BUILDING SECTION SYMBOL WALL SECTION SYMBOL
ELEVATION SYMBOLS REFERENCE KEYNOTE SYMBOL
A101
1SIM
DETAIL SYMBOL
A101
1SIM
SIMILAR, TYPICAL, OR MIRRORED REFERENCE
SIMILAR, TYPICAL, OR MIRRORED REFERENCE
SPOT DIMENSIONS
HEIGHT INDICATION (ABOVE RESPECTIVE GROUND FLOOR LEVEL ELEVATION)
0'-0"
WINDOW/ DOOR TAG SYMBOLS
WALL TAG SYMBOL
PARTITION TYPE
1,234 SF
12
ROOM NUMBER
AREA
OCCUPANT LOAD
ROOM TAG SYMBOL
Room name101
CH= 1'-0"
CEILING TAG SYMBOL
HEIGHT INDICATION (ABOVE RESPECTIVE FLOOR LEVEL ELEVATION)
DETAIL
SHEET NUMBER
SHEET NUMBER
BUILDING SECTIONNUMBER
SHEET NUMBER
DETAIL
SHEET NUMBER
BUILDING SECTION NUMBER
SHEET NUMBER
ELEVATION NUMBER
A1 A101
E3/A504
DETAIL / SHEET #E3/A
504
A101
1SIM
A101
1SIM
A101
1SIM
1
A101
1t
101 DOOR TAG
1tWINDOW TAG
1
KEYED NOTE - REFERS TO KEYNOTE LEGEND ON EACH SHEET
PROJECT LOCATION
STEWART ST.
BR
ELA
ND
DR
.
S. LO
CU
ST
ST
.
WIL
LIA
MS
AV
E.
SW
EE
T A
VE
.
ES
PIN
A S
T.
OFFICE
138
OFFICE
136
WORK ROOM
163
OFFICE
163B
CONFERENCE ROOM
163L
OFFICE
163C
OFFICE
163D
OFFICE
163E
OFFICE
163F
OFFICE
163K
OFFICE
163A
OFFICE
163G
ASSIST. DEAN
163H
ASSOC. DEAN
163I
DEAN'S OFFICE
164
SECRETARIAL
163M
HALL
100
HALL
102
OCCUPANCY CLASSIFICATION: B (BUSINESS)FUNCTION OF SPACE: BUSINESS AREAOCCUPANT LOAD FACTOR: 100 GROSSNUMBER OF OCCUPANTS: 43
OCCUPANCY CLASSIFICATION: B (BUSINESS)FUNCTION OF SPACE: ACCESSORY STORAGE AREASOCCUPANT LOAD FACTOR: 300 GROSSNUMBER OF OCCUPANTS: 1
2
3
4
1
2
2
1
2
2
4
2
2
2
1
22
10
D
A
3
5
16
21
B
C
6
9
2311
12
16
5
21
MAX TRAVEL DISTANCE: 88'
MAX TRAVEL DISTANCE: 100'
3'-0
"
#
#
A
TOTAL NUMBER OF OCCUPANTS IN ROOM
COMBINED NUMBER OF OCCUPANTS ALONG COMMON PATH OF TRAVEL
EXIT IDENTIFICATION
PROJECT INFORMATION
MODIFICATIONS TO EXISTING BUILDING LEVEL OF ALTERATIONS: LEVEL 1
Per IBC 2015 - 304.1EXISTING OCCUPANCY CLASSIFICATION - GROUP B (UNCHANGED)
EXISTING CONSTRUCTION TYPE - IIIBSPRINKLERED: NO
TOTAL GSF OF SUITE: 4,691 GSF
MEANS OF EGRESS - Per IBC 2015 CHAPTER 10
MINIMUM REQUIRED EGRESS STAIRS 0.3"/ OCCUPANTEXITS 0.2"/ OCCUPANTEGRESS DOORS: 32" MINIMUM CLEAR
EXIT TRAVEL DISTANCE REQUIREMENTS - Per IBC 2015 1017.2
OCCUPANCY CLASSIFICATION B (NON- SPRINKLERED) - 200'-0" MAX DISTANCE
OCCUPANT LOAD FACTOR - Per IBC 2015 1004.1.2
BUSINESS AREA (B) - 100 GSF/OCCUPANTOCCUPANT LOAD: 4,278 GSF/100 = 43 OCCUPANTS
ACCESSORY STORAGE AREAS - 300 GSF/OCCUPANTOCCUPANT LOAD: 1
TOTAL OCCUPANT LOAD: 44 OCCUPANTS
EXIT CORRDOR WIDTH REQUIREMENTS - Per IBC 2015 1020.2
OCCUPANCY: "AN OCCUPANT LOAD OF LESS THAN 50"
REQUIRED: 36" CLEAR WIDTH EXISTING WIDTH: 53" MIN.
CODE REVIEW
PROJECT INFORMATION
MAX DISTANCE= 99'-0"
A. Additive Alternate #1 – Renovations to room 163 G to include:a. Removal and replacement of existing carpetb. Removal and replacement of existing light fixtures and new LED
fixtures to match the new light fixtures in the suite’s conference room
c. Removal and replacement of the existing HVAC grilles and diffusers to match the new diffusers in the suite’s conference room
d. Removal and replacement of the acoustical ceiling tiles to match the new ceiling tiles in the suite’s conference room. Existing ceiling grid to remain and to receive new paint. Modify ceiling grid as required for new lighting layout.
e. Preparation of existing substrates for new paint throughout U.N.O. New paint to be provided throughout the suite U.N.O.
B. Additive Alternate #2 – Re-finishing of existing closet doorsa. Removal of existing closet doors and door hardware as indicated
on the drawings.b. Strip existing finish coat and stain. Sand surface with fine grit
sandpaper. Re-stain and finish (clear coat) to match door on conference room 163L or as selected by NMSU Architect
ALTERNATE SCHEDULE
RE
G
I ST ERED A RCH
I T
EC
T
ST
AT
E
OF NEWMEX
ICORICHARD HAAS
NO. 2530
This document may not be reproduced in whole or part by any means, electronic or otherwise without the explicit written permission of Desert Peak Architects P.C.. All reports, plans, specifications, computer files, field data and other documents and instruments prepared by the Architect as instruments of service shall remain the property of the Architect. The Architect shall retain all common law, statutory, and other reserved rights, including the copyright thereto.
DESERT PEAK ARCHITECTS P.C.311 N MAIN STREETLAS CRUCESNEW MEXICO 88001P. 575.528.0022
SHEET NO.
SHEET TITLE
ISS
UE
:
D
C
B
A
1 3 4 52
PROJECT NO.206-101
G001
COVER SHEET
10/0
7/2
019
DE
AN
'S S
UIT
E R
EN
OV
AT
ION
S
NM
SU
, B
RE
LA
ND
HA
LL
15
25
ST
EW
AR
T S
T.
