Room name 101 A101 1 SIM 1 A101 SIM 133A 1t A4 SYMBOL LEGEND 1 A101 SIM ROOM NAME AND NUMBER DOOR NUMBER WINDOW LETTER ACCESSORY / EQUIPMENT NUMBER SECTION REFERENCE ELEVATION REFERENCE DETAIL REFERENCE LIST OF ABBREVIATIONS A A.C AIR CONDITIONED A.D. AREA DRAINED AFF ABOVE FINISH FLOOR A.H.U. AIR HANDLING UNIT ALT. ALTERNATE ALUM. ALUMINUM AMP., A. AMPERES A.O. ACCESS OPENING A.P.C. ACOUSTICAL PANEL CEILING APPROX. APPROXIMATELY ARCH. ARCHITECTURAL A.T. ASPHALT TILE ACT ACOUSTICAL CEILING TILE B BAL. BALANCE BBT BIO BASED TILE BD. BOARD BLDG. BUILDING BLK. BLANK BM. BEAM BOT. BOTTOM BRG. BEARING B.T.U.H. BRITISH THERMO UNIT/HR. C CAB. CABINET CAP. CAPACITY C/B CIRCUIT BREAKER C.D. CEILING DIFFUSER CEM. CEMENT CER. CERAMIC C.F.M. CUBIC FEET/MINUTE CIRC. CIRCULATING C.J. CONTROL JOINT CK'D CHECKERED CKT. CIRCUIT C CENTERLINE CEIL. CEILING C.L. CLOSET C.M.U. CONCRETE MASONY UNIT C.O. CLEAN OUT COL. COLUMN CONC. CONCRETE COND. CONDENSATE CONN. CONNECTION CONST. CONSTRUCTION CONT. CONTINUOUS CONTR. JT. CONTRACTION JOINT CPT. CARPET C.T. CERAMIC TILE C.T.B. CERAMIC TILE BASE C. TO C. CENTER TO CENTER L D DET. DETAIL DIA. DIAMETER DIFF. DIFFUSER DIM. DIMENSION DISC. DISCONNECT D.J. DUMMY JOINT DN. DOWN DR. DRAIN D.S. DOWN SPOUT DWG. (S) DRAWING(S) E EA. EACH E.C. EMPTY CONDUOT E.F. EXHAUST FAN EL. ELEVATION E.I.F.S. EXTERIOR INSULATION FINISH SYSTEM ELEC. ELECTRIC E.P. EPOXY PAINT EQUIP. EQUIPMENT E.W.C. ELECTRIC WATER COOLER EXH. EXHAUST EXP. JT. EXPANSION JOINT EXT. EXTERIOR EXIST. EXISTING F F.A. FIRE ALARM F.C. FLEXIBLE CONNECTION F.D. FLOOR DRAIN F.E.C. FIRE EXTINGUISHER CABINET FIN. FINISH FL. FLOOR FRP. FIBERGLASS REINFORCD POLYESTER PANEL FT. FOOT-FEET FTG. FOOTING G GA. GAUGE GAL. GALLON GALV. GALVANIZED G.L. GLASS GND GROUND GOV'T GOVERNMENT G.P.H. GALLONS/HOUR G.P.M. GALLONS/MIN. GR. GRILLE G.W.B. GYPSUM WALL BOARD GYP. GYPSUM H H.B. HOSE BIBB H.C. HOLLOW CORE HT. HEIGHT H.M. HOLLOW METAL H.P. HORSE POWER HR. HOUR HTG. HEATING HTR HEATER H.&V. HEATING & VENTILATING HW. HARDWARE HYD. HYDRANT I I.D. INSIDE DIAMETER I.E. INVERT IN. INCHES INCAND. INCANDESCENT INSUL. INSULATION INT. INTERIOR J J.B. JUNCTION BOX JCT. JUNCTION JT. JOINT K KVA KILOVOLT AMPERE KW KILOWATT L L.B.# POUND LG. LONG L.P. LIGHTING PANEL LTG. LIGHTING LVT LUXURY VINYL TILE M M. MOTOR MAINT. MAINTENANCE MAX. MAXIMUM MCT MARMOLEUM COMPOSITE TILE M.D.P. MAIN DISTRIBUTION PANEL MECH. MECHANICAL MTL. METAL MIN. MINIMUM MISC. MISCELLANEOUS M.O. MASONRY OPENING M.T. METAL THRESHOLD MTD. MOUNTED MTG. MOUNTING M.V. MECHANICAL VENTILATION M.G.T. MATT GLAZE TILE MGWB MOISTURE RESISTANT GYPSUM WALL BOARD N N.A. NOT APPLICABLE N.I.C. NOT IN CONTRACT NO. NUMBER O O.A. OUTDOOR AIR O.C. ON CENTER O.D. OUTSIDE DIAMETER O.H. OVERHEAD OL. OVERLOAD OPNG. OPENING OPP. OPPOSITE O.S. OPEN STRUCTURE O.S.D. OPEN SIGHT DRAIN P P. PAPER PART. PARTITION PER. PERIMETER P , PL. PLATE PLAS. PLASTER PLBG. PLUMBING PLYW'D PLYWOOD PMP PERMANUFACTURED METAL WALL PANEL PNL. PANEL PRESS. PRESSURE PSF POUNDS/SQUARE FOOR PSI POUNDS/SQUARE INCH PSIG POUNDS/SQUARE IN GAGE PT. POINT PNT. PAINT Q QTR. QUARTER QUAN. QUANTITY QT QUARRY TILE R R. RISER R.A. RETURN AIR RAD. RADIUS RB RUBBER RD. ROUND REC'D RECESSED RECIRC. RECIRCULATING RECP. RECEPTACLE REINF. REINFORCING REQ. REQUIRED RET. RETURN R.G. RETURN GRILLE RM. ROOM R.M.G. REINFORCED MASONRY GROUT R.P.M. REVOLUTION/MINUTE S S. SUPPLY S.A. SUPPLY AIR S.A.T. SUSPENDED ACOUSTICAL TILE SCH. SCHEDULE SECT. SECTION SERV. SERVICE S.G. SEMIGLOSS SHT. SHEET S.J. SLIP JOINT SPEC. SPECIFICATIONS SQ.FT. SQUARE FEET ST. STEEL STOR. STORAGE STRUC STRUCTURAL SUSP. SUSPENDED S.V. SHEET VINYL SW. SWITCH S.C. SCALED CONCRETE T T. TOILET TEL. TELEPHONE TEMP. TEMPERATURE THK. THICKNESS THD. THRESHOLD TOIL. TOILET TYP. TYPICAL V V. VOLT V.C.G. VINYL COVERED GYPSUM CEILING TILE VCT VINYL COMPOSITION TILE V.T. VINYL TILE VENT. VENTILATION VERT. VERTICAL VTR. VENT THRU ROOF W W. WATT W.B. WALL BASE W/ WITH WD. WOOD W.D. WINDOW DIMENSION WF WIDE FLANGE W.G. WATER GAGE WP. WEATHERPROOF WTR. WATER W.W.F. WELDED WIRE FABRIC L PROJECT INFORMATION A. TYPE OF CONSTRUCTION: RENOVATION B. FACILITY NAME CHILD DEVELOPMENT & LITERACY CENTER C. FACILITY ADDRESS 106 CHANTICLEER DR. EAST, CONWAY, SC 29526 D. COUNTY HORRY COUNTY E. LOCAL FIRE DEPARTMENT Horry County Fire/Rescue F. WATER SUPPLY Conway Water & Sewer District G. BUILDING INSPECTION OSE -State Fire Marshal DEPARTMENT H. ARCHITECT SGA ARCHITECTURE, LLC. 8263 Ocean Hwy. Pawleys Island, South Carolina 29585 Steve Goggans, AIA, LEED AP LIST OF DRAWINGS GENERAL G000 G001 G002 COVER SHEET LIFE SAFETY LIFE SAFETY LANDSCAPE ASD101 AS101 DEMOLITION ARCHITECTURAL PLAN ARCHITECTURAL SITE PLAN ARCHITECTURAL A002 A003 D101 A101 A101A A102 A121 A352 A401 A701 A702 SITE DETAILS PARTITION TYPES DEMOLITION FIRST PLAN FIRST FLOOR PLAN FINISH FLOOR PLAN SECOND FLOOR PLAN REFLECTED CEILING PLAN -FIRST FLOOR MISCELLANEOUS DETAILS DOOR AND WINDOW SCHEDULES AND DETAILS INTERIOR ELEVATIONS INTERIOR ELEVATIONS & CASEWORK LIST OF DRAWINGS CONT. PLUMBING P001 PD101 P100 P101 P201 P301 P401 PLUMBING NOTES & SYMBOLS PLUMBING DEMOLITION PLAN PLUMBING SANITARY VENT PLAN PLUMBING DOMESTIC PLAN PLUMBING ISOMETIC DIAGRAM PLUMBING DETAILS PLUMBING SCHEDS. ELECTRICAL M001 MD101 M101 M201 M301 M302 M401 MECHANICAL NOTES & SYMBOLS MECHANICAL DEMOLITION PLAN MECHANICAL PLAN MECHANICAL CONTROLS MECHANICAL DETAILS MECHANICAL DETAILS MECHANICAL SCHEDS. MECHANICAL E001 E002 ED101 E101 ED201 E201 ED301 E301 E302 E401 E501 E601 E602 ELECTRICAL NOTES & SYMBOLS ELECTRICAL NOTES & SYMBOLS ELECTRICAL DEMOLITION PLAN POWER PLAN LIGHTING DEMOLITION PLAN LIGHTING PLAN SPECS. SYSTEMS DEMOLITION PLAN SPECIAL SYSTEMS PLAN SPECIAL SYSTEMS SECOND FLOOR ELECTRICAL DETAILS ELECTRICAL ONE-LINE DIAGRAMS LIGHTING FIXTURE SCHEDULE PANELBOARD SCHEDULES Pawleys Island / Charleston S R A G I CH TEC U T RE COASTAL CAROLINA UNIVERSITY CHILD DEVELOPMENT & LITERACY CENTER RENOVATION Notes: Revisions: 106 CHANTICLEER DR. EAST CONWAY, SC 29526 Owner: COASTAL CAROLINA UNIVERSITY # H17-N104-CB Individual Seal Corporate Seal of COPYRIGHT 2018 ALL RIGHTS RESERVED PRINTED OR ELECTRONIC DRAWINGS AND DOCUMENTATION MAY NOT BE REPRODUCED IN ANY FORM WITHOUT WRITTEN PERMISSION FROM SGA ARCHITECTURE MEMBERS OF THE AMERICAN INSTITUTE OF ARCHITECTS Job Number: 17002 Date: 02/08/2018 Drawn by: HK, GH Checked by: SG 8263 Ocean Hwy. PO Box 1859 Pawleys Island, SC 29585 Phone: (843) 237-3421 Fax: (843) 237-1992 www.SGAarchitecture.com 5 5 4 3 2 1 4 3 2 1 A B C D E F Architect: BID SET 2/8/2018 9:26:26 AM G000 BID SET COVER SHEET 2 CHILD DEVELOPMENT & LITERACY CENTER CCU CHILD DEVELOPMENT AND LITERACY CENTER -RENOVATION 106 CHANTICLEER DR. E. CONWAY, SC 29526 OSE BID SET 01/26/18 VICINITY MAP PROJECT MAP N N REV. # Description Date

CCU CHILD DEVELOPMENT AND...architectural site plan architectural a002 a003 d101 a101 a101a a102 a121 a352 a401 a701 a702 site details partition types demolition first plan first floor

  • Upload
    others

  • View
    1

  • Download
    0

Embed Size (px)

Citation preview

Page 1: CCU CHILD DEVELOPMENT AND...architectural site plan architectural a002 a003 d101 a101 a101a a102 a121 a352 a401 a701 a702 site details partition types demolition first plan first floor

Room name101

A1011

SIM

1A101

SIM

133A

1t

A4

SYMBOL LEGEND

1A101

SIM

ROOM NAME AND NUMBER

DOOR NUMBER

WINDOW LETTER

ACCESSORY / EQUIPMENT NUMBER

SECTION REFERENCE

ELEVATION REFERENCE

DETAIL REFERENCE

LIST OF ABBREVIATIONS

AA.C AIR CONDITIONEDA.D. AREA DRAINEDAFF ABOVE FINISH FLOORA.H.U. AIR HANDLING UNITALT. ALTERNATEALUM. ALUMINUMAMP., A. AMPERESA.O. ACCESS OPENINGA.P.C. ACOUSTICAL PANEL CEILINGAPPROX. APPROXIMATELYARCH. ARCHITECTURALA.T. ASPHALT TILEACT ACOUSTICAL CEILING TILE

BBAL. BALANCEBBT BIO BASED TILEBD. BOARDBLDG. BUILDINGBLK. BLANKBM. BEAMBOT. BOTTOMBRG. BEARINGB.T.U.H. BRITISH THERMO UNIT/HR.

CCAB. CABINETCAP. CAPACITYC/B CIRCUIT BREAKERC.D. CEILING DIFFUSERCEM. CEMENTCER. CERAMICC.F.M. CUBIC FEET/MINUTECIRC. CIRCULATINGC.J. CONTROL JOINTCK'D CHECKEREDCKT. CIRCUITC CENTERLINECEIL. CEILINGC.L. CLOSETC.M.U. CONCRETE MASONY UNITC.O. CLEAN OUTCOL. COLUMNCONC. CONCRETECOND. CONDENSATECONN. CONNECTIONCONST. CONSTRUCTIONCONT. CONTINUOUSCONTR. JT. CONTRACTION JOINTCPT. CARPETC.T. CERAMIC TILEC.T.B. CERAMIC TILE BASEC. TO C. CENTER TO CENTER

L

DDET. DETAILDIA. DIAMETERDIFF. DIFFUSERDIM. DIMENSIONDISC. DISCONNECTD.J. DUMMY JOINTDN. DOWNDR. DRAIND.S. DOWN SPOUTDWG. (S) DRAWING(S)

EEA. EACHE.C. EMPTY CONDUOTE.F. EXHAUST FANEL. ELEVATIONE.I.F.S. EXTERIOR INSULATION

FINISH SYSTEMELEC. ELECTRICE.P. EPOXY PAINTEQUIP. EQUIPMENTE.W.C. ELECTRIC WATER COOLEREXH. EXHAUSTEXP. JT. EXPANSION JOINTEXT. EXTERIOREXIST. EXISTING

FF.A. FIRE ALARMF.C. FLEXIBLE CONNECTIONF.D. FLOOR DRAINF.E.C. FIRE EXTINGUISHER CABINETFIN. FINISHFL. FLOORFRP. FIBERGLASS REINFORCD POLYESTER

PANELFT. FOOT-FEETFTG. FOOTING

GGA. GAUGEGAL. GALLONGALV. GALVANIZEDG.L. GLASSGND GROUNDGOV'T GOVERNMENTG.P.H. GALLONS/HOURG.P.M. GALLONS/MIN.GR. GRILLEG.W.B. GYPSUM WALL BOARDGYP. GYPSUM

HH.B. HOSE BIBBH.C. HOLLOW COREHT. HEIGHTH.M. HOLLOW METALH.P. HORSE POWERHR. HOURHTG. HEATINGHTR HEATERH.&V. HEATING & VENTILATINGHW. HARDWAREHYD. HYDRANT

