40
Product catalogue August 2013

Product catalogue - ecofloor-bg.com · Fenix was founded in 1990 as one of the fi rst private companies in the Czech Republic following the “Velvet” Revolution. The fi rst items

  • Upload
    vanmien

  • View
    216

  • Download
    0

Embed Size (px)

Citation preview

Product catalogueAugust 2013

Fenix was founded in 1990 as one of the fi rst private companies in the Czech Republic following the “Velvet” Revolution. The fi rst items produced were the successfully marketed ECOSUN electric radiant heating panels, however, as market demand increased these products were followed by ECOFLEX electric convectors, ECOFLOOR heating cables and mats and ECOFILM heating fi lms. The company also offers a wide range of supplementary products including heating system controls, cable kits and cable mats. With the increase in demand the structure of the company developed – for the reason of retaining maximum fl exibility a holding company structure was chosen, with individual and independent members.

The following companies were incorporated successively: Fenix s.r.o. – plant producing electrical heating systems; Fenix Trading s.r.o. – trading company; Fenix Slovakia s.r.o. – production and trading company, representing FENIX in Slovakia; Fenix Group a.s. – a company which provides property management and services (strategic planning, administration of property, economic and fi nancial services); Flexel International Ltd. – manufacturing and trading company located in the United Kingdom. In 2008 FENIX Holding acquired the production and trading company Aztec Europe Ltd. – manufacturer of special applications, such as mirror demisting heaters, vivarium heaters, caravan and

ECOSUN – radiant heating panelslow and high temperature radiant ceiling panels

pages 4–6

MR – marble radiant panels for residential,commercial and individual applications

page 7

GR – glass radiant panels for residential, commercial and individual applications

pages 8–9

IRC PANELS – radiant heating for infrared cabins pages 10–11

ECOFLOOR – heating cable systemsheating cable circuits and cable mats, complete fl oor heating installation kits,

deicing gutter and eaves trough de-icing, snow melting, de-icing of outdoor surfaces, frost protection of pipes

pages 12–25

ECOFILM – heating fi lm systemsE-set – underfl oor heating, kit for DIY installation

F – underfl oor heating fi lmsC – radiant ceiling heating fi lms

MHF – mirror fogging preventionpages 26–29

ULTRATHERM – heating for vivariums and terrariums pages 30–31

ECOFLEX – electric convectorsclassic and glass convection heaters

pages 32–33

THERMOSTATS AND CONTROLSregulation units, control units, room and fl oor sensors,

and regulators for reduction of main circuit breaker valuepages 34–36

STORAGE HEATERSstatic and dynamic storage heaters

page 37

ATLANTIC – storage water heaters10 – 150 L volume

page 38

SUPPLEMENTARY PRODUCTShand dryers, towel radiators

page 38

mobile home heating equipment. At the end of 2009/in early 2010 Fenix Holding acquired two other production and trading companies: ACSO – production and trading company with its headquarters in France; CEILHIT –producer of heating cables and trading company with its headquarters in Spain, covering the market in Spain, Portugal and South America.

Presently, the company Fenix Holding s.r.o. is one of the largest European producers of surface electric heating systems, and currently exports to over 52 countries worldwide.

4

Principle of infrared heatingWhereas in convection heating the air is warmed by a convec-tor which then transfers heat as it flows over the objects that are to be heated (walls, furniture), Radiant heating panels transfer heat mainly through radiant energy. Upon encountering objects (walls, furniture, floors), radiant energy is partially reflected (ap-prox. 15 %) while the majority (approx. 85 %) is absorbed by the objects. This radiant energy is converted to heating energy as it raises the temperature of the objects, which then transfer heat to the cooler air by convection. Thanks to unique Silicating technology, high temperature radiant panels reach a high emissivity of up to 0.98 mu.

Unique technologiesFenix utilises unique state-of-the art technology in respect of the finished panel surfaces. (Thermoquartz and Thermocrystal for low temperature panels and Silicating for high temperature panels).

ECOSUN®

radiant heating panels

The principles mentioned create the following advantages:

the surface of the radiant panel generates a heat flow whose spectrum is in the wavelength not greater than 5 micrometers and is thus absorbed to a large degree by the human body: people are therefore heated in a manner similar to the objects in the room.

when the radiant heat flow increases the temperature of the objects in the room to 20–22 °C, comfort conditions are achieved even with air temperatures of 18–19 °C which can lead to energy savings of 18–24 %.

radiant panels permit the temperature distribution in a room to be more vertically balanced giving a 1–2 degree difference between the floor and the ceiling (for convection heating the difference is given as 1 °C per metre of height, 30–50 cm of height).

there is lower circulation of dust therefore dust particles due to Brownian motion, thus reducing the risk of illnesses – asthma, mucous membrane infection, etc.

increased wall temperatures mean a lower possibility of surface condensation, although the humidity in the room is not lowered.

glass is not “transparent” (we might say “transthermant”) when it comes to radiation with wavelengths over 3 and thus the radiant flow is not lost through windowpanes.

the panels do not require maintenance

Convection heatingRadiant heating by ECosun

5

LOW TEMPERATURE RADIANT PANELS

ECOSUN K+ – heating panel used for warming church pews, desks in offi ces and administrative buildings. They can be hung on a wall in the standard way; for installation on the ceiling it is necessary to order a ceiling frame. Class I.Basic colour: brown (0240), white (0100) Connection cable: 50 cm for 100–270 K+, 75 cm for 330–400K+

TYPE [W] [V] Rating Dimensions [mm] [kg] Recommended clearance [m] Qty on pallet Cat. No.ECOSUN 100 K+ 100

230 IP 44

500×320×30 2.5

vertical or horizontal position

60 5401200ECOSUN 200 K+ 200 750×320×30 3.7 45 5401205ECOSUN 270 K+ 270 1000×320×30 5.2 30 5401210ECOSUN 330 K+ 330 1250×320×30 6.6 30 5401215ECOSUN 400 K+ 400 1500×320×30 7.9 30 5401220Ceiling fi xing frame for ECOSUN 100 K+, 200 K+, 270 K+, 330 K+, 400 K+

TYPE [W] [V] Rating Dimensions [mm] [kg] Recommended clearance [m] Qty on pallet Cat. No.

ECOSUN 300 U 300

230 IP 44

592×592×30 5.0 from 2.5 m 40 5401037

ECOSUN 600 U 6001192×592×30

10.1 from 2.5 m 20 5401047

ECOSUN 700 U 700 10.5 from 2.7m 20 5401171

ECOSUN U – universal panel for living and non-living spaces, possibly mounted onto ceilings or into suspended ceilings. Class I. Basic colour: white (0100) Connection cable: 100 cm

TYPE [W] [V] Rating Dimensions [mm] [kg] Recommended clearance [m] Qty on pallet Cat. No.

ECOSUN 300 c 600/VT 300230 IP 20

574×574×35 4.6 min. 2.5 m 40 5401065

ECOSUN 600 c 600/VT 600 574×1174×35 9.4 min. 2.5 m 20 5401075

ECOSUN C/VT – heating panels only for mounting into suspended ceilings. Class I.Basic colour: white (0100)

ECOSUN G – a glass radiant panel derived from GR panels. Slim profi le – just 20 mm (panel with frame). The panel is supplemented with thermal insulation, with a frame from eloxed aluminium and versatile fi xtures which enable installation both on a wall (vertically) and on the ceiling (horizontally). This makes it a versatile product which combines the advantages of ECOSUN radiant panels and the design of GR glass panels. Protection class II; length of supply cables 2 m with plug connection. Option of installing on a class C or D fl ammable base.

TYPE [W] [V] Rating Dimensions [mm] Weight [kg] Recommended installation Quantity on pallet Cat. No.ECOSUN G 300 white 300

230 IP 44

600×600×50* 7

for ceiling min. 2.5 m, or on the wall

40 5437110ECOSUN G 600 white 600 1200×600×50* 14 20 5437112ECOSUN G 300 black 300 600×600×50* 7 40 5437116ECOSUN G 600 black 600 1200×600×50* 14 20 5437118ECOSUN G 300 mirror 300 600×600×50* 10.2 40 5437126ECOSUN G 600 mirror 600 1200×600×50* 19 20 5437128

* Thickness includes mounting fi xture, which is an inseparable part of the panel.

ECOSUN E – an alternative version of the ECOSUN G glass radiant panel. Slim profi le – just 20 mm (panel with frame).For this panel, the front glass has been substituted by a panel with a plastic powder coating; is suitable e.g. for health care applications. Protection class II; length of supply cables 2 m with plug connection. Option of installing on a class C or D fl ammable base.

TYPE [W] [V] Rating Dimensions [mm] Weight [kg] Recommended installation Quantity on pallet Cat. No.

ECOSUN E 300 white 300

230 IP 44

600×600×50* 6.6

for ceiling min. 2.5 m, or on the wall

40 5437140

ECOSUN E 600 white 600 1200×600×50* 11.3 20 5437142

* Thickness includes mounting fi xture, which is an inseparable part of the panel.

TYPE [W] [V] Rating Dimensions [mm] [kg] Recommended clearance [m] Qty on pallet Cat. No.

ECOSUN 700 IKP 700

230

IP 54 1192×592×30 9.3 2.5–3.0 20 5401176

ECOSUN 700 IN 700 IP 651192×592×30 9.5

2.8–3.3 20 5401181

ECOSUN 700 IN-2 700 IP 65 E Ex 2 3.0–3.5 20 5401186

Ceiling fi xing frame for type IKP, IN, IN-2

ECOSUN IKP, IN, IN-2 – panels for industrial and agricultural applications (i.e. in workshops, greenhouses, livestock facilities); for installation on the ceiling it is necessary to order a ceiling frame.. Class I. Basic colour: brown (0240) Connection cable: 100 cm

0100

0111

0240

0199

0215

0220

0230

0250

0440

0530

0565

0610

0620

0650

0660

0750

0819

0840

Col

ours

are

ava

ilabl

e to

ord

er (f

or a

n ad

ditio

nal f

ee)

Basic

6

HALOGEN HEATERSHalogen heaters – the high surface temperature of halogen tubes enables the use of the radiators in areas where normal radiant panels wouldn’t be effective – for example, in outdoor areas for the heating of terraces and balconies, or for the heating of large industrial halls with no heat cladding.

TYPE [W] [V] Rating Dimensions [mm] Weight [kg] Recommended clearance [m] Cat. No.

HWP 1500 1500

230

IP 55 480×120×120 1.7 2.2–3.0 m 8102010

HN 4500 4500IP 21

590×430×140 6.5 3.0–4.5 m 8102035

HN 6000 6000 590×430×140 6.5 3.5–5.5 m 8102040

HIGH TEMPERATURE RADIANT PANELSECOSUN S+ / S+Anticor – for industrial halls, gyms, halls, workshops, with a rating that corresponds to the given environment. Suitable for drying of buildings. Class I. Rating IP 44. Basic colour: white (RAL 9002). For spaces with higher humidity – agricultural structures, washing facilities, panels are produced in a corrosion-proof version. S+Anticor (RAL 9006).

TYPE [W] [V] Weight [kg] Quantity on pallet Recommended clearance [m] Dimensions [mm] Cat. No.ECOSUN S+ 06 short 600

2305.8 68

According to indi-vidual conditions,

for full area 5–8 m, zonal 3.4–4.5 m

650×250×605401537

ECOSUN S+ 08 short 850 5401538ECOSUN S+ 09 900

8.15 58 1550×150×605401540

ECOSUN S+ 12 1200 5401542ECOSUN S+ 18 1800

230 / 4002N

12.9 39 1550×250×605401544

ECOSUN S+ 24 2400 5401546ECOSUN S+ 30 3000

17.7 26 1550×350×605401548

ECOSUN S+ 36 3600 5401550ECOSUN S+ 09 Anticor 900

230 8.15 58 1550×150×605401552

ECOSUN S+ 12 Anticor 1200 5401554ECOSUN S+ 18 Anticor 1800

230 / 4002N

12.9 39 1550×250×605401556

ECOSUN S+ 24 Anticor 2400 5401558ECOSUN S+ 30 Anticor 3000

17.7 26 1550×350×605401560

ECOSUN S+ 36 Anticor 3600 5401562

TYPE Cat. No.

Tiltable bracket for ECOSUN S+ 5401785

Tiltable bracket for ECOSUN S+ Anticor 5401786

TILTABLE BRACKET – this tiltable bracket enables the installation of ECOSUN S+/Anticor panels at an angle, and thus the aiming of the heat fl ow at the required area. The bracket can be used for ceiling as well as wall installation; the package contains 1 pair of brackets (two pieces).

TYPE Cat. No.Protective grille for ECOSUN S+ 09–12 5401790Protective grille for ECOSUN S+ 18–24 5401792Protective grille for ECOSUN S+ 30–36 5401794

PROTECTIVE GRILLE – the protective grille protects the lamellas of ECOSUN S+ high-temperature panels against mechanical damage (for example, by a ball in a gym) and simultaneously prevents objects from coming into direct contact with the hot surface of the heating lamellas.

TYPE Cat. No.

Aluminium frame for ECOSUN 300U 5401228

Aluminium frame for ECOSUN 600U/700U 5401229

ALUMINIUM FRAME – is intended for ECOSUN panels and has a purely aesthetic function. The body of an ECOSUN panel is composed of two parts riveted together. Neither the gap formed by the connection of the front and rear parts nor the riveting itself are usually particularly visible in the case of ceiling installation. However, if required the panel can be fi tted with this aluminium frame, which covers the join.

– for industrial halls, gyms, halls, workshops, with a rating that corresponds to the given environment. NEW

7

MR PANELS – marble/granite radiant panels (thermo fuse), IP 44, class II; Connection cable for 300–1000:100 cm, 1200: 150 cm;Type of marble/granite: Madura, Kashmir, Volakas, Rosa, Verde;Needed clearance: lower edge 5 cm / top and side edge 15 cm / front side 50 cm

IP 44 TYPE OUTPUT [W] Dimensions [mm] Weight [kg] Quantity on pallet / in crate Cat. No.

Madura (beige)

300 500×500×30 23 10 / 22 5438282

500 700×500×30 32 10 / 20 5438283

800 900×600×30 49 5 / 11 5438284

1000 1100×600×30 65 5 / 11 54382851200 1300×600×30 77 5 / 7 5438286

Kashmir (creme)

300 500×500×30 22.5 10 / 22 5438292500 700×500×30 31 10 / 20 5438293

800 900×600×30 48 5 / 11 5438294

1000 1100×600×30 64 5 / 11 54382951200 1300×600×30 76 5 / 7 5438296

Volakas (white)

300 500×500×30 20 10 / 22 5438000500 700×500×30 28 10 / 20 5438005

800 900×600×30 43 5 / 11 5438010

1000 1100×600×30 53 5 / 11 54380151200 1300×600×30 62 5 / 7 5438020

Rosa (pink)

300 500×500×30 20 10 / 22 5438100500 700×500×30 28 10 / 20 5438105

800 900×600×30 43 5 / 11 5438110

1000 1100×600×30 53 5 / 11 54381151200 1300×600×30 62 5 / 7 5438120

Verde (green)

300 500×500×30 20 10 / 22 5438250500 700×500×30 28 10 / 20 5438255

800 900×600×30 43 5 / 11 5438260

1000 1100×600×30 53 5 / 11 5438265

1200 1300×600×30 62 5 / 7 5438270

MR marble panels are primarily intended for heating reception rooms, halls, bathrooms and other rooms.MR panels have an extremely aesthetic appearance and the ra-diant heat from this natural material is very acceptable. The MR panel consists of a robust polished marble/granite plate, a heating element, a limiting thermostat and a connection cable. This panel is intended to be installed as a fi xed installation on a wall with the connection cable connected to the installation box. These panels are manufactured in various power outputs and are available in 5 marble designs.As marble/granite is a natural material there is the possibility of small colour and texture variances.

