13
PRELIMINARY SITE CALCULATIONS LOT 2 DP874088 SUTHERLAND SHIRE COUNCIL ZONE : E4 ENVIRONMENTAL LIVING SITE AREA : 510.3m² DA REQUIREMENTS MAXIMUM GROSS FLOOR AREA PERMITTED = 0.55:1 = 280.665m² EXISTING GROSS FLOOR AREA = 100.95m² = 110.88m² = 0.198:1 (EXCLUSIVE OF GARAGE) PROPOSED FIRST FLOOR GROSS FLOOR AREA = 75.56m² TOTAL GROSS FLOOR AREA : 176.51m² = 0.346:1 MINIMUM LANDSCAPE AREA = 204.12m² = 40% EXISTING LANDSCAPE AREA = 189.89m² = 37.2% MAXIMUM BUILDING HEIGHT = 8.5m RIDGE FRONT SETBACK REQUIRED = 4m (INTERNAL LOT) REAR SETBACK REQUIRED = 6m SIDE SETBACK REQUIRED = 0.9m/1.5m EXISTING FRONT SETBACK = 3.227m / 25.003m EXISTING REAR SETBACK = 5.732m EXISTING SOUTH WEST SIDE SETBACK = 4.830m EXISTING NORTH EAST SIDE SETBACK = 1.98m PROPOSED FRONT SETBACK = 4.528m / 26.304m PROPOSED REAR SETBACK = 10.378m PROPOSED SOUTH WEST SIDE SETBACK = 4.995m PROPOSED NORTH EAST SIDE SETBACK - 6.07m ENVIRONMENTAL SENSITIVITY - N/A HERITAGE = N/A ARCHAEOLOGICAL SENSITIVITY = MEDIUM ACID SULFATE SOILS = CLASS 5 FLOOD PRONE AREA = N/A BUSH FIRE AREA = N/A LANDSCAPE CALCULATIONS : NOT COMPLIANT WITH DA REQUIREMENTS - SHORTFALL OF 14.23m² = 2.8% ISSUED FOR DEVELOPMENT APPLICATION NOT FOR CONSTRUCTION EXISTING SETBACK 4810 12:00 15:00 09:00 EX. RESIDENCE 10A KOEL PLACE SINGLE STOREY REQUIRED SETBACK 1500 REQUIRED SE TBACK 6 000 REQUIRED SETBACK 1500 EXISTING SETBACK 1975 BOUNDARY 25 .085 m BOUNDARY 20.520 m BOUNDARY 24 .705 m 6 0% S I TE DEPTH PROPOSED FIRST FLOOR ADDITION 150 VC - APPR OX 1. 2M DEEP 150 VC - APPR OX 1.2M D EEP M AI N T EN ANCE HOLE PROPOSED FRONT SET BAC K 4 528 PROPOSED R EAR SETBACK 1 0382 PROPOSED SIDE SETBACK 4995 PROPOSED SIDE SETBACK 6070 EXIS TIN G F RONT SE T BACK 3 420 CONNECT TO EXISTING ON SITE STORMWATER SYSTEM EXIS TIN G RE AR SETBACK 6 000 E A S E ME NT 1 .25 m WID E EASEMENT DA RE QUI RED FRONT SET BACK 4 000 BOU NDARY 20.50 8 m R IGHT OF CAR R IAGEWAY AN D EASEMEN T FO R SER VICES 6 0 % S ITE DEPTH DESCRIPTION DATE ADDRESS CLIENT DRAWN DATE SCALE STATUS DESCRIPTION ISSUE DRAWING REVISION NOTES: - ALL DIMENSIONS ARE TO BE VERIFIED ON SITE BY THE BUILDER BEFORE COMMENCING WORK - ALL WORKS MUST COMPLY WITH RELEVANT AUSTRALIAN BUILDING CODES AND AUSTRALIAN STANDARDS - FINISHED FLOOR LEVEL REFERS TO INTERNAL FINISHED CONCRETE LEVEL - WRITTEN DIMENSIONS TAKE PRECEDENCE TO SCALE THIS DRAWING IS COPYRIGHT AND THE PROPERTY OF ROOMARK PTY LTD AND MUST NOT BE RETAINED, USED OR COPIED FOR ANY PROJECT WITHOUT WRITTEN AUTHORITY FROM ROSSMARK PTY LTD ROSSMARK PTY LTD LIC 114562C 11 ERSKINE ROAD CARINGBAH NSW 2229 T: 02 9525 5588 F: 02 9525 0111 E: [email protected] @ A3 As indicated ISSUED FOR DEVELOPMENT APPLICATION DA-01 PROPOSED FIRST FLOOR ADDITION 10A KOEL PLACE WORONORA HEIGHT NSW 2233 MR. & MRS. FARRELL JS PROPOSED FIRST FLOOR ADDITION SITE PLAN & SITE CALCULATION PLAN 0 10 2 4 SCALE 1:200 NORTH A ISSUED FOR DEVELOPMENT APPLICATION 22.11.21 A 22.11.21

PRELIMINARY SITE CALCULATIONS

  • Upload
    others

  • View
    2

  • Download
    0

Embed Size (px)

Citation preview

Page 1: PRELIMINARY SITE CALCULATIONS

PRELIMINARY SITE CALCULATIONS

LOT 2 DP874088SUTHERLAND SHIRE COUNCILZONE : E4 ENVIRONMENTAL LIVINGSITE AREA : 510.3m²

DA REQUIREMENTSMAXIMUM GROSS FLOOR AREA PERMITTED = 0.55:1 = 280.665m²EXISTING GROSS FLOOR AREA = 100.95m² = 110.88m² = 0.198:1 (EXCLUSIVE OF GARAGE)PROPOSED FIRST FLOOR GROSS FLOOR AREA = 75.56m²TOTAL GROSS FLOOR AREA : 176.51m² = 0.346:1

MINIMUM LANDSCAPE AREA = 204.12m² = 40%EXISTING LANDSCAPE AREA = 189.89m² = 37.2%MAXIMUM BUILDING HEIGHT = 8.5m RIDGEFRONT SETBACK REQUIRED = 4m (INTERNAL LOT)REAR SETBACK REQUIRED = 6mSIDE SETBACK REQUIRED = 0.9m/1.5m

EXISTING FRONT SETBACK = 3.227m / 25.003mEXISTING REAR SETBACK = 5.732mEXISTING SOUTH WEST SIDE SETBACK = 4.830mEXISTING NORTH EAST SIDE SETBACK = 1.98m

PROPOSED FRONT SETBACK = 4.528m / 26.304m

PROPOSED REAR SETBACK = 10.378mPROPOSED SOUTH WEST SIDE SETBACK = 4.995m

PROPOSED NORTH EAST SIDE SETBACK - 6.07m

ENVIRONMENTAL SENSITIVITY - N/AHERITAGE = N/AARCHAEOLOGICAL SENSITIVITY = MEDIUMACID SULFATE SOILS = CLASS 5 FLOOD PRONE AREA = N/ABUSH FIRE AREA = N/A

