PRIMERGY RX100 S5 Server Operating manual

Edition June 2009

Page 2: PRIMERGY RX100 S5 - Fujitsumanuals.ts.fujitsu.com/file/3934/rx100s5-ba-en.pdf · RX100 S5 Operating manual 7 1 Preface The PRIMERGY RX100 S5 server is an Intel-based server for small

Comments… Suggestions… Corrections…The User Documentation Department would like toknow your opinion of this manual. Your feedback helpsus optimize our documentation to suit your individual needs.

Feel free to send us your comments by e-mail to [email protected].

Certified documentation according to DIN EN ISO 9001:2000To ensure a consistently high quality standard anduser-friendliness, this documentation was created tomeet the regulations of a quality management system which complies with the requirements of the standardDIN EN ISO 9001:2000.

cognitas. Gesellschaft für Technik-Dokumentation mbHwww.cognitas.de

Copyright and TrademarksCopyright © 2009 FujitsuTechnology Solutions GmbH.

All rights reserved.

Delivery subject to availability. The right to technical modification is reserved.

All hardware and software names used are trade names and/or trademarks of their respective manufacturers.

Page 3: PRIMERGY RX100 S5 - Fujitsumanuals.ts.fujitsu.com/file/3934/rx100s5-ba-en.pdf · RX100 S5 Operating manual 7 1 Preface The PRIMERGY RX100 S5 server is an Intel-based server for small

RX100 S5 Operating manual

Contents

1 Preface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7

1.1 Concept and target groups for this manual . . . . . . . . . . 7

1.2 Documentation overview . . . . . . . . . . . . . . . . . . . . 8

1.3 Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10

1.4 Notational conventions . . . . . . . . . . . . . . . . . . . . 19

1.5 Technical data . . . . . . . . . . . . . . . . . . . . . . . . . 20

2 Installation steps, overview . . . . . . . . . . . . . . . . . . 23

3 Important information . . . . . . . . . . . . . . . . . . . . . 25

3.1 Safety instructions . . . . . . . . . . . . . . . . . . . . . . . 25

3.2 CE conformity . . . . . . . . . . . . . . . . . . . . . . . . . 32

3.3 FCC Class A Compliance Statement . . . . . . . . . . . . . 33

3.4 Transporting the server . . . . . . . . . . . . . . . . . . . . 34

3.5 Rack installation instructions . . . . . . . . . . . . . . . . . 35

3.6 Environmental protection . . . . . . . . . . . . . . . . . . . 36

4 Hardware installation . . . . . . . . . . . . . . . . . . . . . . 39

4.1 Unpacking the server . . . . . . . . . . . . . . . . . . . . . 40

4.2 Installing/removing the server in/from the rack . . . . . . . 414.2.1 Rack requirements . . . . . . . . . . . . . . . . . . . . . . . 424.2.2 Installation in PRIMECENTER/DataCenter rack . . . . . . . . . 454.2.3 Installation in 3rd party racks . . . . . . . . . . . . . . . . . . 484.2.4 Inserting the server . . . . . . . . . . . . . . . . . . . . . . . 49

4.3 Connecting devices to the server . . . . . . . . . . . . . . . 514.3.1 Connecting the monitor . . . . . . . . . . . . . . . . . . . . . 52

4.4 Connecting the server to the mains . . . . . . . . . . . . . . 53

Page 4: PRIMERGY RX100 S5 - Fujitsumanuals.ts.fujitsu.com/file/3934/rx100s5-ba-en.pdf · RX100 S5 Operating manual 7 1 Preface The PRIMERGY RX100 S5 server is an Intel-based server for small

Operating manual RX100 S5

Contents

4.5 Instructions for connecting/disconnecting cables . . . . . . 54

5 Starting up and operation . . . . . . . . . . . . . . . . . . . . 55

5.1 Controls and indicators . . . . . . . . . . . . . . . . . . . . . 555.1.1 Front of server . . . . . . . . . . . . . . . . . . . . . . . . . . 555.1.1.1 Controls . . . . . . . . . . . . . . . . . . . . . . . . . . . . 565.1.1.2 Indicators on the control panel . . . . . . . . . . . . . . . . 575.1.1.3 Indicators on the accessible drives/components . . . . . . . 595.1.2 Rear of server . . . . . . . . . . . . . . . . . . . . . . . . . . . 61

5.2 Switching the server on and off . . . . . . . . . . . . . . . . 65

5.3 Configuring the server . . . . . . . . . . . . . . . . . . . . . 675.3.1 Hard disk drive write cache . . . . . . . . . . . . . . . . . . . . 675.3.2 Configuring the onboard SATA controller . . . . . . . . . . . . . 685.3.3 Configuring the onboard SAS controller with “Integrated

Mirroring Enhanced” . . . . . . . . . . . . . . . . . . . . . . . 685.3.4 Configuration with ServerStart . . . . . . . . . . . . . . . . . . 695.3.5 Configuration without ServerStart . . . . . . . . . . . . . . . . 70

5.4 Cleaning the server . . . . . . . . . . . . . . . . . . . . . . . 70

6 Property and data protection . . . . . . . . . . . . . . . . . . 71

6.1 BIOS Setup security functions . . . . . . . . . . . . . . . . . 71

7 Troubleshooting and tips . . . . . . . . . . . . . . . . . . . . 73

7.1 Power-on indicator remains unlit . . . . . . . . . . . . . . . . 73

7.2 Server switches itself off . . . . . . . . . . . . . . . . . . . . 74

7.3 Screen remains blank . . . . . . . . . . . . . . . . . . . . . . 74

7.4 Flickering stripes on monitor screen . . . . . . . . . . . . . 75

7.5 No screen display or display drifts . . . . . . . . . . . . . . . 75

7.6 No mouse pointer displayed on screen . . . . . . . . . . . . 75

7.7 Incorrect date and time . . . . . . . . . . . . . . . . . . . . . 76

7.8 System will not boot . . . . . . . . . . . . . . . . . . . . . . . 76

7.9 Error message on screen . . . . . . . . . . . . . . . . . . . . 76

Page 5: PRIMERGY RX100 S5 - Fujitsumanuals.ts.fujitsu.com/file/3934/rx100s5-ba-en.pdf · RX100 S5 Operating manual 7 1 Preface The PRIMERGY RX100 S5 server is an Intel-based server for small

RX100 S5 Operating manual

Contents

8 CSS components . . . . . . . . . . . . . . . . . . . . . . . . 77

8.1 Hot-plug HDD modules . . . . . . . . . . . . . . . . . . . . 788.1.1 HDD module and dummy module . . . . . . . . . . . . . . . . 798.1.2 Handling hard disk drives and HDD modules . . . . . . . . . . 808.1.3 Removing/installing the dummy module . . . . . . . . . . . . . 818.1.4 Installing the HDD module . . . . . . . . . . . . . . . . . . . . 828.1.5 Removing the HDD module . . . . . . . . . . . . . . . . . . . 85

8.2 Replacement of non-hot-plug components . . . . . . . . . 878.2.1 Opening the server and identifying the defective CSS

component . . . . . . . . . . . . . . . . . . . . . . . . . . . . 878.2.2 Replacing a memory module . . . . . . . . . . . . . . . . . . 898.2.2.1 Removing a defective memory module . . . . . . . . . . . 898.2.2.2 Installing a new memory module . . . . . . . . . . . . . . . 908.2.3 Replacing a system fan . . . . . . . . . . . . . . . . . . . . . 918.2.4 Replacing an expansion card . . . . . . . . . . . . . . . . . . 958.2.4.1 Removing a riser module . . . . . . . . . . . . . . . . . . 958.2.4.2 Removing a defective expansion card . . . . . . . . . . . . 968.2.4.3 Installing a new expansion card . . . . . . . . . . . . . . . 978.2.4.4 Installing a riser module . . . . . . . . . . . . . . . . . . . 988.2.5 Assembling the server . . . . . . . . . . . . . . . . . . . . . . 100

Index . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 101

Page 6: PRIMERGY RX100 S5 - Fujitsumanuals.ts.fujitsu.com/file/3934/rx100s5-ba-en.pdf · RX100 S5 Operating manual 7 1 Preface The PRIMERGY RX100 S5 server is an Intel-based server for small
Page 7: PRIMERGY RX100 S5 - Fujitsumanuals.ts.fujitsu.com/file/3934/rx100s5-ba-en.pdf · RX100 S5 Operating manual 7 1 Preface The PRIMERGY RX100 S5 server is an Intel-based server for small

RX100 S5 Operating manual 7

1 PrefaceThe PRIMERGY RX100 S5 server is an Intel-based server for small and medium-sized networks and can be used in the rack systems made by Fujitsu Technology Solutions GmbH and in current standard rack systems made by various other manufacturers.

Thanks to its highly developed hardware and software components, the PRIMERGY RX100 S5 server offers a high level of data security and availability. These include the ServerView server management software, Prefailure Detection and Analysis (PDA) and Automatic Server Reconfiguration and Restart (ASR&R).

Security functions in the BIOS Setup and on the system board protect the data on the server against manipulation. Additional security is provided by the lockable rack door.

The server occupies 1 height unit in the rack.

1.1 Concept and target groups for this manual

This operating manual describes how to install, set up and operate your server.

This operating manual is intended for those responsible for installing the hardware and ensuring that the system runs smoothly. It contains all the infor-mation you need to put your PRIMERGY RX100 S5 server blade into operation.

To understand the various expansion options, you will need to be familiar with the fields of hardware and data transmission and you will require a basic knowledge of the underlying operating system.

Page 8: PRIMERGY RX100 S5 - Fujitsumanuals.ts.fujitsu.com/file/3934/rx100s5-ba-en.pdf · RX100 S5 Operating manual 7 1 Preface The PRIMERGY RX100 S5 server is an Intel-based server for small

8 Operating manual RX100 S5

Documentation overview Preface

1.2 Documentation overview

More information on your PRIMERGY RX100 S5 can be found in the following documents:

– “Quick Start Hardware - PRIMERGY RX100 S5” leaflet (only included as a printed copy)

– “Quick Start Software - Quick Installation Guide” leaflet (only included as a printed copy)

– “Safety notes and other important information” manual

– “Warranty” manual

– “Customer Self Service (CSS)” manual

– “Ergonomics” manual

– “Returning used devices” manual

– “Helpdesk” leaflet

– Technical manual for the system board D2542

– “PRIMERGY RX100 S5 Server Operating Manual”

– “PRIMERGY RX100 S5 Server Options Guide”

– “BIOS Setup V4.06 / FirstBIOS Desktop Pro V5.0 /TrustedCoreTM V6.0” manual

– “Embedded MegaRAID Software User’s Guide”

– “SAS/SATA Controller MegaRAID 1064 / 1068 / 1078 Installation Guide”

– “ServerView RAID User's Guide”

Page 9: PRIMERGY RX100 S5 - Fujitsumanuals.ts.fujitsu.com/file/3934/rx100s5-ba-en.pdf · RX100 S5 Operating manual 7 1 Preface The PRIMERGY RX100 S5 server is an Intel-based server for small

RX100 S5 Operating manual 9

Preface Documentation overview

I PRIMERGY manuals are available in PDF format on the ServerBooks DVD. The ServerBooks DVD is part of the ServerStart Suite supplied with every server.

The PDF files of the manuals can also be downloaded free of charge from the Internet. The overview page showing the online documentation available on the Internet can be found using the URL: http://manuals.ts.fujitsu.com. The PRIMERGY server documentation can be accessed using the Industry standard servers navigation option.

Further sources of information:

– Manual for the monitor– Documentation for boards and drives– Documentation for your operating system– Information files on your operating system

Page 10: PRIMERGY RX100 S5 - Fujitsumanuals.ts.fujitsu.com/file/3934/rx100s5-ba-en.pdf · RX100 S5 Operating manual 7 1 Preface The PRIMERGY RX100 S5 server is an Intel-based server for small

10 Operating manual RX100 S5

Features Preface

1.3 Features

Customer Self Service (CSS)

The Fujitsu Technology Solutions Customer Self Service (CSS) concept enables you to identify and replace the affected component yourself in the case of certain error scenarios.

In the CSS concept, you can replace the following components yourself in the event of an error:

– Hot-plug hard disk drives

– Memory modules

– System fans

– Expansion cards

For information on replacing these components, see chapter “CSS compo-nents” on page 77.

CSS indicators on the control panel and on the back of the PRIMERGY server provide you with information if a CSS event arises (for more information on the behavior of these indicators, see chapter “Starting up and operation” on page 55 and the “Customer Self Service (CSS)” manual on the ServerBooks DVD).

You can also fit your server with a ServerView Local Service Panel, which enables you to identify the type of component affected by the error directly on the server (for more information , see the “Customer Self Service (CSS)” manual on the ServerBooks DVD).

In addition, CSS errors are displayed in ServerView S2, the server management software from Fujitsu Technology Solutions

In the event of errors, ServerView S2 refers you directly to the affected component and its order information in the Illustrated Spares catalog of the server in question.

Page 11: PRIMERGY RX100 S5 - Fujitsumanuals.ts.fujitsu.com/file/3934/rx100s5-ba-en.pdf · RX100 S5 Operating manual 7 1 Preface The PRIMERGY RX100 S5 server is an Intel-based server for small

RX100 S5 Operating manual 11

Preface Features

System board

The features of the system board are described in the technical manual for the system board D2542 for the hardware and in the “BIOS Setup” for the firmware.