II.D. INSIDE DIAMETERI.E. INVERTIN. INCHESINCAND. INCANDESCENTINSUL. INSULATIONINT. INTERIOR

JJ.B. JUNCTION BOXJCT. JUNCTIONJT. JOINT

KKVA KILOVOLT AMPEREKW KILOWATT

LL.B.# POUNDLG. LONGL.P. LIGHTING PANELLTG. LIGHTINGLVT LUXURY VINYL TILE

MM. MOTORMAINT. MAINTENANCEMAX. MAXIMUMMCT MARMOLEUM COMPOSITE TILEM.D.P. MAIN DISTRIBUTION PANELMECH. MECHANICALMTL. METALMIN. MINIMUMMISC. MISCELLANEOUSM.O. MASONRY OPENINGM.T. METAL THRESHOLDMTD. MOUNTEDMTG. MOUNTINGM.V. MECHANICAL VENTILATIONM.G.T. MATT GLAZE TILEMGWB MOISTURE RESISTANT GYPSUM

WALL BOARDNN.A. NOT APPLICABLEN.I.C. NOT IN CONTRACTNO. NUMBER

OO.A. OUTDOOR AIRO.C. ON CENTERO.D. OUTSIDE DIAMETERO.H. OVERHEADOL. OVERLOADOPNG. OPENINGOPP. OPPOSITEO.S. OPEN STRUCTUREO.S.D. OPEN SIGHT DRAIN

PP. PAPERPART. PARTITIONPER. PERIMETERP , PL. PLATEPLAS. PLASTERPLBG. PLUMBINGPLYW'D PLYWOODPMP PERMANUFACTURED METAL WALL

PANELPNL. PANELPRESS. PRESSUREPSF POUNDS/SQUARE FOORPSI POUNDS/SQUARE INCHPSIG POUNDS/SQUARE IN GAGEPT. POINTPNT. PAINT

QQTR. QUARTERQUAN. QUANTITYQT QUARRY TILE

RR. RISERR.A. RETURN AIRRAD. RADIUSRB RUBBERRD. ROUNDREC'D RECESSEDRECIRC. RECIRCULATINGRECP. RECEPTACLEREINF. REINFORCINGREQ. REQUIREDRET. RETURNR.G. RETURN GRILLERM. ROOMR.M.G. REINFORCED MASONRY GROUTR.P.M. REVOLUTION/MINUTE

SS. SUPPLYS.A. SUPPLY AIRS.A.T. SUSPENDED ACOUSTICAL TILESCH. SCHEDULESECT. SECTIONSERV. SERVICES.G. SEMIGLOSSSHT. SHEETS.J. SLIP JOINTSPEC. SPECIFICATIONSSQ.FT. SQUARE FEETST. STEELSTOR. STORAGESTRUC STRUCTURALSUSP. SUSPENDEDS.V. SHEET VINYLSW. SWITCHS.C. SCALED CONCRETE

TT. TOILETTEL. TELEPHONETEMP. TEMPERATURETHK. THICKNESSTHD. THRESHOLDTOIL. TOILETTYP. TYPICAL

VV. VOLTV.C.G. VINYL COVERED GYPSUM CEILING TILEVCT VINYL COMPOSITION TILEV.T. VINYL TILEVENT. VENTILATIONVERT. VERTICALVTR. VENT THRU ROOF

WW. WATTW.B. WALL BASEW/ WITHWD. WOODW.D. WINDOW DIMENSIONWF WIDE FLANGEW.G. WATER GAGEWP. WEATHERPROOFWTR. WATERW.W.F. WELDED WIRE FABRIC

L

PROJECT INFORMATIONA. TYPE OF CONSTRUCTION: RENOVATION

B. FACILITY NAME CHILD DEVELOPMENT & LITERACY CENTER

C. FACILITY ADDRESS 106 CHANTICLEER DR. EAST, CONWAY, SC 29526

D. COUNTY HORRY COUNTY

E. LOCAL FIRE DEPARTMENT Horry County Fire/Rescue

F. WATER SUPPLY Conway Water & Sewer District

G. BUILDING INSPECTION OSE -State Fire MarshalDEPARTMENT

H. ARCHITECT SGA ARCHITECTURE, LLC.8263 Ocean Hwy.Pawleys Island, South Carolina 29585Steve Goggans, AIA, LEED AP

LIST OF DRAWINGSGENERALG000G001G002

COVER SHEETLIFE SAFETYLIFE SAFETY

LANDSCAPEASD101AS101

DEMOLITION ARCHITECTURAL PLANARCHITECTURAL SITE PLAN

ARCHITECTURALA002A003D101A101A101AA102A121

A352A401A701A702

SITE DETAILSPARTITION TYPESDEMOLITION FIRST PLANFIRST FLOOR PLANFINISH FLOOR PLANSECOND FLOOR PLAN REFLECTED CEILING PLAN -FIRST FLOOR

MISCELLANEOUS DETAILS DOOR AND WINDOW SCHEDULES AND DETAILSINTERIOR ELEVATIONSINTERIOR ELEVATIONS & CASEWORK

LIST OF DRAWINGS CONT.PLUMBINGP001PD101P100P101P201P301P401

PLUMBING NOTES & SYMBOLSPLUMBING DEMOLITION PLANPLUMBING SANITARY VENT PLANPLUMBING DOMESTIC PLANPLUMBING ISOMETIC DIAGRAMPLUMBING DETAILSPLUMBING SCHEDS.

ELECTRICAL

M001MD101M101M201M301M302M401

MECHANICAL NOTES & SYMBOLSMECHANICAL DEMOLITION PLANMECHANICAL PLANMECHANICAL CONTROLSMECHANICAL DETAILSMECHANICAL DETAILS MECHANICAL SCHEDS.

MECHANICAL

E001E002ED101E101ED201E201ED301E301E302E401E501E601E602

ELECTRICAL NOTES & SYMBOLSELECTRICAL NOTES & SYMBOLSELECTRICAL DEMOLITION PLANPOWER PLANLIGHTING DEMOLITION PLANLIGHTING PLANSPECS. SYSTEMS DEMOLITION PLANSPECIAL SYSTEMS PLANSPECIAL SYSTEMS SECOND FLOORELECTRICAL DETAILSELECTRICAL ONE-LINE DIAGRAMSLIGHTING FIXTURE SCHEDULEPANELBOARD SCHEDULES

Pawleys Island / Charleston

S RAG IC H T E C UT R E

COASTALCAROLINA

UNIVERSITYCHILD

DEVELOPMENT& LITERACY

CENTERRENOVATION

Notes:

Revisions:

106 CHANTICLEER DR. EASTCONWAY, SC 29526

Owner:

COASTAL CAROLINA UNIVERSITY# H17-N104-CB

Individual Seal

Corporate Seal

of

COPYRIGHT 2018 ALL RIGHTS RESERVEDPRINTED OR ELECTRONIC DRAWINGS ANDDOCUMENTATION MAY NOT BE REPRODUCEDIN ANY FORM WITHOUT WRITTENPERMISSION FROM SGA ARCHITECTURE

MEMBERS OFTHE AMERICAN INSTITUTE OF ARCHITECTS

Job Number: 17002Date: 02/08/2018Drawn by: HK, GHChecked by: SG

8263 Ocean Hwy.PO Box 1859Pawleys Island, SC 29585Phone: (843) 237-3421Fax: (843) 237-1992www.SGAarchitecture.com

5

5

4321

4321

A

B

C

D

E

F

Architect:

BID SET

2/8/

2018

9:2

6:26

AM

G000BID SET

COVER SHEET

2CHILD DEVELOPMENT & LITERACYCENTER

CCU CHILD DEVELOPMENT ANDLITERACY CENTER -RENOVATION

106 CHANTICLEER DR. E.CONWAY, SC 29526

OSE BID SET01/26/18

VICINITY MAP PROJECT MAPNN

REV. # Description Date

Page 2: CCU CHILD DEVELOPMENT AND...architectural site plan architectural a002 a003 d101 a101 a101a a102 a121 a352 a401 a701 a702 site details partition types demolition first plan first floor

UP

UPFAAPF.E (E)

F.E

(E)

F.E (E)

F.E (N)

F.E

(N)

F.E (N)

1 2 3 4 5 6 7

8

9

10

11

12

TRAVEL DIST. -145'-11"

COMMON PATH OF TRAVEL= 38'-2"

7

170

7

4 4

46

6

30

170

1 1

11

226

19

1

17

38

340

16

39

340

20

340

1

55

1

6

EXISTING FIRE EXTINGUISHER

EXISTINGFIREEXTINGUISHER

EXISTING RATED CEILINGAT CORRIDORSPATCH & REPAIR

EXISTING RATED CEILINGAT CORRIDORSCONFIRM EXTENT PATCH& REPAIR

PROVIDE 1 HR RATED CEILING AT CORRIDOR

ETR

ETR

ETR

ETR

PROPOSED 1HOUR CEILING

DEAD END CORRIDOR

10' - 10"

CODES AND REGULATIONSCODES COMPLIANCE REVIEW AND RELATED INFORMATION (AS OF DATE 07/01/16)PROJECT DESIGN IN ACCORDANCE WITH:

A. South Carolina Building Code, 2015 EditionB. The International Plumbing Code, 2015 Edition with modificationsC. The International Mechanical Code, 2015 Edition with modificationsD. The International Fuel Gas Code, 2015 Edition with modificationsE. The International Fire Code, 2015 Edition with modificationsF. The National Electrical Code NFIPA 70, 2014 EditionG. The National Electrical Safety Code ANSI- C2-2012 EditionH. National Fire Protection Association NFPA 58, 2012 EditionI. International Energy Conservation Code, 2009 Edition with modificationsJ. ASHRAE/IESNA 90.1-2004 & 2007, Energy Efficient Design of New BuildingsK. ANSI/ASHRAE 62-2007,Ventilation for Acceptable Indoor Air QualityL. ICC/ANSI-A117.1-2009, Providing Accessibility and Usability for Physically Handicapped PeopleM. Americans with Disabilities Act (ADA), latest editionN. Erosion and Sediment Reduction and Stormwater Management Regulations

(R.72-101 through R.72-108, latest revision)O. South Carolina Elevator Code and Regulations, latest edition

LEGEND:

ILLUMINATED EXIT SIGN - REFER TO ELECTRICAL

1 HOUR RATED PARTITION

PORTABLE FIRE EXTINGUISHER FOR ORDINARY (Moderate) HAZARD OCCUPANCY (CHAPTER 9)

FIRE HAZARD MIN. RATED MAX. FLOOR MAX. TRAVEL NOTESCLASS EXTINGUISHER COVERAGE AREA DISTANCE

FE-1 CLASS A 2-A 3,000 sf 75' Ordinary (Moderate) Hazard Occupancy

TRAVEL DISTANCE (CHAPTER 10 - TABLE 1017.2)

OCCUPANCY MAX. TRAVEL NOTES

(B) BUSINESS & (S) STORAGE 200'-0" 1. SEE SHEET G001 FOR MAXIMUM TRAVEL DISTANCE PROVIDED(E) EDUCATION 200'-0" 2. SEE SHEET G001 FOR MAXIMUM TRAVEL DISTANCE PROVIDED

COMMON PATH OF TRAVEL (CHAPTER 10 - TABLE 1006.2)

OCCUPANCY MAX. TRAVEL NOTES

(B) BUSINESS & (S) STORAGE 100'-0" 1. SEE SHEET G001 FOR COMMON PATH OF TRAVEL PROVIDED(E) EDUCATION 75'-0" 2. SEE SHEET G001 FOR COMMON PATH OF TRAVEL PROVIDED

XXXXX

EGRESS DESIGN LOAD

ALLOWABLE CAPACITY

CORRIDORS (CHAPTER 10 - TABLE 1020.1 & SECTION 1020.4 DEAD ENDS)

OCCUPANCY FIRE RESISTANCE RATING DEAD END ALLOWED

(B) BUSINESS & (E) EDUCATION 1 HR 20FT (NON-SPRINKLED)

EGRESS WIDTH (CHAPTER 10 - SEC. 1005.3.1 AND SEC. 1005.3.2)

MEANS OF EGRESS INCHES PER OCC. TOTAL OCC. LOAD REQUIRED INCHES ACUTAL INCHESSIZING REQUIREDSTAIRS SEC. 0.3 10 32 INCHES PER IBC 72 INCHES1005.3.1.

OTHER EGRESS 0.2 124 32 INCHES PER IBC 256 INCHESCOMPONENTS

XX ROOM EGRESS DESIGN LOAD EMERGENCY BALLAST - REFER TO ELECTRICAL

F.E FIRE EXTINGUISHER, PROVIDE NEW CABINET AT EXISTING FIRE EXTINGUISHER

F.E (N) NEW FIRE EXTINGUISHER(N) NEW PER SPECIIFICATIONSETR EXISTING TO REMAIN

PROJECT DESCRIPTIONPROJECT IS LOCATED IN CONWAY, SC ON THE COASTAL CAROLINA UNIVERSITY CAMPUS. THE PROJECT IS A MINIMALRENOVATION OF THE EXISTING BUILDING TO ACCOMODATE A CHILD DEVELOPMENT & LITERACY CENTER AS WELL AS A NEWPLAYGROUND LOCATED IN THE EXISTING PARKING LOT. THE EXISTING CALL CENTER IN THE BUILDING WILL HAVE MINIMALWORK TO ACCOMODATE ADJUSTED EGRESS ROUTES. EXISTING MECHANICAL, ELECTRICAL/IT, AND RESTROOMS WILL REMAINUNTOUCHED BY RENOVATION. NEW CODE COMPLIANT UNISEX RESTROOMS WILL BE INCORPORATED INTO THE CHILDDEVELOPMENT CENTER. MINIMAL INTERIOR WORK WILL REQUIRE SOME WALLS TO BE DEMOLISHED AND RELOCATED TOACCOMODATE THE NEW PROGRAM. NEW PAINT, CEILINGS, FLOORING AND EQUIPMENT WILL BE PROVIDED IN CHILDDEVELOPMENT & LITERACY ROOMS AS WELL AS THE ADMINISTRATIVE SUPPORT AREAS FOR THE CENTER.

GENERAL NOTES- CODE ANALYSIS:

1. ON PENETRATING RATED WALLS: PRIOR TO PENETRATING AND SEALING RATED WALLS. CONTRACTOR AND SUBS SHALLSUBMIT CUT SHEETS DETAILING THE PENETRATION "SYSTEM" TO BE USED TO MAINTAIN FIRE-RATED INTEGRITY OF THE

WALLS. DURING STATE INSPECTIONS, CONTRACTOR AND SUBS SHALL HAVE, IN THEIR POSSESSION, CUT SHEETS OF THEPENETRATION SYSTEMS FOR REVIEW BY THE STATE INSPECTOR.

2. SEE PARTITION SCHEDULE A003 FOR PARTITION TYPES. ALL PARTITIONS ARE W68 UNLESS NOTED OTHERWISE.

3. IN ACCORDANCE WITH THE INTERNATIONAL BUILDING CODE, LABEL ALL FIRE-RATED WALLS AND SMOKESTOP PARTITIONSABOVE CEILINGS AND IN CONCEALED SPACES WITH 1 1/2" HIGH STENCILED RED LETTERS AS IN THE FOLLOWING,EXAMPLES:"1-HOUR RATED WALL - PROTECT ALL OPENINGS""3-HOUR RATED WALL - PROTECT ALL OPENINGS"

(THE ABOVE INFORMATION IS TO BE STENCILED EVERY 20'-0" AND VISIBLE FROM ANY POINT ALONG ALL RATED WALLSWITH THE REQ'D FIRE RATING SHOWN.)