MR – marble/granite radiant panels

RADIANT PANELS

TERRACE HEATERSECOSUN TerraceHeaters are designed for the zonal heating of winter gardens, enclosed and roofed balconies and terraces, garden tents, churches, etc. – i.e., applications where they are protected against direct contact with the effects of the weather. The min. height at which such panels can be installed is 1.8 m above the fl oor (the lower edge of the panel); for panels installed on the ceiling there must be a min. gap of 30 cm between the ceiling and the upper edge of the panel. 2 m cold lead with plug. Rating IP 44.

TYPE [W] [V] Weight [kg] Quantity on pallet Recommended clearance [m] Dimensions [mm] Cat. No.

TH 1000 1000

230

3.2 68

min. 1.8 m

1080×140×45 5401350

TH 1500 1500 4.4 68 1580×140×45 5401353

The min. height at which such panels can be installed is 1.8 m above the fl oor (the lower edge of the panel); for panels installed on the

NEW

8

NOTIFICATION

ECOSUN, MR and GR radiant panels are only equipped with a limiting thermostat – suitable regulation is essential for correct and eco-nomical operation; see the chapter THERMOSTATS AND CONTROLS. In the case of GR glass panels, the limiting thermostat switches off the panels at an average temperature of 90 °C, and therefore the real thermal output of the panels is approximately 10 % lower than the wattage. For this reason and also for the improvement of the dynamics of the whole heating system, we recommend that the installed wattage is increased by 20 % in contrast with the result of the heat loss calculation. GR panels can be supplemented with chromium-coated supports which enable the panel to be placed on the fl oor – e.g. in proximity to glass surfaces or to create a stylish portable heater.

GR glass radiant panels feature an attractive and timeless design. Due to their aesthetic appearance these panels are primarily in-tended for heating reception rooms, offi ces and other rooms. These glass panels consist of a 12 mm toughened glass plate heating element, a thermo fuse, a connection cable. They are designed to be mounted on a wall and connected to a wiring box by the connection cable.

GR – glass radiant panels

GR panels

GR PANELS – glass panels (thermo fuse), IP 44, class II; Connection cable: 100 cm; the panels are manufactured in 4 series with different outputs. GR panels are available in fi ve colours: mirror, white, black, red, yellow-green; Needed clearance: lower edge 5 cm / top and side edge 15 cm / front side 50 cm

TYPE Output [W] Dimensions [mm] Weight [kg]Quantity

on pallet / in crateGlass colour Cat. No.

GR 300 300 700×500×12 14 10 / 22 pcs

white, black, red, yellow-green

543760x

GR 500 500 900×600×12 21 5 / 12 pcs 543761x

GR 700 700 1100×600×12 26 5 / 12 pcs 543762x

GR 900 900 1200×800×12 38 5 / 8 pcs 543763x

GR 500 500 900×600×8 21 5 / 12 pcs

mirror

5437611

GR 900 900 1200×800×8 38 5 / 8 pcs 5437631

9

SUPPORTS FOR GR PANELS – for applications where the GR panel cannot be hung on a wall (e.g. in the case of glass surfaces), a set of chromium plated supports can be used for the placement of the panels on the fl oor.

The GR panel is inserted into apertures in the supports and subsequently the supports are affi xed to the panels with the help of adjustment screws. The panel is stable on these supports; the bottom edge of the panel is 55 mm above the fl oor. For permanent instal-lations, we recommend that the supports are attached to the fl oor using screws – in the base there are two openings with a diameter of 6 mm for screws with countersunk heads. The supports are intended for use only with the GR type and are only for horizontal installation. In the case of vertical installation (particularly for GR 900 panels), there is a signifi cantly higher risk that the user may accidentally knock the panel over. GR panels on supports must not be exposed to excessive pressure – there is a danger of tipping if it they are placed freely, and if the supports are attached to the fl oor, there is a risk of damage to the glass in the places where supports are attached.

PRODUCT Cat. No.Supports for GR panels Contents of the set: chromium plated supports – 2 pcs (base diameter 130 mm), plastic covers for the brackets for the GR panel – 4 pcs, mains plug (to be installed on the supply lead if the panel is to be used as a mobile heater)

8000100TYPE Description Weight [kg] Cat. No.

Simple towel rail (width 500 mm) GR 300 0.9 5437810Simple towel rail (width 600 mm) GR 500 and 700 1.05 5437812Simple towel rail (width 800 mm) GR 900 1.2 5437818Double towel rail (width 500 mm) GR 300 1.8 5437820Double towel rail (width 600 mm) GR 500 and 700 2.1 5437822Double towel rail (width 800 mm) GR 900 2.4 5437824

The rail is intended only for panels installed vertically; however, the installation itself is very easy. The openings in the back part of the rail are simply placed onto the top two screws of the panel by which the heater will be attached to the wall. The panel is then placed into the prepared hanging brackets. After the attachment nuts have been tightened, the rail, which is placed between the back part of the panel and the hanging bracket, is attached fi rmly. The rail is in the shape of a rectangle with the dimensions 530×90 mm; the distance between the attachment openings is 260 mm.

STAINLESS STEEL TOWEL RAIL – for GR 300, 500, 700 and 900 panelsThese towel rails are designed as an accessory for GR radiant glass panels in all colour versions. They are made from a 4×30 mm polished stainless steel sheet. After the installation of this rail, the standard panel is transformed into a smart bathroom heater with a rail on which a towel or bath towel can be hung.

10

IRC PANELS radiant heating for infrared cabins

The principle behind infrared cabins (infrared saunas)In infrared cabins (also called infrared saunas), so-called radiant heat is used – it works on a similar principle to ECOSUN heating panels. In this case, however, it is aimed at warming the muscle tissue of the user up to a depth of approximately 4 cm with the help of infrared radiation. Thanks to this deep warming of the organ-ism, intensive sweating takes places at a lower air temperature than in the case of classic steam saunas – during the whole of the user’s stay in the cabin, the air temperature ranges between 30 and approx. 55 °C.

Infrared cabins can be used over longer intervals, with the aim of freeing one’s body from harmful substances which are released when sweating, or in shorter intervals in which the aim is to warm up the muscle tissue before expected physical exercise – muscle stretching, body-building, running, etc.

Advantages of infrared cabins with IRC panels

Infrared heating warms up the skin faster and the heat also penetrates deeper into the tissues than heat from hot steam

Thanks to the lower air temperatures involved, they are also suitable for patients with cardiovascular diseases or respiratory diseases

In contrast with other types, they have considerably lower acquisition costs and minimum negative infl uences on the surrounding environment – humidity

The operating costs are lower by 1/3 to 1/2 in comparison with steam saunas (lower air temperature in the cabin; up to 80 % of the energy is used for direct heating of the body)

Large-surface IRC radiant panels heat evenly across their whole surface and for example in contrast with ceramic radiators, the output of which is concentrated into a small surface with a high temperature, they heat the whole body signifi cantly better and more evenly

The possibility of minimizing spatial requirements – a cabin can be installed in an area as small as 1 m2 – suitable also for smaller fl ats

Modular assembly without the necessity to use special tools in connection with the IRT regulator – the option of assembling the infrared cabin without expert assistance

11

CONTROL UNIT – IRT 01 REGULATOR – The IRT regulator maintains a set temperature on the surface of radiant panels, as well as the required operating time of the heating and lighting of the infrared cabin. It contains a power unit (installed within a cavity under the bench) to which IRC panels are connected using plugs, and also a control unit, light and supply cable. Up to 6 IRC panels can be connected. All IRC panels are equipped with a special connector and the offered sizes can be combined as needed; however, the total wattage mustn’t exceed 3.4 kW and one (only one) of the panels used must have an integrated temperature sensor. The power unit is connected to a 230 V socket, protected with a 30 mA residual current device.

IP 44IP 44 DESCRIPTION Cat. No.

IRT 01 REGULATORTemperature setting 20–80 °C; time setting 1 to 99 minutes; switch

Set contents: control unit including a connection cable; power unit with connectors; 3 m power cable with plug (230 V / 16 A); 3 m connection cable for lighting (light is not included in the set); instructions; screws – 8 pcs.

4200040

Set selection According to the size of the infrared cabin you wish to install, choose and combine the offered panel sizes in such a way that they best cover the space within the infra-red cabin – the lower and upper halves of the body. It is ideal if the panels surround the user on at least three sides.

There can be a maximum of six panels for every control unit, from which one (but only one) must be equipped with an integrated temperature probe. The maximum wattage of all the panels attached to one control unit can be up to 3.4 kW.

An IRT-01 regulator is necessary to control the panels. The regulator comes with the set, which includes a control panel and power unit. The control panel should be installed inside the infrared cabin within reach of the user. The power unit is installed in a cavity under the bench and should not be easy to access.

The connecting leads for the IRC panels are, after installation on the wall, connected to the power unit with the aid of connectors – the connectors from the panels, lighting, control units and connecting leads have different dimensions, so it isn’t possible to confuse them and connection can be carried out by a non-expert user.

If lighting is required it is also possible to connect a light to the power unit; a connection cable comes as part of the set.

It is necessary to equip panels with a suitable protective cover, allowing the correct operation of the panel.

The wooden frames not only fulfi l a protective function, but also attach the panels to the walls – the panels themselves are not fi tted with any mounting apertures or brackets.

IRC RADIANT PANELS – FENIX has manufactured and supplied IRC panels for foreign producers of infrared cabins (Austria, Germany) since 2004. Now it is offering these panels on the Czech market together with a control unit – IRT regulator – and this also as a DIY kit.

IP 44 PRODUCT Output [W] Voltage [V] Weight [kg] Dimensions [mm] Cat. No.

IRC Panel 1130x360/200 200

230

3.9 875x360 5401805IRC Panel 1130x360/260 260 5.2 1130×360 5401810IRC Panel 1330x360/310 310 6.1 1330x360 5401811IRC Panel 650x780/330 330 5.8 650x780 5401813IRC Panel 1130x780/575 575 10.1 1130×780 5401812IRC Panel 1130x780/575 S (with a probe) 575 10.2 1130×780 5401814IRC Panel 1330x780/680 S (with a probe) 680 12.5 1330×780 5401815cold lead 2 m

12

ECOFLOOR®

underfl oor heating systems

ASL1P cableLD heating mats

ADSV-T cableLDTS, LSDTS heating mats

ADSV cableADSV heating circuits

ADSV+ cableADSV+ heating circuits

ADSA cableCM ultrathin mats

Overview of ECOFLOOR heating cables and recommended usage

ECOFLOOR electric fl oor heating systems ensure ideal heat distri-bution and, by decreasing undesirable air circulation, reduce dust levels. These systems offer great comfort, economic and reliable operation, and long lifetime. They preserve free fl oor space by eliminating the need for various heating elements, radiators and heat distribution systems. The principal advantage of electric fl oor heating is easy and separate temperature control in individual rooms. Once installed, it is completely maintenance free.We provide a 10 year warranty for underfl oor heating cables and mats and a 2 year warranty for cables used in outdoor applications (gutter, eaves, pipes).

*) for a short term (installation under asphalt)

Type

Watta

ge [W

/m]

Numb

er of

heati

ng co

res

Protec

tive s

creen

Protec

tion a

gains

t UV r

adiat

ion

Therm

al en

duran

ce of

the ja

cket

Supp

lied a

s circ

uit

Supp

lied a

s mat

Floor heatingAnti-freeze

protection of

Direct

-heati

ng

Semi

-stora

ge

Storag

e

Surfa

ces

Roofs

Pipes

ASL1P10

1

70 °C

15

18

ADSV10

2

70 °C

15

18

ADSV-T 12 2 70 °C

ADSV+10

2

80 °C

18

20

ADSA 12 2 70 °C

ADPSV10

2

80 °C

18

20

PSV10

1

70 °C

15

MAPSV20

1

80 °C

25

30

MADPSP

15

2

90 °C240 °C*

20

25

30

PDSP 28 2 90 °C

200 °C*

PFP 12 2 70 °C

PDS1P 40 2 70 °C

13

Overview of ECOFLOOR heating mats and recommended usage

Overview of special ECOFLOOR heating cables and recommended usage

PSV cablePSV heating circuits, LPSV heating mats

ADPSV cableADPSV heating circuits

MAPSV cableMAPSV heating circuits, MST heating mats

MADPSP cableMADPSP heating circuits, MDT heating mats

PDSP cablePDSP heating circuits

PDS1P cablefor curing concrete

Type

Watta

ge [W

/m]

Numb

er of

heati

ng co

res

Protec

tive s

creen

Protec

tion a

gains

t UV r

adiat

ion

Therm

al en

duran

ce of

the ja

cket

Supp

lied a

s circ

uit

Supp

lied a

s mat

Floor heatingAnti-freeze

protection of

Direct

-heati

ng

Semi

-stora

ge

Storag

e

Surfa

ces

Roofs

Pipes

ELSR-M10

2

65 °C

15

ELSR-N20

2

80 °C

30

PCC 30 1 −40…60 °C

PC25

2 −50…60 °C

50

PC-S20

2

−50…60 °C

25

PCC cableheating circuits for anti-freeze protection –heating of the insulating door seals of freezers

ELSR-M cableself-regulating cable for anti-freeze protection and technological heating (10 and 15 W/m)

PC cableheating cable with a constant linear wattage for anti-freeze protection and process heating

ELSR-N cableself-regulating cable for anti-freeze protection and technological heating (20 and 30 W/m EExII)

PC-S cablearmoured heating cable (metal braiding)with a constant linear wattage for anti-freeze protection and process heating

Type

Watta

ge [W

/m]

Numb

er of

heati

ng co

res

Protec

tive s

creen

Protec

tion a

gains

t UV r

adiat

ion

Therm

al en

duran

ce of

the ja

cket Floor heating

Heati

ng of

outdo

or are

as

Type o

f hea

ting c

able

Direct

-heati

ng

Semi

-stora

ge

Storag

e

CM 150 2 90 °C ADSA

LDTS80

2

70 °C

ADSV-T100

160

LD 160 1 70 °C ASL1P

LSDTS100

2

70 °C

ADSV-T160

LPSV 100 1 80 °C PSVMST 300 1 80 °C MAPSVMDT 300 2 90 °C MADPSP

AL-MAT80

2

70 °C

A2140

Cable composition markings

1 Resistance (heating) wire

M multi-resistance – stranded resistance wire (to be used for higher outputs);

no letter is used for a non-stranded (simple) resistance wire

2 Core insulation

A FEP (fl uoropolymer)

P XLPE (cross-linked polyethylene)

3 Number of heating cores

D double-core cable;no letter is used for a single-core cable

4 Plastic insulation (for outdoor applications, higher mechanical ruggedness of cable)

P XLPE (cross-linked polyethylene);no letter is used for a cable without the second plastic insulation

5 Protection screen (for wet areas)

S full screen protection (tinned copper wires and aluminium tape)

SL linear screen protectionno letter is used for a cable without screen protection

6 Jacket

P XLPE (cross-linked polyethylene)

1P PP-LDPE (mixed polypropylene & low density PE)

V PVC (polyvinyl chloride)

1 2 3 4 5 6

M A D P S P

Linear input of cable [W/m]

Total input of circuit [W]

2 0 2 4 0

14

DIRECT HEATING SYSTEM1 wear layer (ceramic fl oor tiling)2 fl exible bonding cement3 ECoFLooR® heating mat4 fl oor (limitation) probe in a protective tube (so-called goose neck)5 load-bearing concrete fl oating board6 steel reinforcement (so-called Kari mesh)7 thermal insulation8 base (concrete board)

DIRECT HEATING SYSTEMSECOFLOOR CABLES AND MATS

ECOFLOOR heating systems are available in two basic variants – heating cable circuits and heating mats. In fact the two systems do not differ from one another very much. In both cases, the heating system consists of a heating cable, either separate or fi xed to a supporting fi breglass cloth (heating mat). This modern fl oor heating system permits easy and effective regulation. The heating cable circuits or mats are placed directly beneath tiles in a thin layer of permanently fl exible cement so the tiled surface heats up relatively quickly (approx. 20 min). Temperature control is sensitive and quick to react. Heating cable circuits or mats are suitable for renovated fl oors where the fi nal fl oor height is not a constraint.

