Upload
douglas25055
View
222
Download
0
Embed Size (px)
8/14/2019 Prcticas Visuales Lab. Maq. Elc. (Parte 3)
1/14
0
30V
150V
TRANSFORMER- A
TRANSFORMER- B
TRANSFORMER- CH1
X1
H5H4H3H2
X2 X3 X4 X5 X6 X7
H1 H5H4H3H2 H1 H5H4H3H2
X1 X2 X3 X4 X5 X6 X7 X1 X2 X3 X4 X5 X6 X7
L
OAD
HAMPDEN ENGINEERING CORP Hampden EAST LONGMEDOW.MASS
L
INE
0
300V
STOP
120V 208V3
Practica3
c) Conexiones de los trafo Monofasicos encircuitos trifsicosC10) Y- punto medio conectado a tierra
8/14/2019 Prcticas Visuales Lab. Maq. Elc. (Parte 3)
2/14
8/14/2019 Prcticas Visuales Lab. Maq. Elc. (Parte 3)
3/14
Practica4
3 a 6 doble
0
30V
150V
TRANSFORMER- A
TRANSFORMER- B
TRANSFORMER- CH1
X1
H5H4H3H2
X2 X3 X4 X5 X6 X7
H1 H5H4H3H2 H1 H5H4H3H2
X1 X2 X3 X4 X5 X6 X7 X1 X2 X3 X4 X5 X6 X7
L
OAD
HAMPDEN ENGINEERING CORP Hampden EAST LONGMEDOW.MASS
L
INE
0
300V
STOP
120V 208V3
1) Transformacin defases:
8/14/2019 Prcticas Visuales Lab. Maq. Elc. (Parte 3)
4/14
3 a 6 doble Y
0
30V
150V
TRANSFORMER- A
TRANSFORMER- B
TRANSFORMER- CH1
X1
H5H4H3H2
X2 X3 X4 X5 X6 X7
H1 H5H4H3H2 H1 H5H4H3H2
X1 X2 X3 X4 X5 X6 X7 X1 X2 X3 X4 X5 X6 X7
L
OAD
HAMPDEN ENGINEERING CORP Hampden EAST LONGMEDOW.MASS
L
INE
0
300V
STOP
120V 208V3
Practica4
1) Transformacin defases:
8/14/2019 Prcticas Visuales Lab. Maq. Elc. (Parte 3)
5/14
Practica4
3 a 6
diametral
0
30V
150V
TRANSFORMER- A
TRANSFORMER- B
TRANSFORMER- CH1
X1
H5H4H3H2
X2 X3 X4 X5 X6 X7
H1 H5H4H3H2 H1 H5H4H3H2
X1 X2 X3 X4 X5 X6 X7 X1 X2 X3 X4 X5 X6 X7
L
OAD
HAMPDEN ENGINEERING CORP Hampden EAST LONGMEDOW.MASS
L
INE
0
300V
STOP
120V 208V3
1) Transformacin defases:
8/14/2019 Prcticas Visuales Lab. Maq. Elc. (Parte 3)
6/14
Practica4
2) Auttrafo
0
30V
150V
TRANSFORMER- A
TRANSFORMER- B
TRANSFORMER- CH1
X1
H5H4H3H2
X2 X3 X4 X5 X6 X7
H1 H5H4H3H2 H1 H5H4H3H2
X1 X2 X3 X4 X5 X6 X7 X1 X2 X3 X4 X5 X6 X7
L
OAD
HAMPDEN ENGINEERING CORP Hampden EAST LONGMEDOW.MASS
L
INE
0
300V
STOP
120V 208V3
V
Auttrafoelevador
8/14/2019 Prcticas Visuales Lab. Maq. Elc. (Parte 3)
7/14
Practica4
Auttrofo 3 elevador Y
0
30V
150V
TRANSFORMER- A
TRANSFORMER- B
TRANSFORMER- CH1
X1
H5H4H3H2
X2 X3 X4 X5 X6 X7