4. PROJECT PHASING:1) PROVIDE TEMPORARY EGRESS

A) INSTALL DUST WALLS AS NEEDED, BARRICADES, SIGNAGE, ETC.B) INSTALL CONSTRUCTION YARD FENCINGC) INSTALL SILT FENCE

2) COMENCE WITH UTILITY SERVICE DISCONNECT AS DETERMINED.A)SPECIFIED DEMOLITIONB) COMMENCE REMODEL,C) FURNISH AND INSTALL PROPOSED MATERIALS, SYSTEMS AND FINISHES.

3) INSTALL NEW WALKS, LANDSCAPING, PARKING STRIPING AND FENCING

COMPLETION OF ALL WORK

01/22/18 Pawleys Island / Charleston

S RAG IC H T E C UT R E

COASTALCAROLINA

UNIVERSITYCHILD

DEVELOPMENT& LITERACY

CENTERRENOVATION

Notes:

Revisions:

106 CHANTICLEER DR. EASTCONWAY, SC 29526

Owner:

COASTAL CAROLINA UNIVERSITY# H17-N104-CB

Individual Seal

Corporate Seal

of

COPYRIGHT 2018 ALL RIGHTS RESERVEDPRINTED OR ELECTRONIC DRAWINGS ANDDOCUMENTATION MAY NOT BE REPRODUCEDIN ANY FORM WITHOUT WRITTENPERMISSION FROM SGA ARCHITECTURE

MEMBERS OFTHE AMERICAN INSTITUTE OF ARCHITECTS

Job Number: 17002Date: 02/08/2018Drawn by: HK, GHChecked by: SG

8263 Ocean Hwy.PO Box 1859Pawleys Island, SC 29585Phone: (843) 237-3421Fax: (843) 237-1992www.SGAarchitecture.com

5

5

4321

4321

A

B

C

D

E

F

Architect:

BID SET

2/8/

2018

9:2

6:30

AM

G001BID SET

BUILDING CODEANALYSIS

1/8" = 1'-0"1BUILDING CODE ANALYSIS -FIRSTFLOOR

REV. # Description Date

Page 3: CCU CHILD DEVELOPMENT AND...architectural site plan architectural a002 a003 d101 a101 a101a a102 a121 a352 a401 a701 a702 site details partition types demolition first plan first floor

Pawleys Island / Charleston

S RAG IC H T E C UT R E

COASTALCAROLINA

UNIVERSITYCHILD

DEVELOPMENT& LITERACY

CENTERRENOVATION

Notes:

Revisions:

106 CHANTICLEER DR. EASTCONWAY, SC 29526

Owner:

COASTAL CAROLINA UNIVERSITY# H17-N104-CB

Individual Seal

Corporate Seal

of

COPYRIGHT 2018 ALL RIGHTS RESERVEDPRINTED OR ELECTRONIC DRAWINGS ANDDOCUMENTATION MAY NOT BE REPRODUCEDIN ANY FORM WITHOUT WRITTENPERMISSION FROM SGA ARCHITECTURE

MEMBERS OFTHE AMERICAN INSTITUTE OF ARCHITECTS

Job Number: 17002Date: 02/08/2018Drawn by: HK, GHChecked by: SG

8263 Ocean Hwy.PO Box 1859Pawleys Island, SC 29585Phone: (843) 237-3421Fax: (843) 237-1992www.SGAarchitecture.com

5

5

4321

4321

A

B

C

D

E

F

Architect:

BID SET

2/8/

2018

9:2

6:33

AM

G002BID SET

BUILDING CODEANALYSIS

REV. # Description Date

Page 4: CCU CHILD DEVELOPMENT AND...architectural site plan architectural a002 a003 d101 a101 a101a a102 a121 a352 a401 a701 a702 site details partition types demolition first plan first floor

2'-10"

1

SELECTIVELY DEMOLISH SIDE WALKTO ACCOMODATE NEW RAMP-PATCH AND REPAIR CONCRETE AND PAVEMENTDAMAGED BY CONSTRUCTION TO MATCH EXISTINGCONDITIONS/MATERIALS, SEE 2/A002

EXISTING ADA RAMP

MAINTAIN PAVEMENTREMOVE EXISTING STRIPING MAINTAIN PAVEMENT

REMOVE EXISTING STRIPING

DO

WN

TO BASE, V.I.F.

REM

OVE STR

IPING

AND

PAVEMEN

T

DO

WN

TO

BAS

E

REM

OVE

EXI

STIN

G P

AVEM

ENT

V.I.F

----

EXISTINGADA RAMP

(E) TRANS.

(E). HVAC

15' - 0" 10' - 0"

KEY NOTES:

1. SHALL SELECTIVELY REMOVE EXISTING ASPHALT PAVING AT EXISTING PARKING LOT DOWN TOGRAVEL BASE (V.I.F)-MAINTAIN EXISTING CONCRETE CURBS.-PATCH AND REPAIR EXISTING MATERIALS DAMAGED DURING CONSTRUCTION TO MATCH EXISTING MATERIALS.

Pawleys Island / Charleston

S RAG IC H T E C UT R E

COASTALCAROLINA

UNIVERSITYCHILD

DEVELOPMENT& LITERACY

CENTERRENOVATION

Notes:

Revisions:

106 CHANTICLEER DR. EASTCONWAY, SC 29526

Owner:

COASTAL CAROLINA UNIVERSITY# H17-N104-CB

Individual Seal

Corporate Seal

of

COPYRIGHT 2018 ALL RIGHTS RESERVEDPRINTED OR ELECTRONIC DRAWINGS ANDDOCUMENTATION MAY NOT BE REPRODUCEDIN ANY FORM WITHOUT WRITTENPERMISSION FROM SGA ARCHITECTURE

MEMBERS OFTHE AMERICAN INSTITUTE OF ARCHITECTS

Job Number: 17002Date: 02/08/2018Drawn by: HK, GHChecked by: SG

8263 Ocean Hwy.PO Box 1859Pawleys Island, SC 29585Phone: (843) 237-3421Fax: (843) 237-1992www.SGAarchitecture.com

5

5

4321

4321

A

B

C

D

E

F

Architect:

BID SET

2/8/

2018

9:2

6:17

AM

ASD101BID SET

DEMO SITE PLAN

1" = 20'-0"1 SITE PLAN DEMO

N

GENERAL NOTE:1. PROVIDE CONSTRUCTION FENCING AROUND DEMOLITION AREA, COORD. WITH OWNER.

2. MAINTAIN FIRE LANES/ACCESS THROUGHOUT CONSTRUCTION PROJECT.

3. SEE SHEET AS101 FOR FURTHER SITE INFORMATION.

REV. # Description Date

Page 5: CCU CHILD DEVELOPMENT AND...architectural site plan architectural a002 a003 d101 a101 a101a a102 a121 a352 a401 a701 a702 site details partition types demolition first plan first floor

2'-10"

F.E (N)

+/- 140' - 7 1/2"

+/- 5

1' -

5"

+/- 5

4' -

7"

+/- 21' - 2 1/2"

EXISTING

ACC

ESS RO

AD

+/- 8

9' -

11"

+/- 6

2' -

10 1

/2"

EXISTING ACCESS ROAD

EXIS

TIN

GAC

CES

S R

OAD

PLAYGROUND

37' -

4 1

/2"

130'

- 1"

66' - 2 1/2"

+/- 229' - 6"

57' - 2 1/2"

52' - 5"10' - 0 1/2"

20' -

0"

90' -

11"

V.I.F

+/- 2

9' -

2"

V.I.F

.

+/- 1

7' -

0"10

' - 0

"

5' -

0"

NEW SIDEWALKVERIFY GRADESLOPE, COORD.WITH CURRENT ADA

5' WIDE. BROOM FINISH ON MIN. 4" COMPACTED GRAVEL FILL.MATCH EXISTING WALK AT END (CONTROL POINTS @ 5' O.C)

PLAYGROUNDEQUIP, N.I.C.

7' -

6"7'

- 6"

7' - 6" 7' - 6" 7' - 6" 7' - 6"

TRASH RECEPTACLE,OFOI

TRASH RECEPTACLE,OFOI

BENCHOFOI

BENCH OFOI

FENCE

PROVIDE YELLOW PAINTSTRIPE FOR DROP OFF AREA

EXISTING ADA RAMP

PROVIDEONE-WAY

DO NOT ENTERSIGNAGE

PER OWNERREQ'DS

ONE-WAYDO NOT ENTER

SIGNAGEPER OWNER

REQ'DS----9

A351

TYP.----3

AS101TYP.

----

----

1A002

PROVIDE DIRECTIONALARROWS PER CCU REQ'D(S)

SEE SPECPROVIDE NEW ANGLED PARKING STRIPING

SEE SPEC

NEW ANGLED PARKING STRIPING

60.00°

60.00°

PROVIDE DIRECTIONALARROWS PER CCU REQ'D(S) (TYP.)

EXISTHC

EXISTHC

EXISTHC

EXISTHC

V.I.F.

142' - 0 1/2"

CH

ANTI

CLE

ER D

R.

3

A002

----4

AS101

GATE

BOLLARDSSEE 3/AS101

BOLLARDS

----2

A002

NEW GRAVITY VENTS (9)-COORD. LOCATIONWITH ARCHITECT, TYP.

REFER TODETAIL 4/ AS101

EDGE OFEXISTINGPAVEMENT

13' - 3" 6' - 8"

20' -

9 1

/2"

8' -

8"

FACE OF EXISTINGCONCRETE CURB

7' -

11 1

/2"

EXISTINGADA RAMPR 14' - 10 3/4"

EXISTING STRIPINGTO REMAIN

EXISTINGRAILING TOREMAIN

(E) TRANS.

(E). HVAC

1' - 4"

EDGE OFEXISTINGPAVEMENT

EXISTINGCONCRETEWALK

3' - 5 1/2"

BOLLARD-FILL W/ CONCRETE3000 PSI @ 28 DAYS

CROWN AT TOP TO PROVIDEPOSITIVE DRAINAGE - PAINT

ROUND SCHEDULE 40 STEELBOLLARD -PAINT.6" DIA.-SEE PLANS FOR LOCATION

3' -

0"4'

- 0"

0' -

0 1/

2"

0' - 6" 0' - 6" 0' - 6"

EXISTING PAVEMENT-PATCH AND REPAIR ASNECESSARY

CONCRETE FOOTING3000 PSI @ 28 DAYS

1' - 6"

MAI

NTA

IN T

HIC

KNES

S3"

TO

6"

FILL TO 12 INCHES (TO ALLOWFOR 25%COMPRESSION)

MU

LCH

WO

OD

EXIS

TIN

G B

ASE

TO R

EMAI

N

CO

MPA

CTE

D S

OIL

GEOTEXTILE FABRIC (N)

Pawleys Island / Charleston

S RAG IC H T E C UT R E

COASTALCAROLINA

UNIVERSITYCHILD

DEVELOPMENT& LITERACY

CENTERRENOVATION

Notes:

Revisions:

106 CHANTICLEER DR. EASTCONWAY, SC 29526

Owner:

COASTAL CAROLINA UNIVERSITY# H17-N104-CB

Individual Seal

Corporate Seal

of

COPYRIGHT 2018 ALL RIGHTS RESERVEDPRINTED OR ELECTRONIC DRAWINGS ANDDOCUMENTATION MAY NOT BE REPRODUCEDIN ANY FORM WITHOUT WRITTENPERMISSION FROM SGA ARCHITECTURE

MEMBERS OFTHE AMERICAN INSTITUTE OF ARCHITECTS

Job Number: 17002Date: 02/08/2018Drawn by: HK, GHChecked by: SG

8263 Ocean Hwy.PO Box 1859Pawleys Island, SC 29585Phone: (843) 237-3421Fax: (843) 237-1992www.SGAarchitecture.com

5

5

4321

4321

A

B

C

D

E

F

Architect:

BID SET

2/8/

2018

9:2

6:16

AM

AS101BID SET

ARCHITECTURALSITE PLAN

1" = 20'-0"1 SITE PLAN RENOVATION

N

2PROPOSED PLAYGROUNDPERSPECTIVE

NOTES:

1. PROVIDE SITE PREP, CEDAR MULCH (NON-CCA) OR WOOD CHIPS AT PLAYGROUNDOVER GEOTEXTILE CLOTH OVER 3-6 INCHES OF EXISTING GRAVEL BASE.-MULCH TO COMPLY WITH ASTM F1292-COMPLY WITH ADA GUIDELINES FOR STABILITY BASED ON ASTM F1951(NOTE: LOOSE FILL WILL COMPRESS OVER TIME, INITIAL FILL SHOULD REFLECTTHE 25% COMPRESSION PERCENTAGE).

*(IF HIGH TRAFFIC AREAS LIKE SWINGS OR SLIDES ARE INSTALLED, IMPACT ATTENUATING MATS SHOULD BE EMBEDDED UNDER LOOSE-FILL LAYER OF MULCH.)

2. TRASH RECEPTACLES AT PLAYGROUDN, OFOI

3. PROVIDE (2) BENCHES AT PLAYGROUND AREA.-ANCHOR BENCH TO GROUND PER MANUF. REQ'DS OFOI

4. PROVIDE (8) BOLLARDS MIN. AROUND PLAYGROUND-SEE DETAIL, THIS SHEET 3/AS101

5. PROVIDE ALUMINUM FENCE AND GATES. SEE DETAILS THIS SHEET AND A002 &SPECIFICATIONS 323119

PLAYGROUND EQUIP, N.I.C.

1" = 1'-0"3 BOLLARD

1" = 1'-0"4 PLAYGROUND FILL DETAILREV. # Description Date

Page 6: CCU CHILD DEVELOPMENT AND...architectural site plan architectural a002 a003 d101 a101 a101a a102 a121 a352 a401 a701 a702 site details partition types demolition first plan first floor

1:12 SLOPE

1:10 MAX1:10 MAX

4'-0"

SLOPE

MAX 1:12

SLOPE

MAX 1:12 MAX 1:12

SLOPE

6'-0" (TYP)

TAPER CURB AT RAMPELEVATION

SAWCUT 1/8" GROOVES @ " O.C.

TURNDOWN WALK OR CURB AND GUTTER(SEE LAYOUT PLANS FOR CURB TYPE)

95% COMPACTED SUBGRADE

SECTION

4" CONCRETE SLAB

ADJACENT PAVEMENT

SAWCUT 1/8" GROOVES @ 2" O.C.

TAPERED SIDE CURB CUTTYPE 1

CURB MAY BE STRAIGHT ORWITH RADIUS, SEE PLAN

1 3/4" FORERUNNER RAIL

1" SQ. PICKET

3 3/4" TYP.