DIRECT HEATING SYSTEM—RECONSTRUCTION1 wear layer (ceramic fl oor tiling)2 fl exible bonding cement3 heating mat (cable) ECoFLooR®

4 fl oor (limitation) probe in a protective tube (so-called goose neck)5 F-BoARD supplementary thermal insulation

(shortens the warming time) (see page 25)6 fl exible bonding cement7 original fl oor (old fl oor tiling, concrete)

15

LDTs / LsDTs heating matLDTs / LsDTs packing

ECOFLOOR Installation – Heating Mat1) Unroll the heating mat according to the layout drawing.2) If you need to leave a space under fi xed furniture, cut out the necessary part of the cloth and span the space with the cable (see fi g. 2).3) Level the layer of fl exible cement with a smooth trowel.4) Lay tiling on small areas (up to 4 m2) immediately, and on larger areas after 24 hours.

ECOFLOOR HEATING MATS

LDTS 80 W/m2

OUTPUT [W]

Type80 W/m2

Surface [m2]

Length [m]

Cat. No.LDTS

60 80/0.8 0.8 1.5 5531502105 80/1.3 1.3 2.6 5531504180 80/2.3 2.3 4.5 5531506220 80/2.8 2.8 5.5 5531508290 80/3.6 3.6 7.2 5531510410 80/5.1 5.1 10.2 5531512460 80/5.8 5.8 11.5 5531514560 80/7.0 7.0 14.0 5531516820 80/10.3 10.3 20.5 5531518

1000 80/12.5 12.5 25.0 55315201200 80/15.0 15.0 30.0 55315221800 80/22.5 22.5 45.0 5531524

LDTS 160 W/m2

OUTPUT [W]

Type160 W/m2

Surface [m2]

Length [m]

Cat. No.LDTS

80 160-0.5 0.5 1.0 5540001160 160-1 1.0 2.0 5540002240 160-1.5 1.5 3.0 5540003320 160-2 2.0 4.0 5540004400 160-2.5 2.5 5.0 5540005480 160-3 3.0 6.0 5540006560 160-3.5 3.5 7.0 5540007640 160-4 4.0 8.0 5540008800 160-5 5.0 10.0 5540009960 160-6 6.0 12.0 5540010

OUTPUT [W]

Type160 W/m2

Surface [m2]

Length [m]

Cat. No.LDTS

Cat. No.LSDTS

70 160/0.5 0.5 0.9 5530200 5531005130 160/0.8 0.8 1.6 5530205 5531010210 160/1.3 1.3 2.6 5530210 5531015260 160/1.6 1.6 3.2 5530220 5531020340 160/2.1 2.1 4.2 5530230 5531025410 160/2.6 2.6 5.2 5530240 5531030500 160/3.0 3.0 6.0 5530250 5531035560 160/3.4 3.4 6.7 5530255 5531040670 160/4.2 4.2 8.3 5530260 5531045810 160/5.1 5.1 10.2 5530270 5531050

1000 160/6.1 6.1 12.3 5530280 55310551210 160/7.6 7.6 15.1 5530290 55310601400 160/8.8 8.8 17.6 5530190 55310801800 160/11.0 11.0 22.0 5530192 55310852150 160/13.3 13.3 26.6 5530194 55310902600 160/16.3 16.3 32.5 5530196 5531095

LDTS / LSDTS 160 W/m2

LDTS or LSDTS (self-adhesive) heating mat, twin conductor cable with a full protection screen, width 50 cm, cold lead 1×3 m. LDTS mats are provided with self-adhesive tape for affi xing to the fl oor. LSDTS mats have a self-adhering mesh on their entire back surfaces.

OUTPUT [W]

Type100 W/m2

Surface [m2]

Length [m]

Cat. No.LDTS

Cat. No.LSDTS

60 100/0.6 0.6 1.2 5530401 5531105 105 100/1.0 1.0 2.1 5530403 5531110 180 100/1.8 1.8 3.6 5530405 5531115 220 100/2.2 2.2 4.4 5530410 5531120 290 100/2.9 2.9 5.8 5530415 5531125 410 100/4.1 4.1 8.2 5530420 5531130 460 100/4.7 4.7 9.4 5530425 5531135 560 100/5.6 5.6 11.2 5530430 5531140 820 100/8.2 8.2 16.5 5530440 5531145

1000 100/10.2 10.2 20.3 5530450 5531150 1200 100/11.8 11.8 23.7 5530460 5531155 1800 100/17.9 17.9 35.8 5530470 5531160

LDTS / LSDTS 100 W/m2

LD matPacking in PE foil.LD matPacking in PE foil.

LD heating mat, single conductor cable with a full protection screen, width up to 3 m2 – 30 cm, over 3 m2 – 50 cm, cold lead 2×5 m

OUTPUT [W]

Type LD160 W/m2

Surface [m2]

Width [m]

Length [m] Cat. No.

100 160/0.6 0.6 0.3 2.0 5530005150 160/0.9 0.9 0.3 3.0 5530007180 160/1.1 1.1 0.3 3.6 5530010300 160/1.8 1.8 0.3 6.1 5530020360 160/2.3 2.3 0.3 7.6 5530030500 160/3.0 3.0 0.3 10.0 5530040700 160/4.3 4.3 0.5 8.6 5530050850 160/5.3 5.3 0.5 10.6 5530060950 160/5.9 5.9 0.5 11.8 55300701150 160/7.2 7.2 0.5 14.4 55300801700 160/10.7 10.7 0.5 21.4 55300902000 160/12.4 12.4 0.5 24.9 55301002500 160/15.7 15.7 0.5 31.3 55301103000 160/18.8 18.8 0.5 37.6 5530120

LD 160 W/m2

ULTRA THIN CM MATS – a very thin two conductor cable with a protective screen – suitable for damp areas (bathrooms, laundry rooms) as well as for standard rooms – ideal for placement into adhesive sealing cement directly under floor tiling; Ø of cable 2.4–2.7 mm, cold lead – 1×2.5 m.

CM 150 W/m2

OUTPUT [W] Type Surface

[m2]Length

[m] Cat. No.

150 CM150/1 1.0 2.0 5540103225 CM150/1.5 1.5 3.0 5540105300 CM150/2 2.0 4.0 5540107375 CM150/2.5 2.5 5.0 5540109450 CM150/3 3.0 6.0 5540111600 CM150/4 4.0 8.0 5540113750 CM150/5 5.0 10.0 5540115

120 W/m2 and 150 W/m2 LDTS heating mats are also available.

16

ADSV heating cable, a twin conductor cable with a full protection screen suitable for wet areas. For direct fl oor heating or fl oor renovation (installation under tiles). Cable diameter 3.6–4.6 mm.Cold lead 1×3 m.

ECOFLOOR HEATING CABLE CIRCUITS

OUTPUT [W]

Type ADSV10 W/m

LENGTH [m] Cat. No.

65 10065 6.6 2232100120 10120 11.4 2232105200 10200 18.9 2232110250 10250 23.6 2232115320 10320 31.6 2232120400 10400 36.9 2232125450 10450 45.9 2232130520 10520 49.6 2232135600 10600 63.9 2232140750 10750 75.8 2232145950 10950 87.0 22321501100 101100 114.5 22321551300 101300 131.3 22321601700 101700 158.5 22321652000 102000 194.5 2232170

OUTPUT [W]

Type ADSV15 W/m

LENGTH [m] Cat. No.

80 15080 5.4 2242405140 15140 9.8 2242407240 15240 15.7 2242410300 15300 19.7 2242415400 15400 25.3 2242420470 15470 31.4 2242425550 15550 37.4 2242430630 15630 41 2242435750 15750 51.1 2242440950 15950 59.9 22424451100 151100 75.1 22424501350 151350 93.3 22424551600 151600 106.7 22424602400 152400 162.1 2242465

OUTPUT [W]

Type ADSV18 W/m

LENGTH [m] Cat. No.

160 18160 8.50 2243120260 18260 14.50 2243125320 18320 18.50 2243130420 18420 24.00 2243135520 18520 28.40 2243140600 18600 34.4 2243145680 18680 37.9 2243150830 18830 46.1 2243155

1000 181000 57.5 22431601200 181200 68.9 22431651500 181500 83.2 22431701700 181700 100.4 22431752200 182200 122.7 22431802600 182600 149.6 2243185

TYPE(Ohm/m) Cat. No.

122.5 200151038.72 200151514.020 20015208.960 20015255.232 20015303.584 20015352.568 20015402.050 20015451.382 20015500.926 20015550.638 20015600.424 20015650.310 20015700.196 20015750.136 2001580

Cables on drums Heating circuits

Cold lead 1×3 m.

OUTPUT [W]

Type ASL1P10 W/m

LENGTH [m] Cat. No.

160 10160 17.0 2200160280 10280 27.0 2200280350 10350 33.7 2200350450 10450 45.0 2200450640 10640 64.0 2200640800 10800 77.2 2200800960 10960 80.0 22009601100 101100 103.9 22011001600 101600 156.0 22016001900 101900 179.6 22019003000 103000 259.3 2203000

OUTPUT [W]

Type ASL1P15 W/m

LENGTH [m] Cat. No.

200 15200 13.7 2201000340 15340 22.2 2201005420 15420 28.1 2201010550 15550 36.8 2201015800 15800 51.5 2201020960 15960 64.3 2201025

1070 151070 71.5 22010301300 151300 87.9 22010351900 151900 131.3 22010402200 152200 155.1 22010453400 153400 228.8 2201055

OUTPUT [W]

Type ASL1P18 W/m

LENGTH [m] Cat. No.

210 18210 11.9 2201060350 18350 19.7 2201062450 18450 24 2201064570 18570 32.5 2201066820 18820 46 2201068

1000 181000 56.5 22010701100 181100 63.7 22010721400 181400 74.7 22010742000 182000 114.2 22010762400 182400 130.1 22010783000 183000 164.6 22010803500 183500 203.4 2201082

Cables on drumsTYPE

(Ohm/m) Cat. No.

61.25 200517827.13 200517919.36 20051807.010 20051814.480 20051822.616 20051831.284 20051850.857 20051870.691 20051880.463 20051900.212 20051920.155 20051930.068 2005195

Heating circuits

ECOFLOOR Installation – Heating Cable Circuit1) Create loops of the heating cable across the entire base (a spacing guide may be used, as shown).2) Fix the cable to the base using the self-adhesive tape or GRUFAST fastening strips.3) Level the layer of fl exible cement with a smooth trowel.4) Lay tiling on small areas (up to 4 m2) immediately, and on larger areas after 24 hours.

Cable on drum Cable circuit on a cardboard reel.standard packing. Packing in cardboard

box available

ASL1P heating cable, a single-conductor cable with a full protection screen suitable for wet areas. For direct fl oor heating (installation under tiles).

Cold lead 2×5 m. Cable diameter 2.9–3.6 mm. Packed in PE foil.

17

It is recommended that you install F-Board insulated tile backer board before laying ComfortMat. This will ensure quicker warm up times and reduce running costs (see page 25).

Kits for do-it-yourself installation have been designed for those users who do not want a complete electrical heating system but a comfortable, warm fl oor in a specifi c area (e.g. bathroom or kitchen). The kits include everything needed to install the fl oor heating system and are very reasonably priced.

ECOFLOOR ComfortMat

KITS FOR DO-IT-YOURSELF INSTALLATION

OUTPUT [W]

Type CM160 W/m2

AREA[m2]

LENGTH [m] Cat. No.

70 12070-165 0.5 0.9 5590094

130 12130-165 0.8 1.6 5590097

210 12210-165 1.3 2.6 5590100

260 12260-165 1.6 3.2 5590105

340 12340-165 2.1 4.2 5590110

410 12410-165 2.6 5.2 5590115

500 12500-165 3.0 6.1 5590120

560 12560-165 3.4 6.7 5590122

670 12670-165 4.2 8.3 5590125

810 12810-165 5.1 10.2 5590130

1000 121000-165 6.1 12.3 5590135

1210 121210-165 7.6 15.1 5590140

1400 121400-165 8.8 17.6 5590145

OUTPUT [W]

Type CM100 W/m2

AREA[m2]

LENGTH [m] Cat. No.

180 8180-105 1.9 3.6 5590148220 8220-105 2.2 4.4 5590150290 8290-105 2.9 5.8 5590152410 8410-105 4.1 8.2 5590155460 8460-105 4.7 9.4 5590157560 8560-105 5.6 11.2 5590160820 8820-105 8.2 16.5 5590165

Width of the heating mat is 50 cm

Comfort mat includes LDTS heating mat TFT digital touch screen thermostat protective tube for fl oor sensor installation manual

AL MAT heating mats are intended for use under laminate and wooden fl oating fl oors installed in so-called moist areas – in bathrooms, for example. They are a variant of ECOFILM heating foils designed for applications where ECOFILM foils cannot be used. The mat is of the two-core type, with one 3m long connecting cable; the thickness of the mat is only 1.7 mm.

AL MAT

OUTPUT [W]

Type AL MAT140 W/m2

AREA[m2]

LENGTH [m] Cat. No.

140 AL MAT 140/1 1 2 5543000210 AL MAT 140/1,5 1.5 3 5543002280 AL MAT 140/2 2 4 5543004560 AL MAT 140/4 4 8 5543008840 AL MAT 140/6 6 12 55430101120 AL MAT 140/8 8 16 55430121400 AL MAT 140/10 10 20 5543014

OUTPUT [W]

Type AL MAT80 W/m2

AREA[m2]

LENGTH [m] Cat. No.

100 AL MAT 80/1,25 1.25 2.5 5543200160 AL MAT 80/2 2 4 5543202240 AL MAT 80/3 3 6 5543204400 AL MAT 80/5 5 10 5543206640 AL MAT 80/8 8 16 5543208800 AL MAT 80/10 10 20 5543210960 AL MAT 80/12 12 24 5543212

AL MAT 140 W/m2, cold lead 3 m

AL MAT 80 W/m2, cold lead 3 m

NEW

18

STORAGE ECOFLOOR HEATING1 wear layer (fl oor tiles, carpet, PVC, laminate)2 fl oor (limitation) probe in a protective tube (so-called goose neck)3 concrete storage layer4 ECoFLooR® heating mat (cable)5 concrete storage layer6 steel reinforcement (so-called Kari mesh)7 thermal insulation8 base (concrete board)

SEMI-STORAGE SYSTEM1 wear layer (fl oor tiling, carpet, PVC, laminate)2 fl oor (limitation) probe in a protective tube (so-called goose neck)3 load-bearing concrete fl oating board4 steel reinforcement (so-called Kari mesh)5 ECoFLooR® heating mat (cable)6 thermal insulation7 base (concrete board)

SEMI-STORAGE AND STORAGE HEATINGECOFLOOR CABLES AND MATS

Heating cables or mats in semi-storage systems are placed in a layer of concrete 4–5 cm thick. The mat’s recommended output wattage is 160 W/m2. Heat is accumulated for 16 hours a day at a time when electricity costs are lowest. The accumulated heat is radiated from the fl oor surface not only during the process, but also for a further 8 hours. One effi cient solution is to divide the total desired heating system 70/30 between the fl oor heating and another source, such as a convection heater or an ECOSUN radiant panel.

