Products Guide V01 - ParagonEfficient project management thanks to Climaveneta as unique project leader. Complete and specialized Organization Climaveneta qualifies itself for the

  • Upload
    others

  • View
    3

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Products Guide V01 - ParagonEfficient project management thanks to Climaveneta as unique project leader. Complete and specialized Organization Climaveneta qualifies itself for the
Page 2: Products Guide V01 - ParagonEfficient project management thanks to Climaveneta as unique project leader. Complete and specialized Organization Climaveneta qualifies itself for the
Page 3: Products Guide V01 - ParagonEfficient project management thanks to Climaveneta as unique project leader. Complete and specialized Organization Climaveneta qualifies itself for the

2011Products Guide V01

Page 4: Products Guide V01 - ParagonEfficient project management thanks to Climaveneta as unique project leader. Complete and specialized Organization Climaveneta qualifies itself for the

And sometimes even a thousand words are not enough. Because it is hard to list all the reasons that explain why Climaveneta is the preferred partner air conditioning in the most challenging projects all around the world.

In fact our success is a delicate balance of vision, experience and cutting-edge technology. It is not just comfort, it is a question of flexibility and care, adapting the system to the requirements of each building and application, emulating their users’ needs. All over the world, no matter how harsh the climate, how demanding each project can be, every single choice is focussed on offering the most efficient, reliable and sustainable solution.

Climaveneta. There are many reasons.

Sometimes numbers say more than a thousand words

Head offices and foreign branches- Climaveneta SpA in Italy- Climaveneta France- Climaveneta Deutschland- Climaveneta España- Climaveneta Poland- Climaveneta Chat Union Refrig. Equipment Co Ltd in China

Distributors Over 55 distributors in more than 100 countries of the

world for a truly complete market coverage.

Service Service is assured in all countries through the assistance

networks of our subsidiaries and distributors with highest expertise, a wide range of after sales service contracts for a truly complete support.

Bassano del Grappa (Vicenza)HeadquartersProductive area: 12.500m2

Employees: 230

Production of: Chillers: air and water cooled, from 30 to 700kW Reversible units: air and water cooled, up to 400kW Multipurpose up to 400KW Chillers with free-cooling up to 300kW

Pieve díAlpago (Belluno)ClimavenetaTraining centreProductive area: 7.000m2

Employees: 50

Production of: Air handling units

Pieve d'Alpago (Belluno)Productive area: 25.000m2

Employees: 210

Production of: Chillers: air and water cooled, from 200 to 1700kW Heat pumps air and water cooled, up to 2400KW

Multipurpose up to 700KW Chillers with free-cooling up to 1250kW

Mignagola(Treviso)Productive area: 20.000m2

Employees: 160

Production of: Split systems, multisplit Chillers and Heat pumps up to 150kW Hydronic fan coils from 1 to 30kW Close control units

Shanghai(China)Sales department for China and far eastProductive area: 25.000m2

Employees: 330

Production of: Air cooled chillers & heat pumps

from 40 to 1700kW

Water cooled chillers & heat pumps from 10 to 3070kW

Parets del Valles (Spain)Productive area: 2.500m2

Employees: 45

Production of: Direc expansion units Compact units Rooftop units for small and medium applications

Shell & tube evaporators Roof-top units up to 500kW Telecommunications units

Page 5: Products Guide V01 - ParagonEfficient project management thanks to Climaveneta as unique project leader. Complete and specialized Organization Climaveneta qualifies itself for the

And sometimes even a thousand words are not enough. Because it is hard to list all the reasons that explain why Climaveneta is the preferred partner air conditioning in the most challenging projects all around the world.

In fact our success is a delicate balance of vision, experience and cutting-edge technology. It is not just comfort, it is a question of flexibility and care, adapting the system to the requirements of each building and application, emulating their users’ needs. All over the world, no matter how harsh the climate, how demanding each project can be, every single choice is focussed on offering the most efficient, reliable and sustainable solution.

Climaveneta. There are many reasons.

Sometimes numbers say more than a thousand words

Head offices and foreign branches- Climaveneta SpA in Italy- Climaveneta France- Climaveneta Deutschland- Climaveneta España- Climaveneta Poland- Climaveneta Chat Union Refrig. Equipment Co Ltd in China

Distributors Over 55 distributors in more than 100 countries of the

world for a truly complete market coverage.

Service Service is assured in all countries through the assistance

networks of our subsidiaries and distributors with highest expertise, a wide range of after sales service contracts for a truly complete support.

Bassano del Grappa (Vicenza)HeadquartersProductive area: 12.500m2

Employees: 230

Production of: Chillers: air and water cooled, from 30 to 700kW Reversible units: air and water cooled, up to 400kW Multipurpose up to 400KW Chillers with free-cooling up to 300kW

Pieve díAlpago (Belluno)ClimavenetaTraining centreProductive area: 7.000m2

Employees: 50

Production of: Air handling units

Pieve d'Alpago (Belluno)Productive area: 25.000m2

Employees: 210

Production of: Chillers: air and water cooled, from 200 to 1700kW Heat pumps air and water cooled, up to 2400KW

Multipurpose up to 700KW Chillers with free-cooling up to 1250kW

Mignagola(Treviso)Productive area: 20.000m2

Employees: 160

Production of: Split systems, multisplit Chillers and Heat pumps up to 150kW Hydronic fan coils from 1 to 30kW Close control units

Shanghai(China)Sales department for China and far eastProductive area: 25.000m2

Employees: 330

Production of: Air cooled chillers & heat pumps

from 40 to 1700kW

Water cooled chillers & heat pumps from 10 to 3070kW

Parets del Valles (Spain)Productive area: 2.500m2

Employees: 45

Production of: Direc expansion units Compact units Rooftop units for small and medium applications

Shell & tube evaporators Roof-top units up to 500kW Telecommunications units

Page 6: Products Guide V01 - ParagonEfficient project management thanks to Climaveneta as unique project leader. Complete and specialized Organization Climaveneta qualifies itself for the

Mission

“To develop efficient and reliable air conditioning solutions in order to emulate our customers’ expectations”.

Climaveneta is aware that the HVACR systems are among the most crucial in modern buildings.The use, energy efficiency and environmental sustainability of such spaces depend upon these systems, as well as the health and well-being of the people who spend their time there, whatever is the purpose - offices, residential, commercial centres, hotels, hospitals, leisure areas.

Values

Every strategic- and organizational choice is based upon fundamental values:

Energy efficiency: continuous strive towards the most intelligent

and sustainable use of energy resources, extended to all solutions, for both cooling and heating, with every type of product: complete efficiency, 365 days a year.

Comfort: well-being created in enevery application with

maximum efficiency and minimum environmental impact, thanks to the uncompromising attention to the specific requirements of each project.

“Custom Made” approach: conjugate tailor-made solutions with advanced

industrial processes, to ensure the answer to the needs of every user, application and building features, with the quality and advantages of a modern manufacturing organization.

Environment and Social responsibility:

continuously improve the sustainability of its activities and products, particularly in terms of energy consumption and environmental impact. A value which is witnessed by Climaveneta with the ISO 14001 certification, successfully obtained in December 2009.

For 40 yearsmission and values have been leading our activity and are the basis of our results.

1st in Europe and 5th in the world

This mission and values have been at the core of our activity for 40 years and have enabled us to become the 1st European manufacturer and the 5th world group in the HVACR industry. Achievements proven by the numbers of our group:

188 milions Euro turnover 2009

23 milions Euro EBITDA 2009

Page 7: Products Guide V01 - ParagonEfficient project management thanks to Climaveneta as unique project leader. Complete and specialized Organization Climaveneta qualifies itself for the

Mission

“To develop efficient and reliable air conditioning solutions in order to emulate our customers’ expectations”.

Climaveneta is aware that the HVACR systems are among the most crucial in modern buildings.The use, energy efficiency and environmental sustainability of such spaces depend upon these systems, as well as the health and well-being of the people who spend their time there, whatever is the purpose - offices, residential, commercial centres, hotels, hospitals, leisure areas.

Values

Every strategic- and organizational choice is based upon fundamental values:

Energy efficiency: continuous strive towards the most intelligent

and sustainable use of energy resources, extended to all solutions, for both cooling and heating, with every type of product: complete efficiency, 365 days a year.

Comfort: well-being created in enevery application with

maximum efficiency and minimum environmental impact, thanks to the uncompromising attention to the specific requirements of each project.

“Custom Made” approach: conjugate tailor-made solutions with advanced

industrial processes, to ensure the answer to the needs of every user, application and building features, with the quality and advantages of a modern manufacturing organization.

Environment and Social responsibility:

continuously improve the sustainability of its activities and products, particularly in terms of energy consumption and environmental impact. A value which is witnessed by Climaveneta with the ISO 14001 certification, successfully obtained in December 2009.

For 40 yearsmission and values have been leading our activity and are the basis of our results.

1st in Europe and 5th in the world

This mission and values have been at the core of our activity for 40 years and have enabled us to become the 1st European manufacturer and the 5th world group in the HVACR industry. Achievements proven by the numbers of our group:

188 milions Euro turnover 2009

23 milions Euro EBITDA 2009

Page 8: Products Guide V01 - ParagonEfficient project management thanks to Climaveneta as unique project leader. Complete and specialized Organization Climaveneta qualifies itself for the

Lean Manufacturing

The whole production is structured according to lean thinking principles. It represents one of the best examples of lean manufacturing implementation in Europe. This commitment enables several advantages:

Increased efficiency,

Higher quality standardsi,

Best process integration.

From the productto the system

We have integrated products into plug&play rational and efficient systems, complete with all the necessary components in order to ensure:

Perfect comfort and complete adaptability to specific applications,

High efficiency,

Lower installation costs,

Smooth and easy on site operations,

Efficient project management thanks to Climaveneta as unique project leader.

Complete and specialized Organization

Climaveneta qualifies itself for the consistency of both its proposal and organization. Specific approaches stem from such consistent yet broad offer, namely in Operations and R&D: the production is implemented in 5 focus factories, each specializing in terms of product types.

A complete range of products from 1 to 2400kW, a brand that is synonymous for reliability and quality, with all the advantages that only a leading group, De’Longhi, can offer, as far as manufacturing, know-how and customer orientation are concerned.

All this isClimaveneta.

Page 9: Products Guide V01 - ParagonEfficient project management thanks to Climaveneta as unique project leader. Complete and specialized Organization Climaveneta qualifies itself for the

Lean Manufacturing

The whole production is structured according to lean thinking principles. It represents one of the best examples of lean manufacturing implementation in Europe. This commitment enables several advantages:

Increased efficiency,

Higher quality standardsi,

Best process integration.

From the productto the system

We have integrated products into plug&play rational and efficient systems, complete with all the necessary components in order to ensure:

Perfect comfort and complete adaptability to specific applications,

High efficiency,

Lower installation costs,

Smooth and easy on site operations,

Efficient project management thanks to Climaveneta as unique project leader.

Complete and specialized Organization

Climaveneta qualifies itself for the consistency of both its proposal and organization. Specific approaches stem from such consistent yet broad offer, namely in Operations and R&D: the production is implemented in 5 focus factories, each specializing in terms of product types.

A complete range of products from 1 to 2400kW, a brand that is synonymous for reliability and quality, with all the advantages that only a leading group, De’Longhi, can offer, as far as manufacturing, know-how and customer orientation are concerned.

All this isClimaveneta.

Page 10: Products Guide V01 - ParagonEfficient project management thanks to Climaveneta as unique project leader. Complete and specialized Organization Climaveneta qualifies itself for the

Climaveneta, consistently with the De’Longhi Group Policy – believes in the integrated Quality, Environment, Safety System as the best guarantee for all stakeholders in achieving the highest quality, reliability and competitiveness of the products and in complying with highest standards of safeguarding the environment and human resource safety.For further information www.climaveneta.com

Integrated quality - envirionment - safety policy

Climaveneta S.p.A.:

Environmental Management System complying with the requirements of UNI EN ISO14001:2004 norm

Quality System complying with the requirements of UNI EN ISO9001:2008 norm

This company participatesin the Eurovent Certification Programme.

The products are listed in the Directory of certified products.

The Eurovent certificate, for the applicable units, refers to products with cooling capacity up to 600 kW,

voluntarily extended up to 1500 kW, for air-cooled models and up to 1500 kW

for water-cooled models.

Page 11: Products Guide V01 - ParagonEfficient project management thanks to Climaveneta as unique project leader. Complete and specialized Organization Climaveneta qualifies itself for the

Legenda

The functions and characteristics are subject to each model’s size, configuration, optional.Performance data, pictures, schematics and other features contained in this document are provided exclusively on informa-tional purpose about our product range. They refer to standard execution, applicable to the European Union market. They can be varied any time without notice. For further information please contact Climaveneta Sales/Marketing Offices or visit www.climaveneta.it.

Functions

Cooling

Heating

Combined production of heating, cooling and domestic hot water

HEAT PUMP

REVERSIBLE

Combined production of heating and cooling

Domestic hot water production

Free-cooling

Humidification

Reheat

Thermodynamic effect

2 PIPESSuitable for 2-pipe system

4 PIPESSuitable for 4-pipe system

Further features

Integrated electronic controller (can be optional)

ENERGY CLASSClass A Energy efficiency

Leakage class B according to BS EN 1886

Eurovent Certification

VSpeed

VAir

VPF

Patent Pending

4 patents pending

Fan

Axial fan

Centrifugal fan

Plug fan

Tangential fan

Recovery

Plate heat recovery

ROTARYRotary enthalpy recovery

Water heat exchanger

Plate heat exchanger

Shell & tube heat exchanger

Refrigerant

Refrigerant

Compressor

Centrifugal compressor

Scroll compressor

Reciprocating compressor

Rotary compressor

Screw compressor

Tipologia

WALL

Wall split

CASSETTE

Cassette

DUCT

Duct

FAN COIL

Vertical/Orizzontal

Page 12: Products Guide V01 - ParagonEfficient project management thanks to Climaveneta as unique project leader. Complete and specialized Organization Climaveneta qualifies itself for the

Index

Functions Refrig. Compressors FanHeat

Exchangers

Pag. Product CapacityCOOLING HEATING SCROLL AXIAL CENTRIFUGAL PLATES

Chillers, air source16 BRAT 4,9 - 32,9 kW • R410A • • •20 MICS 18,2 - 44,7 kW • R410A • • •22 BRA 4,9 - 15,4 kW • R410A • • •24 MICS-C 18,2 - 31,8 kW • R410A • • •

Chillers, water source26 BRH 5,5 - 35,1 kW • R410A • •

Condenserless chillers30 HE FF 4,7 - 32,4 kW • R407C • •32 NHCR 8,6 - 41,9 kW •

Reversible units, air source34 BRAN 4,6 - 35,5 kW • • R410A • • •38 MICS-N 17,3 - 47,9 kW • • R410A • • •40 BRN 4,6 - 16,8 kW • • R410A • • •42 MICS-CN 17,3 - 33,9 kW • • R410A • • •

Reversible units, water source44 WWr MTD 5,2 - 41,7 kW • • R410A • •

Hydronic - residential

Functions Refrig. Compressors FanHeat

Exchangers

Pag. Product CapacityCOOLING SCROLL AXIAL EC FAN PLATES

Reversible heat pump with inverter compressor, total heat recovery, air source

48 i-NRG 16,3 kW • • • R410A • • • •

50 AWR-DHW 7,7 - 33,5 kW • • • R407C • • •

Reversible heat pump, air source

52 AWR-MTD1 6,9 - 17,4 kW • • • R410A • • •

54 AWR-MTD-XE 6,3 - 17,9 kW • • • R410A • • •

Heat pump, air source56 AW-HT 10,4 - 19,7 kW • • R407C • • •

Reversible heat pump, water source58 WWR-MTD 7,2 - 43,8 kW • • • R410A • •

60 WWR-HT Slim 8,3 - 14,1 kW • • • R407C • •

62 WWR-HT Cube 8,3 - 35,9 kW • • • R407C • •

Reversible heat pump, total heat recovery, water source64 WWR-DHW 6,0 - 40,5 kW • • • R407C • •

Reversible heat pump, geothermal source66 BWR-MTD 5,4 - 33,3 kW • • • R410A • •

68 BWR-HT Slim 6,2 - 10,6 kW • • • R407C • •

70 BWR-HT Cube 6,2 - 27,0 kW • • • R407C • •

Reversible heat pump, total heat recovery, geothermal source72 BWR-DHW 4,5 - 29,7 kW • • • R407C • •

PRANA

HEATING HOT WATER

Page 13: Products Guide V01 - ParagonEfficient project management thanks to Climaveneta as unique project leader. Complete and specialized Organization Climaveneta qualifies itself for the

Functions Refrig. Compressors Fan Heat Exchangers

Pag. Product CapacityCOOLING HEATING FREE COOLING CENTRIFUGAL AXIAL CENTRIFUGAL PLATES SHELL & TUBES

Reversible units, air source146 NECS-N 35,8 - 322 kW • • R410A • •

152 NECS-N 50,3 - 169 kW • • R410A • •

154 NECS-N 339 - 898 kW • • R410A • •

158 NECS-ST-N 103 - 322 kW • • R410A • •162 RECS 195 - 385 kW • • R134a • •166 RECS 195 - 385 kW • • R134a • •

170 FOCS-N 439 - 1160 kW • • R134a • •

174 NECS-CN 36,0 - 303 kW • • R410A • •

Reversible units, water source176 NECS-WN 43,4 - 371 kW • • R410A •178 RECS-W 174 - 801 kW • • R134a •

Reversible units, NRG line, total heat recovery, air source180 NECS-NR 36 - 311 kW • • R410A • •

184 NECS-NR 353 - 823 kW • • R410A • •

188 FOCS-NR 200 - 826 kW • • R134a • •

Reversible units, NRG line, total heat recovery, water source

192 NECS-WNR 5,7 - 491 kW • • R410A •

194 FOCS-WNR 194 - 891 kW • • R134a •

Hydronic - reversible

Functions Refrig. Compressors Fan Heat Exchangers

Pag. Product CapacityCOOLING HEATING FREE COOLING CENTRIFUGAL SCROLL SCREW AXIAL CENTRIFUGAL PLATES SHELL & TUBES

Chillers, air source for outdoor installation76 NECS 33,8 - 341 kW • R410A • • •

82 NECS 53,0 - 159 kW • R410A • • •

86 NECS 354 - 885 kW • R410A • • •

90 NECS-ST 104 - 341 kW • R410A • • •94 FOCS 145 - 516 kW • R134a • • •98 FOCS 277 - 516 kW • R134a • • •100 FOCS 294 - 1744 kW • R134a • • •104 FOCS-XL 272 - 1180 kW • R134a • • •106 FOCS-CA 310 - 1381 kW • R134a • • •110 i-FOCS 511 - 842 kW • R134a • • •

112 TECS2 Vision 2.0 220 - 1325 kW • R134a • • •

114 NECS-FC 41,5 - 377 kW • • R410A • • •120 FOCS-FC 329 - 1229 kW • • R134a • • •124 NECS-C 37,1 - 325 kW • R410A • • •

Chiller, water source128 NECS-W 43,4 - 371 kW • • R410A • •130 FOCS-W 87,0 - 447 kW • • R134a • •

132 FOCS2-W 321 - 1299 kW • • R134a • •

136 TECS2-W Vision 2.0 241 - 1949 kW • • R134a • •

Condenserless chiller

138 NECS-ME 39,5 - 432 kW • R410A • •

140 FOCS-ME 79,2 - 410 kW • R134a • •142 FOCS-ME 219 - 2240 kW • R134a • •

Hydronic - chiller

Page 14: Products Guide V01 - ParagonEfficient project management thanks to Climaveneta as unique project leader. Complete and specialized Organization Climaveneta qualifies itself for the

Functions Refrig. Compressors Fan

Pag. Product CapacityCOOLING FREE COOLING SCROLL AXIAL CENTRIFUGAL EC FAN

Close control unit, direct expansion

260 i-AX 7 - 100 kW • R410A • •

262 i-AW 7 - 100 kW • R410A •

264 ACCURATE AX 7 - 90 kW • R410A • •266 ACCURATE AW 7 - 90 kW • R410A • •268 ACCURATE AD 20-100kW • R410A • •270 ACCURATE AT 20-100kW • R410A • •272 ACCURATE AF 20-100kW • • R410A • •

Close control units, chilled water274 ACCURATE AC 8 - 185 kW • •278 ACCURATE AB 20-110 kW • •

Remote condensers

280 BRE R410A •

282 BRC R407C •284 ARCC R407C •

Dry cooler286 BDC •

HPAC

Functions Refrig. Compressors Fan Heat Exchangers

Pag. Product CapacitySYSTEM

4 PIPE

SCROLL SCREW AXIAL PLATES SHELL & TUBES

INTEGRA unit for 4-pipe systems, air source198 NECS-Q 36 - 311 kW • R410A • • •

202 NECS-Q 353 - 823 kW • R410A • • •

206 ERACS2-Q 200 - 826 kW • R134a • • •

210 i-FX-Q 479 - 811 kW • R134a • •

INTEGRA unit for 4-pipe systems, water source

214 NECS-WQ 45,7 - 491 kW • R410A • •

216 ERACS2-WQ 194 - 891 kW • R134a • •

INTEGRA

Type Functions Fan

Pag. Product CapacityWALL FAN COIL CASSETTE DUCT 2 PIPES 4 PIPES TANGENZIALE CENTRIFUGAL

Fan-coils220 a-LIFE 1,45 - 22,42 kW • • • •230 a-LIFE HP 2,83 - 19,38 kW • • • • •

234 i-LIFE 1,41 - 7,47 kW • • • •

240 NFT 0,86 - 4,25 kW • • • •

Hi-wall type terminals

244 MHD 1,9 - 4,6 kW • • •

Ducted type terminals250 HWD 4,8 - 29 kW • • • •254 HWD-HP 16,8 - 60,4 kW • • • •

Heat recuperators 256 HRD 290 - 4000 m3/h •

Hydronic terminals

Page 15: Products Guide V01 - ParagonEfficient project management thanks to Climaveneta as unique project leader. Complete and specialized Organization Climaveneta qualifies itself for the

Functions Refrig. Compressors Fan

Pag. Product CapacityCOOLING SCROLL RECIPROCATING AXIAL

Condensing units

338 BRAT-MC 4,9 - 32,9 kW • R-410A • •

340 HCAT 38 - 160 kW • R407C • •344 MCAT 119 - 325 kW • R407C • •348 NCE 55 - 389 kW R-410A •

352 FCE 79 - 894 kW R234A •

Functions Fan Elettr.

Pag. Product CapacityCOOLING HEATING RE-HEATING HUMIDIFICATION CENTRIFUGAL PLUG FAN CONTROLLER

Air handling units334 WIZARD 0-115000 m3/h • • • • • • •

Pag. Product

Group devices324 MANAGER 3000

325 SEQUENCER

Metering devices

326 DEMETRA

Supervision devices327 FWS3

328 FWS3000

IDRORELAX330 IDRORELAX

Systems

AHU

Other

Functions Refrig.Com-

pressorsRecupero Sez. Int. Sez. Est.

Pag. Product CapacityCOOLING HEATING FREE COOLING THERMODYNAMIC SCROLL PLATE ROTARY CENTRIFUGAL PLUG FAN AXIAL

Rooftop units, for medium crowding applications290 WORK 37,4 - 198 kW • • • • R410A • • •292 WORK-T 34,7 - 200 kW • • • R410A • • •294 WHISPER 35,7 - 197 kW • • • • R410A • • •296 WHISPER-T 35,8 - 197 kW • • • R410A • • •

Rooftop units with enthalpy recovery for medium crowding applications

298 i-WHISPER ENTHALPY 87,0 - 338 kW • • • • R410A • • •

300 WHISPER ENTHALPY 47,4 - 243 kW • • • • R410A • • • •302 WHISPER ENTHALPY-T 47,4 - 243 kW • • • R410A • • • •304 WHISPER HALL 45,9 - 146 kW • • • • R410A • • • •

Rooftop units for medium crowding applications306 WISDOM 34,5 - 355 kW • • • R410A • • •308 WISDOM-T 34,7 - 357 kW • • R410A • • •

Rooftop units with heat recovery for medium crowding applications310 WISDOM-R 43,0 - 422 kW • • • R410A • • • •312 WISDOM-T-R 43,5 - 425 kW • • R410A • • • •

WET line units for water loop systems314 WET-RMT 7,2 - 34,4 kW • • R410A • •316 WET ENTHALPY 50,6 - 262 kW • • • R410A • • •318 WET-RTF 37,2 - 396 kW • • • R410A • •320 WET-RTF-R 44,8 - 468 kW • • • R410A • • •

Packaged

Page 16: Products Guide V01 - ParagonEfficient project management thanks to Climaveneta as unique project leader. Complete and specialized Organization Climaveneta qualifies itself for the

14

ONIC - RERO EO

Page 17: Products Guide V01 - ParagonEfficient project management thanks to Climaveneta as unique project leader. Complete and specialized Organization Climaveneta qualifies itself for the

15

ESIDENTIALhydronic - residential

hyd

ron

icre

sid

en

tial

Page 18: Products Guide V01 - ParagonEfficient project management thanks to Climaveneta as unique project leader. Complete and specialized Organization Climaveneta qualifies itself for the

16

Main accessoriesRemovable metal mesh water filter kit

Rubber anti-vibration mounting kit

Coil protection grid for models 0071÷0121

Additional circulating pump kit for models 0041÷0061

External main switch kit

External buffer tank and hydronic connecting kit

HSW10 remote keyboard

FeaturesCoil protection grid for models 0011÷0061.

Structure and base in hot-dip galvanised steel with epoxy powder paint finish.High-efficiency plate exchangers in AISI 316 stainless steel with low pressure drops, fitted with heating element for frost protection.

External access to control with anti-tamper device.

Finned coils made with copper pipes and aluminium fins with large exchange surface area, tested for leaks with dried air at 30 bar.

User interface with display.

Phase sequence controller for models 0071÷0121

Differential pressure switch.

Air vent valve.

The hydronic circuit on the FF models includes:

Circulating pump for models 0011÷0061.

Multistage centrifugal pump for models 0071÷0121.

Expansion tank.

Safety valve.

Manual filling assembly.

Pressure gauge.

Drain valve.

VersionsFF base version, with built-in hydronic kit

FF-SL super-low noise version, with built-in hydronic kit

FFT base version without hydronic kit

FFT-SL super-low noise version without hydronic kit

CommandsFull Floating featuresThe new generation electronic controller allows to manage the chiller by using the Full Floating technology, designed by Climaveneta for improving the system´s efficiency for the fans (Floating Fans), for the circulating pump (Floating Flow) and finally for the working temperature (Floating Setpoint). This also allows to achieve all the following benefits: improvement of efficiency in both standard and extreme conditions, much lower operating noise in part load conditions, lower installation time, lower time for system set-up, broader operating limits, faster transient after defrosts.

Hydronic - residential

BRAT 0011÷0121

Chillers, air source for outdoor installation

4,9 - 32,9 kWUnit DescriptionBRAT is the Climaveneta range of air-cooled chillers with gas R410A. It is an outdoor unit with axial fans, hermetic Scroll compressors and Full Floating technology. The latter is an intelligent electronic unit providing the perfect answer to residential market requirements: compactness, ease of installation and quietness.

Page 19: Products Guide V01 - ParagonEfficient project management thanks to Climaveneta as unique project leader. Complete and specialized Organization Climaveneta qualifies itself for the

17

Note:

1 Evaporator water (in/out) 12/7°C, condenser air (in) 35°C, based on Eurovent standard

2 Noise level measured at 1 m in open field conditions

Models 0041 0051 0061 0071 0091 0101 0121COOLING ONLY VERSIONNominal Cooling capacity (1) kW 11,4 13,2 15,4 19,3 21,9 26,4 32,9Total absorbed power (1) kW 4,20 4,70 5,20 6,80 7,80 8,70 11,1Absorbed current A 8,38 8,98 9,68 14,6 15,8 21,7 24,6EER 2,71 2,81 2,96 2,84 2,81 3,03 2,96ESEER 3,30 3,25 3,51 3,37 3,28 3,47 3,41Nominal water flow m3/h 2 2,30 2,70 3,30 3,80 4,50 5,70Operational weight kg 125 145 155 245 250 320 325No. fans N. 2 2 2 1 1 2 2Useful head kPa 43 35 32 116 90 130 108Airflow m3/h 6800 6800 6400 9800 9800 14000 14000Compressor type SCROLL SCROLL SCROLL SCROLL SCROLL SCROLL SCROLLRefrigerant R410A R410A R410A R410A R410A R410A R410AHydraulic connections inches 1” 1/4 1” 1/4 1” 1/4 1” 1/4 1” 1/4 1” 1/4 1” 1/4Sound pressure level (2) dB(A) 58 58 58 65 65 65 65Sound power dB(A) 69 69 69 76 76 79 79Electrical power supply V-Ph~Hz 400V-3N~50Hz 400V-3N~50Hz 400V-3N~50Hz 400V-3N~50Hz 400V-3N~50Hz 400V-3N~50Hz 400V-3N~50HzDIMENSIONL mm 900 900 900 1450 1450 1450 1450H mm 1240 1240 1390 1200 1200 1700 1700P mm 370 370 420 550 550 550 550

BRAT / FFModels 0011 0021 0025 0031 0041 0021 0025 0031COOLING ONLY VERSIONNominal Cooling capacity (1) kW 4,90 5,60 6,90 8,60 11 5,60 7 8,70Total absorbed power (1) kW 1,90 2,10 2,50 3,40 4,10 2 2,40 3,10Absorbed current A 9,24 9,84 12,4 15,6 18,6 4,24 4,44 5,94EER 2,58 2,67 2,76 2,53 2,68 2,80 2,92 2,81ESEER 3,11 3,35 3,33 3,28 3,17 3,37 3,37 3,34Nominal water flow m3/h 0,80 1 1,20 1,50 1,90 1 1,20 1,50Operational weight kg 80 85 100 105 125 85 100 105No. fans N. 1 1 1 1 2 1 1 1Useful head kPa 49 46 42 41 43 46 42 41Airflow m3/h 2400 3500 3500 4200 6800 3500 3500 4200Compressor type SCROLL SCROLL SCROLL SCROLL SCROLL SCROLL SCROLL SCROLLRefrigerant R410A R410A R410A R410A R410A R410A R410A R410AHydraulic connections inches 3/4” 3/4” 3/4” 3/4” 1” 1/4 3/4” 3/4” 3/4”Sound pressure level (2) dB(A) 54 55 55 55 58 55 55 55Sound power dB(A) 65 66 66 66 69 66 66 66Electrical power supply V-Ph~Hz 230V~50Hz 230V~50Hz 230V~50Hz 230V~50Hz 230V~50Hz 400V-3N~50Hz 400V-3N~50Hz 400V-3N~50HzDIMENSIONL mm 900 900 900 900 900 900 900 900H mm 640 640 940 940 1240 640 940 940P mm 370 370 370 370 370 370 370 370

COOLING

r HFCR-410A

SCROLLAXIALPLATES

Page 20: Products Guide V01 - ParagonEfficient project management thanks to Climaveneta as unique project leader. Complete and specialized Organization Climaveneta qualifies itself for the

18

Note:

1 Evaporator water (in/out) 12/7°C, condenser air (in) 35°C, based on Eurovent standard

2 Noise level measured at 1 m in open field conditions

Models 0041 0051 0061 0071 0091 0101 0121COOLING ONLY VERSIONNominal Cooling capacity (1) kW 11,4 13,2 15,4 19,3 21,9 26,4 32,9Total absorbed power (1) kW 4,20 4,70 5,20 6,80 7,80 8,70 11,1Absorbed current A 8,38 8,98 9,68 14,6 15,8 21,7 24,6EER 2,71 2,81 2,96 2,84 2,81 3,03 2,96ESEER 3,30 3,25 3,51 3,37 3,28 3,47 3,41Nominal water flow m3/h 2 2,30 2,70 3,30 3,80 4,50 5,20Operational weight kg 125 145 155 245 250 320 325No. fans N. 2 2 2 1 1 2 2Airflow m3/h 6800 6800 6400 9800 9800 14000 14000Compressor type SCROLL SCROLL SCROLL SCROLL SCROLL SCROLL SCROLLRefrigerant R410A R410A R410A R410A R410A R410A R410AHydraulic connections inches 1” 1/4 1” 1/4 1” 1/4 1” 1/4 1” 1/4 1” 1/4 1” 1/4Sound pressure level (2) dB(A) 58 58 58 65 65 65 65Sound power dB(A) 69 69 69 76 76 79 79Electrical power supply V-Ph~Hz 400V-3N~50Hz 400V-3N~50Hz 400V-3N~50Hz 400V-3N~50Hz 400V-3N~50Hz 400V-3N~50Hz 400V-3N~50HzDIMENSIONL mm 900 900 900 1450 1450 1450 1450H mm 1240 1240 1390 1200 1200 1700 1700P mm 370 370 420 550 550 550 550

BRAT / FFTModels 0011 0021 0025 0031 0041 0021 0025 0031COOLING ONLY VERSIONNominal Cooling capacity (1) kW 4,90 5,60 6,90 8,60 11 5,60 7 8,70Total absorbed power (1) kW 1,90 2,10 2,50 3,40 4,10 2 2,40 3,10Absorbed current A 9,24 9,84 12,4 15,6 18,7 4,24 4,44 5,94EER 2,58 2,67 2,76 2,53 2,68 2,80 2,92 2,81ESEER 3,11 3,35 3,33 3,28 3,17 3,37 3,37 3,34Nominal water flow m3/h 0,80 1 1,20 1,50 1,90 1 1,20 1,50Operational weight kg 80 85 100 105 125 85 100 105No. fans N. 1 1 1 1 2 1 1 1Airflow m3/h 2400 3500 3500 4200 6800 3500 3500 4200Compressor type SCROLL SCROLL SCROLL SCROLL SCROLL SCROLL SCROLL SCROLLRefrigerant R410A R410A R410A R410A R410A R410A R410A R410AHydraulic connections inches 3/4” 3/4” 3/4” 3/4” 1” 1/4 3/4” 3/4” 3/4”Sound pressure level (2) dB(A) 54 55 55 55 58 55 55 55Sound power dB(A) 65 66 66 66 69 66 66 66Electrical power supply V-Ph~Hz 230V~50Hz 230V~50Hz 230V~50Hz 230V~50Hz 230V~50Hz 400V-3N~50Hz 400V-3N~50Hz 400V-3N~50HzDIMENSIONL mm 900 900 900 900 900 900 900 900H mm 640 640 940 940 1240 640 940 940P mm 370 370 370 370 370 370 370 370

Page 21: Products Guide V01 - ParagonEfficient project management thanks to Climaveneta as unique project leader. Complete and specialized Organization Climaveneta qualifies itself for the

19

Note:

1 Evaporator water (in/out) 12/7°C, condenser air (in) 35°C, based on Eurovent standard

2 Noise level measured at 1 m in open field conditions

BRAT / FF-SLModels 0071 0091 0101 0121COOLING ONLY VERSIONNominal Cooling capacity (1) kW 19,3 21,9 26,4 32,9Total absorbed power (1) kW 6,50 7,50 7,95 10,4Absorbed current A 12,4 13,6 18,6 21,5EER 2,96 2,92 3,32 3,18ESEER 3,51 3,41 3,85 3,66Nominal water flow m3/h 3,30 3,80 4,50 5,70Operational weight kg 245 250 320 325No. fans N. 2 2 3 3Useful head kPa 116 90 130 108Airflow m3/h 7000 7000 10500 10500Compressor type SCROLL SCROLL SCROLL SCROLLRefrigerant R410A R410A R410A R410AHydraulic connections inches 1” 1/4 1” 1/4 1” 1/4 1” 1/4Sound pressure level (2) dB(A) 62 62 63 63Sound power dB(A) 73 73 74 74Electrical power supply V-Ph~Hz 400V-3N~50Hz 400V-3N~50Hz 400V-3N~50Hz 400V-3N~50HzDIMENSIONL mm 1450 1450 1450 1450H mm 1200 1200 1700 1700P mm 550 550 550 550

Note:

1 Evaporator water (in/out) 12/7°C, condenser air (in) 35°C, based on Eurovent standard

2 Noise level measured at 1 m in open field conditions

BRAT / FFT-SLModels 0071 0091 0101 0121COOLING ONLY VERSIONNominal Cooling capacity (1) kW 19,3 21,9 26,4 32,9Total absorbed power (1) kW 6,50 7,50 7,95 10,4Absorbed current A 12,4 13,6 18,6 21,5EER 2,96 2,92 3,32 3,18ESEER 3,51 3,41 3,85 3,66Nominal water flow m3/h 3,30 3,80 4,50 5,70Operational weight kg 245 250 320 325No. fans N. 2 2 3 3Airflow m3/h 7000 7000 10500 10500Compressor type SCROLL SCROLL SCROLL SCROLLRefrigerant R410A R410A R410A R410AHydraulic connections inches 1” 1/4 1” 1/4 1” 1/4 1” 1/4Sound pressure level (2) dB(A) 62 62 63 63Sound power dB(A) 73 73 74 74Electrical power supply V-Ph~Hz 400V-3N~50Hz 400V-3N~50Hz 400V-3N~50Hz 400V-3N~50HzDIMENSIONL mm 1450 1450 1450 1450H mm 1200 1200 1700 1700P mm 550 550 550 550

Dimension

P

L

H

PL

HH

L

P

Page 22: Products Guide V01 - ParagonEfficient project management thanks to Climaveneta as unique project leader. Complete and specialized Organization Climaveneta qualifies itself for the

20

Main accessoriesRubber anti-vibration mounting kit

Removable metal mesh water filter kit

Kit for connecting the KMC keyboard

Coil protection grids

KMC keyboard for modular system

Remote control kit

Features Structure and base in hot-dip galvanised steel with epoxy powder paint finish.High-efficiency plate exchangers in AISI 316 stainless steel with low pressure drops, fitted with heating element for frost protection.

External access to control with anti-tamper device.

Finned coils made with copper pipes and aluminium fins with large exchange surface area, tested for leaks with dried air at 30 bar.

User interface with display.

Electronic expansion valve

Available water pipe fittings in case of installation under appliance

Differential pressure switch.

Drain valve.

The hydronic circuit on the FF models includes:

Multistage centrifugal pump

Air vent valve.

Expansion tank.

Safety valve.

Pressure gauge.

VersionsFF base version, with built-in hydronic kit

FFT base version without hydronic kit

CommandsModular designMICS features an innovative design that optimises the possibilities of connecting up several units, reducing the necessary access space to a minimum and thereby the overall size of the units.

Increasingly better capacity controlThe possibility of controlling up to six units as a single product means that MICS can increase the number of available control steps, thereby ensuring practically perfect adaptation to the real heat load trend.

Keyboard Master ControlKMC is the central control of the cascade modules. Its main function is to supervise operation of all the modules, making them operate synergically. As a user interface it has a graphic display and a keypad for navigating in the pull-down menus.

Full Floating technologyThe full floating technology with automatic control of the airflow rate, water flow rate and water temperature gains a new function: Flex Energy, used to manage the capacity control steps in linear or alternating sequence in installations with several modules.

Hydronic - residential

MICS 0072÷0182

Modular chillers, air source for outdoor installation

18,2 - 44,7 kWUnit DescriptionMICS is the Climaveneta range of air-cooled liquid chillers. They are outdoor units with axial fans, hermetic Scroll compressors and Full Floating technology. The latter is an intelligent electronic unit providing the perfect answer to residential market requirements: compactness, ease of installation and quietness.

Page 23: Products Guide V01 - ParagonEfficient project management thanks to Climaveneta as unique project leader. Complete and specialized Organization Climaveneta qualifies itself for the

21

Note:

1 Evaporator water (in/out) 12/7°C, condenser air (in) 35°C, based on Eurovent standard

2 Noise level measured at 1 m in open field conditions

MICS / FFModels 0072 0092 0122 0152 0182COOLING ONLY VERSIONNominal Cooling capacity (1) kW 18,2 23 31,8 39,4 44,7Total absorbed power (1) kW 6,50 9,30 10,7 13,5 15,5EER 2,80 2,47 2,97 2,92 2,88ESEER 4,05 3,93 3,98 4,12 4,17Absorbed current A 14 19,1 22,2 27,8 31,5Nominal water flow m3/h 3,10 4 5,50 6,80 7,70Operational weight kg 310 330 410 450 480No. fans N. 1 1 2 2 2No. Compressors N. 2 2 2 2 2Airflow m3/h 9000 9000 18000 18000 18000Compressor type SCROLL SCROLL SCROLL SCROLL SCROLLHydraulic connections inches 1”1/4 1”1/4 1”1/4 1”1/4 1”1/4Refrigerant R410A R410A R410A R410A R410ASound pressure level (2) dB(A) 68 68 71 71 71Sound power dB(A) 80 80 83 83 83Electrical power supply V-Ph~Hz 400V-3N~50Hz 400V-3N~50Hz 400V-3N~50Hz 400V-3N~50Hz 400V-3N~50HzDIMENSIONL mm 1040 1040 1630 1630 1630H mm 1630 1630 1630 1630 1630P mm 790 790 790 790 790

COOLING

r HFCR-410A

SCROLLAXIALPLATES

Note:

1 Evaporator water (in/out) 12/7°C, condenser air (in) 35°C, based on Eurovent standard

2 Noise level measured at 1 m in open field conditions

MICS / FFTModels 0072 0092 0122 0152 0182COOLING ONLY VERSIONNominal Cooling capacity (1) kW 18,2 23 31,8 39,4 44,7Total absorbed power (1) kW 6,50 9,30 10,7 13,5 15,5EER 2,80 2,47 2,97 2,92 2,88ESEER 4,05 3,93 3,98 4,12 4,17Absorbed current A 14 19,1 22,2 27,8 31,5Nominal water flow m3/h 3,10 4 5,50 6,80 7,70Operational weight kg 310 330 410 450 480No. fans N. 1 1 2 2 2No. Compressors N. 2 2 2 2 2Airflow m3/h 9000 9000 18000 18000 18000Compressor type SCROLL SCROLL SCROLL SCROLL SCROLLHydraulic connections inches 1”1/4 1”1/4 1”1/4 1”1/4 1”1/4Refrigerant R410A R410A R410A R410A R410ASound pressure level (2) dB(A) 68 68 71 71 71Sound power dB(A) 80 80 83 83 83Electrical power supply V-Ph~Hz 400V-3N~50Hz 400V-3N~50Hz 400V-3N~50Hz 400V-3N~50Hz 400V-3N~50HzDIMENSIONL mm 1040 1040 1630 1630 1630H mm 1630 1630 1630 1630 1630P mm 790 790 790 790 790

Dimension

LP

H

Page 24: Products Guide V01 - ParagonEfficient project management thanks to Climaveneta as unique project leader. Complete and specialized Organization Climaveneta qualifies itself for the

22

Main accessoriesHSW10 remote keyboard

External buffer tank and hydronic connecting kit

External main switch kit

Additional circulating pump kit for models 0041÷0061

Rubber anti-vibration mounting kit

Removable metal mesh water filter kit

FeaturesCoil protection grid for all models.

Structure and base in hot-dip galvanised steel with epoxy powder paint finish.High-efficiency plate exchangers in AISI 316 stainless steel with low pressure drops, fitted with heating element for frost protection.

External access to control with anti-tamper device.

Finned coils made with copper pipes and aluminium fins with large exchange surface area, tested for leaks with dried air at 30 bar.

User interface with display.

The circuit includes:

Air vent valve.

Water circulator.

Differential pressure switch.

Expansion tank.

Safety valve.

Pressure gauge.

Manual filling assembly.

Drain valve.

CommandsFull Floating featuresThe new generation electronic controller allows to manage the chiller by using the Full Floating technology, designed by Climaveneta for improving the system´s efficiency for the fans (Floating Fans), for the circulating pump (Floating Flow) and finally for the working temperature (Floating Setpoint). This also allows to achieve all the following benefits: improvement of efficiency in both standard and extreme conditions, much lower operating noise in part load conditions, lower installation time, lower time for system set-up, broader operating limits, faster transient after defrosts.

Hydronic - residential

BRA 0011÷0061

Chillers, air source for indoor installation

4,9 - 15,4 kWUnit DescriptionBRA is the Climaveneta range of air-cooled liquid chillers with R410A refrigerant. They are fitted with hermetic Scroll compressors and Full Floating technology. The latter is an intelligent electronic unit providing the perfect answer to residential market requirements: compactness, ease of installation and quietness.

VersionsFF base version, with built-in hydronic kit

FFT base version without hydronic kit

Page 25: Products Guide V01 - ParagonEfficient project management thanks to Climaveneta as unique project leader. Complete and specialized Organization Climaveneta qualifies itself for the

23

Note:

1 Evaporator water (in/out) 12/7°C, condenser air (in) 35°C, based on Eurovent standard

2 Noise level measured at 1 m in open field conditions

BRA / FFModels 0011 0021 0025 0031 0041 0021 0025 0031 0041 0051 0061COOLING ONLY VERSIONNominal Cooling capacity (1) kW 4,9 5,6 6,9 8,6 11,0 5,6 7,0 8,7 11,4 13,2 15,4Total absorbed power (1) kW 2,5 2,6 3,1 4,0 5,2 2,6 3,0 3,7 5,3 5,8 6,4EER 1,96 2,15 2,23 2,15 2,11 2,15 2,33 2,35 2,15 2,28 2,41ESEER 2,24 2,48 2,68 2,60 2,39 2,54 2,76 2,70 2,48 2,53 2,78Absorbed current A 11,9 12,5 15,1 18,3 24,6 6,90 7,10 8,60 13,7 14,3 15Nominal water flow m3/h 0,80 1 1,20 1,50 1,90 1 1,20 1,50 2 2,30 2,70Useful head kPa 49 46 42 41 43 46 42 41 43 35 32Operational weight kg 100 105 115 125 165 105 115 125 165 185 195No. fans N. 1 1 1 1 2 1 1 1 2 2 2Airflow m3/h 3200 3200 3600 3600 6800 3200 3600 3600 6800 6800 6800Compressor type SCROLL SCROLL SCROLL SCROLL SCROLL SCROLL SCROLL SCROLL SCROLL SCROLL SCROLLRefrigerant R410A R410A R410A R410A R410A R410A R410A R410A R410A R410A R410AHydraulic connections inches 3/4” 3/4” 3/4” 3/4” 1”1/4 3/4” 3/4” 3/4” 1”1/4 1”1/4 1”1/4Sound pressure level (2) dB(A) 55 55 55 55 60 55 55 55 60 60 60Sound power dB(A) 68 68 68 68 71 68 68 68 71 71 71Electrical power supply V-Ph~Hz 230V~50Hz 400V-3N~50HzDIMENSIONL mm 900 900 900 900 900 900 900 900 900 900 900H mm 640 640 940 940 1240 640 940 940 1240 1240 1390P mm 580 580 580 580 580 580 580 580 580 580 630

COOLING

r HFCR-410A

SCROLLCENTRIFUGALPLATES

Dimension

P

L

H

Note:

1 Evaporator water (in/out) 12/7°C, condenser air (in) 35°C, based on Eurovent standard

2 Noise level measured at 1 m in open field conditions

BRA / FFTModelli 0011 0021 0025 0031 0041 0021 0025 0031 0041 0051 0061COOLING ONLY VERSIONNominal Cooling capacity (1) kW 4,9 5,6 6,9 8,6 11 5,6 7 8,7 11,4 13,2 15,4Total absorbed power (1) kW 2,5 2,6 3,1 4 5,2 2,6 3 3,7 5,3 5,8 6,4

Absorbed current A 1,96 2,15 2,23 2,15 2,11 2,15 2,33 2,35 2,15 2,28 2,41

EER 2,24 2,48 2,68 2,6 2,39 2,54 2,76 2,7 2,48 2,53 2,78ESEER 11,9 12,5 15,1 18,3 24,6 6,9 7,1 8,6 13,71 14,3 15Nominal water flow m3/h 0,80 1 1,20 1,50 1,90 1 1,20 1,50 2 2,3 2,7Operational weight kg 100 105 115 125 165 105 115 125 165 185 195No. fans N. 1 1 1 1 2 1 1 1 2 2 2Airflow m3/h 3200 3200 3600 3600 6800 3200 3600 3600 6800 6800 6800Compressor type SCROLL SCROLL SCROLL SCROLL SCROLL SCROLL SCROLL SCROLL SCROLL SCROLL SCROLLRefrigerant R410A R410A R410A R410A R410A R410A R410A R410A R410A R410A R410AHydraulic connections inches 3/4” 3/4” 3/4” 3/4” 1” 1/4 3/4” 3/4” 3/4” 1” 1/4 1” 1/4 1” 1/4Sound pressure level (2) dB(A) 55 55 55 55 60 55 55 55 60 60 60Sound power dB(A) 68 68 68 68 71 68 68 68 71 71 71Electrical power supply V-Ph~Hz 230V~50Hz 400V-3N~50HzDIMENSIONL mm 900 900 900 900 900 900 900 900 900 900 900H mm 640 640 940 940 1240 640 940 940 1240 1240 1390P mm 580 580 580 580 580 580 580 580 580 580 630

Page 26: Products Guide V01 - ParagonEfficient project management thanks to Climaveneta as unique project leader. Complete and specialized Organization Climaveneta qualifies itself for the

24

Main accessoriesRubber anti-vibration mounting kit

Removable metal mesh water filter kit

Coil protection grids

Remote control kit

Features Structure and base in hot-dip galvanised steel with epoxy powder paint finish.High-efficiency plate exchangers in AISI 316 stainless steel with low pressure drops, fitted with heating element for frost protection.

External access to control with anti-tamper device.

Finned coils made with copper pipes and aluminium fins with large exchange surface area, tested for leaks with dried air at 30 bar.

User interface with display.

Electronic expansion valve

Available water pipe fittings in case of installation under appliance

The circuit includes:

Multistage centrifugal pump

Air vent valve.

Differential pressure switch.

Expansion tank.

Safety valve.

Pressure gauge.

Drain valve.

VersionsFF base version, with built-in hydronic kit

CommandsFull Floating technologyThe new generation electronic controller allows to manage the chiller by using the Full Floating technology, designed by Climaveneta for improving the system´s efficiency for the fans (Floating Fans), for the circulating pump (Floating Flow) and finally for the working temperature (Floating Setpoint). This also allows to achieve all the following benefits: improvement of efficiency in both standard and extreme conditions, much lower operating noise in part load conditions, lower installation time, lower time for system set-up, broader operating limits, faster transient after defrosts.

Hydronic - residential

MICS-C 0072÷0122

Chillers, air source for indoor installation

18,2 - 31,8 kWUnit DescriptionMICS-C is the Climaveneta range of air-cooled liquid chillers with gas R410A. They are fitted with hermetic Scroll compressors and Full Floating technology. The latter is an intelligent electronic unit providing the perfect answer to residential market requirements: compactness, ease of installation and quietness.

Page 27: Products Guide V01 - ParagonEfficient project management thanks to Climaveneta as unique project leader. Complete and specialized Organization Climaveneta qualifies itself for the

25

Note:

1 Evaporator water (in/out) 12/7°C, condenser air (in) 35°C, based on Eurovent standard

2 Noise level measured at 1 m in open field conditions

MICS-C / FFModels 0072 0092 0122COOLING ONLY VERSIONNominal Cooling capacity (1) kW 18,2 23 31,8Total absorbed power (1) kW 6,50 9,31 10,7EER 2,80 2,47 2,97ESEER 4,05 3,93 3,98Absorbed current A 16,1 19,8 27,3Nominal water flow m3/h 3,10 4 5,50Operational weight kg 330 350 450No. fans N. 1 1 2No. Compressors N. 2 2 2Airflow m3/h 9000 9000 18000Compressor type SCROLL SCROLL SCROLLHydraulic connections inches 1”1/4 1”1/4 1”1/4Refrigerant R410A R410A R410ASound pressure level (2) dB(A) 74 74 77Sound power dB(A) 86 86 89Electrical power supply V-Ph~Hz 400V-3N~50Hz 400V-3N~50Hz 400V-3N~50HzDIMENSIONL mm 1040 1040 1630H mm 2000 2000 2000P mm 790 790 790

COOLING

r HFCR-410A

SCROLLCENTRIFUGALPLATES

Dimension

L P

H

Page 28: Products Guide V01 - ParagonEfficient project management thanks to Climaveneta as unique project leader. Complete and specialized Organization Climaveneta qualifies itself for the

26

Main accessoriesRemovable metal mesh water filter kit

HSW10 remote keyboard

Features Structure and base in hot-dip galvanised steel with epoxy powder paint finish.High-efficiency plate exchangers in AISI 316 stainless steel with low pressure drops (exchanger on plant side fitted with heating element for frost protection).

External access to control with anti-tamper device.

The safety of the unit is guaranteed by a door lock isolator on the electrical power switchboard and by active protection devices on the main components.

The circuit includes:

Modulating valve to reduce water consumptions (source side, FF versions only).

Circulating pump (plant side, FF versions only).

Air vent valve (plant side).

Expansion vessel (plant side).

Safety valve (plant side).

Differential pressure switch on plant circuit only.

Drain valve on both plant and source circuits.

VersionsFF base version, with built-in hydronic kit

FFT base version without hydronic kit

CommandsFloating SetOnce ever y 3 minutes an algorithm automatically optimises the water set point in relation to the compressor operating time and the temperatures of the water in the system. he water storage tank is no longer indispensable because it is compensated by the Floating Set function, with resulting reduction in: size; weight; installation times; system setting-up times.

Floating FlowThe controller manages the modulation of the active components (pump and electronic flow valve) through pressure transducers and temperature sensors. The performance of the unit may thus be optimised for different operating conditions, such as traditional fan coil system and panel heating system, ensuring: broader operating limits; easier start-up of installations with both high and low water temperatures; faster system setup.

Hydronic - residential

BRH 0011÷0121

Chiller, water source

5,5 - 35,1 kWUnit DescriptionBRH is a range of water-source liquid chillers operating with R410A refrigerant. These are indoor units with hermetic Scroll compressors and Full Floating technology. The latter is an intelligent electronic unit providing the perfect answer to residential market requirements: compactness, ease of installation and quietness.

Page 29: Products Guide V01 - ParagonEfficient project management thanks to Climaveneta as unique project leader. Complete and specialized Organization Climaveneta qualifies itself for the

27

Note:

1 Evaporator water (in/out) = 12/7°C, condenser water (in/out) = 30/35°C, based on Eurovent Standard

2 Noise level measured at 1 m in open field conditions

Models 0041 0051 0061 0071 0091 0101 0121COOLING ONLY VERSIONNominal Cooling capacity (1) kW 12,4 13,9 16,5 20,8 24 27,3 35,1Total power input (1) kW 3,20 3,80 4 5,10 5,80 6,80 8,40EER 3,88 3,66 4,13 4,08 4,14 4,01 4,18ESEER 4,28 4,22 4,74 4,62 4,84 4,55 4,59Water flow rate plant side (1) m3/h 2 2,30 2,70 3,40 3,90 4,50 5,70Absorbed current A 7,40 8,10 8,80 12,2 13,4 16,1 19,2Operational weight kg 160 170 175 220 230 235 250Compressor type SCROLL SCROLL SCROLL SCROLL SCROLL SCROLL SCROLLRefrigerant R410A R410A R410A R410A R410A R410A R410AHydraulic connections inches G 1”1/4 G 1”1/4 G 1”1/4 G 1”1/4 G 1”1/4 G 1”1/4 G 1”1/4Sound pressure level (2) dB(A) 47 47 48 55 55 59 59Sound power dB(A) 58 58 59 66 66 70 70Electrical power supply V-Ph~Hz 400V-3N~50Hz 400V-3N~50Hz 400V-3N~50Hz 400V-3N~50Hz 400V-3N~50Hz 400V-3N~50Hz 400V-3N~50HzDIMENSIONL mm 560 560 560 680 680 680 680H mm 980 980 980 1150 1150 1150 1150P mm 575 575 575 780 780 780 780

BRH / FFModels 0011 0021 0025 0031 0041 0021 0025 0031COOLING ONLY VERSIONNominal Cooling capacity (1) kW 5,50 5,90 7,60 9,20 11,9 5,90 7,70 9,30Total power input (1) kW 1,50 1,70 2 2,60 3,20 1,60 1,90 2,40EER 3,67 3,47 3,80 3,54 3,72 3,69 4,05 3,88ESEER 4,23 3,92 4,47 4,15 4,10 4 4,61 4,38Water flow rate plant side (1) m3/h 0,90 1 1,20 1,50 1,90 1 1,30 1,50Absorbed current A 7,50 8 8,90 12,3 15,6 4,60 5 6,10Operational weight kg 148 148 150 152 160 148 150 152Compressor type SCROLL SCROLL SCROLL SCROLL SCROLL SCROLL SCROLL SCROLLRefrigerant R410A R410A R410A R410A R410A R410A R410A R410AHydraulic connections inches G 3/4” G 3/4” G 3/4” G 3/4” G 1”1/4 G 3/4” G 3/4” G 3/4”Sound pressure level (2) dB(A) 41 41 42 42 47 41 42 42Sound power dB(A) 52 52 53 53 58 52 53 53Electrical power supply V-Ph~Hz 230V~50Hz 230V~50Hz 230V~50Hz 230V~50Hz 230V~50Hz 400V-3N~50Hz 400V-3N~50Hz 400V-3N~50HzDIMENSIONL mm 560 560 560 560 560 560 560 560H mm 980 980 980 980 980 980 980 980P mm 575 575 575 575 575 575 575 575

COOLING

r HFCR-410A

SCROLLPLATES

Page 30: Products Guide V01 - ParagonEfficient project management thanks to Climaveneta as unique project leader. Complete and specialized Organization Climaveneta qualifies itself for the

28

Note:

1 Evaporator water (in/out) = 12/7°C, condenser water (in/out) = 30/35°C, based on Eurovent Standard

2 Noise level measured at 1 m in open field conditions

Models 0041 0051 0061 0071 0091 0101 0121COOLING ONLY VERSIONNominal Cooling capacity (1) kW 12,4 13,9 16,5 20,8 24 27,3 35,1Total power input (1) kW 3,20 3,80 4 5,10 5,80 6,80 8,40EER 3,88 3,66 4,13 4,08 4,14 4,01 4,18ESEER 4,28 4,22 4,74 4,62 4,84 4,55 4,59Water flow rate plant side (1) m3/h 2 2,30 2,70 3,40 3,90 4,50 5,70Absorbed current A 7,40 8,10 8,80 12,2 13,4 16,1 19,2Operational weight kg 160 170 175 220 230 235 250Compressor type SCROLL SCROLL SCROLL SCROLL SCROLL SCROLL SCROLLRefrigerant R410A R410A R410A R410A R410A R410A R410AHydraulic connections inches G 1”1/4 G 1”1/4 G 1”1/4 G 1”1/4 G 1”1/4 G 1”1/4 G 1”1/4Sound pressure level (2) dB(A) 47 47 48 55 55 59 59Sound power dB(A) 58 58 59 66 66 70 70Electrical power supply V-Ph~Hz 400V-3N~50Hz 400V-3N~50Hz 400V-3N~50Hz 400V-3N~50Hz 400V-3N~50Hz 400V-3N~50Hz 400V-3N~50HzDIMENSIONL mm 560 560 560 680 680 680 680H mm 980 980 980 1150 1150 1150 1150P mm 575 575 575 780 780 780 780

BRH / FFTModels 0011 0021 0025 0031 0041 0021 0025 0031COOLING ONLY VERSIONNominal Cooling capacity (1) kW 5,50 5,90 7,60 9,20 11,9 5,90 7,70 9,30Total power input (1) kW 1,50 1,70 2 2,60 3,20 1,60 1,90 2,40EER 3,67 3,47 3,80 3,54 3,72 3,69 4,05 3,88ESEER 4,23 3,92 4,47 4,15 4,10 4 4,61 4,38Water flow rate plant side (1) m3/h 0,90 1 1,20 1,50 1,90 1 1,30 1,50Absorbed current A 7,50 8 8,90 12,3 15,6 4,60 5 6,10Operational weight kg 148 148 150 152 160 148 150 152Compressor type SCROLL SCROLL SCROLL SCROLL SCROLL SCROLL SCROLL SCROLLRefrigerant R410A R410A R410A R410A R410A R410A R410A R410AHydraulic connections inches G 3/4” G 3/4” G 3/4” G 3/4” G 1”1/4 G 3/4” G 3/4” G 3/4”Sound pressure level (2) dB(A) 41 41 42 42 47 41 42 42Sound power dB(A) 52 52 53 53 58 52 53 53Electrical power supply V-Ph~Hz 230V~50Hz 230V~50Hz 230V~50Hz 230V~50Hz 230V~50Hz 400V-3N~50Hz 400V-3N~50Hz 400V-3N~50HzDIMENSIONL mm 560 560 560 560 560 560 560 560H mm 980 980 980 980 980 980 980 980P mm 575 575 575 575 575 575 575 575

Dimension

L P

H

Page 31: Products Guide V01 - ParagonEfficient project management thanks to Climaveneta as unique project leader. Complete and specialized Organization Climaveneta qualifies itself for the

29

Page 32: Products Guide V01 - ParagonEfficient project management thanks to Climaveneta as unique project leader. Complete and specialized Organization Climaveneta qualifies itself for the

30

Main accessoriesBuffer tank plus pump

Hydronic kit plus pump

Removable metal mesh water filter kit

Modulating pump kit

Control board for the modulating pump kit

Features Structure and base in hot-dip galvanised steel with epoxy powder paint finish.High-efficiency plate exchangers in AISI 316 stainless steel with low pressure drops, fitted with heating element for frost protection.

External access to control with anti-tamper device.

Differential pressure switch.

The remote condenser may be installed up to a distance of 50 metres from the cooling unit. The safety of the unit is guaranteed by a door lock isolator on the electrical power switchboard and by active protection devices on the main components.

VersionsFF base version, with built-in hydronic kit

CommandsFull Floating featuresOnce every 3 minutes an algorithm automatically optimises the water set point in relation to the compressor operating time and the temperatures of the water in the system. The water storage tank is no longer indispensable because it is compensated by the Floating Set function, with resulting reduction in: size; weight; installation times; system setting-up times.

Hydronic - residential

HE FF 0011÷0121

Condenserless units

4,7 - 32,4 kWUnit DescriptionHH FF is the Climaveneta range of cooling units. These are indoor units that may be combined with remote outdoor condensers to guarantee maximum flexibility and compliance with any architectural restriction. These units have hermetic Scroll compressors and Full Floating technology. The latter is an intelligent electronic unit providing the perfect answer to residential market requirements: compactness, ease of installation and quietness.

Page 33: Products Guide V01 - ParagonEfficient project management thanks to Climaveneta as unique project leader. Complete and specialized Organization Climaveneta qualifies itself for the

31

Note:

1 Evaporator water (in/out): 12/7°C; Condensation temperature: 47°C.

2 Noise level measured at 1 m in open field conditions

Models 0041 0051 0061 0071 0091 0101 0121COOLING ONLY VERSIONNominal Cooling capacity (1) kW 10,5 12,5 15 19,1 22,2 26,8 32,4Total absorbed power (1) kW 3,40 4,20 4,90 6,30 7,80 8,90 10,9EER 3,06 2,97 3,07 3,03 2,86 3 2,96ESEER 3,54 3,36 3,81 3,45 3,22 3,43 3,32Absorbed current A 6,20 7,60 8,81 12 14,1 16,2 18,9Water flow in cooling m3/h 1,90 2,30 2,80 3,40 4,10 4,80 5,90Pressure drop kPa 19 20 20 23 22 23 23Operational weight kg 85 87 90 177 180 187 190Compressor type SCROLL SCROLL SCROLL SCROLL SCROLL SCROLL SCROLLRefrigerant R407C R407C R407C R407C R407C R407C R407CHydraulic connections inches 1/2” 1/2” 1/2” 5/8” 5/8” 3/4” 3/4”Gas connection inches 3/4” 3/4” 3/4” 7/8” 7/8” 7/8” 7/8”In/out gas water fittings inches 1”1/4 1”1/4 1”1/4 1”1/4 1”1/4 1”1/4 1”1/4Sound pressure level (2) dB(A) 52 52 52 52 52 53 53Sound power dB(A) --- --- --- --- --- --- ---Electrical power supply V-Ph~Hz 400V-3N~50Hz 400V-3N~50Hz 400V-3N~50Hz 400V-3N~50Hz 400V-3N~50Hz 400V-3N~50Hz 400V-3N~50HzDIMENSIONL mm 400 400 400 600 600 600 600H mm 960 960 960 960 960 960 960P mm 450 450 450 600 600 600 600

HE FF Models 0011 0021 0025 0031 0021 0025 0031COOLING ONLY VERSIONNominal Cooling capacity (1) kW 4,70 6,10 7 8,20 6,10 7 8,20Total absorbed power (1) kW 1,60 2,10 2,50 2,90 2,10 2,40 2,90EER 2,84 2,89 2,80 2,79 2,94 2,86 2,86ESEER 3,20 3,32 3,22 3,27 3,41 3,30 3,38Absorbed current A 7,67 9,81 11,6 13,7 3,77 4,56 5,22Water flow in cooling m3/h 0,90 1,10 1,30 1,50 1,10 1,30 1,50Pressure drop kPa 22 24 26 27 24 26 27Operational weight kg 68 70 71 74 70 71 74Compressor type SCROLL SCROLL SCROLL SCROLL SCROLL SCROLL SCROLLRefrigerant R407C R407C R407C R407C R407C R407C R407CHydraulic connections inches 3/8” 3/8” 3/8” 3/8” 3/8” 3/8” 3/8”Gas connection inches 1/2” 1/2” 5/8” 5/8” 1/2” 5/8” 5/8”In/out gas water fittings inches 3/4” 3/4” 3/4” 3/4” 3/4” 3/4” 3/4”Sound pressure level (2) dB(A) 43 43 48 48 43 48 48Sound power dB(A) --- --- --- --- --- --- ---Electrical power supply V-Ph~Hz 230V~50Hz 230V~50Hz 230V~50Hz 230V~50Hz 400V-3N~50Hz 400V-3N~50Hz 400V-3N~50HzDIMENSIONL mm 400 400 400 400 400 400 400H mm 960 960 960 960 960 960 960P mm 450 450 450 450 450 450 450

COOLING

r HFCR-407C

SCROLLPLATES

Dimension

PL

H

Page 34: Products Guide V01 - ParagonEfficient project management thanks to Climaveneta as unique project leader. Complete and specialized Organization Climaveneta qualifies itself for the

32

Features Structure and base in hot-dip galvanised steel with epoxy powder paint finish.The remote condenser may be installed up to a distance of 50 metres from the cooling unit.Finned coils made with copper pipes and aluminium fins with large exchange surface area.

VersionsNHCR base version

Hydronic - residential

NHCR 0011÷0121

Remote condenser with axial fans

8,6 - 41,9 kWUnit DescriptionNHCR are remote condensers with axial fans for condenserless units.

Page 35: Products Guide V01 - ParagonEfficient project management thanks to Climaveneta as unique project leader. Complete and specialized Organization Climaveneta qualifies itself for the

33

Note:

1 The nominal capacity refers to a ∆t = 15°K.

2 Sound pressure measured at 10 m in open field conditions

NHCRModels 0011 0021 0025 0031 0041 0051 0061 0071 0091 0101 0121Nominal Cooling capacity (1) kW 8,6 8,6 17,2 17,2 17,2 18,9 25,8 28,3 28,3 37,5 41,9Fan Diameter mm 1 x 400 1 x 400 2 x 400 2 x 400 2 x 400 2 x 400 3 x 400 3 x 400 3 x 400 2 x 500 2 x 500Airflow m3/h 2283 2283 4570 4570 4570 4058 6850 6080 6080 10440 9690RPM n°/min 940 940 940 940 940 940 940 940 940 890 890Total absorbed power (1) kW 1 x 0,12 1 x 0,12 2 x 0,12 2 x 0,12 2 x 0,12 2 x 0,12 3 x 0,12 3 x 0,12 3 x 0,12 2 x 0,29 2 x 0,29Absorbed current A 1 x 0,46 1 x 0,46 2 x 0,46 2 x 0,46 2 x 0,46 2 x 0,46 3 x 0,46 3 x 0,46 3 x 0,46 2 x 1,15 2 x 1,15Current input at maximum conditions

n° x A 1 x 0,55 1 x 0,55 2 x 0,55 2 x 0,55 2 x 0,55 2 x 0,55 3 x 0,55 3 x 0,55 3 x 0,55 2 x 1,25 2 x 1,25

Electrical power supply V-Ph~Hz 230V~50Hz 230V~50Hz 230V~50Hz 230V~50Hz 230V~50Hz 230V~50Hz 230V~50Hz 230V~50Hz 230V~50Hz 230V~50Hz 230V~50HzInlet connections mm 14 14 20 20 20 22 24 28 28 35 35Outlet connections mm 12 12 18 18 18 20 22 22 22 28 28Operational weight kg 33 33 37 37 37 46 66 66 73 93 101Attacco presa pressione inch 1/4” 1/4” 1/4” 1/4” 1/4” 1/4” 1/4” 1/4” 1/4” 1/4” 1/4”No. fans N. 1 1 2 2 2 2 3 3 3 2 2COOLING ONLY VERSIONSound pressure level (2) dB(A) 35 35 38 38 38 38 40 40 40 42 42DIMENSIONL mm 780 780 1380 1380 1380 1380 1830 1830 1830 2042 2042H mm 555 555 555 555 555 555 555 555 555 828 828P mm 362 362 362 362 362 362 362 362 362 554 554

COOLING

Dimension

P

L

H

Page 36: Products Guide V01 - ParagonEfficient project management thanks to Climaveneta as unique project leader. Complete and specialized Organization Climaveneta qualifies itself for the

34

Main accessoriesRemovable metal mesh water filter kit

Rubber anti-vibration mounting kit

Condensate collecting tray for models 0071 ÷ 0121

Coil protection grid for models 0071÷0121

Additional circulating pump kit for models 0041÷0061

External main switch kit

External buffer tank and hydronic connecting kit

HSW10 remote keyboard

FeaturesCondensate collecting tray for models 0011 ÷ 0061.

Coil protection grid for models 0011÷0061.

Structure and base in hot-dip galvanised steel with epoxy powder paint finish.High-efficiency plate exchangers in AISI 316 stainless steel with low pressure drops, fitted with heating element for frost protection.

External access to control with anti-tamper device.

Finned coils made with copper pipes and aluminium fins with large exchange surface area, tested for leaks with dried air at 30 bar.

User interface with display.

Phase sequence controller for models 0071÷0121

Differential pressure switch.

Air vent valve.

The hydronic circuit on the FF models includes:

Water circulator for models 0011 ÷ 0061

Multistage centrifugal pump for models 0071 ÷ 0121.

Expansion tank.

Safety valve.

Manual filling assembly.

Pressure gauge.

Drain valve.

VersionsFF base version, with built-in hydronic kit

FF-SL super-low noise version, with built-in hydronic kit

FFT base version without hydronic kit

FFT-SL super-low noise version without hydronic kit

CommandsFull Floating featuresThe new generation electronic controller allows to manage the chiller by using the Full Floating technology, designed by Climaveneta for improving the system´s efficiency for the fans (Floating Fans), for the circulating pump (Floating Flow) and finally for the working temperature (Floating Setpoint). This also allows to achieve all the following benefits: improvement of efficiency in both standard and extreme conditions, much lower operating noise in part load conditions, lower installation time, lower time for system set-up, broader operating limits, faster transient after defrosts.

Hydronic - residential

BRAN 0011÷0121

reversible unit, air source for outdoor installation

4,6 - 35,5 kWUnit DescriptionBRAN is the Climaveneta range of air-cooled reversible heat pumps with gas R410A. They are outdoor units with axial fans, hermetic Scroll compressors and Full Floating technology. The latter is an intelligent electronic unit providing the perfect answer to residential market requirements: compactness, ease of installation and quietness.

Page 37: Products Guide V01 - ParagonEfficient project management thanks to Climaveneta as unique project leader. Complete and specialized Organization Climaveneta qualifies itself for the

35

Note:

1 Evaporator water (in/out) 12/7°C, condenser air (in) 35°C, based on Eurovent standard

2 Condenser water (in/out) 40/45°C, evaporator air (in) 7°C (r.h. 87%), based on Eurovent standard

3 Noise level measured at 1 m in open field conditions

Models 0041 0051 0061 0071 0091 0101 0121HEAT PUMP MODELNominal Cooling capacity (1) kW 10,8 12,6 14,6 18,4 20,8 25,1 31,3Total absorbed power (1) kW 4,2 4,7 5,2 6,8 7,8 8,7 11,1EER 2,57 2,68 2,81 2,71 2,67 2,88 2,82ESEER 3,13 3,08 3,33 3,20 3,12 3,36 3,24Nominal Heating power (2) kW 12,8 14,4 16,8 21,0 23,6 28,8 35,5Total absorbed power (2) kW 4,7 5,0 5,4 7,1 7,8 10,1 11,8COP 2,72 2,88 3,11 2,96 3,03 2,85 3,01Absorbed current A 9,28 9,48 9,98 15,1 15,8 24,4 25,8Nominal water flow (1) m3/h 1,90 2,20 2,50 3,20 3,60 4,30 5,40Useful head (1) kPa 43 35 32 116 90 130 108Operational weight kg 140 160 170 265 270 340 345No. fans N. 2 2 2 1 1 2 2Airflow m3/h 6800 6800 6400 9800 9800 14000 14000Compressor type SCROLL SCROLL SCROLL SCROLL SCROLL SCROLL SCROLLRefrigerant R410A R410A R410A R410A R410A R410A R410AHydraulic connections inches 1” 1/4 1” 1/4 1” 1/4 1” 1/4 1” 1/4 1” 1/4 1” 1/4Sound pressure level (3) dB(A) 58 58 58 65 65 65 65Sound power dB(A) 69 69 69 76 76 79 79Electrical power supply V-Ph~Hz 400V-3N~50Hz 400V-3N~50Hz 400V-3N~50Hz 400V-3N~50Hz 400V-3N~50Hz 400V-3N~50Hz 400V-3N~50HzDIMENSIONL mm 900 900 900 1450 1450 1450 1450H mm 1240 1240 1390 1200 1200 1700 1700P mm 370 370 420 550 550 550 550

BRAN / FFModels 0011 0021 0025 0031 0041 0021 0025 0031HEAT PUMP MODELNominal Cooling capacity (1) kW 4,6 5,4 6,6 8,2 10,4 5,3 6,7 8,2Total absorbed power (1) kW 1,9 2,1 2,5 3,4 4,1 2,0 2,4 3,1EER 2,42 2,57 2,64 2,41 2,53 2,65 2,79 2,64ESEER 2,96 3,19 3,16 3,01 3,01 3,21 3,41 3,17Nominal Heating power (2) kW 5,7 6,5 8,1 10,0 12,4 6,4 8,0 9,7Total absorbed power (2) kW 2,3 2,4 2,9 3,6 4,5 2,4 2,7 3,2COP 2,48 2,71 2,79 2,78 2,76 2,67 2,96 3,03Absorbed current A 10,6 11,3 13,9 16,1 21,2 4,84 4,94 6,14Nominal water flow (1) m3/h 0,80 0,90 1,10 1,40 1,80 0,90 1,20 1,40Useful head (1) kPa 49 46 42 41 43 46 42 41Operational weight kg 90 95 110 115 140 95 110 115No. fans N. 1 1 1 1 2 1 1 1Airflow m3/h 2400 3500 3500 4200 6800 3500 3500 4200Compressor type SCROLL SCROLL SCROLL SCROLL SCROLL SCROLL SCROLL SCROLLRefrigerant R410A R410A R410A R410A R410A R410A R410A R410AHydraulic connections inches 3/4” 3/4” 3/4” 3/4” 1” 1/4 3/4” 3/4” 3/4”Sound pressure level (3) dB(A) 54 55 55 55 58 55 55 55Sound power dB(A) 65 66 66 66 69 66 66 66Electrical power supply V-Ph~Hz 230V~50Hz 230V~50Hz 230V~50Hz 230V~50Hz 230V~50Hz 400V-3N~50Hz 400V-3N~50Hz 400V-3N~50HzDIMENSIONL mm 900 900 900 900 900 900 900 900H mm 640 640 940 940 1240 640 940 940P mm 370 370 370 370 370 370 370 370

COOLINGHEATING

r HFCR-410A

SCROLLAXIALPLATES

Page 38: Products Guide V01 - ParagonEfficient project management thanks to Climaveneta as unique project leader. Complete and specialized Organization Climaveneta qualifies itself for the

36

Note:

1 Evaporator water (in/out) 12/7°C, condenser air (in) 35°C, based on Eurovent standard

2 Condenser water (in/out) 40/45°C, evaporator air (in) 7°C (r.h. 87%), based on Eurovent standard

3 Noise level measured at 1 m in open field conditions

Models 0041 0051 0061 0071 0091 0101 0121HEAT PUMP MODELNominal Cooling capacity (1) kW 10,8 12,6 14,6 18,4 20,8 25,1 31,3Total absorbed power (1) kW 4,2 4,7 5,2 6,8 7,8 8,7 11,1EER 2,57 2,68 2,81 2,71 2,67 2,88 2,82ESEER 3,13 3,08 3,33 3,20 3,12 3,36 3,24Nominal Heating power (2) kW 12,8 14,4 16,8 21 23,6 28,8 35,5Total absorbed power (2) kW 4,70 5 5,40 7,10 7,80 10,1 11,8COP 2,72 2,88 3,11 2,96 3,03 2,85 3,01Absorbed current A 9,28 9,48 9,98 15,1 15,8 24,4 25,8Nominal water flow (1) m3/h 1,90 2,20 2,50 3,20 3,60 4,30 5,40Operational weight kg 140 160 170 265 270 340 345No. fans N. 2 2 2 1 1 2 2Airflow m3/h 6800 6800 6400 9800 9800 14000 14000Compressor type SCROLL SCROLL SCROLL SCROLL SCROLL SCROLL SCROLLRefrigerant R410A R410A R410A R410A R410A R410A R410AHydraulic connections inches 1” 1/4 1” 1/4 1” 1/4 1” 1/4 1” 1/4 1” 1/4 1” 1/4Sound pressure level (3) dB(A) 58 58 58 65 65 65 65Sound power dB(A) 69 69 69 76 76 79 79Electrical power supply V-Ph~Hz 400V-3N~50Hz 400V-3N~50Hz 400V-3N~50Hz 400V-3N~50Hz 400V-3N~50Hz 400V-3N~50Hz 400V-3N~50HzDIMENSIONL mm 900 900 900 1450 1450 1450 1450H mm 1240 1240 1390 1200 1200 1700 1700P mm 370 370 420 550 550 550 550

BRAN / FFTModels 0011 0021 0025 0031 0041 0021 0025 0031HEAT PUMP MODELNominal Cooling capacity (1) kW 4,6 5,4 6,6 8,2 10,4 5,3 6,7 8,2Total absorbed power (1) kW 1,9 2,1 2,5 3,4 4,1 2,0 2,4 3,1EER 2,42 2,57 2,64 2,41 2,53 2,65 2,79 2,64ESEER 2,96 3,19 3,16 3,01 3,01 3,21 3,41 3,17Nominal Heating power (2) kW 5,70 6,50 8,10 10 12,4 6,40 8 9,70Total absorbed power (2) kW 2,30 2,40 2,90 3,60 4,50 2,40 2,70 3,20COP 2,48 2,71 2,79 2,78 2,76 2,67 2,96 3,03Absorbed current A 10,6 11,3 13,9 16,1 21,2 4,84 4,94 6,14Nominal water flow (1) m3/h 0,80 0,90 1,10 1,40 1,80 0,90 1,20 1,40Operational weight kg 90 95 110 115 140 95 110 115No. fans N. 1 1 1 1 2 1 1 1Airflow m3/h 2400 3500 3500 4200 6800 3500 3500 4200Compressor type SCROLL SCROLL SCROLL SCROLL SCROLL SCROLL SCROLL SCROLLRefrigerant R410A R410A R410A R410A R410A R410A R410A R410AHydraulic connections inches 3/4” 3/4” 3/4” 3/4” 1” 1/4 3/4” 3/4” 3/4”Sound pressure level (3) dB(A) 54 55 55 55 58 55 55 55Sound power dB(A) 65 66 66 66 69 66 66 66Electrical power supply V-Ph~Hz 230V~50Hz 230V~50Hz 230V~50Hz 230V~50Hz 230V~50Hz 400V-3N~50Hz 400V-3N~50Hz 400V-3N~50HzDIMENSIONL mm 900 900 900 900 900 900 900 900H mm 640 640 940 940 1240 640 940 940P mm 370 370 370 370 370 370 370 370

Page 39: Products Guide V01 - ParagonEfficient project management thanks to Climaveneta as unique project leader. Complete and specialized Organization Climaveneta qualifies itself for the

37

Note:

1 Evaporator water (in/out) 12/7°C, condenser air (in) 35°C, based on Eurovent standard

2 Condenser water (in/out) 40/45°C, evaporator air (in) 7°C (r.h. 87%), based on Eurovent standard

3 Noise level measured at 1 m in open field conditions

BRAN / FF-SLModels 0071 0091 0101 0121HEAT PUMP MODELNominal Cooling capacity (1) kW 18,4 20,8 25,1 31,3Total absorbed power (1) kW 6,5 7,5 7,95 10,35EER 2,83 2,77 3,16 3,02ESEER 3,36 3,26 3,68 3,47Nominal Heating power (2) kW 21,0 23,6 28,8 35,5Total absorbed power (2) kW 6,8 7,6 9,4 11,1COP 3,09 3,11 3,06 3,2Absorbed current A 12,9 13,6 21,3 22,7Nominal water flow (1) m3/h 3,20 3,60 4,30 4,90Useful head (1) kPa 116 90 130 108Operational weight kg 265 270 340 345No. fans N. 2 2 3 3Airflow m3/h 7000 7000 10500 10500Compressor type SCROLL SCROLL SCROLL SCROLLRefrigerant R410A R410A R410A R410AHydraulic connections inches 1” 1/4 1” 1/4 1” 1/4 1” 1/4Sound pressure level (3) dB(A) 62 62 63 63Sound power dB(A) 73 73 74 74Electrical power supply V-Ph~Hz 400V-3N~50Hz 400V-3N~50Hz 400V-3N~50Hz 400V-3N~50HzDIMENSIONL mm 1450 1450 1450 1450H mm 1200 1200 1700 1700P mm 550 550 550 550

Note:

1 Evaporator water (in/out) 12/7°C, condenser air (in) 35°C, based on Eurovent standard

2 Condenser water (in/out) 40/45°C, evaporator air (in) 7°C (r.h. 87%), based on Eurovent standard

3 Noise level measured at 1 m in open field conditions

BRAN / FFT-SLModels 0071 0091 0101 0121HEAT PUMP MODELNominal Cooling capacity (1) kW 18,4 20,8 25,1 31,3Total absorbed power (1) kW 6,5 7,5 7,95 10,35EER 2,83 2,77 3,16 3,02ESEER 3,36 3,26 3,68 3,47Nominal Heating power (2) kW 21,0 23,6 28,8 35,3Total absorbed power (2) kW 6,8 7,6 9,4 11,1COP 3,09 3,11 3,06 3,2Absorbed current A 12,9 13,6 21,3 22,7Nominal water flow (1) m3/h 3,20 3,60 4,30 5,40Operational weight kg 265 280 340 345No. fans N. 2 2 3 3Airflow m3/h 7000 7000 10500 10500Compressor type SCROLL SCROLL SCROLL SCROLLRefrigerant R410A R410A R410A R410AHydraulic connections inches 1” 1/4 1” 1/4 1” 1/4 1” 1/4Sound pressure level (3) dB(A) 62 62 63 63Sound power dB(A) 73 73 74 74Electrical power supply V-Ph~Hz 400V-3N~50Hz 400V-3N~50Hz 400V-3N~50Hz 400V-3N~50HzDIMENSIONL mm 1450 1450 1450 1450H mm 1200 1200 1700 1700P mm 550 550 550 550

Dimension

P

L

H

PL

HH

P

A

Page 40: Products Guide V01 - ParagonEfficient project management thanks to Climaveneta as unique project leader. Complete and specialized Organization Climaveneta qualifies itself for the

38

Main accessoriesRemote control kit

Kit for connecting the KMC keyboard

KMC keyboard for modular system

Coil protection grids

Removable metal mesh water filter kit

Rubber anti-vibration mounting kit

Features Structure and base in hot-dip galvanised steel with epoxy powder paint finish.High-efficiency plate exchangers in AISI 316 stainless steel with low pressure drops, fitted with heating element for frost protection.

External access to control with anti-tamper device.

Finned coils made with copper pipes and aluminium fins with large exchange surface area, tested for leaks with dried air at 30 bar.

User interface with display.

Electronic expansion valve

Available water pipe fittings in case of installation under appliance

Differential pressure switch.

Air vent valve.

The hydronic circuit on the FF models includes:

Multistage centrifugal pump

Expansion tank.

Safety valve.

Pressure gauge.

Drain valve.

VersionsFF base version, with built-in hydronic kit

FFT base version without hydronic kit

CommandsKeyboard Master ControlMICS features an innovative design that optimises the possibilities of connecting up several units, reducing the necessary access space to a minimum and thereby the overall size of the units.

Increasingly better capacity controlThe possibility of controlling up to six units as a single product means that MICS can increase the number of available control steps, thereby ensuring practically perfect adaptation to the real heat load trend.

Modular designKMC is the central control of the cascade modules. Its main function is to supervise operation of all the modules, making them operate synergically. As a user interface it has a graphic display and a keypad for navigating in the pull-down menus.

Full Floating technologyThe full floating technology with automatic control of the airflow rate, water flow rate and water temperature gains a new function: Flex Energy, used to manage the capacity control steps in linear or alternating sequence in installations with several modules.

Hydronic - residential

MICS-N 0072÷0182

Modular reversible unit, air source for outdoor installation

17,3 - 47,9 kWUnit DescriptionMICS-N is the Climaveneta range of reversible air-cooled heat pumps. They are outdoor units with axial fans, hermetic Scroll compressors and Full Floating technology. The latter is an intelligent electronic unit providing the perfect answer to residential market requirements: compactness, ease of installation and quietness.

Page 41: Products Guide V01 - ParagonEfficient project management thanks to Climaveneta as unique project leader. Complete and specialized Organization Climaveneta qualifies itself for the

39

Note:

1 Evaporator water (in/out) 12/7°C, condenser air (in) 35°C, based on Eurovent standard

2 Condenser water (in/out) 40/45°C, evaporator air (in) 7°C (r.h. 87%), based on Eurovent standard

3 Noise level measured at 1 m in open field conditions

MICS-N / FFModels 0072 0092 0122 0152 0182HEAT PUMP MODELNominal Cooling capacity (1) kW 17,3 21,8 30,3 37,4 42,5Total absorbed power (1) kW 6,50 9,30 10,7 13,4 15,5EER 2,66 2,34 2,83 2,79 2,74ESEER 3,86 3,75 3,78 3,92 3,96Nominal water flow m3/h 3 3,80 5,20 6,40 7,30Nominal Heating power (2) kW 20,2 26,1 33,9 42,6 47,9Total absorbed power (2) kW 6,50 8,60 11,2 14 15,4COP 3,11 3,02 3,03 3,04 3,11Absorbed current A 14 17,7 23,9 29,3 31,3Nominal water flow m3/h 3,50 4,50 5,90 7,40 8,30Hydraulic connections inches 1”1/4 1”1/4 1”1/4 1”1/4 1”1/4Operational weight kg 310 330 410 450 480No. fans N. 1 1 2 2 2Airflow m3/h 9000 9000 18000 18000 18000Compressor type SCROLL SCROLL SCROLL SCROLL SCROLLRefrigerant R410A R410A R410A R410A R410ASound pressure level (3) dB(A) 68 68 71 71 71Sound power dB(A) 80 80 83 83 83Electrical power supply V-Ph~Hz 400V-3N~50Hz 400V-3N~50Hz 400V-3N~50Hz 400V-3N~50Hz 400V-3N~50HzDIMENSIONL mm 1040 1040 1630 1630 1630H mm 1630 1630 1630 1630 1630P mm 790 790 790 790 790

COOLINGHEATING

r HFCR-410A

SCROLLAXIALPLATES

Note:

1 Evaporator water (in/out) 12/7°C, condenser air (in) 35°C, based on Eurovent standard

2 Condenser water (in/out) 40/45°C, evaporator air (in) 7°C (r.h. 87%), based on Eurovent standard

3 Noise level measured at 1 m in open field conditions

MICS-N / FFTModels 0072 0092 0122 0152 0182HEAT PUMP MODELNominal Cooling capacity (1) kW 17,3 21,8 30,3 37,4 42,5Total absorbed power (1) kW 6,50 9,30 10,7 13,4 15,5EER 2,66 2,34 2,83 2,79 2,74ESEER 3,86 3,75 3,78 3,92 3,96Nominal water flow m3/h 3 3,80 5,20 6,40 7,30Nominal Heating power (2) kW 20,2 26,1 33,9 42,6 47,9Total absorbed power (2) kW 6,50 8,60 11,2 14 15,4COP 3,11 3,02 3,03 3,04 3,11Absorbed current A 14 17,7 23,9 29,3 31,3Nominal water flow m3/h 3,50 4,50 5,90 7,40 8,30Hydraulic connections inches 1”1/4 1”1/4 1”1/4 1”1/4 1”1/4Operational weight kg 310 330 410 450 480No. fans N. 1 1 2 2 2Airflow m3/h 9000 9000 18000 18000 18000Compressor type SCROLL SCROLL SCROLL SCROLL SCROLLRefrigerant R410A R410A R410A R410A R410ASound pressure level (3) dB(A) 68 68 71 71 71Sound power dB(A) 80 80 83 83 83Electrical power supply V-Ph~Hz 400V-3N~50Hz 400V-3N~50Hz 400V-3N~50Hz 400V-3N~50Hz 400V-3N~50HzDIMENSIONL mm 1040 1040 1630 1630 1630H mm 1630 1630 1630 1630 1630P mm 790 790 790 790 790

Dimension

LP

H

Page 42: Products Guide V01 - ParagonEfficient project management thanks to Climaveneta as unique project leader. Complete and specialized Organization Climaveneta qualifies itself for the

40

Main accessoriesHSW5 remote keyboard

External buffer tank and hydronic connecting kit

External main switch kit

Additional circulating pump kit for models 0041÷0061

Rubber anti-vibration mounting kit

Removable metal mesh water filter kit

FeaturesCondensate collecting tray for all models

Coil protection grid for all models.

Structure and base in hot-dip galvanised steel with epoxy powder paint finish.High-efficiency plate exchangers in AISI 316 stainless steel with low pressure drops, fitted with heating element for frost protection.

External access to control with anti-tamper device.

Finned coils made with copper pipes and aluminium fins with large exchange surface area, tested for leaks with dried air at 30 bar.

User interface with display.

The circuit includes:

Air vent valve.

Water circulator.

Differential pressure switch.

Expansion tank.

Safety valve.

Pressure gauge.

Manual filling assembly.

Drain valve.

CommandsFull Floating featuresThe new generation electronic controller allows to manage the chiller by using the Full Floating technology, designed by Climaveneta for improving the system´s efficiency for the fans (Floating Fans), for the circulating pump (Floating Flow) and finally for the working temperature (Floating Setpoint). This also allows to achieve all the following benefits: improvement of efficiency in both standard and extreme conditions, much lower operating noise in part load conditions, lower installation time, lower time for system set-up, broader operating limits, faster transient after defrosts.

Hydronic - residential

BRN 0011÷0061

Reversible unit, air source for indoor installation

4,6 - 16,8 kWUnit DescriptionBRN is the Climaveneta range air-cooled heat pumps with gas R410A. They are fitted with hermetic Scroll compressors and Full Floating technology. The latter is an intelligent electronic unit providing the perfect answer to residential market requirements: compactness, ease of installation and quietness.

VersionsFF base version, with built-in hydronic kit

FFT base version without hydronic kit

Page 43: Products Guide V01 - ParagonEfficient project management thanks to Climaveneta as unique project leader. Complete and specialized Organization Climaveneta qualifies itself for the

41

Note:

1 Evaporator water (in/out) 12/7°C, condenser air (in) 35°C, based on Eurovent standard

2 Condenser water (in/out) 40/45°C, evaporator air (in) 7°C (r.h. 87%), based on Eurovent standard

3 Noise level measured at 1 m in open field conditions

BRN / FFModels 0011 0021 0025 0031 0041 0021 0025 0031 0041 0051 0061HEAT PUMP MODELNominal Cooling capacity (1) kW 4,6 5,4 6,6 8,2 10,4 5,3 6,7 8,2 10,8 12,6 14,6Total absorbed power (1) kW 2,5 2,6 3,1 4,0 5,2 2,6 3,0 3,7 5,3 5,8 6,4EER 1,84 2,08 2,13 2,05 2,04 2,23 2,22 2 2,04 2,17 2,28ESEER 2,11 2,37 2,53 2,48 2,44 2,62 2,58 2,27 2,36 2,40 2,62Nominal Heating power (2) kW 5,7 6,5 8,1 10,0 12,4 6,4 8,0 9,7 12,8 14,4 16,8Total absorbed power (2) kW 2,8 2,9 3,5 4,2 5,7 2,9 3,3 3,8 5,9 6,1 6,5COP 2,04 2,24 2,31 2,38 2,21 2,42 2,55 2,17 2,17 2,36 2,58Absorbed current A 13,3 14 16,6 18,8 26,6 7,50 7,60 8,80 14,6 14,8 15,3Nominal water flow m3/h 1 1,40 1,70 1,10 1,70 1,10 2,20 1,40 2,20 2,50 2,90Useful head kPa 49 46 42 41 43 46 42 41 43 35 32Operational weight kg 110 125 135 115 135 115 180 125 180 200 210No. fans N. 1 1 1 1 2 1 1 1 2 2 2Airflow m3/h 2200 2700 2400 3100 2x3100 2700 2400 3100 2x3100 2x3000 2x3200Compressor type SCROLL SCROLL SCROLL SCROLL SCROLL SCROLL SCROLL SCROLL SCROLL SCROLL SCROLLRefrigerant R410A R410A R410A R410A R410A R410A R410A R410A R410A R410A R410AHydraulic connections inches 3/4” 3/4” 3/4” 3/4” 1”1/4 3/4” 3/4” 3/4” 1”1/4 1”1/4 1”1/4Sound pressure level (3) dB(A) 55 55 55 55 60 55 55 55 60 60 60Sound power dB(A) 68 68 68 68 68 68 68 71 71 71 71Electrical power supply V-Ph~Hz 230V~50Hz 400V-3N~50HzDIMENSIONL mm 900 900 900 900 900 900 900 900 900 900 900H mm 640 640 940 940 1240 640 940 940 1240 1240 1390P mm 580 580 580 580 580 580 580 580 580 580 630

COOLINGHEATING

r HFCR-410A

SCROLLCENTRIFUGALPLATES

Dimension

P

L

H

Note:

1 Evaporator water (in/out) 12/7°C, condenser air (in) 35°C, based on Eurovent standard

2 Noise level measured at 1 m in open field conditions

BRN / FFTModels 0011 0021 0025 0031 0041 0021 0025 0031 0041 0051 0061HEAT PUMP MODELNominal Cooling capacity (1) kW 4,6 5,4 6,6 8,2 10,4 5,3 6,7 8,2 10,8 12,6 14,6Total absorbed power (1) kW 5,7 6,5 8,1 10 12,4 6,4 8 9,7 12,8 14,4 16,8EER 1,84 2,08 2,13 2,05 2,04 2,23 2,22 2 2,04 2,17 2,28ESEER 2,11 2,37 2,53 2,48 2,44 2,62 2,58 2,27 2,36 2,4 2,62Nominal Heating power kW 5,7 6,5 8,1 10 12,4 6,4 8 9,7 12,8 14,4 16,8Total absorbed power kW 2,8 2,9 3,5 4,2 5,7 2,9 3,3 3,8 5,9 6,1 6,5COP 2,04 2,24 2,31 2,38 2,21 2,42 2,55 2,17 2,17 2,36 2,58Absorbed current ANominal water flow m3/h 1 1,4 1,7 1,1 1,7 1,1 2,2 1,4 2,2 2,5 2,9Operational weight kg 110 125 135 115 135 115 180 125 180 200 210No. fans N. 1 1 1 1 2 1 1 1 2 2 2Airflow m3/h 2200 2700 2400 3100 2x3100 2700 2400 3100 2x3100 2x3000 2x3200Compressor type SCROLL SCROLL SCROLL SCROLL SCROLL SCROLL SCROLL SCROLL SCROLL SCROLL SCROLLRefrigerant R410A R410A R410A R410A R410A R410A R410A R410A R410A R410A R410AHydraulic connections inches 3/4” 3/4” 3/4” 3/4” 1” 1/4 3/4” 3/4” 3/4” 1” 1/4 1” 1/4 1” 1/4Sound pressure level (2) dB(A) 55 55 55 55 60 55 55 55 60 60 60Sound power dB(A) 68 68 68 68 68 68 68 71 71 71 71Electrical power supply V-Ph~Hz 230V~50Hz 400V-3N~50HzDIMENSIONL mm 900 900 900 900 900 900 900 900 900 900 900H mm 640 640 940 940 1240 640 940 940 1240 1240 1390P mm 580 580 580 580 580 580 580 580 580 580 630

Page 44: Products Guide V01 - ParagonEfficient project management thanks to Climaveneta as unique project leader. Complete and specialized Organization Climaveneta qualifies itself for the

42

Main accessoriesRubber anti-vibration mounting kit

Removable metal mesh water filter kit

Coil protection grids

Remote control kit

Features Structure and base in hot-dip galvanised steel with epoxy powder paint finish.High-efficiency plate exchangers in AISI 316 stainless steel with low pressure drops, fitted with heating element for frost protection.

External access to control with anti-tamper device.

Finned coils made with copper pipes and aluminium fins with large exchange surface area, tested for leaks with dried air at 30 bar.

User interface with display.

Electronic expansion valve

Available water pipe fittings in case of installation under appliance

The circuit includes:

Multistage centrifugal pump

Air vent valve.

Differential pressure switch.

Expansion tank.

Safety valve.

Pressure gauge.

Drain valve.

VersionsFF base version, with built-in hydronic kit

CommandsFull Floating technologyThe new generation electronic controller allows to manage the chiller by using the Full Floating technology, designed by Climaveneta for improving the system´s efficiency for the fans (Floating Fans), for the circulating pump (Floating Flow) and finally for the working temperature (Floating Setpoint). This also allows to achieve all the following benefits: improvement of efficiency in both standard and extreme conditions, much lower operating noise in part load conditions, lower installation time, lower time for system set-up, broader operating limits, faster transient after defrosts.

Hydronic - residential

MICS-CN 0072÷0122

Reversible unit, air source for indoor installation

17,3 - 33,9 kWUnit DescriptionMICS-CN is the Climaveneta range air-cooled heat pumps with gas R410A. These are indoor units that, thanks to the ducted centrifugal fans, may also be installed outdoors. They are fitted with hermetic Scroll compressors and Full Floating technology. The latter is an intelligent electronic unit providing the perfect answer to residential market requirements: compactness, ease of installation and quietness.

Page 45: Products Guide V01 - ParagonEfficient project management thanks to Climaveneta as unique project leader. Complete and specialized Organization Climaveneta qualifies itself for the

43

Note:

1 Evaporator water (in/out) 12/7°C, condenser air (in) 35°C, based on Eurovent standard

2 Condenser water (in/out) 40/45°C, evaporator air (in) 7°C (r.h. 87%), based on Eurovent standard

3 Noise level measured at 1 m in open field conditions

MICS-CN / FFModels 0072 0092 0122HEAT PUMP MODELNominal Cooling capacity (1) kW 17,3 21,8 30,3Total absorbed power (1) kW 6,50 9,32 10,7EER 2,66 2,34 2,83ESEER 3,86 3,75 3,78Nominal water flow m3/h 3 3,80 5,20Nominal Heating power (2) kW 20,2 26 33,9Total absorbed power (2) kW 6,50 8,61 11,2COP 3,11 3,02 3,03Absorbed current A 16,1 19,8 27,3Nominal water flow m3/h 3,50 4,50 5,90Hydraulic connections inches 1”1/4 1”1/4 1”1/4Operational weight kg 310 330 410No. fans N. 1 1 2Airflow m3/h 9000 9000 18000Compressor type SCROLL SCROLL SCROLLRefrigerant R410A R410A R410ASound pressure level (3) dB(A) 74 74 77Sound power dB(A) 86 86 89Electrical power supply V-Ph~Hz 400V-3N~50Hz 400V-3N~50Hz 400V-3N~50HzDIMENSIONL mm 1040 1040 1630H mm 2000 2000 2000P mm 790 790 790

COOLINGHEATING

r HFCR-410A

SCROLLCENTRIFUGALPLATES

Dimension

L P

H

Page 46: Products Guide V01 - ParagonEfficient project management thanks to Climaveneta as unique project leader. Complete and specialized Organization Climaveneta qualifies itself for the

44

Main accessoriesRemovable metal mesh water filter kit

External temperature sensor (mandatory with HSW12 remote keyboard)

HSW12 remote keyboard

Features Structure and base in hot-dip galvanised steel with epoxy powder paint finish.High-efficiency plate exchangers in AISI 316 stainless steel with low pressure drops, fitted with heating element for frost protection.

External access to control with anti-tamper device.

User interface with display.

The safety of the unit is guaranteed by a door lock isolator on the electrical power switchboard and by active protection devices on the main components.

The circuit includes:

Circulating pump (plant side, FF versions only).

Air vent valve (plant side).

Modulating valve to reduce water consumptions (source side, FF versions only).

Expansion vessel (plant side).

Safety valve (plant side).

Differential pressure switch on both plant and source circuits.

Drain valve on both plant and source circuits.

VersionsWWr MTD base version

CommandsFloating SetOnce ever y 3 minutes an algorithm automatically optimises the water set point in relation to the compressor operating time and the temperatures of the water in the system. he water storage tank is no longer indispensable because it is compensated by the Floating Set function, with resulting reduction in: size; weight; installation times; system setting-up times.

Floating FlowThe controller manages the modulation of the active components (pump and electronic flow valve) through pressure transducers and temperature sensors. The performance of the unit may thus be optimised for different operating conditions, such as traditional fan coil system and panel heating system, ensuring: broader operating limits; easier start-up of installations with both high and low water temperatures; faster system setup.

Hydronic - residential

WWr MTD 011m÷121t

Reversible unit, water source

5,2 - 41,7 kWUnit DescriptionWWr MTD is the Climaveneta range of water-cooled heat pumps provided with R410A refrigerant. These are indoor units with hermetic Scroll compressors and Full Floating technology. The latter is an intelligent electronic unit providing the perfect answer to residential market requirements: compactness, ease of installation and quietness.