LA
S C
RU
CE
S, N
M 8
80
03
CO
NS
TR
UC
TIO
N D
OC
UM
EN
TS
10/07/2019
DRAWING INDEXOWNER:NEW MEXICO STATE UNIVERSITY
CONTACT: ROBERT ESTRADA - PROJECT MANAGER
CONSULTANTS:
ARCHITECT:
DESERT PEAK ARCHITECTS, INC
311 NORTH MAIN STREET
LAS CRUCES, NM 88005
P. (575) 528 - 0021
CONTACT: RICHARD HAAS
VICINITY MAP
DEAN'S SUITE RENOVATIONSCOVER G-SHEETS
G001 COVER SHEET
NMSU - BRELAND HALL1525 STEWART ST.
ELECTRICAL
E2.0 FIRST FLOOR LIGHTING PLAN
ELECTRICAL ENGINEER
PILLAR ENGINEERING, LLC.280 EAST FOSTER STE B.LAS CRUCES, NM 88005P: (575) 647-1927
CONTACT: MARTIN PILLAR, PE
SYMBOL LEGEND
2015 INTERNATIONAL BUILDING CODE2015 EXISTING BUILDING CODE2015 NM COMMERCIAL CODES2015 UNIFORM MECHANICAL CODE2015 NM MECHANICAL CODE2017 NATIONAL ELECTRICAL CODE2017 NM ELECTRICAL CODE2009 INTERNATIONAL ENERGY CONSERVATION CODE
DESIGN CODES
ARCHITECTURAL
A101 FIRST FLOOR PLAN & REFLECTED CEILING PLAN
A602 WALL PARTITION TYPES AND SCHEDULES
D101 DEMOLITION PLAN
DEMOLITION
1/8" = 1'-0"G001A1 FIRST FLOOR PLAN - OCCUPANCY/LIFE SAFETY DIAGRAM
PROJECT NORTH
LEGEND
EXIT SCHEDULE
A 34" .2 170 23
B 64" .2 320 23
C 64" .2 320 23 + ADDITIONAL BUILDING OCCUPANTS (OCCUPANCY COUNT REMAINS UNCHANGED IN NEW WORK)
D 64" .2 320 21
MARK WIDTH OF OPENING
FACTOR ALLOWABLE # OF OCCUPANTS SERVED
ACTUAL # OF OCCUPANTS SERVED
OPERABLE GATE - BY
OTHERS
NMSU PROJECT # 3568
STAGING & STORAGE
WORK AREA
STEWART ST.
BR
ELA
ND
DR
.
PROPOSED LOCATION FOR STAGING AND STORING. COORDINATE WITH NMSU
BRELAND HALL
Mark
Date
Description
DEAN'S OFFICE
164
OFFICE
163A
SECRETARIAL
163M
ASSOC. DEAN
163I
ASSIST. DEAN
163HOFFICE
163F
OFFICE
163E
OFFICE
163D
OFFICE
163C
OFFICE
163B
CONFERENCE ROOM
163L
OFFICE
163K
NO WORK THIS AREA
NO WORK THIS AREA
NO WORK THIS AREA
3
3
3
33
3
3
3
3
33
3
3
33
3
3
33
3
4
4
4444
4
4
4
4
4
44
NO WORK THIS AREA
NO WORK THIS AREA
3
3
4
4
NO WORK THIS AREA
NO WORK THIS AREA
NO WORK THIS AREA
NO WORK THIS AREA
NO WORK THIS AREA
ALTERNATE #1:RENOVATIONS TO ROOM 163G. REFER TO ALTERNATE SCHEDULE
OFFICE
163G
5
5
5
5
5
5 5
6
7
7
7
OFFICE
138
OFFICE
136
12
13
14
TYP
5
156"
16
5 5
5
3
3
3
3
20
NO WORK THIS AREA
NO WORK THIS AREA
1
TYP
1
TYP
2
2
2
2
2
2
2
2
2
2
2
22
NO WORK THIS AREA
NO WORK THIS AREA
NO WORK THIS AREA
NO WORK THIS AREA
NO WORK THIS AREA
NO WORK THIS AREA
ALTERNATE #1:RENOVATIONS TO ROOM 163G. REFER TO ALTERNATE SCHEDULE
11
8
8
OFFICE
138
OFFICE
136
OFFICE
163B
OFFICE
163C
OFFICE
163D
OFFICE
163E
OFFICE
163K
OFFICE
163F
OFFICE
163G ASSIST. DEAN
163H
ASSOC. DEAN
163I
SECRETARIAL
163M
OFFICE
163A
DEAN'S OFFICE
164
HALL
100
WORK ROOM
163
CONFERENCE ROOM
163L
1
TYP
1
2
TYP
9
9
9
1 TYP
1
TYP
1
TYP
10
101
TYP
1
TYP
1
TYP
11
11
11
11
11
11
11 11
1111
11
1111
11
9
9
17
17
17
18
19
19
A. DIMENSIONS ARE NOMINAL FROM FACE OF EXISTING.B. THE CONTRACTOR SHALL VISIT THE SITE AND VERIFY ALL EXISTING CONDITIONS
AND SHALL NOTIFY ARCHITECT OF ANY DISCREPANCIES.C. CONTRACTOR SHALL PROVIDE TEMPORARY BARRIERS DURING CONSTRUCTION
TO PROVIDE DUST AND DEBRIS CONTROL. CONTRACTOR TO COORDINATE BARRIER LOCATIONS WITH OWNER/ARCHITECT.
D. CONTRACTOR SHALL PROTECT ALL EXISTING TO REMAIN ITEMS WITHIN THE WORK AREA TO PREVENT DAMAGE. THE CONTRACTOR IS RESPONSIBLE FOR REPAIRING ANY DAMAGE DONE TO EXISTING CONDITIONS TO REMAIN.
E. CONTRACTOR SHALL COORDINATE SITE ACCESS AND STAGING AREA WITH OWNER/ARCHITECT.
F. THE CONTRACTOR SHALL REPAIR AND REPLACE ANY ITEM OR SURFACE DAMAGED BY THE WORK, OR AS REQUIRED BY NEW INSTALLATION.
G. ALL DEMOLISHED MATERIALS TO BE REMOVED FROM SITE. U.N.O.H. CONTRACTOR SHALL KEEP ALL EXISTING EXIT WAYS CLEAR AND OPEN DURING
CONSTRUCTION.I. HAZRDOUS MATERIALS - IT IS NOT EXPECTED THAT HAZARDOUS MATERIALS
WILL BE ENCOUNTERED DURING THE WORK. UPON DISCOVERY OF HAZARDOUS MATERIALS, CONTRACTOR SHALL STOP WORK AND INFORM THE OWNER/ARCHITECT
J. REMOVE ALL EXPOSED CONDUIT AND WIRE-MOLD THAT IS NOT TO BE RE-USED.REMOVE ALL POWER AND LOW VOLTAGE WIRES THAT ARE NOT RE-USED BACK TO THE NEAREST JUNCTION BOX.
N
RE
G
I ST ERED A RCH
I T
EC
T
ST
AT
E
OF NEWMEX
ICORICHARD HAAS
NO. 2530
This document may not be reproduced in whole or part by any means, electronic or otherwise without the explicit written permission of Desert Peak Architects P.C.. All reports, plans, specifications, computer files, field data and other documents and instruments prepared by the Architect as instruments of service shall remain the property of the Architect. The Architect shall retain all common law, statutory, and other reserved rights, including the copyright thereto.
DESERT PEAK ARCHITECTS P.C.311 N MAIN STREETLAS CRUCESNEW MEXICO 88001P. 575.528.0022
SHEET NO.
