Price Schedule Q-Aligarh

Embed Size (px)

Citation preview

  • 8/4/2019 Price Schedule Q-Aligarh

    1/50

    SCHEDULE -Q

    PREAMBLE

    1 The Schedule of Quantities shall be read in conjucntion with all other sections of these tender

    documents. The brief descriptions of equipments/items given in price schedule shall not be construed

    to limit the scope of work, and the same shall be read in conjunction with corresponding sections ofspecifications including amendments/errata if any, thereto. Reference to the all sections of the tender

    document shall be made before entering prices against each itmes in the Schedule of Quantities.

    2 The quantities given in the Schedule of Quantites are estimated and provisional and are given to

    provide a common basis for bidding. The basis of payment will be the actual quantities of works

    ordered and carried out, as measured by the Contractor and verified by the Purchaser and valued at

    the unit/lump sum rate mentioned in the price schedule where applicable and otherwise at such rates

    and prices as the Purchaser may fix within the terms of the Contract.

    3 The rates and prices shall include all constructional plant, labour, supervision, materials, erection ,

    maintenance, insurance, profit, taxes and duties, together with all general risks, liabilities andobligations set out or implied in the contract. The erection charges shall include supply of all non-

    consumable/ consumable items for handling, erection, testing & commissioning of

    equipments/strucutures etc. without any extra liability on UPPTCL. Where ever applicable the

    quipments shall be supplied with suitable terminal connectors, first fill of oil & 10% extra oil and all

    other required accessroy items to make the equipment complete whether specified or not.

    4 The Contractor shall be entirely responsible for completeness of work in all respects irrespective of

    whether any item is specifically mentioned in price schedule. The tenderer shall quote for all such

    items or works, which in tenderer's view have not been included in price schedule but are necessary

    for completion of work, either on lump sum basis or by indicating their estimated quantities & their

    unit/lot rates, otherwise these shall be deemed to have been included in tenderer's scope without any

    extra liability to UPPTCL. The cost shall be deemed to be distributed among the rates and prices

    entered for the related items of supply & work.

    5 The method of measurement of completed work of payment shall be in accordance with relevant

    I.S.S. Codes.

    6 Rate and price shall be quoted by the bidder in Inidan rupee.

    7 Where there is a discrepancy between the amounts in figure and words, the amounts in words will

    govern.

    8 Where there is a discrepancy between the unit and line item total resulting from multiplying the unitrate by the quantity, the unit rate as quoted will govern.

    9 In case prices for any items are found left bank or against which"__" is indicated, the prices of such

    itmes shall be deemed to be included in associated items or in grand total of price schedule.

    10 No Excise duty & sales tax shall be payable by UPPTCL on bought-out items which shall be

    dispatched by Contractor's sub-vendors directly to UPPTCL project site on sale-in-transit basis, these

    shall be paid extra in case of direct transaction items between Contractor & UPPTCL.

    SCHEDULE OF QUNATITIES & PRICES FOR EPC

    (ENGINEERING,PROCUREMENT,CONSTRUCTION) CONTRACT FOR

    400 kV SUBSTATION ALIGARH

  • 8/4/2019 Price Schedule Q-Aligarh

    2/50

    SCHESCHEDULE OF QUANTITIES AND PRICES FOR 400 KV S/S ALIGARH

    SUPPLY CHARGES

    ( All PEQUIPMENT / ITEM Unit Qty. Direct su ly Unit Unit Freight Total FOR

    or Bought-out Ex-Works & Insurance destination ED C

    Sale in Transit Prices charges prices

    1 2 3 4 5 6 7 8 9 1

    Part-A : UPPTCL ASSESSED QUANTITIES

    A. TRANSFORMERS & REACTORS

    1 AUTO TRANSFORMERS

    1.1 500 MVA , 400/220/33 kV AutoTransformer (3-Phase) Nos. 2

    2 LT TRANSFORMER

    2.1 630KVA , 33/0.415 KV Transformers (3-Phase) Nos. 2

    3 BUS REACTOR

    3.1 420 kV,63 MVAR BUS REACTOR (3-Phase) No. 1

    4 LINE REACTOR

    4.1 Dismantling & shifting of 420 kV, 50 MVAR Line

    Reactor (3-Phase) alongwith NGR & LA from 400 kV

    S/S Muradnagar to 400 kV S/S Aligarh and their re-

    erection for 400kV S/S Aligarh-400 kV Muradnagar

    Line

    LS 1 NA NA NA NA NA N

    Ta

    (complete with all fittings, accessories, associated

    equipments etc. as specified in Technical

    S ecifications)

    Sl No.

    Q-1 Aligarh P

  • 8/4/2019 Price Schedule Q-Aligarh

    3/50

    B. 400kV EQUIPMENT

    1 420kV Circuit Breakers (3-Phase) with support

    structurea. 3150A, 40KA with closing resistor Nos. 3

    b. 3150A, 40KA without closing resistor Nos. 12

    2 420 kV Current Transformer (1-Phase)

    a. 3000A, 40KA with 120% extended current rating Nos. 45

    3 420kV Isolator (3-phase) (Double Break)

    a. 3150A, 40KA, isolator with one E/S (Metalics only) Set 41b. Support Insulator for above Set 41

    c. 3150A, 40KA, isolator with two E/S (Metalics only) Set 2

    d. Support Insulator for above Set 2

    4 390 KV Surge Arrester (1-phase) Nos. 30

    5 420 kV Capacitive Voltage Transformer (1-phase)

    ( 4400 pF )

    Nos. 24

    6 420 kV Bus Post Insulator (Except for wave traps) Nos. 72

    C. 220kV EQUIPMENT1 245 kV Circuit Breakers (3-Phase) with support

    structurea. 1600A, 40KA Nos. 8

    b. 2500A, 40KA Nos. 1

    2 245 kV Current Transformer (1-Phase)a. 1600A, 40KA with 120% extended current rating Nos. 24

    b. 1600A, 40KA with 150% extended current rating Nos. 3

    3 245 kV Capacitive Voltage Transformer (1- Phase)

    ( 4400 F )

    Nos. 21

    4 245kV Isolator (3-phase)-Double Break

    a. 1600A, 40 KA, Isolator with one E/S(Metalics only) Set 8

    b. Support Insulator for above Set 8

    c. 1600A, 40 KA, Isolator with two E/S(Metalics only) Set 8

    d. Support Insulator for above Set 8

    e. 1600 A, 40KA, Tandem Isolator without E/S(Metalics

    only)