LANDSCAPE CALCULATIONS : NOT COMPLIANT WITH DA

REQUIREMENTS - SHORTFALL OF 14.23m² = 2.8%

ISSUED FOR DEVELOPMENT APPLICATION

NOT FOR CONSTRUCTION

EXIS

TIN

G S

ETBA

CK

4810

12:00

15:0

0

09:0

0

EX. RESIDENCE

10A KOEL PLACE

SINGLE STOREY

REQ

UIRED

SET

BAC

K

1500

REQUIRED SETBACK

6 000

REQ

UIRED

SET

BAC

K

1500

EXIS

TIN

G S

ETBA

CK

1975

BOUNDARY 25.085 m

BO

UN

DA

RY 2

0.52

0 m

BOUNDARY 24.705 m

60% SITE DEPTH

PROPOSED FIRST FLOOR ADDITION

150

VC

-A

PPR

OX 1

.2M

DE

EP

150 VC - APPROX 1.2M DEEP

MAINTENANCE

HOLE

PROPOSED FRONT SETBACK

4528

PROPOSED REAR SETBACK

10382PR

OPO

SED

SIDE

SETB

ACK

4995

PRO

POSE

D SI

DE SE

TBAC

K

6070

EXISTING FRONT SETBACK

3420

CONNECT TO EXISTING ON SITE STORMWATER SYSTEM

EXISTING REAR SETBACK

6 000

EASEMENT 1.25m WIDE

EASE

MEN

T

DA REQUIRED FRONT SETBACK

4000

BO

UN

DAR

Y 2

0.50

8 m

RIGHT OF CARRIAGEWAY AND EASEMENT FOR SERVICES

60% SITE DEPTH

DESCRIPTIONDATE

ADDRESS

CLIENT

DRAWN

DATE

SCALE

STATUS

DESCRIPTIONISSUE

DRAWING REVISIONNOTES:

- ALL DIMENSIONS ARE TO BE VERIFIED ON SITE BY THE BUILDER BEFORE COMMENCING WORK

- ALL WORKS MUST COMPLY WITH RELEVANT AUSTRALIAN BUILDING CODES AND AUSTRALIAN STANDARDS

- FINISHED FLOOR LEVEL REFERS TO INTERNAL FINISHED CONCRETE LEVEL

- WRITTEN DIMENSIONS TAKE PRECEDENCE TO SCALE

THIS DRAWING IS COPYRIGHT AND THE PROPERTY OF ROOMARK PTY LTD AND MUST NOT BE RETAINED,

USED OR COPIED FOR ANY PROJECT WITHOUT WRITTEN AUTHORITY FROM ROSSMARK PTY LTD

ROSSMARK PTY LTD LIC 114562C

11 ERSKINE ROAD CARINGBAH NSW 2229

T: 02 9525 5588 F: 02 9525 0111 E: [email protected]

@ A3As indicated

ISSUED FOR DEVELOPMENT APPLICATION

DA-01

PROPOSED FIRST FLOOR ADDITION

10A KOEL PLACE WORONORA HEIGHT NSW 2233

MR. & MRS. FARRELLJS

PROPOSED FIRST FLOOR ADDITION

SITE PLAN & SITE CALCULATION PLAN

0 102 4

SCALE 1:200

NORTH

A ISSUED FOR DEVELOPMENT APPLICATION 22.11.21

A22.11.21

Page 2: PRELIMINARY SITE CALCULATIONS

ISSUED FOR DEVELOPMENT APPLICATION

NOT FOR CONSTRUCTION

EX. RESIDENCE

10A KOEL PLACESINGLE STOREY

BOUNDARY 25.085 m

BO

UN

DA

RY 2

0.52

0 m

BOUNDARY 24.705 m

PROPOSED FIRST FLOOR ADDITION

150

VC

-A

PPR

OX 1

.2M

DE

EP

150 VC - APPROX 1.2M DEEP

MAINTENANCE

HOLE

CONNECT TO EXISTING ON SITE STORMWATER SYSTEM

EASEMENT 1.25m WIDE

EASE

MEN

TSILT AND SEDIMENT CONTROL BARRIER

WASTE BIN

MA

TER

IAL

STO

RA

GE

& S

ITE

SIG

N IN

AR

EA

SIT

E

AC

CE

SS

P

OIN

T

SITE SIGNAGE AND IDENTIFICATION SCREEN

TO DRIVEWAY ENTRANCE - LOCKABLE

DESCRIPTIONDATE

ADDRESS

CLIENT

DRAWN

DATE

SCALE

STATUS

DESCRIPTIONISSUE

DRAWING REVISIONNOTES:

- ALL DIMENSIONS ARE TO BE VERIFIED ON SITE BY THE BUILDER BEFORE COMMENCING WORK

- ALL WORKS MUST COMPLY WITH RELEVANT AUSTRALIAN BUILDING CODES AND AUSTRALIAN STANDARDS

- FINISHED FLOOR LEVEL REFERS TO INTERNAL FINISHED CONCRETE LEVEL

- WRITTEN DIMENSIONS TAKE PRECEDENCE TO SCALE

THIS DRAWING IS COPYRIGHT AND THE PROPERTY OF ROOMARK PTY LTD AND MUST NOT BE RETAINED,

USED OR COPIED FOR ANY PROJECT WITHOUT WRITTEN AUTHORITY FROM ROSSMARK PTY LTD

ROSSMARK PTY LTD LIC 114562C

11 ERSKINE ROAD CARINGBAH NSW 2229

T: 02 9525 5588 F: 02 9525 0111 E: [email protected]

@ A3As indicated

ISSUED FOR DEVELOPMENT APPLICATION

DA-02

PROPOSED FIRST FLOOR ADDITION

10A KOEL PLACE WORONORA HEIGHT NSW 2233

MR. & MRS. FARRELLJS

PROPOSED FIRST FLOOR ADDITION

PROPOSED SITE MANAGEMENT PLAN

0 102 4

SCALE 1:200

NORTH

A ISSUED FOR DEVELOPMENT APPLICATION 22.11.21

A22.11.21

Page 3: PRELIMINARY SITE CALCULATIONS

123° 00' 24.705

303° 00' 25.085

31°

40' 1

0" 2

0.505

210°

35' 5

0" 2

0.52

99m

RIGHT OF CARRIAGEWAY & EASEMENT FOR SERVICES (VARIABLE W

IDTH)

EASEMENT TO DRAIN WATER (1.25 WIDE)

EA

SE

ME

NT T

O D

RAIN

WA

TE

R (1 W

IDE

)

A

B

A-EASEMENT TO DRAIN W

ATER (3.1 WIDE)

B-EASEMENT TO DRAIN W

ATER (1.25 WIDE)

98.5m

98.5m

98m

97.5m

97m

97m

99m

H99.02

TG102.91

RIDGE RL 104.79

TG103.07

TG100.45

TG99.85

TG99.86

TG99.86

RIDGE RL 101.20

TG99.23

TG99.14

S100.84

H102.95

S101.87

H102.95

H102.95

H102.95

H102.95

H102.95

H99.02

KO

EL

PLA

CE

SITE DETAIL & LEVELS PLAN

LOT 2 IN DP 874088

TW98.54

TW98.53

TW98.62

TW97.95

TW97.44

TW96.73

TW96.64

TW96.68

TW96.88

TW97.99 TW97.98

TW98.49

TW99.18

TW98.59

TW98.82

THE TITLE BOUNDARIES SHOWN HEREON HAVE BEEN LOCATED

BY

IS FOR ILLUSTRATIVE PURPOSES AND IS NOT TO BE MEASURED WITHIN

THE

THE DATA CONTAINED IN THIS CAD DRAWING AND FILE HAS BEEN

OBTAINED

BY STANDARD TECHNIQUES FOR DETAIL AND TOPOGRAPHIC SURVEYS. THE

DATA

FUTURE UNDERGROUND SERVICES AND DETAILED LOCATIONS OF ALL

SERVICES.