2" SQ. GATE END

3" SQ. POST

LATCH AND ROD-COORD LOCKING WITH OWNER

6' -

0"

4' - 2 1/2"

SEE FOOTING NOTES3/A002

3" SQ. POST

1 3/4" FORERUNNER RAIL

EXISTING PAVEMENT-PATCH AND REPAIR ASNECESSARY

CONCRETE FOOTING3000 PSI @ 28 DAYS-PER MANUF. REQ'DS

1' - 6"

1" SQ. PICKET

3 3/4" TYP.

4' -

6"0'

- 9"

6' -

0"

ELEVATION

0' -

6"2'

- 6"

3' -

0"

Pawleys Island / Charleston

S RAG IC H T E C UT R E

COASTALCAROLINA

UNIVERSITYCHILD

DEVELOPMENT& LITERACY

CENTERRENOVATION

Notes:

Revisions:

106 CHANTICLEER DR. EASTCONWAY, SC 29526

Owner:

COASTAL CAROLINA UNIVERSITY# H17-N104-CB

Individual Seal

Corporate Seal

of

COPYRIGHT 2018 ALL RIGHTS RESERVEDPRINTED OR ELECTRONIC DRAWINGS ANDDOCUMENTATION MAY NOT BE REPRODUCEDIN ANY FORM WITHOUT WRITTENPERMISSION FROM SGA ARCHITECTURE

MEMBERS OFTHE AMERICAN INSTITUTE OF ARCHITECTS

Job Number: 17002Date: 02/08/2018Drawn by: HK, GHChecked by: SG

8263 Ocean Hwy.PO Box 1859Pawleys Island, SC 29585Phone: (843) 237-3421Fax: (843) 237-1992www.SGAarchitecture.com

5

5

4321

4321

A

B

C

D

E

F

Architect:

BID SET

2/8/

2018

9:2

5:53

AM

A002BID SET

SITE DETAILS

1" = 1'-0"1 FENCE GATE

1/2" = 1'-0"2 ADA RAMP

1" = 1'-0"3 Fence detail

REV. # Description Date

Page 7: CCU CHILD DEVELOPMENT AND...architectural site plan architectural a002 a003 d101 a101 a101a a102 a121 a352 a401 a701 a702 site details partition types demolition first plan first floor

M1

EXISTING 8" CMU

EXISTING FURRINGV.I.F.AT TYPE M2 ONLYAT TYPE M1 (NO FURRING)

ACOUSTIC INSULATION

FLOOR SYSTEM AS SCHEDULED

2X6" WOOD STUDS AT 16" O.C.AT PLUMBING WALL2X4" WOOD STUDS AT 16" O.C.OTHWERWISE

TILE ONE SIDE,REFER TO FINISH SCHEDULE

BASE AS SCHEDULED

5/8" MOISTURE RESISTANTBACKER BOARD OR 5/8"GYPSUM WALL BOARD TYPE "X"WHERE RATED.MOISTURE RESISTANT

ACOUSTIC INSULATION

FLOOR SYSTEM AS SCHEDULED

2X4" WOOD STUDS 16" O.C.

5/8" GYPSUM WALL BOARDUSE 5/8" TYPE 'X' GYPSUM WALL BOARDAT CORRIDORS (BOTH SIDES)REFER TO ROOM FINISH SCHEDULE

J-BEAD AND FIRE STOP SEALANT

W68

EXISTING 1-HOUR FIRE RATED -SEE G SHEETS FOR CODE INFO

W64

ROOM SIDE CORRIDOR SIDE

M2M3

EXISTING 8" CMU

EXISTING 1-HOUR FIRE RATED -SEE G SHEETS FOR CODE INFO

ROOM SIDE CORRIDOR SIDE

EXISTING GYP. BD.OVER EXISTING FURRING

(2) LAYERS OF 5/8" GYP BD.AT CORRIDOR SIDE ONLYAT PARTITION TYPE W68

ACOUSTIC CEILING TILE

W68A

PROVIDE FIRE BLOCKINGAT CORRIDOR WALL TYPE W68

(1) 5/8" TYPE 'X' GYP. BD.OVER 1 1/2" WOOD STUDFURRING AT TYPE M3-WALL MAY NEED TO BE FURRED OUTTO ACCOMODATE PLUMBING- SEE PLUMBING DWGS.

W64AW64R

5/8" GYP. B.D.ONLY AT TYPE W64

5/8" GYP. BD. TYPE 'X'AT TYPE W64R

J-BEAD AND FIRE STOP SEALANTAT TYPE W64R

GYP CEILINGAT RESTROOMS

MAINTAIN AND REPLACE IF MISSINGJ-BEAD AND FIRE STOP SEALANT

EXISTING GYP BD. CEILING-REPAIR/REPLACE IF MISSING ORDAMAGED

MAINTAIN AND REPLACE IF MISSINGJ-BEAD AND FIRE STOP SEALANT

EXISTING GYP BD. CEILING-REPAIR/REPLACE IF MISSING ORDAMAGED

BASE AS SCHEDULED BASE AS SCHEDULED BASE AS SCHEDULED

T/EX. SLABEL. 43.25'

T/EX. SLABEL. 40.58'

FIEL

D V

ERIF

Y EX

IST

CO

ND

.

NOTE:-PATCH AND REPAIR MASONRY AND CONCRETE,MATCH EXISTING COLORS AND TEXTURES.-REPAIR ADJACENT MATERIAL DAMAGED DURINGCONSTRUCTION.-REPLACE ANY REMOVED OR DAMAGEDLANDSCAPING, SOIL, DRAIN PIPE, ETC., THATOCCURED DURING CONSTRUCTION

SEE PLUMBING DRAWINGSFOR DEMOLITION NOTESON PLUMBING VENT ANDDOMESTIC WATER SERVICE

GENERAL NOTES:

1. NTERIOR DIMENSIONS ARE TAKEN FROM FINISH FACE UNLESS NOTED OTHERWISE.

2. ALL DIMENSIONS NOTED "CLEAR" ARE TO FACE OF FINISHED WALL SURFACE UNLESS NOTED OTHERWISE.

3. DOORS AND WINDOWS ARE DIMENSIONED TO CENTERS, WALL OPENINGS ARE DIMENSIONED TO FACE OF STUD UNLESSOTHERWISE NOTED.

4. BRING ANY DISCREPANCIES TO THE ATTENTION OF THE DESIGNER BEFORE BEGINNING WORK.

5. THE CONTRACTOR SHOULD CONFIRM AND CONFORM WITH ALL BUILDING CODE AND ZONING REQUIREMENTS WITH RESPECT TO THESE PLANS. ALL BUILDING CODE AND ZONING REQUIREMENTS TO BE CONFIRMED BEFORESTARTING ANY WORK.

6. THE CONTRACTOR SHOULD VERIFY ALL HANDRAIL CONFIGURATIONS AND COMPLIANCE WITH CODE.

7. THE CONTRACTOR SHALL VERIFY ALL EXISTING FIELD CONDITIONS AND COORDINATE WITH THE ARCHITECT.

8. COORDINATE ALL MECHANICAL, ELECTRICAL AND PLUMBING WITH CONSULTANT DRAWINGS.

9. SEE PARTITION SCHEDULE A003 FOR PARTITION TYPES. ALL PARTITIONS ARE W68 UNLESS NOTED OTHERWISE.

10. SHALL SALVAGE HOLLOW METAL DOOR AND FRAME, AND PROVIDE CMU INFILL TO MATCH EXISTING AS MUCH AS POSSIBLE.

11. SEE PARTITION TYPES FOR FOR WALL CONSTRUCITON, SOME EXISTING CMU WALLS HAVE GYP BD. FURRING.

12. CUBBIES & WALL MOUNTED COAT HOOKS - FURNITURE OFOI

13. REF - REFRIDGERATOR OFOI

14. PROVIDE THROUGH PENETRATION FIRE STOP SYSTEMS AT ALL RATED PARTITIONS & CEILINGS

FIRST FLOOR10' - 0"

SECOND FLOOR21' - 10 1/4"

8 9 10 11 12

PROPOSED1 HR CEILINGAT CORRIDORS

CHILDDEVELOPMENT

109CORRIDOR

C02HALLC03

CHILDDEVELOPMENT

111

EXISTING ROOF & FRAMING TO REMAIN

EXISTINGFRAMING TOREMAIN

FIEL

D V

ERIF

Y EX

IST

CO

ND

.

NOTE:-PATCH AND REPAIR MASONRY AND CONCRETE,MATCH EXISTING COLORS AND TEXTURES.-NEW BRICK VENEER SHALL BE COLOR SELECTEDBY ARCHITECT-REPAIR ADJACENT MATERIAL DAMAGED DURINGCONSTRUCTION.-REPLACE ANY REMOVED OR DAMAGEDLANDSCAPING, SOIL, DRAIN PIPE, ETC., THATOCCURED DURING CONSTRUCTION

BRICK VENEEROVER 2 INCH RIGID INSULOVER 8 INCH CMU-COLOR SELECTION PER ARCHITECT

3' -

0"

HM WINDOW SYSTEM-SEE SCHED.

SEALANT AND BACKER ROD

0' - 3"

EXISTING CONC SLABEXISTING CONC WALKWAY

DEMO CONC THRESHOLDBACK TO EXISTING CMU WALLPREP EXISTING CMU FORNEW CMU INFILL - V.I.F. EXISTINGWALL CONDITIONS PRIORTO CONSTRUCTION

PROVIDE MASONRYTIES AT 16" O.C. -VERT.

EXIST. FOOTING

EXISTING LINTEL TO REMAIN

PAN FLASHING

GROUT FILL SOLID

Pawleys Island / Charleston

S RAG IC H T E C UT R E

COASTALCAROLINA

UNIVERSITYCHILD

DEVELOPMENT& LITERACY

CENTERRENOVATION

Notes:

Revisions:

106 CHANTICLEER DR. EASTCONWAY, SC 29526

Owner:

COASTAL CAROLINA UNIVERSITY# H17-N104-CB

Individual Seal

Corporate Seal

of

COPYRIGHT 2018 ALL RIGHTS RESERVEDPRINTED OR ELECTRONIC DRAWINGS ANDDOCUMENTATION MAY NOT BE REPRODUCEDIN ANY FORM WITHOUT WRITTENPERMISSION FROM SGA ARCHITECTURE

MEMBERS OFTHE AMERICAN INSTITUTE OF ARCHITECTS

Job Number: 17002Date: 02/08/2018Drawn by: HK, GHChecked by: SG

8263 Ocean Hwy.PO Box 1859Pawleys Island, SC 29585Phone: (843) 237-3421Fax: (843) 237-1992www.SGAarchitecture.com

5

5

4321

4321

A

B

C

D

E

F

Architect:

BID SET

2/8/

2018

9:4

3:24

AM

A003BID SET

PARTITIONTYPES & TYPICAL

HEIGHTS

1 1/2" = 1'-0"1 PARTITION TYPES

1 1/2" = 1'-0"2 EXISTING FOUNDATION

3/16" = 1'-0"3 EXISTING BUILDING SECTION 1 1/2" = 1'-0"4 INFILL AT MASONRY OPENING

REV. # Description Date

Page 8: CCU CHILD DEVELOPMENT AND...architectural site plan architectural a002 a003 d101 a101 a101a a102 a121 a352 a401 a701 a702 site details partition types demolition first plan first floor

UP

UP

1 2 3 4 5 6 7

8

9

10

11

12

3

4

4

5

PRESERVE DATAPER ELEC. DWGS.RELOCATE TO MAINCORRIDOR

PRESERVE DATAPER ELEC. DWGS.RELOCATE TO MAINCORRIDOR

CUT EXISTING SLABFOR PLUMIBNG TRENCH-PROTECT AND MAINTAIN EXISTINGSHEET FLOORING AROUND TRENCHAT CORRIDOR-PATCH AND REPAIR EXISTING MATERIALAND FINISHES DAMAGED BY CONSTRUCTION-EXISTING SHEET FLOORING AT CORRIDORTO REMAIN

CUT EXISTING SLABFOR PLUMIBNG TRENCH-PROTECT AND MAINTAIN EXISTINGCONCRETE SLAB AROUND TRENCH-PATCH AND REPAIR EXISTING MATERIAL DAMAGED BY CONSTRUCTION

TRENCH

TRENCH

EXISTING PLUMBING WASTE & VENT ANDDOMESTIC WATERTO BE RELOCATED, SEE PLUMBING DRAWINGS.-SEE SHEET A003 FOR WALL CONSTRUCTION DETAIL

7

7

7

1

1

1

1

1

1

TRENCH

7

4

REMOVE EXISTING P.L.SHELF - PATCH CMU

FIRST AID CABINETREMOVED BYOWNER

KEY NOTES:

1. REMOVE DOOR AND FRAME FOR RELOCATION

3. SHALL REMOVE DOOR, MAINTAIN FRAME IN OPENING

4. SHALL REMOVE DOOR AND FRAME AND PREP OPENING FOR WALL PATCH, SEE SHEET A101 FOR FURTHER INFORMATION

5. SHALL REMOVE OVERHEAD DOOR AND FRAME AND ANY ASSOCIATED MOTOR OR CHAIN.

7. CONTRACTOR SHALL SAW CUT CONCRETE SLAB AND WALLS AS REQUIRED FOR PROPOSED PLUMBING PIPING.

GENERAL DEMO NOTES:

1. SELECTIVELY DEMOLISH WALLS AND CASEWORK SHOWN DASHED, UNLESS OTHERWISE NOTED.

2. SALVAGE ALL DOORS AND FRAMES, STORE IN PROTECTIVE LOCATION FOR RE-USE BY CONTRACTOR FOR THIS PROJECT.

2. PATCH AND REPAIR WALLS, FLOOR AND CEILINGS DUE TO REMOVAL AS NECESSARY, MATCH ADJACENT MATERIALS AND FINISHAS NEEDED.

4. BRING ANY DISCREPANCIES TO THE ATTENTION OF THE DESIGNER BEFORE BEGINNING WORK.

5. THE CONTRACTOR SHOULD CONFIRM AND CONFORM WITH ALL BUILDING CODE AND ZONING REQUIREMENTS WITH RESPECT TOTHESE PLANS. ALL BUILDING CODE AND ZONING REQUIREMENTS TO BE CONFIRMED BEFORE STARTING ANY WORK.

6. THE CONTRACTOR SHOULD VERIFY ALL HANDRAIL CONFIGURATIONS AND COMPLIANCE WITH CODE.

7. THE CONTRACTOR SHALL VERIFY ALL EXISTING FIELD CONDITIONS AND COORDINATE WITH THE ARCHITECT.

8. SEE PLUMBING DRAWINGS FOR TRENCHING/ NEW PLUMBING LINE LOCATIONS.

9. COORDINATE ALL MECHANICAL, ELECTRICAL AND PLUMBING WITH CONSULTANT DRAWINGS.

10. REFER TO ROOM FINISH SCHEDULE FOR FLOORS & CEILINGS

11. EXISTING INTERIOR SIGNAGE TO BE REMOVED AND SALVAGED - DELIVER TO OWNER.

Pawleys Island / Charleston

S RAG IC H T E C UT R E

COASTALCAROLINA

UNIVERSITYCHILD

DEVELOPMENT& LITERACY

CENTERRENOVATION

Notes:

Revisions:

106 CHANTICLEER DR. EASTCONWAY, SC 29526

Owner:

COASTAL CAROLINA UNIVERSITY# H17-N104-CB

Individual Seal

Corporate Seal

of

COPYRIGHT 2018 ALL RIGHTS RESERVEDPRINTED OR ELECTRONIC DRAWINGS ANDDOCUMENTATION MAY NOT BE REPRODUCEDIN ANY FORM WITHOUT WRITTENPERMISSION FROM SGA ARCHITECTURE

MEMBERS OFTHE AMERICAN INSTITUTE OF ARCHITECTS

Job Number: 17002Date: 02/08/2018Drawn by: HK, GHChecked by: SG

8263 Ocean Hwy.PO Box 1859Pawleys Island, SC 29585Phone: (843) 237-3421Fax: (843) 237-1992www.SGAarchitecture.com

5

5

4321

4321

A

B

C

D

E

F

Architect:

BID SET

2/8/

2018

9:2

6:18

AM

D101BID SET

DEMO FLOORPLAN

3/16" = 1'-0"1 FIRST FLOOR DEMO

N

REV. # Description Date

Page 9: CCU CHILD DEVELOPMENT AND...architectural site plan architectural a002 a003 d101 a101 a101a a102 a121 a352 a401 a701 a702 site details partition types demolition first plan first floor

UP

UP

REF

.