Storage fl oor heating is a system that takes advantage of cheaper electricity tariffs – usually at night. During this time, heat is accumulated into the mass of the fl oor using ECOFLOOR electrical heating cables or mats. Throughout the rest of the day, the heat is gradually released from the fl oor to the room. In storage systems, heating mats or cables are placed in a layer of concrete 10 to 14 cm thick. The accumulated—stored—heat is then released during the day into the area to be heated. We recommend an output wattage of 250 to 300 W/m2 for ECOFLOOR mats used in this type of system. Eight hours of low-tariff electricity should be used to accumulate the heat.

base (concrete board)

19

PSV cable circuita single-conductor cable with 2×5 m cold leads.Packed in cardboard box.

OUTPUT [W]

Type PSV 15 W/m

LENGTH [m] Cat. No.

200 15200 13.7 2320110340 15340 22.2 2320115420 15420 28.1 2320120550 15550 36.7 2320125660 15660 44.7 2320130800 15800 52.3 2320135880 15880 58.6 2320140960 15960 64.1 2320145

1070 151070 71.5 23201501210 151210 81.0 23201551300 151300 84.1 23201601580 151580 104.6 23201651900 151900 128.6 23201702200 152200 150.3 23201752800 152800 189.4 23201803400 153400 227.5 2320185

PSV heating cable, a single-conductor cable with a full protection screen for storage and semi-storage heating.

Cold lead 2×5 m. Cable diameter 4.5–5.1 mm.

TYPE(Ohm/m) Cat. No.

19.36 20012107.01 20012154.48 20012202.616 20012251.792 20012301.284 20012351.025 20012400.857 20012450.691 20012500.54 2001255

0.463 20012600.319 20012650.212 20012700.155 20012750.098 20012800.068 2001285

Cables on drumsOUTPUT

[W]Type PSV 10 W/m

LENGTH [m] Cat. No.

170 10170 16.1 2320020280 10280 28.0 2320025350 10350 34.0 2320030450 10450 46.0 2320035550 10550 53.7 2320040640 10640 64.4 2320045720 10720 71.7 2320050800 10800 79.1 2320055870 10870 88.0 2320060960 10960 100.0 23200651100 101100 106.8 23200701280 101280 129.6 23200751600 101600 157.9 23200801900 101900 189.6 23200852500 102500 234.7 23200903000 103000 277.8 2320095

Heating circuits

OUTPUT [W]

Type ADPSV 18 W/m

LENGTH [m] Cat. No.

160 18160 8.5 2249960260 18260 14.5 2249963320 18320 18.5 2249966420 18420 24.0 2249969520 18520 28.4 2249972600 18600 34.4 2249975740 18740 41.8 2249976830 18830 46.1 2249978

1000 181000 57.5 22499811200 181200 68.9 22499841500 181500 83.2 22499871700 181700 100.4 22499902200 182200 122.7 22499922600 182600 149.6 2249993

LPSV heating mat, single conductor cable with a full protection screen, width 50 cm, cold lead 2×5 m. Packed on a cardboard tube and sealed in PE foil.

ADPSV cable circuita twin conductor cable

ADsV+, ADPsV packing

OUTPUT [W]

Type LPSV100 W/m2

Surface [m2]

Length [m] Cat. No.

180 LPSV 1.8 1.8 3.6 5520352300 LPSV 3 3.0 6.0 5520354370 LPSV 3, 3.7 7.4 5520356480 LPSV 3.7 4.8 9.6 5520358580 LPSV 5.8 5.8 11.6 5520360700 LPSV 7 7.0 14.0 5520362770 LPSV 7.7 7.7 15.4 5520364850 LPSV 8.5 8.5 17.0 5520366940 LPSV 9.4 9.4 18.8 5520368

1050 LPSV 10.5 10.5 21.0 55203701150 LPSV11.5 11.5 23.0 55203721400 LPSV 14 14.0 28.0 55203741700 LPSV 17 17.0 34.0 55203762000 LPSV 20 20.0 40.0 55203782500 LPSV 25 25.0 50.0 5520380

ADPSV heating cable, a twin conductor cable with a full pro-tection screen suitable for semi-storage and storage fl oor heating in living areas. Class M2. Cold lead 1×5 m. Ø 5.0–5.9 mm.

ADSV+ heating cable, a two-conductor cable with a full protection screen. The sheathing of the cable is resistant against UV radiation and is intended for fl oor heating and the removal of snow and ice from roofs and eaves troughs. 1×3 m cold lead. Ø 5.0 mm.

OUTPUT [W]

Type ADSV+18 W/m

LENGTH [m] Cat. No.

160 18160 8.5 2253100260 18260 14.5 2253105320 18320 18.5 2253110420 18420 24.0 2253115520 18520 28.4 2253120600 18600 34.4 2253125680 18680 37.9 2253130830 18830 46.1 2253135

1000 181000 57.5 22531401200 181200 68.9 22531451500 181500 83.2 22531501700 181700 100.4 22531552200 182200 122.7 22531602600 182600 149.6 2253165

OUTPUT [W]

Type ADSV+ 10 W/m

LENGTH [m] Cat. No.

120 10120 11.4 2253000200 10200 18.9 2253005250 10250 23.6 2253010320 10320 31.6 2253015400 10400 36.9 2253020450 10450 45.9 2253025520 10520 49.6 2253030600 10600 63.9 2253035750 10750 75.8 2253040950 10950 87.0 22530451100 101100 114.5 22530501300 101300 131.3 22530551700 101700 158.5 22530602000 102000 194.5 2253065

Heating circuits

Packing in cardboard box available

20

OUTDOOR APPLICATIONS

Ice and snow melting Installing electric heating cables in outdoor areas, together with a thermostat, prevents both ice formation and snow accumulation. Once installed, the system works entirely automatically and is only operational when it is snowing or if ice is forming on roads and walkways.

De-icing gutters and eaves troughsIn all parts of Europe other than in the south, winter brings a heavy load to many buildings as ice builds up in the gutters and eaves troughs. Installing an ECOFLOOR electric heating cable (with a protective screen) into gutters and eaves troughs is a good solution for such problems. The cables are installed using special plastic clips placed inside gutters and eaves troughs. We recommend a linear wattage of 20 W/m for the de-icing cables.

Frost protection of pipesMany homeowners and other users of piping have many troubles in the winter due to freezing pipes. This especially applies to water pipes, but other liquids used in industrial processes can also freeze or solidify. During long spells of below-freezing temperatures, even very well-insulated piping can freeze. Supplementary heating is a reliable preventive solution.

21

MAPSV heating cable, a single-conductor cable with a full protec-tion screen and protection against UV radiation. Suitable for heating outdoor surfaces. Cold lead 2×5 m. Ø 5.0–5.5 mm.

MAPSV cables 400 VOUTPUT

[W]Type MAPSV

20 W/m – 400 VLENGTH

[m] Cat. No.

600 20600 29.6 2322650700 20700 35.2 2322652

1000 201000 50.0 23226541550 201550 76.5 23226561800 201800 88.9 23226582300 202300 115.9 23226603000 203000 148.1 23226623500 203500 182.9 23226644200 204200 208.2 23226664600 204600 224.4 23226685800 205800 281.5 23226707000 207000 336.1 23226729000 209000 444.4 2322674

OUTPUT [W]

Type MAPSV 30 W/m – 400 V

LENGTH [m] Cat. No.

730 30730 24.4 2322700850 30850 29.0 2322702

1230 301230 40.7 23227041900 301900 62.4 23227062200 302200 72.7 23227082800 302800 95.2 23227103700 303700 120.1 23227124400 304400 145.5 23227145100 305100 171.4 23227165600 305600 184.3 23227187000 307000 233.2 23227208500 308500 276.8 232272211000 3011000 363.6 2322724

OUTPUT [W]

Type MAPSV20 W/m

LENGTH [m] Cat. No.

340 20340 17.3 2322500400 20400 20.3 2322502570 20570 29.0 2322504880 20880 44.5 2322506

1030 201030 51.4 23225081350 201350 65.3 23225101750 201750 84.0 23225122100 202100 100.8 23225142400 202400 120.4 23225162600 202600 131.3 23225183300 203300 163.6 23225204000 204000 194.5 23225225100 205100 259.3 2322524

OUTPUT [W]

Type MAPSV 30 W/m

LENGTH [m] Cat. No.

420 30420 14.0 2322600500 30500 16.3 2322602700 30700 23.6 23226041100 301100 35.6 23226061250 301250 42.3 23226081600 301600 55.1 23226102100 302100 70.0 23226122500 302500 84.6 23226142950 302950 98.0 23226163200 303200 106.7 23226184000 304000 134.9 23226204800 304800 162.1 23226226300 306300 209.9 2322624

OUTPUT [W]

Type MAPSV 25 W/m

LENGTH [m] Cat. No.

380 25380 15.5 2322550450 25450 18.1 2322552640 25640 25.8 2322554990 25990 40.0 23225561150 251150 46.0 23225581480 251480 59.6 23225601900 251900 77.3 23225622300 252300 92.0 23225642700 252700 107.1 23225662900 252900 117.1 23225683700 253700 145.9 23225704400 254400 176.8 23225725700 255700 232.0 2322574

TYPE(Ohm/m) Cat. No.

9.00 20008506.50 20008523.20 20008541.35 20008561.00 20008580.60 20008600.36 20008620.25 20008640.183 20008660.155 20008680.098 20008700.068 20008720.04 2000874

Cables on drums Heating circuits 230 V

MST mats, 230 V, width 0.5 m

MST mats available also in 1m width. For easy installation MST heating mats are provided with a 1×5 m cold lead and another 1×5 m cold lead + the length of the mat. Cables and mats are packed in PE foil.

OUTPUT [W]

Type MST 300 W/m2

AREA [m2]

LENGTH [m] Cat. No.

450 23MST 300/1.5-0.5 1.5 3.0 5501100600 23MST 300/2-0.5 2.0 4.0 5501105900 23MST 300/3-0.5 3.0 6.0 5501110

1200 23MST 300/4-0.5 4.0 8.0 55011151500 23MST 300/5-0.5 5.0 10.0 55011201800 23MST 300/6-0.5 6.0 12.0 55011252100 23MST 300/7-0.5 7.0 14.0 55011302400 23MST 300/8-0.5 8.0 16.0 55011322700 23MST 300/9-0.5 9.0 18.0 55011353000 23MST 300/10-0.5 10.0 20.0 55011403600 23MST 300/12-0.5 12.0 24.0 55011454500 23MST 300/15-0.5 15.0 30.0 55011506000 23MST 300/20-0.5 20.0 40.0 5501155

MST mats, 400 V, width 0.5 mOUTPUT

[W]Type MST300 W/m2

AREA [m2]

LENGTH [m] Cat. No.

900 40MST 300/3-0.5 3.0 6.0 55013001200 40MST 300/4-0.5 4.0 8.0 55013051800 40MST 300/6-0.5 6.0 12.0 55013102100 40MST 300/7-0.5 7.0 14.0 55013152700 40MST 300/9-0.5 9.0 18.0 55013203600 40MST 300/12-0.5 12.0 24.0 55013254200 40MST 300/14-0.5 14.0 28.0 55013304800 40MST 300/16-0.5 16.0 32.0 55013355400 40MST 300/18-0.5 18.0 36.0 55013406600 40MST 300/22-0.5 22.0 44.0 5501345

30 W/m for removing ice and snow from roofs and gutters. A control system with an air temperature and moisture sensor must be used

to prevent cables from switching on in temperatures of more than +5 °C.

TYPE Suitability Max. loadingFloor heating in living areas Yes 30 W/mOutdoor surface heating Yes 30 W/mFrost protection of pipes Yes 15 W/mPipe heating Yes 15 W/mRemoving ice and snow from roofs and gutters Yes 30 W/m

PAVEMENT1 hardened surface, e.g. fl oor tiling2 humidity sensor (water, snow, ice)3 sand fi ll and the sub-base of the cable4 ECoFLooR® MAPsV/MADPsP heating cable or MsT/MDT mat5 fi rm gravel base (macadam)

DRIVEWAY1 hardened surface, e.g. interlocking pavement2 humidity sensor (water, snow, ice)3 sand bed of the interlocking pavement4 concrete board (protects the heating cable from vehicle load)5 ECoFLooR® MAPsV/MADPsP heating cable or MsT/MDT mat6 fi rm gravel base (macadam)

22

PFP – automatic heating cable with a thermostat, electrical socket connection, the thermostat switches on at +3 °C, 1.5 m con-nection cable with plug, IP 66 coverage.

The MDT heating mat is provided with a 1×5 m cold lead

Cables and mats are packed in PE foil.

MADPSP cable, 400 V

OUTPUT [W]

MADPSP 30 W/m

400 V

LENGTH [m] Cat. No.

520 30520 17.1 2323453

860 30860 29.1 2323456

1330 301330 44.6 2323459

1550 301550 51.6 2323462

2000 302000 66.7 2323465

2600 302600 85.5 2323468

2800 302800 93.4 2323471

3600 303600 119.8 2323474

4500 304500 134.9 2323475

5100 305100 166.7 2323477

7700 307700 259.7 2323480

OUTPUT [W]

MADPSP 20 W/m

400 V

LENGTH [m] Cat. No.

420 20420 21.2 2323403

700 20700 35.7 2323406

1100 201100 53.9 2323409

1250 201250 64.0 2323412

1600 201600 83.3 2323415

2100 202100 105.8 2323418

2300 202300 113.7 2323421

3000 203000 143.5 2323424

3600 203600 168.7 2323425

4200 204200 202.2 2323427

6300 206300 317.5 2323430

MDT mat, 230 V, width 0.5 m MDT mat, 400 V, width 0.5 m

OUTPUT [W]

MDT 300 W/m2

AREA [m2]

LENGTH [m] Cat. No.

270 23MDT300/0.9–0.5 0.9 1.8 5500100

450 23MDT300/1.5–0.5 1.5 3.0 5500105

700 23MDT300/2.3–0.5 2.3 4.6 5500110

800 23MDT300/2.7–0.5 2.7 5.4 5500115

1050 23MDT300/3.5–0.5 3.5 7.0 5500120

1350 23MDT300/4.5–0.5 4.5 9.0 5500125

1480 23MDT300/5–0.5 5.0 10.0 5500130

1900 23MDT300/6.3–0.5 6.3 12.6 5500135

2300 23MDT300/7.8–0.5 7.8 15.6 5500140

4000 23MDT300/13.3–0.5 13.3 26.6 5500145

OUTPUT [W]

MDT 300 W/m2

AREA [m2]

LENGTH [m] Cat. No.

520 40MDT300/1.8–0.5 1.8 3.6 5500200

860 40MDT300/2.9–0.5 2.9 5.8 5500205

1330 40MDT300/4.5–0.5 4.5 9.0 5500210

1550 40MDT300/5.2–0.5 5.2 10.4 5500215

2000 40MDT300/6.7–0.5 6.7 13.4 5500220

2600 40MDT300/8.7–0.5 8.7 17.4 5500225

2800 40MDT300/9.3–0.5 9.3 18.6 5500230

3600 40MDT300/12–0.5 12.0 24.0 5500235

4500 40MDT300/15–0.5 15.0 30.0 5500240

7700 40MDT300/25.7–0.5 25.7 51.4 5500245

30 W/m (35 W/m) for removing ice and snow from roofs and gutters. A control system with an air temperature and moisture sensor must be used

to prevent cables from switching on in temperatures of more than +5 °C.

MADPSP heating cable, a two-conductor cable with a full protec-tion screen and protection against UV radiation. Suitable for heating outdoor surfaces. Class M2. Cold lead 1×5 m. Ø 6.2–8.9 mm.

TYPE(Ohm/m) Cat. No.

18.00 20007006.40 20007052.70 20007102.00 20007151.20 20007200.72 20007250.60 20007300.36 20007350.25 20007370.18 20007400.08 20007450.04 2000750

OUTPUT [W]

MADPSP 20 W/m

LENGTH [m] Cat. No.