Page 47: Products Guide V01 - ParagonEfficient project management thanks to Climaveneta as unique project leader. Complete and specialized Organization Climaveneta qualifies itself for the

45

Note:

1 Evaporator water (in/out) = 12/7°C, condenser water (in/out) = 30/35°C, based on Eurovent Standard

2 Evaporator water (in/out), 10/5°C, condenser water (in/out) 40/45°C, based on Eurovent standard

3 Sound pressure measured at 1 m in open field conditions

Models 021t 025t 031t 041t 051t 061t 071t 091t 101t 121tHEAT PUMP MODELNominal Cooling capacity (1) kW 5,60 7,30 8,90 11,8 13,2 15,7 19,8 22,9 26 33,4Total power input (1) kW 1,60 1,90 2,40 3,20 3,80 4 5,10 5,80 6,80 8,40EER 3,50 3,84 3,71 3,69 3,47 3,93 3,88 3,95 3,82 3,98ESEER 3,81 4,39 4,17 4,08 4,02 4,51 4,40 4,61 4,33 4,37Water flow rate plant side (1) m3/h 1 1,30 1,50 2 2,30 2,70 3,40 3,90 4,50 5,70Heating capacity (2) 7,40 9,20 11,4 15,3 17,1 20 24,8 28,8 33 41,7Total absorbed power (2) kW 1,90 2,20 2,70 3,70 4,20 4,60 5,80 6,40 7,60 9,50COP 3,89 4,18 4,22 4,14 4,07 4,35 4,28 4,50 4,34 4,39Water flow rate plant side (2) 1,30 1,60 2 2,60 2,90 3,40 4,30 5 5,70 7,20Absorbed current A 4,60 5 6,10 7,40 8,10 8,80 12,2 13,4 16,1 19,2Operational weight kg 148 150 152 160 170 175 220 230 235 250Compressor type SCROLL SCROLL SCROLL SCROLL SCROLL SCROLL SCROLL SCROLL SCROLL SCROLLRefrigerant R410A R410A R410A R410A R410A R410A R410A R410A R410A R410AHydraulic connections inches G 3/4” G 3/4” G 3/4” G 1”1/4 G 1”1/4 G 1”1/4 G 1”1/4 G 1”1/4 G 1”1/4 G 1”1/4Sound pressure level (3) dB(A) 41 42 42 47 47 48 55 55 59 59Sound power dB(A) 52 53 53 58 58 59 66 66 70 70Electrical power supply V-Ph~Hz 400V-3N~50Hz 400V-3N~50Hz 400V-3N~50Hz 400V-3N~50Hz 400V-3N~50Hz 400V-3N~50Hz 400V-3N~50Hz 400V-3N~50Hz 400V-3N~50Hz 400V-3N~50HzDIMENSIONL mm 560 560 560 560 560 560 680 680 680 680H mm 980 980 980 980 980 980 1150 1150 1150 1150P mm 575 575 575 575 575 575 780 780 780 780

WWr MTD Models 011m 021m 025m 031m 041mHEAT PUMP MODELNominal Cooling capacity (1) kW 5,20 5,60 7,20 8,80 11,3Total power input (1) kW 1,50 1,70 2 2,60 3,20EER 3,47 3,29 3,60 3,38 3,53ESEER 4,03 3,73 4,26 3,95 3,90Water flow rate plant side (1) m3/h 0,90 1 1,20 1,50 1,90Heating capacity (2) 6,80 7,50 9,20 11,6 14,6Total absorbed power (2) kW 1,70 1,90 2,30 3 3,60COP 4 3,95 4 3,87 4,06Water flow rate plant side (2) 1,20 1,30 1,60 2 2,50Absorbed current A 7,50 8 8,90 12,3 15,6Operational weight kg 148 148 150 152 160Compressor type SCROLL SCROLL SCROLL SCROLL SCROLLRefrigerant R410A R410A R410A R410A R410AHydraulic connections inches G 3/4” G 3/4” G 3/4” G 3/4” G 1”1/4Sound pressure level (3) dB(A) 41 41 42 42 47Sound power dB(A) 52 52 53 53 58Electrical power supply V-Ph~Hz 230V~50Hz 230V~50Hz 230V~50Hz 230V~50Hz 230V~50HzDIMENSIONL mm 560 560 560 560 560H mm 980 980 980 980 980P mm 575 575 575 575 575

COOLINGHEATING

r HFCR-410A

SCROLLPLATES

Dimension

L P

H

Page 48: Products Guide V01 - ParagonEfficient project management thanks to Climaveneta as unique project leader. Complete and specialized Organization Climaveneta qualifies itself for the
Page 49: Products Guide V01 - ParagonEfficient project management thanks to Climaveneta as unique project leader. Complete and specialized Organization Climaveneta qualifies itself for the
Page 50: Products Guide V01 - ParagonEfficient project management thanks to Climaveneta as unique project leader. Complete and specialized Organization Climaveneta qualifies itself for the

48

PRANA

i-NRG 0061m÷0061t

Versioni

i-NRG Reversible heat pump with inverter compressor, total heat recovery, air source for indoor/outdoor installation

Features

Structure and base in hot galvanised epoxy powder coatedsteel.Stainless steel (AISI 316) with high efficiency and lowpressure drop plate to plate exchanger (at the domestic hotwater side). It is positioned next after the compressor, itensures the domestic hot water production. That can workeither in full recovery or in part, with the constantoptimization of efficiency through logic advanced adjustingcontrollerExchangers plant side plate of stainless steel AISI 316 withhigh efficiency and low pressure drop meets the supply ofboth hot or cold water for the facility, regardless of thedomestic hot waterDC inverter scroll compressor with self-adaptive capacityadjustment.Electronic expansion valveFinned coils made with copper pipes and aluminium finswith large exchange surface area (100% fully quality tested)Axial electric fan in continuous current housed inaerodynamic conveyor profile with safety grill.Low external air temperature device: continuous fan speedregulation with pressure switchThe water circuit comes complete with:

• Variable flow circulating pump in continuous current, plant side.

• Variable flow circulating pump in continuous current, hot water side.

• Expansion tank 10 lt.• Safety valve 3 bar.• Differential pressure swich plant side.• Pressure gauge.• Manual filling assembly.

Main accessories• Room terminal with temperature and humidity probe• Expansion module for plant circuits additional• Expansion module for solar thermal collector• Buffer tank 35,100,200 liters• Hot water cylinder 300,500 liters• 300 litres thermal store for domestic hot water, for kit

DOMH2O• 300, 500, 1000 litres thermal store for domestic hot

water with solar heat exchanger, for kit DOMH2O• DOMH2O15 e DOMH2O24 kit for domestic hot water

with external heat exchanger plate-to-plateand pump

• Removable metal mesh water filter kit• Kit acoustic insulationg casing kit (mandatory for

outdoor installation) • KIt rectangular air ducts and grills for indoor installation

Unit descriptionThe new i-NRG heat pump provides exactly the energy required by the system,perfectly following the real load of the building, thanks to the modulation of the DCinverter fan. One single unit for the highest efficiency, sustainability and huge savings,thanks to the advantages of DC frequency driven fans and circulating pumps (inverter)for both plant and domestic hot water circuits.i-NRG is the new generation heat pump for all year round operation in any operatingmode: single cycle (air conditioning, heating, domestic hot water) as well as combinedcycle (domestic hot water together with heating or cooling). Domestic hot waterproduction is guaranteed by the dedicated exchanger for heat recovery: total, for freedomestic hot water production, or partial. Domestic hot water is stored in a properlydimensioned storage tank.

The unit can be installed indoor or outdoor, thus ensuring complete flexibility.

CommandsElectronic control provides great application flexibility. The remote keyboard kit wired indoor and outdoortemperature sensors allow dynamic control of delivery temperature water, optimizing comfort in the room andincreasing the energy efficienty. The electronic board allows you to manage:- a zone of direct heating for radiator, floor heating or fan coil- zone with mix valve for floor heating- outdoor temperature sensor for water plant side modular set point compensation- electrical heating element for possible integration and anti-legionellosis cycle for cylinder- boiler in substitution or in additional- integration by solar panels with extension module (accessorie)- several solutions through appropriate configurations of the controller and use of dedicated extension modules

(accessories)

Reversible heat pump with invertercompressor, total heat recovery, air sourcefor indoor/outdoor installation 16,3 kW

Page 51: Products Guide V01 - ParagonEfficient project management thanks to Climaveneta as unique project leader. Complete and specialized Organization Climaveneta qualifies itself for the

H

L (9)

P

L (8)

NOTE(1) Water in-out 30/35°C (plant side), outdoor air temperature 7°C b.s./ 6°C b.u.(2) Total input is obtained from compressor input and fan input.(3) Water in-out 23/18°C (plant side), outdoor air temperature 35°C b.s.(4) Water in-out 23/18°C (plant side), water in-out 45/50°C (total recovery side)(5) i-Ci= Circolatore inverter corrente continua(6) Sound power level according to ISO 9614 and Eurovent 8/1(7) Average sound pressure level above one reflecting surface (Q=2) at 1 meter from the outside dimensions of the unit.(8) Indoor installation(9) Outdoor installation

0061m 0061t

16,3 16,3

4,0 4,0

3,91 3,94

19,6 19,7

5,40 5,40

3,62 3,66

17,9 18

4,9 4,9

22,6 22,6

SCROLL INVERTER DC SCROLL INVERTER DC

1 1

R410A R410A

1 1

i-Ci i-Ci

i-Ci i-Ci

230-1~50 400-3N~50

68 68

52 52

750 750

1535 1535

1600 1600

1050 1050

260 260

Models

Nominal heating power (1) kW

Total absorbed power (2) kW

COP EN 14511

Cooling capacity (3) kW

Total absorbed power (2) kW

EER EN 14511

Total absorbed power (4) kW

Total absorbed power kW

Recovery heating capacity kW

Compressor type

N. Compressors N.

Refrigerant

N. fans N.

Plant side pump type (5)

Recovery side pump type (5)

Electrical power supply V-Ph~Hz

Sound power (6) dB(A)

Sound pressure (7) dB(A)

DIMENSION

L (8) mm

L (9) mm

H mm

P mm

Operational weight kg

i-NRG

49

Page 52: Products Guide V01 - ParagonEfficient project management thanks to Climaveneta as unique project leader. Complete and specialized Organization Climaveneta qualifies itself for the

50

PRANA

AWR DHW 0021m÷0101ts

Versioni

AWR DHW Air source reversible heat pump with domestic hot water supply with total heat recovery

AWR DHW - SL Air source reversible heat pump with domestic hot water supply with total heat recovery

Features

Structure and base in hot galvanised epoxy powder coatedsteel.Stainless steel (AISI 316) with high efficiency and lowpressure drop plate to plate exchanger (at the domestic hotwater side). It is positioned next after the compressor, itensures the domestic hot water production. That can workeither in full recovery or in part, with the constantoptimization of efficiency through logic advanced adjustingcontroller.Exchangers plant side plate of stainless steel AISI 316 withhigh efficiency and low pressure drop meets the supply ofboth hot or cold water for the facility, regardless of thedomestic hot waterHermetic scroll type compressors, equipped with thecrankcase heater and thermal protectionFinned coils made with copper pipes and aluminium finswith large exchange surface area (100% fully quality tested)Axial electric fans, external rotor, electric motor with a 6-polefitted with thermal protection, housed in aerodynamicconveyor profile with safety grillLow external air temperature device: continuous fan speedregulation with pressure switchCoil protection grilleSoft starter for 230V units /ms and 400V units /tsThe water circuit comes complete with:

• Variable flow circulator for 0021÷0025 models and multistage centrifugal variable flow pump for models 0041÷0101, plant side

• Domestic hot water side water pump• Expansion tank• Safety valve• Manual filling assembly• Pressure gauge• Air vent valve

Comando accessibile dallesterno con dispositivoantimanomissione

Main accessories• Buffer tank 35,100,200 liters• Hot water cylinder 300,500 liters• 300 litres thermal store for domestic hot water, for kit

DOMH2O• 300,500,1000 litres thermal store for domestic hot water

with solar heat exchanger, for kit DOMH2O• DOMH2O15 e DOMH2O24 kit for domestic hot water

with external heat exchanger plate-to-plate and pump• Remote keyboard• Rubber anti-vibration mounting kit• Removable metal mesh water filter kit• Condensate collecting tray for models 0065÷0101

Unit descriptionPRANA DHW is the heat pump new generation able to operate throughout the year in anyoperating mode: either a single cycle (cooling, heating, hot water) and combined cycle (hotwater along with air conditioning or heating). Energy efficiency is highest during the summercycle, when, thanks to the full recovery of the heat, the production of hot water is free.During the combined use, the DHW exchanger uses the temperature of the dischargegases to gets inside the accumulation sanitary water as high as 65° C. The advancedelectronic regulation developed by Climaveneta ensures the highest operational flexibility, fastworking condition a significant increase in the overall COP, which go hand in hand withelectricity and space reduction. Advantages, combined with the possibility of completelyeliminating the traditional boiler, making heat pumps PRANA DHW the ideal solution for

energy saving applications in residential, hotel and small sector.

CommandsAWR-DHW heats water stored in the tank as energy storage. It also comes with a state-of-the-art electronic unit,which independently controls the modes of operation. The appliance can operate throughout the year in anymode, both with single cycle (cooling, heating, hot water) and with combined cycle (hot water together withcooling or hot water together heating).During the summer cycle there is maximum energy saving through total heatrecovery. This energy is completely free of charge with regard to the production of hot water.

Reversible heat pump, total heatrecovery, air source for outdoorinstallation 7,7 ÷ 33,5 kW

Page 53: Products Guide V01 - ParagonEfficient project management thanks to Climaveneta as unique project leader. Complete and specialized Organization Climaveneta qualifies itself for the

H

L

P

51

NOTE(1) Water in-out 30/35°C (plant side), outdoor air temperature

7°C b.s./ 6°C b.u.(2) Total input is obtained from compressor input and fan input(3) Water in-out 23/18°C (plant side), outdoor air temperature 35°C b.s.(4) Water in-out 23/18°C (plant side), water in-out 45/50°C

(total recovery side)(5) Water in-out 40/45°C (plant side), outdoor air temperature

7°C b.s./ 6°C b.u.

(6) Water in-out 12/7°C (plant side), outdoor air temperature 35°C b.s.(7) Ci=Circolatore; Ce=Centrifuga(8) Sound power level according to ISO 9614 and Eurovent 8/1(9) Average sound pressure level above one reflecting surface (Q=2)

at 1 meter from the outside dimensions of the unit.

* secondo Eurovent

Models 0021m 0025m 0041m 0021ms 0025ms 0041ms 0025t 0041t 0065t 0101t 0025ts 0041ts 0065ts 0101ts

Nominal heating power (1) kW 7,70 9,10 13 7,70 9,10 13 9,10 13 21,3 33,5 9,10 13 21,3 33,5

Total absorbed power (2) kW 2,30 2,70 3,70 2,30 2,70 3,70 2,70 3,70 5,60 8,50 2,70 3,70 5,60 8,50

COP * 3,35 3,37 3,51 3,35 3,37 3,51 3,37 3,51 3,80 3,94 3,37 3,51 3,80 3,94

Cooling capacity (3) kW 7,60 8,90 12,7 7,60 8,90 12,7 8,90 12,7 21,1 33 8,90 12,7 21,1 33

Total absorbed power (2) kW 2,40 2,70 3,80 2,40 2,70 3,80 2,70 3,80 5,80 9,40 2,70 3,80 5,80 9,40

EER * 3,17 3,30 3,34 3,17 3,30 3,34 3,30 3,34 3,64 3,51 3,30 3,34 3,64 3,51

Total absorbed power (4) kW 7,40 8,50 11,8 7,40 8,50 11,8 8,40 11,9 18,2 33,1 8,40 11,9 18,2 33,1

Total absorbed power kW 2,30 2,70 4 2,30 2,70 4 2,60 4 6,10 9,40 2,60 4 6,10 9,40

Recovery heating capacity kW 9,60 11,0 15,5 9,60 11,0 15,5 10,9 15,6 23,9 42,0 10,9 15,6 23,9 42,0

Heating capacity (5) kW 7,60 9 12,8 7,60 9 12,8 9,10 12,9 20,9 32,6 9,10 12,9 20,9 32,6

Total absorbed power (2) kW 2,90 3,40 4,60 2,90 3,40 4,60 3,40 4,60 7 10,3 3,40 4,60 7 10,3

COP * 2,66 2,68 2,78 2,66 2,68 2,78 2,68 2,81 2,99 3,17 2,68 2,81 2,99 3,17

Cooling capacity (6) kW 5,40 6,30 9,10 6,40 7,30 11,2 6,30 9,00 15,1 23,7 7,30 11,2 17 27,7

Total absorbed power (2) kW 2,40 2,70 3,70 2,40 2,70 3,80 2,70 3,60 5,40 9,00 2,70 3,80 5,90 9,50

EER * 2,25 2,33 2,46 2,25 2,33 2,46 2,33 2,50 2,80 2,63 2,33 2,50 2,80 2,63

Compressor type SCROLL

N. Compressors N. 1

Refrigerant R407C

N. fans N. 2 2 2 2 2 2 2 2 1 2 2 2 1 2

Plant side pump type (7) Ci Ci Ce Ci Ci Ce Ci Ce Ce Ce Ci Ce Ce Ce

Recovery side pump type (7) Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci

Electrical power supply V-Ph~Hz 230-1~50 230-1~50 230-1~50 230-1~50 230-1~50 230-1~50 400-3N~50 400-3N~50 400-3N~50 400-3N~50 400-3N~50 400-3N~50 400-3N~50 400-3N~50

Corrente di spunto A 61 78 114 29 34 45 40 50 101 127 22 28 56 70

Sound power (8) dB(A) 68 69 70 68 69 70 69 70 76 77 69 70 76 77

Sound pressure (9) dB(A) 53 54 55 53 54 55 54 55 60 61 54 55 60 61

DIMENSION

L mm 1125 1125 1250 1125 1125 1250 1125 1250 1700 1700 1125 1250 1700 1700

H mm 1125 1125 1125 1125 1125 1125 1125 1125 1200 1700 1125 1125 1200 1700

P mm 370 370 420 370 370 420 370 420 650 650 370 420 650 650

Operational weight kg 144 144 168 144 144 168 144 168 295 378 144 168 295 378

Models 0065t 0101t 0065ts 0101ts

Nominal heating power (1) kW 21,3 33,5 21,3 33,5

Total absorbed power (2) kW 5,60 8,50 5,60 8,50

COP * 3,80 3,94 3,80 3,94

Cooling capacity (3) kW 21,1 33 21,1 33

Total absorbed power (2) kW 5,80 9,40 5,80 9,40

EER * 3,64 3,51 3,64 3,51

Total absorbed power (4) kW 18,2 33,1 18,2 33,1

Total absorbed power kW 6,10 9,40 6,10 9,40

Recovery heating capacity kW 23,9 42,0 23,9 42,0

Heating capacity (5) kW 21 32,9 21 32,9

Total absorbed power (2) kW 7,10 10,5 7,10 10,5

COP * 2,97 3,15 2,97 3,15

Cooling capacity (6) kW 15,2 23,9 15,2 23,9

Total absorbed power (2) kW 5,30 8,80 5,30 8,80

EER * 2,87 2,72 2,87 2,72

Compressor type SCROLL SCROLL SCROLL SCROLL

N. Compressors N. 1 1 1 1

Refrigerant R407C R407C R407C R407C

N. fans N. 2 3 2 3

Plant side pump type (7) Ce Ce Ce Ce

Recovery side pump type (7) Ci Ci Ci Ci

Electrical power supply V-Ph~Hz 400-3N~50 400-3N~50 400-3N~50 400-3N~50

Start-up current A 101 127 56 70

Sound power (8) dB(A) 73 74 73 74

Sound pressure (9) dB(A) 57 58 57 58

DIMENSION

L mm 1700 1700 1700 1700

H mm 1200 1700 1200 1700

P mm 650 650 650 650

Operational weight kg 295 378 295 378

AWR DHW

AWR DHW SL

Page 54: Products Guide V01 - ParagonEfficient project management thanks to Climaveneta as unique project leader. Complete and specialized Organization Climaveneta qualifies itself for the

52

PRANA

AWR MTD1 0021ms÷0061t

Versioni

AWR MTD1 Medium temperature air source reversible heat pump for water heating up to 55°C

FeaturesStructure and base in hot galvanised epoxy powder coatedsteel.High efficiency and low pressure drop stainless steel (AISI 316)water exchangers complete with closed-cell insulation withvapour barrier,antifreeze heating element and differencialpressure switchHermetic scroll type compressors, equipped with the crankcaseheater and thermal protectionFinned coils made with copper pipes and aluminium fins withlarge exchange surface area (100% fully quality tested)Axial electric fans, external rotor, electric motor with a 6-polefitted with thermal protection, housed in aerodynamic conveyorprofile with safety grillLow external air temperature device: - continuous fan speedregulation with pressure switchCondensate collecting trayCoil protection grilleSoft starter for 230V/1/50Hz unitsThe water circuit comes complete with:

• Variable flow circulator for all models• Water side differential pressure switch• Expansion tank• Safety valve• Manual filling assembly• Pressure gauge• Air vent valve

Control with foolproof device accessible from the outside

Main accessories• Valvola deviatrice a 3 vie per produzione acqua calda sanitaria• Disgiuntore idraulico da 35, 100, 200 litri• Bollitore acqua calda sanitaria da 300, 500 litri• Termoaccumulo per acqua calda sanitaria da 300 litri, da

abbinare al kit preparatore istantaneo DOMH2O• Termoaccumulo per acqua calda sanitaria da 300, 500 litri con

serpentino solare, da abbinare al kit preparatore istantaneoDOMH2O

• Kit gestione caldaia in sostituzione• Kit preparatore istantaneo acqua calda sanitaria DOMH2O15 e

DOMH2O24• Kit resistenza elettrica da 1, 2, 3 kW• Accumulo esterno e kit di collegamento idraulico• Kit filtro acqua a rete metallica estraibile• Supporti antivibranti in gomma• Tastiera remota HSW11

Unit descriptionHeat pumps AWR-MTD1 are reversible outdoor units with axial fans, hermetic scrollcompressors and Full Floating technology. Full Floating is advanced electronics whichhas been developed by CLIMAVENETA in order to meet the needs of typical residentialsmall size and small/medium tertiary sector, thanks to the accumulation. Anotheradvantage that, together with the Hydraulic module components it make extremelysimple the installation of heat pump: simply by connecting the unit to water plant and

electricity so that it can be put into operation.

CommandsThe new generation electronic controller allows to manage the heat pump by using the Full Floating technology,designed by Climaveneta for improving the system´s efficiency for the fans (Floating Fans), for the circulating pump(Floating Flow) and finally for the working temperature (Floating Setpoint). This also allows to achieve all thefollowing benefits: chiller operation even with larger operating limits, improvement of efficiency in both standardand extreme conditions, much lower operating noise in part load conditions, lower installation time, lower time forsystem set-up, broader operating limits, faster transient after defrosts.The electronic menu allows to manage:- domestic hot water production by external three-way valve (accessory)- a zone of direct heating- outdoor temperature sensor for water plant side modular set point compensation- electrical heating element for possible integration and anti-legionellosis cycle for cylinder- boiler or electric heater management

Reversible heat pump, air source foroutdoor installation6,9 ÷ 17,4 kW

Page 55: Products Guide V01 - ParagonEfficient project management thanks to Climaveneta as unique project leader. Complete and specialized Organization Climaveneta qualifies itself for the

53

NOTE(1) Water in-out 30/35°C (plant side), outdoor air temperature 7°C b.s./ 6°C b.u.(2) Total input is obtained from compressor input and fan input(3) Water in-out 23/18°C (plant side), outdoor air temperature 35°C b.s.(4) Water in-out 40/45°C (plant side), outdoor air temperature 7°C b.s./ 6°C b.u.(5) Water in-out 12/7°C (plant side), outdoor air temperature 35°C b.s.(6) Ci=Circulator; Ce=Centrifugal(7) Sound power level according to ISO 9614 and Eurovent 8/1(8) Average sound pressure level above one reflecting surface (Q=2) at 1 meter from the

outside dimensions of the unit.

* secondo Eurovent

Models 0021ms 0031ms 0041ms 0051ms 0041t 0051t 0061t

Nominal heating power (1) kW 6,90 10,2 12,9 13,4 13 15,2 17,4

Total absorbed power (2) kW 1,70 2,60 3,40 3,20 3,50 3,90 4,10

COP Eurovent * 3,95 3,94 3,82 4,14 3,77 3,88 4,27

Cooling capacity (3) kW 6,80 10,3 12,9 13,9 13,4 15,9 18,4

Total absorbed power (2) kW 2 3,40 4,10 4 4,20 4,60 5,40

EER Eurovent * 3,40 2,98 3,06 3,37 3,20 3,25 3,38

Heating capacity (4) kW 6,80 10,1 12,7 13,1 13 14,6 17

Total absorbed power (2) kW 2,20 3,30 4,20 4 4,40 4,70 5

COP Eurovent * 3,09 3,06 3,02 3,27 2,95 3,11 3,40

Cooling capacity (5) kW 5,10 7,80 9,90 10,5 10,3 11,9 13,9

Total absorbed power (2) kW 2 3,30 3,90 3,80 4 4,50 5

EER Eurovent * 2,55 2,36 2,54 2,76 2,58 2,64 2,78

ESEER 3,15 2,98 3,06 3,37 3,20 3,25 3,38

Compressor type SCROLL

N. Compressors N. 1

Refrigerant R410A

N. fans N. 1 1 2 2 2 2 2

Plant side pump type (6) Ci Ci Ci Ci Ci Ci Ci

Electrical power supply V-Ph~Hz 230-1~50 230-1~50 230-1~50 230-1~50 400-3N~50 400-3N~50 400-3N~50

Start-up current A 27 44 45 45 64 64 74

Sound power (7) dB(A) 66 66 69 69 69 69 69

Sound pressure (8) dB(A) 52 52 54 54 54 54 54

DIMENSION

L mm 900 900 900 900 900 900 900

H mm 640 940 1240 1240 1240 1240 1390

P mm 370 370 370 370 370 370 420

Operational weight kg 95 115 140 160 140 160 170

AWR MTD1

H

LP

H

LP

Page 56: Products Guide V01 - ParagonEfficient project management thanks to Climaveneta as unique project leader. Complete and specialized Organization Climaveneta qualifies itself for the

54

PRANA

AWR MTD XE 0011ms÷0091t

Versioni

AWR MTD XE Medium temperature air source reversible heat pump for water heating up to 55°C andoperating limits down to -15°C external air temperature

AWR MTD XE/H Medium temperature air source reversible heat pump for water heating up to 55°C andoperating limits down to -15°C external air temperature

FeaturesStructure and base in hot galvanised epoxy powder coated steel.High efficiency and low pressure drop stainless steel (AISI 316) waterexchangers complete with closed-cell insulation with vapourbarrier,antifreeze heating element and differencial pressure switchHermetic scroll type compressors, equipped with the crankcaseheater and thermal protectionFinned coils made with copper pipes and aluminium fins with largeexchange surface area (100% fully quality tested)Axial electric fans, external rotor, electric motor with a 6-pole fittedwith thermal protection, housed in aerodynamic conveyor profile withsafety grillLow external air temperature device: continuous fan speed regulationwith pressure switchElectrical resistance modulating antifreeze to the base locatedbetween wing and base exchanger to improve and facilitate the flowof water during defrostingCondensate collecting trayCoil protection grilleSoft starter for 230V/1/50Hz unitsPhase sequence control relayThe water circuit comes complete with:

• Variable flow circulator for all models• Water side differential pressure switch• Expansion tank• Safety valve• Manual filling assembly• Pressure gauge• Air vent valve

Control with foolproof device accessible from the outside

Main accessories• Main accessories• Three-way valve for domestic hot water• Buffer tank 35,100,200 liters• Hot water cylinder 300,500 liters• 300 litres thermal store for domestic hot water, for kit DOMH2O• 300,500 litres thermal store for domestic hot water with solar

heat exchanger, for kit DOMH2O• Kit boiler control• DOMH2O15 e DOMH2O24 kit for domestic hot water with

external heat exchanger plate-to-plate and pump• 1,2,3 kW single-phase electric heater kit• External buffer tank and hydronic connecting kit• Removable metal mesh water filter kit• Rubber anti-vibration mounting kit• HSW11 Remote keyboard

Unit descriptionHeat pumps AWR-MTD-XE reversible units are able to provide heating, cooling anddomestic hot water. Particular attention was paid to the winter, thanks to specialtechnological devices is guaranteed beyond the normal limits of traditional units. PranaAWR-MTD-XE Air can be combined with traditional systems or radiant panels, ensuring ahigh energy efficiency. All units are certified in accordance with the Class A classificationEurovent energy in heating. This makes them particularly suitable for use radiantinstallations. The installation is greatly simplified through the integration of the group andhydraulic technology Full floating simply by connecting the unit to water plant and

electricity so that it can be put into operation.

CommandsThe new generation electronic controller allows to manage the heat pump by using the Full Floating technology,designed by Climaveneta for improving the system´s efficiency for the fans (Floating Fans), for the circulating pump(Floating Flow) and finally for the working temperature (Floating Setpoint). This also allows to achieve all thefollowing benefits: chiller operation even with larger operating limits, improvement of efficiency in both standardand extreme conditions, much lower operating noise in part load conditions, lower installation time, lower time forsystem set-up, broader operating limits, faster transient after defrosts.The electronic menu allows to manage:- domestic hot water production by external three-way valve (accessory)- a zone of direct heating- outdoor temperature sensor for water plant side modular set point compensation- electrical heating element for possible integration and anti-legionellosis cycle for cylinder- boiler or electric heater management

High efficiency reversible heat pump, airsource for outdoor installation6,3 ÷ 17,9 kW

Page 57: Products Guide V01 - ParagonEfficient project management thanks to Climaveneta as unique project leader. Complete and specialized Organization Climaveneta qualifies itself for the

H

LP

H

LP

55

NOTE(1) Water in-out 30/35°C (plant side), outdoor air temperatur

7°C b.s./ 6°C b.u.(2) Total input is obtained from compressor input and

fan input.(3) Water in-out 23/18°C (plant side), outdoor air temperature

35°C b.s.(4) Water in-out 40/45°C (plant side), outdoor air temperature

7°C b.s./ 6°C b.u.(5) Water in-out 12/7°C (plant side), outdoor air temperature

35°C b.s.

(6) Ci=Circulator; Ce=Centrifugal(7) Sound power level according to ISO 9614 and

Eurovent 8/1(8) Average sound pressure level above one reflecting

surface (Q=2) at 1 meter from the outside dimensionsof the unit.

* secondo Eurovent

Models 0011ms 0025ms 0031ms 0041ms 0031t 0041t 0051t 0061t 0091t

Nominal heating power (1) kW 6,30 7,40 11,2 14 10,9 14 15,9 17,9 25,10

Total absorbed power (2) kW 1,50 1,80 2,60 3,30 2,60 3,30 3,80 4,20 6

COP Eurovent * 4,20 4,11 4,31 4,24 4,19 4,24 4,18 4,26 4,18

COP EN14511 4,13 4,15 4,22 4,16 4,15 4,15 4,11 4,25 4,19

Cooling capacity (3) kW 7,20 8,30 12,3 15,7 11,7 15,8 17,7 20,2 29,2

Total absorbed power (2) kW 1,90 2,20 3,30 4,10 3,10 4,20 4,70 5,30 7,80

EER Eurovent * 3,79 3,77 3,73 3,83 3,77 3,76 3,77 3,81 3,74

EER EN 14511 3,82 3,82 3,81 3,84 3,84 3,81 3,81 3,81 3,85

Heating capacity (4) kW 6,10 7,30 10,8 13,6 10,6 13,8 15,4 17,5 24,60

Total absorbed power (2) kW 1,90 2,30 3,30 4,10 3,20 4,30 4,60 5,20 7,40

COP Eurovent * 3,21 3,17 3,27 3,32 3,31 3,21 3,35 3,37 3,32

Cooling capacity (5) kW 5,20 6,30 9,20 11,7 8,60 11,9 13,2 15,2 22,10

Total absorbed power (2) kW 1,70 2,20 3,10 4,00 3,00 4,00 4,60 5,00 7,20

EER Eurovent * 3,06 2,86 2,97 2,93 2,87 2,98 2,87 3,04 3,07

ESEER 3,62 3,63 3,52 3,46 3,42 3,65 3,24 3,55 3,57

Compressor type SCROLL

N. Compressors N. 1

Refrigerant R410A

N. fans N. 1 1 2 2 2 2 2 2 3

Plant side pump type (6) Ci Ci Ci Ci Ci Ci Ci Ci Ci

Electrical power supply V-Ph~Hz 230-1~50 230-1~50 230-1~50 230-1~50 400-3N~50 400-3N~50 400-3N~50 400-3N~50 400-3N~50

Start-up current A 27 30 45 45 48 64 64 75 111

Sound power (7) dB(A) 69 69 71 71 71 71 71 72 74

Sound pressure (8) dB(A) 54 54 56 56 56 56 56 57 58

DIMENSION

L mm 900 900 900 900 900 900 900 1550 1550

H mm 1240 1240 1240 1390 1240 1390 1390 1200 1700

P mm 420 420 420 420 420 420 420 450 450

Operational weight kg 145 150 155 170 155 170 180 250 335

Models 0011ms 0025ms 0031ms 0041ms 0031t 0041t 0051t 0061t 0091t

Nominal heating power (1) kW 6,30 7,40 11,2 14 10,9 14 15,9 17,9 25,10

Total absorbed power (2) kW 1,50 1,80 2,60 3,30 2,60 3,30 3,80 4,20 6

COP Eurovent * 4,20 4,11 4,31 4,24 4,19 4,24 4,18 4,26 4,18

COP EN14511 4,13 4,15 4,22 4,16 4,15 4,15 4,11 4,25 4,19

Cooling capacity (3) kW 7,20 8,30 12,3 15,7 11,7 15,8 17,7 20,2 29,2

Total absorbed power (2) kW 1,90 2,20 3,30 4,10 3,10 4,20 4,70 5,30 7,8

EER Eurovent * 3,79 3,77 3,73 3,83 3,77 3,76 3,77 3,81 3,74

EER EN 14511 3,82 3,82 3,81 3,84 3,84 3,81 3,81 3,81 3,85

Heating capacity (4) kW 6,10 7,30 10,8 13,6 10,6 13,8 15,4 17,5 24,6

Total absorbed power (2) kW 1,90 2,30 3,30 4,10 3,20 4,30 4,60 5,20 7,4

COP Eurovent * 3,21 3,17 3,27 3,32 3,31 3,21 3,35 3,37 3,32

Cooling capacity (5) kW 5,20 6,30 9,20 11,7 8,60 11,9 13,2 15,2 22,1

Total absorbed power (2) kW 1,70 2,20 3,10 4,00 3,00 4,00 4,60 5,00 7,2

EER Eurovent * 3,06 2,86 2,97 2,93 2,87 2,98 2,87 3,04 3,07

ESEER 3,62 3,63 3,52 3,46 3,42 3,65 3,24 3,55 3,57

Compressor type SCROLL

N. Compressors N. 1

Refrigerant R410A

N. fans N. 1 1 2 2 2 2 2 2 3

Plant side pump type (6) Ci Ci Ci Ci Ci Ci Ci Ci Ci

Electrical power supply V-Ph~Hz 230-1~50 230-1~50 230-1~50 230-1~50 400-3N~50 400-3N~50 400-3N~50 400-3N~50 400-3N~50

Start-up current A 27 30 45 45 48 64 64 75 111

Sound power (7) dB(A) 69 69 71 71 71 71 71 72 74

Sound pressure (8) dB(A) 54 54 56 56 56 56 56 57 58

DIMENSION

L mm 900 900 900 900 900 900 900 1550 1550

H mm 1240 1240 1240 1390 1240 1390 1390 1200 1700

P mm 420 420 420 420 420 420 420 450 450

Operational weight kg 145 150 155 170 155 170 180 250 335

AWR MTD XE

AWR MTD XE/H

Page 58: Products Guide V01 - ParagonEfficient project management thanks to Climaveneta as unique project leader. Complete and specialized Organization Climaveneta qualifies itself for the

56

PRANA

AW HT 0031ms÷0071ts

Versioni

AW HT High temperature air source heat pump for water heating up to 65°C, and operating limits down to -20° external air temperature

FeaturesStructure and base in hot-dip galvanised steel with epoxypowder coating finish.High-efficiency plate exchangers in AISI 316 stainless steelwith low pressure drops, fitted with heating element forfrost protection.High efficiency cycle EVI Hermetic Scroll Compressor (withhot gas direct injection into the compressor) to reach 65°C, with the crankcase heater and thermal protectionFinned coils made with copper pipes and aluminium finswith large exchange surface area (100% fully qualitytested); sub cooling circuit to prevent the icing at thebasementA condense collecting tray within water dischargeCoil protection grilleSoft starter for 230V/1/50Hz unitsThe water circuit comes complete with:

• Circulating pump for all models• Expansion tank• Safety valve• Manual filling assembly• Pressure gauge• Air vent valve• Outside air sensor wired

Main accessories• Three-way valve for domestic hot water• Buffer tank 35,100,200 liters• Hot water cylinder 300,500 liters• 300 litres thermal store for domestic hot water, for kit

DOMH2O• 300,500 litres thermal store for domestic hot water with

solar heat exchanger, for kit DOMH2O• DOMH2O15 e DOMH2O24 kit for domestic hot water

with external heat exchanger plate-to-plate and pump• Control kit for heat pump with boiler• 1,2,3 kw single-phase electric heater kit • Radiant panels or radiator management kit Second zone• Control kit for underfloor heating with hydronic

components• Removable metal mesh water filter kit• Rubber anti-vibration mounting kit• Room unit wired• Room thermostat wired based

Unit descriptionAW HT is an ideal solution for systems with heating radiators, where the water hightemperature is needed. The EVI technology compressor with additional steaminjection in the compressing cycle assures a water temperature of 65°C and operatinglimits as low as -20°C. Neither probes nor connections pipes to wells are needed; the

installation is simple, this is a suitable solution for all applications.

CommandsElectronic control provides great application flexibility. The remote keyboard kit wired indoor and outdoortemperature sensors allow dynamic control of delivery temperature water, optimizing comfort in the room andincreasing the energy efficienty. The electronic board PRO EXTENDED allows you to manage:- domestic hot water production by external three-way valve (accessory)- circulator on system side- a zone of direct heating- outdoor temperature sensor for water plant side modular set point compensation- electrical heating element for possible integration and anti-legionellosis cycle for cylinder- integrated boiler with heat pump- several solutions through appropriate configurations of the controller and use of dedicated extension

modules (accessories)

Heat pump, air source for outdoorinstallation, high water temperature10,4 ÷ 19,7 kW

Page 59: Products Guide V01 - ParagonEfficient project management thanks to Climaveneta as unique project leader. Complete and specialized Organization Climaveneta qualifies itself for the

57

NOTE(1) Water in-out 30/35°C (plant side), outdoor air temperature 7°C b.s./ 6°C b.u.(2) Total input is obtained from compressor input and fan input.(3) Water in-out 40/45°C (plant side), outdoor air temperature 7°C b.s./ 6°C b.u.(4) Water in-out 30/35°C (plant side), outdoor air temperature 2°C b.s./ 1°C b.u.(5) Water 65°C, outdoor air temperature -7°C b.s./ 1°C b.u.(6) Ci=Circulator; Ce=Centrifugal(7) Sound power level according to ISO 9614 and Eurovent 8/1(8) Average sound pressure level above one reflecting surface (Q=2) at 1 meter

from the outside dimensions of the unit.

Models 0031ms 0041ms 0041t 0061t 0071t 0041ts 0061ts 0071ts

Nominal heating power (1) kW 10,4 14,9 14,1 19,7 26,6 14,1 19,7 26,6

Total absorbed power (2) kW 2,50 3,50 3,30 4,70 6,1 3,30 4,70 6,1

COP EN14511 4,10 4,12 4,14 4,12 4,26 4,14 4,12 4,26

Heating capacity (3) kW 10,4 14,3 14,3 19,7 27,1 14,3 19,7 27,1

Total absorbed power (2) kW 3 4 4 5,60 7,4 4 5,60 7,4

COP EN14511 3,30 4,48 3,48 3,45 3,58 3,48 3,45 3,58

Heating capacity (4) kW 9,10 12,5 12,5 17,5 23,5 12,5 17,5 23,5

Total absorbed power (2) kW 2,50 3,30 3,30 4,60 5,9 3,30 4,60 5,9

COP EN 14511 3,44 3,66 3,66 3,72 3,88 3,66 3,72 3,88

Heating capacity (5) kW 7,80 11,4 11,4 14,8 21,2 11,4 14,8 21,2

Total absorbed power (2) kW 3,80 5,40 5,40 7,60 10,4 5,40 7,60 10,4

COP EN 14511 1,97 2,06 2,06 1,91 1,99 2,06 1,91 1,99

Compressor type SCROLL EVI

N. Compressors N. 1

Refrigerant R407C

N. fans N. 2 2 2 2 3 2 2 3

Plant side pump type (6) Ci

Electrical power supply V-Ph~Hz 230-1~50 230-1~50 400-3N~50 400-3N~50 400-3N~50 400-3N~50 400-3N~50 400-3N~50

Start-up current A 44 45 64 101 99 35 55 99

Sound power (7) dB(A) 70 70 70 71 74 70 71 74

Sound pressure (8) dB(A) 55 55 55 56 59 55 56 59

DIMENSION

L mm 900 900 900 900 1470 900 900 1470

H mm 1240 1390 1390 1390 1700 1390 1390 1700

P mm 420 420 420 420 570 420 420 570

Operational weight kg 150 160 160 170 320 160 170 320

AW HT

H

LP

Page 60: Products Guide V01 - ParagonEfficient project management thanks to Climaveneta as unique project leader. Complete and specialized Organization Climaveneta qualifies itself for the

58

PRANA

WWR MTD 0011m÷0121t

Versioni

WWR MTD High temperature air source heat pump for waterheating up to 65°C, and operating limits down to-20° external air temperature

FeaturesStructure and base in hot galvanised epoxy powder coatedsteel.High-efficiency plate exchangers in AISI 316 stainless steelwith low pressure drops, fitted with heating element for frostprotection.Hermetic scroll type compressors, equipped with thecrankcase heater and thermal protectionCase panels are insulated within low noise material forfurther improvement of silenceRubber vibration damper.Soft starter for 230V/1/50Hz units /msPhase sequence control relayThe water circuit comes complete with:Variable flow circulator for 0011÷0031 models andmultistage centrifugal variable flow pump for models0071÷0121, plant sideModulating valve to reduce water consumptions, sourceside

• Safety valve.• Expansion tank.• Manual filling assembly• Pressure gauge.• Air vent valve.• Drain valve on both plant and source circuits.• Differential pressure switch on source side and system

side

Main accessories• HSW12 remote keyboard• External temperature sensor (mandatory with HSW12

remote keyboard)• Three-way valve for domestic hot water• Buffer tank 35,100,200 liters• Hot water cylinder 300,500 liters• 300 litres thermal store for domestic hot water, for kit

DOMH2O• 300,500,1000 litres thermal store for domestic hot water

with solar heat exchanger, for kit DOMH2O• DOMH2O15 e DOMH2O24 kit for domestic hot water

with external heat exchanger plate-to-plate and pump• 1,2,3 kw single-phase electric heater kit

Unit descriptionThe MTD water-cooled heat pump are reversible units for heating, cooling anddomestic hot water by external three-way valve (accessory). Both heat pumps MTDare suitable for traditional heating systemsand radiant panels. The latter, working withwater at lower temperatures, ensure a higher yield and are a particularly appreciatedfor new buildings with low energy consumption that point on using renewable energyresources.The installation is greatly simplified through the integration of the group and hydraulictechnology Full floating simply by connecting the unit to water plant and electricity so

that it can be put into operation.

CommandsUser interface unit on board, accessible from the outside with a not touch system

Floating Set Once ever y 3 minutes an algorithm automatically optimises the water set point in relation to the

compressor operating time and the temperatures of the water in the system. He water storage tank is no longerindispensable because it is compensated by the Floating Set function, with resulting reduction in: size; weight;installation times; system setting-up times.

Floating Flow The controller manages the modulation of the active components (pump and electronic flow

valve) through pressure transducers and temperature sensors. The performance of the unit may thus be optimisedfor different operating conditions, such as traditional fan coil system and panel heating system, ensuring: broaderoperating limits; easier start-up of installations with both high and low water temperatures; faster system setup.The electronic menu allows to manage:- domestic hot water production by external three-way valve (accessory)- a zone of direct heating- circulator on system side and modulating valve- outdoor temperature sensor for water plant side modular set point compensation (accessory)

Reversible heat pump, water source7,2 ÷ 43,8 kW

Page 61: Products Guide V01 - ParagonEfficient project management thanks to Climaveneta as unique project leader. Complete and specialized Organization Climaveneta qualifies itself for the

59

Models 0011m 0021m 0025m 0031m 0041m 0011ms 0021ms 0025ms 0031ms 0041ms

Nominal heating power (1) kW 7,20 7,80 9,70 12,1 15,3 7,20 7,80 9,70 12,1 15,3

Total absorbed power (2) kW 1,40 1,49 1,81 2,30 2,88 1,40 1,49 1,81 2,30 2,88

COP * 5,14 5,23 5,36 5,26 5,31 5,14 5,23 5,36 5,26 5,31

Cooling capacity (3) kW 7,10 7,60 9,80 12 15,1 7,10 7,60 9,80 12 15,1

Total absorbed power (2) kW 1,60 1,70 2 2,50 3,30 1,60 1,70 1,96 2,53 3,27

EER * 4,44 4,47 4,90 4,80 4,58 4,44 4,47 5 4,74 4,62

Heating capacity (4) kW 6,80 7,50 9,20 11,6 14,6 6,80 7,50 9,20 11,6 14,6

Total absorbed power (2) kW 1,70 1,90 2,30 3 3,60 1,70 1,90 2,30 3 3,60

COP * 4 3,95 4 3,87 4,06 4 3,95 4 3,87 4,06

Cooling capacity (5) kW 5,20 5,60 7,20 8,80 11,3 5,20 5,60 7,20 8,80 11,3

Total absorbed power (2) kW 1,53 1,70 2 2,60 3,20 1,53 1,70 2 2,60 3,20

EER * 3,47 3,29 3,60 3,38 3,53 3,40 3,29 3,60 3,38 3,53

ESEER 4,03 3,73 4,26 3,95 3,90 4,03 3,73 4,26 3,95 3,90

Compressor type SCROLL

N. Compressors N. 1

Refrigerant R410A

Plant side pump type (6) Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci

Electrical power supply V-Ph~Hz 230-1~50

Start-up current A 58 61 82 97 130 26 27 37 44 59

Sound power (7) dB(A) 52 52 53 53 58 52 52 53 53 58

Sound pressure (8) dB(A) 38 38 39 39 44 38 38 39 39 44

DIMENSION

L mm 560

H mm 980

P mm 575

Operational weight kg 148 148 150 152 160 148 148 150 152 160

WWR MTD

Models 0021t 0025t 0031t 0041t 0051t 0061t 0071t 0091t 0101t 0121t

Nominal heating power (1) kW 7,80 9,80 12,1 15,9 18,1 21,1 26,2 30,5 35 43,8

Total absorbed power (2) kW 1,40 1,73 2,17 2,90 3,40 3,70 4,60 5,20 6 7,60

COP * 5,57 5,66 5,58 5,48 5,32 5,70 5,70 5,87 5,83 5,76

Cooling capacity (3) kW 7,60 9,50 12 15,7 18 21,3 26,9 30,7 34,8 44,8

Total absorbed power (2) kW 1,60 1,80 2,50 3,30 3,80 4,10 5,20 6 7 8,80

EER * 4,75 5,28 4,80 4,76 4,74 5,20 5,17 5,12 4,97 5,09

Heating capacity (4) kW 7,40 9,20 11,4 15,3 17,1 20 24,8 28,8 33 41,7

Total absorbed power (2) kW 1,90 2,20 2,70 3,70 4,20 4,60 5,80 6,40 7,60 9,50

COP * 3,89 4,18 4,22 4,14 4,07 4,35 4,28 4,50 4,34 4,39

Cooling capacity (5) kW 5,60 7,30 8,90 11,8 13,2 15,7 19,8 22,9 26 33,4

Total absorbed power (2) kW 1,60 1,90 2,40 3,20 3,80 4 5,10 5,80 6,80 8,39

EER * 3,50 3,84 3,71 3,70 3,47 3,93 3,88 3,95 3,82 3,98

ESEER 3,97 4,54 4,33 4,08 3,92 4,51 4,40 4,61 4,33 4,37

Compressor type SCROLL

N. Compressors N. 1

Refrigerant R410A

Plant side pump type (6) Ci Ci Ci Ci Ci Ci Ce Ce Ce Ce

Electrical power supply V-Ph~Hz 400-3N~50

Start-up current A 32 35 48 64 64 75 95 111 118 140

Sound power (7) dB(A) 52 52 52 58 58 59 66 66 70 70

Sound pressure (8) dB(A) 38 38 38 44 44 45 51 51 55 55

DIMENSION

L mm 560 560 560 560 560 560 680 680 680 680

H mm 980 980 980 980 980 980 1150 1150 1150 1150

P mm 575 575 575 575 575 575 780 780 780 780

Operational weight kg 148 150 152 160 170 175 220 230 235 250

WWR MTD

H

L P

NOTE(1) Condenser water in-out 30/35°C (plant side), Evaporator water in 10°C (source side)(2) Total input is obtained from compressor input and fan input.(3) Temperatura acqua impianto 23/18°C, temperatura acqua sorgente 30/35°C(4) Temperatura acqua impianto 40/45°C, temperatura acqua sorgente ingresso 10°C(5) Temperatura acqua impianto 12/7°C, temperatura acqua sorgente 30/35°C(6) Ci=Circulator; Ce=Centrifugal(7) Sound power level according to ISO 9614 and Eurovent 8/1(8) Average sound pressure level above one reflecting surface (Q=2) at 1 meter from the outside dimensions of the unit.* secondo Eurovent

Page 62: Products Guide V01 - ParagonEfficient project management thanks to Climaveneta as unique project leader. Complete and specialized Organization Climaveneta qualifies itself for the

60

PRANA

WWR HT Slim Z1M6÷Z1T11

Versioni

WWR HT Slim High temperature heat pump, water source for water heating up to 60°C, reversible

FeaturesStructure and base in hot galvanised epoxy powder coatedsteel.180-litre tank with built-in coil for domestic hot water, withfittings for connecting solar panels or hightemperaturefixtures (e.g. fan coils)High-efficiency plate exchangers in AISI 316 stainless steelwith low pressure drops, fitted with heating element for frostprotection.High-efficiency single-and three-phase SCROLL compressorto allow water up to 60 °C to be produced.Also suitable for traditional radiator systems.The compressor and plate heat exchangers are housed ina suitably insulated enclosure to limit vibrations and noise.This enclosure can be removed from the unit to makemaintenance easierCase panels are insulated within low noise material forfurther improvement of silenceRubber vibration damper.Soft starter for 230V/1/50Hz unitsPhase sequence control relayThe water circuit comes complete with:

• Circulator on system side• Three-way valve for domestic hot water• Safety valve• 180Xlt domestic hot water storage tank• Expansion tank built into the heat pumps tank• Manual filling assembly• Pressure gauge• Air vent valve• Drain valve• Differential pressure switch on source side and system

side• Outside air sensor wired

Main accessories• Room unit wired• Room thermostat wired based• Room unit wireless• Outside air sensor wireless• NTC probe for select plant diagram or solar panel• Heating element kit

Unit descriptionThe Prana Slim heat pump is designed for heating, cooling, and domestic hot water.It is an indoor unit with elegant design and thanks to a special sound insulation, the

unit is suitable for a living comfort.

CommandsElectronic control provides great application flexibility. The remote keyboard kit wired indoor and outdoortemperature sensors allow dynamic control of delivery temperature water, optimizing comfort in the room andincreasing the energy efficienty. The electronic board PRO EXTENDED allows you to manage:- domestic hot water production by three-way valve- circulator on system side- a zone of direct heating- zone with mix valve for floor heating- outdoor temperature sensor for water plant side modular set point compensation- integration by solar panels- several solutions through appropriate configurations of the controller

Reversible heat pump, water source, highwater temperature with buffer tank8,3 ÷ 14,1 kW

Page 63: Products Guide V01 - ParagonEfficient project management thanks to Climaveneta as unique project leader. Complete and specialized Organization Climaveneta qualifies itself for the

61

NOTE(1) Condenser water in-out 30/35°C (plant side), Evaporator water in 10°C (source side) with identical flow rate that in the

cooling mode(2) According to Eurovent(3) Evaporator water in-out 23/18°C (plant side), Condenser water in-out 30/35°C (source side)(4) Condenser water in-out 40/45°C (plant side), water in 10°C (source side) with identical flow rate that in the cooling mode(5) Evaporator water in-out 12/7°C (plant side), Condenser water in-out 30/35°C (source side)(6) Ci=Circulator; Ce=Centrifugal(7) Sound power level according to ISO 9614 and Eurovent 8/1(8) Average sound pressure level above one reflecting surface (Q=2) at 1 meter from the outside dimensions of the unit.

* secondo Eurovent

Models Z1M6 Z1M9 Z1M11 Z1T6 Z1T9 Z1T11

Nominal heating power (1) kW 8,30 11,6 14,1 8,20 11,4 14

Total absorbed power (2) kW 1,60 2,22 2,68 1,56 2,14 2,61

COP * 5,19 5,23 5,26 5,24 5,34 5,35

Cooling capacity (3) kW 9,55 13,2 15,5 9,36 12,9 15,6

Total absorbed power (2) kW 1,46 2,11 2,72 1,45 2,06 2,64

EER * 6,54 6,25 5,71 6,46 6,27 5,92

Heating capacity (4) kW 7,95 11,1 13,6 7,87 11 13,5

Total absorbed power (2) kW 2,02 2,80 3,37 1,98 2,72 3,27

COP * 3,94 3,96 4,02 3,97 4,04 4,11

Cooling capacity (5) kW 6,67 9,24 11,1 6,58 9,12 11,1

Total absorbed power (2) kW 1,53 2,17 2,67 1,49 2,09 2,59

EER * 4,36 4,26 4,16 4,42 4,36 4,28

Hot water tank l 180

Compressor type SCROLL

N. Compressors N. 1

Refrigerant R407C

Plant side pump type (6) Ci Ci Ci Ci Ci Ci

Electrical power supply V-Ph~Hz 230-1~50 230-1~50 230-1~50 400-3N~50 400-3N~50 400-3N~50

Start-up current A 37 60 68 32 46 50

Sound power (7) dB(A) 42 42 46 42 42 46

Sound pressure (8) dB(A) 28 28 32 28 28 32

DIMENSION

L mm 600

H mm 1940

P mm 570

Operational weight kg 286 293 300 286 293 300

WWR HT Slim

L

P

H

Page 64: Products Guide V01 - ParagonEfficient project management thanks to Climaveneta as unique project leader. Complete and specialized Organization Climaveneta qualifies itself for the

62

PRANA

WWR HT Cube Z1M6÷Z1T28

Versioni

WWR HT Cube High temperature heat pump, water source for water heating up to 60°C, reversible

FeaturesStructure and base in hot galvanised epoxy powder coatedsteel.High-efficiency plate exchangers in AISI 316 stainless steelwith low pressure drops, fitted with heating element for frostprotection.High-efficiency single-and three-phase SCROLLcompressor to allow water up to 60 °C to be produced.Also suitable for traditional radiator systems.The compressor and plate heat exchangers are housed in asuitably insulated enclosure to limit vibrations and noise.This enclosure can be removed from the unit to makemaintenance easierCase panels are insulated within low noise material forfurther improvement of silenceRubber vibration damper.Soft starter for 230V/1/50Hz unitsPhase sequence control relayThe water circuit comes complete with:

• Circulator on system side• Drain valve• Differential pressure switch on source side and system

side• Outside air sensor wired

Main accessories• Room unit wired• Room thermostat wired based• Room unit wireless• Outside air sensor wireless• NTC probe for select plant diagram or solar panel• Heating element kit• Three-way valve for domestic hot water• Buffer tank 35,100,200 liters• Hot water cylinder 300,500 liters• 300 litres thermal store for domestic hot water, for kit

DOMH2O• 300,500,1000 litres thermal store for domestic hot water

with solar heat exchanger, for kit DOMH2O• DOMH2O15 e DOMH2O24 kit for domestic hot water

with external heat exchanger plate-to-plate and pump

Unit descriptionThe Prana Cube heat pump is designed for heating, cooling, and domestic hot water,with external three-way valve. It is an indoor unit with elegant design and thanks to a

special sound insulation, the unit is suitable for a living comfort.

CommandsElectronic control provides great application flexibility. The remote keyboard kit wired indoor and outdoortemperature sensors allow dynamic control of delivery temperature water, optimizing comfort in the room andincreasing the energy efficienty. The electronic board PRO EXTENDED allows you to manage:- domestic hot water production by external three-way valve (accessory)- circulator on system side- a zone of direct heating- zone with mix valve for floor heating- outdoor temperature sensor for water plant side modular set point compensation- integration by solar panels- several solutions through appropriate configurations of the controller

Reversible heat pump, water source,high water temperature8,3 ÷ 35,9 kW

Page 65: Products Guide V01 - ParagonEfficient project management thanks to Climaveneta as unique project leader. Complete and specialized Organization Climaveneta qualifies itself for the

63

Models Z1M6 Z1M9 Z1M11 Z1T6 Z1T9 Z1T11 Z1T13 Z1T17 Z1T24 Z1T28

Nominal heating power (1) kW 8,30 11,6 14,1 8,20 11,4 14 17,1 22,6 31,1 35,9

Total absorbed power (2) kW 1,60 2,22 2,68 1,56 2,14 2,61 3,28 4,30 5,84 6,59

COP * 5,19 5,23 5,26 5,24 5,34 5,35 5,22 5,27 5,33 5,45

Cooling capacity (3) kW 9,55 13,2 15,5 9,36 12,9 15,6 19 24,9 34,7 40

Total absorbed power (2) kW 1,46 2,11 2,72 1,45 2,06 2,64 3,76 4,95 6,14 7

EER * 6,54 6,25 5,71 6,46 6,27 5,92 5,04 5,02 5,65 5,71

Heating capacity (4) kW 7,95 11,1 13,6 7,87 11 13,5 16,4 21,8 29,9 34,5

Total absorbed power (2) kW 2,02 2,80 3,37 1,98 2,72 3,27 4,07 5,39 7,28 8,29

COP * 3,94 3,96 4,02 3,97 4,04 4,11 4,02 4,04 4,11 4,16

Cooling capacity (5) kW 6,67 9,24 11,1 6,58 9,12 11,1 13,4 17,5 24,3 28,2

Total absorbed power (2) kW 1,53 2,17 2,67 1,49 2,09 2,59 3,38 4,53 6,01 6,77

EER * 4,36 4,26 4,16 4,42 4,36 4,28 3,97 3,87 4,05 4,16

Compressor type SCROLL

N. Compressors N. 1

Refrigerant R407C

Plant side pump type (6) Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci

Electrical power supply V-Ph~Hz 230-1~50 230-1~50 230-1~50 400-3N~50 400-3N~50 400-3N~50 400-3N~50 400-3N~50 400-3N~50 400-3N~50

Start-up current A 37 60 68 32 46 50 66 101 123 127

Sound power (7) dB(A) 42 42 46 42 42 46 47 51 55 55

Sound pressure (8) dB(A) 28 28 32 28 28 32 33 37 41 41

DIMENSION

L mm 600 600 600 600 600 600 600 600 900 900

H mm 940 940 940 940 940 940 940 940 1117 1117

P mm 570 570 570 570 570 570 570 570 648 648

Operational weight kg 160 180 190 160 180 190 200 220 240 250

WWR HT Cube

NOTE(1) Condenser water in-out 30/35°C (plant side), Evaporator water in 10°C (source side) with identical flow rate that in the

cooling mode(2) According to Eurovent(3) Evaporator water in-out 23/18°C (plant side), Condenser water in-out 30/35°C (source side)(4) Condenser water in-out 40/45°C (plant side), water in 10°C (source side) with identical flow rate that in the cooling mode(5) Evaporator water in-out 12/7°C (plant side), Condenser water in-out 30/35°C (source side)(6) Ci=Circulator; Ce=Centrifugal(7) Sound power level according to ISO 9614 and Eurovent 8/1(8) Average sound pressure level above one reflecting surface (Q=2) at 1 meter from the outside dimensions of the unit.

* secondo Eurovent

H

L

P

Page 66: Products Guide V01 - ParagonEfficient project management thanks to Climaveneta as unique project leader. Complete and specialized Organization Climaveneta qualifies itself for the

64

PRANA

WWR DHW 0011m÷0121t

Versioni

WWR MTD Water source reversible heat pump with domestic hot water supply with total heat recovery

FeaturesStructure and base in hot galvanised epoxy powder coatedsteelCase panels are insulated within low noise material forfurther improvement of silenceRubber vibration damperHermetic scroll type compressors, equipped with thecrankcase heater and thermal protectionStainless steel (AISI 316) with high efficiency and lowpressure drop plate to plate exchanger (at the domestic hotwater side). It is positioned next after the compressor, itensures the domestic hot water production. That can workeither in full recovery or in part, with the constantoptimization of efficiency through logic advanced adjustingcontrollerExchangers plant side plate of stainless steel AISI 316 withhigh efficiency and low pressure drop meets the supply ofboth hot or cold water for the facility, regardless of thedomestic hot waterHigh efficiency and low pressure drop stainless steel (AISI316) source side plate exchangerSoft starter for 230V/1/50Hz units /msThe water circuit comes complete with:

• Variable flow circulator for 0011÷0031 models and multistage centrifugal variable flow pump for models 0071÷0121, plant side

• Domestic hot water, water side, variable flow pump• Modulating valve to reduce water consumptions,

source side• Safety valve• Expansion tank• Drain valve on both plant and source circuits

Main accessories• Buffer tank 35,100,200 liters• Hot water cylinder 300,500 liters• 300 litres thermal store for domestic hot water, for kit

DOMH2O• 300,500,1000 litres thermal store for domestic hot water

with solar heat exchanger, for kit DOMH2O• DOMH2O15 e DOMH2O24 kit for domestic hot water

with external heat exchanger plate-to-plate and pump• Remote keyboard• Removable metal mesh water filter kit

Unit descriptionPRANA DHW is the heat pump new generation able to operate throughout the year inany operating mode: either a single cycle (air conditioning, heating, hot water) andcombined cycle (hot water along with air conditioning or heating). Energy efficiency ishighest during the summer cycle, when, thanks to the full recovery of the heat, theproduction of hot water is free. During the combined use, the DHW exchanger usesthe temperature of the hot exhaust gases to gets inside the accumulation sanitarywater as high as 65° C. The advanced CLIMAVENETA fully patented electronic ensuresthe highest flexibility of operation, a rapid speed and a significant increase in the overallCOP, which go hand in hand with electricity and space reduction. Advantages,combined with the possibility of completely eliminating the traditional boiler, makingheat pumps PRANA DHW the ideal solution for energy saving applications in

residential, hotel and small sector.

CommandsUser interface unit on board, accessible from the outside with a not touch systemWWR-DHW heats water stored in the tank as energy storage. It also comes with a state-of-the-art electronic unit,which independently controls the modes of operation. The appliance can operate throughout the year in anymode, both with single cycle (cooling, heating, hot water) and with combined cycle (hot water together withcooling or hot water together heating).During the summer cycle there is maximum energy saving through total heatrecovery. This energy is completely free of charge with regard to the production of hot water.

Reversible heat pump, total heatrecovery, water source6,0 ÷ 40,5 kW

Page 67: Products Guide V01 - ParagonEfficient project management thanks to Climaveneta as unique project leader. Complete and specialized Organization Climaveneta qualifies itself for the

65

Models 0011m 0021m 0025m 0031m 0041m 0011ms 0021ms 0025ms 0031ms 0041msNominal heating power (1) kW 6 7,60 9 10,5 12,9 6 7,60 9 10,5 12,9Total absorbed power (2) kW 1,30 1,70 2 2,40 2,90 1,30 1,70 2 2,40 2,90COP 4,49 4,48 4,51 4,36 4,50 4,49 4,48 4,51 4,36 4,50Cooling capacity (3) kW 7,30 9,20 11 12,5 15,3 7,30 9,20 11 12,5 15,3Total absorbed power (2) kW 1,30 1,70 2 2,40 2,90 1,30 1,70 2 2,40 2,90EER 5,62 5,41 5,50 5,21 5,28 5,62 5,41 5,50 5,21 5,28Total absorbed power (4) kW 6 7,80 9,20 10,3 12,9 6 7,80 9,20 10,3 12,9Total absorbed power kW 1,90 2,40 2,90 3,40 4,20 1,90 2,40 2,90 3,40 4,20Recovery heating capacity (4) kW 7,90 10 11,9 13,5 16,8 7,90 10 11,9 13,5 16,8Heating capacity (5) kW 5,70 7,30 8,70 10,1 12,4 5,60 7,20 8,50 9,90 12,2Total absorbed power (2) kW 1,70 2,20 2,60 3,10 3,60 1,70 2,20 2,60 3,10 3,60COP 3,33 3,35 3,37 3,28 3,40 3,33 3,35 3,37 3,28 3,40Cooling capacity (6) kW 5,10 6,50 7,70 8,90 11 5,10 6,50 7,70 8,90 11Total absorbed power (2) kW 1,30 1,70 2 2,40 2,90 1,30 1,70 2 2,40 2,90EER 3,92 3,82 3,85 3,71 3,79 3,92 3,82 3,85 3,71 3,79Compressor type SCROLLN. Compressors N. 1Refrigerant R407CPlant side pump type (7) Ci Ci Ci Ci Ci Ci Ci Ci Ci CiRecovery side pump type (7) Ci Ci Ci Ci Ci Ci Ci Ci Ci CiElectrical power supply V-Ph~Hz 230-1~50 230-1~50 230-1~50 230-1~50 230-1~50 230-1~50 230-1~50 230-1~50 230-1~50 230-1~50Start-up current A 47 61 76 100 114 21 27 34 45 51Sound power (8) dB(A) 52 52 53 53 58 52 52 53 53 58Sound pressure (9) dB(A) 38 38 39 39 44 38 38 39 39 44DIMENSIONL mm 560 560 560 560 560 560 560 560 560 560H mm 980 980 980 980 980 980 980 980 980 980P mm 575 575 575 575 575 575 575 575 575 575Operational weight kg 188 188 190 195 215 188 188 190 195 215

WWR DHW

Models 0021t 0025t 0031t 0041t 0051t 0061t 0071t 0091t 0101t 0121tNominal heating power (1) kW 7,50 8,90 10,3 12,7 15,6 18,7 25,3 28,4 32,6 40,5Total absorbed power (2) kW 1,70 2 2,30 2,80 3,40 3,90 5,30 5,90 6,90 8,80COP 4,55 4,58 4,44 4,57 4,58 4,75 4,73 4,84 4,69 4,59Cooling capacity (3) kW 9,20 10,9 12,4 15,4 19,1 22,5 30,2 34,4 38,9 49,7Total absorbed power (2) kW 1,60 1,90 2,30 2,80 3,60 4,10 5,50 6,10 7,30 9,30EER 5,75 5,74 5,39 5,50 5,31 5,49 5,49 5,64 5,33 5,34Total absorbed power (4) kW 7,70 9,10 10,3 13,1 16 18,9 25,5 29 32,7 41,1Total absorbed power kW 2,30 2,80 3,30 4 4,90 5,70 7,70 8,40 10,2 12,8Recovery heating capacity (4) kW 9,90 11,7 13,4 16,9 20,6 24,2 32,7 36,9 42,4 53,1Heating capacity (5) kW 7,20 8,60 9,90 12,3 14,9 17,9 24 27,1 31,1 38,3Total absorbed power (2) kW 2,10 2,50 3 3,50 4,30 4,90 6,80 7,30 8,70 11,1COP 3,41 3,42 3,34 3,48 3,50 3,62 3,55 3,69 3,55 3,45Cooling capacity (6) kW 6,50 7,70 8,80 10,9 13,4 16,1 21,7 24,6 28 34,8Total absorbed power (2) kW 1,70 2 2,30 2,80 3,40 4 5,40 5,90 7 8,90EER 3,82 3,85 3,83 3,89 3,94 4,03 4,02 4,17 4,00 3,91Compressor type SCROLLN. Compressors N. 1Refrigerant R407CPlant side pump type (7) Ci Ci Ci Ci Ci Ce Ce Ce Ce CeRecovery side pump type (7) Ci Ci Ci Ci Ci Ci Ci Ci Ci CiElectrical power supply V-Ph~Hz 400-3N~50Start-up current A 32 40 46 50 66 74 95 111 118 140Sound power (8) dB(A) 52 52 52 58 58 59 66 66 70 70Sound pressure (9) dB(A) 38 38 38 44 44 45 51 51 55 55DIMENSIONL mm 560 560 560 560 560 560 680 680 680 680H mm 980 980 980 980 980 980 1150 1150 1150 1150P mm 575 575 575 575 575 575 780 780 780 780Operational weight kg 188 190 195 215 228 233 260 270 280 305

H

L P

NOTE(1) Condenser water in-out 30/35°C (plant side), Evaporator water in 10°C (source side) with identical flow rate that in the cooling mode(2) According to Eurovent(3) Evaporator water in-out 23/18°C (plant side), Condenser water in-out 30/35°C (source side)(4) Water in-out 23/18°C (plant side), water in-out 45/50°C (total recovery side)(5) Condenser water in-out 40/45°C (plant side), water in 10°C (source side) with identical flow rate that in the cooling mode(6) Evaporator water in-out 12/7°C (plant side), Condenser water in-out 30/35°C (source side)(7) Ci=Circulator; Ce=Centrifugal(8) Sound power level according to ISO 9614 and Eurovent 8/1(9) Average sound pressure level above one reflecting surface (Q=2) at 1 meter from the outside dimensions of the unit.

Page 68: Products Guide V01 - ParagonEfficient project management thanks to Climaveneta as unique project leader. Complete and specialized Organization Climaveneta qualifies itself for the

66

PRANA

BWR MTD 0011m÷0121t

Versioni

BWR MTD Medium temperature geothermal reversible heat pump for water heating up to 55°C

FeaturesStructure and base in hot galvanised epoxy powdercoated steel.High-efficiency plate exchangers in AISI 316 stainlesssteel with low pressure drops, fitted with heating elementfor frost protection.Hermetic scroll type compressors, equipped with thecrankcase heater and thermal protectionCase panels are insulated within low noise material forfurther improvement of silenceRubber vibration damper.Soft starter for 230V/1/50Hz units /msPhase sequence control relayThe water circuit comes complete with:

• Variable flow circulator for 0011÷0031 models and multistage centrifugal variable flow pump for models 0071÷0121, plant side

• Variable flow circulator for 0011÷0031 models, multistage centrifugal variable flow pump for models 0071-0121 on source side (for geothermal systems, closed vertical or horizontal loops)

• Safety valve.• Expansion tank.• Manual filling assembly• Pressure gauge.• Air vent valve.• Drain valve on both plant and source circuits.• Differential pressure switch on source side and

system side

Main accessories• HSW12 remote keyboard• External temperature sensor (mandatory with HSW12

remote keyboard)• Three-way valve for domestic hot water• Buffer tank 35,100,200 liters• Hot water cylinder 300,500 liters• 300 litres thermal store for domestic hot water, for kit

DOMH2O• 300,500,1000 litres thermal store for domestic hot

water with solar heat exchanger, for kit DOMH2O• DOMH2O15 e DOMH2O24 kit for domestic hot water

with external heat exchanger plate-to-plate and pump• 1,2,3 kw single-phase electric heater kit

Unit descriptionThe MTD heat pump optimized for geothermal systems are reversible units for heating,cooling and domestic hot water by external three-way valve (accessory). Both heatpumps MTD are suitable for traditional heating systemsand radiant panels. The latter,working with water at lower temperatures, ensure a higher yield and are a particularlyappreciated for new buildings with low energy consumption that point on usingrenewable energy resources.The installation is greatly simplified through the integration of the group and hydraulictechnology Full floating simply by connecting the unit to water plant and electricity so

that it can be put into operation.

CommandsUser interface unit on board, accessible from the outside with a not touch system

Floating Set Once ever y 3 minutes an algorithm automatically optimises the water set point in relation to the

compressor operating time and the temperatures of the water in the system. he water storage tank is no longerindispensable because it is compensated by the Floating Set function, with resulting reduction in: size; weight;installation times; system setting-up times.

Floating Flow The controller manages the modulation of the active components (pump and electronic flow

valve) through pressure transducers and temperature sensors. The performance of the unit may thus be optimisedfor different operating conditions, such as traditional fan coil system and panel heating system, ensuring: broaderoperating limits; easier start-up of installations with both high and low water temperatures; faster system setup.The electronic menu allows to manage:- domestic hot water production by external three-way valve (accessory)- a zone of direct heating- circulator on system and source side- outdoor temperature sensor for water plant side modular set point compensation (accessory)

Reversible heat pump,geothermal source5,4 ÷ 33,3 kW

Page 69: Products Guide V01 - ParagonEfficient project management thanks to Climaveneta as unique project leader. Complete and specialized Organization Climaveneta qualifies itself for the

67

Models 0011m 0021m 0025m 0031m 0041m 0011ms 0021ms 0025ms 0031ms 0041ms

Nominal heating power (1) kW 5,40 5,90 7,30 9,20 11,7 5,40 5,90 7,30 9,20 11,7

Total absorbed power (2) kW 1,34 1,50 1,82 2,35 2,80 1,34 1,50 1,82 2,35 2,80

COP * 4,03 3,93 4 3,92 4,18 4,03 3,93 4 3,92 4,18

Cooling capacity (3) kW 7,10 7,60 9,80 12 15,1 7,10 7,60 9,80 12 15,1

Total absorbed power (2) kW 1,60 1,70 1,96 2,53 3,27 1,60 1,70 1,96 2,53 3,27

EER * 4,44 4,47 5 4,74 4,62 4,44 4,47 5 4,74 4,62

Heating capacity (4) kW 5,20 5,70 7,10 9 11,3 5,20 5,70 7,10 9 11,3

Total absorbed power (2) kW 1,70 1,90 2,30 3 3,60 1,70 1,90 2,30 3 3,60

COP * 3,06 3 3,09 3 3,14 3,06 3 3,09 3 3,14

Cooling capacity (5) kW 5,20 5,60 7,20 8,80 11,3 5,20 5,60 7,20 8,80 11,3

Total absorbed power (2) kW 1,53 1,70 2 2,60 3,20 1,53 1,70 2 2,60 3,20

EER * 3,40 3,29 3,60 3,38 3,53 3,40 3,29 3,60 3,38 3,53

ESEER 4,03 3,73 4,26 3,95 3,90 4,03 3,73 4,26 3,95 3,90

Compressor type SCROLL

N. Compressors N. 1

Refrigerant R410A

Plant side pump type (6) Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci

Source side pump type (6) Ci Ci Ci Ci Ce Ci Ci Ci Ci Ce

Electrical power supply V-Ph~Hz 230-1~50

Start-up current A 58 61 82 97 130 26 27 37 44 59

Sound power (7) dB(A) 52 52 53 53 58 52 52 53 53 58

Sound pressure (8) dB(A) 38 38 39 39 44 38 38 39 39 44

DIMENSION

L mm 560

H mm 980

P mm 575

Operational weight kg 148 148 150 152 160 148 148 150 152 160

Models 0021t 0025t 0031t 0041t 0051t 0061t 0071t 0091t 0101t 0121t

Nominal heating power (1) kW 5,90 7,50 9,10 12,2 13,7 16 19,8 23 26,5 33,3

Total absorbed power (2) kW 1,40 1,74 2,10 2,80 3,40 3,50 4,40 4,90 5,80 7,30

COP * 4,21 4,31 4,33 4,36 4,03 4,57 4,50 4,69 4,57 4,56

Cooling capacity (3) kW 7,60 9,50 12 15,7 18 21,3 26,9 30,7 34,8 44,8

Total absorbed power (2) kW 1,60 1,84 2,50 3,30 3,70 4,10 5,15 5,95 7 8,80

EER * 4,75 5,16 4,80 4,76 4,86 5,20 5,22 5,16 4,97 5,09

Heating capacity (4) kW 5,70 7 8,70 11,8 12,9 15,2 18,8 21,8 25,1 31,9

Total absorbed power (2) kW 1,90 2,20 2,70 3,70 4,10 4,40 5,60 6,20 7,40 9

COP * 3 3,18 3,22 3,19 3,15 3,45 3,36 3,52 3,39 3,54

Cooling capacity (5) kW 5,60 7,30 8,90 11,8 13,2 15,7 19,8 22,9 26 33,4

Total absorbed power (2) kW 1,63 1,90 2,41 3,19 3,80 4 5,10 5,80 6,80 8,40

EER * 3,44 3,84 3,69 3,70 3,47 3,93 3,88 3,95 3,82 3,98

ESEER 3,97 4,54 4,33 4,08 3,92 4,51 4,40 4,61 4,33 4,37

Compressor type SCROLL

N. Compressors N. 1

Refrigerant R410A

Plant side pump type (6) Ci Ci Ci Ci Ci Ci Ce Ce Ce Ce

Source side pump type (6) Ci Ci Ci Ce Ce Ce Ce Ce Ce Ce

Electrical power supply V-Ph~Hz 400-3N~50

Start-up current A 32 35 48 64 64 75 95 111 118 140

Sound power (7) dB(A) 52 52 52 58 58 59 66 66 70 70

Sound pressure (8) dB(A) 38 38 38 44 44 45 51 51 55 55

DIMENSION

L mm 560 560 560 560 560 560 680 680 680 680

H mm 980 980 980 980 980 980 1150 1150 1150 1150

P mm 575 575 575 575 575 575 780 780 780 780

Operational weight kg 148 150 152 160 170 175 220 230 235 250

BWR MTD

H

L P

NOTE(1) Condenser water in-out 30/35°C (plant side), Evaporator water in-out 0/-3°C (source side)(2) According to Eurovent(3) Evaporator water in-out 23/18°C (plant side), Condenser water in-out 30/35°C (source side)(4) Condenser water in-out 40/45°C (plant side), Evaporator water in-out 0/-3°C (source side)(5) Evaporator water in-out 12/7°C (plant side), Condenser water in-out 30/35°C (source side)(6) Ci=Circulator; Ce=Centrifugal(7) Sound power level according to ISO 9614 and Eurovent 8/1(8) Average sound pressure level above one reflecting surface (Q=2) at 1 meter from the outside dimensions of the unit.

* secondo Eurovent

Page 70: Products Guide V01 - ParagonEfficient project management thanks to Climaveneta as unique project leader. Complete and specialized Organization Climaveneta qualifies itself for the

68

PRANA

BWR HT Slim Z1M6÷Z1T11

Versioni

BWR HT Slim High temperature heat pump, geothermal source, for water heating up to 60°C, reversible

FeaturesStructure and base in hot galvanised epoxy powder coatedsteel180-litre tank with built-in coil for domestic hot water, withfittings for connecting solar panels or hightemperature fixtures(e.g. fan coils)High-efficiency plate exchangers in AISI 316 stainless steelwith low pressure drops, fitted with heating element for frostprotectionHigh-efficiency single-and three-phase SCROLL compressorto allow water up to 60 °C to be producedAlso suitable for traditional radiator systemsThe compressor and plate heat exchangers are housed in asuitably insulated enclosure to limit vibrations and noise. Thisenclosure can be removed from the unit to makemaintenance easierCase panels are insulated within low noise material for furtherimprovement of silenceRubber vibration damperSoft starter for 230V/1/50Hz unitsPhase sequence control relayThe water circuit comes complete with:

• Circulator on system side• Circulator on source side (for geothermal systems,

closed vertical or horizontal loops)• Three-way valve for domestic hot water• 180Xlt domestic hot water storage tank• Safety valve• Expansion tank built into the heat pumps tank• Manual filling assembly• Pressure gauge• Drain valve• Air vent valve• Differential pressure switch on source side and system

side• Outside air sensor wired

Main accessories• Room unit wired• Room thermostat wired based• Room unit wireless• Outside air sensor wireless• NTC probe for select plant diagram or solar panel• Heating element kit

Unit descriptionThe Prana Slim heat pump is designed for heating, cooling, and domestic hot water.It is an indoor unit with elegant design and thanks to a special sound insulation, the

unit is suitable for a living comfort.

CommandsElectronic control provides great application flexibility. The remote keyboard kit wired indoor and outdoortemperature sensors allow dynamic control of delivery temperature water, optimizing comfort in the room andincreasing the energy efficienty. The electronic board PRO EXTENDED allows you to manage:- domestic hot water production by three-way valve- circulator on system and source side- a zone of direct heating- zone with mix valve for floor heating- outdoor temperature sensor for water plant side modular set point compensation- integration by solar panels- several solutions through appropriate configurations of the controller

Reversible heat pump, geothermal source,high water temperature with buffer tank6,2 ÷ 10,6 kW

Page 71: Products Guide V01 - ParagonEfficient project management thanks to Climaveneta as unique project leader. Complete and specialized Organization Climaveneta qualifies itself for the

69

NOTE(1) Condenser water in-out 30/35°C (plant side), Evaporator water in-out 0/-3°C (source side)(2) According to Eurovent(3) Evaporator water in-out 23/18°C (plant side), Condenser water in-out 30/35°C (source side)(4) Condenser water in-out 40/45°C (plant side), Evaporator water in-out 0/-3°C (source side)(5) Evaporator water in-out 12/7°C (plant side), Condenser water in-out 30/35°C (source side)(6) Ci=Circulator; Ce=Centrifugal(7) Sound power level according to ISO 9614 and Eurovent 8/1(8) Average sound pressure level above one reflecting surface (Q=2) at 1 meter from the outside dimensions of the unit.

* secondo Eurovent

Models Z1M6 Z1M9 Z1M11 Z1T6 Z1T9 Z1T11

Nominal heating power (1) kW 6,21 8,66 10,6 6,04 8,43 10,5

Total absorbed power (2) kW 1,60 2,22 2,68 1,55 2,13 2,60

COP * 3,88 3,90 3,96 3,90 3,96 4,02

Cooling capacity (3) kW 9,55 13,2 15,5 9,36 12,9 15,6

Total absorbed power (2) kW 1,46 2,11 2,72 1,45 2,06 2,64

EER * 6,54 6,25 5,71 6,46 6,27 5,92

Heating capacity (4) kW 6,04 8,41 10,3 5,89 8,20 10,2

Total absorbed power (2) kW 2,02 2,80 3,35 1,97 2,71 3,24

COP * 2,99 3 3,08 2,99 3,03 3,14

Cooling capacity (5) kW 6,67 9,24 11,1 6,58 9,12 11,1

Total absorbed power (2) kW 1,53 2,17 2,67 1,49 2,09 2,59

EER * 4,36 4,26 4,16 4,42 4,36 4,28

Hot water tank l 180

Compressor type SCROLL

N. Compressors N. 1

Refrigerant R407C

Plant side pump type (6) Ci Ci Ci Ci Ci Ci

Source side pump type (6) Ci Ci Ci Ci Ci Ci

Electrical power supply V-Ph~Hz 230-1~50 230-1~50 230-1~50 400-3N~50 400-3N~50 400-3N~50

Start-up current A 37 60 68 32 46 50

Sound power (7) dB(A) 42 42 46 42 42 46

Sound pressure (8) dB(A) 28 28 32 28 28 32

DIMENSION

L mm 600

H mm 1940

P mm 570

Operational weight kg 286 293 300 286 293 300

BWR HT Slim

L

P

H

Page 72: Products Guide V01 - ParagonEfficient project management thanks to Climaveneta as unique project leader. Complete and specialized Organization Climaveneta qualifies itself for the

70

PRANA

BWR HT Cube Z1M6÷Z1T28

Versioni

BWR HT Cube High temperature heat pump, geothermal source, for water heating up to 60°C, reversible

FeaturesStructure and base in hot galvanised epoxy powder coatedsteelHigh-efficiency plate exchangers in AISI 316 stainless steelwith low pressure drops, fitted with heating element for frostprotectionHigh-efficiency single-and three-phase SCROLL compressorto allow water up to 60 °C to be producedAlso suitable for traditional radiator systemsThe compressor and plate heat exchangers are housed in asuitably insulated enclosure to limit vibrations and noise. Thisenclosure can be removed from the unit to makemaintenance easierCase panels are insulated within low noise material for furtherimprovement of silenceRubber vibration damperSoft starter for 230V/1/50Hz unitsPhase sequence control relayThe water circuit comes complete with:

• Circulator on system side• Circulator on source side (for geothermal systems,

closed vertical or horizontal loops)• Drain valve• Differential pressure switch on source side and system

side• Outside air sensor wired

Main accessories• Room unit wired• Room thermostat wired based• Room unit wireless• Outside air sensor wireless• NTC probe for select plant diagram or solar panel• Heating element kit• Three-way valve for domestic hot water• Buffer tank 35,100,200 liters• Hot water cylinder 300,500 liters• 300 litres thermal store for domestic hot water, for kit

DOMH2O• 300,500,1000 litres thermal store for domestic hot water

with solar heat exchanger, for kit DOMH2O• DOMH2O15 e DOMH2O24 kit for domestic hot water

with external heat exchanger plate-to-plate and pump

Unit descriptionThe Prana Cube heat pump is designed for heating, cooling, and domestic hot water,with external three-way valve. It is an indoor unit with elegant design and thanks to a

special sound insulation, the unit is suitable for a living comfort.

CommandsElectronic control provides great application flexibility. The remote keyboard kit wired indoor and outdoortemperature sensors allow dynamic control of delivery temperature water, optimizing comfort in the room andincreasing the energy efficienty. The electronic board PRO EXTENDED allows you to manage:- domestic hot water production by three-way valve- circulator on system and source side- a zone of direct heating- zone with mix valve for floor heating- outdoor temperature sensor for water plant side modular set point compensation- integration by solar panels- several solutions through appropriate configurations of the controller

Reversible heat pump, geothermal source,high water temperature6,2 ÷ 27,0 kW

Page 73: Products Guide V01 - ParagonEfficient project management thanks to Climaveneta as unique project leader. Complete and specialized Organization Climaveneta qualifies itself for the

71

Models Z1M6 Z1M9 Z1M11 Z1T6 Z1T9 Z1T11 Z1T13 Z1T17 Z1T24 Z1T28

Nominal heating power (1) kW 6,21 8,66 10,6 6,04 8,43 10,5 12,6 16,9 23,3 27

Total absorbed power (2) kW 1,60 2,22 2,68 1,55 2,13 2,60 3,17 4,14 5,74 6,53

COP * 3,88 3,90 3,96 3,90 3,96 4,02 3,96 4,09 4,06 4,14

Cooling capacity (3) kW 9,55 13,2 15,5 9,36 12,9 15,6 19 24,9 34,7 40

Total absorbed power (2) kW 1,46 2,11 2,72 1,45 2,06 2,64 3,76 4,95 6,14 7

EER * 6,54 6,25 5,71 6,46 6,27 5,92 5,04 5,02 5,65 5,71

Heating capacity (4) kW 6,04 8,41 10,3 5,89 8,20 10,2 12,2 16,4 22,6 26,2

Total absorbed power (2) kW 2,02 2,80 3,35 1,97 2,71 3,24 3,94 5,24 7,12 8,12

COP * 2,99 3 3,08 2,99 3,03 3,14 3,09 3,14 3,18 3,23

Cooling capacity (5) kW 6,67 9,24 11,1 6,58 9,12 11,1 13,4 17,5 24,3 28,2

Total absorbed power (2) kW 1,53 2,17 2,67 1,49 2,09 2,59 3,38 4,53 6,01 6,77

EER * 4,36 4,26 4,16 4,42 4,36 4,28 3,97 3,87 4,05 4,16

Compressor type SCROLL

N. Compressors N. 1

Refrigerant R407C

Plant side pump type (6) Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci

Source side pump type (6) Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci

Electrical power supply V-Ph~Hz 230-1~50 230-1~50 230-1~50 400-3N~50 400-3N~50 400-3N~50 400-3N~50 400-3N~50 400-3N~50 400-3N~50

Start-up current A 37 60 68 32 46 50 66 101 123 127

Sound power (7) dB(A) 42 42 46 42 42 46 47 51 55 55

Sound pressure (8) dB(A) 28 28 32 28 28 32 33 37 41 41

DIMENSION

L mm 600 600 600 600 600 600 600 600 900 900

H mm 940 940 940 940 940 940 940 940 1117 1117

P mm 570 570 570 570 570 570 570 570 648 648

Operational weight kg 160 180 190 160 180 190 200 220 240 250

BWR HT Cube

NOTE(1) Condenser water in-out 30/35°C (plant side), Evaporator water in-out 0/-3°C (source side)(2) According to Eurovent(3) Evaporator water in-out 23/18°C (plant side), Condenser water in-out 30/35°C (source side)(4) Condenser water in-out 40/45°C (plant side), Evaporator water in-out 0/-3°C (source side)(5) Evaporator water in-out 12/7°C (plant side), Condenser water in-out 30/35°C (source side)(6) Ci=Circulator; Ce=Centrifugal(8) Sound power level according to ISO 9614 and Eurovent 8/1(9) Average sound pressure level above one reflecting surface (Q=2) at 1 meter from the outside dimensions of the unit.

* secondo Eurovent

H

L

P

Page 74: Products Guide V01 - ParagonEfficient project management thanks to Climaveneta as unique project leader. Complete and specialized Organization Climaveneta qualifies itself for the

72

PRANA

BWR DHW 0011m÷0121t

Versioni

BWR DHW Geothermal reversible heat pump with domestic hot water supply with total heat recovery

FeaturesStructure and base in hot galvanised epoxy powder coatedsteel.Case panels are insulated within low noise material for furtherimprovement of silenceRubber vibration damper.Hermetic scroll type compressors, equipped with thecrankcase heater and thermal protectionStainless steel (AISI 316) with high efficiency and low pressuredrop plate to plate exchanger (at the domestic hot water side).It is positioned next after the compressor, it ensures thedomestic hot water production. That can work either in fullrecovery or in part, with the constant optimization of efficiencythrough logic advanced adjusting controllerExchangers plant side plate of stainless steel AISI 316 withhigh efficiency and low pressure drop meets the supply of bothhot or cold water for the facility, regardless of the domestic hotwaterHigh efficiency and low pressure drop stainless steel (AISI 316)source side plate exchangerSoft starter for 230V/1/50Hz units /msThe water circuit comes complete with:

• Variable flow circulator for 0011÷0031 models and multistage centrifugal variable flow pump for models 0071÷0121, plant side

• Domestic hot water, water side, variable flow pump• Variable flow circulator for 0011÷0031 models, multistage

centrifugal variable flow pump for models0071-0121 on source side (for geothermal systems, closed vertical or horizontal loops)

• Safety valve• Expansion tank• Drain valve on both plant and source circuits

Main accessories• Buffer tank 35,100,200 liters• Hot water cylinder 300,500 liters• 300 litres thermal store for domestic hot water, for kit

DOMH2O• 300,500,1000 litres thermal store for domestic hot water

with solar heat exchanger, for kit DOMH2O• DOMH2O15 e DOMH2O24 kit for domestic hot water

with external heat exchanger plate-to-plate and pump• Remote keyboard• Removable metal mesh water filter kit

Unit descriptionPRANA DHW is the heat pump new generation able to operate throughout the year inany operating mode: either a single cycle (air conditioning, heating, hot water) andcombined cycle (hot water along with air conditioning or heating). Energy efficiency ishighest during the summer cycle, when, thanks to the full recovery of the heat, theproduction of hot water is free. During the combined use, the DHW exchanger usesthe temperature of the hot exhaust gases to gets inside the accumulation sanitarywater as high as 65° C.The advanced CLIMAVENETA fully patented electronic ensures the highest flexibility ofoperation, a rapid speed and a significant increase in the overall COP, which go handin hand with electricity and space reduction. Advantages, combined with the possibilityof completely eliminating the traditional boiler, making heat pumps PRANA DHW the

ideal solution for energy saving applications in residential, hotel and small sector.

CommandsUser interface unit on board, accessible from the outside with a not touch systemBWR-DHW heats water stored in the tank as energy storage. It also comes with a state-of-the-art electronic unit,which independently controls the modes of operation. The appliance can operate throughout the year in anymode, both with single cycle (cooling, heating, hot water) and with combined cycle (hot water together withcooling or hot water together heating).During the summer cycle there is maximum energy saving through total heatrecovery. This energy is completely free of charge with regard to the production of hot water.

Reversible heat pump, total heatrecovery, geothermal source4,5 ÷ 29,7 kW

Page 75: Products Guide V01 - ParagonEfficient project management thanks to Climaveneta as unique project leader. Complete and specialized Organization Climaveneta qualifies itself for the

73

Models 0011m 0021m 0025m 0031m 0041m 0011ms 0021ms 0025ms 0031ms 0041ms

Nominal heating power (1) kW 4,50 5,70 6,70 7,80 9,70 4,50 5,70 6,70 7,80 9,70Total absorbed power (2) kW 1,30 1,60 1,90 2,30 2,80 1,30 1,60 1,90 2,30 2,80COP 3,44 3,45 3,48 3,39 3,51 3,44 3,45 3,48 3,39 3,51Cooling capacity (3) kW 7,30 9,20 11 12,5 15,3 7,30 9,20 11 12,5 15,3Total absorbed power (2) kW 1,30 1,70 2 2,40 2,90 1,30 1,70 2 2,40 2,90EER 5,62 5,41 5,50 5,21 5,28 5,62 5,41 5,50 5,21 5,28Total absorbed power (4) kW 6 7,80 9,20 10,3 12,9 6 7,80 9,20 10,3 12,9Total absorbed power kW 1,90 2,40 2,90 3,40 4,20 1,90 2,40 2,90 3,40 4,20Recovery heating capacity (4) kW 7,90 10 11,9 13,5 16,8 7,90 10 11,9 13,5 16,8Heating capacity (5) kW 4,30 5,50 6,60 7,70 9,40 4,30 5,50 6,60 7,70 9,40Total absorbed power (2) kW 1,70 2,10 2,50 3 3,50 1,70 2,10 2,50 3 3,50COP 2,60 2,63 2,64 2,59 2,69 2,60 2,63 2,64 2,59 2,69Cooling capacity (6) kW 5,10 6,50 7,70 8,90 11 5,10 6,50 7,70 8,90 11Total absorbed power (2) kW 1,30 1,70 2 2,40 2,90 1,30 1,70 2 2,40 2,90EER 3,92 3,82 3,85 3,71 3,79 3,92 3,82 3,85 3,71 3,79Compressor type SCROLLN. Compressors N. 1Refrigerant R407CPlant side pump type (7) Ci Ci Ci Ci Ci Ci Ci Ci Ci CiRecovery side pump type (7) Ci Ci Ci Ci Ci Ci Ci Ci Ci CiSource side pump type (7) Ci Ci Ci Ci Ce Ci Ci Ci Ci CeElectrical power supply V-Ph~Hz 230-1~50 230-1~50 230-1~50 230-1~50 230-1~50 230-1~50 230-1~50 230-1~50 230-1~50 230-1~50Start-up current A 47 61 76 100 114 21 27 34 45 51Sound power (8) dB(A) 52 52 53 53 58 52 52 53 53 58Sound pressure (9) dB(A) 38 38 39 39 44 38 38 39 39 44DIMENSIONL mm 560H mm 980P mm 575Operational weight kg 188 188 190 195 215 188 188 190 195 215

Models 0021t 0025t 0031t 0041t 0051t 0061t 0071t 0091t 0101t 0121t

Nominal heating power (1) kW 5,60 6,60 7,70 9,50 11,4 13,9 18,8 21,2 24,4 29,7Total absorbed power (2) kW 1,60 1,90 2,20 2,70 3,20 3,70 5,10 5,60 6,60 8,30COP 3,50 3,51 3,44 3,56 3,57 3,72 3,70 3,81 3,72 3,57Cooling capacity (3) kW 9,20 10,9 12,4 15,4 19,1 22,5 30,2 34,4 38,9 49,7Total absorbed power (2) kW 1,60 1,90 2,30 2,80 3,60 4,10 5,50 6,10 7,30 9,30EER 5,75 5,74 5,39 5,50 5,31 5,49 5,49 5,64 5,33 5,34Total absorbed power (4) kW 7,70 9,10 10,3 13,1 16 18,9 25,5 29 32,7 41,1Total absorbed power kW 2,30 2,80 3,30 4 4,90 5,70 7,70 8,40 10,2 12,8Recovery heating capacity (4) kW 9,90 11,7 13,4 16,9 20,6 24,2 32,7 36,9 42,4 53,1Heating capacity (5) kW 5,40 6,50 7,50 9,30 11,1 13,3 17,9 20,5 23,5 28,4Total absorbed power (2) kW 2 2,40 2,90 3,40 4 4,70 6,50 7 8,30 10,5COP 2,67 2,67 2,63 2,75 2,78 2,86 2,77 2,95 2,84 2,69Cooling capacity (6) kW 6,50 7,70 8,80 10,9 13,4 16,1 21,7 24,6 28 34,8Total absorbed power (2) kW 1,70 2 2,30 2,80 3,40 4 5,40 5,90 7 8,90EER 3,82 3,85 3,83 3,89 3,94 4,03 4,02 4,17 4,00 3,91Compressor type SCROLL N. Compressors N. 1Refrigerant R407CPlant side pump type (7) Ci Ci Ci Ci Ci Ci Ce Ce Ce CeRecovery side pump type (7) Ci Ci Ci Ci Ci Ci Ci Ci Ci CiSource side pump type (7) Ci Ci Ci Ce Ce Ce Ce Ce Ce CeElectrical power supply V-Ph~Hz 400-3N~50 400-3N~50 400-3N~50 400-3N~50 400-3N~50 400-3N~50 400-3N~50 400-3N~50 400-3N~50 400-3N~50Start-up current A 32 40 46 50 66 74 95 111 118 140Sound power (8) dB(A) 52 52 52 58 58 59 66 66 70 70Sound pressure (9) dB(A) 38 38 38 44 44 45 51 51 55 55DIMENSIONL mm 560 560 560 560 560 560 680 680 680 680H mm 980 980 980 980 980 980 1150 1150 1150 1150P mm 575 575 575 575 575 575 780 780 780 780Operational weight kg 188 190 195 215 228 233 260 270 280 305

BWR DHW

H

L P

NOTE(1) Condenser water in-out 30/35°C (plant side), Evaporator water in-out 0/-3°C (source side)(2) According to Eurovent(3) Evaporator water in-out 23/18°C (plant side), Condenser water in-out 30/35°C (source side)(4) Water in-out 23/18°C (plant side), water in-out 45/50°C (total recovery side)(5) Condenser water in-out 40/45°C (plant side), Evaporator water in-out 0/-3°C (source side)(6) Evaporator water in-out 12/7°C (plant side), Condenser water in-out 30/35°C (source side)(7) Ci=Circolatore; Ce=Centrifuga(8) Sound power level according to ISO 9614 and Eurovent 8/1(9) Average sound pressure level above one reflecting surface (Q=2) at 1 meter from the outside dimensions of the unit.

Page 76: Products Guide V01 - ParagonEfficient project management thanks to Climaveneta as unique project leader. Complete and specialized Organization Climaveneta qualifies itself for the

74

-DRONIC --RR

Page 77: Products Guide V01 - ParagonEfficient project management thanks to Climaveneta as unique project leader. Complete and specialized Organization Climaveneta qualifies itself for the

75

CHILLERhydronic - chiller

hyd

ron

icch

ille

r

Page 78: Products Guide V01 - ParagonEfficient project management thanks to Climaveneta as unique project leader. Complete and specialized Organization Climaveneta qualifies itself for the

76

Main accessoriesSet-up for remote connectivity with ModBus/Echelon/Bacnet protocol cards

Remote keyboard (distance to 200m and to 500m)

Soft starters

Electronic expansion valve

Rubber anti-vibration mounting kit. Spring anti-vibration mounting kit (4 compressors models only)

FeaturesREFRIGERANT GAS R410A

The use of R410A has resulted in units offering better energy efficiency in full respect for the environment (ODP = 0)

TOTAL VERSATILITY

Climaveneta is the only company to offer units with Scroll compressors in 5 versions and 3 different configurations designed to satisfy all service system and application requirementsSTANDARD SUPPLY WITH WATER FILTER ALREADY INSTALLEDThe water filter is already installed as standard supply on all units, including those without hydronic kit. This simplifies installation procedures, while ensuring maximum working reliability

INTEGRATED HYDRONIC MODULE

The incorporated hydronic unit already contains the main water circuit components; it is available in various configurations with one or two pumps with high or low head and the buffer tank

Configurations- base function

D partial condensing heat recovery function

R total condensing heat recovery function

VersionsB base version

HL low noise, high efficiency, high outdoor temperature version

HT high efficiency, high outdoor temperature version

LN low noise version

SL super-low noise version

CommandsW3000 Base / W3000SE CompactThe controller can be chosen as: - W3000 Base: keypad and LED display - W3000SE Compact: the keypad features an easy-to-use interface and a complete LCD display, allowing to consult and intervene on the unit by means of a multi-level menu, with selectable language setting. The diagnostics includes a complete alarm management, with the “black-box” and alarm logging functions for enhanced analysis of the unit operation. Compatibility with the remote keyboard managing up to 10 units. Availability of an internal real time clock for operation scheduling (4-day profiles with 10 hour belts). Common features: The regulation is based on the exclusive QuickMind algorithm, including self-adaptive control logics, beneficial in low water content systems. As alternatives the proportional- or proportional-integral regulations are also available. For multiple units systems, the regulation of the resources, via optional proprietary devices, can be implemented. Energy metering, for both consumption and capacity, can also be developed. Supervision can be easily developed via proprietary devices or the integration in third party systems by means of the most common protocols as ModBus, Bacnet, Bacnet-over-IP, Echelon LonWorks.

Hydronic - chiller

NECS 0152÷1204

Chiller, air source for outdoor installation

33,8 - 341 kWUnit DescriptionOutdoor unit for the production of chilled water with hermetic rotary Scroll compressors dedicated for the use of R410A, axial-flow fans, braze-welded plate-type exchanger and thermal expansion valve. External panels in Peraluman and structure in aluminium sections. The range includes the single-circuit two-compressor versions and the dual circuit four-compressor versions.

Page 79: Products Guide V01 - ParagonEfficient project management thanks to Climaveneta as unique project leader. Complete and specialized Organization Climaveneta qualifies itself for the

77

Note:

1 Evaporator water (in/out) = 12/7°C; Condenser air (in) = 35°C.

2 Evaporator water (in/out) = 12/7°C; Condenser air (in) = 35°C; Desuperheater water (in/out) = 40/45°C.

3 Evaporator water (in/out) = 12/7°C; Recovery unit water (in/out) = 40/45°C

4 Sound power on the basis of measurements made in compliance with ISO 9614 and Eurovent 8/1 for Eurovent certified units; in compliance with ISO 3744 for non-certified units.

