43
Product Update and Overview 2016 Elliot Fixler Northeast Regional Manager “We are driven to produce products our customers really wantSpectrum Controls, Inc.

Product Update and Overview 2016 - Kendall Group

  • Upload
    others

  • View
    1

  • Download
    0

Embed Size (px)

Citation preview

Product Update and Overview 2016

Elliot Fixler Northeast Regional Manager

“We are driven to produce products

our customers really want”

Spectrum Controls, Inc.

The Fine Print……….

• Spectrum Controls Inc established 1983

• Located in Bellevue, Washington –

• Bruce Wanta President and Owner -

• +80 employees, over ½ of which are development

engineers, hardware and software

The Partnership……….

• Rockwell Automation

Distribution Network

• I/O Technical Support by Rockwell Automation

Worldwide phone support, sample projects, app support,

knowledge base

• Proposal Works & Integrated Architecture

Builder

The Products……….

• InView Marquee Displays

• Speciality I/O Modules – NEW Powerflex Drives

• analog input module - ControlLogix, CompactLogix, MicroLogix, Flex I/O,

Point I/O, Micro 800 2080 and Micro 850 2085

• Analog +HART modules for CompactLogix and Point I/O

• WebPort and WebPort CONNECTS remote access solution

“InView” from SC

Why InView Marque displays? • Install once, set it and forget it

• “Industrial Hardened”

15+ year lifespan, 24/7 duty cycle, ideal in harsh environments

program via 232 / 485, amperage spikes not an issue

• Viewing distance up to 450’

• Vastly superior viewing angle than most LCD & LED displays

• Rockwell centric programing and set-up with RA PLCs,

• RA TechConnect support included with purchase

• https://www.youtube.com/watch?v=8eM6G831itU

“InView” from SC

InView –Industrial Marquee Display

– Ethernet/IP, ControlNet and DeviceNet,

including TCP/IP passthrough

• Red, tri-color or RGB color display,

• NEMA 12, 4, 4X SST enclosures available

• Dynamic messaging for real time information

• Custom bitmap characters

• Temp ranges 0*C to +55*C (32*F to 131*F)

• Vibration 2g, Shock operating 15g

SC I/O Products……….

RA Compatibility –

• look and feel like RA I/O

• Program w/ RA programming

software you already own

ROI – OEM, SI’s, EU’s, SP’s

• High-density, increase value per point

• Point per point versatility (Universals)

• Isolation, ch to ch, ch to backplane

• Access to new markets (BacNet)

PowerFlex Drives Module……

Just Released!

20-750sc-8U 8-ch universal

Analog Input Module

•Protect the drive long term by monitoring

motor operation / heat generation

•Monitor power consumption, running time,

throttle up at peak times, throttle back at off-peak usage times, etc.

•Monitor loop control feedback, fans and pumps, air-flow, control tension in S

loops, etc

•Preventative feedback – throughout the system

The power consumption savings alone can be huge – is this an issue?

PowerFlex Drives Module……

20-750sc-8U 8-ch Universal

Analog Input Module

•current, voltage, RTD or resistance (RTD uses channel pairs)

• 250 VAC channel-to-chassis ground isolation;

10VDC channel-to-channel isolation

• High density analog input module /16 bit resolution with selectable input filters,

Channel selectable filtering for fastest analog update time

• Configured with CCW software (Data Links / mapping), 3 slots (4,5,6) in the drive

for up to 24 analog inputs total per drive

Tenter Oven

Micro 800 2080 Series…….

2080sc-BAC

BACnet + BACNET/IP

Communications Plug-In Module

• BACnet Compliant interface allowing you to turn

your Micro800 series PLC into a BACnet Application

Controller.

Micro 820, 830, 850 Series PLCs

• Interface to BACnet serial and Ethernet Building Automation Networks

• Integrate with HVAC, Lighting, Access, or Application Controller

• Easy browser-based configuration w/ Spectrum configuration tools and CCW

*minimum order qty 10 pcs pkg

Micro 800 2080 Series…….