RELEVANT AUTHORITY SHOULD BE CONTACTED FOR POSSIBLE LOCATION

OF

PRIOR TO ANY DEMOLITION, EXCAVATION OR CONSTRUCTION ON SITE

THE

THE LEVEL DATUM OF THE SURVEY IS A.H.D. WITH THE ORIGIN OF

LEVELS

SERVICES SHOWN HEREON HAVE BEEN LOCATED BY FIELD SURVEY

ONLY.

1.

3.

4.

5.

MODEL FOR STRUCTURAL PURPOSES OR CRITICAL DESIGN.

BEING SSM 46154 WITH A VALUE OF 107.8

(AHD).

PLAN DIMENSIONS ONLY FROM D.P.

874088

CONTOURS ARE AN INDICATION OF THE TOPOGRAPHY AND SHOULD ONLY

BEUSED FOR PLANNING PURPOSES. IF DETAILED DESIGN IS TO BE UNDERTAKEN,

SPOT LEVELS SHOULD BE

USED.

6.

THE RELATIONSHIP OF IMPROVEMENTS AND DETAIL TO

BOUNDARIES

WHERE NOT SHOWN IS DIAGRAMMATIC AND IF CRITICAL SHOULD

BE

2.CONFIRMED BY A FURTHER BOUNDARY

SURVEY.

TOP OF

BM CUT IN KERB

RL 101.40(AHD)

DP874088

LOT 1

12S0.5∅

TREE

WALL-BDY

(2.005)

DP776268

LOT 388

DP776268

LOT 396

DP776268

LOT 386

6S0.2∅

TREE

12S0.5∅

TREE

12S0.5∅

TREE

SHED

METAL

GRATEGRATE

GRATE

DRIVEWAY

PAVED

BRICK DWELLING

SINGLE STOREY

No. 10

BRICK DWELLING

SINGLE STOREY

No. 12

BALCONY

(1.975)

WALL-BDY(3.42)

WALL-BDY(3.51)

WALL-BDY

(4.81)

WALL-BDY

(4.81)

WALL-BDY

96.79

97.89

98.12

98.09

98.20

96.93

96.94

97.95

99.14

99.31

98.69

98.36

98.12

98.01

97.56

97.49

97.46

99.00

96.81

99.24

98.25

98.41

97.02

96.94

97.01

97.58

97.51

97.13

97.13

97.01

97.42

97.9697.16

99.20

98.18

98.39

97.38

97.37

96.89

96.53

96.63

98.13

98.20

98.10

96.85

TH

IS P

LA

NG

RID

NO

RT

H

VID

E D

P 8

74

08

8

NOTES

ISSUED FOR DEVELOPMENT APPLICATION

NOT FOR CONSTRUCTION

EXIS

TIN

G S

ETBA

CK

4830

12:00

15:0

0

09:0

0

EX. RESIDENCE

10A KOEL PLACE

SINGLE STOREY

EASEMENT 1.25m WIDE

EASE

MEN

T

REQ

UIRED

SET

BAC

K

1500

REQUIRED SETBACK

6000

REQ

UIRED

SET

BAC

K

1500

EXIS

TIN

G S

ETBA

CK

1980

BOUNDARY 25.085 m

BO

UN

DA

RY 2

0.52

0 m

BOUNDARY 24.705 m

60% SITE DEPTH

PROPOSED FIRST FLOOR ADDITION

150

VC

-A

PPR

OX 1

.2M

DE

EP

150 VC - APPROX 1.2M DEEP

MAINTENANCE

HOLE

PROPOSED FRONT SETBACK

4528

PROPOSED REAR SETBACK

10382

PRO

POSE

D SI

DE SE

TBAC

K

4995

PRO

POSE

D SI

DE SE

TBAC

K

6070

EXISTING FRONT SETBACK

3420

CONNECT TO EXISTING ON SITE STORMWATER SYSTEM

60% SITE DEPTH

DESCRIPTIONDATE

ADDRESS

CLIENT

DRAWN

DATE

SCALE

STATUS

DESCRIPTIONISSUE

DRAWING REVISIONNOTES:

- ALL DIMENSIONS ARE TO BE VERIFIED ON SITE BY THE BUILDER BEFORE COMMENCING WORK

- ALL WORKS MUST COMPLY WITH RELEVANT AUSTRALIAN BUILDING CODES AND AUSTRALIAN STANDARDS

- FINISHED FLOOR LEVEL REFERS TO INTERNAL FINISHED CONCRETE LEVEL

- WRITTEN DIMENSIONS TAKE PRECEDENCE TO SCALE

THIS DRAWING IS COPYRIGHT AND THE PROPERTY OF ROOMARK PTY LTD AND MUST NOT BE RETAINED,

USED OR COPIED FOR ANY PROJECT WITHOUT WRITTEN AUTHORITY FROM ROSSMARK PTY LTD

ROSSMARK PTY LTD LIC 114562C

11 ERSKINE ROAD CARINGBAH NSW 2229

T: 02 9525 5588 F: 02 9525 0111 E: [email protected]

@ A3As indicated

ISSUED FOR DEVELOPMENT APPLICATION

DA-03

PROPOSED FIRST FLOOR ADDITION

10A KOEL PLACE WORONORA HEIGHT NSW 2233

MR. & MRS. FARRELLJS

PROPOSED FIRST FLOOR ADDITION

PROPOSED SITE SURVEY PLAN

0 102 4

SCALE 1:200

NORTH

A ISSUED FOR DEVELOPMENT APPLICATION 22.11.21

A22.11.21

Page 4: PRELIMINARY SITE CALCULATIONS

UP

UP

15265

240 3090 70 1205 70 2895 70 1495 70 950 70 1910 70 2820 240

2170 6015 7080

240 4193 70 1292 220

240 5535 240

450

4455

1479

7272

110

8521

7011

7070

3025

240

240

3975

240

1310

453

6472

6731

1365

6

240

3022

7029

0024

0

240

2505

7090

070

2900

240

240

1510

7018

9570

240

5007

029

0570

EXISTING

EX

IST

ING

EX

IST

ING

EX

IST

ING

LIN

EN

ROBE

ROBE

RO

BE

STORE

EX. POOLEX. DECK

EX. DECK

4173

160 STEP

140

ST

EP

HEAD CLEARANCE = 2054

140

ST

EP

70 920

6438 5937 2890

1365

6

15265

18.13sqm

EX. LIVING

18.22sqm

EX. GARAGE

3.50sqm

EX. BATH

27.93sqm

EX. KITCHEN / DINING

11.47sqm

EX. BED 2

3.56sqm

EX. ENSUITE

8.47sqm

EX. BED 3

3.16sqm

EN. LNDRY

1.39sqm

EX. WC 4.70sqm

EX. SHWR

8.35sqm

EX. BED 4

4.86sqm

EX. HALL

3.81sqm

EX. HALL

EX

IST

ING

ISSUED FOR DEVELOPMENT APPLICATION

NOT FOR CONSTRUCTION

DESCRIPTIONDATE

ADDRESS

CLIENT

DRAWN

DATE

SCALE

STATUS

DESCRIPTIONISSUE

DRAWING REVISIONNOTES:

