Upload
others
View
1
Download
0
Embed Size (px)
Citation preview
Product Update and Overview 2016
Elliot Fixler Northeast Regional Manager
“We are driven to produce products
our customers really want”
Spectrum Controls, Inc.
The Fine Print……….
• Spectrum Controls Inc established 1983
• Located in Bellevue, Washington –
• Bruce Wanta President and Owner -
• +80 employees, over ½ of which are development
engineers, hardware and software
The Partnership……….
• Rockwell Automation
Distribution Network
• I/O Technical Support by Rockwell Automation
Worldwide phone support, sample projects, app support,
knowledge base
• Proposal Works & Integrated Architecture
Builder
The Products……….
• InView Marquee Displays
• Speciality I/O Modules – NEW Powerflex Drives
• analog input module - ControlLogix, CompactLogix, MicroLogix, Flex I/O,
Point I/O, Micro 800 2080 and Micro 850 2085
• Analog +HART modules for CompactLogix and Point I/O
• WebPort and WebPort CONNECTS remote access solution
“InView” from SC
Why InView Marque displays? • Install once, set it and forget it
• “Industrial Hardened”
15+ year lifespan, 24/7 duty cycle, ideal in harsh environments
program via 232 / 485, amperage spikes not an issue
• Viewing distance up to 450’
• Vastly superior viewing angle than most LCD & LED displays
• Rockwell centric programing and set-up with RA PLCs,
• RA TechConnect support included with purchase
• https://www.youtube.com/watch?v=8eM6G831itU
“InView” from SC
InView –Industrial Marquee Display
– Ethernet/IP, ControlNet and DeviceNet,
including TCP/IP passthrough
• Red, tri-color or RGB color display,
• NEMA 12, 4, 4X SST enclosures available
• Dynamic messaging for real time information
• Custom bitmap characters
• Temp ranges 0*C to +55*C (32*F to 131*F)
• Vibration 2g, Shock operating 15g
SC I/O Products……….
RA Compatibility –
• look and feel like RA I/O
• Program w/ RA programming
software you already own
ROI – OEM, SI’s, EU’s, SP’s
• High-density, increase value per point
• Point per point versatility (Universals)
• Isolation, ch to ch, ch to backplane
• Access to new markets (BacNet)
PowerFlex Drives Module……
Just Released!
20-750sc-8U 8-ch universal
Analog Input Module
•Protect the drive long term by monitoring
motor operation / heat generation
•Monitor power consumption, running time,
throttle up at peak times, throttle back at off-peak usage times, etc.
•Monitor loop control feedback, fans and pumps, air-flow, control tension in S
loops, etc
•Preventative feedback – throughout the system
The power consumption savings alone can be huge – is this an issue?
PowerFlex Drives Module……
20-750sc-8U 8-ch Universal
Analog Input Module
•current, voltage, RTD or resistance (RTD uses channel pairs)
• 250 VAC channel-to-chassis ground isolation;
10VDC channel-to-channel isolation
• High density analog input module /16 bit resolution with selectable input filters,
Channel selectable filtering for fastest analog update time
• Configured with CCW software (Data Links / mapping), 3 slots (4,5,6) in the drive
for up to 24 analog inputs total per drive
Micro 800 2080 Series…….
2080sc-BAC
BACnet + BACNET/IP
Communications Plug-In Module
• BACnet Compliant interface allowing you to turn
your Micro800 series PLC into a BACnet Application
Controller.
Micro 820, 830, 850 Series PLCs
• Interface to BACnet serial and Ethernet Building Automation Networks
• Integrate with HVAC, Lighting, Access, or Application Controller
• Easy browser-based configuration w/ Spectrum configuration tools and CCW
*minimum order qty 10 pcs pkg
Micro 800 2080 Series…….
2080sc-NTC
4-ch Thermister Input Module -
•This module works in tandem w/ BACnet module
•Thermister / resister inputs
• 250 VDC ch-to-chassis isolation
• Fully linearized sensor data
• AB Micro 830 and Micro 850 series
minimum order qty 10 pcs pkg
Micro 800 2080 Series…….
2080sc-IF4u - 4 Ch Universal
Analog Input module -
• Up to 4-ch
• Voltage, Current, or Thermocouple or
2-ch RTD / Resistance, (4/2-ch RTDs per module)
• 50Vdc ch-to-ch isolation
• AB Micro 830 and Micro 850 series
*minimum order qty 10 pcs pkg
Micro 800 2080 Series…….
2080sc-OW2IHC
2-ch High Current Relay
Output module -
• Up to 10A output current
• 50 Vdc ch-to-ch isolation
• AC and DC voltages
• AB Micro 830 and Micro 850 series
minimum order qty 10 pcs pkg
Point I/O +HART……..
Point I/O +HART –
1734sc-IE4H – 4 Ch Analog + HART Input
1734sc-OE2CH – 2 Ch Analog + HART Output
• Current + HART
• Asset Management compatible
(CONNECTS or DTM)
• Compatible with Enet and Cnet Adapters
• Same analog +HART functionality you’re familiar with on Logix platform…..
