29
MONS, BELGIUM OCTOBER 2003 NOBUYOSHI KITAMURA UW-MADISON / SSEC PMT High Voltage Power Supply Status Nobuyoshi Kitamura University of Wisconsin-Madison

PMT High Voltage Power Supply Status - user-web.icecube

  • Upload
    others

  • View
    6

  • Download
    0

Embed Size (px)

Citation preview

Page 1: PMT High Voltage Power Supply Status - user-web.icecube

MONS, BELGIUM OCTOBER 2003 NOBUYOSHI KITAMURA UW-MADISON / SSEC

PMT High Voltage Power Supply Status

Nobuyoshi Kitamura

University of Wisconsin-Madison

Page 2: PMT High Voltage Power Supply Status - user-web.icecube

MONS, BELGIUM OCTOBER 2003 NOBUYOSHI KITAMURA UW-MADISON / SSEC

Overview

PMT HV Base Board

PMTDigital Optical Module Main Board(DOMMB)

DigitalcontrolPower

PMTAnodesignal

Digital Interface Analog Interface

Highvoltage

Page 3: PMT High Voltage Power Supply Status - user-web.icecube

MONS, BELGIUM OCTOBER 2003 NOBUYOSHI KITAMURA UW-MADISON / SSEC

The Three Prototypes

“Old Iseg”—Aug. 2002 prototypes

“New Iseg”—Split ground implemented.

“EMCO”—Passive base approach consisting of three components:Passive base, HV generator, & digital interface.

Jumper pads

Digital interface boardHV generator

Passive base

Ribbon connector

Jumper pads

Page 4: PMT High Voltage Power Supply Status - user-web.icecube

MONS, BELGIUM OCTOBER 2003 NOBUYOSHI KITAMURA UW-MADISON / SSEC

Photos

EMCO Passive Base“New Iseg”

HV Control Board EMCO HV Generator

Page 5: PMT High Voltage Power Supply Status - user-web.icecube

MONS, BELGIUM OCTOBER 2003 NOBUYOSHI KITAMURA UW-MADISON / SSEC

Treat Them Equally

Every effort was made to make the DOMMB interface uniform among the three prototypes.

Page 6: PMT High Voltage Power Supply Status - user-web.icecube

MONS, BELGIUM OCTOBER 2003 NOBUYOSHI KITAMURA UW-MADISON / SSEC

Chronology—2003

Feb. 20 EMCO reps visit UW-Madison

Mar. 11 Iseg head visits DESY / Zeuthen

Apr. 28 EMCO generators (20) and bases (20) arrive

May 9 Operate EMCO generator with DOMMB29 New Iseg bases arrive (8)

June 24 New Iseg bases arrive (22)

July 23-24 LBNL Workshop ”Old Iseg will do!”

Aug. 12 IceCube report on proto evaluation by NK14 Comments on proto sent to Iseg22 Request for technical information from Iseg26 The “crack incident”

Sep. 8 NK report ”Refocus on EMCO”19 Trip to EMCO

Oct. 1 PO for samples (4) sent to EMCO

Page 7: PMT High Voltage Power Supply Status - user-web.icecube

MONS, BELGIUM OCTOBER 2003 NOBUYOSHI KITAMURA UW-MADISON / SSEC

The Three Prototypes (summary)

Old Iseg or New Iseg?New Iseg with isolated grounds performs badlyNew Iseg with directly connected grounds performs badlyNew Iseg with 1MΩ jumper performs very similarly to Old IsegOld Iseg is cheaper than New IsegOld Iseg consumes less power then New Iseg

Old Iseg

Iseg or EMCO?Both have similar noise levelsVdy1 is fixed in Iseg approachIseg is cheaper than EMCO

Iseg

Trouble with the “New Iseg”

Page 8: PMT High Voltage Power Supply Status - user-web.icecube

MONS, BELGIUM OCTOBER 2003 NOBUYOSHI KITAMURA UW-MADISON / SSEC

New Iseg--Isolated GroundOutput voltage is very unstable with no ground-connecting jumper

Data by John Kelly(hv_2000_iseg_psl.pdf)

Previously reported at LBNL Workship (July 23-24, 2003)

N. Kitamura 7/23/2003

Page 9: PMT High Voltage Power Supply Status - user-web.icecube

MONS, BELGIUM OCTOBER 2003 NOBUYOSHI KITAMURA UW-MADISON / SSEC

Connecting Grounds with a Zero Ω Jumper

Previously reported at LBNL Workship (July 23-24, 2003)

N. Kitamura 7/23/2003

Page 10: PMT High Voltage Power Supply Status - user-web.icecube

MONS, BELGIUM OCTOBER 2003 NOBUYOSHI KITAMURA UW-MADISON / SSEC

Comparison using DOMMB ATWD

http://www.ssec.wisc.edu/~kitamura/HVstatus081203/PMTBaseComparisonWithATWD1.pdf

Page 11: PMT High Voltage Power Supply Status - user-web.icecube

MONS, BELGIUM OCTOBER 2003 NOBUYOSHI KITAMURA UW-MADISON / SSEC

Noise Comparison

All the bases have similar random noise levels observed at the secondary side of the signal coupling transformer.