TPM (optional)

The system board is optional equipped with a TPM (Trusted Platform Module) by the manufacturer. This module enables programs from third party manufac-turers to store key information (e.g. drive encryption using Windows Bitlocker Drive Encryption).

The TPM is activated via the BIOS system (for more information, refer to the Fujitsu Technology Solutions BIOS manual).

V CAUTION!

– When using the TPM, note the program descriptions provided by the third party manufacturers.

– You must also create a backup of the TPM content. To do this, follow the third party manufacturer's instructions. Without this backup, if the TPM or the system board is faulty you will not be able to access your data.

– If a failure occurs, please inform your service about the TPM activation before it takes any action, and be prepared to provide them with your backup copies of the TPM content.

Page 12: PRIMERGY RX100 S5 - Fujitsumanuals.ts.fujitsu.com/file/3934/rx100s5-ba-en.pdf · RX100 S5 Operating manual 7 1 Preface The PRIMERGY RX100 S5 server is an Intel-based server for small

12 Operating manual RX100 S5

Features Preface

Hard disk drives

Two basic versions of the server are available, fitted with either SATA or SAS hard disk drives.

– Server with SATA hard disk drives:

With the standard design, the server has a drive cage in which up to two SATA hard disk drives with an EasyChange installation frame and a maximum height of 1 inch are fitted. There is a wire connection to the controller. Defective hard disk drives cannot be replaced during operation.

The server can optionally be upgraded with a SATA backplane. Up to two SATA HDD modules can then be used in the drive cage. Each HDD module can accommodate a SATA hard disk drive with a maximum height of 1 inch. The module is connected to the SATA backplane wirelessly. This allows HDD modules to be plugged in and pulled out easily. If the server has a corre-sponding RAID configuration, defective HDD modules can also be replaced during operation.

– Server with SAS hard disk drives:

Up to two SAS HDD modules can be used in the drive cage. Each HDD module can accommodate a SAS hard disk drive with a maximum height of 1 inch. The modules are connected to the SAS backplane wirelessly. This allows HDD modules to be plugged in or pulled out easily. If the server has a corresponding RAID configuration, defective HDD modules can also be replaced during operation.

Page 13: PRIMERGY RX100 S5 - Fujitsumanuals.ts.fujitsu.com/file/3934/rx100s5-ba-en.pdf · RX100 S5 Operating manual 7 1 Preface The PRIMERGY RX100 S5 server is an Intel-based server for small

RX100 S5 Operating manual 13

Preface Features

Onboard SATA controller

A SATA controller is fitted to operate the two SATA hard drives. The LSI Embedded MegaRAID software supports RAID levels 0 and 1.

I The controller has its own configuration utility. More detailed information may be found in the “Embedded MegaRAID Software User’s Guide” manual (on the ServerBooks DVD under “Controllers”).

Onboard SAS controller with Integrated Mirroring Enhanced functionality

A SAS controller with “Integrated Mirroring Enhanced” (IME) functionality is fitted to operate the two SAS hard drives. IME supports RAID level 0 and 1 for the internal hard disk drives.

I The controller makes a separate utility available for IME configuration. For further information, refer to the “SAS/SATA Controller MegaRAID 1064 / 1068 / 1078 Installation Guide” on the ServerBooks DVD (select “Controllers” from the menu).

Accessible drives/components

A number of mounting locations are available:

– An installation slot for a ServerView Local Service Panel (optional)– An installation slot for a slimline DVD drive (option)

The accessible drives/components integrated in this locations cannot be replaced during operation.

Power supply

The server has a built-in power supply unit, which automatically sets itself to a mains voltage in the range 100 V - 127 V or 200 V - 240 V.

Page 14: PRIMERGY RX100 S5 - Fujitsumanuals.ts.fujitsu.com/file/3934/rx100s5-ba-en.pdf · RX100 S5 Operating manual 7 1 Preface The PRIMERGY RX100 S5 server is an Intel-based server for small

14 Operating manual RX100 S5

Features Preface

High level of availability and data security

When memory data is accessed, 1-bit errors in the main memory are identified and automatically corrected with the ECC (Error Correcting Code) method.

ASR&R (Automatic Server Reconfiguration and Restart) restarts the system in the event of an error and automatically "hides" the defective system compo-nents.

The PDA (Prefailure Detection and Analysis) technology from Fujitsu Technology Solutions analyzes and monitors all components that are critical for system reliability.

The onboard RAID controller supports the RAID levels 0 and 1, thus increasing system availability and reliability.

The hot-plug HDD modules provide additional availability.

Page 15: PRIMERGY RX100 S5 - Fujitsumanuals.ts.fujitsu.com/file/3934/rx100s5-ba-en.pdf · RX100 S5 Operating manual 7 1 Preface The PRIMERGY RX100 S5 server is an Intel-based server for small

RX100 S5 Operating manual 15

Preface Features

iRMC S2 with integrated service LAN port

I The features of the iRMC S2 Advanced Video Redirection and Remote Storage are available as an option.

The iRMC S2 (integrated Remote Management Controller) is a BMC with integrated service LAN port and expanded functionality that was previously only available with additional plug-in cards. In this way, the iRMC S2 enables complete control of PRIMERGY servers, regardless of system status, and thus particularly the control of PRIMERGY servers that are in the “out-of-band” system status.

Major functions supported by the iRMC S2 include the following:

● Browser access via iRMC's own Web server

● Secure communication (SSH, SSL)

● Power Management for the managed server (depending on its system status)

● Connecting virtual drives as remote storage

● Text-based and graphic console bypass (Advanced Video Redirection)

● Command Line Interface (CLP)

● Simple, interactive or script-based iRMC S2 configuration

● Customer Self Service (CSS)

● iRMC-s own user management

● Multi-computer, global iRMC user administration using an LDAP Directory Service

● Automatic network configuration via DNS / DHCP

● Power supply of the iRMC S2 via the system standby supply

● Full-coverage alarm management

● System Event Log (SEL) reading and processing

More information about the iRMC S2 can be found in the “iRMC S2 - integrated Remote Management Controller” manual.

Page 16: PRIMERGY RX100 S5 - Fujitsumanuals.ts.fujitsu.com/file/3934/rx100s5-ba-en.pdf · RX100 S5 Operating manual 7 1 Preface The PRIMERGY RX100 S5 server is an Intel-based server for small

16 Operating manual RX100 S5

Features Preface

Server management

Server management is implemented using the supplied ServerView software in conjunction with PDA (Prefailure Detection and Analysis) technology from Fujitsu. PDA reports the threat of a system error or overload at an early stage, allowing preventive measures to be taken.

ServerView enables the management of all PRIMERGY servers in the network via a central console. ServerView supports the following functions:

● Round-the-clock monitoring, regardless of server status

● High-performance, graphical console bypass (AVR) protected by HTTPS/SSL (128-bit)

● Remote storage via USB

● Remote power on (Wake On LAN)

● Temperature monitoring of the CPU, the system board and the surrounding area

● Monitoring of PCI bus loading

● Detailed status and error reports for bus systems, processors and main memory

● Watchdog timer for Automatic Server Reconfiguration and Restart (ASR&R) in the event of failure of memory modules or processors

● Power monitoring

● End-of-life monitoring of fans with prompt notification before failure

● Watchdog timer for monitoring the operating system and applications with ASR&R

Further information on the ServerView server management is provided in the associated documentation.

ServerStart

You can configure the PRIMERGY server quickly and precisely with the ServerStart software provided. User-guided menus are available for installing the server operating system (for further details see section “Configuring the server” on page 67).

Page 17: PRIMERGY RX100 S5 - Fujitsumanuals.ts.fujitsu.com/file/3934/rx100s5-ba-en.pdf · RX100 S5 Operating manual 7 1 Preface The PRIMERGY RX100 S5 server is an Intel-based server for small

RX100 S5 Operating manual 17

Preface Features

Service and support

PRIMERGY servers are service-friendly and modular, enabling quick and easy maintenance.

The handles and locks (touch point) on the various hot pluggable components are colored green to ensure simple and immediate recognition.

In order to prevent the components from being damaged by incorrect handling when they are being installed and removed, the areas of all components that can be touched without damaging them are also marked green.

PRIMERGY diagnostic LEDs fitted on the system board show which component on the board (memory module, CPU, fan, expansion cards) is not functioning properly.

The Flash EPROM program supplied with the Fujitsu Technology Solutionsutilities supports a fast BIOS update.

With the iRMC S2 (integrated Remote Management Controller) on the system board and the optional remote testing and diagnostic system ServerView Remote Management, the PRIMERGY RX100 S5 server can also be maintained and serviced remotely. This enables remote diagnosis for system analysis, remote configuration and remote restart should the operating system or hardware fail.

Page 18: PRIMERGY RX100 S5 - Fujitsumanuals.ts.fujitsu.com/file/3934/rx100s5-ba-en.pdf · RX100 S5 Operating manual 7 1 Preface The PRIMERGY RX100 S5 server is an Intel-based server for small

18 Operating manual RX100 S5

Features Preface

ServerView Remote Management

ServerView Remote Management is the remote management solution from Fujitsu Technology Solutions for PRIMERGY servers. ServerView Remote Management and the relevant hardware components integrated on the system board allow remote monitoring and maintenance as well as fast restoration of operation in the event of errors.

Remote monitoring and maintenance avoids time-consuming and costly on-site repairs and reduces service costs. This leads to a reduction in the total cost of ownership and an excellent return on investment for the remote management solution.

The administrator can access all system information and information from the sensors such as fan speeds or voltages via the iRMC S2's Web interface (see section “iRMC S2 with integrated service LAN port” on page 15). He can also start the text-based or graphic console bypass (Advanced Video Redirection, AVR) and get information about remote storage.

I The features of the iRMC S2 Advanced Video Redirection and Remote Storage are available as an option.

Page 19: PRIMERGY RX100 S5 - Fujitsumanuals.ts.fujitsu.com/file/3934/rx100s5-ba-en.pdf · RX100 S5 Operating manual 7 1 Preface The PRIMERGY RX100 S5 server is an Intel-based server for small

RX100 S5 Operating manual 19

Preface Notational conventions

1.4 Notational conventions

The following notational conventions are used in this manual:

Text in italics indicates commands or menu items.

“Quotation marks” indicate names of chapters and terms that are being emphasized.

Ê describes activities that must be performed in the order shown.

V CAUTION! pay particular attention to texts marked with this symbol. Failure to observe this warning may endanger your life, destroy the system or lead to the loss of data.

I indicates additional information, notes and tips.

Page 20: PRIMERGY RX100 S5 - Fujitsumanuals.ts.fujitsu.com/file/3934/rx100s5-ba-en.pdf · RX100 S5 Operating manual 7 1 Preface The PRIMERGY RX100 S5 server is an Intel-based server for small

20 Operating manual RX100 S5

Technical data Preface

1.5 Technical data

Electrical data

Rated voltage range 100 V - 127 V or 200 V - 240 V

Frequency 50 Hz - 60 Hz

Rated current in the basic configuration 100 V - 240 V / 1.8 A - 0.8 A

Max. rated current 100 V - 240 V / 4 A - 2 A

Effective power 177 W

Apparent power 183 VA

Heat dissipation 637 kJ/h (604 btu/h)

Main power fuse 16 A (6.3 A)

Protection class I

Page 21: PRIMERGY RX100 S5 - Fujitsumanuals.ts.fujitsu.com/file/3934/rx100s5-ba-en.pdf · RX100 S5 Operating manual 7 1 Preface The PRIMERGY RX100 S5 server is an Intel-based server for small

RX100 S5 Operating manual 21

Preface Technical data

Compliance with regulations and standards

Product safety and ergonomics

International IEC 60950-1

Europe

Safety EN 60950-1

Ergonomics ISO 9241-3EN 2941-3EK1-ITB 2003:2007

USA / Canada UL 60950-1 / CSA-C22.2 60950-1-03

Taiwan CNS 14336

Electromagnetic compatibility

International CISPRA 24

Europe EN 55022EN 55024EN 61000-3-2EN 61000-3-3ETS 300386

USA / Canada 47CFR part 15 Class A / ICES-003

Taiwan CNS 13438 Class A

Japan VCCI Class A / Jeida

CE marking to EU directives

Low Voltage Directive 2006/95/EC

Electromagnetic compatibility 2004/108/EC

Page 22: PRIMERGY RX100 S5 - Fujitsumanuals.ts.fujitsu.com/file/3934/rx100s5-ba-en.pdf · RX100 S5 Operating manual 7 1 Preface The PRIMERGY RX100 S5 server is an Intel-based server for small

22 Operating manual RX100 S5

Technical data Preface

Mechanical values

Weight

Approx. 11 kg (depending on configuration).

Ventilation clearance

At least 200 mm on the front and rear

Ambient conditions

Condensation during operation must be avoided!

Noise level

Width 430 mm

Depth 560 mm

Height 42.5 mm or 1 HU

Environment class 3K2Environment class 2K2

EN 60721 / IEC 721 Part 3-3EN 60721 / IEC 721 Part 3-2

Temperature:

Operation (3K2) 15 °C ... 35 °C

Transport (2K2) -25 °C ... 60 °C

Humidity 10% ... 85%

Sound power level LWAd (ISO 9296) < 4.9 B (standby)< 6.1 B (operation)

Sound pressure level at adjacent workstationLpAm (ISO 9296)

< 34 dB (A) (standby)< 46 dB (A) (operation)

Page 23: PRIMERGY RX100 S5 - Fujitsumanuals.ts.fujitsu.com/file/3934/rx100s5-ba-en.pdf · RX100 S5 Operating manual 7 1 Preface The PRIMERGY RX100 S5 server is an Intel-based server for small

RX100 S5 Operating manual 23

2 Installation steps, overviewThis chapter contains an overview of the steps necessary to install your server. Links guide you to sections where you can find more detailed information on the individual steps:

Ê First of all, it is essential that you familiarize yourself with the safety infor-mation in chapter “Important information” on page 25.