5 Average sound pressure level, at 10m distance, unit in a free field on a reflective surface; non-binding value obtained from the sound power level.

6 Unit in standard configuration/execution, without optional accessories

Models 0612 0504 0524 0604 0704 0804 0904 1004 1104 1204COOLINGCooling capacity (1) kW 159 113 136 154 177 200 223 255 293 325Total power input (1) kW 58,7 45,6 53,8 59,7 67,8 74,9 84,2 94,1 106 121EER 2,71 2,48 2,53 2,58 2,61 2,67 2,65 2,71 2,76 2,68ESEER 4,20 4,10 3,60 3,79 3,91 4,08 4,15 3,96 4,10 4,16COOLING WITH PARTIAL RECOVERYCooling capacity (2) kW 165 118 141 160 183 207 232 265 304 337Total power input (2) kW 54,2 40 43,8 49,6 57,2 64,2 73,3 78,7 90,4 105Desuperheater heating capacity (2) kW 50,1 37 40,5 45,9 53 59,4 67,8 72,8 83,6 97COOLING WITH TOTAL RECOVERYCooling capacity (3) kW 118 138 158 181 204 231 258 295 333Total power input (3) kW 38,7 44,1 49,4 56,9 64,5 72,1 79,8 92,8 105Heat recovery capacity (3) kW 155 179 204 234 264 299 333 382 431COMPRESSORSNo. Compressors/No. Circuits N. 2 / 1 4 / 2 4 / 2 4 / 2 4 / 2 4 / 2 4 / 2 4 / 2 4 / 2 4 / 2NOISE LEVELSSound power (4) dB(A) 87 91 92 92 92 92 93 94 95 95Sound pressure (5) dB(A) 55 59 60 60 60 60 61 62 63 63SIZEA (6) mm 3245 3110 3110 3110 3110 3110 4110 4110 4110 4110B (6) mm 1120 2220 2220 2220 2220 2220 2220 2220 2220 2220H (6) mm 1620 1700 1700 1700 2150 2150 2150 2150 2150 2150Operating weight (6) kg 980 1230 1450 1620 1780 1890 2070 2220 2380 2530

NECS / BModels 0152 0182 0202 0252 0302 0352 0412 0452 0512 0552COOLINGCooling capacity (1) kW 38,1 45,1 50,5 57 76 86,8 96,9 112 127 145Total power input (1) kW 14,4 15,6 19,1 21,5 27,8 31,9 36,3 39,6 43,8 50,5EER 2,65 2,89 2,64 2,65 2,73 2,72 2,67 2,83 2,90 2,87ESEER 4,05 4,29 4,22 4,15 4,15 4,27 4,17 4,30 4,25 4,40COOLING WITH PARTIAL RECOVERYCooling capacity (2) kW 39,5 46,8 52,4 59,2 78,9 90,1 101 117 131 150Total power input (2) kW 12,9 14,1 17,4 19,8 25,4 29,3 33,6 36,4 39,8 46Desuperheater heating capacity (2) kW 11,9 13 16,1 18,3 23,5 27,1 31,1 33,6 36,8 42,6COOLING WITH TOTAL RECOVERYCooling capacity (3) kWTotal power input (3) kWHeat recovery capacity (3) kWCOMPRESSORSNo. Compressors/No. Circuits N. 2 / 1 2 / 1 2 / 1 2 / 1 2 / 1 2 / 1 2 / 1 2 / 1 2 / 1 2 / 1NOISE LEVELSSound power (4) dB(A) 84 84 84 84 85 86 86 86 87 87Sound pressure (5) dB(A) 52 52 52 52 53 54 54 54 55 55SIZEA (6) mm 1695 1695 1695 1695 2195 2195 2745 2745 3245 3245B (6) mm 1120 1120 1120 1120 1120 1120 1120 1120 1120 1120H (6) mm 1420 1420 1420 1420 1420 1420 1420 1420 1620 1620Operating weight (6) kg 380 410 420 430 630 660 740 800 950 970

COOLING

r HFCR-410A

SCROLLAXIALPLATES

Page 80: Products Guide V01 - ParagonEfficient project management thanks to Climaveneta as unique project leader. Complete and specialized Organization Climaveneta qualifies itself for the

78

Note:

1 Evaporator water (in/out) = 12/7°C; Condenser air (in) = 35°C.

2 Evaporator water (in/out) = 12/7°C; Condenser air (in) = 35°C; Desuperheater water (in/out) = 40/45°C.

3 Evaporator water (in/out) = 12/7°C; Recovery unit water (in/out) = 40/45°C

4 Sound power on the basis of measurements made in compliance with ISO 9614 and Eurovent 8/1 for Eurovent certified units; in compliance with ISO 3744 for non-certified units.

5 Average sound pressure level, at 10m distance, unit in a free field on a reflective surface; non-binding value obtained from the sound power level.

6 Unit in standard configuration/execution, without optional accessories

NECS / HLModels 0504 0524 0604 0704 0804 0904 1004 1104 1204COOLINGCooling capacity (1) kW 118 136 151 172 201 222 249 290 326Total power input (1) kW 43,7 49,8 58,1 66,7 72,8 83,8 91,9 102 117EER 2,70 2,73 2,60 2,58 2,76 2,65 2,71 2,83 2,77ESEER 3,93 4,04 4,02 4,15 4,02 4,04 4,14 4,37 4,16COOLING WITH PARTIAL RECOVERYCooling capacity (2) kW 123 141 157 178 209 231 258 301 338Total power input (2) kW 42,4 48,4 56,2 64,4 70,7 81,1 88,8 99,1 104Desuperheater heating capacity (2) kW 34,8 40,4 47,5 55,1 58,7 68,3 75,5 85,1 96,5COOLING WITH TOTAL RECOVERYCooling capacity (3) kW 118 138 158 181 204 231 258 295 333Total power input (3) kW 38,7 44,1 49,4 56,9 64,5 72,1 79,8 92,8 105Heat recovery capacity (3) kW 155 179 204 234 264 299 333 382 431COMPRESSORSNo. Compressors/No. Circuits N. 4 / 2 4 / 2 4 / 2 4 / 2 4 / 2 4 / 2 4 / 2 4 / 2 4 / 2NOISE LEVELSSound power (4) dB(A) 86 86 86 86 88 88 88 90 91Sound pressure (5) dB(A) 54 54 54 54 56 56 56 58 59SIZEA (6) mm 3110 3110 3110 3110 4110 4110 4110 5110 5110B (6) mm 2220 2220 2220 2220 2220 2220 2220 2220 2220H (6) mm 1700 2150 2150 2150 2150 2150 2150 2150 2150Operating weight (6) kg 1360 1570 1710 1860 2120 2180 2320 2630 2770

Page 81: Products Guide V01 - ParagonEfficient project management thanks to Climaveneta as unique project leader. Complete and specialized Organization Climaveneta qualifies itself for the

79

Note:

1 Evaporator water (in/out) = 12/7°C; Condenser air (in) = 35°C.

2 Evaporator water (in/out) = 12/7°C; Condenser air (in) = 35°C; Desuperheater water (in/out) = 40/45°C.

3 Evaporator water (in/out) = 12/7°C; Recovery unit water (in/out) = 40/45°C

4 Sound power on the basis of measurements made in compliance with ISO 9614 and Eurovent 8/1 for Eurovent certified units; in compliance with ISO 3744 for non-certified units.

5 Average sound pressure level, at 10m distance, unit in a free field on a reflective surface; non-binding value obtained from the sound power level.

6 Unit in standard configuration/execution, without optional accessories

Models 0504 0524 0604 0704 0804 0904 1004 1104 1204COOLINGCooling capacity (1) kW 123 142 159 182 210 233 262 303 341Total power input (1) kW 45,4 50,5 57,8 65 74,5 84,1 90,7 101 117EER 2,71 2,81 2,75 2,80 2,82 2,77 2,89 2,99 2,91ESEER 3,63 3,76 3,90 4,02 3,82 3,86 4,08 4,25 4,08COOLING WITH PARTIAL RECOVERYCooling capacity (2) kW 127 147 165 189 218 242 272 315 354Total power input (2) kW 44 49,2 55,9 63 72,2 81,5 88,1 98,4 114Desuperheater heating capacity (2) kW 32,9 37,7 43,9 50,5 55,1 63,8 69,8 85,8 97,1COOLING WITH TOTAL RECOVERYCooling capacity (3) kW 118 138 158 181 204 231 258 295 333Total power input (3) kW 38,7 44,1 49,4 56,9 64,5 72,1 79,8 92,8 105Heat recovery capacity (3) kW 155 179 204 234 264 299 333 382 431COMPRESSORSNo. Compressors/No. Circuits N. 4 / 2 4 / 2 4 / 2 4 / 2 4 / 2 4 / 2 4 / 2 4 / 2 4 / 2NOISE LEVELSSound power (4) dB(A) 92 92 92 92 94 94 94 96 97Sound pressure (5) dB(A) 60 60 60 60 62 62 62 64 65SIZEA (6) mm 3110 3110 3110 3110 4110 4110 4110 5110 5110B (6) mm 2220 2220 2220 2220 2220 2220 2220 2220 2220H (6) mm 1700 2150 2150 2150 2150 2150 2150 2150 2150Operating weight (6) kg 1360 1570 1710 1860 2120 2180 2320 2630 2770

NECS / HTModels 0152 0182 0202 0252 0302 0352 0412 0452 0512COOLINGCooling capacity (1) kW 39,7 46,7 55 61,6 80,6 91,4 104 116 130Total power input (1) kW 13,5 15,2 17,3 20,3 25,9 30,5 33,7 38,7 42,2EER 2,94 3,07 3,18 3,03 3,11 3 3,09 3 3,08ESEER 4,28 4,18 4,41 4,09 4,27 4,18 4,28 4,31 4,39COOLING WITH PARTIAL RECOVERYCooling capacity (2) kW 41,2 48,5 57 63,9 83,6 94,9 108 120 135Total power input (2) kW 12,1 13,3 15,3 17,7 23,1 27,1 30,1 34,8 38,3Desuperheater heating capacity (2) kW 11,2 12,3 14,1 16,3 21,3 25 27,8 32,2 35,5COOLING WITH TOTAL RECOVERYCooling capacity (3) kWTotal power input (3) kWHeat recovery capacity (3) kWCOMPRESSORSNo. Compressors/No. Circuits N. 2 / 1 2 / 1 2 / 1 2 / 1 2 / 1 2 / 1 2 / 1 2 / 1 2 / 1NOISE LEVELSSound power (4) dB(A) 84 85 85 86 86 87 87 87 87Sound pressure (5) dB(A) 52 53 53 54 54 55 55 55 55SIZEA (6) mm 1695 2195 2195 2745 2745 3245 3245 3245 3245B (6) mm 1120 1120 1120 1120 1120 1120 1120 1120 1120H (6) mm 1420 1420 1420 1420 1420 1620 1620 1620 1620Operating weight (6) kg 400 460 490 550 710 800 880 930 960

Page 82: Products Guide V01 - ParagonEfficient project management thanks to Climaveneta as unique project leader. Complete and specialized Organization Climaveneta qualifies itself for the

80

Note:

1 Evaporator water (in/out) = 12/7°C; Condenser air (in) = 35°C.

2 Evaporator water (in/out) = 12/7°C; Condenser air (in) = 35°C; Desuperheater water (in/out) = 40/45°C.

3 Evaporator water (in/out) = 12/7°C; Recovery unit water (in/out) = 40/45°C

4 Sound power on the basis of measurements made in compliance with ISO 9614 and Eurovent 8/1 for Eurovent certified units; in compliance with ISO 3744 for non-certified units.

5 Average sound pressure level, at 10m distance, unit in a free field on a reflective surface; non-binding value obtained from the sound power level.

6 Unit in standard configuration/execution, without optional accessories

Models 0612 0504 0524 0604 0704 0804 0904 1004 1104 1204COOLINGCooling capacity (1) kW 151 104 129 147 167 187 208 242 275 306Total power input (1) kW 62,4 47,9 53,5 60 69,6 77,6 87,8 95,3 109 125EER 2,42 2,17 2,41 2,45 2,40 2,41 2,37 2,54 2,52 2,44ESEER 3,96 3,93 3,84 3,91 4,01 3,99 4,07 4,01 4,15 4,06COOLING WITH PARTIAL RECOVERYCooling capacity (2) kW 157 108 134 153 173 194 216 251 286 317Total power input (2) kW 57,8 46,6 51,8 58,2 67,1 75,3 85,2 92 106 121Desuperheater heating capacity (2) kW 53,5 40,9 43,5 49,3 57,6 65,2 74,4 78,4 91,3 105COOLING WITH TOTAL RECOVERYCooling capacity (3) kW 118 138 158 181 204 231 258 295 333Total power input (3) kW 38,7 44,1 49,4 56,9 64,5 72,1 79,8 92,8 105Heat recovery capacity (3) kW 155 179 204 234 264 299 333 382 431COMPRESSORSNo. Compressors/No. Circuits N. 2 / 1 4 / 2 4 / 2 4 / 2 4 / 2 4 / 2 4 / 2 4 / 2 4 / 2 4 / 2NOISE LEVELSSound power (4) dB(A) 84 85 86 86 86 86 87 88 89 89Sound pressure (5) dB(A) 52 53 54 54 54 54 55 56 57 57SIZEA (6) mm 3245 3110 3110 3110 3110 3110 4110 4110 4110 4110B (6) mm 1120 2220 2220 2220 2220 2220 2220 2220 2220 2220H (6) mm 1620 1700 1700 1700 2150 2150 2150 2150 2150 2150Operating weight (6) kg 980 1230 1450 1620 1780 1890 2070 2220 2380 2530

NECS / LNModels 0152 0182 0202 0252 0302 0352 0412 0452 0512 0552COOLINGCooling capacity (1) kW 36,1 42,8 50,7 57,6 74,2 84,4 96,4 109 122 139Total power input (1) kW 15 16,4 19 21,3 28,7 33,8 37,1 41,4 45,9 53,3EER 2,41 2,61 2,67 2,70 2,59 2,50 2,60 2,63 2,66 2,61ESEER 4,03 4,20 4,25 4,22 4,11 3,99 4,02 4,15 4,06 4,19COOLING WITH PARTIAL RECOVERYCooling capacity (2) kW 37,5 44,4 52,6 59,8 77 87,6 100 113 127 144Total power input (2) kW 13,9 15,3 17,3 19,6 26,4 30,5 33,8 38 41,9 48,8Desuperheater heating capacity (2) kW 12,9 14,1 16 18,1 24,4 28,3 31,3 35,2 38,7 45,2COOLING WITH TOTAL RECOVERYCooling capacity (3) kWTotal power input (3) kWHeat recovery capacity (3) kWCOMPRESSORSNo. Compressors/No. Circuits N. 2 / 1 2 / 1 2 / 1 2 / 1 2 / 1 2 / 1 2 / 1 2 / 1 2 / 1 2 / 1NOISE LEVELSSound power (4) dB(A) 79 79 80 80 81 83 83 83 84 84Sound pressure (5) dB(A) 47 47 48 48 49 51 51 51 52 52SIZEA (6) mm 1695 1695 2195 2195 2745 2745 2745 2745 3245 3245B (6) mm 1120 1120 1120 1120 1120 1120 1120 1120 1120 1120H (6) mm 1420 1420 1420 1420 1420 1620 1620 1620 1620 1620Operating weight (6) kg 380 410 470 510 680 730 800 840 950 970

Page 83: Products Guide V01 - ParagonEfficient project management thanks to Climaveneta as unique project leader. Complete and specialized Organization Climaveneta qualifies itself for the

81

Minimum clearance required0152-0512 0504-1204

Switchboard side mm 600 1100Switchboard opposite side mm 600 1100Condensation coil side mm 1000 2000

Note:

1 Evaporator water (in/out) = 12/7°C; Condenser air (in) = 35°C.

2 Evaporator water (in/out) = 12/7°C; Condenser air (in) = 35°C; Desuperheater water (in/out) = 40/45°C.

3 Evaporator water (in/out) = 12/7°C; Recovery unit water (in/out) = 40/45°C

4 Sound power on the basis of measurements made in compliance with ISO 9614 and Eurovent 8/1 for Eurovent certified units; in compliance with ISO 3744 for non-certified units.

5 Average sound pressure level, at 10m distance, unit in a free field on a reflective surface; non-binding value obtained from the sound power level.

6 Unit in standard configuration/execution, without optional accessories

Models 0504 0524 0604 0704 0804 0904 1004 1104 1204COOLINGCooling capacity (1) kW 113 130 147 161 193 211 235 278 313Total power input (1) kW 45,2 51,8 58,8 70,6 75,4 87,2 96,7 106 121EER 2,50 2,51 2,50 2,28 2,56 2,42 2,43 2,61 2,58ESEER 4,02 4,14 4,14 4,13 4,08 4,08 4,10 4,39 4,19COOLING WITH PARTIAL RECOVERYCooling capacity (2) kW 117 135 152 167 200 219 243 288 325Total power input (2) kW 43,7 50,2 56,9 68,4 72,8 84,3 93,2 103 117Desuperheater heating capacity (2) kW 37,2 43,2 49,5 60,1 62,6 73,2 81,5 90,2 102COOLING WITH TOTAL RECOVERYCooling capacity (3) kW 118 138 158 181 204 231 258 295 325Total power input (3) kW 38,7 44,1 49,4 56,9 64,5 72,1 79,8 92,8 105Heat recovery capacity (3) kW 155 179 204 234 264 298 333 382 431COMPRESSORSNo. Compressors/No. Circuits N. 4 / 2 4 / 2 4 / 2 4 / 2 4 / 2 4 / 2 4 / 2 4 / 2 4 / 2NOISE LEVELSSound power (4) dB(A) 82 82 82 82 83 83 83 85 86Sound pressure (5) dB(A) 50 50 50 50 51 51 51 53 54SIZEA (6) mm 3110 3110 3110 3110 4110 4110 4110 5110 5110B (6) mm 2220 2220 2220 2220 2220 2220 2220 2220 2220H (6) mm 1700 2150 2150 2150 2150 2150 2150 2150 2150Operating weight (6) kg 1360 1570 1770 1860 2120 2180 2320 2630 2770

NECS / SLModels 0152 0182 0202 0252 0302 0352 0412 0452 0512COOLINGCooling capacity (1) kW 33,8 42,3 47,8 55,5 69,9 85,4 96,8 106 118Total power input (1) kW 16,3 17,1 20,4 22,6 30,9 33,6 37,2 43,1 48,4EER 2,07 2,47 2,34 2,46 2,26 2,54 2,60 2,46 2,44ESEER 3,77 3,93 4,01 3,89 3,86 3,87 3,91 3,91 3,90COOLING WITH PARTIAL RECOVERYCooling capacity (2) kW 35 43,9 49,6 57,5 72,6 88,6 101 110 122Total power input (2) kW 15,1 15,5 18,7 20,6 28,6 30 33,6 39,3 44Desuperheater heating capacity (2) kW 14 14,3 17,3 19 26,4 27,8 31,1 36,3 40,7COOLING WITH TOTAL RECOVERYCooling capacity (3) kWTotal power input (3) kWHeat recovery capacity (3) kWCOMPRESSORSNo. Compressors/No. Circuits N. 2 / 1 2 / 1 2 / 1 2 / 1 2 / 1 2 / 1 2 / 1 2 / 1 2 / 1NOISE LEVELSSound power (4) dB(A) 76 77 77 78 78 81 81 81 82Sound pressure (5) dB(A) 44 45 45 46 46 49 49 49 50SIZEA (6) mm 1695 2195 2195 2745 2745 3245 3245 3245 3245B (6) mm 1120 1120 1120 1120 1120 1120 1120 1120 1120H (6) mm 1420 1420 1420 1420 1420 1620 1620 1620 1620Operating weight (6) kg 400 460 490 550 710 800 880 930 960

A

B

H

AB

H

Page 84: Products Guide V01 - ParagonEfficient project management thanks to Climaveneta as unique project leader. Complete and specialized Organization Climaveneta qualifies itself for the

82

Main accessoriesSet-up for remote connectivity with ModBus/Echelon/Bacnet protocol cards

Remote keyboard (distance to 200m and to 500m)

LCD display keyboard type W3000Compact with multi-language user interface (refers to the shown picture)

Soft starters

Rubber anti-vibration mounting kit

FeaturesREFRIGERANT GAS R410A

The use of R410A has resulted in units offering better energy efficiency in full respect for the environment (ODP = 0)

SHELL AND TUBES EXCHANGER

The shell and tube exchanger allows to achieve the highest flexibility on the units installation, keeping the efficiency at the maximum level. For this reason, NECS represents the best choice for all the hydronic application on the residential, commercial and industrial markets.

INTEGRATED HYDRONIC MODULE

The built-in hydronic module already contains the main water circuit components; it is available with single or twin in-line, for achieving both low or high head.

MAXIMUM RELIABILITY

Unit with dual-circuit refrigerant section designed to ensure maximum efficiency at full load, ensuring continuity without interruption of operation in the event of temporary stop of one of the 2 circuits.

VersionsB base version

HT high efficiency, high outdoor temperature version

LN low noise version

SL super-low noise version

CommandsW3000 Base / W3000SE CompactThe controller can be chosen as: - W3000 Base: keypad and LED display - W3000SE Compact: the keypad features an easy-to-use interface and a complete LCD display, allowing to consult and intervene on the unit by means of a multi-level menu, with selectable language setting. The diagnostics includes a complete alarm management, with the “black-box” and alarm logging functions for enhanced analysis of the unit operation. Compatibility with the remote keyboard managing up to 10 units. Availability of an internal real time clock for operation scheduling (4-day profiles with 10 hour belts). Common features: The regulation is based on the exclusive QuickMind algorithm, including self-adaptive control logics, beneficial in low water content systems. As alternatives the proportional- or proportional-integral regulations are also available. For multiple units systems, the regulation of the resources, via optional proprietary devices, can be implemented. Energy metering, for both consumption and capacity, can also be developed. Supervision can be easily developed via proprietary devices or the integration in third party systems by means of the most common protocols as ModBus, Bacnet, Bacnet-over-IP, Echelon LonWorks. The defrost adopts a proprietary self-adaptive logic, which features the monitoring of numerous operational parameters. This allows to reduce the number and duration of the defrost cycles, with a benefit for the overall energy efficiency.

Hydronic - chiller

NECS 0202T÷0612T

Chiller, air source for outdoor installation

53,0 - 159 kWUnit DescriptionOutdoor unit for the production of chilled water with hermetic rotary Scroll compressors, axial-flow fans, shell and tubes exchanger and thermostatic expansion valve. External panels in Peraluman and structure in aluminium sections. The range is equipped with two compressors on two independent refrigerant circuits.

Page 85: Products Guide V01 - ParagonEfficient project management thanks to Climaveneta as unique project leader. Complete and specialized Organization Climaveneta qualifies itself for the

83

Note:

1 Evaporator water (in/out) = 12/7°C; Condenser air (in) = 35°C.

2 Sound power on the basis of measurements made in compliance with ISO 9614 and Eurovent 8/1 for Eurovent certified units; in compliance with ISO 3744 for non-certified units.

3 Average sound pressure level, at 10m distance, unit in a free field on a reflective surface; non-binding value obtained from the sound power level.

4 Unit in standard configuration/execution, without optional accessories

NECS / LNModels 0202T 0252T 0302T 0352T 0412T 0452T 0512T 0552T 0612TCOOLINGCooling capacity (1) kW 50,7 57,6 74,2 84,4 96,4 109 122 0 0Total power input (1) kW 18,9 21,2 28,6 33,7 37,1 41,4 45,9 53,1 62,4EER 2,68 2,72 2,59 2,50 2,60 2,63 2,66 0 0ESEER 3,50 3,51 3,37 3,22 3,33 3,36 3,38 3,34 3,11COMPRESSORSNo. Compressors/No. Circuits N. 02 / 02 02 / 02 02 / 02 02 / 02 02 / 02 02 / 02 02 / 02 02 / 02 02 / 02NOISE LEVELSSound power (2) dB(A) 80 80 81 83 83 83 84 84 84Sound pressure (3) dB(A) 48 48 49 51 51 51 52 52 52SIZEA (4) mm 2195 2195 2745 2745 2745 2745 3245 3245 3245B (4) mm 1120 1120 1120 1120 1120 1120 1120 1120 1120H (4) mm 1420 1420 1420 1620 1620 1620 1620 1620 1620Operating weight (4) kg 625 650 715 840 965 1025 1135 1180 1155

Note:

1 Evaporator water (in/out) = 12/7°C; Condenser air (in) = 35°C.

2 Sound power on the basis of measurements made in compliance with ISO 9614 and Eurovent 8/1 for Eurovent certified units; in compliance with ISO 3744 for non-certified units.

3 Average sound pressure level, at 10m distance, unit in a free field on a reflective surface; non-binding value obtained from the sound power level.

4 Unit in standard configuration/execution, without optional accessories

NECS / HTModels 0202T 0252T 0302T 0352T 0412T 0452T 0512TCOOLINGCooling capacity (1) kW 55 61,6 80,6 91,4 104 116 130Total power input (1) kW 17,3 20,3 25,9 30,5 33,7 38,6 42,2EER 3,18 3,03 3,11 3 3,09 3 3,08ESEER 4,07 3,91 3,93 3,76 3,87 3,76 3,86COMPRESSORSNo. Compressors/No. Circuits N. 02 / 02 02 / 02 02 / 02 02 / 02 02 / 02 02 / 02 02 / 02NOISE LEVELSSound power (2) dB(A) 85 86 86 87 87 87 87Sound pressure (3) dB(A) 53 54 54 55 55 55 55SIZEA (4) mm 2195 2745 2745 3245 3245 3245 3245B (4) mm 1120 1120 1120 1120 1120 1120 1120H (4) mm 1420 1420 1420 1620 1620 1620 1620Operating weight (4) kg 650 700 750 915 1050 1075 1115

Note:

1 Evaporator water (in/out) = 12/7°C; Condenser air (in) = 35°C.

2 Sound power on the basis of measurements made in compliance with ISO 9614 and Eurovent 8/1 for Eurovent certified units; in compliance with ISO 3744 for non-certified units.

3 Average sound pressure level, at 10m distance, unit in a free field on a reflective surface; non-binding value obtained from the sound power level.

4 Unit in standard configuration/execution, without optional accessories

NECS / BModels 0202T 0252T 0302T 0352T 0412T 0452T 0512T 0552T 0612TCOOLINGCooling capacity (1) kW 53 58,1 76,0 86,8 96,9 112 127 145 159Total power input (1) kW 18,3 21,5 27,8 31,9 36,3 39,7 43,7 50,2 58,6EER 2,90 2,70 2,73 2,72 2,67 2,67 2,90 2,89 2,71ESEER 3,72 3,47 3,52 3,49 3,41 3,59 3,65 3,66 3,44COMPRESSORSNo. Compressors/No. Circuits N. 02 / 02 02 / 02 02 / 02 02 / 02 02 / 02 02 / 02 02 / 02 02 / 02 02 / 02NOISE LEVELSSound power (2) dB(A) 85 85 85 86 86 86 87 87 87Sound pressure (3) dB(A) 53 53 53 54 54 54 55 55 55SIZEA (4) mm 1695 1695 2195 2195 2745 2745 3245 3245 3245B (4) mm 1120 1120 1120 1120 1120 1120 1120 1120 1120H (4) mm 1420 1420 1420 1420 1420 1420 1620 1620 1620Operating weight (4) kg 625 625 665 765 920 990 1135 1180 1155

COOLINGSCROLLAXIALSHELL & TUBES

Page 86: Products Guide V01 - ParagonEfficient project management thanks to Climaveneta as unique project leader. Complete and specialized Organization Climaveneta qualifies itself for the

84

Minimum clearance required0202T-0512T

Switchboard side mm 600Switchboard opposite side mm 600Condensation coil side mm 1000

Note:

1 Evaporator water (in/out) = 12/7°C; Condenser air (in) = 35°C.

2 Sound power on the basis of measurements made in compliance with ISO 9614 and Eurovent 8/1 for Eurovent certified units; in compliance with ISO 3744 for non-certified units.

3 Average sound pressure level, at 10m distance, unit in a free field on a reflective surface; non-binding value obtained from the sound power level.

4 Unit in standard configuration/execution, without optional accessories

NECS / SLModels 0202T 0252T 0302T 0352T 0412T 0452T 0512TCOOLINGCooling capacity (1) kW 47,8 55,5 69,9 85,4 96,8 106 118Total power input (1) kW 20,3 22,6 30,9 33,6 37,3 43,2 48,1EER 2,35 2,46 2,26 2,54 2,60 2,46 2,44ESEERCOMPRESSORSNo. Compressors/No. Circuits N. 02 / 02 02 / 02 02 / 02 02 / 02 02 / 02 02 / 02 02 / 02NOISE LEVELSSound power (2) dB(A) 77 78 78 81 81 81 82Sound pressure (3) dB(A) 45 46 46 49 49 49 50SIZEA (4) mm 2195 2745 2745 3245 3245 3245 3245B (4) mm 1120 1120 1120 1120 1120 1120 1120H (4) mm 1420 1420 1420 1620 1620 1620 1620Operating weight (4) kg 650 700 750 915 1050 1075 1115

A

B

H

Page 87: Products Guide V01 - ParagonEfficient project management thanks to Climaveneta as unique project leader. Complete and specialized Organization Climaveneta qualifies itself for the

85

Page 88: Products Guide V01 - ParagonEfficient project management thanks to Climaveneta as unique project leader. Complete and specialized Organization Climaveneta qualifies itself for the

86

Main accessoriesSet-up for remote connectivity with ModBus/Echelon/Bacnet protocol cards

Remote keyboard (distance to 200m and to 500m)

Soft starters

FeaturesREFRIGERANT GAS R410A

The use of R410A has resulted in units offering better energy efficiency in full respect for the environment (ODP = 0)

ALUMINIUM MICRO-CHANNEL HEAT EXCHANGERS

The new NECS uses aluminium micro-channel condensers that ensure a premium level of efficiency. This solution also allows to reduce the refrigerant charge with respect to traditional copper/aluminium coils as well as improving the resistance against corrosion in saline or corrosive atmospheres.

SHELL AND TUBES EXCHANGER

The shell and tube exchanger allows to achieve the highest flexibility on the units installation, keeping the efficiency at the maximum level. For this reason, NECS represents the best choice for all the hydronic application on the residential, commercial and industrial markets.ELECTRONIC EXPANSION VALVE SUPPLIED STANDARDThe use of the electronic expansion valve generates considerable benefits, especially in cases of variable demand and different external conditions. It was introduced into these units as a result of accurate design choices concerning the cooling circuit and the optimisation of operation in various different working conditions

CLASS A EFFICIENCY

The full range is also available with the Class A efficiency rating. NECS/CA guaranties premium levels of efficiency thanks to the generous sizing of the refrigerant-exchange surface areas and to an accurate control of the fans.

INTEGRATED HYDRONIC MODULE

The incorporated hydronic unit already contains the main water circuit components; it is available in various configurations with one or two pumps with high or low head and the buffer tank

VersionsB base version

SL super-low noise version

CA Class A of efficiency

SL-CA Super Low noise version, Class A of efficiency

CommandsW3000SE CompactThe W3000SE Compact controller offers advanced functions and algorithms. The keypad features an easy-to-use interface and a complete LCD display, allowing to consult and intervene on the unit by means of a multi-level menu, with selectable language setting. The regulation is based on the exclusive QuickMind algorithm, including self-adaptive control logics, beneficial in low water content systems. As alternatives the proportional- or proportional-integral regulations are also available. The diagnostics includes a complete alarm management, with the “black-box” and alarm logging functions for enhanced analysis of the unit operation. For multiple units systems, the regulation of the resources, via optional proprietary devices, can be implemented. Energy metering, for both consumption and capacity, can also be developed. Supervision can be easily developed via proprietary devices or the integration in third party systems by means of the most common protocols as ModBus, Bacnet, Bacnet-over-IP, Echelon LonWorks. Compatibility with the remote keyboard managing up to 10 units. Availability of an internal real time clock for operation scheduling (4-day profiles with 10 hour belts). The defrost adopts a proprietary self-adaptive logic, which features the monitoring of numerous operational parameters. This allows to reduce the number and duration of the defrost cycles, with a benefit for the overall energy efficiency.

Hydronic - chiller

NECS 1314÷3218

Chiller, air source for outdoor installation

354 - 885 kWUnit DescriptionOutdoor unit for the production of chilled water with hermetic rotary Scroll compressors, ozone-friendly refrigerant R410A, axial-flow fans, shell and tubes exchanger and electronic expansion valve. The range is composed by units equipped with four, six and eight compressors in multi-circuit configuration.

Configurazioni- funzione base

D partial condensing heat recovery function

R total condensing heat recovery function

Page 89: Products Guide V01 - ParagonEfficient project management thanks to Climaveneta as unique project leader. Complete and specialized Organization Climaveneta qualifies itself for the

87

Note:

1 Evaporator water (in/out) = 12/7°C; Condenser air (in) = 35°C.

2 Sound power on the basis of measurements made in compliance with ISO 9614 and Eurovent 8/1 for Eurovent certified units; in compliance with ISO 3744 for non-certified units.

3 Average sound pressure level, at 10m distance, unit in a free field on a reflective surface; non-binding value obtained from the sound power level.

4 Unit in standard configuration/execution, without optional accessories

Models 2316 2416 2418 2618 2818 3018 3218COOLINGCooling capacity (1) kW 604 635 665 708 759 794 827Total power input (1) kW 214 219 234 249 261 279 296EER 2,82 2,90 2,85 2,85 2,92 2,84 2,80ESEER * * * * * * *COMPRESSORSNo. Compressors/No. Circuits N. 6 / 3 6 / 2 8 / 4 8 / 4 8 / 4 8 / 4 8 / 4NOISE LEVELSSound power (2) dB(A) 97 98 98 98 99 99 99Sound pressure (3) dB(A) 65 66 65 65 66 66 66SIZEA (4) mm 6255 6255 7430 7430 7430 7430 7430B (4) mm 2260 2260 2260 2260 2260 2260 2260H (4) mm 2450 2450 2450 2450 2450 2450 2450Operating weight (4) kg * * * * * * *

NECS / BModels 1314 1414 1614 1715 2015 1816 2116COOLINGCooling capacity (1) kW 354 379 413 458 526 501 569Total power input (1) kW 124 130 148 160 184 172 195EER 2,85 2,91 2,80 2,86 2,86 2,92 2,91ESEER * * * * * * *COMPRESSORSNo. Compressors/No. Circuits N. 4 / 2 4 / 2 4 / 2 5 / 2 5 / 2 6 / 2 6 / 2NOISE LEVELSSound power (2) dB(A) 96 96 96 96 97 97 97Sound pressure (3) dB(A) 64 64 64 64 65 65 65SIZEA (4) mm 3905 3905 3905 5080 5080 5080 6255B (4) mm 2260 2260 2260 2260 2260 2260 2260H (4) mm 2450 2450 2450 2450 2450 2450 2450Operating weight (4) kg * * * * * * *

COOLINGSCROLLAXIALSHELL & TUBESENERGY CLASS

Note:

1 Evaporator water (in/out) = 12/7°C; Condenser air (in) = 35°C.

2 Sound power on the basis of measurements made in compliance with ISO 9614 and Eurovent 8/1 for Eurovent certified units; in compliance with ISO 3744 for non-certified units.

3 Average sound pressure level, at 10m distance, unit in a free field on a reflective surface; non-binding value obtained from the sound power level.

4 Unit in standard configuration/execution, without optional accessories

Models 2316 2416 2418 2618 2818 3018 3218COOLINGCooling capacity (1) kW 579 596 616 666 718 758 795Total power input (1) kW 220 230 245 258 275 288 306EER 2,63 2,59 2,52 2,58 2,61 2,63 2,60ESEER * * * * * * *COMPRESSORSNo. Compressors/No. Circuits N. 6 / 3 6 / 2 8 / 4 8 / 4 8 / 4 8 / 4 8 / 4NOISE LEVELSSound power (2) dB(A) 91 91 91 91 92 92 92Sound pressure (3) dB(A) 58 58 58 58 59 59 59SIZEA (4) mm 7430 7430 7430 8605 9780 9780 9780B (4) mm 2260 2260 2260 2260 2260 2260 2260H (4) mm 2450 2450 2450 2450 2450 2450 2450Operating weight (4) kg * * * * * * *

NECS / SLModels 1314 1414 1614 1715 2015 1816 2116COOLINGCooling capacity (1) kW 334 358 397 432 498 465 532Total power input (1) kW 129 137 153 168 192 183 206EER 2,58 2,61 2,60 2,57 2,60 2,55 2,58ESEER * * * * * * *COMPRESSORSNo. Compressors/No. Circuits N. 4 / 2 4 / 2 4 / 2 5 / 2 5 / 2 6 / 2 6 / 2NOISE LEVELSSound power (2) dB(A) 88 88 88 88 90 89 90Sound pressure (3) dB(A) 56 56 56 56 58 57 57SIZEA (4) mm 5080 5080 5080 6255 6255 6255 7430B (4) mm 2260 2260 2260 2260 2260 2260 2260H (4) mm 2450 2450 2450 2450 2450 2450 2450Operating weight (4) kg * * * * * * *

Page 90: Products Guide V01 - ParagonEfficient project management thanks to Climaveneta as unique project leader. Complete and specialized Organization Climaveneta qualifies itself for the

88

Minimum clearance required1314-3218

Switchboard side mm 1500Switchboard opposite side mm 1500Plant exchagers opposite side mm 1500Plant exchagers side mm 2000

Note:

1 Evaporator water (in/out) = 12/7°C; Condenser air (in) = 35°C.

2 Sound power on the basis of measurements made in compliance with ISO 9614 and Eurovent 8/1 for Eurovent certified units; in compliance with ISO 3744 for non-certified units.

3 Average sound pressure level, at 10m distance, unit in a free field on a reflective surface; non-binding value obtained from the sound power level.

4 Unit in standard configuration/execution, without optional accessories

Models 2316 2416 2418 2618 2818 3018 3218COOLINGCooling capacity (1) kW 633 657 702 740 785 831 885Total power input (1) kW 204 212 225 239 250 267 283EER 3,10 3,10 3,11 3,10 3,13 3,12 3,13ESEER * * * * * * *COMPRESSORSNo. Compressors/No. Circuits N. 6 / 3 6 / 2 8 / 4 8 / 4 8 / 4 8 / 4 8 / 4NOISE LEVELSSound power (2) dB(A) 99 99 99 99 100 100 100Sound pressure (3) dB(A) 66 66 66 66 67 67 67SIZEA (4) mm 7430 7430 9780 9780 9780 9780 9780B (4) mm 2260 2260 2260 2260 2260 2260 2260H (4) mm 2450 2450 2450 2450 2450 2450 2450Operating weight (4) kg * * * * * * *

NECS / CAModels 1314 1414 1614 1715 2015 1816 2116COOLINGCooling capacity (1) kW 370 391 438 481 549 518 591Total power input (1) kW 120 125 142 154 177 166 189EER 3,10 3,13 3,10 3,12 3,10 3,11 3,12ESEER * * * * * * *COMPRESSORSNo. Compressors/No. Circuits N. 4 / 2 4 / 2 4 / 2 5 / 2 5 / 2 6 / 2 6 / 2NOISE LEVELS

Sound power (2) dB(A) 97 97 97 97 98 98 98

Sound pressure (3) dB(A) 65 65 65 65 66 66 65SIZEA (4) mm 5080 5080 5080 6255 6255 6255 7430B (4) mm 2260 2260 2260 2260 2260 2260 2260H (4) mm 2450 2450 2450 2450 2450 2450 2450Operating weight (4) kg * * * * * * *

Page 91: Products Guide V01 - ParagonEfficient project management thanks to Climaveneta as unique project leader. Complete and specialized Organization Climaveneta qualifies itself for the

89

NECS / SL-CAModels 1314 1414 1614 1715 2015 1816 2116 2316 2416 2418COOLINGCooling capacity (1) kW 371 394 440 481 550 522 592 638 663 695Total power input (1) kW 119 126 142 154 177 167 189 204 213 223EER 3,11 3,12 3,11 3,12 3,11 3,12 3,13 3,12 3,11 3,12ESEER 4,57 4,56 4,44 4,54 4,52 4,58 4,60 4,59 4,53 4,58COMPRESSORSNo. Compressors/No. Circuits N. 4 / 2 4 / 2 4 / 2 5 / 2 5 / 2 6 / 2 6 / 2 6 / 3 6 / 2 8 / 4NOISE LEVELSSound power (2) dB(A) 86 86 86 87 87 87 87 88 88 88Sound pressure (3) dB(A) 53 53 53 54 54 54 54 55 55 55SIZEA (4) mm 6255 6255 6255 7430 7430 7430 8605 8605 8605 9780B (4) mm 2260 2260 2260 2260 2260 2260 2260 2260 2260 2260H (4) mm 2450 2450 2450 2450 2450 2450 2450 2450 2450 2450Operating weight (4) kg 3490 3700 3730 4400 4510 4650 4990 5360 5360 6100

Minimum clearance required1314-2418

Switchboard side mm 1500Switchboard opposite side mm 1500Plant exchagers opposite side mm 1500Plant exchagers side mm 2000

Note:

1 Evaporator water (in/out) = 12/7°C; Condenser air (in) = 35°C.

2 Sound power on the basis of measurements made in compliance with ISO 9614 and Eurovent 8/1 for Eurovent certified units; in compliance with ISO 3744 for non-certified units.

3 Average sound pressure level, at 10m distance, unit in a free field on a reflective surface; non-binding value obtained from the sound power level.

4 Unit in standard configuration/execution, without optional accessories

AB

H

Page 92: Products Guide V01 - ParagonEfficient project management thanks to Climaveneta as unique project leader. Complete and specialized Organization Climaveneta qualifies itself for the

90

Main accessoriesSet-up for remote connectivity with ModBus/Echelon/Bacnet protocol cards

Remote keyboard (distance to 200m and to 500m)

Soft starters

Electronic expansion valve

Rubber anti-vibration mounting kit. Spring anti-vibration mounting kit

FeaturesREFRIGERANT GAS R410A

The use of R410A has resulted in units offering better energy efficiency in full respect for the environment (ODP = 0)

TOTAL VERSATILITY

Climaveneta is the only company to offer units with Scroll compressors in 5 versions and 3 different configurations designed to satisfy all service system and application requirements

SHELL AND TUBES EXCHANGER

The shell and tube exchanger allows to achieve the highest flexibility on the units installation, keeping the efficiency at the maximum level. For this reason, NECS represents the best choice for all the hydronic application on the residential, commercial and industrial markets.

INTEGRATED HYDRONIC MODULE

The built-in hydronic module already contains the main water circuit components; it is available with single or twin in-line, for achieving both low or high head.

Configurations- base function

D partial condensing heat recovery function

R total condensing heat recovery function

VersionsB base version

HL low noise, high efficiency, high outdoor temperature version

HT high efficiency, high outdoor temperature version

LN low noise version

SL super-low noise version

CommandsW3000SE CompactThe W3000SE Compact controller offers advanced functions and algorithms. The keypad features an easy-to-use interface and a complete LCD display, allowing to consult and intervene on the unit by means of a multi-level menu, with selectable language setting. The regulation is based on the exclusive QuickMind algorithm, including self-adaptive control logics, beneficial in low water content systems. As alternatives the proportional- or proportional-integral regulations are also available. The diagnostics includes a complete alarm management, with the “black-box” and alarm logging functions for enhanced analysis of the unit operation. For multiple units systems, the regulation of the resources, via optional proprietary devices, can be implemented. Energy metering, for both consumption and capacity, can also be developed. Supervision can be easily developed via proprietary devices or the integration in third party systems by means of the most common protocols as ModBus, Bacnet, Bacnet-over-IP, Echelon LonWorks. Compatibility with the remote keyboard managing up to 10 units. Availability of an internal real time clock for operation scheduling (4-day profiles with 10 hour belts). All /R units adopt the W3000 SE Large controller.

Hydronic - chiller

NECS-ST 0504÷1204

Chiller, air source for outdoor installation

104 - 341 kWUnit DescriptionOutdoor unit for the production of chilled water with hermetic rotary Scroll compressors, axial-flow fans, shell and tubes exchanger and thermostatic expansion valve. External panels in Peraluman and structure in aluminium sections. The range is equipped with four compressors on two independent refrigerant circuits.

Page 93: Products Guide V01 - ParagonEfficient project management thanks to Climaveneta as unique project leader. Complete and specialized Organization Climaveneta qualifies itself for the

91

Note:

1 Evaporator water (in/out) = 12/7°C; Condenser air (in) = 35°C.

2 Evaporator water (in/out) = 12/7°C; Condenser air (in) = 35°C; Desuperheater water (in/out) = 40/45°C.

3 Evaporator water (in/out) = 12/7°C; Recovery unit water (in/out) = 40/45°C

4 Sound power on the basis of measurements made in compliance with ISO 9614 and Eurovent 8/1 for Eurovent certified units; in compliance with ISO 3744 for non-certified units.

5 Average sound pressure level, at 10m distance, unit in a free field on a reflective surface; non-binding value obtained from the sound power level.

6 Unit in standard configuration/execution, without optional accessories

NECS-ST / HLModels 0504 0524 0604 0704 0804 0904 1004 1104 1204COOLINGCooling capacity (1) kW 118 136 151 172 201 222 249 290 326Total power input (1) kW 43,7 49,8 58,1 66,7 72,8 83,8 91,9 102 117EER 2,70 2,73 2,60 2,58 2,76 2,65 2,71 2,83 2,77ESEER 3,93 4,04 4,02 4,15 4,02 4,04 4,14 4,37 4,16COOLING WITH PARTIAL RECOVERYCooling capacity (2) kW 123 141 157 178 209 231 258 301 338Total power input (2) kW 42,4 48,4 56,2 64,4 70,7 81,1 88,8 99,1 104Desuperheater heating capacity (2) kW 34,8 40,4 47,5 55,1 58,7 68,3 75,5 85,1 96,5COOLING WITH TOTAL RECOVERYCooling capacity (3) kW 118 138 158 181 204 231 258 295 333Total power input (3) kW 38,7 44,1 49,4 56,9 64,5 72,1 79,8 92,8 105Heat recovery capacity (3) kW 155 179 204 234 264 299 333 382 431COMPRESSORSNo. Compressors/No. Circuits N. 4/2 4/2 4/2 4/2 4/2 4/2 4/2 4/2 4/2NOISE LEVELSSound power (4) dB(A) 86 86 86 86 88 88 88 90 91Sound pressure (5) dB(A) 54 54 54 54 56 56 56 58 59SIZEA (6) mm 3110 3110 3110 3110 4110 4110 4110 5110 5110B (6) mm 2220 2220 2220 2220 2220 2220 2220 2220 2220H (6) mm 1700 2150 2150 2150 2150 2150 2150 2150 2150Operating weight (6) kg 1360 1570 1710 1860 2120 2180 2320 2630 2770

Note:

1 Evaporator water (in/out) = 12/7°C; Condenser air (in) = 35°C.

2 Evaporator water (in/out) = 12/7°C; Condenser air (in) = 35°C; Desuperheater water (in/out) = 40/45°C.

3 Evaporator water (in/out) = 12/7°C; Recovery unit water (in/out) = 40/45°C

4 Sound power on the basis of measurements made in compliance with ISO 9614 and Eurovent 8/1 for Eurovent certified units; in compliance with ISO 3744 for non-certified units.

5 Average sound pressure level, at 10m distance, unit in a free field on a reflective surface; non-binding value obtained from the sound power level.

6 Unit in standard configuration/execution, without optional accessories

NECS-ST / BModels 0504 0524 0604 0704 0804 0904 1004 1104 1204COOLINGCooling capacity (1) kW 113 136 154 177 200 223 255 293 325Total power input (1) kW 45,6 53,8 59,7 67,8 74,9 84,2 94,1 106 121EER 2,48 2,53 2,58 2,61 2,67 2,65 2,71 2,76 2,68ESEER 4,10 3,60 3,79 3,91 4,08 4,15 3,96 4,10 4,16COOLING WITH PARTIAL RECOVERYCooling capacity (2) kW 118 141 160 183 207 232 265 304 337Total power input (2) kW 40 43,8 49,6 57,2 64,2 73,3 78,7 90,4 105Desuperheater heating capacity (2) kW 37 40,5 45,9 53 59,4 67,8 72,8 83,6 97COOLING WITH TOTAL RECOVERYCooling capacity (3) kW 118 138 158 181 204 231 258 295 333Total power input (3) kW 38,7 44,1 49,4 56,9 64,5 72,1 79,8 92,8 105Heat recovery capacity (3) kW 155 179 204 234 264 299 333 382 431COMPRESSORSNo. Compressors/No. Circuits N. 4/2 4/2 4/2 4/2 4/2 4/2 4/2 4/2 4/2NOISE LEVELSSound power (4) dB(A) 91 92 92 92 92 93 94 95 95Sound pressure (5) dB(A) 59 60 60 60 60 61 62 63 63SIZEA (6) mm 3110 3110 3110 3110 3110 4110 4110 4110 4110B (6) mm 2220 2220 2220 2220 2220 2220 2220 2220 2220H (6) mm 1700 1700 1700 2150 2150 2150 2150 2150 2150Operating weight (6) kg 1230 1450 1620 1780 1890 2070 2220 2380 2530

COOLING

r HFCR-410A

SCROLLAXIALSHELL & TUBES

Page 94: Products Guide V01 - ParagonEfficient project management thanks to Climaveneta as unique project leader. Complete and specialized Organization Climaveneta qualifies itself for the

92

Note:

1 Evaporator water (in/out) = 12/7°C; Condenser air (in) = 35°C.

2 Evaporator water (in/out) = 12/7°C; Condenser air (in) = 35°C; Desuperheater water (in/out) = 40/45°C.

3 Evaporator water (in/out) = 12/7°C; Recovery unit water (in/out) = 40/45°C

4 Sound power on the basis of measurements made in compliance with ISO 9614 and Eurovent 8/1 for Eurovent certified units; in compliance with ISO 3744 for non-certified units.

5 Average sound pressure level, at 10m distance, unit in a free field on a reflective surface; non-binding value obtained from the sound power level.

6 Unit in standard configuration/execution, without optional accessories

NECS-ST / LNModels 0504 0524 0604 0704 0804 0904 1004 1104 1204COOLINGCooling capacity (1) kW 104 129 147 167 187 208 242 275 306Total power input (1) kW 47,9 53,5 60 69,6 77,6 87,8 95,3 109 125EER 2,17 2,41 2,45 2,40 2,41 2,37 2,54 2,52 2,44ESEER 3,93 3,84 3,91 4,01 3,99 4,07 4,01 4,15 4,06COOLING WITH PARTIAL RECOVERYCooling capacity (2) kW 108 134 153 173 194 216 251 286 317Total power input (2) kW 46,6 51,8 58,2 67,1 75,3 85,2 92 106 121Desuperheater heating capacity (2) kW 40,9 43,5 49,3 57,6 65,2 74,4 78,4 91,3 105COOLING WITH TOTAL RECOVERYCooling capacity (3) kW 118 138 158 181 204 231 258 295 333Total power input (3) kW 38,7 44,1 49,4 56,9 64,5 72,1 79,8 92,8 105Heat recovery capacity (3) kW 155 179 204 234 264 299 333 382 431COMPRESSORSNo. Compressors/No. Circuits N. 4/2 4/2 4/2 4/2 4/2 4/2 4/2 4/2 4/2NOISE LEVELSSound power (4) dB(A) 85 86 86 86 86 87 88 89 89Sound pressure (5) dB(A) 53 54 54 54 54 55 56 57 57SIZEA (6) mm 3110 3110 3110 3110 3110 4110 4110 4110 4110B (6) mm 2220 2220 2220 2220 2220 2220 2220 2220 2220H (6) mm 1700 1700 1700 2150 2150 2150 2150 2150 2150Operating weight (6) kg 1230 1450 1620 1780 1890 2070 2220 2380 2530

Note:

1 Evaporator water (in/out) = 12/7°C; Condenser air (in) = 35°C.

2 Evaporator water (in/out) = 12/7°C; Condenser air (in) = 35°C; Desuperheater water (in/out) = 40/45°C.

3 Evaporator water (in/out) = 12/7°C; Recovery unit water (in/out) = 40/45°C

4 Sound power on the basis of measurements made in compliance with ISO 9614 and Eurovent 8/1 for Eurovent certified units; in compliance with ISO 3744 for non-certified units.

5 Average sound pressure level, at 10m distance, unit in a free field on a reflective surface; non-binding value obtained from the sound power level.

6 Unit in standard configuration/execution, without optional accessories

NECS-ST / HTModels 0504 0524 0604 0704 0804 0904 1004 1104 1204COOLINGCooling capacity (1) kW 123 142 159 182 210 233 262 303 341Total power input (1) kW 45,4 50,5 57,8 65 74,5 84,1 90,7 101 117EER 2,71 2,81 2,75 2,80 2,82 2,77 2,89 2,99 2,91ESEER 3,63 3,76 3,90 4,02 3,82 3,86 4,08 4,25 4,08COOLING WITH PARTIAL RECOVERYCooling capacity (2) kW 127 147 165 189 218 242 272 315 354Total power input (2) kW 44 49,2 55,9 63 72,2 81,5 88,1 98,4 114Desuperheater heating capacity (2) kW 32,9 37,7 43,9 50,5 55,1 63,8 69,8 85,8 97,1COOLING WITH TOTAL RECOVERYCooling capacity (3) kW 118 138 158 181 204 231 258 295 333Total power input (3) kW 38,7 44,1 49,4 56,9 64,5 72,1 79,8 92,8 105Heat recovery capacity (3) kW 155 179 204 234 264 299 333 382 431COMPRESSORSNo. Compressors/No. Circuits N. 4/2 4/2 4/2 4/2 4/2 4/2 4/2 4/2 4/2NOISE LEVELSSound power (4) dB(A) 92 92 92 92 94 94 94 96 97Sound pressure (5) dB(A) 60 60 60 60 62 62 62 64 65SIZEA (6) mm 3110 3110 3110 3110 4110 4110 4110 5110 5110B (6) mm 2220 2220 2220 2220 2220 2220 2220 2220 2220H (6) mm 1700 2150 2150 2150 2150 2150 2150 2150 2150Operating weight (6) kg 1360 1570 1710 1860 2120 2180 2320 2630 2770

Page 95: Products Guide V01 - ParagonEfficient project management thanks to Climaveneta as unique project leader. Complete and specialized Organization Climaveneta qualifies itself for the

93

Minimum clearance required0504-1204

Switchboard side mm 1100Switchboard opposite side mm 1100Condensation coil side mm 2000

Note:

1 Evaporator water (in/out) = 12/7°C; Condenser air (in) = 35°C.

2 Evaporator water (in/out) = 12/7°C; Condenser air (in) = 35°C; Desuperheater water (in/out) = 40/45°C.

3 Evaporator water (in/out) = 12/7°C; Recovery unit water (in/out) = 40/45°C

4 Sound power on the basis of measurements made in compliance with ISO 9614 and Eurovent 8/1 for Eurovent certified units; in compliance with ISO 3744 for non-certified units.

5 Average sound pressure level, at 10m distance, unit in a free field on a reflective surface; non-binding value obtained from the sound power level.

6 Unit in standard configuration/execution, without optional accessories

NECS-ST / SLModels 0504 0524 0604 0704 0804 0904 1004 1104 1204COOLINGCooling capacity (1) kW 113 130 147 161 193 211 235 278 313Total power input (1) kW 45,2 51,8 58,8 70,6 75,4 87,2 96,7 106 121EER 2,50 2,51 2,50 2,28 2,56 2,42 2,43 2,61 2,58ESEER 4,02 4,14 4,14 4,13 4,08 4,08 4,10 4,39 4,19COOLING WITH PARTIAL RECOVERYCooling capacity (2) kW 117 135 152 167 200 219 243 288 325Total power input (2) kW 43,7 50,2 56,9 68,4 72,8 84,3 93,2 103 117Desuperheater heating capacity (2) kW 37,2 43,2 49,5 60,1 62,6 73,2 81,5 90,2 102COOLING WITH TOTAL RECOVERYCooling capacity (3) kW 118 138 158 181 204 231 258 295 325Total power input (3) kW 38,7 44,1 49,4 56,9 64,5 72,1 79,8 92,8 105Heat recovery capacity (3) kW 155 179 204 234 264 298 333 382 431COMPRESSORSNo. Compressors/No. Circuits N. 4/2 4/2 4/2 4/2 4/2 4/2 4/2 4/2 4/2NOISE LEVELSSound power (4) dB(A) 82 82 82 82 83 83 83 85 86Sound pressure (5) dB(A) 50 50 50 50 51 51 51 53 54SIZEA (6) mm 3110 3110 3110 3110 4110 4110 4110 5110 5110B (6) mm 2220 2220 2220 2220 2220 2220 2220 2220 2220H (6) mm 1700 2150 2150 2150 2150 2150 2150 2150 2150Operating weight (6) kg 1360 1570 1770 1860 2120 2180 2320 2630 2770

AB

H

Page 96: Products Guide V01 - ParagonEfficient project management thanks to Climaveneta as unique project leader. Complete and specialized Organization Climaveneta qualifies itself for the

94

Main accessoriesSoft start

Compressor power factor device

Electronic expansion valve

Variable speed condensation control (standard on /LN, /SL)

Remote keyboard (distance to 200m and to 500m)

Set-up for remote connectivity with ModBus, Echelon LonTalk, Bacnet protocol board

Hydronic group with possible storage tank

FeaturesFLEXIBILITY

Flexibility in applications thanks to the many available functions and versions

ADAPTABILITY

Adaptability at the buildings cooling request thanks to the continuous capacity regulation, assured by sophisticated controls logic

EXTENSIVE RANGE OF OPERATION

Extensive range of operation with external air temperature up to 46°C at full load; with total heat recovery, hot water can be produced up to a temperature of 55°C.

INTEGRATED HYDRONIC MODULE

Optional pump unit also with storage tank, consisting of 1 or 2 pumps, 2 or 4-pole motor, with three head options to satisfy different industrial applications and demands for comfort

Configurations- base function

D partial condensing heat recovery function

R total condensing heat recovery function

VersionsB base version

LN low noise version

SL super-low noise version

CommandsW3000SE LargeThe W3000 SE Large controller offers advanced functions and algorithms. The keypad is generously sized with full operating status display. The commands and detailed LCD display make access to the units settings easy and safe. These resources allow to consult and intervene on the unit by means of a multi-level menu, with selectable language setting. The diagnostics includes a complete alarm management, with the “black-box” and alarm logging functions for enhanced analysis of the unit operation. For multiple units systems, the regulation of the resources, via optional proprietary devices, can be implemented. Energy metering, for both consumption and capacity, can also be developed. Supervision can be easily developed via proprietary devices or the integration in third party systems by means of the most common protocols as ModBus, Bacnet, Bacnet-over-IP, Echelon LonWorks. Compatibility with the remote keyboard managing up to 10 units. Availability of an internal real time clock for operation scheduling (4-day profiles with 10 hour belts). The regulation features the continuous modulation of capacity, based on a dynamic dead band and referring to the leaving water temperature. As alternative, step-wise regulation is also available, referred to the return water temperature with selectable proportional- or proportional-integral logic.

Hydronic - chiller

FOCS 0751÷2632

Chiller, air source for outdoor installation

145 - 516 kWUnit DescriptionOutdoor unit for the production of chilled water with semi-hermetic screw compressors optimized for R134a, axial-flow fans, condensing coil with copper tubes and aluminium fins, plate evaporator and thermostatic expansion valve. Frame with base in polyester-painted thick hot-galvanised sheet steel and external panels in peraluman. Flexible and reliable unit; it easily adapts itself to different thermal load conditions thanks to the precise thermoregulation. The high performances level is achieved thanks to the accurate sizing of all internal components.

Page 97: Products Guide V01 - ParagonEfficient project management thanks to Climaveneta as unique project leader. Complete and specialized Organization Climaveneta qualifies itself for the

95

Note:

1 Evaporator water (in/out) = 12/7°C; Condenser air (in) = 35°C.

2 Evaporator water (in/out) = 12/7°C; Condenser air (in) = 35°C; Desuperheater water (in/out) = 40/45°C.

3 Evaporator water (in/out) = 12/7°C; Recovery unit water (in/out) = 40/45°C

4 Sound power on the basis of measurements made in compliance with ISO 9614 and Eurovent 8/1 for Eurovent certified units; in compliance with ISO 3744 for non-certified units.

5 Average sound pressure level, at 10m distance, unit in a free field on a reflective surface; non-binding value obtained from the sound power level.

6 Unit in standard configuration/execution, without optional accessories

FOCS / LNModels 0751 0851 0951 0961 1021 1301 1532 1732 1932 1952 2432 2632COOLINGCooling capacity (1) kW 141 157 175 195 229 256 266 310 345 376 440 483Total power input (1) kW 51,3 61,1 70 77,4 86,7 94,8 105 124 143 164 185 201EER 2,75 2,57 2,50 2,52 2,64 2,70 2,51 2,50 2,40 2,29 2,37 2,40ESEER 3,69 3,51 3,57 3,69 3,65 3,59 3,68 3,58 3,61 3,61 3,62 3,48COOLING WITH PARTIAL RECOVERYCooling capacity (2) kW 146 162 181 202 237 265Total power input (2) kW 49,3 59 67,6 74,8 83,7 91,4Desuperheater heating capacity (2) kW 42,5 51,4 59,4 66,1 72,7 79,9COOLING WITH TOTAL RECOVERYCooling capacity (3) kW 139 157 172 205 231 247Total power input (3) kW 51,5 60,6 71 73,7 87,3 98Heat recovery capacity (3) kW 45,1 53,5 63,2 64,3 76,9 86,9COMPRESSORSNo. Compressors/No. Circuits N. 1/1 1/1 1/1 1/1 1/1 1/1 2/2 2/2 2/2 2/2 2/2 2/2NOISE LEVELSSound power (4) dB(A) 88 88 88 88 90 90 91 91 91 91 93 93Sound pressure (5) dB(A) 56 56 56 56 58 58 59 59 59 59 61 61SIZEA (6) mm 3110 3110 3110 3110 4610 4610 4610 4610 4610 4610 5610 5610B (6) mm 2220 2220 2220 2220 2220 2220 2220 2220 2220 2220 2220 2220H (6) mm 2150 2150 2150 2150 2150 2150 2150 2420 2420 2420 2430 2430Operating weight (6) kg 1680 1710 1780 1860 2590 2720 2970 3160 3300 3320 4400 4620

Note:

1 Evaporator water (in/out) = 12/7°C; Condenser air (in) = 35°C.

2 Evaporator water (in/out) = 12/7°C; Condenser air (in) = 35°C; Desuperheater water (in/out) = 40/45°C.

3 Evaporator water (in/out) = 12/7°C; Recovery unit water (in/out) = 40/45°C

4 Sound power on the basis of measurements made in compliance with ISO 9614 and Eurovent 8/1 for Eurovent certified units; in compliance with ISO 3744 for non-certified units.

5 Average sound pressure level, at 10m distance, unit in a free field on a reflective surface; non-binding value obtained from the sound power level.

6 Unit in standard configuration/execution, without optional accessories

FOCS / BModels 0751 0851 0951 0961 1021 1301 1532 1732 1932 1952 2432 2632COOLINGCooling capacity (1) kW 145 163 182 201 234 266 277 329 366 398 466 516Total power input (1) kW 51,6 61,1 68,4 75 85,1 93,3 103 121 138 154 178 193EER 2,81 2,67 2,66 2,68 2,75 2,85 2,67 2,71 2,64 2,58 2,61 2,67ESEER 3,50 3,42 3,52 3,63 3,49 3,54 3,64 3,57 3,56 3,58 3,61 3,49COOLING WITH PARTIAL RECOVERYCooling capacity (2) kW 150 169 189 209 243 276Total power input (2) kW 49,9 59 66,5 72,7 82,7 90,5Desuperheater heating capacity (2) kW 40,8 49,2 56,2 61,8 68,4 75,7COOLING WITH TOTAL RECOVERYCooling capacity (3) kW 148 171 190 211 241 275Total power input (3) kW 43,8 51 59,3 61,6 70,1 80,4Heat recovery capacity (3) kW 190 220 246 269 307 351COMPRESSORSNo. Compressors/No. Circuits N. 1/1 1/1 1/1 1/1 1/1 1/1 2/2 2/2 2/2 2/2 2/2 2/2NOISE LEVELSSound power (4) dB(A) 94 94 94 94 96 96 97 97 97 97 99 99Sound pressure (5) dB(A) 62 62 62 62 64 64 65 65 65 65 67 67SIZEA (6) mm 3110 3110 3110 3110 4610 4610 4610 4610 4610 4610 5610 5610B (6) mm 2220 2220 2220 2220 2220 2220 2220 2220 2220 2220 2220 2220H (6) mm 2150 2150 2150 2150 2150 2150 2150 2420 2420 2420 2430 2430Operating weight (6) kg 1680 1710 1780 1860 2590 2720 2970 3160 3300 3320 4400 4620

COOLING

r HFCR-134a

SCREWAXIALPLATES

Page 98: Products Guide V01 - ParagonEfficient project management thanks to Climaveneta as unique project leader. Complete and specialized Organization Climaveneta qualifies itself for the

96

Minimum clearance required0751-1952 2432-2632

Switchboard side mm 1500 2000Switchboard opposite side mm 1500 1800Condensation coil side mm 2000 3000

Note:

1 Evaporator water (in/out) = 12/7°C; Condenser air (in) = 35°C.

2 Evaporator water (in/out) = 12/7°C; Condenser air (in) = 35°C; Desuperheater water (in/out) = 40/45°C.

3 Evaporator water (in/out) = 12/7°C; Recovery unit water (in/out) = 40/45°C

4 Sound power on the basis of measurements made in compliance with ISO 9614 and Eurovent 8/1 for Eurovent certified units; in compliance with ISO 3744 for non-certified units.

5 Average sound pressure level, at 10m distance, unit in a free field on a reflective surface; non-binding value obtained from the sound power level.

6 Unit in standard configuration/execution, without optional accessories

FOCS / SLModels 0751 0851 0951 0961 1021 1301 1532 1732 1932 1952 2432 2632COOLINGCooling capacity (1) kW 134 151 166 197 223 238 252 296 334 377 443 484Total power input (1) kW 53,2 62,7 73,8 76,1 90,3 101 111 128 149 164 183 199EER 2,52 2,41 2,25 2,59 2,47 2,35 2,26 2,31 2,24 2,29 2,41 2,43ESEER 3,54 3,41 3,40 3,69 3,58 3,32 3,50 3,47 3,46 3,62 3,69 3,52COOLING WITH PARTIAL RECOVERYCooling capacity (2) kW 148 172 190 211 241 275Total power input (2) kW 43,8 51 59,3 61,6 70,1 80,4Desuperheater heating capacity (2) kW 190 220 246 269 307 351COOLING WITH TOTAL RECOVERYCooling capacity (3) kW 148 172 190 211 241 275Total power input (3) kW 43,8 51 59,3 61,6 70,1 80,4Heat recovery capacity (3) kW 190 220 246 269 307 351COMPRESSORSNo. Compressors/No. Circuits N. 1/1 1/1 1/1 1/1 1/1 1/1 2/2 2/2 2/2 2/2 2/2 2/2NOISE LEVELSSound power (4) dB(A) 84 84 84 84 86 86 86 87 87 87 89 89Sound pressure (5) dB(A) 52 52 52 52 54 54 54 55 55 55 56 56SIZEA (6) mm 3110 3110 3110 4110 4610 4610 4610 4610 5610 5610 6610 6610B (6) mm 2220 2220 2220 2220 2220 2220 2220 2220 2220 2220 2220 2220H (6) mm 2150 2150 2150 2150 2150 2150 2150 2420 2430 2430 2430 2430Operating weight (6) kg 1680 1770 1840 1980 2670 2720 3060 3270 3460 3640 4990 5250

Page 99: Products Guide V01 - ParagonEfficient project management thanks to Climaveneta as unique project leader. Complete and specialized Organization Climaveneta qualifies itself for the

97

Page 100: Products Guide V01 - ParagonEfficient project management thanks to Climaveneta as unique project leader. Complete and specialized Organization Climaveneta qualifies itself for the

98

Main accessoriesSoft start

Compressor power factor device

Electronic expansion valve

Variable speed condensation control (standard on /LN, /SL)

Remote keyboard (distance to 200m and to 500m)

Set-up for remote connectivity with ModBus, Echelon LonTalk, Bacnet protocol board

FeaturesFLEXIBILITY

Flexibility in applications thanks to the many available functions and versions

ADAPTABILITY

Adaptability at the buildings cooling request thanks to the continuous capacity regulation, assured by sophisticated controls logic

EXTENSIVE RANGE OF OPERATION

Extensive range of operation with external air temperature up to 46°C at full load; with total heat recovery, hot water can be produced up to a temperature of 55°C.

Configurations- base function

D partial condensing heat recovery function

R total condensing heat recovery function

VersionsB base version

LN low noise version

SL super-low noise version

CommandsW3000SE LargeThe W3000 SE Large controller offers advanced functions and algorithms. The keypad is generously sized with full operating status display. The commands and detailed LCD display make access to the units settings easy and safe. These resources allow to consult and intervene on the unit by means of a multi-level menu, with selectable language setting. The diagnostics includes a complete alarm management, with the “black-box” and alarm logging functions for enhanced analysis of the unit operation. For multiple units systems, the regulation of the resources, via optional proprietary devices, can be implemented. Energy metering, for both consumption and capacity, can also be developed. Supervision can be easily developed via proprietary devices or the integration in third party systems by means of the most common protocols as ModBus, Bacnet, Bacnet-over-IP, Echelon LonWorks. Compatibility with the remote keyboard managing up to 10 units. Availability of an internal real time clock for operation scheduling (4-day profiles with 10 hour belts). The regulation features the continuous modulation of capacity, based on a dynamic dead band and referring to the leaving water temperature. As alternative, step-wise regulation is also available, referred to the return water temperature with selectable proportional- or proportional-integral logic.

Hydronic - chiller

FOCS 1542÷2642

Chiller, air source for outdoor installation

277 - 516 kWUnit DescriptionOutdoor unit for the production of chilled water with semi-hermetic screw compressors optimized for R134a, axial-flow fans, condensing coil with copper tubes and aluminium fins, shell and tubes evaporator designed by Climaveneta and thermostatic expansion valve. Frame with base in polyester-painted thick hot-galvanised sheet steel and external panels in peraluman. Flexible and reliable unit; it easily adapts itself to different thermal load conditions thanks to the precise thermoregulation. The high performances level is achieved thanks to the accurate sizing of all internal components.

Page 101: Products Guide V01 - ParagonEfficient project management thanks to Climaveneta as unique project leader. Complete and specialized Organization Climaveneta qualifies itself for the

99

Minimum clearance required1542-2642

Switchboard side mm 1500Switchboard opposite side mm 1500Condensation coil side mm 2000

Note:

1 Evaporator water (in/out) = 12/7°C; Condenser air (in) = 35°C.

2 Sound power on the basis of measurements made in compliance with ISO 9614 and Eurovent 8/1 for Eurovent certified units; in compliance with ISO 3744 for non-certified units.

3 Average sound pressure level, at 10m distance, unit in a free field on a reflective surface; non-binding value obtained from the sound power level.

4 Unit in standard configuration/execution, without optional accessories

FOCS / SLModels 1542 1742 1942 1962 2442 2642COOLINGCooling capacity (1) kW 252 296 334 377 443 484Total power input (1) kW 111 128 149 164 183 199EER 2,26 2,31 2,24 2,29 2,41 2,43ESEER 3,50 3,47 3,46 3,62 3,69 3,52COMPRESSORSNo. Compressors/No. Circuits N. 2/2 2/2 2/2 2/2 2/2 2/2NOISE LEVELSSound power (2) dB(A) 86 87 87 87 89 89Sound pressure (3) dB(A) 54 55 55 55 56 56SIZEA (4) mm 4610 4610 5610 5610 6610 6610B (4) mm 2220 2220 2220 2220 2220 2220H (4) mm 2150 2420 2430 2430 2430 2430Operating weight (4) kg 3580 3790 3960 4410 5730 5970

Note:

1 Evaporator water (in/out) = 12/7°C; Condenser air (in) = 35°C.

2 Sound power on the basis of measurements made in compliance with ISO 9614 and Eurovent 8/1 for Eurovent certified units; in compliance with ISO 3744 for non-certified units.

3 Average sound pressure level, at 10m distance, unit in a free field on a reflective surface; non-binding value obtained from the sound power level.

4 Unit in standard configuration/execution, without optional accessories

FOCS / LNModels 1542 1742 1942 1962 2442 2642COOLINGCooling capacity (1) kW 266 310 345 376 440 483Total power input (1) kW 105 124 143 164 185 201EER 2,51 2,50 2,40 2,29 2,37 2,40ESEER 3,68 3,58 3,61 3,61 3,62 3,48COMPRESSORSNo. Compressors/No. Circuits N. 2/2 2/2 2/2 2/2 2/2 2/2NOISE LEVELSSound power (2) dB(A) 91 91 91 91 93 93Sound pressure (3) dB(A) 59 59 59 59 61 61SIZEA (4) mm 4610 4610 4610 4610 5610 5610B (4) mm 2220 2220 2220 2220 2220 2220H (4) mm 2150 2420 2420 2420 2430 2430Operating weight (4) kg 3490 3680 3810 4100 5140 5340

Note:

1 Evaporator water (in/out) = 12/7°C; Condenser air (in) = 35°C.

2 Sound power on the basis of measurements made in compliance with ISO 9614 and Eurovent 8/1 for Eurovent certified units; in compliance with ISO 3744 for non-certified units.

3 Average sound pressure level, at 10m distance, unit in a free field on a reflective surface; non-binding value obtained from the sound power level.

4 Unit in standard configuration/execution, without optional accessories

FOCS / BModels 1542 1742 1942 1962 2442 2642COOLINGCooling capacity (1) kW 277 329 366 398 466 516Total power input (1) kW 103 121 138 154 178 193EER 2,67 2,71 2,64 2,58 2,61 2,67ESEER 3,64 3,57 3,56 3,58 3,61 3,49COMPRESSORSNo. Compressors/No. Circuits N. 2/2 2/2 2/2 2/2 2/2 2/2NOISE LEVELSSound power (2) dB(A) 97 97 97 97 99 99Sound pressure (3) dB(A) 65 65 65 65 67 67SIZEA (4) mm 4610 4610 4610 4610 4610 4610B (4) mm 2220 2220 2220 2220 2220 2220H (4) mm 2150 2150 2150 2150 2150 2150Operating weight (4) kg 3490 3680 3810 4100 5140 5340

COOLING

r HFCR-134a

SCREWAXIALSHELL & TUBES

Page 102: Products Guide V01 - ParagonEfficient project management thanks to Climaveneta as unique project leader. Complete and specialized Organization Climaveneta qualifies itself for the

100

Main accessoriesSoft start

Compressor power factor device

Electronic expansion valve

Variable speed condensation control (standard on /LN, /SL)

Remote keyboard (distance to 200m and to 500m)

Set-up for remote connectivity with ModBus, Echelon LonTalk, Bacnet protocol board

Hydronic group

VPF (Variable Primary Flow) kit: variable flow pumps with on board regulation

FeaturesFLEXIBILITY

Flexibility in applications thanks to the many available functions and versions

ADAPTABILITY

Adaptability at the buildings cooling request thanks to the continuous capacity regulation, assured by sophisticated controls logic

EXTENSIVE RANGE OF OPERATION

Extensive range of operation with external air temperature up to 46°C at full load; with total heat recovery, hot water can be produced up to a temperature of 55°C.

INTEGRATED HYDRONIC MODULE

It consists of 2 pumps, 2 or 4-pole motor, fixed or variable speed, with high or low head options to satisfy different industrial applications and demands for comfort.

Configurations- base function

D partial condensing heat recovery function

R total condensing heat recovery function

VersionsB base version

LN low noise version

SL super-low noise version

CommandsW3000SE LargeThe W3000 SE Large controller offers advanced functions and algorithms. The keypad is generously sized with full operating status display. The commands and detailed LCD display make access to the units settings easy and safe. These resources allow to consult and intervene on the unit by means of a multi-level menu, with selectable language setting. The diagnostics includes a complete alarm management, with the “black-box” and alarm logging functions for enhanced analysis of the unit operation. For multiple units systems, the regulation of the resources, via optional proprietary devices, can be implemented. Energy metering, for both consumption and capacity, can also be developed. Supervision can be easily developed via proprietary devices or the integration in third party systems by means of the most common protocols as ModBus, Bacnet, Bacnet-over-IP, Echelon LonWorks. Compatibility with the remote keyboard managing up to 10 units. Availability of an internal real time clock for operation scheduling (4-day profiles with 10 hour belts). The regulation features the continuous modulation of capacity, based on a dynamic dead band and referring to the leaving water temperature. As alternative, step-wise regulation is also available, referred to the return water temperature with selectable proportional- or proportional-integral logic. As option (VPF package), the modulation of capacity is integrated with the modulation of the water flow, by means of inverter and dedicated resources for the hydraulic circuit.

Hydronic - chiller

FOCS 1502÷8404

Chiller, air source for outdoor installation

294 - 1744 kWUnit DescriptionOutdoor unit for the production of chilled water with semi-hermetic screw compressors optimized for R134a, axial-flow fans, condensing coil with copper tubes and aluminium fins, shell and tubes evaporator designed by Climaveneta and thermostatic expansion valve. Base and supporting structure and panels are of galvanized epoxy powder coated steel with increased thickness. Flexible and reliable unit; it easily adapts itself to different thermal load conditions thanks to the precise thermoregulation. The high performances level is achieved thanks to the accurate sizing of all internal components.

Page 103: Products Guide V01 - ParagonEfficient project management thanks to Climaveneta as unique project leader. Complete and specialized Organization Climaveneta qualifies itself for the

101

Note:

1 Evaporator water (in/out) = 12/7°C; Condenser air (in) = 35°C.

2 Evaporator water (in/out) = 12/7°C; Condenser air (in) = 35°C; Desuperheater water (in/out) = 40/45°C.

3 Evaporator water (in/out) = 12/7°C; Recovery unit water (in/out) = 40/45°C

4 Sound power on the basis of measurements made in compliance with ISO 9614 and Eurovent 8/1 for Eurovent certified units; in compliance with ISO 3744 for non-certified units.

5 Average sound pressure level, at 10m distance, unit in a free field on a reflective surface; non-binding value obtained from the sound power level.

6 Unit in standard configuration/execution, without optional accessories

Models 3902 4202 4212 4222 4822 5702 6002 6022 6903 7203 7223 8404COOLINGCooling capacity (1) kW 831 900 972 1039 1156 1213 1251 1338 1433 1485 1608 1744Total power input (1) kW 302 321 334 346 384 423 441 473 519 536 593 643EER 2,75 2,80 2,91 3 3,01 2,87 2,83 2,83 2,76 2,77 2,71 2,71ESEER 3,78 3,79 3,78 3,90 4,14 3,99 3,85 3,99 3,68 3,82 3,79 3,66COOLING WITH PARTIAL RECOVERYCooling capacity (2) kW 862 934 1008 1078 1200 1259 1298 1388 1487 1541 1669 1809Total power input (2) kW 292 311 323 335 372 409 427 458 504 519 574 622Desuperheater heating capacity (2) kW 251 269 272 283 317 351 368 391 419 433 484 529COOLING WITH TOTAL RECOVERYCooling capacity (3) kW 868 948 993 1056 1179 1267 1320 1382 1490 1544 1659 1861Total power input (3) kW 262 279 283 295 334 368 379 408 439 453 493 556Heat recovery capacity (3) kW 1115 1211 1260 1333 1494 1613 1676 1766 1903 1970 2123 2383COMPRESSORSNo. Compressors/No. Circuits N. 2/2 2/2 2/2 2/2 2/2 2/2 2/2 2/2 3/3 3/3 3/3 4/4NOISE LEVELSSound power (4) dB(A) 102 102 103 103 104 105 105 105 105 105 105 105Sound pressure (5) dB(A) 69 69 70 70 71 72 72 72 72 72 72 72SIZEA (6) mm 7000 7000 9400 9400 9400 9400 9400 11200 11200 11200 11200 11200B (6) mm 2260 2260 2260 2260 2260 2260 2260 2260 2260 2260 2260 2260H (6) mm 2430 2430 2430 2430 2430 2430 2430 2430 2430 2430 2430 2430Operating weight (6) kg 8470 8610 9430 9690 10110 * * * 12390 12530 12670 16360

FOCS / BModels 1502 1702 1902 1922 1972 2022 2602 2652 2702 2712 2722 3152 3602COOLINGCooling capacity (1) kW 294 328 364 414 439 480 529 562 598 625 681 730 785Total power input (1) kW 101 120 133 146 156 160 184 195 207 217 221 259 289EER 2,91 2,73 2,72 2,82 2,80 3 2,86 2,88 2,88 2,88 3,08 2,82 2,72ESEER 3,86 3,75 3,74 3,85 3,84 3,88 3,76 3,88 3,98 3,89 4,07 3,94 3,94COOLING WITH PARTIAL RECOVERYCooling capacity (2) kW 305 340 378 429 456 498 549 583 621 648 707 757 814Total power input (2) kW 98 116 129 143 151 155 179 189 201 210 215 252 280Desuperheater heating capacity (2) kW 82 99 109 121 129 130 152 161 172 178 182 217 243COOLING WITH TOTAL RECOVERYCooling capacity (3) kW 301 349 381 425 450 481 547 581 625 651 703 767 826Total power input (3) kW 89 102 118 127 135 136 162 171 180 182 186 219 252Heat recovery capacity (3) kW 385 445 492 545 577 609 699 741 793 823 878 973 1063COMPRESSORSNo. Compressors/No. Circuits N. 2/2 2/2 2/2 2/2 2/2 2/2 2/2 2/2 2/2 2/2 2/2 2/2 2/2NOISE LEVELSSound power (4) dB(A) 98 98 99 99 99 99 99 99 99 101 101 101 101Sound pressure (5) dB(A) 66 66 67 67 67 67 67 67 67 69 69 69 69SIZEA (6) mm 4000 4000 4000 4900 4900 4900 4900 4900 4900 5800 5800 5800 5800B (6) mm 2260 2260 2260 2260 2260 2260 2260 2260 2260 2260 2260 2260 2260H (6) mm 2430 2430 2430 2430 2430 2430 2430 2430 2430 2430 2430 2430 2430Operating weight (6) kg 3760 3790 3880 4360 5050 5560 5560 5660 5770 5940 6270 7360 8040

COOLING

r HFCR-134a

SCREWAXIALSHELL & TUBES

Page 104: Products Guide V01 - ParagonEfficient project management thanks to Climaveneta as unique project leader. Complete and specialized Organization Climaveneta qualifies itself for the

102

Note:

1 Evaporator water (in/out) = 12/7°C; Condenser air (in) = 35°C.

2 Evaporator water (in/out) = 12/7°C; Condenser air (in) = 35°C; Desuperheater water (in/out) = 40/45°C.

3 Evaporator water (in/out) = 12/7°C; Recovery unit water (in/out) = 40/45°C

4 Sound power on the basis of measurements made in compliance with ISO 9614 and Eurovent 8/1 for Eurovent certified units; in compliance with ISO 3744 for non-certified units.

5 Average sound pressure level, at 10m distance, unit in a free field on a reflective surface; non-binding value obtained from the sound power level.

6 Unit in standard configuration/execution, without optional accessories

Models 3902 4202 4212 4222 4822 5702 6002 6022 6903 7203 7223 8404COOLINGCooling capacity (1) kW 808 872 950 1014 1130 1177 1212 1302 1367 1421 1568 1679Total power input (1) kW 305 325 334 352 393 427 448 481 532 549 608 650EER 2,65 2,68 2,84 2,88 2,88 2,75 2,71 2,71 2,57 2,59 2,58 2,58ESEER 3,83 3,81 3,91 4 4,27 3,99 3,91 4,11 3,74 3,90 3,93 3,69COOLING WITH PARTIAL RECOVERYCooling capacity (2) kW 838 904 986 1052 1173 1221 1258 1351 1419 1475 1627 1742Total power input (2) kW 295 314 323 340 380 413 432 465 515 530 588 628Desuperheater heating capacity (2) kW 262 280 283 299 336 366 384 411 449 464 517 554COOLING WITH TOTAL RECOVERYCooling capacity (3) kW 868 949 993 1056 1180 1267 1320 1382 1490 1544 1659 1861Total power input (3) kW 262 279 284 295 334 368 379 408 440 453 493 556Heat recovery capacity (3) kW 1114 1211 1260 1334 1494 1613 1676 1766 1903 1970 2123 2383COMPRESSORSNo. Compressors/No. Circuits N. 2/2 2/2 2/2 2/2 2/2 2/2 2/2 2/2 3/3 3/3 3/3 4/4NOISE LEVELSSound power (4) dB(A) 96 96 97 97 98 99 99 99 99 99 99 99Sound pressure (5) dB(A) 63 63 64 64 65 66 66 66 66 66 66 66SIZEA (6) mm 7000 7000 9400 9400 9400 9400 9400 11200 11200 11200 11200 11200B (6) mm 2260 2260 2260 2260 2260 2260 2260 2260 2260 2260 2260 2260H (6) mm 2430 2430 2430 2430 2430 2430 2430 2430 2430 2430 2430 2430Operating weight (6) kg 8550 8700 9530 9800 10210 * * * 12560 12690 12830 16110

FOCS / LNModels 1502 1702 1902 1922 1972 2022 2602 2652 2702 2712 2722 3152 3602COOLINGCooling capacity (1) kW 287 318 354 405 430 470 512 546 582 611 664 706 769Total power input (1) kW 101 120 134 14 159 163 186 197 210 219 228 268 291EER 2,84 2,65 2,64 28,9 2,70 2,88 2,75 2,77 2,77 2,79 2,91 2,63 2,64ESEER 4,02 3,81 3,87 4 3,96 4,03 3,81 3,95 4,04 4,02 4,17 3,96 4,01COOLING WITH PARTIAL RECOVERYCooling capacity (2) kW 298 330 367 420 446 488 531 566 604 634 689 733 798Total power input (2) kW 97,2 111 122 137 154 157 172 190 203 212 220 259 281Desuperheater heating capacity (2) kW 85,2 116 129 144 136 138 180 168 180 187 194 230 250COOLING WITH TOTAL RECOVERYCooling capacity (3) kW 301 349 381 425 450 481 547 581 625 651 703 767 826Total power input (3) kW 89,1 102 118 127 135 136 162 171 180 183 186 219 252Heat recovery capacity (3) kW 384 445 492 545 577 609 699 742 793 823 878 973 1063COMPRESSORSNo. Compressors/No. Circuits N. 2/2 2/2 2/2 2/2 2/2 2/2 2/2 2/2 2/2 2/2 2/2 2/2 2/2NOISE LEVELSSound power (4) dB(A) 92 92 93 93 93 93 93 93 93 95 95 95 95Sound pressure (5) dB(A) 60 60 61 61 61 61 61 61 61 63 63 63 63SIZEA (6) mm 4000 4000 4000 4900 4900 4900 4900 4900 4900 5800 5800 5800 5800B (6) mm 2260 2260 2260 2260 2260 2260 2260 2260 2260 2260 2260 2260 2260H (6) mm 2430 2430 2430 2430 2430 2430 2430 2430 2430 2430 2430 2430 2430Operating weight (6) kg 3800 3830 3920 4410 5090 5630 5630 5730 5840 6010 6340 7330 7900

Page 105: Products Guide V01 - ParagonEfficient project management thanks to Climaveneta as unique project leader. Complete and specialized Organization Climaveneta qualifies itself for the

103

Minimum clearance required1502-8404

Switchboard side mm 1800Switchboard opposite side mm 1500Condensation coil side mm 2000

Note:

1 Evaporator water (in/out) = 12/7°C; Condenser air (in) = 35°C.

2 Evaporator water (in/out) = 12/7°C; Condenser air (in) = 35°C; Desuperheater water (in/out) = 40/45°C.

3 Evaporator water (in/out) = 12/7°C; Recovery unit water (in/out) = 40/45°C

4 Sound power on the basis of measurements made in compliance with ISO 9614 and Eurovent 8/1 for Eurovent certified units; in compliance with ISO 3744 for non-certified units.

5 Average sound pressure level, at 10m distance, unit in a free field on a reflective surface; non-binding value obtained from the sound power level.

6 Unit in standard configuration/execution, without optional accessories

Models 3902 4202 4212 4222 4822 5702 6002 6022 6903 7203 7223 8404COOLINGCooling capacity (1) kW 768 822 909 975 1088 1150 1185 1279 1307 1358 1512 1590Total power input (1) kW 323 346 354 376 426 439 460 491 557 577 653 682EER 2,38 2,38 2,57 2,59 2,55 2,62 2,57 2,61 2,35 2,35 2,32 2,33ESEER 3,61 3,56 3,73 3,81 4,08 3,69 3,63 3,88 3,61 3,76 3,80 3,51COOLING WITH PARTIAL RECOVERYCooling capacity (2) kW 797 852 943 1011 1129 1194 1229 1327 1357 1410 1569 1650Total power input (2) kW 312 334 342 363 411 424 445 475 538 558 631 659Desuperheater heating capacity (2) kW 280 300 303 323 368 377 369 424 478 496 564 590COOLING WITH TOTAL RECOVERYCooling capacity (3) kW 868 949 993 1056 1180 1267 1320 1382 1490 1544 1659 1861Total power input (3) kW 262 279 284 295 334 368 379 408 440 453 493 556Heat recovery capacity (3) kW 1115 1211 1260 1334 1494 1613 1676 1766 1903 266 286 320COMPRESSORSNo. Compressors/No. Circuits N. 2/2 2/2 2/2 2/2 2/2 2/2 2/2 2/2 3/3 3/3 3/3 4/4NOISE LEVELSSound power (4) dB(A) 91 91 92 92 93 94 94 94 94 94 94 95Sound pressure (5) dB(A) 58 58 59 59 60 61 61 61 61 61 61 62SIZEA (6) mm 7000 7000 9400 9400 9400 11200 11200 11200 11200 11200 11200 11200B (6) mm 2260 2260 2260 2260 2260 2260 2260 2260 2260 2260 2260 2260H (6) mm 2430 2430 2430 2430 2430 2430 2430 2430 2430 2430 2430 2430Operating weight (6) kg 8640 8790 9620 9890 10300 * * * 12690 12830 12970 16290

FOCS / SLModels 1502 1702 1902 1922 1972 2022 2602 2652 2702 2712 2722 3152 3602COOLINGCooling capacity (1) kW 275 300 337 389 413 454 486 520 554 586 638 669 726Total power input (1) kW 105 127 140 159 171 174 197 208 223 234 247 290 312EER 2,62 2,36 2,41 2,45 2,42 2,61 2,47 2,50 2,48 2,50 2,58 2,31 2,33ESEER 3,85 3,58 3,70 3,83 3,78 3,87 3,60 3,75 3,82 3,84 3,96 3,70 3,73COOLING WITH PARTIAL RECOVERYCooling capacity (2) kW 285 311 349 404 429 471 504 539 575 608 662 694 753Total power input (2) kW 102 122 136 153 165 168 190 201 216 226 239 280 301Desuperheater heating capacity (2) kW 90,1 109 120 137 148 149 169 180 193 202 213 251 271COOLING WITH TOTAL RECOVERYCooling capacity (3) kW 301 349 381 425 450 481 547 581 625 651 703 767 826Total power input (3) kW 89,1 102 118 127 135 136 162 171 180 183 186 219 252Heat recovery capacity (3) kW 385 445 492 545 577 609 699 742 793 823 878 973 1063COMPRESSORSNo. Compressors/No. Circuits N. 2/2 2/2 2/2 2/2 2/2 2/2 2/2 2/2 2/2 2/2 2/2 2/2 2/2NOISE LEVELSSound power (4) dB(A) 87 87 88 88 88 89 89 89 89 90 90 90 90Sound pressure (5) dB(A) 55 55 56 56 56 57 57 57 57 58 58 58 58SIZEA (6) mm 4000 4000 4000 4900 4900 4900 4900 4900 4900 5800 5800 5800 5800B (6) mm 2260 2260 2260 2260 2260 2260 2260 2260 2260 2260 2260 2260 2260H (6) mm 2430 2430 2430 2430 2430 2430 2430 2430 2430 2430 2430 2430 2430Operating weight (6) kg 3850 3880 3970 4460 5170 5700 5700 5800 5920 6080 6410 7410 8000

A

B

H

Page 106: Products Guide V01 - ParagonEfficient project management thanks to Climaveneta as unique project leader. Complete and specialized Organization Climaveneta qualifies itself for the

104

Main accessoriesElectronic expansion valve

Soft start

Remote keyboard

Set-up for remote connectivity with ModBus, Echelon LonTalk, Trend, Bacnet protocol board.

Hydronic group

VPF (Variable Primary Flow) kit: variable flow pumps with on board regulation

FeaturesEXTREMELY SILENT OPERATION

As result of a sistematic design oriented to minimize the noise level, XL version´s units give the best compromise between silence and efficiency on the market.

ADAPTABILITY

Adaptability at the buildings cooling request thanks to the continuous capacity regulation, assured by sophisticated controls logic

EXTENSIVE RANGE OF OPERATION

Extensive range of operation: full load is granted up to 46°C and in partialization even over 50°C of external air temperature.

INTEGRATED HYDRONIC MODULE

It consists of 2 pumps, 4-pole motor, fixed or variable speed, with high or low head options to satisfy different industrial applications and demands for comfort.

VersionsXL extremely low noise version

CommandsW3000SE LargeThe W3000 SE Large controller offers advanced functions and algorithms. The keypad is generously sized with full operating status display. The commands and detailed LCD display make access to the units settings easy and safe. These resources allow to consult and intervene on the unit by means of a multi-level menu, with selectable language setting. The diagnostics includes a complete alarm management, with the “black-box” and alarm logging functions for enhanced analysis of the unit operation. For multiple units systems, the regulation of the resources, via optional proprietary devices, can be implemented. Energy metering, for both consumption and capacity, can also be developed. Supervision can be easily developed via proprietary devices or the integration in third party systems by means of the most common protocols as ModBus, Bacnet, Bacnet-over-IP, Echelon LonWorks. Compatibility with the remote keyboard managing up to 10 units. Availability of an internal real time clock for operation scheduling (4-day profiles with 10 hour belts). The regulation features the continuous modulation of capacity, based on a dynamic dead band and referring to the leaving water temperature. As alternative, step-wise regulation is also available, referred to the return water temperature with selectable proportional- or proportional-integral logic. As option (VPF package), the modulation of capacity is integrated with the modulation of the water flow, by means of inverter and dedicated resources for the hydraulic circuit.

Hydronic - chiller

FOCS-XL 1502÷6002

Chiller, air source for outdoor installation

272 - 1180 kWUnit DescriptionOutdoor unit for the production of chilled water with semi-hermetic screw compressors optimized for R134a, axial-flow fans, condensing coil with copper tubes and aluminium fins, shell and tubes evaporator designed by Climaveneta and thermostatic expansion valve. Base and supporting structure and panels are of galvanized epoxy powder coated steel with increased thickness. Flexible and reliable unit; it easily adapts itself to different thermal load conditions thanks to the precise thermoregulation. The high performances level is achieved thanks to the accurate sizing of all internal components.

Page 107: Products Guide V01 - ParagonEfficient project management thanks to Climaveneta as unique project leader. Complete and specialized Organization Climaveneta qualifies itself for the

105

Minimum clearance required1502-6002

Switchboard side mm 1800Switchboard opposite side mm 1500Condensation coil side mm 2000

Note:

1 Evaporator water (in/out) = 12/7°C; Condenser air (in) = 35°C.

2 Sound power on the basis of measurements made in compliance with ISO 9614 and Eurovent 8/1 for Eurovent certified units; in compliance with ISO 3744 for non-certified units.

3 Average sound pressure level, at 10m distance, unit in a free field on a reflective surface; non-binding value obtained from the sound power level.

4 Unit in standard configuration/execution, without optional accessories

FOCS-XL / XLModels 1502 1702 1902 2002 2402 2602 2702 3202 3602 4202 4802 5402 6002COOLINGCooling capacity (1) kW 272 310 348 391 456 488 550 645 737 861 952 1079 1180Total power input (1) kW 105 123 137 143 169 192 227 254 313 332 363 411 471EER 2,59 2,52 2,53 2,74 2,69 2,54 2,43 2,54 2,36 2,59 2,63 2,63 2,51ESEER 4,15 3,94 4,11 4,19 4,21 3,92 3,89 3,98 4,07 3,94 4,24 3,76 3,56COMPRESSORSNo. Compressors/No. Circuits N. 2 / 2 2 / 2 2 / 2 2 / 2 2 / 2 2 / 2 2 / 2 2 / 2 2 / 2 2 / 2 2 / 2 2 / 2 2 / 2NOISE LEVELSSound power (2) dB(A) 82 82 83 84 85 85 85 85 85 86 87 90 91Sound pressure (3) dB(A) 50 50 51 52 53 53 53 52 52 53 54 57 58SIZEA (4) mm 4900 4900 4900 5800 5800 5800 5800 7000 7000 9900 11700 11700 11700B (4) mm 2260 2260 2260 2260 2260 2260 2260 2260 2260 2260 2260 2260 2260H (4) mm 2500 2500 2500 2500 2500 2500 2500 2500 2500 2500 2500 2500 2500Operating weight (4) kg 4420 4450 4540 6020 6170 6230 6350 8000 8640 9710 10460 10720 10730

COOLING

r HFCR-134a

SCREWAXIALSHELL & TUBES

Page 108: Products Guide V01 - ParagonEfficient project management thanks to Climaveneta as unique project leader. Complete and specialized Organization Climaveneta qualifies itself for the

106

Main accessoriesSoft start

VPF (Variable Primary Flow) kit: variable flow pumps with on board regulation

Compressor power factor device

Electronic expansion valve

Variable speed condensation control (standard on /LN, /SL)

Remote keyboard (distance to 200m and to 500m)

Set-up for remote connectivity with ModBus, Echelon LonTalk, Bacnet protocol board

Hydronic group

FeaturesFLEXIBILITY

Flexibility in applications thanks to the many available configurations and versions

ADAPTABILITY

Adaptability at the buildings cooling request thanks to the continuous capacity regulation, assured by sophisticated controls logic

HIGH EFFICIENCY

Unit in Class A as per Eurovent. High efficiency for low energy consumption during the operating hours

EXTENSIVE RANGE OF OPERATION

Extensive range of operation with external air temperature up to 46°C at full load; with total heat recovery, hot water can be produced up to a temperature of 55°C.

INTEGRATED HYDRONIC MODULE

It consists of 2 pumps, 2 or 4-pole motor, fixed or variable speed, with high or low head options to satisfy different industrial applications and demands for comfort.

Configurations- base function

D partial condensing heat recovery function

R total condensing heat recovery function

VersionsB base version

LN low noise version

SL super-low noise version

CommandsW3000SE LargeThe W3000 SE Large controller offers advanced functions and algorithms. The keypad is generously sized with full operating status display. The commands and detailed LCD display make access to the units settings easy and safe. These resources allow to consult and intervene on the unit by means of a multi-level menu, with selectable language setting. The diagnostics includes a complete alarm management, with the “black-box” and alarm logging functions for enhanced analysis of the unit operation. For multiple units systems, the regulation of the resources, via optional proprietary devices, can be implemented. Energy metering, for both consumption and capacity, can also be developed. Supervision can be easily developed via proprietary devices or the integration in third party systems by means of the most common protocols as ModBus, Bacnet, Bacnet-over-IP, Echelon LonWorks. Compatibility with the remote keyboard managing up to 10 units. Availability of an internal real time clock for operation scheduling (4-day profiles with 10 hour belts). The regulation features the continuous modulation of capacity, based on a dynamic dead band and referring to the leaving water temperature. As alternative, step-wise regulation is also available, referred to the return water temperature with selectable proportional- or proportional-integral logic. As option (VPF package), the modulation of capacity is integrated with the modulation of the water flow, by means of inverter and dedicated resources for the hydraulic circuit.

Hydronic - chiller

FOCS-CA 1502÷5424

High efficiency chiller, air source for outdoor installation

310 - 1381 kWUnit DescriptionOutdoor unit for the production of chilled water with semi-hermetic screw compressors optimized for R134a, axial-flow fans, condensing coil with copper tubes and aluminium fins, shell and tubes evaporator designed by Climaveneta and thermostatic expansion valve. Base and supporting structure and panels are of galvanized epoxy powder coated steel with increased thickness. Flexible and reliable unit; it easily adapts itself to different thermal load conditions thanks to the precise thermoregulation. The high performances level is achieved thanks to the accurate sizing of all internal components.

Page 109: Products Guide V01 - ParagonEfficient project management thanks to Climaveneta as unique project leader. Complete and specialized Organization Climaveneta qualifies itself for the

107

Note:

1 Evaporator water (in/out) = 12/7°C; Condenser air (in) = 35°C.

2 Evaporator water (in/out) = 12/7°C; Condenser air (in) = 35°C; Desuperheater water (in/out) = 40/45°C.

3 Evaporator water (in/out) = 12/7°C; Recovery unit water (in/out) = 40/45°C

4 Sound power on the basis of measurements made in compliance with ISO 9614 and Eurovent 8/1 for Eurovent certified units; in compliance with ISO 3744 for non-certified units.

5 Average sound pressure level, at 10m distance, unit in a free field on a reflective surface; non-binding value obtained from the sound power level.