    Set 15

    f. Support Insulator for above Set 15

    g. 2500 A, 40KA, Isolator with 2 E/S(Metalics only) Set 2

    Q-1 Aligarh

  • 8/4/2019 Price Schedule Q-Aligarh

    4/50

    h. Support Insulator for above Set 2

    5 216 kV Surge Arrestors (1-phase) Nos. 21

    6 245 kV Bus Post Insulator (Except for wave traps) Nos. 98

    D 72.5kV EQUIPMENT1 72.5kV Circuit Breaker (3-Ph.) along with support

    structurea. 1250A,25kA Nos. 1

    2 72.5kV Isolator (3-Ph) (Horizontal double break)

    a. 630A, 25kA, Isolator with 1 E/S (Metalics only) Set 1

    b. Support Insulator for above Set 1

    3 72.5kV Current transformer (1-Ph.)a. 50A,25kA with 120% extended rating Nos. 3

    4 72.5kV Voltage Transformer (1-Ph.) Nos. 3

    5 72.5kV BPI Nos. 5

    E 36kV EQUIPMENT

    1 36kV Isolator (3-Ph) (Horizontal double break)a. 630A,25kA, Isolator with 1 E/S (Metalics only) Set 1

    b. Support Insulator for above Set 1

    2 30kV Surge Arrestor (1-Ph.) Nos. 3

    3 36kV Horn gap fuse (1-Ph.) Nos. 3

    F CONTROL & RELAY PANELI) 400 kV1 Circuit Breaker Relay Panel

    a. With Auto Reclose Nos. 12

    b. Without Auto Reclose Nos. 3

    2 Line Protection Panel Nos. 6

    3 Transformer Protection Panel (For both HV & MV side) Nos. 2

    4 Reactor protection Panel Nos. 2

    5 Bus Bar Protection Panel

    a. 400kV (Duplicate bus bar protection) Nos. 1

    II) 220 kV1 Circuit Breaker Relay Panel

    a. With Auto Reclose Nos. 6

    Q-1 Aligarh

  • 8/4/2019 Price Schedule Q-Aligarh

    5/50

    b. Without Auto Reclose Nos. 3

    2 Line Protection Panel Nos. 5

    3 Bus Bar Protection Panel

    a. 220kV (Single bus bar protection) Nos. 1

    III) 72.5 kV1 Circuit Breaker Relay Panel

    a. Without Auto Reclose No. 1

    G Other/common Equipments1 Time synchronisation equipment Nos. 1

    H SUBSTATION AUTOMATION

    Complete Substation automation system for 400/220kV

    substation as per technical specification

    1 400kV Bays (Main Bays + Tie Bays ) Nos. 15

    2 220kV Bays Nos. 9

    3 BCUs for controll ing and monitoring of auxil iary system Set 1

    I PLCC

    i) PLCC At 400 kV S/S Aligarh1 Line traps

    a. 3150A, 400kV, 40KA,1.0 mH Line Trap Nos. 12

    b. BPI for above Nos. 36

    c. 1600A, 245kV, 40KA, 0.5mH Line Trap Nos. 10

    d. BPI for above Nos. 30

    2 PLCC Cabinets

    a Carrier equipment ( Speech+data+protection) Nos. 14

    b Carrier equipment ( Speech+data) Nos. 9

    3 Coupling device (2 LMU + 1 BT) Sets 11

    4 EPAX (24/8) with 24 nos telephones, cable etc Set 1

    5 4 wire telephone instrument( Along with telephone

    wiring )

    Nos. 1

    6 HF cable km 1

    ii) PLCC For Mainpuri (765 kV S/S) End

    1 PLCC Cabinets

    a Carrier equipment ( Speech+data+protection) Nos. 4

    b Carrier equipment ( Speech+data) Nos. 2

    2 Coupling device (2 LMU + 1 BT) Sets 2

    Q-1 Aligarh

  • 8/4/2019 Price Schedule Q-Aligarh

    6/50

    3 HF cable km 0.5

    iii) PLCC For 400 kV S/S Sikandrabad End

    Q-1 Aligarh

  • 8/4/2019 Price Schedule Q-Aligarh

    7/50

    1 PLCC Cabinets

    a Carrier equipment ( Speech+data+protection) Nos. 4

    b Carrier equipment ( Speech+data) Nos. 2

    2 Coupling device (2 LMU + 1 BT) Sets 2

    3 HF cable km 0.5

    iv) PLCC For 400 kV S/S Muradnagar End1 PLCC Cabinets

    a Carrier equipment ( Speech+data+protection) Nos. 2b Carrier equipment ( Speech+data) Nos. 1