240 20240 12.2 2323203400 20400 20.7 2323206630 20630 31.1 2323209730 20730 36.2 2323212950 20950 46.4 2323215

1200 201200 61.2 23232181300 201300 66.5 23232211700 201700 83.7 23232242000 202000 100.2 23232252400 202400 117.0 23232273600 203600 183.7 23232305100 205100 227.6 2323233

OUTPUT [W]

MADPSP 15 W/m

LENGTH [m] Cat. No.

210 15210 14.0 2323153350 15350 23.6 2323156540 15540 36.3 2323159630 15630 42.0 2323162810 15810 54.4 2323165

1050 151050 70.0 23231681150 151150 75.2 23231711500 151500 95.0 23231741800 151800 111.3 23231752100 152100 133.7 23231773150 153150 209.9 23231804500 154500 255.7 2323183

OUTPUT [W]

MADPSP 25 W/m

LENGTH [m] Cat. No.

270 25270 10.9 2323253450 25450 18.4 2323256700 25700 28.0 2323259800 25800 33.1 2323262

1050 251050 42.0 23232651350 251350 54.4 23232681480 251480 58.5 23232711900 251900 74.8 23232742300 252300 87.2 23232752700 252700 103.9 23232774000 254000 165.3 23232805700 255700 203.5 2323283

OUTPUT [W]

MADPSP 30 W/m

LENGTH [m] Cat. No.

300 30300 9.8 2323303500 30500 16.5 2323306760 30760 25.8 2323309880 30880 30.1 23233121150 301150 38.3 23233151500 301500 49.0 23233181600 301600 54.1 23233212100 302100 67.8 23233242500 302500 80.5 23233253000 303000 93.5 23233274400 304400 150.3 23233306300 306300 183.7 2323333

Cables on dr. Heating circuits 230 V

TYPE Suitability Max. loadingFloor heating in living areas Yes 20 W/mOutdoor surface heating Yes 30 W/mFrost protection of pipes Yes 15 W/mPipe heating Yes 15 W/mRemoving ice and snow from roofs and gutters Yes 35 W/m

FOOTBALL PITCH1 grass2 soil layer, approx. 30 cm thick3 sand bedding, approx. 7 cm (compacted) and approx. 3 cm thick fi ll4 ECoFLooR® MAPsV/MADPsP heating cable or MsT/MDT mat

(approx. 20 W/m, 100 W/m2, cable loop spacing 20 cm)5 Levelled solid base (existing soil)

OUTPUT [W] Type PFP LENGTH

[m] Cat. No.

12 PFP 1m/12W 1 233015025 PFP 2m/25W 2 233015236 PFP 3m/36W 3 233015448 PFP 4m/48W 4 233015672 PFP 6m/72W 6 2330158

136 PFP 10m/136W 10 2330160152 PFP 14m/152W 14 2330162281 PFP 21m/281W 21 2330164337 PFP 30m/337W 30 2330166490 PFP 42m/490W 42 2330168

23

STAIRS1 wear layer (fl oor tiling)2 fl exible bonding cement3 ECoFLooR® ADPsV/MAPsV/

MADPsP/PDsP heating cable4 stairs

ADSV+ heating cable, a two-conductor cable with a full protection screen. The sheathing of the cable is resistant against UV radiation and is intended for fl oor heating and the removal of snow and ice from roofs and eaves troughs. 1×3 m cold lead. Ø 5.0 mm.

TYPE Suitability Max. loadingFloor heating in living areas Yes 20 W/mOutdoor surface heating No –Frost protection of pipes Yes 10 W/mPipe heating Yes 10 W/mRemoving ice and snow from roofs and gutters Yes 20 W/m

OUTPUT [W]

Type ADSV+18 W/m

LENGTH [m] Cat. No.

160 18160 8.5 2253100260 18260 14.5 2253105320 18320 18.5 2253110420 18420 24.0 2253115520 18520 28.4 2253120600 18600 34.4 2253125680 18680 37.9 2253130830 18830 46.1 2253135

1000 181000 57.5 22531401200 181200 68.9 22531451500 181500 83.2 22531501700 181700 100.4 22531552200 182200 122.7 22531602600 182600 149.6 2253165

OUTPUT [W]

Type ADSV+20 W/m

LENGTH [m] Cat. No.

160 20160 8.3 2253200270 20270 14.0 2253205340 20340 17.2 2253210450 20450 22.5 2253215540 20540 27.4 2253220640 20640 32.1 2253225720 20720 35.8 2253230870 20870 43.8 2253235

1070 201070 53.5 22532401290 201290 64.4 22532451580 201580 79.0 22532501850 201850 92.4 22532552300 202300 117.3 22532602750 202750 141.4 2253265

OUTPUT [W]

Type ADSV+ 10 W/m

LENGTH [m] Cat. No.

120 10120 11.4 2253000200 10200 18.9 2253005250 10250 23.6 2253010320 10320 31.6 2253015400 10400 36.9 2253020450 10450 45.9 2253025520 10520 49.6 2253030600 10600 63.9 2253035750 10750 75.8 2253040950 10950 87.0 22530451100 101100 114.5 22530501300 101300 131.3 22530551700 101700 158.5 22530602000 102000 194.5 2253065

Heating circuits

ADPSV heating cable, a twin conductor, full protection screened cable with protection against UV radiation. This multipurpose cable is suitable for indoor and outdoor applications. Class M2. Cold lead 1×5 m. Ø 5.0–5.9 mm.

TYPE Suitability Max. loadingOutdoor surface heating Yes 20 W/mFrost protection of pipes Yes 10 W/mPipe heating Yes 10 W/mRemoving ice and snow from roofs and gutters Yes 20 W/m

OUTPUT [W]

Type ADPSV10 W/m

LENGTH [m] Cat. No.

120 10120 11.4 2256010200 10200 18.9 2256015250 10250 23.6 2256020320 10320 31.6 2256025400 10400 36.9 2256030450 10450 45.9 2256035550 10550 56.1 2256040600 10600 63.9 2256045750 10750 75.8 2256050950 10950 87.0 22560551100 101100 114.5 22560601300 101300 131.3 22560651700 101700 158.5 22560702000 102000 194.5 2256075

OUTPUT [W]

Type ADPSV

20 W/mLENGTH

[m] Cat. No.

160 20160 8.3 2252800270 20270 14.0 2252805340 20340 17.2 2252810450 20450 22.5 2252815540 20540 27.4 2252820640 20640 32.1 2252825780 20780 39.3 2252830870 20870 43.8 2252835

1070 201070 53.5 22528401290 201290 64.4 22528451580 201580 79.0 22528501850 201850 92.4 22528552300 202300 117.3 22528652750 202750 141.4 2252870

TYPE(Ohm/m) Cat. No.

38.72 200050014.02 20005058.96 2000510

5.232 20005153.58 2000520

2.568 20005251.714 20005351.382 20005400.926 20005500.638 20005550.424 20005600.31 2000565

0.196 20005700.136 2000575

Cables on drums Heating circuits

ADPsV cable.Packed on a cardboard reel.

PDSP heating cable, a two-conductor cable with a full protection screen and protection against UV radiation. Suitable for heating outdoor surfaces. Class M2. Cold lead 1×5 m. Outer cable diameter – oval 4.5×7 mm.

TYPE Suitability Max. loadingFloor heating in living areas Yes 28 W/mOutdoor surface heating Yes 28 W/mRemoving ice and snow from roofs and gutters Yes 28 W/m

A control system with an air temperature and moisture sensor must be used to prevent cables from switching on in temperatures of more than +5 °C.

(Ohm/m) OUTPUT [W]

PDSP 28 W/m

LENGTH [m] Cat. No.

3.58 640 15210 23.1 23238102.05 890 15350 29 23238150.93 1270 15540 44.8 23238200.42 1900 15630 66.3 23238250.196 2700 15810 100 23238300.136 3400 151050 114.4 2323835

Heating circuits

24

SPECIAL APPLICATIONS

OUTPUT [W]

Type PDS1P40 W/m

LENGTH [m] Cat. No.

130 40130 3.3 2325000380 40380 10.0 2325005760 40760 19.0 2325010

1400 401400 35.0 23250181500 401500 38.0 23250203300 403300 82.0 2325030

CONCRETE CURING CABLE CIRCUITSA twin conductor screened cable with a 1×2 m cold lead with plug connection. 230 V.

PDS1P cable for curing concrete. Packed in PE foil.

PCC circuits are made from braided (armoured) cable with a constant linear wattage of 30 W/m – with a connecting lead (termed a cold lead) with a length of 1.5 m. Thanks to the silicon jacket and the thermal resistance, they are ideal for the pro-tection of insulation for refrigeration equipment and freezers.

PC / PC-S CABLES WITH CONSTANT LINEAR WATTAGE; PCC CIRCUITSCables provide a constant wattage per standard metre which enables their shortening and fi nal alterations at the place of installation. Applica-tions – the heating of insulation in freezers, pipe heating, process heating, heating of compressor drainage pipes, etc.

The cable consists of two independently insulated supply conductors around which a very thin heating (resistance) wire is wound. It is connected to the supply conductors every 1 m of length – alternately to the phase and to the working conductor. In this way, ‘heating zones’ with a length of 1 m are created. To simplify – these are one-metre long resistance cables connected one after another in a coil. The whole structure is fi tted with a PC-S type silicon jacket, and also with a braided protective screen – termed armouring. The cable can be shortened to the required length; the wattage per 1 m remains the same, however. WARNING: the beginning and end of the cable will not give out heat; heating occurs from the fol-

lowing (preceding) heating zone! In an extreme situation, if the cable is shortened immediately after the connection of the resistance wire to the conduc-tor, this non-heating part can be up to 1 m long – we therefore recommend that a minimum of 1 m of extra cable is ordered.

Marking Protective braiding(armouring)

Output [W/m]

Operating temperatures

Temperature resistance

Length of heating zone

Min. order length

Max. length of circuit Cat. No.

PC 25 – 25 −50…60 °C 180 °C 1) 1 m 2 m 80 m 2330210PC 50 –

50 −50…60 °C 180 °C 1) 1 m 2 m 70 m2330214

PC-S 50 CuSn (1 mm²) 2330216

Operating voltage 230 V / 50 Hz, dielectric strength 1 500 V, cross sectional area of the conductors 2×0.75 mm² (for 25 W/m) and 2×1.5 mm² (for 50 W/m), heating (resist-ance) conductor Ni/Cr (80/20).

Type Output [W]

Linear wattage

Operating temperatures

Temperatureresistance

Length [m]

Resistance [] Cat. No.

PCC 90/3 90

30 W/m −40…60 °C 180 °C 1)

3.0 587.8 2330250PCC 150/5 150 5.0 352.7 2330252PCC 210/7 210 7.0 251.9 2330254PCC 300/10 300 10.0 176.3 2330256

Operating voltage 230 V / 50 Hz, IP 67 coverage, cable diameter 4–4.4 mm; 1×cold lead 1.5 m

1) Thermal resistance of the cable in a switched-off state

THE D-MAT HEATING SHEETIntended for outdoor use as anti-freeze protection in industrial applications and in the construction industry – for example, for the warming of the earth in excavation pits or of stored friable materials, the warming of cables on reels, main-tenance of warmth in parts of machines or in tools, etc. The sheet is also suitable for use in extreme winter conditions. Technical parameters: IP 56 ra t ing ; hea ted area 1.2×2.85 m (3.4 m2); total sheet dimensions 1.5×3.05 m; 5 m supply lead ends in a SCHUKO plug. 230 V / 50 Hz; 9.6 kg.

OUTPUT [W]

Type D-MAT280 W/m2 Cat. No.

950 DM 3.4/280 5505000

Marking Output W/m 10°C

Temperature tolerance [°C]

Limitation for installation Max. length at the temperature setting Cat. No.

Min. temp. Min. radiusELSR-M – Frost protection of pipe 6 A 10 A 16 AELSR-M – 10 BO 10 65 –30°C 35 mm 65 m 95 m 105 m 2330310ELSR-M – 15 BO 15 65 –30°C 35 mm 37 m 58 m 65 m 2330315ELSR-N – Frost protection of trays, gutters, roofs, technological heating 16 A 20 A 25 AELSR-N – 20 BO 20 80 –10°C 20 mm 94 m 116 m 146 m 2330320ELSR-N – 30 BO 30 80 –10°C 20 mm 70 m 87 m 109 m 2330330KIT Nr. 4 For connection and termination of self-limiting cables 5030124Cold lead for self-regulating cablesSK 1.5 Limitation: 12 A / 20 m 2000790SK 2.5 Limitation: 20 A / 20 m 2000795

SELF-REGULATING CABLES

Industrial applications: Analyzer lines – prevent condensation Cooling water lines – anti-freeze protection Potable water lines – anti-freeze protection

Caustic soda – prevents crystallization under 30 °C Oils and fats – maintain pumpable viscosity Heating oil – prevents wax dispersion Vessel – anti-freeze and condensation protection

ELSR self-regulating cables are parallel electrical heating strips constructed from a specially fi n-ished plastic with embedded carbon particles that create an electrical path between two parallel copper bus bars.

SNOW MAT

Heated rubber mat for entry cleaning zones; 155×100×0.8 cm (460 W), 5 m supply lead with plug, mat IP: 65, plug IP: 54.

NEW

OUTPUT [W]

Type SNOW MAT Cat. No.

460 SM 1.5/460 5504505

25

ECOFLOOR ACCESSORIES

F-BOARD FLOOR INSULATIONF-boards prevent heat losses to the subfl oor structure. Recommended for fl oor reconstructions.

Type Dimensions [mm] Thickness [mm]

Packaging Packets on the pallet Cat. No.

[boards in packet] [m2]F-BOARD 6 1200×600×6 6 6 4.32 70 5442016F-BOARD10 1200×600×10 10 6 4.32 50 5442019

Useful information

Dimensions 600 mm × 1200 mm (0.72 m2 each)

Thickness 6 mm or 10 mm

Weight (kg/board) 2.35 (6 mm) 2.37 (10 mm)

Material Extruded Polystyrene core with Polymer cement outer skin

Density 35 kg/m3

Thermal Conductivity 0.029 W/m°k

Compresive strenght 300 kPa

Water absorption (immersion) < 1.5 % by vol

Water absorption (capillary) NilCo-effi cient of Linear Expansion 0.07 mm/mKFlammability B1

Floor Tiles

Tile Adhesive

Tile Adhesive

ECOFLOOR Mat

F-BOARD

Sub-Floor – or Existing Floor (before renovation)

Quantity supplied Cat. No.

Gutter clip 100; Intended for standard 100 mm semicircular gutters – install approx. 4 pcs/1 m (spacing 25 cm). 1 package = 25 pcs 1 package 2350000

Downpipe cable clip; For the attachment of a cable on a chain in the downspout – install approx. 4 pcs/1 m (spacing 25 cm). 1 package = 25 pcs 1 package 2350003

Chain, 1 package = 10 m. Material: frost-resistant plastic. 1 package 2350004

Grufast – spacing of grips: 3.5 cm. Universal fi xing tape for the fi xation of heating cables. Consumption: approx. 1 pc/ 4 m2. 1 unit = 10 m, NOT suitable for outdoor enviroments 1 unit 4200013

Cable Fix AL 25 – universal fi xation strip for heating cables, suitable also for outdoor use – e .g. for roof gutters – thanks to the materials used (aluminium). DIMENSIONS: thickness 0.5 mm; width 21 mm; length 10 m; axial spacing of the grips 25 mm

1 unit 4200016

Plastic cable clip, 1 package = 50 pcs 1 package 1200000

T-strip; material: plastic; strip length 0.5 m; fi xation of heating cables with a diameter of 3.5–9 mm.Axial distance of grips 1 cm, total strip height 10 mm, option of connecting the strips.

