Upload
uchuk-pabbola
View
214
Download
0
Embed Size (px)
Citation preview
7/25/2019 Photometer HI83203
1/1
www.hannainst.com
10
Photometers
b
ench
10.11
Test Range Method Reagents
Ammonia LR 0.00 to 3.00 mg/L (ppm) Nessler HI93700-01
Ammonia MR 0.00 to 10.00 mg/L (ppm) Nessler HI93715-01
Chlorine*, Free 0.00 to 2.50 mg/L (ppm) DPD HI93701-01
Chlorine*, Total 0.00 to 3.50 mg/L (ppm) DPD HI93711-01
Copper HR 0.00 to 5.00 mg/L (ppm) bicinchoninate HI93702-01
Copper LR 0 to 1000 g/L bicinchoninate HI95747-01
Nitrate 0.0 to 30.0 mg/L (ppm) cadmium reduction HI93728-01
Nitrite HR 0 to 150 mg/L (ppm) ferrous sulfate HI93708-01
Nitrite LR 0.00 to 1.15 mg/L (ppm) diazotization HI93707-01
Oxygen, Dissolved (DO) 0.0 to 10.0 mg/L (ppm) Winkler HI93732-01
pH 6.5 to 8.5 pH phenol red HI93710-01
Phosphate HR 0.0 to 30.0 mg/L (ppm) amino acid HI93717-01
Phosphate LR 0.00 to 2.50 mg/L (ppm) ascorbic acid HI93713-01
OrderingInformation
HI83203-01 (115V) and HI83203-02(230V) are supplied with sample cuvettes andcaps (2 ea.), cloth for wiping cuvettes, 60 mL glass bottle for dissolved oxygen analysis,
scissors, AC/DC power adapter, and instruction manual.
HI83203
MultiparameterPhotometer for
Aquaculture Methods 13 measurement methods
Help feature
Full tutorial available in st art up menu
Connectivity
PC compatible via USB
With the ever increasing depletion of fish
stocks in the open seas, aquaculture has
gained prominence and can prove essential
to our future dietary needs. Monitoring and
controlling parameters such as the oxygenlevel as well as pH and nitrate content
in water is vital in ensuring profitable
fish production.
Accurate control can prevent disease,
increase production and even reduce the
premiums on crop insurance. Research
personnel, fish farm operators and wildlife
specialists now have one compact and easy
to use meter to keep a close tab on the most
important parameters in aquaculture.
The HI83203 is a multiparameter bench
meter that measures thirteen methods
essential for aquaculture analysis.
The optical system of HI83203 is based on
special subminiature tungsten lamps and
narrow-band interference filters to guarantee
both high performance and reliable results.
The HI83203 has a powerful interactive
user support that assists the user during the
analysis process. A full tutorial is available
in the Setup Menu, and the Help Menu
provides assistance for every step in the
measurement process. This meter can be
connected to a PC via a USB cable, where
the data can be managed with optionalHI92000 Windows compatible software.
Reagents are available in liquid or powder form, and the amount of each reagent isprecisely dosed to ensure maximum repeatability. Unless noted otherwise, all reagent codes ending with -01 are for 100 tests.
Replace the -01 with -03 for 300 tests.
* For Chlorine measurements, liquid reagents are available
Standard reagents begin on page 10.70; general accessories begin on page 10.8