Ê Unpack the system, check the contents of the package for visible transport damage and check whether the items delivered correspond to the details on the delivery note (see section “Unpacking the server” on page 40).

Ê Transport the server to the place where you want to set it up.

Ê Make sure that all necessary manuals (see “Documentation overview” on page 8) are available; print out the PDF files if required.

Ê Fit the server in the rack (see section “Installing/removing the server in/from the rack” on page 41).

Ê Wire the server. Follow the instructions in sections “Connecting devices to the server” on page 51 and “Instructions for connecting/disconnecting cables” on page 54.

Ê Connect the server to the mains (see section “Connecting the server to the mains” on page 53).

Ê Familiarize yourself with the controls and indicators on the front and rear of the server (see section “Controls and indicators” on page 55).

Page 24: PRIMERGY RX100 S5 - Fujitsumanuals.ts.fujitsu.com/file/3934/rx100s5-ba-en.pdf · RX100 S5 Operating manual 7 1 Preface The PRIMERGY RX100 S5 server is an Intel-based server for small

24 Operating manual RX100 S5

Installation steps, overview

Ê Configure the server and install the desired operating system and applica-tions. The following options are available:

– Remote configuration and installation with ServerStart:

The ServerStart DVD supplied allows you to conveniently configure the server and install the operating system.

Details on how to operate ServerStart, as well as some additional infor-mation, can be found in the “PRIMERGY ServerView Suite - ServerStart” manual.

Configuration information can also be found in section “Configuration with ServerStart” on page 69.

– Local configuration and installation with or without ServerStart (see section “Configuration with ServerStart” on page 69 or section “Configu-ration without ServerStart” on page 70).

Page 25: PRIMERGY RX100 S5 - Fujitsumanuals.ts.fujitsu.com/file/3934/rx100s5-ba-en.pdf · RX100 S5 Operating manual 7 1 Preface The PRIMERGY RX100 S5 server is an Intel-based server for small

RX100 S5 Operating manual 25

3 Important informationIn this chapter you will find essential information regarding safety when working on your server.

3.1 Safety instructions

I The following safety instructions are also provided in the manual “Safety notes and other important information”.

This device meets the relevant safety regulations for IT equipment. If you have any questions about whether you can install the server in the intended environment, please contact your sales outlet or our customer service team.

V CAUTION!

● The actions described in this manual should only be performed by technical specialists.

● Repairs to the device that do not relate to CSS failures must only be carried out by service personnel. Please note that unauthorized inter-ference with the system will void the warranty and exempt the manufacturer from all liability.

● Any failure to observe the guidelines in this manual, and any improper repairs could expose the user to risks (electric shock, energy hazards, fire hazards) or damage the equipment.

Page 26: PRIMERGY RX100 S5 - Fujitsumanuals.ts.fujitsu.com/file/3934/rx100s5-ba-en.pdf · RX100 S5 Operating manual 7 1 Preface The PRIMERGY RX100 S5 server is an Intel-based server for small

26 Operating manual RX100 S5

Safety instructions Important information

Before starting up

V CAUTION!

● During installation and before operating the device, observe the instructions on environmental conditions for your device (see section “Technical data” on page 20).

● If the server has been moved from a cold environment, condensation may form both inside and on the outside of the machine.

Wait until the server has acclimatized to room temperature and is absolutely dry before starting it up. Material damage may be caused to the server if this requirement is not met.

● Only transport the server in the original packaging or in packaging that protects it from impacts and jolts.

Installation and operation

V CAUTION!

● This unit should not be operated in ambient temperatures above 35 °C.

● If the unit is integrated into an installation that draws power from an industrial power supply network with an IEC309 connector, the power supply's fuse protection must comply with the requirements for non-industrial power supply networks for type A connectors.

● The unit automatically adjusts itself to a mains voltage in a range of 100 V - 127 V or 200 V - 240 V. Ensure that the local mains voltage lies within these limits.

● This device must only be connected to properly grounded shock-proof sockets or insulated sockets of the rack's internal power supply with tested and approved power cables.

● Ensure that the device is connected to a grounded shockproof socket close to the device.

Page 27: PRIMERGY RX100 S5 - Fujitsumanuals.ts.fujitsu.com/file/3934/rx100s5-ba-en.pdf · RX100 S5 Operating manual 7 1 Preface The PRIMERGY RX100 S5 server is an Intel-based server for small

RX100 S5 Operating manual 27

Important information Safety instructions

V CAUTION!

● Ensure that the power sockets on the device and the grounded shock-proof sockets are freely accessible.

● The On/Off button or the main power switch (if present) does not isolate the device from the mains power supply. To disconnect it completely from the mains power supply, unplug all network power plugs from the grounded shockproof sockets.

● Always connect the server and the attached peripherals to the same power circuit. Otherwise you run the risk of losing data if, for example, the server is still running but a peripheral device (e.g. memory subsystem) fails during a power outage.

● Data cables must be adequately shielded.

● The EN 50173 and EN 50174-1/2 standards apply for LAN cabling. The minimum requirement is the use of a category 5 screened LAN cable for 10/100 Mbps Ethernet, or a category 5e cable for Gigabit Ethernet. The requirements from the ISO/IEC 11801 specification must also be met.

● Route the cables in such a way that they do not create a potential hazard (make sure no-one can trip over them) and that they cannot be damaged. When connecting the server, refer to the relevant instructions in this manual.

● Never connect or disconnect data transmission lines during a storm (risk of lightning strike).

● Make sure that no objects (e.g. jewelery, paperclips etc.) or liquids can get inside the server (risk of electric shock, short circuit).

● In emergencies (e.g. damaged casing, controls or cables, penetration of liquids or foreign bodies), switch off the server immediately, remove all power plugs and contact your sales outlet or customer service team.

Page 28: PRIMERGY RX100 S5 - Fujitsumanuals.ts.fujitsu.com/file/3934/rx100s5-ba-en.pdf · RX100 S5 Operating manual 7 1 Preface The PRIMERGY RX100 S5 server is an Intel-based server for small

28 Operating manual RX100 S5

Safety instructions Important information

V CAUTION!

● Proper operation of the system (in accordance with IEC 60950-1/EN 60950-1) is only ensured if the casing is completely assembled and the rear covers for the installation slots have been fitted (electric shock, cooling, fire protection, interference suppression).

● Only install system expansions that satisfy the requirements and rules governing safety and electromagnetic compatibility and those relating to telecommunication terminals. If you install other expan-sions, they may damage the system or violate the safety regulations. Information on which system expansions are approved for installation can be obtained from our customer service center or your sales outlet.

● The components marked with a warning notice (e.g. lightning symbol) may only be opened, removed or exchanged by authorized, qualified personnel. Exception: CCS components can be replaced.

● The warranty is void if the server is damaged during installation or replacement of system expansions.

● Only set screen resolutions and refresh rates that are specified in the operating manual for the monitor. Otherwise, you may damage your monitor. If you are in any doubt, contact your sales outlet or customer service center.

Page 29: PRIMERGY RX100 S5 - Fujitsumanuals.ts.fujitsu.com/file/3934/rx100s5-ba-en.pdf · RX100 S5 Operating manual 7 1 Preface The PRIMERGY RX100 S5 server is an Intel-based server for small

RX100 S5 Operating manual 29

Important information Safety instructions

Batteries

V CAUTION!

● Incorrect replacement of batteries may lead to a risk of explosion. The batteries may only be replaced with identical batteries or with a type recommended by the manufacturer (see the technical manual for the system board).

● Do not throw batteries into the trash can. They must be disposed of in accordance with local regulations concerning special waste.

● The battery must be disposed of in accordance with local regulations concerning special waste.

● Replace the lithium battery on the system board in accordance with the instructions in the technical manual for the system board.

● All batteries containing pollutants are marked with a symbol (a crossed-out garbage can). In addition, the marking is provided with the chemical symbol of the heavy metal decisive for the classification as a pollutant:

Cd Cadmium Hg Mercury Pb Lead

Page 30: PRIMERGY RX100 S5 - Fujitsumanuals.ts.fujitsu.com/file/3934/rx100s5-ba-en.pdf · RX100 S5 Operating manual 7 1 Preface The PRIMERGY RX100 S5 server is an Intel-based server for small

30 Operating manual RX100 S5

Safety instructions Important information

Working with CDs/DVDs and CD/DVD drives

When working with devices with CD/DVD drives, these instructions must be followed.

V CAUTION!

● Only use CDs/DVDs that are in perfect condition in your server's CD/DVD drive, in order to prevent data loss, equipment damage and injury.

● Check each CD/DVD for damage, cracks, breakages etc. before inserting it in the drive.

Note that any additional labels applied may change the mechanical properties of a CD/DVD and cause imbalance.

Damaged and imbalanced CDs/DVDs can break at high drive speeds (data loss).

Under certain circumstances, sharp CD/DVD fragments can pierce the cover of the CD/DVD drive (equipment damage) and can fly out of the device (danger of injury, particularly to uncovered body parts such as the face or neck).

I You can prevent mechanical damage and damage to the CD/DVD drive, as well as premature CD/DVD wear, by observing the following sugges-tions:

– Only insert CDs/DVDs in the drive when needed and remove them after use.

– Store the CDs/DVDs in suitable sleeves.– Protect the CDs/DVDs from exposure to heat and direct sunlight.

Laser information

The CD/DVD drive complies with IEC 60825-1 laser class 1.

V CAUTION!

The CD/DVD drive contains a light-emitting diode (LED), which under certain circumstances produces a laser beam stronger than laser class 1. Looking directly at this beam is dangerous.

Never remove parts of the CD/DVD drive casing!

Page 31: PRIMERGY RX100 S5 - Fujitsumanuals.ts.fujitsu.com/file/3934/rx100s5-ba-en.pdf · RX100 S5 Operating manual 7 1 Preface The PRIMERGY RX100 S5 server is an Intel-based server for small

RX100 S5 Operating manual 31

Important information Safety instructions

Modules with Electrostatic-Sensitive Devices

Modules with electrostatic-sensitive devices are identified by the following sticker:

Figure 1: ESD label

When you handle components fitted with ESDs, you must always observe the following points:

● Switch off the system and remove the power plugs from the power outlets before installing or removing components with ESDs.

● You must always discharge static build-up (e.g. by touching a grounded object) before working with such components.

● Any devices or tools that are used must be free of electrostatic charge.

● Wear a suitable grounding cable that connects you to the external chassis of the system unit.

● Always hold components with ESDs at the edges or at the points marked green (touch points).

● Do not touch any connectors or conduction paths on an ESD.

● Place all the components on a pad which is free of electrostatic charge.

I For a detailed description of how to handle ESD components, see the relevant European or international standards (EN 61340-5-1, ANSI/ESD S20.20).

Page 32: PRIMERGY RX100 S5 - Fujitsumanuals.ts.fujitsu.com/file/3934/rx100s5-ba-en.pdf · RX100 S5 Operating manual 7 1 Preface The PRIMERGY RX100 S5 server is an Intel-based server for small

32 Operating manual RX100 S5

CE conformity Important information

Other important information:

● During cleaning, observe the instructions in section “Cleaning the server” on page 70.

● Keep this operating manual and the other documentation (such as the technical manual, CD) close to the device. All documentation must be included if the equipment is passed on to a third party.

3.2 CE conformity

The system complies with the requirements of the EC directives 2004/108/EC regarding “Electromagnetic Compatibility” and 2006/95/EC “Low Voltage Directive”. This is indicated by the CE marking (CE = Communauté Européenne).

Page 33: PRIMERGY RX100 S5 - Fujitsumanuals.ts.fujitsu.com/file/3934/rx100s5-ba-en.pdf · RX100 S5 Operating manual 7 1 Preface The PRIMERGY RX100 S5 server is an Intel-based server for small

RX100 S5 Operating manual 33

Important information FCC Class A Compliance Statement

3.3 FCC Class A Compliance Statement

If there is an FCC statement on the device, then:

The following statement applies to the products covered in this manual, unless otherwise specified herein. The statement for other products will appear in the accompanying documentation.

NOTE:

This equipment has been tested and found to comply with the limits for a “Class A” digital device, pursuant to Part 15 of the FCC rules and meets all requirements of the Canadian Interference-Causing Equipment Standard ICES-003 for digital apparatus. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in strict accordance with the instructions, may cause harmful interference to radio communications. However, there is no warranty that inter-ference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:

● Reorient or relocate the receiving antenna.

● Increase the separation between equipment and the receiver.

● Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.

● Consult the dealer or an experienced radio/TV technician for help.

Fujitsu Technology Solutions is not responsible for any radio or television inter-ference caused by unauthorized modifications of this equipment or the substi-tution or attachment of connecting cables and equipment other than those specified by Fujitsu Technology Solutions. The correction of interferences caused by such unauthorized modification, substitution or attachment will be the responsibility of the user.

The use of shielded I/O cables is required when connecting this equipment to any and all optional peripheral or host devices. Failure to do so may violate FCC and ICES rules.

