8
Portable Emissions Measurement System (PEMS) for nanoparticle counting and classification. testo NanoMet3

Portable Emissions Measurement System (PEMS) for … · 2017. 6. 1. · The increasing importance of accurate and cost effective testing has become a significant issue for the industry

  • Upload
    others

  • View
    2

  • Download
    0

Embed Size (px)

Citation preview

  • Portable Emissions Measurement System (PEMS) for nanoparticle counting and classification.

    testo NanoMet3

  • The portable solid particle counter testo NanoMet3.Measure in real environmental situations.

  • Test any vehicle.Everywhere.

    Onboard measurement of real driving emissions. Easy handling: One button measurement.

  • testo NanoMet3 is a Portable Emissions Measurement

    System – PEMS to measure number concentration and

    average diameter of solid nanoparticles in the size range

    10 – 700 nm under real driving conditions.

    It is compact, easily portable, rugged design and provides

    on-line response over a wide concentration range. These

    properties make it a suitable instrument for particle

    number concentration measurements in non-laboratory

    settings and even OBD instrumentation.

    In addition to standard 100 – 240V AC power supply,

    testo NanoMet3 can be 12 – 24V DC battery operated

    for onboard and field measurements. The response time

    is short enough to measure transient engine operation,

    providing a complete data string with particle number

    concentration, average size, lung deposited surface

    area LDSA and calculated particle mass with 1Hz

    resolution. The wide measurement range (diluted 1E4

    – 3E8 pt/cm3) covers practically all exhaust emission

    standards regarding particle number including the latest

    requirements of EURO6.

    Testo believes that NanoMet3 is therefore the ideal

    candidate for in-use-compliance testing, as well as for

    future PEMS type approval.

    Particle size: 10 to 700 nm

    Raw gas particle concentration:

    1E4 to 3E8 pt/ccm

    Power supply:12-24 VDC / 100-240 VAC

    Gas conditioning:ThermoDilution PMP compliant

    Portable Emissions Measurement System – PEMSfor nanoparticle counting and classification

  • PEMS matters

    The increasing importance of accurate

    and cost effective testing has become a

    significant issue for the industry. A vast

    experience in nanoparticle measuring

    equipment for automotive, laboratory

    and ambient applications enabled us to

    develop a rugged, portable and cost-

    effective solid nanoparticle counter. The

    PEMS methodology and approach has

    been recognized by many governmental

    entities such as the U.S. Environmental

    Protection Agency – USEPA and the United

    Nations Framework Convention on Climate

    Change – UNFCCC. Particle counting on

    diesel light-duty vehicles is mandatory in

    Europe for type approval through Euro 5b

    since September 2011 and has been also

    introduced for GDI technology through Euro

    6 by September 2014. The European Union

    and other countries worldwide will continue

    to integrate particle counting into their

    emission standards, especially since the

    World Health Organization reclassified diesel

    engine exhaust as ‘carcinogenic to humans’.

    Moreover, the European Commission is

    working on the approach for the technical

    assessment of PEMS for particle number

    emitted by light-duty vehicles. The oncoming

    test procedure for EURO 6c standards

    may include on-road measurements as an

    extension of the PMP. Portable Emission

    Measurement Systems (PEMS) have been

    proven for certain applications to better

    identify in-use performance of vehicles than

    standard laboratory measurements. They

    are designed to measure emissions during

    the actual use of an internal combustion

    engine vehicle or equipment in its regular

    daily operation under real-world conditions.

    Furthermore PEMS constitute a cost effective

    solution to perform in-service testing of

    heavy-duty engines: rather than extracting

    the engines from the vehicles and then

    installing them on an engine dynamometer

    to run their official regulatory cycles, the

    vehicles are equipped with on-board

    emission measurement systems and tested

    during their real in-use operation.