REF.

REF

.REF.

REF

.

FAAPF.E (E)

F.E

(E)

F.E (E)

F.E (N)

F.E

(N)

F.E (N)

A4011

CHILDDEVELOPMENT

109

LITERACY116

LITERACY117

CUSTODIAL118

BREAK ROOM103D

OFFICE103C

DIRECTOR103A

CHILDDEVELOPMENT

101

RESTROOM102

CHILDDEVELOPMENT

104

RESTROOM105

EX.IT/ELECTRICAL

108

EX. WOMENS107

EX. MENS106

CORRIDORC01

EX. STAIRS02

LITERACY119

LITERACY120

EX. MECHANICAL121

EX. CALL CENTER122

EX. TOILET123

HALLC06

EX. STAIRS01

CORRIDORC02

HALLC05

OFFICE103B

LITERACY115

CHILDDEVELOPMENT

111

HALLC03

OFFICE114

RESTROOM112

HALLC04

RESTROOM110

HALL103

ALCOVE104A

CLEAR4' - 0"

CLE

AR

5' -

0"

CLE

AR5'

- 0"

CLEAR5' - 0"

CUBBIES

CUBBIES

CUBBIES

CUBBIES

REF

REF

REF

REF

REF

3-5 years

3-5 years

3-5 years

3-5 years

COPIERNIC

STAFFSTORAGENIC

A7015

111

A

8 111 E

6 111 B

7

111

C

1 2 3 4 5 6 7

8

9

10

11

12

CLEAR (EXIST) V.I.F.

10' - 0"

V.I.F.

+/- 47'-4"

V.I.F

.

25' -

11"

±

CLE

AR

4' -

8"

1' -

7"11

' - 0

1/2

"6'

- 6"

8' - 0" 1' - 2 1/2"

2' -

4 1/

2"1'

- 0

1/2"

7' -

6"5'

- 0"

2' -

11 1

/2"

4' -

8"1'

- 11

"5'

- 7

1/2"

9' - 8 1/2" 11' - 1 1/2"

CLEAR

19' - 10"

14' - 8" 2' - 2" 6' - 3"0' - 8 1/2"

12' - 2"

11' - 11 1/2" 2' - 3 1/2"

CLEAR

20' - 4"

CLEAR

9' - 4"

116 117

119 120

108B

121

C06

S01109A

S02

106

107

108

C01

C02B

C02A

103E

115A

115B

103A 103C

C03

111B

112

102

110

105

114

122

103BA701

9 101 A

11101 C

12

101

D

10

101

B

A701 1

109

A4 109 D

3

109

C

2 109 BA70113

104

A 14104 B

15

104

C

16104 D

1' - 10 1/2" 8' - 0"

5' -

8"2'

- 2"

5' -

2 1/

2"3'

- 0

1/2"

1' -

11 1

/2"

11' -

5 1

/2"

0' -

4"

A702

1 CO1 3 - a

2 C01 3 - c

A3513

6' -

8"

A7025

103D

A

A7023

C02

1 -

a

4

C02

1 -

c

NEWDRINKINGFOUNTAIN& BOTTLE FILLINGSTATION

EXISTING DRINKINGFOUNTAIN

W64W68A

M1M

M1M2

W68W64R

W64W68W64

W64

W64

W68W64W68W64

W64A

W68W64

W64

W64

20' - 2 1/2" 14' - 8" 12' - 6" 10' - 0" 47' - 4"

V.I.F.

+/- 26' - 0"V.I.F.

+/- 130' - 8"

4' -

4 1/

2"10

' - 1

"30

' - 3

1/2

"

V.I.F

.

+/- 7

0' -

8"

CLOSETC07

CLOSET108A

C07

103D

101

104

111A

103

COORD. EXISTINGWALL FOR DATA

A3511

V.I.F

7' - 2"

6' -

7 1/

2"

11' - 7" 2' - 2" 5' - 9 1/2"

1' -

9 1/

2"

2' - 3 1/2"

3' -

3 1/

2"

A701 17

111

D

----2

A003

2

M1

M1 M1

W68

M1

M1

M1

M1M1

M2

N.I.C

W68A

M1

N.I.C.

EXISTINGOBSERVATIONWINDOW

EXISTINGOBSERVATIONWINDOW

M3

108A

31 31

24

24

24

A702

9 C05 A

A351

8 106 A

EXISTINGADA ACCESSIBLE ENTRANCE

ACCESS CONTROLFAMILY ENTRY

W68W68A W68W68A

W68W68A

2

2

W68

W68

W681

W68W68A

FAAP PANEL (N)RMS PANEL (N)REFER TO ELECTRICAL DRAWINGS

N.I.C.

N.I.C.

118

3A003

V.I.F.3' - 0"

V.I.F

.1'

- 7"

M1

M1

PROVIDE CONCRETEHOUSEKEEPING PAD FORHWH - V.I.F

109B

EXISTING DOOR TO REMAIN

123

EXISTING DOOR TO REMAIN

32

W68

W68

W68

W68

W68

W64R

W68

W68

W68

W68

W68

W68

W68W68

W68

M1 M1W68

EXISTINGWINDOW UNITSTO REMAIN (TYP.)U.N.O

3' -

4"2'

- 6"

2' -

6"

C05

4

A003

Sim

8' -

4" ±

U.N.O

U.N.O

M2 M1

W64

1

EXISTING DISPLAYCABINET TO REMAIN

0' - 3"

KEY NOTES:

1. V.I.F. EXISTING COLUMNS AND COORDINATE WITH NEW WALL PARTITIONS. IF ANY CONFLICTS DISCOVERED, NOTIFY ARCHTIECT BEFORE PROCEEDING.

2. OFOI, NEW DOOR AND FRAME. COORD. DOOR HARDWARE, ACCESS CONTROL WITH DOOR INSTALLATION., COORD. WITH OWNER.

GENERAL NOTES:

1. NTERIOR DIMENSIONS ARE TAKEN FROM FINISH FACE UNLESS NOTED OTHERWISE.

2. ALL DIMENSIONS NOTED "CLEAR" ARE TO FACE OF FINISHED WALL SURFACE UNLESS NOTED OTHERWISE.

3. DOORS AND WINDOWS ARE DIMENSIONED TO CENTERS, WALL OPENINGS ARE DIMENSIONED TO FACE OF STUD UNLESSOTHERWISE NOTED.

4. BRING ANY DISCREPANCIES TO THE ATTENTION OF THE DESIGNER BEFORE BEGINNING WORK.

5. THE CONTRACTOR SHOULD CONFIRM AND CONFORM WITH ALL BUILDING CODE AND ZONING REQUIREMENTS WITH RESPECT TO THESE PLANS. ALL BUILDING CODE AND ZONING REQUIREMENTS TO BE CONFIRMED BEFORESTARTING ANY WORK.

6. THE CONTRACTOR SHOULD VERIFY ALL HANDRAIL CONFIGURATIONS AND COMPLIANCE WITH CODE.

7. THE CONTRACTOR SHALL VERIFY ALL EXISTING FIELD CONDITIONS AND COORDINATE WITH THE ARCHITECT.

8. COORDINATE ALL MECHANICAL, ELECTRICAL AND PLUMBING WITH CONSULTANT DRAWINGS.

9. SEE PARTITION SCHEDULE A003 FOR PARTITION TYPES. ALL PARTITIONS ARE W68 UNLESS NOTED OTHERWISE.

10. SHALL SALVAGE HOLLOW METAL DOOR AND FRAME, AND PROVIDE CMU INFILL TO MATCH EXISTING AS MUCH AS POSSIBLE.

11. SEE PARTITION TYPES FOR FOR WALL CONSTRUCITON, SOME EXISTING CMU WALLS HAVE GYP BD. FURRING.

12. CUBBIES & WALL MOUNTED COAT HOOKS - FURNITURE OFOI

13. REF - REFRIDGERATOR OFOI

14. PROVIDE THROUGH PENETRATION FIRE STOP SYSTEMS AT ALL RATED PARTITIONS & CEILINGS

EXISTING TO REMAIN U.N.O

NEW CONSTRUCTION

EXISTING TO REMAIN

1 HOUR RATE PARTITION

Pawleys Island / Charleston

S RAG IC H T E C UT R E

COASTALCAROLINA

UNIVERSITYCHILD

DEVELOPMENT& LITERACY

CENTERRENOVATION

Notes:

Revisions:

106 CHANTICLEER DR. EASTCONWAY, SC 29526

Owner:

COASTAL CAROLINA UNIVERSITY# H17-N104-CB

Individual Seal

Corporate Seal

of

COPYRIGHT 2018 ALL RIGHTS RESERVEDPRINTED OR ELECTRONIC DRAWINGS ANDDOCUMENTATION MAY NOT BE REPRODUCEDIN ANY FORM WITHOUT WRITTENPERMISSION FROM SGA ARCHITECTURE

MEMBERS OFTHE AMERICAN INSTITUTE OF ARCHITECTS

Job Number: 17002Date: 02/08/2018Drawn by: HK, GHChecked by: SG

8263 Ocean Hwy.PO Box 1859Pawleys Island, SC 29585Phone: (843) 237-3421Fax: (843) 237-1992www.SGAarchitecture.com

5

5

4321

4321

A

B

C

D

E

F

Architect:

BID SET

2/8/

2018

9:4

1:55

AM

A101BID SET

FIRST FLOORPLAN

3/16" = 1'-0"1 FIRST FLOOR RENOVATION

NOTE:ALL DIMENSIONS ARE NOTGUARENTEED AND ARESUBJECT TO CHANGE

N

REV. # Description Date

Page 10: CCU CHILD DEVELOPMENT AND...architectural site plan architectural a002 a003 d101 a101 a101a a102 a121 a352 a401 a701 a702 site details partition types demolition first plan first floor

F.E (E)

F.E

(E)

F.E (E)

F.E (N)

F.E

(N)

F.E (N)

CHILDDEVELOPMENT

109

LITERACY116

LITERACY117

CUSTODIAL118

BREAK ROOM103D

OFFICE103C

DIRECTOR103A

CHILDDEVELOPMENT

101

RESTROOM102

CHILDDEVELOPMENT

104 RESTROOM105

EX.IT/ELECTRICAL

108

EX. WOMENS107

EX. MENS106

CORRIDORC01

EX. STAIRS02

LITERACY119

LITERACY120

EX. MECHANICAL121

EX. CALL CENTER122

EX. TOILET123

HALLC06

EX. STAIRS01

CORRIDORC02

HALLC05

OFFICE103B

LITERACY115

CHILDDEVELOPMENT

111

HALLC03

OFFICE114

RESTROOM112

HALLC04

RESTROOM110

HALL103

ALCOVE104A

CLOSETC07

CLOSET108A

N.I.C.

N.I.C.

EXISTING FLOORING TO REMAIN

BBT-1

BBT-2

BBT-3

PFT-1

CPT-1

CPT-2

CPT-3

SC

Pawleys Island / Charleston

S RAG IC H T E C UT R E

COASTALCAROLINA

UNIVERSITYCHILD

DEVELOPMENT& LITERACY

CENTERRENOVATION

Notes:

Revisions:

106 CHANTICLEER DR. EASTCONWAY, SC 29526

Owner:

COASTAL CAROLINA UNIVERSITY# H17-N104-CB

Individual Seal

Corporate Seal

of

COPYRIGHT 2018 ALL RIGHTS RESERVEDPRINTED OR ELECTRONIC DRAWINGS ANDDOCUMENTATION MAY NOT BE REPRODUCEDIN ANY FORM WITHOUT WRITTENPERMISSION FROM SGA ARCHITECTURE

MEMBERS OFTHE AMERICAN INSTITUTE OF ARCHITECTS

Job Number: 17002Date: 02/08/2018Drawn by: HK, GHChecked by: SG

8263 Ocean Hwy.PO Box 1859Pawleys Island, SC 29585Phone: (843) 237-3421Fax: (843) 237-1992www.SGAarchitecture.com

5

5

4321

4321

A

B

C

D

E

F

Architect:

BID SET

2/8/

2018

9:2

6:02

AM

A101ABID SET

FLOOR FINISHPLAN

3/16" = 1'-0"1 FLOOR FINISH PLAN

REV. # Description Date

Page 11: CCU CHILD DEVELOPMENT AND...architectural site plan architectural a002 a003 d101 a101 a101a a102 a121 a352 a401 a701 a702 site details partition types demolition first plan first floor

1 2 3 4 5 6 7

8

9

10

11

12

EXISTINGAHU

EXISTINGAHU

EXISTINGAHU

EXISTINGAHU

EXISTINGSTAIR

EXISTINGSTAIR

----

3A003

Pawleys Island / Charleston

S RAG IC H T E C UT R E

COASTALCAROLINA

UNIVERSITYCHILD

DEVELOPMENT& LITERACY

CENTERRENOVATION

Notes:

Revisions:

106 CHANTICLEER DR. EASTCONWAY, SC 29526

Owner:

COASTAL CAROLINA UNIVERSITY# H17-N104-CB

Individual Seal

Corporate Seal

of

COPYRIGHT 2018 ALL RIGHTS RESERVEDPRINTED OR ELECTRONIC DRAWINGS ANDDOCUMENTATION MAY NOT BE REPRODUCEDIN ANY FORM WITHOUT WRITTENPERMISSION FROM SGA ARCHITECTURE

MEMBERS OFTHE AMERICAN INSTITUTE OF ARCHITECTS

Job Number: 17002Date: 02/08/2018Drawn by: HK, GHChecked by: SG

8263 Ocean Hwy.PO Box 1859Pawleys Island, SC 29585Phone: (843) 237-3421Fax: (843) 237-1992www.SGAarchitecture.com

5

5

4321

4321

A

B

C

D

E

F

Architect:

BID SET

2/8/

2018

9:2

6:03

AM

A102BID SET

SECOND FLOORPLAN

3/16" = 1'-0"1 SECOND FLOOR

N

NOTE:NO ARCHITECTURE WORK AT THIS LEVEL-COORDINATE WITH MECH., & ELEC. DWGS.