- ALL DIMENSIONS ARE TO BE VERIFIED ON SITE BY THE BUILDER BEFORE COMMENCING WORK

- ALL WORKS MUST COMPLY WITH RELEVANT AUSTRALIAN BUILDING CODES AND AUSTRALIAN STANDARDS

- FINISHED FLOOR LEVEL REFERS TO INTERNAL FINISHED CONCRETE LEVEL

- WRITTEN DIMENSIONS TAKE PRECEDENCE TO SCALE

THIS DRAWING IS COPYRIGHT AND THE PROPERTY OF ROOMARK PTY LTD AND MUST NOT BE RETAINED,

USED OR COPIED FOR ANY PROJECT WITHOUT WRITTEN AUTHORITY FROM ROSSMARK PTY LTD

ROSSMARK PTY LTD LIC 114562C

11 ERSKINE ROAD CARINGBAH NSW 2229

T: 02 9525 5588 F: 02 9525 0111 E: [email protected]

@ A31 : 100

ISSUED FOR DEVELOPMENT APPLICATION

DA-04

PROPOSED FIRST FLOOR ADDITION

10A KOEL PLACE WORONORA HEIGHT NSW 2233

MR. & MRS. FARRELLJS

PROPOSED FIRST FLOOR ADDITION

EXISTING GROUND FLOOR PLAN 0 51 2

SCALE 1:100EXISTING TOTAL FLOOR AREA : 137.45m²

EXISTING GROSS FLOOR AREA : 100.95m²

NORTH

A ISSUED FOR DEVELOPMENT APPLICATION 22.11.21

A22.11.21

Page 5: PRELIMINARY SITE CALCULATIONS

UP

UP

15265

240 3090 70 1205 70 2895 70 1495 70 950 70 1910 70 2820 240

2170 6015 7080

240 4193 70 1292 220

240 5535 240

450

4455

1479

7272

110

8521

7011

7070

3025

240

240

3975

240

1310

453

6472

6731

1365

6

240

3022

7029

0024

0

240

2505

7090

070

2900

240

240

1510

7018

9570

240

5007

029

0570

EXISTING

EX

IST

ING

EX

IST

ING

EX

IST

ING

18.22sqm

EX. GARAGE

19.80sqm

EX. LIVING

30.07sqm

EX. KITCHEN / LIVING / DINING

8.35sqm

EX. BED 3

4.70sqm

EX. BATH

3.16sqm

EX. LNDRY

1.39sqm

EX. WC

8.47sqm

EX. BED 23.56sqm

EX. ENSUITE11.47sqm

EX. BED 1

LIN

EN

ROBE

ROBE

RO

BE

STORE

EX. POOLEX. DECK

EX. DECK

4173

160 STEP

140

ST

EP

HEAD CLEARANCE = 2054

140

ST

EP

70 920

6438 5937 2890

1365

615265

EX

IST

ING

ENLARGE LIVING, DELETE WALLS TO ACCOMMODATE NEW STAIRS TO PROPOSED FIRST FLOOR. INSTALL NEW

FLOORING AND MAKE GOOD

DELETE OPENING AND MAKE GOOD AFFECTED AREAS -DELETE KITCHEN, TERMINATE SERVICES AND RELOCATE -

REMOVE EXISTING TILES AND INSTALL NEW ENGINEERED TIMBER FLOORING TO LIVING, HALL, KTICHEN AND DINING.

MAKE GOOD AFFECTED SURFACES WHERE WALLS ARE REMOVED

EXISTING SKYLIGHT TO BE DELETED DUE TO FIRST FLOOR PLATFORM

DELETE EXISTING OPENINGS AND INSTALL NEW STACKER DOORS AND BIFOLD WINDOW - MAKE GOOD AFFECTED SURFACES

DELETE PART OF EXISTING SKILLION ROOFS TO ACCOMMODATE NEW BALCONY OVER -MAKE GOOD AFFECTED SURFACES

REMOVE EXISTING TILING AND PREPARE SURFACE FOR NEW SELECTED ENGINEERED TIMBER FLOORING - RETAIN STEPS

DELETE EXISTING WINDOW AND INSTALL NEW HINGED DOOR AND WINDOW TO EXISTING OPENING, MAKE GOOD AFFECTED SURFACES. SUBJECT TO CLEARING OF EXISTING STEPS

DELETE EXISTING BRICK WALL BETWEEN EXISTING CONTROL JOINTS TO CREATE OPENING FOR NEW ROLLER

GARAGE DOOR

ISSUED FOR DEVELOPMENT APPLICATION

NOT FOR CONSTRUCTION

DESCRIPTIONDATE

ADDRESS

CLIENT

DRAWN

DATE

SCALE

STATUS

DESCRIPTIONISSUE

DRAWING REVISIONNOTES:

- ALL DIMENSIONS ARE TO BE VERIFIED ON SITE BY THE BUILDER BEFORE COMMENCING WORK

- ALL WORKS MUST COMPLY WITH RELEVANT AUSTRALIAN BUILDING CODES AND AUSTRALIAN STANDARDS

- FINISHED FLOOR LEVEL REFERS TO INTERNAL FINISHED CONCRETE LEVEL

- WRITTEN DIMENSIONS TAKE PRECEDENCE TO SCALE

THIS DRAWING IS COPYRIGHT AND THE PROPERTY OF ROOMARK PTY LTD AND MUST NOT BE RETAINED,

USED OR COPIED FOR ANY PROJECT WITHOUT WRITTEN AUTHORITY FROM ROSSMARK PTY LTD

ROSSMARK PTY LTD LIC 114562C

11 ERSKINE ROAD CARINGBAH NSW 2229

T: 02 9525 5588 F: 02 9525 0111 E: [email protected]

@ A31 : 100

ISSUED FOR DEVELOPMENT APPLICATION

DA-05

PROPOSED FIRST FLOOR ADDITION

10A KOEL PLACE WORONORA HEIGHT NSW 2233

MR. & MRS. FARRELLJS

PROPOSED FIRST FLOOR ADDITION

DEMOLITION PLAN 0 51 2

SCALE 1:100EXISTING TOTAL FLOOR AREA : 137.45m²

EXISTING GROSS FLOOR AREA : 100.95m²

NORTH

A ISSUED FOR DEVELOPMENT APPLICATION 22.11.21

A22.11.21

Page 6: PRELIMINARY SITE CALCULATIONS

UP

UP

17

16

15

1413121110987654

3

2

1

15265

240 3090 70 1205 70 2895 70 1495 70 950 70 1910 70 2820 240

2170 6015 7080

240 4193 70 1292 220

240 5535 240

4455

1479

7272

110

8521

7011

7070

3025

240

240

3975

240 13

10

453

6472

6731

1365

6

240

3022

7029

0024

0

240

2505

7090

070

2900

240

240

1510

7018

9570

240

5007

029

0570

EXISTING

EX

IST

ING

EX

IST

ING

EX

IST

ING

18.22sqm

EX. GARAGE

19.80sqm

EX. LIVING

30.07sqm

EX. KITCHEN / LIVING / DINING

8.35sqm

EX. BED 3

4.70sqm

EX. BATH

3.16sqm

EX. LNDRY

1.39sqm

EX. WC

8.47sqm

EX. BED 23.56sqm

EX. ENSUITE11.47sqm

EX. BED 1

LIN

EN

ROBE

ROBE

RO

BE

STORE

EX. DECK

EX. DECK

ALTER BRICK OPENINGS TO INSTALL SINGLE-CAR, 2700 GARAGE ROLLER DOOR.

4173

650

650

160 STEP

140

ST

EP

HEAD CLEARANCE = 2054

140

ST

EPCH - 2690

CH - 2385

ENLARGE LIVING, DELETE WALLS TO ACCOMMODATE NEW STAIRS TO PROPOSED FIRST FLOOR. INSTALL NEW

FLOORING AND MAKE GOOD.

