48
Productcatalog Safety

Productcatalog - Magnum€¦ · 125012 1200 Watt 40 meter 10 meter 230V 5,2 44,1 125019 1900 Watt 63,3 meter 10 meter 230V 8,3 27,8 125034 3400 Watt 113,3 meter 10 meter 230V 14,8

  • Upload
    others

  • View
    20

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Productcatalog - Magnum€¦ · 125012 1200 Watt 40 meter 10 meter 230V 5,2 44,1 125019 1900 Watt 63,3 meter 10 meter 230V 8,3 27,8 125034 3400 Watt 113,3 meter 10 meter 230V 14,8

1

ProductcatalogSafety

Page 2: Productcatalog - Magnum€¦ · 125012 1200 Watt 40 meter 10 meter 230V 5,2 44,1 125019 1900 Watt 63,3 meter 10 meter 230V 8,3 27,8 125034 3400 Watt 113,3 meter 10 meter 230V 14,8

2

We are proud of our company and theproducts we deliver. This allows us to remainsteady as a strong and healthy organizationin price and service. Because of our owninvestments in the production, we canconstantly monitor the quality of ourproducts.

We always respond to the market demand.We follow social trends. This also includeslistening to the needs of our customers. Wefilter the key market developments as earlyas possible.

MAGNUM HeatingC&F Technics B.V.Slabbecoornweg 41NL - 4691 RZ Tholen

T +31(0)166 - 609 300F +31(0)166 - 604 877E [email protected] magnumheating.nl

Contact

© MAGNUM Heating B.V. | 2016 This edition replaces all previous editions. These conditions apply to all our agreements, sales and deliveries.No rights may be derived from the contents of this brochure. No part of this publication may be duplicated and published without the permission of MAGNUM Heating B.V.

We focus on improving our core products.We continue to invest in it. Just like we dowith our customers. Loyalty and searchingtogether for market opportunities are avery important part. Over the years we havebuilt up considerable expertise in specialistmarkets.

MAGNUM Heating offers heating solutions for comfort and safety, including the controlsystems to manage them interactive. We provide warmth and security using electric andwater technologies. Our products are made with quality materials for competitive prices. Thereal difference is for us the way we do business, service orientated and believing in long-termpartnership.

With the current structural developments, consumers are more interested in a comfortable and healthy living environment. The heating of MAGNUM provides for all these needs an ideal and affordable solutions.

Reliability Distinctive Focus through vision

Page 3: Productcatalog - Magnum€¦ · 125012 1200 Watt 40 meter 10 meter 230V 5,2 44,1 125019 1900 Watt 63,3 meter 10 meter 230V 8,3 27,8 125034 3400 Watt 113,3 meter 10 meter 230V 14,8

3

The company 2Technology 4Applications 6Benefits 8Projects 10References 12

Rampheating 14Outdoor Cable 16Outdoor Mat 18Outdoor Control 20

Electric Tracing 22Ideal Frost free ribbon 24Trace Regular 26Trace Micro 28Trace Micro Plug & Go 30Trace Gutter Heat 32Trace Gutter Heat KIT 34Trace Water 36Trace Hot Water 38Thermostats 40Sensors 41Connection material 42Mounting systems 44

Index

Page 4: Productcatalog - Magnum€¦ · 125012 1200 Watt 40 meter 10 meter 230V 5,2 44,1 125019 1900 Watt 63,3 meter 10 meter 230V 8,3 27,8 125034 3400 Watt 113,3 meter 10 meter 230V 14,8

4

Thermal or infra-red energy is light that isinvisible because the wave length is toolong for the human eye and forms thepart of the electromagnet spectrum thatwe experience as heat. Contrary to visiblelight, everything with a temperature aboveabsolute zero radiates heat in the infra-redworld. This is the source of our heat.

Infra-red energyInfra-red heating or radiated heat works justlike nature: Each day heat waves originatingfrom the sun reach the walls of your housefor example. The walls in turn store theheat that is then very slowly released. In theevening the ambient air cools down but youcan still feel the heat coming from the walls.A hot stone massage for example, works onthe same principle.

Infra-red energy

MAGNUM Outdoor offer safety and reliability with a low running cost and no maintenance. Safety prevention and continuity are key concepts that warrant the installation of frost free fittings. Suitable areas for this type of system are entrance and exit slopes of distribution centres, parking areas, hospitals, fire stations, office buildings or any area that during winter time could create a hazard or disruption.

The extensive concept of heat cables, sensors and regulating units create a compliant reaction to extreme weather in the variable European climates. Great temperature shifts and unexpected snow or hail: with a MAGNUM Outdoor system there is always safe and certain access!

Ramp heating

Page 5: Productcatalog - Magnum€¦ · 125012 1200 Watt 40 meter 10 meter 230V 5,2 44,1 125019 1900 Watt 63,3 meter 10 meter 230V 8,3 27,8 125034 3400 Watt 113,3 meter 10 meter 230V 14,8

5

cold pipe

less resistance

more heat

Warm pipe

more resistance

less heat

Electric Tracing is beside the frost protection also provided for a constant temperature (process temperature) like piping and vessels. MAGNUM self-regulating cables have two parallel metal wires which are encapsulated in a semi-conductive polymer PTC. When electric �ow is directed to the other copper wire through the conductive polymer, a closed circuit is established. Current heats the polymer and thereby increase the resistance

value. As the temperature increases from the conductive core, the electrical resistance decreases and consequently a decrease in temperature. This is done at any point along the pipe. This makes them energy e�cient and prevent overheating or combustion by overlap of the heating cables.

Electric Tracing

Technology

Page 6: Productcatalog - Magnum€¦ · 125012 1200 Watt 40 meter 10 meter 230V 5,2 44,1 125019 1900 Watt 63,3 meter 10 meter 230V 8,3 27,8 125034 3400 Watt 113,3 meter 10 meter 230V 14,8

6

Roofs

Stairs

Piping

Entrance pathsLoading ramps

Drainpipes

Applications

Page 7: Productcatalog - Magnum€¦ · 125012 1200 Watt 40 meter 10 meter 230V 5,2 44,1 125019 1900 Watt 63,3 meter 10 meter 230V 8,3 27,8 125034 3400 Watt 113,3 meter 10 meter 230V 14,8

7

Water pipes Olive treeRoof gutters

SidewalkRamps

Page 8: Productcatalog - Magnum€¦ · 125012 1200 Watt 40 meter 10 meter 230V 5,2 44,1 125019 1900 Watt 63,3 meter 10 meter 230V 8,3 27,8 125034 3400 Watt 113,3 meter 10 meter 230V 14,8

8

Advantages

Thanks to the highly precise digital controlgiven by the advanced clock thermostatsthat can be operated very simply for makingyour preferred settings, optimal comfort anda perfect living climate can be enjoyed byeverybody. Furthermore, MAGNUM heatingsystems can be very easily linked into newand existing domotic systems so that youhaving nothing more to bother about.

Energie-efficiënt

Whether you go for MAGNUM floor,wall or ceiling heating, our systems areextremely energy efficient thanks to thehighly accurate controls In additional theyare completely silent and there are nomaintenance costs. MAGNUM products areproduced under very strict conditions byourselves. They comply with the strictestEuropean inspection requirements andtherefore have a very long life-cycle.

Maintenance free

Page 9: Productcatalog - Magnum€¦ · 125012 1200 Watt 40 meter 10 meter 230V 5,2 44,1 125019 1900 Watt 63,3 meter 10 meter 230V 8,3 27,8 125034 3400 Watt 113,3 meter 10 meter 230V 14,8

9

Advantages

Combined with the accurate and efficientcontrol systems, direct heat emission, extralong life-cycle and the possibility to regulateeach room independently, electric heatingsystems provide the perfect heat source.This is certainly the case over the last fewyears during which the gas prices have risendramatically, resulting in electrically heatedrooms being equivalent to gas fired heatedrooms with respect to running costs.

Sustainable

Safety, prevention and continuity are key words that justify an investment for the installation of a frost-free installation. For small areas, such as wheel tracks or walking paths, which should be kept frost-free it provides MAGNUM Outdoor concept to safety and reliability at minimum investment, consumption and maintenance costs.

Safety first

Page 10: Productcatalog - Magnum€¦ · 125012 1200 Watt 40 meter 10 meter 230V 5,2 44,1 125019 1900 Watt 63,3 meter 10 meter 230V 8,3 27,8 125034 3400 Watt 113,3 meter 10 meter 230V 14,8

10

In principle, the standard programme offerssufficient possibilities to meet virtuallyevery type of situation. Experience tells usthat ready-made solutions are not alwayssuitable. In such circumstances we canfind a custom designed and manufacturedsolution.

Custom Made

Projects

The wide range of heating systems andcontrol mechanisms gives MAGNUM thepossibility to reach or develop solutions forevery type of heating problem. The deliveryand installation of tracing, insulation, supplycables and switchboards, as well as testingand supplying the installation work, are allpossible.

Full Service

Page 11: Productcatalog - Magnum€¦ · 125012 1200 Watt 40 meter 10 meter 230V 5,2 44,1 125019 1900 Watt 63,3 meter 10 meter 230V 8,3 27,8 125034 3400 Watt 113,3 meter 10 meter 230V 14,8

11

We only want to supply top quality products,therefore all MAGNUM products areproduced and tested to the ISO 9001: 2008standard by the largest European testingbodies. Our products therefore comply withthe highest testing requirements allowing usto offer you excellent guarantee conditions.

Tests

MAGNUM Calculation provides advice,engineering, calculations, offers, support,service and after-sales service. It mayconcern a simple access ramp, or a verycomplex control system for a large project,or the engineering for an entire plantwith tracing, including circuit layout andAutoCAD drawings.

Calculation

Our help-desk id your contact point forall your enquiries as well as the morecomplex issues including: heat losscalculations, special requirements suchas stabilising or heating pipes, managingcritical temperatures and the application ofdiffering supply voltages can all be provided.

Helpdesk

You can always get help and advice from ourexpert consultants for analysing problemsand coming up with innovative solutionsfor your project. We are happy to collaboratewith you in meeting challenges and to shareour knowledge and experience.

Advice

ISO-9001:2008

Page 12: Productcatalog - Magnum€¦ · 125012 1200 Watt 40 meter 10 meter 230V 5,2 44,1 125019 1900 Watt 63,3 meter 10 meter 230V 8,3 27,8 125034 3400 Watt 113,3 meter 10 meter 230V 14,8

12

Friesland Campina | EdeRoof heating1275 m2 MAGNUM Outdoor Cable

Centraal Station | TilburgEntrance stairs (prefab)460 m2 MAGNUM Outdoor Cable

IKEA Concept Center | DelftRamp heating 2200 m2 MAGNUM Outdoor Cable

Audi Munstadt | ZeistRamp heating500 m2 MAGNUM Outdoor Cable

Groot Baronie | Alphen aan den RijnRamp heating830 m2 MAGNUM Outdoor Cable

Lidl | LandelijkFrost free storage cell floorsCustom made heating cable

Burgers Zoo | ArnhemSnow and ice melting on paths500 m2 MAGNUM Outdoor Mat

Reststoffenenergiecentrale | Harlingen Ramp heating 680 m2 MAGNUM Outdoor Cable

Ziggo Dome | AmsterdamEntrance and exit ramp parking125 m2 MAGNUM Outdoor Cable

Page 13: Productcatalog - Magnum€¦ · 125012 1200 Watt 40 meter 10 meter 230V 5,2 44,1 125019 1900 Watt 63,3 meter 10 meter 230V 8,3 27,8 125034 3400 Watt 113,3 meter 10 meter 230V 14,8

13

ReferencesA selection of some of the many projects in whichMAGNUM Outdoor products have been installed

Albert Heijn XL | HeemstedeFrost protection sprinkler garage225 meter MAGNUM Trace Micro

Schipholtunnel | HaarlemmermeerFrost protection water drain600 meter MAGNUM Trace Gutter Heat

Montevideo | RotterdamFrost protection600 meter MAGNUM Trace Regular

Page 14: Productcatalog - Magnum€¦ · 125012 1200 Watt 40 meter 10 meter 230V 5,2 44,1 125019 1900 Watt 63,3 meter 10 meter 230V 8,3 27,8 125034 3400 Watt 113,3 meter 10 meter 230V 14,8

14

Ramp heating

Page 15: Productcatalog - Magnum€¦ · 125012 1200 Watt 40 meter 10 meter 230V 5,2 44,1 125019 1900 Watt 63,3 meter 10 meter 230V 8,3 27,8 125034 3400 Watt 113,3 meter 10 meter 230V 14,8

15

Ramp heating

• Entrances and exits• Parkings• Loading ramps• Trappen• Helicopter platforms• Bridges• Entrances• Sidewalks Etc.

ApplicationsThere are within this category 3 products available:

• MAGNUM Outdoor Cable• MAGNUM Outdoor Mat• MAGNUM Outdoor Control

Products

Especially for large areas like loading docks or ramps for parking garages, where safety must be guaranteed. MAGNUM Outdoor Cable can be attached directly to the reinforcement before the concrete is poured.

Outdoor Cable

This mat is especially designed to heat trails and tracks. The heating mat is easy to roll out, to cut and to store for quick and easy installation.

Outdoor Mat

Here you will �nd switch cabinets (custom-made), thermostats and sensors for optimum control of your Outdoor Cable or Mat system. The advanced sensors measure temperature combined with humidity so the thermostat can accurately determine whether the system should be enabled.

Outdoor Control

Page 16: Productcatalog - Magnum€¦ · 125012 1200 Watt 40 meter 10 meter 230V 5,2 44,1 125019 1900 Watt 63,3 meter 10 meter 230V 8,3 27,8 125034 3400 Watt 113,3 meter 10 meter 230V 14,8

16

Especially for larger surfaces, such as loading docks or entrance and exit ramps for parking garages, where safety needs to be guaranteed. The MAGNUM Outdoor Cable can be secured directly onto the reinforcement steel before the sand bed, concrete or asphalt is poured. MAGNUM Outdoor is a highly advanced system of heatingcables, 2 sensor units that measure moisture in combination with the outside temperature, and a custom-made control box. The power cord is connected to the resistance wire with anelectric welding. The aluminium casing protects the resistance wire against mechanical damage and shields the cable against EMC (electromagnetic radiation). The advantage of this isthat the cable will not cause interference on mobile phones, electric garage doors and gateways, security installations etc. The cable is equipped with PTFE (Teflon) inner jackets and aPVC outer jacket which is resistant against the influence of chemicals.

MAGNUM Outdoor Cable

Installation in concrete

Stairs

Entrance path

Unique blind connection!

Quick.Easy.Secure!

Page 17: Productcatalog - Magnum€¦ · 125012 1200 Watt 40 meter 10 meter 230V 5,2 44,1 125019 1900 Watt 63,3 meter 10 meter 230V 8,3 27,8 125034 3400 Watt 113,3 meter 10 meter 230V 14,8

17

Complete systemsMAGNUM Outdoor installations are specially drawn and designed per case. A full watertight switchboard (IP-65) is made and installed to the ratio of the number of cables/mats and power capacity. For bigger works, the switchboard can be extended with modulating power regulators up to 50kW, that avoid peak load and besides also save energy. The system can be implemented in 230V as well as in 400V.

Technical speci�cations• Power capacity 600/1200/1900 & 3400 Watt• Connection voltage: 230 V/50Hz• IEC 800 and CE norms• ISO 9001 produced• IPX7• PTFE ( Te�on) core insulation• Suitable for poured asphalt up to 240ºC

Waranty10 year warranty on the electrical activity of the cable.

Part.no. Capacity Length Length connecting wire Voltage Amperes Ohms

125006 600 Watt 20 meter 10 meter 230V 2,6 88,2

125012 1200 Watt 40 meter 10 meter 230V 5,2 44,1

125019 1900 Watt 63,3 meter 10 meter 230V 8,3 27,8

125034 3400 Watt 113,3 meter 10 meter 230V 14,8 15,6

Technical details

Installation under pavers

30W/m1

230V

Installation in asphalt

10 YEARWARRANTY

Page 18: Productcatalog - Magnum€¦ · 125012 1200 Watt 40 meter 10 meter 230V 5,2 44,1 125019 1900 Watt 63,3 meter 10 meter 230V 8,3 27,8 125034 3400 Watt 113,3 meter 10 meter 230V 14,8

18

This mat has been designed specifically to heat walkways and driving tracks. The heating mat is easy to roll out, can be cut and can be folded for easy and quick installation. MAGNUM Outdoor Mat is a highly advanced system of heatingmats, 2 sensor units that measure moisture in combinationwith the outside temperature, and a custom-made control box. The power cord is connected to the resistance wire with anelectric welding. The aluminium casing protects the resistance wire against mechanical damage and shields the cable against EMC (electromagnetic radiation). The advantage of this isthat the cable will not cause interference on mobile phones, electric garage doors and gateways, security installations etc. The cable is equipped with PTFE (Teflon) inner jackets and a PVC outer jacket which is resistant against the influence of chemicals.

MAGNUM Outdoor Mat

Installation under pavers

Unique blind connection!

Quick.Easy.Secure!

Page 19: Productcatalog - Magnum€¦ · 125012 1200 Watt 40 meter 10 meter 230V 5,2 44,1 125019 1900 Watt 63,3 meter 10 meter 230V 8,3 27,8 125034 3400 Watt 113,3 meter 10 meter 230V 14,8

19

Complete systemsMAGNUM Outdoor installations are specially drawn and designed per case. A full watertight switchboard (IP-65) is made and installed to the ratio of the number of cables/mats and power capacity. For bigger works, the switchboard can be extended with modulating power regulators up to 50kW, that avoid peak load and besides also save energy. The system can be implemented in 230V as well as in 400V.

Technical speci�cations• Dimensions 2, 5, 8 and 10 m2

• Power capacity 600, 1500, 2400 and 3000 watt• Connection voltage: 230 V/50Hz• IEC 800 and CE norms• ISO 9001 produced• IPX7• PTFE (Te�on) core insulation• Suitable for poured asphalt up to 240ºC

Warranty10 years warranty on the electromechanical operation of the cable.

Technical details300W/m2

230V

Installation in concrete

Installation in asphalt

Part.no. Dimensions Capacity Dimensions Voltage Amperes Ohms

126002 2 m2 600 Watt 0,5 x 4 meter 230V 2,6 88,2

126005 5 m2 1500 Watt 0,5 x 10 meter 230V 6,5 35,3

126008 8 m2 2400 Watt 0,5 x 16 meter 230V 10,4 22

126010 10 m2 3000 Watt 0,5 x 20 meter 230V 13 17,6

10 YEARWARRANTY

Page 20: Productcatalog - Magnum€¦ · 125012 1200 Watt 40 meter 10 meter 230V 5,2 44,1 125019 1900 Watt 63,3 meter 10 meter 230V 8,3 27,8 125034 3400 Watt 113,3 meter 10 meter 230V 14,8

20

MAGNUM Outdoor ControlFull watertight switchboards, made and installed to the ratio of the number of cables/mats and power capacity. For bigger works, the switchboard can be extended with modulating power regulators up to 50kW, that avoid peak load and besides also save energy. The system can be implemented in 230V as well as in 400V. Sensor units (ETOG-55)The sensor units are equipped with a heating element that melts snow or glazed frost. This means the system is only activated when the outside temperature is lower than the set value (p.e. +3°C) and the sensor unit detects moisture at the same time. This method guarantees energy-efficient control. MAGNUM Outdoor Control is supplied including an ETO-4550 Din-rail thermostat and 2 ETOG-55 sensors.

Warranty10 year warranty for electro technical function.

Installatie met ETOG-56 Sensorunit

Page 21: Productcatalog - Magnum€¦ · 125012 1200 Watt 40 meter 10 meter 230V 5,2 44,1 125019 1900 Watt 63,3 meter 10 meter 230V 8,3 27,8 125034 3400 Watt 113,3 meter 10 meter 230V 14,8

21

Part.no. Switch panels

900004 3,6 kW incl. ETO2-4550 DIN-rail thermostat and 2x ETOG-56 Sensorunits

900010 10 kW incl. ETO2-4550 DIN-rail thermostat and 2x ETOG-56 Sensorunits

900020 20 kW incl. ETO2-4550 DIN-rail thermostat and 2x ETOG-56 Sensorunits

900030 30 kW incl. ETO2-4550 DIN-rail thermostat and 2x ETOG-56 Sensorunits

900040 40 kW incl. ETO2-4550 DIN-rail thermostat and 2x ETOG-56 Sensorunits

900050 50 kW incl. ETO2-4550 DIN-rail thermostat and 2x ETOG-56 Sensorunits

Part.no. Thermostats

893550 ETO2-4550 DIN-rail thermostat temp./moisture 3x16A 230V

900056 ETR-2 DIN-rail thermostaat temp./moisture 1x16A 230V

892551 ETN-4 Digital DIN-rail thermostat -20/+70oC 16A 230 V

Part.no. Sensors890065 ETOG-56 Sensorunit temp./moisture for ramp

900055 ETOR-55 Sensorunit moisture for roof gutter

901441 ETF-744/99 Extern outdoor temperaturesensor

ETOG-56 Sensorunit (Moisture & Temp.)

This all in 1 sensor registers temperature as well as moisture. The built-in heating element takes care of highly accurate control.

Connection box watertight (IP-65 conform NEN 1010)Fully pre-assembled at delivery, including: • ETO-4550 DIN-rail thermostat 0/+5ºC 230V• 2x ETOG-55 Sensor units (Moisture & Temp.)• Potential free contacts 3x16 Amperes• Needed magnet switches (relay) 230V/400V• Needed circuit breakers 16 Amperes• Connecting terminals for mounting power supply cables• Indicator lights

Technical details

ETOR-55 Sensorunit (Moisture)

This moisture sensor is designed especially for installation in gutters and drains. Can only be used in combination with outdoor sensor type ETF-744/99.

ETF-744/99 Sensorunit (Temp.)

This outdoor sensor registers only the temperature. Can be used for temperature detection only, or in combination with outdoor sensor type ETOR-55.

ETO2-4550 DIN-rail thermostat

An intelligent all-in-one solution for melting snow and ice. Optimal operation is guaranteed by a power capacity regulator.

ETR-2 DIN-rail thermostat

The ETR-2 gives an economical control for melting snow and ice in smaller applications. With a focus on energy use and simple installation.

ETN-4 DIN-rail thermostat

An all-in-one thermostat with extensive temperature regulation, suitable for a wide range of applications. Simple to operate and program.

2 YEARWARRANTY

Page 22: Productcatalog - Magnum€¦ · 125012 1200 Watt 40 meter 10 meter 230V 5,2 44,1 125019 1900 Watt 63,3 meter 10 meter 230V 8,3 27,8 125034 3400 Watt 113,3 meter 10 meter 230V 14,8

22

Elec

tric T

raci

ng

Within this category 7 products are available:• Ideal frost free ribbon• Trace Regular• Trace Micro• Trace Micro Plug & Go• Trace Gutter Heat• Trace Water• Trace Hot Water

ProductsMAGNUM Trace systems canbe applied to:• Cold and hot water pipes• Roof gutters• Downpipes• Drains• Sprinkler systems• Oil pipelines• Process Piping (food)

Applications

Page 23: Productcatalog - Magnum€¦ · 125012 1200 Watt 40 meter 10 meter 230V 5,2 44,1 125019 1900 Watt 63,3 meter 10 meter 230V 8,3 27,8 125034 3400 Watt 113,3 meter 10 meter 230V 14,8

23

Various connection and fastening materials for the MAGNUM Tracing program.

Connecting materialsFrom simple to fully automatic circuit temperature combined with humidity.

Thermostats & Sensors

Ready to plug in and specially designed for keeping piping, taps, discharge pipes (not plastic) from freezing.

Ideal Frost Free Ribbon

Unlike regular heating cables, MAGNUM Tracing cables are equipped with parallel circuits. This means you can cut the cable at any point without breaking the circuit. Thanks to this parallel circuit, these cables are very easy to install. They can be installed in a linear way, in spiral shape or with overlap.

During the installation, you can simply cut them in the right size, lengthen them or split them according to your needs. There are various connection possibilities. For example, a pre-assembled cable is available in various lengths, with quick coupling pieces in order to complete tasks quickly. Because

the MAGNUM Tracing cables do not require thermostatic control, they are not subject to malfunctions. MAGNUM Tracing cables can be used on plastic as well as metal piping.

Eenvoudige installatie

Self-regulating cable available in 10, 15, 25 and 33 watts per meter.

Trace RegularSelf-regulating cable for pipes with a small diameter.

Trace Micro

Trace Micro cable with connectors and cable.

Trace Micro Plug & GoFor protection of your gutter and drainpipe against freezing.

Trace Gutter HeatSelf-regulating cable suitable for installation in a water pipe.

Trace Water

To compensate for heat loss in hot water systems.

Trace Hot Water

Page 24: Productcatalog - Magnum€¦ · 125012 1200 Watt 40 meter 10 meter 230V 5,2 44,1 125019 1900 Watt 63,3 meter 10 meter 230V 8,3 27,8 125034 3400 Watt 113,3 meter 10 meter 230V 14,8

24

MAGNUM Ideal Frost Free Ribbon

In many situations outdoor taps and pipes must be shut off in winter in order to avoid becoming frozen. MAGNUM offers a much simpler solution: MAGNUM Ideal frost free ribbon means that frozen and leaking pipes are a thing of the past! The MAGNUM Ideal frost free ribbon delivery programme has been specially designed for keeping piping, taps, discharge pipes (not plastic) from freezing. The problems with freezing can very simply be avoided by fitting the Ideal band along the piping - it is ready to plug in and fitted with an automatic thermostat. Once the pipe insulation has been applied, it is not only safe, but extra expenses for repairing water pipes and also damage from leaking pipes is avoided. MAGNUM Ideal frost free ribbon (with a 2 meter connecting cable with earthed plug) comes complete with a bi-metal temperature regulator. MAGNUM Ideal frost free ribbon is available in lengths of 1 to 48 meters. The heating band is switched on at temperatures below +5°C and automatically switches off when the temperature exceeds +13°C.

Page 25: Productcatalog - Magnum€¦ · 125012 1200 Watt 40 meter 10 meter 230V 5,2 44,1 125019 1900 Watt 63,3 meter 10 meter 230V 8,3 27,8 125034 3400 Watt 113,3 meter 10 meter 230V 14,8

25

Part.no. Length Capacity Volt

155001 1 metre 10 Watt 230V

155002 2 metre 20 Watt 230V

155004 4 metre 40 Watt 230V

155006 6 metre 60 Watt 230V

155008 8 metre 80 Watt 230V

155010 10 metre 100 Watt 230V

155014 14 metre 140 Watt 230V

155018 18 metre 180 Watt 230V

155022 22 metre 220 Watt 230V

155026 26 metre 260 Watt 230V

155030 30 metre 300 Watt 230V

155034 34 metre 340 Watt 230V

155040 40 metre 400 Watt 230V

155048 48 metre 480 Watt 230V

Technical details

MAGNUM Ideal can very easily be applied to metal piping (not plastic) using aluminium tape or plastic tie-wraps. MAGNUM Ideal should always be used in combination with a (polyethylene) pipe insulation that has a minimum thickness of 10 mm. This gives optimal protection and insulation, thereby warranting energy-e�cient operation.

MAGNUM Ideal is supplied as standard with the following• Heating cable, complete with plug and 2 meter of connecting cable• Integral bi-metal thermostat• Installation instructions• PVC tape

Technical detailsCapacity 10 watt per meter length / 230 VoltConnecting cable 2 meters with earthed plugClass IPX7

Warranty2 years on the electromechanical operation of the cable

Max. diameter pipe 15mm 20mm 25mm 30mm 40mm 50mm 100mm

Method of application Protection of water supply:

Linear (along tube) -30 oC -30 oC -25 oC -20 oC -15 oC -10 oC -5 oC

10 windings per m -- -- -30 oC -30 oC -25 oC -25 ºC -20 oC

20 windings per m -- -- -- -- -30 oC -30 oC -30 oC

Calculate the cable Length pipe:

10 windings per m (x) 1,25 1,50 1,75 2 2,25 2,5 4

20 windings per m. (x) 2 2,25 2,50 2,75 3,25 4 8

Calculate the required cable length:

10W/m1

230V

Page 26: Productcatalog - Magnum€¦ · 125012 1200 Watt 40 meter 10 meter 230V 5,2 44,1 125019 1900 Watt 63,3 meter 10 meter 230V 8,3 27,8 125034 3400 Watt 113,3 meter 10 meter 230V 14,8

26

Self-regulating heating tape <85 ° C MAGNUM Trace Regular - MTR is an industrial grade self-regulating heating tape that can be used for freeze protection or temperature maintenance of pipework and vessels up to85°C. For use in non-hazardous, hazardous and corrosive areas. It can be cut-to-length on-site to match exact piping lengths without any complicated design considerations. Its self-regulating characteristics improve safety and reliability. This MTR will not overheat or burn, even when overlapping upon itself. It’s power output self-regulates in response to the pipe temperature. MTR is available with a corrosion resistant thermoplastic outer jacket.

Applications• Cold water pipes• Drains• Sprinkler systems• Oil pipelines

Additional informationThe extent of the loss of heat depends on the diameter of the piping, the ambient temperature and the flow of liquid Extra insulation is advised. Use of a temperature regulator reduces energy consumption. For calculating the heat loss and the applicable cable, you cancontact the sales department of MAGNUM Heating.

MAGNUM Trace Regular

25

50

45

40

35

30

Temperature (oC)

Nor

mal

(W

/M)

Temperature graph ( DECKER )

0 10 20 30 40W/℃

20

15

10

5

-20 -10

33W

25W

15W

10W

Page 27: Productcatalog - Magnum€¦ · 125012 1200 Watt 40 meter 10 meter 230V 5,2 44,1 125019 1900 Watt 63,3 meter 10 meter 230V 8,3 27,8 125034 3400 Watt 113,3 meter 10 meter 230V 14,8

27

Maximum temperature Without power 85°C / With power 65°CMinimum operating temperature -30°CMaximum resistance 18,2 Ohm/kmVoltage 230 V (115 V at request)Outer jacket Tinned copperCoating Fluor polymer (optional)Water resistant 100%Dimensions 13 x 6,8 mmMinimum bending radius 25 mmWeight 12 kg/100 mT-Rating 10, 15, 25 W/m T6T-Rating 33 W/m T5Color GreyInspections 10 mtr & 15 mtr: CE /RU 15 mtr & 33 mtr: CE / RU / FM / EX according to DIN EN 62395-1

Maximum advised cable length at 230V with use of Type-C relay:Category Switch 230VReference Temp. 16A 20A 30A10MT +10°C 205 m - - -15°C 140 m 186 m 195 m -25°C 123 m 165 m 195 m 15MT +10°C 145 m 162 m - -15°C 93 m 125 m 160 m -25°C 82 m 111 m 160 m 25MT +10°C 88 m 117 m 126 m -15°C 60 m 75 m 117 m -25°C 50 m 70 m 105 m 33MT +10°C 70 m 90 m 108 m -15°C 50 m 65 m 95 m -25°C 45 m 58 m 85 m

WARNING: Heating cables in combination with drinking water pipes must be controlled at all times thermostatically.

Part.no. Type Capacity Voltage Rating

151010 MTR-10 10 Watt @ 10°C 230V

151015 MTR-15 15 Watt @ 10°C 230V

151025 MTR-25 25 Watt @ 10°C 230V

151033 MTR-33 33 Watt @ 10°C 230V

Options

pag. 40-45

Technical details

1.2 mm2 tinned copper wire

self-limiting heating

protective insulation

TPE insulation

earthed braid

TPE sheath

2 YEARWARRANTY

Page 28: Productcatalog - Magnum€¦ · 125012 1200 Watt 40 meter 10 meter 230V 5,2 44,1 125019 1900 Watt 63,3 meter 10 meter 230V 8,3 27,8 125034 3400 Watt 113,3 meter 10 meter 230V 14,8

28

MAGNUM Trace Micro - MTM is an industrial grade self-regulating heating tape that can be used for frost protection or maintaining the temperature of pipework and vessels. It is especially suitable for use on pipes and instruments with small diameters. It can be cut to length at site to match exact piping lengths without any complicated design considerations. Its self-regulating characteristics improve safety and reliability. This MTM will not overheat or burn, even when overlapped upon itself. Its power output self-regulates in response to the pipe temperature. MTM is available with a corrosion resistant thermoplastic outer jacket; and with a fluorine polymer outer jacket (MTM-Fluorine polymer) in cases when greater corrosion resistance is required.

Applications• Cold water pipes• Drains• Sprinkler systems• Oil pipelines (MTM-Fluorine polymer)

Additional informationThe extent of the loss of heat depends on the diameter of the piping, the ambient temperature and the flow of liquid. Extra insulation is advised. Use of a temperature regulator reduces energy consumption. For calculating the heat loss and the applicable cable, you cancontact the sales department of MAGNUM Heating.

MAGNUM Trace Micro

25

50

45

40

35

30

Temperature (oC)

Nor

mal

(W

/M)

Temperature graph ( SMALL )

0 10 20 30 40W/℃

20

15

10

5

-20 -10

17W

11W

Fluorpolymer

Page 29: Productcatalog - Magnum€¦ · 125012 1200 Watt 40 meter 10 meter 230V 5,2 44,1 125019 1900 Watt 63,3 meter 10 meter 230V 8,3 27,8 125034 3400 Watt 113,3 meter 10 meter 230V 14,8

29

Maximum temperature 65°CMinimum werk temperature -30°CMaximum resistance 18 Ohm/kmVoltage 230 VOuter sheath Tinned copperCoating Thermoplastic or Fluor polymer watertightDImensions (mm) 8 x 5 mmMinimum bending radius 25 mmWeight 7 kg/100 mColor MTM 11 en 17 watt RedMTM- Fluorpolymer BlueTests CE /RU, According to DIN EN 62395-1

Maximum advised cable length at 230V with use of Type-C relay:

Category Switch Enable Relay Reference Temp. 6 Amp 10 Amp 16 Amp11MTM +5°C 70 m 100 m 110 m 0°C 65 m 95 m 105 m -20°C 44 m 77 m 90 m -30°C 38 m 67 m 80 m 17MTM +5°C 39 m 60 m 70 m 0°C 37 m 58 m 65 m -20°C 25 m 44 m 50 m -30°C 23 m 41 m 47 m

WARNING: Heating cables in combination with drinking water pipes must be controlled at all times thermostatically.

Technical details

1.2 mm2 tinned copper wire

self-limiting heating

  TPE insulation

earthed braid

TPE or �uoropolymer sheath

Part.no. Type Length Capacity Voltage

150211 MTM-11 Per meter 11 Watt @ 10°C 230V

150411 MTM-11 Rol 25 meter 11 Watt @ 10°C 230V

150511 MTM-11 Rol 50 meter 11 Watt @ 10°C 230V

150611 MTM-11 Rol 100 meter 11 Watt @ 10°C 230V

150217 MTM-17 per meter 17 Watt @ 10°C 230V

150417 MTM-17 Rol 25 meter 17 Watt @ 10°C 230V

150517 MTM-17 Rol 50 meter 17 Watt @ 10°C 230V

150617 MTM-17 Rol 100 meter 17 Watt @ 10°C 230V

Type of Fluorine polymer

150311 MTM-11 Fluorpolymeer Per meter 11 Watt @ 10°C 230V

150317 MTM-17 Fluorpolymeer Per meter 17 Watt @ 10°C 230V

Options

pag. 40-45

2 YEARWARRANTY

Page 30: Productcatalog - Magnum€¦ · 125012 1200 Watt 40 meter 10 meter 230V 5,2 44,1 125019 1900 Watt 63,3 meter 10 meter 230V 8,3 27,8 125034 3400 Watt 113,3 meter 10 meter 230V 14,8

30

MAGNUM Trace Plug & GoMAGNUM Trace Micro Plug & Go is an industrial grade self-regulating heating ribbon that can be used for frost protection or to maintain the temperature of pipework and vessels up to 65°C. Suitable for use in non-hazardous, hazardous and corrosive areas. The self-regulating characteristic of MAGNUM Tracing cables avoids overheating or burning, even when heating cables overlap. The power capacity regulates itself in response to the temperature of the pipe. The conductive polymer core transmits the required heat automatically at each point along the pipe without using a thermostat.

Applications• Cold water pipes• Drains• Sprinkler systems

Additional informationThe extent of the loss of heat depends on the diameter of the piping, the ambient temperature and the flow of liquid. Extra insulation is advised. Use of a temperature regulator reduces energy consumption. For calculating the heat loss and the applicable cable, you cancontact the sales department of MAGNUM Heating.

Page 31: Productcatalog - Magnum€¦ · 125012 1200 Watt 40 meter 10 meter 230V 5,2 44,1 125019 1900 Watt 63,3 meter 10 meter 230V 8,3 27,8 125034 3400 Watt 113,3 meter 10 meter 230V 14,8

31

Technical details

Technical details cableSee MAGNUM Trace Micro.

MAGNUM Trace Micro Plug & Go- Ready-to-install heating elements including connectors- Power capacity 11W/meter @ 10°C 230V- IP67 connection

Connection cable- Earthed connection cable- Including connector and end cap- Available with or without thermostat- Thermostat enabled at < 5°C

Maximum advised cable length at 230V with use of Type-C relay:

Category Switch On power relay Reference Temp. 6 Amp 10 Amp 16 Amp 11MTM +5°C 70 m 100 m 110 m 0°C 65 m 95 m 105 m -20°C 44 m 77 m 90 m -30°C 38 m 67 m 80 m

WARNING: Heating cables in combination with drinking water pipes must be controlled at all times thermostatically.

1.2 mm2 tinned copper wire

self-limiting heating

  TPE insulation

earthed braid

TPE sheath

Part.no. Type Length Capacity Voltage

159711 MTM-PG 1 1 meter 11 Watt @ 10°C 230V

159703 MTM-PG 3 3 meter 33 Watt @ 10°C 230V

159705 MTM-PG 5 5 meter 55 Watt @ 10°C 230V

159709 MTM-PG 9 9 meter 99 Watt @ 10°C 230V

159715 MTM-PG 15 15 meter 165 Watt @ 10°C 230V

159722 MTM-PG 22 22 meter 242 Watt @ 10°C 230V

Options

159701 Cable 2m without thermostat incl. Connector endcap

159702 Cable 2m with thermostat incl. Connector endcap. switch temperature: <5 ° C

pag. 40-45

IP672 YEARWARRANTY

Page 32: Productcatalog - Magnum€¦ · 125012 1200 Watt 40 meter 10 meter 230V 5,2 44,1 125019 1900 Watt 63,3 meter 10 meter 230V 8,3 27,8 125034 3400 Watt 113,3 meter 10 meter 230V 14,8

32

MAGNUM Trace Gutter HeatSelf-regulating heating ribbon for eaves < 85°C

MAGNUM Trace Gutter Heat (MTGH) is a self-regulating heating cable specifically designed to prevent snow and ice building up on roofs, in eaves and in drainpipes. In snow and icy water the cable operates at full power. As the snow melts and the water drains away MTGH self regulates to half power while it dries; as it gets warmer it gradually reduces its output. It can be cut-to-length during installation. The MTGH is a self-regulation cable and therefore prevents overheating. It can even be installed directly into plastic gutters and with a black, corrosion stable and UV stable outer jackets the system is durable and reliable. The installation of MTGH is quick and simple and requires no special skills or tools. Termination, splicing and connection components are available.

Additional information• It is recommended that an additional temperature controller is used. A controller that measures the ambient temperature and the presence of snow or moisture is the most efficient.• This cable should not be placed on Bitumen surfaces.

MAGNUM Trace Gutter Heat KitReady to use heating elements with built-in thermostat. Easy to use and installed directly. Equipped with a thermostat that switches on below 5°C and switches off below -10°C.• Including a 3 meter connection cable• Securing clips• IP67 protected

For calculating the heat loss and the applicable cable, you cancontact the sales department of MAGNUM Heating.

A - In snow and ice water the boiler will operate at full power.B - As the snow melts, the capacity drops automatically.C - The capacity decreases further to all the snow and ice is gone.

Page 33: Productcatalog - Magnum€¦ · 125012 1200 Watt 40 meter 10 meter 230V 5,2 44,1 125019 1900 Watt 63,3 meter 10 meter 230V 8,3 27,8 125034 3400 Watt 113,3 meter 10 meter 230V 14,8

33

Structure Aluminium foil with UV-resistant TPE-O sheathBus leads Nickel plated copper wirePower output Air at 10 °C - 20 W / Ice at 30 WMaximum temperature Without power 85°C / With power 65°CVoltage 230 VMinimum bending radius 25 mmLowest installation temperature -45°CDimensions (mm) 10.5 x 5.9Weight 7,4 kg/100 mColor Black/UV stable

Maximum length (m) vs. scale circuit break:

Category Switch- 230Vreference temp. 6A 16A 20AMTGH-20 10°C 44 72 80 0°C 36 58 80

Part.no. Type Capacity Voltage

151020 MTGH-20 20 Watt @ 10°C 230V

Options

pag. 40-45

Technical details

1.2 mm2 tinned copper wire

self-limiting heating

  protective insulation

TPE insulation

aluminum earth sheath with wire

TPE sheath

2 YEARWARRANTY

Page 34: Productcatalog - Magnum€¦ · 125012 1200 Watt 40 meter 10 meter 230V 5,2 44,1 125019 1900 Watt 63,3 meter 10 meter 230V 8,3 27,8 125034 3400 Watt 113,3 meter 10 meter 230V 14,8

34

MAGNUM Trace Gutter Heat KITZelfregelend verwarmingslint voor dakgoten < 85°C MAGNUM Trace Gutter Heat (MTGH-Kit) is een zelfregulerende verwarmingskabel die specifiek ontworpen is om sneeuw- en ijsvorming op daken, in dakgoten en regenpijpen te voorkomen. Zelfs in de sneeuw en in ijswater functioneert de kabel op vol vermogen. Als de sneeuw smelt en het water wegstroomt, reguleert de MTGH-Kit zichzelf naar half vermogen naarmate hij droger wordt; hoe warmer het wordt, hoe meer hij zijn afgifte verlaagt. Deze kabel kan tijdens de installatie op lengte gesneden worden. De MTGH-Kit is een zelfregulerende kabel, die oververhitting voorkomt. Deze kan zelfs direct in kunststof dakgoten worden geïnstalleerd en met zijn zwarte, roestvrije en UV-vaste buitenmantel is het systeem weerbaar en betrouwbaar.

De MTGH-Kit is snel en eenvoudig te installeren en u hebt hiervoor geen speciale vaardigheden of gereedschappen nodig.

Aanvullende informatie• Deze kabel mag niet op een bitumen ondergrond geplaatst worden.

Voor calculatie van een warmteverliesberekening en toe te passen kabel kunt u contact opnemen met de verkoopafdeling van MAGNUM Heating.

A - In sneeuw en ijswater zal de kabel op vol vermogen werken.B - Als de sneeuw smelt daalt het vermogen automatisch.

Page 35: Productcatalog - Magnum€¦ · 125012 1200 Watt 40 meter 10 meter 230V 5,2 44,1 125019 1900 Watt 63,3 meter 10 meter 230V 8,3 27,8 125034 3400 Watt 113,3 meter 10 meter 230V 14,8

35

See MAGNUM Trace Gutter Heat.

MTGH-KitKlaar voor gebruik verwarmingselementen met ingebouwde thermostaat. Gemakkelijk in gebruik en direct te installeren. Met ingebouwde thermostaat die inschakelt bij temperaturen onder 5°C en uitschakelt bij temperaturen onder -10°C en bij 13°C.

Geleverd als complete kit inclusief:- Incl. aansluitkabel van 3 meter- 2x Bi-metaal thermostaat- Bevestigingsclips (1 per meter lengte)- Metalen strips t.b.v. ondersteuning in regenpijp- Met IP67 bescherming

Art.Nr. Type Vermogen Nominale spanning

159605 MTGH-Kit 5 m 100 Watt @ 10°C 230V

159610 MTGH-Kit 10 m 200 Watt @ 10°C 230V

159615 MTGH-Kit 15 m 300 Watt @ 10°C 230V

159625 MTGH-Kit 25 m 500 Watt @ 10°C 230V

Opties

Zie pag. 40-45

Technical details

1,2 mm2 vertind koperen kabel

zelfbegrenzend verwarmingselement

beschermisolatie

TPE isolatie

aluminium aardmantel met draad

TPE beschermhuls

IP672 YEARWARRANTY

Page 36: Productcatalog - Magnum€¦ · 125012 1200 Watt 40 meter 10 meter 230V 5,2 44,1 125019 1900 Watt 63,3 meter 10 meter 230V 8,3 27,8 125034 3400 Watt 113,3 meter 10 meter 230V 14,8

36

MAGNUM Trace WaterSelf-regulating heating cable for waterpipes < 65°C

MAGNUM Trace Water (MTW) is a self-regulating heating cablethat can be used for internal as well as external frost protection of water pipes. It can also be cut to length at site and exact piping lengths can be matched without any complicated design considerations. Its self-regulating characteristics improve safety and reliability, as the heat output is regulated by the pipe temperature. The MAGNUM Trace Water is equipped with a Polyole�n outerjacket that covers all requirements and therefore safely to be used in combination with drinking water. MAGNUM Trace Water KitReady to use heating elements including:• MTW self regulating cable with end seal• 3/4-inch brass cable lead and pipe connector• Power lead connection kit

Additional informationThe extent of the loss of heat depends on the diameter of the piping, the ambient temperature and the �ow of liquid. Extra insulation is advised. Use of a temperature regulator reduces energy consumption. For calculating the heat loss and the applicable cable, you cancontact the sales department of MAGNUM Heating.

Complete installation of MTW Kit:

Connecting wire Connection set MTW cable Water Supply3/4 inch wire guide

Page 37: Productcatalog - Magnum€¦ · 125012 1200 Watt 40 meter 10 meter 230V 5,2 44,1 125019 1900 Watt 63,3 meter 10 meter 230V 8,3 27,8 125034 3400 Watt 113,3 meter 10 meter 230V 14,8

37

Maximum temperature Without power 65°CVoltage 230VMinimum bending radius 25 mmMax. cable length 100 meter with 16 amp circuit breakerLowest installation temp. -40°CDimensions (mm) 8 x 5,9 mmWeight 7,3 kg/100 mColor VioletApprovals CE, According to DIN EN 62395-1

MTW KitReady to use heating elements incl .:- MTW self-regulating cable with end seal- 3/4-inch copper conductor cable / pipe connection- Connection set for power supply

WARNING: Heating cables in combination with drinking water pipes must be controlled at all times thermostatically.

Part.no. Type Capacity Voltage

159000 MTW-10 10 Watt @ 10°C 230V

Options

pag. 40-45

Kits

159002 MTW-Kit 2 meter 20 Watt @ 10°C 230V

159003 MTW-Kit 3 meter 30 Watt @ 10°C 230V

159004 MTW-Kit 4 meter 40 Watt @ 10°C 230V

159005 MTW-Kit 5 meter 50 Watt @ 10°C 230V

159006 MTW-Kit 6 meter 60 Watt @ 10°C 230V

159008 MTW-Kit 8 meter 80 Watt @ 10°C 230V

159010 MTW-Kit 10 meter 100 Watt @ 10°C 230V

159013 MTW-Kit 13 meter 130 Watt @ 10°C 230V

159020 MTW-Kit 20 meter 200 Watt @ 10°C 230V

159025 MTW-Kit 25 meter 250 Watt @ 10°C 230V

Technical details

1.2 mm2 tinned copper wire

self-limiting heating

TPE insulation

earthed braid

Polyole�n protective sheath

MTW Kit

2 YEARWARRANTY

Page 38: Productcatalog - Magnum€¦ · 125012 1200 Watt 40 meter 10 meter 230V 5,2 44,1 125019 1900 Watt 63,3 meter 10 meter 230V 8,3 27,8 125034 3400 Watt 113,3 meter 10 meter 230V 14,8

38

Self-regulating heating cable for hot water systems < 85°C

MAGNUM Trace Hot Water (MTHW ) is a self-regulating heating cable designed to compensate for heat loss from hot water distribution systems. When hot taps are not continuous used, the water in the distribution pipework cools and is usually run to waste before hot water from the source arrives at the tap. This MTHW does not become overheated and does not burn, even when it overlaps on itself. The electrical current regulates itself based on the temperature of the pipe. It’s self-regulating characteristics improve safety and reliability. By applying to the pipework (beneath the thermal insulation), heat losses are eliminated and the water is maintained at the required temperature. The installation of MTHW is quick and simple and the cable canbe cut to match the exact length of the pipework. It requires no special skills or tools. Termination, splicing and power connection is available separately.

Additional informationThe extent of heat loss depends on the diameter of the piping, the ambient temperature and the flow of liquid. Extra insulation is advised. Use of a temperature regulator reduces energy consumption. For calculating the heat loss and the applicable cable, you cancontact the sales department of MAGNUM Heating.

MAGNUM Trace Hot Water

Page 39: Productcatalog - Magnum€¦ · 125012 1200 Watt 40 meter 10 meter 230V 5,2 44,1 125019 1900 Watt 63,3 meter 10 meter 230V 8,3 27,8 125034 3400 Watt 113,3 meter 10 meter 230V 14,8

39

Maximum temperature De-energized 85°C / energized 65°CIntermittent 1000 cumulative hoursNominal voltage 230 V (120 V available to order)Minimum bending radius 25 mmMinimum installation temp. -30°CMaximum resistance of braid 18.2 Ohms/kmDimensions (mm) 13 x 6,8 mmWeight 12 kg/100 mColor BrownApprovals CE/VDE, according to DIN EN 62395-1

Maximum length (m) vs. circuitbreaker size:

Category Switch 230VReference Temp. 6A 10A 16A 20AMTHW-9 18oC 56 92 128 - 0oC 38 64 102 128MTHW-12 18oC 34 56 90 94 0oC 24 40 64 80

For use with Type C circuit breakers to BS EN60898:1991

Recommended insulation thickness (mm):

Category Maintain Pipe size (mm)Reference Temp. 15 22 28 35 42 54MTHW-9 60oC 25 30 40 50 60 75 55oC 20 25 30 40 50 60 50oC 15 20 25 30 40 50MTHW-12 45-70oC 30 40 50 60 75 75

The above �gures are based on the thermal insulation having a K-value of 0.038W/mK at 36°C mid-point temperature.

Part.No. Type Capacity Voltage

159555 MTHW-9 9 Watt @ 55°C 230V

159565 MTHW-12 12 Watt @ 65°C 230V

Options

pag. 40-45

Technical details

1.2 mm2 tinned copper wire

self-limiting heating

  protective insulation

TPE insulation

earthed braid

TPE protective sheath

2 YEARWARRANTY

Page 40: Productcatalog - Magnum€¦ · 125012 1200 Watt 40 meter 10 meter 230V 5,2 44,1 125019 1900 Watt 63,3 meter 10 meter 230V 8,3 27,8 125034 3400 Watt 113,3 meter 10 meter 230V 14,8

40

Thermostats for MAGNUM Tracing

893550 ETO-4550 Din rail thermostat temperature / moisture 3 x 16A - 230 Volt

An intelligent all-in-one solution for melting snow and ice. Optimal operation is guaranteed by power regulating which renders the system e�ective and economical.

• Electronic on/o� switch up to 11kW• 2 zone control, can be individually controlled simultaneously• Economical control - minimum energy consumption• Detection of temperature and moisture (moisture sensitivity can be regulated)• Display and “turn/press control” for easy programming• Language options

900056 ETN-4 Digital din rail thermostat -20/+70°C 16A - 230 Volt + �oor sensor

The ETR-2 gives an economical control for melting snow and ice in smaller applications. With a focus on energy use and easy installation, the ETR-2 keeps gutters and small surfaces free of snow and ice.

• Monitoring of melting of snow and ice in outside areas and gutters• Detection of temperature and moisture (moisture sensitivity can be regulated)• Electronic on/o� switch up to 3600 Watt• For application on roof or eaves• Easy to install

892551 ETN-4 Digitale DIN-rail thermostaat -20/+70oC 16A - 230 V + vloersensor

An all-in-one thermostat with extensive temperature regulation, suitable for a wide range of applications. Easy to operate and program.

• This thermostat is perfect for: frost protection, melting ice & snow• Extensive temperature range: -19.5° to +70°C• Entry for night lowering and frost protection• Optimal safety due to built-in 2 pole 16A interrupter• Simple menu navigation and programming make for a quick set-up• Big backlit display• Supplied with thin �oor sensor

891551 ETI-1551 Din rail thermostat -10/+50°C 230V 10A

For frost protection of pipework. The ETI-1551 is an on/o� thermostat with adaptable di�erentiation for temperature control. Because the ETI is equipped with changeover relay, the thermostat can be used as a cooler thermostat. This thermostat can be used in combination with the ETF-622 pipesensor (art. 891650)

Page 41: Productcatalog - Magnum€¦ · 125012 1200 Watt 40 meter 10 meter 230V 5,2 44,1 125019 1900 Watt 63,3 meter 10 meter 230V 8,3 27,8 125034 3400 Watt 113,3 meter 10 meter 230V 14,8

41

Sensors for MAGNUM Tracing

900055 ETOR-55 Sensor unit moisture for eaves incl. 10 meters of connecting cable

This humidity sensor is specially designed for installation in gutters and drains.It can only be used in combination with outdoor sensor type ETF-744/99.

891650 ETF-633/44/55 Pipe sensor -20 /+70°C

To be connected to a DIN rail thermostat. This sensor has a large area and hence versatile. The metal housing provides fast and accurate measurement of the temperature.

901441 ETF-744/99 External Outdoor temperature sensor

This Outdoor sensor only records the temperature. To use in combination with outdoor sensor type ETOR-55 or only for temperature detection.

860199 ETF-144 Floor sensor -20/+70°C

Standard NTC �oor sensor for �oor temperature detection.

Part.no. Thermostats t.b.v. MAGNUM Tracing

893550 ETO-4550 Din rail thermostat temperature / moisture 3 x 16A - 230 Volt

900056 ETN-4 Digital din rail thermostat -20/+70°C 16A - 230 Volt + �oor sensor

892551 ETN-4 Digitale DIN-rail thermostaat -20/+70oC 16A - 230 V + vloersensor

891551 ETI-1551 Din rail thermostat -10/+50°C 230V 10A

Sensors t.b.v. MAGNUM Tracing

900055 ETOR-55 Sensor unit moisture for eaves incl. 10 meters of connecting cable

901441 ETF-744/99 External Outdoor temperature sensor

891650 ETF-633/44/55 Pipe sensor -20 /+70°C

860199 ETF-144 Floor sensor -20/+70°C

Page 42: Productcatalog - Magnum€¦ · 125012 1200 Watt 40 meter 10 meter 230V 5,2 44,1 125019 1900 Watt 63,3 meter 10 meter 230V 8,3 27,8 125034 3400 Watt 113,3 meter 10 meter 230V 14,8

42

Connecting materials for MAGNUM Tracing

159712 Dividing unit for MTR, MTGH and MTHW159713 Dividing unit for MTM & MTW

Connection piece (T) for connecting or splitting tracing cables. Supplied including 2x Shrinkage insulation end seal kits

Dimensions (mm) 36 x 137 x 118 mmClass IP54-IP65Operating temp. -40ºC tot +125ºC

159710 Connection unit for MTR, MTGH & MTHW159711 Connection unit for MTM & MTW

Connection piece (straight) for connecting or transferring tracing cables. Supplied with 1 x shrinkage insulation end seal kit.

Technical detailsDimensions 159710: 32 mm x 130 mm 159711: 26,5 mm x 120 mm Class IP68 / 5 BarT marking T85oCOperating temp. -40oC tot +125oCTracing index PTI250

Connecting cable Extend cable

T-connection T-divider

Page 43: Productcatalog - Magnum€¦ · 125012 1200 Watt 40 meter 10 meter 230V 5,2 44,1 125019 1900 Watt 63,3 meter 10 meter 230V 8,3 27,8 125034 3400 Watt 113,3 meter 10 meter 230V 14,8

43

910060 Cable gel connection piece

A universal connection piece that is also suitable for each cable type. Highly reliable and can be installed without advanced tools.

Connection Increasing cable length Y-connection End seal

160100 Shrinkage insulation connection kit

For connecting an connection cable, connectingcables to each other, or repairing damaged cables.Kit contains all needed components, including shrink tubing and connectors. Use: 1 kit for each cable.

160103 Shrinkage insulation end seal kit

For sealing a cable end. Use: 1 Shrink tube per cable end.

Art.nr. Connection Materials for MAGNUM Tracing

159710 Connection unit for MTR, MTGH en MTHW

159711 Connection unit for MTM & MTW

159712 Dividing unit (T) for MTR, MTGH en MTHW

159713 Dividing unit (T) for MTM & MTW

910060 Cable gel connection piece

160100 Shrinkage connection kit

160103 Shrinkage end sealing kit

Page 44: Productcatalog - Magnum€¦ · 125012 1200 Watt 40 meter 10 meter 230V 5,2 44,1 125019 1900 Watt 63,3 meter 10 meter 230V 8,3 27,8 125034 3400 Watt 113,3 meter 10 meter 230V 14,8

44

910033 Glass �ber tape

Special adhesive glass �bre tape for installing a tracing cable on piping.

Breadth tape 25 mmLength tape 33 metersInstallation 3 windings for each 30 cm

720200 Alutape 50 mm x 22,5 meter

Especially for winding around plastic piping when a tracing cable is needed. This tape gives a higher heat outlet for plastic piping.

Breadth tape 50 mmLength tape 22,5 meters

Mounting materials for MAGNUM Tracing

160105 Connection box IP 55

Aansluitdoos IP55 inclusief DIN-rail aansluitklemmen. T.b.v. aansluiten of splitsen van meerdere tracing kabels.

Technische detailsIP-Klasse IP55Afmetingen 125 x 125 x 75 mm

160109 Cable gland (20mm) for MTM, MTW, MTR and MTGH

For feeding an MTM, MTW, MTR and MTGH tracing cable through into an connection box. One gland for each cable.

159001 ¾” Brass cable conductor/pipe connection for MTW

Brass cable conductor for watertight sealing of the water pipe. For applying a MAGNUM Trace Water in a water pipe with a minimum diameter of 22 mm.

160110 Cable gland (25mm) for MTHW

For feeding an MTHW tracing cable through into an connection box. One gland for each cable.

Page 45: Productcatalog - Magnum€¦ · 125012 1200 Watt 40 meter 10 meter 230V 5,2 44,1 125019 1900 Watt 63,3 meter 10 meter 230V 8,3 27,8 125034 3400 Watt 113,3 meter 10 meter 230V 14,8

45

Part.no. Mounting materials for MAGNUM Tracing

160105 Connection box IP 55

160109 Cable gland (20mm) for MTM, MTW, MTR and MTGH

160110 Cable gland (25mm) for MTHW

159001 ¾” Brass cable conductor/pipe connection for MTW

910033 Glass �bre tape 25 mm x 33 meters

720200 Alutape 50 mm x 22.5 meters

160107 Support bow for eaves | Set of 3 pieces

160108 Eaves clips | Set of 10 pieces

160113 Warning Sticker | Set of 5 pieces

160107 Support bracket for gutter-Set of 3 pieces

These support brackets support the cable and keep it in position in the gutter or drain. In gutters where 2 cables are needed, these brackets make sure the cables stay at the correct distance.

160108 Gutter clips-Set of 10 pieces

With these gutter clips you can �x the cables in the eaves in an easy manner. Needed: 1 clip per 0.5 meter tracing.

160113 Warning sticker- per set of 5 pieces

To be applied as a warning in places where tracing has been installed.

Page 46: Productcatalog - Magnum€¦ · 125012 1200 Watt 40 meter 10 meter 230V 5,2 44,1 125019 1900 Watt 63,3 meter 10 meter 230V 8,3 27,8 125034 3400 Watt 113,3 meter 10 meter 230V 14,8

46

Notes

Page 47: Productcatalog - Magnum€¦ · 125012 1200 Watt 40 meter 10 meter 230V 5,2 44,1 125019 1900 Watt 63,3 meter 10 meter 230V 8,3 27,8 125034 3400 Watt 113,3 meter 10 meter 230V 14,8

47

Notes

Page 48: Productcatalog - Magnum€¦ · 125012 1200 Watt 40 meter 10 meter 230V 5,2 44,1 125019 1900 Watt 63,3 meter 10 meter 230V 8,3 27,8 125034 3400 Watt 113,3 meter 10 meter 230V 14,8

48

MAGNUM HeatingC&F Technics B.V.Slabbecoornweg 41NL - 4691 RZ Tholen

T +31(0)166-609 300F +31(0)166-604 877E [email protected] magnumheating.nl

v0116