    iv) PLCC For 400 kV S/S Panki End1 PLCC Cabinets

    a Carrier equipment ( Speech+data+protection) Nos. 2

    b Carrier equipment ( Speech+data) Nos. 1

    v) PLCC For 220 kV S/S Atrauli End1 PLCC Cabinets

    a Carrier equipment ( Speech+data+protection) Nos. 2

    b Carrier equipment ( Speech+data) Nos. 2

    2 Coupling device (2 LMU + 1 BT) Sets 2

    3 HF cable km 0.5

    vi) PLCC For 220 kV S/S Khair End1 PLCC Cabinets

    a Carrier equipment ( Speech+data+protection) Nos. 1

    b Carrier equipment ( Speech+data) Nos. 1

    2 Coupling device (2 LMU + 1 BT) Sets 1

    3 HF cable km 0.25

    vii) PLCC For 220 kV S/S Hathras End

    1 PLCC Cabinets

    a Carrier equipment ( Speech+data+protection) Nos. 1

    Q-1 Aligarh

  • 8/4/2019 Price Schedule Q-Aligarh

    8/50

    b Carrier equipment ( Speech+data) Nos. 1

    2 Dismantling & Shifting of PLCC cabinets from 220 kV

    S/S Hathras to 400 kV S/S Aligarh and their re-erection

    for 400kV S/S Aligarh-220 kV Harduaganj Line

    LS 1 NA NA NA NA NA

    J LT SWITCHGEAR

    1 415V Main switchboard Set 12 415V ACDB Set 1

    3 415V MLDB Set 1

    4 415V Emergency LDB Set 1

    5 220V DCDB Sets 2

    6 48V DCDB Sets 2

    K BATTERIES/BATTERY CHARGER

    1 220V Batterya) 600 AH Sets 2

    2 48V Batterya) 800 AH Sets 2

    3 Float cum Boost Battery Chargera) 220V (60/60 Amp.) Sets 2

    b) 48V (80/80 Amp) Sets 2

    L DG Set along with Control panel (250 kVA ) Set 1

    M Fire Protection System

    1 For Switchyard Panel Room

    a. 4.5kg CO2 Type Portable Fire Extinguishers Nos. 11

    2 For Control Room Building and Fire Fighting Pump

    House

    a. Portable/Trolley/Wheel mounted extinguishers

    i. 9 litre water type Nos. 5

    ii. 4.5kg DCP type Nos. 5

    iii. 4.5kg CO2 type Nos. 5

    3 For LT Transformer

    a. 50 Litres Mechanical Foam Type

    Portable/Trolley/wheel mounted extinguishers

    Nos. 2

    Q-1 Aligarh

  • 8/4/2019 Price Schedule Q-Aligarh

    9/50

    N Air Conditioning System1 High Wall type split AC Unit of 2 TR Capacity Nos. 12

    O Illumination System

    I) Control Room Cum Administrative Office Building:

    1 Lighting Panel

    a Lighting Panel (Indoor) Type ACP-1 as per technicalspecification Nos. 3

    b Lighting Panel (Indoor) Type DCP as per technical

    specification

    No. 1

    2 Lighting fixtures and Receptacles (including

    accessories/ materials etc. as per requirement like

    junction box, cable/wires, flexible conduit (if required)

    from junction box to lighting fixture, mounting

    arrangements)a Lighting Fixture Type-FI as per technical specification Nos. 32

    b Lighting Fixture Type-DLR as per as per technical Nos. 3

    c Lighting Fixture Type-FF as per technical specification Nos. 63

    d Lighting Fixture Type-DSM as per as per technical

    specification

    Nos. 25

    e Lighting Fixture Type-IB as per technical specification Nos. 8

    f Lighting Fixture Type-BH as per technical specification Nos. 18

    g Lighting Fixture Type-SL as per technical specification Nos. 6

    h Lighting Fixture Type-TL as per technical specification Nos. 5

    i 5/15 A, 240V: Indoor Receptacle 3-pin type (Type RI) Nos. 40

    j 15A, 240V: Outdoor Receptacle 2 pole, 3-pin type

    (Type RO)

    Nos. 10

    k 63A, 415V : Interlocked switch socket outdoor

    Receptacle (Type RP)

    No. 1

    3 Switchboards

    Q-1 Aligarh

  • 8/4/2019 Price Schedule Q-Aligarh

    10/50

    a Modular switchboard with 4 nos. 5 Amp. Switches and

    1 no. 5/15 Amp. Receptacle

    Nos. 20

    b Modular switchboard with 6 nos. 5 Amp. Switches Nos. 20

    c Modular switchboard with 2 nos. 5 Amp. Switches Nos. 10

    d Adiitional 2 modules and Eletronic Step Regulator to

    be mounted in the above switch boards

    Nos. 20

    4 Ceiling Fans

    a 1400mm sweep with electronic Step regulator Nos. 20

    5 Exhaust fans Nos. 66 Wall mounted fans 400 mm sweep Nos. 6

    7 Conduits & Wires

    a) Heavy duty PVC conduits as of 20/25/32 mm size

    complete with all accessories for Point wiring for Light

    points , Fans power points 5/15 amps with 2.5 sq mm

    /4 sqmm/6.0 Sq mm copper for circuit wiring and 1.5

    sq mm copper earth wire PVC isulated in green

    colourt including wiring for submains i.e. wiring from

    Lighting Panel to Switch boards.

    Nos 278

    b) Wiring from lighting panel to switch boards, from

    switchboards to junction boxes for Light Points,

    Submain, Power and Fan points with 2.5/4.0/6.0 Sq

    mm Copper wire as per technical specifications,

    complete in all respects.1.5 sq mm copper wire

    Nos 256

    8 Wire for Telephone

    a) Telephone cables screenede with annealed tin

    conductor and PVC insulation of 20 pair , 10 pair and

    2pair as required for wiring requirement of 24/8 line

    exchange

    LS 1

    b) Telehone Junction boxes/tag blocks to suit

    requirement of 24/8 telephone connections within the

    control room building , adminstrative block and fire

    fighting buliding

    LS 1

    c) Telephone sockets

    1 Single socket outlet comprising RJ-11 Socket Nos. 20

    2 Dual socket outlet comprising RJ-45 Socket Nos. 24

    Q-1 Aligarh

  • 8/4/2019 Price Schedule Q-Aligarh

    11/50

    9 Occupany sensors and other accessories as required

    for control of lighting in Control Room, ACDB & DCDB

    room, Battery room and Electrical Test Lab

    Set 7

    10 Junction Boxes with 4 nos. of terminal blocks for indoor

    lighting excluding junction box supplied alongwith

    lighting fixture

    Nos. 5

    11 Lighting transformer 100 KVA, 415/415, 3 phase, 50

    Hz dry type as per techincal specification

    Nos. 3

    12 Self supported aluminium ladder as per technical No. 1

    II) Fire Fighting Pump House:

    1 Lighting Panel

    a Lighting Panel (Indoor) Type ACP-1 as per

    technical specification

    No. 1

    2 Lighting fixtures and Receptacles including junction

    box, lightng wires & flexible conduit (if required) from

    junction box to lighting f ixture, mounting arrangement

    and other accessories/ materials etc. as required for

    complete installation and commissoning of lighting

    fixture/receptacle.

    a Lighting Fixture Type-FI as per technical specification Nos. 18

    b Lighting Fixture Type-BH as per technical specification Nos. 6

    c Lighting Fixture Type-SF5 as per technical

    specification

    Nos. 4

    d Lighting Fixture Type-FL as per technical specification Nos. 2

    e Lighting Fixture Type-IB as per technical specification Nos. 2

    f 5/15 A, 240V: Indoor Receptacle 3-pin type (Type RI) Nos. 4

    g 15A, 240V: Outdoor Receptacle 2 pole, 3-pin type

    (Type RO)

    Nos. 4

    h Lighting Poles Type A1 Nos. 4

    3 Switchboards

    Q-1 Aligarh

  • 8/4/2019 Price Schedule Q-Aligarh

    12/50

    a Modular switchboard with 4 nos. 5 Amp. Switches and

    1 no. 5/15 Amp. Receptacle

    Nos. 4

    b Modular switchboard with 6 nos. 5 Amp. Switches Nos. 2

    4 Exhaust fans Nos. 2

    5 Conduits & Wires

    a Heavy duty PVC conduits as of 20/25/32 mm size

    complete with all accessories for Point wiring for Light

    points , Fans power points 5/15 amps with 2.5 sq mm

    /4 sqmm/6.0 Sq mm copper for circuit wiring and 1.5sq mm copper earth wire PVC isulated in green

    colourt including wiring for submains i.e. wiring from

    Lighting Panel to Switch boards.