1 package = 20 pcs 2350009

REPAIR KIT

Kit no. 1 – for PV cable repair 1 5030121

Kit no. 2 – for ADSV, ASL1P, PSV, CM Mat LD and LDTS cable repair 1 5030122

Kit no. 3 – for MADPSP, MAPSV, MST, MDT and ADPSV cable and mat repair 1 5030123

Kit no. 4 – for connection and termination of self-limiting cables 1 5030124

Kit no. 5 – for MADPSP installed under asphalt 1 5030125

Kit no. 6 – termination of PC/PC-S cables with linear wattage 1 5030126

OTHER ACCESSORIES

Self-adhesive aluminium tape – width 50 mm, length 50 m.Designed for the fi xation of heating cables to pipes (temperature resistance 150 °C). 1 2832515

SYFOK-B; material: stainless steel cord and frost-resistant plastic.B/20 (20 m) 2350010B/10 (10 m) 2350011

SYFOK-P – fi xation cables for nonstandard eaves, gutters and valleys. Material: frost-resistant plastic.

P/20 (20 m) 2350012P/10 (10 m) 2350013

Spacing grip; material: frost-resistant plastic, package contains 25 pcs. Maintains the spacing (approx 4.5 cm) of cables running in parallel. 1 package 2350014

C-shaped copper roof spacer, 1 package = 25 pcs 1 package 2350005

26

heating fi lmECOFILM®

Ecofi lm heating fi lms use state of the art technology and are primarily used for heating large surfaces. These heating systems are composed of laminated polyester fi lms with a graphite coat-ing, supply leads, and accessories. We offer ECOFILM fi lms in 3 versions: underfl oor heating fi lms (“F”), ceiling fi lms (“C”) and mirror heating fi lms.

The F fi lm is installed directly beneath a fl oating fl oor. Due to its ultra thin profi le (max 0.4 mm thick) the original construction height of the fl oating fl oor is hardly affected. This silent, unobtrusive and dry-laid underfoot heating system is highly reliable and has a long life span. We provide a 10-year warranty for ECOFILM heating fi lms; however, their operational life can be longer (30–50 years). The product has been tested according to European standards.

ECOFILM setThe do-it-yourself kit for underfl oor heating may be installed easily and quickly by following the relevant instructions. No professional installation company required. The fi nal electrical connection must be carried out by a qualifi ed electrician. As the Ecofi lm set comes complete for installation, no accessories are needed. We recom-mend 60 W/m2 for a fl oating wooden fl oor and 80 W/m2 for a fl oating laminated fl oor.

TYPEWIDTH [mm] Output

(W/m2)LENGTH

[m]

Total Output

[W]Cat. No.

TOTAL ACTIVE

Eset 60-1.5/50

600 550 60 W/m2

(230 V)

1.5 50 6652495Eset 60-2/66 2 66 6652500Eset 60-2.5/83 2.5 83 6652503Eset 60-3/99 3 99 6652505Eset 60-4/132 4 132 6652510Eset 60-5/165 5 165 6652515Eset 60-6/198 6 198 6652520Eset 60-8/264 8 264 6652525Eset 60-10/330 10 330 6652530Eset 80-1.5/66

600 550 80 W/m2

(230 V)

1.5 66 6652538Eset 80-2/88 2 88 6652540Eset 80-2.5/110 2.5 110 6652543Eset 80-3/132 3 132 6652545Eset 80-4/176 4 176 6652550Eset 80-5/220 5 220 6652555Eset 80-6/264 6 264 6652560Eset 80-8/352 8 352 6652565Eset 80-10/440 10 440 6652570Eset 80-1.5/117

1000 970 80 W/m2

(230 V)

1.5 117 6652708Eset 80-2/156 2 156 6652710Eset 80-2.5/195 2.5 195 6652713Eset 80-3/234 3 234 6652715Eset 80-4/312 4 312 6652720Eset 80-5/390 5 390 6652725Eset 80-6/468 6 468 6652730Eset 80-8/624 8 624 6652735Eset 80-10/780 10 780 6652740

The Ecofi lm set includes: Ecofi lm F608/55 (F606/55, 1008) electrical heating fi lm delivered in rolls of various lengths according to the customer’s requirements and layout plan. The heating fi lm is supplied with insulated cut edges and cold leads. An additional pair of insulation discs for insulating the copper electrodes of the heating fi lm in the event that there is a requirement to shorten the length of the heating fi lm. Installation manual.

The fi lm is fi tted with two SK AV1.5 cold leads 3 mm in diameter and 5 m long.

WAGOWAGO

Simplifi ed Example of ECOFILM SetDesign total surface area 4.3×3.1 m. Heating under laminated fl oor. Recommended application: ECOFILM Set 80 W/m2.Note: Heating parts of the fi lm must not overlap and their minimal dis-tance from fi xtures and wall shall be 5 cm.Owing to the previous note, three 1000 mm-wide fi lm strips of 3 m and 2 m in length and two 600 mm-wide fi lm strips of 3 m and 2 m in length may be used. For the given application the use of the following is recommended: 2×Eset 80-3/234, 1×Eset 80-3/132, 1×Eset 80-2/156 and 1×Eset 80-2/88 + temperature control.

27

*) delivered as a roll; accessories required for installation must be ordered separately**) while stocks last

Gentle and safe heating for your comfortHeating fi lm makes an ideal fl oor heating system for laminated or wooden fl oating fl oors. The technical parameters of the heating fi lm ensure that the materials’ temperature resistance values are observed. Health and safety standards are also maintained as the maximum fl oor surface temperature is thermostatically limited to 27 °C. Traditional heaters, which utilise a liquid to transfer the heat, operate at (for example) signifi cantly higher temperatures and result in a greater fl uctuation in air humidity, and undesirable effects on wooden and laminated fl oors. It is hardly surprising that this sophisticated system has been used to safely and comfortably heat in excess of 2.5 million m2 of fl oors throughout Europe and has been warmly endorsed by such leading fl oor manufacturers as PERGO, SCANDIFLOOR, ALLOC, KÄHRS and JUNCKERS.

ECOFILM F – underfl oor heating fi lm

Flexible Ecofi lm heating fi lm is the ideal solution for economical electric underfl oor heating for laminated and wooden fl oating fl oors. The product is ultrathin, yet robust, and is a dry-laid system that is easy to install.

Easy, precise and fast installationThe heating fi lm is produced in rolls 600 mm wide (550 mm heating surface, two 25 mm non-heating edges) and 1 000 mm wide (970 mm heating surface, two 15 mm non-heating edges). Thanks to its special material composition, the heating fi lm may be cut every 10 mm to obtain exactly the required length of strips. The strips are laid side-by-side across the entire heating surface and are interconnected in parallel using cables with connectors. ECOFILM F heating components must neither overlap nor cross one another. This method of laying the fi lm saves time and especially reduces labor costs. Installers will appreciate that the fl oating or wooden fl oor may be laid immediately after the heating fi lm is installed and connected.

ECOFILM F with accessories

Sectional view of laminated (wooden) fl oor (reconstruction)

1 three-layer wooden or laminate fl oating fl oor2 fl oor (limitation) probe in a groove3 PE foil covering, 0.25 mm thick4 ECoFILM® fl oor heating foil5 insulation underlay from extruded polystyrene6 base – concrete, anhydrite, original fl oor etc.

TYPE *WIDTH [mm]

Output [W/m2] Output [W/m] Voltage Cat. No.TOTAL ACTIVE

Laminate, wood or real timber fl oorECOFILM F 48V ** 530 500 80 40 48 V 6652010ECOFILM F 608/55 600 550 80 44

230 V

6652302ECOFILM F 606/55 600 550 60 33 6652301ECOFILM F 604/55 600 550 40 22 6652300ECOFILM F 1008 1000 970 80 78 6652310ECOFILM F 1006 1000 970 60 58 6652309ECOFILM F 1004 1000 970 40 22 6652308

Illustrative photos—installation of ECOFILM F608 under fl oating fl oor

ECOFILM F connection in parallel with Mastic

ideal temperature characteristic under-fl oor heating temperature characteristic

28

ECOFILM C heating fi lms provide an ideal ceiling heating system with balanced heat distribution throughout the room (without temperature gradients). Control of the ECOFILM C’S temperature is achieved by the use of an electronic thermostat which controls the room temperature. As it is a radiant heating system, the same comfort level as achieved by convection heating may be obtained at lower temperatures. Generally, reducing the temperature by 1 °C lowers total heating costs by 6 %.

ECOFILM C – ceiling heating fi lm

Sectional view of ceiling structure

1 load-bearing ceiling structure; 2 thermal insulation; 3 CD load-bearing sections of the plasterboard structure; 4 ECoFILM® ceiling heating foil5 PE foil covering, 0.25 mm thick; 6 plasterboard ceiling (fl oating)

ECOFILM C with connected cold lead

Installation of connector cover

Illustrative photos of ECOFILM C installation on metal joists

Installation: Crimp connector and cold lead

*) delivered as a roll; accessories required for installation must be ordered separately

ideal temperature characteristic ceiling radiant heating temperature characteristic

TYPE *WIDTH [mm]

Output [W/m2] Output [W/m] Cat. No.TOTAL ACTIVE

ECOFILM C 420 400 300 200 60 6652102ECOFILM C 414 400 300 140 42 6652202ECOFILM C 520 500 400 200 80 6652210ECOFILM C 514 500 400 140 56 6652220ECOFILM C 510 500 400 100 40 6652225

29

MIRROR HEATING FILM – perfectly prevents mirror foggingSafe operation. The Ecofi lm MHF fi lm operates at low temperatures and prevents overheating or damage to the mirror. Installation is simple and fast. The MHF fi lm has an adhesive layer (with release backing) that easily sticks to the rear of a mirror. The mirror heater can be wired into the electric circuit of a lighting fi xture so that it is activated whenever the light is switched on. Due to its low input, the heating fi lm's operating costs are negligible. ECOFILM MHF heating fi lm requires no maintenance.

Product Description Amount supplied Cat. No.

Crimp connector for Ecofi lm C and F 1 unit 6651001

Crimp cover for Ecofi lm C 1 unit 6651002

brownblue

Cold lead 1.5 for Ecofi lm C 1 m 665100xCold lead AV 1.5 for Ecofi lm F 1 m 66510x0Cold lead AV 2.5 for Ecofi lm F 1 m 66510x0

Crimp tool 1 unit 6651003

Insulating tape for sealing cut edges of heating fi lm28 mm width/33 m length38 mm width/33 m length

1 roll

6651026

6651028

MASTIC VM connector insulation for Ecofi lm F 38 mm width (1 connector requires 0.1 m) 1m 6651012

WAGO connector (terminal strip) for Ecofi lm set 1 unit 6651007

WITH MHF WITHOUT MHF

TYPE Output [W] Dimensions [mm] Cat. No.MHF 12 12.5 274×252 6651850MHF 25 25 274×574 6651860MHF 50 50 524×519 6651870MHF 100 100 524×1004 6651880

1 m cold lead, IP 44, class II

HEAT-PAK for the placement of ECOFILM F, ECOFILM SET heating foil under a carpet or PVCThis underlay with good thermal conductivity enables the installation of fl oor heating directly under a carpet or PVC when it isn’t possible to place the heating cable into screed (for example, in the case of additional installation or reconstruction work). Completely dry installation; raises the fl oor by only 10 mm. The packaging contains 8 boards (4×3 mm thick base boards and 4×4 mm thick covering boards); each of them is coated in a thin layer of adhesive. Laid in two layers, the boards are glued to each other (staggering of joints is necessary – in this way, the joints don’t show through on the fl oor covering). A rigid, 7 mm thick compact construction is created onto which PVC or carpet can be laid (freely or glued). Sold only as whole packages.1 wear layer (PVC, carpet); 2 HEAT-PAK 7 mm two-layer glued underlay; 3 fl oor (limitation) probe in the groove (embedded); 4 PE foil covering, 0.25 mm thick; 5 ECoFILM® fl oor heating foil; 6 insulation underlay from extruded polystyrene; 7 base – original fl oor, concrete anhydrite, etc.

Type Thickness [mm]

Capacity [kg/m3]

Conductivity [W/mK] Strength in fl exure Dimensions of the boards

[m]Package

[m2] Cat. No.

HEAT-PAK 7 3 and 4 770 0.07 > 40 kg / cm2 boards 0.6×1.2 2.88 m2 5442024

FLOOR INSULATION under wood/laminate fl oor with ECOFILM F, ECOFILM SET heating foil1 three-layer wooden or laminate fl oating fl oor; 2 fl oor (limitation) probe in a groove; 3 PE foil covering, 0.25 mm thick; 4 ECoFILM® fl oor heating foil; 5 insulation underlay from extruded polystyrene; 6 base – concrete, anhydrite, original fl oor etc.

Type Thickness [mm]

Bulk density [kg/m2]

Thermal conductivity coeffi cient [W/mK]

Load resistance[t/m2]

Dimensions of insulation [m]

Package [m2] Cat. No.

STARLON 3 3 40 0.0315 5.2 0.5×1.0 boards 5.0 5442032

STARLON 6 6 33 0.0298 6.7 0.5x1.0 boards 5.0 5442034

ECOFILM MHF – mirror fogging prevention

ECOFILM ACCESSORIES

30

ULTRATHERM heating for vivariums and terrariums

Viv Strip – heating strips – due to their size, Viv Strip heating strips are suitable mainly for the warming of selected areas within a vivarium or terrarium housing specifi c types of reptile. Cold lead 2 m. IPX4, class II.

TYPE Output [W] Voltage [V] Dimensions [mm] Cat. No.

Ultratherm Viv Strip 11 11

230 V / 50 Hz

150×410 8510051

Ultratherm Viv Strip 15 15 150×572 8510053

Ultratherm Viv Strip 23 23 150×868 8510055

Ultratherm Viv Strip 32 32 150×1188 8510057

Happy Hamster – heating foil – due to its dimensions this heating foil is suitable for breeders of various types of rodent. Although rodents are not primarily heat-loving animals, in the winter season they enter a certain form of winter hibernation and Happy Hamster heating foil is ideal to help them get through this period in comfort. Cold lead 2 m. IPX4, class II.

TYPE Output [W] Voltage [V] Dimensions [mm] Cat. No.

Ultratherm Happy Hamster 8 230 V / 50 Hz 178×280 8510071

Viv Mat – heating foils – Viv Mat heating foils are larger than Viv Strip strips and so are used when it is necessary to heat the majority of the area of a vivarium or terrarium. Cold lead 2 m. IPX4, class II.

TYPE Output [W] Voltage [V] Dimensions [mm] Cat. No.

Ultratherm Viv Mat 7 7

230 V / 50 Hz

274×142 8510001

Ultratherm Viv Mat 15 15 274×276 8510003

Ultratherm Viv Mat 22 22 274×410 8510005

Ultratherm Viv Mat 30 30 274×572 8510007

Ultratherm Viv Mat 39 39 274×732 8510009

Ultratherm Viv Mat 46 46 274×868 8510011

Ultratherm Viv Mat 64 64 274×1188 8510013

ULTRATHERM HEATING FILMS AND STRIPS

In 2008 Aztec Europe Ltd. joined FENIX Holding. Aztec Europe Ltd. is based in Great Britain and focuses on the production of special purpose heating elements using mainly ECOFILM foil. These products include heating systems for vivariums and terrariums.

31

ULTRATHERM RADIANT PANELS

ULTRATHERM REGULATION

ULTRATHERM – radiant heating panels – these panels utilise the principle of infrared radiation and are primarily intended for the localised heating and warming of breeding places, large terrariums or dog kennels. They are equipped with a thermal fuse which protects the panel from overheating. It is possible to install them in a vertical position; for horizontal installation it is necessary to order mounting frames. The standard colour is brown; white versions can be ordered and other colours are possible for an additional fee.

Ultratherm Terra-Heat – this thermostat is designed for the check-ing of air or soil temperature in a terrarium or vivarium. It is very simple to use and can be connected to any Ultratherm heating foil or heat strip, heating cable or mat, and also to other heaters available on the market with a maximum output of up to 3 600 W.

TYPE [W] [V] Coverage Dimensions [mm] Weight [kg] Quantity on pallet Cat. No.

