The Bolt Stops Here!
Makes Doing Business Easy
That’s why when you call KENICK, you get aperson, not a voice mail system. And if wecan’t answer your question, we figure out whocan, and get back to you...quickly! (We know itmight seem unusual, but we actually like talk-ing to our customers.)
KENICK wants to help you operate and growyour business. That’s why we offer Power Qual-ity 101 training classes to all of our utilities aswell as free technical support. Not only for theproducts that we sell, but also for any powersystem distribution related questions. Our techsupport is available all the time, even afterhours and on week-ends.
Our owners and managers are all engineers,with more than 50 years of combined experi-ence. They love a challenge. If you have aproblem that you can’t figure out, call us andask - chances are, we have heard it before!
KENICK supports Made-In-The-USA products asoften as possible. Our SS320A Low Profile MeterBase Arrester is manufactured in St Petersburg,FL. Furthermore, we will not sell a productthat we do not believe in and have not testedourselves.
We operate our own 200,000 Amp testing labwhere we rigorously examine the capabilities ofall of our products. If you want to learn moreabout surge products, come visit our lab.
KENICK currently assists over 115 InvestorOwned Utiliites, Cooperatives, and Municipalswith their surge protection, training and tech-nical support needs. Being efficient and effec-tive in today’s market is crucial to the long-term health of any operation.
We enjoy helping you streamline and grow yourprogram. Let us make it easy!
At KENICK, we believe in selling superior products and maintainingexcellent customer relationships.
Tested Tough
As an independent company that does not rep-resent any single manufacturer, KENICK suppliesonly products that meet our stringent perfor-mance and safety standards. In order to fullyexamine the protection capabilities of all of theproducts that we sell, KENICK has its own200,000 Amp testing lab on-site at our head-quarters in St Petersburg so that we wouldn’thave to take anyone else’s word for it.
We regularly examine the protection capabili-ties of all of our products. If you have a prod-uct that is “under consideration”, send it to usand we will tell you how it measures up. Evenbetter, bring it with you and see our lab inaction!
At KENICK,We Make Sure it Works!
KENICK operates our own 200,000 Amp testing lab on-site.
Smarter ProgramManagement Support
KENICK has been assisting utility companiesmanage and grow their non-electric revenueprograms since 1989. We offer a wide range ofrevenue generating solutions including:
-meter-based, hard-wired and plug-insurge suppression options
-turn-key surge program management-a direct-to-customer sales channel
through SpikeStop.com-wiring protection programs-expanded warranty coverage programs.
1. Technical Expertise2. Experienced Program Managers3. Superior Service & Support
KENICK also offers the type of customer supportthat you just can’t find anymore. Our phonesare answered by real people. Our freetechnical support is available anytime, even onnights and weekends. We gladly conduct sitereviews for difficult or unusual cases. PowerQuality 101 training classes are available to allof our customers. Our team has the knowledge,experience and attitude to help, no matterwhat kind of opportunity is presented!
Our Goal is to be a Resource,Not Just a Supplier
Kenick offers three things that set us apart...
2013 Utility Product Catalog Copyright © KENICK, Inc.
www.kenick.com800-362-9997
SECTIONS
1. Meter Arresters
2. Hard-Wired Arresters
3. Plug-in Surge Suppressors
4. Data/Communication/Video Suppressors
5. Desktop/Stand-by UPS Battery Back-ups
6. On-Line UPS Systems
Don’t See What You Are Looking For?KENICK supplies over 500 different surge protection & powerquality products, but only the most popular make the catalog.
If you don’t see what you need, just give us a call at
800-362-9997.
2013 Utility Product Catalog Copyright © KENICK, Inc.
www.kenick.com800-362-9997
Features:• Thin low profile meterarrester• Use in 200Amp and 320Amp
meterenclosures• Low clamping voltage at high surge
currents• Thermally fused• Easy to install two part ground wire• UL1449 3rd Edition Listed TYPE 1
SpaceSaver SS320A Meter Arrester
DESCRIPTIONThe SS320A meter base arrester isyour first line of defense against powersurges. It has a low profile design andcan be installed on up to Class 320(320 amp) residential and commercialmeter enclosures.
The SS320A protects electrical circuitsand larger electromechanical applianc-es. It contains high energy surge pro-tection elements that can handle surgesin excess of 45,000 amps per electricalline.
The SS320A is designed for safety witha thermal disconnect on each phaseconductor and an internal shield forsafe installation A “dual-redundant” LEDlight source verifies that the SS320Asurge protection circuit is functional.
SPECIFICATIONS• Very low profile: 1.2"• UL listed for up to 320 Amp services• 240 Volt Single Phase• Simple ON/OFF Indicator• Plastic safety guide shield• Two part ground connection• Response Time……………….< 1 nanosecond• Maximum Surge Current… 45,000 amps/phase• Maximum Energy Absorption… 4,000 joules
(2,000 joules/phase)• Initial Clamping Voltage……… 240
volts/nominal• Clamp Voltage @ 3000 A….. 700 volts/nominal• Maximum Allowable Voltage (L-N)…. 180volts
rms/ 50-60 hz• Special Thermal Disconnects/Fuses• Indication…………..Dual Redundant LED• Maximum Fault Interrupt Rating.. 200,000
Amps
MODEL NUMBERSApplication Order Model200 to 320 Amp Meter Enclosures SS320A200 to 320 Amp Meter Enc. w/5th Jaw SS320A-5JOptional 36 inch ground lead extension: SS320-36GQuick-Drill™ ground connector option add “-QD”
2013 Utility Product Catalog Copyright © KENICK, Inc.
www.kenick.com800-362-9997
Features:• Very low clamping voltage• Easy, plug-in installation• Safety fused• Withstands direct lightning
energy• Instant response to surges, no
impact on normal power• Reliable, long-life design
K400ISL Meter Arrester
DESCRIPTIONThe KENICK meter surge suppressor,model K400ISL, is the first stage inwhole house protection. And its tough,with a very low clamping voltage. Evenat extreme lightning currents.