    Nos 59

    b Wiring from lighting panel to switch boards, from

    switchboards to junction boxes for Light Points,

    Submain, Power and Fan points with 2.5/4.0/6.0 Sq

    mm Copper wire as per technical specifications,

    complete in all respects.1.5 sq mm copper wire

    (Green) will be used for earthing inside counduits

    Nos 59

    III) Outdoor Lighting (Switchyard and Street Lighting)

    1 Lighting Panel

    a) Lighting Panel (Outdoor) Type ACP-2 as per

    technical specification

    Nos. 5

    b) Lighting Panel (Outdoor) Type ACP-3 as per

    technical s ecification

    Nos. 2

    c) Sub lighting panel (outdoor) Type SLP as per

    technical s ecification

    Nos. 6

    2 Lighting fixtures and Receptacles including junction

    box, lighting wires& flexible conduit (if required) from

    junction box to lighting f ixture, mounting arrangement

    and other accessories/materials etc. as required for

    complete installation and commissoning of lighting

    fixture.a Lingting Fixture Type-SF1 as per technical

    specification

    Nos. 40

    b Lingting Fixture Type-SF2 aa per technical

    specification

    Nos. 80

    Q-1 Aligarh

  • 8/4/2019 Price Schedule Q-Aligarh

    13/50

    c Lingting Fixture Type-SC as per technical specification Nos. 30

    d Lingting Fixture Type-SF5 as per technical

    specification

    Nos. 10

    e Lingting Fixture Type-BLD as per technical

    specification

    Nos. 48

    f 63A, 415V : Interlocked switch socket outdoor

    Receptacle (Type RP)

    Nos. 5

    3 Lighting Polesa Lighting Poles Type A1 Nos. 30

    b Lighting Poles Type E1 Nos. 12

    4 Cartwheel mounted aluminium ladder as per technical

    specification

    No. 1

    IV) Switchyard panel rooms

    a AC Panel Room(Lighting Fixture Type-FL as per tech.

    spec.-06 nos. per panel room)

    Nos. 11

    P 33kV HT Power Cable (XLPE type) along with all

    accessories & termination joint

    m 500

    Q 40 mm MS rod for Main Earthmat km 24

    R Steel Structures

    1 Lattice Structure for Towers & Beams MT 620

    2 Pipe Structure for Equipments MT 325

    S 6000 L.P.H. OIL FILTRATION PLANT1 6000 Liters/hour capacity ultra high vacuum, weather

    proof and mobile type oil purification and filtration plant

    Nos. 1

    T 0.2s ACCURACY CLASS STATIC ELECTRONIC

    TRIVECTOR ENERGY METERS ALONGWITH

    CUBICLE

    Sets 2

    Sub-Total (Part-A)

    Q-1 Aligarh

  • 8/4/2019 Price Schedule Q-Aligarh

    14/50

    Part-B: VENDER ASSESSED QUANTITIES

    A Erection Hardware for 400 KV I Type Layout

    Insulator strings, Disc Insulators, Hardware, conductor,

    Al tube, bus-bar materials, cable trays, Bay MB,

    clamps, spacers, connectors including equipment

    connectors, Junction box, earthwire, earthing material

    risers, auxiliary earthmat(excluding main earth mat)

    buried cable trenches/pipe equipment & lighting, allaccessories etc. as per technical specifications for the

    following:

    i Line bay Set 6

    ii Transformer bay Set 2

    iii Bus Reactor bay Set 1

    iv Line Reactor bay Set 1

    v Spare Bay of half dia Set 3

    vi Bus work (For two Diameters) Set 3

    B Erection Hardware for 220KV Double Main and

    transfer Scheme LayoutInsulator strings, Disc Insulators, Hardware, conductor,

    Al tube, bus-bar materials, cable trays, Bay MB,

    clamps, spacers, connectors including equipment

    connectors, Junction box, earthwire, earthing materialrisers, auxiliary earthmat(excluding main earth mat)

    buried cable trenches/pipe equipment & lighting, all

    accessories etc. as per technical specifications for the

    following:

    i Line bay Set 5

    ii Transformer bay Set 2

    iii Transfer Bus Coupler Bay Set 1

    iv Bus Coupler Bay Set 1

    v Bus work (For three Bays) Set 4

    C Air Conditioning system1.1 Air Conditioning system for switchyard Panel room (as

    per technical specifications )

    a) 400 kV (6 Nos.) LS 1

    b) 220 kV (5 Nos. ) LS 1

    Q-1 Aligarh

  • 8/4/2019 Price Schedule Q-Aligarh

    15/50

  • 8/4/2019 Price Schedule Q-Aligarh

    16/50

  • 8/4/2019 Price Schedule Q-Aligarh

    17/50

    5.0 Set of valves (1 no. of each type) Set 1

    4.0 Circuit Breakera) 420kV Circuit Breaker LS 1

    b) 245kV Circuit Breaker LS 1

    5.0 Isolator (Three phase)a) 420kV Isolator LS 1

    b) 245 kV isolator LS 1

    c) 72.5kV & 33kV Isolator LS 1

    6.0 Current Transformer (1 Ph.)a) 420kV CT(3000A 40kA with 120%) Nos. 2

    b) 245kV CT

    b(i) 1600A 40kA with 120% No. 1

    b(ii) 1600A 40kA with 150% No. 1

    c) 72.5 KV CT No. 1

    7.0 Capacitive Voltage Transformer (1 Ph.)a(i) 420kV CVT Nos. 2

    b) 245KV CVT Nos. 2

    c) 72.5 KV VT No. 1

    8.0 Surge Arrestor

    a) 390kV Surge Arrestor Nos. 2

    b) 216kV Surge Arrestor Nos. 2

    9.0 Fire Protection System LS 1

    10.0 Relay & Protection Panels LS 1

    11.0Sub-Station Automation System LS 1

    12.0 LT Switchgear LS 1

    13.0 PLCC LS 1

    14.0 Batteriesa) 220V Batteries LS 1

    b) 48V bateries LS 1

    15.0 Battery Chargera) 220V Battery Charger LS 1

    b) 48V Battery Cahrger LS 1

    Q-1 Aligarh

  • 8/4/2019 Price Schedule Q-Aligarh

    18/50

    16.0 DG Set LS 1

    17.0 Illumination System LS 1

    18.0 Erection Hardware Items LS 1

    19.0 400kV BPI Nos. 4

    20.0 220kV BPI Nos. 3

    21.0 6000 LPH Oil Filteration Plant

    a) Fi lter cartridge for processing used oil Nos. 100

    b) Edge type fil ters Nos. 100

    Sub-Total (Part-C)