6 Unit in standard configuration/execution, without optional accessories

Models 3152 3602 3902 4202 4212 4802 4822 5403 5414 5424COOLINGCooling capacity (1) kW 780 849 924 963 1037 1088 1187 1261 1332 1381Total power input (1) kW 245 272 288 302 314 338 365 405 416 428EER 3,18 3,12 3,20 3,18 3,30 3,21 3,25 3,11 3,20 3,22ESEER 4,21 4,15 4,04 3,97 4,01 4,20 4,19 4,21 4,18 4,18COOLING WITH PARTIAL RECOVERYCooling capacity (2) kW 809 881 959 999 1076 1130 1232 1309 1382 1433Total power input (2) kW 237 263 280 294 304 329 353 389 402 415Desuperheater heating capacity (2) kW 200 225 232 245 249 272 295 327 340 352COOLING WITH TOTAL RECOVERYCooling capacity (3) kW 786 849 911 948 1008 1086 1179 1256 1353 1407Total power input (3) kW 213 246 257 271 284 305 334 368 357 361Heat recovery capacity (3) kW 987 1080 1152 1203 1275 1373 1494 1602 1688 1746COMPRESSORSNo. Compressors/No. Circuits N. 2/2 2/2 2/2 2/2 2/2 2/2 2/2 3/3 4/4 4/4NOISE LEVELSSound power (4) dB(A) 100 100 102 102 102 102 102 103 103 103Sound pressure (5) dB(A) 67 67 69 69 69 69 69 70 70 70SIZEA (6) mm 7000 7000 9400 9400 11200 11200 11200 11200 11200 11200B (6) mm 2260 2260 2260 2260 2260 2260 2260 2260 2260 2260H (6) mm 2430 2430 2430 2430 2430 2430 2430 2430 2430 2430Operating weight (6) kg 7860 8660 9690 9920 10440 10280 10710 12180 12790 12860

FOCS-CA / BModels 1502 1702 1902 1922 1972 2022 2602 2652 2702 2712 2722COOLINGCooling capacity (1) kW 310 358 406 441 468 493 558 593 641 666 691Total power input (1) kW 95,4 110 128 140 147 156 176 187 202 208 215EER 3,25 3,23 3,15 3,15 3,18 3,16 3,17 3,17 3,17 3,20 3,21ESEER 4,15 4,07 3,95 4 4,02 4,02 4,02 4,04 4,17 4,18 4,18COOLING WITH PARTIAL RECOVERYCooling capacity (2) kW 321 372 421 458 485 511 579 616 665 691 716Total power input (2) kW 92,3 107 125 135 143 151 170 181 195 201 208Desuperheater heating capacity (2) kW 77,4 88,3 103 112 119 127 144 152 164 170 176COOLING WITH TOTAL RECOVERYCooling capacity (3) kW 303 349 396 436 463 489 554 589 647 676 703Total power input (3) kW 86,6 99 115 124 132 136 158 166 176 178 181Heat recovery capacity (3) kW 385 442 504 552 586 617 702 745 813 844 873COMPRESSORSNo. Compressors/No. Circuits N. 2/2 2/2 2/2 2/2 2/2 2/2 2/2 2/2 2/2 2/2 2/2NOISE LEVELSSound power (4) dB(A) 97 97 98 98 98 98 98 99 99 99 99Sound pressure (5) dB(A) 65 65 66 66 66 66 66 67 67 67 67SIZEA (6) mm 4900 4900 4900 4900 4900 4900 5800 5800 5800 5800 5800B (6) mm 2260 2260 2260 2260 2260 2260 2260 2260 2260 2260 2260H (6) mm 2430 2430 2430 2430 2430 2430 2430 2430 2430 2430 2430Operating weight (6) kg 4170 4250 4590 4670 5340 5750 6060 6140 6340 6400 6430

COOLING

r HFCR-134a

SCREWAXIALSHELL & TUBESENERGY CLASS

Page 110: Products Guide V01 - ParagonEfficient project management thanks to Climaveneta as unique project leader. Complete and specialized Organization Climaveneta qualifies itself for the

108

Note:

1 Evaporator water (in/out) = 12/7°C; Condenser air (in) = 35°C.

2 Evaporator water (in/out) = 12/7°C; Condenser air (in) = 35°C; Desuperheater water (in/out) = 40/45°C.

3 Evaporator water (in/out) = 12/7°C; Recovery unit water (in/out) = 40/45°C

4 Sound power on the basis of measurements made in compliance with ISO 9614 and Eurovent 8/1 for Eurovent certified units; in compliance with ISO 3744 for non-certified units.

5 Average sound pressure level, at 10m distance, unit in a free field on a reflective surface; non-binding value obtained from the sound power level.

6 Unit in standard configuration/execution, without optional accessories

Models 3152 3602 3902 4202 4212 4802 4822 5403 5414 5424COOLINGCooling capacity (1) kW 764 825 904 941 1019 1061 1167 1240 1302 1353Total power input (1) kW 245 275 286 300 308 337 366 401 420 436EER 3,11 3 3,16 3,13 3,30 3,14 3,18 3,09 3,10 3,10ESEER 4,36 4,33 4,24 4,12 4,24 4,41 4,42 4,41 4,32 4,31COOLING WITH PARTIAL RECOVERYCooling capacity (2) kW 793 856 938 976 1055 1102 1211 1287 1350 1404Total power input (2) kW 238 266 276 291 311 327 355 388 406 422Desuperheater heating capacity (2) kW 209 235 240 253 269 284 309 340 357 371COOLING WITH TOTAL RECOVERYCooling capacity (3) kW 786 849 911 949 1007 1086 1180 1256 1353 1407Total power input (3) kW 214 246 257 271 306 305 334 368 357 361Heat recovery capacity (3) kW 987 1080 1152 1203 1294 1373 1494 1602 1688 1746COMPRESSORSNo. Compressors/No. Circuits N. 2/2 2/2 2/2 2/2 2/2 2/2 2/2 3/3 4/4 4/4NOISE LEVELSSound power (4) dB(A) 94 94 96 96 96 96 96 97 97 97Sound pressure (5) dB(A) 61 61 63 63 63 63 63 64 64 64SIZEA (6) mm 7000 7000 9790 9790 11200 11200 11200 11200 11200 11200B (6) mm 2260 2260 2260 2260 2260 2260 2260 2260 2260 2260H (6) mm 2430 2430 2430 2430 2430 2430 2430 2430 2430 2430Operating weight (6) kg 7940 8740 9790 10020 10580 10420 10850 12330 12930 13000

FOCS-CA / LNModels 1502 1702 1902 1922 1972 2022 2602 2652 2702 2712 2722COOLINGCooling capacity (1) kW 304 351 397 433 460 484 545 579 625 651 676Total power input (1) kW 94,1 109 126 138 146 157 175 186 202 210 218EER 3,23 3,22 3,13 3,12 3,13 3,08 3,11 3,10 3,09 3,10 3,10ESEER 4,35 4,28 4,19 4,24 4,24 4,19 4,15 4,20 4,32 4,32 4,32COOLING WITH PARTIAL RECOVERYCooling capacity (2) kW 315 364 412 449 477 502 566 601 648 675 702Total power input (2) kW 91,1 105 123 135 142 152 170 180 196 203 211Desuperheater heating capacity (2) kW 79,6 90,8 106 117 124 133 149 157 171 178 186COOLING WITH TOTAL RECOVERYCooling capacity (3) kW 303 349 396 436 463 489 554 589 647 677 703Total power input (3) kW 86,6 99 115 124 132 139 158 166 176 178 181Heat recovery capacity (3) kW 385 442 504 553 586 620 702 745 813 844 873COMPRESSORSNo. Compressors/No. Circuits N. 2/2 2/2 2/2 2/2 2/2 2/2 2/2 2/2 2/2 2/2 2/2NOISE LEVELSSound power (4) dB(A) 91 91 92 92 92 92 92 93 93 93 93Sound pressure (5) dB(A) 59 59 60 60 60 60 60 61 61 61 61SIZEA (6) mm 4900 4900 4900 4900 4900 4900 5800 5800 5800 5800 5800B (6) mm 2260 2260 2260 2260 2260 2260 2260 2260 2260 2260 2260H (6) mm 2430 2430 2430 2430 2430 2430 2430 2430 2430 2430 2430Operating weight (6) kg 4200 4290 4670 4740 5410 5820 6130 6210 6420 6470 6500

Page 111: Products Guide V01 - ParagonEfficient project management thanks to Climaveneta as unique project leader. Complete and specialized Organization Climaveneta qualifies itself for the

109

Minimum clearance required1502-5424

Switchboard side mm 1800Switchboard opposite side mm 1500Condensation coil side mm 2000

Note:

1 Evaporator water (in/out) = 12/7°C; Condenser air (in) = 35°C.

2 Evaporator water (in/out) = 12/7°C; Condenser air (in) = 35°C; Desuperheater water (in/out) = 40/45°C.

3 Evaporator water (in/out) = 12/7°C; Recovery unit water (in/out) = 40/45°C

4 Sound power on the basis of measurements made in compliance with ISO 9614 and Eurovent 8/1 for Eurovent certified units; in compliance with ISO 3744 for non-certified units.

5 Average sound pressure level, at 10m distance, unit in a free field on a reflective surface; non-binding value obtained from the sound power level.

6 Unit in standard configuration/execution, without optional accessories

Models 3152 3602 3902 4202 4212 4802 4822 5403 5414 5424COOLINGCooling capacity (1) kW 735 791 873 905 990 1022 1133 1192 1252 1306Total power input (1) kW 260 290 296 312 320 353 390 422 447 469EER 2,82 2,72 2,94 2,90 3,09 2,89 2,90 2,82 2,80 2,78ESEER 4,17 4,12 4,11 3,98 4,15 4,28 4,30 4,23 4,14 4,13COOLING WITH PARTIAL RECOVERYCooling capacity (2) kW 763 820 905 939 1023 1060 1176 1236 1299 1355Total power input (2) kW 252 281 287 302 326 342 377 408 432 454Desuperheater heating capacity (2) kW 224 251 253 267 286 301 334 362 384 404COOLING WITH TOTAL RECOVERYCooling capacity (3) kW 786 849 911 949 1007 1086 1180 1256 1353 1407Total power input (3) kW 214 246 257 271 306 305 334 368 357 361Heat recovery capacity (3) kW 987 1080 1152 1203 1294 1373 1494 1602 1688 1746COMPRESSORSNo. Compressors/No. Circuits N. 2/2 2/2 2/2 2/2 2/2 2/2 2/2 3/3 4/4 4/4NOISE LEVELSSound power (4) dB(A) 90 90 91 91 92 93 93 94 94 94Sound pressure (5) dB(A) 57 57 58 58 59 60 60 61 61 61SIZEA (6) mm 7000 7000 9400 9400 11200 11200 11200 11200 11200 11200B (6) mm 2260 2260 2260 2260 2260 2260 2260 2260 2260 2260H (6) mm 2430 2430 2430 2430 2430 2430 2430 2430 2430 2430Operating weight (6) kg 8020 8830 9880 10110 10670 10510 10940 12460 13070 13140

FOCS-CA / SLModels 1502 1702 1902 1922 1972 2022 2602 2652 2702 2712 2722COOLINGCooling capacity (1) kW 294 340 383 420 447 470 523 557 599 626 653Total power input (1) kW 97,7 111 131 145 155 167 184 194 213 222 234EER 3,01 3,04 2,92 2,88 2,88 2,80 2,84 2,86 2,81 2,81 2,78ESEER 4,23 4,17 4,10 4,14 4,14 4,05 3,97 4,05 4,14 4,14 4,13COOLING WITH PARTIAL RECOVERYCooling capacity (2) kW 305 352 397 436 464 488 542 578 621 649 678Total power input (2) kW 94,3 108 127 141 150 162 177 188 206 216 227Desuperheater heating capacity (2) kW 83,4 95 111 124 132 143 158 167 183 192 202COOLING WITH TOTAL RECOVERYCooling capacity (3) kW 303 349 396 436 463 489 554 589 647 677 703Total power input (3) kW 86,6 99 115 124 132 139 158 166 176 178 181Heat recovery capacity (3) kW 385 442 504 553 586 620 702 745 813 844 873COMPRESSORSNo. Compressors/No. Circuits N. 2/2 2/2 2/2 2/2 2/2 2/2 2/2 2/2 2/2 2/2 2/2NOISE LEVELSSound power (4) dB(A) 87 87 88 88 88 89 89 89 89 90 90Sound pressure (5) dB(A) 55 55 56 56 56 57 57 57 57 58 58SIZEA (6) mm 4900 4900 4900 4900 4900 4900 5800 5800 5800 5800 5800B (6) mm 2260 2260 2260 2260 2260 2260 2260 2260 2260 2260 2260H (6) mm 2430 2430 2430 2430 2430 2430 2430 2430 2430 2430 2430Operating weight (6) kg 4250 4350 4720 4790 5480 5900 6200 6280 6490 6540 6570

A

B

H

Page 112: Products Guide V01 - ParagonEfficient project management thanks to Climaveneta as unique project leader. Complete and specialized Organization Climaveneta qualifies itself for the

110

Main accessoriesSet-up for remote connectivity with ModBus, Echelon LonTalk, Trend, Bacnet protocol board.

Remote keyboard (distance to 200m and to 500m)

VPF (Variable Primary Flow) kit: variable flow pumps with on board regulation

FeaturesSYSTEM EFFICIENCY

The unit is designed as a system: all components, with very high operating efficiency, are synergically regulated using proprietary controls logic, and the unit-system is perfectly integrated with all other Climaveneta units

VERY HIGH EFFICIENCY AT PARTIAL LOAD

Very high efficiency at partial load thanks to the inverter technology applied on screw compressors. Therefore, operating costs are reduced to a minimum

TRUE SILENCE

Silence optimized for the most frequent operational conditions, thanks to the accurate structures design, to the use of EC fans (DC brushless) and to the adoption of variable-speed driven compressors

HARMONY BETWEEN UNIT AND PLANT

Low inrush current and cos(phi) higher than 0.9, permit an easy electrical installation which is not stressed during start-up and with no need of extra devices for power factor correction. The use of inverter allows the unit partialize down to 15%, with consequent lower fluctuations of leaving water temperature

VersionsE high efficiency version

SL-E super-low noise, high efficiency version

CommandsW3000SE LargeThe W3000 SE Large controller offers advanced functions and algorithms. The keypad is generously sized with full operating status display. The commands and detailed LCD display make access to the units settings easy and safe. These resources allow to consult and intervene on the unit by means of a multi-level menu, with selectable language setting. The diagnostics includes a complete alarm management, with the “black-box” and alarm logging functions for enhanced analysis of the unit operation. For multiple units systems, the regulation of the resources, via optional proprietary devices, can be implemented. Energy metering, for both consumption and capacity, can also be developed. Supervision can be easily developed via proprietary devices or the integration in third party systems by means of the most common protocols as ModBus, Bacnet, Bacnet-over-IP, Echelon LonWorks. Compatibility with the remote keyboard managing up to 10 units. Availability of an internal real time clock for operation scheduling (4-day profiles with 10 hour belts). The regulation features the continuous modulation of capacity by adjustment of the compressor speed. The modulation is based on PID algorithms and referring to the leaving water temperature. This is combined with the management of the compressors status, with two selectable logics (proportional referred to the return temperature or dead band referred to the leaving temperature). As option (VPF package), the modulation of capacity is integrated with the modulation of the water flow, by means of inverter and dedicated resources for the hydraulic circuit.

Hydronic - chiller

i-FOCS 0052÷0082

High efficiency chiller, air source for outdoor installation

511 - 842 kWUnit DescriptionOutdoor unit for the production of chilled water with inverter driven screw compressors optimized for R134a, axial-flow fans, condensing coil with copper tubes and aluminium fins, shell and tube evaporator designed by Climaveneta and electronic expansion valve. Base and supporting structure and panels are of galvanized epoxy powder coated steel with increased thickness. Flexible and reliable unit; it easily adapts itself to different thermal load conditions thanks to the precise thermoregulation together with the use of inverter technology. The high performances level, especially at partial load, is achieved thanks to the accurate units design and to the use of innovative inverter motors in all key components of the unit (compressors, fans and pumps).

Page 113: Products Guide V01 - ParagonEfficient project management thanks to Climaveneta as unique project leader. Complete and specialized Organization Climaveneta qualifies itself for the

111

Minimum clearance required0052-0082

Switchboard side mm 1800Switchboard opposite side mm 1500Condensation coil side mm 2000

Note:

1 Evaporator water (in/out): 15/7°C; Condenser Air (in): 35C°

2 Sound power on the basis of measurements made in compliance with ISO 9614 and Eurovent 8/1 for Eurovent certified units; in compliance with ISO 3744 for non-certified units.

3 Average sound pressure level, at 10m distance, unit in a free field on a reflective surface; non-binding value obtained from the sound power level.

4 Unit in standard configuration/execution, without optional accessories

i-FOCS / SL-EModels 0052 0062 0072 0082COOLINGCooling capacity (1) kW 492 644 712 808Total power input (1) kW 204 267 298 343EER * * * *ESEER 4,70 4,71 4,76 4,72COMPRESSORSNo. Compressors/No. Circuits N. 2/2 2/2 2/2 2/2NOISE LEVELSSound power (2) dB(A) 91 92 92 93Sound pressure (3) dB(A) 59 60 59 60SIZEA (4) mm 4900 5800 7000 7000B (4) mm 2260 2260 2260 2260H (4) mm 2430 2430 2430 2430Operating weight (4) kg 6090 7290 8200 8690

Note:

1 Evaporator water (in/out): 15/7°C; Condenser Air (in): 35C°

2 Sound power on the basis of measurements made in compliance with ISO 9614 and Eurovent 8/1 for Eurovent certified units; in compliance with ISO 3744 for non-certified units.

3 Average sound pressure level, at 10m distance, unit in a free field on a reflective surface; non-binding value obtained from the sound power level.

4 Unit in standard configuration/execution, without optional accessories

i-FOCS / EModels 0052 0062 0072 0082COOLINGCooling capacity (1) kW 511 670 737 842Total power input (1) kW 203 263 294 335EER * * * *ESEER 4,69 4,70 4,74 4,71COMPRESSORSNo. Compressors/No. Circuits N. 2/2 2/2 2/2 2/2NOISE LEVELSSound power (2) dB(A) 97 98 98 99Sound pressure (3) dB(A) 65 66 65 66SIZEA (4) mm 4900 5800 7000 7000B (4) mm 2260 2260 2260 2260H (4) mm 2430 2430 2430 2430Operating weight (4) kg 5980 7190 8090 8580

COOLING

r HFCR-134a

SCREWEC FANSHELL & TUBES

Page 114: Products Guide V01 - ParagonEfficient project management thanks to Climaveneta as unique project leader. Complete and specialized Organization Climaveneta qualifies itself for the

112

Main accessoriesVPF (Variable Primary Flow) kit: variable flow pumps with on board regulation

Hydronic group

EC fans with electronic DC brushless motor

Set-up for remote connectivity with ModBus/Echelon/Bacnet protocol cards

FeaturesVERY HIGH EFFICIENCY

Very high efficiency at full and partial load, to top market levels, thanks to adopted technological solutions: large capacity modulation and expanded exchanger, offering minimum running costs of the unit in real working conditions.

VERSION ´CA-E´ AVAILABLE

The version ´CA-E´ is characterized by efficiency beyond the ´Class A´ for Eurovent. The technological choices adopted assure the minimization of operating costs and therefore a quick payback time.

EXTREMELY SILENT OPERATION

As result of a sistematic design oriented to minimize the noise level, XL version´s units give the best compromise between silence and efficiency on the market.

LOW INRUSH CURRENTS

Reduced breakaway starting currents thanks to the revolutionary centrifugal compressor

Configurations- base function

D partial condensing heat recovery function

Versions

SL-CA Super Low noise version, Class A of efficiency

XL-CA eXtra Low noise version, Class A of efficiency

SL-CA-E Super Low noise version, very high efficiency, Class A enhanced

CommandsW3000 largeThe controller W3000 large offers the latest control and functions specially developed for these units. The keypad is generously sized with full operating status display. The controls and detailed LCD make access to machine settings easy and safe. These resources permit to diirectly act on the unit settings through a multilevel menu, available in several languages. The diagnostics includes full management of alarms with black-box functions and alarm record for better analysis of unit performance. For multi-units plants a special device to coordinate and manage all the resources is available as an option; energy metering device is even possible as an option. Supervision is easy through Climaveneta devices or with various options for interfacing to ModBus, Bacnet, Echelon LonTalk protocols. Compatibility with remote keyboard (management up to 10 units). Clock available with programming of operation (standard 4 days and 10 time bands). Temperature regulation features the continuous capacity modulation, based on PID algorithms referring to water leaving temperature. This is combined with the compressors´ on/off management with a proportional logic on the return water temperature. As option is possible to choose the VPF system control integrated on-board to the units.

Hydronic - chiller

TECS2 Vision 2.0 0211÷1154

High efficiency chiller, air source for outdoor installation

220 - 1325 kWUnit DescriptionOutdoor unit for the production of chilled water featuring oil-free centrifugal compressor, with R134a, axial-flow fans, condensing coil with copper tubes and aluminium fins, shell and tube flooded evaporator and electronic regulation valve. Base and supporting structure and panels are of galvanized epoxy powder coated steel with increased thickness. Flexible and reliable unit; it easily adapts itself to different thermal load conditions thanks to the precise thermoregulation together with the use of inverter technology. The compressor is radically innovative: magnetic bearings and digital rotor speed control allow partial load efficiency levels to be reached that were hither to impossible.

Page 115: Products Guide V01 - ParagonEfficient project management thanks to Climaveneta as unique project leader. Complete and specialized Organization Climaveneta qualifies itself for the

113

Minimum clearance required0211-1154

Switchboard side mm 1800Switchboard opposite side mm 1500Condensation coil side mm 2000

Note:

1 Evaporator water (in/out) = 12/7°C; Condenser air (in) = 35°C.

2 Sound power on the basis of measurements made in compliance with ISO 9614 and Eurovent 8/1 for Eurovent certified units; in compliance with ISO 3744 for non-certified units.

3 Average sound pressure level, at 10m distance, unit in a free field on a reflective surface; non-binding value obtained from the sound power level.

4 Unit in standard configuration/execution, without optional accessories

TECS2 Vision 2.0 / SL-CA-EModels 0211 0351 0521 0452 0512 0552 0652 0712 0853 0913 1013 1054 1154COOLINGCooling capacity (1) kW 229 384 285 455 527 590 703 796 902 969 1086 1177 1324Total power input (1) kW 67,1 113 81,4 134 154 169 204 233 269 278 317 336 383EER 3,41 3,40 3,50 3,41 3,41 3,50 3,45 3,41 3,35 3,48 3,42 3,50 3,46ESEER 5,29 5,43 5,52 5,79 5,71 5,64 5,77 5,77 5,62 5,79 5,71 5,87 5,75COMPRESSORSNo. Compressors/No. Circuits N. 1 / 1 1 / 1 1 / 1 2 / 1 2 / 1 2 / 1 2 / 1 2 / 1 3 / 2 3 / 2 3 / 2 4 / 2 4 / 2NOISE LEVELSSound power (2) dB(A) 88 90 88 90 90 91 92 92 93 93 93 94 95Sound pressure (3) dB(A) 56 58 56 58 58 59 60 60 61 61 61 62 63SIZEA (4) mm 3100 4000 3100 4900 4900 5800 7000 7900 8500 9700 10600 11200 12400B (4) mm 2260 2260 2260 2260 2260 2260 2260 2260 2260 2260 2260 2260 2260H (4) mm 2430 2430 2430 2430 2430 2430 2430 2430 2430 2430 2430 2430 2430Operating weight (4) kg * * * * * * * * * * * * *

Note:

1 Evaporator water (in/out) = 12/7°C; Condenser air (in) = 35°C.

2 Sound power on the basis of measurements made in compliance with ISO 9614 and Eurovent 8/1 for Eurovent certified units; in compliance with ISO 3744 for non-certified units.

3 Average sound pressure level, at 10m distance, unit in a free field on a reflective surface; non-binding value obtained from the sound power level.

4 Unit in standard configuration/execution, without optional accessories

TECS2 Vision 2.0 / XL-CAModels 0211 0351 0521 0452 0512 0552 0652 0712 0853 0913 1013 1054 1154COOLINGCooling capacity (1) kW 220 341 254 435 526 579 640 739 874 900 972 1049 1174Total power input (1) kW 68,5 109 79,8 136 166 173 206 226 279 290 312 331 377EER 3,21 3,12 3,19 3,19 3,17 3,35 3,11 3,27 3,13 3,11 3,12 3,17 3,11ESEER 4,75 4,84 4,99 5,19 5,23 5,17 5,19 5,24 5,24 5,30 5,24 5,19 5,23COMPRESSORSNo. Compressors/No. Circuits N. 1 / 1 1 / 1 1 / 1 2 / 1 2 / 1 2 / 1 2 / 1 2 / 1 3 / 2 3 / 2 3 / 2 4 / 2 4 / 2NOISE LEVELSSound power (2) dB(A) 82 83 82 83 84 85 85 86 86 86 87 87 88Sound pressure (3) dB(A) 50 51 50 51 52 53 53 54 54 54 55 55 56SIZEA (4) mm 3100 4000 3100 4900 5800 7000 7000 7900 9400 9700 10600 11200 12400B (4) mm 2260 2260 2260 2260 2260 2260 2260 2260 2260 2260 2260 2260 2260H (4) mm 2430 2430 2430 2430 2430 2430 2430 2430 2430 2430 2430 2430 2430Operating weight (4) kg * * * * * * * * * * * * *

Note:

1 Evaporator water (in/out) = 12/7°C; Condenser air (in) = 35°C.

2 Sound power on the basis of measurements made in compliance with ISO 9614 and Eurovent 8/1 for Eurovent certified units; in compliance with ISO 3744 for non-certified units.

3 Average sound pressure level, at 10m distance, unit in a free field on a reflective surface; non-binding value obtained from the sound power level.

4 Unit in standard configuration/execution, without optional accessories

TECS2 Vision 2.0 / SL-CAModels 0211 0351 0521 0452 0512 0552 0652 0712 0853 0913 1013 1054 1154COOLINGCooling capacity (1) kW 233 346 258 442 509 574 650 742 848 904 977 1065 1183Total power input (1) kW 70,2 110 81,1 138 161 174 208 225 269 286 310 336 374EER 3,31 3,13 3,18 3,20 3,16 3,30 3,13 3,30 3,15 3,15 3,15 3,17 3,17ESEER 4,77 4,72 4,87 5,07 5,17 5,09 5,04 5,16 5,12 5,13 5,09 5,06 5,14COMPRESSORSNo. Compressors/No. Circuits N. 1 / 1 1 / 1 1 / 1 2 / 1 2 / 1 2 / 1 2 / 1 2 / 1 3 / 2 3 / 2 3 / 2 4 / 2 4 / 2NOISE LEVELSSound power (2) dB(A) 88 90 88 90 90 91 92 92 93 93 93 94 94Sound pressure (3) dB(A) 56 58 56 58 58 59 60 60 61 61 61 62 62SIZEA (4) mm 3100 4000 3100 4900 4900 5800 7000 7000 8500 9700 10600 11200 11500B (4) mm 2260 2260 2260 2260 2260 2260 2260 2260 2260 2260 2260 2260 2260H (4) mm 2430 2430 2430 2430 2430 2430 2430 2430 2430 2430 2430 2430 2430Operating weight (4) kg * * * * * * * * * * * * *

COOLING

r HFCR-134a

CENTRIFUGALAXIALSHELL & TUBESENERGY CLASS

Page 116: Products Guide V01 - ParagonEfficient project management thanks to Climaveneta as unique project leader. Complete and specialized Organization Climaveneta qualifies itself for the

114

Main accessoriesRemote keyboard (distance to 200m and to 500m)

Coils with FIN GUARD SILVER treatment

Automatic circuit breakers on loads

Modulating valve for water temperature control in Free-Cooling mode

FeaturesOUTSTANDING VERSATILITY

The NECS FC units are available in two separate versions: B (basic), SL (super low noise) in order to fully satisfy special requirements and cope with the most complex installation solutions in both the Industrial Process and the Comfort sectors.

ELEVATED ENERGY EFFICIENCY

Thanks to the dedicated coils for Free-Cooling, the R-410A optimised scroll compressors and the R-410A refrigerant, the NECS FC units allow an average power saving of 30% compared with standard European consumption.

MAXIMUM FLEXIBILITY

Flexibility is achieved by the continuous modulation of the capacity provided by the compressors. The three-way modulating valve (optional) on the water side offers improved leaving water temperature control also at low outdoor temperatures.

CUSTOMISED CONTROL

Customised adjustment constantly guarantees the required temperature of the chilled water whilst fully exploiting all the available resources (compressors, fans and water coils) in relation to the temperature of the external air. This makes it possible to fully use the free-cooling system even when external air temperatures are close to zero.

INTEGRATED HYDRONIC MODULE

It consists of 1 or 2 pumps with 2 or 4-pole motor, with three head options to satisfy different industrial applications and demands for comfort

Configurations- base function

NG function for free-cooling without use of glycole

VersionsB base version

SL super-low noise version

CommandsW3000SE LargeThe W3000 SE Large controller offers advanced functions and algorithms. The keypad is generously sized with full operating status display. The commands and detailed LCD display make access to the units settings easy and safe. These resources allow to consult and intervene on the unit by means of a multi-level menu, with selectable language setting. The diagnostics includes a complete alarm management, with the “black-box” and alarm logging functions for enhanced analysis of the unit operation. For multiple units systems, the regulation of the resources, via optional proprietary devices, can be implemented. Energy metering, for both consumption and capacity, can also be developed. Supervision can be easily developed via proprietary devices or the integration in third party systems by means of the most common protocols as ModBus, Bacnet, Bacnet-over-IP, Echelon LonWorks. Compatibility with the remote keyboard managing up to 10 units. Availability of an internal real time clock for operation scheduling (4-day profiles with 10 hour belts). The regulation features a step-wise regulation, referred to the return water temperature with selectable proportional- or proportional-integral logic.

Hydronic - chiller

NECS-FC 0152÷1204

Chiller, air source with free-cooling

41,5 - 377 kWUnit DescriptionExternal units for the production of chilled water, with Free-Cooling function, fitted with hermetic Scroll compressors, axial fans, braze-welded plate exchanger and thermostat expansion valve in R410A. External panelling in peraluman and base in painted galvanised steel. NECS Free-Cooling, a must when demand is high throughout the year, also during the cold season, therefore. In fact, the greater the difference between the temperature of the chilled water and the temperature of the external air, the greater the advantage of free-cooling.

Page 117: Products Guide V01 - ParagonEfficient project management thanks to Climaveneta as unique project leader. Complete and specialized Organization Climaveneta qualifies itself for the

115

NECS-FC / BModels 0152 0182 0202 0252 0302 0352 0412 0452 0512NECS-FCFREE-COOLING OFFCooling capacity (1) kW 43,6 51 61,9 68 88,5 104 115 131 149Total power input (1) kW 14,1 15,5 19,5 22,5 28,3 30,9 35,8 41,1 43,8EER 3,09 3,29 3,17 3,02 3,13 3,37 3,21 3,19 3,40FREE-COOLING ON 100%Cooling capacity (2) kW 43,3 51 61,9 68 88,5 104 115 131 149Total power input (2) kW 1,50 1,50 4,20 4,20 4,20 4,20 4,20 6,30 6,30Total Free-Cooling temperature (2) °C 1,40 1,10 0,80 0 -0,80 0,40 -0,70 -0,40 0,20COMPRESSORSNo. Compressors/No. Circuits N. 2/1 2/1 2/1 2/1 2/1 2/1 2/1 2/1 2/1NOISE LEVELSSound power (3) dB(A) 87 87 90 90 91 91 92 92 93Sound pressure (4) dB(A) 55 55 58 58 59 59 60 60 61SIZEA (5) mm 2200 2200 2602 2602 2602 3602 3602 3602 4602B (5) mm 920 920 1104 1104 1104 1104 1104 1104 1104H (5) mm 1780 1780 2175 2175 2175 2175 2175 2175 2205Operating weight (5) kg 670 710 870 880 1060 1310 1340 1410 1650NECS-FC-NGFREE-COOLING OFFCooling capacity (1) kW 44,8 52,4 63,6 69,8 90,9 107 118 135 153Total power input (1) kW 14,1 15,5 19,5 22,5 28,3 30,9 35,8 41,1 43,8EER 3,18 3,38 3,26 3,10 3,21 3,46 3,30 3,28 3,49FREE-COOLING ON 100%Cooling capacity (2) kW 44,8 54,4 63,6 69,8 90,9 107 118 135 153Total power input (2) kW 1,50 1,50 4,20 4,20 4,20 4,20 4,20 6,30 6,30Total Free-Cooling temperature (2) °C -1,60 -1,90 -2,20 -3 -3,80 -2,60 -3,70 -3,40 -2,80COMPRESSORSNo. Compressors/No. Circuits N. 2/1 2/1 2/1 2/1 2/1 2/1 2/1 2/1 2/1NOISE LEVELSSound power (3) dB(A) 87 87 90 90 91 91 92 92 93Sound pressure (4) dB(A) 55 55 58 58 59 59 60 60 61SIZEA (5) mm 2200 2200 2602 2602 2602 3602 3602 3602 4602B (5) mm 920 920 1104 1104 1104 1104 1104 1104 1104H (5) mm 1780 1780 2175 2175 2175 2175 2175 2175 2205Operating weight (5) kg 710 760 920 940 1130 1410 1450 1530 1780

COOLINGFREE COOLING

r HFCR-410A

SCROLLAXIALPLATES

Note:

1 Evaporator water (in/out): 15/10°C; Condenser air (in): 30°C; Ethylene glycol: 30% (not applicable to NG configurations).

2 Evaporator water (in/out): 15/10°C; Ethylene glycol: 30 % (not applicable to NG configurations).

3 Sound power on the basis of measurements made in compliance with ISO 9614 and Eurovent 8/1 for Eurovent certified units; in compliance with ISO 3744 for non-certified units.

4 Average sound pressure level, at 10m distance, unit in a free field on a reflective surface; non-binding value obtained from the sound power level.

5 Unit in standard configuration/execution, without optional accessories

Page 118: Products Guide V01 - ParagonEfficient project management thanks to Climaveneta as unique project leader. Complete and specialized Organization Climaveneta qualifies itself for the

116

Note:

1 Evaporator water (in/out): 15/10°C; Condenser air (in): 30°C; Ethylene glycol: 30% (not applicable to NG configurations).

2 Evaporator water (in/out): 15/10°C; Ethylene glycol: 30 % (not applicable to NG configurations).

3 Sound power on the basis of measurements made in compliance with ISO 9614 and Eurovent 8/1 for Eurovent certified units; in compliance with ISO 3744 for non-certified units.

4 Average sound pressure level, at 10m distance, unit in a free field on a reflective surface; non-binding value obtained from the sound power level.

5 Unit in standard configuration/execution, without optional accessories

Models 0552 0612 0604 0704 0804 0904 1004 1104 1204NECS-FCFREE-COOLING OFFCooling capacity (1) kW 166 187 177 207 234 268 293 336 377Total power input (1) kW 51,5 59,8 56,4 62,5 73,8 79,9 89,6 102 118EER 3,23 3,12 3,14 3,31 3,17 3,35 3,27 3,31 3,19FREE-COOLING ON 100%Cooling capacity (2) kW 166 187 177 207 234 268 293 336 377Total power input (2) kW 6,30 8,40 8,40 8,40 12,6 12,6 12,6 12,6 16,8Total Free-Cooling temperature (2) °C -1,10 -1,10 1,60 -0,10 0,30 1,40 0,60 0,50 0,40COMPRESSORSNo. Compressors/No. Circuits N. 2/1 2/1 4/2 4/2 4/2 4/2 4/2 4/2 4/2NOISE LEVELSSound power (3) dB(A) 93 94 93 93 94 94 94 95 96Sound pressure (4) dB(A) 61 62 61 61 62 62 62 63 64SIZEA (5) mm 4602 4602 4110 4110 4110 5110 5110 5110 5110B (5) mm 1104 1104 2220 2220 2220 2220 2220 2220 2220H (5) mm 2205 2205 2150 2150 2150 2150 2150 2430 2430Operating weight (5) kg 1680 1740 2200 2330 2510 2880 2940 3260 3400NECS-FC-NGFREE-COOLING OFFCooling capacity (1) kW 171 192 182 212 241 275 301 345 387Total power input (1) kW 51,5 59,8 56,4 62,5 73,8 79,9 89,6 102 118EER 3,32 3,21 3,23 3,40 3,26 3,44 3,36 3,40 3,28FREE-COOLING ON 100%Cooling capacity (2) kW 171 192 182 212 241 279 301 345 387Total power input (2) kW 6,30 8,40 8,40 8,40 12,6 12,6 12,6 12,6 16,8Total Free-Cooling temperature (2) °C -4,10 -4,10 -1,40 -3,10 -2,70 -1,30 -2,40 -2,50 -2,60COMPRESSORSNo. Compressors/No. Circuits N. 2/1 2/1 4/2 4/2 4/2 4/2 4/2 4/2 4/2NOISE LEVELSSound power (3) dB(A) 93 94 93 93 94 94 94 95 96Sound pressure (4) dB(A) 61 62 61 61 62 62 62 63 64SIZEA (5) mm 4602 4602 4110 4110 4110 5110 5110 5110 5110B (5) mm 1104 1104 2220 2220 2220 2220 2220 2220 2220H (5) mm 2205 2205 2150 2150 2150 2150 2150 2430 2430Operating weight (5) kg 1810 1890 2510 2650 2840 3250 3320 3700 3850

Page 119: Products Guide V01 - ParagonEfficient project management thanks to Climaveneta as unique project leader. Complete and specialized Organization Climaveneta qualifies itself for the

117

NECS-FC / SLModels 0152 0182 0202 0252 0302 0352 0412 0452 0512NECS-FCFREE-COOLING OFFCooling capacity (1) kW 41,5 49,8 56,9 63,8 82,4 97,9 112 122 137Total power input (1) kW 14,3 16,1 19,1 21,8 28 32,3 35,7 41,3 45,8EER 2,90 3,09 2,98 2,93 2,94 3,03 3,13 2,96 3FREE-COOLING ON 100%Cooling capacity (2) kW 41,5 49,8 56,9 63,8 82,4 97,9 112 122 137Total power input (2) kW 0,60 1,50 1,50 1,70 1,70 2,60 2,60 2,60 3,50Total Free-Cooling temperature (2) °C -1,20 -1,50 -1,10 -1,30 -1,30 -1,20 -0,70 -1,50 -1,60COMPRESSORSNo. Compressors/No. Circuits N. 2/1 2/1 2/1 2/1 2/1 2/1 2/1 2/1 2/1NOISE LEVELSSound power (3) dB(A) 77 78 78 79 80 81 81 82 83Sound pressure (4) dB(A) 45 46 46 47 48 49 49 50 51SIZEA (5) mm 2200 2602 2602 2602 3602 3602 4602 4602 4602B (5) mm 920 1104 1104 1104 1104 1104 1104 1104 1104H (5) mm 1780 2175 2175 2175 2175 2175 2205 2205 2205Operating weight (5) kg 680 860 920 940 1240 1350 1590 1610 1690NECS-FC-NGFREE-COOLING OFFCooling capacity (1) kW 42,6 51,2 58,4 65,6 86,5 101 115 126 141Total power input (1) kW 14,3 16,1 19,1 21,8 28 32,3 35,7 41,3 45,8EER 2,98 3,18 3,06 3,01 3,09 3,11 3,22 3,04 3,08FREE-COOLING ON 100%Cooling capacity (2) kW 42,6 51,2 58,4 65,6 86,5 101 115 126 141Total power input (2) kW 0,60 1,50 1,50 1,70 1,70 2,60 2,60 2,60 3,40Total Free-Cooling temperature (2) °C -4,20 -4,50 -4,10 -4,30 -4,30 -4,20 -3,70 -4,50 -4,60COMPRESSORSNo. Compressors/No. Circuits N. 2/1 2/1 2/1 2/1 2/1 2/1 2/1 2/1 2/1NOISE LEVELSSound power (3) dB(A) 77 78 78 79 80 81 81 82 83Sound pressure (4) dB(A) 46 47 47 48 49 50 50 51 52SIZEA (5) mm 2200 2602 2602 2602 3602 3602 4602 4602 4602B (5) mm 920 1104 1104 1104 1104 1104 1104 1104 1104H (5) mm 1780 2175 2175 2175 2175 2175 2205 2205 2205Operating weight (5) kg 730 910 970 990 1300 1450 1690 1730 1810

Note:

1 Evaporator water (in/out): 15/10°C; Condenser air (in): 30°C; Ethylene glycol: 30% (not applicable to NG configurations).

2 Evaporator water (in/out): 15/10°C; Ethylene glycol: 30 % (not applicable to NG configurations).

3 Sound power on the basis of measurements made in compliance with ISO 9614 and Eurovent 8/1 for Eurovent certified units; in compliance with ISO 3744 for non-certified units.

4 Average sound pressure level, at 10m distance, unit in a free field on a reflective surface; non-binding value obtained from the sound power level.

5 Unit in standard configuration/execution, without optional accessories

Page 120: Products Guide V01 - ParagonEfficient project management thanks to Climaveneta as unique project leader. Complete and specialized Organization Climaveneta qualifies itself for the

118

Minimum clearance required0152-0612 0604-1204

Switchboard side mm 800 1100Switchboard opposite side mm 800 1100Condensation coil side mm 1500 2000Opposite side of cond. coil mm 800 2000

Note:

1 Evaporator water (in/out): 15/10°C; Condenser air (in): 30°C; Ethylene glycol: 30% (not applicable to NG configurations).

2 Evaporator water (in/out): 15/10°C; Ethylene glycol: 30 % (not applicable to NG configurations).

3 Sound power on the basis of measurements made in compliance with ISO 9614 and Eurovent 8/1 for Eurovent certified units; in compliance with ISO 3744 for non-certified units.

4 Average sound pressure level, at 10m distance, unit in a free field on a reflective surface; non-binding value obtained from the sound power level.

5 Unit in standard configuration/execution, without optional accessories

Models 0552 0612 0604 0704 0804 0904 1004 1104 1204NECS-FCFREE-COOLING OFFCooling capacity (1) kW 156 179 166 193 216 243 274 313 351Total power input (1) kW 53,3 59,2 57,2 66,2 75,2 83,5 90,3 104 120EER 2,92 3,03 2,91 2,91 2,87 2,91 3,03 3,01 2,93FREE-COOLING ON 100%Cooling capacity (2) kW 156 179 166 193 216 243 274 313 351Total power input (2) kW 3,50 4,40 3,50 5,20 5,20 5,20 5,20 5,20 6,90Total Free-Cooling temperature (2) °C -1,70 -2,80 -1,60 -1,70 -3,30 -1,60 -2,80 -3 -2,90COMPRESSORSNo. Compressors/No. Circuits N. 2/1 2/1 4/2 4/2 4/2 4/2 4/2 4/2 4/2NOISE LEVELSSound power (3) dB(A) 84 85 82 83 83 84 84 85 86Sound pressure (4) dB(A) 52 53 50 51 51 52 52 53 54SIZEA (5) mm 4602 4602 4110 4110 4110 5110 5110 5110 5110B (5) mm 1277 1277 2220 2220 2220 2220 2220 2220 2220H (5) mm 2350 2350 2150 2150 2150 2150 2150 2430 2430Operating weight (5) kg 1920 2000 2280 2410 2580 2880 3040 3380 3520NECS-FC-NGFREE-COOLING OFFCooling capacity (1) kW 160 184 171 198 221 249 281 322 361Total power input (1) kW 53,3 59,2 57,1 66,2 75,2 83,5 90,3 104 120EER 3 3,11 2,99 2,99 2,94 2,99 3,12 3,09 3,01FREE-COOLING ON 100%Cooling capacity (2) kW 160 184 178 198 221 249 281 322 361Total power input (2) kW 3,50 4,40 3,50 5,20 4,80 5,10 5,20 5,10 6,90Total Free-Cooling temperature (2) °C -4,70 -5,80 -4,60 -4,70 -6,30 -4,60 -5,80 -6 -5,90COMPRESSORSNo. Compressors/No. Circuits N. 2/1 2/1 4/2 4/2 4/2 4/2 4/2 4/2 4/2NOISE LEVELSSound power (3) dB(A) 84 85 82 83 83 84 84 85 86Sound pressure (4) dB(A) 53 54 50 51 51 52 52 53 54SIZEA (5) mm 4602 4602 4110 4110 4110 5110 5110 5110 5110B (5) mm 1277 1277 2200 2200 2200 2200 2200 2200 2200H (5) mm 2350 2350 2150 2150 2150 2150 2150 2430 2430Operating weight (5) kg 2060 2150 2590 2730 2910 3250 3420 3820 3970

A

B

H

AB

H

Page 121: Products Guide V01 - ParagonEfficient project management thanks to Climaveneta as unique project leader. Complete and specialized Organization Climaveneta qualifies itself for the

119

Page 122: Products Guide V01 - ParagonEfficient project management thanks to Climaveneta as unique project leader. Complete and specialized Organization Climaveneta qualifies itself for the

120

Main accessoriesEC fans with electronic DC brushless motor

Compressor power factor device

Electronic expansion valve

Remote keyboard (distance to 200m and to 500m)

Set-up for remote connectivity with ModBus/Echelon/Bacnet protocol cards

Hydronic group

FeaturesRANGE

Extended capacity range

ENERGY SAVING

Energy saving guaranteed by free-cooling, which exploits the low external air temperatures; free-cooling control with optional modulating valve

INTEGRATED HYDRONIC MODULE

It consists of 1 or 2 pumps, 2 or 4-pole motor, with high or low head options to satisfy different applications

Configurations- base function

NG function for free-cooling without use of glycole

VersionsB base version

SL super-low noise version

CommandsW3000SE LargeThe W3000 SE Large controller offers advanced functions and algorithms. The keypad is generously sized with full operating status display. The commands and detailed LCD display make access to the units settings easy and safe. These resources allow to consult and intervene on the unit by means of a multi-level menu, with selectable language setting. The diagnostics includes a complete alarm management, with the “black-box” and alarm logging functions for enhanced analysis of the unit operation. For multiple units systems, the regulation of the resources, via optional proprietary devices, can be implemented. Energy metering, for both consumption and capacity, can also be developed. Supervision can be easily developed via proprietary devices or the integration in third party systems by means of the most common protocols as ModBus, Bacnet, Bacnet-over-IP, Echelon LonWorks. Compatibility with the remote keyboard managing up to 10 units. Availability of an internal real time clock for operation scheduling (4-day profiles with 10 hour belts). The regulation features the continuous modulation of capacity, based on a dynamic dead band and referring to the leaving water temperature. As alternative, step-wise regulation is also available, referred to the return water temperature with selectable proportional- or proportional-integral logic.

Hydronic - chiller

FOCS-FC 1502÷4822

Chiller, air source with free-cooling

329 - 1229 kW Unit DescriptionOutdoor unit for the production of chilled water with semi-hermetic screw compressors optimized for R134a, axial-flow fans, condensing coil with copper tubes and aluminium fins, shell and tube evaporator design by Climaveneta and thermostatic expansion valve. Base and supporting structure and panels are of galvanized epoxy powder coated steel with increased thickness. This air-cooled range, fitted with FREE-COOLING coils, is for use in civil and industrial installations whenever the need for cooling continues throughout the cold months, or when the external air temperature is lower than the temperature of the liquid returning from the installation. During freecooling operation the fluid is cooled by means of the external air, thus reducing the load on the compressors or even completely substituting them. The necessary cooling capacity is therefore obtained with almost zero energy expenditure (FREECOOLING 100 % = EER 25). Further more the NG configuration complies with applications where the use of ethylene glycol is not desired or permitted.

Page 123: Products Guide V01 - ParagonEfficient project management thanks to Climaveneta as unique project leader. Complete and specialized Organization Climaveneta qualifies itself for the

121

Note:

1 Evaporator water (in/out): 15/10°C; Condenser air (in): 30°C; Ethylene glycol: 30% (not applicable to NG configurations).

2 Evaporator water (in/out): 15/10°C; Ethylene glycol: 30 % (not applicable to NG configurations).

3 Sound power on the basis of measurements made in compliance with ISO 9614 and Eurovent 8/1 for Eurovent certified units; in compliance with ISO 3744 for non-certified units.

4 Average sound pressure level, at 10m distance, unit in a free field on a reflective surface; non-binding value obtained from the sound power level.

5 Unit in standard configuration/execution, without optional accessories

FOCS-FC / BModels 1502 1702 1902 1922 2022 2602 2702 2722 3602 4202 4212 4222 4822FOCS-FCFREE-COOLING OFFCooling capacity (1) kW 329 369 417 454 502 579 636 711 858 994 1076 1126 1229Total power input (1) kW 96,4 114 136 147 168 191 221 221 298 333 336 355 395EER 3,41 3,24 3,07 3,09 2,99 3,03 2,88 3,22 2,88 2,98 3,20 3,17 3,11FREE-COOLING ON 100%Cooling capacity (2) kW 329 369 417 454 502 579 636 711 858 994 1076 1126 1229Total power input (2) kW 9,60 9,60 21 21 21 25,2 25,2 29,4 33,6 42 50,4 50,4 50,4Total Free-Cooling temperature (2) °C 1,70 0,70 1,80 1,10 0,10 0,60 -0,50 0,60 0 0,10 1,30 0,90 0COMPRESSORSNo. Compressors/No. Circuits N. 2 / 2 2 / 2 2 / 2 2 / 2 2 / 2 2 / 2 2 / 2 2 / 2 2 / 2 2 / 2 2 / 2 2 / 2 2 / 2NOISE LEVELSSound power (3) dB(A) 99 99 99 99 99 101 101 102 102 103 105 105 105Sound pressure (4) dB(A) 67 67 67 67 67 69 69 69 69 70 72 72 72SIZEA (5) mm 4000 4000 4900 4900 4900 5800 5800 7000 7900 10000 11800 11800 11800B (5) mm 2500 2500 2500 2500 2500 2500 2500 2500 2500 2500 2500 2500 2500H (5) mm 2260 2260 2260 2260 2260 2260 2260 2260 2260 2260 2260 2260 2260Operating weight (5) kg 4810 4810 5310 5630 6590 7170 7190 7940 9670 11500 12530 12600 12660FOCS-FC/NGFREE-COOLING OFFCooling capacity (1) kW 338 379 428 466 516 595 653 730 881 1021 1105 1157 1262Total power input (1) kW 104 122 136 148 169 192 222 222 299 335 338 356 397EER 3,25 3,11 3,15 3,15 3,05 3,10 2,94 3,29 2,95 3,05 3,27 3,25 3,18FREE-COOLING ON 100%Cooling capacity (2) kW 338 379 428 466 516 595 653 730 881 1021 1105 1157 1262Total power input (2) kW 16,8 16,8 21 21 21 25,2 25,2 29,4 33,6 42 50,4 50,4 50,4Total Free-Cooling temperature (2) °C -1,30 -2,30 -1,20 -1,90 -2,90 -2,40 -3,40 -2,40 -3 -2,80 -1,70 -2,10 -3COMPRESSORSNo. Compressors/No. Circuits N. 2 / 2 2 / 2 2 / 2 2 / 2 2 / 2 2 / 2 2 / 2 2 / 2 2 / 2 2 / 2 2 / 2 2 / 2 2 / 2NOISE LEVELSSound power (3) dB(A) 99 99 99 99 99 101 101 102 102 103 105 105 105Sound pressure (4) dB(A) 67 67 67 67 67 69 69 69 69 70 72 72 72SIZEA (5) mm 4000 4000 4900 4900 4900 5800 5800 7000 7900 10000 11800 11800 11800B (5) mm 2260 2260 2260 2260 2260 2260 2260 2260 2260 2260 2260 2260 2260H (5) mm 2500 2500 2500 2500 2500 2500 2500 2500 2500 2500 2500 2500 2500Operating weight (5) kg 5130 5130 5710 6030 6970 7630 7700 8440 10410 12130 13330 13580 13640

COOLINGFREE COOLING

r HFCR-134a

SCREWAXIALSHELL & TUBES

Page 124: Products Guide V01 - ParagonEfficient project management thanks to Climaveneta as unique project leader. Complete and specialized Organization Climaveneta qualifies itself for the

122

Minimum clearance required1502-4822

Switchboard side mm 1800Switchboard opposite side mm 1500Condensation coil side mm 2000

Note:

1 Evaporator water (in/out): 15/10°C; Condenser air (in): 30°C; Ethylene glycol: 30% (not applicable to NG configurations).

2 Evaporator water (in/out): 15/10°C; Ethylene glycol: 30 % (not applicable to NG configurations).

3 Sound power on the basis of measurements made in compliance with ISO 9614 and Eurovent 8/1 for Eurovent certified units; in compliance with ISO 3744 for non-certified units.

4 Average sound pressure level, at 10m distance, unit in a free field on a reflective surface; non-binding value obtained from the sound power level.

5 Unit in standard configuration/execution, without optional accessories

FOCS-FC / SLModels 1502 1702 1902 1922 2022 2602 2702 2722 3602 4202 4212 4222 4822FOCS-FCFREE-COOLING OFFCooling capacity (1) kW 315 348 398 435 503 548 597 683 808 936 1030 1080 1171Total power input (1) kW 102 122 135 150 161 194 229 229 309 339 338 362 413EER 3,09 3,25 3,35 3,30 3,12 3,22 3,01 3,38 3,01 3,16 3,05 3,38 3,24FREE-COOLING ON 100%Cooling capacity (2) kW 315 348 398 435 503 548 597 683 808 936 1030 1080 1171Total power input (2) kW 9,60 9,60 12 12 14,4 14,4 14,4 16,8 19,2 24 28,8 28,8 28,8Total Free-Cooling temperature (2) °C 0,40 -0,50 0,50 -0,30 0,20 -0,70 -1,60 -0,80 -1,20 -1,10 -0,10 -0,50 -1,40COMPRESSORSNo. Compressors/No. Circuits N. 2 / 2 2 / 2 2 / 2 2 / 2 2 / 2 2 / 2 2 / 2 2 / 2 2 / 2 2 / 2 2 / 2 2 / 2 2 / 2NOISE LEVELSSound power (3) dB(A) 92 92 92 92 94 94 94 95 95 95 97 97 97Sound pressure (4) dB(A) 60 60 60 60 62 62 62 62 62 62 64 64 64SIZEA (5) mm 4000 4000 4900 4900 5800 5800 5800 7000 7900 10000 11800 11800 11800B (5) mm 2500 2500 2500 2500 2500 2500 2500 2500 2500 2500 2500 2500 2500H (5) mm 2260 2260 2260 2260 2260 2260 2260 2260 2260 2260 2260 2260 2260Operating weight (5) kg 4900 4900 5390 5710 7240 7260 7280 8050 9790 11660 12710 12780 12840FOCS-FC/NGFREE-COOLING OFFCooling capacity (1) kW 323 357 409 447 516 562 613 702 830 961 1058 1109 1203Total power input (1) kW 93 103 123 151 162 195 231 230 310 341 340 364 415EER 3,15 2,91 3,02 2,96 3,18 2,89 2,70 3,05 2,68 2,82 3,11 3,05 2,90FREE-COOLING ON 100%Cooling capacity (2) kW 323 357 409 447 516 562 613 702 830 961 1058 1109 1203Total power input (2) kW 9,60 9,60 12 12 14,4 14,4 14,4 16,8 19,2 24 28,8 28,8 28,8Total Free-Cooling temperature (2) °C -2,65 -3,51 -2,47 -3,29 -2,77 -3,68 -4,61 -3,80 -4,18 -4,12 -3,12 -3,53 -4,38COMPRESSORSNo. Compressors/No. Circuits N. 2 / 2 2 / 2 2 / 2 2 / 2 2 / 2 2 / 2 2 / 2 2 / 2 2 / 2 2 / 2 2 / 2 2 / 2 2 / 2NOISE LEVELSSound power (3) dB(A) 92 92 92 92 94 94 94 95 95 95 97 97 97Sound pressure (4) dB(A) 60 60 60 60 62 62 62 62 62 62 64 64 64SIZEA (5) mm 4000 4000 4900 4900 5800 5800 5800 7000 7900 10000 11800 11800 11800B (5) mm 2260 2260 2260 2260 2260 2260 2260 2260 2260 2260 2260 2260 2260H (5) mm 2500 2500 2500 2500 2500 2500 2500 2500 2500 2500 2500 2500 2500Operating weight (5) kg 5210 5210 5790 6110 7600 7720 7790 8550 10530 12290 13510 13760 13820

A

B

H

Page 125: Products Guide V01 - ParagonEfficient project management thanks to Climaveneta as unique project leader. Complete and specialized Organization Climaveneta qualifies itself for the

123

Page 126: Products Guide V01 - ParagonEfficient project management thanks to Climaveneta as unique project leader. Complete and specialized Organization Climaveneta qualifies itself for the

124

Main accessoriesSet-up for remote connectivity with ModBus/Echelon/Bacnet protocol cards

Remote keyboard (distance to 200m and to 500m)

Soft starters

Rubber anti-vibration mounting kit

Horizontal or vertical air outflow

FeaturesREFRIGERANT GAS R410A

The use of R410A has resulted in units offering better energy efficiency in full respect for the environment (ODP = 0)

TOTAL VERSATILITY

The NECS-C units are available with both vertical and horizontal air outflow. The horizontal outflow version is particularly effective in installations where the height of the technical compartment does not allow the traditional vertical outflow

HIGH PERFORMANCE CENTRIFUGAL FANS

The units are fitted with statically and dynamically balanced double-inlet centrifugal fans coupled by belt and pulleys. Useful static pressure up to 180 Pa.

INTEGRATED HYDRONIC MODULE

The incorporated hydronic unit already contains the main water circuit components; it is available in various configurations with one or two pumps with high or low head

Configurations- base function

D partial condensing heat recovery function

R total condensing heat recovery function

VersionsB base version

HT high efficiency, high outdoor temperature version

CommandsW3000 Base / W3000SE CompactThe controller can be chosen as: - W3000 Base: keypad and LED display - W3000SE Compact: the keypad features an easy-to-use interface and a complete LCD display, allowing to consult and intervene on the unit by means of a multi-level menu, with selectable language setting. The diagnostics includes a complete alarm management, with the “black-box” and alarm logging functions for enhanced analysis of the unit operation. Compatibility with the remote keyboard managing up to 10 units. Availability of an internal real time clock for operation scheduling (4-day profiles with 10 hour belts). Common features: The regulation is based on the exclusive QuickMind algorithm, including self-adaptive control logics, beneficial in low water content systems. As alternatives the proportional- or proportional-integral regulations are also available. For multiple units systems, the regulation of the resources, via optional proprietary devices, can be implemented. Energy metering, for both consumption and capacity, can also be developed. Supervision can be easily developed via proprietary devices or the integration in third party systems by means of the most common protocols as ModBus, Bacnet, Bacnet-over-IP, Echelon LonWorks.

Hydronic - chiller

NECS-C 0152÷1204

Chiller, air source for indoor installation

37,1 - 325 kWUnit DescriptionIndoor unit for the production of chilled water with hermetic rotary scroll compressors dedicated to the use of R410A, centrifugal fans, braze-welded plate-type exchanger and thermal expansion valve. External panels in pre-clad sheet steel (simil Peraluman) and base in galvanised steel with paint finish. The range includes the single-circuit two-compressor versions and the dual circuit four-compressor versions.

Page 127: Products Guide V01 - ParagonEfficient project management thanks to Climaveneta as unique project leader. Complete and specialized Organization Climaveneta qualifies itself for the

125

Note:

1 Evaporator water (in/out) = 12/7°C; Condenser air (in) = 35°C.

2 Useful pressure to be specified at the time of placing the order.

3 Total sound power of the fans as declared by the manufacturer referred to nominal speed of rotation and useful static head of 120 Pa on delivery side.

4 Unit in standard configuration/execution, without optional accessories

Models 0552 0612 0604 0704 0804 0904 1004 1104 1204COOLINGCooling capacity (1) kW 138 159 152 172 195 222 244 281 312Total power input (1) kW 58,3 67,2 62,5 73,1 83,5 89,6 102 115 133EER 2,53 2,59 2,66 2,55 2,57 2,69 2,60 2,62 2,52ESEER 4,17 3,94 3,86 3,72 3,61 3,97 3,77 3,88 3,74COMPRESSORSNo. Compressors/No. Circuits N. 2/1 2/1 4/2 4/2 4/2 4/2 4/2 4/2 4/2FANSFan air flow m3/h 33984 51012 47988 51012 68004 64008 68004 68004 84996Max AESP (2) Pa 120 120 120 120 120 120 120 120 120NOISE LEVELSSound power (3) dB(A) 93 95 94 95 96 95 96 96 97SIZEA (4) mm 3602 3602 3602 3602 4602 4602 4602 4602 5602B (4) mm 1104 1104 1277 1277 1277 1277 1277 1277 1277H (4) mm 1927 1927 1900 1900 2235 2235 2235 2235 2235Operating weight (4) kg 1450 1550 1845 1940 2310 2445 2515 2695 2885

NECS-C / BModels 0152 0182 0202 0252 0302 0352 0412 0452 0512COOLINGCooling capacity (1) kW 37,1 43 50,5 57 74,8 86,4 97,9 109 121Total power input (1) kW 15,7 18,3 20,6 23,2 30,4 36,8 40,7 46,8 51,5EER 2,67 2,64 2,72 2,69 2,65 2,60 2,64 2,53 2,54ESEER 4,61 4,30 4,46 4,35 4,18 3,86 3,88 3,73 3,74COMPRESSORSNo. Compressors/No. Circuits N. 2/1 2/1 2/1 2/1 2/1 2/1 2/1 2/1 2/1FANSFan air flow m3/h 15984 18000 18000 18000 20016 32004 32004 33984 33984Max AESP (2) Pa 120 120 120 120 120 120 120 120 120NOISE LEVELSSound power (3) dB(A) 82 85 85 85 87 92 92 93 93SIZEA (4) mm 2200 2200 2200 2200 2200 2602 2602 2602 2602B (4) mm 920 920 920 920 920 1104 1104 1104 1104H (4) mm 1642 1642 1642 1642 1642 1927 1927 1927 1927Operating weight (4) kg 670 670 700 720 880 1120 1170 1210 1260

COOLING

r HFCR-410A

SCROLLCENTRIFUGALPLATES

Page 128: Products Guide V01 - ParagonEfficient project management thanks to Climaveneta as unique project leader. Complete and specialized Organization Climaveneta qualifies itself for the

126

Minimum clearance required0152-1204

Switchboard side mm 1000Switchboard opposite side mm 1000Opposite side of cond. coil mm 1000Condensation coil side mm 2000

Note:

1 Evaporator water (in/out) = 12/7°C; Condenser air (in) = 35°C.

2 Useful pressure to be specified at the time of placing the order.

3 Total sound power of the fans as declared by the manufacturer referred to nominal speed of rotation and useful static head of 120 Pa on delivery side.

4 Unit in standard configuration/execution, without optional accessories

Models 0552 0612 0604 0704 0804 0904 1004 1104 1204COOLINGCooling capacity (1) kW 148 165 158 183 203 228 257 296 325Total power input (1) kW 57,8 64,6 61,2 69 79,9 89,1 99,3 112 128EER 2,98 2,80 2,85 2,96 2,81 2,80 2,86 2,88 2,74ESEER 3,97 3,94 3,54 3,94 3,67 3,77 3,71 3,84 3,75COMPRESSORSNo. Compressors/No. Circuits N. 2/1 2/1 4/2 4/2 4/2 4/2 4/2 4/2 4/2FANSFan air flow m3/h 51012 51012 51012 64008 68004 68004 84996 84996 84996Max AESP (2) PaNOISE LEVELSSound power (3) dB(A) 95 95 95 95 96 96 97 97 97SIZEA (4) mm 3602 3602 3602 4602 4602 4602 5602 5602 5602B (4) mm 1104 1104 1277 1277 1277 1277 1277 1277 1277H (4) mm 1927 1927 1900 2235 2235 2235 2235 2235 2235Operating weight (4) kg 1560 1630 1920 2320 2380 2580 2845 3055 3115

NECS-C / HTModels 0152 0182 0202 0252 0302 0352 0412 0452 0512COOLINGCooling capacity (1) kW 39 45,5 52,7 59,4 80 91,5 103 114 130Total power input (1) kW 14,9 17,4 20 22,4 30,6 34,6 39,8 44,1 50,8EER 2,98 2,97 2,94 2,93 2,96 2,95 2,86 2,83 2,88ESEER 4,83 4,48 4,51 4,42 3,93 4,01 3,81 4,03 3,78COMPRESSORSNo. Compressors/No. Circuits N. 2/1 2/1 2/1 2/1 2/1 2/1 2/1 2/1 2/1FANSFan air flow m3/h 15984 19008 19008 19008 32004 32004 33984 33984 51012Max AESP (2) PaNOISE LEVELSSound power (3) dB(A) 82 86 86 86 92 92 93 93 95SIZEA (4) mm 2200 2200 2200 2200 2602 2602 2602 3602 3602B (4) mm 920 920 920 920 1104 1104 1104 1104 1104H (4) mm 1642 1642 1642 1642 1927 1927 1927 1927 1927Operating weight (4) kg 690 710 730 760 1090 1170 1230 1400 1490

AB

H

Page 129: Products Guide V01 - ParagonEfficient project management thanks to Climaveneta as unique project leader. Complete and specialized Organization Climaveneta qualifies itself for the

127

Page 130: Products Guide V01 - ParagonEfficient project management thanks to Climaveneta as unique project leader. Complete and specialized Organization Climaveneta qualifies itself for the

128

Main accessoriesSet-up for remote connectivity with ModBus/Echelon/Bacnet protocol cardsCondensing control device: two or three-way modulating pressure-controlled valve and inverter on pumpsWater connections directed upwards (for 2 compressors units only)

Acoustical enclosure to reduce the noise emissions.

Rubber anti-vibration mounting kit. Spring anti-vibration mounting kit (4 compressors models only)

FeaturesREFRIGERANT GAS R410A

The use of R410A has resulted in units offering better energy efficiency in full respect for the environment (ODP = 0)

TOTAL VERSATILITY

Climaveneta has designed the NECS-W units with a range of integral accessories in mind for operation with total water loss (well, water bed, etc.), dry cooler or cooling tower so as to satisfy all service system and installation requirements.INTEGRATED HYDRONIC MODULE ON COOLER/CONDENSER SIDEThe built-in hydronic module includes the main water circuit components; it is available in various configurations with one or two pumps with high or low head both on the evaporator and the condenser side.

INTEGRATED CONDENSATION´S CONTROL

The electronics of the units manages the most suitable condensing control for each type of application: pressure-controlled valve, two or three-way modulating valve and inverter control for the pumps

Configurations- base function

H function with heat pump, reversible on hydraulic side

VersionsB base version

CommandsW3000 Base / W3000SE CompactThe controller can be chosen as: - W3000 Base: keypad and LED display - W3000SE Compact: the keypad features an easy-to-use interface and a complete LCD display, allowing to consult and intervene on the unit by means of a multi-level menu, with selectable language setting. The diagnostics includes a complete alarm management, with the “black-box” and alarm logging functions for enhanced analysis of the unit operation. Compatibility with the remote keyboard managing up to 10 units. Availability of an internal real time clock for operation scheduling (4-day profiles with 10 hour belts). Common features: The regulation is based on the exclusive QuickMind algorithm, including self-adaptive control logics, beneficial in low water content systems. As alternatives the proportional- or proportional-integral regulations are also available. For multiple units systems, the regulation of the resources, via optional proprietary devices, can be implemented. Energy metering, for both consumption and capacity, can also be developed. Supervision can be easily developed via proprietary devices or the integration in third party systems by means of the most common protocols as ModBus, Bacnet, Bacnet-over-IP, Echelon LonWorks.

Hydronic - chiller

NECS-W 0152÷1204

Chiller, water source

43,4 - 371 kWUnit DescriptionWater-cooled indoor unit for the production of chilled water with hermetic rotary Scroll compressors, braze-welded plate-type exchanger and thermal expansion valve. External panels in pre-clad sheet steel (simil-Peraluman) and structure in galvanised steel with paint finish. The range includes the single-circuit two-compressor versions and the dual circuit four-compressor versions.

Page 131: Products Guide V01 - ParagonEfficient project management thanks to Climaveneta as unique project leader. Complete and specialized Organization Climaveneta qualifies itself for the

129

Minimum clearance required0152-0612 0604-1204

Switchboard side mm 800 1000Switchboard opposite side mm 600 1000Unit’s side mm 600 1000

Note:

1 Evaporator water (in/out) = 12/7°C, condenser water (in/out) = 30/35°C, based on Eurovent Standard

2 Evaporator water (in/out) = 12/7°C; Condenser water (in/out) = 40/45°C.

3 Sound power on the basis of measurements made in compliance with ISO 9614 and Eurovent 8/1 for Eurovent certified units; in compliance with ISO 3744 for non-certified units.

4 Sound pressure in open field conditions on reflecting surface (directivity factor Q=2), average value on longest side, at 1 m from the outer surface and at 1 m height in relation to the unit supporting base.

5 Unit in standard configuration/execution, without optional accessories

Models 0552 0612 0604 0704 0804 0904 1004 1104 1204COOLING ONLYCooling capacity (1) kW 165 186 174 203 228 258 288 329 371 Total power input (1) kW 36,9 41,6 38,9 45,2 51,6 58,0 64,0 74,0 83,5 Condernser heating capacity (1) 200 225 211 245 276 312 348 398 450 EER 4,47 4,48 4,47 4,48 4,42 4,45 4,50 4,44 4,44 ESEER 5,90 5,80 5,80 5,90 5,80 5,90 5,90 6,00 5,90 HEATING ONLY (only -H)Heating capacity (2) kW 190 215 202 234 263 297 332 379 428 Total power input (2) kW 45,9 51,8 49,2 56,6 64,1 72,1 79,5 91,9 104 COP 4,14 4,14 4,11 4,13 4,10 4,12 4,17 4,13 4,12 COMPRESSORSNo. Compressors/No. Circuits N. 2/1 2/1 4/2 4/2 4/2 4/2 4/2 4/2 4/2 NOISE LEVELSSound power (3) dB(A) 79 79 86 87 88 89 90 91 91 Sound pressure (4) dB(A)SIZEA (5) mm 1222 1222 2227 2227 2227 2227 2227 2227 2227 B (5) mm 873 873 887 887 887 887 887 887 887H (5) mm 1496 1496 1780 1780 1780 1780 1780 1780 1780 Operating weight (5) kg 790 830 1090 1165 1245 1290 1395 1500 1585

NECS-W / BModels 0152 0182 0202 0252 0262 0302 0352 0412 0452 0512COOLING ONLYCooling capacity (1) kW 43,4 50,1 58,9 66,4 72,6 86,7 101 115 129 144 Total power input (1) kW 10,0 11,3 13,0 15,2 16,6 19,5 22,7 25,9 28,9 32,2 Condernser heating capacity (1) 52,8 60,7 71,2 80,7 88,2 105 123 139 156 174 EER 4,34 4,43 4,53 4,37 4,37 4,45 4,46 4,43 4,45 4,46 ESEER 5,80 6,00 6,00 5,70 5,60 5,70 5,80 5,70 5,80 5,80 HEATING ONLY (only -H)Heating capacity (2) kW 50,5 58,2 68,0 77,0 85,0 101 117 132 148 165 Total power input (2) kW 12,9 14,3 16,7 19,2 21,1 24,7 28,7 32,2 36,0 40,0 COP 3,91 4,07 4,07 4,01 4,03 4,09 4,07 4,10 4,12 4,14 COMPRESSORSNo. Compressors/No. Circuits N. 2/1 2/1 2/1 2/1 2/1 2/1 2/1 2/1 2/1 2/1 NOISE LEVELSSound power (3) dB(A) 73 74 74 74 75 76 77 77 78 78 Sound pressure (4) dB(A) SIZEA (5) mm 1055 1055 1055 1055 1055 1222 1222 1222 1222 1222 B (5) mm 469 469 469 469 469 873 873 873 873 873H (5) mm 1255 1255 1255 1255 1255 1496 1496 1496 1496 1496 Operating weight (5) kg 290 305 315 325 330 585 605 660 685 740

COOLINGHEATING

r HFCR-410A

SCROLLPLATES

H

BA

H

B A

Page 132: Products Guide V01 - ParagonEfficient project management thanks to Climaveneta as unique project leader. Complete and specialized Organization Climaveneta qualifies itself for the

130

Main accessoriesCompressor power factor device

Electronic expansion valve

Pressostatic control valve

Remote keyboard (distance to 200m and to 500m)

Set-up for remote connectivity with ModBus, Echelon LonTalk, Bacnet protocol board

FeaturesFLEXIBILITY

Flexibility in applications thanks to the many available functions and versions

ADAPTABILITY

Adaptability at the buildings cooling request thanks to the continuous capacity regulation, assured by sophisticated controls logic

HEAT PUMP OPTION

Heat pump function water circuit side reversal

Configurations- base function

D partial condensing heat recovery function

H function with heat pump, reversible on hydraulic side

R total condensing heat recovery function

VersionsB base version

CommandsW3000SE LargeThe W3000 SE Large controller offers advanced functions and algorithms. The keypad is generously sized with full operating status display. The commands and detailed LCD display make access to the units settings easy and safe. These resources allow to consult and intervene on the unit by means of a multi-level menu, with selectable language setting. The diagnostics includes a complete alarm management, with the “black-box” and alarm logging functions for enhanced analysis of the unit operation. For multiple units systems, the regulation of the resources, via optional proprietary devices, can be implemented. Energy metering, for both consumption and capacity, can also be developed. Supervision can be easily developed via proprietary devices or the integration in third party systems by means of the most common protocols as ModBus, Bacnet, Bacnet-over-IP, Echelon LonWorks. Compatibility with the remote keyboard managing up to 10 units. Availability of an internal real time clock for operation scheduling (4-day profiles with 10 hour belts). The regulation features the continuous modulation of capacity, based on a dynamic dead band and referring to the leaving water temperature. As alternative, step-wise regulation is also available, referred to the return water temperature with selectable proportional- or proportional-integral logic.

Hydronic - chiller

FOCS-W 0401÷1902

Chiller, water source

87,0 - 447 kWUnit DescriptionIndoor unit for the production of chilled water with semi-hermetic screw compressors optimized for R134a, thermostatic expansion valve, shell and tube condenser and evaporator. Base and supporting structure and panels are of galvanized epoxy powder coated steel with increased thickness. Flexible and reliable unit; it easily adapts itself to different thermal load conditions thanks to the precise thermoregulation. The high performances level is achieved thanks to the accurate sizing of all internal components.

Page 133: Products Guide V01 - ParagonEfficient project management thanks to Climaveneta as unique project leader. Complete and specialized Organization Climaveneta qualifies itself for the

131

Minimum clearance required0401-1902

Switchboard side mm 650Cooler water connections side (minimum)

mm 450

Condenser water connections side mm 900Condenser water fittings opposite side (minimum)

mm 600

Note:

1 Evaporator water (in/out) = 12/7°C, condenser water (in/out) = 30/35°C, based on Eurovent Standard

2 Evaporator water (in/out): 12/7°C; Condenser water (in/out): 30/35°C; Desuperheater water (in/out): 40/45°C.

3 Evaporator water (in/out) = 12/7°C; Recovery unit water (in/out) = 40/45°C

4 Evaporator water (in/out) = 12/7°C; Condenser water (in/out) = 40/45°C.

5 Sound power on the basis of measurements made in compliance with ISO 9614 and Eurovent 8/1 for Eurovent certified units; in compliance with ISO 3744 for non-certified units.

6 Sound pressure in open field conditions on reflecting surface (directivity factor Q=2), average value on longest side, at 1 m from the outer surface and at 1 m height in relation to the unit supporting base.

7 Unit in standard configuration/execution, without optional accessories

Models 0802 1002 1102 1302 1502 1702 1902COOLING ONLYCooling capacity (1) kW 178 217 251 298 340 393 447Total power input (1) kW 39,4 49,2 55,9 65,6 74,4 85,4 99,6Condernser heating capacity (1) 217 266 307 364 414 478 547EER 4,52 4,41 4,49 4,54 4,57 4,60 4,49ESEER 5,39 5,52 5,24 5,49 5,67 5,70 5,61COOLING WITH PARTIAL RECOVERY (only -D)Cooling capacity (2) kW 184 217 251 298 340 393 447Total power input (2) kW 38 49,2 55,8 65,6 74,5 85,4 99,5Desuperheater heating capacity (2) kW 17 21,3 24,1 28,3 32,2 36,9 43COOLING WITH TOTAL RECOVERY (only -R)Cooling capacity (3) kW 158 194 223 265 304 348 397Total power input (3) kW 47,1 58,7 67,9 78,6 88,6 102 118Heat recovery capacity (3) kW 189 249 287 339 387 445 509HEATING ONLY (only -H)Heating capacity (4) kW 194 239 276 326 372 428 489Total power input (4) kW 46,6 58 67,2 77,8 87,5 101 116COP 4,16 4,12 4,11 4,19 4,25 4,23 4,18COMPRESSORSNo. Compressors/No. Circuits N. 2/2 2/2 2/2 2/2 2/2 2/2 2/2NOISE LEVELSSound power (5) dB(A) 94 95 97 97 97 97 97Sound pressure (6) dB(A) * * * * * * *SIZEA (7) mm 3200 3200 3200 3500 3500 3500 3500B (7) mm 1500 1500 1500 1200 1200 1200 1200H (7) mm 1200 1200 1200 1800 1800 1800 1800Operating weight (7) kg 1470 1490 1930 2220 2260 2320 2720

FOCS-W / BModels 0401 0501 0551 0651 0751 0851 0951COOLING ONLYCooling capacity (1) kW 87 107 130 147 165 198 221Total power input (1) kW 19,6 24,6 28,1 32,6 37 42,8 49,6Condernser heating capacity (1) 107 132 158 180 202 241 271EER 4,44 4,35 4,63 4,51 4,46 4,63 4,46ESEER 5,15 5,32 5,25 5,29 5,40 5,54 5,42COOLING WITH PARTIAL RECOVERY (only -D)Cooling capacity (2) kW 90,2 111 135 153 171 205 221Total power input (2) kW 18,9 23,6 27,1 31,6 35,6 41,2 49,6Desuperheater heating capacity (2) kW 8,50 10,6 12,1 14,1 15,9 18,5 21,4COOLING WITH TOTAL RECOVERY (only -R)Cooling capacity (3) kW 77,4 95,2 116 131 147 175 197Total power input (3) kW 23,5 29,2 34,2 39,2 44 51,2 59,1Heat recovery capacity (3) kW 99,5 123 148 168 188 202 252HEATING ONLY (only -H)Heating capacity (4) kW 95,7 118 142 162 181 215 243Total power input (4) kW 23,2 28,9 33,8 38,9 43,4 50,7 58,4COP 4,13 4,09 4,20 4,16 4,17 4,24 4,16COMPRESSORSNo. Compressors/No. Circuits N. 1/1 1/1 1/1 1/1 1/1 1/1 1/1NOISE LEVELSSound power (5) dB(A) 91 92 94 94 94 94 94Sound pressure (6) dB(A) * * * * * * *SIZEA (7) mm 2300 2500 2500 2500 2500 3200 3200B (7) mm 1000 1000 1000 1000 1000 1500 1500H (7) mm 1500 1500 1500 1500 1500 1200 1200Operating weight (7) kg 800 840 1160 1180 1190 1270 1350

COOLINGHEATING

r HFCR-134a

SCREWSHELL & TUBES

H

BA

Page 134: Products Guide V01 - ParagonEfficient project management thanks to Climaveneta as unique project leader. Complete and specialized Organization Climaveneta qualifies itself for the

132

Main accessoriesKit HWT, High Water Temperature, to produce hot water up to 60°C

Integral acoustical enclosure (type base or plus)

VPF (Variable Primary Flow) system

Set-up for remote connectivity with ModBus/Echelon/Bacnet protocol cards

FeaturesHIGH EFFICIENCY

The version ´CA-E´ is characterized by efficiency beyond the ´Class A´ for Eurovent. The technological choices adopted assure the minimization of operating costs and therefore a quick payback time.

ADAPTABILITY

Adaptability at the buildings cooling request thanks to the continuous capacity regulation, assured by sophisticated controls logic

HEAT PUMP FUNCTION

Heat pump function water circuit side reversal

SILENT OPERATION

Silent operation thanks to the accurate units design. Optional integral acoustic enclosure, further reduces the sound level beyond the best on market

Configurations- base function

D partial condensing heat recovery function

H function with heat pump, reversible on hydraulic side

R total condensing heat recovery function

Versions

CA Class A of efficiency

CA-E Very high efficiency version: Class A enhanced

CommandsW3000SE LargeThe W3000 SE Large controller offers advanced functions and algorithms. The keypad is generously sized with fulloperating status display. The commands and detailed LCD display make access to the units settings easy and safe.These resources allow to consult and intervene on the unit by means of a multi-level menu, with selectable languagesetting. The diagnostics includes a complete alarm management, with the “black-box” and alarm logging functionsfor enhanced analysis of the unit operation. For multiple units systems, the regulation of the resources, via optionalproprietary devices, can be implemented. Energy metering, for both consumption and capacity, can also be developed.Supervision can be easily developed via proprietary devices or the integration in third party systems by means of themost common protocols as ModBus, Bacnet, Bacnet-over-IP, Echelon LonWorks. Compatibility with the remote keyboardmanaging up to 10 units. Availability of an internal real time clock for operation scheduling (4-day profiles with 10 hourbelts). The regulation features the continuous modulation of capacity, based on a dynamic dead band and referring to theleaving water temperature. As alternative, step-wise regulation is also available, referred to the return water temperaturewith selectable proportional- or proportional-integral logic. As option (VPF package), the modulation of capacity isintegrated with the modulation of the water flow, by means of inverter and dedicated resources for the hydraulic circuit.

Hydronic - chiller

FOCS2-W 1301÷9604

High efficiency chiller, water source

306 - 2416 kW Unit DescriptionUnit for indoor installation for chilled water production. Semihermetic screw compressorsoptimized to operate with low compression ratio and R134a; shell and tubes condenserand direct expansion evaporator; electronic expansion valve. Frame in polyester-paintedgalvanized steel. High efficiency unit: the innovative optimized compressors and the highperforming heat exchangers enhance EER values up to 5,1 (CA version) and even up to5,6 (CA-E version) at Eurovent standars conditions.

Page 135: Products Guide V01 - ParagonEfficient project management thanks to Climaveneta as unique project leader. Complete and specialized Organization Climaveneta qualifies itself for the

133

COOLINGHEATING

r HFCR-134a

SCREWSHELL & TUBESENERGY CLASS

Note:

1 Evaporator water (in/out) = 12/7°C, condenser water (in/out) = 30/35°C, based on Eurovent Standard

2 Evaporator water (in/out): 12/7°C; Condenser water (in/out): 30/35°C; Desuperheater water (in/out): 40/45°C.

3 Evaporator water (in/out) = 12/7°C; Recovery unit water (in/out) = 40/45°C

4 Evaporator water (in/out) = 12/7°C; Condenser water (in/out) = 40/45°C.

5 Sound power on the basis of measurements made in compliance with ISO 9614 and Eurovent 8/1 for Eurovent certified units; in compliance with ISO 3744 for non-certified units.

6 Sound pressure in open field conditions on reflecting surface (directivity factor Q=2), average value on longest side, at 1 m from the outer surface and at 1 m height in relation to the unit supporting base.

7 Unit in standard configuration/execution, without optional accessories

FOCS2-W / CAModels 1301 1401 1601 1801 2101 2401 2701 3001 2802 3202 3602 4202COOLING ONLYCooling capacity (1) kW 306 348 422 477 538 607 689 735 694 844 957 1071Total power input (1) kW 60,5 68,7 83,4 94,4 106 120 136 145 137 167 189 212Condernser heating capacity (1) - - - - - - - - - - - -EER 5,06 5,07 5,06 5,06 5,07 5,07 5,06 5,06 5,05 5,06 5,07 5,06ESEERCOOLING WITH PARTIAL RECOVERY (only -D)Cooling capacity (2) kW 318 361 438 495 558 630 715 762 720 876 993 1112Total power input (2) kW 58,4 66,3 80,5 91,1 102 116 131 140 133 161 182 204Desuperheater heating capacity (2) kW 26,3 29,8 36,2 41 46 52 59,1 63,1 59,7 72,4 82 91,9COOLING WITH TOTAL RECOVERY (only -R)Cooling capacity (3) kW 276 314 376 425 483 546 603 667 625 752 853 964Total power input (3) kW 76,8 87,3 104 118 133 150 166 183 175 209 236 265Heat recovery capacity (3) kW 348 396 474 536 608 687 759 839 790 948 105 1214HEATING ONLY (only -H)Heating capacity (4) kW 348 396 474 536 608 687 759 839 790 948 1075 1214Total power input (4) kW 76,8 87,3 104 118 133 150 166 183 175 209 236 265COP 4,53 4,54 4,54 4,54 4,58 4,59 4,58 4,59 4,52 4,54 4,55 4,58COMPRESSORS No. Compressors/No. Circuits N. 1/1 1/1 1/1 1/1 1/1 1/1 1/1 1/1 2/2 2/2 2/2 2/2NOISE LEVELSSound power (5) dB(A) 97 97 97 97 97 97 99 99 99 99 99 99Sound pressure (6) dB(A) 75 75 75 75 75 75 77 77 77 77 77 77SIZEA (7) mm 3930 3930 3930 3930 3930 3930 3980 3980 4250 4750 4750 4750B (7) mm 900 900 900 900 900 900 900 900 1150 1150 1150 1150H (7) mm 1850 1850 1900 1950 1950 1950 1990 1990 2160 2156 2156 2226Operating weight (7) kg * * * * * * * * * * * *

Models 4502 4802 5402 6002 6303 6603 7203 7803 8103 9003 9004 9604COOLING ONLYCooling capacity (1) kW 1145 1213 1376 1467 1604 1677 1815 1977 2069 2201 2278 2416Total power input (1) kW 226 240 272 290 317 331 359 391 409 435 451 478Condernser heating capacity (1) - - - - - - - - - - - -EER 5,06 5,06 5,05 5,05 5,05 5,06 5,05 5,06 5,06 5,06 5,05 5,05ESEERCOOLING WITH PARTIAL RECOVERY (only -D)Cooling capacity (2) kW 1188 1259 1428 1522 1664 1740 1883 2051 2146 2283 2363 2507Total power input (2) kW 218 231 263 280 306 320 346 377 394 420 435 462Desuperheater heating capacity (2) kW 98,2 104 118 126 138 144 156 170 178 189 196 208COOLING WITH TOTAL RECOVERY (only -R)Cooling capacity (3) kW 1029 1091 1205 1333Total power input (3) kW 283 300 331 366Heat recovery capacity (3) kW 1295 1374 1516 1676HEATING ONLY (only -H)Heating capacity (4) kW 1295 1374 1516 1676 1817 1898 2056 2215 2276 2515 2582 2739Total power input (4) kW 283 300 331 366 398 415 449 484 497 548 564 599COP 4,58 4,58 4,58 4,58 4,57 4,58 4,58 4,58 4,58 4,59 4,58 4,58COMPRESSORS No. Compressors/No. Circuits N. 2/2 2/2 2/2 2/2 3/3 3/3 3/3 3/3 3/3 3/3 4/4 4/4NOISE LEVELSSound power (5) dB(A) 99 99 101 101 102 102 102 102 102 102 102 102Sound pressure (6) dB(A) 77 77 79 79 80 80 80 80 80 80 80 80SIZEA (7) mm 4750 4750 4850 4850 4950 4950 4950 4950 4950 4950 4650 4650B (7) mm 1150 1150 1150 1150 1700 1700 1700 1700 1700 1700 2250 2250H (7) mm 2226 2226 2226 2226 2150 2150 2150 2150 2150 2150 2180 2180Operating weight (7) kg * * * * * * * * * * * *

Page 136: Products Guide V01 - ParagonEfficient project management thanks to Climaveneta as unique project leader. Complete and specialized Organization Climaveneta qualifies itself for the

134

Minimum clearance required1301-9604

Switchboard side mm 1500Cooler water connections side (minimum) mm 900Condenser water connections side mm 3000Condenser water fittings opposite side (minimum) mm 1500

FOCS2-W / CA-EModels 1301 1401 1601 1801 2101 2401 2802 3202 3602 4202 4802COOLING ONLYCooling capacity (1) kW 321 365 442 506 574 649 729 884 1012 1147 1298Total power input (1) kW 57,3 65,1 79,1 90,3 103 116 130 158 180 205 232Condernser heating capacity (1) - - - - - - - - - - -EER 5,60 5,60 5,59 5,61 5,59 5,59 5,60 5,59 5,61 5,59 5,59ESEER 6,49 6,50 6,30 6,40 6,37 6,40 6,66 6,57 6,73 6,64 6,66COOLING WITH PARTIAL RECOVERY (only -D)Cooling capacity (2) kW 322 367 444 509 577 653 733 889 1017 1153 1305Total power input (2) kW 57,2 65,0 78,9 90,1 102 116 130 158 180 205 232Desuperheater heating capacity (2) kW 25,7 29,2 35,5 40,5 46,1 52,2 58,5 71,0 81,0 92,1 104COOLING WITH TOTAL RECOVERY (only -R)Cooling capacity (3) kW 289 328 395 452 657 790 904Total power input (3) kW 73,1 83,1 99,5 114 166 199 227Heat recovery capacity (3) kW 357 407 488 559 813 977 1118HEATING ONLY (only -H)Heating capacity (4) kW 357 407 488 559 638 722 813 977 1118 1275 1443Total power input (4) kW 73,1 83,1 99,5 114 129 146 166 199 227 258 292COP 4,89 4,89 4,91 4,92 4,94 4,94 4,89 4,91 4,92 4,94 4,94COMPRESSORS No. Compressors/No. Circuits N. 1 / 1 1 / 1 1 / 1 1 / 1 1 / 1 1 / 1 2 / 2 2 / 2 2 / 2 2 / 2 2 / 2NOISE LEVELSSound power (5) dB(A) 97 97 97 97 97 97 99 99 99 99 99Sound pressure (6) dB(A) 75 75 75 75 75 75 77 77 77 77 77SIZEA (7) mm 4300 4300 4000 4000 4000 4300 4600 4950 5220 4950 4950B (7) mm 990 990 990 990 990 990 1240 1240 1240 1240 1375H (7) mm 1900 1900 2000 2000 2000 2100 2195 2195 2195 2350 2430Operating weight (7) kg * * * * * * * * * * *

Note:

1 Evaporator water (in/out) = 12/7°C, condenser water (in/out) = 30/35°C, based on Eurovent Standard

2 Evaporator water (in/out): 12/7°C; Condenser water (in/out): 30/35°C; Desuperheater water (in/out): 40/45°C.

3 Evaporator water (in/out) = 12/7°C; Recovery unit water (in/out) = 40/45°C

4 Evaporator water (in/out) = 12/7°C; Condenser water (in/out) = 40/45°C.

5 Sound power on the basis of measurements made in compliance with ISO 9614 and Eurovent 8/1 for Eurovent certified units; in compliance with ISO 3744 for non-certified units.

6 Sound pressure in open field conditions on reflecting surface (directivity factor Q=2), average value on longest side, at 1 m from the outer surface and at 1 m height in relation to the unit supporting base.

7 Unit in standard configuration/execution, without optional accessories

Page 137: Products Guide V01 - ParagonEfficient project management thanks to Climaveneta as unique project leader. Complete and specialized Organization Climaveneta qualifies itself for the

135

Page 138: Products Guide V01 - ParagonEfficient project management thanks to Climaveneta as unique project leader. Complete and specialized Organization Climaveneta qualifies itself for the

136

Main accessoriesIntegral acoustical enclosure (type base or plus)

VPF (Variable Primary Flow) system

Several devices for condensation´s control

Leak detector

Set-up for remote connectivity with ModBus/Echelon/Bacnet protocol cards

FeaturesVERY HIGH EFFICIENCY

Very high efficiency at full and partial load, to top market levels, thanks to adopted technological solutions: large capacity modulation and expanded exchanger, offering minimum running costs of the unit in real working conditions.

DEDICATED VERSIONS

Dedicated versions for different applications: version HC, High Condensing, for dry-cooler or heat pump systems and version LC, Low Condensing, for cooling tower or ground source applications.

HEAT PUMP FUNCTION

Heat pump function water circuit side reversal

EXTREMELY SILENT OPERATION

Extremely silent operation in line with the best on the market, and highly reduced vibrations

LOW INRUSH CURRENTS

Reduced breakaway starting currents thanks to the revolutionary centrifugal compressor

Configurations- base function

H function with heat pump, reversible on hydraulic side

VersionsHC High Condensing

LC Low Condensing

CommandsW3000SE LargeThe W3000 SE Large controller offers advanced functions and algorithms. The keypad is generously sized with full operating status display. The commands and detailed LCD display make access to the units settings easy and safe. These resources allow to consult and intervene on the unit by means of a multi-level menu, with selectable language setting. The diagnostics includes a complete alarm management, with the “black-box” and alarm logging functions for enhanced analysis of the unit operation. For multiple units systems, the regulation of the resources, via optional proprietary devices, can be implemented. Energy metering, for both consumption and capacity, can also be developed. Supervision can be easily developed via proprietary devices or the integration in third party systems by means of the most common protocols as ModBus, Bacnet, Bacnet-over-IP, Echelon LonWorks. Compatibility with the remote keyboard managing up to 10 units. Availability of an internal real time clock for operation scheduling (4-day profiles with 10 hour belts). The regulation features the continuous modulation of capacity by adjustment of the compressor speed. The modulation is based on PID algorithms and referring to the leaving water temperature. This is combined with the management of the compressors status, based on a proportional logic referred to the return temperature. As option (VPF package), the modulation of capacity is integrated with the modulation of the water flow, by means of inverter and dedicated resources for the hydraulic circuit.

Hydronic - chiller

TECS2-W Vision 2.0 0251÷1954

High efficiency chiller, water source

241 - 1949 kWUnit DescriptionIndoor unit for the production of chilled water featuring centrifugal compressors oil-free, with R134a, electronic regulation valve, shell and tube condenser and shell and tube flooded evaporator. Base and supporting structure and panels are of galvanized epoxy powder coated steel with increased thickness. Flexible and reliable unit; it easily adapts itself to different thermal load conditions thanks to the precise thermoregulation together with the use of inverter technology. The compressor is radically innovative: magnetic bearings and digital rotor speed control allow partial load efficiency levels to be reached that were hither to impossible.

Page 139: Products Guide V01 - ParagonEfficient project management thanks to Climaveneta as unique project leader. Complete and specialized Organization Climaveneta qualifies itself for the

137

COOLINGHEATING

r HFCR-134a

CENTRIFUGALSHELL & TUBESENERGY CLASS

Note:

1 Evaporator water (in/out) = 12/7°C, condenser water (in/out) = 30/35°C, based on Eurovent Standard

2 Sound power on the basis of measurements made in compliance with ISO 9614 and Eurovent 8/1 for Eurovent certified units; in compliance with ISO 3744 for non-certified units.

3 Sound pressure in open field conditions on reflecting surface (directivity factor Q=2), average value on longest side, at 1 m from the outer surface and at 1 m height in relation to the unit supporting base.

4 Unit in standard configuration/execution, without optional accessories

TECS2-W Vision 2.0 / LCModels 0511 0912 1012 1353 1453 1854 1954COOLING ONLYCooling capacity (1) kW 488 879 978 1359 1461 1809 1949Total power input (1) kW 93,2 172 186 258 280 344 373Condernser heating capacity (1) - - - - - - -EER 5,24 5,12 5,24 5,27 5,22 5,26 5,23ESEER 9,37 9,19 9,45 9,43 9,41 9,52 9,42COMPRESSORSNo. Compressors/No. Circuits N. 1 / 1 2 / 1 2 / 1 3 / 1 3 / 1 4 / 1 4 / 1NOISE LEVELSSound power (2) dB(A) 95 96 97 97 98 99 99Sound pressure (3) dB(A) 63 64 65 65 66 67 67SIZEA (4) mm 2990 3490 3490 4990 4990 5450 5450B (4) mm 950 1300 1300 1300 1300 1300 1300H (4) mm 1900 1800 1800 1800 1800 1990 1990Operating weight (4) kg - - - - - - -

Note:

1 Evaporator water (in/out) = 12/7°C, condenser water (in/out) = 30/35°C, based on Eurovent Standard

2 Evaporator water (in/out) = 12/7°C; Condenser water (in/out) = 40/45°C.

3 Sound power on the basis of measurements made in compliance with ISO 9614 and Eurovent 8/1 for Eurovent certified units; in compliance with ISO 3744 for non-certified units.

4 Sound pressure in open field conditions on reflecting surface (directivity factor Q=2), average value on longest side, at 1 m from the outer surface and at 1 m height in relation to the unit supporting base.

5 Unit in standard configuration/execution, without optional accessories

TECS2-W Vision 2.0 / HCModels 0251 0311 0351 0411 0512 0612 0712 0812 0913 1053 1213 1414 1614COOLING ONLYCooling capacity (1) kW 241 294 359 405 497 588 716 811 881 1045 1213 1405 1618Total power input (1) kW 46 57 69,2 78,9 94,8 114 139 156 171 203 237 269 316Condernser heating capacity (1) - - - - - - - - - - - - -EER 5,24 5,15 5,19 5,13 5,24 5,16 5,14 5,14 5,15 5,15 5,12 5,23 5,13ESEER 8,70 8,83 8,84 8,95 9,08 9,16 9,04 9,21 9,13 8,96 9,12 9,16 9,20HEATING ONLY (only -H)Heating capacity (2) kW 287 351 439 500 592 703 877 1000 1053 1279 1496 1718 1995Total power input (2) kW 57 70 89 101 118 140 178 203 210 261 304 346 405COP 5,00 5,01 4,95 4,93 5,01 5,02 4,92 4,94 5,02 4,91 4,92 4,96 4,92COMPRESSORSNo. Compressors/No. Circuits N. 1 / 1 1 / 1 1 / 1 1 / 1 2 / 1 2 / 1 2 / 1 2 / 1 3 / 1 3 / 1 3 / 1 4 / 1 4 / 1NOISE LEVELSSound power (3) dB(A) 91 93 92 94 94 95 94 96 96 96 97 97 98Sound pressure (4) dB(A) 59 61 60 62 62 63 62 64 64 64 65 65 66SIZEA (5) mm 2990 2990 2990 2990 3490 3490 3490 3490 4990 4990 4990 5450 5450B (5) mm 950 950 950 950 1300 1300 1300 1300 1300 1300 1300 1300 1300H (5) mm 1900 1900 1900 1900 1800 1800 1800 1800 1800 1800 1800 1990 1990Operating weight (5) kg - - - - - - - - - - - - -

Minimum clearance required0251-0411 0512-0612 0712-1213 1414-1614

Switchboard side mm 1000 1000 1000 1000

Cooler water connections side (minimum)

mm 2500 3000 4000 4500

Condenser water connections side mm 2500 3000 4000 4500Raising points side mm 900 900 900 900

Page 140: Products Guide V01 - ParagonEfficient project management thanks to Climaveneta as unique project leader. Complete and specialized Organization Climaveneta qualifies itself for the

138

Main accessoriesRemote keyboard (distance to 200m and to 500m)

Set-up for remote connectivity with ModBus, Echelon LonTalk, Bacnet protocol board

Acoustical enclosure to reduce the noise emissions.

Rubber anti-vibration mounting kit

FeaturesREFRIGERANT GAS R410A

The use of R410A has resulted in units offering better energy efficiency in full respect for the environment (ODP = 0)UNIT DESIGNED FOR COMBINATION WITH REMOTE CONDENSERCompact units, designed for residential- and commercial air-conditioning systems

INTEGRAL CONTROL AND ADJUSTMENT

The condenserless unit comes complete with built-in microprocessor control with possible connection to the condenser.

INTEGRATED HYDRONIC MODULE

The built-in hydronic module already contains the main water circuit components; it is available with single or double pump configuration, with low or high head.

VersionsB base version

CommandsW3000 Base / W3000SE CompactThe controller can be chosen as: - W3000 Base: keypad and LED display - W3000SE Compact: the keypad features an easy-to-use interface and a complete LCD display, allowing to consult and intervene on the unit by means of a multi-level menu, with selectable language setting. The diagnostics includes a complete alarm management, with the “black-box” and alarm logging functions for enhanced analysis of the unit operation. Compatibility with the remote keyboard managing up to 10 units. Availability of an internal real time clock for operation scheduling (4-day profiles with 10 hour belts). Common features: The regulation is based on the exclusive QuickMind algorithm, including self-adaptive control logics, beneficial in low water content systems. As alternatives the proportional- or proportional-integral regulations are also available. For multiple units systems, the regulation of the resources, via optional proprietary devices, can be implemented. Energy metering, for both consumption and capacity, can also be developed. Supervision can be easily developed via proprietary devices or the integration in third party systems by means of the most common protocols as ModBus, Bacnet, Bacnet-over-IP, Echelon LonWorks.

Hydronic - chiller

NECS-ME 0152÷1604

Condenserless chiller

39,5 - 432 kWUnit DescriptionIndoor unit for the production of chilled water that may be connected to a remote condenser with hermetic rotary scroll compressors working with R410A, braze-welded plate-type exchanger and thermal expansion valve. Panels and base in hot-dip galvanised sheet steel with paint finish.

Page 141: Products Guide V01 - ParagonEfficient project management thanks to Climaveneta as unique project leader. Complete and specialized Organization Climaveneta qualifies itself for the

139

Minimum clearance required0152-0612 0604-1604

Switchboard side mm 800 1000Cooler water connections side (minimum) mm 600 1000Unit's side mm 600 800

Switchboard opposite side mm 600 1000

Note:

1 Evaporator water (in/out) = 12/7°C; Condensation temperature = 47°C.

2 Sound power on the basis of measurements made in compliance with ISO 9614 and Eurovent 8/1 for Eurovent certified units; in compliance with ISO 3744 for non-certified units.

3 Sound pressure in open field conditions on reflecting surface. Condensing coil side average value at 1 metre from the surface and at 1 m height in relation to the unit supporting base.

Models 0612 0604 0704 0804 0904 1004 1104 1204 1404 1604COOLINGCooling capacity (1) kW 170 161 186 207 235 263 301 339 387 432Compressors power input (1) kW 48,9 46,9 53,7 60,6 67,9 75,2 86,5 97,8 111 124Remote condenser capacity (1) kW 3,47 3,43 3,46 3,42 3,47 3,50 3,47 3,47 3,49 3,48COMPRESSORSNo. Compressors/No. Circuits N. 2 / 1 4 / 2 4 / 2 4 / 2 4 / 2 4 / 2 4 / 2 4 / 2 4 / 2 4 / 2NOISE LEVELSSound power (2) dB(A) 79 86 87 88 89 90 91 91 91 91Sound pressure (3) dB(A) 47 54 55 56 57 58 59 59 59 59SIZEA mm 1310 2227 2227 2227 2227 2227 2227 2227 2227 2227B mm 893 1020 1020 1020 1020 1020 1020 1020 1020 1020H mm 1496 1780 1780 1780 1780 1780 1780 1780 1780 1780Operating weight kg 755 700 950 1125 1185 1250 1330 1370 1430 1480

NECS-ME / BModels 0152 0182 0202 0252 0262 0302 0352 0412 0452 0512 0552COOLINGCooling capacity (1) kW 39,5 45,8 53,6 60,5 67,4 80,2 92,8 105 117 131 151Compressors power input (1) kW 12 13,5 15,7 18,1 20 23,4 26,9 30,3 33,9 37,6 43,3Remote condenser capacity (1) kW 3,29 3,39 3,41 3,34 3,37 3,43 3,45 3,45 3,46 3,49 3,48COMPRESSORSNo. Compressors/No. Circuits N. 2 / 1 2 / 1 2 / 1 2 / 1 2 / 1 2 / 1 2 / 1 2 / 1 2 / 1 2 / 1 2 / 1NOISE LEVELSSound power (2) dB(A) 73 74 74 74 75 76 77 77 77 78 79Sound pressure (3) dB(A) 41 42 42 42 43 44 45 45 45 46 47SIZEA mm 1130 1130 1130 1130 1130 1310 1310 1310 1310 1310 1310B mm 669 669 669 669 669 893 893 893 893 893 893H mm 1255 1255 1255 1255 1255 1496 1496 1496 1496 1496 1496Operating weight kg 270 280 290 295 300 410 500 585 615 645 680

COOLING

r HFCR-410A

SCROLLPLATES

H

BA

H

B A

Page 142: Products Guide V01 - ParagonEfficient project management thanks to Climaveneta as unique project leader. Complete and specialized Organization Climaveneta qualifies itself for the

140

Main accessoriesSoft start

Set-up for remote connectivity with ModBus, Echelon LonTalk, Trend, Bacnet protocol board.

