)• Type G-GC, Type W• DLO• Welding Cable• Mining Cable SHDGC, G-GC, MP-GC• 8-03, 6-03, 4-03, 2-03 MC Cable• Flextel® Central Office Power• Security & Fire Alarm• Thermostat Wire• Coax Cable, Smart Cable• Cat 5E / Cat 6• Tracer Wire (CCS)• Specialty MC Cable Jacketed, Multi Conductor• Outside Plant (PE39, PE54, PE89)• 20/10 Control Cable• Tinned Copper• Range / Dryer Cords• Extension Cords

SPECIALTY WIRE AND CABLE • CableX©

• Aluminum MV 105 5, 15 & 35KV Copper & Aluminum• Tray Cable THHN, XLPE• Instrumentation and Control• Thermocouple• VFD (Variable Frequency Drive)• PV Cable (PHOTOVOLTAIC CABLE) Copper & Aluminum• SER Copper• SIS - Switchboard• High Temperature (MG, TGGT, SRML)• Electronic / Computer Cables• AirGuard®

• Teck 90• Medium Voltage MV 90 2.4 KV• Airport Lighting Cable• MTW, TFN, TFFN• XHHW, XLP/USE-2 Copper• Type P (glands available)• String Lights• 400 Watt Metal Halide• Lifeline®

Three Conductor Variable Frequency Drive Cable600V UL Type TC-ER / 1000V UL Type Motor Supply

Four Conductor Variable Frequency Drive Cable600V UL Type TC-ER / 1000V UL Type Motor Supply

MCM Variable Frequency Drive Cable600V UL Type TC-ER

Three Conductor Variable Frequency Drive Cables are primarily used with VFD’s. The three conductor construction is suitable for applications that are generally dry with one-phase fault conditions, where an insulated ground is not requited.

Four Conductor Variable Frequency Drive Cables are primarily used with VFD’s. The four conductor construction is more effective than the three conductor version to reduce the effects of EMI interference in the event of a component failure. The ground is isolated from shielding which blocks transient current and thus nearby equipment and cable will not be affected.

MCM Variable Frequency Drive Cables are primarily used with VFD’s. The three conductor construction is suitable for applications that are generally dry with one-phase fault conditions, where an insulated ground is not requited.

Conductors: Three Conductor Variable Frequency Drive Cable has stranded soft drawn copper conductors. 14ga through 4ga are tinned copper. 2ga and larger are bare copper.Ground(s): Three Conductor Variable Frequency Drive Cable has stranded soft drawn copper grounds. Conductor sizes14ga through 4ga are tinned copper. 2ga and larger are bare copper.Insulation: Three Conductor Variable Frequency Drive Cable has cross-linked polyethylene XLP insulation.Shielding: Three Conductor Variable Frequency Drive Cables from 16 to 4 gauge they have aluminum polyester & 85% tinned copper braid shield. For cables 2 gauge & larger they have a .005” helical bare copper tape shield, with a 50% overlap.Jacket: Three Conductor Variable Frequency Drive Cable has a black polyvinyl chloride PVC jacket that is sunlight, moisture, oil and abrasion resistant and direct burial rated, for use from -40C to 90C.Standards: UL 1277, Type TC-ER, Type XHHW-2 UL approved as 1000V flexible motor supply cable UL listed as VFD per UL 2277 for Flexible VFD Servo Motor Cables CSA FT-4 Vertical tray flame test CSA AWM I/II A/B singles Type C(UL) CIC-TC per CSA standard C22.2 No. 239-09 & 230-09 Meets UL 1202/1581 70,000 BTU flame test Meets ICEA T-29-520 210,000 BTU flame test Suitable for use in Class I Division II hazardous locations RoHS II & REACH compliant

Conductors: Four Conductor Variable Frequency Drive Cable has stranded soft drawn tinned copper conductors.Drain(s): Four Conductor Variable Frequency Drive Cable has a stranded soft drawn tinned copper ground(s).Insulation: Four Conductor Variable Frequency Drive Cable has cross-linked polyethylene XLP insulation.Shielding: Four Conductor Variable Frequency Drive Cable has aluminum polyester & 85% tinned braid shields.Jacket: Four Conductor Variable Frequency Drive Cable has a polyvinyl chloride PVC jacket that is sunlight, moisture, oil and abrasion resistant and direct burial rated. The cable is 600V rated and for use from -40C to 90C.Standards: UL 1277, Type TC-ER, Type XHHW-2 UL approved as 1000V flexible motor supply cable UL list as Type VFD per UL 2277 for Flexible VFD Servo Motor Cables CSA FT-4 Vertical tray flame test CSA AWM I/II A/B singles C(UL) CIC-TC per CSA standard C22.2 No. 239-09 & 230-09 Meets UL 1202/1581 70,000 BTU flame test Meets ICEA T-29-520 210,000 BTU flame test Suitable for use in Class I Division II hazardous locations RoHS II & REACH compliant