H1 H5H4H3H2 H1 H5H4H3H2
X1 X2 X3 X4 X5 X6 X7 X1 X2 X3 X4 X5 X6 X7
L
OAD
HAMPDEN ENGINEERING CORP Hampden EAST LONGMEDOW.MASS
L
INE
0
300V
STOP
120V 208V3
2) Auttrafo
8/14/2019 Prcticas Visuales Lab. Maq. Elc. (Parte 3)
8/14
PRACTICA # 5
1. Determinar la relacin entre la direccin de rotacin y la direccindel flujo de campo con la polaridad del voltaje de salida de ungenerador cc
2. Estudiar la relacin entre el voltaje de vacio y la corriente de campoen un generador separadamente excitado. (Curva de saturacin deun generador separadamente excitado)
3. Obtener las caractersticas interna y externa de un generador de c.c
GENERADOR DE CORRIENTECONTINUA
OBJETIVO
8/14/2019 Prcticas Visuales Lab. Maq. Elc. (Parte 3)
9/14
AC STARTERLOAD
0-208/120V-3-13
LINE
L1
UNIV MACHFIELD RHEO
1 IND MOTORLOAD
LINE
FIXED 208/120V-3
UNIV MACH
RESISTENCE LOAD115-1-3w
RESISTENCE LOAD115-3-3w
L1 L2
115-2-3w-15A
WOUND ROTORRHEOSTAT
DINA FILDRHEO
2A
DC STARTERLOAD
+ -
LINE
FIELD
3 SYNMOTOR
110-DC-30A+ -
INPUT DC SORCE
VARFIXED
DINAM
+
-
ELC
EQ
1
1 J3 X2
X4
A
VOLTAJETACOMETRO
120 AC
J2
2 3 4 5 6 7 8 9 10 11 12 J1
2 3 4 5 6 7 8 9 10 11 12
ESTATOR
UNIVERSAL LAB MACHINEMODELO 120
A
B
B1B2
C
A2
Q1
Q2
D1D2
ROTOR X1
X5
X3
X6
DIN ROTOR
ESTATOR
ROTOR
SEARCH COILS
XX AA
X
DINAM
LOW HIGHT
V
Practica5Direccin de
rotacin
8/14/2019 Prcticas Visuales Lab. Maq. Elc. (Parte 3)
10/14
AC STARTERLOAD
0-208/120V-3-13
LINE
L1
UNIV MACHFIELD RHEO
1 IND MOTORLOAD
LINE
FIXED 208/120V-3
UNIV MACH
RESISTENCE LOAD115-1-3w
RESISTENCE LOAD115-3-3w
L1 L2
115-2-3w-15A
WOUND ROTORRHEOSTAT
DINA FILDRHEO
2A
DC STARTERLOAD
+ -
LINE
FIELD
3 SYNMOTOR
110-DC-30A+ -
INPUT DC SORCE
VARFIXED
DINAM
+
-
ELC
EQ
1
1 J3 X2
X4
A
VOLTAJETACOMETRO
120 AC
J2
2 3 4 5 6 7 8 9 10 11 12 J1
2 3 4 5 6 7 8 9 10 11 12
ESTATOR
UNIVERSAL LAB MACHINEMODELO 120
A
B
B1B2
C
A2
Q1
Q2
D1D2
ROTOR X1
X5
X3
X6
DIN ROTOR
ESTATOR
ROTOR
SEARCH COILS
XX AA
X
DINAM
LOW HIGHT
curva desaturacin
Plug10
A
2 Down
Practica5
8/14/2019 Prcticas Visuales Lab. Maq. Elc. (Parte 3)
11/14
AC STARTERLOAD
0-208/120V-3-13
LINE
L1
UNIV MACHFIELD RHEO
1 IND MOTORLOAD
LINE
FIXED 208/120V-3
UNIV MACH