    Grand Total( Part-A + Part-B+ Part-C) for

    400/220KV S/S ALIGARH

    Date:

    Place:

    Signature

    Name:

    Designation:

    Common Seal:

    Q-1 Aligarh Pag

  • 8/4/2019 Price Schedule Q-Aligarh

    19/50

    SCHEDULE- Q 1

    in Rupees )

    Any other

    12

    NA

    ties

    Q-1 Aligarh Page 1

  • 8/4/2019 Price Schedule Q-Aligarh

    20/50

    Q-1 Aligarh

  • 8/4/2019 Price Schedule Q-Aligarh

    21/50

    Q-1 Aligarh

  • 8/4/2019 Price Schedule Q-Aligarh

    22/50

    Q-1 Aligarh

  • 8/4/2019 Price Schedule Q-Aligarh

    23/50

    Q-1 Aligarh

  • 8/4/2019 Price Schedule Q-Aligarh

    24/50

    Q-1 Aligarh

  • 8/4/2019 Price Schedule Q-Aligarh

    25/50

    NA

    Q-1 Aligarh

  • 8/4/2019 Price Schedule Q-Aligarh

    26/50

    Q-1 Aligarh

  • 8/4/2019 Price Schedule Q-Aligarh

    27/50

    Q-1 Aligarh

  • 8/4/2019 Price Schedule Q-Aligarh

    28/50

    Q-1 Aligarh

  • 8/4/2019 Price Schedule Q-Aligarh

    29/50

    Q-1 Aligarh

  • 8/4/2019 Price Schedule Q-Aligarh

    30/50

    Q-1 Aligarh

  • 8/4/2019 Price Schedule Q-Aligarh

    31/50

    Q-1 Aligarh

  • 8/4/2019 Price Schedule Q-Aligarh

    32/50

    Q-1 Aligarh

  • 8/4/2019 Price Schedule Q-Aligarh

    33/50

    Q-1 Aligarh

  • 8/4/2019 Price Schedule Q-Aligarh

    34/50

    Q-1 Aligarh

  • 8/4/2019 Price Schedule Q-Aligarh

    35/50

    Q-1 Aligarh

  • 8/4/2019 Price Schedule Q-Aligarh

    36/50

    SCHEDULE- Q SCHEDULE OF QUANTITY AND PRICES FOR 400 KV S/S ALIGARH

    HANDLING, ERECTION, TESTING, COMMISSIONING, OPERATION AND MAINTENANCE CHARGES

    ( All Prices are in Rupee

    EQUIPMENT / ITEM Unit Qty. Unit Handling, Total Handling, Taxes if any

    Erection,Testing & Erection,Testing & % applicable

    Commissioning Charges Commissioning Charges amount

    1 2 3 4 5 6 7Part-A : UPPTCL ASSESSED QUANTITIES

    A. TRANSFORMERS & REACTORS

    1 AUTO TRANSFORMERS

    1.1 500 MVA , 400/220/33 kV Auto Transformer (3-

    Phase)

    Nos. 2

    2 LT TRANSFORMER2.1 630KVA , 33/0.415 KV Transformers (3-Phase) Nos. 2

    3 BUS REACTOR

    3.1 420 kV,63 MVAR BUS REACTOR (3-Phase) No. 1

    4 LINE REACTOR

    4.1 Dismantling & shifting of 420 kV, 50 MVAR Line

    Reactor(3-Phase) alongwith NGR & LA from 400

    kV S/S Muradnagar to 400 kV S/S Aligarh and their

    re-erection for 400kV S/S Aligarh-400 kV

    Muradnagar Line

    LS 1

    B. 400kV EQUIPMENT1 420kV Circuit Breakers (3-Phase) with support

    structure

    Sl No.

    (complete with all fittings, accessories,

    associated equipments etc. as specified in

    Technical Specifications)

    Q-2 Aligarh Page 36

  • 8/4/2019 Price Schedule Q-Aligarh

    37/50

    a. 3150A, 40KA with closing resistor Nos. 3

    b. 3150A, 40KA without closing resistor Nos. 12

    2 420 kV Current Transformer (1-Phase)

    a. 3000A, 40KA with 120% extended current rating Nos. 45

    3 420kV Isolator (3-phase) (Double Break)

    a. 3150A, 40KA, isolator with one E/S (Metalics only) Set 41

    b. Support Insulator for above Set 41

    c. 3150A, 40KA, isolator with two E/S (Metalics only) Set 2

    d. Support Insulator for above Set 2

    4 390 KV Surge Arrester (1-phase) Nos. 30

    5 420 kV Capacitive Voltage Transformer (1-

    hase) ( 4400 F )

    Nos. 24

    6 420 kV Bus Post Insulator (Except for wave

    traps)

    Nos. 72

    C. 220kV EQUIPMENT

    1 245 kV Circuit Breakers (3-Phase) with support

    structurea. 1600A, 40KA Nos. 8

    b. 2500A, 40KA Nos. 1

    2 245 kV Current Transformer (1-Phase)

    a. 1600A, 40KA with 120% extended current rating Nos. 24b. 1600A, 40KA with 150% extended current rating Nos. 3

    3 245 kV Capacitive Voltage Transformer (1-

    Phase) ( 4400 pF )

    Nos. 21

    4 245kV Isolator (3-phase)-Double Break

    a. 1600A, 40 KA, Isolator with one E/S(Metalics only) Set 8

    b. Support Insulator for above Set 8

    c. 1600A, 40 KA, Isolator with two E/S(Metalics only) Set 8

    d. Support Insulator for above Set 8

    e. 1600 A, 40KA, Tandem Isolator without

    E/S(Metalics only)