Remote keyboard (distance to 200m and to 500m)

Electronic expansion valve

Integral acoustical enclosure (type base or plus)

FeaturesCOMPACTNESS

Compactness in terms of overall size and weight, helping installation and working on site

ADAPTABILITY

Adaptability at the buildings cooling request thanks to the continuous capacity regulation, assured by sophisticated controls logic

EXTENSIVE RANGE OF OPERATION

Extensive range of operation with remote condenser operating up to 46°C air temperature

SILENT OPERATION

Silent operation thanks to the accurate units design. Optional integral acoustic enclosure, further reduces the sound level beyond the best on market

VersionsB base version

CommandsW3000SE CompactThe W3000 SE Large controller offers advanced functions and algorithms. The keypad is generously sized with full operating status display. The commands and detailed LCD display make access to the units settings easy and safe. These resources allow to consult and intervene on the unit by means of a multi-level menu, with selectable language setting. The diagnostics includes a complete alarm management, with the “black-box” and alarm logging functions for enhanced analysis of the unit operation. For multiple units systems, the regulation of the resources, via optional proprietary devices, can be implemented. Energy metering, for both consumption and capacity, can also be developed. Supervision can be easily developed via proprietary devices or the integration in third party systems by means of the most common protocols as ModBus, Bacnet, Bacnet-over-IP, Echelon LonWorks. Compatibility with the remote keyboard managing up to 10 units. Availability of an internal real time clock for operation scheduling (4-day profiles with 10 hour belts). The regulation features the continuous modulation of capacity, based on a dynamic dead band and referring to the leaving water temperature. As alternative, step-wise regulation is also available, referred to the return water temperature with selectable proportional- or proportional-integral logic.

Hydronic - chiller

FOCS-ME 0401÷1902

Condenserless chiller

79,2 - 410 kWUnit DescriptionIndoor unit for the production of chilled water combined with a remote condenser, with semi-hermetic screw compressors optimized for R134a, shell and tube evaporator designed by Climaveneta and thermostatic expansion valve. Base and supporting structure and panels are of galvanized epoxy powder coated steel with increased thickness. Flexible and reliable unit; it easily adapts itself to different thermal load conditions thanks to the precise thermoregulation. The high performances level is achieved thanks to the accurate sizing of all internal components.

Page 143: Products Guide V01 - ParagonEfficient project management thanks to Climaveneta as unique project leader. Complete and specialized Organization Climaveneta qualifies itself for the

141

Minimum clearance required0401-1902

Switchboard side mm 1000Cooler water connections side (minimum)

mm 620

Compressor outlet connection side mm 500Compressor outlet connection opposite side

mm 500

Note:

1 Evaporator water (in/out) = 12/7°C; Condensation temperature = 47°C.

2 Sound power on the basis of measurements made in compliance with ISO 9614 and Eurovent 8/1 for Eurovent certified units; in compliance with ISO 3744 for non-certified units.

3 Sound pressure in open field conditions on reflecting surface (directivity factor Q=2), average value on longest side, at 1 m from the outer surface and at 1 m height in relation to the unit supporting base.

Models 0802 1002 1102 1302 1502 1702 1902COOLINGCooling capacity (1) kW 162 200 230 273 312 360 410 Compressors power input (1) kW 45,6 56,0 64,6 75,3 85,0 97,7 113 Remote condenser capacity (1) kW 208 256 295 348 397 458 523 COMPRESSORSNo. Compressors/No. Circuits N. 2/2 2/2 2/2 2/2 2/2 2/2 2/2 NOISE LEVELSSound power (2) dB(A) 94 95 97 97 97 97 97 Sound pressure (3) dB(A)SIZEA mm 2890 2890 3016 3277 3277 3292 3362 B mm 1081 1081 1081 1081 1081 1081 1081 H mm 1430 1430 1480 1580 1580 1590 1700 Operating weight kg 1280 1290 1680 1970 1990 2010 2300

FOCS-ME / BModels 0401 0501 0551 0651 0751 0851 0951COOLINGCooling capacity (1) kW 79,2 98,2 119 135 151 181 203 Compressors power input (1) kW 22,7 27,9 32,5 37,6 42,3 48,9 56,5 Remote condenser capacity (1) kW 102 126 152 173 193 230 260 COMPRESSORSNo. Compressors/No. Circuits N. 1/1 1/1 1/1 1/1 1/1 1/1 1/1 NOISE LEVELSSound power (2) dB(A) 91 92 94 94 94 94 94 Sound pressure (3) dB(A) SIZEA mm 2024 2330 2400 2400 2400 2947 2947 B mm 880 880 880 880 880 880 880 H mm 1300 1300 1490 1490 1490 1490 1500 Operating weight kg 720 750 1040 1060 1060 1130 1150

COOLING

r HFCR-134a

SCREWSHELL & TUBES

H

BA

Page 144: Products Guide V01 - ParagonEfficient project management thanks to Climaveneta as unique project leader. Complete and specialized Organization Climaveneta qualifies itself for the

142

Main accessoriesIntegral acoustical enclosure (type base or plus)

Electronic expansion valve

Soft start

Set-up for remote connectivity with ModBus, Echelon LonTalk, Trend, Bacnet protocol board.

Remote keyboard (distance to 200m and to 500m)

FeaturesCOMPACTNESS

Compactness in terms of overall size and weight, helping installation and working on site

ADAPTABILITY

Adaptability at the buildings cooling request thanks to the continuous capacity regulation, assured by sophisticated controls logic

EXTENSIVE RANGE OF OPERATION

Extensive range of operation with remote condenser operating up to 46°C air temperature

SILENT OPERATION

Silent operation thanks to the accurate units design. Optional integral acoustic enclosure, further reduces the sound level beyond the best on market

VersionsB base version

Hydronic - chiller

FOCS-ME 1001÷9604

Condenserless chiller

219 - 2240 kWUnit DescriptionIndoor unit for the production of chilled water combined with a remote condenser, with semi-hermetic screw compressors optimized for R134a, shell and tube evaporator designed by Climaveneta and thermostatic expansion valve. Base and supporting structure and panels are of galvanized epoxy powder coated steel with increased thickness. Flexible and reliable unit; it easily adapts itself to different thermal load conditions thanks to the precise thermoregulation. The high performances level is achieved thanks to the accurate sizing of all internal components.

CommandsW3000SE CompactThe W3000 SE Large controller offers advanced functions and algorithms. The keypad is generously sized with full operating status display. The commands and detailed LCD display make access to the units settings easy and safe. These resources allow to consult and intervene on the unit by means of a multi-level menu, with selectable language setting. The diagnostics includes a complete alarm management, with the “black-box” and alarm logging functions for enhanced analysis of the unit operation. For multiple units systems, the regulation of the resources, via optional proprietary devices, can be implemented. Energy metering, for both consumption and capacity, can also be developed. Supervision can be easily developed via proprietary devices or the integration in third party systems by means of the most common protocols as ModBus, Bacnet, Bacnet-over-IP, Echelon LonWorks. Compatibility with the remote keyboard managing up to 10 units. Availability of an internal real time clock for operation scheduling (4-day profiles with 10 hour belts). The regulation features the continuous modulation of capacity, based on a dynamic dead band and referring to the leaving water temperature. As alternative, step-wise regulation is also available, referred to the return water temperature with selectable proportional- or proportional-integral logic.

Page 145: Products Guide V01 - ParagonEfficient project management thanks to Climaveneta as unique project leader. Complete and specialized Organization Climaveneta qualifies itself for the

143

Minimum clearance required1001-9604

Switchboard side mm 1000Cooler water connections side (minimum)

mm 620

Compressor outlet connection side mm 500Compressor outlet connection opposite side

mm 500

Note:

1 Evaporator water (in/out) = 12/7°C; Condensation temperature = 47°C.

2 Sound power on the basis of measurements made in compliance with ISO 9614 and Eurovent 8/1 for Eurovent certified units; in compliance with ISO 3744 for non-certified units.

3 Sound pressure in open field conditions on reflecting surface (directivity factor Q=2), average value on longest side, at 1 m from the outer surface and at 1 m height in relation to the unit supporting base.

Models 5414 5904 6404 6804 7204 7804 8404 9004 9604COOLINGCooling capacity (1) kW 1348 1434 1548 1660 1769 1886 2001 2121 2240 Compressors power input (1) kW 342 373 406 439 472 501 530 555 580 Remote condenser capacity (1) kW 1690 1807 1954 2099 2241 2387 2531 2676 2820 COMPRESSORSNo. Compressors/No. Circuits N. 4/4 4/4 4/4 4/4 4/4 4/4 4/4 4/4 4/4 NOISE LEVELSSound power (2) dB(A) 102 102 102 102 102 102 102 102 102 Sound pressure (3) dB(A) SIZEA mm 4500 4500 4500 4500 4500 4500 4500 4500 4500 B mm 2250 2250 2250 2250 2250 2250 2250 2250 2250 H mm 2000 2000 2000 2000 2000 2000 2000 2000 2000 Operating weight kg 7560 8400 9980 10010 10020 10190 10350 10420 10480

Models 2702 3202 3602 4202 4502 4802 5003 5203 5403COOLINGCooling capacity (1) kW 674 759 885 1000 1061 1120 1184 1251 1304 Compressors power input (1) kW 171 202 236 265 277 290 320 337 353 Remote condenser capacity (1) kW 845 916 1121 1265 1338 1410 1504 1588 1657 COMPRESSORSNo. Compressors/No. Circuits N. 2/2 2/2 2/2 2/2 2/2 2/2 3/3 3/3 3/3 NOISE LEVELSSound power (2) dB(A) 99 99 99 99 99 99 101 101 101 Sound pressure (3) dB(A)SIZEA mm 4500 4500 4500 4500 4500 4500 4425 4425 4425 B mm 1150 1150 1150 1150 1150 1150 1700 1700 1700 H mm 2000 2000 2000 2000 2000 2000 1900 1900 1900 Operating weight kg 3730 4600 5050 5220 5250 5280 6810 6840 6850

FOCS-ME / BModels 1001 1201 1301 1351 1601 1801 2002 2402 2602COOLINGCooling capacity (1) kW 219 262 295 333 389 445 419 516 591 Compressors power input (1) kW 59,7 69,7 77,5 85,4 101 118 114 139 155 Remote condenser capacity (1) kW 279 332 373 418 490 563 533 655 746 COMPRESSORSNo. Compressors/No. Circuits N. 1/1 1/1 1/1 1/1 1/1 1/1 2/2 2/2 2/2 NOISE LEVELSSound power (2) dB(A) 94 97 97 97 97 97 97 99 99 Sound pressure (3) dB(A)SIZEA mm 2835 3120 3120 3120 3530 3530 3730 3730 4500 B mm 900 900 900 900 900 900 1150 1150 1150 H mm 1800 1800 1800 1800 1950 1950 2000 2000 2000 Operating weight kg 1380 1870 1910 1920 2640 2650 2750 3420 3710

COOLING

r HFCR-134a

SCREWSHELL & TUBES

H

BA

Page 146: Products Guide V01 - ParagonEfficient project management thanks to Climaveneta as unique project leader. Complete and specialized Organization Climaveneta qualifies itself for the

144

RONIC - RDR RR

Page 147: Products Guide V01 - ParagonEfficient project management thanks to Climaveneta as unique project leader. Complete and specialized Organization Climaveneta qualifies itself for the

145

EVERSIBLEhydronic - reversible

hyd

ron

icre

vers

ible

Page 148: Products Guide V01 - ParagonEfficient project management thanks to Climaveneta as unique project leader. Complete and specialized Organization Climaveneta qualifies itself for the

146

Main accessoriesSet-up for remote connectivity with ModBus/Echelon/Bacnet protocol cards

Remote keyboard (distance to 200m and to 500m)

Soft starters

LT kit for working down to -10°C in heat pump mode

Rubber anti-vibration mounting kit. Spring anti-vibration mounting kit (4 compressors models only)

FeaturesREFRIGERANT GAS R410A

The use of R410A has resulted in units offering better energy efficiency in full respect for the environment (ODP = 0)

TOTAL VERSATILITY

Climaveneta is the only company offering units with Scroll compressors in 5 versions and 2 different configurations designed to satisfy all service system and application requirementsSTANDARD SUPPLY WITH WATER FILTER ALREADY INSTALLEDThe water filter is already installed as standard supply on all units, including those without hydronic kit. This simplifies installation procedures, while ensuring maximum working reliability

INTEGRATED HYDRONIC MODULE

The incorporated hydronic unit already contains the main water circuit components; it is available in various configurations with one or two pumps with high or low head and the buffer tank

Configurations- base function

D partial condensing heat recovery function

VersionsB base version

HL low noise, high efficiency, high outdoor temperature version

HT high efficiency, high outdoor temperature version

LN low noise version

SL super-low noise version

CommandsW3000 Base / W3000SE CompactThe controller can be chosen as: - W3000 Base: keypad and LED display - W3000SE Compact: the keypad features an easy-to-use interface and a complete LCD display, allowing to consult and intervene on the unit by means of a multi-level menu, with selectable language setting. The diagnostics includes a complete alarm management, with the “black-box” and alarm logging functions for enhanced analysis of the unit operation. Compatibility with the remote keyboard managing up to 10 units. Availability of an internal real time clock for operation scheduling (4-day profiles with 10 hour belts). Common features: The regulation is based on the exclusive QuickMind algorithm, including self-adaptive control logics, beneficial in low water content systems. As alternatives the proportional- or proportional-integral regulations are also available. For multiple units systems, the regulation of the resources, via optional proprietary devices, can be implemented. Energy metering, for both consumption and capacity, can also be developed. Supervision can be easily developed via proprietary devices or the integration in third party systems by means of the most common protocols as ModBus, Bacnet, Bacnet-over-IP, Echelon LonWorks. The defrost adopts a proprietary self-adaptive logic, which features the monitoring of numerous operational parameters. This allows to reduce the number and duration of the defrost cycles, with a benefit for the overall energy efficiency.

Hydronic - reversible

NECS-N 0152÷1204

Reversible unit, air source for outdoor installation

35,8 - 322 kWUnit DescriptionOutdoor unit with heat pump for the production of chilled/hot water with hermetic rotary scroll compressors dedicated to the use of R410A, axial fans, braze-welded plate-type exchanger and thermal expansion valve. External panels in pre-clad sheet steel (simil Pereluman) and base in galvanised steel with paint finish. The range includes the single-circuit two-compressor versions and the dual circuit four-compressor versions.

Page 149: Products Guide V01 - ParagonEfficient project management thanks to Climaveneta as unique project leader. Complete and specialized Organization Climaveneta qualifies itself for the

147

Note:

1 Evaporator water (in/out) = 12/7°C; Condenser air (in) = 35°C.

2 Condenser water (in/out) = 40/45°C; evaporator air (in) = 7°C - r.h. 87%.

3 Evaporator water (in/out) = 12/7°C; Condenser air (in) = 35°C. Desuperheater water (in/out) = 40/45°C.

4 Sound power on the basis of measurements made in compliance with ISO 9614 and Eurovent 8/1 for Eurovent certified units; in compliance with ISO 3744 for non-certified units.

5 Average sound pressure level, at 10m distance, unit in a free field on a reflective surface; non-binding value obtained from the sound power level.

6 Unit in standard configuration/execution, without optional accessories

Models 0612 0504 0524 0604 0704 0804 0904 1004 1104 1204COOLING ONLYCooling capacity (1) kW 151 111 129 147 166 189 211 240 277 311Total power input (1) kW 59 43,7 54 60 68,9 75,9 85,1 95,6 107 120EER 2,56 2,54 2,39 2,45 2,41 2,49 2,48 2,51 2,58 2,58ESEER 3,99 3,99 3,39 3,57 3,64 3,80 3,88 3,68 3,84 3,93HEATING ONLYHeating capacity (2) kW 173 127 145 167 185 209 234 267 306 344Total power input (2) kW 54,6 43,6 52,7 58 64,7 72,1 79,9 92,1 104 116COP 3,17 2,91 2,75 2,88 2,86 2,90 2,93 2,90 2,94 2,96COOLING WITH PARTIAL RECOVERYCooling capacity (3) kW 156 116 134 152 172 196 219 249 287 322Total power input (3) kW 56,9 42,5 52,4 58,1 66,8 73,4 82,5 92,7 104 117Desuperheater heating capacity (3) kW 50,3 35,4 40,7 46 54 60,1 68,6 74,1 84,6 96,3COMPRESSORSNo. Compressors/No. Circuits N. 2/1 4/2 4/2 4/2 4/2 4/2 4/2 4/2 4/2 4/2NOISE LEVELSSound power (4) dB(A) 87 91 92 92 92 92 93 94 95 95Sound pressure (5) dB(A) 55 59 60 60 60 60 61 62 63 63SIZEA (6) mm 3245 3110 3110 3110 3110 3110 4110 4110 4110 4110B (6) mm 1120 2220 2220 2220 2220 2220 2220 2220 2220 2220H (6) mm 1620 1700 1700 1700 2150 2150 2150 2150 2150 2150Operating weight (6) kg 1030 1380 1570 1750 1900 2080 2270 2410 2540 2700

NECS-N / BModels 0152 0182 0202 0252 0302 0352 0412 0452 0512 0552COOLING ONLYCooling capacity (1) kW 37,7 42,8 47,9 57,5 72 82,5 93,9 107 120 138Total power input (1) kW 13,6 15,7 19,2 20,4 28 32 36 39,9 44 50,6EER 2,77 2,73 2,49 2,82 2,57 2,58 2,61 2,68 2,73 2,73ESEER 4,04 4,08 4,03 4 3,95 4,06 3,92 4,09 4,04 4,18HEATING ONLYHeating capacity (2) kW 42,9 48,1 54,2 65,2 81 93,5 105 121 136 157Total power input (2) kW 14,2 15,6 18,1 21,2 26,1 29,8 33,8 38,1 42,4 48,6COP 3,02 3,08 2,99 3,08 3,10 3,14 3,11 3,18 3,21 3,23COOLING WITH PARTIAL RECOVERYCooling capacity (3) kW 39,1 44,4 49,7 59,7 74,7 85,6 97,4 111 125 143Total power input (3) kW 13,1 15,1 18,5 19,7 27,1 30,9 34,8 38,5 42,5 48,7Desuperheater heating capacity (3) kW 11,2 13,1 16,2 16,9 23,7 27,2 30,3 33,8 37 42,7COMPRESSORSNo. Compressors/No. Circuits N. 2/1 2/1 2/1 2/1 2/1 2/1 2/1 2/1 2/1 2/1NOISE LEVELSSound power (4) dB(A) 84 84 84 84 85 86 86 86 87 87Sound pressure (5) dB(A) 52 52 52 52 53 54 54 54 55 55SIZEA (6) mm 1695 1695 1695 2195 2195 2195 2745 2745 3245 3245B (6) mm 1120 1120 1120 1120 1120 1120 1120 1120 1120 1120H (6) mm 1420 1420 1420 1420 1420 1420 1420 1420 1620 1620Operating weight (6) kg 400 410 420 500 630 690 770 850 950 1020

COOLINGHEATING

r HFCR-410A

SCROLLAXIALPLATES

Page 150: Products Guide V01 - ParagonEfficient project management thanks to Climaveneta as unique project leader. Complete and specialized Organization Climaveneta qualifies itself for the

148

Note:

1 Evaporator water (in/out) = 12/7°C; Condenser air (in) = 35°C.

2 Condenser water (in/out) = 40/45°C; evaporator air (in) = 7°C - r.h. 87%.

3 Evaporator water (in/out) = 12/7°C; Condenser air (in) = 35°C. Desuperheater water (in/out) = 40/45°C.

4 Sound power on the basis of measurements made in compliance with ISO 9614 and Eurovent 8/1 for Eurovent certified units; in compliance with ISO 3744 for non-certified units.

5 Average sound pressure level, at 10m distance, unit in a free field on a reflective surface; non-binding value obtained from the sound power level.

6 Unit in standard configuration/execution, without optional accessories

NECS-N / HTModels 0504 0524 0604 0704 0804 0904 1004 1104 1204COOLING ONLYCooling capacity (1) kW 117 134 149 172 198 219 248 287 322Total power input (1) kW 45,5 51,3 58,4 65,7 75,3 84,9 91,5 102 118EER 2,57 2,61 2,55 2,62 2,63 2,58 2,71 2,79 2,71ESEER 3,42 3,53 3,64 3,77 3,57 3,60 3,82 3,98 3,80HEATING ONLYHeating capacity (2) kW 134 150 167 191 220 244 274 315 357Total power input (2) kW 48,2 53 58 65,2 76,9 84,7 92,3 104 121COP 2,78 2,83 2,88 2,93 2,86 2,88 2,97 3,02 2,95COOLING WITH PARTIAL RECOVERYCooling capacity (3) kW 121 139 155 178 205 228 257 297 334Total power input (3) kW 44,1 49,8 56,8 63,7 73,1 82,7 88,9 99,6 115Desuperheater heating capacity (3) kW 33 38,3 44,8 51,1 56 64,8 70,6 80,5 91,2COMPRESSORSNo. Compressors/No. Circuits N. 4/2 4/2 4/2 4/2 4/2 4/2 4/2 4/2 4/2NOISE LEVELSSound power (4) dB(A) 92 92 92 92 94 94 94 97 97Sound pressure (5) dB(A) 60 60 60 60 62 62 62 64 65SIZEA (6) mm 3110 3110 3110 3110 4110 4110 4110 5110 5110B (6) mm 2220 2220 2220 2220 2220 2220 2220 2220 2220H (6) mm 1700 2150 2150 2150 2150 2150 2150 2150 2150Operating weight (6) kg 1460 1700 1840 1980 2310 2370 2520 2800 2940

Note:

1 Evaporator water (in/out) = 12/7°C; Condenser air (in) = 35°C.

2 Condenser water (in/out) = 40/45°C; evaporator air (in) = 7°C - r.h. 87%.

3 Evaporator water (in/out) = 12/7°C; Condenser air (in) = 35°C. Desuperheater water (in/out) = 40/45°C.

4 Sound power on the basis of measurements made in compliance with ISO 9614 and Eurovent 8/1 for Eurovent certified units; in compliance with ISO 3744 for non-certified units.

5 Average sound pressure level, at 10m distance, unit in a free field on a reflective surface; non-binding value obtained from the sound power level.

6 Unit in standard configuration/execution, without optional accessories

NECS-N / HLModels 0504 0524 0604 0704 0804 0904 1004 1104 1204COOLING ONLYCooling capacity (1) kW 113 129 142 163 190 209 236 273 307Total power input (1) kW 43,8 51 58,9 67,4 73,9 84,6 92,6 103 119EER 2,58 2,53 2,41 2,42 2,57 2,47 2,55 2,63 2,57ESEER 3,75 3,81 3,78 3,91 3,79 3,81 3,92 4,11 3,91HEATING ONLYHeating capacity (2) kW 128 144 159 181 211 233 261 303 340Total power input (2) kW 44,3 49,2 53,9 60,9 71 78,7 86,4 98,7 112COP 2,89 2,93 2,95 2,97 2,97 2,96 3,02 3,07 3,01COOLING WITH PARTIAL RECOVERYCooling capacity (3) kW 117 133 148 169 197 217 245 283 318Total power input (3) kW 42,3 49,1 57,1 64,9 71,6 82,2 89,4 101 116Desuperheater heating capacity (3) kW 34,7 41 48,3 55,6 59,6 69,4 76 86,4 98,1COMPRESSORSNo. Compressors/No. Circuits N. 4/2 4/2 4/2 4/2 4/2 4/2 4/2 4/2 4/2NOISE LEVELSSound power (4) dB(A) 86 86 86 86 88 88 88 90 91Sound pressure (5) dB(A) 54 54 54 54 56 56 56 58 59SIZEA (6) mm 3110 3110 3110 3110 4110 4110 4110 5110 5110B (6) mm 2220 2220 2220 2220 2220 2220 2220 2220 2220H (6) mm 1700 2150 2150 2150 2150 2150 2150 2150 2150Operating weight (6) kg 1460 1700 1840 1980 2310 2370 2520 2800 2940

Page 151: Products Guide V01 - ParagonEfficient project management thanks to Climaveneta as unique project leader. Complete and specialized Organization Climaveneta qualifies itself for the

149

Note:

1 Evaporator water (in/out) = 12/7°C; Condenser air (in) = 35°C.

2 Condenser water (in/out) = 40/45°C; evaporator air (in) = 7°C - r.h. 87%.

3 Evaporator water (in/out) = 12/7°C; Condenser air (in) = 35°C. Desuperheater water (in/out) = 40/45°C.

4 Sound power on the basis of measurements made in compliance with ISO 9614 and Eurovent 8/1 for Eurovent certified units; in compliance with ISO 3744 for non-certified units.

5 Average sound pressure level, at 10m distance, unit in a free field on a reflective surface; non-binding value obtained from the sound power level.

6 Unit in standard configuration/execution, without optional accessories

Models 0612 0504 0524 0604 0704 0804 0904 1004 1104 1204COOLING ONLYCooling capacity (1) kW 143 103 123 141 156 177 199 227 261 291Total power input (1) kW 62,7 46,2 53,5 60 70,3 78,3 87,7 96,2 110 125EER 2,28 2,23 2,30 2,35 2,22 2,26 2,27 2,36 2,37 2,32ESEER 3,76 3,89 3,66 3,74 3,78 3,77 3,89 3,76 3,92 3,86HEATING ONLYHeating capacity (2) kW 169 122 138 158 176 198 225 254 290 324Total power input (2) kW 54,2 41,5 48,9 53,7 60,7 67,8 75,5 86,1 98 110COP 3,12 2,94 2,82 2,94 2,90 2,92 2,98 2,95 2,96 2,94COOLING WITH PARTIAL RECOVERYCooling capacity (3) kW 148 107 128 146 162 184 207 236 270 302Total power input (3) kW 60,6 44,7 51,8 58 68,2 75,9 84,9 93,4 107 121Desuperheater heating capacity (3) kW 53,8 39,2 43,5 49,2 58,7 65,7 74,1 79,7 92 105COMPRESSORSNo. Compressors/No. Circuits N. 2/1 4/2 4/2 4/2 4/2 4/2 4/2 4/2 4/2 4/2NOISE LEVELSSound power (4) dB(A) 84 85 86 86 86 86 87 88 89 89Sound pressure (5) dB(A) 52 53 54 54 54 54 55 56 57 57SIZEA (6) mm 3245 3110 3110 3110 3110 3110 4110 4110 4110 4110B (6) mm 1120 2220 2220 2220 2220 2220 2220 2220 2220 2220H (6) mm 1620 1700 1700 1700 2150 2150 2150 2150 2150 2150Operating weight (6) kg 1030 1380 1570 1750 1900 2080 2270 2410 2540 2700

NECS-N / LNModels 0152 0182 0202 0252 0302 0352 0412 0452 0512 0552COOLING ONLYCooling capacity (1) kW 35,8 41,6 48 54,6 73,2 83,5 93,9 103 119 132Total power input (1) kW 14,2 16 19,1 21,4 27,2 31,9 36 41,5 44,6 53,4EER 2,52 2,60 2,51 2,55 2,69 2,62 2,61 2,48 2,67 2,47ESEER 4,09 4,16 4,03 4,02 4,08 3,96 3,94 3,93 3,99 3,97HEATING ONLYHeating capacity (2) kW 41,8 48,2 54,1 63,6 84,1 96,2 109 121 138 154Total power input (2) kW 13,8 15,2 18,1 20,7 26,1 30,4 34,2 36,2 42,6 48,3COP 3,02 3,17 2,99 3,07 3,22 3,16 3,19 3,34 3,24 3,19COOLING WITH PARTIAL RECOVERYCooling capacity (3) kW 37,1 43,1 49,8 56,7 75,9 86,7 97,4 107 123 137Total power input (3) kW 13,8 15,5 18,4 20,6 26,3 30,9 34,8 40,2 43,1 51,6Desuperheater heating capacity (3) kW 12,2 13,7 16,1 18,2 23,1 26,7 30,3 35,3 37,5 45,4COMPRESSORSNo. Compressors/No. Circuits N. 2/1 2/1 2/1 2/1 2/1 2/1 2/1 2/1 2/1 2/1NOISE LEVELSSound power (4) dB(A) 79 79 80 80 81 83 83 83 84 84Sound pressure (5) dB(A) 47 47 48 48 49 51 51 51 52 52SIZEA (6) mm 1695 1695 2195 2195 2745 2745 2745 2745 3245 3245B (6) mm 1120 1120 1120 1120 1120 1120 1120 1120 1120 1120H (6) mm 1420 1420 1420 1420 1420 1620 1620 1620 1620 1620Operating weight (6) kg 400 420 460 500 710 770 830 880 990 1020

Page 152: Products Guide V01 - ParagonEfficient project management thanks to Climaveneta as unique project leader. Complete and specialized Organization Climaveneta qualifies itself for the

150

Minimum clearance required0504-1204 0152-0612

Switchboard side mm 1100 600Switchboard opposite side mm 1100 600Condensation coil side mm 2000 1000

Note:

1 Evaporator water (in/out) = 12/7°C; Condenser air (in) = 35°C.

2 Condenser water (in/out) = 40/45°C; evaporator air (in) = 7°C - r.h. 87%.

3 Evaporator water (in/out) = 12/7°C; Condenser air (in) = 35°C. Desuperheater water (in/out) = 40/45°C.

4 Sound power on the basis of measurements made in compliance with ISO 9614 and Eurovent 8/1 for Eurovent certified units; in compliance with ISO 3744 for non-certified units.

5 Average sound pressure level, at 10m distance, unit in a free field on a reflective surface; non-binding value obtained from the sound power level.

6 Unit in standard configuration/execution, without optional accessories

NECS-N / SLModels 0504 0524 0604 0704 0804 0904 1004 1104 1204COOLING ONLYCooling capacity (1) kW 108 124 141 159 183 201 225 261 294Total power input (1) kW 45 52,1 58,3 67,7 75,3 87,4 95,3 108 123EER 2,40 2,38 2,42 2,35 2,43 2,30 2,36 2,41 2,38ESEER 3,84 3,93 3,98 4,05 3,87 3,88 3,93 4,13 3,93HEATING ONLYHeating capacity (2) kW 125 140 158 178 205 226 253 295 330Total power input (2) kW 42,8 47,5 52,2 59,5 68,6 76,1 83,8 96,1 110COP 2,92 2,95 3,03 2,99 2,99 2,97 3,02 3,07 3COOLING WITH PARTIAL RECOVERYCooling capacity (3) kW 112 128 146 165 190 208 234 271 305Total power input (3) kW 43,5 50,3 56,3 65,4 73 84,4 92,3 105 119Desuperheater heating capacity (3) kW 37 43,3 48,9 57,3 62,7 73,3 80,6 92 104COMPRESSORSNo. Compressors/No. Circuits N. 4/2 4/2 4/2 4/2 4/2 4/2 4/2 4/2 4/2NOISE LEVELSSound power (4) dB(A) 82 82 82 82 83 83 83 85 86Sound pressure (5) dB(A) 50 50 50 50 51 51 51 53 54SIZEA (6) mm 3110 3110 3110 3110 4110 4110 4110 5110 5110B (6) mm 2220 2220 2220 2220 2220 2220 2220 2220 2220H (6) mm 1700 2150 2150 2150 2150 2150 2150 2150 2150Operating weight (6) kg 1460 1700 1900 2050 2310 2370 2520 2800 2940

A

B

H

AB

H

Page 153: Products Guide V01 - ParagonEfficient project management thanks to Climaveneta as unique project leader. Complete and specialized Organization Climaveneta qualifies itself for the

151

Page 154: Products Guide V01 - ParagonEfficient project management thanks to Climaveneta as unique project leader. Complete and specialized Organization Climaveneta qualifies itself for the

152

Main accessoriesSet-up for remote connectivity with ModBus/Echelon/Bacnet protocol cards

Remote keyboard (distance to 200m and to 500m)

Soft starters

Rubber anti-vibration mounting kit

LCD display keyboard type W3000Compact with multi-language user interface (refers to the shown picture)

FeaturesREFRIGERANT GAS R410A

The use of R410A has resulted in units offering better energy efficiency in full respect for the environment (ODP = 0)

SHELL AND TUBES EXCHANGER

The shell and tube exchanger allows to achieve the highest flexibility on the units installation, keeping the efficiency at the maximum level. For this reason, NECS represents the best choice for all the hydronic application on the residential, commercial and industrial markets.

INTEGRATED HYDRONIC MODULE

The built-in hydronic module already contains the main water circuit components; it is available with single or twin in-line, for achieving both low or high head.

MAXIMUM RELIABILITY

Unit with dual-circuit refrigerant section designed to ensure maximum efficiency at full load, ensuring continuity without interruption of operation in the event of temporary stop of one of the 2 circuits.

VersionsB base version

LN low noise version

CommandsW3000 Base / W3000SE CompactThe controller can be chosen as: - W3000 Base: keypad and LED display - W3000SE Compact: the keypad features an easy-to-use interface and a complete LCD display, allowing to consult and intervene on the unit by means of a multi-level menu, with selectable language setting. The diagnostics includes a complete alarm management, with the “black-box” and alarm logging functions for enhanced analysis of the unit operation. Compatibility with the remote keyboard managing up to 10 units. Availability of an internal real time clock for operation scheduling (4-day profiles with 10 hour belts). Common features: The regulation is based on the exclusive QuickMind algorithm, including self-adaptive control logics, beneficial in low water content systems. As alternatives the proportional- or proportional-integral regulations are also available. For multiple units systems, the regulation of the resources, via optional proprietary devices, can be implemented. Energy metering, for both consumption and capacity, can also be developed. Supervision can be easily developed via proprietary devices or the integration in third party systems by means of the most common protocols as ModBus, Bacnet, Bacnet-over-IP, Echelon LonWorks. The defrost adopts a proprietary self-adaptive logic, which features the monitoring of numerous operational parameters. This allows to reduce the number and duration of the defrost cycles, with a benefit for the overall energy efficiency.

Hydronic - reversible

NECS-N 0202T÷0612T

Reversible unit, air source for outdoor installation

50,3 - 169 kWUnit DescriptionOutdoor reversible heat pump for the production of chilled/hot water with hermetic rotary Scroll compressors, axial-flow fans, shell and tubes heat exchanger and thermostatic expansion valve. External panels in Peraluman and structure in aluminium sections. The range is equipped with two compressors on two independent refrigerant circuits.

Page 155: Products Guide V01 - ParagonEfficient project management thanks to Climaveneta as unique project leader. Complete and specialized Organization Climaveneta qualifies itself for the

153

Minimum clearance required0202T-0612T

Switchboard side mm 600Switchboard opposite side mm 600Condensation coil side mm 1000

Note:

1 Evaporator water (in/out) = 12/7°C; Condenser air (in) = 35°C.

2 Condenser water (in/out) = 40/45°C; evaporator air (in) = 7°C - r.h. 87%.

3 Sound power on the basis of measurements made in compliance with ISO 9614 and Eurovent 8/1 for Eurovent certified units; in compliance with ISO 3744 for non-certified units.

4 Average sound pressure level, at 10m distance, unit in a free field on a reflective surface; non-binding value obtained from the sound power level.

5 Unit in standard configuration/execution, without optional accessories

NECS-N / LNModels 0202T 0252T 0302T 0352T 0412T 0452T 0512T 0552T 0612TCOOLING ONLYCooling capacity (1) kW 48 54,6 73,2 83,5 93,9 103 119 132 143Total power input (1) kW 19,1 21,4 27,2 31,9 36 41,6 44,6 53,3 62,7EER 2,52 2,56 2,69 2,62 2,61 2,48 2,67 2,47 2,28ESEER 3,52 3,31 3,46 3,33 3,33 3,17 3,38 3,16 2,93HEATING ONLYHeating capacity (2) kW 54,1 63,6 84,1 96,2 109 121 137 154 170Total power input (2) kW 18,1 20,7 26,1 30,4 34,1 37,9 42,4 48,3 54,3COP 3,00 3,08 3,22 3,16 3,19 3,18 3,24 3,19 3,12COMPRESSORSNo. Compressors/No. Circuits N. 2 / 2 2 / 2 2 / 2 2 / 2 2 / 2 2 / 2 2 / 2 2 / 2 2 / 2NOISE LEVELSSound power (3) dB(A) 80 80 81 83 83 83 84 84 84Sound pressure (4) dB(A) 48 48 49 51 51 51 52 52 52SIZEA (5) mm 2195 2195 2745 2745 2745 2745 3245 3245 3245B (5) mm 1120 1120 1120 1120 1120 1120 1120 1120 1120H (5) mm 1420 1420 1420 1620 1620 1620 1620 1620 1620Operating weight (5) kg * * * * * * * * *

Note:

1 Evaporator water (in/out) = 12/7°C; Condenser air (in) = 35°C.

2 Condenser water (in/out) = 40/45°C; evaporator air (in) = 7°C - r.h. 87%.

3 Sound power on the basis of measurements made in compliance with ISO 9614 and Eurovent 8/1 for Eurovent certified units; in compliance with ISO 3744 for non-certified units.

4 Average sound pressure level, at 10m distance, unit in a free field on a reflective surface; non-binding value obtained from the sound power level.

5 Unit in standard configuration/execution, without optional accessories

NECS-N / BModels 0202T 0252T 0302T 0352T 0412T 0452T 0512T 0552T 0612TCOOLING ONLYCooling capacity (1) kW 50,3 57,5 72 82,5 93,9 107 120 138 151Total power input (1) kW 18,4 20,4 28 32 36 39,8 44 50,4 58,9EER 2,73 2,82 2,57 2,58 2,61 2,68 2,73 2,73 2,56ESEER 3,52 3,59 3,31 3,3 3,31 3,39 3,45 3,46 3,26HEATING ONLYHeating capacity (2) kW 55,1 65,2 81 93,5 105 121 136 157 173Total power input (2) kW 18,6 21,2 26,1 29,8 33,9 37,9 42,3 48,4 54,4COP 2,96 3,08 3,10 3,14 3,11 3,18 3,21 3,23 3,17COMPRESSORSNo. Compressors/No. Circuits N. 2 / 2 2 / 2 2 / 2 2 / 2 2 / 2 2 / 2 2 / 2 2 / 2 2 / 2NOISE LEVELSSound power (3) dB(A) 84 84 85 86 86 86 87 87 87Sound pressure (4) dB(A) 52 52 53 54 54 54 55 55 55SIZEA (5) mm 2195 2195 2195 2195 2745 2745 3245 3245 3245B (5) mm 1120 1120 1120 1120 1120 1120 1120 1120 1120H (5) mm 1420 1420 1420 1420 1420 1420 1620 1620 1620Operating weight (5) kg * * * * * * * * *

COOLINGHEATINGSCROLLAXIALSHELL & TUBES

A

B

H

Page 156: Products Guide V01 - ParagonEfficient project management thanks to Climaveneta as unique project leader. Complete and specialized Organization Climaveneta qualifies itself for the

154

Main accessoriesSoft starters

Set-up for remote connectivity with ModBus, Echelon LonTalk, Bacnet protocol board

Remote keyboard (distance to 200m and to 500m)

LT kit for extending the operating limits in heat pump mode down to -10°C (/SL versions) and -12°C (/CA versions)

FeaturesREFRIGERANT GAS R410A

The use of R410A has resulted in units offering better energy efficiency in full respect for the environment (ODP = 0)

SHELL AND TUBES EXCHANGER

The shell and tube exchanger allows to achieve the highest flexibility on the units installation, keeping the efficiency at the maximum level. For this reason, NECS-N represents the best choice for all the hydronic application on the residential, commercial and industrial markets.ELECTRONIC EXPANSION VALVE SUPPLIED STANDARDThe use of the electronic expansion valve generates considerable benefits, especially in cases of variable demand and different external conditions. It was introduced into these units as a result of accurate design choices concerning the cooling circuit and the optimisation of operation in various different working conditions

CLASS A EFFICIENCY

The full range is also available with the Class A efficiency rating. NECS-N/CA guaranties premium levels of efficiency thanks to the generous sizing of the refrigerant-exchange surface areas and to an accurate control of the fans.

INTEGRATED HYDRONIC MODULE

The incorporated hydronic unit already contains the main water circuit components; it is available in various configurations with one or two pumps with high or low head and the buffer tank

Configurations- base function

D partial condensing heat recovery function

VersionsB base version

SL super-low noise version

CA Class A of efficiency

CommandsW3000SE CompactThe W3000SE Compact controller offers advanced functions and algorithms. The keypad features an easy-to-use interface and a complete LCD display, allowing to consult and intervene on the unit by means of a multi-level menu, with selectable language setting. The regulation is based on the exclusive QuickMind algorithm, including self-adaptive control logics, beneficial in low water content systems. As alternatives the proportional- or proportional-integral regulations are also available. The diagnostics includes a complete alarm management, with the “black-box” and alarm logging functions for enhanced analysis of the unit operation. For multiple units systems, the regulation of the resources, via optional proprietary devices, can be implemented. Energy metering, for both consumption and capacity, can also be developed. Supervision can be easily developed via proprietary devices or the integration in third party systems by means of the most common protocols as ModBus, Bacnet, Bacnet-over-IP, Echelon LonWorks. Compatibility with the remote keyboard managing up to 10 units. Availability of an internal real time clock for operation scheduling (4-day profiles with 10 hour belts). The defrost adopts a proprietary self-adaptive logic, which features the monitoring of numerous operational parameters. This allows to reduce the number and duration of the defrost cycles, with a benefit for the overall energy efficiency.

Hydronic - reversible

NECS-N 1314÷3218

Reversible unit, air source for outdoor installation

339 - 898 kWUnit DescriptionOutdoor heat pump for the production of chilled/hot water with hermetic rotary Scroll compressors, ozone-friendly refrigerant R410A, axial-flow fans, shell and tubes exchanger and electronic expansion valve. The range is composed by units equipped with four, six and eight compressors in multi-circuit configuration.

Page 157: Products Guide V01 - ParagonEfficient project management thanks to Climaveneta as unique project leader. Complete and specialized Organization Climaveneta qualifies itself for the

155

Note:

1 Evaporator water (in/out) = 12/7°C; Condenser air (in) = 35°C.

2 Condenser water (in/out) = 40/45°C; evaporator air (in) = 7°C - r.h. 87%.

3 Sound power on the basis of measurements made in compliance with ISO 9614 and Eurovent 8/1 for Eurovent certified units; in compliance with ISO 3744 for non-certified units.

4 Average sound pressure level, at 10m distance, unit in a free field on a reflective surface; non-binding value obtained from the sound power level.

5 Unit in standard configuration/execution, without optional accessories

NECS-N / SLModels 1314 1414 1614 1716 1816 2016 2116 2416 2418 2618 2818 3018 3218COOLING ONLYCooling capacity (1) kW 320 343 383 413 444 493 516 574 593 638 688 726 765Total power input (1) kW 131 138 154 170 185 199 207 232 247 262 276 293 309EER 2,44 2,49 2,48 2,42 2,40 2,47 2,49 2,48 2,40 2,43 2,49 2,48 2,48ESEER 3,99 4 3,97 4,05 3,99 4,07 4,06 3,95 4 4,05 4,06 4,06 3,96HEATING ONLYHeating capacity (2) kW 368 390 442 474 513 564 586 663 684 736 781 838 884Total power input (2) kW 117 125 139 152 164 180 187 209 219 235 250 264 278COP 3,14 3,12 3,18 3,11 3,12 3,14 3,12 3,17 3,12 3,14 3,13 3,17 3,17COMPRESSORSNo. Compressors/No. Circuits N. 4/2 4/2 4/2 6/3 6/3 6/3 6/3 6/3 8/4 8/4 8/4 8/4 8/4NOISE LEVELSSound power (3) dB(A) 88 88 88 89 89 90 90 91 91 91 92 92 92Sound pressure (4) dB(A) 56 56 56 57 57 57 57 58 58 58 59 59 59SIZEA (5) mm 4515 5080 5080 5690 5690 6865 7430 7430 7430 8605 9780 9780 9780B (5) mm 2260 2260 2260 2260 2260 2260 2260 2260 2260 2260 2260 2260 2260H (5) mm 2450 2450 2450 2450 2450 2450 2450 2450 2450 2450 2450 2450 2450Operating weight (5) kg 3400 3530 3680 4720 4860 5160 5270 5500 6280 6580 6830 6990 7140

Note:

1 Evaporator water (in/out) = 12/7°C; Condenser air (in) = 35°C.

2 Condenser water (in/out) = 40/45°C; evaporator air (in) = 7°C - r.h. 87%.

3 Sound power on the basis of measurements made in compliance with ISO 9614 and Eurovent 8/1 for Eurovent certified units; in compliance with ISO 3744 for non-certified units.

4 Average sound pressure level, at 10m distance, unit in a free field on a reflective surface; non-binding value obtained from the sound power level.

5 Unit in standard configuration/execution, without optional accessories

NECS-N / BModels 1314 1414 1614 1716 1816 2016 2116 2416 2418 2618 2818 3018 3218COOLING ONLYCooling capacity (1) kW 340 364 396 434 478 524 546 594 637 678 728 761 792Total power input (1) kW 114 120 139 150 160 173 180 209 213 229 240 259 279EER 2,60 2,76 2,62 2,64 2,69 2,74 2,76 2,62 2,69 2,68 2,76 2,69 2,62ESEER 3,80 3,88 3,79 3,88 3,78 3,89 3,91 3,77 3,78 3,83 3,92 3,88 3,78HEATING ONLYHeating capacity (2) kW 371 398 436 474 515 572 597 654 686 742 796 834 871Total power input (2) kW 110 118 131 142 153 169 176 196 203 221 235 248 262COP 3,03 3,07 3,05 3,04 3,02 3,06 3,08 3,05 3,02 3,03 3,08 3,07 3,05COMPRESSORSNo. Compressors/No. Circuits N. 4/2 4/2 4/2 6/3 6/3 6/3 6/3 6/3 8/4 8/4 8/4 8/4 8/4NOISE LEVELSSound power (3) dB(A) 96 96 96 96 97 97 97 98 98 98 99 99 99Sound pressure (4) dB(A) 64 64 64 64 65 65 65 66 65 65 66 66 66SIZEA (5) mm 3905 3905 3905 4515 5690 5690 5690 5690 7430 7430 7430 7430 7430B (5) mm 2260 2260 2260 2260 2260 2260 2260 2260 2260 2260 2260 2260 2260H (5) mm 2450 2450 2450 2450 2450 2450 2450 2450 2450 2450 2450 2450 2450Operating weight (5) kg 3170 3250 3280 4220 4610 4740 4810 4860 5950 6080 6230 6260 6300

COOLINGHEATINGSCROLLAXIALSHELL & TUBESENERGY CLASS

Page 158: Products Guide V01 - ParagonEfficient project management thanks to Climaveneta as unique project leader. Complete and specialized Organization Climaveneta qualifies itself for the

156

Minimum clearance required1314-3218

Switchboard side mm 1500Switchboard opposite side mm 1500Plant exchagers opposite side mm 1500Plant exchagers side mm 2000

Note:

1 Evaporator water (in/out) = 12/7°C; Condenser air (in) = 35°C.

2 Condenser water (in/out) = 40/45°C; evaporator air (in) = 7°C - r.h. 87%.

3 Sound power on the basis of measurements made in compliance with ISO 9614 and Eurovent 8/1 for Eurovent certified units; in compliance with ISO 3744 for non-certified units.

4 Average sound pressure level, at 10m distance, unit in a free field on a reflective surface; non-binding value obtained from the sound power level.

5 Unit in standard configuration/execution, without optional accessories

NECS-N / CAModels 1314 1414 1614 1716 1816 2016 2116 2416 2418 2618 2818 3018 3218COOLING ONLYCooling capacity (1) kW 352 372 417 453 504 538 559 625 667 710 745 789 833Total power input (1) kW 121 128 143 155 173 185 192 215 228 242 256 270 287EER 2,90 2,91 2,91 2,91 2,92 2,91 2,92 2,91 2,92 2,93 2,92 2,92 2,91ESEER 4,12 4,20 4,07 4,19 4,08 4,18 4,17 4,09 4,09 4,14 4,18 4,17 4,09HEATING ONLYHeating capacity (2) kW 383 409 449 497 533 586 614 674 708 766 819 860 898Total power input (2) kW 119 128 140 155 166 183 191 210 221 239 255 269 280COP 3,21 3,20 3,21 3,21 3,21 3,21 3,21 3,21 3,20 3,20 3,21 3,20 3,21COMPRESSORSNo. Compressors/No. Circuits N. 4/2 4/2 4/2 6/3 6/3 6/3 6/3 6/3 8/4 8/4 8/4 8/4 8/4NOISE LEVELSSound power (3) dB(A) 97 97 97 97 98 98 98 99 99 99 100 100 100Sound pressure (4) dB(A) 65 65 65 65 66 66 66 67 66 66 67 67 67SIZEA (5) mm 5080 5080 5080 6255 7430 7430 7430 7430 9780 9780 9780 9780 9780B (5) mm 2260 2260 2260 2260 2260 2260 2260 2260 2260 2260 2260 2260 2260H (5) mm 2450 2450 2450 2450 2450 2450 2450 2450 2450 2450 2450 2450 2450Operating weight (5) kg 3490 3580 3610 4840 5120 5270 5350 5400 6610 6760 6940 6970 7000

AB

H

Page 159: Products Guide V01 - ParagonEfficient project management thanks to Climaveneta as unique project leader. Complete and specialized Organization Climaveneta qualifies itself for the

157

Page 160: Products Guide V01 - ParagonEfficient project management thanks to Climaveneta as unique project leader. Complete and specialized Organization Climaveneta qualifies itself for the

158

Main accessoriesSet-up for remote connectivity with ModBus/Echelon/Bacnet protocol cards

Remote keyboard (distance to 200m and to 500m)

Soft starters

LT kit for working down to -10°C in heat pump mode

Rubber anti-vibration mounting kit. Spring anti-vibration mounting kit

FeaturesREFRIGERANT GAS R410A

The use of R410A has resulted in units offering better energy efficiency in full respect for the environment (ODP = 0)

TOTAL VERSATILITY

Climaveneta is the only company offering units with Scroll compressors in 5 versions and 2 different configurations designed to satisfy all service system and application requirements

SHELL AND TUBES EXCHANGER

The shell and tube exchanger allows to achieve the highest flexibility on the units installation, keeping the efficiency at the maximum level. For this reason, NECS-N represents the best choice for all the hydronic application on the residential, commercial and industrial markets.

INTEGRATED HYDRONIC MODULE

The built-in hydronic module already contains the main water circuit components; it is available with single or twin in-line, for achieving both low or high head.

Configurations- base function

D partial condensing heat recovery function

VersionsB base version

HL low noise, high efficiency, high outdoor temperature version

HT high efficiency, high outdoor temperature version

LN low noise version

SL super-low noise version

CommandsW3000SE CompactThe W3000SE Compact controller offers advanced functions and algorithms. The keypad features an easy-to-use interface and a complete LCD display, allowing to consult and intervene on the unit by means of a multi-level menu, with selectable language setting. The regulation is based on the exclusive QuickMind algorithm, including self-adaptive control logics, beneficial in low water content systems. As alternatives the proportional- or proportional-integral regulations are also available. The diagnostics includes a complete alarm management, with the “black-box” and alarm logging functions for enhanced analysis of the unit operation. For multiple units systems, the regulation of the resources, via optional proprietary devices, can be implemented. Energy metering, for both consumption and capacity, can also be developed. Supervision can be easily developed via proprietary devices or the integration in third party systems by means of the most common protocols as ModBus, Bacnet, Bacnet-over-IP, Echelon LonWorks. Compatibility with the remote keyboard managing up to 10 units. Availability of an internal real time clock for operation scheduling (4-day profiles with 10 hour belts). The defrost adopts a proprietary self-adaptive logic, which features the monitoring of numerous operational parameters. This allows to reduce the number and duration of the defrost cycles, with a benefit for the overall energy efficiency.

Hydronic - reversible

NECS-ST-N 0504÷1204

Reversible unit, air source for outdoor installation

103 - 322 kWUnit DescriptionOutdoor reversible heat pump for the production of chilled/hot water with hermetic rotary Scroll compressors, axial-flow fans, shell and tubes exchanger and thermostatic expansion valve. External panels in Peraluman and structure in aluminium sections. The range is equipped with four compressors on two circuits.

Page 161: Products Guide V01 - ParagonEfficient project management thanks to Climaveneta as unique project leader. Complete and specialized Organization Climaveneta qualifies itself for the

159

Note:

1 Evaporator water (in/out) = 12/7°C; Condenser air (in) = 35°C.

2 Condenser water (in/out) = 40/45°C; evaporator air (in) = 7°C - r.h. 87%.

3 Evaporator water (in/out) = 12/7°C; Condenser air (in) = 35°C. Desuperheater water (in/out) = 40/45°C.

4 Sound power on the basis of measurements made in compliance with ISO 9614 and Eurovent 8/1 for Eurovent certified units; in compliance with ISO 3744 for non-certified units.

5 Average sound pressure level, at 10m distance, unit in a free field on a reflective surface; non-binding value obtained from the sound power level.

6 Unit in standard configuration/execution, without optional accessories

NECS-ST-N / HLModels 0504 0524 0604 0704 0804 0904 1004 1104 1204COOLING ONLYCooling capacity (1) kW 113 129 142 163 190 209 236 273 307Total power input (1) kW 43,8 51 58,9 67,4 73,9 84,6 92,6 103 119EER 2,58 2,53 2,41 2,42 2,57 2,47 2,55 2,63 2,57ESEER 3,75 3,81 3,78 3,91 3,79 3,81 3,92 4,11 3,91HEATING ONLYHeating capacity (2) kW 128 144 159 181 211 233 261 303 340Total power input (2) kW 44,3 49,2 53,9 60,9 71 78,7 86,4 98,7 112COP 2,89 2,93 2,95 2,97 2,97 2,96 3,02 3,07 3,01COOLING WITH PARTIAL RECOVERYCooling capacity (3) kW 117 133 148 169 197 217 245 283 318Total power input (3) kW 42,3 49,1 57,1 64,9 71,6 82,2 89,4 101 116Desuperheater heating capacity (3) kW 34,7 41 48,3 55,6 59,6 69,4 76 86,4 98,1COMPRESSORSNo. Compressors/No. Circuits N. 4/2 4/2 4/2 4/2 4/2 4/2 4/2 4/2 4/2NOISE LEVELSSound power (4) dB(A) 86 86 86 86 88 88 88 90 91Sound pressure (5) dB(A) 54 54 54 54 56 56 56 58 59SIZEA (6) mm 3110 3110 3110 3110 4110 4110 4110 5110 5110B (6) mm 2220 2220 2220 2220 2220 2220 2220 2220 2220H (6) mm 1700 2150 2150 2150 2150 2150 2150 2150 2150Operating weight (6) kg 1460 1700 1840 1980 2310 2370 2520 2800 2940

Note:

1 Evaporator water (in/out) = 12/7°C; Condenser air (in) = 35°C.

2 Condenser water (in/out) = 40/45°C; evaporator air (in) = 7°C - r.h. 87%.

3 Evaporator water (in/out) = 12/7°C; Condenser air (in) = 35°C. Desuperheater water (in/out) = 40/45°C.

4 Sound power on the basis of measurements made in compliance with ISO 9614 and Eurovent 8/1 for Eurovent certified units; in compliance with ISO 3744 for non-certified units.

5 Average sound pressure level, at 10m distance, unit in a free field on a reflective surface; non-binding value obtained from the sound power level.

6 Unit in standard configuration/execution, without optional accessories

NECS-ST-N / BModels 0504 0524 0604 0704 0804 0904 1004 1104 1204COOLING ONLYCooling capacity (1) kW 111 129 147 166 189 211 240 277 311Total power input (1) kW 43,7 54 60 68,9 75,9 85,1 95,6 107 120EER 2,54 2,39 2,45 2,41 2,49 2,48 2,51 2,58 2,58ESEER 3,99 3,39 3,57 3,64 3,80 3,88 3,68 3,84 3,93HEATING ONLYHeating capacity (2) kW 127 145 167 185 209 234 267 306 344Total power input (2) kW 43,6 52,7 58 64,7 72,1 79,9 92,1 104 116COP 2,91 2,75 2,88 2,86 2,90 2,93 2,90 2,94 2,96COOLING WITH PARTIAL RECOVERYCooling capacity (3) kW 116 134 152 172 196 219 249 287 322Total power input (3) kW 42,5 52,4 58,1 66,8 73,4 82,5 92,7 104 117Desuperheater heating capacity (3) kW 35,4 40,7 46 54 60,1 68,6 74,1 84,6 96,3COMPRESSORSNo. Compressors/No. Circuits N. 4/2 4/2 4/2 4/2 4/2 4/2 4/2 4/2 4/2NOISE LEVELSSound power (4) dB(A) 91 92 92 92 92 93 94 95 95Sound pressure (5) dB(A) 59 60 60 60 60 61 62 63 63SIZEA (6) mm 3110 3110 3110 3110 3110 4110 4110 4110 4110B (6) mm 2220 2220 2220 2220 2220 2220 2220 2220 2220H (6) mm 1700 1700 1700 2150 2150 2150 2150 2150 2150Operating weight (6) kg 1380 1570 1750 1900 2080 2270 2410 2540 2700

COOLINGHEATING

r HFCR-410A

SCROLLAXIALSHELL & TUBES

Page 162: Products Guide V01 - ParagonEfficient project management thanks to Climaveneta as unique project leader. Complete and specialized Organization Climaveneta qualifies itself for the

160

Note:

1 Evaporator water (in/out) = 12/7°C; Condenser air (in) = 35°C.

2 Condenser water (in/out) = 40/45°C; evaporator air (in) = 7°C - r.h. 87%.

3 Evaporator water (in/out) = 12/7°C; Condenser air (in) = 35°C. Desuperheater water (in/out) = 40/45°C.

4 Sound power on the basis of measurements made in compliance with ISO 9614 and Eurovent 8/1 for Eurovent certified units; in compliance with ISO 3744 for non-certified units.

5 Average sound pressure level, at 10m distance, unit in a free field on a reflective surface; non-binding value obtained from the sound power level.

6 Unit in standard configuration/execution, without optional accessories

NECS-ST-N / LNModels 0504 0524 0604 0704 0804 0904 1004 1104 1204COOLING ONLYCooling capacity (1) kW 103 123 141 156 177 199 227 261 291Total power input (1) kW 46,2 53,5 60 70,3 78,3 87,7 96,2 110 125EER 2,23 2,30 2,35 2,22 2,26 2,27 2,36 2,37 2,32ESEER 3,89 3,66 3,74 3,78 3,77 3,89 3,76 3,92 3,86HEATING ONLYHeating capacity (2) kW 122 138 158 176 198 225 254 290 324Total power input (2) kW 41,5 48,9 53,7 60,7 67,8 75,5 86,1 98 110COP 2,94 2,82 2,94 2,90 2,92 2,98 2,95 2,96 2,94COOLING WITH PARTIAL RECOVERYCooling capacity (3) kW 107 128 146 162 184 207 236 270 302Total power input (3) kW 44,7 51,8 58 68,2 75,9 84,9 93,4 107 121Desuperheater heating capacity (3) kW 39,2 43,5 49,2 58,7 65,7 74,1 79,7 92 105COMPRESSORSNo. Compressors/No. Circuits N. 4/2 4/2 4/2 4/2 4/2 4/2 4/2 4/2 4/2NOISE LEVELSSound power (4) dB(A) 85 86 86 86 86 87 88 89 89Sound pressure (5) dB(A) 53 54 54 54 54 55 56 57 57SIZEA (6) mm 3110 3110 3110 3110 3110 4110 4110 4110 4110B (6) mm 2220 2220 2220 2220 2220 2220 2220 2220 2220H (6) mm 1700 1700 1700 2150 2150 2150 2150 2150 2150Operating weight (6) kg 1380 1570 1750 1900 2080 2270 2410 2540 2700

Note:

1 Evaporator water (in/out) = 12/7°C; Condenser air (in) = 35°C.

2 Condenser water (in/out) = 40/45°C; evaporator air (in) = 7°C - r.h. 87%.

3 Evaporator water (in/out) = 12/7°C; Condenser air (in) = 35°C. Desuperheater water (in/out) = 40/45°C.

4 Sound power on the basis of measurements made in compliance with ISO 9614 and Eurovent 8/1 for Eurovent certified units; in compliance with ISO 3744 for non-certified units.

5 Average sound pressure level, at 10m distance, unit in a free field on a reflective surface; non-binding value obtained from the sound power level.

6 Unit in standard configuration/execution, without optional accessories

NECS-ST-N / HTModels 0504 0524 0604 0704 0804 0904 1004 1104 1204COOLING ONLYCooling capacity (1) kW 117 134 149 172 198 219 248 287 322Total power input (1) kW 45,5 51,3 58,4 65,7 75,3 84,9 91,5 102 118EER 2,57 2,61 2,55 2,62 2,63 2,58 2,71 2,79 2,71ESEER 3,42 3,53 3,64 3,77 3,57 3,60 3,82 3,98 3,80HEATING ONLYHeating capacity (2) kW 134 150 167 191 220 244 274 315 357Total power input (2) kW 48,2 53 58 65,2 76,9 84,7 92,3 104 121COP 2,78 2,83 2,88 2,93 2,86 2,88 2,97 3,02 2,95COOLING WITH PARTIAL RECOVERYCooling capacity (3) kW 121 139 155 178 205 228 257 297 334Total power input (3) kW 44,1 49,8 56,8 63,7 73,1 82,7 88,9 99,6 115Desuperheater heating capacity (3) kW 33 38,3 44,8 51,1 56 64,8 70,6 80,5 91,2COMPRESSORSNo. Compressors/No. Circuits N. 4/2 4/2 4/2 4/2 4/2 4/2 4/2 4/2 4/2NOISE LEVELSSound power (4) dB(A) 92 92 92 92 94 94 94 97 97Sound pressure (5) dB(A) 60 60 60 60 62 62 62 64 65SIZEA (6) mm 3110 3110 3110 3110 4110 4110 4110 5110 5110B (6) mm 2220 2220 2220 2220 2220 2220 2220 2220 2220H (6) mm 1700 2150 2150 2150 2150 2150 2150 2150 2150Operating weight (6) kg 1460 1700 1840 1980 2310 2370 2520 2800 2940

Page 163: Products Guide V01 - ParagonEfficient project management thanks to Climaveneta as unique project leader. Complete and specialized Organization Climaveneta qualifies itself for the

161

Minimum clearance required0504-1204

Switchboard side mm 1100Switchboard opposite side mm 1100Condensation coil side mm 2000

Note:

1 Evaporator water (in/out) = 12/7°C; Condenser air (in) = 35°C.

2 Condenser water (in/out) = 40/45°C; evaporator air (in) = 7°C - r.h. 87%.

3 Evaporator water (in/out) = 12/7°C; Condenser air (in) = 35°C. Desuperheater water (in/out) = 40/45°C.

4 Sound power on the basis of measurements made in compliance with ISO 9614 and Eurovent 8/1 for Eurovent certified units; in compliance with ISO 3744 for non-certified units.

5 Average sound pressure level, at 10m distance, unit in a free field on a reflective surface; non-binding value obtained from the sound power level.

6 Unit in standard configuration/execution, without optional accessories

NECS-ST-N / SLModels 0504 0524 0604 0704 0804 0904 1004 1104 1204COOLING ONLYCooling capacity (1) kW 108 124 141 159 183 201 225 261 294Total power input (1) kW 45 52,1 58,3 67,7 75,3 87,4 95,3 108 123EER 2,40 2,38 2,42 2,35 2,43 2,30 2,36 2,41 2,38ESEER 3,84 3,93 3,98 4,05 3,87 3,88 3,93 4,13 3,93HEATING ONLYHeating capacity (2) kW 125 140 158 178 205 226 253 295 330Total power input (2) kW 42,8 47,5 52,2 59,5 68,6 76,1 83,8 96,1 110COP 2,92 2,95 3,03 2,99 2,99 2,97 3,02 3,07 3COOLING WITH PARTIAL RECOVERYCooling capacity (3) kW 112 128 146 165 190 208 234 271 305Total power input (3) kW 43,5 50,3 56,3 65,4 73 84,4 92,3 105 119Desuperheater heating capacity (3) kW 37 43,3 48,9 57,3 62,7 73,3 80,6 92 104COMPRESSORSNo. Compressors/No. Circuits N. 4/2 4/2 4/2 4/2 4/2 4/2 4/2 4/2 4/2NOISE LEVELSSound power (4) dB(A) 82 82 82 82 83 83 83 85 86Sound pressure (5) dB(A) 50 50 50 50 51 51 51 53 54SIZEA (6) mm 3110 3110 3110 3110 4110 4110 4110 5110 5110B (6) mm 2220 2220 2220 2220 2220 2220 2220 2220 2220H (6) mm 1700 2150 2150 2150 2150 2150 2150 2150 2150Operating weight (6) kg 1460 1700 1900 2050 2310 2370 2520 2800 2940

AB

H

Page 164: Products Guide V01 - ParagonEfficient project management thanks to Climaveneta as unique project leader. Complete and specialized Organization Climaveneta qualifies itself for the

162

Main accessoriesCompressor power factor device

Electronic expansion valve

Variable speed condensation control (standard on /LN, /SL)

Remote keyboard (distance to 200m and to 500m)

Set-up for remote connectivity with ModBus, Echelon LonTalk, Bacnet protocol board

FeaturesFLEXIBILITY

Flexibility in applications thanks to the many available functions and versions

EXTENSIVE RANGE OF OPERATION

Extensive range of operation with external air temperature up to 46°C in summer and down to -10°C in winter with LT version

HOT WATER SUPPLY

Supply of hot water in use up to 55°C, offering maximum versatility with respect to different plant engineering solutions

STANDARD WATER PUMP

Standard water pump with pump unit options and possible storage tank: 1 or 2 pumps, 2 or 4-pole motor, for high or low head

VersionsB base version

LN low noise version

LT low outdoor temperature version

SL super-low noise version

CommandsW3000SE LargeThe W3000SE Large controller offers advanced functions and algorithms. The keypad features an easy-to-use interface and a complete LCD display, allowing to consult and intervene on the unit by means of a multi-level menu, with selectable language setting. The regulation features the continuous modulation of capacity, based on a dynamic dead band and referring to the leaving water temperature. As alternative, step-wise regulation is also available, referred to the return water temperature with selectable proportional- or proportional-integral logic. The diagnostics includes a complete alarm management, with the “black-box” and alarm logging functions for enhanced analysis of the unit operation. For multiple units systems, the regulation of the resources, via optional proprietary devices, can be implemented. Energy metering, for both consumption and capacity, can also be developed. Supervision can be easily developed via proprietary devices or the integration in third party systems by means of the most common protocols as ModBus, Bacnet, Bacnet-over-IP, Echelon LonWorks. Compatibility with the remote keyboard managing up to 10 units. Availability of an internal real time clock for operation scheduling (4-day profiles with 10 hour belts). The defrost adopts a proprietary self-adaptive logic, which features the monitoring of numerous operational parameters. This allows to reduce the number and duration of the defrost cycles, with a benefit for the overall energy efficiency.

Hydronic - reversible

RECS 1052÷1952

Reversible unit, air source for outdoor installation

195 - 385 kWUnit DescriptionOutdoor unit in heat pump mode for the production of chilled/hot water with semi-hermetic screw compressors optimized for R134a, axial-flow fans, condensing coil with copper tubes and aluminium fins, plate heat exchanger and thermostatic expansion valve. Frame with base in polyester-painted thick hot-galvanised sheet steel and external panels in peraluman. Flexible and reliable unit; it easily adapts itself to different thermal load conditions thanks to the precise thermoregulation.

Page 165: Products Guide V01 - ParagonEfficient project management thanks to Climaveneta as unique project leader. Complete and specialized Organization Climaveneta qualifies itself for the

163

Note:

1 Evaporator water (in/out) = 12/7°C; Condenser air (in) = 35°C.

2 Condenser water (in/out) = 40/45°C; evaporator air (in) = 7°C - r.h. 87%.

3 Sound power on the basis of measurements made in compliance with ISO 9614 and Eurovent 8/1 for Eurovent certified units; in compliance with ISO 3744 for non-certified units.

4 Average sound pressure level, at 10m distance, unit in a free field on a reflective surface; non-binding value obtained from the sound power level.

5 Unit in standard configuration/execution, without optional accessories

RECS / LNModels 1052 1152 1352 1552 1752 1952COOLING ONLYCooling capacity (1) kW 189 229 266 298 346 371Total power input (1) kW 74,7 96,2 112 115 141 158EER 2,53 2,38 2,37 2,59 2,45 2,34ESEER 3,61 3,26 3,37 3,68 3,46 3,48HEATING ONLYHeating capacity (2) kW 205 247 289 322 374 401Total power input (2) kW 65,9 83,2 96 101 123 132COP 3,11 2,97 3,01 3,17 3,04 3,03COMPRESSORSNo. Compressors/No. Circuits N. 2/2 2/2 2/2 2/2 2/2 2/2NOISE LEVELSSound power (3) dB(A) 90 91 91 92 92 92Sound pressure (4) dB(A) 58 59 59 60 60 60SIZEA (5) mm 4610 4610 4610 5610 5610 5610B (5) mm 2220 2220 2220 2220 2220 2220H (5) mm 2150 2150 2420 2430 2430 2430Operating weight (5) kg 2910 3450 3590 3860 4100 4170

Note:

1 Evaporator water (in/out) = 12/7°C; Condenser air (in) = 35°C.

2 Condenser water (in/out) = 40/45°C; evaporator air (in) = 7°C - r.h. 87%.

3 Sound power on the basis of measurements made in compliance with ISO 9614 and Eurovent 8/1 for Eurovent certified units; in compliance with ISO 3744 for non-certified units.

4 Average sound pressure level, at 10m distance, unit in a free field on a reflective surface; non-binding value obtained from the sound power level.

5 Unit in standard configuration/execution, without optional accessories

RECS / BModels 1052 1152 1352 1552 1752 1952COOLING ONLYCooling capacity (1) kW 195 238 276 307 359 385Total power input (1) kW 73,9 95,6 109 113 138 154EER 2,64 2,49 2,53 2,70 2,59 2,49ESEER 3,43 3,13 3,25 3,49 3,31 3,34HEATING ONLYHeating capacity (2) kW 212 259 301 332 389 418Total power input (2) kW 70 89,6 102 107 130 140COP 3,03 2,89 2,94 3,08 2,97 2,97COMPRESSORSNo. Compressors/No. Circuits N. 2/2 2/2 2/2 2/2 2/2 2/2NOISE LEVELSSound power (3) dB(A) 96 97 97 98 98 98Sound pressure (4) dB(A) 64 65 65 66 66 66SIZEA (5) mm 4610 4610 4610 5610 5610 5610B (5) mm 2220 2220 2220 2220 2220 2220H (5) mm 2150 2150 2420 2430 2430 2430Operating weight (5) kg 2910 3450 3590 3860 4100 4170

COOLINGHEATING

r HFCR-134a

SCREWAXIALPLATES

Page 166: Products Guide V01 - ParagonEfficient project management thanks to Climaveneta as unique project leader. Complete and specialized Organization Climaveneta qualifies itself for the

164

Minimum clearance required1052-1952

Switchboard side mm 1100Switchboard opposite side mm 1100Condensation coil side mm 2000

Note:

1 Evaporator water (in/out) = 12/7°C; Condenser air (in) = 35°C.

2 Condenser water (in/out) = 40/45°C; evaporator air (in) = 7°C - r.h. 87%.

3 Sound power on the basis of measurements made in compliance with ISO 9614 and Eurovent 8/1 for Eurovent certified units; in compliance with ISO 3744 for non-certified units.

4 Average sound pressure level, at 10m distance, unit in a free field on a reflective surface; non-binding value obtained from the sound power level.

5 Unit in standard configuration/execution, without optional accessories

RECS / SLModels 1052 1152 1352 1552 1752 1952COOLING ONLYCooling capacity (1) kW 190 228 266 298 333 378Total power input (1) kW 74,5 95,4 110 115 148 152EER 2,55 2,39 2,40 2,57 2,24 2,48ESEER 3,59 3,38 3,50 3,69 3,38 3,63HEATING ONLYHeating capacity (2) kW 206 249 294 322 363 412Total power input (2) kW 66,5 81,9 94,8 101 119 132COP 3,10 3,04 3,10 3,17 3,03 3,11COMPRESSORSNo. Compressors/No. Circuits N. 2/2 2/2 2/2 2/2 2/2 2/2NOISE LEVELSSound power (3) dB(A) 86 87 87 88 88 88Sound pressure (4) dB(A) 54 55 55 56 56 55SIZEA (5) mm 4610 4610 5610 5610 5610 6610B (5) mm 2220 2220 2220 2220 2220 2220H (5) mm 2150 2420 2430 2430 2430 2430Operating weight (5) kg 3010 3550 3830 3960 4100 4720

A

B

H

Note:

1 Evaporator water (in/out) = 12/7°C; Condenser air (in) = 35°C.

2 Condenser water (in/out) = 40/45°C; evaporator air (in) = 7°C - r.h. 87%.

3 Sound power on the basis of measurements made in compliance with ISO 9614 and Eurovent 8/1 for Eurovent certified units; in compliance with ISO 3744 for non-certified units.

4 Average sound pressure level, at 10m distance, unit in a free field on a reflective surface; non-binding value obtained from the sound power level.

5 Unit in standard configuration/execution, without optional accessories

RECS / LTModels 1052 1152 1352 1552 1752 1952COOLING ONLYCooling capacity (1) kW 200 248 289 313 372 399Total power input (1) kW 74,7 88,6 103 113 133 147EER 2,69 2,80 2,78 2,77 2,79 2,70ESEER 3,19 3,38 3,25 3,36 3,32 3,34HEATING ONLYHeating capacity (2) kW 220 272 318 342 406 438Total power input (2) kW 74,6 90,7 107 112 136 146COP 2,95 3,00 2,96 3,04 2,98 2,99COMPRESSORSNo. Compressors/No. Circuits N. 2/2 2/2 2/2 2/2 2/2 2/2NOISE LEVELSSound power (3) dB(A) 97 97 97 98 99 99Sound pressure (4) dB(A) 65 65 65 66 66 66SIZEA (5) mm 4610 5610 5610 5610 6610 6610B (5) mm 2220 2220 2220 2220 2220 2220H (5) mm 2150 2430 2430 2430 2430 2430Operating weight (5) kg 3010 3790 3930 3960 4650 4720

Page 167: Products Guide V01 - ParagonEfficient project management thanks to Climaveneta as unique project leader. Complete and specialized Organization Climaveneta qualifies itself for the

165

Page 168: Products Guide V01 - ParagonEfficient project management thanks to Climaveneta as unique project leader. Complete and specialized Organization Climaveneta qualifies itself for the

166

Main accessoriesRemote keyboard (distance to 200m and to 500m)

Compressor power factor device

Electronic expansion valve

Variable speed condensation control (standard on /LN, /SL)Set-up for remote connectivity with ModBus, Echelon LonTalk, Bacnet protocol board

FeaturesFLEXIBILITY

Flexibility in applications thanks to the many available functions and versions

EXTENSIVE RANGE OF OPERATION

Extensive range of operation with external air temperature up to 46°C in summer and down to -10°C in winter with LT version

HOT WATER SUPPLY

Supply of hot water in use up to 55°C, offering maximum versatility with respect to different plant engineering solutions

Configurations- base function

D partial condensing heat recovery function

VersionsB base version

LN low noise version

LT low outdoor temperature version

SL super-low noise version

CommandsW3000SE LargeThe W3000SE Large controller offers advanced functions and algorithms. The keypad features an easy-to-use interface and a complete LCD display, allowing to consult and intervene on the unit by means of a multi-level menu, with selectable language setting. The regulation features the continuous modulation of capacity, based on a dynamic dead band and referring to the leaving water temperature. As alternative, step-wise regulation is also available, referred to the return water temperature with selectable proportional- or proportional-integral logic. The diagnostics includes a complete alarm management, with the “black-box” and alarm logging functions for enhanced analysis of the unit operation. For multiple units systems, the regulation of the resources, via optional proprietary devices, can be implemented. Energy metering, for both consumption and capacity, can also be developed. Supervision can be easily developed via proprietary devices or the integration in third party systems by means of the most common protocols as ModBus, Bacnet, Bacnet-over-IP, Echelon LonWorks. Compatibility with the remote keyboard managing up to 10 units. Availability of an internal real time clock for operation scheduling (4-day profiles with 10 hour belts). The defrost adopts a proprietary self-adaptive logic, which features the monitoring of numerous operational parameters. This allows to reduce the number and duration of the defrost cycles, with a benefit for the overall energy efficiency.

Hydronic - reversible

RECS 1062÷1962

Reversible unit, air source for outdoor installation

195 - 385 kWUnit DescriptionOutdoor heat pump unit for the production of chilled/hot water with semi-hermetic screw compressors optimized for R134a, axial-flow fans, external coil with copper tubes and aluminium fines, shell and tubes heat exchangers designed by Climaveneta and thermostatic expansion valve. Base and supporting structure and panels are galvanized epoxy powder coated steel with increased thickness. These units are designed for two-pipes systems and are able to produce hot or cold water according to the selected operation mode; the precise thermoregulation guarantees an optimal response to load´s changes, in every operating conditions.

Page 169: Products Guide V01 - ParagonEfficient project management thanks to Climaveneta as unique project leader. Complete and specialized Organization Climaveneta qualifies itself for the

167

Note:

1 Evaporator water (in/out) = 12/7°C; Condenser air (in) = 35°C.

2 Condenser water (in/out) = 40/45°C; evaporator air (in) = 7°C - r.h. 87%.

3 Sound power on the basis of measurements made in compliance with ISO 9614 and Eurovent 8/1 for Eurovent certified units; in compliance with ISO 3744 for non-certified units.

4 Average sound pressure level, at 10m distance, unit in a free field on a reflective surface; non-binding value obtained from the sound power level.

5 Unit in standard configuration/execution, without optional accessories

RECS / LNModels 1062 1162 1362 1562 1762 1962COOLING ONLYCooling capacity (1) kW 189 229 266 298 346 371Total power input (1) kW 74,8 96,3 112 115 141 158EER 2,53 2,38 2,37 2,59 2,45 2,34ESEER 3,61 3,26 3,37 3,68 3,46 3,48HEATING ONLYHeating capacity (2) kW 205 247 289 322 374 401Total power input (2) kW 65,9 83,4 96,1 102 123 132COP 3,11 2,97 3,01 3,17 3,04 3,03COMPRESSORSNo. Compressors/No. Circuits N. 2/2 2/2 2/2 2/2 2/2 2/2NOISE LEVELSSound power (3) dB(A) 90 91 91 92 92 92Sound pressure (4) dB(A) 58 59 59 60 60 60SIZEA (5) mm 4610 4610 4610 5610 5610 5610B (5) mm 2220 2220 2220 2220 2220 2220H (5) mm 2150 2150 2420 2430 2430 2430Operating weight (5) kg 2960 3470 3860 4140 4340 4640

Note:

1 Evaporator water (in/out) = 12/7°C; Condenser air (in) = 35°C.

2 Condenser water (in/out) = 40/45°C; evaporator air (in) = 7°C - r.h. 87%.

3 Sound power on the basis of measurements made in compliance with ISO 9614 and Eurovent 8/1 for Eurovent certified units; in compliance with ISO 3744 for non-certified units.

4 Average sound pressure level, at 10m distance, unit in a free field on a reflective surface; non-binding value obtained from the sound power level.

5 Unit in standard configuration/execution, without optional accessories

RECS / BModels 1062 1162 1362 1562 1762 1962COOLING ONLYCooling capacity (1) kW 195 238 276 307 359 385Total power input (1) kW 73,9 95,6 109 113 138 154EER 2,64 2,49 2,53 2,70 2,59 2,49ESEER 3,43 3,13 3,25 3,49 3,31 3,34HEATING ONLYHeating capacity (2) kW 212 259 301 332 389 418Total power input (2) kW 70 89,6 102 107 130 140COP 3,03 2,89 2,94 3,08 2,97 2,97COMPRESSORSNo. Compressors/No. Circuits N. 2/2 2/2 2/2 2/2 2/2 2/2NOISE LEVELSSound power (3) dB(A) 96 97 97 98 98 98Sound pressure (4) dB(A) 64 65 65 66 66 66SIZEA (5) mm 4610 4610 4610 5610 5610 5610B (5) mm 2220 2220 2220 2220 2220 2220H (5) mm 2150 2150 2420 2430 2430 2430Operating weight (5) kg 2960 3470 3860 4140 4340 4640

COOLINGHEATING

r HFCR-134a

SCREWAXIALSHELL & TUBES

Page 170: Products Guide V01 - ParagonEfficient project management thanks to Climaveneta as unique project leader. Complete and specialized Organization Climaveneta qualifies itself for the

168

Minimum clearance required1062-1962

Switchboard side mm 1100Switchboard opposite side mm 1100Condensation coil side mm 2000

Note:

1 Evaporator water (in/out) = 12/7°C; Condenser air (in) = 35°C.

2 Condenser water (in/out) = 40/45°C; evaporator air (in) = 7°C - r.h. 87%.

3 Sound power on the basis of measurements made in compliance with ISO 9614 and Eurovent 8/1 for Eurovent certified units; in compliance with ISO 3744 for non-certified units.

4 Average sound pressure level, at 10m distance, unit in a free field on a reflective surface; non-binding value obtained from the sound power level.

5 Unit in standard configuration/execution, without optional accessories

RECS / SLModels 1062 1162 1362 1562 1762 1962COOLING ONLYCooling capacity (1) kW 190 228 266 298 333 378Total power input (1) kW 74,4 95,2 111 116 149 152EER 2,55 2,39 2,40 2,57 2,23 2,49ESEER 3,59 3,38 3,50 3,69 3,38 3,63HEATING ONLYHeating capacity (2) kW 206 249 294 322 363 412Total power input (2) kW 66,5 81,7 94,7 102 120 133COP 3,10 3,05 3,10 3,16 3,02 3,10COMPRESSORSNo. Compressors/No. Circuits N. 2/2 2/2 2/2 2/2 2/2 2/2NOISE LEVELSSound power (3) dB(A) 86 87 87 88 88 88Sound pressure (4) dB(A) 54 55 55 56 56 55SIZEA (5) mm 4610 4610 5610 5610 5610 6610B (5) mm 2220 2220 2220 2220 2220 2220H (5) mm 2150 2420 2430 2430 2430 2430Operating weight (5) kg 3060 3570 4130 4240 4340 5210

Note:

1 Evaporator water (in/out) = 12/7°C; Condenser air (in) = 35°C.

2 Condenser water (in/out) = 40/45°C; evaporator air (in) = 7°C - r.h. 87%.

3 Sound power on the basis of measurements made in compliance with ISO 9614 and Eurovent 8/1 for Eurovent certified units; in compliance with ISO 3744 for non-certified units.

4 Average sound pressure level, at 10m distance, unit in a free field on a reflective surface; non-binding value obtained from the sound power level.

5 Unit in standard configuration/execution, without optional accessories

RECS / LTModels 1062 1162 1362 1562 1762 1962COOLING ONLYCooling capacity (1) kW 200 248 289 313 372 399Total power input (1) kW 74,5 88,7 104 113 134 148EER 2,68 2,80 2,78 2,77 2,78 2,70ESEER 3,19 3,38 3,25 3,36 3,32 3,34HEATING ONLYHeating capacity (2) kW 220 272 318 342 406 438Total power input (2) kW 74,6 90,5 108 112 136 147COP 2,95 3,01 2,94 3,05 2,99 2,98COMPRESSORSNo. Compressors/No. Circuits N. 2/2 2/2 2/2 2/2 2/2 2/2NOISE LEVELSSound power (3) dB(A) 97 97 97 98 99 99Sound pressure (4) dB(A) 65 65 65 66 66 66SIZEA (5) mm 4610 5610 5610 5610 6610 6610B (5) mm 2220 2220 2220 2220 2220 2220H (5) mm 2150 2430 2430 2430 2430 2430Operating weight (5) kg 3060 3840 4230 4240 4910 5210

Page 171: Products Guide V01 - ParagonEfficient project management thanks to Climaveneta as unique project leader. Complete and specialized Organization Climaveneta qualifies itself for the

169

Page 172: Products Guide V01 - ParagonEfficient project management thanks to Climaveneta as unique project leader. Complete and specialized Organization Climaveneta qualifies itself for the

170

Main accessoriesHydronic group

VPF (Variable Primary Flow) kit: variable flow pumps with on board regulation

Electronic expansion valve

Set-up for remote connectivity with ModBus/Echelon/Bacnet protocol cards

FeaturesHIGH EFFICIENCY

Unit in Class A as per Eurovent. High efficiency for low energy consumption during the operating hours

COMPACTNESS

Reduced dimensions, for easy installation even in sites with space´ constraints

EXTENSIVE RANGE OF OPERATION

Unit´s operation guaranteed with external air temperature down to -10°C during winter and up to 46°C during summer.

HOT WATER SUPPLY

Supply of hot water in use up to 55°C, offering maximum versatility with respect to different plant engineering solutions

Configurations- base function

D partial condensing heat recovery function

VersionsB base version

CA Class A of efficiency

LN-CA Low Noise, Class A of efficiency

SL-CA Super Low noise version, Class A of efficiency

CommandsW3000SE LargeThe W3000SE Large controller offers advanced functions and algorithms. The keypad features an easy-to-use interface and a complete LCD display, allowing to consult and intervene on the unit by means of a multi-level menu, with selectable language setting. The regulation features the continuous modulation of capacity, based on a dynamic dead band and referring to the leaving water temperature. As alternative, step-wise regulation is also available, referred to the return water temperature with selectable proportional- or proportional-integral logic. The diagnostics includes a complete alarm management, with the “black-box” and alarm logging functions for enhanced analysis of the unit operation. For multiple units systems, the regulation of the resources, via optional proprietary devices, can be implemented. Energy metering, for both consumption and capacity, can also be developed. Supervision can be easily developed via proprietary devices or the integration in third party systems by means of the most common protocols as ModBus, Bacnet, Bacnet-over-IP, Echelon LonWorks. Compatibility with the remote keyboard managing up to 10 units. Availability of an internal real time clock for operation scheduling (4-day profiles with 10 hour belts). The defrost adopts a proprietary self-adaptive logic, which features the monitoring of numerous operational parameters. This allows to reduce the number and duration of the defrost cycles, with a benefit for the overall energy efficiency.

Hydronic - reversible

FOCS-N 2022÷4822

Reversible unit, air source for outdoor installation

441 - 1162 kWUnit DescriptionOutdoor heat pump unit for the production of chilled/hot water with semi-hermetic screw compressors optimized for R134a, axial-flow fans, external coil with copper tubes and aluminium fines, shell and tubes heat exchangers designed by Climaveneta and thermostatic expansion valve. Base and supporting structure and panels are galvanized epoxy powder coated steel with increased thickness. These units are designed for two-pipes systems and are able to produce hot or cold water according to the selected operation mode; the precise thermoregulation guarantees an optimal response to load´s changes, in every operating conditions.

Page 173: Products Guide V01 - ParagonEfficient project management thanks to Climaveneta as unique project leader. Complete and specialized Organization Climaveneta qualifies itself for the

171

Note:

1 Evaporator water (in/out) = 12/7°C; Condenser air (in) = 35°C.

2 Condenser water (in/out) = 40/45°C; evaporator air (in) = 7°C - r.h. 87%.

3 Sound power on the basis of measurements made in compliance with ISO 9614 and Eurovent 8/1 for Eurovent certified units; in compliance with ISO 3744 for non-certified units.

4 Average sound pressure level, at 10m distance, unit in a free field on a reflective surface; non-binding value obtained from the sound power level.

5 Unit in standard configuration/execution, without optional accessories

FOCS-N / CAModels 2022 2222 2422 2622 2722 3222 3622 4222 4822COOLING ONLYCooling capacity (1) kW 459 503 538 586 672 803 928 1041 1162Total power input (1) kW 158 170 181 202 222 264 291 343 378EER 2,91 2,96 2,97 2,90 3,03 3,04 3,19 3,03 3,07ESEER * * * * * * * * *HEATING ONLYHeating capacity (2) kW 470 520 553 590 683 804 923 1051 1166Total power input (2) kW 143 156 167 177 202 238 265 309 341COP 3,29 3,33 3,31 3,33 3,38 3,38 3,48 3,40 3,42COMPRESSORSNo. Compressors/No. Circuits N. 2 / 2 2 / 2 2 / 2 2 / 2 2 / 2 2 / 2 2 / 2 2 / 2 2 / 2NOISE LEVELSSound power (3) dB(A) 99 101 101 101 101 102 102 104 104Sound pressure (4) dB(A) 67 69 69 69 69 70 70 72 72SIZEA (5) mm 4900 5800 5800 5800 7000 7900 10000 11800 11800B (5) mm 2260 2260 2260 2260 2260 2260 2260 2260 2260H (5) mm 2430 2430 2430 2430 2430 2430 2430 2430 2430Operating weight (5) kg * * * * * * * * *

Note:

1 Evaporator water (in/out) = 12/7°C; Condenser air (in) = 35°C.

2 Condenser water (in/out) = 40/45°C; evaporator air (in) = 7°C - r.h. 87%.

3 Sound power on the basis of measurements made in compliance with ISO 9614 and Eurovent 8/1 for Eurovent certified units; in compliance with ISO 3744 for non-certified units.

4 Average sound pressure level, at 10m distance, unit in a free field on a reflective surface; non-binding value obtained from the sound power level.

5 Unit in standard configuration/execution, without optional accessories

FOCS-N / BModels 2022 2222 2422 2622 2722 3222 3622 4222 4822COOLING ONLYCooling capacity (1) kW 450 494 531 572 663 791 916 1028 1146Total power input (1) kW 163 177 187 209 229 273 299 343 389EER 2,76 2,79 2,84 2,74 2,90 2,90 3,06 3,00 2,95ESEER * * * * * * * * *HEATING ONLYHeating capacity (2) kW 479 524 566 600 698 823 946 1072 1195Total power input (2) kW 152 166 178 188 215 252 283 322 363COP 3,15 3,16 3,18 3,19 3,25 3,27 3,34 3,33 3,29COMPRESSORSNo. Compressors/No. Circuits N. 2 / 2 2 / 2 2 / 2 2 / 2 2 / 2 2 / 2 2 / 2 2 / 2 2 / 2NOISE LEVELSSound power (3) dB(A) 99 101 101 101 101 102 102 104 104Sound pressure (4) dB(A) 67 69 69 69 69 70 70 72 72SIZEA (5) mm 4900 5800 5800 5800 7000 7900 10000 10000 11800B (5) mm 2260 2260 2260 2260 2260 2260 2260 2260 2260H (5) mm 2430 2430 2430 2430 2430 2430 2430 2430 2430Operating weight (5) kg * * * * * * * * *

COOLINGHEATING

r HFCR-134a

SCREWAXIALSHELL & TUBESENERGY CLASS

Page 174: Products Guide V01 - ParagonEfficient project management thanks to Climaveneta as unique project leader. Complete and specialized Organization Climaveneta qualifies itself for the

172

Minimum clearance required2022-4822

Switchboard side mm 1800Switchboard opposite side mm 1500Condensation coil side mm 2000

Note:

1 Evaporator water (in/out) = 12/7°C; Condenser air (in) = 35°C.

2 Condenser water (in/out) = 40/45°C; evaporator air (in) = 7°C - r.h. 87%.

3 Sound power on the basis of measurements made in compliance with ISO 9614 and Eurovent 8/1 for Eurovent certified units; in compliance with ISO 3744 for non-certified units.

4 Average sound pressure level, at 10m distance, unit in a free field on a reflective surface; non-binding value obtained from the sound power level.

5 Unit in standard configuration/execution, without optional accessories

FOCS-N / SL-CAModels 2022 2222 2422 2622 2722 3222 3622 4222 4822COOLING ONLYCooling capacity (1) kW 441 488 520 559 649 772 895 1004 1119Total power input (1) kW 163 172 185 209 227 271 293 346 385EER 2,71 2,84 2,81 2,67 2,86 2,85 3,05 2,90 2,91ESEER * * * * * * * * *HEATING ONLYHeating capacity (2) kW 461 514 546 578 674 794 911 1039 1151Total power input (2) kW 142 155 166 175 200 235 262 305 338COP 3,25 3,32 3,29 3,30 3,37 3,38 3,48 3,41 3,41COMPRESSORSNo. Compressors/No. Circuits N. 2 / 2 2 / 2 2 / 2 2 / 2 2 / 2 2 / 2 2 / 2 2 / 2 2 / 2NOISE LEVELSSound power (3) dB(A) 89 91 91 91 91 92 92 94 94Sound pressure (4) dB(A) 57 59 59 59 59 60 60 62 62SIZEA (5) mm 4900 5800 5800 5800 7000 7900 10000 11800 11800B (5) mm 2260 2260 2260 2260 2260 2260 2260 2260 2260H (5) mm 2430 2430 2430 2430 2430 2430 2430 2430 2430Operating weight (5) kg * * * * * * * * *

Note:

1 Evaporator water (in/out) = 12/7°C; Condenser air (in) = 35°C.

2 Condenser water (in/out) = 40/45°C; evaporator air (in) = 7°C - r.h. 87%.

3 Sound power on the basis of measurements made in compliance with ISO 9614 and Eurovent 8/1 for Eurovent certified units; in compliance with ISO 3744 for non-certified units.

4 Average sound pressure level, at 10m distance, unit in a free field on a reflective surface; non-binding value obtained from the sound power level.

5 Unit in standard configuration/execution, without optional accessories

FOCS-N / LN-CAModels 2022 2222 2422 2622 2722 3222 3622 4222 4822COOLING ONLYCooling capacity (1) kW 444 492 524 564 654 780 904 1013 1130Total power input (1) kW 160 169 182 205 224 267 290 342 380EER 2,78 2,91 2,88 2,75 2,92 2,92 3,12 2,96 2,97ESEER * * * * * * * * *HEATING ONLYHeating capacity (2) kW 467 520 553 586 683 804 923 1051 1166Total power input (2) kW 143 156 167 177 202 238 265 309 341COP 3,27 3,33 3,31 3,31 3,38 3,38 3,48 3,40 3,42COMPRESSORSNo. Compressors/No. Circuits N. 2 / 2 2 / 2 2 / 2 2 / 2 2 / 2 2 / 2 2 / 2 2 / 2 2 / 2NOISE LEVELSSound power (3) dB(A) 93 95 95 95 95 96 96 98 98Sound pressure (4) dB(A) 61 63 63 63 63 64 64 66 66SIZEA (5) mm 4900 5800 5800 5800 7000 7900 10000 10000 11800B (5) mm 2260 2260 2260 2260 2260 2260 2260 2260 2260H (5) mm 2430 2430 2430 2430 2430 2430 2430 2430 2430Operating weight (5) kg * * * * * * * * *

Page 175: Products Guide V01 - ParagonEfficient project management thanks to Climaveneta as unique project leader. Complete and specialized Organization Climaveneta qualifies itself for the

173

Page 176: Products Guide V01 - ParagonEfficient project management thanks to Climaveneta as unique project leader. Complete and specialized Organization Climaveneta qualifies itself for the

174

Main accessoriesSet-up for remote connectivity with ModBus/Echelon/Bacnet protocol cards

Remote keyboard (distance to 200m and to 500m)

Soft starters

Horizontal or vertical air outflow

Rubber anti-vibration mounting kit

FeaturesREFRIGERANT GAS R410A

The use of R410A has resulted in units offering better energy efficiency in full respect for the environment (ODP = 0)

TOTAL VERSATILITY

The NECS-CN units are available with both vertical and horizontal air outflow. The horizontal outflow version is particularly effective in installations where the height of the technical compartment does not allow the traditional vertical outflow

HIGH PERFORMANCE CENTRIFUGAL FANS

The units are fitted with statically and dynamically balanced double-inlet centrifugal fans coupled by belt and pulleys. Useful static pressure up to 180 Pa.

INTEGRATED HYDRONIC MODULE

The built-in hydronic module includes the main water circuit components; it is available in various configurations with one or two pumps with high or low head.

Configurations- base function

D partial condensing heat recovery function

VersionsB base version

CommandsW3000 Base / W3000SE CompactThe controller can be chosen as: - W3000 Base: keypad and LED display - W3000SE Compact: the keypad features an easy-to-use interface and a complete LCD display, allowing to consult and intervene on the unit by means of a multi-level menu, with selectable language setting. The diagnostics includes a complete alarm management, with the “black-box” and alarm logging functions for enhanced analysis of the unit operation. Compatibility with the remote keyboard managing up to 10 units. Availability of an internal real time clock for operation scheduling (4-day profiles with 10 hour belts). Common features: The regulation is based on the exclusive QuickMind algorithm, including self-adaptive control logics, beneficial in low water content systems. As alternatives the proportional- or proportional-integral regulations are also available. For multiple units systems, the regulation of the resources, via optional proprietary devices, can be implemented. Energy metering, for both consumption and capacity, can also be developed. Supervision can be easily developed via proprietary devices or the integration in third party systems by means of the most common protocols as ModBus, Bacnet, Bacnet-over-IP, Echelon LonWorks.

Hydronic - reversible

NECS-CN 0152÷1204

Reversible unit, air source for indoor installation

36,0 - 303 kWUnit DescriptionIndoor unit with heat pump for the production of chilled/hot water with hermetic rotary Scroll compressors, centrifugal fans, braze-welded plate-type exchanger and thermal expansion valve. External panels in pre-clad sheet steel (simil Pereluman) and base in galvanised steel with paint finish. The range includes the single-circuit two-compressor versions and the dual circuit four-compressor versions.

Page 177: Products Guide V01 - ParagonEfficient project management thanks to Climaveneta as unique project leader. Complete and specialized Organization Climaveneta qualifies itself for the

175

Minimum clearance required0152-1204

Switchboard side mm 1000Switchboard opposite side mm 1000Condensation coil side mm 2000

Note:

1 Evaporator water (in/out) = 12/7°C; Condenser air (in) = 35°C.

2 Condenser water (in/out) = 40/45°C; evaporator air (in) = 7°C - r.h. 87%.

3 Evaporator water (in/out) = 12/7°C; Condenser air (in) = 35°C. Desuperheater water (in/out) = 40/45°C.

4 Useful pressure to be specified at the time of placing the order.

5 Total sound power of the fans as declared by the manufacturer referred to nominal speed of rotation and useful static head of 120 Pa on delivery side.

6 Unit in standard configuration/execution, without optional accessories

Models 0552 0612 0604 0704 0804 0904 1004 1104 1204COOLING ONLYCooling capacity (1) kW 137 154 146 164 187 213 237 274 303Total power input (1) kW 58,0 64,0 60,0 72,0 79,0 87,0 100 113 131EER 2,60 2,61 2,64 2,47 2,59 2,64 2,57 2,64 2,50 ESEER 3,81 3,76 3,90 3,71 3,88 4,00 3,62 3,70 3,60 HEATING ONLYHeating capacity (2) kW 153 173 165 185 208 235 261 302 336Total power input (2) kW 55,0 62,0 58,0 66,0 74,0 83,0 94,0 108 122COP 3,06 3,06 3,12 3,03 3,06 3,09 3,01 3,06 2,97 COOLING WITH PARTIAL RECOVERYCooling capacity (3) kW 142 160 152 170 194 221 246 284 315Total power input (3) kW 56,2 62,5 58,5 69,5 76,6 84,5 96,9 109 127Desuperheater heating capacity (3) kW 43,1 48,7 46,4 55,1 60,9 67,8 75,6 85,9 99,7COMPRESSORSNo. Compressors/No. Circuits N. 2/1 2/1 4/2 4/2 4/2 4/2 4/2 4/2 4/2 FANSFan air flow m3/h 47988 47988 45000 47988 60012 60012 68004 79992 84996Max AESP (4) Pa 120 120 120 120 120 120 120 120 120 NOISE LEVELSSound power (5) dB(A) 94 94 92 94 94 94 96 96 97SIZEA (6) mm 3602 3602 3602 3602 4602 4602 4602 5602 5602B (6) mm 1104 1104 1277 1277 1277 1277 1277 1277 1277H (6) mm 1927 1927 1900 1900 2235 2235 2235 2235 2235Operating weight (6) kg 1600 1660 1980 2055 2475 2630 2725 3145 3205

NECS-CN / BModels 0152 0182 0202 0252 0302 0352 0412 0452 0512COOLING ONLYCooling capacity (1) kW 36,0 42,0 49,0 55,0 73,0 84,0 95,0 107 119Total power input (1) kW 15,0 17,0 20,0 22,0 31,0 35,0 39,0 44,0 50,0EER 2,76 2,78 2,75 2,70 2,62 2,65 2,66 2,66 2,61 ESEER 4,65 4,48 4,48 4,36 3,85 3,95 3,92 3,98 3,74 HEATING ONLYHeating capacity (2) kW 42,0 48,0 56,0 64,0 82,0 95,0 107 122 135Total power input (2) kW 15,0 17,0 19,0 22,0 30,0 34,0 38,0 42,0 47,0COP 3,24 3,22 3,21 3,15 3,08 3,11 3,12 3,16 3,10 COOLING WITH PARTIAL RECOVERYCooling capacity (3) kW 37,8 43,9 50,9 57,4 75,7 87,3 98,5 111 124Total power input (3) kW 14,4 16,6 19,1 21,7 30,3 34,0 37,9 42,5 48,0Desuperheater heating capacity (3) kW 11,9 13,3 15,7 17,9 23,2 26,4 29,8 33,6 37,4COMPRESSORSNo. Compressors/No. Circuits N. 2/1 2/1 2/1 2/1 2/1 2/1 2/1 2/1 2/1 FANSFan air flow m3/h 15012 16992 16992 16992 29988 29988 29988 32004 34992Max AESP (4) Pa 120 120 120 120 120 120 120 120 120 NOISE LEVELSSound power (5) dB(A) 81 83 83 83 90 90 90 92 94SIZEA (6) mm 2200 2200 2200 2200 2602 2602 2602 3602 3602B (6) mm 920 920 920 920 1104 1104 1104 1104 1104H (6) mm 1642 1642 1642 1642 1927 1927 1927 1927 1927Operating weight (6) kg 720 730 750 790 1080 1170 1230 1470 1490

COOLINGHEATING

r HFCR-410A

SCROLLCENTRIFUGALPLATES

AB

H

Page 178: Products Guide V01 - ParagonEfficient project management thanks to Climaveneta as unique project leader. Complete and specialized Organization Climaveneta qualifies itself for the

176

Main accessoriesSet-up for remote connectivity with ModBus/Echelon/Bacnet protocol cardsCondensing control device: two or three-way modulating pressure-controlled valve and inverter on pumpsWater connections directed upwards (for 2 compressors units only)

Acoustical enclosure to reduce the noise emissions.