2080sc-NTC

4-ch Thermister Input Module -

•This module works in tandem w/ BACnet module

•Thermister / resister inputs

• 250 VDC ch-to-chassis isolation

• Fully linearized sensor data

• AB Micro 830 and Micro 850 series

minimum order qty 10 pcs pkg

Micro 800 2080 Series…….

2080sc-IF4u - 4 Ch Universal

Analog Input module -

• Up to 4-ch

• Voltage, Current, or Thermocouple or

2-ch RTD / Resistance, (4/2-ch RTDs per module)

• 50Vdc ch-to-ch isolation

• AB Micro 830 and Micro 850 series

*minimum order qty 10 pcs pkg

Micro 800 2080 Series…….

2080sc-OW2IHC

2-ch High Current Relay

Output module -

• Up to 10A output current

• 50 Vdc ch-to-ch isolation

• AC and DC voltages

• AB Micro 830 and Micro 850 series

minimum order qty 10 pcs pkg

Point I/O +HART……..

Point I/O +HART –

1734sc-IE4H – 4 Ch Analog + HART Input

1734sc-OE2CH – 2 Ch Analog + HART Output

• Current + HART

• Asset Management compatible

(CONNECTS or DTM)

• Compatible with Enet and Cnet Adapters

• Same analog +HART functionality you’re familiar with on Logix platform…..

Point I/O Universal……..

1734sc-IF4U - 4 Ch Universal Analog Input –

• Channel selectable for multiple input types

Voltage, Current, Thermocouple, RTD, or Resistance (RTDs consumed in pairs)

• 10 Vdc ch-to-ch isolation, 50 Vdc channel to backplane

50 Vdc channel to ground isolation

• 5 input types, one module

Save rack space, exploit efficiencies using Point I/O

Flex I/O 1794 series……….

• 1794sc-IF8Iu 8-ch Universal Isolated Analog Input

Thermocouple, RTD, Resistance

Current or Voltage per channel

High density, fully isolated

• 5 input types / 1 module

• Point by point versatility in any combination

• 120 Vac isolation; ch to backplane, ch-to ch, or ch to

gound

Flex I/O 1794 series……….

• 1794sc-IRT8I 8-ch Isolated Thermocouple / RTD Input Module

Thermocouple or RTD selectable

• 2 input types / 1 module

• Point by point versatility - two combinations

• 120 Vac isolation; ch to backplane, ch-to ch, or ch to

gound

MicroLogix 1762 series……….

• 1762sc-IF8u 8-ch Universal Analog Input

Thermocouple, RTD, Resistance, Current or Voltage

(Rtds consumed in pairs)

• 5 input types / 1 module

• Point by point versatility in any combination

• Up to 16 bit resolution, 10 Vdc ch-to-ch isolaton

• Micro 1100, 1200

and 1400

MicroLogix 1762 series…….

1762sc-IF4OF4 8-ch Analog Combo Module

• 4-ch analog input, (current, voltage, or thermocouple (JKET))

• 4-ch analog output • (current or voltage)

• 3 input types, 2 output type

• Versatility input / output combination

• High Density, up to 16 bit resolution

• 10 Vdc ch-to-ch isolation, 120 ch-to chassis / ground / backplane

• Micro 1100, 1200

and 1400

MicroLogix 1762 series…….

1762sc-OF8 8-ch Analog Output Module

• Eight selectable Voltage or Current outputs, mix and match on a channel/channel basis

• High density

• Low price per point

• Up to 16 bit resolution

• 120 Vac ch-to-backplane, ch-to chassis ground

• Micro 1100, 1200

and 1400

Compact I/O 1769 series……..

• 1769sc-IF8u 8-ch Universal Analog Input

Thermocouple, RTD, Resistance, Current or Voltage (RTD consumed in pairs)

• 5 input types / 1 module

• Versatility in any combination

• 16-bit resolution

• 10 Vdc ch-to-ch isolation, 500 Vdc ch-to backplane / chassis ground

CompactLogix and MicroLogix 1500

Compact I/O 1769 series…….

