PRACTICAL 2 – Constant Head Permeability Test

Embed Size (px)

Citation preview

  • 8/2/2019 PRACTICAL 2 Constant Head Permeability Test

    1/2

    PRACTICAL 2 Constant Head Permeability Test

    2.

    Permeability

    ( )

    3.

    Viscosity

    The average temperature was 24.27C, rounding up to 24.5C and using table 5

    shows as 0.8995

  • 8/2/2019 PRACTICAL 2 Constant Head Permeability Test

    2/2

    4.

    Dry Density (g/cm^3)

    5.

    Sieve Analysis Permeability = 0.576e-3

    Constant Head Permeability = 94.4e-3

    In the sieve practical the material was poorly graded uniform sand (SP), which

    would have a high permeability as sand contains that structural property. In the

    example of Constant head the material was compacted and put through a

    vacuum to expel air. This compacting would lower the permeability, as there is

    less space to pass through.

    6.

    Some applications of the coefficient of permeability would be for dams where

    factors such as water seepage could hinder the structural integrity. Thecoefficient can be used to calculate retaining walls and can even be used to help

    with slope stability.