Page 34: PRIMERGY RX100 S5 - Fujitsumanuals.ts.fujitsu.com/file/3934/rx100s5-ba-en.pdf · RX100 S5 Operating manual 7 1 Preface The PRIMERGY RX100 S5 server is an Intel-based server for small

34 Operating manual RX100 S5

Transporting the server Important information

WARNING:

This is a class A product. In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures.

3.4 Transporting the server

V CAUTION!

Only transport the server in its original packaging or in packaging that protects it from impacts and jolts. Do not unpack the server until it is at its installation location.

If you need to lift or transport the server, ask other people to help you.

Never lift or carry the device by the handles on the front panel.

Page 35: PRIMERGY RX100 S5 - Fujitsumanuals.ts.fujitsu.com/file/3934/rx100s5-ba-en.pdf · RX100 S5 Operating manual 7 1 Preface The PRIMERGY RX100 S5 server is an Intel-based server for small

RX100 S5 Operating manual 35

Important information Rack installation instructions

3.5 Rack installation instructions

● When connecting and disconnecting cables, follow the instructions in chapter “Important information” in the technical manual for the corre-sponding rack. The technical manual for the rack is supplied along with the rack itself.

● When setting up the rack, make sure that the anti-tilt mechanism is correctly fitted.

● For safety reasons, no more than one unit may be removed from the rack at any one time during installation and maintenance work.

● If several units are simultaneously removed from the rack, there is a risk that the rack could tip over.

● The rack must be connected to the power supply by an authorized specialist (electrician).

● If the server is integrated into an installation that draws power from an indus-trial power supply network with an IEC309 connector, the power supply's fuse protection must comply with the requirements for non-industrial power supply networks for type A connectors.

Page 36: PRIMERGY RX100 S5 - Fujitsumanuals.ts.fujitsu.com/file/3934/rx100s5-ba-en.pdf · RX100 S5 Operating manual 7 1 Preface The PRIMERGY RX100 S5 server is an Intel-based server for small

36 Operating manual RX100 S5

Environmental protection Important information

3.6 Environmental protection

Environmentally-friendly product design and development

This product has been designed in accordance with the Fujitsu Technology Solutions standard for “environmentally friendly product design and devel-opment”. This means that key factors such as durability, selection and labeling of materials, emissions, packaging, ease of dismantling and recycling have been taken into account.

This saves resources and thus reduces the harm done to the environment.

Energy-saving information

Devices that do not need to be constantly switched on should be switched off until they are needed as well as during long breaks and after completion of work.

Packaging information

Do not throw away the packaging. You may need it later for transporting the system. If possible, the equipment should only be transported in its original packaging.

Information on handling consumables

Please dispose of printer consumables and batteries in accordance with the applicable national regulations.

In accordance with EU directives, batteries must not be disposed of with unsorted domestic waste. They can be returned free of charge to the manufac-turer, dealer or an authorized agent for recycling or disposal.

All batteries containing pollutants are marked with a symbol (a crossed-out garbage can). They are also marked with the chemical symbol for the heavy metal that causes them to be categorized as containing pollutants:

Cd CadmiumHg MercuryPb Lead

Page 37: PRIMERGY RX100 S5 - Fujitsumanuals.ts.fujitsu.com/file/3934/rx100s5-ba-en.pdf · RX100 S5 Operating manual 7 1 Preface The PRIMERGY RX100 S5 server is an Intel-based server for small

RX100 S5 Operating manual 37

Important information Environmental protection

Labels on plastic casing parts

Please avoid sticking your own labels on plastic parts wherever possible, since this makes it difficult to recycle them.

Returns, recycling and disposal

Details regarding the return and recycling of devices and consumables within Europe can also be found in the “Returning used devices” manual, via your local Fujitsu Technology Solutions branch or from our recycling center in Paderborn:

Fujitsu Technology SolutionsRecycling CenterD-33106 Paderborn

Tel. +49 5251 8 18010

Fax +49 5251 8 18015

The device must not be disposed of with domestic waste. This device is labeled in compliance with European directive 2002/96/EC on waste electrical and electronic equipment (WEEE).

This directive sets the framework for returning and recycling used equipment and is valid across the EU. When returning your used device, please use the return and collection systems available to you. Further information can be found athttp://ts.fujitsu.com/recycling.

Page 38: PRIMERGY RX100 S5 - Fujitsumanuals.ts.fujitsu.com/file/3934/rx100s5-ba-en.pdf · RX100 S5 Operating manual 7 1 Preface The PRIMERGY RX100 S5 server is an Intel-based server for small
Page 39: PRIMERGY RX100 S5 - Fujitsumanuals.ts.fujitsu.com/file/3934/rx100s5-ba-en.pdf · RX100 S5 Operating manual 7 1 Preface The PRIMERGY RX100 S5 server is an Intel-based server for small

RX100 S5 Operating manual 39

4 Hardware installationV CAUTION!

● Follow the safety instructions in the chapter “Important information” on page 25.

● Do not expose the server to extreme environmental conditions (see “Ambient conditions” on page 22). Protect the server from dust, humidity and heat.

● Make sure that the server is acclimatized for the time indicated in this table before putting it into operation.

In table “Acclimatization time”, the temperature difference refers to the difference between the operating environment temperature and the temperature to which the server was exposed previously (outside, transport or storage temperature).

Temperature difference (°C) Minimum acclimatization time (hours)

5 3

10 5

15 7

20 8

25 9

30 10

Table 1: Acclimatization time

Page 40: PRIMERGY RX100 S5 - Fujitsumanuals.ts.fujitsu.com/file/3934/rx100s5-ba-en.pdf · RX100 S5 Operating manual 7 1 Preface The PRIMERGY RX100 S5 server is an Intel-based server for small

40 Operating manual RX100 S5

Unpacking the server Hardware installation

4.1 Unpacking the server

V CAUTION!

Follow the safety instructions in the “Important information” on page 25 chapter.

The server must always be lifted or carried by at least two people.

Do not unpack the server until it is at its installation location.

Ê Transport the server to the place where you want to set it up.

Ê Unpack all individual parts.

Keep the original packaging in case you want to transport the server again.

Ê Check the delivery for any damage during transport.

Ê Check whether the items delivered match the details on the delivery note.

The product name and serial number of the product can be found on the identi-fication rating plate.

Ê Notify your supplier immediately should you discover that the items delivered do not correspond to the delivery note.

Page 41: PRIMERGY RX100 S5 - Fujitsumanuals.ts.fujitsu.com/file/3934/rx100s5-ba-en.pdf · RX100 S5 Operating manual 7 1 Preface The PRIMERGY RX100 S5 server is an Intel-based server for small

RX100 S5 Operating manual 41

Hardware installation Installing/removing the server in/from the rack

4.2 Installing/removing the server in/from the rack

V CAUTION!

● Follow the safety instructions in chapter “Important information” on page 25 and section “Rack installation instructions” on page 35.

● The rack can tip over when more than one unit is removed.

V CAUTION!

The server does not have cable management in the rack.

Before removal, all cables connected to the server must be removed from the sockets. Proceed as follows:

● Exit all applications and shut down the operating system properly.

● Switch off the server.

● Disconnect and remove all cables connected to the server.

● Remove the server.

Page 42: PRIMERGY RX100 S5 - Fujitsumanuals.ts.fujitsu.com/file/3934/rx100s5-ba-en.pdf · RX100 S5 Operating manual 7 1 Preface The PRIMERGY RX100 S5 server is an Intel-based server for small

42 Operating manual RX100 S5

Installing/removing the server in/from the rack Hardware installation

4.2.1 Rack requirements

The rack systems from Fujitsu Technology Solutions (PRIMECENTER Rack and DataCenter Rack) fully support installation of the PRIMERGY RX100 S5 server. Installation in most current rack systems from other manufacturers (3rd party racks) is also supported.

To accommodate the ventilation concept and ensure proper ventilation, any unused areas in the rack must be sealed using dummy covers.

The power is supplied via the multiple socket outlets fitted in the rack.

The main features of the rack systems from Fujitsu Technology Solutions are as follows:

PRIMECENTER rack

– Front bolted telescopic rails (a support bracket is used in the lower left area).

The rails have a linear alignment feature to ensure that they can be adjusted to different rack depths.

DataCenter Rack

– Front bolted telescopic rails (a support bracket is used in the lower left area).

The rails have a linear alignment feature to ensure that they can be adjusted to different rack depths.

Page 43: PRIMERGY RX100 S5 - Fujitsumanuals.ts.fujitsu.com/file/3934/rx100s5-ba-en.pdf · RX100 S5 Operating manual 7 1 Preface The PRIMERGY RX100 S5 server is an Intel-based server for small

RX100 S5 Operating manual 43

Hardware installation Installing/removing the server in/from the rack

3rd party rack

Certain general conditions must be met:

– Installation dimensions (see the dimensions shown in figure 2 on page 44):

– You must ensure that the safety mechanisms on the server, e.g. stoppers or retaining systems, are functioning correctly.

– The shape of the rack support uprights must ensure that the rails can be bolted to the front.

– Telescopic rails screwed to the front.

The rails have a linear alignment feature to ensure that they can be adjusted to different rack depths.

– Climatic conditions:

To ventilate the server, an unimpeded air inlet on the front of the rack and an air outlet on the rear of the rack are required.

In principle the ventilation concept envisages that the necessary cooling is achieved by the horizontal self-ventilation of the installed devices (air flow from front to back).

1 Front of rack

2 Rear of rack

A Rack depth (comparison PRIMECENTER rack 940/1000/1100 mm)

B Rack width (comparison PRIMECENTER rack 700 mm)

C Clearance for 19” installation level

C1 Front 19” installation level

C2 Rear 19” installation level

D Cable routing area (cable area depth) and ventilation

E Space for front panel and ventilation

F Space for right and left support systems

P PRIMERGY rack installation depth

a1 Front left support upright

a2 Front right support upright

b1 Rear left support upright

b2 Rear right support upright

Page 44: PRIMERGY RX100 S5 - Fujitsumanuals.ts.fujitsu.com/file/3934/rx100s5-ba-en.pdf · RX100 S5 Operating manual 7 1 Preface The PRIMERGY RX100 S5 server is an Intel-based server for small

44 Operating manual RX100 S5

Installing/removing the server in/from the rack Hardware installation

– Power supply:

For installation in 3rd party racks, you must ensure that the appropriate socket strips are present.

Figure 2: Mechanical requirements

Page 45: PRIMERGY RX100 S5 - Fujitsumanuals.ts.fujitsu.com/file/3934/rx100s5-ba-en.pdf · RX100 S5 Operating manual 7 1 Preface The PRIMERGY RX100 S5 server is an Intel-based server for small

RX100 S5 Operating manual 45

Hardware installation Installing/removing the server in/from the rack

4.2.2 Installation in PRIMECENTER/DataCenter rack

For installation in a PRIMECENTER/DataCenter rack, the following parts are required:

– Support bracket– One left and one right telescopic rail (assembled) – M5x10 screws with integrated plugwashers

I General information is provided in the Technical Manual for the PRIME-CENTER and/or DataCenter Rack.

Fitting the support bracket

When mounting the left telescopic rail in the PRIMECENTER/DataCenter Rack, the supplied support bracket must first be mounted on the rear left support upright flush with the bottom edge of the device.

Figure 3: Fitting the support bracket

Ê Position the support bracket at the corresponding height on the rear left support upright, (insert lug in corresponding hole) (1).

Ê Secure the bracket with two screws incl. plug washers (2).

1

2

Page 46: PRIMERGY RX100 S5 - Fujitsumanuals.ts.fujitsu.com/file/3934/rx100s5-ba-en.pdf · RX100 S5 Operating manual 7 1 Preface The PRIMERGY RX100 S5 server is an Intel-based server for small

46 Operating manual RX100 S5

Installing/removing the server in/from the rack Hardware installation

Removing the outer telescopic rail

Figure 4: Removing the outer telescopic rail

Ê Extend the telescopic rail fully (1).

Ê Press the release spring (2) and remove the server rail.

Ê Repeat both steps with the second telescopic rail.

I No nuts are required to secure the telescopic rails as the fixing holes on the rails are threaded.

2

1

1

Page 47: PRIMERGY RX100 S5 - Fujitsumanuals.ts.fujitsu.com/file/3934/rx100s5-ba-en.pdf · RX100 S5 Operating manual 7 1 Preface The PRIMERGY RX100 S5 server is an Intel-based server for small

RX100 S5 Operating manual 47

Hardware installation Installing/removing the server in/from the rack

Installing the telescopic rail with variable support

Figure 5: Fit the left telescopic rail in the PRIMECENTER/DataCenter Rack

Ê Position the left rail (1) on the support bracket with the retaining bolts in the upper and lower square catch (a).

Ê Press the left rail together until its front end passes behind the front left support upright, then release (2).

Ê Fasten the rail with a screw (M5) to the left front support upright (3).

Ê Repeat the steps with the right telescopic rail (to be secured to the right support uprights).

Ê Fit the PRIMECENTER/DataCenter rack cable management as described in the technical manual for the corresponding rack.

Ê Insert the server (see section “Inserting the server” on page 49).

Ê Route the cables as described in the technical manual for the rack in question with the server pushed in.

3

1

a

2

Page 48: PRIMERGY RX100 S5 - Fujitsumanuals.ts.fujitsu.com/file/3934/rx100s5-ba-en.pdf · RX100 S5 Operating manual 7 1 Preface The PRIMERGY RX100 S5 server is an Intel-based server for small

48 Operating manual RX100 S5

Installing/removing the server in/from the rack Hardware installation

4.2.3 Installation in 3rd party racks

The following parts are required to install the server in 3rd party racks:

– One left and one right telescopic rail (assembled) – M5x10 screws with integrated plugwashers

Ê Refer to the manual from the rack manufacturer for details of the mechanical installation and the climatic conditions.

V CAUTION!

When installing in 3rd party racks, it must be ensured that an air flow from the front to the back of the rack is guaranteed.

Ê Fit the required original parts (e.g. support bracket).

I Under certain circumstances, you will not be able to use some of the parts from the rack installation kit supplied - you will need to use original 3rd party rack parts instead.

Ê Remove the outer telescopic rail as described in page 46 (figure 4).

Page 49: PRIMERGY RX100 S5 - Fujitsumanuals.ts.fujitsu.com/file/3934/rx100s5-ba-en.pdf · RX100 S5 Operating manual 7 1 Preface The PRIMERGY RX100 S5 server is an Intel-based server for small

RX100 S5 Operating manual 49

Hardware installation Installing/removing the server in/from the rack

4.2.4 Inserting the server

Figure 6: Preparing the server

Ê Place the server rails on the three screws on both sides of the server and slide the server rails forwards to secure them (1).

The safety spring (a) must engage with an audible click.

1

a

Page 50: PRIMERGY RX100 S5 - Fujitsumanuals.ts.fujitsu.com/file/3934/rx100s5-ba-en.pdf · RX100 S5 Operating manual 7 1 Preface The PRIMERGY RX100 S5 server is an Intel-based server for small

50 Operating manual RX100 S5

Installing/removing the server in/from the rack Hardware installation

Figure 7: Inserting the server

Ê Push the prepared server into the rails that are attached to the rack until the server rails engage (1).

I Ensure that the server is inserted horizontally and is not tilted.

Ê Press the safety springs in on both sides (2).

Ê Gently push the server as far as it will go into the rack (3).

Ê Fasten the server to the rack (4) using the two knurled screws (front panel).

To remove the server, follow this procedure in reverse.

1

2

1

4

43

Page 51: PRIMERGY RX100 S5 - Fujitsumanuals.ts.fujitsu.com/file/3934/rx100s5-ba-en.pdf · RX100 S5 Operating manual 7 1 Preface The PRIMERGY RX100 S5 server is an Intel-based server for small

RX100 S5 Operating manual 51

Hardware installation Connecting devices to the server

4.3 Connecting devices to the server

The ports for external devices are on the front and rear of the server. The additional ports available on your server depend on the expansion cards installed.

I Some of the devices that can be connected may require special software, e.g. drivers (see the documentation for the connected device).

Figure 8: Ports on the front

Two USB ports are located on the front of the server (1).

1

Page 52: PRIMERGY RX100 S5 - Fujitsumanuals.ts.fujitsu.com/file/3934/rx100s5-ba-en.pdf · RX100 S5 Operating manual 7 1 Preface The PRIMERGY RX100 S5 server is an Intel-based server for small

52 Operating manual RX100 S5

Connecting devices to the server Hardware installation

The standard ports on the rear are marked with symbols, and some are color-coded:

Figure 9: Ports on the rear

Ê Connect the data cables to the server and peripherals.

4.3.1 Connecting the monitor

Ê Plug the data cable for the monitor into the monitor port on the server (item 5 in figure 9 on page 52).

Ê Connect the insulated connector on the monitor power cable to a grounded outlet in the rack's socket strip (see also the technical manual for the rack).

1 service LAN port 6 LAN port 2

2 Serial port COM1* 7 LAN port 1

3 PS/2 mouse port (green) 8 USB port 2

4 PS/2 keyboard port (purple) 9 USB port 1

5 Monitor port (blue)

* The serial interface COM1 can be used as the standard interface or for communication with iRMC.

1 2 3

456789

Page 53: PRIMERGY RX100 S5 - Fujitsumanuals.ts.fujitsu.com/file/3934/rx100s5-ba-en.pdf · RX100 S5 Operating manual 7 1 Preface The PRIMERGY RX100 S5 server is an Intel-based server for small

RX100 S5 Operating manual 53

Hardware installation Connecting the server to the mains

4.4 Connecting the server to the mains

The server has a fixed power supply unit.

V CAUTION!

The server is automatically set to a mains voltage in the range 100 V - 127 V or 200 V - 240 V. You may only operate the server if its rated voltage range corresponds to the local mains voltage.

Figure 10: Connecting the server to the mains

Ê Connect the power cord to the server power supply unit (1).

I As an option, you can secure the power cord in the cable clamp so that the insulated connector cannot be disconnected from the server accidentally. The cable clamp has to be clipped to the server's power supply unit.

Ê Connect the mains connector to an outlet on the rack's socket strip (2).

I For details, please see the technical manual for the rack.

1

2

Page 54: PRIMERGY RX100 S5 - Fujitsumanuals.ts.fujitsu.com/file/3934/rx100s5-ba-en.pdf · RX100 S5 Operating manual 7 1 Preface The PRIMERGY RX100 S5 server is an Intel-based server for small

54 Operating manual RX100 S5

Instructions for connecting/disconnecting cables Hardware installation

4.5 Instructions for connecting/disconnecting cables

V CAUTION!

Make sure you read the documentation for the external devices before connecting them.

Do not connect or disconnect data cables during a thunderstorm.

When removing a cable, always hold it by the plug not by the actual cable.

Connect and disconnect the cables in the order described below.

Connecting cables

Ê Turn off all power and equipment switches.

Ê Disconnect all power plugs from the grounded shockproof sockets.

Ê Plug all cables into the server and peripherals. Secure the data transmission cable connections (e. g. nut retention).

Ê Plug all data communication cables into the utility sockets.

Ê Plug all power cables into the grounded shockproof sockets.

Disconnecting cables

Ê Turn off all power and equipment switches.

Ê Disconnect all power plugs from the grounded shockproof sockets.

Ê Unplug all data communication cables from the utility sockets.

Ê Loosen the nut retentions on the connector housings and disconnect the corresponding cables from the server and from the peripherals.

Page 55: PRIMERGY RX100 S5 - Fujitsumanuals.ts.fujitsu.com/file/3934/rx100s5-ba-en.pdf · RX100 S5 Operating manual 7 1 Preface The PRIMERGY RX100 S5 server is an Intel-based server for small

RX100 S5 Operating manual 55

5 Starting up and operationV CAUTION!

Follow the safety instructions in chapter “Important information” on page 25.

5.1 Controls and indicators

5.1.1 Front of server

Figure 11: Controls and indicators on the front panel

1 ServerView Local Service Display 6 NMI button

2 ID button 7 Power-on indicator

3 ID indicator 8 Hard disk activity indicator

4 Reset button 9 CSS/Global Error indicator

5 On/Off button 10 DVD drive activity indicator

ID

!

RST

CSS NMI

1 2 3 4 5

678910

Page 56: PRIMERGY RX100 S5 - Fujitsumanuals.ts.fujitsu.com/file/3934/rx100s5-ba-en.pdf · RX100 S5 Operating manual 7 1 Preface The PRIMERGY RX100 S5 server is an Intel-based server for small

56 Operating manual RX100 S5

Controls and indicators Starting up and operation

5.1.1.1 Controls

ID ID button

Lights up (blue) on the front and on the rear of the server when the ID button is pressed. The two ID indicators are synchronized.

On/Off button

When the system is switched off, it can be switched on again by pressing the On/Off button. When the system is operating, pressing the On/Off button will switch off the system.

I The On/Off button does not disconnect the server from the mains voltage. To disconnect from the mains completely, remove the power plug(s).

RST Reset button

Pressing the reset button reboots the system.

V CAUTION!

Risk of loss of data!

NMI NMI button

V CAUTION!

Do not press! Risk of loss of data!

The NMI button may only be used by service.

Page 57: PRIMERGY RX100 S5 - Fujitsumanuals.ts.fujitsu.com/file/3934/rx100s5-ba-en.pdf · RX100 S5 Operating manual 7 1 Preface The PRIMERGY RX100 S5 server is an Intel-based server for small

RX100 S5 Operating manual 57

Starting up and operation Controls and indicators

5.1.1.2 Indicators on the control panel

ID ID indicator (blue)

Lights up blue when the system has been selected by pressing the ID button. To deactivate, press the button again.

The ID indicator can also be activated via ServerView S2 and its status reported to ServerView S2.

Power-on indicator (green/orange/yellow)

Lights up green when the server is switched ON.

Flashes green when the system is in standby mode.

Lights up orange when the server is in shutdown mode (operating system shutdown) or is switched off.

Lights up yellow during power-on delay.

Hard disk activity indicator (green)

Lights up green when an internal hard disk drive is accessed.

Page 58: PRIMERGY RX100 S5 - Fujitsumanuals.ts.fujitsu.com/file/3934/rx100s5-ba-en.pdf · RX100 S5 Operating manual 7 1 Preface The PRIMERGY RX100 S5 server is an Intel-based server for small

58 Operating manual RX100 S5

Controls and indicators Starting up and operation

CSS CSS/Global Error indicator (yellow/red)

Generally, the three possible states of this indicator have the following meanings:

– Does not light up when the system is OK.– If the event is still acute after a power failure, the indicator is

activated after the restart.– Lights up when a prefailure event was detected. The indicator

also lights up in standby mode.– Flashes when an error was detected. The indicator also

flashes in standby mode.

For more details on the indicated errors, you can consult the System Event Log (SEL), the ServerView Local Service Panel, ServerView S2 or the ServerView Remote Management via iRMC's own Web server.

Depending on the color, the states „light up“ and „flash“ have the following meanings:

– CSS (yellow)

Lights up yellow if a prefailure event was detected for a CSS component.

Flashes yellow if an error was detected that you can fix yourself with the CSS concept (see “Customer Self Service (CSS)” on page 10).

– Global Error (red)

Lights up red if a prefailure event was detected for a non-CSS component.

Flashes red if an error was detected for a service incident.

– CSS/Global Error (yellow/red)

Lights up and/or flashes alternately yellow and/or red if several prefailure events and/or errors were detected at the same time (see above).

!

Page 59: PRIMERGY RX100 S5 - Fujitsumanuals.ts.fujitsu.com/file/3934/rx100s5-ba-en.pdf · RX100 S5 Operating manual 7 1 Preface The PRIMERGY RX100 S5 server is an Intel-based server for small

RX100 S5 Operating manual 59

Starting up and operation Controls and indicators

5.1.1.3 Indicators on the accessible drives/components

DVD drive activity indicator

Lights up green when the storage medium is being accessed.

ServerView Local Service Panel (option)

You can use the slot mechanism to pull out the ServerView Local Service Panel from the server housing and read the information. Press the front of the module to release the lock.

You can also pivot the ServerView Local Service Panel down by an angle of 120° from its normal position. This makes reading easier when the server is located very high in the rack.

Further information on using the ServerView Local Service Panel is provided in the “Customer Self Service (CSS)” manual.

Page 60: PRIMERGY RX100 S5 - Fujitsumanuals.ts.fujitsu.com/file/3934/rx100s5-ba-en.pdf · RX100 S5 Operating manual 7 1 Preface The PRIMERGY RX100 S5 server is an Intel-based server for small

60 Operating manual RX100 S5

Controls and indicators Starting up and operation

Indicators on the hot-plug HDD module

Figure 12: Indicators on the hot-plug HDD module

1 HDD BUSY (green)

– Lit: HDD in active phase (drive active, drive being accessed)– Does not light: HDD inactive

2 HDD FAULT (orange)

– Does not light: no HDD error– Lights up: HDD Faulty or Rebuild Stopped (drive defective/needs

replacing, a rebuild process was stopped or the HDD module is not correctly inserted)

– Slow flashing: HDD Rebuild (the data is being restored after changing a drive)

1 2

Page 61: PRIMERGY RX100 S5 - Fujitsumanuals.ts.fujitsu.com/file/3934/rx100s5-ba-en.pdf · RX100 S5 Operating manual 7 1 Preface The PRIMERGY RX100 S5 server is an Intel-based server for small

RX100 S5 Operating manual 61

Starting up and operation Controls and indicators

5.1.2 Rear of server

Indicators on connection panel (Global Error indicator and CSS indicator)

Figure 13: Global Error indicator and CSS indicator

1 CSS/Global Error indicator (yellow/red)

Generally, the three possible states of this indicator have the following meanings:

– Does not light up when the system is OK.– If the event is still acute after a power failure, the indicator is activated

after the restart.– Lights up when a prefailure event was detected. The indicator also

lights up in standby mode.– Flashes when an error was detected. The indicator also flashes in

standby mode.

For more details on the indicated errors, you can consult the System Event Log (SEL), the ServerView Local Service Panel, ServerView S2 or the ServerView Remote Management via iRMC's own Web server.

1

!

CSS

Page 62: PRIMERGY RX100 S5 - Fujitsumanuals.ts.fujitsu.com/file/3934/rx100s5-ba-en.pdf · RX100 S5 Operating manual 7 1 Preface The PRIMERGY RX100 S5 server is an Intel-based server for small

62 Operating manual RX100 S5

Controls and indicators Starting up and operation

Depending on the color, the states „light up“ and „flash“ have the following meanings:

– CSS (yellow)

Lights up yellow if a prefailure event was detected for a CSS component.

Flashes yellow if an error was detected that you can fix yourself with the CSS concept (see “Customer Self Service (CSS)” on page 10).

– Global Error (red)

Lights up red if a prefailure event was detected for a non-CSS component.

Flashes red if an error was detected for a service incident.

– CSS/Global Error (yellow/red)

Lights up and/or flashes alternately yellow and/or red if several prefailure events and/or errors were detected at the same time (see above).

Page 63: PRIMERGY RX100 S5 - Fujitsumanuals.ts.fujitsu.com/file/3934/rx100s5-ba-en.pdf · RX100 S5 Operating manual 7 1 Preface The PRIMERGY RX100 S5 server is an Intel-based server for small

RX100 S5 Operating manual 63

Starting up and operation Controls and indicators

Indicators on the connection panel (ID indicator)

Figure 14: ID indicator

1 ID indicator (blue)

ID indicators on the front and rear of the server light up when the ID button is pressed. The two ID indicators are synchronized.

Lights up blue when the system has been selected by pressing the ID button. To deactivate, press the button again.

The ID indicator can also be activated via ServerView S2 and its status reported to ServerView S2.

1

ID

Page 64: PRIMERGY RX100 S5 - Fujitsumanuals.ts.fujitsu.com/file/3934/rx100s5-ba-en.pdf · RX100 S5 Operating manual 7 1 Preface The PRIMERGY RX100 S5 server is an Intel-based server for small

64 Operating manual RX100 S5

Controls and indicators Starting up and operation

Indicators on the connection panel (LAN indicators)

Figure 15: LAN indicators

1 LAN activity indicator (service LAN)

Lights up green if a LAN connection exists.

Does not light up if no LAN connection exists.

Flashes green when a LAN transfer is in progress.

2 LAN transfer rate indicator (service LAN)

Lights up green for a LAN transfer rate of 100 Mbps.

Does not light up for a LAN transfer rate of 10 Mbps.

3 LAN activity indicator (standard LAN)

Lights up green if a LAN connection exists.

Does not light up if no LAN connection exists.

Flashes green when a LAN transfer is in progress.

4 LAN transfer rate indicator (standard LAN)

Lights up orange for a LAN transfer rate of 1 Gbps.

Lights up green for a LAN transfer rate of 100 Mbps.

Does not light up for a LAN transfer rate of 10 Mbps.

1 2

43 43

Page 65: PRIMERGY RX100 S5 - Fujitsumanuals.ts.fujitsu.com/file/3934/rx100s5-ba-en.pdf · RX100 S5 Operating manual 7 1 Preface The PRIMERGY RX100 S5 server is an Intel-based server for small

RX100 S5 Operating manual 65

Starting up and operation Switching the server on and off

5.2 Switching the server on and off

The indicators and controls for switching on and off can be found in section “Controls and indicators” on page 55.

V CAUTION!

It nothing appears on the screen but flickering stripes after switching on the server, switch the server off immediately (see chapter “Trouble-shooting and tips” on page 73).

The On/Off button does not disconnect the server from the mains voltage. Pull out the power plug to completely disconnect the server from the line voltage.

Switching the server on

The power-on indicator lights up orange.

– Starting up for the first time:

Ê Press the On/Off button.

Ê Insert the ServerStart DVD in the DVD drive.

Ê Follow the on-screen instructions (see also section “Configuring the server” on page 67).

– System already installed:

Ê Press the On/Off button.

The server is switched on, performs a system test and boots the operating system.

Switching the server off

Power-on indicator lights up green.

Ê Shut down the operating system properly.

The server is switched off automatically and goes into standby mode. The power-on indicator lights up orange.

I If the operating system does not switch the server off automatically, press the On/Off button for at least four seconds.

Page 66: PRIMERGY RX100 S5 - Fujitsumanuals.ts.fujitsu.com/file/3934/rx100s5-ba-en.pdf · RX100 S5 Operating manual 7 1 Preface The PRIMERGY RX100 S5 server is an Intel-based server for small

66 Operating manual RX100 S5

Switching the server on and off Starting up and operation

Other On/Off options

In addition to the On/Off button, the server can be switched on and off in the following ways:

– Specified switch on time / switch off time

The server is switched on or off at a time specified in the ServerView S2 program.

– Ring indicator

The server is switched on by an internal or external modem.

– Wake up On LAN (WOL)

The server is switched on by a command via the LAN (Magic PacketTM).

– After power failure

The server is automatically switched on following a power failure (depending on the BIOS settings).

– Power button override

The server can be switched off immediately by pressing and holding the On/Off button (approx. 4-5 sec.).

V CAUTION!

There is a risk that data may be lost.

– iRMC S2

iRMC S2 offers various options for switching the server on and off, e.g. via the Power On Oss page of the iRMC S2 Web interface.

Page 67: PRIMERGY RX100 S5 - Fujitsumanuals.ts.fujitsu.com/file/3934/rx100s5-ba-en.pdf · RX100 S5 Operating manual 7 1 Preface The PRIMERGY RX100 S5 server is an Intel-based server for small

RX100 S5 Operating manual 67

Starting up and operation Configuring the server

5.3 Configuring the server

This section contains information about configuring the server and installing the operating system.

I Make sure that the energy saving functions are disabled in the BIOS Setup during server operation.

5.3.1 Hard disk drive write cache

By default, the hard disk write cache is deactivated. During write operations the data is written immediately to the hard disks.

You can change this default setting. You can activate the hard disk write cache to increase the data flow for write operations to the hard disk.

V CAUTION!

If the hard disk write cache is active, data can be lost if there is a power failure.

Further information about configuration can be found in the “Embedded MegaRAID Software User’s Guide”.

Using the ServerView RAID

ServerView RAID can be used to make the settings for the hard disk write cache. Further information is provided in the “ServerView RAID User's Guide”.

Page 68: PRIMERGY RX100 S5 - Fujitsumanuals.ts.fujitsu.com/file/3934/rx100s5-ba-en.pdf · RX100 S5 Operating manual 7 1 Preface The PRIMERGY RX100 S5 server is an Intel-based server for small

68 Operating manual RX100 S5

Configuring the server Starting up and operation

5.3.2 Configuring the onboard SATA controller

A SATA controller is integrated on the system board. You can configure the onboard SATA controller either before or during ServerStart. Using ServerStart is recommended.

I The controller has its own configuration utility. More detailed information may be found in the “Embedded MegaRAID Software User’s Guide” manual (on the ServerBooks DVD under “Controllers”).

I Descriptions of operating systems not covered in the RAID controller manual are provided in the corresponding readme files on the driver CDs.

5.3.3 Configuring the onboard SAS controller with “Integrated Mirroring Enhanced”

The server has an onboard SAS controller with “Integrated Mirroring Enhanced” functionality. Optionally, you can configure the onboard SAS controller before or during ServerStart. Using ServerStart is recommended.

I The controller makes a separate utility available for IME configuration. For further information, refer to the “SAS/SATA Controller MegaRAID 1064 / 1068 / 1078 Installation Guide” on the ServerBooks DVD (select “Controllers” from the menu).

I Descriptions of operating systems not covered in the RAID controller manual are provided in the corresponding readme files on the driver CDs.

Page 69: PRIMERGY RX100 S5 - Fujitsumanuals.ts.fujitsu.com/file/3934/rx100s5-ba-en.pdf · RX100 S5 Operating manual 7 1 Preface The PRIMERGY RX100 S5 server is an Intel-based server for small

RX100 S5 Operating manual 69

Starting up and operation Configuring the server

5.3.4 Configuration with ServerStart

The ServerStart disc 1 supplied allows you to conveniently configure the server and install the operating system. The menu-assisted configuration includes the server configuration with SCU and the RAID controller configuration with ServerViewRAID.

The ServerStart advantages

– Automatic configuration of your server’s hardware and disk arrays.

– Installation assistance for all leading server operating systems.

– Creation of configuration files for unattended installation of several PRIMERGY servers with identical hardware configurations.

– Installation of drivers and additional software.

I The software that can be installed depends on your server’s hardware configuration. This configuration is detected automatically.

I Descriptions of operating systems not covered in the RAID controller manual are provided in the corresponding readme files on the driver CDs.

To find out how to operate ServerStart and for further information, refer to the associated manual.

If you are using ServerStart, you can skip the following section on how to configure the server and install the operating system. Continue from section “Cleaning the server” on page 70.

Page 70: PRIMERGY RX100 S5 - Fujitsumanuals.ts.fujitsu.com/file/3934/rx100s5-ba-en.pdf · RX100 S5 Operating manual 7 1 Preface The PRIMERGY RX100 S5 server is an Intel-based server for small

70 Operating manual RX100 S5

Cleaning the server Starting up and operation

5.3.5 Configuration without ServerStart

Configuring the onboard SATA controller

Configure the controller as described in section “Configuring the onboard SATA controller” on page 68.

Configuring the onboard SAS controller with “Integrated Mirroring Enhanced”

Configure the controller as described in section “Configuring the onboard SAS controller with “Integrated Mirroring Enhanced”” on page 68.

Installing the operating system

Ê Insert the CD/DVD for the operating system you want to install.

Ê Reboot the server.

Ê Follow the instructions on screen and in the manual for the operating system.

5.4 Cleaning the server

V CAUTION!

Switch the server off and disconnect the power plugs from the grounded shockproof sockets.

Do not clean any interior parts yourself; leave this job to a service technician.

Do not use any cleaning agents that contain abrasives or may corrode plastic.

Ensure that no liquid enters the system. Ensure that the ventilation areas of the server and the monitor are clear.

Clean the keyboard and the mouse with a disinfecting cloth.

Wipe the server and monitor casing with a dry cloth. If particularly dirty, use a cloth that has been moistened in a mild domestic detergent and then carefully wrung out.

Page 71: PRIMERGY RX100 S5 - Fujitsumanuals.ts.fujitsu.com/file/3934/rx100s5-ba-en.pdf · RX100 S5 Operating manual 7 1 Preface The PRIMERGY RX100 S5 server is an Intel-based server for small

RX100 S5 Operating manual 71

6 Property and data protectionThe lockable rack door protects the server against unauthorized access.

To protect your system and data internally against unauthorized access, you can activate the security functions using the BIOS Setup.

6.1 BIOS Setup security functions

The System Security menu in the BIOS Setup offers various options for protecting your data from unauthorized access. By combining these options you can achieve optimum protection for your system.

I A detailed description of the System Security menu and how to assign passwords can be found in the BIOS Setup documentation on the ServerBooks DVD.

Preventing unauthorized BIOS Setup calls

You can activate this protection by setting a supervisor password in the System Security menu.

Preventing unauthorized system access

You can activate this protection by setting a user password in the System Security menu.

Preventing unauthorized write access to hard disk drives

To activate this protection, go to the System Security menu under Hard Disk Drive and select the Write Protect All Sectors or Write Protect Boot Sector option.

Page 72: PRIMERGY RX100 S5 - Fujitsumanuals.ts.fujitsu.com/file/3934/rx100s5-ba-en.pdf · RX100 S5 Operating manual 7 1 Preface The PRIMERGY RX100 S5 server is an Intel-based server for small
Page 73: PRIMERGY RX100 S5 - Fujitsumanuals.ts.fujitsu.com/file/3934/rx100s5-ba-en.pdf · RX100 S5 Operating manual 7 1 Preface The PRIMERGY RX100 S5 server is an Intel-based server for small

RX100 S5 Operating manual 73

7 Troubleshooting and tipsV CAUTION!

Follow the safety instructions in the “Safety notes and other important information” manual and in chapter “Important information” on page 25.

If a fault occurs, attempt to resolve it using the measures described:

– in this chapter,– in the documentation for the connected devices,– in the help systems of the software used.

If you fail to correct the problem, proceed as follows:

Ê Make a list of the steps performed and the circumstances that led to the fault. Also make a list of any error messages that were displayed.

Ê Switch off the server.

Ê Contact our customer service team.

7.1 Power-on indicator remains unlit

The power-on indicator remains dark after you switch on your device.

Power cable incorrectly connected

Ê Make sure that the power cable is correctly connected to the server and to the power outlet on the rack's socket strip.

Power supply overloaded

Ê Disconnect the server power plug from the insulated socket.

Ê Wait a few seconds before you plug it into the insulated socket again.

Ê Switch on your server.

Page 74: PRIMERGY RX100 S5 - Fujitsumanuals.ts.fujitsu.com/file/3934/rx100s5-ba-en.pdf · RX100 S5 Operating manual 7 1 Preface The PRIMERGY RX100 S5 server is an Intel-based server for small

74 Operating manual RX100 S5

Server switches itself off Troubleshooting and tips

7.2 Server switches itself off

Server Management has detected an error

Ê Check the error list or the ErrorLog file in the ServerView program, and attempt to eliminate the error.

7.3 Screen remains blank

Monitor is switched off

Ê Switch on your monitor.

Screen has gone blank

Ê Press any key on the keyboard.

or

Ê Deactivate screen saver. Enter the appropriate password.

Brightness control is set to dark

Ê Set the brightness control on the monitor to light. For detailed information, refer to the operating manual supplied with your monitor.

Power cable or monitor cable not connected

Ê Switch off the monitor and the server.

Ê Check whether the power cable is properly connected to the monitor and to the grounded socket.

Ê Check whether the monitor cable is properly connected to the server and monitor (if it is plugged in with a connector). If a separate graphics card is installed in the server, then the monitor cable must be connected to the graphics card.

Ê Switch on the monitor and the server.

Page 75: PRIMERGY RX100 S5 - Fujitsumanuals.ts.fujitsu.com/file/3934/rx100s5-ba-en.pdf · RX100 S5 Operating manual 7 1 Preface The PRIMERGY RX100 S5 server is an Intel-based server for small

RX100 S5 Operating manual 75

Troubleshooting and tips Flickering stripes on monitor screen

7.4 Flickering stripes on monitor screen

V CAUTION!

Switch off the server immediately. Risk of damaging the server.

Monitor does not support the set horizontal frequency

Ê Find out which horizontal frequency your monitor screen supports. You will find the horizontal frequency (also known as line frequency or horizontal deflection frequency) in the documentation for your monitor.

Ê Refer to the documentation for your operating system or the software for the screen controller for details of how to set the correct horizontal frequency for your monitor, and follow the procedure accordingly.

7.5 No screen display or display drifts

The wrong horizontal frequency or resolution has been selected for the monitor or for the application program.

Ê Find out which horizontal frequency your monitor screen supports. You will find the horizontal frequency (also known as line frequency or horizontal deflection frequency) in the documentation for your monitor.

Ê Refer to the documentation for your operating system or the software for the screen controller for details of how to set the correct horizontal frequency for your monitor, and follow the procedure accordingly.

7.6 No mouse pointer displayed on screen

Mouse driver not loaded

Ê Check whether the mouse driver is properly installed and is activated when the application program is started. Detailed information can be found in the user manuals for the mouse, the operating system and the application program.

Page 76: PRIMERGY RX100 S5 - Fujitsumanuals.ts.fujitsu.com/file/3934/rx100s5-ba-en.pdf · RX100 S5 Operating manual 7 1 Preface The PRIMERGY RX100 S5 server is an Intel-based server for small

76 Operating manual RX100 S5

Incorrect date and time Troubleshooting and tips

Mouse controller disabled

The mouse controller on the system board must be enabled if you are using the mouse supplied.

Ê Check in the BIOS Setup that the mouse controller is Enabled.

7.7 Incorrect date and time

Ê Set the date and time in the operating system or in the BIOS Setup under the Main menu, using System Date and System Time respectively.

I Note that the operating system may affect the system time. For example, the operating system time may deviate from the system time under Linux, and would overwrite the system time in the default setting on shutdown.

If the date and time are still wrong after the server has been switched off and back on again, replace the lithium battery (for a description refer to the Technical Manual for the D2542 system board) or contact our customer service team.

7.8 System will not boot

The system will not boot after installing a new hard disk drive.

SAS configuration incorrect

Ê Check the settings for the hard disk drives (SAS Device Configuration) and the additional settings in the SAS configuration menu.

7.9 Error message on screen

The meaning of the error message is explained in the manual for the BIOS Setup and in the documentation for the relevant components and programs on the PRIMERGY ServerBooks DVD.

Page 77: PRIMERGY RX100 S5 - Fujitsumanuals.ts.fujitsu.com/file/3934/rx100s5-ba-en.pdf · RX100 S5 Operating manual 7 1 Preface The PRIMERGY RX100 S5 server is an Intel-based server for small

RX100 S5 Operating manual 77

8 CSS componentsThis chapter describes how to handle CSS components and how to identify defective CSS components and replace them yourself.

I Further information on the CSS concept is provided in the “Customer Self Service (CSS)” manual on the ServerBooks DVD.

Upgrades, updates and replacement of non-CSS components are described in the “Options Guide” or in the service supplement and may only be performed by authorized specialist personnel.

V CAUTION!

Follow the safety instructions in the chapter “Important information” on page 25.

Page 78: PRIMERGY RX100 S5 - Fujitsumanuals.ts.fujitsu.com/file/3934/rx100s5-ba-en.pdf · RX100 S5 Operating manual 7 1 Preface The PRIMERGY RX100 S5 server is an Intel-based server for small

78 Operating manual RX100 S5

Hot-plug HDD modules CSS components

8.1 Hot-plug HDD modules

I If your server is a version with EasyChange hard disk drives, this section does not apply to you.

A maximum of two SAS or SATA HDD modules can be installed in the PRIMERGY RX100 S5 server.

The hard disk drives which can be ordered for the PRIMERGY RX100 S5 are supplied already mounted in an installation frame so that defective hard disk drives can be replaced and new drives can be added during operation. The hard disk drive and installation frame together make up the HDD module.

V CAUTION!

● The hard disk drive may not be removed from the installation frame by anyone except a service technician.

● The HDD modules (drives) must all be marked clearly so that they can be put back in their original places after an upgrade. If this is not done, existing data can be lost.

● The hot-plug function is only possible in conjunction with a corre-sponding RAID configuration.

Further information about the RAID configuration or RAID level can be found in the RAID controller documentation.

Page 79: PRIMERGY RX100 S5 - Fujitsumanuals.ts.fujitsu.com/file/3934/rx100s5-ba-en.pdf · RX100 S5 Operating manual 7 1 Preface The PRIMERGY RX100 S5 server is an Intel-based server for small

RX100 S5 Operating manual 79

CSS components Hot-plug HDD modules

8.1.1 HDD module and dummy module

The hard disk drives which can be ordered for the PRIMERGY RX100 S5 are supplied already mounted in an installation frame so that defective drives can be replaced and new drives can be added during operation. The hard disk drive and installation frame together make up the HDD module.

Figure 16: HDD module and dummy module

1 HDD module (installation frame with hard disk drive installed)

2 IndicatorsHDD Busy (LED green)HDD Fault (LED orange)For description see section “Indicators on the hot-plug HDD module” on page 60.

3 Handle for locking and unlocking the HDD module

4 Button for locking and unlocking the handle

5 Ridge for applying a sticker with the current drive name

6 Dummy module

7 Tabs for unlocking the dummy module

1 6 75

4

32 4

Page 80: PRIMERGY RX100 S5 - Fujitsumanuals.ts.fujitsu.com/file/3934/rx100s5-ba-en.pdf · RX100 S5 Operating manual 7 1 Preface The PRIMERGY RX100 S5 server is an Intel-based server for small

80 Operating manual RX100 S5

Hot-plug HDD modules CSS components

8.1.2 Handling hard disk drives and HDD modules

Hard disk drives incorporated in the HDD modules are highly sensitive electro-magnetic devices and must be handled with great care. Incorrect handling can cause partial or total failure of the hard disk drives. These failures can result in data errors and to a loss of data or to total corruption of the hard disk drive.

Observe the following rules to prevent such problems occurring:

● Only store and transport HDD modules within the limits stipulated in the specification.

● When transporting HDD modules (even over short distances), always use the original packaging (ESD label).

● Never expose HDD modules to a temperature shock. Avoid the formation of condensation inside and on the outside of the hard disk drive.

V CAUTION!

The HDD module must be acclimatized in its operating environment for an acclimatization time before it is started up for the first time.

● Always set the HDD module down carefully, with the large surface facing downwards to prevent it from tipping over.

Temperature difference (°C)(operating environment/

outside)

Minimum acclimatization time (hours)

5 3

10 5

15 7

20 8

25 9

30 10

Table 2: Acclimatization times for HDD modules

Page 81: PRIMERGY RX100 S5 - Fujitsumanuals.ts.fujitsu.com/file/3934/rx100s5-ba-en.pdf · RX100 S5 Operating manual 7 1 Preface The PRIMERGY RX100 S5 server is an Intel-based server for small

RX100 S5 Operating manual 81

CSS components Hot-plug HDD modules

8.1.3 Removing/installing the dummy module

Free slots are provided with dummy modules. Remove the dummy module before installing an additional HDD module.

Figure 17: Removing/installing the dummy module

Ê Press both tabs on the dummy module together until the locking mechanism disengages (1).

Ê Pull the dummy module out of the bay (2).

To install a dummy module, follow the same procedure in reverse order.

V CAUTION!

Store the dummy module in a safe place. If you have removed a HDD module and do not install a new one in its place, put the dummy module back in its place for cooling, to comply with EMC regulations (regulations regarding electromagnetic compatibility), and for protection against fire. Ensure that the dummy module engages correctly in the bay.

1

1

2

Page 82: PRIMERGY RX100 S5 - Fujitsumanuals.ts.fujitsu.com/file/3934/rx100s5-ba-en.pdf · RX100 S5 Operating manual 7 1 Preface The PRIMERGY RX100 S5 server is an Intel-based server for small

82 Operating manual RX100 S5

Hot-plug HDD modules CSS components

8.1.4 Installing the HDD module

Removing the transport lock

I If HDD modules are provided with a transport lock, remove the lock before releasing the locking mechanism.

Figure 18: Removing the transport lock

Ê Pull the transport lock out in the direction of the arrow.

Page 83: PRIMERGY RX100 S5 - Fujitsumanuals.ts.fujitsu.com/file/3934/rx100s5-ba-en.pdf · RX100 S5 Operating manual 7 1 Preface The PRIMERGY RX100 S5 server is an Intel-based server for small

RX100 S5 Operating manual 83

CSS components Hot-plug HDD modules

Unlocking the HDD module

Figure 19: Unlocking the HDD module

Ê Release the locking mechanism by pressing the locking button (1).

Ê Push the handle of the HDD module fully in the direction of the arrow (2).

The HDD module is now unlocked.

1

2

Page 84: PRIMERGY RX100 S5 - Fujitsumanuals.ts.fujitsu.com/file/3934/rx100s5-ba-en.pdf · RX100 S5 Operating manual 7 1 Preface The PRIMERGY RX100 S5 server is an Intel-based server for small

84 Operating manual RX100 S5

Hot-plug HDD modules CSS components

Installing the HDD module

Figure 20: Installing the HDD module

Ê Unlock the HDD module as described in section “Removing the transport lock” on page 82.

Ê Carefully push the HDD module into the empty slot (1) until it stops.

Ê Push the handle of the HDD module as far as it will go in the direction of the arrow (2) until the locking mechanism is engaged.

1

2

Page 85: PRIMERGY RX100 S5 - Fujitsumanuals.ts.fujitsu.com/file/3934/rx100s5-ba-en.pdf · RX100 S5 Operating manual 7 1 Preface The PRIMERGY RX100 S5 server is an Intel-based server for small

RX100 S5 Operating manual 85

CSS components Hot-plug HDD modules

8.1.5 Removing the HDD module

V CAUTION!

● Only remove an HDD module during operation if the drive is not currently being accessed. Observe the control LEDs for the corre-sponding HDD modules (see “Indicators on the hot-plug HDD module” on page 60).

● Under no circumstances should you remove an HDD module while the system is in operation if you are not sure whether the hard disk drive is operated by a RAID controller and belongs to a disk array which is operating at RAID level 1.

A HDD module can only be replaced during operation in conjunction with a corresponding RAID configuration.

● All HDD modules (drives) must be uniquely identified so that they can be reinstalled in their original mounting locations later. If this is not done, existing data can be lost.

If you want to remove a HDD module during operation, proceed as follows:

Ê If you want to remove a HDD module that is not defective, the drive must be first set to "Offline" via the software (RAID controller configuration software).

Ê Unlock the HDD module as described in section “Removing the transport lock” on page 82.

Ê Pull the HDD module out a few centimeters.

Ê Wait for at least 60 seconds.

I This period is necessary for the RAID controller to recognize that a HDD module has been removed and for the hard disk drive to come to a stop.

Ê Pull the HDD module out completely.

Page 86: PRIMERGY RX100 S5 - Fujitsumanuals.ts.fujitsu.com/file/3934/rx100s5-ba-en.pdf · RX100 S5 Operating manual 7 1 Preface The PRIMERGY RX100 S5 server is an Intel-based server for small

86 Operating manual RX100 S5

Hot-plug HDD modules CSS components

Ê Install the new HDD module, as described in “Installing the HDD module” on page 82.

V CAUTION!

If you have removed a HDD module and do not install a new one in its place, put the dummy module back in its place for cooling, to comply with EMC regulations (regulations regarding electromagnetic compatibility), and for protection against fire. Ensure that the dummy module engages correctly in the bay.

Page 87: PRIMERGY RX100 S5 - Fujitsumanuals.ts.fujitsu.com/file/3934/rx100s5-ba-en.pdf · RX100 S5 Operating manual 7 1 Preface The PRIMERGY RX100 S5 server is an Intel-based server for small

RX100 S5 Operating manual 87

CSS components Replacement of non-hot-plug components

8.2 Replacement of non-hot-plug components

When a defective non-hot-plug component has been detected (see page 58 or page 62), proceed as follows:

Ê Exit all applications and shut down the server properly (see section “Switching the server on and off” on page 65).

Ê Pull all power plugs out of the insulated sockets of the rack's internal power supply.

Ê Remove the server from the rack (see section “Installing/removing the server in/from the rack” on page 41) and put the server on a table, for example.

8.2.1 Opening the server and identifying the defective CSS component

Figure 21: Loosening the knurled screw

Ê Unlock the top cover, by loosening the knurled screw on the rear panel (1).

1

Page 88: PRIMERGY RX100 S5 - Fujitsumanuals.ts.fujitsu.com/file/3934/rx100s5-ba-en.pdf · RX100 S5 Operating manual 7 1 Preface The PRIMERGY RX100 S5 server is an Intel-based server for small

88 Operating manual RX100 S5

Replacement of non-hot-plug components CSS components

Figure 22: Removing the top cover

Ê Push the top cover as far as it will go in the direction of the arrow (1).

Ê Lift off the top cover upwards (2).

Ê Press the Indicate CSS button on the system board (see the technical manual for the system board D2542 on the ServerBooks DVD).

The PRIMERGY Diagnostic LED of the defective CSS component lights up orange and displays, which CSS component on the system board needs replacing (memory module, fan or expansion card).

2

1

Page 89: PRIMERGY RX100 S5 - Fujitsumanuals.ts.fujitsu.com/file/3934/rx100s5-ba-en.pdf · RX100 S5 Operating manual 7 1 Preface The PRIMERGY RX100 S5 server is an Intel-based server for small

RX100 S5 Operating manual 89

CSS components Replacement of non-hot-plug components

8.2.2 Replacing a memory module

8.2.2.1 Removing a defective memory module

Figure 23: Removing a memory module

Ê Fold the tabs outwards on both sides of the relevant slot (1).

Ê Pull the defective memory module out of the slot (2).

1

1

2

Page 90: PRIMERGY RX100 S5 - Fujitsumanuals.ts.fujitsu.com/file/3934/rx100s5-ba-en.pdf · RX100 S5 Operating manual 7 1 Preface The PRIMERGY RX100 S5 server is an Intel-based server for small

90 Operating manual RX100 S5

Replacement of non-hot-plug components CSS components

8.2.2.2 Installing a new memory module

V CAUTION!

Please note the equipping rules in the tecnical manual for the system board D2542.

Figure 24: Installing a memory module

Ê Carefully press the memory module into the slot (1) until the fastening tabs on both sides of it engage (2).

2

2

1

Page 91: PRIMERGY RX100 S5 - Fujitsumanuals.ts.fujitsu.com/file/3934/rx100s5-ba-en.pdf · RX100 S5 Operating manual 7 1 Preface The PRIMERGY RX100 S5 server is an Intel-based server for small

RX100 S5 Operating manual 91

CSS components Replacement of non-hot-plug components

8.2.3 Replacing a system fan

V CAUTION!

Since the system fans are not redundant, defective system fans have to be replaced immediately.

Figure 25: Example: removing system fan 5 (FAN 5)

Ê Lift off the system fan upwards (1).

To do this, press up the four rubber pins (a).

1

a

a

a

a

Page 92: PRIMERGY RX100 S5 - Fujitsumanuals.ts.fujitsu.com/file/3934/rx100s5-ba-en.pdf · RX100 S5 Operating manual 7 1 Preface The PRIMERGY RX100 S5 server is an Intel-based server for small

92 Operating manual RX100 S5

Replacement of non-hot-plug components CSS components

Figure 26: System fans 1-5

Ê Remove the system fan cable from the corresponding cable clamps.

Ê Remove the system fan cable of the defective system fan from the corre-sponding plug on the system board (see the tecnical manual for the system board D2542).

5 4 3 2 1

Page 93: PRIMERGY RX100 S5 - Fujitsumanuals.ts.fujitsu.com/file/3934/rx100s5-ba-en.pdf · RX100 S5 Operating manual 7 1 Preface The PRIMERGY RX100 S5 server is an Intel-based server for small

RX100 S5 Operating manual 93

CSS components Replacement of non-hot-plug components

Figure 27: Example: installing system fan 5 (FAN 5)

Ê Install the new system fan (1).

Make sure that the air flow aims at the system board. The arrow (a) indicates the direction of the air flow from the system fan.

Ê Press the four rubber pins, until they engage (2).

1

1

22

22

a

Page 94: PRIMERGY RX100 S5 - Fujitsumanuals.ts.fujitsu.com/file/3934/rx100s5-ba-en.pdf · RX100 S5 Operating manual 7 1 Preface The PRIMERGY RX100 S5 server is an Intel-based server for small

94 Operating manual RX100 S5

Replacement of non-hot-plug components CSS components

Figure 28: System fans 1-5

Ê Route the system fan cable with the aid of the cable clamps.

Ê Connect the system fan cable of the new system fan to the corresponding plug on the system board (see the tecnical manual for the system board D2542).

5 4 3 2 1

Page 95: PRIMERGY RX100 S5 - Fujitsumanuals.ts.fujitsu.com/file/3934/rx100s5-ba-en.pdf · RX100 S5 Operating manual 7 1 Preface The PRIMERGY RX100 S5 server is an Intel-based server for small

RX100 S5 Operating manual 95

CSS components Replacement of non-hot-plug components

8.2.4 Replacing an expansion card

8.2.4.1 Removing a riser module

Figure 29: Removing a riser module

Ê Remove the cables from the defective expansion card.

Ê Undo the two knurled screws (1).

Ê Carefully pull out the riser module upwards (2).

2

1 1

Page 96: PRIMERGY RX100 S5 - Fujitsumanuals.ts.fujitsu.com/file/3934/rx100s5-ba-en.pdf · RX100 S5 Operating manual 7 1 Preface The PRIMERGY RX100 S5 server is an Intel-based server for small

96 Operating manual RX100 S5

Replacement of non-hot-plug components CSS components

8.2.4.2 Removing a defective expansion card

Figure 30: Removing a defective expansion card

Ê Pull out the defective expansion card from the riser card slot.

Page 97: PRIMERGY RX100 S5 - Fujitsumanuals.ts.fujitsu.com/file/3934/rx100s5-ba-en.pdf · RX100 S5 Operating manual 7 1 Preface The PRIMERGY RX100 S5 server is an Intel-based server for small

RX100 S5 Operating manual 97

CSS components Replacement of non-hot-plug components

8.2.4.3 Installing a new expansion card

Figure 31: Installing a new expansion card

Ê Carefully press the new expansion card into the riser card slot (a), until it clicks into place (1).

Make sure that the lug on the slot cover clicks into place in the corre-sponding hole (2).

a

1

2

Page 98: PRIMERGY RX100 S5 - Fujitsumanuals.ts.fujitsu.com/file/3934/rx100s5-ba-en.pdf · RX100 S5 Operating manual 7 1 Preface The PRIMERGY RX100 S5 server is an Intel-based server for small

98 Operating manual RX100 S5

Replacement of non-hot-plug components CSS components

8.2.4.4 Installing a riser module

Figure 32: Installing a riser module

Ê Insert the riser card into the system board slot (1).

Make sure that the pins of the riser holder fit into the corresponding openings (2).

1

1

2 2

2

2

Page 99: PRIMERGY RX100 S5 - Fujitsumanuals.ts.fujitsu.com/file/3934/rx100s5-ba-en.pdf · RX100 S5 Operating manual 7 1 Preface The PRIMERGY RX100 S5 server is an Intel-based server for small

RX100 S5 Operating manual 99

CSS components Replacement of non-hot-plug components

Figure 33: Securing the riser module

Ê Secure the riser module using the two knurled screws (1).

Ê Connect the cables to the expansion card.

2

1 1

Page 100: PRIMERGY RX100 S5 - Fujitsumanuals.ts.fujitsu.com/file/3934/rx100s5-ba-en.pdf · RX100 S5 Operating manual 7 1 Preface The PRIMERGY RX100 S5 server is an Intel-based server for small

100 Operating manual RX100 S5

Replacement of non-hot-plug components CSS components

8.2.5 Assembling the server

Figure 34: Mounting the top cover

Ê Place the top cover on the server (1).

Make sure that each bolt is positioned in the corresponding nut.

Ê Push the top cover as far as it will go in the direction of the arrow (2).

Figure 35: Securing the knurled screw

Ê Secure the top cover with the knurled screw on the rear panel (1).

2

111

1

Page 101: PRIMERGY RX100 S5 - Fujitsumanuals.ts.fujitsu.com/file/3934/rx100s5-ba-en.pdf · RX100 S5 Operating manual 7 1 Preface The PRIMERGY RX100 S5 server is an Intel-based server for small

RX100 S5 Operating manual 101

Index

3rd party rackinstalling in 48requirements 43

Aaccessible drives 13acclimatization time 39, 80Advanced Video Redirection 15ambient conditions 22articulated cable guide 47ASR&R 14availability 14AVR 15

BBIOS update 17BIOS, security functions 71

Ccables

connecting 54disconnecting 54

CE marking 21, 32Class A Compliance Statement 33cleaning

keyboard 70monitor 70mouse 70server 70

componentshardware 7software 7

configuration, server 67connecting

cables 54external devices 54

connection panel 51consumables 36control panel 55controls 55

correcting faults 73

Ddata manipulation 7data protection 71data security 14DataCenter Rack, requirements 42date, incorrect 76delivery note 23, 40devices, connecting to server 51disconnecting, cables 54disposal, devices 37dummy module, HDD module 81, 86DVD drive 13DVD drive activity, indicator 59

EECC 14electrical data 20electromagnetic compatibility 21, 32electrostatic-sensitive devices

(ESD) 31EMC directive 21EMC regulations 81, 86environment class 22environmental protection 36error

drifting display on monitor 75incorrect date 76incorrect time 76no display on monitor 75no mouse pointer 75power-on indicator does not

light 73screen remains blank 74screen shows flickering

stripes 75server switches itself off 74system does not boot 76

Error Correcting Code 14error message on screen 76

Page 102: PRIMERGY RX100 S5 - Fujitsumanuals.ts.fujitsu.com/file/3934/rx100s5-ba-en.pdf · RX100 S5 Operating manual 7 1 Preface The PRIMERGY RX100 S5 server is an Intel-based server for small

102 Operating manual RX100 S5

Index

ESD (electrostatic-sensitive devices) 31

external devices, connecting 54

Ffault

drifting display on monitor 75incorrect date 76incorrect time 76no display on monitor 75screen remains blank 74screen shows flickering

stripes 75system does not boot 76

FCC statement 33features 10flash EPROM 17

GGlobal Error indicator 58, 61graphics card 52

Hhard disk activity, indicator 57hard disk drive 12

handling 80installation frame 78, 79

hard disk write cache 67HDD module 78, 79

acclimatization time 39, 80indicators 60installation frame 82installing 82

IID button 56ID indicator 57IME (Integrated Mirroring

Enhanced) 68indicators

DVD drive activity 59Global Error 58, 61hard disk activity 57hot-plug HDD module 60

ID 57LAN activity 64LAN transfer rate 64on server 55operating 57ServerView Local Service

Panel 59information material, additional 9installation

ports 51installation, server 49installing in

3rd party rack 48PRIMECENTER Rack 45

installing, server 41Integrated Mirroring Enhanced

RAID functionality 13Integrated Mirroring Enhanced

(IME) 68integrated Remote Management

Controller 15iRMC S2 15

Kkeyboard port 52

Llabels 37LAN activity, indicator 64LAN port 52LAN transfer rate, indicator 64laser information 30light emitting diode (LED) 30lithium battery 29Low Voltage Directive 21, 32

Mmain memory 89mains voltage, connecting server 53meaning of the symbols 19monitor

display drifts 75no display 75

monitor port 52

Page 103: PRIMERGY RX100 S5 - Fujitsumanuals.ts.fujitsu.com/file/3934/rx100s5-ba-en.pdf · RX100 S5 Operating manual 7 1 Preface The PRIMERGY RX100 S5 server is an Intel-based server for small

RX100 S5 Operating manual 103

Index

mouse port 52mouse, no mouse pointer on

screen 75

NNMI button 56noise level 22notational conventions 19

OOn/Off button 56onboard SAS controller 14

configuring 70onboard SATA controller 13, 68

configuring 70operating system, installing 70operation 55overload 16

Ppackaging 36, 40PDA 14, 16ports 51

keyboard port 52LAN 52monitor 52mouse port 52serial port 52service LAN 52USB 52

power-on indicator 57does not light 73

PRIMECENTER Rackinstalling in 45

PRIMECENTER rackrequirements 42

property protection 71PS/2 keyboard port 52PS/2 mouse port 52

RRAID configuration 68RAID controller 14RAID functionality 13, 68

RAID level 14rating plate 40recycling devices 37regulations and standards 21Remote Storage 15removing, server 41requirements

3rd party rack 43DataCenter Rack 42PRIMECENTER rack 42

reset button 56return of devices 37routing

cables 47

Ssafety instructions 25safety standards 21SAS controller

IME configuration 68Integrated Mirroring

Enhanced 13RAID configuration 68

SATA RAID controller 13, 68saving energy 36screen

error message 76flickering 75remains blank 74shows flickering stripes 75

security function 7security functions

setup password 71system password 71

serial port 52server

ambient conditions 22configuration 16, 67connecting external devices 51connecting mains voltage 53control panel 55correcting faults 73data protection 71dimensions 22

Page 104: PRIMERGY RX100 S5 - Fujitsumanuals.ts.fujitsu.com/file/3934/rx100s5-ba-en.pdf · RX100 S5 Operating manual 7 1 Preface The PRIMERGY RX100 S5 server is an Intel-based server for small

104 Operating manual RX100 S5

Index

electrical data 20fitting in rack 41indicators 55installation 49installing 41NMI button 56noise level 22operation 55ports 51property protection 71removing 41reset button 56routing cables 47safety standards 20starting up 55switches itself off (error) 74switching off 65switching on 65technical data 20transport 34troubleshooting 73unpacking 40ventilation clearance 22weight 22

server management 16ServerStart 16, 69ServerView 16

supported functions 16ServerView Local Service

Display 13ServerView Local Service Panel 59ServerView Remote

Management 17, 18service LAN port 15, 52setup password 71support bracket 45switch off time, defining 66switch on time, defining 66switching off, server 65switching on, server 65system board 11system does not boot 76system fan 91system password 71

Ttarget group 7technical data 20telescopic rail 47time, incorrect 76tips 73transport damage 23, 40transporting the server 34troubleshooting 73troubleshooting, server 73

Uunpacking, server 40USB port 52

Vventilation clearance 22

Wweight 22write cache, enable 67