SHEET TITLE
ISS
UE
:
D
C
B
A
1 3 4 52
WORK AREA
PROJECT NO.206-101
D101
DEMOLITION PLAN
10/0
7/2
019
DE
AN
'S S
UIT
E R
EN
OV
AT
ION
S
NM
SU
, B
RE
LA
ND
HA
LL
15
25
ST
EW
AR
T S
T.
LA
S C
RU
CE
S, N
M 8
80
03
CO
NS
TR
UC
TIO
N D
OC
UM
EN
TS
10/07/2019
PROJECT NORTH
KEYNOTE LEGEND1 CAREFULLY REMOVE AND DISPOSE OF EXISTING LIGHT FIXTURES. LIGHT FIXTURES TO BE REPLACED WITH
NEW, LED LIGHT FIXTURES IN NEW WORK.
2 CAREFULLY REMOVE EXISTING CEILING TILES AND CEILING MOUNTED EQUIPMENT. CEILING GRID TO
REMAIN. CONTRACTOR IS RESPONSIBLE FOR REPAIRING ANY DAMAGE DONE TO THE EXISTING CEILING
GRID DURING CONSTRUCTION
3 REMOVE AND DISPOSE OF EXISTING COVE BASE. PATCH / REPAIR WALL AS REQUIRED FOR NEW FINISHES
4 REMOVE AND DISPOSE OF EXISTING BROADLOOM CARPET IN THIS AREA. PREP FLOORS FOR NEW CARPET
TILE
5 CAREFULLY REMOVE EXISTING DOOR AND DOOR HARDWARE FROM FRAME. KEEP IN CLEAN, SAFE AREA FOR
RE-USE. DOORS TO BE RE-FINISHED IN NEW WORK.
6 EXISTING DOOR TO REMAIN. NO WORK.
7 ALTERNATE #2 - CAREFULLY REMOVE EXISTING DOOR AND DOOR HARDWARE FROM FRAME FOR CLOSET
DOORS SHOWN. KEEP IN CLEAN, SAFE AREA FOR RE-USE. DOORS TO BE RE-STAINED IN NEW WORK.
8 EXISTING 12" x 12" ADHERED ACOUSTIC TILE CEILING TO REMAIN. PATCH/REPAIR AS REQUIRED - PAINT IN
NEW WORK. COLOR AS SELECTED BY NMSU ARCHITECT.
9 EXISTING LED LIGHT FIXTURES. REMOVE AND STORE IN CLEAN, SAFE AREA. LIGHT FIXTURES TO BE
RELOCATED IN NEW WORK.
10 EXISTING 2' X 2' LED LIGHT FIXTURE TO REMAIN. REMOVE AND REPLACE AS REQUIRED FOR NEW WORK.
11 CAREFULLY REMOVE AND DISPOSE OF EXISTING SUPPLY AND RETURN DIFFUSERS. DIFFUSERS TO BE
REPLACED IN NEW WORK.
12 REMOVE EXISTING UPPER CABINETS AS SHOWN. PATCH / REPAIR WALL AS REQUIRED FOR NEW FINISHES
13 REMOVE UPPER CABINETS, BASE CABINETS AND COUNTERTOP IN THIS AREA. PATCH / REPAIR WALL AS
REQUIRED FOR NEW FINISHES
14 REMOVE EXISTING ROOM SIGNAGE THROUGHOUT THE SUITE - PATCH/REPAIR WALL AS REQUIRED FOR NEW
FINISHES
15 CAREFULLY REMOVE EXISTING DOOR AND DOOR HARDWARE. KEEP IN CLEAN, SAFE AREA FOR RE-USE.
DOORS TO BE RE-FINISHED AND RE-LOCATED IN NEW WORK. REMOVE DOOR FRAME - PREP OPENING FOR
INFILL
16 DEMOLISH AND REMOVE PORTION OF EXISTING WALL AS REQUIRED FOR NEW 3'-0" X 7'-0" DOOR IN NEW
WORK.
17 DEMOLISH AND REMOVE 4X4 FLUORESCENT LIGHT FIXTURE. PREP FOR NEW LED LIGHT FIXTURE
18 REMOVE EXISTING EXIT SIGN. REPLACE IN NEW WORK
19 REMOVE EXISTING EMERGENCY LIGHTINING. REPLACE IN NEW WORK.
20 REMOVE EXISTING CARPET IN ENTRY HALL. PREP FLOOR FOR NEW CARPET.
1/8" = 1'-0"D101A3 DEMOLITION FLOOR PLAN
1/8" = 1'-0"D101A1 DEMOLITION CEILING PLAN
PROJECT NORTH
GENERAL NOTES
Mark
Date
Description
DEAN'S OFFICE
164
OFFICE
163A
SECRETARIAL
163M
ASSOC. DEAN
163I
ASSIST. DEAN
163H
OFFICE
163F
OFFICE
163E
OFFICE
163D
OFFICE
163C
OFFICE
163B
CONFERENCE ROOM
163L
OFFICE
163K
NO WORK THIS AREA
NO WORK THIS AREA
NO WORK THIS AREA
ALTERNATE #1:RENOVATIONS TO ROOM 163G. REFER TO ALTERNATE SCHEDULE
OFFICE
136
OFFICE
138
WORK ROOM
163
NO WORK THIS AREA
OFFICE
163G
HALL
100
NO WORK THIS AREA
11
11
11
11
11
11
11
11
11
11
11
11 11
1111
12
12
12
12
12
12
12
13
13
13
11
12
14
15
15
15
16
16
15
15
14
14
14 14
17
14 14
14
17
17
11
12
12 12
12 12
12
12
12 12
17
18
15
19
20
20
20
20
20
20
20
20
20
20 20
2020
20
20
20
20
19
19
22
TYP
1
6"
163A
24
15
17 17
25
25
19
163M
26
27
TYP
28
29
30
3132
11
12
A. REFER TO REFLECTED CEILING PLAN SHEETS FOR CEILING-MOUNTED FIXTURES AND EQUIPMENT. COORDINATE WITH ELECTRICAL.
B. ALL DIMENSIONS ARE TO FACE OF EXISTING WALL UNLESS OTHERWISE NOTED.C. ALL EXISTING CRIMSON ACCENT WALLS WITHIN THE WORK AREA ARE TO BE TOUCHED-UP IN NEW WORK. D. ALL EXISTING CEILING MOUNTED EQUIPMENT REMOVED DURING DEMOLITION IS TO BE RE-INSTALLED IN-PLACE DURING NEW
WORK.E. CONTRACTOR TO FIELD VERIFY THAT ALL EXISTING HM FRAMES HAVE MATCHING PAINT COLOR. CONTRACTOR TO PAINT
UNMATCHING PORTIONS OF HM FRAMES TO MATCH FRAME COLOR THROUGHOUT SUITE.F. CONTRACTOR TO COORDINATE ALL PAINT COLORS, ACCENT COLORS AND ACCENT LOCATIONS WITH NMSU PRIOR TO
COMMENCING THE WORK.