The K400ISL is ideal for the first stage ofprotection for the home office or smallbusiness.
APPLICATIONStandard electric utility safety prac-tices, policies and procedures mustbe followed for K400ISL installation.This product must be installed byelectric utility personnel only, or autility approved, trained electricalcontractor.
Sensitive electronics such as com-puters and entertainment systemsmust be protected by point-of-useplug-in protectors.
SPECIFICATIONSResponse time.......................... less than 1 nanosecondRated surge current................................... 55,000 ampsRated surge energy..................................... 4,000 joulesClamp voltage................................................... 240 voltsSafety fuse................................................................ YesTen year warranty..................................................... YesEach unit factory tested............................................ Yes
2013 Utility Product Catalog Copyright © KENICK, Inc.
www.kenick.com800-362-9997
Features:• 40 kA 8/20 µs per phase• Type 1 SPD, UL® 1449Edition 3 Listed• All standard service voltages• Compact NEMA®-4Xenclosure can be installedoutdoors• LED status indication
MPAF Series
SPECIFICATIONS
ORDERING INFORMATION
INSTALLATION INFORMATION
DESCRIPTION
The MPAF Series of Surge Protection Devices provide utility grade protection against damaging tran-sients and surge events. These products are UL and cUL® listed to 1449 Edition 3 as Type 1 devices.They have a 200 kIAC interrupt rating so they can be installed on services capable of up to 200 kIACfault current. This allows them to be installed on the line or load side of the service panel inaccordance with the NEC® 2011 without the requirement for additional circuit breakers or fuses.
Primary applications are service entrance, branch and OEM panels UL 96A lightning protectioninstallations and light pole applications. The housing is constructed of UV-stabilized thermoplasticand designed to meet the UL 50 Type 4 rating, making it ideal for both indoor and outdoor NEMA 4Xapplications.
Response Time ............................................................................... <1 nanosecondMaximum Surge Current ........................................................... 40,000 Amps/phaseMax. Energy Absorption (2ms) ............................................... 360 Joules per phaseMax Interrupt Current ................................................................................ 200 kAICEnclosure ................................................................................................. NEMA 4XMounting ......................................................... 3/4" standard for 1.14" dis. knockoutNominal Discharge Current ................................................... 20 kA 8 x 20 per modeFailure Mode ................................................................... Failsafe (short) and FusedFailure Indication ............................................................................... LED IndicatorsSurge Life @ 10,000A .................................................................... >50 OccurancesSize .................................................................................... 2.44" x 3.43" x 3.90"
The MPAF SERIES SPDs are supplied with 18” of 12AWG leads for a direct hardwired connection.With the POWER OFF, connect the neutral conductor of the SPD to the neutral lug in the panel.Connect each black lead (phasing is not critical to the operation). Wire lengths should be mini-mized to improve performance. There is no minimum wire length requirement. See installationinstructions included in box for details.
Models:
MPAF120-1P ..................................................................single pole 120V to groundMPAF240-1P ................................................................. single pole 240V to groundMPAF120/240-1P ....................................................two pole 240 V phase to phaseMPAF208-3P ........................................................................three phase 120/208 VMPAF480-3P ........................................................................three phase 277/480V
2013 Utility Product Catalog Copyright © KENICK, Inc.
www.kenick.com800-362-9997
Features:• 240V single phase Type 1SPD for main & branch panels• <1 ns Response Time• 40,000 Amps per phase• Failsafe and fused• Operational status indicators• UL 1449 3rd Edition Listed
SS400HW Single Phase
SPECIFICATIONS
ORDERING INFORMATION
The SS400HW is a rugged highly reliable hardwire surge protector for residential or commercialstandard 120/240V single (split) phase applications.
The SS400HW features totally solid state construction for long term reliability and quick response tosurges. Two advanced, commercial grade metal oxide varistors (MOV) are the primary protectiveelements. These MOV's are each capable of handling 40,000 Amps of surge current.The protection components are designed to fail shorted and are fused. After a typical surge, the sup-pressor automatically recovers and is ready for the next surge. In a rare event of MOV failure, thefuse opens and the indicator LED turns off.
Response Time ................................................................................ <1 nanosecondMaximum Surge Current ........................................................... 40,000 Amps/phaseInitial Clamping Voltage ............................................................... 240 Volts NominalClamp Voltage @ 3000 ............................................................... 700 Volts NominalMax. Allowable Voltage (L-N) .................................................... 180 Vrms 50-60 HzFailure Mode .............................................................................. Failsafe and FusedFailure Indication ................................................................................ LED IndicatorSurge Life @ 10,000A .................................................................... >50 OccurancesSize ................................................................................................ 3.50" x 3.25" x 3"
Model SS400HW
INSTALLATION INFORMATIONThe SS400HW is listed as a Type 1 SPD to UL1449 3rdedition. To install, follow Installation Instructions includedin the packaging. The SS400HW is rated for installationon electric services before the main disconnect or afterthe main disconnect. It is internally fused and does notneed external fuses or breakers. It must be installed perNational Electric Code Section 285.
The SS400HW can be installed on services rated up to200,000 Amps fault current.
ØA
120VMax
120VMax
G N D N A B
BLK
BLK
WHITE
Phases: Black
Neutral: White
Ground: Green
DESCRIPTION
2013 Utility Product Catalog Copyright © KENICK, Inc.
www.kenick.com800-362-9997
Features:•Single orThree Phase•Compact for installation onvirtuallyanypanel
• Intelligent: indicators foreachprotection mode
•High surge capacity• InternallyFused with 200 kAICinterrupt rating
EXT50C Series
DESCRIPTION
ORDERING INFOMATIONAvailable voltages:EXT50C-120/240 1Ph,EXT50C-120/208Y 3Ph,EXT50C-120/240D 3 Ph,EXT50C-277/480 3 PHEXT50C-UPS 3PH Universal Voltage
The EXT series is listed as a TVSS to UL1449 Edition 3. The EXT series is rated as a TYPE 1 SPDdevice for installation on electric services upstream or downstream of the main. It must be installed perNational Electric Code.
