PROCESS OPTIMIZATION USING

SPECTROPHOTOMETERS

www.zapstechnologies.com

By Bud Dunbar

ZAPS Technologies

617-448-0440

[email protected]

1

Page 2: PROCESS OPTIMIZATION USING SPECTROPHOTOMETERS

2

Page 3: PROCESS OPTIMIZATION USING SPECTROPHOTOMETERS

3

WHAT’S CHANGED?

• INEXPENSIVE & POWERFUL PHOTON COMPONENTS

• POWERFUL COMPUTERS

• ANALYTICAL ALGORITHMS

WHAT’S POSSIBLE

• COMPLETE SET OF PARAMETERS EVERY 2 MINUTES

• PROCESS OPTIMIZATION

Page 4: PROCESS OPTIMIZATION USING SPECTROPHOTOMETERS

4

Page 5: PROCESS OPTIMIZATION USING SPECTROPHOTOMETERS

5

Absorbance vs Wavelength

Potassium Permanganate (KMn04)– Sample 1 had a higher concentration than Sample 2

02/04/2014 © ZAPS Technologies, Inc.

Page 6: PROCESS OPTIMIZATION USING SPECTROPHOTOMETERS

6

• Multiple parameters at once

• Direct measurements

• In the natural matrix

• No reagents, no labor, no delay

• Much easier to maintain than in tank probes

• Self cleaning

• Self calibrating

• Digital, online, real time

• Highly accurate

SPECTROPHOTOMETRY ENABLES:

Page 7: PROCESS OPTIMIZATION USING SPECTROPHOTOMETERS

7

WASTEWATER DRINKING WATERBOD Biochemical Oxygen Demand BOD Biochemical Oxygen Demand

CBOD Carbonaceous BOD CHLa Chlorophyll-a

COD Chemical Oxygen Demand CHLb Chlorophyll-b

ECOLI Fecal Contamination CHLORINE Total Free Chlorine

FDOM Fluorescent Dissolved Organic COLOR Color

NH3 Ammonia ECOLI Fecal Contamination

NO3 Nirate+Nitrite FDOM Fluorescent Dissolved Organic

T Temperature NH3 Ammonia

TKN Total Kjeldahl Nitrogen NO3 Nirate+Nitrite

TOC Total Organic Carbon OIL Refined Hydrocarbons

TSS Total Suspended Solids PHYCO Phycobilin Chromophore

UVA UV 254 Absorbance RHO Rhodamine

UVT UV 254 Transmission SIZE Relative Particle Size

VFA Volatile Fatty Acids SUVA Specific UV Absorption

T Temperature

TKN Total Kjeldahl Nitrogen

TOC Total Organic Carbon

DO NOT SEE: TOX Disinfection Byproducts

Phosphorus TSS Total Suspended Solids

Disolved Oxygen TURB Turbidity (ATU)

PH UVA UV 254 AbsorbanceORP UVT UV 254 Transmission

Page 8: PROCESS OPTIMIZATION USING SPECTROPHOTOMETERS

Measure several properties of light ◦ Absorbance,

◦ Florescence,

◦ Reflectivity or Scattering

Looking at very specific outgoing and incoming

frequencies across a wide spectrum of

frequencies

Characterize normal underlying water matrix

Using high energy photons

Very sophisticated algorithms eliminate/separate

noise, tss, turbidity, temperature, pressure, etc

8

Page 9: PROCESS OPTIMIZATION USING SPECTROPHOTOMETERS

9

An implementation:

ZAPS

Page 10: PROCESS OPTIMIZATION USING SPECTROPHOTOMETERS

10

Secure Data Options • Cellular uplink • Ethernet connection (VPN) • 4-20mA • Digital connection to:

• SCADA or • PLC

Page 11: PROCESS OPTIMIZATION USING SPECTROPHOTOMETERS

11

Page 12: PROCESS OPTIMIZATION USING SPECTROPHOTOMETERS

12

HMA Data vs Standard Method 5210B

Installation Locations 7

Number of LiquID Stations 11

Grab Samples (N) 100

Correlation (R2) 0.94

0

100

200

300

400

500

600

0 100 200 300 400 500 600

BO

D (

mg

/l)

– Z

APS H

MA

BOD (mg/l) – standard method 5210B

ZAPS Technologies, Inc.

