Upload
lydieu
View
220
Download
1
Embed Size (px)
Citation preview
PM-7000 Patient Monitor
PM-7000
Patient Monitor
Sidestream EtCO2
Microstream EtCO2
For intubated and non-intubated adult, pediatricReusable and durable water trap, protects the gas analyzer from humidity, mucus and bacteria
For intubated and non-intubated useFlexible for adult, pediatric, infant/neonateOne-piece plug and play consumables
Illuminates when an alarm is triggered withconspicuous color: yellow or red
Alarm light
Bedrail hook with slide proof designHandle/bedrail hook
External Multi-GAS module
Parameters: ECG, RESP, NIBP, SpO2, TEMP, IBP, CO, EtCO2, AG
10.4''color TFT with maximum 8 waveforms
MasimoSET / Nellcor OxiMax / Mindray SpO2
SpO2 pulse-tone modulation (Pitch Tone)
12-lead ECG analysis
Adjustable 10-level alarm sound
Microstream EtCO2 (Oridion)/ Sidestream EtCO2 (Mindray)/Mainstream EtCO2(Welch Allyn)
Nurse call connection available
Optional Li-ion battery
Large numeric for visibility from distance
LAN/ Wireless LAN connection
Adopting infrared absorption techniqueto measure the concentration of EtCO2,N2O and five other anesthesia gases,including Des, Iso, Enf, Sev, Hal. O2 isalso available.
Multi-Gas/O2 Measuring
Basic parameters (ECG, SpO2, NIBP, )In large font for distance view
Large Font Display ModeComprehensive review of monitoringinformation obtaining access to 96-hourtrend graph of all parameters and 40''full-disclosure waveforms
Trend GraphDisplay of real-time waveforms and vitaldata produced prior to, during and afterthe occurrence of Arrhythmia events
Comprehensive Arrhythmia Review
Technical Specifications
PM-7000
P/N:ENG-PM7000-420285-20070122
MasimoSET is a registered trademark or a trademark of Masimo corporation.
Safety NIBP
Dimension and Weight
Operation Environment
Patient RangeTemperature
Performance Specifications
Mindray SpO2
TMMasimo SET SpO2
ECG
Nellcor SpO2
IBPExternal Muti-Gas/O2
CO
Respiration
Meet the requirements of IEC60601 series, CE marking according Method: Oscillometricto MDD93/42/EEC Operation modes: Manual/Automatic/STAT
Measurement unit: mmHg/kPa selectableMeasurement types: Systolic, Diastolic, Mean
Dimension: 310mm (W) x 280mm (H) x 150mm (D) Measurement range: Adult: 10-270mmHgWeight: 5.5kg (not including external Pediatric: 10-200mmHg
Multi-gas module) Neonatal: 10-135mmHgOver-pressure protection: YESResolution: 1mmHg
Power: AC100-240V, 50/60 Hz Accuracy: Mean error and standard Temperature: 0-40 deviation perHumidity: 15-95% ANSI/AAMI SP-10
Alarm: Systolic, Diastolic, Mean
Adult, pediatric and neonatalMeasurement range: 0-50 BrPM BrPMResolution: 0.1
BrPM BrPMDisplay: 10.4" color TFT(diagonal) Accuracy: 0.1 (not including probe)BrPM BrPMResolution: 800x600 Channel: Dual-channel
Trace: 8 waveforms Alarm range: 0-50Sweep speed: 6.25mm/s, 12.5mm/s, 25mm/s, 50mm/s
Indicator: Alarm indicatorPower indicator Measurement range: 0~100%QRS beep and alarm sound Resolution: 1%
Interface: Net Port Accuracy: 2% (70-100% Adult/Pediatric non-motion);Battery: Rechargeable 3% (70-100% Neonate non-motion);Lead-Acid: 75 minutes for continuous working 3% (70-100% Adult/Pediatric/NeonateLithium-ion: 150 minutes for continuous working motion);Trend time: 0-96 hours 0-69% unspecifiedAlarm: 3-level audible and visual alarm Alarm range: 0~100%Networking: LAN/Wireless LAN to Mindray Central Staion Pulse rate: Range: 20~254bpmWireless LAN: Operates on license free ISM (Industrial, Resolution: 1bpm
Scientific and Medical) 2.4 ~ 2.483 GHz radio Accuracy: 3bpm non-motionfrequency band IEEE 802.11b compliant 5bpm motion
Recorder: Built-in, thermal array, 2 channels Alarm range: 20~254bpm BrPMRecord width: 48mm, (record paper 50mm) BrPMRecord speed: 25mm/s, 50mm/s
BrPMRangeSaturation (SpO2): 1-100%Pulse Rate: 25-240 bpmAdultSpO2 Range: 70%-100% 0% to 69%Accuracy ( 1Std. Dev.)*: 2 digits UnspecifiedPulse Rate Range: 25-240 bpmAccuracy ( 1Std. Dev.)*: 3 bpmNeonateSpO2 Range: 70%-95% 0% to 69%Accuracy ( 1Std. Dev.)*: 3 Digits UnspecifiedPulse Rate Range: 25-240 bpm
2Accuracy ( 1Std. Dev.)*: 3 bpm(non-motion)
2 5 bpm(motion)BrPM
2
Measurement Range 2
SpO2: 0~100% BrPMPulse Rate: 20 ~ 300 bpm
2AccuracySaturation (% SpO2 SD): 70% to 100% *
0% to 69% unspecifiedPulse rate: 20 to 250 bpm 3 digits BrPM