DELETE OPENING AND MAKE GOOD AFFECTED AREAS.DELETE KITCHEN, TERMINATE SERVICES AND RELOCATE .

REMOVE EXISTING TILES AND INSTALL NEW ENGINEERED TIMBER FLOORING TO LIVING, HALL, KTICHEN AND DINING.

MAKE GOOD AFFECTED SURFACES WHERE WALLS ARE REMOVED

INSTALL NEW KITCHEN, ROUGH-IN SERVICES TO PROPOSED LAYOUT AND FITOUT

1000

EXISTING SKYLIGHT TO BE DELETED DUE TO FIRST FLOOR PLATFORM

F.P.

TURNING C

IRCLE O

F VEHIC

LE

9092

070 920

DELETE EXISTING OPENINGS AND INSTALL NEW STACKER DOORS AND BIFOLD WINDOW - MAKE GOOD AFFECTED SURFACES - TOOTH BRICKWORK AND PATCH

FIRST FLOOR OUTLINE

2542 70 2913 90 3210 3770

DELETE PART OF EXISTING SKILLION ROOFS TO ACCOMMODATE NEW BALCONY OVER.MAKE GOOD AFFECTED SURFACES.

FIR

EP

LA

CE

REUSE EXISTING STOVETOP

FISHER & PAYKEL

REMOVE EXISTING TILING AND PREPARE SURFACE FOR NEW SELECTED ENGINEERED TIMBER FLOORING.RETAIN STEPS

DELETE EXISTING WINDOW AND INSTALL NEW HINGED DOOR AND WINDOW TO EXISTING OPENING, MAKE GOOD AFFECTED SURFACES. SUBJECT TO CLEARING OF EXISTING STEPS. - TOOTH BRICKWORK AND PATCH

ASD 2127

W01

D01

1DA-13

1DA-13

D02

D05

W02

BiFold 1225

AA

W 1

309

ISSUED FOR DEVELOPMENT APPLICATION

NOT FOR CONSTRUCTION

DESCRIPTIONDATE

ADDRESS

CLIENT

DRAWN

DATE

SCALE

STATUS

DESCRIPTIONISSUE

DRAWING REVISIONNOTES:

- ALL DIMENSIONS ARE TO BE VERIFIED ON SITE BY THE BUILDER BEFORE COMMENCING WORK

- ALL WORKS MUST COMPLY WITH RELEVANT AUSTRALIAN BUILDING CODES AND AUSTRALIAN STANDARDS

- FINISHED FLOOR LEVEL REFERS TO INTERNAL FINISHED CONCRETE LEVEL

- WRITTEN DIMENSIONS TAKE PRECEDENCE TO SCALE

THIS DRAWING IS COPYRIGHT AND THE PROPERTY OF ROOMARK PTY LTD AND MUST NOT BE RETAINED,

USED OR COPIED FOR ANY PROJECT WITHOUT WRITTEN AUTHORITY FROM ROSSMARK PTY LTD

ROSSMARK PTY LTD LIC 114562C

11 ERSKINE ROAD CARINGBAH NSW 2229

T: 02 9525 5588 F: 02 9525 0111 E: [email protected]

@ A31 : 100

ISSUED FOR DEVELOPMENT APPLICATION

DA-06

PROPOSED FIRST FLOOR ADDITION

10A KOEL PLACE WORONORA HEIGHT NSW 2233

MR. & MRS. FARRELLJS

PROPOSED FIRST FLOOR ADDITION

PROPOSED GROUND FLOOR PLAN 0 51 2

SCALE 1:100

A ISSUED FOR DEVELOPMENT APPLICATION 22.11.21

A22.11.21

PROPOSED TOTAL FLOOR AREA : 137.45m²

PROPOSED GROSS FLOOR AREA : 100.95m²

NORTH

Page 7: PRELIMINARY SITE CALCULATIONS

UP

17

16

15

1413121110987654

3

2

1

FW

60%

SIT

E D

EP

TH

1050

ST

OR

E

9021

2090

1915

1370

3482

90

90 2030 90 1050 90 2880 90 3745 90

KIT

CH

EN

ET

TE

FL

UE

13.18sqm

LIVING

8.90sqm

STUDY

21.81sqm

MASTER

RO

BE

90

LIV

ING

3470

90

KIT

CH

EN

ET

TE

2885

9028

27

2959

0

BA

THR

OO

M

3175

9011

4090

910

90

MA

ST

ER

3482

90

85

BE

D 1

3475

9021

4074

590

BA

LCO

NY

2838

CUT BACK LOWER FLOOR ROOFS TO ACCOMMODATE PROPOSED UPPER FLOOR BALCONY . CHECK ON SITE REQUIRED.INSTALL PRIVACY SCREEN TO THE NORTHERN SIDE

BALCONY

TIMBER PORTHOLE WINDOW OVER BATHTUB.(OPTIONAL)

PROVIDE CONCEALED PLUMBING.KITCHENETTE TO BE INSTALLED AT A LATER DATE BY OWNER

VOID

820 ARCH OPENING820 ARCH OPENING

FULL LENGTH MIRROR

TIMBER PANEL DOORS

RA

SLIGHT BREECH OF THE 60 % SITE DEPTH - VARIATION WITH COUNCIL RQUIRED - 98mm

ARCH OVER SQUARE CAVITY

BULKHEAD OVER

200 1650 200

VELUX SKYLIGHT TO BATHROOM

5295 90 845 90 3745 90

1650

RO

BE

4305

4852

9157

10155

5295 4860

9452

2827

6625

10155

200 6500 3455

90 6320 90 3365 90

90 1830 90 1397 90 3730 2638 90

1DA-13

1DA-13

W09

D03

D04

W03

W04W05W06

W07

W08

AS

W13

15

AS

W12

18

ASW 0618ASW1218SA2_WINDOW_CIRCLE

SA

2_W

IND

OW

_CIR

CLE

AA

W 1

306

AS

T212

3

AST2123

RL 100.530

RL 100.495

ISSUED FOR DEVELOPMENT APPLICATION

NOT FOR CONSTRUCTION

DESCRIPTIONDATE

ADDRESS

CLIENT

DRAWN

DATE

SCALE

STATUS

DESCRIPTIONISSUE

DRAWING REVISIONNOTES:

- ALL DIMENSIONS ARE TO BE VERIFIED ON SITE BY THE BUILDER BEFORE COMMENCING WORK

- ALL WORKS MUST COMPLY WITH RELEVANT AUSTRALIAN BUILDING CODES AND AUSTRALIAN STANDARDS

- FINISHED FLOOR LEVEL REFERS TO INTERNAL FINISHED CONCRETE LEVEL

- WRITTEN DIMENSIONS TAKE PRECEDENCE TO SCALE

THIS DRAWING IS COPYRIGHT AND THE PROPERTY OF ROOMARK PTY LTD AND MUST NOT BE RETAINED,

USED OR COPIED FOR ANY PROJECT WITHOUT WRITTEN AUTHORITY FROM ROSSMARK PTY LTD

ROSSMARK PTY LTD LIC 114562C

11 ERSKINE ROAD CARINGBAH NSW 2229

T: 02 9525 5588 F: 02 9525 0111 E: [email protected]

@ A31 : 100

ISSUED FOR DEVELOPMENT APPLICATION

DA-07

PROPOSED FIRST FLOOR ADDITION

10A KOEL PLACE WORONORA HEIGHT NSW 2233

MR. & MRS. FARRELLJS

PROPOSED FIRST FLOOR ADDITION

PROPOSED FIRST FLOOR PLANEXISTING TOTAL FLOOR AREA : 93.81m² (INCLUSIVE OF BALCONY)