    Measurement principle

    When the sampling point of the PEMS during

    Real Driving Emissions is at the outlet of

    the tailpipe, the volatile substances may

    condense into nanodroplets, which can be

    detected as particles together with non-

    volatile solid particles. To measure only

    the solid particle fraction, it is necessary to

    condition the sample thermally to remove

    the volatile fraction. NanoMet3 features

    a separate sample at the source and

    conditioning of the exhaust probe according

    to Testo patented Thermo-Dilution principle,

    which is fully PMP compliant.

    The portable system is completed with

    Testo proprietary Diffusion Size Classifier

    technology, a new sensor for measuring the

    number concentration and average diameter

    of nanometer sized particles. Since its

    measuring principle uses electrical charging

    to count particles, it not only enhances the

    quality of the global measurement, but also

    the cost of acquisition and costs per test are

    significantly lower. Hydrocarbon emission

    measurement will no longer be affected by

    butanol contamination in the testing room,

    nor will it be influenced by contaminated air.

  • Raw data can be stored in internal HD, exported by SD-card or directly read by a host computer.

    aerosol primarily diluted exhaust gases or air which contains nanoparticles

    concentration range sensor: 1E3 to 1E6 pt/ccm; diluted: 1E4 to 3E8pt/ccm

    particle size 10 to 700 nm = 0.01 to 0.70 μmaverage particle size range (mode diameter)

    10 to 300 nm = 0.01 to 0.30 μm

    inlet gas flow 4.0 lN/min, actively fed to the diluter by internal pump

    dilution factor standard: 10, 100, 300. Optional one custom DF.

    measuring gas 1.0 lN/min measuring gaspower supply 12-24 VDC, max. 60A. 90-240 VAC 50/60 Hzpower consumption nominal 650W; 300 W under standard ambient

    conditionsevaporation tube temperatures

    ambient to 300 °C / 572 °F; accuracy ±3 °C / 5,4 °F

    assembly 19" case with handlesweight approx. 18 kg;

    with complete connections: ca. 23 kgoperating conditions Tamb: 5 to 35 °C; 0 to 80%RH, max. 80%@30

    °C, linearly degrading to 50%@35 °C, non-condensing

    sensor calibration standard calibration with NaCl particlessystem calibration against PMP-System with soot from

    CAST @ GMD 60 nm and 85 nm

    testo NanoMet3 assists you from engine development to vehicle certification.

    testo NanoMet3 provides easy and cost-effective access to valuable data such as:

    • Particlenumberconcentration[pt/cm³]

    • Averageparticlediameter[nm]

    • Calculatedparticlemass[mg/m³]

    • Lungdepositionsurfacearea(µm²/cm³)

    Communication

    • Easyrecordingon«Secure

    Digital Memorycard»

    • 2USBports

    • RS232port

    • AOport

    • LAN/Ethernetport

    • WLAN(Optional)

    • AKProtocol

    • INCACommunication

    For more detailed information call

    +49 (0)7653 681 5062

    [email protected]

    Technical Specifications

  • Order No. Description

    444 testo NanoMet3 - Portable solid nanoparticle coun-ter (PEMS PNC) Incl. transport case, heated line, LAN cable, antenna wire-less, SD-card, USB extension cable, external signal cable, battery cable, D-Sub socket and D-Sub plug, waste-gas hose with coupling socket, country specific power cord and calibration sheet

    Please select the country specific power cord:

    78021 Power cord 2 m, 3 x 1 mm2 CH-plug

    78022 IEC power 2.5 m 3 x 1 mm2, Schuko plug

    78023 Power cord 2 m, 3 x 1 mm2 US-plug

    78024 Power cord 2.5 m, 3 x 1 mm2 GB-plug

    78025 Power cord, 3 x 1 mm2 AU-plug

    2444 Yearly Service Pack (including calibration) for NanoMet3

    2446 Calibration NanoMet3

    Order No. Description

    Accessories and spare parts NanoMet3

    333 NanoMet3 Sensor

    N3001 Transport case

    N1602 Heated sampling line6424 Battery cables (power supply)