Point I/O Universal……..
1734sc-IF4U - 4 Ch Universal Analog Input –
• Channel selectable for multiple input types
Voltage, Current, Thermocouple, RTD, or Resistance (RTDs consumed in pairs)
• 10 Vdc ch-to-ch isolation, 50 Vdc channel to backplane
50 Vdc channel to ground isolation
• 5 input types, one module
Save rack space, exploit efficiencies using Point I/O
Flex I/O 1794 series……….
• 1794sc-IF8Iu 8-ch Universal Isolated Analog Input
Thermocouple, RTD, Resistance
Current or Voltage per channel
High density, fully isolated
• 5 input types / 1 module
• Point by point versatility in any combination
• 120 Vac isolation; ch to backplane, ch-to ch, or ch to
gound
Flex I/O 1794 series……….
• 1794sc-IRT8I 8-ch Isolated Thermocouple / RTD Input Module
Thermocouple or RTD selectable
• 2 input types / 1 module
• Point by point versatility - two combinations
• 120 Vac isolation; ch to backplane, ch-to ch, or ch to
gound
MicroLogix 1762 series……….
• 1762sc-IF8u 8-ch Universal Analog Input
Thermocouple, RTD, Resistance, Current or Voltage
(Rtds consumed in pairs)
• 5 input types / 1 module
• Point by point versatility in any combination
• Up to 16 bit resolution, 10 Vdc ch-to-ch isolaton
• Micro 1100, 1200
and 1400
MicroLogix 1762 series…….
1762sc-IF4OF4 8-ch Analog Combo Module
• 4-ch analog input, (current, voltage, or thermocouple (JKET))
• 4-ch analog output • (current or voltage)
• 3 input types, 2 output type
• Versatility input / output combination
• High Density, up to 16 bit resolution
• 10 Vdc ch-to-ch isolation, 120 ch-to chassis / ground / backplane
• Micro 1100, 1200
and 1400
MicroLogix 1762 series…….
1762sc-OF8 8-ch Analog Output Module
• Eight selectable Voltage or Current outputs, mix and match on a channel/channel basis
• High density
• Low price per point
• Up to 16 bit resolution
• 120 Vac ch-to-backplane, ch-to chassis ground
• Micro 1100, 1200
and 1400
Compact I/O 1769 series……..
• 1769sc-IF8u 8-ch Universal Analog Input
Thermocouple, RTD, Resistance, Current or Voltage (RTD consumed in pairs)
• 5 input types / 1 module
• Versatility in any combination
• 16-bit resolution
• 10 Vdc ch-to-ch isolation, 500 Vdc ch-to backplane / chassis ground
CompactLogix and MicroLogix 1500
Compact I/O 1769 series…….
1769sc-IT6I
6-ch Isolated Thermocouple Input 500 Vdc ch-to-ch, ch-to-backplane / chassis ground
1769sc-IR6I
6-ch Isolated RTD / Resistance Input 125 Vac ch-to-ch, ch-to backplane / chassis ground
• Dedicated input types
• High density
• 16-bit resolution
CompactLogix and MicroLogix 1500
CompactLogix 1769 w/HART series…
• 1769sc-IF4Ih 4-ch isolated analog input w/ HART
• 1769sc-OF4Ih 4-ch isolated analog output w/HART
• Analog +HART input types
• 16-bit resolution
• 500 Vdc ch-to-ch, 500 Vdc ch-to-backplane / chassis
• SCX-3000 CONNECTS asset connectivity software
HART series modules…
• Why analog +HART?
• Get analog signal in addition to HART data from each device on the
same twisted pair wiring
• Get more HART data from each field device
• Get HART data faster, delivered directly to the tag database
• Get more accurate HART data, no digital to analog conversions
• Eliminate hand-held communicators and calibrators
• Make process decisions faster with more accurate data
• Streamline integrated architecture processes
• Point I/O, CompactLogix, ControlLogix, Flex work much the same
Engineering
Workstation
RSLogix / Logix
RSView / RSMACC
Asset Management
AMS / DMS/ FieldCare
Visualization
RSView or
PanelView
ENet
Change Management
& Maintenance
Integrated Architecture
Hand Calibrator
ENet or CNet
Enterprise Client
Applications
ControlLogix Analog+HART I/O
HART
Field Devices
Analog and
HART Data
Analog + HART Overview
Current input +HART Data 2 module set, Input and Output Modules Each channel selectable… Voltage (1769) Current Current + HART Point to Point functionality
Instrument HART Data
• PV: Mass Flow Rate
• SV: Totalizer 1
• TV: Density
• FV: Temperature
• Volume Flow
• Std. Volume Flow
• Target Flow
• Carrier Flow
• Calculated Density
• Totalizer 2
Endress+Hauser
Mass Flow Meter
Metso Control Valve
• PV: Percent Travel
• SV: Travel Setpoint
• TV: Temperature
• FV: Supply Pressure
• Status Bytes RAM Fail
Pressure Sensor Fail
Temperature Sensor Fail
Position Sensor Fail
Read
Read
• Set Flow Units
• Reset Totalizers
• Set Zero & Full Scale Range
• Change K Factor
• Change Pipe Diameter
• Set Flow Direction
• Set “Low Flow Cutoff”
• Make Density Adjustments
Write
• Perform Diagnostic Tests
• Set Zero & Span
• Adjust For Mechanical Wear
• Adjust Valve Sensitivity
Write
Benefits of an Integrated Network, ROI
Commissioning
Efficient Documentation
Simplified Device Configuration
Operation
Real-time diagnostics
Regulatory Compliance (FDA, EPA…)
Maintenance
Automated Predictive Maintenance
Audit Trail / Self Documentation
ROI Wins with HART
Device Management Workstation vs. Field
Scheduling Reduce downtime
System Backup Fast Recovery
Historical Reference Identify Trends Determine Reliability
Device Management
Application
Software Components
Spectrum Controls
Analog+HART I/O Gateway
Rockwell Software
RSLinx
+
Workstation
HA
RT
I/O
H
AR
T I/
O
Enterprise Client
Applications
+
ControlLogix 1756 series……….