PROPOSED GROSS FLOOR AREA : 75.56m²

0 51 2

SCALE 1:100

NORTH

A ISSUED FOR DEVELOPMENT APPLICATION 22.11.21

A22.11.21

Page 8: PRELIMINARY SITE CALCULATIONS

UP

UP

1DA-13

1DA-13

SL01

FA

LL

FA

LL

FALLFALL

FA

LL

600

600

600

30560

0

600

NEW TIMBER FRAME ROOF OVER VAPOUR PERMEABLEMEMBRANE AND TIMBER ROOF BATTENS - PITCH AT 22

DEGREES - RE USE EXISTING TILES REMOVED FROMGROUND FLOOR - SHORTFALL ON TILES TO MATCH

EXISTING COLOUR AND PROFILE

NEW COLORBOND METAL GUTTERING, FASCIA ANDDOWNPIPES - CONNECT TO EXISTING STORMWATER

DRAINAGE SYSTEM

ISSUED FOR DEVELOPMENT APPLICATION

NOT FOR CONSTRUCTION

DESCRIPTIONDATE

ADDRESS

CLIENT

DRAWN

DATE

SCALE

STATUS

DESCRIPTIONISSUE

DRAWING REVISIONNOTES:

- ALL DIMENSIONS ARE TO BE VERIFIED ON SITE BY THE BUILDER BEFORE COMMENCING WORK

- ALL WORKS MUST COMPLY WITH RELEVANT AUSTRALIAN BUILDING CODES AND AUSTRALIAN STANDARDS

- FINISHED FLOOR LEVEL REFERS TO INTERNAL FINISHED CONCRETE LEVEL

- WRITTEN DIMENSIONS TAKE PRECEDENCE TO SCALE

THIS DRAWING IS COPYRIGHT AND THE PROPERTY OF ROOMARK PTY LTD AND MUST NOT BE RETAINED,

USED OR COPIED FOR ANY PROJECT WITHOUT WRITTEN AUTHORITY FROM ROSSMARK PTY LTD

ROSSMARK PTY LTD LIC 114562C

11 ERSKINE ROAD CARINGBAH NSW 2229

T: 02 9525 5588 F: 02 9525 0111 E: [email protected]

@ A31 : 100

ISSUED FOR DEVELOPMENT APPLICATION

DA-08

PROPOSED FIRST FLOOR ADDITION

10A KOEL PLACE WORONORA HEIGHT NSW 2233

MR. & MRS. FARRELLJS

PROPOSED FIRST FLOOR ADDITION

WINDOW SCHEDULE

Mark Location Type Width Height Stud Opening Material Glazing Remarks

SL01 First Floor - Bathroom Skylight 700 X 580 580 700 580x700 Aluminium Low E / Argon / Clear

W01 Ground Floor - Living AAW 1309 970 1370 1026x2166 Aluminium Single Clear

W02 Ground FLoor Kitchen BiFold 1225 2510 1200 2566x1266 Aluminium Single Clear

W03 First Floor - Living ASW1218 1810 1200 1866x1266 Aluminium Single Clear

W04 First Floor - Living ASW 0618 1810 600 1866x666 Aluminium Single Clear

W05 First Floor - Study ASW1218 1810 1200 1866x1266 Aluminium Single Clear

W06 First Floor - Bathroom SA2_WINDOW_CIRCLE 800 800 CUSTOM Aluminium Single Clear

W07 First Floor - Bathroom SA2_WINDOW_CIRCLE 800 800 CUSTOM Aluminium Single LOW E

W08 First Floor - Walk in Robe AAW 1306 610 1370 666x1436 Aluminium Single LOW E

W09 First Floor Master Bedroom ASW1315 1570 1370 1626x1436 Aluminium Single LOW E

PROPOSED ROOF PLAN

0 51 2

SCALE 1:100

NORTH

Door Schedule

Mark Location Type Width Height Door Stud Opening Frame Material Door Glazing Comments

D01 Ground Floor - Living Glazed Swing Single 820 820 2100 846 X 2140 Aluminium Clear

D02 Ground Floor - Kitchen ASD 2127 2684 2100 2740 X 2140 Aluminium Clear

D03 First Floor - Master AST2123 2324 2100 2380 X 2140 Aluminium Clear

D04 First Floor - Master AST2123 2324 2100 2380 X 2140 Aluminium Clear

A ISSUED FOR DEVELOPMENT APPLICATION 22.11.21

A22.11.21

Page 9: PRELIMINARY SITE CALCULATIONS

ISSUED FOR DEVELOPMENT APPLICATION

NOT FOR CONSTRUCTION

RL02 FFL Ground Floor 97.560

RL03 CL Ground Floor 99.945

RL04 FFL First Floor 100.530

RL05 CL First Floor 103.125

RL06 Ridge 105.137

2012

2595

585

2385

7577

W09 W08

W07

EXISTINGEXISTING

D05

NEW TIMBER FRAME ROOF OVER VAPOUR PERMEABLEMEMBRANE AND TIMBER ROOF BATTENS - PITCH AT 22

DEGREES - RE USE EXISTING TILES REMOVED FROMGROUND FLOOR - SHORTFALL ON TILES TO MATCH

EXISTING COLOUR AND PROFILE

SUPPLY AND INSTALL "WEATHERTEX" WEATHERBOARDCLADDING OVER MOISTURE BARRIER AND PERMEABLE

VAPOUR BARRIER

POWDERCOAT FINISH ALUMINIUM FRAMED OPENING -REFER TO WINDOW AND DOOR SCHEDULES - ALUMINIUM

HEAD HEIGHT @ 2100

NEW COLORBOND METAL GUTTERING, FASCIA ANDDOWNPIPES - CONNECT TO EXISTING STORMWATERDRAINAGE SYSTEM

600EAVE OVERHANG

RLFFL Garage 98.200

8.5m MAX BUILDING HEIGHT

EXISTING GROUND LINE

EXISTING RESIDENCE

PROPOSED ADDITION

DESCRIPTIONDATE

ADDRESS

CLIENT

DRAWN

DATE

SCALE

STATUS

DESCRIPTIONISSUE

DRAWING REVISIONNOTES:

- ALL DIMENSIONS ARE TO BE VERIFIED ON SITE BY THE BUILDER BEFORE COMMENCING WORK

- ALL WORKS MUST COMPLY WITH RELEVANT AUSTRALIAN BUILDING CODES AND AUSTRALIAN STANDARDS

- FINISHED FLOOR LEVEL REFERS TO INTERNAL FINISHED CONCRETE LEVEL

- WRITTEN DIMENSIONS TAKE PRECEDENCE TO SCALE

THIS DRAWING IS COPYRIGHT AND THE PROPERTY OF ROOMARK PTY LTD AND MUST NOT BE RETAINED,

USED OR COPIED FOR ANY PROJECT WITHOUT WRITTEN AUTHORITY FROM ROSSMARK PTY LTD

ROSSMARK PTY LTD LIC 114562C

11 ERSKINE ROAD CARINGBAH NSW 2229

T: 02 9525 5588 F: 02 9525 0111 E: [email protected]