NO WORK THIS AREA
NO WORK THIS AREA
NO WORK THIS AREA
NO WORK THIS AREA
NO WORK THIS AREA
NO WORK THIS AREA
ALTERNATE #1:RENOVATIONS TO ROOM 163G. REFER TO ALTERNATE SCHEDULE
OFFICE
136
OFFICE
138
3' -
9"
6' -
0"
3' -
10
"
EQ EQ EQ EQ
4' -
10
"8
' -
0"
4' -
9"
1
1
1
2
3
2
4
TYP
4
OFFICE
163B
OFFICE
163C
5
5
A
B
6
7
8
B
A
6
B
B A
TYPB
A
B A
OFFICE
163D
OFFICE
163E
9
B
A
BA
OFFICE
163F
OFFICE
163G
A
B
7
7
7
7
7
7
7
7
77
8
8
8
8
8
6
6
8
ASSIST. DEAN
163H
10
TYP
B A
B
A
A B
A
ASSOC. DEAN
163I
TYP
10
TYP
B
A
B
A
B
10
TYP
B
B
A
AA
AA
A
B
SECRETARIAL
163M
8
88
A
B
B
DEAN'S OFFICE
164
A
A
A
B
10
TYP
A
CONFERENCE ROOM
163L
WORK ROOM
163
HALL
100
HALL
102
21
21
21
6
9
6
TYP
6
TYP
6
B
6
23
23
6
4
4
4
7
8
8
OFFICE
163A
TYP
TYP
ACOUSTICAL TILE CEILING - 24" x 48"NEW CEILING TILES -
EXISTING CEILING GRID TO REMAIN -PAINT
EXISTING CEILING TO REMAIN - NO WORK
EXISTING ADHERED ACOUSTICAL TILE CEILING - 12" X 12"-PAINT
HVAC RETURN AIR GRILLE - REF MECHANICAL SHEETS.
HVAC SUPPLY AIR DIFFUSER- REFFER TO SCHEDULE
EXIT LIGHTING - REF ELECTRICAL SHEETS.
2x2 LIGHT FIXTURE - REF ELECTRICAL SHEETS.
2x4 LIGHT FIXTURE - REF ELECTRICAL SHEETS.
RCP LEGENDA. Additive Alternate #1 – Renovations to room 163 G to include:
a. Removal and replacement of existing carpetb. Removal and replacement of existing light fixtures and new LED
fixtures to match the new light fixtures in the suite’s conference room
c. Removal and replacement of the existing HVAC grilles and diffusers to match the new diffusers in the suite’s conference room
d. Removal and replacement of the acoustical ceiling tiles to match the new ceiling tiles in the suite’s conference room. Existing ceiling grid to remain and to receive new paint. Modify ceiling grid as required for new lighting layout.
e. Preparation of existing substrates for new paint throughout U.N.O. New paint to be provided throughout the suite U.N.O.
B. Additive Alternate #2 – Re-finishing of existing closet doorsa. Removal of existing closet doors and door hardware as indicated
on the drawings.b. Strip existing finish coat and stain. Sand surface with fine grit
sandpaper. Re-stain and finish (clear coat) to match door on conference room 163L or as selected by NMSU Architect
ALTERNATE SCHEDULE
N
RE
G
I ST ERED A RCH
I T
EC
T
ST
AT
E
OF NEWMEX
ICORICHARD HAAS
NO. 2530
This document may not be reproduced in whole or part by any means, electronic or otherwise without the explicit written permission of Desert Peak Architects P.C.. All reports, plans, specifications, computer files, field data and other documents and instruments prepared by the Architect as instruments of service shall remain the property of the Architect. The Architect shall retain all common law, statutory, and other reserved rights, including the copyright thereto.
DESERT PEAK ARCHITECTS P.C.311 N MAIN STREETLAS CRUCESNEW MEXICO 88001P. 575.528.0022
SHEET NO.
SHEET TITLE
ISS
UE
:
D
C
B
A
1 3 4 52
WORK AREA
PROJECT NO.206-101
A101
FIRST FLOOR PLAN &
REFLECTED CEILING
PLAN
10/0
7/2
019
DE
AN
'S S
UIT
E R
EN
OV
AT
ION
S
NM
SU
, B
RE
LA
ND
HA
LL
15
25
ST
EW
AR
T S
T.
LA
S C
RU
CE
S, N
M 8
80
03
CO
NS
TR
UC
TIO
N D
OC
UM
EN
TS
10/07/2019
1/8" = 1'-0"A101A2 FIRST FLOOR PLAN
GENERAL NOTES KEYNOTE LEGEND1 SURFACE MOUNTED LIGHT FIXTURE - REFER TO ELECTRICAL
2 EXISTING 12" x 12" ADHERED ACOUSTIC TILE CEILING TO REMAIN. PATCH/REPAIR AS REQUIRED - PAINT IN NEW WORK. COLOR AS
SELECTED BY NMSU ARCHITECT.
3 NEW EXIT SIGN - REFER TO ELECTRICAL
4 NEW EXIT LIGHT - REFER TO ELECTRICAL
5 EXISTING 2' X 2' LED LIGHT FIXTURE TO REMAIN. REMOVE AND REPLACE AS REQUIRED FOR NEW WORK.
6 LIGHT FIXTURE; PROVIDE/REMOVE SEGMENTS OF CEILING GRID TEE AS REQUIRED FOR NEW LIGHTING LAYOUT; PAINT NEW SEGMENTS
TO MATCH EXISTING - REFER TO ELECTRICAL
7 EXISTING CEILING GRID TO REMAIN. PAINT. COLOR AS SELECTED BY NMSU ARCHITECT
8 NEW ACOUSTIC CEILING TILES TO MATCH CEILING TILES IN CONFERENCE ROOM 163L. EXISTING CEILING GRID TO REMAIN
9 RE-LOCATED EXISTING LED LIGHT FIXTURE; CONTRACTOR TO VERIFY COLOR TEMPERATURES OF RE-LOCATED LIGHT FIXTURES ARE THE
SAME AS NEW LED LIGHT FIXTURES; REPLACE EXISTING FIXTURES THAT VARY IN COLOR TEMPERATURE WITH NEW LED LIGHT FIXTURE.
10 LIGHT FIXTURE - REFER TO ELECTRICAL
11 NEW CARPET TILE IN THIS AREA - COLOR AS SELECTED BY NMSU ARCHITECT
12 NEW RUBBER BASE IN THIS AREA - COLOR AS SELECTED BY NMSU ARCHITECT
13 ALTERNATE #2 -STRIP FINISH COAT AND STAIN OFF EXISTING CLOSET DOOR. SAND SURFACE WITH FINE GRIT SANDPAPER. RE-STAIN TO