Conductors: MCM Variable Frequency Drive Cable has stranded soft drawn bare copper conductors. Ground(s): MCM Variable Frequency Drive Cable has stranded soft drawn bare copper grounds.Insulation: MCM Variable Frequency Drive Cable has cross-linked polyethylene XLP insulation.Shielding: MCM Variable Frequency Drive Cables have two .005” helical bare copper tape shield, with 50% overlaps.Jacket: MCM Variable Frequency Drive Cable has a black polyvinyl chloride PVC jacket that is sunlight, moisture, oil and abrasion resistant and direct burial rated, for use from -40C to 90C.Standards: UL 1277, Type TC-ER, Type XHHW-2 Meets UL 1202/1581 70,000 BTU flame test Meets ICEA T-29-520 210,000 BTU flame test Suitable for use in Class I Division II hazardous locations RoHS II & REACH compliant

Application: Application:

Application:

Conductor Ground Insulation Jacket Nominal Size Conductor Wire(s) Size Thickness Thickness O.D. Ampacity Part Number (AWG) Stranding (AWG) (inches) (inches) (inches) @30C** 14-03VFD-3G 14 41 3#18 0.03 0.045 0.413 25 12-03VFD-3G 12 65 3#16 0.03 0.045 0.464 30 10-03VFD-3G 10 105 3#14 0.03 0.06 0.553 40 8-03VFD-3G 8 133 3#14 0.045 0.06 0.719 55 6-03VFD-3G 6 133 3#12 0.045 0.08 0.854 75 4-03VFD-3G 4 133 3#12 0.045 0.08 0.945 95 2-03VFD-3G 2 133 3#6 0.045 0.08 1.112 130 1-03VFD-3G 1 133 3#6 0.055 0.08 1.176 145 1/0-03VFD-3G 1/0 133 3#4 0.055 0.08 1.334 170 2/0-03VFD-3G 2/0 133 3#4 0.055 0.08 1.444 195 3/0-03VFD-3G 3/0 133 3#4 0.055 0.08 1.467 225 4/0-03VFD-3G 4/0 133 3#2 0.055 0.11 1.732 260

Conductor Drain Insulation Jacket Nominal Size Conductor Wire(s) Size Thickness Thickness O.D. Ampacity Part Number (AWG) Stranding (AWG) (inches) (inches) (inches) @30C** 16-04VFD 16 26 16 0.030 0.045 0.401 18 14-04VFD 14 41 14 0.030 0.045 0.432 25 12-04VFD 12 65 12 0.030 0.045 0.601 30 10-04VFD 10 105 10 0.030 0.060 0.574 40 8-04VFD 8 133 4#14 0.045 0.060 0.774 55 6-04VFD 6 133 4#12 0.045 0.080 0.922 75 4-04VFD 4 133 4#10 0.045 0.080 1.040 95 2-04VFD 2 133 4#10 0.045 0.080 1.236 130

Conductor Ground Insulation Jacket Nominal Size Conductor Wire(s) Size Thickness Thickness O.D. Ampacity Part Number (AWG) Stranding (AWG) (inches) (inches) (inches) @30C** 250-03VFD-3G 250 37 3#8 0.065 0.080 1.680 290 350-03VFD-3G 350 37 3#6 0.065 0.110 1.961 350 500-03VFD-3G 500 37 3#6 0.065 0.110 2.236 430

**Ampacity values based on NEC 2014, Table 310.15(B)(16), NEC 2014 Annexures B, C & D, Article 240, with values corrected to Table

310.15(B)(3)(a) for the number of conductors. All values are nominal and subject to correction

**Ampacity values based on NEC 2014, Table 310.15(B)(16), NEC 2014 Annexures B, C & D, Article 240, with values corrected to Table

310.15(B)(3)(a) for the number of conductors. All values are nominal and subject to correction

** Ampacity values based on NEC 2011, Table 310.15(B)(16), with values corrected to Table 310.15(B)(3)(a) for the number of conductors

All values are nominal and subject to correction

VFD

Cabl

es VFD cables feature a black polyvinyl chloride PVC jacket that is sunlight, moisture, oil and abrasion resistant and direct burial rated, for use from -40C to 90C. The insulation on the inner conductors is cross-linked polyethylene XLP insulation.

Three or Four Conductor ConfigurationsThree-conductor cables have three insulated conductors and three bare grounds or drains. They offer advantages in improved ground path that helps reduce both common mode and differential noise. This minimizes the potential of noise induced motor damage.

Four-conductor cables feature one insulated ground and one to four additional bare grounds or drain wires. The insulation isolates the ground wire form the shield so that transient currents will be blocked by the overall shield and nearby communication cables and other equipment won’t be disrupted.

Three-conductor Cable Four-conductor Cable with 1 to 4 bare grounds