Standard Lab Tests vs Spectrophotometry Correlation = 94%

Page 13: PROCESS OPTIMIZATION USING SPECTROPHOTOMETERS

13

Other Parameters

• ZAPS can monitor dozens of parameters in real time, very accurately

• For a complete list of parameters and accuracies and detection ranges, please call us or visit our website

• www. ZAPSTechnologies.com

Page 14: PROCESS OPTIMIZATION USING SPECTROPHOTOMETERS

14

Page 15: PROCESS OPTIMIZATION USING SPECTROPHOTOMETERS

15

Page 16: PROCESS OPTIMIZATION USING SPECTROPHOTOMETERS

16

Technique

Report Type

# of Days

# of Real-time Readings

Average Value (mg/L)

ZAPS LiquID

Daily average

1081 (99.5%)

677,244

215 mg/L

ZAPS Technologies, Inc.

Page 17: PROCESS OPTIMIZATION USING SPECTROPHOTOMETERS

17

Technique

Report Type

# of Days

# of Real-time Readings

Average Value (mg/L)

ZAPS LiquID

Daily average

181 (100%)

106,790

157

Municipal Lab

Daily Composite

78 (43%)

N/A

145

ZAPS Technologies, Inc.

R2 = 0.7

Page 18: PROCESS OPTIMIZATION USING SPECTROPHOTOMETERS

18

ZAPS Technologies, Inc.

Technique

Report Type

# of Days

# of Real-time Readings

Average Value (mg/L)

ZAPS LiquID

Real-time

7 (100%)

4,687

198

Municipal Lab

Daily Composite

3 (43%)

N/A

189

© ZAPS Technologies, Inc. ZAPS Technologies, Inc.

Page 19: PROCESS OPTIMIZATION USING SPECTROPHOTOMETERS

19

Technique

Report Type

# of Days

# of Real-time Readings

Average Value (mg/L)

ZAPS LiquID

Real-time

28 (100%)

18,116

212

Municipal Lab

Daily Composite

12 (43%)

N/A

213

ZAPS Technologies, Inc.

Page 20: PROCESS OPTIMIZATION USING SPECTROPHOTOMETERS

20

4,700 cBOD readings per series.

Raw Influent – Primary Effluent ––Final Effluent

ZAPS Technologies, Inc.

Page 21: PROCESS OPTIMIZATION USING SPECTROPHOTOMETERS

21

Raw Influent –Final Effluent

ZAPS Technologies, Inc.

4,700 cBOD readings per series.

Page 22: PROCESS OPTIMIZATION USING SPECTROPHOTOMETERS

22

0

100

200

300

400

500

600

12:00 AM 4:40 AM 9:20 AM 2:00 PM 6:40 PM 11:20 PM

Average

cB

OD

(m

g/L

)

213,642 cBOD readings

Diurnal Cycle – one year of data

ZAPS Technologies, Inc.

Calculate an average every minute of the day From 365 days of data

Page 23: PROCESS OPTIMIZATION USING SPECTROPHOTOMETERS

23

0

100

200

300

400

500

600

12:00 AM 4:40 AM 9:20 AM 2:00 PM 6:40 PM 11:20 PM

90th Percentile

75th Percentile

Average

25th Percentile

10th Percentile

cB

OD

(m

g/L

)

213,642 cBOD readings

Diurnal Cycle – one year of data

ZAPS Technologies, Inc.