RESISTENCE LOAD115-1-3w
RESISTENCE LOAD115-3-3w
L1 L2
115-2-3w-15A
WOUND ROTORRHEOSTAT
DINA FILDRHEO
2A
DC STARTERLOAD
+ -
LINE
FIELD
3 SYNMOTOR
110-DC-30A+ -
INPUT DC SORCE
VARFIXED
DINAM
+
-
ELC
EQ
1
1 J3 X2
X4
A
VOLTAJETACOMETRO
120 AC
J2
2 3 4 5 6 7 8 9 10 11 12 J1
2 3 4 5 6 7 8 9 10 11 12
ESTATOR
UNIVERSAL LAB MACHINEMODELO 120
A
B
B1B2
C
A2
Q1
Q2
D1D2
ROTOR X1
X5
X3
X6
DIN ROTOR
ESTATOR
ROTOR
SEARCH COILS
XX AA
X
DINAM
LOW HIGHT
caractersticainterna y externadel generador
Plug10
A
2 Down
A
V
Practica5
8/14/2019 Prcticas Visuales Lab. Maq. Elc. (Parte 3)
12/14
AC STARTERLOAD
0-208/120V-3-13
LINE
L1
UNIV MACHFIELD RHEO
1 IND MOTORLOAD
LINE
FIXED 208/120V-3
UNIV MACH
RESISTENCE LOAD115-1-3w
RESISTENCE LOAD115-3-3w
L1 L2
115-2-3w-15A
WOUND ROTORRHEOSTAT
DINA FILDRHEO
2A
DC STARTERLOAD
+ -
LINE
FIELD
3 SYNMOTOR
110-DC-30A+ -
INPUT DC SORCE
VARFIXED
DINAM
+
-
ELC
EQ
1
1 J3 X2
X4
A
VOLTAJETACOMETRO
120 AC
J2
2 3 4 5 6 7 8 9 10 11 12 J1
2 3 4 5 6 7 8 9 10 11 12
ESTATOR
UNIVERSAL LAB MACHINEMODELO 120
A
B
B1B2
C
A2
Q1
Q2
D1D2
ROTOR X1
X5
X3
X6
DIN ROTOR
ESTATOR
ROTOR
SEARCH COILS
XX AA
X
DINAM
LOW HIGHT
curva deregulacin delgenerador serie
A V
Practica5
8/14/2019 Prcticas Visuales Lab. Maq. Elc. (Parte 3)
13/14
AC STARTERLOAD
0-208/120V-3-13
LINE
L1
UNIV MACHFIELD RHEO
1 IND MOTORLOAD
LINE
FIXED 208/120V-3
UNIV MACH
RESISTENCE LOAD115-1-3w
RESISTENCE LOAD115-3-3w
L1 L2
115-2-3w-15A
WOUND ROTORRHEOSTAT
DINA FILDRHEO
2A
DC STARTERLOAD
+ -
LINE
FIELD
3 SYNMOTOR
110-DC-30A+ -
INPUT DC SORCE
VARFIXED
DINAM
+
-
ELC
EQ
1
1 J3 X2
X4
A
VOLTAJETACOMETRO
120 AC
J2
2 3 4 5 6 7 8 9 10 11 12 J1
2 3 4 5 6 7 8 9 10 11 12
ESTATOR
UNIVERSAL LAB MACHINEMODELO 120
A
B
B1B2
C
A2
Q1
Q2
D1D2
ROTOR X1
X5
X3
X6
DIN ROTOR
ESTATOR
ROTOR
SEARCH COILS
XX AA
X
DINAM
LOW HIGHT
control de vel delmotor c.c por flujovariable
Plug10
2 Down
A
V
Practica5
8/14/2019 Prcticas Visuales Lab. Maq. Elc. (Parte 3)
14/14
Tablas
Voltaje desalida
Corrientede campo
Tabla # 1 Curva de saturacin
corriente corriente Voltaje Caida deTension Voltaje
de campo If de carga IL Terminal V en Armadura Generado E
Tabla # 2