@ A31 : 100

ISSUED FOR DEVELOPMENT APPLICATION

DA-09

PROPOSED FIRST FLOOR ADDITION

10A KOEL PLACE WORONORA HEIGHT NSW 2233

MR. & MRS. FARRELLJS

PROPOSED FIRST FLOOR ADDITION

PROPOSED NORTH WEST ELEVATION

0 51 2

SCALE 1:100

A ISSUED FOR DEVELOPMENT APPLICATION 22.11.21

A22.11.21

Page 10: PRELIMINARY SITE CALCULATIONS

ISSUED FOR DEVELOPMENT APPLICATION

NOT FOR CONSTRUCTION

RL02 FFL Ground Floor 97.560

RL03 CL Ground Floor 99.945

RL04 FFL First Floor 100.530

RL05 CL First Floor 103.125

RL06 Ridge 105.137

7577

2385

585

2595

2012

EXISTING

D02

D04

W02

NEW COLORBOND METAL GUTTERING, FASCIA ANDDOWNPIPES - CONNECT TO EXISTING STORMWATER

DRAINAGE SYSTEM

ALUMINIUM FRAMED OPENING - REFER TO WINDOW ANDDOOR SCHEDULES - HEAD HEIGHT @ 2100

STRUCTURAL COLUMN - TO ENGINEERS DESIGN ANDDETAIL

SUPPLY AND INSTALL "WEATHERTEX" WEATHERBOARDCLADDING OVER MOISTURE BARRIER AND PERMEABLEVAPOUR BARRIER

NEW TIMBER FRAME ROOF OVER VAPOUR PERMEABLEMEMBRANE AND TIMBER ROOF BATTENS - PITCH AT 22DEGREES - RE USE EXISTING TILES REMOVED FROMGROUND FLOOR - SHORTFALL ON TILES TO MATCH EXISTINGCOLOUR AND PROFILE

600

DELETE EXISTING OPENINGS AND INSTALL NEW STACKER DOORS AND BIFOLD WINDOW - MAKE

GOOD AFFECTED SURFACES

EAVE OVERHANG

RLFFL Garage 98.200

8.5m MAX BUILDING HEIGHT

EXISTING GROUND LINE

EXISTING RESIDENCE

DESCRIPTIONDATE

ADDRESS

CLIENT

DRAWN

DATE

SCALE

STATUS

DESCRIPTIONISSUE

DRAWING REVISIONNOTES:

- ALL DIMENSIONS ARE TO BE VERIFIED ON SITE BY THE BUILDER BEFORE COMMENCING WORK

- ALL WORKS MUST COMPLY WITH RELEVANT AUSTRALIAN BUILDING CODES AND AUSTRALIAN STANDARDS

- FINISHED FLOOR LEVEL REFERS TO INTERNAL FINISHED CONCRETE LEVEL

- WRITTEN DIMENSIONS TAKE PRECEDENCE TO SCALE

THIS DRAWING IS COPYRIGHT AND THE PROPERTY OF ROOMARK PTY LTD AND MUST NOT BE RETAINED,

USED OR COPIED FOR ANY PROJECT WITHOUT WRITTEN AUTHORITY FROM ROSSMARK PTY LTD

ROSSMARK PTY LTD LIC 114562C

11 ERSKINE ROAD CARINGBAH NSW 2229

T: 02 9525 5588 F: 02 9525 0111 E: [email protected]

@ A31 : 100

ISSUED FOR DEVELOPMENT APPLICATION

DA-10

PROPOSED FIRST FLOOR ADDITION

10A KOEL PLACE WORONORA HEIGHT NSW 2233

MR. & MRS. FARRELLJS

PROPOSED FIRST FLOOR ADDITION

0 51 2

SCALE 1:100PROPOSED NORTH EAST ELEVATION

A ISSUED FOR DEVELOPMENT APPLICATION 22.11.21

A22.11.21

Page 11: PRELIMINARY SITE CALCULATIONS

RL02 FFL Ground Floor 97.560

RL03 CL Ground Floor 99.945

RL04 FFL First Floor 100.530

RL05 CL First Floor 103.125

RL06 Ridge 105.137

7577

2012

2595

585

2385

W03

W01

D01

EXISTING

D03

ALUMINIUM FRAMED OPENING - REFER TO WINDOW ANDDOOR SCHEDULES - HEAD HEIGHT @ 2100

STRUCTURAL COLUMN - TO ENGINEERS DESIGN AND DETAIL

POWDERCOAT FINISH ALUMINIUM FRAMED OPENING - REFERTO WINDOW AND DOOR SCHEDULES - ALUMINIUM HEADHEIGHT @ 2100

NEW COLORBOND METAL GUTTERING, FASCIA ANDDOWNPIPES - CONNECT TO EXISTING STORMWATERDRAINAGE SYSTEM

PROPOSED NEW DECK TO FIRST FLOOR ADDITION - TOENGINEERS DESIGN AND DETAIL

POWDERCOAT FINISH ALUMINIUM FRAMED OPENING -REFER TO WINDOW AND DOOR SCHEDULES - ALUMINIUM

HEAD HEIGHT @ 2100

SUPPLY AND INSTALL "WEATHERTEX" WEATHERBOARDCLADDING OVER MOISTURE BARRIER AND PERMEABLE

VAPOUR BARRIER

NEW TIMBER FRAME ROOF OVER VAPOUR PERMEABLEMEMBRANE AND TIMBER ROOF BATTENS - PITCH AT 22

DEGREES - RE USE EXISTING TILES REMOVED FROMGROUND FLOOR - SHORTFALL ON TILES TO MATCH

EXISTING COLOUR AND PROFILE

600 EAVE OVERHANG

RLFFL Garage 98.200

8.5m MAX BUILDING HEIGHT

EXISTING GROUND LINE

EXISTING RESIDENCE

PROPOSED ADDITION

DESCRIPTIONDATE

ADDRESS

CLIENT

DRAWN

DATE

SCALE

STATUS

DESCRIPTIONISSUE

DRAWING REVISIONNOTES:

- ALL DIMENSIONS ARE TO BE VERIFIED ON SITE BY THE BUILDER BEFORE COMMENCING WORK

- ALL WORKS MUST COMPLY WITH RELEVANT AUSTRALIAN BUILDING CODES AND AUSTRALIAN STANDARDS

- FINISHED FLOOR LEVEL REFERS TO INTERNAL FINISHED CONCRETE LEVEL

- WRITTEN DIMENSIONS TAKE PRECEDENCE TO SCALE

THIS DRAWING IS COPYRIGHT AND THE PROPERTY OF ROOMARK PTY LTD AND MUST NOT BE RETAINED,

USED OR COPIED FOR ANY PROJECT WITHOUT WRITTEN AUTHORITY FROM ROSSMARK PTY LTD

ROSSMARK PTY LTD LIC 114562C

11 ERSKINE ROAD CARINGBAH NSW 2229

T: 02 9525 5588 F: 02 9525 0111 E: [email protected]

@ A31 : 100

ISSUED FOR DEVELOPMENT APPLICATION

DA-11

PROPOSED FIRST FLOOR ADDITION

10A KOEL PLACE WORONORA HEIGHT NSW 2233

MR. & MRS. FARRELLJS

PROPOSED FIRST FLOOR ADDITION

PROPOSED SOUTH EAST ELEVATION

0 51 2

SCALE 1:100

A ISSUED FOR DEVELOPMENT APPLICATION 22.11.21

A22.11.21

Page 12: PRELIMINARY SITE CALCULATIONS

RL02 FFL Ground Floor 97.560

RL03 CL Ground Floor 99.945

RL04 FFL First Floor 100.530

RL05 CL First Floor 103.125

RL06 Ridge 105.137

7577

2012

2595

585

2385

W06W05

W04

NEW TIMBER FRAME ROOF OVER VAPOUR PERMEABLEMEMBRANE AND TIMBER ROOF BATTENS - PITCH AT 22DEGREES - RE USE EXISTING TILES REMOVED FROMGROUND FLOOR - SHORTFALL ON TILES TO MATCH EXISTINGCOLOUR AND PROFILE