Rubber anti-vibration mounting kit. Spring anti-vibration mounting kit (4 compressors models only)

FeaturesREFRIGERANT GAS R410A

The use of R410A has resulted in units offering better energy efficiency in full respect for the environment (ODP = 0)

TOTAL VERSATILITY

Climaveneta has designed the NECS-W units with a range of integral accessories in mind for operation with total water loss (well, water bed, etc.), dry cooler or cooling tower so as to satisfy all service system and installation requirements.INTEGRATED HYDRONIC MODULE ON COOLER/CONDENSER SIDEThe built-in hydronic module includes the main water circuit components; it is available in various configurations with one or two pumps with high or low head both on the evaporator and the condenser side.

INTEGRATED CONDENSATION´S CONTROL

The electronics of the units manages the most suitable condensing control for each type of application: pressure-controlled valve, two or three-way modulating valve and inverter control for the pumps

VersionsB base version

CommandsW3000 Base / W3000SE CompactThe controller can be chosen as: - W3000 Base: keypad and LED display - W3000SE Compact: the keypad features an easy-to-use interface and a complete LCD display, allowing to consult and intervene on the unit by means of a multi-level menu, with selectable language setting. The diagnostics includes a complete alarm management, with the “black-box” and alarm logging functions for enhanced analysis of the unit operation. Compatibility with the remote keyboard managing up to 10 units. Availability of an internal real time clock for operation scheduling (4-day profiles with 10 hour belts). Common features: The regulation is based on the exclusive QuickMind algorithm, including self-adaptive control logics, beneficial in low water content systems. As alternatives the proportional- or proportional-integral regulations are also available. For multiple units systems, the regulation of the resources, via optional proprietary devices, can be implemented. Energy metering, for both consumption and capacity, can also be developed. Supervision can be easily developed via proprietary devices or the integration in third party systems by means of the most common protocols as ModBus, Bacnet, Bacnet-over-IP, Echelon LonWorks.

Hydronic - reversible

NECS-WN 0152÷1204

Reversible unit, water source

43,4 - 371 kWUnit DescriptionWater-cooled indoor unit for the production of chilled/hot water with hermetic rotary Scroll compressors, braze-welded plate-type exchanger and thermal expansion valve. External panels in pre-clad sheet steel (simil-Peraluman) and structure in galvanised steel with paint finish. The range includes the single-circuit two-compressor versions and the dual circuit four-compressor versions.

Page 179: Products Guide V01 - ParagonEfficient project management thanks to Climaveneta as unique project leader. Complete and specialized Organization Climaveneta qualifies itself for the

177

Minimum clearance required0152-0612 0604-1204

Switchboard side mm 800 1000Switchboard opposite side mm 600 1000Unit's side mm 600 1000

Note:

1 Evaporator water (in/out) = 12/7°C, condenser water (in/out) = 30/35°C, based on Eurovent Standard

2 Evaporator water (in/out) = 12/7°C; Condenser water (in/out) = 40/45°C.

3 Sound power on the basis of measurements made in compliance with ISO 9614 and Eurovent 8/1 for Eurovent certified units; in compliance with ISO 3744 for non-certified units.

4 Sound pressure in open field conditions on reflecting surface (directivity factor Q=2), average value on longest side, at 1 m from the outer surface and at 1 m height in relation to the unit supporting base.

5 Unit in standard configuration/execution, without optional accessories

Models 0552 0612 0604 0704 0804 0904 1004 1104 1204COOLING ONLYCooling capacity (1) kW 165 186 174 203 228 258 288 329 371 Total power input (1) kW 36,9 41,6 38,9 45,2 51,6 58,0 64,0 74,0 83,5 Condernser heating capacity (1) 200 225 211 245 276 312 348 398 450 EER 4,47 4,48 4,47 4,48 4,42 4,45 4,50 4,44 4,44 ESEER 5,90 5,80 5,80 5,90 5,80 5,90 5,90 6,00 5,90 HEATING ONLYHeating capacity (2) kW 190 215 202 234 263 297 332 379 428 Total power input (2) kW 45,9 51,8 49,2 56,6 64,1 72,1 79,5 91,9 104 COP (2) 4,14 4,14 4,11 4,13 4,10 4,12 4,17 4,13 4,12 COMPRESSORSNo. Compressors/No. Circuits N. 2/1 2/1 4/2 4/2 4/2 4/2 4/2 4/2 4/2 NOISE LEVELSSound power (3) dB(A) 79 79 86 87 88 89 90 91 91 Sound pressure (4) dB(A)SIZEA (5) mm 1222 1222 2227 2227 2227 2227 2227 2227 2227 B (5) mm 873 873 877 877 877 877 877 877 877H (5) mm 1496 1496 1780 1780 1780 1780 1780 1780 1780 Operating weight (5) kg 790 830 1090 1165 1245 1290 1395 1500 1585

NECS-WN / BModels 0152 0182 0202 0252 0262 0302 0352 0412 0452 0512COOLING ONLYCooling capacity (1) kW 43,4 50,1 58,9 66,4 72,6 86,7 101 115 129 144 Total power input (1) kW 10,0 11,3 13,0 15,2 16,6 19,5 22,7 25,9 28,9 32,2 Condernser heating capacity (1) 52,8 60,7 71,2 80,7 88,2 105 123 139 156 174 EER 4,34 4,43 4,53 4,37 4,37 4,45 4,46 4,43 4,45 4,46 ESEER 5,80 6,00 6,00 5,70 5,60 5,70 5,80 5,70 5,80 5,80 HEATING ONLYHeating capacity (2) kW 50,5 58,2 68,0 77,0 85,0 101 117 132 148 165 Total power input (2) kW 12,9 14,3 16,7 19,2 21,1 24,7 28,7 32,2 36,0 40,0 COP (2) 3,91 4,07 4,07 4,01 4,03 4,09 4,07 4,10 4,12 4,14 COMPRESSORSNo. Compressors/No. Circuits N. 2/1 2/1 2/1 2/1 2/1 2/1 2/1 2/1 2/1 2/1 NOISE LEVELSSound power (3) dB(A) 73 74 74 74 75 76 77 77 78 78 Sound pressure (4) dB(A)SIZEA (5) mm 1055 1055 1055 1055 1055 1222 1222 1222 1222 1222 B (5) mm 649 649 649 649 649 843 843 843 843 843H (5) mm 1255 1255 1255 1255 1255 1496 1496 1496 1496 1496 Operating weight (5) kg 290 305 315 325 330 585 605 660 685 740

COOLINGHEATING

r HFCR-410A

SCROLLPLATES

H

BA

H

B A

Page 180: Products Guide V01 - ParagonEfficient project management thanks to Climaveneta as unique project leader. Complete and specialized Organization Climaveneta qualifies itself for the

178

Main accessoriesIntegral acoustical enclosure (type base or plus)

Electronic expansion valve

Remote keyboard

Set-up for remote connectivity with ModBus, Echelon LonTalk, Trend, Bacnet protocol board.

FeaturesSILENT OPERATION

If compared to the solution of a water condensed unit reversible on the hydronic side, these units allows a reduction in the required technical space and, moreover, an appreciable simplification in the plant´s design.

INTEGRATED CONDENSATION´S CONTROL

A 2 way valve is supplied as standard for the condensing pressure control. For all the applications in which a constant waterflow through the condenser is needed, a 3-way valve option is also available under request.

ADAPTABILITY

Adaptability at the buildings cooling request thanks to the continuous capacity regulation, assured by sophisticated controls logic

SILENT OPERATION

Extremely silent operation thanks to the accurate units design. Optional integral acoustic enclosure, reduces more the sound level beyond the best on market

Configurations- base function

D partial condensing heat recovery function

VersionsB base version

CommandsW3000SE LargeThe W3000 SE Large controller offers advanced functions and algorithms. The keypad is generously sized with full operating status display. The commands and detailed LCD display make access to the units settings easy and safe. These resources allow to consult and intervene on the unit by means of a multi-level menu, with selectable language setting. The diagnostics includes a complete alarm management, with the “black-box” and alarm logging functions for enhanced analysis of the unit operation. For multiple units systems, the regulation of the resources, via optional proprietary devices, can be implemented. Energy metering, for both consumption and capacity, can also be developed. Supervision can be easily developed via proprietary devices or the integration in third party systems by means of the most common protocols as ModBus, Bacnet, Bacnet-over-IP, Echelon LonWorks. Compatibility with the remote keyboard managing up to 10 units. Availability of an internal real time clock for operation scheduling (4-day profiles with 10 hour belts). The regulation features the continuous modulation of capacity, based on a dynamic dead band and referring to the leaving water temperature. As alternative, step-wise regulation is also available, referred to the return water temperature with selectable proportional- or proportional-integral logic.

Hydronic - reversible

RECS-W 0802÷3202

Reversible unit, water source

174 - 801 kWUnit DescriptionIndoor heat pump unit for the production of chilled/hot water with semi-hermetic screw compressors optimized for R134a, thermostatic expansion valve, shell and tube condenser and evaporator. Base and supporting structure and panels are of galvanized epoxy powder coated steel with increased thickness. Flexible and reliable unit; it easily adapts itself to different thermal load conditions thanks to the precise thermoregulation. The high performances level is achieved thanks to the accurate sizing of all internal components.

Page 181: Products Guide V01 - ParagonEfficient project management thanks to Climaveneta as unique project leader. Complete and specialized Organization Climaveneta qualifies itself for the

179

Minimum clearance required0802-1702 1902-3202

Switchboard side mm 800 1500Switchboard opposite side mm 0 0Condensation coil side mm 0 0Cooler water connections side (minimum)

mm 500 900

Condenser water connections side mm 500 900Condenser water fittings opposite side (minimum)

mm 500 900

Note:

1 Evaporator water (in/out) = 12/7°C, condenser water (in/out) = 30/35°C, based on Eurovent Standard

2 Evaporator water (in/out): 12/7°C; Condenser water (in/out): 30/35°C; Desuperheater water (in/out): 40/45°C.

3 Evaporator water (in/out) = 12/7°C; Condenser water (in/out) = 40/45°C.

4 Sound power on the basis of measurements made in compliance with ISO 9614 and Eurovent 8/1 for Eurovent certified units; in compliance with ISO 3744 for non-certified units.

5 Sound pressure in open field conditions on reflecting surface (directivity factor Q=2), average value on longest side, at 1 m from the outer surface and at 1 m height in relation to the unit supporting base.

6 Unit in standard configuration/execution, without optional accessories

RECS-W / BModels 0802 1002 1102 1302 1502 1702 1902 2152 2502 2602 2702 3202COOLING ONLYCooling capacity (1) kW 174 213 246 292 334 379 429 499 583 631 703 800Total power input (1) kW 39,3 49,2 55,8 65,6 75,2 88,5 98,9 109 128 137 154 176Condernser heating capacity (1) 211 259 298 354 404 462 522 602 703 760 848 966EER 4,43 4,33 4,41 4,46 4,44 4,28 4,34 4,57 4,57 4,61 4,56 4,55ESEER 5,31 5,43 5,13 5,40 5,57 5,31 5,51 5,75 5,58 5,50 5,54 5,67COOLING WITH PARTIAL RECOVERY (only -D)Cooling capacity (2) kW 181 221 255 303 346 393 445 518 605 655 729 831Total power input (2) kW 38 47 54 63 73 85 95 105 123 132 149 170Desuperheater heating capacity (2) kW 17 21 24 28 32 38 43 47 55 59 67 76HEATING ONLYHeating capacity (3) kW 199 245 283 334 381 436 496 571 665 715 806 912Total power input (3) kW 47,1 58,7 67,9 78,6 89,5 107 120 132 153 162 185 211COP (3) 4,23 4,17 4,16 4,25 4,26 4,09 4,13 4,32 4,35 4,40 4,35 4,32COMPRESSORSNo. Compressors/No. Circuits N. 2 / 2 2 / 2 2 / 2 2 / 2 2 / 2 2 / 2 2 / 2 2 / 2 2 / 2 2 / 2 2 / 2 2 / 2NOISE LEVELSSound power (4) dB(A) 94 95 97 97 97 97 97 98 99 99 99 99Sound pressure (5) dB(A) * * * * * * * * * * * *SIZEA (6) mm 3680 3680 3680 3680 3680 3680 3800 3800 3800 4800 4800 4800B (6) mm 1170 1170 1170 1170 1170 1170 1240 1240 1240 1240 1240 1240H (6) mm 1890 1890 1890 1890 1890 1890 1950 1950 1950 2050 2050 2050Operating weight (6) kg 1990 2070 2490 2940 3020 3060 4080 4460 4840 5390 5490 6340

COOLINGHEATING

r HFCR-134a

SCREWSHELL & TUBES

H

BA

Page 182: Products Guide V01 - ParagonEfficient project management thanks to Climaveneta as unique project leader. Complete and specialized Organization Climaveneta qualifies itself for the

180

Main accessoriesSet-up for remote connectivity with ModBus/Echelon/Bacnet protocol cards

Remote keyboard (distance to 200m and to 500m)

Soft starters

Rubber anti-vibration mounting kit

FeaturesTOTAL VERSATILITY

Unique proposal: unit designed to satisfy, according to the mode of operation, requirements of cold water, hot water for heating or hot water for domestic use

EXTENSIVE RANGE OF OPERATION

Extensive range of operation with external air temperature up to 46°C in summer and down to -10°C in winter with LT version

HOT WATER SUPPLY

Production of domestic hot water up to 52°C in both summer and winter operating conditions, offering maximum versatility with respect to different plant engineering solutions

INTEGRATED HYDRONIC MODULE

The built-in hydronic module already contains the main water circuit components; it is available with single or twin in-line pump, for achieving both low or high head, available for both plant and recovery circuits (up to 4 pumps).

VersionsB base version

LN low noise version

SL super-low noise version

CommandsW3000SE LargeThe W3000SE Large controller offers advanced functions and algorithms. The keypad features an easy-to-use interface and a complete LCD display, allowing to consult and intervene on the unit by means of a multi-level menu, with selectable language setting. The regulation operates on both water circuits featuring the step-wise regulation referred to the return water temperature with proportional logic. This allows to satisfy simultaneously the different requests of both cooling and heating, according to the selected operation mode. The diagnostics includes a complete alarm management, with the “black-box” and alarm logging functions for enhanced analysis of the unit operation. For multiple units systems, the regulation of the resources, via optional proprietary devices, can be implemented. Energy metering, for both consumption and capacity, can also be developed. Supervision can be easily developed via proprietary devices or the integration in third party systems by means of the most common protocols as ModBus, Bacnet, Bacnet-over-IP, Echelon LonWorks. Compatibility with the remote keyboard managing up to 10 units. Availability of an internal real time clock for operation scheduling (4-day profiles with 10 hour belts). The defrost adopts a proprietary self-adaptive logic, which features the monitoring of numerous operational parameters. This allows to reduce the number and duration of the defrost cycles, with a benefit for the overall energy efficiency.

Hydronic - reversible

NECS-NR 0152÷1204

Reversible unit, NRG line, total heat recovery, air source for outdoor installation

36 - 311 kWUnit DescriptionAir-cooled reversible unit with total heat recovery for the simultaneous production of chilled/hot water with hermetic rotary Scroll compressors, with R410A, axial fans, braze-welded plate-type exchanger and thermal expansion valve. External panels in Peraluman and base in galvanised sheet steel with paint finish. The range includes the two-compressor and the four-compressor versions, both with two circuits.

Page 183: Products Guide V01 - ParagonEfficient project management thanks to Climaveneta as unique project leader. Complete and specialized Organization Climaveneta qualifies itself for the

181

Note:

1 Evaporator water (in/out) = 12/7°C; Condenser air (in) = 35°C.

2 Condenser water (in/out) = 40/45°C; evaporator air (in) = 7°C - r.h. 87%.

3 Evaporator water (in/out) = 12/7°C; Recovery unit water (in/out) = 40/45°C

4 Sound power on the basis of measurements made in compliance with ISO 9614 and Eurovent 8/1 for Eurovent certified units; in compliance with ISO 3744 for non-certified units.

5 Average sound pressure level, at 10m distance, unit in a free field on a reflective surface; non-binding value obtained from the sound power level.

6 Unit in standard configuration/execution, without optional accessories

Models 0612 0604 0704 0804 0904 1004 1104 1204COOLING ONLYCooling capacity (1) kW 151 150 166 189 211 240 277 311Total power input (1) kW 56,6 58,9 69 75,8 85,2 95,6 107 121EER 2,66 2,54 2,41 2,49 2,48 2,51 2,58 2,58ESEERHEATING ONLYHeating capacity (2) kW 173 167 185 209 234 267 306 344Total power input (2) kW 52,1 58 64,9 72,1 79,8 92 104 116COP 3,31 2,88 2,86 2,90 2,93 2,90 2,94 2,96COOLING WITH TOTAL RECOVERYCooling capacity (3) kW 160 151 173 194 220 246 281 317Total power input (3) kW 51,3 198 226 255 288 321 368 415Heat recovery capacity (3) kW 208 49,8 57,1 64,5 72,1 79,8 92,8 105COMPRESSORSNo. Compressors/No. Circuits N. 2/2 4/2 4/2 4/2 4/2 4/2 4/2 4/2NOISE LEVELSSound power (4) dB(A) 87 93 92 92 93 94 95 95Sound pressure (5) dB(A) 55 60 60 60 61 62 63 63SIZEA (6) mm 3570 3110 3110 3110 4110 4110 4110 4110B (6) mm 1300 2220 2220 2220 2220 2220 2220 2220H (6) mm 1620 2150 2150 2150 2150 2150 2150 2150Operating weight (6) kg 1290 1600 1840 2120 2320 2480 2680 2860

NECS-NR / BModels 0152 0182 0202 0252 0262 0302 0412 0512COOLING ONLYCooling capacity (1) kW 36,6 43,2 48,5 55,8 61,2 73,3 94,8 120Total power input (1) kW 13,3 14,5 17,9 19,9 22,8 26,2 33,6 41,7EER 2,76 2,99 2,71 2,80 2,68 2,80 2,82 2,88ESEERHEATING ONLYHeating capacity (2) kW 41,1 48,9 55,3 62,5 68,1 83,1 107 136Total power input (2) kW 13,3 14,7 17,2 19,7 21,4 24,9 32,1 40COP 3,10 3,33 3,22 3,17 3,18 3,34 3,34 3,40COOLING WITH TOTAL RECOVERYCooling capacity (3) kW 37,2 43,6 50,6 57,2 64,1 76,3 97,7 124Total power input (3) kW 12,8 14,2 16,6 18,9 21 24,5 31,9 39,6Heat recovery capacity (3) kW 49,2 56,9 66,2 75 83,8 99,3 128 161COMPRESSORSNo. Compressors/No. Circuits N. 2/2 2/2 2/2 2/2 2/2 2/2 2/2 2/2NOISE LEVELSSound power (4) dB(A) 84 84 84 84 84 85 86 87Sound pressure (5) dB(A) 52 52 52 52 52 53 54 55SIZEA (6) mm 2020 2020 2020 2520 2520 2520 3070 3570B (6) mm 1300 1300 1300 1300 1300 1300 1300 1300H (6) mm 1620 1620 1620 1620 1620 1620 1620 1620Operating weight (6) kg 570 590 600 660 670 720 1030 1180

r HFCR-410A

SCROLLAXIALPLATES

Page 184: Products Guide V01 - ParagonEfficient project management thanks to Climaveneta as unique project leader. Complete and specialized Organization Climaveneta qualifies itself for the

182

Note:

1 Evaporator water (in/out) = 12/7°C; Condenser air (in) = 35°C.

2 Condenser water (in/out) = 40/45°C; evaporator air (in) = 7°C - r.h. 87%.

3 Evaporator water (in/out) = 12/7°C; Recovery unit water (in/out) = 40/45°C

4 Sound power on the basis of measurements made in compliance with ISO 9614 and Eurovent 8/1 for Eurovent certified units; in compliance with ISO 3744 for non-certified units.

5 Average sound pressure level, at 10m distance, unit in a free field on a reflective surface; non-binding value obtained from the sound power level.

6 Unit in standard configuration/execution, without optional accessories

NECS-NR / LNModels 0604 0704 0804 0904 1004 1104 1204COOLING ONLYCooling capacity (1) kW 143 157 177 199 227 261 291Total power input (1) kW 58,8 70,2 78,4 87,8 96,5 110 125EER 2,43 2,24 2,26 2,27 2,36 2,37 2,32ESEERHEATING ONLYHeating capacity (2) kW 160 176 198 225 254 290 324Total power input (2) kW 54 60,8 67,9 75,7 85,8 97,9 110COP 2,95 2,89 2,92 2,98 2,95 2,96 2,94COOLING WITH TOTAL RECOVERYCooling capacity (3) kW 151 173 194 220 246 281 317Total power input (3) kW 198 226 255 288 321 368 415Heat recovery capacity (3) kW 49,8 57,1 64,5 72,1 79,8 92,8 105COMPRESSORSNo. Compressors/No. Circuits N. 4/2 4/2 4/2 4/2 4/2 4/2 4/2NOISE LEVELSSound power (4) dB(A) 86 86 86 87 88 89 89Sound pressure (5) dB(A) 54 54 54 55 56 57 57SIZEA (6) mm 3110 3110 3110 4110 4110 4110 4110B (6) mm 2220 2220 2220 2220 2220 2220 2220H (6) mm 2150 2150 2150 2150 2150 2150 2150Operating weight (6) kg 1600 1840 2120 2320 2480 2680 2860

Page 185: Products Guide V01 - ParagonEfficient project management thanks to Climaveneta as unique project leader. Complete and specialized Organization Climaveneta qualifies itself for the

183

Minimum clearance required0152-1204

Switchboard side mm 1100Switchboard opposite side mm 1100Condensation coil side mm 2000

Note:

1 Evaporator water (in/out) = 12/7°C; Condenser air (in) = 35°C.

2 Condenser water (in/out) = 40/45°C; evaporator air (in) = 7°C - r.h. 87%.

3 Evaporator water (in/out) = 12/7°C; Recovery unit water (in/out) = 40/45°C

4 Sound power on the basis of measurements made in compliance with ISO 9614 and Eurovent 8/1 for Eurovent certified units; in compliance with ISO 3744 for non-certified units.

5 Average sound pressure level, at 10m distance, unit in a free field on a reflective surface; non-binding value obtained from the sound power level.

6 Unit in standard configuration/execution, without optional accessories

Models 0612 0604 0704 0804 0904 1004 1104 1204COOLING ONLYCooling capacity (1) kW 143 142 160 183 201 225 261 294Total power input (1) kW 60,4 58 67,4 75,5 87,3 95,5 108 123EER 2,37 2,45 2,37 2,43 2,30 2,36 2,41 2,38ESEERHEATING ONLYHeating capacity (2) kW 169 159 178 205 226 253 295 330Total power input (2) kW 52 52,6 59,5 68,7 76,1 83,8 96,1 110COP 3,26 3,02 2,99 2,99 2,98 3,02 3,07 3COOLING WITH TOTAL RECOVERYCooling capacity (3) kW 160 151 173 194 220 246 281 317Total power input (3) kW 51,3 198 226 255 288 321 368 415Heat recovery capacity (3) kW 208 49,8 57,1 64,5 72,1 79,8 92,8 105COMPRESSORSNo. Compressors/No. Circuits N. 2/2 4/2 4/2 4/2 4/2 4/2 4/2 4/2NOISE LEVELSSound power (4) dB(A) 83 82 82 83 83 83 85 86Sound pressure (5) dB(A) 51 50 50 51 51 51 53 54SIZEA (6) mm 3570 3110 3110 4110 4110 4110 5110 5110B (6) mm 1300 2220 2220 2220 2220 2220 2220 2220H (6) mm 1620 2150 2150 2150 2150 2150 2150 2150Operating weight (6) kg 1290 1700 1960 2350 2420 2590 2950 3100

NECS-NR / SLModels 0152 0182 0202 0252 0262 0302 0412 0512COOLING ONLYCooling capacity (1) kW 33,3 39,6 47 50,9 58,3 69,1 93,9 119Total power input (1) kW 15 16,5 18,7 22,4 24,4 28,4 34,1 42,3EER 2,21 2,39 2,52 2,28 2,39 2,43 2,75 2,81ESEERHEATING ONLYHeating capacity (2) kW 40 47,4 55,1 60,9 70,5 80,9 109 138Total power input (2) kW 13,1 14,6 17,2 19,7 21,5 24,8 32,2 40,1COP 3,04 3,24 3,21 3,10 3,28 3,26 3,38 3,43COOLING WITH TOTAL RECOVERYCooling capacity (3) kW 37,2 43,6 50,6 57,2 64,1 76,3 97,7 124Total power input (3) kW 12,8 0 16,6 18,9 21 24,5 31,9 39,6Heat recovery capacity (3) kW 49,2 56,9 66,2 74,9 83,8 99,3 128 161COMPRESSORSNo. Compressors/No. Circuits N. 2/2 2/2 2/2 2/2 2/2 2/2 2/2 2/2NOISE LEVELSSound power (4) dB(A) 78 78 79 79 79 80 82 83Sound pressure (5) dB(A) 46 46 47 47 47 48 50 51SIZEA (6) mm 2020 2020 2520 2520 2520 3070 3070 3570B (6) mm 1300 1300 1300 1300 1300 1300 1300 1300H (6) mm 1620 1620 1620 1620 1620 1620 1620 1620Operating weight (6) kg 570 590 660 660 700 780 1070 1230

A

B

H

AB

H

Page 186: Products Guide V01 - ParagonEfficient project management thanks to Climaveneta as unique project leader. Complete and specialized Organization Climaveneta qualifies itself for the

184

Main accessoriesRemote keyboard (distance to 200m and to 500m)

Soft starters

Set-up for remote connectivity with ModBus, Echelon LonTalk, Bacnet protocol boardLT kit for extending the operating limits in heat pump mode down to -10°C (/SL-CA versions) and -12°C (/CA versions)

FeaturesREFRIGERANT GAS R410A

The use of R410A has resulted in units offering better energy efficiency in full respect for the environment (ODP = 0)

HOT WATER SUPPLY

Production of domestic hot water up to 55°C in both summer and winter operating conditions, offering maximum versatility with respect to different plant engineering solutions.

CLASS A EFFICIENCY

The full range is also available with the Class A efficiency rating. NECS-NR/CA and NECS-NR/SL-CA guaranty premium levels of efficiency thanks to the generous sizing of the refrigerant-exchange surface areas and to an accurate control of the fans, available on both standard and low-noise versions.

INTEGRATED HYDRONIC MODULE

The built-in hydronic module already contains the main water circuit components; it is available with single or twin in-line pump, for achieving both low or high head, available for both plant and recovery circuits (up to 4 pumps).

VersionsB base version

CA Class A of efficiency

SL-CA Super Low noise version, Class A of efficiency

CommandsW3000SE LargeThe W3000SE Large controller offers advanced functions and algorithms. The keypad features an easy-to-use interface and a complete LCD display, allowing to consult and intervene on the unit by means of a multi-level menu, with selectable language setting. The regulation operates on both water circuits featuring the step-wise regulation referred to the return water temperature with proportional logic. This allows to satisfy simultaneously the different requests of both cooling and heating, according to the selected operation mode. The diagnostics includes a complete alarm management, with the “black-box” and alarm logging functions for enhanced analysis of the unit operation. For multiple units systems, the regulation of the resources, via optional proprietary devices, can be implemented. Energy metering, for both consumption and capacity, can also be developed. Supervision can be easily developed via proprietary devices or the integration in third party systems by means of the most common protocols as ModBus, Bacnet, Bacnet-over-IP, Echelon LonWorks. Compatibility with the remote keyboard managing up to 10 units. Availability of an internal real time clock for operation scheduling (4-day profiles with 10 hour belts). The defrost adopts a proprietary self-adaptive logic, which features the monitoring of numerous operational parameters. This allows to reduce the number and duration of the defrost cycles, with a benefit for the overall energy efficiency.

Hydronic - reversible

NECS-NR 1314÷3218

Reversible unit, NRG line, total heat recovery, air source for outdoor installation

353 - 823 kWUnit DescriptionAir-cooled reversible unit with total heat recovery for the simultaneous production of chilled/hot water with hermetic rotary Scroll compressors, with R410A, axial fans, shell and tube heat exchangers and electronic expansion valve. The range is composed by units equipped with four, six and eight compressors in multi-circuit configuration.

Page 187: Products Guide V01 - ParagonEfficient project management thanks to Climaveneta as unique project leader. Complete and specialized Organization Climaveneta qualifies itself for the

185

Note:

1 Evaporator water (in/out) = 12/7°C; Condenser air (in) = 35°C.

2 Condenser water (in/out) = 40/45°C; evaporator air (in) = 7°C - r.h. 87%.

3 Evaporator water (in/out) = 12/7°C; Recovery unit water (in/out) = 40/45°C

4 Sound power on the basis of measurements made in compliance with ISO 9614 and Eurovent 8/1 for Eurovent certified units; in compliance with ISO 3744 for non-certified units.

5 Average sound pressure level, at 10m distance, unit in a free field on a reflective surface; non-binding value obtained from the sound power level.

6 Unit in standard configuration/execution, without optional accessories

NECS-NR / CAModels 1314 1414 1614 1716 1816 2016 2116 2416 2418 2618 2818 3018 3218COOLING ONLYCooling capacity (1) kW 362 387 425 471 524 559 581 637 680 724 775 813 850Total power input (1) kW 122 128 145 157 173 185 192 217 230 244 256 272 289EER 2,96 3,03 2,94 3,01 3,04 3,03 3,03 2,94 2,95 2,96 3,03 2,99 2,94ESEER * * * * * * * * * * * * *HEATING ONLYHeating capacity (2) kW 394 420 462 507 546 603 630 693 729 788 840 882 924Total power input (2) kW 120 127 140 155 166 183 190 210 221 2394 253 266 280COP 3,30 3,31 3,30 3,28 3,29 3,30 3,32 3,30 3,29 3,29 3,32 3,31 3,30COOLING WITH TOTAL RECOVERYCooling capacity (3) kW 355 379 423 460 500 547 569 636 667 711 758 802 848Total power input (3) kW 107 113 126 139 150 163 170 189 200 213 227 240 252Heat recovery capacity (3) kW 394 485 542 590 640 700 728 814 854 912 971 1027 1085COMPRESSORSNo. Compressors/No. Circuits N. 4 / 2 4 / 2 4 / 2 6 / 3 6 / 3 6 / 3 6 / 3 6 / 3 8 / 4 8 / 4 8 / 4 8 / 4 8 / 4NOISE LEVELSSound power (4) dB(A) 97 97 97 97 98 98 98 99 99 99 100 100 100Sound pressure (5) dB(A) 65 65 65 64 65 65 65 66 66 66 67 67 67SIZEA (6) mm 5080 5080 5080 6255 7430 7430 7430 7430 9780 9780 9780 9780 9780B (6) mm 2260 2260 2260 2260 2260 2260 2260 2260 2260 2260 2260 2260 2260H (6) mm 2450 2450 2450 2450 2450 2450 2450 2450 2450 2450 2450 2450 2450Operating weight (6) kg 3850 3950 3980 5460 5740 5890 5970 6020 7350 7500 7700 7740 7770

Note:

1 Evaporator water (in/out) = 12/7°C; Condenser air (in) = 35°C.

2 Condenser water (in/out) = 40/45°C; evaporator air (in) = 7°C - r.h. 87%.

3 Evaporator water (in/out) = 12/7°C; Recovery unit water (in/out) = 40/45°C

4 Sound power on the basis of measurements made in compliance with ISO 9614 and Eurovent 8/1 for Eurovent certified units; in compliance with ISO 3744 for non-certified units.

5 Average sound pressure level, at 10m distance, unit in a free field on a reflective surface; non-binding value obtained from the sound power level.

6 Unit in standard configuration/execution, without optional accessories

NECS-NR / BModels 1314 1414 1614 1716 1816 2016 2116 2416 2418 2618 2818 3018 3218COOLING ONLYCooling capacity (1) kW 353 378 412 452 494 546 567 617 662 704 757 791 823Total power input (1) kW 125 131 150 163 176 189 196 225 235 250 262 281 300EER 2,81 2,89 2,75 2,77 2,82 2,89 2,89 2,74 2,82 2,81 2,89 2,82 2,74ESEER * * * * * * * * * * * * *HEATING ONLYHeating capacity (2) kW 380 408 447 485 528 587 612 670 704 761 817 855 893Total power input (2) kW 121 129 142 156 169 186 192 212 225 243 256 270 283COP 3,13 3,18 3,16 3,11 3,12 3,16 3,18 3,16 3,12 3,13 3,18 3,17 3,16COOLING WITH TOTAL RECOVERYCooling capacity (3) kW 355 379 423 460 500 547 569 636 667 711 758 802 848Total power input (3) kW 107 113 126 139 150 163 170 189 200 213 227 1027 252Heat recovery capacity (3) kW 455 485 542 590 640 700 728 814 854 912 971 240 1085COMPRESSORSNo. Compressors/No. Circuits N. 4 / 2 4 / 2 4 / 2 6 / 3 6 / 3 6 / 3 6 / 3 6 / 3 8 / 4 8 / 4 8 / 4 8 / 4 8 / 4NOISE LEVELSSound power (4) dB(A) 96 96 96 96 97 97 97 98 98 98 99 99 99Sound pressure (5) dB(A) 64 64 64 64 65 65 65 66 65 65 66 66 66SIZEA (6) mm 3905 3905 3905 4515 5690 5690 5690 5690 7430 7430 7430 7430 7430B (6) mm 2260 2260 2260 2260 2260 2260 2260 2260 2260 2260 2260 2260 2260H (6) mm 2450 2450 2450 2450 2450 2450 2450 2450 2450 2450 2450 2450 2450Operating weight (6) kg 3530 3620 3650 4850 5240 5370 5430 5480 6700 6830 7000 7030 7060

SCROLLAXIALSHELL & TUBESENERGY CLASS

Page 188: Products Guide V01 - ParagonEfficient project management thanks to Climaveneta as unique project leader. Complete and specialized Organization Climaveneta qualifies itself for the

186

Minimum clearance required1314-3218

Switchboard side mm 1500Switchboard opposite side mm 1500Plant exchagers opposite side mm 1500Plant exchagers side mm 2000

Note:

1 Evaporator water (in/out) = 12/7°C; Condenser air (in) = 35°C.

2 Condenser water (in/out) = 40/45°C; evaporator air (in) = 7°C - r.h. 87%.

3 Evaporator water (in/out) = 12/7°C; Recovery unit water (in/out) = 40/45°C

4 Sound power on the basis of measurements made in compliance with ISO 9614 and Eurovent 8/1 for Eurovent certified units; in compliance with ISO 3744 for non-certified units.

5 Average sound pressure level, at 10m distance, unit in a free field on a reflective surface; non-binding value obtained from the sound power level.

6 Unit in standard configuration/execution, without optional accessories

NECS-NR / SL-CAModels 1314 1414 1614 1716 1816 2016 2116 2416 2418 2618 2818 3018 3218COOLING ONLYCooling capacity (1) kW 332 357 398 429 500 512 536 596 616 663 715 754 795Total power input (1) kW 130 137 153 169 640 198 205 230 244 260 274 290 306EER 2,56 2,61 2,60 2,54 2,52 2,59 2,61 2,60 2,52 2,55 2,61 2,60 2,60ESEER * * * * * * * * * * * * *HEATING ONLYHeating capacity (2) kW 378 400 453 486 526 578 601 679 701 755 801 859 906Total power input (2) kW 116 124 138 151 163 178 186 207 217 233 248 262 276COP 3,25 3,22 3,29 3,22 3,23 3,25 3,23 3,28 3,23 3,24 3,23 3,28 3,28COOLING WITH TOTAL RECOVERYCooling capacity (3) kW 355 379 423 460 500 547 569 636 667 711 758 802 848Total power input (3) kW 107 113 126 139 150 163 170 189 200 213 227 1027 252Heat recovery capacity (3) kW 455 485 542 590 640 700 728 814 854 912 971 240 1085COMPRESSORSNo. Compressors/No. Circuits N. 4 / 2 4 / 2 4 / 2 6 / 3 6 / 3 6 / 3 6 / 3 6 / 3 8 / 4 8 / 4 8 / 4 8 / 4 8 / 4NOISE LEVELSSound power (4) dB(A) 88 88 88 89 89 90 90 91 91 91 92 92 92Sound pressure (5) dB(A) 56 56 56 57 57 57 57 58 58 58 59 59 59SIZEA (6) mm 4515 5080 5080 5690 5690 6865 7430 7430 7430 8605 9780 9780 9780B (6) mm 2260 2260 2260 2260 2260 2260 2260 2260 2260 2260 2260 2260 2260H (6) mm 2450 2450 2450 2450 2450 2450 2450 2450 2450 2450 2450 2450 2450Operating weight (6) kg 3760 3900 4050 5350 5490 5780 5890 6130 7020 7330 7600 7750 7910

AB

H

Page 189: Products Guide V01 - ParagonEfficient project management thanks to Climaveneta as unique project leader. Complete and specialized Organization Climaveneta qualifies itself for the

187

Page 190: Products Guide V01 - ParagonEfficient project management thanks to Climaveneta as unique project leader. Complete and specialized Organization Climaveneta qualifies itself for the

188

Main accessoriesCompressor power factor device

Hydronic group

VPF (Variable Primary Flow) kit: variable flow pumps with on board regulationSet-up for remote connectivity with ModBus/Echelon/Bacnet protocol cards

FeaturesUNIQUE PROPOSAL

Unique proposal: unit designed to satisfy, according to the mode of operation, requirements of cold water, hot water for heating or hot water for domestic use

EXTENSIVE RANGE OF OPERATION

Unit´s operation guaranteed with external air temperature down to -10°C during winter and up to 46°C during summer.

HOT WATER SUPPLY

Hot water supply up to 55°C. In winter mode the unit manages hot water production in the plant-side heat exchanger and in the reclaim one, with priority setted by customer, eventually at two different set-points

VERSION ´XL-CA-E´ AVAILABLE

Exclusive Premium version. Together for the first time, the lowest noise level on the market and the maximum efficiency in each operating mode.

VersionsCA Class A of efficiency

LN-CA Low Noise, Class A of efficiency

SL-CA Super Low noise version, Class A of efficiency

XL-CA eXtra Low noise version, Class A of efficiency

XL-CA-E eXtra Low noise, Class A enhanced

CommandsW3000SE LargeThe W3000SE Large controller offers advanced functions and algorithms. The keypad features an easy-to-use interface and a complete LCD display, allowing to consult and intervene on the unit by means of a multi-level menu, with selectable language setting. The regulation operates on both water circuits featuring the step-wise regulation referred to the return water temperature with proportional logic. This allows to satisfy simultaneously the different requests of both cooling and heating, according to the selected operation mode. The diagnostics includes a complete alarm management, with the “black-box” and alarm logging functions for enhanced analysis of the unit operation. For multiple units systems, the regulation of the resources, via optional proprietary devices, can be implemented. Energy metering, for both consumption and capacity, can also be developed. Supervision can be easily developed via proprietary devices or the integration in third party systems by means of the most common protocols as ModBus, Bacnet, Bacnet-over-IP, Echelon LonWorks. Compatibility with the remote keyboard managing up to 10 units. Availability of an internal real time clock for operation scheduling (4-day profiles with 10 hour belts). The defrost adopts a proprietary self-adaptive logic, which features the monitoring of numerous operational parameters. This allows to reduce the number and duration of the defrost cycles, with a benefit for the overall energy efficiency.

Hydronic - reversible

FOCS-NR 1062÷3222

Reversible unit, NRG line, total heat recovery, air source for outdoor installation

200 - 826 kWUnit DescriptionOutdoor heat pump unit for the production of chilled/hot water with semi-hermetic screw compressors optimized for R134a, axial-flow fans, external coil with copper tubes and aluminium fines, shell and tubes heat exchangers designed by Climaveneta and thermostatic expansion valve. Base and supporting structure and panels are galvanized epoxy powder coated steel with increased thickness. These units are designed for two-pipes systems and are able to produce hot or cold water and even hot water on an auxiliary circuit when needed for domestic utilities or post heating for air conditioning units.

Page 191: Products Guide V01 - ParagonEfficient project management thanks to Climaveneta as unique project leader. Complete and specialized Organization Climaveneta qualifies itself for the

189

Note:

1 Evaporator water (in/out) = 12/7°C; Condenser air (in) = 35°C.

2 Condenser water (in/out) = 40/45°C; evaporator air (in) = 7°C - r.h. 87%.

3 Evaporator water (in/out) = 12/7°C; Recovery unit water (in/out) = 40/45°C

4 Sound power on the basis of measurements made in compliance with ISO 9614 and Eurovent 8/1 for Eurovent certified units; in compliance with ISO 3744 for non-certified units.

5 Average sound pressure level, at 10m distance, unit in a free field on a reflective surface; non-binding value obtained from the sound power level.

6 Unit in standard configuration/execution, without optional accessories

FOCS-NR / LN-CAModels 1062 1162 1362 1562 1762 1962 2022 2222 2422 2622 2722 3222COOLING ONLYCooling capacity (1) kW 205 241 294 322 369 414 469 513 541 604 686 800Total power input (1) kW 70,8 84,3 103 109 130 144 163 168 177 206 226 274EER 2,90 2,86 2,85 2,95 2,84 2,88 2,88 3,05 3,06 2,93 3,04 2,92ESEER * * * * * * * * * * * *HEATING ONLYHeating capacity (2) kW 218 258 309 339 396 434 492 541 571 615 711 826Total power input (2) kW 67 80,7 92,2 101 122 131 149 159 169 178 207 240COP 3,25 3,20 3,35 3,36 3,25 3,31 3,30 3,40 3,38 3,46 3,43 3,44COOLING WITH TOTAL RECOVERYCooling capacity (3) kW 209 248 305 329 381 428 484 521 551 631 702 832Total power input (3) kW 60,6 71,9 87,1 92,5 111 122 137 145 153 170 193 224Heat recovery capacity (3) kW 269 320 392 422 493 549 621 666 704 801 895 1056COMPRESSORSNo. Compressors/No. Circuits N. 2 / 2 2 / 2 2 / 2 2 / 2 2 / 2 2 / 2 2 / 2 2 / 2 2 / 2 2 / 2 2 / 2 2 / 2NOISE LEVELSSound power (4) dB(A) 90 91 91 92 92 92 93 95 95 95 95 96Sound pressure (5) dB(A) 58 59 59 60 60 60 61 63 63 63 63 64SIZEA (6) mm 4610 4610 5610 5610 6610 6610 6300 7200 7200 7200 8400 9700B (6) mm 2220 2220 2220 2220 2220 2220 2260 2260 2260 2260 2260 2260H (6) mm 2150 2420 2430 2430 2430 2430 2350 2350 2350 2350 2350 2350Operating weight (6) kg * * * * * * * * * * * *

Note:

1 Evaporator water (in/out) = 12/7°C; Condenser air (in) = 35°C.

2 Condenser water (in/out) = 40/45°C; evaporator air (in) = 7°C - r.h. 87%.

3 Evaporator water (in/out) = 12/7°C; Recovery unit water (in/out) = 40/45°C

4 Sound power on the basis of measurements made in compliance with ISO 9614 and Eurovent 8/1 for Eurovent certified units; in compliance with ISO 3744 for non-certified units.

5 Average sound pressure level, at 10m distance, unit in a free field on a reflective surface; non-binding value obtained from the sound power level.

6 Unit in standard configuration/execution, without optional accessories

FOCS-NR / CAModels 1062 1162 1362 1562 1762 1962 2022 2222 2422 2622 2722 3222COOLING ONLYCooling capacity (1) kW 210 248 302 329 380 425 483 525 554 624 701 826Total power input (1) kW 72,1 84,5 102 109 129 144 156 167 176 201 222 264EER 2,91 2,93 2,96 3,02 2,95 2,95 3,10 3,14 3,15 3,10 3,16 3,13ESEER * * * * * * * * * * * *HEATING ONLYHeating capacity (2) kW 218 258 309 339 396 434 492 541 571 615 711 826Total power input (2) kW 67 80,7 92,2 101 122 131 149 159 169 178 207 240COP 3,25 3,20 3,35 3,36 3,25 3,31 3,30 3,40 3,38 3,46 3,43 3,44COOLING WITH TOTAL RECOVERYCooling capacity (3) kW 209 248 305 329 381 428 484 521 551 631 702 832Total power input (3) kW 60,6 71,9 87,1 92,5 111 122 137 145 153 170 193 224Heat recovery capacity (3) kW 269 320 392 422 493 549 621 666 704 801 895 1056COMPRESSORSNo. Compressors/No. Circuits N. 2 / 2 2 / 2 2 / 2 2 / 2 2 / 2 2 / 2 2 / 2 2 / 2 2 / 2 2 / 2 2 / 2 2 / 2NOISE LEVELSTotal power input kWSound power (4) dB(A) 97 97 97 98 99 99 99 101 101 101 101 102Sound pressure (5) dB(A) 65 65 65 66 67 67 67 69 69 69 69 70SIZEA (6) mm 4610 4610 5610 5610 6610 6610 6300 7200 7200 7200 8400 9700B (6) mm 2220 2220 2220 2220 2220 2220 2260 2260 2260 2260 2260 2260H (6) mm 2150 2420 2430 2430 2430 2430 2350 2350 2350 2350 2350 2350Operating weight (6) kg * * * * * * * * * * * *

r HFCR-134a

SCREWAXIALSHELL & TUBES

Page 192: Products Guide V01 - ParagonEfficient project management thanks to Climaveneta as unique project leader. Complete and specialized Organization Climaveneta qualifies itself for the

190

Note:

1 Evaporator water (in/out) = 12/7°C; Condenser air (in) = 35°C.

2 Condenser water (in/out) = 40/45°C; evaporator air (in) = 7°C - r.h. 87%.

3 Evaporator water (in/out) = 12/7°C; Recovery unit water (in/out) = 40/45°C

4 Sound power on the basis of measurements made in compliance with ISO 9614 and Eurovent 8/1 for Eurovent certified units; in compliance with ISO 3744 for non-certified units.

5 Average sound pressure level, at 10m distance, unit in a free field on a reflective surface; non-binding value obtained from the sound power level.

6 Unit in standard configuration/execution, without optional accessories

FOCS-NR / XL-CAModels 2022 2222 2422 2622 2722 3222COOLING ONLYCooling capacity (1) kW 455 501 528 584 667 772Total power input (1) kW 167 169 180 212 230 287EER 2,72 2,96 2,93 2,75 2,90 2,69ESEER * * * * * *HEATING ONLYHeating capacity (2) kW 486 536 564 607 703 816Total power input (2) kW 143 152 161 170 198 230COP 3,40 3,53 3,50 3,57 3,55 3,55COOLING WITH TOTAL RECOVERYCooling capacity (3) kW 484 521 551 631 702 832Total power input (3) kW 137 145 153 170 193 224Heat recovery capacity (3) kW 621 666 704 801 895 1056COMPRESSORSNo. Compressors/No. Circuits N. 2 / 2 2 / 2 2 / 2 2 / 2 2 / 2 2 / 2NOISE LEVELSSound power (4) dB(A) 85 87 87 87 87 88Sound pressure (5) dB(A) 53 55 55 55 55 56SIZEA (6) mm 6300 7200 7200 7200 8400 9700B (6) mm 2260 2260 2260 2260 2260 2260H (6) mm 2350 2350 2350 2350 2350 2350Operating weight (6) kg * * * * * *

Note:

1 Evaporator water (in/out) = 12/7°C; Condenser air (in) = 35°C.

2 Condenser water (in/out) = 40/45°C; evaporator air (in) = 7°C - r.h. 87%.

3 Evaporator water (in/out) = 12/7°C; Recovery unit water (in/out) = 40/45°C

4 Sound power on the basis of measurements made in compliance with ISO 9614 and Eurovent 8/1 for Eurovent certified units; in compliance with ISO 3744 for non-certified units.

5 Average sound pressure level, at 10m distance, unit in a free field on a reflective surface; non-binding value obtained from the sound power level.

6 Unit in standard configuration/execution, without optional accessories

FOCS-NR / SL-CAModels 1062 1162 1362 1562 1762 1962 2022 2222 2422 2622 2722 3222COOLING ONLYCooling capacity (1) kW 200 233 283 314 356 401 464 509 537 597 680 790Total power input (1) kW 72,7 87,2 109 113 137 149 166 170 180 210 229 281EER 2,75 2,67 2,60 2,78 2,60 2,69 2,80 2,99 2,98 2,84 2,97 2,81ESEER * * * * * * * * * * * *HEATING ONLYHeating capacity (2) kW 211 251 301 330 385 422 486 536 564 607 703 816Total power input (2) kW 64,8 78,4 89,9 98,4 119 127 147 157 167 176 205 238COP 3,26 3,20 3,35 3,35 3,24 3,32 3,31 3,41 3,38 3,45 3,43 3,43COOLING WITH TOTAL RECOVERYCooling capacity (3) kW 209 248 305 329 381 428 484 521 551 631 702 832Total power input (3) kW 60,6 71,9 87,1 92,5 111 122 137 145 153 170 193 224Heat recovery capacity (3) kW 269 320 392 422 493 549 621 666 704 801 895 1056COMPRESSORSNo. Compressors/No. Circuits N. 2 / 2 2 / 2 2 / 2 2 / 2 2 / 2 2 / 2 2 / 2 2 / 2 2 / 2 2 / 2 2 / 2 2 / 2NOISE LEVELSSound power (4) dB(A) 86 87 87 88 88 88 89 91 91 91 91 92Sound pressure (5) dB(A) 54 55 55 56 56 56 57 59 59 59 59 60SIZEA (6) mm 4610 4610 5610 5610 6610 6610 6300 7200 7200 7200 8400 9700B (6) mm 2220 2220 2220 2220 2220 2220 2260 2260 2260 2260 2260 2260H (6) mm 2150 2420 2430 2430 2430 2430 2350 2350 2350 2350 2350 2350Operating weight (6) kg * * * * * * * * * * * *

Page 193: Products Guide V01 - ParagonEfficient project management thanks to Climaveneta as unique project leader. Complete and specialized Organization Climaveneta qualifies itself for the

191

Minimum clearance required1062-1762 2022-2622

Switchboard side mm 1100 1800Switchboard opposite side mm 1100 1500Condensation coil side mm 2000 2000

Note:

1 Evaporator water (in/out) = 12/7°C; Condenser air (in) = 35°C.

2 Condenser water (in/out) = 40/45°C; evaporator air (in) = 7°C - r.h. 87%.

3 Evaporator water (in/out) = 12/7°C; Recovery unit water (in/out) = 40/45°C

4 Sound power on the basis of measurements made in compliance with ISO 9614 and Eurovent 8/1 for Eurovent certified units; in compliance with ISO 3744 for non-certified units.

5 Average sound pressure level, at 10m distance, unit in a free field on a reflective surface; non-binding value obtained from the sound power level.

6 Unit in standard configuration/execution, without optional accessories

FOCS-NR / XL-CA-EModels 1062 1162 1362 1562 1762 2022 2222 2422 2622COOLING ONLYCooling capacity (1) kW 204 247 293 319 366 473 510 541 611Total power input (1) kW 66,6 76,6 99,4 105 127 153 163 169 193EER 3,06 3,22 2,95 3,04 2,88 3,09 3,13 3,20 3,17ESEER * * * * * * * * *HEATING ONLYHeating capacity (2) kW 218 267 308 340 393 513 552 588 644Total power input (2) kW 62,4 77,6 88,3 95,2 116 145 154 164 176COP 3,49 3,44 3,49 3,57 3,39 3,54 3,58 3,59 3,66COOLING WITH TOTAL RECOVERYCooling capacity (3) kW 209 248 305 329 381 484 521 551 631Total power input (3) kW 60,6 71,9 87,1 92,5 111 137 145 153 170Heat recovery capacity (3) kW 269 320 392 422 493 621 666 704 801COMPRESSORSNo. Compressors/No. Circuits N. 2 / 2 2 / 2 2 / 2 2 / 2 2 / 2 2 / 2 2 / 2 2 / 2 2 / 2NOISE LEVELSSound power (4) dB(A) 85 86 86 87 87 86 88 88 88Sound pressure (5) dB(A) 53 54 54 55 55 54 56 56 56SIZEA (6) mm 4610 5610 5610 6610 6610 8400 9300 9300 9300B (6) mm 2220 2220 2220 2220 2220 2260 2260 2260 2260H (6) mm 2420 2430 2430 2430 2430 2350 2350 2350 2350Operating weight (6) kg * * * * * * * * *

Page 194: Products Guide V01 - ParagonEfficient project management thanks to Climaveneta as unique project leader. Complete and specialized Organization Climaveneta qualifies itself for the

192

Main accessoriesRemote keyboard (distance to 200m and to 500m)

Water connections directed upwards (for 2 compressors units only)

Acoustical enclosure to reduce the noise emissions.

Set-up for remote connectivity with ModBus, Echelon LonTalk, Bacnet protocol board

FeaturesREFRIGERANT GAS R410A

The use of R410A has resulted in units offering better energy efficiency in full respect for the environment (ODP = 0)

INTEGRATED CONDENSATION´S CONTROL

A 2 way valve is supplied as standard for the condensing pressure control. For all the applications in which a constant waterflow through the condenser is needed, a 3-way valve option is also available under request.

ENERGY SAVING

Energy saving guaranteed by the advanced operations logic. The best operation mode is set completely automatically and independently by the units controller, in order to minimize the absorbed energy whatever the cooling and/or heating demand might be

HOT WATER SUPPLY

Production of domestic hot water up to 55°C in both summer and winter operating conditions, offering maximum versatility with respect to different plant engineering solutions.

Versions- base version

CommandsW3000 largeThe controller W3000 large offers the latest control and functions developed directly by Climaveneta on the basis of their experience gained over the years with these particular units and the related plant engineering. The keypad is generously sized with full operating status display. The controls and detailed LCD make access to machine settings easy and safe. Temperature regulation managed on the two water circuits, with a proportional logic referred to the return water temperatures. This allows to satisfy simultaneously the different heating- and cooling requests, with no need of mode changeover. The diagnostics includes full management of alarms with black-box functions and alarm record for better analysis of unit performance. Supervision is easy through Climaveneta devices or with various options for interfacing to ModBus, Bacnet, Echelon LonTalk protocols. Compatibility with remote keyboard (management up to 10 units). Clock available with programming of operation (standard 4 days and 10 time bands). Exclusive self-adaptive defrost logic, monitoring multiple operational- and ambient parameters, which allows to reduce the number and duration of the defrost cycles, with a benefit for the overall energy efficiency.

Hydronic - reversible

NECS-WNR 0152÷1604

Reversible unit, NRG line, total heat recovery, water source

5,7 - 491 kWUnit DescriptionWater source reversible unit with total heat recovery for the simultaneous production of chilled/hot water with hermetic rotary Scroll compressors, with R410A, plate heat exchangers and thermostatic expansion valve. The range is composed by units equipped with two and four compressors, all with two refrigerant circuits.

Page 195: Products Guide V01 - ParagonEfficient project management thanks to Climaveneta as unique project leader. Complete and specialized Organization Climaveneta qualifies itself for the

193

Minimum clearance required0152-0612 0604-1604

Switchboard side mm 800 1000Switchboard opposite side mm 800 1000Unit’s side mm 800 800

Note:

1 Evaporator water (in/out) = 12/7°C; condenser water (in/out) = 14/30°C

2 Condenser water (in/out) = 40/45°C; evaporator water (in/out) = 14/7°C

3 Evaporator water (in/out) = 12/7°C; Recovery unit water (in/out) = 40/45°C

4 Sound power on the basis of measurements made in compliance with ISO 9614 and Eurovent 8/1 for Eurovent certified units; in compliance with ISO 3744 for non-certified units.

5 Average sound pressure level, at 10m distance, unit in a free field on a reflective surface; non-binding value obtained from the sound power level.

6 Unit in standard configuration/execution, without optional accessories

Models 0604 0704 0804 0904 1004 1104 1204 1404 1604COOLING ONLYCooling capacity (1) kW 194 225 255 285 317 365 413 468 522Total power input (1) kW 34,8 40 45,3 50,8 56,3 64,8 73 84,1 95,1EER 5,58 5,63 5,62 5,61 5,63 5,63 5,66 5,56 5,49ESEER * * * * * * * * *HEATING ONLYHeating capacity (2) kW 208 240 270 303 338 388 440 498 557Total power input (2) kW 47,7 54,7 61,8 69,2 76,8 88,4 99,6 113 126COP 4,36 4,38 4,37 4,38 4,40 4,39 4,41 4,41 4,42COOLING WITH TOTAL RECOVERYCooling capacity (3) kW 163 188 212 238 266 305 346 392 438Total power input (3) kW 47,7 54,7 61,8 69,2 76,8 88,4 99,6 113 126Heat recovery capacity (3) kW 208 240 270 303 338 388 440 498 557COMPRESSORSNo. Compressors/No. Circuits N. 4 / 2 4 / 2 4 / 2 4 / 2 4 / 2 4 / 2 4 / 2 4 / 2 4 / 2NOISE LEVELSTotal power input kWSound power (4) dB(A) 86 87 88 89 90 91 91 91 91Sound pressure (5) dB(A) 54 55 56 57 58 59 59 59 59SIZEA (6) mm 2520 2520 2520 2520 2520 2520 2520 2520 2520B (6) mm 880 880 880 880 880 880 880 880 880H (6) mm 1810 1810 1810 1810 1810 1810 1810 1810 1810Operating weight (6) kg 975 1165 1365 1445 1610 1710 1810 1895 2000

NECS-WNR / -Models 0152 0182 0202 0252 0262 0302 0412 0512 0612COOLING ONLYCooling capacity (1) kW 48,6 55,8 65 73,8 83,2 97,5 127 159 206Total power input (1) kW 8,70 9,80 11,3 13,2 14,7 17,4 22,7 28,1 36,5EER 5,59 5,69 5,75 5,59 5,66 5,60 5,59 5,64 5,63ESEER * * * * * * * * *HEATING ONLYHeating capacity (2) kW 52,1 59,7 69,3 79 88,9 104 135 169 219Total power input (2) kW 12,4 13,8 16,2 18,5 20,4 23,9 31 38,4 49,9COP 4,20 4,33 4,28 4,28 4,36 4,37 435 4,40 4,38COOLING WITH TOTAL RECOVERYCooling capacity (3) kW 40,4 46,7 54,1 61,7 67,9 82 106 133 172Total power input (3) kW 12,4 13,8 16,2 18,5 20,4 23,9 31 38,4 49,9Heat recovery capacity (3) kW 52,1 59,7 69,3 79 88,9 104 135 169 219COMPRESSORSNo. Compressors/No. Circuits N. 2 / 2 2 / 2 2 / 2 2 / 2 2 / 2 2 / 2 2 / 2 2 / 2 2 / 2NOISE LEVELSTotal power input kWSound power (4) dB(A) 73 74 74 74 75 76 77 78 79Sound pressure (5) dB(A) 42 43 43 43 44 45 46 47 48SIZEA (6) mm 1222 1222 1222 1222 1222 1222 1222 1222 1222B (6) mm 893 893 893 893 893 893 893 893 893H (6) mm 1496 1496 1496 1496 1496 1496 1496 1496 1496Operating weight (6) kg 450 470 490 505 525 550 745 825 910

r HFCR-410A

SCROLLPLATES

H

BA

H

B A

Page 196: Products Guide V01 - ParagonEfficient project management thanks to Climaveneta as unique project leader. Complete and specialized Organization Climaveneta qualifies itself for the

194

Main accessoriesIntegral acoustical enclosure (type base or plus)

Several devices for condensation´s control

Electronic expansion valve

Set-up for remote connectivity with ModBus/Echelon/Bacnet protocol cards

FeaturesUNIQUE PROPOSAL

Unique proposal: unit designed to satisfy, according to the mode of operation, requirements of cold water, hot water for heating or hot water for domestic use

ENERGY SAVING

Free domestic hot water during summer season.

HOT WATER SUPPLY

Hot water supply up to 55°C. In winter mode the unit manages hot water production in the plant-side heat exchanger and in the reclaim one, with priority setted by customer, eventually at two different set-points

INTEGRATED CONDENSATION´S CONTROL

A 2 way valve is supplied as standard for the condensing pressure control. For all the applications in which a constant waterflow through the condenser is needed, a 3-way valve option is also available under request.

Versions- base version

CommandsW3000SE LargeThe W3000SE Large controller offers advanced functions and algorithms. The keypad features an easy-to-use interface and a complete LCD display, allowing to consult and intervene on the unit by means of a multi-level menu, with selectable language setting. The regulation operates on both water circuits featuring the step-wise regulation referred to the return water temperature with proportional logic. This allows to satisfy simultaneously the different requests of both cooling and heating, according to the selected operation mode. The diagnostics includes a complete alarm management, with the “black-box” and alarm logging functions for enhanced analysis of the unit operation. For multiple units systems, the regulation of the resources, via optional proprietary devices, can be implemented. Energy metering, for both consumption and capacity, can also be developed. Supervision can be easily developed via proprietary devices or the integration in third party systems by means of the most common protocols as ModBus, Bacnet, Bacnet-over-IP, Echelon LonWorks. Compatibility with the remote keyboard managing up to 10 units. Availability of an internal real time clock for operation scheduling (4-day profiles with 10 hour belts).

Hydronic - reversible

FOCS-WNR 0802÷3202

Reversible unit, NRG line, total heat recovery, water source

194 - 891 kWUnit DescriptionHeat pump unit for indoor installation, designed for 2-pipes plants application for summer/winter air conditioning. Unit complete with a section for the condensation heat reclaim: a dedicated heat exchanger produces on request hot water for secondary uses (domestic hot water, air treatment in AHU, ...). Semi-hermetic screw compressor, R134a, shell and tube heat exchangers both, plant-side (primary, working as an evaporator or condenser as a function of unit´s commutation, and secondary, working only as a condenser) and source-side. Frame in polyester-painted galvanized steel.

Page 197: Products Guide V01 - ParagonEfficient project management thanks to Climaveneta as unique project leader. Complete and specialized Organization Climaveneta qualifies itself for the

195

Minimum clearance required0802-3202

Switchboard side mm 800Switchboard opposite side mm 500Condensation coil side mm 500

Note:

1 Evaporator water (in/out) = 12/7°C; condenser water (in/out) = 14/30°C

2 Condenser water (in/out) = 40/45°C; evaporator water (in/out) = 14/7°C

3 Evaporator water (in/out) = 12/7°C; Recovery unit water (in/out) = 40/45°C

4 Sound power on the basis of measurements made in compliance with ISO 9614 and Eurovent 8/1 for Eurovent certified units; in compliance with ISO 3744 for non-certified units.

5 Average sound pressure level, at 1 m distance, unit in a free field on a reflective surface; non-binding value obtained from the sound power level.

6 Unit in standard configuration/execution, without optional accessories

FOCS-WNR / -Models 0802 1002 1102 1302 1502 1702 1902 2152 2502 2602 2702 3202 0802COOLING ONLYCooling capacity (1) kW 194 240 275 326 373 435 479 554 648 703 781 891 194Total power input (1) kW 34,3 43,2 48,5 57,2 66,1 76,5 85,7 94,5 111 121 135 153 34,3EER 5,66 5,56 5,66 5,69 5,64 5,68 5,58 5,87 5,83 5,83 5,80 5,81 5,66ESEER * * * * * * * * * * * * *HEATING ONLYHeating capacity (2) kW 205 255 291 344 393 459 514 589 686 738 831 941 205Total power input (2) kW 45,7 57,0 65,9 76,3 86,9 103 117 128 149 158 180 205 45,7COP 4,49 4,47 4,42 4,51 4,52 4,44 4,40 4,59 4,62 4,68 4,62 4,59 4,49COOLING WITH TOTAL RECOVERYCooling capacity (3) kW 162 201 229 272 311 362 404 468 547 589 662 748 162Total power input (3) kW 45,7 57,0 65,9 76,3 86,9 103 117 128 149 158 180 205 45,7Heat recovery capacity (3) kW 205 255 291 344 393 459 514 589 686 738 831 941 205COMPRESSORSNo. Compressors/No. Circuits N. 2 / 2 2 / 2 2 / 2 2 / 2 2 / 2 2 / 2 2 / 2 2 / 2 2 / 2 2 / 2 2 / 2 2 / 2 2 / 2NOISE LEVELSTotal power input kWSound power (4) dB(A) 94 95 97 97 97 97 97 98 99 99 99 99 94Sound pressure (5) dB(A) 76 77 79 79 79 79 78 79 80 80 80 80 76SIZEA (6) mm 3680 3680 3680 3680 3680 3680 3800 3800 3800 5000 5000 5000 3680B (6) mm 1170 1170 1170 1170 1170 1170 1490 1490 1490 1490 1490 1490 1170H (6) mm 1950 1950 1950 1950 1950 1950 1950 1950 1950 1950 1950 1950 1950Operating weight (6) kg * * * * * * * * * * * * *

r HFCR-134a

SCREWSHELL & TUBES

Page 198: Products Guide V01 - ParagonEfficient project management thanks to Climaveneta as unique project leader. Complete and specialized Organization Climaveneta qualifies itself for the

196

Page 199: Products Guide V01 - ParagonEfficient project management thanks to Climaveneta as unique project leader. Complete and specialized Organization Climaveneta qualifies itself for the

197

Page 200: Products Guide V01 - ParagonEfficient project management thanks to Climaveneta as unique project leader. Complete and specialized Organization Climaveneta qualifies itself for the

198

Main accessoriesSet-up for remote connectivity with ModBus/Echelon/Bacnet protocol cards

Remote keyboard (distance to 200m and to 500m)

Soft starters

Rubber anti-vibration mounting kit

FeaturesUNIQUE PROPOSAL

Unit designed to satisfy the cold and the hot side requirements simultaneously, for 4-pipe systems without any particular operation mode setting

TOTAL VERSATILITY

Climaveneta is the only company to offer all-in-one units with Scroll compressors in 3 versions designed to satisfy all service system and application requirements

CUTTING-EDGE ELECTRONICS

The Energy Raiser units are fitted with an evolved electronic unit that allows fully automatic management of the best type of operation to meet the load requirementsVENTILATION CONTROL FOR LOW-TEMPERATURE OPERATIONThe standard units come fitted with pressure-operated control of ventilation, which allows the unit to produce cold water with an external air temperature down to -10°C

INTEGRATED HYDRONIC MODULE

The built-in hydronic module already contains the main water circuit components; it is available with single or twin in-line pump, for achieving both low or high head, available for both plant and recovery circuits (up to 4 pumps).

VersionsB base version

LN low noise version

SL super-low noise version

CommandsW3000SE LargeThe W3000SE Large controller offers advanced functions and algorithms. The keypad features an easy-to-use interface and a complete LCD display, allowing to consult and intervene on the unit by means of a multi-level menu, with selectable language setting. The regulation operates on both water circuits featuring the step-wise regulation referred to the return water temperature with proportional logic. This allows to satisfy simultaneously the different requests of both cooling and heating, with no need of mode setting. The diagnostics includes a complete alarm management, with the “black-box” and alarm logging functions for enhanced analysis of the unit operation. For multiple units systems, the regulation of the resources, via optional proprietary devices, can be implemented. Energy metering, for both consumption and capacity, can also be developed. Supervision can be easily developed via proprietary devices or the integration in third party systems by means of the most common protocols as ModBus, Bacnet, Bacnet-over-IP, Echelon LonWorks. Compatibility with the remote keyboard managing up to 10 units. Availability of an internal real time clock for operation scheduling (4-day profiles with 10 hour belts). The defrost adopts a proprietary self-adaptive logic, which features the monitoring of numerous operational parameters. This allows to reduce the number and duration of the defrost cycles, with a benefit for the overall energy efficiency.

INTEGRA

NECS-Q 0152÷1204

INTEGRA unit for 4-pipe systems, air source for outdoor installation

36 - 311 kWUnit DescriptionMulti-purpose outdoor unit for use in 4-pipe systems for the simultaneous production of chilled and hot water by means of two independent hydronic circuits. These units are able to satisfy the demand for hot and cold water simultaneously through a system that does not require seasonal switching and is therefore a valid alternative to traditional plants with chiller and boiler. This unit is equipped with hermetic rotary Scroll compressors, with R410A, axial fans, braze-welded plate-type exchanger and thermal expansion valve. External panels in Peraluman and base in galvanised sheet steel with paint finish. The range includes two-compressor and four-compressor versions, both with two independent refrigerant circuits.

Page 201: Products Guide V01 - ParagonEfficient project management thanks to Climaveneta as unique project leader. Complete and specialized Organization Climaveneta qualifies itself for the

199

Note:

1 Evaporator water (in/out) = 12/7°C; Condenser air (in) = 35°C.

2 Condenser water (in/out) = 40/45°C; evaporator air (in) = 7°C - r.h. 87%.

3 Evaporator water (in/out) = 12/7°C; Recovery unit water (in/out) = 40/45°C

4 TER := Total Efficiency Ratio = (Cooling capacity + Heating capacity) / (Total power input)

5 Sound power on the basis of measurements made in compliance with ISO 9614 and Eurovent 8/1 for Eurovent certified units; in compliance with ISO 3744 for non-certified units.

6 Average sound pressure level, at 10m distance, unit in a free field on a reflective surface; non-binding value obtained from the sound power level.

Models 0612 0604 0704 0804 0904 1004 1104 1204COOLING ONLYCooling capacity (1) kW 151 150 166 189 211 240 277 311Total power input (1) kW 56,6 58,9 69 75,8 85,2 95,6 107 121EER 2,66 2,54 2,41 2,49 2,48 2,51 2,58 2,58HEATING ONLYHeating capacity (2) kW 173 167 185 209 234 267 306 344Total power input (2) kW 52,1 58 64,9 72,1 79,8 92 104 116COP 3,31 2,88 2,86 2,90 2,93 2,90 2,94 2,96COOLING WITH TOTAL RECOVERYCooling capacity (3) kW 160 151 173 194 220 246 281 317Heat recovery capacity (3) kW 208 198 226 255 288 321 368 415Total power input (3) kW 51,3 49,8 57,1 64,5 72,1 79,8 92,8 105TER (4) - 7,17 7,01 6,99 6,96 7,05 7,11 6,99 6,97COMPRESSORSNo. Compressors/No. Circuits N. 2 / 2 4 / 2 4 / 2 4 / 2 4 / 2 4 / 2 4 / 2 4 / 2NOISE LEVELSSound power (5) dB(A) 87 92 92 92 93 94 95 95Sound pressure (6) dB(A) 55 60 60 60 61 62 63 63SIZEA mm 3570 3110 3110 3110 4110 4110 4110 4110B mm 1300 2220 2220 2220 2220 2220 2220 2220H mm 1620 2150 2150 2150 2150 2150 2150 2150Operating weight kg 1290 1600 1840 2120 2320 2480 2680 2860

NECS-Q / BModels 0152 0182 0202 0252 0262 0302 0412 0512COOLING ONLYCooling capacity (1) kW 36,6 43,2 48,5 55,8 61,2 73,3 94,8 120Total power input (1) kW 13,3 14,5 17,9 19,9 22,8 26,2 33,6 41,7EER 2,76 2,99 2,71 2,80 2,68 2,80 2,82 2,88HEATING ONLYHeating capacity (2) kW 41,1 48,9 55,3 62,5 68,1 83,1 107 136Total power input (2) kW 13,3 14,7 17,2 19,7 21,4 24,9 32,1 40COP 3,10 3,33 3,22 3,17 3,18 3,34 3,34 3,40COOLING WITH TOTAL RECOVERYCooling capacity (3) kW 37,2 43,6 50,6 57,2 64,1 76,3 97,7 124Heat recovery capacity (3) kW 49,2 56,9 66,2 75 83,8 99,3 128 161Total power input (3) kW 12,8 14,2 16,6 18,9 21 24,5 31,9 39,6TER (4) - 6,75 7,08 7,04 6,99 7,04 7,17 7,08 7,20COMPRESSORSNo. Compressors/No. Circuits N. 2 / 2 2 / 2 2 / 2 2 / 2 2 / 2 2 / 2 2 / 2 2 / 2NOISE LEVELSSound power (5) dB(A) 84 84 84 84 84 85 86 87Sound pressure (6) dB(A) 52 52 52 52 52 53 54 55SIZEA mm 2020 2020 2020 2520 2520 2520 3070 3570B mm 1300 1300 1300 1300 1300 1300 1300 1300H mm 1620 1620 1620 1620 1620 1620 1620 1620Operating weight kg 570 590 600 660 670 720 1030 1180

SYSTEM

4 PIPE

r HFCR-410A

SCROLLAXIALPLATES

Page 202: Products Guide V01 - ParagonEfficient project management thanks to Climaveneta as unique project leader. Complete and specialized Organization Climaveneta qualifies itself for the

200

Note:

1 Evaporator water (in/out) = 12/7°C; Condenser air (in) = 35°C.

2 Condenser water (in/out) = 40/45°C; evaporator air (in) = 7°C - r.h. 87%.

3 Evaporator water (in/out) = 12/7°C; Recovery unit water (in/out) = 40/45°C

4 TER := Total Efficiency Ratio = (Cooling capacity + Heating capacity) / (Total power input)

5 Sound power on the basis of measurements made in compliance with ISO 9614 and Eurovent 8/1 for Eurovent certified units; in compliance with ISO 3744 for non-certified units.

6 Average sound pressure level, at 10m distance, unit in a free field on a reflective surface; non-binding value obtained from the sound power level.

NECS-Q / LNModels 0604 0704 0804 0904 1004 1104 1204COOLING ONLYCooling capacity (1) kW 143 157 177 199 227 261 291Total power input (1) kW 58,8 70,2 78,4 87,8 96,5 110 125EER 2,43 2,24 2,26 2,27 2,36 2,37 2,32HEATING ONLYHeating capacity (2) kW 160 176 198 225 254 290 324Total power input (2) kW 54 60,8 67,9 75,7 85,8 97,9 110COP 2,95 2,89 2,92 2,98 2,95 2,96 2,94COOLING WITH TOTAL RECOVERYCooling capacity (3) kW 151 173 194 220 246 281 317Heat recovery capacity (3) kW 198 226 255 288 321 368 415Total power input (3) kW 49,8 57,1 64,5 72,1 79,8 92,8 105TER (4) - 7,01 6,99 6,96 7,05 7,11 6,99 6,97COMPRESSORSNo. Compressors/No. Circuits N. 4 / 2 4 / 2 4 / 2 4 / 2 4 / 2 4 / 2 4 / 2NOISE LEVELSSound power (5) dB(A) 86 86 86 87 88 89 89Sound pressure (6) dB(A) 54 54 54 55 56 57 57SIZEA mm 3110 3110 3110 4110 4110 4110 4110B mm 2220 2220 2220 2220 2220 2220 2220H mm 2150 2150 2150 2150 2150 2150 2150Operating weight kg 1600 1840 2120 2320 2480 2680 2860

Page 203: Products Guide V01 - ParagonEfficient project management thanks to Climaveneta as unique project leader. Complete and specialized Organization Climaveneta qualifies itself for the

201

Minimum clearance required0152-1204

Switchboard side mm 1100Switchboard opposite side mm 1100Condensation coil side mm 2000

Note:

1 Evaporator water (in/out) = 12/7°C; Condenser air (in) = 35°C.

2 Condenser water (in/out) = 40/45°C; evaporator air (in) = 7°C - r.h. 87%.

3 Evaporator water (in/out) = 12/7°C; Recovery unit water (in/out) = 40/45°C

4 TER := Total Efficiency Ratio = (Cooling capacity + Heating capacity) / (Total power input)

5 Sound power on the basis of measurements made in compliance with ISO 9614 and Eurovent 8/1 for Eurovent certified units; in compliance with ISO 3744 for non-certified units.

6 Average sound pressure level, at 10m distance, unit in a free field on a reflective surface; non-binding value obtained from the sound power level.

Models 0612 0604 0704 0804 0904 1004 1104 1204COOLING ONLYCooling capacity (1) kW 143 142 160 183 201 225 261 294Total power input (1) kW 60,4 58 67,4 75,5 87,3 95,5 108 123EER 2,37 2,45 2,37 2,43 2,30 2,36 2,41 2,38HEATING ONLYHeating capacity (2) kW 169 159 178 205 226 253 295 330Total power input (2) kW 52 52,6 59,5 68,7 76,1 83,8 96,1 110COP 3,26 3,02 2,99 2,99 2,98 3,02 3,07 3COOLING WITH TOTAL RECOVERYCooling capacity (3) kW 160 151 173 194 220 246 281 317Heat recovery capacity (3) kW 208 198 226 255 288 321 368 415Total power input (3) kW 51,3 49,8 57,1 64,5 72,1 79,8 92,8 105TER (4) - 7,17 7,01 6,99 6,96 7,05 7,11 6,99 6,97COMPRESSORSNo. Compressors/No. Circuits N. 2 / 2 4 / 2 4 / 2 4 / 2 4 / 2 4 / 2 4 / 2 4 / 2NOISE LEVELSSound power (5) dB(A) 83 82 82 83 83 83 85 86Sound pressure (6) dB(A) 51 50 50 51 51 51 53 54SIZEA mm 3570 3110 3110 4110 4110 4110 5110 5110B mm 1300 2220 2220 2220 2220 2220 2220 2220H mm 1620 2150 2150 2150 2150 2150 2150 2150Operating weight kg 1290 1700 1960 2350 2420 2590 2950 3100

NECS-Q / SLModels 0152 0182 0202 0252 0262 0302 0412 0512COOLING ONLYCooling capacity (1) kW 33,3 39,6 47 50,9 58,3 69,1 93,9 119Total power input (1) kW 15 16,5 18,7 22,4 24,4 28,4 34,1 42,3EER 2,21 2,39 2,52 2,28 2,39 2,43 2,75 2,81HEATING ONLYHeating capacity (2) kW 40 47,4 55,1 60,9 70,5 80,9 109 138Total power input (2) kW 13,1 14,6 17,2 19,7 21,5 24,8 32,2 40,1COP 3,04 3,24 3,21 3,10 3,28 3,26 3,38 3,43COOLING WITH TOTAL RECOVERYCooling capacity (3) kW 37,2 43,6 50,6 57,2 64,1 76,3 97,7 124Heat recovery capacity (3) kW 49,2 56,9 66,2 74,9 83,8 99,3 128 161Total power input (3) kW 12,8 14,2 16,6 18,9 21 24,5 31,9 39,6TER (4) - 6,75 7,08 7,04 6,99 7,04 7,17 7,08 7,20COMPRESSORSNo. Compressors/No. Circuits N. 2 / 2 2 / 2 2 / 2 2 / 2 2 / 2 2 / 2 2 / 2 2 / 2NOISE LEVELSSound power (5) dB(A) 78 78 79 79 79 80 82 83Sound pressure (6) dB(A) 46 46 47 47 47 48 50 51SIZEA mm 2020 2020 2520 2520 2520 3070 3070 3570B mm 130 1300 1300 1300 1300 1300 1300 1300H mm 1620 1620 1620 1620 1620 1620 1620 1620Operating weight kg 570 590 660 660 700 780 1070 1230

A

B

H

AB

H

Page 204: Products Guide V01 - ParagonEfficient project management thanks to Climaveneta as unique project leader. Complete and specialized Organization Climaveneta qualifies itself for the

202

Main accessoriesRemote keyboard (distance to 200m and to 500m)

Soft starters

Set-up for remote connectivity with ModBus, Echelon LonTalk, Bacnet protocol boardLT kit for extending the operating limits in heat pump mode down to -10°C (/SL-CA versions) and -12°C (/CA versions)

FeaturesREFRIGERANT GAS R410A

The use of R410A has resulted in units offering better energy efficiency in full respect for the environment (ODP = 0)

UNIQUE PROPOSAL

Unit designed to satisfy the cold and the hot side requirements simultaneously, for 4-pipe systems without any particular operation mode setting

ENERGY SAVING

Energy saving guaranteed by the advanced operations logic. The best operation mode is set completely automatically and independently by the units controller, in order to minimize the absorbed energy whatever the cooling and/or heating demand might be

CLASS A EFFICIENCY

The full range is also available with the Class A efficiency rating. NECS-Q/CA and NECS-Q/SL-CA guaranty premium levels of efficiency thanks to the generous sizing of the refrigerant-exchange surface areas and to an accurate control of the fans, available on both standard and low-noise versions.

INTEGRATED HYDRONIC MODULE

The built-in hydronic module already contains the main water circuit components; it is available with single or twin in-line pump, for achieving low or high head, available for both hot and cold water distribution systems (up to 4 pumps).

VersionsB base version

CA Class A of efficiency

SL-CA Super Low noise version, Class A of efficiency

CommandsW3000SE LargeThe W3000SE Large controller offers advanced functions and algorithms. The keypad features an easy-to-use interface and a complete LCD display, allowing to consult and intervene on the unit by means of a multi-level menu, with selectable language setting. The regulation operates on both water circuits featuring the step-wise regulation referred to the return water temperature with proportional logic. This allows to satisfy simultaneously the different requests of both cooling and heating, with no need of mode setting. The diagnostics includes a complete alarm management, with the “black-box” and alarm logging functions for enhanced analysis of the unit operation. For multiple units systems, the regulation of the resources, via optional proprietary devices, can be implemented. Energy metering, for both consumption and capacity, can also be developed. Supervision can be easily developed via proprietary devices or the integration in third party systems by means of the most common protocols as ModBus, Bacnet, Bacnet-over-IP, Echelon LonWorks. Compatibility with the remote keyboard managing up to 10 units. Availability of an internal real time clock for operation scheduling (4-day profiles with 10 hour belts). The defrost adopts a proprietary self-adaptive logic, which features the monitoring of numerous operational parameters. This allows to reduce the number and duration of the defrost cycles, with a benefit for the overall energy efficiency.

INTEGRA

NECS-Q 1314÷3218

INTEGRA unit for 4-pipe systems, air source for outdoor installation

353 - 823 kWUnit DescriptionMulti-purpose outdoor unit for use in 4-pipe systems for the simultaneous production of chilled and hot water by means of two independent hydronic circuits. These units are able to satisfy the demand for hot and cold water simultaneously through a system that does not require seasonal switching and is therefore a valid alternative to traditional plants with chiller and boiler. This unit is equipped with hermetic rotary Scroll compressors, with R410A, axial fans, shell and tube heat exchangers and electronic expansion valve. The range is composed by units equipped with four, six and eight compressors in multi-circuit configuration.

Page 205: Products Guide V01 - ParagonEfficient project management thanks to Climaveneta as unique project leader. Complete and specialized Organization Climaveneta qualifies itself for the

203

Note:

1 Evaporator water (in/out) = 12/7°C; Condenser air (in) = 35°C.

2 Condenser water (in/out) = 40/45°C; evaporator air (in) = 7°C - r.h. 87%.

3 Evaporator water (in/out) = 12/7°C; Recovery unit water (in/out) = 40/45°C

4 TER := Total Efficiency Ratio = (Cooling capacity + Heating capacity) / (Total power input)

5 Sound power on the basis of measurements made in compliance with ISO 9614 and Eurovent 8/1 for Eurovent certified units; in compliance with ISO 3744 for non-certified units.

6 Average sound pressure level, at 10m distance, unit in a free field on a reflective surface; non-binding value obtained from the sound power level.

NECS-Q / CAModels 1314 1414 1614 1716 1816 2016 2116 2416 2418 2618 2818 3018 3218COOLING ONLYCooling capacity (1) kW 362 387 425 471 524 559 581 637 680 724 775 813 850Total power input (1) kW 122 128 145 157 173 185 192 217 230 244 256 272 289EER 2,96 3,03 2,94 3,01 3,04 3,03 3,03 2,94 2,95 2,96 3,03 2,99 2,94HEATING ONLYHeating capacity (2) kW 394 420 462 507 546 603 630 693 729 788 840 882 924Total power input (2) kW 120 127 140 155 166 183 190 210 221 2394 253 266 280COP 3,30 3,31 3,30 3,28 3,29 3,30 3,32 3,30 3,29 3,29 3,32 3,31 3,30COOLING WITH TOTAL RECOVERYCooling capacity (3) kW 355 379 423 460 500 547 569 636 667 711 758 802 848Heat recovery capacity (3) kW 394 485 542 590 640 700 728 814 854 912 971 1027 1085Total power input (3) kW 107 113 126 139 150 163 170 189 200 213 227 240 252TER (4) - 7,00 7,65 7,66 7,55 7,60 7,65 7,63 7,67 7,61 7,62 7,62 7,62 7,67COMPRESSORSNo. Compressors/No. Circuits N. 4 / 2 4 / 2 4 / 2 6 / 3 6 / 3 6 / 3 6 / 3 6 / 3 8 / 4 8 / 4 8 / 4 8 / 4 8 / 4NOISE LEVELSSound power (5) dB(A) 97 97 97 97 98 98 98 99 99 99 100 100 100Sound pressure (6) dB(A) 65 65 65 64 65 65 65 66 66 66 67 67 67SIZEA mm 5080 5080 5080 6255 7430 7430 7430 7430 9780 9780 9780 9780 9780B mm 2260 2260 2260 2260 2260 2260 2260 2260 2260 2260 2260 2260 2260H mm 2450 2450 2450 2450 2450 2450 2450 2450 2450 2450 2450 2450 2450Operating weight kg 3850 3950 3980 5460 5740 5890 5970 6020 7350 7500 7700 7740 7770

Note:

1 Evaporator water (in/out) = 12/7°C; Condenser air (in) = 35°C.

2 Condenser water (in/out) = 40/45°C; evaporator air (in) = 7°C - r.h. 87%.

3 Evaporator water (in/out) = 12/7°C; Recovery unit water (in/out) = 40/45°C

4 TER := Total Efficiency Ratio = (Cooling capacity + Heating capacity) / (Total power input)

5 Sound power on the basis of measurements made in compliance with ISO 9614 and Eurovent 8/1 for Eurovent certified units; in compliance with ISO 3744 for non-certified units.

6 Average sound pressure level, at 10m distance, unit in a free field on a reflective surface; non-binding value obtained from the sound power level.

NECS-Q / BModels 1314 1414 1614 1716 1816 2016 2116 2416 2418 2618 2818 3018 3218COOLING ONLYCooling capacity (1) kW 353 378 412 452 494 546 567 617 662 704 757 791 823Total power input (1) kW 125 131 150 163 176 189 196 225 235 250 262 281 300EER 2,81 2,89 2,75 2,77 2,82 2,89 2,89 2,74 2,82 2,81 2,89 2,82 2,74HEATING ONLYHeating capacity (2) kW 380 408 447 485 528 587 612 670 704 761 817 855 893Total power input (2) kW 121 129 142 156 169 186 192 212 225 243 256 270 283COP 3,13 3,18 3,16 3,11 3,12 3,16 3,18 3,16 3,12 3,13 3,18 3,17 3,16COOLING WITH TOTAL RECOVERYCooling capacity (3) kW 355 379 423 460 500 547 569 636 667 711 758 802 848Heat recovery capacity (3) kW 455 485 542 590 640 700 728 814 854 912 971 240 1085Total power input (3) kW 107 113 126 139 150 163 170 189 200 213 227 1027 252TER (4) - 7,57 7,65 7,66 7,55 7,60 7,65 7,63 7,67 7,61 7,62 7,62 1,01 7,67COMPRESSORSNo. Compressors/No. Circuits N. 4 / 2 4 / 2 4 / 2 6 / 3 6 / 3 6 / 3 6 / 3 6 / 3 8 / 4 8 / 4 8 / 4 8 / 4 8 / 4NOISE LEVELSSound power (5) dB(A) 96 96 96 96 97 97 97 98 98 98 99 99 99Sound pressure (6) dB(A) 64 64 64 64 65 65 65 66 65 65 66 66 66SIZEA mm 3905 3905 3905 4515 5690 5690 5690 5690 7430 7430 7430 7430 7430B mm 2260 2260 2260 2260 2260 2260 2260 2260 2260 2260 2260 2260 2260H mm 2450 2450 2450 2450 2450 2450 2450 2450 2450 2450 2450 2450 2450Operating weight kg 3530 3620 3650 4850 5240 5370 5430 5480 6700 6830 7000 7030 7060

SYSTEM

4 PIPE

SCROLLAXIALSHELL & TUBESENERGY CLASS

Page 206: Products Guide V01 - ParagonEfficient project management thanks to Climaveneta as unique project leader. Complete and specialized Organization Climaveneta qualifies itself for the

204

Minimum clearance required1314-3218

Switchboard side mm 1500Switchboard opposite side mm 1500Plant exchagers opposite side mm 1500Plant exchagers side mm 2000

Note:

1 Evaporator water (in/out) = 12/7°C; Condenser air (in) = 35°C.

2 Condenser water (in/out) = 40/45°C; evaporator air (in) = 7°C - r.h. 87%.

3 Evaporator water (in/out) = 12/7°C; Recovery unit water (in/out) = 40/45°C

4 TER := Total Efficiency Ratio = (Cooling capacity + Heating capacity) / (Total power input)

5 Sound power on the basis of measurements made in compliance with ISO 9614 and Eurovent 8/1 for Eurovent certified units; in compliance with ISO 3744 for non-certified units.

6 Average sound pressure level, at 10m distance, unit in a free field on a reflective surface; non-binding value obtained from the sound power level.

NECS-Q / SL-CAModels 1314 1414 1614 1716 1816 2016 2116 2416 2418 2618 2818 3018 3218COOLING ONLYCooling capacity (1) kW 332 357 398 429 500 512 536 596 616 663 715 754 795Total power input (1) kW 130 137 153 169 640 198 205 230 244 260 274 290 306EER 2,56 2,61 2,60 2,54 2,52 2,59 2,61 2,60 2,52 2,55 2,61 2,60 2,60HEATING ONLYHeating capacity (2) kW 378 400 453 486 526 578 601 679 701 755 801 859 906Total power input (2) kW 116 124 138 151 163 178 186 207 217 233 248 262 276COP 3,25 3,22 3,29 3,22 3,23 3,25 3,23 3,28 3,23 3,24 3,23 3,28 3,28COOLING WITH TOTAL RECOVERYCooling capacity (3) kW 355 379 423 460 500 547 569 636 667 711 758 802 848Heat recovery capacity (3) kW 455 485 542 590 640 700 728 814 854 912 971 240 1085Total power input (3) kW 107 113 126 139 150 163 170 189 200 213 227 1027 252TER (4) - 7,57 7,65 7,66 7,55 7,60 7,65 7,63 7,67 7,61 7,62 7,62 1,01 7,67COMPRESSORSNo. Compressors/No. Circuits N. 4 / 2 4 / 2 4 / 2 6 / 3 6 / 3 6 / 3 6 / 3 6 / 3 8 / 4 8 / 4 8 / 4 8 / 4 8 / 4NOISE LEVELSSound power (5) dB(A) 88 88 88 89 89 90 90 91 91 91 92 92 92Sound pressure (6) dB(A) 56 56 56 57 57 57 57 58 58 58 59 59 59SIZEA mm 4515 5080 5080 5690 5690 6865 7430 7430 7430 8605 9780 9780 9780B mm 2260 2260 2260 2260 2260 2260 2260 2260 2260 2260 2260 2260 2260H mm 2450 2450 2450 2450 2450 2450 2450 2450 2450 2450 2450 2450 2450Operating weight kg 3760 3900 4050 5350 5490 5780 5890 6130 7020 7330 7600 7750 7910

AB

H

Page 207: Products Guide V01 - ParagonEfficient project management thanks to Climaveneta as unique project leader. Complete and specialized Organization Climaveneta qualifies itself for the

205

Page 208: Products Guide V01 - ParagonEfficient project management thanks to Climaveneta as unique project leader. Complete and specialized Organization Climaveneta qualifies itself for the

206

Main accessoriesHydronic group

VPF (Variable Primary Flow) kit: variable flow pumps with on board regulation

Electronic expansion valve

Set-up for remote connectivity with ModBus/Echelon/Bacnet protocol cards

FeaturesUNIQUE PROPOSAL

Unit designed to satisfy the cold and the hot side requirements simultaneously, for 4-pipe systems without any particular operation mode setting

ENERGY SAVING

Energy saving guaranteed by the advanced operations logic. The best operation mode is set completely automatically and independently by the units controller, in order to minimize the absorbed energy whatever the cooling and/or heating demand might be

EXTENSIVE RANGE OF OPERATION

Unit´s operation guaranteed with external air temperature down to -10°C during winter and up to 46°C during summer.

VERSION ´XL-CA-E´ AVAILABLE

Exclusive Premium version. Together for the first time, the lowest noise level on the market and the maximum efficiency in each operating mode.

HOT WATER SUPPLY

Supply of hot water in use up to 55°C, offering maximum versatility with respect to different plant engineering solutions

VersionsCA Class A of efficiency

LN-CA Low Noise, Class A of efficiency

SL-CA Super Low noise version, Class A of efficiency

XL-CA eXtra Low noise version, Class A of efficiency

XL-CA-E eXtra Low noise, Class A enhanced

CommandsW3000 largeThe controller W3000 large offers the latest control and functions specially developed for these units. The keypad is generously sized with full operating status display. The controls and detailed LCD make access to machine settings easy and safe. These resources permit to diirectly act on the unit settings through a multilevel menu, available in several languages. The diagnostics includes full management of alarms with black-box functions and alarm record for better analysis of unit performance. For multi-units plants a special device to coordinate and manage all the resources is available as an option; energy metering device is even possible as an option. Supervision is easy through Climaveneta devices or with various options for interfacing to ModBus, Bacnet, Echelon LonTalk protocols. Compatibility with remote keyboard (management up to 10 units). Clock available with programming of operation (standard 4 days and 10 time bands). Temperature regulation managed on the two water circuits, with a proportional logic referred to the return water temperatures. This allows to satisfy simultaneously the different heating- and cooling requests, with no need of mode changeover. Exclusive self-adaptive defrost logic, monitoring multiple operational- and ambient parameters, which allows to reduce the number and duration of the defrost cycles, with a benefit for the overall energy efficiency.

INTEGRA

ERACS2-Q 1062÷3222

INTEGRA unit for 4-pipe systems, air source for outdoor installation

200 - 826 kWUnit DescriptionMulti-purpose outdoor unit for use in 4-pipe systems for the simultaneous production of chilled and hot water by means of two independent hydronic circuits. These units are able to satisfy the demand for hot and cold water simultaneously through a system that does not require seasonal switching and is therefore a valid alternative to traditional plants with chiller and boiler. Each circuit works with a semi-hermetic screw compressor using R134a, two shell and tubes heat exchangers shared by both circuits, a cold heat exchanger on plants side that acts as an evaporator in the production of cold water, a heat exchanger on plants side that works as a condenser in the production of hot water, and a source side coil heat exchanger that works as either condenser or evaporator as required by the loads.

Page 209: Products Guide V01 - ParagonEfficient project management thanks to Climaveneta as unique project leader. Complete and specialized Organization Climaveneta qualifies itself for the

207

Note:

1 Evaporator water (in/out) = 12/7°C; Condenser air (in) = 35°C.

2 Condenser water (in/out) = 40/45°C; evaporator air (in) = 7°C - r.h. 87%.

3 Evaporator water (in/out) = 12/7°C; Recovery unit water (in/out) = 40/45°C

4 TER := Total Efficiency Ratio = (Cooling capacity + Heating capacity) / (Total power input)

5 Sound power on the basis of measurements made in compliance with ISO 9614 and Eurovent 8/1 for Eurovent certified units; in compliance with ISO 3744 for non-certified units.

6 Average sound pressure level, at 10m distance, unit in a free field on a reflective surface; non-binding value obtained from the sound power level.

ERACS2-Q / LN-CAModels 1062 1162 1362 1562 1762 1962 2022 2222 2422 2622 2722 3222COOLING ONLYCooling capacity (1) kW 205 241 294 322 369 414 469 513 541 604 686 800Total power input (1) kW 70,8 84,3 103 109 130 144 163 168 177 206 226 274EER 2,90 2,86 2,85 2,95 2,84 2,88 2,88 3,05 3,06 2,93 3,04 2,92HEATING ONLYHeating capacity (2) kW 218 258 309 339 396 434 492 541 571 615 711 826Total power input (2) kW 67 80,7 92,2 101 122 131 149 159 169 178 207 240COP 3,25 3,20 3,35 3,36 3,25 3,31 3,30 3,40 3,38 3,46 3,43 3,44COOLING WITH TOTAL RECOVERYCooling capacity (3) kW 209 248 305 329 381 428 484 521 551 631 702 832Heat recovery capacity (3) kW 269 320 392 422 493 549 621 666 704 801 895 1056Total power input (3) kW 60,6 71,9 87,1 92,5 111 122 137 145 153 170 193 224TER (4) - 7,89 7,90 8,00 8,12 7,87 8,01 8,07 8,19 8,20 8,42 8,27 8,43COMPRESSORSNo. Compressors/No. Circuits N. 2 / 2 2 / 2 2 / 2 2 / 2 2 / 2 2 / 2 2 / 2 2 / 2 2 / 2 2 / 2 2 / 2 2 / 2NOISE LEVELSSound power (5) dB(A) 90 91 91 92 92 92 93 95 95 95 95 96Sound pressure (6) dB(A) 58 59 59 60 60 60 61 63 63 63 63 64SIZEA mm 4610 4610 5610 5610 6610 6610 6300 7200 7200 7200 8400 9700B mm 2220 2220 2220 2220 2220 2220 2260 2260 2260 2260 2260 2260H mm 2150 2420 2430 2430 2430 2430 2350 2350 2350 2350 2350 2350Operating weight kg * * * * * * * * * * * *

Note:

1 Evaporator water (in/out) = 12/7°C; Condenser air (in) = 35°C.

2 Condenser water (in/out) = 40/45°C; evaporator air (in) = 7°C - r.h. 87%.

3 Evaporator water (in/out) = 12/7°C; Recovery unit water (in/out) = 40/45°C

4 TER := Total Efficiency Ratio = (Cooling capacity + Heating capacity) / (Total power input)

5 Sound power on the basis of measurements made in compliance with ISO 9614 and Eurovent 8/1 for Eurovent certified units; in compliance with ISO 3744 for non-certified units.

6 Average sound pressure level, at 10m distance, unit in a free field on a reflective surface; non-binding value obtained from the sound power level.

ERACS2-Q / CAModels 1062 1162 1362 1562 1762 1962 2022 2222 2422 2622 2722 3222COOLING ONLYCooling capacity (1) kW 210 248 302 329 380 425 483 525 554 624 701 826Total power input (1) kW 72,1 84,5 102 109 129 144 156 167 176 201 222 264EER 2,91 2,93 2,96 3,02 2,95 2,95 3,10 3,14 3,15 3,10 3,16 3,13HEATING ONLYHeating capacity (2) kW 218 258 309 339 396 434 492 541 571 615 711 826Total power input (2) kW 67 80,7 92,2 101 122 131 149 159 169 178 207 240COP 3,25 3,20 3,35 3,36 3,25 3,31 3,30 3,40 3,38 3,46 3,43 3,44COOLING WITH TOTAL RECOVERYCooling capacity (3) kW 209 248 305 329 381 428 484 521 551 631 702 832Heat recovery capacity (3) kW 269 320 392 422 493 549 621 666 704 801 895 1056Total power input (3) kW 60,6 71,9 87,1 92,5 111 122 137 145 153 170 193 224TER (4) - 7,89 7,90 8,00 8,12 7,87 8,01 8,07 8,19 8,20 8,42 8,27 8,43COMPRESSORSNo. Compressors/No. Circuits N. 2 / 2 2 / 2 2 / 2 2 / 2 2 / 2 2 / 2 2 / 2 2 / 2 2 / 2 2 / 2 2 / 2 2 / 2NOISE LEVELSSound power (5) dB(A) 97 97 97 98 99 99 99 101 101 101 101 102Sound pressure (6) dB(A) 65 65 65 66 67 67 67 69 69 69 69 70SIZEA mm 4610 4610 5610 5610 6610 6610 6300 7200 7200 7200 8400 9700B mm 2220 2220 2220 2220 2220 2220 2260 2260 2260 2260 2260 2260H mm 2150 2420 2430 2430 2430 2430 2350 2350 2350 2350 2350 2350Operating weight kg * * * * * * * * * * * *

SYSTEM

4 PIPE

r HFCR-134a

SCREWAXIALSHELL & TUBES

Page 210: Products Guide V01 - ParagonEfficient project management thanks to Climaveneta as unique project leader. Complete and specialized Organization Climaveneta qualifies itself for the

208

Note:

1 Evaporator water (in/out) = 12/7°C; Condenser air (in) = 35°C.

2 Condenser water (in/out) = 40/45°C; evaporator air (in) = 7°C - r.h. 87%.

3 Evaporator water (in/out) = 12/7°C; Recovery unit water (in/out) = 40/45°C

4 TER := Total Efficiency Ratio = (Cooling capacity + Heating capacity) / (Total power input)

5 Sound power on the basis of measurements made in compliance with ISO 9614 and Eurovent 8/1 for Eurovent certified units; in compliance with ISO 3744 for non-certified units.

6 Average sound pressure level, at 10m distance, unit in a free field on a reflective surface; non-binding value obtained from the sound power level.