Panel ULTRATHERM 100 h 100

230 IP 44

500×320×30 2.5Recommended height of

installationThe apertures used for

hanging the ULTRATHERM panel are on the rear side of the panel. For the installation

of a panel in a horizontal position it is necessary to

order a ceiling frame.

60 8515010

Panel ULTRATHERM 200 h 200 750×320×30 3.7 45 8515015

Panel ULTRATHERM 270 h 270 1000×320×30 5.2 30 8515020

Panel ULTRATHERM 330 h 330 1250×320×30 6.6 30 8515025

Panel ULTRATHERM 400 h 400 1500×320×30 7.9 30 8515030

Ceiling fi xing frame for the horizontal installation of ULTRATHERM 100 panels 5401230

Ceiling fi xing frame for the horizontal installation of ULTRATHERM 200–270 panels 5401231

Ceiling fi xing frame for the horizontal installation of ULTRATHERM 330–400 panels 5401232

CERAMIC HEATING BULBS

Ceramic heating bulbs – heating bulbs (lamps) function on the principle of infra-red radiation – they imitate the sun’s heat radiation and thus create conditions close to those in the natural environment. Heating lamps have a standard screw base which fi ts normal plastic bulb holders; however, due to the higher operating temperatures involved, we defi nitely recommend using ceramic bulb holders. The range, intensity and direction of the heat current can be increased using an aluminium refl ector. Heating bulbs can be used to create different temperature zones within a terrarium.

TYPE Output [W] Voltage [V] Cat. No.

100 W ceramic heating bulb 100

230 V / 50 Hz

8530001

150 W ceramic heating bulb 150 8530002

250 W ceramic heating bulb 250 8530003

Ceramic bulb holder for the heating bulb 8530010

AL refl ector for the heating bulb 8530015

250 W ceramic heating bulb

Description Cat. No.

Settable temperature range 5–49 °C; measured temperature range 5–49 °C; accuracy: ±1 °C; input wattage 230 V, 50 Hz. Sensor 2 m. 8520003

32

In convection heating, a heating body is used to warm the air which then distributes – transfers – heat as it fl ows over the surfaces of the objects to be heated. Most electrical convector heaters that our fi rm distributes come with a precise electronic thermostat as standard, with a contact variation of +0.5 °C.

Radiant convection heatersThese products combine within themselves the advantages of two different systems– infrared radiant heating (radiant heat, more economical operation, even distribution of temperatures, pleasant microclimate) and convection heating (excellent dynamics, advan-tageous price/performance ratio). Radiant convection heaters can also eliminate, to a large degree, the so-called “cold fl oor” effect thanks to the radiation of heat and are therefore suitable mainly for fl ats, schools and offi ces.

Direct-heating convection heatersSimple, undemanding heaters which have zero maintenance requirements and are easy to install. Exceptional operating pa-rameters can be attained thanks to the use of precise electronic thermostats. FENIX ECOFLEX convection heaters are among the few such units that can be controlled via a pilot wire.

ECOFLEX®

convectors

ECOFLEX ET – electric convector with electronic thermostat and pilot wire, 4–5 °C setback control, 230 V/50 Hz. Colour: white (RAL 9016) with white grid. IP 24, class II; can be installed on C and D fl ammable surfaces; needed clearance (cm): bottom edge, 15 / top edge, 15 / front side, 15

IP 24 Type [W] Dimensions [mm] Weight [kg] Quantity on pallet Cat. No.

ECOFLEX ET 500 500 360×400×80 3.3 28 5415305

ECOFLEX ET 750 750 360×400×80 3.3 28 5415307

ECOFLEX ET 1000 1000 440×400×80 3.8 26 5415310

ECOFLEX ET 1250 1250 520×400×80 4.4 24 5415312

ECOFLEX ET 1500 1500 600×400×80 4.9 20 5415315

ECOFLEX ET 1750 1750 760×400×80 5.8 12 5415317

ECOFLEX ET 2000 2000 840×400×80 6.6 12 5415320

ECOFLEX ET 2500 2500 1000×400×80 7.6 12 5415325

ECOFLEX G – glass convector with electronic thermostat and pilot wire, 4–5 °C setback control, 230 V/50 Hz. Available in black, red, or yellow-green.IP 24, class II; needed clearance (cm): bottom edge, 15 / top edge, 15 / front side, 15. While stocks last.

IP 24 Type [W] Dimensions [mm] Weight [kg] Quantity on pallet Cat. No.

ECOFLEX G 10 1 000 500×520×100 14 6 54367X0

ECOFLEX G 15 1 500 660×520×100 18 6 54367X2

ECOFLEX G 20 2 000 820×520×100 27 3 54367X4

33

ATLANTIC F 117 – electric convector with electronic thermostat and pilot wire, for areas not requiring precise temperature regulation, such as stores and workshops. Colour: white (RAL 9016) with white grid.IP 24, class II; can be installed on C and D fl ammable surfaces; needed clearance (cm): bottom edge, 15 / top edge, 15 / front side, 15

IP 24 Type [W] Dimensions [mm] Weight [kg] Quantity on pallet Cat. No.

ATLANTIC F117-05 500 431×493×121 3.5 28 5412150

ATLANTIC F117-07 750 431×493×121 3.5 28 5412152

ATLANTIC F117-10 1000 508×493×121 3.7 26 5412154

ATLANTIC F117-12 1250 579×493×121 4.6 24 5412156

ATLANTIC F117-15 1500 654×493×121 5.3 21 5412158

ATLANTIC F117-20 2000 801×493×121 6.2 18 5412162

ATLANTIC F117-25 2500 950×493×121 7.1 12 5412164

ECOFLEX PREMIER – radiant convector with electronic thermostat and pilot wire, 3.5 °C setback control, 230 V/50 Hz. Colour: white (RAL 9016) with white grid.IP 24, class II; needed clearance (cm): bottom edge, 15 / top edge, 10 / front side, 100

IP 24 Type [W] Dimensions [mm] Weight [kg] Quantity on pallet Cat. No.

ECOFLEX PREMIER 1000 600×450×115 4.9 16 5435130

ECOFLEX PREMIER 1500 800×450×115 5.8 10 5435132

ECOFLEX PREMIER 2000 1000×450×115 7.7 10 5435134

SOLIUS – radiant convection heater with electronic thermostat, and pilot wire. Colour: white casing (RAL 9016), white grille; IP rating 24; protection class II.; option of installation on a type C or D combustible base; clearance distances: bottom edge 15cm / side and top edge 10 cm / front wall of the device 100 cm

IP 24 Type [W] Dimensions [mm] Weight [kg] Quantity on pallet Cat. No.

SOLIUS 750 520×450×98 5.3 20 5435140

SOLIUS 1000 595×450×98 6.0 20 5435142

SOLIUS 1500 815×450×98 8.1 13 5435144

SOLIUS 2000 1035×450×98 10.2 11 5435146

CH 2000 B TURBO – portable convector with electromechanical thermostatIP 20, class I; needed clearance (cm): bottom edge, 5 / top edge, 10 / front side, 5

IP 20 Type [W] Dimensions [mm] Weight [kg] Quantity on pallet Cat. No.

CH 2000B - TURBO 750/1250/2000 580×375×110 5.0 20 5410010

34

THERMOSTATS AND CONTROLSProduct Description Cat. No.

DIGITAL PROGRAMMING THERMOSTATS

FENIX TFT

Digital touch screen thermostat; option of selecting the background colour. Operating modes ‘fl oor only’, ‘room only’, ‘fl oor+room’; option of measurement with the help of two external (fl oor) probes, PWM (PID) regulation or fi xed temperature difference. 4 preset and 3 user programmes (10 temperature changes in 15 minute steps, with the shortest time period being 1 hour). Modes: according to the programme, manual mode, holiday, party, non-freezing temperature, switched off. 16 A switching contact; range of temperature set-tings 5–35 °C in 0.5 °C steps; option of setting the min. and max. fl oor temperature; calibration of sensors. A fl oor probe is included with the thermostat. IP 21 rating.

4200152

WATTS 760

Programmable thermostat with Fuzzy-Logic option (so-called Intelligent Thermostat) or fi xed temperature difference (settable at 0.5–7 °C). Operating modes “fl oor only”, “room only”, “fl oor + room”. 5 preset + 2 user programmes – up to 12 temperature changes/day with the user programmes. Room temperature setting 5–37 °C in 0.5 °C steps. Option to set a max. and min. fl oor temperature. Setting of switched wattage for the exact correction of the room temperature, 16 A switching contact, holiday operation, permanent tempera-ture mode, switch, key lock, display backlight, choice of two frames – square, round. IP 21 rating. The back-up of data is provided by a lithium battery – the fi rst charging session must last at least 24 hours (it is for formatting the capacity of the battery).

4200123

Aube TH 232

This digital thermostat with settable temperature readings (room only / fl oor + room / fl oor only) is suitable for radiant panels, convection heaters and also fl oor heating. The thermostat has a 1-week program – it is possible to switch between the comfort (‘day’) and attenuation (‘night’) temperature up to 4 times per day. Other functions: holiday mode, non-freezing temperature mode, option of temporary temperature adjustment, display of current temperature, self-learning mode option (‘fuzzy logic’). IP 21 rating, 16 A switching contact. A 3 m fl oor probe is part of the thermostat. 230 V power supply. An AC 130-03 snubber must be connected to the thermostat circuit during the switching of induction load (e.g. when the heating is connected via a contactor) – it should be as close to the contac-tor as possible, ideally directly at its contacts. Without the snubber, spontaneous resetting of the thermostat will take place. This snubber is included with the purchased thermostat.

4200118

FENIX Therm 350

Programmable digital thermostat with Fuzzy-Logic (so-called Intelligent Thermostat) and three separate functions: room and fl oor thermostat, fl oor thermostat (factory set) or room thermostat; two preset programs, possible to use own settings. Each day can be set sepa-rately, four events per day. Air temp. range/fl oor range 5–37 °C, 16 A, frost protection program, IP 21, power reserve 36 hours, 230 V; equipped with a LED dual function, switch on/off, lock, adaptive function and switch-on time (as a percentage for the last 24 hours, 7 days, 30 days or 365 days). Floor probe is part of the package.

4200128

EBERLE FIT 3U

Programmable thermostat with PWM regulation or fi xed temperature difference. Operating modes “fl oor only”, “room only”, “fl oor + room”. 13 programmes – 9 pre-set, 4 for users (4 temperature changes per day in 30 minute steps), holiday operation, permanent tem-perature or permanent attenuation modes, maintenance of a selected temperature for a set period. Temperature settable from 5–37°C in 0.5 °C steps (fl oor and room). Option to set the max. and min. fl oor temperature, option of probe calibration. Technical parameters: 16 A switching contact, switch, key lock, back-lit display, automatic change to summer time. Floor probe is part of the package. Lithium battery used for data back-up – the fi rst charging must last at least 24 hours (formatting of the capacity of the battery), IP 30.

4065005

VTM 3000

Selection of weekly or daily programme, selection of the modes “fl oor only”, “room only”, “fl oor + room”. 6× daily switching between the pre-set comfort and attenuation tempera-tures. Option to manually change the temperature with an automatic return to the pro-gramme. Other functions: permanent maintenance of comfort or attenuation temperatures, anti-freeze protection, permanent maintenance of manually set temperature (simulation of an analogue thermostat), setting of max. and min. fl oor temperature, operating hour coun-ter. Data and programme back-up in the EEPROM memory (up to 10 years), time and date back-up with the help of a large-capacity capacitor – period of back-up 6 hours. Technical parameters: switching contact 16 A / 230 V, max. switched wattage 2 kW, key lock, fl oor probe part of the package. IP 31.

4200134

35

Product Description Cat. No.

ANALOG THERMOSTAT

FLASH 25800 10 A, bimetallic thermostat with signaling, without temperature setback, 5–35 °C, IP 30. 4200110

EBERLE RTR - E 6124 10 A, with temperature setback 5 K, accuracy 0.5 K, 5–30 °C, IP 30. 4066020

FENIX-Therm 100 12 A, IP 21, heat differential of 0.5 °C, switch, 0–45 5–30 °C (ambient air), 5–50 °C (fl oor) 4200130

Frame for FENIX-Therm 100 Frame for use in wall mounting. 4200131

TH 810 T

This outlet thermostat adjusts the outlet according to the set room temperature. Temperature range is 5–30 °C (±1 °C). Optional mode for cooling/heating. Maximum switched cur-rent is 16 A (3,500 W). Maximum time for backed-up operation is 3 hours. Displays both set and current temperature in the room. Does not allow time programming. IP 20.

4065110

WIRELESS REGULATION

Watts V22 Wireless room thermostat with 1-week programming – intended for the control of electric heating (fl oor or ceiling heat-ing, radiant panels, convection heaters) which it switches on/off via V23/25 receivers (max. 4 per V22 unit, only one of which is furnished with a fl oor probe). Parameters: operating modes Comfort, ECO, Stop, Anti-freeze protection, Holiday, 1-Week programme – interval for setting 30 min. Placement on a wall or independently on a stand (power supply: 2x AAA), programme back-up in EEPROM memory (10 years), 868 MHz bidirectional wireless communication, display of set/real temperature, reading of room temperature with an internal or cable sensor (both sensors cannot be used simul-taneously; the cable probe isn´t included). The thermostat is also designed for a wireless central regulation system with the V24 control unit (modular system, can be retrofi tted) – when connected in this way it reads the room temperature for the V24 control unit and enables temporary changes to be made.

4500410

Watts V23Wireless receiver with optional fl oor probe connection – normally controlled by the V22 thermostat, it switches the con-nected heating on/off and can also optionally read the fl oor temperature using a fl oor probe (not included). It passes on fl oor temperature information to the V22 thermostat. Parameters: placement on a KU 68 wiring box, 16 A switching contact, 230V/50Hz, IP21 rating, terminals for fl oor probe connection, LED indicates operational status. When con-nected to the central regulation system it is controlled directly by the V24 control unit, which conveys fl oor temperature information (if a fl oor probe is connected).

4500413

Watts V24 central unitThe V24 control unit is a superstructural element of Watts wireless regulation (V22 thermostats, 23/25 receivers). It enables central control of a heating system – i.e. the programming and control of heating throughout a whole building from one location – and is intended for all types of electric direct-heating systems (fl oor as well as ceiling heating, radiant panels, convection heaters, ladder radiators, etc.) The unit is fi tted with a touch screen with a simple graphic interface which enables easy and intuitive control. The power supply is drawn from a 230V/50Hz mains voltage connection (placed in a wiring box); however, the V24 unit communicates with other parts of the regulation system wirelessly. One of the advantages is the modular system; a V24 central control unit can be added to a wireless system some time after that system was installed, or, vice versa – other regulation units (V 22/23/25) can be added to a system where a V24 unit has already been installed. The V24 central unit can control up to 24 rooms/zones, and an individual programme mode can be created for each zone. A Watts V27 GSM module can also be connected to the V24 unit, enabling basic control of the heating system via short text messages.

4500408

Watts V25Wireless plug socket receiver – normally controlled by the V22 thermostat, it switches appliances on/off that are fi tted with a plug (heating ladders, portable heaters). It does not read temperatures or enable the connection of an external sensor. Parameters: 16 A switching contact, 230V/50Hz, IP20 rating, operational status indicated by LED. When con-nected to the central regulation system it is controlled directly by the V24 control unit. If there is no room temperature sensor in the room (e.g. a V22 thermostat), it only works in the ON/OFF mode.

4500416

Watts V20The Watts V20 remote control allows, through the Watts V23/V25 receiver, comfortable hand turning on or off an ap-pliance (heater usually), or starting the “TIMER” program - the heater is put into operation and turns off automatically after 2 hours. Combining the V23/25 receiver with the V20 remote control is ideal for supplemental zone heating – for example to control an ECOSUN TH terrace heater. ATTENTION: In this combination, neither the V23/25 receivers nor the V20 controller scan any temperature. If the heater is not equipped with a built-in thermostat (such as ECOFLEX con-vectors), it is operated only in the On/Off mode, without dependence on air temperature or design.