1769sc-IT6I

6-ch Isolated Thermocouple Input 500 Vdc ch-to-ch, ch-to-backplane / chassis ground

1769sc-IR6I

6-ch Isolated RTD / Resistance Input 125 Vac ch-to-ch, ch-to backplane / chassis ground

• Dedicated input types

• High density

• 16-bit resolution

CompactLogix and MicroLogix 1500

CompactLogix 1769 w/HART series…

• 1769sc-IF4Ih 4-ch isolated analog input w/ HART

• 1769sc-OF4Ih 4-ch isolated analog output w/HART

• Analog +HART input types

• 16-bit resolution

• 500 Vdc ch-to-ch, 500 Vdc ch-to-backplane / chassis

• SCX-3000 CONNECTS asset connectivity software

HART series modules…

• Why analog +HART?

• Get analog signal in addition to HART data from each device on the

same twisted pair wiring

• Get more HART data from each field device

• Get HART data faster, delivered directly to the tag database

• Get more accurate HART data, no digital to analog conversions

• Eliminate hand-held communicators and calibrators

• Make process decisions faster with more accurate data

• Streamline integrated architecture processes

• Point I/O, CompactLogix, ControlLogix, Flex work much the same

Engineering

Workstation

RSLogix / Logix

RSView / RSMACC

Asset Management

AMS / DMS/ FieldCare

Visualization

RSView or

PanelView

ENet

Change Management

& Maintenance

Integrated Architecture

Hand Calibrator

ENet or CNet

Enterprise Client

Applications

ControlLogix Analog+HART I/O

HART

Field Devices

Analog and

HART Data

Analog + HART Overview

Current input +HART Data 2 module set, Input and Output Modules Each channel selectable… Voltage (1769) Current Current + HART Point to Point functionality

Instrument HART Data

• PV: Mass Flow Rate

• SV: Totalizer 1

• TV: Density

• FV: Temperature

• Volume Flow

• Std. Volume Flow

• Target Flow

• Carrier Flow

• Calculated Density

• Totalizer 2

Endress+Hauser

Mass Flow Meter

Metso Control Valve

• PV: Percent Travel

• SV: Travel Setpoint

• TV: Temperature

• FV: Supply Pressure

• Status Bytes RAM Fail

Pressure Sensor Fail

Temperature Sensor Fail

Position Sensor Fail

Read

Read

• Set Flow Units

• Reset Totalizers

• Set Zero & Full Scale Range

• Change K Factor

• Change Pipe Diameter

• Set Flow Direction

• Set “Low Flow Cutoff”

• Make Density Adjustments

Write

• Perform Diagnostic Tests

• Set Zero & Span

• Adjust For Mechanical Wear

• Adjust Valve Sensitivity

Write

Benefits of an Integrated Network, ROI

Commissioning

Efficient Documentation

Simplified Device Configuration

Operation

Real-time diagnostics

Regulatory Compliance (FDA, EPA…)

Maintenance

Automated Predictive Maintenance

Audit Trail / Self Documentation

ROI Wins with HART

Device Management Workstation vs. Field

Scheduling Reduce downtime

System Backup Fast Recovery

Historical Reference Identify Trends Determine Reliability

Device Management

Application

Software Components

Spectrum Controls

Analog+HART I/O Gateway

Rockwell Software

RSLinx

+

Workstation

HA

RT

I/O

H

AR

T I/

O

Enterprise Client

Applications

+

ControlLogix 1756 series……….

• 1756sc-IF8u 8-ch Universal Analog Input

Thermocouple, RTD, Resistance, Current or Voltage

• 5 input types / 1 module

• Versatility in any combination

• High density 8-ch Thermocouple

• High density 8-ch RTD

• 16 – 21 bit resolution based on filter settings

• 12.5 Vdc ch-to-ch isolation, 1000 Vdc ch-to-backplane / chassis

ControlLogix 1756 series……….