SUPPLY AND INSTALL "WEATHERTEX" WEATHERBOARDCLADDING OVER MOISTURE BARRIER AND PERMEABLEVAPOUR BARRIER

600

NEW COLORBOND METAL GUTTERING, FASCIA ANDDOWNPIPES - CONNECT TO EXISTING STORMWATER

DRAINAGE SYSTEM

POWDERCOAT FINISH ALUMINIUM FRAMED OPENING -REFER TO WINDOW AND DOOR SCHEDULES - ALUMINIUM

HEAD HEIGHT @ 2100

SL01

600EAVE OVERHANGEAVE OVERHANG

RLFFL Garage 98.200

8.5m MAX BUILDING HEIGHT

EXISTING GROUND LINE

EXISTING RESIDENCE

PROPOSED ADDITION

EX.

EX.

EX. EX. EX.EX.

DESCRIPTIONDATE

ADDRESS

CLIENT

DRAWN

DATE

SCALE

STATUS

DESCRIPTIONISSUE

DRAWING REVISIONNOTES:

- ALL DIMENSIONS ARE TO BE VERIFIED ON SITE BY THE BUILDER BEFORE COMMENCING WORK

- ALL WORKS MUST COMPLY WITH RELEVANT AUSTRALIAN BUILDING CODES AND AUSTRALIAN STANDARDS

- FINISHED FLOOR LEVEL REFERS TO INTERNAL FINISHED CONCRETE LEVEL

- WRITTEN DIMENSIONS TAKE PRECEDENCE TO SCALE

THIS DRAWING IS COPYRIGHT AND THE PROPERTY OF ROOMARK PTY LTD AND MUST NOT BE RETAINED,

USED OR COPIED FOR ANY PROJECT WITHOUT WRITTEN AUTHORITY FROM ROSSMARK PTY LTD

ROSSMARK PTY LTD LIC 114562C

11 ERSKINE ROAD CARINGBAH NSW 2229

T: 02 9525 5588 F: 02 9525 0111 E: [email protected]

@ A31 : 100

ISSUED FOR DEVELOPMENT APPLICATION

DA-12

PROPOSED FIRST FLOOR ADDITION

10A KOEL PLACE WORONORA HEIGHT NSW 2233

MR. & MRS. FARRELLJS

PROPOSED FIRST FLOOR ADDITION

PROPOSED SOUTH WEST ELEVATION

0 51 2

SCALE 1:100

A ISSUED FOR DEVELOPMENT APPLICATION 22.11.21

A22.11.21

Page 13: PRELIMINARY SITE CALCULATIONS

PRE PRIMED TIMBER BATTEN 42X11

WEATHERTEX CLADDING

BREATHABLE SARKING / MEMBRANE(FLAMMABILITY INDEX NO GREATER THAN 5)

90mm TIMBER WALL FRAME (T2 TERMITE TREATMENT)

PLASTERBOARD INTERNAL LINING

CAVITY BATTEN

ISSUED FOR DEVELOPMENT APPLICATION

NOT FOR CONSTRUCTION

FRAME AND GLAZINGSTANDARD ALUMINIUM SINGLE CLEAR U-VALUE 7.63 SHGC 0.75

MINIMUM 40% OF NEW OR ALTERED LIGHT FIXTURES ARE FITTEDWITH FLUORESCENT, COMPACT FLUORESCENT OR LIGHT EMITTING DIODE (LED) LAMPS.

FLOOR ABOVE EXISTING DWELLING OR BUILDING: NIL

EXTERNAL WALL: FRAMED (WEATHERBOARD, FIBRO, METAL CLAD)R1.30 (OR R1.70 INCLUDING CONSTRUCTION)

FLAT CEILING, PITCHED ROOF: CEILING: R1.45(UP), ROOF: FOIL BACKED BLANKETMEDIUM (SOLAR ABSORBANCE 0.475-0.70)

NEW OR ALTERED TOILETS, TAPS OR SHOWERHEADS TO BE MINIMUM 3 STAR RATING

BASIX COMMITMENTS

WINDOWS

LIGHTING

INSULATION

FIXTURES

W01 / W02 / W03 / W04 / W05 / W06 / D01 / D02 / D03 / D04

FRAME AND GLAZINGSTANDARD ALUMINIUM SINGLE CLEAR U-VALUE 7.63 SHGC 0.75

W07 / W08 / W09

RL02 FFL Ground Floor 97.560

RL03 CL Ground Floor 99.945

RL04 FFL First Floor 100.530

RL05 CL First Floor 103.125

RL06 Ridge 105.137

D04

D02

RLFFL Garage 98.200

7577

2012

2595

585

2385

W02

NEW TIMBER FRAME ROOF OVER VAPOUR PERMEABLEMEMBRANE AND TIMBER ROOF BATTENS - PITCH AT 22DEGREES - RE USE EXISTING TILES REMOVED FROMGROUND FLOOR - SHORTFALL ON TILES TO MATCH EXISTINGCOLOUR AND PROFILE

NEW COLORBOND METAL GUTTERING, FASCIA ANDDOWNPIPES - CONNECT TO EXISTING STORMWATERDRAINAGE SYSTEM

SUPPLY AND INSTALL "WEATHERTEX" WEATHERBOARDCLADDING OVER MOISTURE BARRIER AND PERMEABLEVAPOUR BARRIER

ALUMINIUM FRAMED OPENING - REFER TO WINDOW ANDDOOR SCHEDULES - HEAD HEIGHT @ 2100

600

8.5m MAX BUILDING HEIGHT

EXISTING GROUND LINE

2222

DESCRIPTIONDATE

ADDRESS

CLIENT

DRAWN

DATE

SCALE

STATUS

DESCRIPTIONISSUE

DRAWING REVISIONNOTES:

- ALL DIMENSIONS ARE TO BE VERIFIED ON SITE BY THE BUILDER BEFORE COMMENCING WORK

- ALL WORKS MUST COMPLY WITH RELEVANT AUSTRALIAN BUILDING CODES AND AUSTRALIAN STANDARDS

- FINISHED FLOOR LEVEL REFERS TO INTERNAL FINISHED CONCRETE LEVEL

- WRITTEN DIMENSIONS TAKE PRECEDENCE TO SCALE

THIS DRAWING IS COPYRIGHT AND THE PROPERTY OF ROOMARK PTY LTD AND MUST NOT BE RETAINED,

USED OR COPIED FOR ANY PROJECT WITHOUT WRITTEN AUTHORITY FROM ROSSMARK PTY LTD

ROSSMARK PTY LTD LIC 114562C

11 ERSKINE ROAD CARINGBAH NSW 2229

T: 02 9525 5588 F: 02 9525 0111 E: [email protected]

@ A3As indicated

ISSUED FOR DEVELOPMENT APPLICATION

DA-13

PROPOSED FIRST FLOOR ADDITION

10A KOEL PLACE WORONORA HEIGHT NSW 2233

MR. & MRS. FARRELLJS

PROPOSED FIRST FLOOR ADDITION

PROPOSED SECTION AND DETAILS

0 51 2

SCALE 1:100

A ISSUED FOR DEVELOPMENT APPLICATION 22.11.21

A22.11.21