The EXT can be installed on services rated for up to 200,000 Amps fault current without external fusing.For services rated more than 200,000 Amps, contact KENICK.
INSTALLATION INFORMATION
The EXT50C Series SPD is a compact, state of the art surge protection system. Its compact sizesaves valuable electrical room space. Plus, it can be installed in most retrofit situations. Availablewith a surge rating of 50kA, the EXT50C is listed to UL 1449 Edition 3. The EXT50C is listed as aTYPE 1 device which means you don’t have to worry about where to install it can be installedupstream or downstream of the service main disconnect.
Using special hybrid technology, the EXT series has lower let through voltages at high surge currentsthan similar hardwire devices. In addition its technology prevents premature failure under unusualvoltage excursions.
Exclusive multipath protection means that redundant surge elements continue to provide protectioneven should an internal surge element fail. The EXT series includes intelligent indicators for each pro-tection mode. You can confirm total protection with a quick inspection of the LED indicators.
ØA ØC
277VMax
277VMax 277V
Max
G N D N Ø A Ø B Ø C
BLK
BLK
BLK
WHITE
GREEN
ØB
Phases: Black
Neutral: White
Ground: Green
2013 Utility Product Catalog Copyright © KENICK, Inc.
www.kenick.com800-362-9997
Features:•Hot Swappable Field ReplaceableModules•Single orThree Phase•Compact- installson anypanel• Intelligent: indicators foreachprotection mode
•High surge capacity• Internally fused with 200kAICrating
EXT100M Series
DESCRIPTION
ORDERING INFOMATIONAvailable in the following Models:EXT100M-120/240 1Ph,EXT100M-120/208Y 3Ph,EXT100M-120/240D 3 Ph,EXT100M-277/480 3 PH
Surge ratings:EXT100M: 100,000 Amps Peak Surge Rating/Phase
The EXT series is listed as a TVSS to UL1449 edition 2.5 and Edition 3. The EXT series is rated as aTYPE 1 device for installation on electric services upstream or downstream of the main. It must beinstalled per National Electric Code.
The EXT can be installed on services rated up to 200,000 Amps fault current without external fusing.For services rated more than 200,000 Amps, contact KENICK.
INSTALLATION INFOMATION
The EXT100M Series is a compact, state of the art high energy surge protection system. Its compactsize saves valuable electrical room space. Plus, it can be installed in most retrofit situations.
Available with a surge rating of 100kA, the EXT100M is listed to UL 1449 Edition 2.5 and UL 1449Edition 3. The EXT100M is listed as a TYPE 1 device which means you don’t have to worry aboutwhere to install it- it can be installed upstream or downstream of the service maindisconnect. The EXT100M series is Modular and “Hot Swappable”- the surgemodules can be field replaced without removing the suppressor!
Using special technology, the EXT series has lower let through voltages at highsurge currents than standard similar devices. In addition its technology preventspremature failure under unusual voltage conditions. Exclusive multipath protectionmeans that redundant surge elements continue to provide protection even should aninternal surge element fail.
The EXT series includes intelligent indicators for each protection mode. You canconfirm total protection with a quick inspection. In addition the 100kA EXT100Mseries units include dry contacts for optional remote monitoring.
ØA ØC
277VMax
277VMax 277V
Max
G N D N Ø A Ø B Ø C
BLK
BLK
BLK
WHITE
GREEN
ØB
Phases: Black
Neutral: White
Ground: Green
2013 Utility Product Catalog Copyright © KENICK, Inc.
www.kenick.com800-362-9997
Features:• Designed to be installed with mainelectrical surge suppression• Automatic recovery• Fast response time• High EnergyVideo suppressor•Dual telephone line protectorwithreplaceable modules•Meetsall applicable standards
DESCRIPTION SPECIFICATIONS
INSTALLATION
Service Entrance Protection
The Service Entrance Protection packageconsists of a high quality video suppressorplus a twin telephone suppressor. This pack-age is designed for utility surge protectionp rograms where an ou ts ide “se rv iceentrance” surge suppressor is installed. Thepackage features easy installation by quali-fied personnel.
The 212FF Video Data Suppressor protectselectronic cable equipment from lightningand power induced surges on coaxial dropcables. It is specifically designed for today’sBroadband Hybrid Fiber Coax and Fiber-To-The-Curb distribution networks. A conve-nient ground connection is located on themounting block.
The Tel Twin suppressor is weather resistantand provides superior lightning and surgeprotection for up to two Telephone, DSL,ISDN or T1 lines. Protection is provided bydual suppression modules that feature self-sealing screw terminals. The suppressionmodules feature field replaceable cartridges.
The Twin Tel suppressor features an impactand weather resistant enclosure. Break-awayholes are provided on the rear of the enclo-sure for mounting. A ground terminal is pro-vided in the lightning protector enclosure pro-viding superior grounding.
212FF Video1. Mount 212FF Video near main service sup-pression.2. Connect Coax IN and Out3. Connect ground to same ground as main ser-vice suppression.
