Photometer HI83203

Embed Size (px)

Citation preview

  • 7/25/2019 Photometer HI83203

    1/1

    www.hannainst.com

    10

    Photometers

    b

    ench

    10.11

    Test Range Method Reagents

    Ammonia LR 0.00 to 3.00 mg/L (ppm) Nessler HI93700-01

    Ammonia MR 0.00 to 10.00 mg/L (ppm) Nessler HI93715-01

    Chlorine*, Free 0.00 to 2.50 mg/L (ppm) DPD HI93701-01

    Chlorine*, Total 0.00 to 3.50 mg/L (ppm) DPD HI93711-01

    Copper HR 0.00 to 5.00 mg/L (ppm) bicinchoninate HI93702-01

    Copper LR 0 to 1000 g/L bicinchoninate HI95747-01

    Nitrate 0.0 to 30.0 mg/L (ppm) cadmium reduction HI93728-01

    Nitrite HR 0 to 150 mg/L (ppm) ferrous sulfate HI93708-01

    Nitrite LR 0.00 to 1.15 mg/L (ppm) diazotization HI93707-01

    Oxygen, Dissolved (DO) 0.0 to 10.0 mg/L (ppm) Winkler HI93732-01

    pH 6.5 to 8.5 pH phenol red HI93710-01

    Phosphate HR 0.0 to 30.0 mg/L (ppm) amino acid HI93717-01

    Phosphate LR 0.00 to 2.50 mg/L (ppm) ascorbic acid HI93713-01

    OrderingInformation

    HI83203-01 (115V) and HI83203-02(230V) are supplied with sample cuvettes andcaps (2 ea.), cloth for wiping cuvettes, 60 mL glass bottle for dissolved oxygen analysis,

    scissors, AC/DC power adapter, and instruction manual.

    HI83203

    MultiparameterPhotometer for

    Aquaculture Methods 13 measurement methods

    Help feature

    Full tutorial available in st art up menu

    Connectivity

    PC compatible via USB

    With the ever increasing depletion of fish

    stocks in the open seas, aquaculture has

    gained prominence and can prove essential

    to our future dietary needs. Monitoring and

    controlling parameters such as the oxygenlevel as well as pH and nitrate content

    in water is vital in ensuring profitable

    fish production.

    Accurate control can prevent disease,

    increase production and even reduce the

    premiums on crop insurance. Research

    personnel, fish farm operators and wildlife

    specialists now have one compact and easy

    to use meter to keep a close tab on the most

    important parameters in aquaculture.

    The HI83203 is a multiparameter bench

    meter that measures thirteen methods

    essential for aquaculture analysis.

    The optical system of HI83203 is based on

    special subminiature tungsten lamps and

    narrow-band interference filters to guarantee

    both high performance and reliable results.

    The HI83203 has a powerful interactive

    user support that assists the user during the

    analysis process. A full tutorial is available

    in the Setup Menu, and the Help Menu

    provides assistance for every step in the

    measurement process. This meter can be

    connected to a PC via a USB cable, where

    the data can be managed with optionalHI92000 Windows compatible software.

    Reagents are available in liquid or powder form, and the amount of each reagent isprecisely dosed to ensure maximum repeatability. Unless noted otherwise, all reagent codes ending with -01 are for 100 tests.

    Replace the -01 with -03 for 300 tests.

    * For Chlorine measurements, liquid reagents are available

    Standard reagents begin on page 10.70; general accessories begin on page 10.8