    N4303 Antenna wireless 2,4 GHz

    6425 External signal cable for analog output

    Set excess-gas output

    68010 Silicon hose

    N3509 Coupling socket

    Set OBD adapter

    4445 OBD-BT-Adapter Scantool

    4446 USB-BT-Adapter for OBD Communication

    4447 Navilock GPS

    4448 INCA Connection (Hardware and Software)

    Spare 3-pin power cord

    78021 Power cord 2 m, 3 x 1 mm2 CH-plug

    78022 IEC power 2.5 m 3 x 1 mm2, Schuko plug

    78023 Power cord 2 m, 3 x 1 mm2 US-plug

    78024 Power cord 2.5 m, 3 x 1 mm2 GB-plug

    78025 Power cord, 3 x 1 mm2 AU-plug

    testo NanoMet3 vs PMP

    NEDC PMP-Benchmark NanoMet3

    Partic

    leC

    ounts[#/s]

    Time[s]

    |200

    |400

    |600

    |800

    |1000

    |1200

    3.0E+11 —

    — 120

    — 140

    2.5E+11 —

    — 100

    1.0E+11 —— 40

    2.0E+11 —

    — 80

    0.5E+11 — — 20

    1.5E+11 —

    — 60

    0 — — 0

    VehicleSpee

    d[k

    m/h]

    testo NanoMet3, DF=300

    ECE: PNavg:2E+12#/km, avg: 115 nm EUDC: PN avg:1,1E+12#/km, avg: 95 nm

    Benchmark, DF=300

    (20x15)ECE: PNavg:1,9E+12#/km EUDC: PNvg:1,2E+12#/km

    testoNan

    oMet3PN[#/km]

    BenchmarkPN[#/km]

    Correlation Particle Count testo NanoMet3 vs PMP-Benchmark

    y =

    1.1

    2x -

    2E

    +10

    R2

    = 0

    .99

    |0.0E+00

    |1.0E+12

    |3.0E+12

    |5.0E+12

    |2.0E+12

    |4.0E+12

    |6.0E+12

    0.0E+00 —

    1.0E+12 —

    4.0E+12 —

    2.0E+12 —

    5.0E+12 —

    3.0E+12 —

    6.0E+12 —

    Main features

    • Particlenumberconcentrationandaverage

    particle size plots versus time, total counts

    provided by software interface

    • PMPcompliantVPR(sampling&conditioning)

    • Fastresponsetorapidchangesinaerosol

    concentration

    • Butanol-freeoperation

    • EmbeddedPCandpre-installedsoftware

    • Built-indataloggingandstoragecapabilitywith

    removable memory card or internal hard disk

    • Quickchangesensorcartridge

    • Rotatingdiskwitheasymaintenance

    • Long-lifediskcoating

    • Lowmaintenance,1000operationhoursof

    diluter between recommended service

    Benchmark measurements on NEDC cycles show 90-99% correlation* between NM3 and PMP systems.*(under regular conditions)

    Ordering information

  • dk/

    I/07

    .201

    5S

    ubje

    ct t

    o ch

    ange

    , inc

    lud

    ing

    tech

    nica

    l cha

    nges

    , with

    out

    notic

    e.

    Testo AG Tel. +49 (0)7653 681 5062

    [email protected]

    www.testo-particle.com

    Your partner in nanoparticle management

    Our former specialist in nanoparticle management Matter

    Aerosol has been a member of the Testo family since 2010.

    In 2015 it has been fully integrated into the Testo AG.

    With the full integration of the nanoparticle measurement

    technology business sector, Testo AG is pursuing the

    objective of a targeted and customer-oriented utilization of

    thesynergiesinResearch&Development,aswellasthe

    extensive and proven possibilities and means available in

    industrial production, service and sales.

    Theextensive,specializedandrecognizedResearch&

    Development know-how of Matter Aerosol is now completed

    with more than 50 years’ expertise from Testo AG as a world

    market leader in the field of professional measurement

    technology. With this new arrangement, perfect solutions

    in the nanoparticle measurement technology sector will be

    developed for you.

    Subsidiaries

    Distributors

    Get in contact with our specialists.

    Send an Email to

    [email protected]

    hteStempel