Twin Tel1. Mount Twin Tel near main service suppres-sion using break away holes inside enclosure.2. Insert inbound tel wires into input connectorand tighten screws.3. Insert outbound tel wires into output connec-tor and tighten screws.4. Connect ground to same ground as mainservice suppression
212FF Video
Listed to UL 497 & CSA CertifiedFrequency Range DC - 1.5 GHzFrequency Range DC - 1.5 GHzDesigned for Broadband Network Applications
Twin Tel
Replaceable surge modulesClamping Voltage 230 VDimensions 2.52 x 2.39 x 4 (inches)Protects up to two phone linesLocking hinged cover & self sealing terminalsEasy installation, no wire stripping required
212FF Video Suppressor
Tel Twin Suppressor
2013 Utility Product Catalog Copyright © KENICK, Inc.
www.kenick.com800-362-9997
Features:• 120 Volt 15Amp Hardwired• Automatic recovery• Fast response time• Power line tracking• 3 Stage Hybrid Design• UL1449 Recognized
DESCRIPTION SPECIFICATIONS
INSTALLATION
HSP-121-BT-1RU
DIMENSIONS
3.987 "5.25"
GRD
AC
NEUT
GRDLIGHT ON - NORMAL
120VAC 15AMPSMAX
LIGHT OFF - REQUIRES
LINE
EQUIP
AC
2.95"1.17"
HOLES 3/16"DIA.
1.17"
4.86"
NEUT
SERVICE
The HSP121BT-1RU is an advanced 3 stagehybrid, solid state power line protector. Featuressuch as noise filtering, common mode and nor-mal mode suppression, nanosecond reactiontime, power line tracking, and compressionscrew terminations, make the HSP121BT-1RUan excellent choice in commercial and industrialapplications.
The HSP121BT-1RU offers a replaceable fusedes igned to remove the load (pro tectedequipment) from the line if the unit is either over-loaded or the internal protection fails. This fea-ture prevents surges from entering equipmentthrough a failed protector, not noticed by the user.Unlike models with only an indicator, which maytake weeks to notice, the HSP121BT-1RUdemands immediate attention upon the unlikelyoccurrence of internal failure.
1. Mount HSP121BT-1RU in a UL Listed housing.2. Make sure wiring from power sources properly connects to line side of HSP.
Wiring from protected equipment must properly connect to EQUIP side of HSP.3. Indication of internal failure:
a. Indicator will extinguishb. Fuse blown will disconnect load from power source.
WARNING: For continued protection against risk of fire, replace only with same type rating of fuse.
4. Connect only to 120 VAC, 15 Amp max., single phase, three wire circuit.
Clamping Cat.: ............... 330V L-N, 400V L-GANSI/IEEE C62.41 1991-Cat. Cl/B3 Peak Clamp Voltage...........315V L-N, 350V L-GMax Single Pulse....................................... 10kAResponse Time ....................... <5 nanosecondsOperational Temperature............ 20°C to +85°CFailure Indication......................................... LEDOperational Voltage.................... 120VAC, 60HzOperational Current................ 15 AMPS ServiceDimensions........................ 2.87" x 5.25" x 1.75"
2013 Utility Product Catalog Copyright © KENICK, Inc.
www.kenick.com800-362-9997
Features:• 120 or240 Volt 20Amp SeriesHardwired• Automatic recovery• Fast response time• Power line tracking• Multi-Stage Hybrid Design• Easy Installation
DESCRIPTION
SPECIFICATIONS
INSTALLATION
VSS20-PM
The VSS20-PM is an advanced multi-stagehybrid, solid state power line protector. Featuressuch as common mode and normal mode sup-pression, nanosecond reaction time, power linetracking, and simple wire terminations, make theVSS20-PM an excellent choice in commercialand industrial applications.
The VSS20PM takes up NO internal panel room;it’s designed to be mounted externally through ahalf inch knockout.
The VSS20-PM utilizes a Patented* X-Coil™surge balancing coil. This insures best clampingperformance of all internal surge elements.
The VSS20-PM contains internal fuses designedto remove the load (protected equipment) fromthe line if the unit is subject to long termovervoltgaes or the internal protection fails. Thisfeature prevents surges from entering equipmentthrough a failed protector, not noticed by the user.The VSS20-PM is universal: it can be used onany single phase circuit of either 120Vac or
1. Mount VSS20-PM in a 1/2" knockout in the panel housing.2. Make sure wiring from power sources properly connects to line side of VSS20-PM.
Wiring from protected equipment must properly connect to EQUIP side of VSS20-PM.3. Indication of internal failure:
a. Indicator will extinguishb. Fuse blown will disconnect load from power source.
4. Connect only to 120 or 240 VAC, 20 Amp max., single phase, three wire circuit.
SPD Type 2Clamping Cat.: ............... 400V L-N, 400V L-GMax Single Pulse....................................... 10kAResponse Time ....................... <5 nanosecondsOperational Temperature............ 20°C to +85°CFailure Indication......................................... LEDOperational Voltage.......... 120 or 240VAC, 60HzOperational Current................ 20 AMPS ServiceDimensions........................ 2.87" x 5.25" x 1.75"
240Vac. It is designed to carry 20 Amp max cur-rent so it fits any commercial wiring system.
The VSS20-PM is a series surge device so it hasseparate input wires and output wires. The outputwires are clearly marked and connect to the elec-tronics that are to be protected. Simple wire splic-es or wire nuts are acceptable connections to theVSS20-PM
2013 Utility Product Catalog Copyright © KENICK, Inc.
www.kenick.com800-362-9997
Features:• 8 protected power receptacles• Twin video suppressors• Telephone suppressor• Includes video/phone
cables• Nanosecond Speed• Meets IEEE 587 CAT. B• Multi-Function Indicators• UL1449 3rd Edition Listed
TELEPHONE Protection
DESCRIPTION VIDEO Protection
MPM8-AV Multimedia Power Strip
The MPM8-AV Multimedia Power Stripsuppressor has eight receptacles topower your sensitive electronics. Its highenergy circuitry absorbs and reroutessurge energy to ground or, in the event ofcatastrophic surge, completely discon-nects power.The MPM8-AV receptacles are spaced tofit power blocks (transformers). Diagnos-tic lights indicate proper grounding andoutlet wiring.
MPM8-AV is cable and HDready wi th twin coaxia lmodules to protect cable TV,satellite and cable modems.