• 1756sc-IF8u 8-ch Universal Analog Input
Thermocouple, RTD, Resistance, Current or Voltage
• 5 input types / 1 module
• Versatility in any combination
• High density 8-ch Thermocouple
• High density 8-ch RTD
• 16 – 21 bit resolution based on filter settings
• 12.5 Vdc ch-to-ch isolation, 1000 Vdc ch-to-backplane / chassis
ControlLogix 1756 series……….
1756sc- CTR8 8-ch 65KHz AC / DC Pulse
Does pulse and rate at the same time
Does not include on-board outputs
• 8 single ended or 4 up/down or quadrature counters
• 8-ch Turbine Flow meter includes scaling K factor, and meter proving requirements
SLC-500 1746 series……….
1746sc-NI8u …. 8-ch universal analog Input
Current, voltage, RTD, thermocouple, or resistance
1746sc-CTR4 / CTR8 …. 4/8-ch AC/DC Pulse Input 50KHz Counter or Flow meter
1746sc-INI4i, -INI4vi …. 4-ch isolated analog input
Current only or current / voltage selectable
1746sc-INO4i, -INO4vi …. 4-ch isolated analog output Current only or current / voltage selectable
1746sc-IA8I, IB8I, IC8I, IM8I …. 8-ch isolated digital
input modules 120V, 24V, 48V, and 200/240V
1746sc-OAP8I …. 8-ch isolated AC triac output module, 74-276V
OEM Business Solution –
2 best reasons for implementing remote access -
• Reduce initial install and commissioning costs
• Reduce overall service and support costs including travel
time & expenses
End User Business Solution –
2 best reasons for implementing remote access is to….
• reduce downtime, get back up and running faster
increasing production
• reduce ongoing service & support costs
• But wait, there’s more!
• reduce on-site install / start-up times
• reduce wear and tear / attrition for critical employees by
implementing remote access
WebPort and WebPort CONNECTS……..
Why WebPort secure remote access?
• Dramatically reduce overall system costs, at startup and
commissioning, warranty support and non-warranty
support
• Faster response time, more uptime
• Secure access for troubleshooting
• Alarms & notifications, predictable maintenance
• Data logs to make more informed decisions faster
• Features scale to your business growth and customer
requirements, hardware costs are fixed
WebPort and WebPort CONNECTS……..
• Why WebPort and WP CONNECTS?
• Island of automation sales approach – OEM, SI, EU solution, (as
opposed to an enterprise solution)
• A business decision – how do you want to grow your business? Set
yourself apart from your competition
• Scalable – feature set complete, set up those feature sets you need,
when you need them, fixed cost
• Firmware upgradable in the field, ideal for future growth, hardware stays
relevant - i.e. 1:1 NAT routing……
• WebPort CONNECTS - Mitigate risk by utilizing on-board VPN
technology, Microsoft Azure Platform
• Total cost of ownership – ROI during warranty will overcome increase in
BOM costs
WebPort and WebPort CONNECTS……..
Feature Overview
• Firmware upgradable in the field
• NAT 1:1 functionality
• Class 1, Div 2, UL 508 Industrial certified
• Secure remote access (VPN service from Spectrum
Controls WebPort CONNECTS) to controllers / PLCs,
outbound connection Port 80 or 443
• Two part numbers; Ethernet or Ethernet +3G cell modem
access (antenna kit and data plan required for cell
modem)
WebPort and WebPort CONNECTS……..
• Alarms & notifications (analog, Boolean, and complex
alarming capabilities)
• Data logging and reporting (Cloud storage via Microsoft
Azure)
• Document storage (service records, schematics, BOMs,
spec sheets, quick start guides etc.)
• Customizable dashboards and customizable reports
• User defined access and controls for multiple users
• SQL database / HTML5 development
What additional Questions can I answer?
WebPort and WebPort CONNECTS……..
Wrapping up……….
Thank YOU!
• Elliot Fixler
– Northeastern Regional Manager
– Cell phone # 603-770-1197
– Office phone # 425-746-9481
– www.spectrumcontrols.com