Look at the variance from those averages

Page 24: PROCESS OPTIMIZATION USING SPECTROPHOTOMETERS

24

0

100

200

300

400

500

600

12:00 AM 4:40 AM 9:20 AM 2:00 PM 6:40 PM 11:20 PM

90th Percentile

75th Percentile

Average

25th Percentile

10th Percentile

Minimum Value

Maximum Value

cB

OD

(m

g/L

)

213,642 cBOD readings

Diurnal Cycle – one year of data

ZAPS Technologies, Inc.

We manage our plants based on conservative assumptions for maximum, minimum, and average loads

Page 25: PROCESS OPTIMIZATION USING SPECTROPHOTOMETERS

25

0

100

200

300

400

500

600

12:00 AM 4:40 AM 9:20 AM 2:00 PM 6:40 PM 11:20 PM

Maximum Value

90th Percentile

75th Percentile

Average

25th Percentile

10th Percentile

Minimum Value

cB

OD

(m

g/L

)

106,525 cBOD readings

Summer Season – Diurnal Cycle – one year of data

ZAPS Technologies, Inc.

Page 26: PROCESS OPTIMIZATION USING SPECTROPHOTOMETERS

26

0

100

200

300

400

500

600

12:00 AM 4:40 AM 9:20 AM 2:00 PM 6:40 PM 11:20 PM

Maximum Values

90th Percentile

75th Percentile

Average

25th Percentile

10th Percentile

Minimum Value

cB

OD

(m

g/L

)

107,117 cBOD readings

Winter Season – Diurnal Cycle – one year of data

ZAPS Technologies, Inc.

Page 27: PROCESS OPTIMIZATION USING SPECTROPHOTOMETERS

Waste

wate

r Secondary

Eff

luent

Waste

wate

r Fin

al E

ffluent

E. Coli (MPN/100ml) [5 point mean]

• Customer documented savings in chlor/dechlor and UV • Typically 50% of chemical and energy costs • Technology differentiates activated from deactivated Ecoli

27

Page 28: PROCESS OPTIMIZATION USING SPECTROPHOTOMETERS

• Back off disinfection until you start to see some activated Ecoli come through

• Machine sees activated Ecoli vs deactivated

• Customer wrote this article

• Using machines for four applications

• Monitoring final effluent helps see the effect of other changes to process

28

Page 29: PROCESS OPTIMIZATION USING SPECTROPHOTOMETERS

29

Page 30: PROCESS OPTIMIZATION USING SPECTROPHOTOMETERS

30

Page 31: PROCESS OPTIMIZATION USING SPECTROPHOTOMETERS

31

Page 32: PROCESS OPTIMIZATION USING SPECTROPHOTOMETERS

11.20C rain event Low pH

32

Page 33: PROCESS OPTIMIZATION USING SPECTROPHOTOMETERS

33

BETTER UNDERSTANDING LOADS

Page 34: PROCESS OPTIMIZATION USING SPECTROPHOTOMETERS

34

Automated Processes Total Per Day

Days 7

Automated Cleaning Cycles 219 31

Automated Calibration Checks (plotted) 47 7

cBOD Parameter Readings (plotted) 4,529 647

Manual Optics Cleans 1

LiquID cBOD – ‘Clean’ Parameter – Automated Calibrations

ZAPS Technologies, Inc.

Self Cleaning and Self Calibrating Online maintenance indicators

Page 35: PROCESS OPTIMIZATION USING SPECTROPHOTOMETERS

35

WUI screenshot

ZAPS Technologies, Inc.

USER INTERFACE

Page 36: PROCESS OPTIMIZATION USING SPECTROPHOTOMETERS

36

SPECTROPHOTOMETERS ENABLE:

• High definition, Real time • Direct measurement • Reproducible results • Enhanced reporting • Superior technology • Moving very fast

Page 37: PROCESS OPTIMIZATION USING SPECTROPHOTOMETERS

37

Presented by:

www.zapstechnologies.com

The value of data is determined by:

• how timely it is

• how much analysis was done on it

[email protected] 617-448-0440