    Set 15

    f. Support Insulator for above Set 15

    g. 2500 A, 40KA, Isolator with 2 E/S(Metalics only) Set 2

    h. Support Insulator for above Set 2

    5 216 kV Surge Arrestors (1-phase) Nos. 21

    Q-2 Aligarh

  • 8/4/2019 Price Schedule Q-Aligarh

    38/50

  • 8/4/2019 Price Schedule Q-Aligarh

    39/50

    3 Bus Bar Protection Panel

    a. 220kV (Single bus bar protection) Nos. 1III) 72.5 kV1 Circuit Breaker Relay Panel

    a. Without Auto Reclose No. 1

    G Other/common Equipments

    1 Time synchronisation equipment Nos. 1

    H SUBSTATION AUTOMATION

    Complete Substation automation system for

    400/220kV substation as per technical specification

    1 400kV Bays (Main Bays + Tie Bays ) Nos. 15

    2 220kV Bays Nos. 9

    3 BCUs for controlling and monitoring of auxiliary syst Set 1

    I PLCC

    i) PLCC At 400 kV S/S Aligarh

    1 Line trapsa. 3150A, 400kV, 40KA,1.0 mH Line Trap Nos. 12b. BPI for above Nos. 36c. 1600A, 245kV, 40KA, 0.5mH Line Trap Nos. 10d. BPI for above Nos.

    302 PLCC Cabinets

    a Carrier equipment ( Speech+data+protection) Nos. 14

    b Carrier equipment ( Speech+data) Nos. 9

    3 Coupling device (2 LMU + 1 BT) Sets 11

    4 EPAX (24/8) with 24 nos telephones, cable etc Set 1

    5 4 wire telephone instrument( Along with telephone

    wiring )

    Nos. 1

    6 HF cable km 1

    ii) PLCC For Mainpuri (765 kV S/S) End

    1 PLCC Cabinets

    a Carrier equipment ( Speech+data+protection) Nos. 4 NA NA

    b Carrier equipment ( Speech+data) Nos. 2 NA NA

    2 Coupling device (2 LMU + 1 BT) Sets 2 NA NA

    3 HF cable km 0.5 NA NA

    Q-2 Aligarh

  • 8/4/2019 Price Schedule Q-Aligarh

    40/50

    iii) PLCC For 400 kV S/S Sikandrabad End

    1 PLCC Cabinets

    a Carrier equipment ( Speech+data+protection) Nos. 4 NA NA

    b Carrier equipment ( Speech+data) Nos. 2 NA NA

    2 Coupling device (2 LMU + 1 BT) Sets 2 NA NA

    3 HF cable km 0.5 NA NA

    iv) PLCC For 400 kV S/S Muradnagar End

    1 PLCC Cabinetsa Carrier equipment ( Speech+data+protection) Nos. 2 NA NA

    b Carrier equipment ( Speech+data) Nos. 1 NA NA

    iv) PLCC For 400 kV S/S Panki End

    1 PLCC Cabinets

    a Carrier equipment ( Speech+data+protection) Nos. 2 NA NA

    b Carrier equipment ( Speech+data) Nos. 1 NA NA

    v) PLCC For 220 kV S/S Atrauli End

    1 PLCC Cabinets

    a Carrier equipment ( Speech+data+protection) Nos. 2 NA NA

    b Carrier equipment ( Speech+data) Nos. 2 NA NA

    2 Coupling device (2 LMU + 1 BT) Sets 2 NA NA

    3 HF cable km 0.5 NA NA

    vi) PLCC For 220 kV S/S Khair End

    1 PLCC Cabinets

    a Carrier equipment ( Speech+data+protection) Nos. 1 NA NA

    b Carrier equipment ( Speech+data) Nos. 1 NA NA

    2 Coupling device (2 LMU + 1 BT) Sets 1 NA NA

    3 HF cable km 0.25 NA NA

    vii) PLCC For 220 kV S/S Hathras End

    1 PLCC Cabinets

    a Carrier equipment ( Speech+data+protection) Nos. 1 NA NA

    b Carrier equipment ( Speech+data) Nos. 1 NA NA

    2 Dismantling & shifting of PLCC cabinets from 220

    kV S/S Hathras to 400 kV S/S Aligarh and their re-

    erection for 400kV S/S Aligarh-220 kV Harduaganj

    Line

    LS 1

    Q-2 Aligarh

  • 8/4/2019 Price Schedule Q-Aligarh

    41/50

    J LT SWITCHGEAR

    1 415V Main switchboard Set 1

    2 415V ACDB Set 1

    3 415V MLDB Set 1

    4 415V Emergency LDB Set 1

    5 220V DCDB Sets 2

    6 48V DCDB Sets 2

    K BATTERIES/BATTERY CHARGER

    1 220V Battery

    a) 600 AH Sets 2

    2 48V Battery

    a) 800 AH Sets 2

    3 Float cum Boost Battery Charger

    a) 220V (60/60 Amp.) Sets 2

    b) 48V (80/80 Amp) Sets 2

    L DG Set along with Control panel (250 kVA ) Set 1

    M Fire Protection System

    1 For Switchyard Panel Room

    a. 4.5kg CO2 Type Portable Fire Extinguishers Nos. 11

    2 For Control Room Building and Fire Fighting PumpHouse

    a. Portable/Trolley/Wheel mounted extinguishers

    i. 9 litre water type Nos. 5

    ii. 4.5kg DCP type Nos. 5

    iii. 4.5kg CO2 type Nos. 5

    3 For LT Transformer

    a. 50 Litres Mechanical Foam Type

    Portable/Trolley/wheel mounted extinguishers

    Nos. 2

    N Air Conditioning System

    1 High Wall type split AC Unit of 2 TR Capacity Nos. 12

    O Illumination System

    I) Control Room Cum Administrative OfficeBuilding:

    Q-2 Aligarh

  • 8/4/2019 Price Schedule Q-Aligarh

    42/50

    1 Lighting Panel

    a Lighting Panel (Indoor) Type ACP-1 as per

    technical specification

    Nos. 3

    b Lighting Panel (Indoor) Type DCP as per technical

    specification

    No. 1

    2 Lighting fixtures and Receptacles (including

    accessories/ materials etc. as per requirement like

    junction box, cable/wires, flexible conduit (if

    required) from junction box to lighting fixture,mounting arrangements)

    a Lighting Fixture Type-FI as per technical

    specification

    Nos. 32

    b Lighting Fixture Type-DLR as per as per technical

    specification

    Nos. 3

    c Lighting Fixture Type-FF as per technical

    specification

    Nos. 63

    d Lighting Fixture Type-DSM as per as per technical

    specification

    Nos. 25

    e Lighting Fixture Type-IB as per technical

    specification

    Nos. 8

    f Lighting Fixture Type-BH as per technical

    specification

    Nos. 18

    g Lighting Fixture Type-SL as per technical

    specification

    Nos. 6

    h Lighting Fixture Type-TL as per technical

    specification

    Nos. 5

    i 5/15 A, 240V: Indoor Receptacle 3-pin type (Type

    RI)