MATCH DOOR ON CONFERENCE ROOM 163L OR AS SELECTED BY NMSU ARCHITECT
14 STRIP FINISH COAT AND STAIN OFF EXISTING DOOR. SAND SURFACE WITH FINE GRIT SANDPAPER. RE-STAIN TO MATCH DOOR ON
CONFERENCE ROOM 163L OR AS SELECTED BY NMSU ARCHITECT. RE-INSTALL EXISTING DOOR AND DOOR HARDWARE
15 EXISTING CRIMSON ACCENT WALL TO REMAIN. TOUCH-UP PAINT IN NEW WORK.
16 RE-PAINT EXISTING DOOR. COLOR AS SELECTED BY NMSU ARCHITECT
17 EXISTING DOOR TO REMAIN. NO WORK.
18 PAINT WOOD PANELING ABOVE EXISTING DOOR - COLOR AS SELECTED BY NMSU ARCHITECT
19 PROVIDE ROLLER SHADES FOR ALL EAST FACING WINDOWS. FIELD VERIFY WINDOW SIZES.
20 NEW PAINT ON ALL WALLS U.N.O. - COLOR AS SELECTED BY NMSU ARCHITECT - EXISTING CRIMSON ACCENT COLORS TO REMAIN
21 NEW 4' X 4' LED LIGHT FIXTURE. REFER TO ELECTRICAL
22 REPLACE EXISTING ROOM IDENTIFICATION SIGNAGE WITH NEW SIGNAGE PER NMSU STANDARD. PROVIDE BRAILLE @ 60" A.F.F. AND
INTERNATIONAL SYMBOL OF ACCESSIBILITY WHERE REQUIRED
23 NEW EMERGENCY LIGHTING. REFER TO ELECTRICAL
24 INFILL EXISTING OPENING. REFER TO WALL PARTITION TYPES
25 PAINT PORTIONS OF UN-MATCHING EXISTING HOLLOW METAL FRAMES TO MATCH HOLLOW METAL FRAMES THROUGHOUT THE SUITE
26 CRIMSON PAINT ACCENT WALL - COLOR TO BE APPROVED BY NMSU ARCHITECT.
27 DASHED LINES INDICATE FURNITURE (BY OTHERS, N.I.C.)
28 GATE (BY OTHERS). CONTRACTOR TO PROVIDE AND INSTALL GATE HARDWARE. REFER TO SCHEDULE AND SPECIFICATIONS.
29 LOCATION OF EXISTING ADT FOCUS 200P ALARM PANEL. ELECTRIC STRIKE TO BE CONNECTED TO ALARM SYSTEM. REFER TO ELECTRICAL.
30 CONTRACTOR TO PROVIDE AND INSTALL RACEWAYS AND LOW VOLTAGE WIRING THROUGH FURNITURE (FURNITURE BY OTHERS) FOR
ELECTRIC STRIKE. RACEWAYS ARE TO BE INSTALLED ON CLIPS PROVIDED BY FURNITURE MANUFACTURER TO AVOID VOIDING THE
FURNITURE WARRANTY.
31 HOLD-UP BUTTON TO BE MOUNTED ON SIDE OF FURNITURE (HOLD-UP BUTTON AND INSTALLATION BY OTHERS; FURNITURE BY OTHERS)
32 PUSH RELEASE BUTTON FOR GATE ELECTRIC STRIKE TO BE MOUNTED ON UNDERSIDE OF FURNITURE (PUSH RELEASE BUTTON AND
INSTALLATION BY OTHERS; FURNITURE BY OTHERS).
PROJECT NORTH 1/8" = 1'-0"A101
C1 FIRST FLOOR REFLECTED CEILING PLANPROJECT NORTH
DIFFUSER AND GRILLE SCHEDULEType Mark Manufacturer Model Description
A TITUS OMNI SUPPLY DIFFUSER; STANDARD FINISH - #26 WHITE; STEEL CONSTRUCTION; 24" X 24" FACE; LAY-IN; CONTRACTOR TO
FIELD VERIFY REQUIRED NECK SIZE
B TITUS 50F RETURN GRILLE; STANDARD FINISH - #26 WHITE; STEEL CONSTRUCTION; 12" X 24" FACE; 1/2" BLADE SPACING; LAY-IN
ROOM FINISH SCHEDULEROOM ID FLOOR WALLS CEILING
COMMENTSROOM NO ROOM NAME FLOOR BASE NORTH SOUTH EAST WEST MATL
100 HALL CPT RB N/A N/A N/A N/A N/A REPLACE EXISTING CARPET TILE AND BASE BOARDS IN AREA SHOWN.
101 ENTRY HALL CPT RB P P P P ATC EXISTING CEILING GRID TO REMAIN - PAINT
102 WAITING AREA CPT RB P P P P ATC EXISTING CEILING GRID TO REMAIN - PAINT
102 HALL CPT RB P P P P ATC EXISTING CEILING GRID TO REMAIN - PAINT
136 OFFICE CPT RB P P P P ECP EXISTING ADHERED ACOUSTIC CEILING TO REMAIN - PAINT
138 OFFICE CPT RB P P P P ECP EXISTING ADHERED ACOUSTIC CEILING TO REMAIN - PAINT
163A OFFICE CPT RB P P P P ATC EXISTING CEILING GRID TO REMAIN - PAINT
163B OFFICE CPT RB P P P EP ATC EXISTING CEILING GRID TO REMAIN - PAINT ; EXISTING CRIMSON ACCENT COLOR TO REMAIN
163C OFFICE CPT RB P P P P ATC EXISTING CEILING GRID TO REMAIN - PAINT
163D OFFICE CPT RB P P P EP ATC EXISTING CEILING GRID TO REMAIN - PAINT ; EXISTING CRIMSON ACCENT COLOR TO REMAIN
163E OFFICE CPT RB P P P P ATC EXISTING CEILING GRID TO REMAIN - PAINT
163F OFFICE CPT RB P P P EP ATC EXISTING CEILING GRID TO REMAIN - PAINT ; EXISTING CRIMSON ACCENT COLOR TO REMAIN
163G OFFICE CPT RB P P P EP ATC BASE BID: NO WORK THIS AREA. ALTERNATE #1: RENOVATIONS TO ROOM 163G AS INDICATED IN SCHEDULE
163H ASSIST. DEAN CPT RB P P P P ATC EXISTING CEILING GRID TO REMAIN - PAINT
163I ASSOC. DEAN CPT RB P P EP P ATC EXISTING CEILING GRID TO REMAIN - PAINT ; EXISTING CRIMSON ACCENT COLOR TO REMAIN
163K OFFICE CPT RB P P EP P ATC EXISTING CEILING GRID TO REMAIN - PAINT ; EXISTING CRIMSON ACCENT COLOR TO REMAIN
163M SECRETARIAL CPT RB P P P P ATC EXISTING CEILING GRID TO REMAIN - PAINT
164 DEAN'S OFFICE CPT RB P P P P ATC EXISTING CEILING GRID TO REMAIN - PAINT
Mark
Date
Description
A
7'-0
"
3'-0"
1
2"
7'-2
"
2"
3'-4"
FIRST FLOOR0' - 0"
FINISHED FLOOR
CEILING LINE
EXISTING DECK
EACH SIDE
3 5/8" METAL STUD W/ STANDARD GYP - EACH SIDE
TAPE AND TEXTURE TO MATCH EXISTING - PAINT
RESILIENT BASE
GYPSUM BOARD 5/8",STANDARD - TAPE ANDTEXTURE (SANTE FE TEXTURE,TYP) - PAINT
GYPSUM BOARD 5/8",STANDARD - TAPE ANDTEXTURE (SANTE FE TEXTURE,TYP) - PAINT
1
6"
GAP WITH CLIPS ALLOWING
MOVEMENT
3-5/8" METAL STUDS, 16" OCMINIMUM
RE
G
I ST ERED A RCH
I T
EC
T
ST
AT
E
OF NEWMEX
ICORICHARD HAAS
NO. 2530
This document may not be reproduced in whole or part by any means, electronic or otherwise without the explicit written permission of Desert Peak Architects P.C.. All reports, plans, specifications, computer files, field data and other documents and instruments prepared by the Architect as instruments of service shall remain the property of the Architect. The Architect shall retain all common law, statutory, and other reserved rights, including the copyright thereto.
DESERT PEAK ARCHITECTS P.C.311 N MAIN STREETLAS CRUCESNEW MEXICO 88001P. 575.528.0022
SHEET NO.
SHEET TITLE
ISS
UE
:
D
C
B
A
1 3 4 52
PROJECT NO.206-101
A602
WALL PARTITION
TYPES AND
SCHEDULES
10/0
7/2
019
DE
AN
'S S
UIT
E R
EN
OV
AT
ION
S
NM
SU
, B
RE
LA
ND
HA
LL
15
25
ST
EW
AR
T S
T.
LA
S C
RU
CE
S, N
M 8
80
03
CO
NS
TR
UC
TIO
N D
OC
UM
EN
TS
10/07/2019
FIRST FLOOR DOOR AND FRAME SCHEDULEDOOR FRAME MISC
MARK WIDTH HT THK ELEV MATL ELEV MATLHDWSET COMMENTS
163A 3' - 0" 7' - 0" 1 3/4" A SC WD 1 HM 1 RE-FINISH AND RE-LOCATE EXISTING DOOR. NEW FRAME AND NEW HARDWARE
163M 3' - 0" 3' - 6" N/A TBD N/A N/A 2 GATE N.I.C. - GATE HARDWARE PROVIDED AND INSTALLED BY CONTRACTOR.LOW-VOLTAGE WIRING BY OTHERS. CONTRACTOR TO COORDINATE THE WORK WITHOWNER
1/4" = 1'-0"1
DOOR TYPES 1/4" = 1'-0"
2HM FRAME TYPES
ABBREVIATION LEGEND
HM: HOLLOW METALSC WD: SOLID CORE WOOD DOOR (EXISTING)CPT: CARPET TILERB: RUBBER BASEP: PAINTEP: EXISTING CRIMSON ACCENT COLOR TO REMAIN. TOUCH UP PAINTATC: ACOUSTICAL TILE CEILINGECP: EXISTING ADHERED ACOUSTIC CEILING - PAINT
ROOM FINISH SCHEDULEROOM ID FLOOR WALLS CEILING
COMMENTSROOM NO ROOM NAME FLOOR BASE NORTH SOUTH EAST WEST MATL
100 HALL CPT RB N/A N/A N/A N/A N/A REPLACE EXISTING CARPET TILE AND BASE BOARDS IN AREA SHOWN.
101 ENTRY HALL CPT RB P P P P ATC EXISTING CEILING GRID TO REMAIN - PAINT
102 WAITING AREA CPT RB P P P P ATC EXISTING CEILING GRID TO REMAIN - PAINT
102 HALL CPT RB P P P P ATC EXISTING CEILING GRID TO REMAIN - PAINT
136 OFFICE CPT RB P P P P ECP EXISTING ADHERED ACOUSTIC CEILING TO REMAIN - PAINT
138 OFFICE CPT RB P P P P ECP EXISTING ADHERED ACOUSTIC CEILING TO REMAIN - PAINT
163A OFFICE CPT RB P P P P ATC EXISTING CEILING GRID TO REMAIN - PAINT
163B OFFICE CPT RB P P P EP ATC EXISTING CEILING GRID TO REMAIN - PAINT ; EXISTING CRIMSON ACCENT COLOR TO REMAIN
163C OFFICE CPT RB P P P P ATC EXISTING CEILING GRID TO REMAIN - PAINT
163D OFFICE CPT RB P P P EP ATC EXISTING CEILING GRID TO REMAIN - PAINT ; EXISTING CRIMSON ACCENT COLOR TO REMAIN
163E OFFICE CPT RB P P P P ATC EXISTING CEILING GRID TO REMAIN - PAINT
163F OFFICE CPT RB P P P EP ATC EXISTING CEILING GRID TO REMAIN - PAINT ; EXISTING CRIMSON ACCENT COLOR TO REMAIN
163G OFFICE CPT RB P P P EP ATC BASE BID: NO WORK THIS AREA. ALTERNATE #1: RENOVATIONS TO ROOM 163G AS INDICATED IN SCHEDULE
163H ASSIST. DEAN CPT RB P P P P ATC EXISTING CEILING GRID TO REMAIN - PAINT
163I ASSOC. DEAN CPT RB P P EP P ATC EXISTING CEILING GRID TO REMAIN - PAINT ; EXISTING CRIMSON ACCENT COLOR TO REMAIN
163K OFFICE CPT RB P P EP P ATC EXISTING CEILING GRID TO REMAIN - PAINT ; EXISTING CRIMSON ACCENT COLOR TO REMAIN
163M SECRETARIAL CPT RB P P P P ATC EXISTING CEILING GRID TO REMAIN - PAINT
164 DEAN'S OFFICE CPT RB P P P P ATC EXISTING CEILING GRID TO REMAIN - PAINT
1/2" = 1'-0"A602A5 WALL PARTITION TYPES
Mark
Date
Description
J
J
J
J
J
J
J
J
ss
S2
ss
ssS2
ssS2
ssS2
ss
S2
s S2s
s
S2
s
s
S2s
ssS
2
ssS2
JJ
J
J
J
J
J
J
J
J
J
J
J
J
s
s
s
s
s
S2
s
ss
S2
J
J
J
s
S2
s
s
J
s
s
s
s
NO
WORK
THIS
AREA
NO
WORK
THIS
AREA
NO
WORK
THIS
AREA
NO
WORK
THIS
AREA
NO
WORK
THIS
AREA
NO
WORK
THIS
AREA
OFFICE
136
OFFICE
138
OFFICE
163B
OFFICE
163C
OFFICE
163D
OFFICE
163E
OFFICE
163F
OFFICE
163G
ASSIST. DEAN
163H
ASSOC. DEAN
163I
SECRETARIAL
163M
DEAN'S OFFICE
164
CONFERENCE ROOM
163L
WORK ROOM
163
HALL
100
HALL
102
B
BB
B
OFFICE
163K
B
B
B
B
B
B
A
A
A
A
A A
A A
A A
A1
A1
A1
A1
A
A
A1
A1
C
C
C
A2
A2
A2
A2
EMX
EMX
EM
EM
EM
OFFICE
163A
EM
EM
EM
X1
X1
X1
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
EM
Ea
c
E
E
OC1OC1
B
B B
B
C1
Eb
E
X
aa
a a
a
aa
b
b
b
b
b
b
b
c
c
c
c
c
c
c
c
c
c
c
c
E
EMX
3
X1
J
J
S2
SECRETARIAL
J
J
s
sJ
J
N
This document may not be
reproduced in whole or part by any
means, electronic or otherwise
without the explicit written
permission of Desert Peak
Architects P.C.. All reports, plans,
specifications, computer files, field
data and other documents and
instruments prepared by the
Architect as instruments of service
shall remain the property of the
Architect. The Architect shall retain
all common law, statutory, and
other reserved rights, including the
copyright thereto.
DESERT PEAK ARCHITECTS P.C.
1014 SOUTH MAIN STREET
LAS CRUCES
NEW MEXICO 88005
P. 575.528.0022
SHEET NO.
SHEET TITLE
IS
SU
E:
D
C
B
A
1 3 4 52
WORK AREA
PROJECT NO.
206-101
E1.0
FIRST FLOOR PLAN
LIGHTING PLAN
18-11-15
DE
AN
'S
S
UIT
E R
EN
OV
AT
IO
NS
NM
SU
, B
RE
LA
ND
H
ALL
1525 S
TE
WA
RT
S
T.
LA
S C
RU
CE
S, N
M 88003
1/8" = 1'-0"
E1.0
1 FIRST FLOOR REFLECTED CEILING PLAN
EXIT LIGHT FIXTURE, CONNECT TO UNSWITCHED HOT CONDUCTOR.
EMERGENCY LIGHTS FIXTURE, CONNECT TO UNSWITCHED HOT CONDUCTOR.
SINGLE POLE WALL SWITCH, 48" TO TOP OF BOX. UNLESS OTHERWISE NOTED.
THREE-WAY WALL SWITCH, 48" TO TOP OF BOX UNLESS OTHERWISE NOTED.
JUNCTION BOX
RECESSED FIXTURE, LETTER DENOTES TYPE
3
"X1"
"EM"
"G"
FLUORESCENT FIXTURE, LETTER DENOTES TYPE
"A"
ELECTRICAL SYMBOL LEGEND
JUNCTION BOX INSTALLED ABOVE THE CEILING WITH FLEXIBLE CONDUIT
CONNECTION TO LAY-IN FIXTURES. MAXIMUM 6'-0" LENGTH OF CONDUIT
WITH REQUIRED CONDUCTORS ALONG WITH GREEN WIRE GROUND.
ABOVE FINISHED FLOORAFF
BRANCH CIRCUIT IN WALLS OR CEILING.
SYMBOL DESCRIPTION
KEYED NOTE SYMBOL-ELECTRICAL2
COMBINATION EXIT/EMERGENCY LIGHT FIXTURE, CONNECT TO UNSWITCHED
"EMX"
HOT CONDUCTOR.
FLUORESCENT FIXTURE, UPPERCASE LETTER DENOTES FIXTURE TYPE, LOWERCASE
"A" "a"
LETTER DENOTES WHICH SWITCH IS CONTROLLING FIXTURE.
DESCRIPTION & MFR. CAT. No.TYPE LAMPS & WATTS MOUNTING
CREE CR24-40L-35K-10V
A2
A
LED 40 W RECESSED
FIXTURE SCHEDULE
CREE CR24-40L-35K-10V-SMK24
LED 40 W SURFACE MOUNTED
E2.0 LIGHTING PLAN KEYNOTE
1 EXISTING EMERGENCY LIGHT FIXTURE TO BE REPLACED BY
NEW LIGHT FIXTURE. CONNECT NEW FIXTURES TO EXISTING
WIRING.
2 CONTRACTOR TO REPLACE EXISTING SWITHCES AND INSTALL
WALL MOUNTED OCCUPANCY SENSOR DUAL TECHNOLOGY
WATTSTOPPER DSW-311, OR EQUAL. SENSOR TO BE SET FOR
AUTO-ON/AUTO-OFF FUNCTION. AUTO-ON FUNCTION TO BE
SET TO TURN ON ONLY 50% OF TOTAL LIGHTING LEVEL OF
EACH LIGHT FIXTURE. AUTO-OFF FUNCTION TO BE SET TO
TURN OFF LIGHTS AFTER 15 MIN. OF NO MOTION SENSING.
REFER TO DETAIL 1/E2.0 ON THIS SHEET.
3 EXISTING LIGHT FIXTURE TO BE RELOCATED AS SHOWN FROM
OFFICES 163F AND 163G. CONTRACTOR TO RELOCATE ONLY
THE FOUR (4) FIXTURES THAT ARE RATED AT 3500K. THE
OTHER FIXTURES IN ROOM 163F TO BE RETURNED TO OWNER.
4 EXISTING SWITCH TO REMAIN. CONTROL THE NEW THREE
LIGHT FIXTURES IN HALLWAY AS SHOWN. CONNECT TO
EXISTING CIRCUIT CURRENTLY SERVING CORRIDOR.
5 PROVIDE AND INSTALL CEILING MOUNTED DUAL TECHNOLOGY
OCCUPANCY SENSOR WATTSTOPPER DT-335 OR EQUAL.
SENSOR TO BE SET FOR AUTO-ON/AUTO-OFF AND TO BE
PROGRAMMED TO TURN OFF LIGHTS AFTER 15 MIN. OF NO
MOTION SENSING. MAKE CONNECTIONS BETWEEN CEILING
MOUNT SENSORS AND SWITCHES AS NECESSARY. REFER TO
DETAIL 2/E2.0 ON THIS SHEET.
6 CONNECT ALL EMERGENCY LIGHT FIXTURES TO NEW
UNSWITCHED HOT CONDUCTOR SERVING THIS AREA.
7 CONTRACTOR TO PROVIDE AND INSTALL NEW WALL MOUNTED
OCCUPANCY SENSOR DUAL TECHNOLOGY WATTSTOPPER
DSW-311, OR EQUAL. SENSOR TO BE SET FOR
AUTO-ON/AUTO-OFF FUNCTION. AUTO-ON FUNCTION TO BE
SET TO TURN ON ONLY 50% OF EACH LIGHT FIXTURE.
AUTO-OFF FUNCTION TO BE SET TO TURN OFF LIGHTS AFTER
15 MIN. OF NO MOTION SENSING. REFER TO DETAIL 1/E2.0 ON
THIS SHEET.
8 EXISTING SWITCH TO BE REMOVED. CONTRACTOR TO
PROVIDE A STEEL BLANK COVER AND RE-SWITCH NEW
FIXTURES AS SHOWN.
9 CONTRACTOR TO RE-WIRE NEW LIGHT FIXTURES TO EXISTING
CIRCUIT MAINTAINED DURING DEMOLITION.
10 EXISTING LIGHT SWITCH TO BE REMOVED. CONTRACTOR TO
RE-WIRE LIGHT TO NEW SWITCH AS SHOWN AND PROVIDE
BLANK COVER.
11 EXISTING LIGHT SWITCHES TO REMAIN IN SAME BOX AREA AS
SHOWN, BUT REWIRED AS SHOWN IN DETAILS 2/E2.0.
6
1
1
EMDUAL LITE EV4D-02WAL
INCLUDED WALL/CEILING
sOCCUPANCY SENSOR DW-311DIMMER SWITCH WIRING DIAGRAM
1
E1.0
NTS
S2
A.
B.
C.
D.
E.
F.
G.
H.
I.
J.
K.
GENERAL NOTES:
L.