4500424

GSM module Watts V27The Watts V27 module enables basic control of a whole Watts central regulation system via connection to a V24 central unit. It is possible to fi nd out current temperatures, implement temporary changes in temperature (valid until the next pro-gramme change) or change the mode of a zone completely (Auto/Manual/Non-freezing) in a selected zone (or in all of them at once) via short text messages. It is also possible to start or prematurely end the Holiday mode. Also, the V24 control unit can send information in the opposite direction about the status of individual zones or about possible error reports. The GSM module has a slot for a SIM card (not included with the product), and it can be attached to the V24 unit either via a cable or wirelessly, which allows its placement in areas with a good signal from the GSM network. The V27 module itself is powered via a network adapter. WARNING: the module can only be connected to a Watts V24 unit.

4500422

Watts fl oor probeThis fl oor probe is designed to read fl oor temperatures; however, it can also be used to read air temperatures. Parameters: length 3m, cable diameter 4mm (thermistor 6mm), PVC sheath, resistance 10 kΩ at 25°C, suitable for Watts V23 receivers or Watts V22, Fenix TFT or Watts 760/860 thermostats.

4200129

WS-1 regulation setThe WS-1 regulation set is intended for the wireless control of electric heating – fl oor, ceiling, radiant panels, convectors and ladder radiators. It is particularly suitable for supplementary heating installations – it isn´t necessary to connect the thermo-stat to the receiver using wires. The set contains 1 V22 room thermostat with a 1-week program and 1 V23 wall-mounted receiver (see the individual elements for their technical description). The set can be extended to include three further Watts V23/V25 receivers (other switched heaters) and they can be linked via the wireless central regulation system to the V24 control unit (modular system).

4500419

NEW

36

Product Description Cat. No.

INDUSTRIAL ROOM THERMOSTAT – ANALOG WALL-MOUNTED THERMOSTATS WITH INCREASED PROTECTION (IP 54)

EBERLE AZT - A 524510 Built-in space sensor and exterior scale. Ambient air sensor 5–35 °C, 10 A, accuracy 1–5 K. 4066010

EBERLE AZT - A 524410 Built-in space sensor and exterior scale. Ambient air sensor -15–15 °C, 10 A, accuracy 1–5 K. 4066005

EBERLE AZT - I - 524510 Built-in space sensor and interior scale. Ambient air sensor 5–35 °C, 10 A, accuracy 1–5 K. 4066012

EBERLE AZT - I - 524410 Built-in space sensor and interior scale. Ambient air sensor -15–15 °C, 10 A, accuracy 1–5 K. 4066007

INDUSTRIAL THERMOSTATS WITH SEPARATE SENSOR

EBERLE UTR/60 16 A, exterior/interior control, temperature range 0–60 °C, 230 V, 1 switch, IP 65. 4066037

EBECO EB 800

Digital thermostat with an LCD display for mounting on a DIN rail (2 modules) – 1×16 A switching contact, option of connecting a second temperature sensor (room or fl oor), operating hours counter, programmable (1-week programme), ventilation function (open window), settable hysteresis, option of connecting an alarm for when set temperatures are exceeded. Universal use – heating control in standard rooms (including fl oor heating), cooling control, use in industrial or outdoor applications, differential thermostat function. Contents of packaging: EB 800 thermostat, E 85 816 71 cable sensor (3 m; range −15°C to +75°C); installation manual.

4200170

CONTROLLERS FOR GUTTERING AND OUTSIDE SURFACE HEATING

Eberle EM 524 89 (one-zone)

Regulator for the heating of eaves troughs, downpipes and outdoor surfaces – pavements and drives. In contrast with a manual or thermostatic controller it enables the achievement of operating cost savings of up to 80 %. Functions: setting of temperature and humidity, operating hours counter, alarm output, delayed switching off, current temperature indica-tor. Placement on a DIN strip (8 modules), CZ menu. The presence of humidity (water, snow or ice) and the outdoor temperature are monitored with the help of external sensors which need to be ordered separately – for eaves troughs or free areas, depending on the application. IP 20.

4600015

Eberle EM 524 90 (two-zone)

A two-zone regulator for the heating of eaves troughs, downpipes and outdoor surfaces. The parameters and functions are the same as for the EM 524 89. However, the regulator enables independent monitoring and control of two applications simultaneously. Basically, these are two EM 524 89 regulators in one. Both zones require the connection of their own set of sensors – for eaves troughs or free areas, depending on the application – and these need to be ordered separately. IP 20.

4600016

Set of EBERLE sensors for eaves troughs

Humidity (ESD 524 003) and temperature (TFD 524 004) sensor for EM 524 89 and EM 524 90 regulators for controlling the heating of eaves troughs and downpipes. IP 65. 4600051

Set of EBERLE ground sensors

Humidity (ESF 524 001) and temperature (TFF 524 002) sensor for EM 524 89 and EM 524 90 regulators for controlling the heating of outdoor surfaces. IP 65. 4600050

EBERLE DTR-E 3102Differential thermostat, 230 V, 1 × switching off / 1 × switching contact 16 A, 20–35 °C, IP 65 (can be placed e.g. on the facade). While being operated it requires careful monitor-ing to attain economical operation.

4066038

EBECO EB 800 For details see above – Industrial thermostats with separate sensor 4200170

REGULATORS TO CONTROL ATTENUATION AND TIME PROGRAMMABLE SWITCHES

FLASH Programmer 2 SED

This regulator uses a pilot wire for switching between comfort and attenuation tempera-tures. There is the option to divide a building into two zones and set individual weekly programmes for each of them. A week is divided into 7 days; each day can be allocated one of three pre-set programmes or an individual programme can be created (different for each day). In the case of individual programming, a day is divided into 30-minute intervals. There is the option of “holiday” operation – a temperature above freezing point (+7 °C) is maintained for a period of 1 to 99 days, followed by a return to the programme mode. Outputs: sinusoid 230 V / 50 Hz, positive and negative half-wave, the potential of a neutral conductor for all types of convectors and thermostats. Dimensions 83×70×17 mm, pro-gramme back-up 12 hours, IP 30 rating. Placement on KU 68.

4100025

REGULATORS FOR REDUCTION OF MAIN CIRCUIT BREAKER VALUE

Three-phase current-load reliever – 6 modules.

BMR HJ 103Three-level regulation with breaking for three phases, 3×3 A, current settings of 1 to 120 A with precision to 1 A. IP 20.Placement on DIN rail (6 modules).

4200232

BMR HJ 306Two-level regulation with separate breaking for individual phases, 6×3 A, current settings of 1 to 120 A with precision to 1 A, size 6 modules. IP 20.Placement on DIN rail (6 modules).

4200032

37

1 2

3

4

5

6

7

8

9

10

1 storage bricks 2 Heating elements 3 Microtherm® insulation 4 Charge controller 5 Bypass system 6 Wall bracket 7 Charge adjustment 8 Vermiculite insulation 9 Fan 10 Auxiliary heating element (optional)

STORAGE HEATERS

ECODYNAMIC – Dynamic Storage HeaterBasic Characteristics and Benefi ts

Electric fan storage heater with controllable heat output according to the Standards DIN 44574, IEC 60531 and the Safety Standard VDE 0720

Equipped with a thermomechanical charge controller (liquid fi lled) and a thermomechanical safety controller (bimetal)

Airfl ow in two channels inside the core One brick type for all heater models (material: magnesite MgO) High-quality Vermiculite and Microtherm® insulation (achieving lower surface temperatures and better heat accumulation)

Only 25 cm deep No start-up procedure; may be operated by user immediately after installation Tube heating elements (special alloy steel) Radial fl ow fan for quiet and steady heat output Discharge controlled with an external room thermostat* Air outlet with bimetal fl ap system for high and constant heat output (automatic) Auxiliary heating element* installed in the air outlet area Sheet steel casing, phosphatized and enameled; colour: creme-white with gray-brown air outlet grill

With a wall spacer and either supporting feet* or a fl oor plate* Protective cover* for bathrooms

IP X0 Type Input [kW] Max. capacity [kWh] Voltage [V] Dimensions [mm] Weight [kg] Cat. No.VFMi 20 2.0 16

factory setting 400–3N~50Hz may be changed

by a qualifi ed technician to 230~50Hz

626×672×250 98 5604020VFMi 30 3.0 24 776×672×250 137 5604030VFMi 40 4.0 32 926×672×250 176 5604040VFMi 50 5.0 40 1076×672×250 215 5604050VFMi 60 6.0 48 1226×672×250 254 5604060VFMi 70 7.0 56 1376×672×250 293 5604070

* available by special order

ECOSTATIC – Static Storage HeaterBasic Characteristics and Benefi ts

Manually controlled electric storage heater Input and output adjustment according to the required comfort

Attractively styled to suit modern home and offi ce decor Very low lifetime maintenance Safe, easily controllable and highly reliable Upgraded and adjusted for use in bathrooms (IP X2)

IP X2 Type Input [kW] Max. capacity [kWh] Voltage [V] Dimensions [mm] Weight [kg] Cat. No.WMX 706 * 0.85 6

230~50Hz

332×700×183 41 5604706WMX 712 1.70 12 560×700×183 77 5604712WMX 718 2.55 18 788×700×183 110 5604718WMX 724 3.40 24 1016×700×183 140 5604724

IP 20 rating; class I.; electromechanical thermostat for the limitation of charging + electromechanical thermostat for the control of discharging; * the WMX 706 type is without controlling thermostats; option of installation on a C or D fl ammable base; Needed clearance: side edges 75 mm, top edge 250 mm, front wall 300 mm

IP 20 rating; class I.; electromechanical thermostat for the limitation of charging; option of installation on a C or D fl ammable base; Needed clearance: side and top edge 100 mm, front wall 300 mm

38

Type Capacity [l] Voltage [V] Input [W] IP protection Heating time Net weight [kg] Height [mm] Diameter [mm] Cat. No.

ATL 10 L 10

220–240

1600 IP 25 0h 24min 8 456 255 5451001

ATL 10 LU 10 2000 IP 24 0h 19min 8 456 255 5451002

ATL 50 L 502000

IP 25

1h 30min 16 559 433 5455001

ATL 80 L 80 2h 26min 20 791 433 5455010

ATL 150 L 150 2200 4h 36min 40 1241 505 5455030

ATLANTIC electric water heater

Local heating not only provides you extra comfort, it also conserves electricity and water. Since these heaters are quite small, you can easily build one into a kitchen counter or the cabinet under the sink. Your kitchen’s aesthetics can thereby be preserved.

Principal characteristics and advantagesLow-volume units heat water very close to the place where it is to be used. This eliminates the large losses typical of central hot water sources, where pipes leading from the central boiler sap the water’s heat as they pass through walls.

thermal insulation from polyurethane foam hot water outlet pipe enameled inner pressure tank exchangeable magnesium anode thermostat temperature sensor cold water inlet electrical heating element removable access fl ange thermostat

HAND DRYERS – electric hot-air units with fans for hand drying. Wall-mountable. Automatic sensor switch ensures hygienic operation. Type ZY - 202 (metal) – while stocks last.

Type Output Switching sensor

Air temperature Tension Dimensions

[mm]Weight

[kg] Cat. No.

ZY - 203 A (plastic) 1800 W 14–18 cm 50–70°C ~230 V 50 Hz

240×240×240 2.5 5440010ZY - 202 A (metal) 2700 W 12–18 cm 45–55°C 361×242×156 5.0 5440005

SUPPLEMENTARY PRODUCTS

TUBULAR HEATING ELEMENTS – with an electric heating insert. Intended primarily for bathrooms – suitable for drying bath towels, hand towels, etc.

ZY - 203 A (plastic)

ZY - 202 A (metal)

ELECTRIC TOWEL DRYERS are intended mainly for use in bathrooms, washrooms, showers or kitchens for the drying of damp towels, bath towels, tea towels, etc. Installation is simple – the dryer is attached to the wall using three plastic grips and the supply lead is connected to a standard socket. The heating element is protected from overheating by a thermal fuse; the element doesn’t contain any fi lling and therefore there is no danger of freezing, air intake or leakage of the liquid.

Type sTR - CR (chrome) – while stocks last.

Type Colour Width [mm]

Height [mm]

Depth [mm]

Weight[kg] Cat. No.

STR - W white 590 662 25 3.9

5441006STR - CR chrome 5441007

Output 100 W, voltage 230 V / 50 Hz, IP 44 rating, insulation class I., switch with a light which signals operation, 1.6 m long straight supply cable with a plug.

IP 65 rating. Voltage 230 V / 50 Hz. White RAL 9016; fi lled with non-freezing mixture, 1 m coiled connection cable (extends to 3.5 m) with plug. Mounting brackets are included with the product. The heating element is without a thermostat. It can be combined with a TH 810 T plug-in thermostat.

the element doesn’t contain any

Type Wattage Width [mm]

Height [mm]

Depth [mm]

Weight[kg] Cat. No.

KD-E – fl at

KD-E 450×960 300 450 960 90 11.5 5441402KD-E-600×960 400 600 960 90 13.0 5441404KD-E-450×1320 400 450 1320 90 15.8 5441406KD-E-600×1320 600 600 1320 90 18.0 5441408KD-E-750×1680 900 750 1680 90 27.0 5441410KDO-E – rounded

KDO-E 450×960 300 450 960 120 11.5 5441412KDO-E 600×960 400 600 960 120 13.0 5441414KDO-E 450×1320 400 450 1320 120 15.8 5441416KDO-E 600×1320 600 600 1320 120 19.0 5441418KDO-E 750×1680 900 750 1680 120 27.0 5441420

ArgentinaArmeniaAustraliaAustriaBelarusBeneluxBosnia and HerzegovinaBrazilBulgaria

CanadaColumbiaCroatiaCyprusCzech RepublicDenmarkEstoniaFinlandFranceGeorgia

GermanyGreat BritainGreeceHungaryChileIranIrelandIsraelItalyJapan

KoreaKazakhstanKingdom of JordanLatviaLebanonLithuaniaMacedoniaMaltaMontenegroNetherlands

New ZealandNorwayPolandPortugalRomaniaRussiaSerbiaSlovakiaSloveniaSpain

SwedenSwitzerlandTajikistanTurkeyUkraineUruguayUSA

EXPORT MARKETS

www.fenixgroup.eu

HEADQUARTERS FENIX GROUP a.s.Šárecka 37, 160 00 Praha 6, Czech Republic E-mail: [email protected]

FLEXEL INTERNATIONAL LTD.Glenrothes, Fife, Scotland www.fl exel.co.ukE-mail: sales@fl exel.co.uk

CEILHIT, S.L.Poligono Industrial Cami RalC/Galileo 38-40, 08850 Gava, SpainE-mail: [email protected]

FENIX TRADING s.r.o. Slezská 2, 790 01 Jeseník, Czech Republic

Tel.: +420 584 495 111, 584 495 302Fax: +420 584 495 303

E-mail: [email protected]

PRODUCTION PLANTFENIX s.r.o., Jaroslava Ježka 1338/18a790 01 Jeseník, Czech RepublicE-mail: [email protected]

FLEXEL INTERNATIONAL LTD.

FENIX SLOVENSKO s.r.o.Iliašská cesta 86

974 01 Bánská Bystrica, SlovakiaE-mail: [email protected]

CEILHIT, S.L.

ACSO11 bis, boulevard carnot – 81270

Labastide-Rouairoux, FranceE-mail: [email protected]

www.fenixgroup.euFENIX TRADING s.r.o. Slezská 2, 790 01 Jeseník, Czech Republic;

Tel.: +420 584 495 111, 584 495 302; Fax: +420 584 495 303; E-mail: [email protected]