REV. # Description Date

Page 12: CCU CHILD DEVELOPMENT AND...architectural site plan architectural a002 a003 d101 a101 a101a a102 a121 a352 a401 a701 a702 site details partition types demolition first plan first floor

1 2 3 4 5 6 7

8

9

10

11

12

EXISTING CEILINGAND LIGHTING TOREMAIN

EXISTING CEILINGAND LIGHTING TOREMAIN

EXISTING CEILING ANDLIGHTING TO REMAIN

N.I.C.

N.I.C.

PROVIDE RATEDGYP. BD. CEILINGABOVE

EXISTING CEILINGAND LIGHTING TOREMAIN

EXISTING CEILINGAND LIGHTING TOREMAIN

----

3A003

9'-2"

8'-6" 8'-6"

8'-6"

8'-6"

9'-2"

9'-2"

9'-2"

9'-2"

9'-2"

9'-2"

9'-0"

ETR

ETR

ETR

ETR

CHILDDEVELOPMENT

101

DIRECTOR103A

OFFICE103C

HALL103

RESTROOM102

OFFICE103B

BREAK ROOM103D

CORRIDORC02CORRIDOR

C01

CHILDDEVELOPMENT

111

EX. CALL CENTER122

HALLC06

EX. MECHANICAL121

EX. TOILET123

EX. STAIRS01

LITERACY115

CUSTODIAL118

CHILDDEVELOPMENT

109

RESTROOM110

OFFICE114

LITERACY116

LITERACY117

LITERACY119

LITERACY120

HALLC03

RESTROOM112

EX.IT/ELECTRICAL

108CLOSET

108AALCOVE

104A

CHILDDEVELOPMENT

104

RESTROOM105

EX. WOMENS107

EX. MENS106

1

1

1

1

1

1

PAINT EXISTNGSOFFIT

HALLC04

9'-0"

KEY NOTES:

1. EXISTING CEILING TO REMIAN, V.I.F. EXISTING CEILING HEIGTS ANDMAINTAIN EXISTING GYP BD. 1 HR CEILING ABOVE EXISTING CORRIDORS,REPAIR ANY DAMAGED GYP BD. CEILINGS AS NEEDED TO MAINTAIN 1 HRFIRE RATING.

SYMBOL RCP LEGEND

NEW 1X4 SURFACE MOUNT LED LIGHTFIXTURE

NEW 2X2' RECESSED LED LIGHT FIXTURE

NEW RECESSED LED CAN LIGHT FIXTURE

EXISTING 2X4 LIGHT FIXTURE

EXISTING 2X2 LIGHT FIXTURE

NEW DIFFUSER -SEE MECH & ELEC. DWGS

NEW RETURN

EXISTING DIFFUSER

EXISTING RETURN

SEISMIC CATEGORY D

-MINIMUM 2" WALL MOLDING-GRID MUST BE ATTACHED TO TWO ADJACENT WALLS;OPPOSITE WALLS MUST HAVE 3/4" CLEARANCE-ENDS OF MAIN BEAMS AND CROSS TEES MUST BE TIEDTOGETHER TO PREVENT THEIR SPREADING.-HEAVY-DUTY GRID SYSTEM.-CEILING AREAS OVER 1,000 SF MUST HAVE HORIZONTALRESTRAINT WIRE OR RIGID BRACING.-CEILING AREAS OVER 2,500 SF MUST HAVE SEISMIC SEPARATIONJOINTS OR FULL HEIGHT PARTITIONS.-CEILINGS WITHOUT RIGID BRACING MUST HAVE 2"OVERSIZED TRIM RINGS FOR SPRINKLERS AND OTHERPENETRATIONS.-CHANGES IN CEILING PLANE MUST HAVE POSITIVE BRACING-CABLE TRAYS AND ELECTRICAL CONDUITS MUST BEINDEPENDENTLY SUPPORTED AND BRACED.-PERIMETER SUPPORT WIRES WITHIN 8"

CEILING PANEL INSTALLATION @ LIGHT FIXTURE CEILING PANEL INSTALLATION @ DETAILCEILING PANEL INSTALLATION DETAIL

LIGHT FIXTURE FRAME

12-GAUGE WIRE ANCHOREDTO STRUCTURE ABOVE,MIN. 3 TIGHT TURNSIN 1 1/2" AT EACH ENDOF WIRETYPICAL AT CEILINGS OF1,000 SQ. FT. OR MORE

CROSS RUNNER

12 GAUGE WIRE ANCHOREDTO STRUCTURE ABOVE,MIN. 3 TIGHT TURNS IN1 1/2" AT EACH ENDOF WIRE

CEILING PANEL

ADJUSTABLE LENGTH VERTICALCOMPRESSION STRUT TO PREVENTVERTICAL MOVEMENTANCHOR TO STRUCTURE ABOVETYPICAL AT CEILINGS OF1,000 SQ. FT. OR MORE

MAIN RUNNER

PROVIDE 4-WAY DIAGONAL BRACING AND COMPRESSIONSTRUTS APPROXIMATELY EVERY 12 FT. EACH WAY

Pawleys Island / Charleston

S RAG IC H T E C UT R E

COASTALCAROLINA

UNIVERSITYCHILD

DEVELOPMENT& LITERACY

CENTERRENOVATION

Notes:

Revisions:

106 CHANTICLEER DR. EASTCONWAY, SC 29526

Owner:

COASTAL CAROLINA UNIVERSITY# H17-N104-CB

Individual Seal

Corporate Seal

of

COPYRIGHT 2018 ALL RIGHTS RESERVEDPRINTED OR ELECTRONIC DRAWINGS ANDDOCUMENTATION MAY NOT BE REPRODUCEDIN ANY FORM WITHOUT WRITTENPERMISSION FROM SGA ARCHITECTURE

MEMBERS OFTHE AMERICAN INSTITUTE OF ARCHITECTS

Job Number: 17002Date: 02/08/2018Drawn by: HK, GHChecked by: SG

8263 Ocean Hwy.PO Box 1859Pawleys Island, SC 29585Phone: (843) 237-3421Fax: (843) 237-1992www.SGAarchitecture.com

5

5

4321

4321

A

B

C

D

E

F

Architect:

BID SET

2/8/

2018

9:2

6:06

AM

A121BID SET

FIRST FLOORREFLECTED

CEILING PLAN

3/16" = 1'-0"1 FIRST FLOOR N

GENERAL NOTE:

1. SEE MECH. AND ELEC. DWGS.

2. SEE PARTITION TYPES ON SHEET A003 FOR WALL AND CEILING INFORMATION

1

11

1

REV. # Description Date

Page 13: CCU CHILD DEVELOPMENT AND...architectural site plan architectural a002 a003 d101 a101 a101a a102 a121 a352 a401 a701 a702 site details partition types demolition first plan first floor

SCHLUTER RENO-U

PORCELAIN TILE

CONCRETE

18" MIN

A702

10A-TYP RM

CHILD

12"-15"

A6

A2

13

1 - d

121 - c

11

1 - b

2' - 1"

A3

HEAD

JAMB

8" CMU BLOCK - REFERTO STRUCTURAL -PAINT

METAL 'T' FRAMESOLID. INSTALL MIN.3 PER JAMB

HOLLOW METAL FRAMEGROUT FILLED (TYP.)PAINT

CAULK FRAMEPERIMETERTYP. EACH SIDE

HOLLOW METAL FRAMEGROUT SOLID - PAINT

CAULK FRAME PERIMETEREACH SIDE (TYP.)

REFER TOSTRUCTURAL DRWG'S.FOR REINF. LINTEL

8" CMU BLOCK - REFER TOSTRUCTURAL - PAINT

0' -

4"

HEAD JAMB

CAULK FRAME PERIMETERTYP. EACH SIDE

WALL FINISH - REFER TO ROOMFINISH SCHEDULE

3 5/8" METAL STUDS

0' -

2"

HOLLOW METAL FRAME -PAINTED

STUD RUNNER

3 5/8" METAL STUDS

0' -

2"

HOLLOW METAL FRAME -PAINTED

CAULK FRAME PERIMETERTYP. EACH SIDE

WALL FINISH - REFER TO ROOMFINISH SCHEDULE

JAMB STUDS

BATT INSULATION

0' - 3 1/2"

0' - 7"

0' - 2"0' - 2"

0' - 7"

0' - 2" 0' - 3 1/2" 0' - 2"

5' -

4"

5' -

4"

GB36MIN.

1' - 0"

MIN.

2' - 0"

TOP

OF

OPE

R. M

ECH

. LO

WER

FO

R C

HIL

D

48" M

AX.

20"-2

5" F

OR

CH

ILD

33" -

36"

ADU

LT

4' - 6" MIN.

MAX.

1' - 0" GB42

2' -

8" M

AX.

FOR

CH

ILD

20"-

25"

39" -

41"

18" M

IN.

39" - 41"

GB18

0' -

1 1/

2" M

IN.

14"-1

7" C

HIL

D

15" M

IN

2' - 0" MIN.

A3NOTE:DIMENSIONS TO COMPLYWITH THE 2010 ADASTANDARDS AND 2009ANSI STANDARDS

TO

P O

F O

PER

. MEC

H

48" M

AX. T

O

TO R

EF. S

UR

F

3'-4

" MAX

2'-1

0" M

AX

A2

A6

A7

A10 A9

A3

A1A11

A8

A4

A5

2' -

10" M

AX.

7" - 9"

CH

ILD

12" -

15"

STAN

DIN

G P

ERSO

N

38" -

43"

4' -

0"

CH

ILD

REN

24" M

IN

LOW

ER F

OR

CH

ILD

REN

35" M

AX

CH

ILD

24"M

IN

CH

ILD

35" M

AX

1' - 6"

A702

14A -RM 105

CLEAR

60" MIN

CLR

24" MIN

CHILD

12"-15"

CLR

24" M

IN.

CLEAR

5' - 6"

A2

A6

ALIG

N

0' - 6"

A3

27" A

FF

V.I.F.

2' - 5"

FOLD DOWN -VERTCHANGING TABLE

EXISTING CMU WALL EXISTING TOILET PARTITION

EXISTING COUNTER

A1 GRAB BAR 36" BOBRICK B550 SERIES/ 1.5" DIA./CONCEALED MOUNT

A2 HAND SOAP DISPENSER OFCI

A3 CHANNEL FRAME MIRROR BOBRICK B290 18X36

A4 TOILET PAPER DISPENSER TORK 56TR

A5 NAPKIN DISPOSAL BOBRICK B-270

A6 PAPER TOWEL DISPENSER BOBRICK B-262

A7 NOT USED

A8 GRAB BAR 18" BOBRICK B550 SERIES 1.5" DIA./CONCEALED MOUNT

A9 MOP RACK BOBRICK B239 X 34

A10 COAT HOOK BOBRICK B-2216

A11 GRAB BAR 42" BOBRICK B550 SERIES /1.5" DIA/CONCEALED MOUNT

ACCESSORY LEGEND

GENERAL NOTES -REACH RANGES:

1. PROVIDE REACH RANGES FOR CHILDREN PER CURRENT APPLICABLE CODE FOR CHILDREN AGES 3 THROUGH 5 YEARS.

ALUMINUM CURB FRAME-PER MANUF.

1 1/2" WOOD CURB

ALUMINUM CAP -PER MANUF.-SEE MECH. DWGS. FOR CAP SIZES-COORD. WITH SHEET AS101 AND MECH. DWGS.FOR LOCATIONS-CONFIRM FINAL LOCATION WITH ARCHITECTPRIOR TO INSTALLATION

PROVIDE SEALANT AT FLANGE-PER MANUF.

12 EXIST V.I.F.

6

PROVIDE FLASHING AROUND OPENING

EXISTING ROOF AND WALL CONSTRUCTION

PLYWOOD SHEATHING

CUT EXISTING

Pawleys Island / Charleston

S RAG IC H T E C UT R E

COASTALCAROLINA

UNIVERSITYCHILD

DEVELOPMENT& LITERACY

CENTERRENOVATION

Notes:

Revisions:

106 CHANTICLEER DR. EASTCONWAY, SC 29526

Owner:

COASTAL CAROLINA UNIVERSITY# H17-N104-CB

Individual Seal

Corporate Seal

of

COPYRIGHT 2018 ALL RIGHTS RESERVEDPRINTED OR ELECTRONIC DRAWINGS ANDDOCUMENTATION MAY NOT BE REPRODUCEDIN ANY FORM WITHOUT WRITTENPERMISSION FROM SGA ARCHITECTURE

MEMBERS OFTHE AMERICAN INSTITUTE OF ARCHITECTS

Job Number: 17002Date: 02/08/2018Drawn by: HK, GHChecked by: SG

8263 Ocean Hwy.PO Box 1859Pawleys Island, SC 29585Phone: (843) 237-3421Fax: (843) 237-1992www.SGAarchitecture.com

5

5

4321

4321

A

B

C

D

E

F

Architect:

BID SET

2/8/

2018

9:2

6:06

AM

A351BID SET

MISCELLANEOUSDETAILS

1/4" = 1'-0"5 FLOOR TRANSITION

1/2" = 1'-0"3 TYPICAL RESTROOM

1 1/2" = 1'-0"2 DOOR FRAME DETAILS CMU 1 1/2" = 1'-0"4 DOOR FRAME DETAILS GYP

3/8" = 1'-0"TYPICAL MOUNTING HEIGHTS

1/2" = 1'-0"1 FIRST FLOOR -TOILET 105

1/4" = 1'-0"8 106 A EXISTING MENS RESTROOM (WOMENS RESTROOMS -OPP HAND) 1 1/2" = 1'-0"9 GRAVITY VENTILATOR

NOTE:SEE CURRENT ADA REQUIREMENTSFOR FURTHER DESCRIPTION OFFIXTURE AND EQUIUPMENT HEIGHTSAND DIMENSIONS.