1756sc- CTR8 8-ch 65KHz AC / DC Pulse

Does pulse and rate at the same time

Does not include on-board outputs

• 8 single ended or 4 up/down or quadrature counters

• 8-ch Turbine Flow meter includes scaling K factor, and meter proving requirements

SLC-500 1746 series……….

1746sc-NI8u …. 8-ch universal analog Input

Current, voltage, RTD, thermocouple, or resistance

1746sc-CTR4 / CTR8 …. 4/8-ch AC/DC Pulse Input 50KHz Counter or Flow meter

1746sc-INI4i, -INI4vi …. 4-ch isolated analog input

Current only or current / voltage selectable

1746sc-INO4i, -INO4vi …. 4-ch isolated analog output Current only or current / voltage selectable

1746sc-IA8I, IB8I, IC8I, IM8I …. 8-ch isolated digital

input modules 120V, 24V, 48V, and 200/240V

1746sc-OAP8I …. 8-ch isolated AC triac output module, 74-276V

Specialty I/O from Spectrum Controls

Questions regarding

The Spectrum Controls

I/O offering?

What does Remote Access

mean to you?

WebPort and WebPort CONNECTS……..

OEM Business Solution –

2 best reasons for implementing remote access -

• Reduce initial install and commissioning costs

• Reduce overall service and support costs including travel

time & expenses

End User Business Solution –

2 best reasons for implementing remote access is to….

• reduce downtime, get back up and running faster

increasing production

• reduce ongoing service & support costs

• But wait, there’s more!

• reduce on-site install / start-up times

• reduce wear and tear / attrition for critical employees by

implementing remote access

WebPort and WebPort CONNECTS……..

Why WebPort secure remote access?

• Dramatically reduce overall system costs, at startup and

commissioning, warranty support and non-warranty

support

• Faster response time, more uptime

• Secure access for troubleshooting

• Alarms & notifications, predictable maintenance

• Data logs to make more informed decisions faster

• Features scale to your business growth and customer

requirements, hardware costs are fixed

WebPort and WebPort CONNECTS……..

• Why WebPort and WP CONNECTS?

• Island of automation sales approach – OEM, SI, EU solution, (as

opposed to an enterprise solution)

• A business decision – how do you want to grow your business? Set

yourself apart from your competition

• Scalable – feature set complete, set up those feature sets you need,

when you need them, fixed cost

• Firmware upgradable in the field, ideal for future growth, hardware stays

relevant - i.e. 1:1 NAT routing……

• WebPort CONNECTS - Mitigate risk by utilizing on-board VPN

technology, Microsoft Azure Platform

• Total cost of ownership – ROI during warranty will overcome increase in

BOM costs

WebPort and WebPort CONNECTS……..

Snapshot of Firmware, easy to program

WebPort and WebPort CONNECTS……..

Feature Overview

• Firmware upgradable in the field

• NAT 1:1 functionality

• Class 1, Div 2, UL 508 Industrial certified

• Secure remote access (VPN service from Spectrum

Controls WebPort CONNECTS) to controllers / PLCs,

outbound connection Port 80 or 443

• Two part numbers; Ethernet or Ethernet +3G cell modem

access (antenna kit and data plan required for cell

modem)

WebPort and WebPort CONNECTS……..

• Alarms & notifications (analog, Boolean, and complex

alarming capabilities)

• Data logging and reporting (Cloud storage via Microsoft

Azure)

• Document storage (service records, schematics, BOMs,

spec sheets, quick start guides etc.)

• Customizable dashboards and customizable reports

• User defined access and controls for multiple users

• SQL database / HTML5 development

What additional Questions can I answer?

WebPort and WebPort CONNECTS……..

Wrapping up……….

Thank YOU!

• Elliot Fixler

– Northeastern Regional Manager

[email protected]

– Cell phone # 603-770-1197

– Office phone # 425-746-9481

– www.spectrumcontrols.com