MPM8-AV is also telephoneready with phone line protec-tion including PTC auto-resetmodules to protect pay-per-view,fax, telephone lines andmodems.
PERFORMANCE
The MPM8-AV multi stage protection han-dles six times the surge energy while stillprotecting your sensitive electronics. Letthrough voltage is the lowest on the mar-ket at a full 3,000 amps surge current.
WARRANTY INFORMATION
MPM8-AV is a Panamax product sup-plied by PEMCO. MPM8-AV is warrant-ed by PEMCO to its standard warranty.
2013 Utility Product Catalog Copyright © KENICK, Inc.
www.kenick.com800-362-9997
Features:• 6 rotating power receptacles• Two video suppressors• Two line phone protection• RJ-45 Networkprotection• Nanosecond Speed• Includesvideo and phone
adapters• Multi-Function Indicator
PHONE Protection
US1206 is also telephoneready with phone line protec-tion including twin PTC auto-reset modules to protect pay-per-view,fax, te lephone l ines andmodems.
DESCRIPTION
VIDEO ProtectionUS1206 is cable readywith twin coaxial suppres-sion modules protect cableTV, satel l i te and cablemodems.
US1206 Universal Suppressor
US1206 universal suppressor has sixreceptacles to power your sensitive elec-tronics. Its circuitry absorbs and reroutessurge energy to ground or, in the event ofcatastrophic surge, completely discon-nects power.US1206 receptacles rotate so that cordsare out of the way for installations behinddesks and other furniture. The US1206includes intelligent indicators to diagnoseproper grounding and outlet wiring.
SIX TIMES STRONGER
The US1206 multi-stage protection han-dles six times the surge energy while stillprotecting your sensitive electronics. Letthrough voltage is the best on the mar-ket even at a full 3,000 amps surge cur-rent.
NETWORK ProtectionThe US1206 includes net-work protection for comput-er networks. Standard RJ-45 cables have all 8 wiresprotected.
SWIVELRECEPTACLESUses less spacefor very compactinstallations
2013 Utility Product Catalog Copyright © KENICK, Inc.
www.kenick.com800-362-9997
Features:• 8 power receptaclesspaced for
transformers• Includes voltage drop out
relay• Includes two video suppressors• Includesphone suppressor• Nanosecond Speed• Meets IEEE 587 CAT. B• UL1449 Listed
TELEPHONE ProtectionDESCRIPTION
VIDEO Protection
XM8-AV Multimedia Power Strip
The XM8-AV Multimedia Power Strip 8receptacle suppressor absorbs andreroutes surge energy or, in the event ofcatastrophic surge, completely discon-nects power. It also disconnects powerif voltage is outside the normal operatingrangeThe XM8-AV has receptacles spaced tofit power blocks and diagnostic lightsthat indicates proper grounding and out-let wiring. XM8-AV is cable ready with
triple coaxial modules toprotect cable TV, satelliteand cable modems.
XM8-AV is also telephoneready with a double outp h o n e l i n e p ro t e c t i o nincluding PTC auto-resetmodules to protect pay-per-view,fax, telephone linesand modems.
PERFORMANCE
The XM8-AV multi stage protection han-dles six times the surge energy while stillprotecting your sensitive electronics. Letthrough voltage is the lowest on the mar-ket even at a full 3,000 amps surge cur-rent.
WARRANTY INFORMATIONXM8-AV is a Panamax product suppliedby PEMCO. XM8-AV is warranted byPEMCO to its standard warranty.
During brief over-voltage or under-voltage events, the XM8-AV protectselectronics by switching itself off.This protects appliances during openneutral conditions.
VOLTAGE DROP RELAY
2013 Utility Product Catalog Copyright © KENICK, Inc.
www.kenick.com800-362-9997
Features:• 4 power receptaclesspaced for
transformers• Includesvoltage drop out relay• IncludesLANand/orphone
protection & adapters• Multi-Function Indicators• UL1449 Listed
LAN & TELEPHONE ProtectionDESCRIPTION
XM4T-EX Multimedia Power Strip
The XM4T-EX Multimedia Power Stripcombines surge protection, noise filtra-tion and optional LAN or telephone lineprotection into one compact unit. Its cir-cuitry absorbs and reroutes surge energy,or in the event of a catastrophic surge,completely disconnects power. It alsodisconnects power if voltage is outsidethe normal rangeThe XM4T-EX has receptacles spaced tofit power blocks and diagnostic lights thatindicates proper grounding and outletwiring.
XM4T-EX combines bothLAN and telephone line pro-tection into 1 set of jacks.Plugs include PTC auto-reset modules and can beused for various types ofprotection for Pay-Per-View,Fax, Telephone lines,DSL modems or LAN.
PERFORMANCE
The XM4T-EX multi stage protectionhandles six times the surge energy whilestill protecting your sensitive electronics.Let through voltage is the lowest on themarket even at a full 3,000 amps surgecurrent.
WARRANTY INFORMATIONXM4T-EX is a Panamax product sup-plied by PEMCO. XM4T-EX is warrant-ed by PEMCO to its standard warranty.
During brief over-voltage or under-voltage events, the XM4T-EX protectselectronics by switching itself off.This protects appliances during openneutral conditions.
VOLTAGE DROP RELAY
2013 Utility Product Catalog Copyright © KENICK, Inc.
www.kenick.com800-362-9997
Features:• Multi-Stage for lowest let
through voltage• Patented Surge Coil• Nanosecond Speed• ExternalGround Bar• Rugged weatherproof housing• Cord optionsavailable (see
modelnumbers)
DESCRIPTION
VSS20-G Multi Stage Suppressor
The VSS20G suppressor is a specialmult-stage suppressor designed to beused in extreme locations such as outdoorpower cabinets and gate controller cabi-nets. Its multi-stage design provides theabsolute lowest clamping voltage com-pared to single stage designs.The VSS20G utilizes Patented X-Coildesign (US Pat #7,085,115) which allowsnormal current flow without overheatinglike a normal surge coil. This allows acompact design along with ability to han-dle up to 20 amps of current.Its circuitry absorbs and reroutes surgeenergy to ground or, in the event of cata-strophic surge, completely disconnectspower.The surge circuitry uses the latest TMOVsurge elements which incorporate internalthermal disconnects for safety.The VSS20G includes an external groundbar that can be used to add suppressionmodules for data, vehicle loop dectors,weighing scales, telephone, gate accesscards, etc. This provides a single pointground for all surge devices.