REV. # Description Date

Page 14: CCU CHILD DEVELOPMENT AND...architectural site plan architectural a002 a003 d101 a101 a101a a102 a121 a352 a401 a701 a702 site details partition types demolition first plan first floor

CATEGORY ABBREVIATION TYPE MANUFACTURER NOTES

FLOORS BBT-1 BIOBASED TILE AMERICAN BILTRITE, TEXAS GRANITE WHITE/GREY VTG-130, 36" X 36" CLASSROOMSBBT-2 BIOBASED TILE AMERICAN BILTRITE, TEXAS GRANITE MINERAL GREY VTG-133, 24" X 24" CLASSROOMS, CORRIDORSBBT-3 BIOBASED TILE AMERICAN BILTRITE, TEXAS GRANITE ANDROS BLUE VTG-194, 12" X 12" CLASSROOMS, BREAKROOMPFT-1 PORCELAIN TILE DALTILE, THEORETICAL, CREATIVE GRAY TH96, 2X2 MOSAIC RESTROOMSCPT-1 CARPET TILE MILLIKEN, MORAINE, RELIEF REF6-153 ORIGIN, 50CM X 50CM OFFICES, LITERACY CPT-2 CARPET TILE MILLIKEN, MORAINE, RELIEF REF201-229 AERIAL, 50CM X 50CM LITERACYCPT-3 CARPET TILE MILLIKEN, MORAINE, RELIEF REF201-6-153 ORIGIN W/TEAL, 50CM X 50CM OFFICES, LITERACY GT GROUT CUSTOM BUILDING PRODUCTS, #370 DOVE GRAYSC SEALED CONCRETE

WALLS PNT-1 PAINT SHERWIN WILLIAMS, CCU TEAL SEE SPECIFICATIONS FOR PAINT MIXPNT-2 PAINT SHERWIN WILLIAMS, SW6486 REFLECTING POOLPNT-3 PAINT SHERWIN WILLIAMS, SW7631 CITY LOFTPWL-1 PORCELAIN WALL TILE DALTILE, THEORETICAL, CREATIVE GRAY TH96, 12X24 RESTROOMSPWL-2 PORCELAIN WALL TILE DALTILE, THEORETICAL, CREATIVE GRAY TH96, 6X24 RESTROOMSPWL-3 PORCELAIN WALL TILE DALTILE, THEORETICAL, CREATIVE GRAY P-43C9, 3X12 RESTROOMSGT GROUT CUSTOM BUILDING PRODUCTS, #370 DOVE GRAY RESTROOMS

CEILING ACT-1 ACOUSTICAL CEILING TILE BASIS OF DESIGN - ARMSTRONGPNT-4 GYP - PAINT SHERWIN WILLIAMS, SW7007 CEILING BRIGHT WHITE, FLAT RESTROOMS

BASE RB RUBBER BASE JOHNSONITE, 6" TRADITIONAL WALL BASE, 40 BLACKGT GROUT CUSTOM BUILDING PRODUCTS, #370 DOVE GRAY RESTROOMS

TRIM PNT-5 PAINT SHERWIN WILLIAMS, SW7076 CYBER SPACE

MISC SS-1 SOLID SURFACE AVONITE, SILVER COMMET 8585, EASED EDGE COUNTERTOPSLAM-1 CUSTOM MILLWORK FORMICA, PECAN WOODLINE 5883-58 CABINETS

NOTES: 1. ALL CMU BLOCK WALLS TO BE PAINTED SEMI-GLOSS FINISH. 2. ALL GYP WALLS TO BE PAINTED EGGSHELL FINISH.3. ALL TRIM TO BE PAINTED GLOSS FINISH

FINISH LEGEND

NOTES:

1. SEE SHEET D101 AND SHEET A101 FOR FURTHER INFORMATION.2. MATCH NEW DOOR FINISH TO EXISTING DOOR FINISH, ARCHITECT TO SELECT FINISH FROM MANUFACTURER'S STANDARDS.3. EXISTING DOOR HARDWARE TO REMAIN.4. ALL WIRE GLASS SHALL BE REMOVED FROM RATED DOORS (SEE SCHEDULE) FOR NEW FIRELITE GLASS (FIELD VERIFIY EXACT

SIZE & DIMENSIONS) & STOP

2" T

YP.

7' -

0"D1 D2 D3

0' - 3" 0' - 3"

0' -

2"7'

- 0"

TEMPEREDVISION PANELS

0' -

4"

0' -

6"

2' -

10 1

/2"

0' -

7 1/

2"

2' -

2 1/

2"7' -

0"3' - 0"

0' - 2" 0' - 2"

3' - 0"

D4 D5

TEMPEREDVISION PANELS

6' - 0"

7' -

0"0'

- 4"

0' - 2" 0' - 2"OFOI

HALF LITENV LITE

0' -

4"7'

- 0"

SECOND FLOOR21' - 10 1/4"

89

NEW DOOR ANDWINDOWS-SEE FLOOR PLAN& SCHEDULES

4' -

6"

2' - 6" 2' - 8"

MAINTAIN EXISTING AWNING-PATCH AND REPAIR AS NECESSARY

M.O.

ENCLOSE OPG

----4

A003

7' -

4"

8' - 9 1/2"

3232 122

WINDOW SCHEDULE

MARK HEIGHT WIDTH MATERIAL GLAZING COMMENTS

32 4'-0" 2'-6" NEW - HM INSUL. TEMP. IMPACT.

24 48" +/- EXIST 32" +/- EXIST EXIST - HM EXIST REMOVE WIRE GLASS F& I FIRELITE GLAZING AND FRAME - SEE SPECS /088117

31 +/- 3'-0" +/- 3'-6" EXIST - HM RATED CORRIDOR RATED GLAZING OH-45 OR W-60 PER IBC

NOTE: ALL OTHER WINDOWS ARE EXISTING UNLESS NOTED OTHERWISE. WINDOW FLASHING INSTALLED PERSECTION 1405.4 OF 2015 IBC

Pawleys Island / Charleston

S RAG IC H T E C UT R E

COASTALCAROLINA

UNIVERSITYCHILD

DEVELOPMENT& LITERACY

CENTERRENOVATION

Notes:

Revisions:

106 CHANTICLEER DR. EASTCONWAY, SC 29526

Owner:

COASTAL CAROLINA UNIVERSITY# H17-N104-CB

Individual Seal

Corporate Seal

of

COPYRIGHT 2018 ALL RIGHTS RESERVEDPRINTED OR ELECTRONIC DRAWINGS ANDDOCUMENTATION MAY NOT BE REPRODUCEDIN ANY FORM WITHOUT WRITTENPERMISSION FROM SGA ARCHITECTURE

MEMBERS OFTHE AMERICAN INSTITUTE OF ARCHITECTS

Job Number: 17002Date: 02/08/2018Drawn by: HK, GHChecked by: SG

8263 Ocean Hwy.PO Box 1859Pawleys Island, SC 29585Phone: (843) 237-3421Fax: (843) 237-1992www.SGAarchitecture.com

5

5

4321

4321

A

B

C

D

E

F

Architect:

BID SET

2/8/

2018

9:2

6:09

AM

A401BID SET

DOOR ANDFINISH

SCHEDULES ANDDETAILS

Room Finish Schedule

Number Name Floor Finish Base Finish Wall Finish Ceiling Finish Ceiling Height Comments

101 CHILD DEVELOPMENT BBT-1, BBT-2, BBT-3 RB PNT-1, PNT-2, PNT-3 ACT 9' - 2" SEE FLOOR FINISH PLAN FOR TILE INSTALLATION PATTERNAND INTERIOR ELEVATIONS FOR PAINT LOCATIONS

102 RESTROOM PFT-1 PWL-2 PNT-2, PWL-1/PWL-2/PWL-3 PNT-4 8' - 0" SEE INTERIOR ELEVATION FOR TYPICAL WALL TILEINSTALLATION PATTERN

103 HALL BBT-2 RB PNT-3 ACT 8' - 6"103A DIRECTOR CPT-1, CPT-3 RB PNT-3 ACT 8' - 6" SEE FLOOR FINISH PLAN FOR CARPET INSTALLATION

PATTERN103B OFFICE CPT-1, CPT-3 RB PNT-3 ACT 8' - 6"103C OFFICE CPT-1, CPT-3 RB PNT-3 ACT 8' - 6"103D BREAK ROOM BBT-3 RB PNT-3 ACT 8' - 6"104 CHILD DEVELOPMENT BBT-1, BBT-2, BBT-3 RB PNT-1, PNT-2, PNT-3 ACT 9' - 2" SEE FLOOR FINISH PLAN FOR TILE INSTALLATION PATTERN

AND INTERIOR ELEVATIONS FOR PAINT LOCATIONS104A ALCOVE BBT-1 RB PNT-3 ACT 8' - 0"105 RESTROOM PFT-1 PWL-2 PNT-2, PWL-1/PWL-2/PWL-3 PNT-4 8' - 0" SEE INTERIOR ELEVATION FOR TYPICAL WALL TILE

INSTALLATION PATTERN106 EX. MENS EXISTING EXISTING EXISTING EXISTING 9' - 2"107 EX. WOMENS EXISTING EXISTING EXISTING EXISTING 9' - 2"108 EX. IT/ELECTRICAL EXISTING EXISTING GYP-PNT EXISTING 8' - 0" PATCH CEILING & WALLS AS REQ'D108A CLOSET SC RB PNT-3 PNT-4 8' - 0" PATCH CEILING & WALLS AS REQ'D -SEE NOTE: 1109 CHILD DEVELOPMENT BBT-1, BBT-2, BBT-3 RB PNT-1, PNT-2, PNT-3 ACT 9' - 2"110 RESTROOM PFT-1 PWL-2 PNT-1, PNT-2, PNT-3 PNT-4 8' - 0" SEE FLOOR FINISH PLAN FOR TILE INSTALLATION PATTERN

AND INTERIOR ELEVATIONS FOR PAINT LOCATIONS111 CHILD DEVELOPMENT BBT-1, BBT-2, BBT-3 RB PNT-1, PNT-2, PNT-3 ACT 9' - 2" SEE FLOOR FINISH PLAN FOR TILE INSTALLATION PATTERN

AND INTERIOR ELEVATIONS FOR PAINT LOCATIONS112 RESTROOM PFT-1 PWL-2 PNT-2, PWL-1/PWL-2/PWL-3 PNT-4 8' - 0" SEE INTERIOR ELEVATION FOR TYPICAL WALL TILE

INSTALLATION PATTERN114 OFFICE CPT-1, CPT-3 RB PNT-3 ACT 9' - 2" SEE FLOOR FINISH PLAN FOR CARPET INSTALLATION

PATTERN115 LITERACY CPT-1, CPT-2, CPT-3 RB PNT-3 ACT 9' - 2"116 LITERACY CPT-1, CPT-2, CPT-3 RB PNT-3 ACT 9' - 2" SEE FLOOR FINISH PLAN FOR CARPET INSTALLATION

PATTERN117 LITERACY EXISTING EXISTING EXIST-PNT EXISTING 8' - 0"118 CUSTODIAL SC RB PNT-3 PNT-4 9' - 2"119 LITERACY CPT-1, CPT-2, CPT-3 RB PNT-1, PNT-3 EXISTING 8' - 0"120 LITERACY CPT-1, CPT-2, CPT-3 RB PNT-1, PNT-3 EXISTING 8' - 0"121 EX. MECHANICAL EXISTING EXISTING EXISTING EXISTING 9' - 2" NO FINISH WORK122 EX. CALL CENTER EXISTING EXISTING EXISTING EXISTING 9' - 2" NO FINISH WORK123 EX. TOILET EXISTING EXISTING EXISTING EXISTING 9' - 2" NO FINISH WORKC01 CORRIDOR EXISTING EXISTING PNT-1, PNT-2, PNT-3 EXISTING 9' - 0" SEE INTERIOR ELEVATIONS FOR PAINT LOCATIONSC02 CORRIDOR EXISTING EXISTING PNT-1, PNT-2, PNT-3 EXISTING 9' - 0" SEE INTERIOR ELEVATIONS FOR PAINT LOCATIONSC03 HALL BBT-2 RB PNT-3 ACT 9' - 0"C04 HALL BBT-2 RB PNT-3 ACT 9' - 0"C05 HALL BBT-2 RB PNT-3 EXISTING 8' - 0"C06 HALL BBT-2 RB PNT-3 EXISTING 9' - 2"C07 CLOSET BBT-2 RB PNT-3 ACT 8' - 0"S01 EX. STAIR EXISTING EXISTING EXISTING EXISTING 8' - 0"S02 EX. STAIR EXISTING EXISTING EXISTING EXISTING 8' - 0"

Door Schedule

Mark Width Height ThicknessDoor

Material Door FinishFire

Rating Frame TypeFrame

MaterialType

Comments Condition Comments

101 3' - 0" 7' - 0" 0' - 1 3/4" FF D3 EXIST HM EXISTING TO REMAIN102 3' - 0" 7' - 0" 0' - 1 3/4" SCW FF D2 HM103 3' - 0" 7' - 0" 0' - 1 3/4" EXIST D3 EXIST HM EXISTING TO REMAIN103A 3' - 0" 7' - 0" 0' - 1 3/4" SCW FF D3 EXIST HM RE-USE EXISTING DOOR

& FRAME103B 3' - 0" 7' - 0" 0' - 1 3/4" SCW FF D3 EXIST HM RE-USE EXISTING DOOR

& FRAME103C 3' - 0" 7' - 0" 0' - 1 3/4" SCW FF D3 EXIST HM RE-USE EXISTING DOOR

& FRAME103D 3' - 0" 7' - 0" 0' - 1 3/4" SCW FF D3 EXIST HM RE-USE EXISTING DOOR

& FRAME103E 3' - 0" 7' - 0" 0' - 1 3/4" SCW FF D3 EXIST HM RE-USE EXISTING DOOR

& FRAME104 3' - 0" 7' - 0" 0' - 1 3/4" EXIST D4 EXIST HM EXISTING TO REMAIN105 3' - 0" 7' - 0" 0' - 1 3/4" SCW FF D2 HM NEW DOOR & FRAME106 3' - 0" 7' - 0" 0' - 1 3/4" EXIST D2 EXIST HM EXISTING TO REMAIN107 3' - 0" 7' - 0" 0' - 1 3/4" EXIST D2 EXIST HM EXISTING TO REMAIN108 3' - 0" 7' - 0" 0' - 1 3/4" SCW FF D2 HM EXISTING TO REMAIN108A 3' - 0" 7' - 0" 0' - 1 3/4" SCW FF D2 HM108B 3' - 0" 7' - 0" 0' - 1 3/4" SCW FF HM EXISTING TO REMAIN109A 3' - 0" 7' - 0" 0' - 1 3/4" EXIST D4 EXIST HM EXISTING TO REMAIN109B 3' - 0" 7' - 0" 0' - 1 3/4" SCW FF D3 HM110 3' - 0" 7' - 0" 0' - 1 3/4" SCW FF D2 EXIST HM EXISTING TO REMAIN111A 3' - 0" 7' - 0" 0' - 1 3/4" FF D4 HM MATCH EXISTING DOOR

FINISH111B 3' - 0" 7' - 0" 0' - 1 3/4" SCW FF D3 EXIST HM RE-USE EXISTING DOOR

& FRAME112 3' - 0" 7' - 0" 0' - 1 3/4" SCW FF D2 HM114 3' - 0" 7' - 0" 0' - 1 3/4" SCW FF D3 EXIST HM RE-USE EXISTING DOOR

& FRAME115A 3' - 0" 7' - 0" 0' - 1 3/4" SCW FF D3 EXIST HM RE-USE EXISTING DOOR

& FRAME115B 3' - 0" 7' - 0" 0' - 1 3/4" SCW FF D3 EXIST HM RE-USE EXISTING DOOR

& FRAME116 3' - 0" 7' - 0" 0' - 1 3/4" EXIST D3 EXIST HM EXISTING TO REMAIN117 3' - 0" 7' - 0" 0' - 1 3/4" EXIST D3 EXIST HM EXISTING TO REMAIN118 3' - 0" 7' - 0" 0' - 1 3/4" SCW FF D2 HM119 3' - 0" 7' - 0" 0' - 1 3/4" EXIST D3 EXIST HM EXISTING TO REMAIN120 3' - 0" 7' - 0" 0' - 1 3/4" EXIST D3 EXIST HM EXISTING TO REMAIN121 3' - 0" 7' - 0" 0' - 1 3/4" HM EXIST D2 EXIST HM EXISTING TO REMAIN122 3' - 0" 7' - 0" 0' - 1 3/4" HM FF D1 HM123 3' - 0" 7' - 0" 0' - 1 3/4" SCW EXIST D2 EXIST HM EXISTING TO REMAINC01 6' - 0" 7' - 0" 0' - 1 3/4" FF D5 ALUM NEW DOOR OFOIC02A 6' - 0" 7' - 0" 0' - 1 3/4" FF D5 ALUM NEW DOOR OFOI, CARD

READERC02B 6' - 0" 7' - 0" 0' - 1 3/4" FF D5 ALUM NEW DOOR OFOI, CARD

READERC03 3' - 0" 7' - 0" 0' - 1 3/4" EXIST D4 EXIST HM EXISTING TO REMAINC05 3' - 0" 7' - 0" 0' - 1 3/4" SCWC06 3' - 0" 7' - 0" 0' - 1 3/4" HM EXIST D2 EXIST HM EXISTING TO REMAINC07 3' - 0" 7' - 0" 0' - 1 3/4" SCW FF D2 EXIST HM RE-USE EXISTING DOOR

& FRAMES01 3' - 0" 7' - 0" 0' - 1 3/4" EXIST D2 EXIST HM EXISTING TO REMAINS02 3' - 0" 7' - 0" 0' - 1 3/4" EXIST D2 EXIST HM EXISTING TO REMAIN

1/4" = 1'-0"Door Type

NOTE:

1. PROVIDE 1/4" SOLID SURFACE SURROUND AT MOP SINK WALLS, SEE ELEVATION.2. COORDINATE CEILING HEIGHT WITH DUCTWORK, NOTIFY ARCHITECT OF ANY CONFLICTS WITH

CEILING.3. EXISTING CEILINGS DO HAVE INSULATION ABOVE (ATTIC) AND SHOULD BE MAINTAINED

REPLACE ANY INSULATION THAT IS DISTURBED DURING CONSTRUCTION IN ATTIC.4. EXISTING WINDOW BLINDS TO REMAIN. PROTECT DURING CONSTRUCTION.5. EXISTING RECESSED MOTOR PROJECTION SCREEN TO BE REMOVED BY OWNER.6. CEILING FANS TO BE REMOVED BY OWNER.7. MARKER BOARD CABINET TO BE REMOVED BY OWNER.