251to 300 bpm unspecified
Measurement range: -50~300mmHgChannel: 2 channels Method: Infrared AbsorptionPressure transducer: Sensitivity: 5 V/V/mmHg Gas sorts: EtCO2, N2O, Des, Iso, Enf, Sev,Impedance range: 300-3000 Hal O2 (optional, paramagnetic Transducer sites: ART, PA, CVP, RAP, LAP, ICP sensor)Measurement unit: mmHg/kPa selectable Measurement range: EtCO2: 0~30%(0~76mmHg)Resolution: 1mmHg N2O: 0~105%Accuracy: 1mmHg or 2%, whichever greater O2: 0~100%Alarm range: -10~300mmHg Enf, Iso, Hal: 0~30%
Sev: 0~30%Des: 0~30%
Method: Thermodilution AwRR: 2-100BrPMMeasurement range: CO: 0.1-20 l./min. Resolution: CO2: 0.1% (1mmHg)
TB: 23-43 N2O: 1%TI: 0-27 O2: 0.1% (1mmHg)
Resolution: CO: 0.1 l./min. Enf, Iso, Hal, Sev, Des: 0.01%Temperature: 0.1 Resp rate: 1BrPMAccuracy: CO: 5% or 0.1l./min.Method: Thoracic impedance Data output: Fi and Et Values
TB: 0.1Operation modes: Auto/ Manual Respiration rate: 4~60 1BrPMTI: 0.1Measurement range: Adult: 0~120BrPM; Neonate/Pediatric: 0~150BrPM Other: Up to 4 waveforms displayed
Apnea alarm: YES Agent mixture detectionAlarm: YES, audible and visual alarm, alarm events recallable MAC value displayedApnea alarm: YES
0-38 mmHg 2 mmHg39-99 mmHg 5% of reading + 0.08% for every 1 mmHg(above 38 mmHg)
Resolution Waveform: 0.1mmHgValue: 1 mmHg
Sampling rate 50ml/min -7.5+15ml/minInitialization time 30 seconds (typical), reaches 5% steady-state
accuracy within 3minutes.Response time Typical value: 2.9s, including the rising time and the
delay time (adopting the FilterLine of standard length)
Rising time: <190ms(rising from 10% to 90%)Delay time: 2.7s (typical value)Respiration rate 0-150 breaths/minRespiration rate accuracy 0 70 1
71 120 2121 150 3
Mode Adult, neonate
CO2 measurement range 0-99mmHgAccuracy 2mmHg (0-40 mmHg)
5% of reading (41-76 mmHg)10% of reading (77-99 mmHg)
Sampling rate 100 ml/min,150ml/minSampling rate accuracy 15%Start-up time <1min, once the module starts up, it reaches ISO
Accuracy Mode 10 minutes after start-up, the module reaches full
accuracy modeRespiration rate 0-120 Respiration rate accuracy 2 rpm (0-70 )
5 rpm(>70 )Response time <240 msec (10% to 90 %)Delay time < 2s5-lead and 3-lead selectable,12-lead(including 3/5-lead) optional
(Sampling line length: 7 inches; internal diameter: 0.055 Input: 10 leadwire cable: RA; LA; RL; LL; V1-V6 or R; L; N; F; C1-C6 Inches; sampling gas flow rate:
150ml/min)5 leadwire cable: RA; LA; RL; LL; V or R; L; N; F; C
3 leadwire cable: RA; LA; LL or R; L; F
Method: Infrared AbsorptionLead selection: 12-lead: I; II; III; avR; avL; avF; V1-V6Measuring Mode: Mainstream 5-lead: I; II; III; avR; avL; avF; V(n)Measurement range: EtCO : 0-99mmHg 3-lead: I; II; III
InsCO : 0-99mmHgECG waveform: 2 channelsAwRR: 0-150 Gain selection: x0.125;x0.25; x0.5; x1; x2; auto
Resolution: EtCO : 1mmHgSweep speed: 12.5mm/s, 25mm/s, 50mm/sInsCO : 1mmHgHeart Rate range: Adult: 15-300 bpm; AwRR: 1Neonate/ Pediatric: 15-350 bpm
Accuracy: CO concentration: 2mmHg (0-40mmHg)Accuracy: 1bpm or 1%, whichever is greater 5% of reading (41-76mmHg)Resolution: 1bpm 10% of reading (77-99mmHg)Filter: Diagnostic mode: 0.05-100Hz or 0.05-AwRR: 2150Hz(optional
Alarm range: Same as Measurement range12-lead) Monitoring mode: 0.5-40 HzSurgical mode: 1-20Hz
Protection: Withstand 4000VAC/50Hz voltage in isolation Against electrosurgical interference and defibrillation
Scaling signal: 1mV 5%Alarm range: 15-350 bpmS-T segment detection: Measurement range: -2.0mV~2.0mV
Alarm range: -2.0mV~2.0mVArrhythmia analysis: YESAlarm: YES, audible and visual alarm,
Alarm events recallable12 lead ECG analysis: YESPace detection YES
CO2 range 0-99mmHgAccuracy:
Sidestream CO2
Mainstream CO2
Microstream CO2
Testing is based on healthy adult volunteers in induced hypoxia studies with LNOP*Adt sensors; during no motion.Testing to verify saturation specification is done against a CO-Oximeter. Testing to verify pulse rate specification is done against an ECG monitor.**Languages: Chinese, English, French, German, Italian, Spanish, Portuguese, Polish, Russian, Turkish, Czech, Danish, Finnish, Dutch, Hungarian
Standard configurations: Optional configurations:
ECG, RESP, NIBP, Mindray SpO2, TEMP, BatteryTMsimo SET SpO2, 2-IBP, CO, EtCO2, External Multi-Gas/O2, Thermal Recorder12-Lead ECG,Ma