215 ± 31208 ± 18214 ± 18µVrms

1.12 ± 0.211.26 ± 0.131.22 ± 0.13mVppNOISE AT OUTPUT*

EMCOISEG NEWISEG OLD

*At 50Ω oscilloscope input using a 50Ω cable. 100 nsec window (400 pts.)The scope background is 1mVpp, 190µVrms over 100 nsec.

Previously reported at LBNL Workship (July 23-24, 2003)

N. Kitamura 7/23/2003

Page 12: PMT High Voltage Power Supply Status - user-web.icecube

MONS, BELGIUM OCTOBER 2003 NOBUYOSHI KITAMURA UW-MADISON / SSEC

Overall Comparison

1.12 ± 0.211.26 ± 0.131.22 ± 0.13mVppNOISE AT OUTPUT*

EMCOISEG NEWISEG OLD

~600~260~150COST (US$)

250280130POWER AT MAX OUTPUT (mW)

SCALE WITH OUTPUT

FIXED (600V)1ST DYNODE VOLTAGE

215 ± 31208 ± 18214 ± 18µVrms

*At 50Ω oscilloscope input using a 50Ω cable. 100 nsec window (400 pts.)The scope background is 1mVpp, 190µVrms over 100 nsec.

Previously reported at LBNL Workship (July 23-24, 2003)

N. Kitamura 7/23/2003

Page 13: PMT High Voltage Power Supply Status - user-web.icecube

MONS, BELGIUM OCTOBER 2003 NOBUYOSHI KITAMURA UW-MADISON / SSEC

Thoughts at the End of July, 2003

Select and pursue “Old Iseg”-style design

Need further tests

Must improve communication with vendor

Must examine design details

Conduct Failure Modes and Effects Analysis (FMEA)

Page 14: PMT High Voltage Power Supply Status - user-web.icecube

MONS, BELGIUM OCTOBER 2003 NOBUYOSHI KITAMURA UW-MADISON / SSEC

Layout Examination

http://www.ssec.wisc.edu/~kitamura/HVstatus090803/Iseg_photos2.pdf

Page 15: PMT High Voltage Power Supply Status - user-web.icecube

MONS, BELGIUM OCTOBER 2003 NOBUYOSHI KITAMURA UW-MADISON / SSEC

Failure of an Old Iseg Board

Page 16: PMT High Voltage Power Supply Status - user-web.icecube

MONS, BELGIUM OCTOBER 2003 NOBUYOSHI KITAMURA UW-MADISON / SSEC

Recommended Action

... drop Iseg as our primary candidate of the PMT HV Base board supplier and bring the alternative vendor to our focus.

--NK’s report dated September 8, 2003http://www.ssec.wisc.edu/~kitamura/reports/HVstrategy.pdf

Page 17: PMT High Voltage Power Supply Status - user-web.icecube

MONS, BELGIUM OCTOBER 2003 NOBUYOSHI KITAMURA UW-MADISON / SSEC

EMCO High Voltage Corporation

Located in Sutter Creek, California, USA

In HV business for 30+ years

Has delivered twenty (20) each of HV Generator and PMT Base Board

The prototypes performed as specified in all tested parameters

Trip report by NK:http://www.ssec.wisc.edu/~kitamura/reports/EMCO_trip_rpt.pdf

Trip report by George Anderson:http://www.ssec.wisc.edu/~kitamura/reports/Emco%20Meeting%20Report%209.19.03.pdf

Page 18: PMT High Voltage Power Supply Status - user-web.icecube

MONS, BELGIUM OCTOBER 2003 NOBUYOSHI KITAMURA UW-MADISON / SSEC

Buying 5000+

Bidding process is necessary

In process:Define / refine specifications

Page 19: PMT High Voltage Power Supply Status - user-web.icecube

MONS, BELGIUM OCTOBER 2003 NOBUYOSHI KITAMURA UW-MADISON / SSEC

Requirements & Specifications

PMT Modular HV Power Supply ERDHV Control Board Specification Control DrawingPMT HV Base Board Specification Control DrawingHV Generator Source-Controlled Drawing