SPECIFICATIONSLet through voltage at 6 kV and 3,000Amp peak- 500 VoltsThermal disconnects for fire safetyPatent Pending X-Coil design ( US#7,085,115)Dual Voltage- either 120 V or 240 Voperation20 amp ratedSpecial Internal Current Limiting Fuses-stops current due to high voltage linedropRated for 200,000 amp fault currentSurge durable up to 40,000 amps peaksurge currentHeavy duty- for long reliable life in fieldconditionsSmall size- less than 1 1/4 ” tallCord connected for easy installation
MODEL NUMBERS
ex: VSS20G - 9 - 6 -18 - 6205-20, 6-20,5-15, etc.plugs
Output CordLength in inches
Input cord lengthin inches
9=90 deg male plug;S= straight male plug
20= 20 amp; 15= 15 amp
Special Note:Due to the use ofspecial series fus-ing, the VSS20design cannot belisted to UL1449.Internal compo-nents are all ULrecognized andlisted.
2013 Utility Product Catalog Copyright © KENICK, Inc.
www.kenick.com800-362-9997
Features:• 120 Volt General Use• Twin Receptacle• Simple Plug-In Installation• Intelligent indicator diagnoseswiring and grounding• Available with telephone pro-tection, video protection or both• Multi-stage protection
SPECIFICATIONSDESCRIPTION
ORDERING INFORMATION
120V single circuitUL Clamp Voltage (500) amps: < 330 voltsResponse time: less than 1 nanosecondPowerful 20mm MOV elementsOutput disconnect on failureThemal fused MOVs for fail safe disconnect
All models are 120 Volt single circuit.PMD2 Twin ReceptaclePMD2-CT Combo with telephone & video protectionPMD2-C Combo with video protectionPMD2-T Combo with Telephone protection
The PMD2 series wall mount suppressoris designed to protect 120 Volt electron-ics with up to 15 amps current carryingcapability. PMD2 has outlets on thes ides (90 degree angle f rom oneanother) to accommodate a variety ofplugs.
The PMD2 features multi-stage suppres-sion giving the benefits of lowest clamp-ing voltage even at very high surgeenergy. The PM2D provides cleanpower by filtering out noise common tohousehold power
In the event of a catastrophic surge suchas lightning, it completely disconnectsAC power to connected equipment.
The PMD2 series is UL listed to the lat-est 3rd edition 1449 standard.
PMD2 Wall Mount Series
PMD2-CT
PMD2-C
2013 Utility Product Catalog Copyright © KENICK, Inc.
www.kenick.com800-362-9997
Features:• 120 Volt General Use• Single Receptacle• Simple Plug-In Installation• Intelligent indicator diagnoseswiring and grounding• Available with telephone pro-tection• Available with video protection
SPECIFICATIONSDESCRIPTION
ORDERING INFORMATION
120V single circuitUL Clamp Voltage (500) amps: < 330 voltsResponse time: less than 1 nanosecondPowerful 20mm MOV elementsThemal fused MOVs for fail safe disconnect
All models are 120 Volt single circuit.
CSS-1 Single ReceptacleCSS-1T Single Receptacle Combo with telephone protectionCSS-1V Single Receptacle Combo with video protection
The CSS series compact suppressor isdesigned to protect 120 Volt electronicswith up to 15 amps current carryingcapability.
The CSS series is a single stage recep-tacle suppressor that plugs into a stan-dard wall outlet. It uses larger surgeelments but does not have mulit-stageprotection circuitry.
The CSS series is used to protect sim-ple electronics, microwaves, and garagedoor openers.
The CSS series is available with a tele-phone suppressor, with a video suppres-sor, and as a stand alone single outletsuppressor.
Compact CSS Series
CSS-1T
CSS-1V
2013 Utility Product Catalog Copyright © KENICK, Inc.
www.kenick.com800-362-9997
Features:• Automatic Recovery• Low Insertion Loss• Easily Installed• Shielded Case
SPECIFICATIONS
CATV-145A Cable TV Protection
75 Ohm Coax
The CATV-145A application is specifical-ly designed for lightning protection onCoax Cable TV Systems. The protectoris easily installed with standard type Fcoax connectors. A ground wire must beattached to the unit. The CATV-145Aoffers low loss even at frequenciesapproaching 500 Mhz. This is importantfor error-free data communication appli-cations.
Attenuation........................... 0.1db @ 500MhzResponse Time..................... 100ns @ 10kv/µsSpark-over Voltage.........50 volts @ 10kv/µs typ.Surge Handling (1time)............................ 5 kA(8x20µs)Connector............................... Type FDimensions....................... 4.5" x 1.5" x 1.25"Weight................................................... 4 oz.Matching Z...................................... 75 Ohms
APPLICATION
2013 Utility Product Catalog Copyright © KENICK, Inc.
www.kenick.com800-362-9997
Features:• Tip, Ring to Ground Protection• UtilizesMGB Grounding Rail• Over-Current Protection -PTC's• State-of-the-Art Silicon Technology• ULListed 497A• Replacesbridging clipson Ml-50Block• Test PointAccessible
HCO SERIES
MGB
89D STAND OFFM1 - 50BLOCK
TESTPOINTS
PROTECTED SIDE
UNPROTECTEDFIELD SIDEWIRING
INSTALLATION
ORDERING INFORMATION
HCO Series modules are fused solid state sec-ondary protectors for Key/PABX C.O. (CentralOffice) trunk pairs. The units are available in twodifferent circuit configurations. The HCO is con-structed with solid state silicon avalanchefoldback technology and fuses. The HCO fea-tures solid state silicon avalanche foldback tech-nology and polyswitch resettable fuses - PTC's.These protection modules are intended to beused in conjunction with proper primary protec-tors (UL 497). The circuitry is designed for pairswith ring voltage present, and incorporatesovercurrent protection required by UL 497A. Theprotective elements switch from the normal highimpedance state to a low impedance state upondetection of a surge, then switches back to highimpedance after the surge has passed.