ERACS2-Q / XL-CAModels 2022 2222 2422 2622 2722 3222COOLING ONLYCooling capacity (1) kW 455 501 528 584 667 772Total power input (1) kW 167 169 180 212 230 287EER 2,72 2,96 2,93 2,75 2,90 2,69HEATING ONLYHeating capacity (2) kW 486 536 564 607 703 816Total power input (2) kW 143 152 161 170 198 230COP 3,40 3,53 3,50 3,57 3,55 3,55COOLING WITH TOTAL RECOVERYCooling capacity (3) kW 484 521 551 631 702 832Heat recovery capacity (3) kW 621 666 704 801 895 1056Total power input (3) kW 137 145 153 170 193 224TER (4) - 8,07 8,19 8,20 8,42 8,27 8,43COMPRESSORSNo. Compressors/No. Circuits N. 2 / 2 2 / 2 2 / 2 2 / 2 2 / 2 2 / 2NOISE LEVELSSound power (5) dB(A) 85 87 87 87 87 88Sound pressure (6) dB(A) 53 55 55 55 55 56SIZEA mm 6300 7200 7200 7200 8400 9700B mm 2260 2260 2260 2260 2260 2260H mm 2350 2350 2350 2350 2350 2350Operating weight kg * * * * * *

Note:

1 Evaporator water (in/out) = 12/7°C; Condenser air (in) = 35°C.

2 Condenser water (in/out) = 40/45°C; evaporator air (in) = 7°C - r.h. 87%.

3 Evaporator water (in/out) = 12/7°C; Recovery unit water (in/out) = 40/45°C

4 TER := Total Efficiency Ratio = (Cooling capacity + Heating capacity) / (Total power input)

5 Sound power on the basis of measurements made in compliance with ISO 9614 and Eurovent 8/1 for Eurovent certified units; in compliance with ISO 3744 for non-certified units.

6 Average sound pressure level, at 10m distance, unit in a free field on a reflective surface; non-binding value obtained from the sound power level.

ERACS2-Q / SL-CAModels 1062 1162 1362 1562 1762 1962 2022 2222 2422 2622 2722 3222COOLING ONLYCooling capacity (1) kW 200 233 283 314 356 401 464 509 537 597 680 790Total power input (1) kW 72,7 87,2 109 113 137 149 166 170 180 210 229 281EER 2,75 2,67 2,60 2,78 2,60 2,69 2,80 2,99 2,98 2,84 2,97 2,81HEATING ONLYHeating capacity (2) kW 211 251 301 330 385 422 486 536 564 607 703 816Total power input (2) kW 64,8 78,4 89,9 98,4 119 127 147 157 167 176 205 238COP 3,26 3,20 3,35 3,35 3,24 3,32 3,31 3,41 3,38 3,45 3,43 3,43COOLING WITH TOTAL RECOVERYCooling capacity (3) kW 209 248 305 329 381 428 484 521 551 631 702 832Heat recovery capacity (3) kW 269 320 392 422 493 549 621 666 704 801 895 1056Total power input (3) kW 60,6 71,9 87,1 92,5 111 122 137 145 153 170 193 224TER (4) - 7,89 7,90 8,00 8,12 7,87 8,01 8,07 8,19 8,20 8,42 8,27 8,43COMPRESSORSNo. Compressors/No. Circuits N. 2 / 2 2 / 2 2 / 2 2 / 2 2 / 2 2 / 2 2 / 2 2 / 2 2 / 2 2 / 2 2 / 2 2 / 2NOISE LEVELSSound power (5) dB(A) 86 87 87 88 88 88 89 91 91 91 91 92Sound pressure (6) dB(A) 54 55 55 56 56 56 57 59 59 59 59 60SIZEA mm 4610 4610 5610 5610 6610 6610 6300 7200 7200 7200 8400 9700B mm 2220 2220 2220 2220 2220 2220 2260 2260 2260 2260 2260 2260H mm 2150 2420 2430 2430 2430 2430 2350 2350 2350 2350 2350 2350Operating weight kg * * * * * * * * * * * *

Page 211: Products Guide V01 - ParagonEfficient project management thanks to Climaveneta as unique project leader. Complete and specialized Organization Climaveneta qualifies itself for the

209

Minimum clearance required1062-1762 2022-2622

Switchboard side mm 1100 1800Switchboard opposite side mm 1100 1500Condensation coil side mm 2000 2000

Note:

1 Evaporator water (in/out) = 12/7°C; Condenser air (in) = 35°C.

2 Condenser water (in/out) = 40/45°C; evaporator air (in) = 7°C - r.h. 87%.

3 Evaporator water (in/out) = 12/7°C; Recovery unit water (in/out) = 40/45°C

4 TER := Total Efficiency Ratio = (Cooling capacity + Heating capacity) / (Total power input)

5 Sound power on the basis of measurements made in compliance with ISO 9614 and Eurovent 8/1 for Eurovent certified units; in compliance with ISO 3744 for non-certified units.

6 Average sound pressure level, at 10m distance, unit in a free field on a reflective surface; non-binding value obtained from the sound power level.

ERACS2-Q / XL-CA-EModels 1062 1162 1362 1562 1762 2022 2222 2422 2622COOLING ONLYCooling capacity (1) kW 204 247 293 319 366 473 510 541 611Total power input (1) kW 66,6 76,6 99,4 105 127 153 163 169 193EER 3,06 3,22 2,95 3,04 2,88 3,09 3,13 3,20 3,17HEATING ONLYHeating capacity (2) kW 218 267 308 340 393 513 552 588 644Total power input (2) kW 62,4 77,6 88,3 95,2 116 145 154 164 176COP 3,49 3,44 3,49 3,57 3,39 3,54 3,58 3,59 3,66COOLING WITH TOTAL RECOVERYCooling capacity (3) kW 209 248 305 329 381 484 521 551 631Heat recovery capacity (3) kW 269 320 392 422 493 621 666 704 801Total power input (3) kW 60,6 71,9 87,1 92,5 111 137 145 153 170TER (4) - 7,89 7,90 8,00 8,12 7,87 8,07 8,19 8,20 8,42COMPRESSORSNo. Compressors/No. Circuits N. 2 / 2 2 / 2 2 / 2 2 / 2 2 / 2 2 / 2 2 / 2 2 / 2 2 / 2NOISE LEVELSSound power (5) dB(A) 85 86 86 87 87 86 88 88 88Sound pressure (6) dB(A) 53 54 54 55 55 54 56 56 56SIZEA mm 4610 5610 5610 6610 6610 8400 9300 9300 9300B mm 2220 2220 2220 2220 2220 2260 2260 2260 2260H mm 2420 2430 2430 2430 2430 2350 2350 2350 2350Operating weight kg * * * * * * * * *

Page 212: Products Guide V01 - ParagonEfficient project management thanks to Climaveneta as unique project leader. Complete and specialized Organization Climaveneta qualifies itself for the

210

Main accessoriesHydronic group

VPF (Variable Primary Flow) kit: variable flow pumps with on board regulationSet-up for remote connectivity with ModBus/Echelon/Bacnet protocol cards

FeaturesUNIQUE PROPOSAL - PATENT PENDING

The exclusive regulation´s logic of the INTEGRA units, the only able to satisfy cold and hot building loads simultaneously, and the use of inverter motors ensure the highest energy saving for complex plants, as the 4-pipes system are

VERY HIGH EFFICIENCY AT PARTIAL LOAD

Very high efficiency at partial load thanks to the inverter technology applied on screw compressors. Therefore, operating costs are reduced to a minimum

TRUE SILENCE

Silence optimized for the most frequent operational conditions, thanks to the accurate structures design, to the use of EC fans (DC brushless) and to the adoption of variable-speed driven compressors

EXTENSIVE RANGE OF OPERATION

Unit´s operation guaranteed with external air temperature down to -10°C during winter and up to 46°C during summer.

HARMONY BETWEEN UNIT AND PLANT

Low inrush current and cos(phi) higher than 0.9, permit an easy electrical installation which is not stressed during start-up and with no need of extra devices for power factor correction. The use of inverter allows the unit partialize down to 15%, with consequent lower fluctuations of leaving water temperature

VersionsCA Class A of efficiency

LN-CA Low Noise, Class A of efficiency

SL-CA Super Low noise version, Class A of efficiency

CommandsW3000SE LargeThe W3000SE Large controller offers advanced functions and algorithms. The keypad features an easy-to-use interface and a complete LCD display, allowing to consult and intervene on the unit by means of a multi-level menu, with selectable language setting. The regulation operates on both water circuits and features the continuous modulation of capacity by adjustment of the compressor speed. The modulation is based on PID algorithms and referring to the leaving water temperature. This is combined with the management of the compressors status, with two selectable logics (proportional referred to the return temperature or dead band referred to the leaving temperature). This allows to satisfy simultaneously and accurately the different requests of both cooling and heating, with no need of mode setting. The diagnostics includes a complete alarm management, with the “black-box” and alarm logging functions for enhanced analysis of the unit operation. For multiple units systems, the regulation of the resources, via optional proprietary devices, can be implemented. Energy metering, for both consumption and capacity, can also be developed. Supervision can be easily developed via proprietary devices or the integration in third party systems by means of the most common protocols as ModBus, Bacnet, Bacnet-over-IP, Echelon LonWorks. Compatibility with the remote keyboard managing up to 10 units. Availability of an internal real time clock for operation scheduling (4-day profiles with 10 hour belts). The defrost adopts a proprietary self-adaptive logic, which features the monitoring of numerous operational parameters. This allows to reduce the number and duration of the defrost cycles, with a benefit for the overall energy efficiency.

INTEGRA

i-FX-Q 0502÷0802

INTEGRA unit for 4-pipe systems, air source for outdoor installation

479 - 811 kWUnit DescriptionMulti-purpose outdoor unit for use in 4-pipe systems for the simultaneous production of chilled and hot water by means of two independent hydronic circuits. These units are able to satisfy the demand for hot and cold water simultaneously through a system that does not require seasonal switching and is therefore a valid alternative to traditional plants with chiller and boiler. Each circuit works with an inverter driven semi-hermetic screw compressor using R134a, two shell and tubes heat exchangers shared by both circuits, a cold heat exchanger and a hot one on plants side, and a source side coil heat exchanger that works as either condenser or evaporator as required by the loads. The revolutionary units design, patent pending, and the use of inverter motors on compressors, fans and, on request, on pumps, ensures un umbeatable efficiency, specially at part load.

Page 213: Products Guide V01 - ParagonEfficient project management thanks to Climaveneta as unique project leader. Complete and specialized Organization Climaveneta qualifies itself for the

211

Note:

1 Evaporator water (in/out) = 12/7°C; Condenser air (in) = 35°C.

2 Condenser water (in/out) = 40/45°C; evaporator air (in) = 7°C - r.h. 87%.

3 Evaporator water (in/out) = 12/7°C; Recovery unit water (in/out) = 40/45°C

4 TER := Total Efficiency Ratio = (Cooling capacity + Heating capacity) / (Total power input)

5 Sound power on the basis of measurements made in compliance with ISO 9614 and Eurovent 8/1 for Eurovent certified units; in compliance with ISO 3744 for non-certified units.

6 Average sound pressure level, at 10m distance, unit in a free field on a reflective surface; non-binding value obtained from the sound power level.

i-FX-Q / LN-CAModels 0502 0602 0702 0802COOLING ONLYCooling capacity (1) kW 484 599 690 787Total power input (1) kW 159 206 243 271EER 3,04 2,91 2,84 2,90HEATING ONLYHeating capacity (2) kW 528 654 758 856Total power input (2) kW 155 194 224 249COP 3,41 3,37 3,38 3,44COOLING WITH TOTAL RECOVERYCooling capacity (3) kW 485 613 715 814Heat recovery capacity (3) kW 624 787 917 1040Total power input (3) kW 147 185 215 240TER (4) - 7,54 7,57 7,59 7,72COMPRESSORSNo. Compressors/No. Circuits N. 2 / 2 2 / 2 2 / 2 2 / 2NOISE LEVELSSound power (5) dB(A) * * * *Sound pressure (6) dB(A) * * * *SIZEA mm 7800 9000 9000 9900B mm 2260 2260 2260 2260H mm 2430 2430 2430 2430Operating weight kg * * * *

Note:

1 Evaporator water (in/out) = 12/7°C; Condenser air (in) = 35°C.

2 Condenser water (in/out) = 40/45°C; evaporator air (in) = 7°C - r.h. 87%.

3 Evaporator water (in/out) = 12/7°C; Recovery unit water (in/out) = 40/45°C

4 TER := Total Efficiency Ratio = (Cooling capacity + Heating capacity) / (Total power input)

5 Sound power on the basis of measurements made in compliance with ISO 9614 and Eurovent 8/1 for Eurovent certified units; in compliance with ISO 3744 for non-certified units.

6 Average sound pressure level, at 10m distance, unit in a free field on a reflective surface; non-binding value obtained from the sound power level.

i-FX-Q / CAModels 0502 0602 0702 0802COOLING ONLYCooling capacity (1) kW 498 617 711 811Total power input (1) kW 164 210 245 273EER 3,04 2,94 2,90 2,97HEATING ONLYHeating capacity (2) kW 528 654 758 856Total power input (2) kW 155 194 224 249COP 3,41 3,37 3,38 3,44COOLING WITH TOTAL RECOVERYCooling capacity (3) kW 485 613 715 814Heat recovery capacity (3) kW 624 787 917 1040Total power input (3) kW 147 185 215 240TER (4) - 7,54 7,57 7,59 7,72COMPRESSORSNo. Compressors/No. Circuits N. 2 / 2 2 / 2 2 / 2 2 / 2NOISE LEVELSSound power (5) dB(A) * * * *Sound pressure (6) dB(A) * * * *SIZEA mm 7800 9000 9000 9900B mm 2260 2260 2260 2260H mm 2430 2430 2430 2430Operating weight kg * * * *

SYSTEM

4 PIPE

r HFCR-134a

SCREWEC FANSHELL & TUBES

Page 214: Products Guide V01 - ParagonEfficient project management thanks to Climaveneta as unique project leader. Complete and specialized Organization Climaveneta qualifies itself for the

212

Minimum clearance required0502-0802

Switchboard side mm 1800Switchboard opposite side mm 1500Condensation coil side mm 2000

Note:

1 Evaporator water (in/out) = 12/7°C; Condenser air (in) = 35°C.

2 Condenser water (in/out) = 40/45°C; evaporator air (in) = 7°C - r.h. 87%.

3 Evaporator water (in/out) = 12/7°C; Recovery unit water (in/out) = 40/45°C

4 TER := Total Efficiency Ratio = (Cooling capacity + Heating capacity) / (Total power input)

5 Sound power on the basis of measurements made in compliance with ISO 9614 and Eurovent 8/1 for Eurovent certified units; in compliance with ISO 3744 for non-certified units.

6 Average sound pressure level, at 10m distance, unit in a free field on a reflective surface; non-binding value obtained from the sound power level.

i-FX-Q / SL-CAModels 0502 0602 0702 0802COOLING ONLYCooling capacity (1) kW 479 592 681 777Total power input (1) kW 158 207 245 273EER 3,03 2,86 2,78 2,85HEATING ONLYHeating capacity (2) kW 523 649 750 847Total power input (2) kW 152 191 220 244COP 3,44 3,40 3,41 3,47COOLING WITH TOTAL RECOVERYCooling capacity (3) kW 485 613 715 814Heat recovery capacity (3) kW 624 787 917 1040Total power input (3) kW 147 185 215 240TER (4) - 7,54 7,57 7,59 7,72COMPRESSORSNo. Compressors/No. Circuits N. 2 / 2 2 / 2 2 / 2 2 / 2NOISE LEVELSSound power (5) dB(A) * * * *Sound pressure (6) dB(A) * * * *SIZEA mm 7800 9000 9000 9900B mm 2260 2260 2260 2260H mm 2430 2430 2430 2430Operating weight kg * * * *

Page 215: Products Guide V01 - ParagonEfficient project management thanks to Climaveneta as unique project leader. Complete and specialized Organization Climaveneta qualifies itself for the

213

Page 216: Products Guide V01 - ParagonEfficient project management thanks to Climaveneta as unique project leader. Complete and specialized Organization Climaveneta qualifies itself for the

214

Main accessoriesRemote keyboard (distance to 200m and to 500m)

Set-up for remote connectivity with ModBus, Echelon LonTalk, Bacnet protocol board

Acoustical enclosure to reduce the noise emissions.

Water connections directed upwards (for 2 compressors units only)

FeaturesREFRIGERANT GAS R410A

The use of R410A has resulted in units offering better energy efficiency in full respect for the environment (ODP = 0)

INTEGRATED CONDENSATION´S CONTROL

A 2 way valve is supplied as standard for the condensing pressure control. For all the applications in which a constant waterflow through the condenser is needed, a 3-way valve option is also available under request.

ENERGY SAVING

Energy saving guaranteed by the advanced operations logic. The best operation mode is set completely automatically and independently by the units controller, in order to minimize the absorbed energy whatever the cooling and/or heating demand might be

HOT WATER SUPPLY

Production of hot water up to 54°C to meet the most demanding application needs.

VersionsB base version

CommandsW3000 largeThe controller W3000 large offers the latest control and functions developed directly by Climaveneta on the basis of their experience gained over the years with these particular units and the related plant engineering. The keypad is generously sized with full operating status display. The controls and detailed LCD make access to machine settings easy and safe. Temperature regulation managed on the two water circuits, with a proportional logic referred to the return water temperatures. This allows to satisfy simultaneously the different heating- and cooling requests, with no need of mode changeover. The diagnostics includes full management of alarms with black-box functions and alarm record for better analysis of unit performance. Supervision is easy through Climaveneta devices or with various options for interfacing to ModBus, Bacnet, Echelon LonTalk protocols. Compatibility with remote keyboard (management up to 10 units). Clock available with programming of operation (standard 4 days and 10 time bands). Exclusive self-adaptive defrost logic, monitoring multiple operational- and ambient parameters, which allows to reduce the number and duration of the defrost cycles, with a benefit for the overall energy efficiency.

INTEGRA

NECS-WQ 0152÷1604

INTEGRA unit for 4-pipe systems, water source

45,7 - 491 kWUnit DescriptionMulti-purpose indoor unit for use in 4-pipe systems for the simultaneous production of chilled and hot water by means of two independent water circuits. These units are able to satisfy the demand for hot and cold water simultaneously through a system that does not require seasonal switching. Water-source unit equipped with hermetic rotary Scroll compressors, with R410A, plate heat exchangers and thermostatic expansion valve. The range is composed by units equipped with two and four compressors, all with two independent refrigerant circuits.

Page 217: Products Guide V01 - ParagonEfficient project management thanks to Climaveneta as unique project leader. Complete and specialized Organization Climaveneta qualifies itself for the

215

Minimum clearance required0152-0612 0604-1604

Switchboard side mm 800 1000Switchboard opposite side mm 800 1000Condensation coil side mm 800 800

Note:

1 Evaporator water (in/out) = 12/7°C; condenser water (in/out) = 14/30°C

2 Condenser water (in/out) = 40/45°C; evaporator water (in/out) = 14/7°C

3 Evaporator water (in/out) = 12/7°C; Recovery unit water (in/out) = 40/45°C

4 TER := Total Efficiency Ratio = (Cooling capacity + Heating capacity) / (Total power input)

5 Sound power on the basis of measurements made in compliance with ISO 9614 and Eurovent 8/1 for Eurovent certified units; in compliance with ISO 3744 for non-certified units.

6 Average sound pressure level, at 1 m distance, unit in a free field on a reflective surface; non-binding value obtained from the sound power level.

7 Unit in standard configuration/execution, without optional accessories

Models 0604 0704 0804 0904 1004 1104 1204 1404 1604COOLING ONLYCooling capacity (1) kW 194 225 255 285 317 365 413 468 522Total power input (1) kW 34,8 40 45,3 50,8 56,3 64,8 73 84,1 95,1EER 5,58 5,63 5,62 5,61 5,63 5,63 5,66 5,56 5,49HEATING ONLYHeating capacity (2) kW 208 240 270 303 338 388 440 498 557Total power input (2) kW 47,7 54,7 61,8 69,2 76,8 88,4 99,6 113 126COP 4,36 4,38 4,37 4,38 4,40 4,39 4,41 4,41 4,42COOLING WITH TOTAL RECOVERYCooling capacity (3) kW 163 188 212 238 266 305 346 392 438Heat recovery capacity (3) kW 208 240 270 303 338 388 440 498 557Total power input (3) kW 47,7 54,7 61,8 69,2 76,8 88,4 99,6 113 126TER (4) - 7,78 7,82 7,80 7,82 7,86 7,84 7,89 7,88 7,90COMPRESSORSNo. Compressors/No. Circuits N. 4 / 2 4 / 2 4 / 2 4 / 2 4 / 2 4 / 2 4 / 2 4 / 2 4 / 2NOISE LEVELSTotal power input kWSound power (5) dB(A) 86 87 88 89 90 91 91 91 91Sound pressure (6) dB(A) 54 55 56 57 58 59 59 59 59SIZEA (7) mm 2520 2520 2520 2520 2520 2520 2520 2520 2520B (7) mm 880 880 880 880 880 880 880 880 880H (7) mm 1810 1810 1810 1810 1810 1810 1810 1810 1810Operating weight (7) kg 975 1165 1365 1445 1610 1710 1810 1895 2000

NECS-WQ / BModels 0152 0182 0202 0252 0262 0302 0412 0512 0612COOLING ONLYCooling capacity (1) kW 48,6 55,8 65 73,8 83,2 97,5 127 159 206Total power input (1) kW 8,70 9,80 11,3 13,2 14,7 17,4 22,7 28,1 36,5EER 5,59 5,69 5,75 5,59 5,66 5,60 5,59 5,64 5,63HEATING ONLYHeating capacity (2) kW 52,1 59,7 69,3 79 88,9 104 135 169 219Total power input (2) kW 12,4 13,8 16,2 18,5 20,4 23,9 31 38,4 49,9COP 4,20 4,33 4,28 4,28 4,36 4,37 435 4,40 4,38COOLING WITH TOTAL RECOVERYCooling capacity (3) kW 40,4 46,7 54,1 61,7 67,9 82 106 133 172Heat recovery capacity (3) kW 52,1 59,7 69,3 79 88,9 104 135 169 219Total power input (3) kW 12,4 13,8 16,2 18,5 20,4 23,9 31 38,4 49,9TER (4) - 7,46 7,71 7,62 7,61 7,69 7,78 7,77 7,86 7,84COMPRESSORSNo. Compressors/No. Circuits N. 2 / 2 2 / 2 2 / 2 2 / 2 2 / 2 2 / 2 2 / 2 2 / 2 2 / 2NOISE LEVELSTotal power input kWSound power (5) dB(A) 73 74 74 74 75 76 77 78 79Sound pressure (6) dB(A) 42 43 43 43 44 45 46 47 48SIZEA (7) mm 1222 1222 1222 1222 1222 1222 1222 1222 1222B (7) mm 893 893 893 893 893 893 893 893 893H (7) mm 1496 1496 1496 1496 1496 1496 1496 1496 1496Operating weight (7) kg 450 470 490 505 525 550 745 825 910

SYSTEM

4 PIPE

r HFCR-410A

SCROLLPLATES

H

BA

H

B A

Page 218: Products Guide V01 - ParagonEfficient project management thanks to Climaveneta as unique project leader. Complete and specialized Organization Climaveneta qualifies itself for the

216

Main accessoriesIntegral acoustical enclosure (type base or plus)

Several devices for condensation´s control

Electronic expansion valve

Set-up for remote connectivity with ModBus/Echelon/Bacnet protocol cards

FeaturesUNIQUE PROPOSAL

Unit designed to satisfy the cold and the hot side requirements simultaneously, for 4-pipe systems without any particular operation mode setting

ENERGY SAVING

Energy saving guaranteed by the advanced operations logic. The best operation mode is set completely automatically and independently by the units controller, in order to minimize the absorbed energy whatever the cooling and/or heating demand might be

EXTENSIVE RANGE OF OPERATION

Supply of hot water in use up to 55°C, offering maximum versatility with respect to different plant engineering solutions

INTEGRATED CONDENSATION´S CONTROL

A 2 way valve is supplied as standard for the condensing pressure control. For all the applications in which a constant waterflow through the condenser is needed, a 3-way valve option is also available under request.

Versions- base version

CommandsW3000SE LargeThe W3000SE Large controller offers advanced functions and algorithms. The keypad features an easy-to-use interface and a complete LCD display, allowing to consult and intervene on the unit by means of a multi-level menu, with selectable language setting. The regulation operates on both water circuits featuring the step-wise regulation referred to the return water temperature with proportional logic. This allows to satisfy simultaneously the different requests of both cooling and heating, with no need of mode setting. The diagnostics includes a complete alarm management, with the “black-box” and alarm logging functions for enhanced analysis of the unit operation. For multiple units systems, the regulation of the resources, via optional proprietary devices, can be implemented. Energy metering, for both consumption and capacity, can also be developed. Supervision can be easily developed via proprietary devices or the integration in third party systems by means of the most common protocols as ModBus, Bacnet, Bacnet-over-IP, Echelon LonWorks. Compatibility with the remote keyboard managing up to 10 units. Availability of an internal real time clock for operation scheduling (4-day profiles with 10 hour belts).

INTEGRA

ERACS2-WQ 0802÷3202

INTEGRA unit for 4-pipe systems, water source

194 - 891 kWUnit DescriptionMulti-purpose indoor unit for use in 4-pipe systems for the simultaneous production of chilled and hot water by means of two independent water circuits. These units are able to satisfy the demand for hot and cold water simultaneously through a system that does not require seasonal switching. Each circuit works with a semi-hermetic screw compressor using R134a, and three tube nest heat exchangers, a cold exchanger on the user side shared by both circuits that acts as an evaporator in the production of cold water, a heat exchanger on the user side that words as a condenser in the production of hot water, and a source side exchanger that works as either condenser or evaporator as required by the loads.

Page 219: Products Guide V01 - ParagonEfficient project management thanks to Climaveneta as unique project leader. Complete and specialized Organization Climaveneta qualifies itself for the

217

Minimum clearance required0802-3202

Switchboard side mm 800Switchboard opposite side mm 500Condensation coil side mm 500

Note:

1 Evaporator water (in/out) = 12/7°C; condenser water (in/out) = 14/30°C

2 Condenser water (in/out) = 40/45°C; evaporator water (in/out) = 14/7°C

3 Evaporator water (in/out) = 12/7°C; Recovery unit water (in/out) = 40/45°C

4 TER := Total Efficiency Ratio = (Cooling capacity + Heating capacity) / (Total power input)

5 Sound power on the basis of measurements made in compliance with ISO 9614 and Eurovent 8/1 for Eurovent certified units; in compliance with ISO 3744 for non-certified units.

6 Average sound pressure level, at 1 m distance, unit in a free field on a reflective surface; non-binding value obtained from the sound power level.

7 Unit in standard configuration/execution, without optional accessories

ERACS2-WQ / -Models 0802 1002 1102 1302 1502 1702 1902 2152 2502 2602 2702 3202COOLING ONLYCooling capacity (1) kW 194 240 275 326 373 435 479 554 648 703 781 891Total power input (1) kW 34,3 43,2 48,5 57,2 66,1 76,5 85,7 94,5 111 121 135 153EER 5,66 5,56 5,66 5,69 5,64 5,68 5,58 5,87 5,83 5,83 5,80 5,81HEATING ONLYHeating capacity (2) kW 205 255 291 344 393 459 514 589 686 738 831 941Total power input (2) kW 45,7 57 65,9 76,3 86,9 103 117 128 149 158 180 205COP 4,49 4,47 4,42 4,51 4,52 4,44 4,40 4,59 4,62 4,68 4,62 4,59COOLING WITH TOTAL RECOVERYCooling capacity (3) kW 162 201 229 272 311 362 404 468 547 589 662 748Heat recovery capacity (3) kW 205 255 291 344 393 459 514 589 686 738 831 941Total power input (3) kW 45,7 57 65,9 76,3 86,9 103 117 128 149 158 180 205TER (4) - 8,03 8,00 7,89 8,07 8,10 7,97 7,85 8,26 8,28 8,40 8,29 8,24COMPRESSORSNo. Compressors/No. Circuits N. 2 / 2 2 / 2 2 / 2 2 / 2 2 / 2 2 / 2 2 / 2 2 / 2 2 / 2 2 / 2 2 / 2 2 / 2NOISE LEVELSTotal power input kWSound power (5) dB(A) 94 95 97 97 97 97 97 98 99 99 99 99Sound pressure (6) dB(A) 76 77 79 79 79 79 78 79 80 80 80 80SIZEA (7) mm 3680 3680 3680 3680 3680 3680 3800 3800 3800 5000 5000 5000B (7) mm 1170 1170 1170 1170 1170 1170 1490 1490 1490 1490 1490 1490H (7) mm 1950 1950 1950 1950 1950 1950 1950 1950 1950 2050 2050 2050Operating weight (7) kg * * * * * * * * * * * *

SYSTEM

4 PIPE

r HFCR-134a

SCREWSHELL & TUBES

Page 220: Products Guide V01 - ParagonEfficient project management thanks to Climaveneta as unique project leader. Complete and specialized Organization Climaveneta qualifies itself for the

218

ERRONIC TEEN

Page 221: Products Guide V01 - ParagonEfficient project management thanks to Climaveneta as unique project leader. Complete and specialized Organization Climaveneta qualifies itself for the

219

RMINALShydronic terminals

hyd

ron

icte

rmin

als

Page 222: Products Guide V01 - ParagonEfficient project management thanks to Climaveneta as unique project leader. Complete and specialized Organization Climaveneta qualifies itself for the

220

Main accessoriesHot water coil kit 1 row and 2 rows

Kit RS485 - interface for Building Management System

Kit control board to manage 0-10V or 3 points modulating valve unit Main coil valve unit ON/OFF, 0-10 V, 3 points 2-way or 3-wayAdditional coil valve unit ON/OFF, PWM, 0-10 V, 3 points 3-way or 2-way

Kit LIFE BOX

Straight and angular (90°) plenum kits for air inlet

Straight and angular (90°) plenum kits for air outlet

Plenum kit with round air ducts for plenum kit

Electric heaters

FeaturesLow noise centrifugal fan, with double intake and forward blade;Four pipe system: 3+2 and 4+1 (number of rows for main + additional coil);

6-speed autotransformer;

Air filter on all models;

Cabinet in galvanised steel with prevarnished finish for maximum resistance to rust;Automatically closing flap to cover and protect electric controls from dripping water (in conformity with directive 60335-2-40);

VersionsDFI built-in version, front air intake

DFU version with cabinet, front air intake

DLI built-in version, bottom air intake

DLU version with cabinet, bottom air intake

CommandsNS plug-in/NSW wall mountedFan speed slider, mode slider (OFF/summer/winter). ON/OFF valve unit control (summer/winter for 2 pipes installation), ON/OFF second valve unit control (winter for 4 pipes installation). Setting for minimum temperature thermostat.

PS plug-in/PSW wall mountedFan speed slider, mode slider (OFF/summer/winter). ON/OFF valve unit control (summer/winter for 2 pipes installation), ON/OFF second valve unit control (winter for 4 pipes installation). Remote water temperature probe.

MT plug-in/MTW wall mountedFan speed slider, mode slider (OFF/summer/winter). Thermostat with set point regulation. ON/OFF valve unit control (summer/winter for 2 pipes installation), ON/OFF second valve unit control (winter for 4 pipes installation). Room temperature probe. Remote water temperature probe.

AT plug-in/ATW wall mountedMode button (OFF/summer/winter/AUTO), fan speed button (Max/Med/Min/AUTO). Thermostat with set point regulation. ON/OFF valve unit control (summer/winter for 2 pipes installation), ON/OFF second valve unit control (winter for 4 pipes installation). Control of traditional or PWM modulating valve units. Room temperature probe and water temperature probe. Digital input configurable as: window contact, economy, heating or cooling remote changeover, periodic ventilation. Configuration dip switch. TTL serial port with Modbus protocol for installation in Building Management System.

Hydronic terminals

a-LIFE 120÷840

Fan-coil for professional applications, with cabinet or built-in version

1,45 - 11,9 kWUnit Descriptiona-LIFE fan-coil has been specifically developed to adapt to every ambient thanks to its modern and minimal design, which is a result of the full experience and know-how Climaveneta has in this range of products.

Page 223: Products Guide V01 - ParagonEfficient project management thanks to Climaveneta as unique project leader. Complete and specialized Organization Climaveneta qualifies itself for the

221

a-LIFE / DLUModels 120 130 140 220 230 240 320 330 340 420 430Air flow rateSpeed 1 m3/h 430 410 390 500 480 450 510 485 460 830 815Speed 2 m3/h 390 360 340 430 410 380 440 415 390 700 680Speed 3 m3/h 330 315 290 365 350 320 375 355 330 580 565Speed 4 m3/h 290 270 250 310 300 270 320 305 280 480 470Speed 5 m3/h 220 200 180 240 225 210 250 230 220 330 315Speed 6 m3/h 180 175 160 210 200 180 220 205 190 280 270Total output cooling capacity (1)Speed 1 (1) kW 1,45 1,91 2,32 2,13 2,67 3,20 2,76 3,22 3,68 3,77 4,69Speed 2 (1) kW 1,37 1,75 2,10 1,93 2,37 2,81 2,49 2,86 3,23 3,39 4,14Speed 3 (1) kW 1,24 1,59 1,87 1,72 2,10 2,46 2,23 2,53 2,79 3 3,62Speed 4 (1) kW 1,14 1,42 1,67 1,53 1,85 2,13 1,99 2,24 2,42 2,64 3,16Speed 5 (1) kW 0,96 1,11 1,27 1,26 1,42 1,71 1,65 1,77 1,97 2,02 2,31Speed 6 (1) kW 0,84 0,97 1,16 1,13 1,23 1,48 1,49 1,59 1,64 1,79 2,03Sensible output cooling capacity (1)Speed 1 (1) kW 1,36 1,63 1,77 1,89 2,17 2,41 2,26 2,47 2,68 3,25 3,77Speed 2 (1) kW 1,27 1,47 1,58 1,68 1,91 2,09 2,01 2,17 2,34 2,86 3,27Speed 3 (1) kW 1,13 1,32 1,39 1,48 1,67 1,82 1,77 1,90 2,01 2,48 2,82Speed 4 (1) kW 1,03 1,16 1,23 1,30 1,46 1,56 1,56 1,67 1,73 2,15 2,42Speed 5 (1) kW 0,83 0,89 0,93 1,04 1,11 1,24 1,27 1,30 1,40 1,59 1,72Speed 6 (1) kW 0,71 0,78 0,84 0,93 0,97 1,07 1,14 1,17 1,18 1,39 1,50Max Water flow (1) l/h 250 330 400 370 460 550 470 550 630 650 800Max Pressure drop (1) kPa 12 5 10 6 5 8 11 7 5 19 14Total output heating capacity (2)Speed 1 (2) kW 3,25 4,46 5,01 4,77 5,79 6,28 5,40 6,36 6,76 7,68 9,58Speed 2 (2) kW 3,04 4,04 4,49 4,28 5,12 5,44 4,84 5,60 5,85 6,81 8,33Speed 3 (2) kW 2,72 3,66 3,94 3,79 4,51 4,70 4,28 4,92 5,05 5,94 7,19Speed 4 (2) kW 2,49 3,25 3,49 3,36 3,98 4,05 3,79 4,33 4,36 5,16 6,20Speed 5 (2) kW 2,05 2,56 2,64 2,76 3,13 3,24 3,11 3,39 3,50 3,88 4,45Speed 6 (2) kW 1,77 2,30 2,38 2,49 2,83 2,82 2,81 3,07 3,05 3,41 3,90Max Water flow (2) l/h 350 390 440 420 510 550 470 560 590 670 840Max Pressure drop (2) kPa 10 5 8 5 4 7 9 6 5 16 12Total output heating capacity (3)Speed 1 (3) kW 1,98 2,71 3,04 2,91 3,52 3,80 3,29 3,86 4,09 4,69 5,83Speed 2 (3) kW 1,86 2,46 2,72 2,61 3,11 3,30 2,94 3,40 3,54 4,15 5,06Speed 3 (3) kW 1,66 2,22 2,39 2,31 2,74 2,84 2,60 2,98 3,05 3,62 4,37Speed 4 (3) kW 1,52 1,97 2,11 2,04 2,41 2,45 2,30 2,62 2,63 3,14 3,76Speed 5 (3) kW 1,25 1,55 1,60 1,68 1,90 1,96 1,89 2,05 2,09 2,36 2,69Speed 6 (3) kW 1,08 1,39 1,44 1,51 1,72 1,70 1,71 1,85 1,80 2,07 2,36Water flow Max (3) l/h 350 470 530 510 610 660 570 670 710 820 1020Pressure drop Max (3) kPa 11 5 8 5 5 7 10 6 5 17 13Output supplementary coil (2)Speed 1 (2) kW 1,48 1,48 - 2,12 2,12 - 2,48 2,48 - 3,48 3,48Speed 2 (2) kW 1,37 1,37 - 1,92 1,92 - 2,24 2,24 - 3,13 3,13Speed 3 (2) kW 1,26 1,26 - 1,74 1,74 - 2,02 2,02 - 2,78 2,78Speed 4 (2) kW 1,15 1,15 - 1,57 1,57 - 1,82 1,82 - 2,46 2,46Speed 5 (2) kW 0,95 0,95 - 1,30 1,30 - 1,50 1,50 - 1,92 1,92Speed 6 (2) kW 0,87 0,87 - 1,20 1,20 - 1,39 1,39 - 1,72 1,72Water flow Max (2) l/h 130 130 - 190 190 - 220 220 - 310 310Pressure drop Max (2) kPa 2 2 - 4 4 - 7 7 - 13 13Sound pressure level (4)Speed 1 (4) dB(A) 46 46 47 48 48 49 48 48 49 51 51Speed 2 (4) dB(A) 41 41 42 44 44 45 44 44 45 47 47Speed 3 (4) dB(A) 38 38 39 40 40 41 40 40 41 43 43Speed 4 (4) dB(A) 35 35 36 37 37 38 37 37 38 41 41Speed 5 (4) dB(A) 30 30 31 30 30 31 31 31 32 33 33Speed 6 (4) dB(A) 28 28 29 29 29 30 29 29 30 30 30Water content l 0,50 0,70 0,70 0,70 1 1 1 1,40 1,40 1 1,40Fan 1 C 1 C 1 C 1 C 1 C 1 C 1 C 1 C 1 C 2 C 2 CWater IN connection inch 1/2”G F 1/2”G F 1/2”G F 1/2”G F 1/2”G F 1/2”G F 1/2”G F 1/2”G F 1/2”G F 1/2”G F 1/2”G FWater OUT connection inchMax absorbed power W 66 66 66 77 77 77 93 93 93 130 130Max absorbed current A 0,29 0,29 0,29 0,30 0,30 0,30 0,41 0,41 0,41 0,57 0,57Electrical power supply V-Ph~Hz 230-1-50 230-1-50 230-1-50 230-1-50 230-1-50 230-1-50 230-1-50 230-1-50 230-1-50 230-1-50 230-1-50DIMENSIONWith Cabinet L (mm) 732 732 732 922 922 922 1112 1112 1112 1112 1112H (mm) 541 541 541 541 541 541 541 541 541 541 541P (mm) 233 233 233 233 233 233 233 233 233 233 233Weight kg 18 18 18 22 22 22 26 26 26 28 28

2 PIPES4 PIPESCENTRIFUGALFAN COILCONTROLLER

Page 224: Products Guide V01 - ParagonEfficient project management thanks to Climaveneta as unique project leader. Complete and specialized Organization Climaveneta qualifies itself for the

222

Note:

1 Operation in cooling mode: room temperature 27°C d.b./19°C w.b., chilled water at inlet 7°C and at outlet 12°C

2 Operation in heating mode: room temperature 20°C d.b., hot water at inlet 70°C and at outlet 60°C

3 Operation in heating mode: room temperature 20°C d.b., hot water at inlet 50°C, with identical flow rate that in the cooling mode

4 Sound pressure in semianechoic room at 1 m from fan front and 1 m from the ground

Models 440 520 530 540 620 630 640 720 730 740Air flow rateSpeed 1 m3/h 790 950 915 880 940 925 900 1360 1310 1260Speed 2 m3/h 660 815 780 750 810 790 770 1150 1090 1070Speed 3 m3/h 454 710 680 655 710 685 670 970 920 880Speed 4 m3/h 455 610 585 560 600 590 560 790 740 700Speed 5 m3/h 300 460 440 420 460 445 440 640 590 570Speed 6 m3/h 260 400 390 380 410 400 390 480 440 430Total output cooling capacity (1)Speed 1 (1) kW 5,57 4,66 5,75 6,54 5,18 6,92 7,47 6,59 8,94 9,64Speed 2 (1) kW 4,87 4,21 5,13 5,80 4,68 6,16 6,57 5,92 7,81 8,54Speed 3 (1) kW 4,22 3,84 4,65 5,26 4,26 5,53 5,84 5,29 6,89 7,30Speed 4 (1) kW 3,65 3,45 4,15 4,63 3,77 4,88 5,08 4,60 5,87 6,02Speed 5 (1) kW 2,56 2,81 3,36 3,66 3,09 3,90 4,14 3,96 4,88 5,13Speed 6 (1) kW 2,28 2,52 3,05 3,38 2,83 3,58 3,71 3,20 3,87 4,03Sensible output cooling capacity (1)Speed 1 (1) kW 4,20 3,95 4,50 4,86 4,23 5,13 5,40 5,61 6,81 7,12Speed 2 (1) kW 3,62 3,51 3,96 4,27 3,76 4,52 4,72 4,94 5,86 6,24Speed 3 (1) kW 3,10 3,15 3,54 3,84 3,38 4,03 4,17 4,33 5,11 5,28Speed 4 (1) kW 2,66 2,79 3,12 3,35 2,95 3,53 3,59 3,68 4,30 4,31Speed 5 (1) kW 1,84 2,22 2,48 2,61 2,37 2,78 2,82 3,11 3,53 3,63Speed 6 (1) kW 1,63 1,97 2,24 2,40 2,15 2,54 2,50 2,45 2,75 2,82Max Water flow (1) l/h 960 800 990 1120 890 1190 1280 1130 1530 1650Max Pressure drop (1) kPa 11 11 22 18 16 18 14 24 27 23Total output heating capacity (2)Speed 1 (2) kW 10,7 9,92 11,2 12,3 10,8 13,1 13,5 13,7 17,4 18Speed 2 (2) kW 9,18 8,86 9,88 10,7 9,61 11,4 11,8 12,2 15 15,7Speed 3 (2) kW 7,81 7,98 8,85 9,56 8,68 10,1 10,4 10,7 13 13,3Speed 4 (2) kW 6,69 7,11 7,83 8,34 7,61 8,88 8,85 9,16 10,8 10,8Speed 5 (2) kW 4,63 5,70 6,18 6,47 6,15 6,91 7,09 7,78 8,88 8,99Speed 6 (2) kW 4,07 5,09 5,58 5,91 5,59 6,28 6,33 6,18 6,84 6,94Max Water flow (2) l/h 930 870 980 1080 950 1150 1190 1210 1530 1580Max Pressure drop (2) kPa 10 10 19 15 14 11 12 21 22 19Total output heating capacity (3)Speed 1 (3) kW 6,46 6,04 6,81 7,44 6,67 7,93 8,25 8,37 10,6 11Speed 2 (3) kW 5,57 5,39 6 6,50 5,93 6,93 7,19 7,40 9,10 9,55Speed 3 (3) kW 4,73 4,86 5,37 5,79 5,33 6,12 6,35 6,52 7,89 8,05Speed 4 (3) kW 4,05 4,32 4,75 5,05 4,73 5,37 5,33 5,57 6,55 6,57Speed 5 (3) kW 2,80 3,46 3,75 3,91 3,77 4,18 4,19 4,73 5,37 5,42Speed 6 (3) kW 2,46 3,09 3,38 3,57 3,36 3,79 3,72 3,75 4,13 4,10Water flow Max (3) l/h 1130 1050 1190 1300 1160 1380 1440 1460 1850 1920Pressure drop Max (3) kPa 10 10 20 16 14 16 12 22 24 21Output supplementary coil (2)Speed 1 (2) kW - 4,11 4,11 - 4,52 4,52 - 5,62 5,62 -Speed 2 (2) kW - 3,71 3,71 - 4,09 4,09 - 5,02 5,02 -Speed 3 (2) kW - 3,40 3,40 - 3,72 3,72 - 4,51 4,51 -Speed 4 (2) kW - 3,09 3,09 - 3,37 3,37 - 3,92 3,92 -Speed 5 (2) kW - 2,55 2,55 - 2,78 2,78 - 3,37 3,37 -Speed 6 (2) kW - 2,35 2,35 - 2,59 2,59 - 2,76 2,76 -Water flow Max (2) l/h - 360 360 - 400 400 - 490 490 -Pressure drop Max (2) kPa - 20 20 - 24 24 - 35 35 -Sound pressure level (4)Speed 1 (4) dB(A) 52 51 51 52 52 52 53 54 54 55Speed 2 (4) dB(A) 48 47 47 48 48 48 49 49 49 50Speed 3 (4) dB(A) 44 44 44 45 45 45 46 46 46 47Speed 4 (4) dB(A) 42 40 40 42 41 41 42 41 41 42Speed 5 (4) dB(A) 34 33 33 34 35 35 36 36 36 37Speed 6 (4) dB(A) 31 30 30 31 33 33 34 33 33 34Water content l 1 1,20 1,80 1,40 1,50 2,20 2,20 1,50 2,20 2,20Fan 2 C 2 C 2 C 2 C 2 C 2 C 2 C 3 C 3 C 3 CWater IN connection inch 1/2”G F 1/2”G F 1/2”G F 1/2”G F 1/2”G F 1/2”G F 1/2”G F 1/2”G F 1/2”G F 1/2”G FWater OUT connection inchMax absorbed power W 130 150 150 150 165 165 165 245 245 245Max absorbed current A 0,57 0,60 0,60 0,60 0,73 0,73 0,73 1,10 1,10 1,10Electrical power supply V-Ph~Hz 230-1-50 230-1-50 230-1-50 230-1-50 230-1-50 230-1-50 230-1-50 230-1-50 230-1-50 230-1-50DIMENSIONWith Cabinet L (mm) 1112 1302 1302 1302 1492 1492 1492 1492 1492 1492H (mm) 541 541 541 541 541 541 541 541 541 541P (mm) 233 233 233 233 233 233 233 233 233 233Weight kg 28 32 32 32 38 38 38 43 43 43

Page 225: Products Guide V01 - ParagonEfficient project management thanks to Climaveneta as unique project leader. Complete and specialized Organization Climaveneta qualifies itself for the

223

a-LIFE / DFUModels 120 130 140 220 230 240 320 330 340 420 430Air flow rateSpeed 1 m3/h 430 410 390 500 480 450 510 485 460 830 815Speed 2 m3/h 390 360 340 430 410 380 440 415 390 700 680Speed 3 m3/h 330 315 290 365 350 320 375 355 330 580 565Speed 4 m3/h 290 270 250 310 300 270 320 305 280 480 470Speed 5 m3/h 220 200 180 240 225 210 250 230 220 330 315Speed 6 m3/h 180 175 160 210 200 180 220 205 190 280 270Total output cooling capacity (1)Speed 1 (1) kW 1,45 1,91 2,32 2,13 2,67 3,20 2,76 3,22 3,68 3,77 4,69Speed 2 (1) kW 1,37 1,75 2,10 1,93 2,37 2,81 2,49 2,86 3,23 3,39 4,14Speed 3 (1) kW 1,24 1,59 1,87 1,72 2,10 2,46 2,23 2,53 2,79 3 3,62Speed 4 (1) kW 1,14 1,42 1,67 1,53 1,85 2,13 1,99 2,24 2,42 2,64 3,16Speed 5 (1) kW 0,96 1,11 1,27 1,26 1,42 1,71 1,65 1,77 1,97 2,02 2,31Speed 6 (1) kW 0,84 0,97 1,16 1,13 1,23 1,48 1,49 1,59 1,64 1,79 2,03Sensible output cooling capacity (1)Speed 1 (1) kW 1,36 1,63 1,77 1,89 2,17 2,41 2,26 2,47 2,68 3,25 3,77Speed 2 (1) kW 1,27 1,47 1,58 1,68 1,91 2,09 2,01 2,17 2,34 2,86 3,27Speed 3 (1) kW 1,13 1,32 1,39 1,48 1,67 1,82 1,77 1,90 2,01 2,48 2,82Speed 4 (1) kW 1,03 1,16 1,23 1,30 1,46 1,56 1,56 1,67 1,73 2,15 2,42Speed 5 (1) kW 0,83 0,89 0,93 1,04 1,11 1,24 1,27 1,30 1,40 1,59 1,72Speed 6 (1) kW 0,71 0,78 0,84 0,93 0,97 1,07 1,14 1,17 1,18 1,39 1,50Max Water flow (1) l/h 250 330 400 370 460 550 470 550 630 650 800Max Pressure drop (1) kPa 12 5 10 6 5 8 11 7 5 19 14Total output heating capacity (2)Speed 1 (2) kW 3,25 4,46 5,01 4,77 5,79 6,28 5,40 6,36 6,76 7,68 9,58Speed 2 (2) kW 3,04 4,04 4,49 4,28 5,12 5,44 4,84 5,60 5,85 6,81 8,33Speed 3 (2) kW 2,72 3,66 3,94 3,79 4,51 4,70 4,28 4,92 5,05 5,94 7,19Speed 4 (2) kW 2,49 3,25 3,49 3,36 3,98 4,05 3,79 4,33 4,36 5,16 6,20Speed 5 (2) kW 2,05 2,56 2,64 2,76 3,13 3,24 3,11 3,39 3,50 3,88 4,45Speed 6 (2) kW 1,77 2,30 2,38 2,49 2,83 2,82 2,81 3,07 3,05 3,41 3,90Max Water flow (2) l/h 350 390 440 420 510 550 470 560 590 670 840Max Pressure drop (2) kPa 10 5 8 5 4 7 9 6 5 16 12Total output heating capacity (3)Speed 1 (3) kW 1,98 2,71 3,04 2,91 3,52 3,80 3,29 3,86 4,09 4,69 5,83Speed 2 (3) kW 1,86 2,46 2,72 2,61 3,11 3,30 2,94 3,40 3,54 4,15 5,06Speed 3 (3) kW 1,66 2,22 2,39 2,31 2,74 2,84 2,60 2,98 3,05 3,62 4,37Speed 4 (3) kW 1,52 1,97 2,11 2,04 2,41 2,45 2,30 2,62 2,63 3,14 3,76Speed 5 (3) kW 1,25 1,55 1,60 1,68 1,90 1,96 1,89 2,05 2,09 2,36 2,69Speed 6 (3) kW 1,08 1,39 1,44 1,51 1,72 1,70 1,71 1,85 1,80 2,07 2,36Water flow Max (3) l/h 350 470 530 510 610 660 570 670 710 820 1020Pressure drop Max (3) kPa 11 5 8 5 5 7 10 6 5 17 13Output supplementary coil (2)Speed 1 (2) kW 1,48 1,48 - 2,12 2,12 - 2,48 2,48 - 3,48 3,48Speed 2 (2) kW 1,37 1,37 - 1,92 1,92 - 2,24 2,24 - 3,13 3,13Speed 3 (2) kW 1,26 1,26 - 1,74 1,74 - 2,02 2,02 - 2,78 2,78Speed 4 (2) kW 1,15 1,15 - 1,57 1,57 - 1,82 1,82 - 2,46 2,46Speed 5 (2) kW 0,95 0,95 - 1,30 1,30 - 1,50 1,50 - 1,92 1,92Speed 6 (2) kW 0,87 0,87 - 1,20 1,20 - 1,39 1,39 - 1,72 1,72Water flow Max (2) l/h 130 130 - 190 190 - 220 220 - 310 310Pressure drop Max (2) kPa 2 2 - 4 4 - 7 7 - 13 13Sound pressure level (4)Speed 1 (4) dB(A) 46 46 47 48 48 49 48 48 49 51 51Speed 2 (4) dB(A) 41 41 42 44 44 45 44 44 45 47 47Speed 3 (4) dB(A) 38 38 39 40 40 41 40 40 41 43 43Speed 4 (4) dB(A) 35 35 36 37 37 38 37 37 38 41 41Speed 5 (4) dB(A) 30 30 31 30 30 31 31 31 32 33 33Speed 6 (4) dB(A) 28 28 29 29 29 30 29 29 30 30 30Water content l 0,50 0,70 0,70 0,70 1 1 1 1,40 1,40 1 1,40Fan 1 C 1 C 1 C 1 C 1 C 1 C 1 C 1 C 1 C 2 C 2 CWater IN connection inch 1/2”G F 1/2”G F 1/2”G F 1/2”G F 1/2”G F 1/2”G F 1/2”G F 1/2”G F 1/2”G F 1/2”G F 1/2”G FWater OUT connection inchMax absorbed power W 66 66 66 77 77 77 93 93 93 130 130Max absorbed current A 0,29 0,29 0,29 0,30 0,30 0,30 0,41 0,41 0,41 0,57 0,57Electrical power supply V-Ph~Hz 230-1-50 230-1-50 230-1-50 230-1-50 230-1-50 230-1-50 230-1-50 230-1-50 230-1-50 230-1-50 230-1-50DIMENSIONWith Cabinet L (mm) 732 732 732 922 922 922 1112 1112 1112 1112 1112H (mm) 541 541 541 541 541 541 541 541 541 541 541P (5) (mm) 245 245 245 245 245 245 245 245 245 245 245Weight kg 18 18 18 22 22 22 26 26 26 28 28

Page 226: Products Guide V01 - ParagonEfficient project management thanks to Climaveneta as unique project leader. Complete and specialized Organization Climaveneta qualifies itself for the

224

Note:

1 Operation in cooling mode: room temperature 27°C d.b./19°C w.b., chilled water at inlet 7°C and at outlet 12°C

2 Operation in heating mode: room temperature 20°C d.b., hot water at inlet 70°C and at outlet 60°C

3 Operation in heating mode: room temperature 20°C d.b., hot water at inlet 50°C, with identical flow rate that in the cooling mode

4 Sound pressure in semianechoic room at 1 m from fan front and 1 m from the ground

5 Size related to the air inlet grille

Models 440 520 530 540 620 630 640 720 730 740Air flow rateSpeed 1 m3/h 790 950 915 880 940 925 900 1360 1310 1260Speed 2 m3/h 660 815 780 750 810 790 770 1150 1090 1070Speed 3 m3/h 454 710 680 655 710 685 670 970 920 880Speed 4 m3/h 455 610 585 560 600 590 560 790 740 700Speed 5 m3/h 300 460 440 420 460 445 440 640 590 570Speed 6 m3/h 260 400 390 380 410 400 390 480 440 430Total output cooling capacity (1)Speed 1 (1) kW 5,57 4,66 5,75 6,54 5,18 6,92 7,47 6,59 8,94 9,64Speed 2 (1) kW 4,87 4,21 5,13 5,80 4,68 6,16 6,57 5,92 7,81 8,54Speed 3 (1) kW 4,22 3,84 4,65 5,26 4,26 5,53 5,84 5,29 6,89 7,30Speed 4 (1) kW 3,65 3,45 4,15 4,63 3,77 4,88 5,08 4,60 5,87 6,02Speed 5 (1) kW 2,56 2,81 3,36 3,66 3,09 3,90 4,14 3,96 4,88 5,13Speed 6 (1) kW 2,28 2,52 3,05 3,38 2,83 3,58 3,71 3,20 3,87 4,03Sensible output cooling capacity (1)Speed 1 (1) kW 4,20 3,95 4,50 4,86 4,23 5,13 5,40 5,61 6,81 7,12Speed 2 (1) kW 3,62 3,51 3,96 4,27 3,76 4,52 4,72 4,94 5,86 6,24Speed 3 (1) kW 3,10 3,15 3,54 3,84 3,38 4,03 4,17 4,33 5,11 5,28Speed 4 (1) kW 2,66 2,79 3,12 3,35 2,95 3,53 3,59 3,68 4,30 4,31Speed 5 (1) kW 1,84 2,22 2,48 2,61 2,37 2,78 2,82 3,11 3,53 3,63Speed 6 (1) kW 1,63 1,97 2,24 2,40 2,15 2,54 2,50 2,45 2,75 2,82Max Water flow (1) l/h 960 800 990 1120 890 1190 1280 1130 1530 1650Max Pressure drop (1) kPa 11 11 22 18 16 18 14 24 27 23Total output heating capacity (2)Speed 1 (2) kW 10,7 9,92 11,2 12,3 10,8 13,1 13,5 13,7 17,4 18Speed 2 (2) kW 9,18 8,86 9,88 10,7 9,61 11,4 11,8 12,2 15 15,7Speed 3 (2) kW 7,81 7,98 8,85 9,56 8,68 10,1 10,4 10,7 13 13,3Speed 4 (2) kW 6,69 7,11 7,83 8,34 7,61 8,88 8,85 9,16 10,8 10,8Speed 5 (2) kW 4,63 5,70 6,18 6,47 6,15 6,91 7,09 7,78 8,88 8,99Speed 6 (2) kW 4,07 5,09 5,58 5,91 5,59 6,28 6,33 6,18 6,84 6,94Max Water flow (2) l/h 930 870 980 1080 950 1150 1190 1210 1530 1580Max Pressure drop (2) kPa 10 10 19 15 14 11 12 21 22 19Total output heating capacity (3)Speed 1 (3) kW 6,46 6,04 6,81 7,44 6,67 7,93 8,25 8,37 10,6 11Speed 2 (3) kW 5,57 5,39 6 6,50 5,93 6,93 7,19 7,40 9,10 9,55Speed 3 (3) kW 4,73 4,86 5,37 5,79 5,33 6,12 6,35 6,52 7,89 8,05Speed 4 (3) kW 4,05 4,32 4,75 5,05 4,73 5,37 5,33 5,57 6,55 6,57Speed 5 (3) kW 2,80 3,46 3,75 3,91 3,77 4,18 4,19 4,73 5,37 5,42Speed 6 (3) kW 2,46 3,09 3,38 3,57 3,36 3,79 3,72 3,75 4,13 4,10Water flow Max (3) l/h 1130 1050 1190 1300 1160 1380 1440 1460 1850 1920Pressure drop Max (3) kPa 10 10 20 16 14 16 12 22 24 21Output supplementary coil (2)Speed 1 (2) kW - 4,11 4,11 - 4,52 4,52 - 5,62 5,62 -Speed 2 (2) kW - 3,71 3,71 - 4,09 4,09 - 5,02 5,02 -Speed 3 (2) kW - 3,40 3,40 - 3,72 3,72 - 4,51 4,51 -Speed 4 (2) kW - 3,09 3,09 - 3,37 3,37 - 3,92 3,92 -Speed 5 (2) kW - 2,55 2,55 - 2,78 2,78 - 3,37 3,37 -Speed 6 (2) kW - 2,35 2,35 - 2,59 2,59 - 2,76 2,76 -Water flow Max (2) l/h - 360 360 - 400 400 - 490 490 -Pressure drop Max (2) kPa - 20 20 - 24 24 - 35 35 -Sound pressure level (4)Speed 1 (4) dB(A) 52 51 51 52 52 52 53 54 54 55Speed 2 (4) dB(A) 48 47 47 48 48 48 49 49 49 50Speed 3 (4) dB(A) 44 44 44 45 45 45 46 46 46 47Speed 4 (4) dB(A) 42 40 40 42 41 41 42 41 41 42Speed 5 (4) dB(A) 34 33 33 34 35 35 36 36 36 37Speed 6 (4) dB(A) 31 30 30 31 33 33 34 33 33 34Water content l 1 1,20 1,80 1,40 1,50 2,20 2,20 1,50 2,20 2,20Fan 2 C 2 C 2 C 2 C 2 C 2 C 2 C 3 C 3 C 3 CWater IN connection inch 1/2”G F 1/2”G F 1/2”G F 1/2”G F 1/2”G F 1/2”G F 1/2”G F 1/2”G F 1/2”G F 1/2”G FWater OUT connection inchMax absorbed power W 130 150 150 150 165 165 165 245 245 245Max absorbed current A 0,57 0,60 0,60 0,60 0,73 0,73 0,73 1,10 1,10 1,10Electrical power supply V-Ph~Hz 230-1-50 230-1-50 230-1-50 230-1-50 230-1-50 230-1-50 230-1-50 230-1-50 230-1-50 230-1-50DIMENSIONWith Cabinet L (mm) 1112 1302 1302 1302 1492 1492 1492 1492 1492 1492H (mm) 541 541 541 541 541 541 541 541 541 541P (5) (mm) 245 245 245 245 245 245 245 245 245 245Weight kg 28 32 32 32 38 38 38 43 43 43

Page 227: Products Guide V01 - ParagonEfficient project management thanks to Climaveneta as unique project leader. Complete and specialized Organization Climaveneta qualifies itself for the

225

a-LIFE / DLIModels 120 130 140 220 230 240 320 330 340 420 430 440Air flow rateSpeed 1 m3/h 430 410 390 500 480 450 510 485 460 830 815 790Speed 2 m3/h 390 360 340 430 410 380 440 415 390 700 680 660Speed 3 m3/h 330 315 290 365 350 320 375 355 330 580 565 454Speed 4 m3/h 290 270 250 310 300 270 320 305 280 480 470 455Speed 5 m3/h 220 200 180 240 225 210 250 230 220 330 315 300Speed 6 m3/h 180 175 160 210 200 180 220 205 190 280 270 260Total output cooling capacity (1)Speed 1 (1) kW 1,45 1,91 2,32 2,13 2,67 3,20 2,76 3,22 3,68 3,77 4,69 5,57Speed 2 (1) kW 1,37 1,75 2,10 1,93 2,37 2,81 2,49 2,86 3,23 3,39 4,14 4,87Speed 3 (1) kW 1,24 1,59 1,87 1,72 2,10 2,46 2,23 2,53 2,79 3 3,62 4,22Speed 4 (1) kW 1,14 1,42 1,67 1,53 1,85 2,13 1,99 2,24 2,42 2,64 3,16 3,65Speed 5 (1) kW 0,96 1,11 1,27 1,26 1,42 1,71 1,65 1,77 1,97 2,02 2,31 2,56Speed 6 (1) kW 0,84 0,97 1,16 1,13 1,23 1,48 1,49 1,59 1,64 1,79 2,03 2,28Sensible output cooling capacity (1)Speed 1 (1) kW 1,36 1,63 1,77 1,89 2,17 2,41 2,26 2,47 2,68 3,25 3,77 4,20Speed 2 (1) kW 1,27 1,47 1,58 1,68 1,91 2,09 2,01 2,17 2,34 2,86 3,27 3,62Speed 3 (1) kW 1,13 1,32 1,39 1,48 1,67 1,82 1,77 1,90 2,01 2,48 2,82 3,10Speed 4 (1) kW 1,03 1,16 1,23 1,30 1,46 1,56 1,56 1,67 1,73 2,15 2,42 2,66Speed 5 (1) kW 0,83 0,89 0,93 1,04 1,11 1,24 1,27 1,30 1,40 1,59 1,72 1,84Speed 6 (1) kW 0,71 0,78 0,84 0,93 0,97 1,07 1,14 1,17 1,18 1,39 1,50 1,63Max Water flow (1) l/h 250 330 400 370 460 550 470 550 630 650 800 960Max Pressure drop (1) kPa 12 5 10 6 5 8 11 7 5 19 14 11Total output heating capacity (2)Speed 1 (2) kW 3,25 4,46 5,01 4,77 5,79 6,28 5,40 6,36 6,76 7,68 9,58 10,7Speed 2 (2) kW 3,04 4,04 4,49 4,28 5,12 5,44 4,84 5,60 5,85 6,81 8,33 9,18Speed 3 (2) kW 2,72 3,66 3,94 3,79 4,51 4,70 4,28 4,92 5,05 5,94 7,19 7,81Speed 4 (2) kW 2,49 3,25 3,49 3,36 3,98 4,05 3,79 4,33 4,36 5,16 6,20 6,69Speed 5 (2) kW 2,05 2,56 2,64 2,76 3,13 3,24 3,11 3,39 3,50 3,88 4,45 4,63Speed 6 (2) kW 1,77 2,30 2,38 2,49 2,83 2,82 2,81 3,07 3,05 3,41 3,90 4,07Max Water flow (2) l/h 350 390 440 420 510 550 470 560 590 670 840 930Max Pressure drop (2) kPa 10 5 8 5 4 7 9 6 5 16 12 10Total output heating capacity (3)Speed 1 (3) kW 1,98 2,71 3,04 2,91 3,52 3,80 3,29 3,86 4,09 4,69 5,83 6,46Speed 2 (3) kW 1,86 2,46 2,72 2,61 3,11 3,30 2,94 3,40 3,54 4,15 5,06 5,57Speed 3 (3) kW 1,66 2,22 2,39 2,31 2,74 2,84 2,60 2,98 3,05 3,62 4,37 4,73Speed 4 (3) kW 1,52 1,97 2,11 2,04 2,41 2,45 2,30 2,62 2,63 3,14 3,76 4,05Speed 5 (3) kW 1,25 1,55 1,60 1,68 1,90 1,96 1,89 2,05 2,09 2,36 2,69 2,80Speed 6 (3) kW 1,08 1,39 1,44 1,51 1,72 1,70 1,71 1,85 1,80 2,07 2,36 2,46Water flow Max (3) l/h 350 470 530 510 610 660 570 670 710 820 1020 1130Pressure drop Max (3) kPa 11 5 8 5 5 7 10 6 5 17 13 10Output supplementary coil (2)Speed 1 (2) kW 1,48 1,48 - 2,12 2,12 - 2,48 2,48 - 3,48 3,48 -Speed 2 (2) kW 1,37 1,37 - 1,92 1,92 - 2,24 2,24 - 3,13 3,13 -Speed 3 (2) kW 1,26 1,26 - 1,74 1,74 - 2,02 2,02 - 2,78 2,78 -Speed 4 (2) kW 1,15 1,15 - 1,57 1,57 - 1,82 1,82 - 2,46 2,46 -Speed 5 (2) kW 0,95 0,95 - 1,30 1,30 - 1,50 1,50 - 1,92 1,92 -Speed 6 (2) kW 0,87 0,87 - 1,20 1,20 - 1,39 1,39 - 1,72 1,72 -Water flow Max (2) l/h 130 130 - 190 190 - 220 220 - 310 310 -Pressure drop Max (2) kPa 2 2 - 4 4 - 7 7 - 13 13 -Sound pressure level (4)Speed 1 (4) dB(A) 46 46 47 48 48 49 48 48 49 51 51 52Speed 2 (4) dB(A) 41 41 42 44 44 45 44 44 45 47 47 48Speed 3 (4) dB(A) 38 38 39 40 40 41 40 40 41 43 43 44Speed 4 (4) dB(A) 35 35 36 37 37 38 37 37 38 41 41 42Speed 5 (4) dB(A) 30 30 31 30 30 31 31 31 32 33 33 34Speed 6 (4) dB(A) 28 28 29 29 29 30 29 29 30 30 30 31Water content l 0,50 0,70 0,70 0,70 1 1 1 1,40 1,40 1 1,40 1Fan 1 C 1 C 1 C 1 C 1 C 1 C 1 C 1 C 1 C 2 C 2 C 2 CWater IN connection inch 1/2”G F 1/2”G F 1/2”G F 1/2”G F 1/2”G F 1/2”G F 1/2”G F 1/2”G F 1/2”G F 1/2”G F 1/2”G F 1/2”G FWater OUT connection inchMax absorbed power W 66 66 66 77 77 77 93 93 93 130 130 130Max absorbed current A 0,29 0,29 0,29 0,30 0,30 0,30 0,41 0,41 0,41 0,57 0,57 0,57Electrical power supply V-Ph~Hz 230-1-50 230-1-50 230-1-50 230-1-50 230-1-50 230-1-50 230-1-50 230-1-50 230-1-50 230-1-50 230-1-50 230-1-50DIMENSIONBuilt-inL (mm) 411 411 411 601 601 601 791 791 791 791 791 791H (mm) 495 495 495 495 495 495 495 495 495 495 495 495P (mm) 225 225 225 225 225 225 225 225 225 225 225 225Weight kg 12 12 14 15 15 17 18 18 20 20 20 22

Page 228: Products Guide V01 - ParagonEfficient project management thanks to Climaveneta as unique project leader. Complete and specialized Organization Climaveneta qualifies itself for the

226

Note:

1 Operation in cooling mode: room temperature 27°C d.b./19°C w.b., chilled water at inlet 7°C and at outlet 12°C

2 Operation in heating mode: room temperature 20°C d.b., hot water at inlet 70°C and at outlet 60°C

3 Operation in heating mode: room temperature 20°C d.b., hot water at inlet 50°C, with identical flow rate that in the cooling mode

4 Sound pressure in semianechoic room at 1 m from fan front and 1 m from the ground

Models 520 530 540 620 630 640 720 730 740 830 840Air flow rateSpeed 1 m3/h 950 915 880 940 925 900 1360 1310 1260 1620 1580Speed 2 m3/h 815 780 750 810 790 770 1150 1090 1070 1380 1340Speed 3 m3/h 710 680 655 710 685 670 970 920 880 1165 1120Speed 4 m3/h 610 585 560 600 590 560 790 740 700 930 880Speed 5 m3/h 460 440 420 460 445 440 640 590 570 720 690Speed 6 m3/h 400 390 380 410 400 390 480 440 430 520 480Total output cooling capacity (1)Speed 1 (1) kW 4,66 5,75 6,54 5,18 6,92 7,47 6,59 8,94 9,64 10,2 11,9Speed 2 (1) kW 4,21 5,13 5,80 4,68 6,16 6,57 5,92 7,81 8,54 9,11 10,5Speed 3 (1) kW 3,84 4,65 5,26 4,26 5,53 5,84 5,29 6,89 7,30 8,05 9,16Speed 4 (1) kW 3,45 4,15 4,63 3,77 4,88 5,08 4,60 5,87 6,02 6,80 7,50Speed 5 (1) kW 2,81 3,36 3,66 3,09 3,90 4,14 3,96 4,88 5,13 5,59 6,17Speed 6 (1) kW 2,52 3,05 3,38 2,83 3,58 3,71 3,20 3,87 4,03 4,29 4,52Sensible output cooling capacity (1)Speed 1 (1) kW 3,95 4,50 4,86 4,23 5,13 5,40 5,61 6,81 7,12 7,97 8,82Speed 2 (1) kW 3,51 3,96 4,27 3,76 4,52 4,72 4,94 5,86 6,24 7,01 7,71Speed 3 (1) kW 3,15 3,54 3,84 3,38 4,03 4,17 4,33 5,11 5,28 6,11 6,65Speed 4 (1) kW 2,79 3,12 3,35 2,95 3,53 3,59 3,68 4,30 4,31 5,07 5,38Speed 5 (1) kW 2,22 2,48 2,61 2,37 2,78 2,82 3,11 3,53 3,63 4,11 4,37Speed 6 (1) kW 1,97 2,24 2,40 2,15 2,54 2,50 2,45 2,75 2,82 3,11 3,07Max Water flow (1) l/h 800 990 1120 890 1190 1280 1130 1530 1650 1750 2040Max Pressure drop (1) kPa 11 22 18 16 18 14 24 27 23 24 22Total output heating capacity (2)Speed 1 (2) kW 9,92 11,2 12,3 10,8 13,1 13,5 13,7 17,4 18 20,3 22,4Speed 2 (2) kW 8,86 9,88 10,7 9,61 11,4 11,8 12,2 15 15,7 17,9 19,5Speed 3 (2) kW 7,98 8,85 9,56 8,68 10,1 10,4 10,7 13 13,3 15,6 16,7Speed 4 (2) kW 7,11 7,83 8,34 7,61 8,88 8,85 9,16 10,8 10,8 13 13,5Speed 5 (2) kW 5,70 6,18 6,47 6,15 6,91 7,09 7,78 8,88 8,99 10,4 10,9Speed 6 (2) kW 5,09 5,58 5,91 5,59 6,28 6,33 6,18 6,84 6,94 7,85 7,78Max Water flow (2) l/h 870 980 1080 950 1150 1190 1210 1530 1580 1780 1970Max Pressure drop (2) kPa 10 19 15 14 11 12 21 22 19 20 19Total output heating capacity (3)Speed 1 (3) kW 6,04 6,81 7,44 6,67 7,93 8,25 8,37 10,6 11 12,4 13,7Speed 2 (3) kW 5,39 6 6,50 5,93 6,93 7,19 7,40 9,10 9,55 10,9 11,9Speed 3 (3) kW 4,86 5,37 5,79 5,33 6,12 6,35 6,52 7,89 8,05 9,47 10,2Speed 4 (3) kW 4,32 4,75 5,05 4,73 5,37 5,33 5,57 6,55 6,57 7,85 8,21Speed 5 (3) kW 3,46 3,75 3,91 3,77 4,18 4,19 4,73 5,37 5,42 6,31 6,57Speed 6 (3) kW 3,09 3,38 3,57 3,36 3,79 3,72 3,75 4,13 4,10 4,75 4,57Water flow Max (3) l/h 1050 1190 1300 1160 1380 1440 1460 1850 1920 2160 2380Pressure drop Max (3) kPa 10 20 16 14 16 12 22 24 21 22 20Output supplementary coil (2)Speed 1 (2) kW 4,11 4,11 - 4,52 4,52 - 5,62 5,62 - 6,70 -Speed 2 (2) kW 3,71 3,71 - 4,09 4,09 - 5,02 5,02 - 6,07 -Speed 3 (2) kW 3,40 3,40 - 3,72 3,72 - 4,51 4,51 - 5,46 -Speed 4 (2) kW 3,09 3,09 - 3,37 3,37 - 3,92 3,92 - 4,73 -Speed 5 (2) kW 2,55 2,55 - 2,78 2,78 - 3,37 3,37 - 4 -Speed 6 (2) kW 2,35 2,35 - 2,59 2,59 - 2,76 2,76 - 3,21 -Water flow Max (2) l/h 360 360 - 400 400 - 490 490 - 590 -Pressure drop Max (2) kPa 20 20 - 24 24 - 35 35 - 10 -Sound pressure level (4)Speed 1 (4) dB(A) 51 51 52 52 52 53 54 54 55 57 58Speed 2 (4) dB(A) 47 47 48 48 48 49 49 49 50 53 54Speed 3 (4) dB(A) 44 44 45 45 45 46 46 46 47 49 50Speed 4 (4) dB(A) 40 40 42 41 41 42 41 41 42 43 44Speed 5 (4) dB(A) 33 33 34 35 35 36 36 36 37 38 39Speed 6 (4) dB(A) 30 30 31 33 33 34 33 33 34 31 32Water content l 1,20 1,80 1,40 1,50 2,20 2,20 1,50 2,20 2,20 1,70 2,60Fan 2 C 2 C 2 C 2 C 2 C 2 C 3 C 3 C 3 C 4 C 4 CWater IN connection inch 1/2”G F 1/2”G F 1/2”G F 1/2”G F 1/2”G F 1/2”G F 1/2”G F 1/2”G F 1/2”G F 1/2”G F 1/2”G FWater OUT connection inchMax absorbed power W 150 150 150 165 165 165 245 245 245 272 272Max absorbed current A 0,60 0,60 0,60 0,73 0,73 0,73 1,10 1,10 1,10 1,03 1,03Electrical power supply V-Ph~Hz 230-1-50 230-1-50 230-1-50 230-1-50 230-1-50 230-1-50 230-1-50 230-1-50 230-1-50 230-1-50 230-1-50DIMENSIONBuilt-inL (mm) 981 981 981 1171 1171 1171 1171 1171 1171 1361 1361H (mm) 495 495 495 495 495 495 495 495 495 495 495P (mm) 225 225 225 225 225 225 225 225 225 225 225Weight kg 23 23 25 27 27 29 31 31 33 38 38

Page 229: Products Guide V01 - ParagonEfficient project management thanks to Climaveneta as unique project leader. Complete and specialized Organization Climaveneta qualifies itself for the

227

a-LIFE / DFIModels 120 130 140 220 230 240 320 330 340 420 430 440Air flow rateSpeed 1 m3/h 430 410 390 500 480 450 510 485 460 830 815 790Speed 2 m3/h 390 360 340 430 410 380 440 415 390 700 680 660Speed 3 m3/h 330 315 290 365 350 320 375 355 330 580 565 454Speed 4 m3/h 290 270 250 310 300 270 320 305 280 480 470 455Speed 5 m3/h 220 200 180 240 225 210 250 230 220 330 315 300Speed 6 m3/h 180 175 160 210 200 180 220 205 190 280 270 260Total output cooling capacity (1)Speed 1 (1) kW 1,45 1,91 2,32 2,13 2,67 3,20 2,76 3,22 3,68 3,77 4,69 5,57Speed 2 (1) kW 1,37 1,75 2,10 1,93 2,37 2,81 2,49 2,86 3,23 3,39 4,14 4,87Speed 3 (1) kW 1,24 1,59 1,87 1,72 2,10 2,46 2,23 2,53 2,79 3 3,62 4,22Speed 4 (1) kW 1,14 1,42 1,67 1,53 1,85 2,13 1,99 2,24 2,42 2,64 3,16 3,65Speed 5 (1) kW 0,96 1,11 1,27 1,26 1,42 1,71 1,65 1,77 1,97 2,02 2,31 2,56Speed 6 (1) kW 0,84 0,97 1,16 1,13 1,23 1,48 1,49 1,59 1,64 1,79 2,03 2,28Sensible output cooling capacity (1)Speed 1 (1) kW 1,36 1,63 1,77 1,89 2,17 2,41 2,26 2,47 2,68 3,25 3,77 4,20Speed 2 (1) kW 1,27 1,47 1,58 1,68 1,91 2,09 2,01 2,17 2,34 2,86 3,27 3,62Speed 3 (1) kW 1,13 1,32 1,39 1,48 1,67 1,82 1,77 1,90 2,01 2,48 2,82 3,10Speed 4 (1) kW 1,03 1,16 1,23 1,30 1,46 1,56 1,56 1,67 1,73 2,15 2,42 2,66Speed 5 (1) kW 0,83 0,89 0,93 1,04 1,11 1,24 1,27 1,30 1,40 1,59 1,72 1,84Speed 6 (1) kW 0,71 0,78 0,84 0,93 0,97 1,07 1,14 1,17 1,18 1,39 1,50 1,63Max Water flow (1) l/h 250 330 400 370 460 550 470 550 630 650 800 960Max Pressure drop (1) kPa 12 5 10 6 5 8 11 7 5 19 14 11Total output heating capacity (2)Speed 1 (2) kW 3,25 4,46 5,01 4,77 5,79 6,28 5,40 6,36 6,76 7,68 9,58 10,7Speed 2 (2) kW 3,04 4,04 4,49 4,28 5,12 5,44 4,84 5,60 5,85 6,81 8,33 9,18Speed 3 (2) kW 2,72 3,66 3,94 3,79 4,51 4,70 4,28 4,92 5,05 5,94 7,19 7,81Speed 4 (2) kW 2,49 3,25 3,49 3,36 3,98 4,05 3,79 4,33 4,36 5,16 6,20 6,69Speed 5 (2) kW 2,05 2,56 2,64 2,76 3,13 3,24 3,11 3,39 3,50 3,88 4,45 4,63Speed 6 (2) kW 1,77 2,30 2,38 2,49 2,83 2,82 2,81 3,07 3,05 3,41 3,90 4,07Max Water flow (2) l/h 350 390 440 420 510 550 470 560 590 670 840 930Max Pressure drop (2) kPa 10 5 8 5 4 7 9 6 5 16 12 10Total output heating capacity (3)Speed 1 (3) kW 1,98 2,71 3,04 2,91 3,52 3,80 3,29 3,86 4,09 4,69 5,83 6,46Speed 2 (3) kW 1,86 2,46 2,72 2,61 3,11 3,30 2,94 3,40 3,54 4,15 5,06 5,57Speed 3 (3) kW 1,66 2,22 2,39 2,31 2,74 2,84 2,60 2,98 3,05 3,62 4,37 4,73Speed 4 (3) kW 1,52 1,97 2,11 2,04 2,41 2,45 2,30 2,62 2,63 3,14 3,76 4,05Speed 5 (3) kW 1,25 1,55 1,60 1,68 1,90 1,96 1,89 2,05 2,09 2,36 2,69 2,80Speed 6 (3) kW 1,08 1,39 1,44 1,51 1,72 1,70 1,71 1,85 1,80 2,07 2,36 2,46Water flow Max (3) l/h 350 470 530 510 610 660 570 670 710 820 1020 1130Pressure drop Max (3) kPa 11 5 8 5 5 7 10 6 5 17 13 10Output supplementary coil (2)Speed 1 (2) kW 1,48 1,48 - 2,12 2,12 - 2,48 2,48 - 3,48 3,48 -Speed 2 (2) kW 1,37 1,37 - 1,92 1,92 - 2,24 2,24 - 3,13 3,13 -Speed 3 (2) kW 1,26 1,26 - 1,74 1,74 - 2,02 2,02 - 2,78 2,78 -Speed 4 (2) kW 1,15 1,15 - 1,57 1,57 - 1,82 1,82 - 2,46 2,46 -Speed 5 (2) kW 0,95 0,95 - 1,30 1,30 - 1,50 1,50 - 1,92 1,92 -Speed 6 (2) kW 0,87 0,87 - 1,20 1,20 - 1,39 1,39 - 1,72 1,72 -Water flow Max (2) l/h 130 130 - 190 190 - 220 220 - 310 310 -Pressure drop Max (2) kPa 2 2 - 4 4 - 7 7 - 13 13 -Sound pressure level (4)Speed 1 (4) dB(A) 46 46 47 48 48 49 48 48 49 51 51 52Speed 2 (4) dB(A) 41 41 42 44 44 45 44 44 45 47 47 48Speed 3 (4) dB(A) 38 38 39 40 40 41 40 40 41 43 43 44Speed 4 (4) dB(A) 35 35 36 37 37 38 37 37 38 41 41 42Speed 5 (4) dB(A) 30 30 31 30 30 31 31 31 32 33 33 34Speed 6 (4) dB(A) 28 28 29 29 29 30 29 29 30 30 30 31Water content l 0,50 0,70 0,70 0,70 1 1 1 1,40 1,40 1 1,40 1Fan 1 C 1 C 1 C 1 C 1 C 1 C 1 C 1 C 1 C 2 C 2 C 2 CWater IN connection inch 1/2”G F 1/2”G F 1/2”G F 1/2”G F 1/2”G F 1/2”G F 1/2”G F 1/2”G F 1/2”G F 1/2”G F 1/2”G F 1/2”G FWater OUT connection inchMax absorbed power W 66 66 66 77 77 77 93 93 93 130 130 130Max absorbed current A 0,29 0,29 0,29 0,30 0,30 0,30 0,41 0,41 0,41 0,57 0,57 0,57Electrical power supply V-Ph~Hz 230-1-50 230-1-50 230-1-50 230-1-50 230-1-50 230-1-50 230-1-50 230-1-50 230-1-50 230-1-50 230-1-50 230-1-50DIMENSIONBuilt-inL (mm) 411 411 411 601 601 601 791 791 791 791 791 791H (mm) 495 495 495 495 495 495 495 495 495 495 495 495P (mm) 225 225 225 225 225 225 225 225 225 225 225 225Weight kg 12 12 14 15 15 17 18 18 20 20 20 22

Page 230: Products Guide V01 - ParagonEfficient project management thanks to Climaveneta as unique project leader. Complete and specialized Organization Climaveneta qualifies itself for the

228

Note:

1 Operation in cooling mode: room temperature 27°C d.b./19°C w.b., chilled water at inlet 7°C and at outlet 12°C

2 Operation in heating mode: room temperature 20°C d.b., hot water at inlet 70°C and at outlet 60°C

3 Operation in heating mode: room temperature 20°C d.b., hot water at inlet 50°C, with identical flow rate that in the cooling mode

4 Sound pressure in semianechoic room at 1 m from fan front and 1 m from the ground

Models 520 530 540 620 630 640 720 730 740 830 840Air flow rateSpeed 1 m3/h 950 915 880 940 925 900 1360 1310 1260 1620 1580Speed 2 m3/h 815 780 750 810 790 770 1150 1090 1070 1380 1340Speed 3 m3/h 710 680 655 710 685 670 970 920 880 1165 1120Speed 4 m3/h 610 585 560 600 590 560 790 740 700 930 880Speed 5 m3/h 460 440 420 460 445 440 640 590 570 720 690Speed 6 m3/h 400 390 380 410 400 390 480 440 430 520 480Total output cooling capacity (1)Speed 1 (1) kW 4,66 5,75 6,54 5,18 6,92 7,47 6,59 8,94 9,64 10,2 11,9Speed 2 (1) kW 4,21 5,13 5,80 4,68 6,16 6,57 5,92 7,81 8,54 9,11 10,5Speed 3 (1) kW 3,84 4,65 5,26 4,26 5,53 5,84 5,29 6,89 7,30 8,05 9,16Speed 4 (1) kW 3,45 4,15 4,63 3,77 4,88 5,08 4,60 5,87 6,02 6,80 7,50Speed 5 (1) kW 2,81 3,36 3,66 3,09 3,90 4,14 3,96 4,88 5,13 5,59 6,17Speed 6 (1) kW 2,52 3,05 3,38 2,83 3,58 3,71 3,20 3,87 4,03 4,29 4,52Sensible output cooling capacity (1)Speed 1 (1) kW 3,95 4,50 4,86 4,23 5,13 5,40 5,61 6,81 7,12 7,97 8,82Speed 2 (1) kW 3,51 3,96 4,27 3,76 4,52 4,72 4,94 5,86 6,24 7,01 7,71Speed 3 (1) kW 3,15 3,54 3,84 3,38 4,03 4,17 4,33 5,11 5,28 6,11 6,65Speed 4 (1) kW 2,79 3,12 3,35 2,95 3,53 3,59 3,68 4,30 4,31 5,07 5,38Speed 5 (1) kW 2,22 2,48 2,61 2,37 2,78 2,82 3,11 3,53 3,63 4,11 4,37Speed 6 (1) kW 1,97 2,24 2,40 2,15 2,54 2,50 2,45 2,75 2,82 3,11 3,07Max Water flow (1) l/h 800 990 1120 890 1190 1280 1130 1530 1650 1750 2040Max Pressure drop (1) kPa 11 22 18 16 18 14 24 27 23 24 22Total output heating capacity (2)Speed 1 (2) kW 9,92 11,2 12,3 10,8 13,1 13,5 13,7 17,4 18 20,3 22,4Speed 2 (2) kW 8,86 9,88 10,7 9,61 11,4 11,8 12,2 15 15,7 17,9 19,5Speed 3 (2) kW 7,98 8,85 9,56 8,68 10,1 10,4 10,7 13 13,3 15,6 16,7Speed 4 (2) kW 7,11 7,83 8,34 7,61 8,88 8,85 9,16 10,8 10,8 13 13,5Speed 5 (2) kW 5,70 6,18 6,47 6,15 6,91 7,09 7,78 8,88 8,99 10,4 10,9Speed 6 (2) kW 5,09 5,58 5,91 5,59 6,28 6,33 6,18 6,84 6,94 7,85 7,78Max Water flow (2) l/h 870 980 1080 950 1150 1190 1210 1530 1580 1780 1970Max Pressure drop (2) kPa 10 19 15 14 11 12 21 22 19 20 19Total output heating capacity (3)Speed 1 (3) kW 6,04 6,81 7,44 6,67 7,93 8,25 8,37 10,6 11 12,4 13,7Speed 2 (3) kW 5,39 6 6,50 5,93 6,93 7,19 7,40 9,10 9,55 10,9 11,9Speed 3 (3) kW 4,86 5,37 5,79 5,33 6,12 6,35 6,52 7,89 8,05 9,47 10,2Speed 4 (3) kW 4,32 4,75 5,05 4,73 5,37 5,33 5,57 6,55 6,57 7,85 8,21Speed 5 (3) kW 3,46 3,75 3,91 3,77 4,18 4,19 4,73 5,37 5,42 6,31 6,57Speed 6 (3) kW 3,09 3,38 3,57 3,36 3,79 3,72 3,75 4,13 4,10 4,75 4,57Water flow Max (3) l/h 1050 1190 1300 1160 1380 1440 1460 1850 1920 2160 2380Pressure drop Max (3) kPa 10 20 16 14 16 12 22 24 21 22 20Output supplementary coil (2)Speed 1 (2) kW 4,11 4,11 - 4,52 4,52 - 5,62 5,62 - 6,70 -Speed 2 (2) kW 3,71 3,71 - 4,09 4,09 - 5,02 5,02 - 6,07 -Speed 3 (2) kW 3,40 3,40 - 3,72 3,72 - 4,51 4,51 - 5,46 -Speed 4 (2) kW 3,09 3,09 - 3,37 3,37 - 3,92 3,92 - 4,73 -Speed 5 (2) kW 2,55 2,55 - 2,78 2,78 - 3,37 3,37 - 4 -Speed 6 (2) kW 2,35 2,35 - 2,59 2,59 - 2,76 2,76 - 3,21 -Water flow Max (2) l/h 360 360 - 400 400 - 490 490 - 590 -Pressure drop Max (2) kPa 20 20 - 24 24 - 35 35 - 10 -Sound pressure level (4)Speed 1 (4) dB(A) 51 51 52 52 52 53 54 54 55 57 58Speed 2 (4) dB(A) 47 47 48 48 48 49 49 49 50 53 54Speed 3 (4) dB(A) 44 44 45 45 45 46 46 46 47 49 50Speed 4 (4) dB(A) 40 40 42 41 41 42 41 41 42 43 44Speed 5 (4) dB(A) 33 33 34 35 35 36 36 36 37 38 39Speed 6 (4) dB(A) 30 30 31 33 33 34 33 33 34 31 32Water content l 1,20 1,80 1,40 1,50 2,20 2,20 1,50 2,20 2,20 1,70 2,60Fan 2 C 2 C 2 C 2 C 2 C 2 C 3 C 3 C 3 C 4 C 4 CWater IN connection inch 1/2”G F 1/2”G F 1/2”G F 1/2”G F 1/2”G F 1/2”G F 1/2”G F 1/2”G F 1/2”G F 1/2”G F 1/2”G FWater OUT connection inchMax absorbed power W 150 150 150 165 165 165 245 245 245 272 272Max absorbed current A 0,60 0,60 0,60 0,73 0,73 0,73 1,10 1,10 1,10 1,03 1,03Electrical power supply V-Ph~Hz 230-1-50 230-1-50 230-1-50 230-1-50 230-1-50 230-1-50 230-1-50 230-1-50 230-1-50 230-1-50 230-1-50DIMENSIONBuilt-inL (mm) 981 981 981 1171 1171 1171 1171 1171 1171 1361 1361H (mm) 495 495 495 495 495 495 495 495 495 495 495P (mm) 225 225 225 225 225 225 225 225 225 225 225Weight kg 23 23 25 27 27 29 31 31 33 38 38

Page 231: Products Guide V01 - ParagonEfficient project management thanks to Climaveneta as unique project leader. Complete and specialized Organization Climaveneta qualifies itself for the

229

Dimension

P

H

L P

H

L

Page 232: Products Guide V01 - ParagonEfficient project management thanks to Climaveneta as unique project leader. Complete and specialized Organization Climaveneta qualifies itself for the

230

Main accessoriesHot water coil kit 1 row and 2 rows

Kit RS485 - interface for Building Management System

Kit control board to manage 0-10V or 3 points modulating valve unit Main coil valve unit ON/OFF, 0-10 V, 3 points 2-way or 3-wayAdditional coil valve unit ON/OFF, PWM, 0-10 V, 3 points 3-way or 2-way

Straight and angular (90°) plenum kits for air inlet

Straight and angular (90°) plenum kits for air outlet

Plenum kit with round air ducts for plenum kit

Electric heaters

FeaturesFour pipe system: 3+2 and 4+1 (number of rows for main + additional coil);

High pressure centrifugal fan unit for ducted system;

6-speed autotransformer;

Air filter on all models;

Structure in hot galvanised steel for maximum resistance to rust;

VersionsDFI built-in version, front air intake

DLI built-in version, bottom air intake

CommandsNSW wall mountedFan speed slider, mode slider (OFF/summer/winter). ON/OFF valve unit control (summer/winter for 2 pipes installation), ON/OFF second valve unit control (winter for 4 pipes installation). Setting for minimum temperature thermostat.

PSW wall mountedFan speed slider, mode slider (OFF/summer/winter). ON/OFF valve unit control (summer/winter for 2 pipes installation), ON/OFF second valve unit control (winter for 4 pipes installation). Remote water temperature probe.

MTW wall mountedFan speed slider, mode slider (OFF/summer/winter). Thermostat with set point regulation. ON/OFF valve unit control (summer/winter for 2 pipes installation), ON/OFF second valve unit control (winter for 4 pipes installation). Room temperature probe. Remote water temperature probe.

ATW wall mountedMode button (OFF/summer/winter/AUTO), fan speed button (Max/Med/Min/AUTO). Thermostat with set point regulation. ON/OFF valve unit control (summer/winter for 2 pipes installation), ON/OFF second valve unit control (winter for 4 pipes installation). Control of traditional or PWM modulating valve units. Room temperature probe and water temperature probe. Digital input configurable as: window contact, economy, heating or cooling remote changeover, periodic ventilation. Configuration dip switch. TTL serial port with Modbus protocol for installation in Building Management System.

Hydronic terminals

a-LIFE HP 230÷840

High head fan-coil for professional application built-in version

2,83 - 10,9 kWUnit Descriptiona-LIFE HP are professional high-head fan coils by Climaveneta. The enhanced motor and the built-in version make these units ideal for ducted systems in tertiary and commercial sectors.

Page 233: Products Guide V01 - ParagonEfficient project management thanks to Climaveneta as unique project leader. Complete and specialized Organization Climaveneta qualifies itself for the

231

Note:

1 Operation in cooling mode: room temperature 27°C d.b./19°C w.b., chilled water at inlet 7°C and at outlet 12°C

2 Operation in heating mode: room temperature 20°C d.b., hot water at inlet 70°C and at outlet 60°C

3 Operation in heating mode: room temperature 20°C d.b., hot water at inlet 50°C, with identical flow rate that in the cooling mode

4 Sound pressure in semianechoic room at 1 m from fan front and 1 m from the ground

a-LIFE HP / DLIModels 230 240 430 440 530 540 730 740 830 840Air flow rateSpeed 1 m3/h 520 520 600 600 930 930 960 960 1330 1330Speed 2 m3/h 490 490 540 540 800 800 890 890 1260 1260Speed 3 m3/h 460 460 470 470 670 670 810 810 1130 1130Speed 4 m3/h 415 415 405 405 520 520 695 695 940 940Speed 5 m3/h 320 320 290 290 380 380 540 540 720 720Speed 6 m3/h 275 275 250 250 280 280 380 380 520 520Effective static pressure Speed 1 - Max

Pa 40 40 40 40 40 40 40 40 40 40

Total output cooling capacity (1)Speed 1 (1) kW 2,83 3,57 4,04 4,69 5,58 6,54 7,36 8,15 9,95 10,9Speed 2 (1) kW 2,71 3,41 3,74 4,35 5,02 5,90 6,97 7,66 9,56 10,5Speed 3 (1) kW 2,59 3,25 3,37 3,91 4,41 5,15 6,47 7,09 8,83 9,60Speed 4 (1) kW 2,39 3 3,01 3,46 3,64 4,19 5,77 6,23 7,68 8,25Speed 5 (1) kW 1,95 2,46 2,31 2,59 2,87 3,26 4,67 5,11 6,27 6,63Speed 6 (1) kW 1,72 2,17 2,04 2,29 2,25 2,50 3,54 3,75 4,81 5,06Sensible output cooling capacity (1)Speed 1 (1) kW 2,32 2,72 3,13 3,45 4,39 4,90 5,45 5,90 7,53 7,94Speed 2 (1) kW 2,21 2,59 2,87 3,19 3,90 4,38 5,14 5,52 7,21 7,62Speed 3 (1) kW 2,10 2,45 2,56 2,84 3,37 3,78 4,74 5,09 6,60 6,94Speed 4 (1) kW 1,93 2,24 2,26 2,50 2,73 3,04 4,20 4,44 5,66 5,91Speed 5 (1) kW 1,54 1,82 1,70 1,85 2,11 2,32 3,36 3,46 4,55 4,69Speed 6 (1) kW 1,35 1,59 1,49 1,63 1,63 1,76 2,43 2,43 3,33 3,33Max Water flow (1) l/h 480 610 690 810 960 1120 1260 1400 1710 1870Max Pressure drop (1) kPa 5 10 11 9 23 17 20 16 21 19Total output heating capacity (2)Speed 1 (2) kW 6,16 7,07 7,85 8,72 11,4 12,8 13,8 14,3 18,6 19,4Speed 2 (2) kW 5,88 6,73 7,26 7,98 10,1 11,3 12,9 13,4 17,8 18,5Speed 3 (2) kW 5,60 6,39 6,54 7,08 8,75 9,74 11,9 12,3 16,3 16,8Speed 4 (2) kW 5,17 5,86 5,82 6,22 7,11 7,82 10,4 10,8 14 14,3Speed 5 (2) kW 4,19 4,70 4,43 4,63 5,46 5,91 8,37 8,56 11,1 11,3Speed 6 (2) kW 3,70 4,11 3,90 4,04 4,19 4,48 6,11 6,16 8,39 8,38Max Water flow (2) l/h 540 620 770 770 1000 1130 1210 1260 1630 1700Max Pressure drop (2) kPa 4 9 10 8 20 16 18 13 18 16Total output heating capacity (3)Speed 1 (3) kW 3,75 4,29 4,76 5,34 6,90 7,86 8,58 9,14 11,3 12Speed 2 (3) kW 3,58 4,08 4,38 4,88 6,12 6,93 8,04 8,48 10,8 11,4Speed 3 (3) kW 3,41 3,87 3,91 4,33 5,31 5,96 7,42 7,72 9,86 10,4Speed 4 (3) kW 3,14 3,55 3,46 3,80 4,31 4,78 6,50 6,62 8,46 8,83Speed 5 (3) kW 2,55 2,84 2,61 2,76 3,30 3,61 5,14 5,14 6,74 6,86Speed 6 (3) kW 2,25 2,49 2,29 2,37 2,53 2,67 3,62 3,62 4,95 4,95Water flow Max (3) l/h 650 750 830 930 1200 1370 1500 1600 1970 2090Pressure drop Max (3) kPa 4 10 10 9 21 17 18 15 19 18Output supplementary coil (2)Speed 1 (2) kW 2,23 - 3,34 - 4,42 - 5,45 - 7,68 -Speed 2 (2) kW 2,15 - 3,13 - 4,02 - 5,19 - 7,43 -Speed 3 (2) kW 2,07 - 2,86 - 3,59 - 4,88 - 6,93 -Speed 4 (2) kW 1,94 - 2,59 - 3,04 - 4,42 - 6,16 -Speed 5 (2) kW 1,64 - 2,07 - 2,46 - 3,74 - 5,17 -Speed 6 (2) kW 1,48 - 1,87 - 1,99 - 2,94 - 4,15 -Water flow Max (2) l/h 200 - 290 - 390 - 480 - 670 -Pressure drop Max (2) kPa 4 - 13 - 20 - 35 - 10 -Sound pressure level (4)Speed 1 (4) dB(A) 48 49 51 52 51 52 54 55 57 58Speed 2 (4) dB(A) 44 45 47 48 47 48 49 50 53 54Speed 3 (4) dB(A) 40 41 44 45 44 45 45 46 49 50Speed 4 (4) dB(A) 37 38 42 43 40 41 42 43 43 44Speed 5 (4) dB(A) 31 32 33 34 33 34 36 37 38 39Speed 6 (4) dB(A) 30 31 31 32 30 31 34 35 31 32Water content l 1 1,30 1,40 19 1,80 2,40 2,20 2,90 2,60 3,50Fan 1 C 1 C 2 C 2 C 2 C 2 C 2 C 2 C 3 C 3 CWater IN connection inch 1/2” G F 1/2” G F 1/2” G F 1/2” G F 1/2” G F 1/2” G F 1/2” G F 1/2” G F 1/2” G F 1/2” G FMax absorbed power W 140 140 120 120 210 210 240 240 270 270Max absorbed current A 0,64 0,64 0,58 0,58 0,95 0,95 1,10 1,10 1,20 1,20Electrical power supply V-Ph~Hz 230-1-50 230-1-50 230-1-50 230-1-50 230-1-50 230-1-50 230-1-50 230-1-50 230-1-50 230-1-50DIMENSIONBuilt-inL (mm) 601 601 791 791 981 981 1171 1171 1361 1361H (mm) 495 495 495 495 495 495 495 495 495 495P (mm) 225 225 225 225 225 225 225 225 225 225Weight kg 18 18 21 21 27 27 29 29 40 40

2 PIPES4 PIPESCENTRIFUGALFAN COILDUCTCONTROLLER

Page 234: Products Guide V01 - ParagonEfficient project management thanks to Climaveneta as unique project leader. Complete and specialized Organization Climaveneta qualifies itself for the

232

Note:

1 Operation in cooling mode: room temperature 27°C d.b./19°C w.b., chilled water at inlet 7°C and at outlet 12°C

2 Operation in heating mode: room temperature 20°C d.b., hot water at inlet 70°C and at outlet 60°C

3 Operation in heating mode: room temperature 20°C d.b., hot water at inlet 50°C, with identical flow rate that in the cooling mode

4 Sound pressure in semianechoic room at 1 m from fan front and 1 m from the ground

a-LIFE HP / DFIModels 230 240 430 440 530 540 730 740 830 840Air flow rateSpeed 1 m3/h 520 520 600 600 930 930 960 960 1330 1330Speed 2 m3/h 490 490 540 540 800 800 890 890 1260 1260Speed 3 m3/h 460 460 470 470 670 670 810 810 1130 1130Speed 4 m3/h 415 415 405 405 520 520 695 695 940 940Speed 5 m3/h 320 320 290 290 380 380 540 540 720 720Speed 6 m3/h 275 275 250 250 280 280 380 380 520 520Effective static pressure Speed 1 - Max

Pa 40 40 40 40 40 40 40 40 40 40

Total output cooling capacity (1)Speed 1 (1) kW 2,83 3,57 4,04 4,69 5,58 6,54 7,36 8,15 9,95 10,9Speed 2 (1) kW 2,71 3,41 3,74 4,35 5,02 5,90 6,97 7,66 9,56 10,5Speed 3 (1) kW 2,59 3,25 3,37 3,91 4,41 5,15 6,47 7,09 8,83 9,60Speed 4 (1) kW 2,39 3 3,01 3,46 3,64 4,19 5,77 6,23 7,68 8,25Speed 5 (1) kW 1,95 2,46 2,31 2,59 2,87 3,26 4,67 5,11 6,27 6,63Speed 6 (1) kW 1,72 2,17 2,04 2,29 2,25 2,50 3,54 3,75 4,81 5,06Sensible output cooling capacity (1)Speed 1 (1) kW 2,32 2,72 3,13 3,45 4,39 4,90 5,45 5,90 7,53 7,94Speed 2 (1) kW 2,21 2,59 2,87 3,19 3,90 4,38 5,14 5,52 7,21 7,62Speed 3 (1) kW 2,10 2,45 2,56 2,84 3,37 3,78 4,74 5,09 6,60 6,94Speed 4 (1) kW 1,93 2,24 2,26 2,50 2,73 3,04 4,20 4,44 5,66 5,91Speed 5 (1) kW 1,54 1,82 1,70 1,85 2,11 2,32 3,36 3,46 4,55 4,69Speed 6 (1) kW 1,35 1,59 1,49 1,63 1,63 1,76 2,43 2,43 3,33 3,33Max Water flow (1) l/h 480 610 690 810 960 1120 1260 1400 1710 1870Max Pressure drop (1) kPa 5 10 11 9 23 17 20 16 21 19Total output heating capacity (2)Speed 1 (2) kW 6,16 7,07 7,85 8,72 11,4 12,8 13,8 14,3 18,6 19,4Speed 2 (2) kW 5,88 6,73 7,26 7,98 10,1 11,3 12,9 13,4 17,8 18,5Speed 3 (2) kW 5,60 6,39 6,54 7,08 8,75 9,74 11,9 12,3 16,3 16,8Speed 4 (2) kW 5,17 5,86 5,82 6,22 7,11 7,82 10,4 10,8 14 14,3Speed 5 (2) kW 4,19 4,70 4,43 4,63 5,46 5,91 8,37 8,56 11,1 11,3Speed 6 (2) kW 3,70 4,11 3,90 4,04 4,19 4,48 6,11 6,16 8,39 8,38Max Water flow (2) l/h 540 620 770 770 1000 1130 1210 1260 1630 1700Max Pressure drop (2) kPa 4 9 10 8 20 16 18 13 18 16Total output heating capacity (3)Speed 1 (3) kW 3,75 4,29 4,76 5,34 6,90 7,86 8,58 9,14 11,3 12Speed 2 (3) kW 3,58 4,08 4,38 4,88 6,12 6,93 8,04 8,48 10,8 11,4Speed 3 (3) kW 3,41 3,87 3,91 4,33 5,31 5,96 7,42 7,72 9,86 10,4Speed 4 (3) kW 3,14 3,55 3,46 3,80 4,31 4,78 6,50 6,62 8,46 8,83Speed 5 (3) kW 2,55 2,84 2,61 2,76 3,30 3,61 5,14 5,14 6,74 6,86Speed 6 (3) kW 2,25 2,49 2,29 2,37 2,53 2,67 3,62 3,62 4,95 4,95Water flow Max (3) l/h 650 750 830 930 1200 1370 1500 1600 1970 2090Pressure drop Max (3) kPa 4 10 10 9 21 17 18 15 19 18Output supplementary coil (2)Speed 1 (2) kW 2,23 - 3,34 - 4,42 - 5,45 - 7,68 -Speed 2 (2) kW 2,15 - 3,13 - 4,02 - 5,19 - 7,43 -Speed 3 (2) kW 2,07 - 2,86 - 3,59 - 4,88 - 6,93 -Speed 4 (2) kW 1,94 - 2,59 - 3,04 - 4,42 - 6,16 -Speed 5 (2) kW 1,64 - 2,07 - 2,46 - 3,74 - 5,17 -Speed 6 (2) kW 1,48 - 1,87 - 1,99 - 2,94 - 4,15 -Water flow Max (2) l/h 200 - 290 - 390 - 480 - 670 -Pressure drop Max (2) kPa 4 - 13 - 20 - 35 - 10 -Sound pressure level (4)Speed 1 (4) dB(A) 48 49 51 52 51 52 54 55 57 58Speed 2 (4) dB(A) 44 45 47 48 47 48 49 50 53 54Speed 3 (4) dB(A) 40 41 44 45 44 45 45 46 49 50Speed 4 (4) dB(A) 37 38 42 43 40 41 42 43 43 44Speed 5 (4) dB(A) 31 32 33 34 33 34 36 37 38 39Speed 6 (4) dB(A) 30 31 31 32 30 31 34 35 31 32Water content l 1 1,30 1,40 19 1,80 2,40 2,20 2,90 2,60 3,50Fan 1 C 1 C 2 C 2 C 2 C 2 C 2 C 2 C 3 C 3 CWater IN connection inch 1/2” G F 1/2” G F 1/2” G F 1/2” G F 1/2” G F 1/2” G F 1/2” G F 1/2” G F 1/2” G F 1/2” G FMax absorbed power W 140 140 120 120 210 210 240 240 270 270Max absorbed current A 0,64 0,64 0,58 0,58 0,95 0,95 1,10 1,10 1,20 1,20Electrical power supply V-Ph~Hz 230-1-50 230-1-50 230-1-50 230-1-50 230-1-50 230-1-50 230-1-50 230-1-50 230-1-50 230-1-50DIMENSIONBuilt-inL (mm) 601 601 791 791 981 981 1171 1171 1361 1361H (mm) 495 495 495 495 495 495 495 495 495 495P (mm) 225 225 225 225 225 225 225 225 225 225Weight kg 18 18 21 21 27 27 29 29 40 40

Page 235: Products Guide V01 - ParagonEfficient project management thanks to Climaveneta as unique project leader. Complete and specialized Organization Climaveneta qualifies itself for the

233

Dimension

P

H

L

Page 236: Products Guide V01 - ParagonEfficient project management thanks to Climaveneta as unique project leader. Complete and specialized Organization Climaveneta qualifies itself for the

234

Main accessoriesHot water coil kit 1 row and 2 rows

Kit RS485 - interface for Building Management System

Kit control board to manage 0-10V or 3 points modulating valve unit Main coil valve unit ON/OFF, 0-10 V, 3 points 2-way or 3-wayAdditional coil valve unit ON/OFF, PWM, 0-10 V, 3 points 3-way or 2-way

Kit LIFE BOX

FeaturesBrushless motor with permanent magnets electronic switches;Modulating centrifugal fan with fine regulation of the air flow;Four pipe system: 3+2 and 4+1 (number of rows for main + additional coil);Cabinet in galvanised steel with prevarnished finish for maximum resistance to rust;

Air filter on all models;

Automatically closing flap to cover and protect electric controls from dripping water (in conformity with directive 60335-2-40);

VersionsDFI built-in version, front air intake

DFU version with cabinet, front air intake

DLI built-in version, bottom air intake

DLU version with cabinet, bottom air intake

CommandsEK plug-in control /EKW wall mounted controlUser interface for selection of functioning mode (OFF/summer/winter/AUTO), fan speed (Max/Med/Min/AUTO), temperature set. Control of main coil valve unit (summer/winter - 2 pipes installation) and additional coil (winter - 4 pipes installation). Management of traditional ON/OFF valve unit or modulating valve unit 0-10V or 3 points (supply 230 VAC or 24V) . Air and water temperature probe. Multifunction digital input configurable by user. Configuration dip switch. Modbus protocol for installation in Building Management System (e.g. Idrorelax system by Climaveneta). Installation and management of Master-Slave system up to 8 LIFE fan coil units. Easy control installation thanks to 2 wires connection.

iK control with LCD screenInterface with LCD screen with user-friendly icons. Control kit for universal installation: wall-mounted as well as plug-in. Selection of functioning mode (OFF/summer/winter/AUTO), fan speed (Max/Med/Min/AUTO), temperature set. Control iK could function manually or with weekly timer regulation configurable by the customer. Control of main coil valve unit (summer/winter - 2 pipes) and additional coil (winter - 4 pipes). Management of traditional ON/OFF valve unit or modulating valve unit 0-10V or 3 points (supply 230 VAC or 24V) . Parameters configurable directly by user. Modbus protocol for installation in Building Management System (e.g. Idrorelax system by Climaveneta). Installation and management of Master-Slave system up to 8 LIFE fan coil units. Easy control installation thanks to 2 wires connection.