    Nos. 40

    j 15A, 240V: Outdoor Receptacle 2 pole, 3-pin type

    (Type RO)

    Nos. 10

    k 63A, 415V : Interlocked switch socket outdoor

    Receptacle (Type RP)

    No. 1

    3 Switchboards

    a Modular switchboard with 4 nos. 5 Amp. Switches

    and 1 no. 5/15 Amp. Receptacle

    Nos. 20

    b Modular switchboard with 6 nos. 5 Amp. Switches Nos. 20

    c Modular switchboard with 2 nos. 5 Amp. Switches Nos. 10

    Q-2 Aligarh

  • 8/4/2019 Price Schedule Q-Aligarh

    43/50

    d Adiitional 2 modules and Eletronic Step Regulator

    to be mounted in the above switch boards

    Nos. 20

    4 Ceiling Fans

    a 1400mm sweep with electronic Step regulator Nos. 20

    5 Exhaust fans Nos. 6

    6 Wall mounted fans 400 mm sweep Nos. 6

    7 Conduits & Wires

    a) Heavy duty PVC conduits as of 20/25/32 mm sizecomplete with all accessories for Point wiring for

    Light points , Fans power points 5/15 amps with 2.5

    sq mm /4 sqmm/6.0 Sq mm copper for circuit

    wiring and 1.5 sq mm copper earth wire PVC

    isulated in green colourt including wiring for

    submains i.e. wiring from Lighting Panel to Switch

    boards.

    Nos 278

    b) Wiring from lighting panel to switch boards, from

    switchboards to junction boxes for Light Points,

    Submain, Power and Fan points with 2.5/4.0/6.0 Sq

    mm Copper wire as per technical specifications,

    complete in all respects.1.5 sq mm copper wire

    (Green) will be used for earthing inside counduits

    Nos 256

    8 Wire for Telephone

    a) Telephone cables screenede with annealed tin

    conductor and PVC insulation of 20 pair , 10 pair

    and 2pair as required for wiring requirement of 24/8

    line exchange

    LS 1

    b) Telehone Junction boxes/tag blocks to suit

    requirement of 24/8 telephone connections within

    the control room building , adminstrative block and

    fire fighting buliding

    LS 1

    c) Telephone sockets

    1 Single socket outlet comprising RJ-11 Socket Nos. 20

    2 Dual socket outlet comprising RJ-45 Socket Nos. 24

    9 Occupany sensors and other accessories as

    required for control of lighting in Control Room,

    ACDB & DCDB room, Battery room and Electrical

    Test Lab

    Set 7

    Q-2 Aligarh

  • 8/4/2019 Price Schedule Q-Aligarh

    44/50

    10 Junction Boxes with 4 nos. of terminal blocks for

    indoor lighting excluding junction box supplied

    alongwith lighting fixture

    Nos. 5

    11 Lighting transformer 100 KVA, 415/415, 3 phase, 50

    Hz dry type as per techincal specification

    Nos. 3

    12 Self supported aluminium ladder as per technical

    specification

    No. 1 NA NA

    II) Fire Fighting Pump House:1 Lighting Panel

    a Lighting Panel (Indoor) Type ACP-1 as per

    technical specification

    No. 1

    2 Lighting fixtures and Receptacles including junction

    box, lightng wires & flexible conduit (if required)

    from junction box to lighting fixture, mounting

    arrangement and other accessories/ materials etc.

    as required for complete installation and

    commissoning of lighting fixture/receptacle.

    a Lighting Fixture Type-FI as per technical

    specification

    Nos. 18

    b Lighting Fixture Type-BH as per technical

    specification

    Nos. 6

    c Lighting Fixture Type-SF5 as per technicalspecification

    Nos. 4

    d Lighting Fixture Type-FL as per technical

    specification

    Nos. 2

    e Lighting Fixture Type-IB as per technical

    specification

    Nos. 2

    f 5/15 A, 240V: Indoor Receptacle 3-pin type (Type

    RI)

    Nos. 4

    g 15A, 240V: Outdoor Receptacle 2 pole, 3-pin type

    (Type RO)

    Nos. 4

    h Lighting Poles Type A1 Nos. 4

    3 Switchboards

    a Modular switchboard with 4 nos. 5 Amp. Switches

    and 1 no. 5/15 Amp. Receptacle

    Nos. 4

    b Modular switchboard with 6 nos. 5 Amp. Switches Nos. 2

    Q-2 Aligarh

  • 8/4/2019 Price Schedule Q-Aligarh

    45/50

    4 Exhaust fans Nos. 2

    5 Conduits & Wires

    a Heavy duty PVC conduits as of 20/25/32 mm size

    complete with all accessories for Point wiring for

    Light points , Fans power points 5/15 amps with 2.5

    sq mm /4 sqmm/6.0 Sq mm copper for circuit

    wiring and 1.5 sq mm copper earth wire PVC

    isulated in green colourt including wiring for

    submains i.e. wiring from Lighting Panel to Switchboards.

    Nos 59

    b Wiring from lighting panel to switch boards, from

    switchboards to junction boxes for Light Points,

    Submain, Power and Fan points with 2.5/4.0/6.0 Sq

    mm Copper wire as per technical specifications,

    complete in all respects.1.5 sq mm copper wire

    (Green) will be used for earthing inside counduits

    Nos 59

    III) Outdoor Lighting (Switchyard and Street

    Lighting)1 Lighting Panel

    a) Lighting Panel (Outdoor) Type ACP-2 as per

    technical specification

    Nos. 5

    b) Lighting Panel (Outdoor) Type ACP-3 as per

    technical specification

    Nos. 2

    c) Sub lighting panel (outdoor) Type SLP as per

    technical s ecification

    Nos. 6

    2 Lighting fixtures and Receptacles including

    junction box, lighting wires& flexible conduit (if

    required) from junction box to lighting fixture,

    mounting arrangement and other

    accessories/materials etc. as required for complete

    installation and commissoning of lighting fixture.