Page 20: PMT High Voltage Power Supply Status - user-web.icecube

MONS, BELGIUM OCTOBER 2003 NOBUYOSHI KITAMURA UW-MADISON / SSEC

Requirements Documents

PMT High Voltage Board Requirements Document

(9000-0039*)

PMT High Voltage Power Supply Requirements

Document (9000-0039-01*)

PMT Modular High Voltage Power Supply

Requirements Document (9000-0039-02*)

“Passive Base”

*George Anderson has been maintaining these documents.

Page 21: PMT High Voltage Power Supply Status - user-web.icecube

MONS, BELGIUM OCTOBER 2003 NOBUYOSHI KITAMURA UW-MADISON / SSEC

Improved Specifications

PMT Base BoardNew pulse-coupling transformer designThrough-hole componentsAdditional RC filter at HV entryImproved output cable attachment

HV Generator“HV_DISABLE” pin is addedModified MON and PROG analog rangeHigher-voltage-rated output cableEliminate GAIN_ADJ trim-pot

HV Control BoardHigher reliability due to fewer components

(delete three ICs)http://www.ssec.wisc.edu/~kitamura/HVReview_091603.htm

Page 22: PMT High Voltage Power Supply Status - user-web.icecube

MONS, BELGIUM OCTOBER 2003 NOBUYOSHI KITAMURA UW-MADISON / SSEC

PMT Base Board

Page 23: PMT High Voltage Power Supply Status - user-web.icecube

MONS, BELGIUM OCTOBER 2003 NOBUYOSHI KITAMURA UW-MADISON / SSEC

Toroidal Transformer

PP’

S

S’

S

S’

P

P’

Old TransformerRG178 coaxial cable

Rated at 1000Vrms

New Transformer22 AWG silicone-insulated bifilar

Rated at 10kV

Page 24: PMT High Voltage Power Supply Status - user-web.icecube

MONS, BELGIUM OCTOBER 2003 NOBUYOSHI KITAMURA UW-MADISON / SSEC

Toroidal Transformer Response

Temperature = −40oCPMT gain = ~1 x 107

New

Old

nsec

The bifilar transformer performs better!

Each curve is an average over 1000 triggers.

Laboratory HV supply with an EMCO passive base was used.

http://www.ssec.wisc.edu/~kitamura/toroid.htm

Page 25: PMT High Voltage Power Supply Status - user-web.icecube

MONS, BELGIUM OCTOBER 2003 NOBUYOSHI KITAMURA UW-MADISON / SSEC

Output Cable Attachment

Proposed

Iseg

EMCO

Page 26: PMT High Voltage Power Supply Status - user-web.icecube

MONS, BELGIUM OCTOBER 2003 NOBUYOSHI KITAMURA UW-MADISON / SSEC

HV Generator

Spec changes:

Change PROG range from 0..4095V to 0..2047V

Change MON range from 0..4095V to 0..2047V

Add “HV_DISABLE” pin (No reliability penalty. Optional usage)

Eliminate GAIN_ADJ trim-pot (No need for absolute accuracy)

Use higher-voltage-rated output cable

Overall simplicity and increased reliability

Page 27: PMT High Voltage Power Supply Status - user-web.icecube

MONS, BELGIUM OCTOBER 2003 NOBUYOSHI KITAMURA UW-MADISON / SSEC

HV Control Board

Spec changes:

Change PROG range from 0..4095V to 0..2047VEliminates x 2 OP-AMPEliminates –5V power switch

Change MON range from 0..4095V to 0..2047VEliminate 0..4096V REF

Overall simplicity and increased reliability

Page 28: PMT High Voltage Power Supply Status - user-web.icecube

MONS, BELGIUM OCTOBER 2003 NOBUYOSHI KITAMURA UW-MADISON / SSEC

Tasks Ahead

Test Rev 3 Main Boards with the EMCO passive base / HV generator.

Test new EMCO samples (4) with Rev 3 Main Boards

Have EMCO deliver 60 each of the PMT Base Board and the HV Control Board (including the HV Generator)

Complete specification control drawing for the bid package

Create verification plan

Page 29: PMT High Voltage Power Supply Status - user-web.icecube

MONS, BELGIUM OCTOBER 2003 NOBUYOSHI KITAMURA UW-MADISON / SSEC

Conclusion

Just as System concluded after the recent PDR, mature in design but weak in verification.