The HCO and HCO fit onto a standard M1-50split block and replace the bridging clips. Inaddition these modules require the EDCO MGBground rail for each M1-50 Block used.
For digital or analog internal extension lines,order the HDE or HAE suppressor.
HCO-200:(Silicon Avalanche Foldback and Fuses)
HCO-200T:(Silicon Avalanche Foldback and Polyswitchresettable Fuses - (PTC's)
TTA-2:(Test Point Plug Available)
DC Breakover Voltage:T-R............................................................. 300-380VT-G............................................................. 300-380VR-G............................................................ 300-380V
Stand-Off Voltage (min)................................... ±240VLeakage Current (max. @ 60HZ)....................... 10µAHolding Current (min)....................................... 150maPeak On-State Voltage (It = 1A)............................. 3VResponse Time................................................... <1nsPeak Pulse Current (10 x l000µs):Applied between T-R, T-G, R-G.......................... 100AApplied simultaneously:
T-G and R-G..................................................... 200AOperating Temperature...................... -40°C to +70°CCapacitance (50 VDC Bias)............................ <100pfOver-Current Limiting ........................ Meets UL 497ADimensions (overall) LxWxH.......... 2.9" x 0.4" x 1.25"
SPECIFICATIONSDESCRIPTION
2013 Utility Product Catalog Copyright © KENICK, Inc.
www.kenick.com800-362-9997
Features:• <1 Nanosecond ResponseTime• Solid-State Silicon BreakoverTechnology• Low Capacitance• UL497AListed• Resettable fusesPTCs
Part Number Max Peak Nominal Max CurrentMaxClamp Typ Cap Max Continuous Nominal SeriesSignal Voltage Breakdown Voltage Ip 10X1000µsVoltage @ Ip (pf) Current Resistance
FAS-TEL-015TFAS-TEL-030TFAS-TEL-050TFAS-TEL-060TFAS-TEL-200T
FAS-31XT
8 Ohms8 Ohms8 Ohms8 Ohms8 Ohms8 Ohms
124714536
10 *10 *
21001180900750100100
* NOTE: Forward Voltage After Break over
12244352
220220
15305060
300300
150ma150ma150ma150ma150ma150ma
20385766
200A (T-G)+(R-G)200A (T-G)+(R-G)
FAS-TEL & FAS-31XT
SPECIFICATIONS
INSTALLATION
PH O N E
TE LC O
BL SL W T
RD GN
TO ALARM SYSTEM
HARDWIRE DIRECTLY FORNEW ALARM INSTALLATIONS
O R
USE PROVIDED 2' CORD WITH MALE RJ FORINSTALLATIONS WITH EXISTING 31X TELEPHONE JACK.
Building Approved ground
PROTECTEDSIDE
FAS-31XT
497A
UL
TE LC O
BL
SL
-W T
RD G N
PROTECTEDSIDE
UNPROTECTEDSIDE
HARDWIRE
O R
USE PROVIDED 6‘CORD WITH MALE RJ
TO PHONE OR COMPUTERS
RJ or HARDWIRE
Building Approvedground
FAS-TEL
Application: General UseTelephoneThe FAS-TEL and FAS-31XT are single pair telephone or data line protectors that implementadvanced two stage hybrid design. These units address over voltage transients with siliconbreakover devices, while sneak and fault currents are mitigated with new "PTC" technology whichconsist of solid state re-settable fuses.
FAS-31XT replaces the RJ31X jack with a protected version. Four screw terminals are provided towire the protector in the same manner as a standard RJ31X jack. The FAS-31XT can be used aloneor as an accessory to a plug in surge protector. Use a plug in protector that will provide a convenientgrounding point for the FAS-31XT / FAS-TEL ground wire.
2013 Utility Product Catalog Copyright © KENICK, Inc.
www.kenick.com800-362-9997
Features:• Lightning Protection forLow Volt-age• Data SignalLines• Three-Stage Protection• Sneak/Fault Current ProtectionResettable Fusing -PTC's• Low Capacitance Option ¤• Plug-in Module• UL497B Listed
stage 2 clampline-line & line-gnd
50 Volts 0 5 060 Volts 0 6 0
*200 Volts 2 0 0
low capacitancestage 2 clampline-line & line-gnd
stage 2 clampline-to-line only
PC642C-008LC & PCB1BPC642C-008LC & PCB1BPC642C-020 & PCB1BPC642C-030LC & PCB1BPC642C-030 & PCB1BPC642C-200 & PCB1BPC642C-060LC & PCB1B
¤
APPLICATIONRS485, RS422:RS423, Token Ring:RS232E-NET, 10BASET:4-20 ma
:Telephone (C.O. line):Telephone T1 Data:
PC642
PCB1B
8 Volts 0 0 815 Volts 0 1 520 Volts 0 2 030 Volts 0 3 036 Volts 0 3 643 Volts 0 4 3
VOLTAGE CLAMP
LC
X
D
PC642C
* Not UL Listed
no suffixclamps line-gnd
(see note: ¤ )
DX
SPECIFICATIONS
PC642 SERIES
ORDERING INFORMATION
TERMINAL ASSIGNMENTS
Ground Terminal 1 or 10 to Building Approved Ground
ProtectedPair 2Electronics SideProtectedPair 1
KEYING PIN
{ {
OddTerminals
EvenTerminals
10
5
1
9
2
{
1.0
{
PCB1B:
4
UnprotectedPair 2
Field SideUnprotected
Pair 1 3
6
87
The PC642 Series surge suppressor is a dual pair(four wire) module implementing three stage hybridtechnology. This module addresses over voltagetransients with gas tubes and silicon avalanchecomponents. In addition, sneak and fault currentsare mitigated with resettable fuses (PTC's).