    a Lingting Fixture Type-SF1 as per technical

    specification

    Nos. 40

    b Lingting Fixture Type-SF2 aa per technical

    specification

    Nos. 80

    c Lingting Fixture Type-SC as per technical

    specification

    Nos. 30

    d Lingting Fixture Type-SF5 as per technical

    specification

    Nos. 10

    Q-2 Aligarh

  • 8/4/2019 Price Schedule Q-Aligarh

    46/50

    e Lingting Fixture Type-BLD as per technical

    specification

    Nos. 48

    f 63A, 415V : Interlocked switch socket outdoor

    Receptacle (Type RP)

    Nos. 5

    3 Lighting Poles

    a Lighting Poles Type A1 Nos. 30

    b Lighting Poles Type E1 Nos. 12

    4 Cartwheel mounted aluminium ladder as per

    technical specification

    No. 1 NA NA

    IV) Switchyard panel rooms

    a AC Panel Room(Lighting Fixture Type-FL as per

    tech. spec.-06 nos. per panel room)

    Nos. 11

    P 33kV HT Power Cable (XLPE type) along with all

    accessories & termination joint

    m 500

    Q 40 mm MS rod for Main Earthmat km 24

    R Steel Structures

    1 Lattice Structure for Towers & Beams MT 620

    2 Pipe Structure for Equipments MT 325

    S 6000 L.P.H. OIL FILTRATION PLANT1 6000 Liters/hour capacity ultra high vacuum,

    weather proof and mobile type oil purification and

    filtration plant

    Nos. 1

    T 0.2s ACCURACY CLASS STATIC ELECTRONIC

    TRIVECTOR ENERGY METERS ALONGWITH

    CUBICLE

    Sets 2

    Sub-Total (Part-A)

    Q-2 Aligarh

  • 8/4/2019 Price Schedule Q-Aligarh

    47/50

    Part-B: VENDER ASSESSED QUANTITIES

    A Erection Hardware for 400 KV I Type LayoutInsulator strings, Disc Insulators, Hardware,

    conductor, Al tube, bus-bar materials, cable trays,

    Bay MB, clamps, spacers, connectors including

    equipment connectors, Junction box, earthwire,

    earthing material risers, auxiliary

    earthmat(excluding main earth mat) buried cabletrenches/pipe equipment & lighting, all accessories

    etc. as per technical specifications for the following:

    i Line bay Set 6

    ii Transformer bay Set 2

    iii Bus Reactor bay Set 1

    iv Line Reactor bay Set 1

    v Spare Bay of half dia Set 3

    vi Bus work (For two Diameters) Set 3

    B Erection Hardware for 220KV Double Main and

    transfer Scheme LayoutInsulator strings, Disc Insulators, Hardware,

    conductor, Al tube, bus-bar materials, cable trays,

    Bay MB, clamps, spacers, connectors including

    equipment connectors, Junction box, earthwire,

    earthing material risers, auxiliary

    earthmat(excluding main earth mat) buried cable

    trenches/pipe equipment & lighting, all accessories

    etc. as per technical specifications for the following:

    i Line bay Set 5

    ii Transformer bay Set 2

    iii Transfer Bus Coupler Bay Set 1

    iv Bus Coupler Bay Set 1

    v Bus work (For three Bays) Set 3

    C Air Conditioning system

    1.1 Air Conditioning system for switchyard Panel room

    (as per technical specifications )

    a) 400 kV (6 Nos.) LS 1

    b) 220 kV (5 Nos. ) LS 1

    Q-2 Aligarh

  • 8/4/2019 Price Schedule Q-Aligarh

    48/50

    D Fire Protection System

    1.1 Pumping arrangement for HVW system & hydrant

    system, complete with all piping, valves,

    fittings,panels, batteries, chargers, etc. etc. inside

    pump house as per technical specification

    Set 1

    1.2 Hydrant system, complete U/G piping and

    accessories etc. outside the Pump House as per

    technical specification

    Set 1

    1.3 Fire detection and alarm system Set 1

    1.4 HVW spray system, Hydrant system and complete

    U/G & O/G piping and accessories etc. for

    Transformer / Reactor as per specification:

    a) Autotransformer Nos. 2

    b) Bus Reactor Nos. 1

    c) Line Reactor Nos. 1

    E Cables along with associated clamps, glands,

    lugs etc.1.1 Power Cables (XLPE) (1.1 kV grade) LS 1

    (a) 1Cx630 sq. mm (XLPE)

    (b) 3.5Cx300 sq.mm (XLPE)

    1.2 Power Cables(PVC) (1.1 kV grade) LS 1

    (a) 1Cx150sq.mm

    (b) 3.5Cx70 sq.mm

    (c) 3.5Cx35 sq.mm

    (d) 4Cx16 sq.mm

    (e) 4Cx6 sq.mm

    (f) 2Cx16 sq.mm

    (g) 2Cx6 sq.mm

    Q-2 Aligarh

  • 8/4/2019 Price Schedule Q-Aligarh

    49/50

    1.3 Control Cable (PVC) (1.1 kV grade) LS 1(a) 2Cx2.5 sq.mm

    (b) 3Cx2.5 sq.mm

    (c) 5Cx2.5 sq.mm

    (d) 7Cx2.5 sq.mm

    (e) 10Cx2.5 sq.mm

    (f) 14Cx2.5 sq.mm

    (g) 19Cx2.5 sq.mm

    (h) 27Cx2.5 sq.mmSub-Total (Part-B)

    (Part-C)

    A. Operation & Maintenance of Substation for Two

    Years

    LS 1

    Grand Total( Part-A + Part-B+ Part-C) for

    400/220KV S/S ALIGARH

    Date:

    Place:

    Signature

    Name:

    Designation:

    Common Seal:

    Q-2 Aligarh

  • 8/4/2019 Price Schedule Q-Aligarh

    50/50

    Lumpsum / Summary Price Schedule

    For 400/220KV S/S ALIGARH

    SI No. Description Amount (in Rs.)1 Total Equipment & materials Ex- works price Q-1

    2 Total freight and insurance charges

    3 Total handling, Erection, testing , commissioning, Operation

    & maintenance charges. Q-24 Total charges for civil works including supply of materials.

    5 Total bid price excluding taxes & duties.

    6 Total excise duty.

    7 Total central sales tax/Trade tax

    8 Total other taxes/duties/levies.

    9 Total lump sum bid prices.

    Date:Place:

    SignatureName:

    Designation:

    Common Seal: