PRIMERGY TX150 S7System configurator and order-information guide
Contents
Instructions
Configuration diagram
ConfiguratorSoftware Configurator 32-bit and 64-bit
I Basic unit
II Processor
III Memory
IV Graphics
V Energy Star restrictions
VI Accessible drives
VII Hard disk drives
VIII SAS / SCSI Controller
IX Disk array
X Communication/Network
XI System management options
XII Miscellaneous
XIII Country specific power cords
Change report
PRIMERGY Server
August 2013
System configurator and order-information guidePRIMERGY TX150 S7 Status 2013-07-31
Instructions
This document contains basic product and configuration information that will enable you to configure your system viaPC-/ System-Architect.
Only these tools will ensure a fast and proper configuration of your PRIMERGY server or your complete PRIMERGY Rack system.
You can configure your individual PRIMERGY server in order to adjust your specific requirements.
The System configurator is divided into several chapters that are identical to the current price list and PC-/ System-Architect
Please follow the lines. If there is a junction, you can choose which way or component you would like to take. Go through the configurator by following the lines from the top to the bottom.
Section III Memory, example
There are X memory slots which can be equipped with XXX MB.
It is permissible to make up to X passes through the memory upgrade options.
S26361-XXX-XXX S26361-XXX-XXX
Memory XXX MB Memory XXX MB
X times
max. X times per system max. X times per system
In one chapter you can only select as many components (here 4x) as the arrow indicates. 4x
Please note that there are information symbols which indicate necessary information.
Further information in the internet see:
http://ts.fujitsu.com/products/standard_servers/index.html (internet)
https://partners.ts.fujitsu.com/com/order-supply/configurators/primergy_config/current/Pages/default.aspx (extranet)
Prices and availability see price list and PC-/ System-ArchitectSubject to change and errors excepted
Fujitsu Technology Solutions x86 PRIMERGY Server 2 of 21
http://www.primergy.com/http://extranet.fujitsu-siemens.com/primergy
System configurator and order-information guidePRIMERGY TX150 S7 Status 2013-07-31
Configuration diagram PRIMERGY TX150 S7 SATA LFF (3.5") System Unit
System unit ( I )
SIDE VIEW FRONT VIEW
3 x HH 5.25" free or 2 x HH 5,25" free + Option A
or PS (I)
1. PSU 2. PSU 5.25" x 1.6" Redundant power supply option
5.25" x 1.6"Processor ( II )
5.25" Slim Line
I / A I / B Accessible drives ( V )
II / A II / B
III / A III / B Mounting Kit DVD(sl) + LSP/LSD: (Option A)
- support for SL (0.5") DVD Drive + LSP /LPD
Memory ( III ) (Local Service Panel / Local Service Display)
each Clarkdale CPU offers 2 Banks (I, II) with 2 Channels each - occupies one 5.25" bay
each Lynnfield CPU offers 3 Banks (I, II, III) with 2 Channels each
one DVD (slim line or standard) is mandatoryExtension slots
SAS Controller ( VII )
Disk Array ( VIII )Communication/Network ( IX ) Hard disk drives ( VI )Miscellaneous ( X )
Slot 6 ( 3,3V ): PCIe x8, shortlp ready
Slot 5 ( 3,3V ): PCIe x8, short
Slot 4 ( 3,3V ): PCIe x4 (wired x1), shortnotched, possible to plug x8cards; lp ready
Slot 3 ( 3,3V ): PCIe x4 (wired x1), shortnotched, possible to plug x8cards;
Slot 2 ( 3,3V ): PCIe x8 (wired x4), longlp ready
Slot 1 ( 5V ): PCI 32-Bit / 33MHz, long
Key: A PCIe x4 card can also be plugged in a PCIe x8 slot
Included in basic unit A PCIe x8 card can be plugged in the notched slots no. 3 and 4
Option PCI and PCI-X slots are mechanically not compatible to PCIe slots!
4.)
ma
x.
6 P
CI-
Bu
ss
es
Standard Power Supply
3.5"x1" SATA
3.5"x1" SATA
3.5"x1" SATA
3.5"x1" SATA
Intel CPU
(Dual-or Quad Core)LSP/LSD Option
6.)
Sy
ste
m F
an
4x 3
,5"
HD
D F
ram
e
5.)
1.)
3.)
2.)
Fujitsu Technology Solutions x86 PRIMERGY Server 3 of 21
System configurator and order-information guidePRIMERGY TX150 S7 Status 2013-07-31
Configuration diagram PRIMERGY TX150 S7 SAS LFF (3.5") System Unit
System unit ( I )
SIDE VIEW FRONT VIEW
3 x HH 5.25" free or 2 x HH 5,25" free + Option A
or PS (I)
1. PSU 2. PSU 5.25" x 1.6" Redundant power supply option
5.25" x 1.6"Processor ( II )
5.25" Slim Line
I / A I / B Accessible drives ( V )
II / A II / B
III / A III / B Mounting Kit DVD(sl) + LSP/LSD: (Option A)
- support for SL (0.5") DVD Drive + LSP /LPD
Memory ( III ) (Local Service Panel / Local Service Display)
each Clarkdale CPU offers 2 Banks (I, II) with 2 Channels each - occupies one 5.25" bay
each Lynnfield CPU offers 3 Banks (I, II, III) with 2 Channels each
one DVD (slim line or standard) is mandatoryExtension slots
SAS Controller ( VII )
Disk Array ( VIII )Communication/Network ( IX ) Hard disk drives ( VI )Miscellaneous ( X )
Slot 6 ( 3,3V ): PCIe x8, shortlp ready
Slot 5 ( 3,3V ): PCIe x8, short
Slot 4 ( 3,3V ): PCIe x4 (wired x1), shortnotched, possible to plug x8cards; lp ready
Slot 3 ( 3,3V ): PCIe x4 (wired x1), shortnotched, possible to plug x8cards;
Slot 2 ( 3,3V ): PCIe x8 (wired x4), longlp ready
A mix of SAS and Eco SATA HDDs is not allowed!
Slot 1 ( 5V ): PCI 32-Bit / 33MHz, long
Key: A PCIe x4 card can also be plugged in a PCIe x8 slot
Included in basic unit A PCIe x8 card can be plugged in the notched slots no. 3 and 4
Option PCI and PCI-X slots are mechanically not compatible to PCIe slots!
4.)
1.)
3.)
2.)
6.)
Sy
ste
m F
an
ma
x.
6 P
CI-
Bu
ss
es
5.)
Standard Power Supply
3.5"x1" SAS / SATA
3.5"x1" SAS / SATA
3.5"x1" SAS / SATA
3.5"x1" SAS / SATA
4x 3
,5"
HD
D F
ram
e
Intel CPU
(Dual-or Quad Core)LSP/LSD Option
Fujitsu Technology Solutions x86 PRIMERGY Server 4 of 21
System configurator and order-information guidePRIMERGY TX150 S7 Status 2013-07-31
Configuration diagram PRIMERGY TX150 S7 SAS / SATA SFF (2.5") System Unit
System unit ( I )
SIDE VIEW FRONT VIEW
3 x HH 5.25" free or 2 x HH 5,25" free + Option A
or PS (I)
1. PSU 2. PSU 5.25" x 1.6" Redundant power supply option
5.25" x 1.6"Processor ( II )
5.25" Slim Line
I / A I / B Accessible drives ( V )
II / A II / B
III / A III / B Mounting Kit DVD(sl) + LSP/LSD: (Option A)
- support for SL (0.5") DVD Drive + LSP /LPD
Memory ( III ) (Local Service Panel / Local Service Display)
each Clarkdale CPU offers 2 Banks (I, II) with 2 Channels each - occupies one 5.25" bay
each Lynnfield CPU offers 3 Banks (I, II, III) with 2 Channels each
Extension slots one DVD (slim line or standard) is mandatory
SAS Controller ( VII )
Disk Array ( VIII )Communication/Network ( IX ) Hard disk drives ( VI )Miscellaneous ( X )
Slot 6 ( 3,3V ): PCIe x8, shortlp ready
Slot 5 ( 3,3V ): PCIe x8, short
Slot 4 ( 3,3V ): PCIe x4 (wired x1), shortnotched, possible to plug x8cards; lp ready
Slot 3 ( 3,3V ): PCIe x4 (wired x1), shortnotched, possible to plug x8cards;
Slot 2 ( 3,3V ): PCIe x8 (wired x4), longlp ready
A mix of SAS and SATA is not allowed!
Slot 1 ( 5V ): PCI 32-Bit / 33MHz, long
Key: A PCIe x4 card can also be plugged in a PCIe x8 slot
Included in basic unit A PCIe x8 card can be plugged in the notched slots no. 3 and 4
Option PCI and PCI-X slots are mechanically not compatible to PCIe slots!
3.)
1.)
LSP/LSD Option
ma
x.
6 P
CI-
Bu
ss
es
4.)
2.)
6.)
Sy
ste
m F
an
Standard Power Supply
5.)
Intel CPU
(Dual-or Quad Core)
8x SFF HDD Frame
2.5" (SFF) SAS / SATA
2.5" (SFF) SAS / SATA
2.5" (SFF) SAS / SATA
2.5" (SFF) SAS / SATA
2.5" (SFF) SAS / SATA
2.5" (SFF) SAS / SATA
2.5" (SFF) SAS / SATA
2.5" (SFF) SAS / SATA
Fujitsu Technology Solutions x86 PRIMERGY Server 5 of 21
System configurator and order-information guideStart PRIMERGY TX150 S7 PRIMERGY TX150 S7 Status 2013-07-31
SW Configurator IA32
with OEM-Software without OEM-Software
for PRIMERGY Server for PRIMERGY Server
OEM-SW is bound to HW and
is not allowed to be ordered
separately.
For all SW products please refer to the corresponding software configurator accessible via
the Extranet under Configuration & Tools, -All configurations, -Software, URL see below.
Microsoft - Software: **) PRIMECLUSTER *)
- Small Business Server 2003 - Clustering
- Windows Server 2003 R2, - Load Balancing
Standard Edition
Enterprise Edition
! Web Edition, SP2/English
- Additional loose Linux - Software: **)
Client-Access-Licenses (CALs) - Open Enterprise Server ***)
(not for Web Edition) - SuSE Linux ES (OEM): LO
- SuSE Linux ES (Support): LS
- Red Hat EL (O