SCW

SCW

SCW

SCW

ALUMALUM

ALUM

SCW

3/16" = 1'-0"1 EAST ELEVATION

BRICK TO MATCHEXISTING

20 MIN

20 MIN

20 MIN

20 MIN20 MIN20 MIN

20 MIN20 MIN

20 MIN

20 MIN

20 MIN

20 MIN

20 MIN20 MIN45 MIN20 MIN20 MIN

20 MIN

EXIST

20 MIN

SCWSCW

SCWSCW

20 MIN

SCW

SCW

20 MIN

20 MIN20 MIN

SCW

EXIST

20 MIN

20 MINNO WORK

DoorHardware

EXIST0506EXIST

EXIST

EXIST

EXIST

EXIST

0605EXISTEXISTEXIST08EXISTEXIST070506

06

05EXIST

EXIST

EXIST

EXISTEXIST

EXISTEXISTEXIST09100102

03

EXISTEXIST04EXIST

11EXIST

12

REV. # Description Date

Page 15: CCU CHILD DEVELOPMENT AND...architectural site plan architectural a002 a003 d101 a101 a101a a102 a121 a352 a401 a701 a702 site details partition types demolition first plan first floor

11 12

0' - 1 1/2" 3' - 0" 3' - 0"

3' - 1 1/2" 3' - 0"

----

GYP. BD.-PAINT

PNT-3

SS-1

LAM-1

LAM-1

RB

5VERIFY WALL PROXIMITYTO EXISTING WINDOW

3A003

PNT-1

PNT-2

PNT-3

3' -

4"1'

- 4"

4' -

6"

PNT-5 (TYP.)PNT-5 (TYP.)

1112

PNT-3

PNT-2

PNT-1

PNT-3

RB

PNT-5 (TYP.)

3' -

4"1'

- 4"

4' -

6"

EXISTING WINDOWREMOVE GLASS & FIELD VERIFY EXACTDIMENSIONS REPLACE GLAZING W/FIRELITE

24 24

FIRST FLOOR10' - 0"

3' -

0"

COAT HOOKS

CUBBIES

3A003

PNT-3

LAM-1

RB

8

PNT-2

PNT-1

PNT-3

3' -

4"1'

- 4"

4' -

6"0'

- 2

1/2"

56

PNT-3

PNT-2

PNT-1 RB

PNT-5 (TYP.)

4' -

6"1'

- 4"

3' -

4"

FIRST FLOOR10' - 0"

8

RB

PNT-3 PNT-3PNT-3

56

3' - 0" 9' - 1 1/2"

9' - 1 1/2"3' - 0"3' - 0"

COAT HOOKS

CUBBIES

3A003

PNT-3PNT-3

PNT-3

LAM-1SS-1

LAM-1LAM-1

RB

18

A702 NEW &EXIST. GYP BD-PAINT, TYP.

EXIST CMU-PAINT, TYP.

PNT-3

PNT-2 PNT-1

LAM-1

?

SS-1

LAM-1

PNT-2

LAM-1RB

PNT-3

810

PNT-3

PNT-2

PNT-1

LAM-1 RB

3' -

4"1'

- 4"

4' -

6"

PNT-5 (TYP.)

FIRST FLOOR10' - 0"

1 2

PNT-3

PNT-2

PNT-1RB

PNT-5 (TYP.)0' -

2 1/

2"4'

- 6"

1' -

4"3'

- 4"

8

RB

PNT-3

PNT-3

PNT-2

PNT-1RB

PNT-5 (TYP.)

3' -

4"1'

- 4"

4' -

6"

1

CUBBIES

DOOR HOOKS

PNT-3

PNT-2

PNT-1 RB

LAM-1

PNT-3

PNT-5 (TYP.)

6A702

FILLER0' - 2" 3' - 0" 3' - 0"

3' - 1 1/2" 3' - 0"

RB

LAM-1

LAM-1

PNT-3

PNT-2

1

VERIFY WALL PROXIMITYTO EXISTING WINDOW

PNT-3

PNT-2

PNT-1

3' -

4"1'

- 4"

4' -

6"

FIRST FLOOR10' - 0"

8

PNT-3

RB

Pawleys Island / Charleston

S RAG IC H T E C UT R E

COASTALCAROLINA

UNIVERSITYCHILD

DEVELOPMENT& LITERACY

CENTERRENOVATION

Notes:

Revisions:

106 CHANTICLEER DR. EASTCONWAY, SC 29526

Owner:

COASTAL CAROLINA UNIVERSITY# H17-N104-CB

Individual Seal

Corporate Seal

of

COPYRIGHT 2018 ALL RIGHTS RESERVEDPRINTED OR ELECTRONIC DRAWINGS ANDDOCUMENTATION MAY NOT BE REPRODUCEDIN ANY FORM WITHOUT WRITTENPERMISSION FROM SGA ARCHITECTURE

MEMBERS OFTHE AMERICAN INSTITUTE OF ARCHITECTS

Job Number: 17002Date: 02/08/2018Drawn by: HK, GHChecked by: SG

8263 Ocean Hwy.PO Box 1859Pawleys Island, SC 29585Phone: (843) 237-3421Fax: (843) 237-1992www.SGAarchitecture.com

5

5

4321

4321

A

B

C

D

E

F

Architect:

BID SET

2/8/

2018

9:2

6:10

AM

A701BID SET

INTERIORELEVATIONS

3/16" = 1'-0"1 109 A 3/16" = 1'-0"2 109 B

3/16" = 1'-0"3 109 C 3/16" = 1'-0"4 109 D

3/16" = 1'-0"5 111 A 3/16" = 1'-0"6 111 B

3/16" = 1'-0"7 111 C

3/16" = 1'-0"8 111 E 3/16" = 1'-0"9 101 A

3/16" = 1'-0"10 101 B 3/16" = 1'-0"11 101 C

3/16" = 1'-0"12 101 D 3/16" = 1'-0"13 104 A

3/16" = 1'-0"14 104 B 3/16" = 1'-0"15 104 C

3/16" = 1'-0"16 104 D

CUBBIES

3/16" = 1'-0"17 111 D

REV. # Description Date

Page 16: CCU CHILD DEVELOPMENT AND...architectural site plan architectural a002 a003 d101 a101 a101a a102 a121 a352 a401 a701 a702 site details partition types demolition first plan first floor

4 5

3A003

4' -

6"1'

- 4"

3' -

4"PNT-3

PNT-2

PNT-1 RB

PNT-1

PNT-1

PNT-5 (TYP.)

45

EXISTING DRINKING FOUNTAIN

EXISTING FIRE EXTINGUISHER

3A003

3' -

4"1'

- 4"

4' -

6"

PNT-1

PNT-3

PNT-1

PNT-2 PNT-1

PNT-3

PNT-2

PNT-1RB

PNT-5 (TYP.)NEW RMS PANEL

NEW FAAP PANEL

SEE ELECTRICAL DRAWINGS

FIRST FLOOR10' - 0"

2' -

10"

1' -

8"2'

- 6"

CEILING - SEE SCHED.

PLAM - LAM-1 (SEE FINISH SCHEDULE)

WIRE PULL HANDLE

SOLID SURFACE COUNTERW/ INTEGRAL BACKSPLASHSS-1 (SEE FINISH SCHEDULE)

WIRE PULL HANDLE

TOE-KICK, PROVIDE WALL BASE RB-SEE FINISH SCHEDULE

ADJ. SHELVING

DRAWER WITH WIRE PULL

GYP BD BULKHEAD ABOVE CASEWORK-PNT-2 TYP.

0' -

4"

SEALANT -COLOR TO MATCH PLAM

2' -

1 1/

2"

0' -

0 1/

2"

0' -

3 1/

2" 0' -

1 1/

2"

ADJ. SHELVING

10

3' - 0" 2' - 0" 0' - 2"

2' - 0" 0' - 2"

7A702

PNT-2

PNT-3 PNT-3

SS-1

RB

LAM-1

LAM-1

FIRST FLOOR10' - 0"

2' -

6"1'

- 4"

0' -

4"2'

- 10

"

0' -

1 1/

2"

0' -

1"0'

- 4

1/2"

(2) E

Q D

WR

S

0' -

0 1/

2"

0' -

10 1

/2"

SOLID SURFACE COUNTERW/ INTEGRAL BACKSPLASHSS-1 (SEE FINISH SCHEDULE)

WIRE PULL HANDLE

PLAM - LAM-1 (SEE FINISH SCHEDULE)

SEALANT - COLOR TO MATCH PLAM

GYP BD BULKHEAD ABOVE CASEWORK-PNT-2 TYP. (PROVIDE FIRESTOP BLOCKING)

CEILING -SEE SCHED.

ADJ. SHELVING

FIRST FLOOR10' - 0"

CEILING - SEESCHED.GYP BD BULKHEAD ABOVE CASEWORK-PNT-2 TYP. (PROVIDE FIRESTOP BLOCKING)

SOLID SURFACE COUNTERW/ INTEGRAL BACKSPLASHSS-1 (SEE FINISH SCHEDULE)

STAINLESS STEEL SINK, SEE SCHED.W/ ADA COMPLIANT FAUCET

WIRE PULL HANDLE

TOE-KICK, PROVIDE BASERB-SEE FINISH SCHEDULE

LIGHT FIXTURE, SEE SCHEDULE

2' -

10"

91011

9' -

2"

?

?

? RB

PNT-2

PNT-3

PNT-2

PNT-1

PNT-1

PNT-3

PNT-2

PNT-1

PNT-1

PNT-3

PNT-2

PNT-1

PNT-3

PNT-2

PNT-1

PNT-5 (TYP.)

9 10 11

NEW DRINKING FOUNTAIN& BOTTLE FILLING STATION

EXISTING WINDOWREMOVE GLASS & FIELD VERIFY EXACTDIMENSIONS REPLACE GLAZING W/FIRELITE

EXIST. GYP. BD.-PAINT, TYP.

EXIST. CMU-PAINT

3' -

4"1'

- 4"

4' -

6"PNT-3

PNT-2

PNT-1 RB

PNT-1

PNT-1 PNT-1PNT-3

PNT-2

PNT-1

24 24 24

6

PNT-3

RB

3131

AFF

24" M

IN

LAVATORY AT CHILDRENSTOILET ROOM-HEIGHTS PER CURRENT ADA-COORD. HEIGHT W/ OWNER/ARCHITECTPRIOR TO INSTALL

TOILETPER ADA (FOR 5 YEAR OLDS)-SEE PLUMBING DWGS.

FULL HEIGHT - PORCELAIN TILEAT WET WALL(5'-0" AFF AT OTHER WALLS)

PWL-2

PWL-1

PWL-2 PWL-1

PWL-2PWL-1

PWL-2

0' -

6"1' -

0"

1' -

6"0' -

3"

PWL-2

PWL-1

PWL-3PWL-2

PWL-2

PWL-1

PWL-2PWL-3

PWL-2PWL-1

PWL-2PWL-3

AFF

24" M

IN

LAVATORY AT CHILDRENSTOILET ROOM-HEIGHTS PER CURRENT ADA-COORD. HEIGHT W/ OWNER/ARCHITECTPRIOR TO INSTALL

FULL HEIGHT - PORCELAIN TILEAT WET WALL (5'-0" AFF AT OTHER WALLS)

PWL-2

PWL-1

PWL-2PWL-1

0' -

6"2'

- 0" 0'

- 6"

2' -

0" 0' -

6"

PWL-2PWL-1

6' -

0"

Pawleys Island / Charleston

S RAG IC H T E C UT R E

COASTALCAROLINA

UNIVERSITYCHILD

DEVELOPMENT& LITERACY

CENTERRENOVATION

Notes:

Revisions:

106 CHANTICLEER DR. EASTCONWAY, SC 29526

Owner:

COASTAL CAROLINA UNIVERSITY# H17-N104-CB

Individual Seal

Corporate Seal

of

COPYRIGHT 2018 ALL RIGHTS RESERVEDPRINTED OR ELECTRONIC DRAWINGS ANDDOCUMENTATION MAY NOT BE REPRODUCEDIN ANY FORM WITHOUT WRITTENPERMISSION FROM SGA ARCHITECTURE

MEMBERS OFTHE AMERICAN INSTITUTE OF ARCHITECTS

Job Number: 17002Date: 02/08/2018Drawn by: HK, GHChecked by: SG

8263 Ocean Hwy.PO Box 1859Pawleys Island, SC 29585Phone: (843) 237-3421Fax: (843) 237-1992www.SGAarchitecture.com

5

5

4321

4321

A

B

C

D

E

F

Architect:

BID SET

2/8/

2018

9:2

6:13

AM

A702BID SET

INTERIORELEVATIONS &

CASEWORK

3/16" = 1'-0"1 CO1 3 - a 3/16" = 1'-0"2 C01 3 - c

3/4" = 1'-0"6 SECTION - TYP CASEWORK

3/16" = 1'-0"5 103D A

3/4" = 1'-0"7 SECTION -TYP CASEWORK WITH DWRS 3/4" = 1'-0"8 SECTION - TYP CASEWORK WITH SINK

3/16" = 1'-0"3 C02 1 - a 3/16" = 1'-0"4 C02 1 - c

3/16" = 1'-0"9 C05 A

1/4" = 1'-0"14 A -RM 105

1/4" = 1'-0"11 1 - b 1/4" = 1'-0"12 1 - c

1/4" = 1'-0"13 1 - d 1/4" = 1'-0"10 A-TYP RM

REV. # Description Date