VIOLET
RED
LINE
GROUND
GREEN
GREY
BLACK
DRIVER
OR BALLAST
WHITE
NEUTRAL
YELLOW
(SINGLE-WAY WIRING)
ELECTRICAL INSTALLATION MUST FOLLOW ALL NATIONAL AND
LOCAL ELECTRICAL CODES. INSTALLATION MUST CONFORM TO
THE LOCAL POWER COMPANY'S SPECIFICATIONS.
ALL MATERIALS SHALL BE IN ACCORDANCE WITH THE NATIONAL
ELECTRICAL MANUFACTURERS ASSOCIATION AND SHALL BE
LISTED BY THE U.L.
ELECTRICAL CONTRACTOR IS RESPONSIBLE FOR ALL PERMIT AND
INSPECTION FEES REQUIRED BY THE GOVERNING BODIES.
ELECTRICAL CONTRACTOR MUST COMPLY WITH THE LATEST
A.D.A. REQUIREMENTS.
MINIMUM SIZE CONDUCTORS SHALL BE #12 THW CU. UNLESS
NOTED OR SIZED BY CODE.
ALL WIRING MUST BE IN CONDUIT, INCLUDING ALL L.V. WIRING.
THIN WALL CONDUIT (EMT) CAN BE INSTALLED CONCEALED
ABOVE CEILING, IN FURRED WALLS, AND WALLS EXCEPT WHERE
THOSE WALLS ARE GROUTED SOLID. USE FLEX CONDUIT FOR
MOTORS AND LIGHTING FIXTURES. USE WATER TIGHT FLEX
CONDUIT FOR WATER HEATERS DISPOSALS, EXTERIOR
CONNECTIONS, ETC. BOND ACCORDING TO CODE.
VERIFY LOCATIONS OF ALL ELECTRICAL EQUIPMENT WITH OTHER
TRADES TO AVOID CONFLICTS AND INTERFERENCES.
CONTRACTOR MUST VISIT SITE TO BECOME FAMILIAR WITH
EXISTING CONDITIONS BEFORE BIDDING ON THIS PROJECT.
ELECTRICAL DEVICE INSTALLATION SHALL COMPLY WITH
ACCESSIBILITY CODES ADOPTED FOR NEW MEXICO.
FEEDER, BRANCH CIRCUIT DESIGN, AND INSTALLATION SHALL
COMPLY WITH THE 2019 NEW MEXICO ELECTRICAL CODE
14.10.4.10 (B) (6) AND (C) (2) FOR VOLTAGE DROP.
ABANDONED POWER WIRING WILL BE REMOVED BACK TO THE
SOURCE. THE ACCESSIBLE PORTIONS OF CONDUIT/TUBING AND
EQUIPMENT SHALL BE REMOVED. THE ACCESSIBLE PORTIONS OF
ABANDONED CABLES (VOICE, DATA, VIDEO, ALARM, ETC.) SHALL
BE REMOVED.
ALL ELECTRICAL EQUIPMENT IN FIRE RATED WALLS MUST BE
INSTALLED SO THAT FIRE RATING IS NOT COMPROMISED.
2
2
22
2
2
2
2
7
2
1
2
BCREE CR22-32L-35K-10V
LED 32 W RECESSED
A1CREE CR24-50L-35K-10V
LED 50 W RECESSED
3
3
3
3
*SENSOR TO BE SET TO TURN ON AT 50% OF TOTAL LIGHT LEVEL. THE OTHER SWITCH TO
CONTROL OTHER 50%. SENSOR TO BE SET SO THE LIGHTS TURN OFF AFTER 15 MIN. OF
NO MOTION SENSING.
4
8
4
5 5
CEILING MOUNTEDSENSOR WIRING DIAGRAM #1
OC12
E1.0
NTS
LIGHTING
LOAD
TYPICAL
FIXTURE
LIGHTING
SWITCH
NEUTRAL
HOT
LOAD
GROUND
WATTSTOPPER
DT-335
2
2
6
s
LIGHTING CONTROLS LEGEND
DW-311 OR EQUAL WATTSTOPPER DIMMING WALL SWITCH DUAL TECHNOLOGY, SELF POWERED, 48" TO TOP OF
BOX
DT-355 OR EQUAL WATTSTOPPER CEILING MOUNTED DUAL-TECHNOLOGY, 1000 SQ FT, LINE
VOLTAGE
S2
OC1
NOTES:
1. All sensor locations are approximate, refer to manufacturers installation instructions prior to installation.
2. Ultrasonic ceiling mount sensors should be located a minimum of six feet from HVAC supply/return vents.
3. Contractor is responsible for: proper sensitivity & time delay settings (for non-adaptive products), recommended placement, and field verification of circuits
with in respect to power placement.
4. Sensors mounted over the door must be placed one foot inside the threshold.
5. Contractor is responsible for ensuring that the sensor bill of materials complies with the sensor design and layout specifications.
6. Contractor is responsible for installing equipment in compliance with local code.
7. All sensors to be set to turn off lighting after 15 minutes of no motion sensing.
8. Wall mounted occupancy sensors must not be installed behind doors.
9. Contractor may connect low voltage system in daisy chain to minimize LV cable runs.
MODELDEVICEDESCRIPTION
9
9
4
10
9
9
Mark
Date
Description
NOTES: (1) CONTRACTOR TO VERIFY THE VOLTAGE OF THE EXISTING LIGHTING CIRCUITS (120V OR 277V)
BEFORE ORDERING ANY LIGHT FIXTURES
CFINELITE HTP RSE 4X4 S 835 96 277 SC FC 10 FA50 C1 96
LED 55 W RECESSED
C1FINELITE HTP RSE 2X2 S 835 96 277 SC FC 10 FA50 C1 96
LED 27 W RECESSED
11
9
6
4
9
6
6
6
6
6
6
6
6
2
6
EMXEXITRONIX CLED-U1-WH
INCLUDED WALL/CEILING
X1EXITRONIX 902E U WB RC BA
INCLUDED WALL/CEILING
6
13
12
12 PROVIDE AND INSTALL J-BOX ON WALL AT 18" A.F.F. WITH A 3/4"
CONDUIT WITH PULLSTRING AND BUSHINGS TO J-BOX FOR
SECURITY DOOR MAGNETIC LOCK. J-BOX TO HAVE A BLANK
COVER WITH A 1/2" SUPPLY HOLE ON COVER. REFER TO DETAILS
3/E1.0 AND 4/E1.0 ON THIS SHEET. VERIFY EXACT LOCATION AND
INTERCONNECTION REQUIREMENTS WITH OWNERS SECURITY
CONSULTANT BEFORE DOING ANY WORK.
13 PROVIDE AND INSTALL J-BOX ON LATCH SIDE OF DOOR FOR
FUTURE MAGNETIC LOCK. INSTALL A 3/4" CONDUIT WITH
PULLSTRING AND BUSHING TO J-BOX ON WALL FOR DOOR
CONTROL ACCESS, CONDUIT TO BE RUN BEHIND DESK. SEE
DETAIL 4/E1.0 AND 3/E1.0 ON THIS SHEET. VERIFY EXACT
LOCATION AND INTERCONNECTION REQUIREMENTS WITH
OWNERS SECURITY CONSULTANT BEFORE DOING ANY WORK.
13
12
MAGNETIC GATE DETAIL3
E1.0
NTSMAGNETIC LOCK CONDUT DETAIL4
E1.0
NTS
13
12