The PC642 card edge module is designed to matewith the PCB1B female terminal connector.
Peak Surge Current (10 times):8 x 20µs ................................................ 10kA10 x 700µs ................................... 500A per line
Life Expectancy: 8 x 20µs (2000A)........... >100 occurrences 10 x 700µs (400A)
Response Time................................... <1 nanosecondVoltage Clamp ..... 8, 15, 20, 30, 36, 43, 50, 60 or 200Technology................................................ SAD HybridResistance (depends on mod.).. 4.7W to 15W per lineCapacitance (average):
Standard models............................................ 1500pfLow Capacitance models................................... 50pf
Operating Temperature....................... -40°C to +85°CWeight............................................................... 2.0 oz.Dimensions PC642 & PCB1B:
HxWxL............................................ 1.8" x 1.0" x 2.4"
Caution: The hybrid design of this product includesseries resistance. Do not place this product in serviceon any signal line capable of supplying more than 150milliamperes continuously.
¤ Wire wound resistors are used instead of "PTC's"on low capacitance models (PC642C-_ _ _ LC) andmodels clamping above 60 volts (PC642C-200, 200D,200X, 200LC).
DESCRIPTION:
2013 Utility Product Catalog Copyright © KENICK, Inc.
www.kenick.com800-362-9997
PM-850 Battery Back-up
DESCRIPTION SPECIFICATIONS
Features:• AutomaticVoltage Regulation• Dimensions 4.3”W x10.3”Dx8.9”H• Weight 16 lbs.• 5 Outlet BatteryBack-up +Surge• 4 Outlet Surge Only• 120 mins run time• Automaticshut-down software• UL1778 Listed
Surge + Battery Back-upSurge Only
VideoData Line
USB to Computer
The PM-850 Battery Back-up providesAVR (Automatic Voltage Regulation) sta-bilizes input voltage to an appropriatelevel for optimal equipment performanceby completely eliminating brownouts andovervoltages.
This smart unit provides battery back-upand surge protection to 5 outlets andsurge protection to an additional 4 out-lets that do not require constant power.With a set of in/out co-axial plugs aswell as a set of combo telephone/LANconnect plugs, you can be assured ofcomplete coverage to all connectedequipment. Also offers a USB/Serialconnection to a connected PC.
• Output Power Frequency when interrupted• Input Voltage Level• Output Voltage Level• AVR Status Meter• Battery Capacity• Estimated Runtime• Load Level
LCD Display Provides:
Voltage ..............................................90V - 140VFrequency ..........................................57 - 63 HzSurge Energy Capacity ......................890 JoulesMaximum Surge Current ................36,000 AmpsOutput Voltage on Battery....................120V ±5VOutput Frequency .......................................60Hz
2013 Utility Product Catalog Copyright © KENICK, Inc.
www.kenick.com800-362-9997
Features:• Single and Three Phase CriticalPowerSystems• Ideal forLargerorCriticalLoads• Online Design -No TransferTime• InverterOperatesContinuously• Pure Sinewave Output• Wide Input FrequencyWindow• TransistorPWMUtilizing IGBT• Shut-down SoftwareAvailable
SPECIFICATIONSDESCRIPTION
SIZES
Online UPS Systems
These UPS systems are designed for larger orvery critical loads. They are on line and providecomputer grade sine wave output to insure thehighest electronic equipment performance. Theyprovide complete voltage and frequency regula-tion and are emergency generator compatiblewithout going to battery.In larger buildings, harmonics are a concernwhenever a UPS is installed. With this UPS,input capacity equals output for retrofit installa-tion and harmonic filtering. They are designed topower nonlinear loads and act as an active har-monic filter.The UPS include comprehensive 3-Year Warran-ty with On·Site service including batteries! Theyhave an easy to read display of load, battery andUPS conditions (self diagnostics).Each UPS includes an automatic bypass forredundant protection.
SINGLE PHASE ON-LINE UPS systems are availableiin all popular sizes from 0.5 kVA to 18 kVA. Systemslarger than 2.0 kVA sizes: contact KENICK, Inc. forapplication information.
THREE PHASE ON-LINE UPS systems are availablein sizes ranging from 20 kVA to 500 kVA. 3 mVA par-allel systems are also available. Consult KENICK, Inc.for application information.
These specifications are common to most mod-els. Consult KENICK, Inc. for specific applicationinformation.
InputAll standard input voltages are available. Threephase UPS systems and some larger singlephase UPS systems without internal transformerrequire an input neutral conductor.
Voltage regulation........................+ l0% TO -30%Frequency reg.........50/60 Hz +- 5 Hz (45-65 Hz)Harmonic distortion..less than 5% THD (Current)Efficiency AC/DC/AC.................................. 89%
BatteryAll units use sealed maintenance free batteriesbelow 75 kVA size. Larger units can use eithersealed or stationary liquid batteries.Backup (Typical) 10 mins. @ Full Load/30 mins.@ Half LoadLife 8 Year Design
OutputAll standard output voltages are available.Transformer output units create their own outputneutral and have low common mode noise.
Voltage regulation .................± 3% ( 1% Typical)Frequency regulation.................50/60 Hz ± 0.1%(jumper selectable)THD (Linear Load).1 % (typical) ( 3% maximum)Crest Factor................................................... 3.0For more information, contact
KENICK 800-362-9997