Hydronic terminals

i-LIFE 130÷640

Fan-coil with high efficiency brushless motor, continuous air flow modulation, universal installation

1,91 - 7,47 kWUnit DescriptionNEW i-LIFE fan-coil is powered by modulating speed centrifugal fan. This new generation of fan-coil guarantees air flow regulation from 0% to 100% and energy consumption is reduced by more than 50% respect traditional unit. Furthermore new commands are available to manage all functions offered by this range of terminal units.

Page 237: Products Guide V01 - ParagonEfficient project management thanks to Climaveneta as unique project leader. Complete and specialized Organization Climaveneta qualifies itself for the

235

Note:

1 Operation in cooling mode: room temperature 27°C d.b./19°C w.b., chilled water at inlet 7°C and at outlet 12°C

2 Operation in heating mode: room temperature 20°C d.b., hot water at inlet 70°C and at outlet 60°C

3 Operation in heating mode: room temperature 20°C d.b., hot water at inlet 50°C, with identical flow rate that in the cooling mode

4 Sound pressure in semianechoic room at 1 m from fan front and 1 m from the ground

i-LIFE / DLUModels 130 140 230 240 330 340 430 440 530 540 630 640Air flow rateSpeed 1 m3/h 410 390 480 450 485 460 815 790 915 880 925 900Speed 2 m3/h 360 340 410 380 415 390 680 660 780 750 790 770Speed 3 m3/h 315 290 350 320 355 330 565 545 680 655 685 670Speed 4 m3/h 270 250 300 270 305 280 470 455 585 560 590 560Speed 5 m3/h 200 180 225 210 230 220 315 300 440 420 445 440Speed 6 m3/h 105 95 120 110 130 120 200 190 310 295 320 305Total output cooling capacity (1)Speed 1 (1) kW 1,91 2,32 2,67 3,20 3,22 3,68 4,69 5,57 5,75 6,54 6,92 7,47Speed 2 (1) kW 1,75 2,10 2,37 2,81 2,86 3,23 4,14 4,87 5,13 5,80 6,16 6,57Speed 3 (1) kW 1,59 1,87 2,10 2,46 2,53 2,79 3,62 4,22 4,65 5,26 5,53 5,84Speed 4 (1) kW 1,42 1,67 1,85 2,13 2,24 2,42 3,16 3,65 4,15 4,63 4,88 5,08Speed 5 (1) kW 1,11 1,27 1,42 1,71 1,77 1,97 2,31 2,56 3,36 3,66 3,90 4,14Speed 6 (1) kW 0,70 0,75 0,88 1,00 1,06 1,16 1,56 1,64 2,53 2,72 2,95 2,95Sensible output cooling capacity (1)Speed 1 (1) kW 1,63 1,77 2,17 2,41 2,47 2,68 3,77 4,20 4,50 4,86 5,13 5,40Speed 2 (1) kW 1,47 1,58 1,91 2,09 2,17 2,34 3,27 3,62 3,96 4,27 4,52 4,72Speed 3 (1) kW 1,32 1,39 1,67 1,82 1,90 2,01 2,82 3,10 3,54 3,84 4,03 4,17Speed 4 (1) kW 1,16 1,23 1,46 1,56 1,67 1,73 2,42 2,66 3,12 3,35 3,53 3,59Speed 5 (1) kW 0,89 0,93 1,11 1,24 1,30 1,40 1,72 1,84 2,48 2,61 2,78 2,82Speed 6 (1) kW 0,53 0,54 0,66 0,70 0,77 0,77 1,15 1,18 1,84 1,91 2,07 1,95Max Water flow (1) l/h 330 400 460 550 550 630 800 960 990 1120 1190 1280Max Pressure drop (1) kPa 5 10 5 8 7 5 14 11 22 18 18 14Total output heating capacity (2)Speed 1 (2) kW 4,46 5,01 5,79 6,28 6,36 6,76 9,58 10,7 11,2 12,3 13,1 13,5Speed 2 (2) kW 4,04 4,49 5,12 5,44 5,60 5,85 8,33 9,18 9,88 10,7 11,4 11,8Speed 3 (2) kW 3,66 3,94 4,51 4,70 4,92 5,05 7,19 7,81 8,85 9,56 10,1 10,4Speed 4 (2) kW 3,25 3,49 3,98 4,05 4,33 4,36 6,20 6,69 7,83 8,34 8,88 8,85Speed 5 (2) kW 2,56 2,64 3,13 3,24 3,39 3,50 4,45 4,63 6,18 6,47 6,91 7,09Speed 6 (2) kW 1,50 1,49 1,81 1,78 2,04 1,94 3,00 3,05 4,58 4,70 5,12 4,44Max Water flow (2) l/h 390 440 510 550 560 590 840 930 980 1080 1150 1190Max Pressure drop (2) kPa 5 8 4 7 6 5 12 10 19 15 11 12Total output heating capacity (3)Speed 1 (3) kW 2,71 3,04 3,52 3,80 3,86 4,09 5,83 6,46 6,81 7,44 7,93 8,25Speed 2 (3) kW 2,46 2,72 3,11 3,30 3,40 3,54 5,06 5,57 6 6,50 6,93 7,19Speed 3 (3) kW 2,22 2,39 2,74 2,84 2,98 3,05 4,37 4,73 5,37 5,79 6,12 6,35Speed 4 (3) kW 1,97 2,11 2,41 2,45 2,62 2,63 3,76 4,05 4,75 5,05 5,37 5,33Speed 5 (3) kW 1,55 1,60 1,90 1,96 2,05 2,09 2,69 2,80 3,75 3,91 4,18 4,19Speed 6 (3) kW 0,91 0,90 1,10 1,05 1,23 1,14 1,82 1,80 2,77 2,81 3,05 2,90Water flow Max (3) l/h 470 530 610 660 670 710 1020 1130 1190 1300 1380 1440Pressure drop Max (3) kPa 5 8 5 7 6 5 13 10 20 16 16 12Output supplementary coil (2)Speed 1 (2) kW 1,48 - 2,12 - 2,48 - 3,48 - 4,11 - 4,52 -Speed 2 (2) kW 1,37 - 1,92 - 2,24 - 3,13 - 3,71 - 4,09 -Speed 3 (2) kW 1,26 - 1,74 - 2,02 - 2,78 - 3,40 - 3,72 -Speed 4 (2) kW 1,15 - 1,57 - 1,82 - 2,46 - 3,09 - 3,37 -Speed 5 (2) kW 0,95 - 1,30 - 1,50 - 1,92 - 2,55 - 2,78 -Speed 6 (2) kW 0,62 - 0,84 - 1,00 - 1,36 - 2,01 - 2,21 -Water flow Max (2) l/h 130 - 190 - 220 - 310 - 360 - 400 -Pressure drop Max (2) kPa 2 - 4 - 7 - 13 - 20 - 24 -Sound pressure level (4)Speed 1 (4) dB(A) 46 47 48 49 48 49 51 52 51 52 52 53Speed 2 (4) dB(A) 41 42 44 45 44 45 47 48 47 48 48 49Speed 3 (4) dB(A) 38 39 40 41 40 41 43 44 44 45 45 46Speed 4 (4) dB(A) 35 36 37 38 37 38 41 42 40 42 41 42Speed 5 (4) dB(A) 30 31 30 31 31 32 33 34 33 34 35 36Speed 6 (4) dB(A) 22 22 23 23 24 24 25 25 26 26 26 26Water content l 0,70 0,70 1 1 1,40 1,40 1,40 1 1,80 1,40 2,20 2,20Fan 1 C 1 C 1 C 1 C 1 C 1 C 2 C 2 C 2 C 2 C 2 C 2 CWater IN connection inch 1/2”G F 1/2”G F 1/2”G F 1/2”G F 1/2”G F 1/2”G F 1/2”G F 1/2”G F 1/2”G F 1/2”G F 1/2”G F 1/2”G FWater OUT connection inchMax absorbed power W 33 33 34 34 37 37 59 59 72 72 74 74Min absorbed power W 4 4 4 4 4 4 7 7 7 7 7 7Max absorbed current A 0,29 0,29 0,29 0,29 0,31 0,31 0,49 0,49 0,57 0,57 0,58 0,58Electrical power supply V-Ph~Hz 230-1-50 230-1-50 230-1-50 230-1-50 230-1-50 230-1-50 230-1-50 230-1-50 230-1-50 230-1-50 230-1-50 230-1-50DIMENSIONWith Cabinet L (mm) 732 732 922 922 1112 1112 1112 1112 1302 1302 1492 1492H (mm) 541 541 541 541 541 541 541 541 541 541 541 541P (mm) 233 233 233 233 233 233 233 233 233 233 233 233Weight kg 18 18 22 22 26 26 28 28 32 32 38 38

2 PIPES4 PIPESCENTRIFUGALFAN COILCONTROLLER

Page 238: Products Guide V01 - ParagonEfficient project management thanks to Climaveneta as unique project leader. Complete and specialized Organization Climaveneta qualifies itself for the

236

Note:

1 Operation in cooling mode: room temperature 27°C d.b./19°C w.b., chilled water at inlet 7°C and at outlet 12°C

2 Operation in heating mode: room temperature 20°C d.b., hot water at inlet 70°C and at outlet 60°C

3 Operation in heating mode: room temperature 20°C d.b., hot water at inlet 50°C, with identical flow rate that in the cooling mode

4 Sound pressure in semianechoic room at 1 m from fan front and 1 m from the ground

i-LIFE / DFUModels 130 140 230 240 330 340 430 440 530 540 630 640Air flow rateSpeed 1 m3/h 410 390 480 450 485 460 815 790 915 880 925 900Speed 2 m3/h 360 340 410 380 415 390 680 660 780 750 790 770Speed 3 m3/h 315 290 350 320 355 330 565 545 680 655 685 670Speed 4 m3/h 270 250 300 270 305 280 470 455 585 560 590 560Speed 5 m3/h 200 180 225 210 230 220 315 300 440 420 445 440Speed 6 m3/h 105 95 120 110 130 120 200 190 310 295 320 305Total output cooling capacity (1)Speed 1 (1) kW 1,91 2,32 2,67 3,20 3,22 3,68 4,69 5,57 5,75 6,54 6,92 7,47Speed 2 (1) kW 1,75 2,10 2,37 2,81 2,86 3,23 4,14 4,87 5,13 5,80 6,16 6,57Speed 3 (1) kW 1,59 1,87 2,10 2,46 2,53 2,79 3,62 4,22 4,65 5,26 5,53 5,84Speed 4 (1) kW 1,42 1,67 1,85 2,13 2,24 2,42 3,16 3,65 4,15 4,63 4,88 5,08Speed 5 (1) kW 1,11 1,27 1,42 1,71 1,77 1,97 2,31 2,56 3,36 3,66 3,90 4,14Speed 6 (1) kW 0,70 0,75 0,88 1,00 1,06 1,16 1,56 1,64 2,53 2,72 2,95 2,95Sensible output cooling capacity (1)Speed 1 (1) kW 1,63 1,77 2,17 2,41 2,47 2,68 3,77 4,20 4,50 4,86 5,13 5,40Speed 2 (1) kW 1,47 1,58 1,91 2,09 2,17 2,34 3,27 3,62 3,96 4,27 4,52 4,72Speed 3 (1) kW 1,32 1,39 1,67 1,82 1,90 2,01 2,82 3,10 3,54 3,84 4,03 4,17Speed 4 (1) kW 1,16 1,23 1,46 1,56 1,67 1,73 2,42 2,66 3,12 3,35 3,53 3,59Speed 5 (1) kW 0,89 0,93 1,11 1,24 1,30 1,40 1,72 1,84 2,48 2,61 2,78 2,82Speed 6 (1) kW 0,53 0,54 0,66 0,70 0,77 0,77 1,15 1,18 1,84 1,91 2,07 1,95Max Water flow (1) l/h 330 400 460 550 550 630 800 960 990 1120 1190 1280Max Pressure drop (1) kPa 5 10 5 8 7 5 14 11 22 18 18 14Total output heating capacity (2)Speed 1 (2) kW 4,46 5,01 5,79 6,28 6,36 6,76 9,58 10,7 11,2 12,3 13,1 13,5Speed 2 (2) kW 4,04 4,49 5,12 5,44 5,60 5,85 8,33 9,18 9,88 10,7 11,4 11,8Speed 3 (2) kW 3,66 3,94 4,51 4,70 4,92 5,05 7,19 7,81 8,85 9,56 10,1 10,4Speed 4 (2) kW 3,25 3,49 3,98 4,05 4,33 4,36 6,20 6,69 7,83 8,34 8,88 8,85Speed 5 (2) kW 2,56 2,64 3,13 3,24 3,39 3,50 4,45 4,63 6,18 6,47 6,91 7,09Speed 6 (2) kW 1,50 1,49 1,81 1,78 2,04 1,94 3,00 3,05 4,58 4,70 5,12 4,44Max Water flow (2) l/h 390 440 510 550 560 590 840 930 980 1080 1150 1190Max Pressure drop (2) kPa 5 8 4 7 6 5 12 10 19 15 11 12Total output heating capacity (3)Speed 1 (3) kW 2,71 3,04 3,52 3,80 3,86 4,09 5,83 6,46 6,81 7,44 7,93 8,25Speed 2 (3) kW 2,46 2,72 3,11 3,30 3,40 3,54 5,06 5,57 6 6,50 6,93 7,19Speed 3 (3) kW 2,22 2,39 2,74 2,84 2,98 3,05 4,37 4,73 5,37 5,79 6,12 6,35Speed 4 (3) kW 1,97 2,11 2,41 2,45 2,62 2,63 3,76 4,05 4,75 5,05 5,37 5,33Speed 5 (3) kW 1,55 1,60 1,90 1,96 2,05 2,09 2,69 2,80 3,75 3,91 4,18 4,19Speed 6 (3) kW 0,91 0,90 1,10 1,05 1,23 1,14 1,82 1,80 2,77 2,81 3,05 2,90Water flow Max (3) l/h 470 530 610 660 670 710 1020 1130 1190 1300 1380 1440Pressure drop Max (3) kPa 5 8 5 7 6 5 13 10 20 16 16 12Output supplementary coil (2)Speed 1 (2) kW 1,48 - 2,12 - 2,48 - 3,48 - 4,11 - 4,52 -Speed 2 (2) kW 1,37 - 1,92 - 2,24 - 3,13 - 3,71 - 4,09 -Speed 3 (2) kW 1,26 - 1,74 - 2,02 - 2,78 - 3,40 - 3,72 -Speed 4 (2) kW 1,15 - 1,57 - 1,82 - 2,46 - 3,09 - 3,37 -Speed 5 (2) kW 0,95 - 1,30 - 1,50 - 1,92 - 2,55 - 2,78 -Speed 6 (2) kW 0,62 - 0,84 - 1,00 - 1,36 - 2,01 - 2,21 -Water flow Max (2) l/h 130 - 190 - 220 - 310 - 360 - 400 -Pressure drop Max (2) kPa 2 - 4 - 7 - 13 - 20 - 24 -Sound pressure level (4)Speed 1 (4) dB(A) 46 47 48 49 48 49 51 52 51 52 52 53Speed 2 (4) dB(A) 41 42 44 45 44 45 47 48 47 48 48 49Speed 3 (4) dB(A) 38 39 40 41 40 41 43 44 44 45 45 46Speed 4 (4) dB(A) 35 36 37 38 37 38 41 42 40 42 41 42Speed 5 (4) dB(A) 30 31 30 31 31 32 33 34 33 34 35 36Speed 6 (4) dB(A) 22 22 23 23 24 24 25 25 26 26 26 26Water content l 0,70 0,70 1 1 1,40 1,40 1,40 1 1,80 1,40 2,20 2,20Fan 1 C 1 C 1 C 1 C 1 C 1 C 2 C 2 C 2 C 2 C 2 C 2 CWater IN connection inch 1/2”G F 1/2”G F 1/2”G F 1/2”G F 1/2”G F 1/2”G F 1/2”G F 1/2”G F 1/2”G F 1/2”G F 1/2”G F 1/2”G FWater OUT connection inchMax absorbed power W 33 33 34 34 37 37 59 59 72 72 74 74Min absorbed power W 4 4 4 4 4 4 7 7 7 7 7 7Max absorbed current A 0,29 0,29 0,29 0,29 0,31 0,31 0,49 0,49 0,57 0,57 0,58 0,58Electrical power supply V-Ph~Hz 230-1-50 230-1-50 230-1-50 230-1-50 230-1-50 230-1-50 230-1-50 230-1-50 230-1-50 230-1-50 230-1-50 230-1-50DIMENSIONWith Cabinet L (mm) 732 732 922 922 1112 1112 1112 1112 1302 1302 1492 1492H (mm) 541 541 541 541 541 541 541 541 541 541 541 541P (mm) 245 245 245 245 245 245 245 245 245 245 245 245Weight kg 18 18 22 22 26 26 28 28 32 32 38 38

Page 239: Products Guide V01 - ParagonEfficient project management thanks to Climaveneta as unique project leader. Complete and specialized Organization Climaveneta qualifies itself for the

237

Note:

1 Operation in cooling mode: room temperature 27°C d.b./19°C w.b., chilled water at inlet 7°C and at outlet 12°C

2 Operation in heating mode: room temperature 20°C d.b., hot water at inlet 70°C and at outlet 60°C

3 Operation in heating mode: room temperature 20°C d.b., hot water at inlet 50°C, with identical flow rate that in the cooling mode

4 Sound pressure in semianechoic room at 1 m from fan front and 1 m from the ground

i-LIFE / DLIModels 130 140 230 240 330 340 430 440 530 540 630 640Air flow rateSpeed 1 m3/h 410 390 480 450 485 460 815 790 915 880 925 900Speed 2 m3/h 360 340 410 380 415 390 680 660 780 750 790 770Speed 3 m3/h 315 290 350 320 355 330 565 545 680 655 685 670Speed 4 m3/h 270 250 300 270 305 280 470 455 585 560 590 560Speed 5 m3/h 200 180 225 210 230 220 315 300 440 420 445 440Speed 6 m3/h 105 95 120 110 130 120 200 190 310 295 320 305Total output cooling capacity (1)Speed 1 (1) kW 1,91 2,32 2,67 3,20 3,22 3,68 4,69 5,57 5,75 6,54 6,92 7,47Speed 2 (1) kW 1,75 2,10 2,37 2,81 2,86 3,23 4,14 4,87 5,13 5,80 6,16 6,57Speed 3 (1) kW 1,59 1,87 2,10 2,46 2,53 2,79 3,62 4,22 4,65 5,26 5,53 5,84Speed 4 (1) kW 1,42 1,67 1,85 2,13 2,24 2,42 3,16 3,65 4,15 4,63 4,88 5,08Speed 5 (1) kW 1,11 1,27 1,42 1,71 1,77 1,97 2,31 2,56 3,36 3,66 3,90 4,14Speed 6 (1) kW 0,70 0,75 0,88 1,00 1,06 1,16 1,56 1,64 2,53 2,72 2,95 2,95Sensible output cooling capacity (1)Speed 1 (1) kW 1,63 1,77 2,17 2,41 2,47 2,68 3,77 4,20 4,50 4,86 5,13 5,40Speed 2 (1) kW 1,47 1,58 1,91 2,09 2,17 2,34 3,27 3,62 3,96 4,27 4,52 4,72Speed 3 (1) kW 1,32 1,39 1,67 1,82 1,90 2,01 2,82 3,10 3,54 3,84 4,03 4,17Speed 4 (1) kW 1,16 1,23 1,46 1,56 1,67 1,73 2,42 2,66 3,12 3,35 3,53 3,59Speed 5 (1) kW 0,89 0,93 1,11 1,24 1,30 1,40 1,72 1,84 2,48 2,61 2,78 2,82Speed 6 (1) kW 0,53 0,54 0,66 0,70 0,77 0,77 1,15 1,18 1,84 1,91 2,07 1,95Max Water flow (1) l/h 330 400 460 550 550 630 800 960 990 1120 1190 1280Max Pressure drop (1) kPa 5 10 5 8 7 5 14 11 22 18 18 14Total output heating capacity (2)Speed 1 (2) kW 4,46 5,01 5,79 6,28 6,36 6,76 9,58 10,7 11,2 12,3 13,1 13,5Speed 2 (2) kW 4,04 4,49 5,12 5,44 5,60 5,85 8,33 9,18 9,88 10,7 11,4 11,8Speed 3 (2) kW 3,66 3,94 4,51 4,70 4,92 5,05 7,19 7,81 8,85 9,56 10,1 10,4Speed 4 (2) kW 3,25 3,49 3,98 4,05 4,33 4,36 6,20 6,69 7,83 8,34 8,88 8,85Speed 5 (2) kW 2,56 2,64 3,13 3,24 3,39 3,50 4,45 4,63 6,18 6,47 6,91 7,09Speed 6 (2) kW 1,50 1,49 1,81 1,78 2,04 1,94 3,00 3,05 4,58 4,70 5,12 4,44Max Water flow (2) l/h 390 440 510 550 560 590 840 930 980 1080 1150 1190Max Pressure drop (2) kPa 5 8 4 7 6 5 12 10 19 15 11 12Total output heating capacity (3)Speed 1 (3) kW 2,71 3,04 3,52 3,80 3,86 4,09 5,83 6,46 6,81 7,44 7,93 8,25Speed 2 (3) kW 2,46 2,72 3,11 3,30 3,40 3,54 5,06 5,57 6 6,50 6,93 7,19Speed 3 (3) kW 2,22 2,39 2,74 2,84 2,98 3,05 4,37 4,73 5,37 5,79 6,12 6,35Speed 4 (3) kW 1,97 2,11 2,41 2,45 2,62 2,63 3,76 4,05 4,75 5,05 5,37 5,33Speed 5 (3) kW 1,55 1,60 1,90 1,96 2,05 2,09 2,69 2,80 3,75 3,91 4,18 4,19Speed 6 (3) kW 0,91 0,90 1,10 1,05 1,23 1,14 1,82 1,80 2,77 2,81 3,05 2,90Water flow Max (3) l/h 470 530 610 660 670 710 1020 1130 1190 1300 1380 1440Pressure drop Max (3) kPa 5 8 5 7 6 5 13 10 20 16 16 12Output supplementary coil (2)Speed 1 (2) kW 1,48 - 2,12 - 2,48 - 3,48 - 4,11 - 4,52 -Speed 2 (2) kW 1,37 - 1,92 - 2,24 - 3,13 - 3,71 - 4,09 -Speed 3 (2) kW 1,26 - 1,74 - 2,02 - 2,78 - 3,40 - 3,72 -Speed 4 (2) kW 1,15 - 1,57 - 1,82 - 2,46 - 3,09 - 3,37 -Speed 5 (2) kW 0,95 - 1,30 - 1,50 - 1,92 - 2,55 - 2,78 -Speed 6 (2) kW 0,62 - 0,84 - 1,00 - 1,36 - 2,01 - 2,21 -Water flow Max (2) l/h 130 - 190 - 220 - 310 - 360 - 400 -Pressure drop Max (2) kPa 2 - 4 - 7 - 13 - 20 - 24 -Sound pressure level (4)Speed 1 (4) dB(A) 46 47 48 49 48 49 51 52 51 52 52 53Speed 2 (4) dB(A) 41 42 44 45 44 45 47 48 47 48 48 49Speed 3 (4) dB(A) 38 39 40 41 40 41 43 44 44 45 45 46Speed 4 (4) dB(A) 35 36 37 38 37 38 41 42 40 42 41 42Speed 5 (4) dB(A) 30 31 30 31 31 32 33 34 33 34 35 36Speed 6 (4) dB(A) 22 22 23 23 24 24 25 25 26 26 26 26Water content l 0,70 0,70 1 1 1,40 1,40 1,40 1 1,80 1,40 2,20 2,20Fan 1 C 1 C 1 C 1 C 1 C 1 C 2 C 2 C 2 C 2 C 2 C 2 CWater IN connection inch 1/2”G F 1/2”G F 1/2”G F 1/2”G F 1/2”G F 1/2”G F 1/2”G F 1/2”G F 1/2”G F 1/2”G F 1/2”G F 1/2”G FWater OUT connection inchMax absorbed power W 33 33 34 34 37 37 59 59 72 72 74 74Min absorbed power W 4 4 4 4 4 4 7 7 7 7 7 7Max absorbed current A 0,29 0,29 0,29 0,29 0,31 0,31 0,49 0,49 0,57 0,57 0,58 0,58Electrical power supply V-Ph~Hz 230-1-50 230-1-50 230-1-50 230-1-50 230-1-50 230-1-50 230-1-50 230-1-50 230-1-50 230-1-50 230-1-50 230-1-50DIMENSIONWith Cabinet L (mm) 411 411 601 601 791 791 791 791 981 981 1171 1171H (mm) 495 495 495 495 495 495 495 495 495 495 495 495P (mm) 225 225 225 225 225 225 225 225 225 225 225 225Weight kg 12 14 15 17 18 20 20 22 23 25 27 29

Page 240: Products Guide V01 - ParagonEfficient project management thanks to Climaveneta as unique project leader. Complete and specialized Organization Climaveneta qualifies itself for the

238

Note:

1 Operation in cooling mode: room temperature 27°C d.b./19°C w.b., chilled water at inlet 7°C and at outlet 12°C

2 Operation in heating mode: room temperature 20°C d.b., hot water at inlet 70°C and at outlet 60°C

3 Operation in heating mode: room temperature 20°C d.b., hot water at inlet 50°C, with identical flow rate that in the cooling mode

4 Sound pressure in semianechoic room at 1 m from fan front and 1 m from the ground

i-LIFE / DFIModels 130 140 230 240 330 340 430 440 530 540 630 640Air flow rateSpeed 1 m3/h 410 390 480 450 485 460 815 790 915 880 925 900Speed 2 m3/h 360 340 410 380 415 390 680 660 780 750 790 770Speed 3 m3/h 315 290 350 320 355 330 565 545 680 655 685 670Speed 4 m3/h 270 250 300 270 305 280 470 455 585 560 590 560Speed 5 m3/h 200 180 225 210 230 220 315 300 440 420 445 440Speed 6 m3/h 105 95 120 110 130 120 200 190 310 295 320 305Total output cooling capacity (1)Speed 1 (1) kW 1,91 2,32 2,67 3,20 3,22 3,68 4,69 5,57 5,75 6,54 6,92 7,47Speed 2 (1) kW 1,75 2,10 2,37 2,81 2,86 3,23 4,14 4,87 5,13 5,80 6,16 6,57Speed 3 (1) kW 1,59 1,87 2,10 2,46 2,53 2,79 3,62 4,22 4,65 5,26 5,53 5,84Speed 4 (1) kW 1,42 1,67 1,85 2,13 2,24 2,42 3,16 3,65 4,15 4,63 4,88 5,08Speed 5 (1) kW 1,11 1,27 1,42 1,71 1,77 1,97 2,31 2,56 3,36 3,66 3,90 4,14Speed 6 (1) kW 0,70 0,75 0,88 1,00 1,06 1,16 1,56 1,64 2,53 2,72 2,95 2,95Sensible output cooling capacity (1)Speed 1 (1) kW 1,63 1,77 2,17 2,41 2,47 2,68 3,77 4,20 4,50 4,86 5,13 5,40Speed 2 (1) kW 1,47 1,58 1,91 2,09 2,17 2,34 3,27 3,62 3,96 4,27 4,52 4,72Speed 3 (1) kW 1,32 1,39 1,67 1,82 1,90 2,01 2,82 3,10 3,54 3,84 4,03 4,17Speed 4 (1) kW 1,16 1,23 1,46 1,56 1,67 1,73 2,42 2,66 3,12 3,35 3,53 3,59Speed 5 (1) kW 0,89 0,93 1,11 1,24 1,30 1,40 1,72 1,84 2,48 2,61 2,78 2,82Speed 6 (1) kW 0,53 0,54 0,66 0,70 0,77 0,77 1,15 1,18 1,84 1,91 2,07 1,95Max Water flow (1) l/h 330 400 460 550 550 630 800 960 990 1120 1190 1280Max Pressure drop (1) kPa 5 10 5 8 7 5 14 11 22 18 18 14Total output heating capacity (2)Speed 1 (2) kW 4,46 5,01 5,79 6,28 6,36 6,76 9,58 10,7 11,2 12,3 13,1 13,5Speed 2 (2) kW 4,04 4,49 5,12 5,44 5,60 5,85 8,33 9,18 9,88 10,7 11,4 11,8Speed 3 (2) kW 3,66 3,94 4,51 4,70 4,92 5,05 7,19 7,81 8,85 9,56 10,1 10,4Speed 4 (2) kW 3,25 3,49 3,98 4,05 4,33 4,36 6,20 6,69 7,83 8,34 8,88 8,85Speed 5 (2) kW 2,56 2,64 3,13 3,24 3,39 3,50 4,45 4,63 6,18 6,47 6,91 7,09Speed 6 (2) kW 1,50 1,49 1,81 1,78 2,04 1,94 3,00 3,05 4,58 4,70 5,12 4,44Max Water flow (2) l/h 390 440 510 550 560 590 840 930 980 1080 1150 1190Max Pressure drop (2) kPa 5 8 4 7 6 5 12 10 19 15 11 12Total output heating capacity (3)Speed 1 (3) kW 2,71 3,04 3,52 3,80 3,86 4,09 5,83 6,46 6,81 7,44 7,93 8,25Speed 2 (3) kW 2,46 2,72 3,11 3,30 3,40 3,54 5,06 5,57 6 6,50 6,93 7,19Speed 3 (3) kW 2,22 2,39 2,74 2,84 2,98 3,05 4,37 4,73 5,37 5,79 6,12 6,35Speed 4 (3) kW 1,97 2,11 2,41 2,45 2,62 2,63 3,76 4,05 4,75 5,05 5,37 5,33Speed 5 (3) kW 1,55 1,60 1,90 1,96 2,05 2,09 2,69 2,80 3,75 3,91 4,18 4,19Speed 6 (3) kW 0,91 0,90 1,10 1,05 1,23 1,14 1,82 1,80 2,77 2,81 3,05 2,90Water flow Max (3) l/h 470 530 610 660 670 710 1020 1130 1190 1300 1380 1440Pressure drop Max (3) kPa 5 8 5 7 6 5 13 10 20 16 16 12Output supplementary coil (2)Speed 1 (2) kW 1,48 - 2,12 - 2,48 - 3,48 - 4,11 - 4,52 -Speed 2 (2) kW 1,37 - 1,92 - 2,24 - 3,13 - 3,71 - 4,09 -Speed 3 (2) kW 1,26 - 1,74 - 2,02 - 2,78 - 3,40 - 3,72 -Speed 4 (2) kW 1,15 - 1,57 - 1,82 - 2,46 - 3,09 - 3,37 -Speed 5 (2) kW 0,95 - 1,30 - 1,50 - 1,92 - 2,55 - 2,78 -Speed 6 (2) kW 0,62 - 0,84 - 1,00 - 1,36 - 2,01 - 2,21 -Water flow Max (2) l/h 130 - 190 - 220 - 310 - 360 - 400 -Pressure drop Max (2) kPa 2 - 4 - 7 - 13 - 20 - 24 -Sound pressure level (4)Speed 1 (4) dB(A) 46 47 48 49 48 49 51 52 51 52 52 53Speed 2 (4) dB(A) 41 42 44 45 44 45 47 48 47 48 48 49Speed 3 (4) dB(A) 38 39 40 41 40 41 43 44 44 45 45 46Speed 4 (4) dB(A) 35 36 37 38 37 38 41 42 40 42 41 42Speed 5 (4) dB(A) 30 31 30 31 31 32 33 34 33 34 35 36Speed 6 (4) dB(A) 22 22 23 23 24 24 25 25 26 26 26 26Water content l 0,70 0,70 1 1 1,40 1,40 1,40 1 1,80 1,40 2,20 2,20Fan 1 C 1 C 1 C 1 C 1 C 1 C 2 C 2 C 2 C 2 C 2 C 2 CWater IN connection inch 1/2”G F 1/2”G F 1/2”G F 1/2”G F 1/2”G F 1/2”G F 1/2”G F 1/2”G F 1/2”G F 1/2”G F 1/2”G F 1/2”G FWater OUT connection inchMax absorbed power W 33 33 34 34 37 37 59 59 72 72 74 74Min absorbed power W 4 4 4 4 4 4 7 7 7 7 7 7Max absorbed current A 0,29 0,29 0,29 0,29 0,31 0,31 0,49 0,49 0,57 0,57 0,58 0,58Electrical power supply V-Ph~Hz 230-1-50 230-1-50 230-1-50 230-1-50 230-1-50 230-1-50 230-1-50 230-1-50 230-1-50 230-1-50 230-1-50 230-1-50DIMENSIONWith Cabinet L (mm) 411 411 601 601 791 791 791 791 981 981 1171 1171H (mm) 495 495 495 495 495 495 495 495 495 495 495 495P (mm) 225 225 225 225 225 225 225 225 225 225 225 225Weight kg 12 14 15 17 18 20 20 22 23 25 27 29

Page 241: Products Guide V01 - ParagonEfficient project management thanks to Climaveneta as unique project leader. Complete and specialized Organization Climaveneta qualifies itself for the

239

Dimension

P

H

L P

H

L

Page 242: Products Guide V01 - ParagonEfficient project management thanks to Climaveneta as unique project leader. Complete and specialized Organization Climaveneta qualifies itself for the

240

Main accessoriesPair of decorative and structural feet

Air intake grille kit with version cover

IR reciver for CE comand with remote control

Interface SPB Kit

Rear panel for vertical housing

Horizontal and vertical fan coil auxiliary tray

Hose kit

In-line delivery plenum kit

Front air intake plenum for built-in version

Manual external air intake lock kit

Main coil valve unit ON/OFF, PWM

Additional coil valve unit ON/OFF, PWM

FeaturesPlastic air intake and outlet grille;

Very low noise fan unit;

6-speed autotransformer;

Air filter on all models;

Cabinet in galvanised steel for maximum resistance to rust;Automatically closing flap to cover and protect electric controls from dripping water (in conformity with directive 60335-2-40);

Lockable control covers;

Plug-in controls fixing bracket;

VersionsI version without cabinet

U version with cabinet

CommandsNSW wall mountedFan speed slider, mode slider (OFF/summer/winter). ON/OFF valve unit control (summer/winter for 2 pipes installation), ON/OFF second valve unit control (winter for 4 pipes installation). Setting for minimum temperature thermostat.

PSW wall mountedFan speed slider, mode slider (OFF/summer/winter). ON/OFF valve unit control (summer/winter for 2 pipes installation), ON/OFF second valve unit control (winter for 4 pipes installation). Remote water temperature probe.

MTW wall mountedFan speed slider, mode slider (OFF/summer/winter). Thermostat with set point regulation. ON/OFF valve unit control (summer/winter for 2 pipes installation), ON/OFF second valve unit control (winter for 4 pipes installation). Room temperature probe. Remote water temperature probe.

ATW wall mountedMode button (OFF/summer/winter/AUTO), fan speed button (Max/Med/Min/AUTO). Thermostat with set point regulation. ON/OFF valve unit control (summer/winter for 2 pipes installation), ON/OFF second valve unit control (winter for 4 pipes installation). Control of traditional or PWM modulating valve units. Room temperature probe and water temperature probe. Digital input configurable as: window contact, economy, heating or cooling remote changeover, periodic ventilation. Configuration dip switch. TTL serial port with Modbus protocol for installation in Building Management System.

CE Plug-in Control for plug-in installation on fan coil. Off/summer/winter/auto selector switch. Three speed/auto selector switch. Thermostat with set point regulation. Air and water probe. ON/OFF valve unit control (summer/winter for 2 pipes installation), ON/OFF second valve unit control (winter for 4 pipes installation).

PCE wall-mountedOff/summer/winter/auto selector switch. Room temperature control. Room temperature sensor. Coil temperature sensor. Three speed air flow control + Auto. Automatic summer/winter switching. Automatic ON/OFF valve control.

Hydronic terminals

NFT 102÷703

Residential fan-coils with cabinet or built-in version

0,86 - 4,25 kWUnit DescriptionNFT belongs to residential fan coil range by Climaveneta. This compact fan coil incorporates a tangential low noise fan. They are designed for residential market and small tertiary installation. Wall-mounted LIFE controls: NSW, PSW, MTW, ATW could be connected. NFT participates to EUROVENT certification programme.

Page 243: Products Guide V01 - ParagonEfficient project management thanks to Climaveneta as unique project leader. Complete and specialized Organization Climaveneta qualifies itself for the

241

Note:

1 Operation in cooling mode: room temperature 27°C d.b./19°C w.b., chilled water at inlet 7°C and at outlet 12°C

2 Operation in heating mode: room temperature 20°C d.b., hot water at inlet 70°C and at outlet 60°C

3 Operation in heating mode: room temperature 20°C d.b., hot water at inlet 50°C, with identical flow rate that in the cooling mode

4 Noise level measured at 1 m in open field conditions

5 Sound power on the basis of measurements made in compliance with Eurovent 8/2

NFT / UModels 102 202 302 402 502 603Air flow rateMax speed m3/h 310 310 410 410 590 610 Med speed m3/h 250 250 330 330 450 470 Min speed m3/h 175 175 250 250 300 320 Total output cooling capacity (1)Max speed (1) kW 0,86 1,51 2,02 2,51 3,4 4,25 Med speed (1) kW 0,62 1,18 1,7 2 2,75 3,5 Min speed (1) kW 0,49 0,85 1,35 1,63 1,95 2,4 Sensible output cooling capacity (1)Max speed (1) kW 0,8 1,22 1,67 1,97 2,65 3,32 Med speed (1) kW 0,56 0,92 1,36 1,52 2,05 2,65 Min speed (1) kW 0,4 0,67 1,05 1,23 1,4 1,75 Max Water flow (1) l/h 147 259 346 430 580 730 Max Pressure drop (1) kPa 10,6 9 24,5 27,1 28 25,6Total output heating capacity (2)Max speed (2) kW 2,3 3,5 4,6 5,7 7 9,5 Med speed (2) kW 1,9 3 3,8 4,5 5,8 7,2 Min speed (2) kW 1,42 2,2 3 3,6 4,5 5,5 Max Water flow (2) l/h 200 307 404 499 614 830 Max Pressure drop (2) kPa 3 3 9 13 16 14 Total output heating capacity (3)Max speed (3) kW 1,25 1,95 2,6 2,86 4,2 5,26Med speed (3) kW 0,97 1,6 2,3 2,35 3,3 4,23Min speed (3) kW 0,8 1,3 1,8 1,94 2,5 2,91Water flow Max (3) l/h 147 259 346 430 580 730 Pressure drop Max (3) kPa 10,4 8,2 22,9 24,9 27 17Output supplementary coil (2)Max speed (2) kW 2,1 2,1 2,7 2,9 3,3 3,8 Water flow Max (2) l/h 180 180 240 250 310 330 Pressure drop Max (2) kPa 3 3 9 10 11 13 Sound pressure level (4)Max speed (4) dB(A) 37 41 41 41 48 48Med speed (4) dB(A) 30 34 33 37 36 45Min speed (4) dB(A) 30 25 23 24 33 29 Sound power (5)Max speed (5) dB(A) 48 52 52 52 59 59Med speed (5) dB(A) 41 45 44 48 47 56Min speed (5) dB(A) 41 36 34 35 44 40 FanWater IN connection inch 1/2” G FWater OUT connection inch 1/2” G FMax absorbed power W 48 50 58 58 68 68 Max absorbed current A 0,23 0,24 0,25 0,25 0,35 0,35 Electrical power supply V-Ph~Hz 230V~50Hz 230V~50Hz 230V~50Hz 230V~50Hz 230V~50Hz 230V~50Hz DIMENSIONWith Cabinet L (mm) 720 720 910 910 1100 1100 H (mm) 535 535 535 535 535 535 P (mm) 200 200 200 200 200 200 Weight kg 18 19 22 23 25 27

2 PIPES4 PIPESTANGENZIALEFAN COILCONTROLLER

Page 244: Products Guide V01 - ParagonEfficient project management thanks to Climaveneta as unique project leader. Complete and specialized Organization Climaveneta qualifies itself for the

242

Note:

1 Operation in cooling mode: room temperature 27°C d.b./19°C w.b., chilled water at inlet 7°C and at outlet 12°C

2 Operation in heating mode: room temperature 20°C d.b., hot water at inlet 70°C and at outlet 60°C

3 Operation in heating mode: room temperature 20°C d.b., hot water at inlet 50°C, with identical flow rate that in the cooling mode

4 Noise level measured at 1 m in open field conditions

5 Sound power on the basis of measurements made in compliance with Eurovent 8/2

NFT / IModels 102 202 302 402 502 603Air flow rateMax speed m3/h 310 310 410 410 590 610 Med speed m3/h 250 250 330 330 450 470 Min speed m3/h 175 175 250 250 300 320 Total output cooling capacity (1)Max speed (1) kW 0,86 1,51 2,02 2,51 3,4 4,25 Med speed (1) kW 0,62 1,18 1,7 2 2,75 3,5 Min speed (1) kW 0,49 0,85 1,35 1,63 1,95 2,4 Sensible output cooling capacity (1)Max speed (1) kW 0,8 1,22 1,67 1,97 2,65 3,32 Med speed (1) kW 0,56 0,92 1,36 1,52 2,05 2,65 Min speed (1) kW 0,4 0,67 1,05 1,23 1,4 1,75 Max Water flow (1) l/h 147 259 346 430 580 730 Max Pressure drop (1) kPa 10,6 9 24,5 27,1 28 25,6Total output heating capacity (2)Max speed (2) kW 2,3 3,5 4,6 5,7 7 9,5 Med speed (2) kW 1,9 3 3,8 4,5 5,8 7,2 Min speed (2) kW 1,42 2,2 3 3,6 4,5 5,5 Max Water flow (2) l/h 200 307 404 499 614 830 Max Pressure drop (2) kPa 3 3 9 13 16 14 Total output heating capacity (3)Max speed (3) kW 1,25 1,95 2,6 2,86 4,2 5,26Med speed (3) kW 0,97 1,6 2,3 2,35 3,3 4,23Min speed (3) kW 0,8 1,3 1,8 1,94 2,5 2,91Water flow Max (3) l/h 147 259 346 430 580 730 Pressure drop Max (3) kPa 10,4 8,2 22,9 24,9 27 17Output supplementary coil (2)Max speed (2) kW 2,1 2,1 2,7 2,9 3,3 3,8 Water flow Max (2) l/h 180 180 240 250 310 330 Pressure drop Max (2) kPa 3 3 9 10 11 13 Sound pressure level (4)Max speed (4) dB(A) 37 41 41 41 48 48Med speed (4) dB(A) 30 34 33 37 36 45Min speed (4) dB(A) 30 25 23 24 33 29 Sound power (5)Max speed (5) dB(A) 48 52 52 52 59 59Med speed (5) dB(A) 41 45 44 48 47 56Min speed (5) dB(A) 41 36 34 35 44 40 FanWater IN connection inch 1/2” G FWater OUT connection inch 1/2” G FMax absorbed power W 48 50 58 58 68 68 Max absorbed current A 0,23 0,24 0,25 0,25 0,35 0,35 Electrical power supply V-Ph~Hz 230V~50Hz 230V~50Hz 230V~50Hz 230V~50Hz 230V~50Hz 230V~50Hz DIMENSIONBuilt-inL (mm) 545 545 735 735 925 925 H (mm) 503 503 503 503 503 503 P (mm) 195 195 195 195 195 195 Weight kg 13 14 15 16 18 20

Dimension

LP

H

LP

H

Page 245: Products Guide V01 - ParagonEfficient project management thanks to Climaveneta as unique project leader. Complete and specialized Organization Climaveneta qualifies itself for the

243

Page 246: Products Guide V01 - ParagonEfficient project management thanks to Climaveneta as unique project leader. Complete and specialized Organization Climaveneta qualifies itself for the

244

Main accessoriesFrame kit

Solenoid valve 2 ways 1/2”

Solenoid valve kit 3 ways, 4 fits 1/2” with frame

Condensate drain pump

FeaturesFan coil in ABS with high mechanical characteristics and resistance to ageing;

Adjustable air flow direction;

Arrangement for right-left condensate drain pipe;

Removable panel;

Management of all functions by remote control

Versions- base version

CommandsRemote controlSet-point regulation. Selection of functioning mode (cool, heat, dehumidify, fan), fan speed (Max, Med, Min, AUTO). Main available function: Swing, Sleep, Timer. User-sfriendly compact remote control with fine aethetics.

Hydronic terminals

MHD 30÷60

Hydronic hi-wall fan-coil

2,15 - 4,7 kWUnit DescriptionMHD belongs to hi-wall fan-coils of Climaveneta. The compactness of this model and its exclusive elegance soften the visual impact and make it ideal for residential and small tertiary installations.

Page 247: Products Guide V01 - ParagonEfficient project management thanks to Climaveneta as unique project leader. Complete and specialized Organization Climaveneta qualifies itself for the

245

Note:

1 Operation in cooling mode: room temperature 27°C d.b./19°C w.b., chilled water at inlet 7°C and at outlet 12°C

2 Operation in heating mode: room temperature 20°C d.b., hot water at inlet 50°C, with identical flow rate that in the cooling mode

3 Sound power on the basis of measurements made in compliance with Eurovent 8/2

MHD / -Models 30 40 50 60Air flow rateMax speed m3/h 436 632 780 920Med speed m3/h 376 522 691 810Min speed m3/h 334 403 570 697Total output cooling capacity (1)Max speed (1) kW 2,15 2,80 4 4,70Med speed (1) kW 1,85 2 3,40 3,90Min speed (1) kW 1,65 1,75 3,10 3,35Sensible output cooling capacity (1)Max speed (1) kW 1,82 2,48 3,40 3,60Med speed (1) kW 1,60 1,75 2,90 3,30Min speed (1) kW 1,45 1,55 2,60 2,85Max Water flow (1) l/hMax Pressure drop (1) kPa 10 16 37 46Total output heating capacity (2)Max speed (2) kW 2,70 3,60 4,90 5,80Med speed (2) kW 2,30 2,55 4,20 4,85Min speed (2) kW 1,98 2,20 3,80 4,15Water flow Max (2) l/hPressure drop Max (2) kPa 9 15 35 4Sound power (3) dB(A)Max speed (3) dB(A) 45 52 55 60Med speed (3) dB(A) 42 42 52 56Min speed (3) dB(A) 38 39 48 53Water IN connection mm 12 12 12 12Water OUT connection mm 12 12 12 12Max absorbed power W 24 28 40 50Max absorbed current AElectrical power supply V-Ph~Hz 230-1-50 230-1-50 230-1-50 230-1-50DIMENSIONL mm 845 845 940 940H mm 270 270 298 298P mm 180 180 200 200Weight kg 10 10 13 13

2 PIPESTANGENZIALEWALLCONTROLLER

Dimension

A

PL

Page 248: Products Guide V01 - ParagonEfficient project management thanks to Climaveneta as unique project leader. Complete and specialized Organization Climaveneta qualifies itself for the

250

Main accessoriesInterface SPB Kit

Hot water coil kit

Air purifier module with actived carbon filter

Heating element module

Humidifier module

Delivery and intake plenum

Delivery plenum for round ducts

Two way intake plenum with air lock

Condensate drain pump

FeaturesUnit coils guarantee high efficiency thermal exchange with low pressure drop. Finned unit coils are made of copper tubes and high exchange surface area aluminium fins. Coils are always tested for leaks with dried air at 30 bar;Electrical power and control switchboard complete with electronic air flow regulator and terminal blocks for connection to power supply and remote control;Internal insulation in closed cell expanded polyethylene with suitable thick to limit heat loss and noise emission;The fan unit high pressure are fitted with balanced impellers to guarantee minimum noise levels;Structure and base plate in hot-dip galvanised steel for maximum resistance to rust;Extra modules available as accessories to the standard unit;Remote control to manage main unit functions to provide a total enviroment comfort. Full Auto function;Arrangement for electronic control of two on/off or modulating valve unit in the water circuit;

Versions- base version

E electronic regulation version with remote control

CommandsNSW wall mountedFan speed slider, mode slider (OFF/summer/winter). ON/OFF valve unit control (summer/winter for 2 pipes installation), ON/OFF second valve unit control (winter for 4 pipes installation). Setting for minimum temperature thermostat.

PSW wall mountedFan speed slider, mode slider (OFF/summer/winter). ON/OFF valve unit control (summer/winter for 2 pipes installation), ON/OFF second valve unit control (winter for 4 pipes installation). Remote water temperature probe.

MTW wall mountedFan speed slider, mode slider (OFF/summer/winter). Thermostat with set point regulation. ON/OFF valve unit control (summer/winter for 2 pipes installation), ON/OFF second valve unit control (winter for 4 pipes installation). Room temperature probe. Remote water temperature probe.

ATW wall mountedMode button (OFF/summer/winter/AUTO), fan speed button (Max/Med/Min/AUTO). Thermostat with set point regulation. ON/OFF valve unit control (summer/winter for 2 pipes installation), ON/OFF second valve unit control (winter for 4 pipes installation). Control of traditional or PWM modulating valve units. Room temperature probe and water temperature probe. Digital input configurable as: window contact, economy, heating or cooling remote changeover, periodic ventilation. Configuration dip switch. TTL serial port with Modbus protocol for installation in Building Management System.

PCE wall-mountedOff/summer/winter/auto selector switch. Room temperature control. Room temperature sensor. Coil temperature sensor. Three speed air flow control + Auto. Automatic summer/winter switching. Automatic ON/OFF valve control.

Hydronic terminals

HWD 602÷1104

Ducted type terminal

4,8 - 15,1 kWUnit DescriptionHWD are Climaveneta ducted hydronic terminal units. The fan units at available working pressures, through internal insulation, ensure excellent acoustic comfort levels. The compactness and ease of installation make HWD a suitable hydronic terminal unit for any type of setting.

Page 249: Products Guide V01 - ParagonEfficient project management thanks to Climaveneta as unique project leader. Complete and specialized Organization Climaveneta qualifies itself for the

251

Note:

1 Operation in cooling mode: room temperature 27°C d.b./19°C w.b., chilled water at inlet 7°C and at outlet 12°C

2 Operation in heating mode: room temperature 20°C d.b., hot water at inlet 50°C, with identical flow rate that in the cooling mode

3 Operation in heating mode: room temperature 20°C d.b., hot water at inlet 70°C and at outlet 60°C

4 Sound power on the basis of measurements made in compliance with Eurovent 8/12

HWD / -Models 602 703 803 904 1003 1104Air flow rateMax speed m3/h 1300 1300 1600 1600 2200 2500Med speed m3/h 1171 1171 1357 1357 1985 2243Min speed m3/h 1021 1021 1057 1057 1585 1771Useful head (basic unit with filter) Pa 60 60 60 60 60 60Total output cooling capacity (1)Max speed (1) kW 4,80 6,20 8,00 9,70 11,5 15,1Med speed (1) kW 4,50 5,70 7,20 8,50 10,7 13,9Min speed (1) kW 4,10 5,20 6,00 7,00 9,10 11,7Sensible output cooling capacity (1)Max speed (1) kW 3,00 4,00 5,20 6,50 7,40 10,2Med speed (1) kW 2,80 3,70 4,60 5,90 6,90 9,70Min speed (1) kW 2,60 3,40 3,90 4,80 6,00 8,00Max Pressure drop (1) kPa 12 8 14 13 24 23Total output heating capacity (2)Max speed (2) kW 6,61 8,48 10,5 12,1 14,8 18,7Med speed (2) kW 6,19 7,88 9,34 10,7 13,7 17,3Min speed (2) kW 5,65 7,13 7,75 8,73 11,6 14,3Pressure drop Max (2) kPa 10 7 12 11 21 20Output supplementary coil (3)Max speed (3) kW 9,10 9,10 11,8 11,8 16,7 18,0Pressure drop Max (3) kPa 9 9 14 14 13 15Sound power (4)Max speed (4) dB(A) 68 68 72 72 78 80Med speed (4) dB(A) 65 65 69 69 76 77Min speed (4) dB(A) 62 62 63 63 70 72Hydraulic connections main coil inch 1/2” 1/2” 3/4” 3/4” 1” 1”Hydraulic connections supplementary coil

inch 1/2” 1/2” 1/2” 1/2” 1/2” 1/2”

Max absorbed power W 370 370 440 440 900 900Max absorbed current A 1,30 1,30 1,55 1,55 3,50 3,50Electrical power supply V-Ph~Hz 230V~50Hz 230V~50Hz 230V~50Hz 230V~50Hz 230V~50Hz 230V~50HzDIMENSIONBuilt-inL (mm) 900 900 1050 1050 1250 1250H (mm) 295 295 295 295 315 315P (mm) 695 695 695 695 750 750Weight kg 41 43 50 52 63 63

2 PIPES4 PIPESCENTRIFUGALDUCTCONTROLLER

Page 250: Products Guide V01 - ParagonEfficient project management thanks to Climaveneta as unique project leader. Complete and specialized Organization Climaveneta qualifies itself for the

252

Note:

1 Operation in cooling mode: room temperature 27°C d.b./19°C w.b., chilled water at inlet 7°C and at outlet 12°C

2 Operation in heating mode: room temperature 20°C d.b., hot water at inlet 50°C, with identical flow rate that in the cooling mode

3 Operation in heating mode: room temperature 20°C d.b., hot water at inlet 70°C and at outlet 60°C

4 Sound power on the basis of measurements made in compliance with Eurovent 8/12

HWD / EModels 602 703 803 904 1003 1104Air flow rateMax speed m3/h 1300 1300 1600 1600 2200 2500Med speed m3/h 1171 1171 1357 1357 1985 2243Min speed m3/h 1021 1021 1057 1057 1585 1771Useful head (basic unit with filter) Pa 60 60 60 60 60 60Total output cooling capacity (1)Max speed (1) kW 4,80 6,20 8,00 9,70 11,5 15,1Med speed (1) kW 4,50 5,70 7,20 8,50 10,7 13,9Min speed (1) kW 4,10 5,20 6,00 7,00 9,10 11,7Sensible output cooling capacity (1)Max speed (1) kW 3,00 4,00 5,20 6,50 7,40 10,2Med speed (1) kW 2,80 3,70 4,60 5,90 6,90 9,70Min speed (1) kW 2,60 3,40 3,90 4,80 6,00 8,00Max Pressure drop (1) kPa 12 8 14 13 24 23Total output heating capacity (2)Max speed (2) kW 6,61 8,48 10,5 12,1 14,8 18,7Med speed (2) kW 6,19 7,88 9,34 10,7 13,7 17,3Min speed (2) kW 5,65 7,13 7,75 8,73 11,6 14,3Pressure drop Max (2) kPa 10 7 12 11 21 20Output supplementary coil (3)Max speed (3) kW 9,10 9,10 11,8 11,8 16,7 18,0Pressure drop Max (3) kPa 9 9 14 14 13 15Sound power (4)Max speed (4) dB(A) 68 68 72 72 78 80Med speed (4) dB(A) 65 65 69 69 76 77Min speed (4) dB(A) 62 62 63 63 70 72Hydraulic connections main coil inch 1/2” 1/2” 3/4” 3/4” 1” 1”Hydraulic connections supplementary coil

inch 1/2” 1/2” 1/2” 1/2” 1/2” 1/2”

Max absorbed power W 370 370 440 440 900 900Max absorbed current A 1,30 1,30 1,55 1,55 3,50 3,50Electrical power supply V-Ph~Hz 230V~50Hz 230V~50Hz 230V~50Hz 230V~50Hz 230V~50Hz 230V~50HzDIMENSIONBuilt-inL (mm) 900 900 1050 1050 1250 1250H (mm) 295 295 295 295 315 315P (mm) 695 695 695 695 750 750Weight kg 41 43 50 52 63 63

Dimension

L

P

H

Page 251: Products Guide V01 - ParagonEfficient project management thanks to Climaveneta as unique project leader. Complete and specialized Organization Climaveneta qualifies itself for the

253

Page 252: Products Guide V01 - ParagonEfficient project management thanks to Climaveneta as unique project leader. Complete and specialized Organization Climaveneta qualifies itself for the

254

Main accessoriesInterface SPB Kit

Hot water coil kit

Heating element module

Delivery and intake plenum

Intake grill

Two way intake plenum with air lock

Ceiling brackets

Auxiliary condensate collecting tray

FeaturesUnit coils guarantee high efficiency thermal exchange with low pressure drop. Finned unit coils are made of copper tubes and high exchange surface area aluminium fins. Coils are always tested for leaks with dried air at 30 bar;The electrical power and control switchboard includes electronic air flow regulator and terminal blocks for connection to power supply and remote control;Internal insulation in closed cell expanded polyethylene with suitable thick to limit heat loss and noise emission;The fan unit high pressure are fitted with balanced impellers to guarantee minimum noise levels;Cabinet in galvanised steel for maximum resistance to rust;Extra modules available as accessories to the standard unit;

Versions- base version

CommandsNSW wall mountedFan speed slider, mode slider (OFF/summer/winter). ON/OFF valve unit control (summer/winter for 2 pipes installation), ON/OFF second valve unit control (winter for 4 pipes installation). Setting for minimum temperature thermostat.

PSW wall mountedFan speed slider, mode slider (OFF/summer/winter). ON/OFF valve unit control (summer/winter for 2 pipes installation), ON/OFF second valve unit control (winter for 4 pipes installation). Remote water temperature probe.

MTW wall mountedFan speed slider, mode slider (OFF/summer/winter). Thermostat with set point regulation. ON/OFF valve unit control (summer/winter for 2 pipes installation), ON/OFF second valve unit control (winter for 4 pipes installation). Room temperature probe. Remote water temperature probe.

ATW wall mountedMode button (OFF/summer/winter/AUTO), fan speed button (Max/Med/Min/AUTO). Thermostat with set point regulation. ON/OFF valve unit control (summer/winter for 2 pipes installation), ON/OFF second valve unit control (winter for 4 pipes installation). Control of traditional or PWM modulating valve units. Room temperature probe and water temperature probe. Digital input configurable as: window contact, economy, heating or cooling remote changeover, periodic ventilation. Configuration dip switch. TTL serial port with Modbus protocol for installation in Building Management System.

PCE wall-mountedOff/summer/winter/auto selector switch. Room temperature control. Room temperature sensor. Coil temperature sensor. Three speed air flow control + Auto. Automatic summer/winter switching. Automatic ON/OFF valve control.

Hydronic terminals

HWD-HP 0071÷0121

High head ducted type terminal

16,8 - 29,8 kWUnit DescriptionHWD HP belongs to ducted type fan-coils high head of Climaveneta. The possibility of vertical or horizontal installation, airflow adjustment and attractive external panelling guarantees an ease installation and make the unit adaptable to any type of surroundings.

Page 253: Products Guide V01 - ParagonEfficient project management thanks to Climaveneta as unique project leader. Complete and specialized Organization Climaveneta qualifies itself for the

255

Note:

1 Operation in cooling mode: room temperature 27°C d.b./19°C w.b., chilled water at inlet 7°C and at outlet 12°C

2 Operation in heating mode: room temperature 20°C d.b., hot water at inlet 45°C and at outlet 40°C

3 Operation in heating mode: room temperature 20°C d.b., hot water at inlet 70°C and at outlet 60°C

4 Noise level measured at 1 m in open field conditions

HWD-HP / -Models 0071 0091 0101 0121Total output cooling capacity (1) kW 16,8 20 23,4 29,8 Sensitive output cooling capacity (1) kW 12,3 14,4 17,3 21,7 Total output heating capacity (2) kW 16,3 19,6 23 29,5 Heating capacity standard coil (3) kW 34,6 40 47,8 60,4 Output supplementary coil (3) kW 25 25 36 39 Pressure drop main coil (1) kPa 24 22 14 12 Pressure drop additional coil (3) kPa 14 14 19 22 Absorbed power kW 0,68 0,68 1,75 2,24 Absorbed current at nominal conditions

A 2,9 2,9 7,9 9,5

Nominal air flow m3/h 3200 3200 4400 5000 Useful head (basic unit with filter) Pa 105 93 250 141 Hydraulic connections main coil inch 1”1/4 1”1/4 1”1/2 1”1/2 Hydraulic connections supplementary coil

inch 3/4” 3/4” 1 1

Sound pressure level (4) dB(A) 60 60 66 69 Electrical power supply V-Ph~Hz 230V~50Hz 230V~50Hz 230V~50Hz 230V~50Hz DIMENSIONL mm 1300 1300 1500 1500 H mm 510 510 625 625 P mm 1119 1119 1349 1349 Weight kg 121 124 145 149

2 PIPES4 PIPESCENTRIFUGALDUCTCONTROLLER

Dimension

LP

H

Page 254: Products Guide V01 - ParagonEfficient project management thanks to Climaveneta as unique project leader. Complete and specialized Organization Climaveneta qualifies itself for the

256

Main accessoriesInterface SPB Kit

Hot water coil kit

Cool water coil kit

Heating element kit

FeaturesRemovable aluzink plate side panels;

Panels insulated and soundproofed with polyethylene/polyester with average thickness of 10 mm (mod. HRD 0021-0051) and 20 mm for the other models;High efficiency aluminium plate static type heat recovery units, with airflow separated by special seals;UE3 efficiency air filters, which may be easily removed from any side of the unit (bottom, side, top) for periodic cleaning;

Fan casings on vibration-isolation mountings;

Double inlet centrifugal fans for fresh air intake and used air extraction, which may be removed from any side of the unit for periodic maintenance;

Multi speed directly coupled electric motor;

A terminal block with a relay board is fitted on the unit to aid electrical connections and fan control;Stainless steel condensate collecting tray, with condensate drain directed downwards;

Versions- base version

CommandsNSW wall mountedFan speed slider, mode slider (OFF/summer/winter). ON/OFF valve unit control (summer/winter for 2 pipes installation), ON/OFF second valve unit control (winter for 4 pipes installation). Setting for minimum temperature thermostat.

PSW wall mountedFan speed slider, mode slider (OFF/summer/winter). ON/OFF valve unit control (summer/winter for 2 pipes installation), ON/OFF second valve unit control (winter for 4 pipes installation). Remote water temperature probe.

MTW wall mountedFan speed slider, mode slider (OFF/summer/winter). Thermostat with set point regulation. ON/OFF valve unit control (summer/winter for 2 pipes installation), ON/OFF second valve unit control (winter for 4 pipes installation). Room temperature probe. Remote water temperature probe.

ATW wall mountedMode button (OFF/summer/winter/AUTO), fan speed button (Max/Med/Min/AUTO). Thermostat with set point regulation. ON/OFF valve unit control (summer/winter for 2 pipes installation), ON/OFF second valve unit control (winter for 4 pipes installation). Control of traditional or PWM modulating valve units. Room temperature probe and water temperature probe. Digital input configurable as: window contact, economy, heating or cooling remote changeover, periodic ventilation. Configuration dip switch. TTL serial port with Modbus protocol for installation in Building Management System.

PCE wall-mountedOff/summer/winter/auto selector switch. Room temperature control. Room temperature sensor. Coil temperature sensor. Three speed air flow control + Auto. Automatic summer/winter switching. Automatic ON/OFF valve control.

Hydronic terminals

HRD 0021÷0151

Heat recuperator unit

290 - 4000 m3/hUnit DescriptionHRD heat recuperator units for residential and commercial application allow maximum room comfort and energy saving. In modern systems is becoming necessary to create forced ventilation, which involves air conditioned expelling; thereby consuming more energy and consequenting increasing costs. HRD heat recuperators have obviated such as problems using an aluminium static recovery unit that saves more than 50% energy, otherwise be lost with expelled stale air. HRD can be integrated in traditional systems with fan coils, chillers and radiators and may operate both in summer and winter. These units are recommended for suspended ceiling installation and may be suitably ducted to allow the fresh air intake and distribution.

Page 255: Products Guide V01 - ParagonEfficient project management thanks to Climaveneta as unique project leader. Complete and specialized Organization Climaveneta qualifies itself for the

257

Note:

1 Sound pressure measured at 1 m in open field conditions

HRD / -Models 0021 0031 0051 0071 0091 0101 0121 0151Max air flow m3/h 290 600 1000 1400 1900 2500 3200 4000Sound level Max (1) dB(A) 54 56 54 59,5 58 57,5 60,5 62Axle power available W 2x45 2x90 2x147 2x350 2x350 2x350 2x550 2x750Poles N° 4 2 4 4 4 4 4 4Max absorption A 1,3 1,8 3,0 5,8 6,2 6,0 11,4 6,2N° fan speeds N° 2 1 3 3 3 3 3 2Efficiency % 52,3 54,6 53,4 52,1 51,8 57,6 56,0 55,6Recuperated thermal power kW 1 3 5 6 8 12 15 19Renewal air temperature °C 8,10 8,70 8,30 8,00 7,90 9,40 9,00 8,90Efficiency G3 G3 G3 G3 G3 G3 G3 G3Frontal air speed m/s 1,7 3,6 2,9 4,1 4,5 3,8 4,3 4,3Protection grade IP 20 54 44 55 44 55 20 55Isolation grade B F F F F F F FESP Pa 40 80 90 140 120 110 170 170Electrical power supply internal unit V-Ph~Hz 230V~50Hz 230V~50Hz 230V~50Hz 230V~50Hz 230V~50Hz 230V~50Hz 230V~50Hz 400V-3N~50HzDIMENSIONL mm 990 990 1150 1350 1450 1700 1700 1700H mm 270 270 385 410 470 490 530 630P mm 750 750 860 900 900 1230 1230 1230Net weight kg 39 41 68 91 99 140 155 179

CENTRIFUGALPLATECONTROLLER

Dimension

H

L P

Page 256: Products Guide V01 - ParagonEfficient project management thanks to Climaveneta as unique project leader. Complete and specialized Organization Climaveneta qualifies itself for the

258

HPHPHH

Page 257: Products Guide V01 - ParagonEfficient project management thanks to Climaveneta as unique project leader. Complete and specialized Organization Climaveneta qualifies itself for the

259

PACHPAC

HP

AC

Page 258: Products Guide V01 - ParagonEfficient project management thanks to Climaveneta as unique project leader. Complete and specialized Organization Climaveneta qualifies itself for the

260

HPAC

i-AX 18÷90

Versions

STD base version with fan speed regulationfor i-BRE

MOD version with condensing fan speed regulationLT low outdoor temperature version with

condensing fan speed regulation

Features

Unit for installing inside or outside the room to be air-conditioned. Maximum resistance to rust thanks to galvanised sheetmetal structures and panels with powder-coated paintfinish. The panels are lined with sound-insulating materialto limit noise levels. The reliability and functionality of the compressor and allthe other parts are guaranteed by partners who are worldleaders in their sector.

NEW EC INVERTER fans with electronic commutation inorder to maximize the energy saving and reducing thenoise emissions. Condensing control for maximum low noise (optional). Standard G2/G4 filtering section, F6-F8 optional, to CEN-EN 779 with average degree of separation 90.1%ASHRAE. The filter is self-extinguishing. The microprocessor controls the compressor activationtimes with FIFO logic, thereby regulating the coolingcapacity; it also controls the operating alarms with thepossibility of interfacing to supervisor and remote-servicing systems. Switchboard to IEC 204-1/EN60204-1 Refrigerant circuit consisting in the standard version of aelectronic expansion valve, liquid solenoid valve, high/lowpressure switch, sight glass liquid indicator drier filter andoil separator in order to guarantee the right lubrification ofthe compressor at the low speed. Capillary Pre and After sales service.

Main accessories• Remote user terminal• Electric heating coil• Water heating coil• Humidifier• Vibration isolation frame with rubber mountings• Air distribution plenum• Sound absorber plenum for air outlet• Interface electronic board

Unit DescriptionDuctable close control units air-conditioners with capacity ranging from 7 to 100kW for vertical installation and cooling only, with optional heating by means ofheating elements and hot water, optional humidifer and dehumidifier for precisetemperature and humidity control. Particularly suitable for air conditioningtechnological, servers and IT rooms and all technological applications in general.The INVERTER compressor allows the cooling capacity modulation according tothe real internal load, particularly efficient at the partial loads and optimizing thepower absorbed and eliminating the start current. Units fitted with electronic

expansion valve and EC INVERTER fans, upflow or downflow.

CommandsEVOLUTIONSemi-graphic display 132 x 64 pixel, Programmable software, Record storage of 100 alarms, General alarm,Automatic reset after blackout, Compressor FIFO management, Integral LAN system, Standby management,Automatic rotation, Serious alarms, Operating contemporaneousness

Close control unit, direct expansion aircooled with INVERTER compressor7 - 100 kW

Page 259: Products Guide V01 - ParagonEfficient project management thanks to Climaveneta as unique project leader. Complete and specialized Organization Climaveneta qualifies itself for the

261

NOTE(1) Indoor conditions: 24°C-50% Condensing temp. 45°C - ESP 20Pa (2) Measured at 1,5 m height, 2 m in front of the unit in free field

18 29 50 70 90

F2 F3 F4 F5 F6

400/3N/50 400/3N/50 400/3N/50 400/3N/50 400/3N/50

R410A R410A R410A R410A R410A

1 1 1 2 2

16,60 28,07 53,14 68,40 84,68

16,60 28,07 50,30 67,30 84,68

1,00 1,00 0,95 0,98 1,00

4,09 7,14 13,92 16,47 21,03

3,65 3,24 3,12 3,25 3,12

6,27 10,62 23,68 22,06 22,70

6,27 10,62 23,68 22,06 22,70

1,00 1,00 1,00 1,00 1,00

1,24 1,96 4,85 4,82 4,83

20,42 34,77 56,52 85,31 93,47

18,44 31,10 51,30 74,60 89,77

0,90 0,89 0,91 0,87 0,96

5,66 8,00 15,24 22,49 24,49

4900 8000 13500 19000 25000

0,47 1,51 3,13 4,57 6,1

53 60 64 67 67

5 5 5 8 8

3,75 3,75 3,75 6 6

3 3 3 3 3

8 9 15 18 18

1000 1000 1550 2100 2650

500 790 790 790 790

1980 1980 1980 1980 1980

Models

Frame

Power supply V/Ph/Hz

Refrigerant

N° compressors

PERFORMANCES

High Speed

Total cooling capacity (1) kW

Sensible cooling capacity (1) kW

SHR (1)

Total compressors absorbed power kW

EER

Low speed

Total cooling capacity (1) kW

Sensible cooling capacity (1) kW

SHR (1)

Total compressors absorbed power kW

Booster (not continuative functioning)

Total cooling capacity (1) kW

Sensible cooling capacity (1) kW

SHR (1)

Total compressors absorbed power kW

VENTILATION

Nominal air flow volume mc/h

Fan absorbed power kW

Sound pressure level (2) dB(A)

HUMIDIFIER

Capacity kg/h

Absorbed power kW

ELECTRICAL HEATERS

Steps

Absorbed power kW

DIMENSIONS

L mm

P mm

H mm

Inverter i-AX

LP

H

Page 260: Products Guide V01 - ParagonEfficient project management thanks to Climaveneta as unique project leader. Complete and specialized Organization Climaveneta qualifies itself for the

262

HPAC

i-AW 18÷90

Versions

STD base version with fan speed regulationfor i-BDC

MOD_A version with condensing fan speed regulation

MOD_B version with condensing pressostatic regulation

Features

Unit for installing inside or outside the room to be air-conditioned. Maximum resistance to rust thanks to galvanised sheetmetal structures and panels with powder-coated paintfinish. The panels are lined with sound-insulating materialto limit noise levels. The reliability and functionality of the compressor and allthe other parts are guaranteed by partners who are worldleaders in their sector.

NEW EC INVERTER fans with electronic commutation inorder to maximize the energy saving and reducing thenoise emissions. Condensing control for maximum low noise (optional). Standard G2/G4 filtering section, F6-F8 optional, to CEN-EN 779 with average degree of separation 90.1%ASHRAE. The filter is self-extinguishing. The microprocessor controls the compressor activationtimes with FIFO logic, thereby regulating the coolingcapacity; it also controls the operating alarms with thepossibility of interfacing to supervisor and remote-servicing systems. Switchboard to IEC 204-1/EN60204-1 Refrigerant circuit consisting in the standard version of aelectronic expansion valve, liquid solenoid valve, high/lowpressure switch, sight glass liquid indicator drier filter andoil separator in order to guarantee the right lubrification ofthe compressor at the low speed. Capillary Pre and After sales service.

Main accessories• Remote user terminal• Electric heating coil• Water heating coil• Humidifier• Vibration isolation frame with rubber mountings• Air distribution plenum• Sound absorber plenum for air outlet• Special filter plenum for air outlet• Interface electronic board

Unit DescriptionDuctable close control units air-conditioners with capacity ranging from 7 to 100kW for vertical installation and cooling only, with optional heating by means ofheating elements and hot water, optional humidifer and dehumidifier for precisetemperature and humidity control. Particularly suitable for air conditioningtechnological, servers and IT rooms and all technological applications in general.The INVERTER compressor allows the cooling capacity modulation according tothe real internal load, particularly efficient at the partial loads and optimizing thepower absorbed and eliminating the start current. Units fitted with electronic

expansion valve and EC INVERTER fans, upflow or downflow.

CommandsEVOLUTIONSemi-graphic display 132 x 64 pixel, Programmable software, Record storage of 100 alarms, General alarm,Automatic reset after blackout, Compressor FIFO management, Integral LAN system, Standby management,Automatic rotation, Serious alarms, Operating contemporaneousness

Close control unit, direct expansionwater cooled with INVERTERcompressor 7 - 100 kW

Page 261: Products Guide V01 - ParagonEfficient project management thanks to Climaveneta as unique project leader. Complete and specialized Organization Climaveneta qualifies itself for the

263

NOTE(1) Indoor conditions :24°C-50% Water 30- 35°C - ESP 20Pa (2) Measured at 1,5 m height, 2 m in front of the unit in free field

18 29 50 70 90

F2 F3 F4 F5 F6

400/3N/50 400/3N/50 400/3N/50 400/3N/50 400/3N/50

R410A R410A R410A R410A R410A

1 1 1 2 2

17,35 29,32 55,00 72,25 91,52

17,04 28,60 50,80 69,48 89,80

0,98 0,98 0,92 0,96 0,98

3,68 6,38 13,02 14,47 19,64

4,18 3,71 3,40 3,80 3,56

7,27 12,33 25,67 23,61 25,36

7,27 12,33 25,67 23,61 25,36

1,00 1,00 1,00 1,00 1,00

0,96 1,43 3,83 3,99 3,92

21,69 35,30 58,07 88,03 100,09

18,96 31,10 52,00 75,90 93,10

0,87 0,88 0,90 0,86 0,93

4,97 7,83 14,46 21,00 23,64

4900 8000 13500 19000 25000

0,47 1,51 3,13 4,57 6,1

53 60 64 67 67

5 5 5 8 8

3,75 3,75 3,75 6 6

3 3 3 3 3

8 9 15 18 18

1000 1000 1550 2100 2650

500 790 790 790 790

1980 1980 1980 1980 1980

Models

Frame

Power supply V/Ph/Hz

Refrigerant

N° compressors

PERFORMANCES

High Speed

Total cooling capacity (1) kW

Sensible cooling capacity (1) kW

SHR (1)

Total compressors absorbed power kW

EER

Low speed

Total cooling capacity (1) kW

Sensible cooling capacity (1) kW

SHR (1)

Total compressors absorbed power kW

Booster (not continuative functioning)

Total cooling capacity (1) kW

Sensible cooling capacity (1) kW

SHR (1)

Total compressors absorbed power kW

VENTILATION

Nominal air flow volume mc/h

Fan absorbed power kW

Sound pressure level (2) dB(A)

HUMIDIFIER

Capacity kg/h

Absorbed power kW

ELECTRICAL HEATERS

Steps

Absorbed power kW

DIMENSIONS

L mm

P mm

H mm

Inverter i-AW

LP

H

Page 262: Products Guide V01 - ParagonEfficient project management thanks to Climaveneta as unique project leader. Complete and specialized Organization Climaveneta qualifies itself for the

264

HPAC

AX 07÷90

Versions

STD base versionLT low outdoor temperature version with condensing

fan speed regulationMOD version with condensing fan speed regulation

FeaturesUnit for installing inside or outside the room to beair-conditioned.Maximum resistance to rust thanks to galvanised sheetmetal structures and panels with powder-coated paint finish.The panels are lined with sound-insulating material to limitnoise levels.The reliability and functionality of the compressor and allthe other parts are guaranteed by partners who are worldleaders in their sector.Double-inlet centrifugal fan per standard installed, directlycoupled and suspended on vibration-isolation mountings.The fans are of the forward-bladed type for maximumefficiency and low noise. Available as option, EC INVERTERfans with electronic commutation, Backward Curved Fan typeto minimize energy consumption and noise emission.Condensing control for maximum low noise (optional).Standard G2/G4 filtering section, F6-F8 optional, toCEN-EN 779 with average degree of separation 90.1%ASHRAE. The filter is self-extinguishing.The microprocessor controls the compressor activationtimes with FIFO logic, thereby regulating the cooling capacity;it also controls the operating alarms with the possibility ofinterfacing to supervisor and remote-servicing systems.Switchboard to IEC 204-1/EN60204-1Refrigerant circuit consisting in the standard version of athermostatic valve with external equalization (electronicexpansion valve avaible as option), liquid solenoid valve,high/low pressure switch, sight glass liquid indicator anddrier filter.Capillary Pre and After sales service.

Main accessories• Remote user terminal• Electric heating coil• Water heating coil• Humidifier• Vibration isolation frame with rubber mountings• Air distribution plenum• Sound absorber plenum for air outlet• Interface electronic board• Electronic Thermostatic valve

Unit DescriptionDuctable close control air-conditioners with capacities ranging from 7 to 90 kW forvertical installation and cooling only, with optional heating by means of heatingelement or hot water, optional humidifier and dehumidifier for precise temperatureand humidity control. Particularly suitable for air-conditioning technological, serverand CED rooms and all technological applications in general. Units fitted withcentrifugal fans with upward airflow from the top or from the bottom.

External air condenser. Power supply 400V/3+N/50Hz (all models).

CommandsEVOLUTIONSemi-graphic display 132 x 64 pixel, Programmable software, Record storage of 100 alarms, General alarm,Automatic reset after blackout, Compressor FIFO management, Integral LAN system, Standby management,Automatic rotation, Serious alarms, Operating contemporaneousness

Close control unit, air cooled, directexpansion7 - 90 kW

Page 263: Products Guide V01 - ParagonEfficient project management thanks to Climaveneta as unique project leader. Complete and specialized Organization Climaveneta qualifies itself for the

NOTE(1) Indoor air: 24°C/50% r.h.; Condensing temp.: 45°C(2) Measured at 1,5 m high and 2 m front unit, in open field conditions

Models 07 10 15 18 20 26 29 39

Electrical power supply V-Ph~Hz 400/3+N/50

COOLING PERFORMANCES

Total cooling capacity (1) kW 7,20 9,60 16,3 19,1 23,3 28,9 31,8 41

Sensible cooling capacity (1) kW 7,20 9,20 16,3 18,2 23,3 28,8 29,9 41

SHR 1 0,96 1 0,95 1 1 0,94 1

COMPRESSORS

Quantity n° 1 1 1 1 1 1 1 1

Power absorbed kW 1,69 2,20 3,64 4,31 4,93 6 6,93 7,86

N° Circuits n° 1 1 1 1 1 1 1 1

Refrigerant R410A R410A R410A R410A R410A R410A R410A R410A

FANS

Fan air flow m3/h 2500 2500 4900 4900 6500 8000 8000 13500

N° Centrifugal fans n° 1 1 2 2 1 1 1 2

N° EC Inverter fans n° 1 1 2 2 1 1 1 2

Centrifugal fans power abs. kW 0,49 0,49 1 1 1,66 2,02 2,02 3,61

EC Inverter fans power abs. kW 0,27 0,27 0,53 0,53 0,89 1,69 1,69 3,51

ESP std. Pa 20 20 20 20 20 20 20 20

Sound pressure level (2) dB(A) 50 50 53 53 56 60 60 64

AIR FILTER

Degree filtration G2 G2 G2 G2 G4 G4 G4 G4

HUMIDIFIER

Capacity kg/h 3 3 5 5 5 5 5 5

Power absorbed kW 2,25 2,25 3,75 3,75 3,75 3,75 3,75 3,75

ELECTRICAL HEATERS

Steps n° 3 3 3 3 3 3 3 3

Power absorbed kW 4 4 8 8 9 9 9 15

DIMENSION

L mm 600 600 1000 1000 1000 1000 1000 1550

P mm 500 500 500 500 790 790 790 790

H mm 1980 1980 1980 1980 1980 1980 1980 1980

COUPLING EXTERNAL UNIT

BRE STD/LT/LN 014m 014m 022m 027m 027m 044m 044m 051m

Models 30 40 50 55 60 70 80 90

Electrical power supply V-Ph~Hz 400/3+N/50

COOLING PERFORMANCES

Total cooling capacity (1) kW 33,4 46,2 52,3 60,3 68,1 73,2 87,8 95,4

Sensible cooling capacity (1) kW 33,4 46,2 49,9 60,3 68,1 70,1 87,8 91,8

SHR 1 1 0,95 1 1 0,96 1 0,96

COMPRESSORS

Quantity n° 2 2 2 2 2 2 2 2

Power absorbed kW 7,26 9,85 12 12 13,9 15,7 17,7 21,3

N° Circuits n° 2 2 2 2 2 2 2 2

Refrigerant R410A R410A R410A R410A R410A R410A R410A R410A

FANS

Fan air flow m3/h 10500 13500 13500 19000 19000 19000 25000 25000

N° Centrifugal fans n° 2 2 2 2 2 2 - -

N° EC Inverter fans n° 2 2 2 3 3 3 4 4

Centrifugal fans power abs. kW 2,89 3,61 3,61 6,55 6,55 6,55 - -

EC Inverter fans power abs. kW 2,09 3,51 3,51 5,11 5,11 5,11 6,82 6,82

ESP std. Pa 20 20 20 20 20 20 20 20

Sound pressure level (2) dB(A) 59 64 64 67 67 67 67 67

AIR FILTER

Degree filtration G4 G4 G4 G4 G4 G4 G4 G4

HUMIDIFIER

Capacity kg/h 5 5 5 8 8 8 8 8

Power absorbed kW 3,75 3,75 3,75 6 6 6 6 6

ELECTRICAL HEATERS

Steps n° 3 3 3 3 3 3 3 3

Power absorbed kW 15 15 15 18 18 18 18 18

DIMENSION

L mm 1550 1550 1550 2100 2100 2100 2650 2650

P mm 790 790 790 790 790 790 790 790

H mm 1980 1980 1980 1980 1980 1980 1980 1980

COUPLING EXTERNAL UNIT

BRE STD/LT/LN 054b 054b 065b 065b 076b 100b 100b 116b

ACCURATE AX / STD

265

Page 264: Products Guide V01 - ParagonEfficient project management thanks to Climaveneta as unique project leader. Complete and specialized Organization Climaveneta qualifies itself for the

266

HPAC

AW 07÷90

Versions

STD base versionMOD_A version with condensing fan speed regulationMOD_B version with condensing pressostatic regulation

Unit DescriptionDucted close-control air-conditioners with capacities ranging from 7 to 90 kW forvertical installation and cooling only, with optional reheating by means of heatingelement or hot water, optional humidifier and dehumidifier for precise temperatureand humidity control. Particularly suitable for air-conditioning technological, serverand CED rooms and all technological applications in general. Units fitted withcentrifugal fans with upward airflow from the top and from the bottom andincorporated water-cooled condenser. External Dry Cooler.

Power supply 400V/3+N/50Hz (for all units).

CommandsEVOLUTIONSemi-graphic display 132 x 64 pixel, Programmable software, Record storage of 100 alarms, General alarm,Automatic reset after blackout, Compressor FIFO management, Integral LAN system, Standby management,Automatic rotation, Serious alarms, Operating contemporaneousness

Close control unit, water cooled directexpansion07 - 90 kW

FeaturesUnit for installing inside or outside the room to beair-conditioned.Maximum resistance to rust thanks to galvanised sheet metalstructures and panels with powder-coated paint finish.The panels are lined with sound-insulating material to limit noiselevels. The reliability and functionality of the compressor and allthe other parts are guaranteed by partners who are worldleaders in their sector.Double-inlet centrifugal fan per standard installed, directlycoupled and suspended on vibration-isolation mountings.The fans are of the forward-bladed type for maximum efficiencyand low noise. Available as option, EC INVERTER fans withelectronic commutation, Backward Curved Fan type tominimize energy consumption and noise emission.Condensing control for maximum low noise (optional).Standard G2/G4 filtering section, F6-F8 optional, toCEN-EN 779 with average degree of separation 90.1%ASHRAE. The filter is self-extinguishing.The microprocessor controls the compressor activation timeswith FIFO logic, thereby regulating the cooling capacity; it alsocontrols the operating alarms with the possibility of interfacingto supervisor and remote-servicing systems.Refrigerant circuit consisting in the standard version of athermostatic valve with external equalization (electronicexpansion valve avaible as option), liquid solenoid valve,high/low pressure switch, sight glass liquid indicator anddrier filter.Switchboard to IEC 204-1/EN60204-1Capillary Pre and After sales service.

Main accessories• Remote user terminal• Electric heating coil• Water heating coil• Humidifier• Vibration isolation frame with rubber mountings• Air distribution plenum• Sound absorber plenum for air outlet• Interface electronic board• Electronic Thermostatic valve

Page 265: Products Guide V01 - ParagonEfficient project management thanks to Climaveneta as unique project leader. Complete and specialized Organization Climaveneta qualifies itself for the

267

NOTE(1) Indoor air: 24°C/50% r.h.; Water: 30°-35°C(2) Measured at 1,5 m high and 2 m front unit, in open field conditions

Models 07 10 15 18 20 26 29 39

Electrical power supply V-Ph~Hz 400/3+N/50

COOLING PERFORMANCES

Total cooling capacity (1) kW 7,50 9,80 16,9 19,8 24,5 29,2 33 43

Sensible cooling capacity (1) kW 7,50 9,30 16,9 18,3 23,8 28,3 29,9 43

SHR 1 0,95 1 0,92 0,97 0,97 0,91 1

COMPRESSORS

Quantity n° 1 1 1 1 1 1 1 1

Power absorbed kW 1,47 1,91 3,26 3,93 4,28 5,38 6,24 6,91

N° Circuits n° 1 1 1 1 1 1 1 1

Refrigerant R410A R410A R410A R410A R410A R410A R410A R410A

FANS

Fan air flow m3/h 2500 2500 4900 4900 6500 8000 8000 13500

N° Centrifugal fans n° 1 1 2 2 1 1 1 2

N° EC Inverter fans n° 1 1 2 2 1 1 1 2

Centrifugal fans power abs. kW 0,49 0,49 1 1 1,66 2,02 2,02 3,61

EC Inverter fans power abs. kW 0,27 0,27 0,53 0,53 0,89 1,69 1,69 3,51

ESP std. Pa 20 20 20 20 20 20 20 20

Sound pressure level (2) dB(A) 50 50 53 53 56 60 60 64

AIR FILTER

Degree filtration G2 G2 G2 G2 G4 G4 G4 G4

HUMIDIFIER

Capacity kg/h 3 3 5 5 5 5 5 5

Power absorbed kW 2,25 2,25 3,75 3,75 3,75 3,75 3,75 3,75

ELECTRICAL HEATERS

Steps n° 3 3 3 3 3 3 3 3

Power absorbed kW 4 4 8 8 9 9 9 15

PLATE CONDENSER

Water flow rate (1) l/h 1520 2050 3390 4020 4820 5930 6730 8360

Pressure drop (1) kPa 8 14 5 7 23 30 27 24 30

DIMENSION

L mm 600 600 1000 1000 1000 1000 1000 1550

P mm 500 500 500 500 790 790 790 790

H mm 1980 1980 1980 1980 1980 1980 1980 1980

COUPLING EXTERNAL UNIT

BDC STD/LT/LN 013m 013m 030m 030m 030m 039m 039m 052m

Models 30 40 50 55 60 70 80 90

Electrical power supply V-Ph~Hz 400/3+N/50

COOLING PERFORMANCES

Total cooling capacity (1) kW 34,8 48,5 54,5 62,6 70,8 77,4 90,6 99,3

Sensible cooling capacity (1) kW 34,8 48,4 49,9 62,6 69,1 71,1 90 92,8

SHR 1 1 0,92 1 0,98 0,92 0,99 0,93

COMPRESSORS

Quantity n° 2 2 2 2 2 2 2 2

Power absorbed kW 6,42 8,53 10,8 10,8 12,4 13,5 15,9 19,2

N° Circuits n° 2 2 2 2 2 2 2 2

Refrigerant R410A R410A R410A R410A R410A R410A R410A R410A

FANS

Fan air flow m3/h 10500 13500 13500 19000 19000 19000 25000 25000

N° Centrifugal fans n° 2 2 2 2 2 2 - -

N° EC Inverter fans n° 2 2 2 3 3 3 4 4

Centrifugal fans power abs. kW 2,89 3,61 3,61 6,55 6,55 6,55 - -

EC Inverter fans power abs. kW 2,09 3,51 3,51 5,11 5,11 5,11 6,82 6,82

ESP std. Pa 20 20 20 20 20 20 20 20

Sound pressure level (2) dB(A) 59 64 64 67 67 67 67 67

AIR FILTER

Degree filtration G4 G4 G4 G4 G4 G4 G4 G4

HUMIDIFIER

Capacity kg/h 5 5 5 8 8 8 8 8

Power absorbed kW 3,75 3,75 3,75 6 6 6 6 6

ELECTRICAL HEATERS

Steps n° 3 3 3 3 3 3 3 3

Power absorbed kW 15 15 15 18 18 18 18 18

PLATE CONDENSER

Water flow rate (1) l/h 3460x2 4780x2 5715x2 6155x2 6975x2 7705x2 17850 20160

Pressure drop (1) kPa 21 30 33 30 26 31 39

DIMENSION

L mm 1550 1550 1550 2100 2100 2100 2650 2650

P mm 790 790 790 790 790 790 790 790

H mm 1980 1980 1980 1980 1980 1980 1980 1980

COUPLING EXTERNAL UNIT

BDC STD/LT/LN 039m 052m 062m 078m 078m 092m 103m 123m

ACCURATE AW / STD

Page 266: Products Guide V01 - ParagonEfficient project management thanks to Climaveneta as unique project leader. Complete and specialized Organization Climaveneta qualifies itself for the

268

HPAC

AD 20÷90

Versions

STD base versionLT low outdoor temperature version with

condensing fan speed regulationMOD version with condensing fan speed regulation

FeaturesUnit for installing inside or outside the room to beair-conditionedMaximum resistance to rust thanks to galvanised sheetmetal structures and panels with powder-coated paintfinish. The panels are lined with sound-insulating material.The reliability of all the components is guaranteed bypartners who are world leaders in their sector.NEW EC INVERTER fans with electronic commutation inorder to maximize the energy saving and reducing thenoise emissions.Standard G4 filtering section, F6-F8 optional, underCEN-EN 779 rule with the separation degree 90,1%ASHRAE. The filter is autoestinguishing type.The microprocessor controls all the main functions of theair conditioners; it also controls the operating alarmswith the possibility of interfacing to supervisor andremoteservicing systems.Electrical box under IEC 204-1/EN60204-1 rules.Capillary Pre and After sales service.

Main accessories• Remote user terminal• Electric heating coil• Water heating coil• Humidifier• Vibration isolation frame with rubber mountings• Air distribution plenum• Sound absorber plenum for air outlet• Interface electronic board• Electronic Thermostatic valve

Unit DescriptionDuctable close control units air-conditioners with capacity ranging from 20 to 100kW for vertical installation and cooling only, with optional heating by means ofheating elements and hot water, optional humidifer and dehumidifier for precisetemperature and humidity control. Particularly suitable for air conditioningtechnological, servers and IT rooms and all technological applications in general.Units fittend with EC INVERTER fans, upflow or downflow.

DUAL FLUID unit has to be connected to an external chiller for PRIMARY circuit.The direct expansion circuit, secondary or BACK-UP circuit, is air cooled and has

to be connected with a remote condenser.

CommandsEVOLUTIONSemi-graphic display 132 x 64 pixel, Programmable software, Record storage of 100 alarms, General alarm,Automatic reset after blackout, Compressor FIFO management, Integral LAN system, Standby management,Automatic rotation, Serious alarms, Operating contemporaneousness

Close control unit dual fluid, air cooleddirect expansion20 - 100 kW

Page 267: Products Guide V01 - ParagonEfficient project management thanks to Climaveneta as unique project leader. Complete and specialized Organization Climaveneta qualifies itself for the

269

NOTE(1) Indoor air: 24°C/50% r.h.; Condensing temp.: 45°C(2) Indoor air: 24°C/50% r.h.; Water (in/out): 7/12°C(3) Measured at 1,5 m high and 2 m front unit, in open field conditions

Models 20 26 29 39 30 40 50 60 70 80 90

Electrical power supply V-Ph~Hz 400/3+N/50

COOLING PERFORMANCES (DX)

Total cooling capacity (1) kW 23,7 29,4 32,7 42,2 36,7 47,6 55,1 62,1 75,5 86,3 98,8

Sensible cooling capacity (1) kW 21,8 27,9 30,2 42,2 36,2 47 50,7 62,1 71 86,1 91

SHR 0,92 0,95 0,92 1 0,99 0,99 0,92 1 0,94 1 0,92

COMPRESSORS

Quantity n° 1 1 1 1 2 2 2 2 2 2 2

Power abs. kW 4,93 6,01 6,75 7,87 7,15 9,87 11,7 12 15,4 17,7 21,4

N° Circuits n° 1 1 1 1 2 2 2 2 2 2 2

Refrigerant R410A R410A R410A R410A R410A R410A R410A R410A R410A R410A R410A

COOLING PERFORMANCES (CW)

Total cooling capacity (2) kW 23,8 28,1 29,5 20 41 50 51,4 65 67,6 91 91

Sensible cooling capacity (2) kW 21,8 26,4 27,6 46,3 37 46,3 47,5 62,2 64,5 85 85

SHR 0,92 0,94 0,94 0,93 0,90 0,93 0,92 0,96 0,95 0,93 0,93

Water flow rate (2) l/h 3890 4590 4590 8170 6710 8170 8170 10630 10630 14870 14870

Total pressure drop water side kPa 26 35 35 46 30 46 46 26 26 53 53

VENTILATION

Air flow mc/h 6000 7500 8000 13000 10000 13000 13500 18000 19000 24000 24000

N° EC Inverter fans n° 1 1 1 2 2 2 2 3 3 4 4

EC Inverter fans power abs. kW 0,89 1,60 1,80 3,40 2,09 3,40 3,65 4,50 5,20 6,82 6,82

ESP std. Pa 20 20 20 20 20 20 20 20 20 20 20

Sound pressure level (3) dB(A) 56 60 60 64 59 64 64 67 67 67 67

AIR FILTER

Degree filtration G4 G4 G4 G4 G4 G4 G4 G4 G4 G4 G4

HUMIDIFIER

Capacity kg/h 5 5 5 5 5 5 5 8 8 8 8

Power abs. kW 3,75 3,75 3,75 3,75 3,75 3,75 3,75 6 6 6 6

ELECTRICAL HEATERS

Steps 3 3 3 3 3 3 3 3 3 3 3

Power abs. kW 9 9 9 15 15 15 15 18 18 18 18

DIMENSION

L mm 1000 1000 1000 1550 1550 1550 1550 2100 2100 2650 2650

P mm 790 790 790 790 790 790 790 790 790 790 790

H mm 1980 1980 1980 1980 1980 1980 1980 1980 1980 1980 1980

COUPLING EXTERNAL UNIT

BRE STD/LT/LN 027m 044m 044m 051m 054b 054b 065b 076b 100b 100b 116b

LP

H

ACCURATE AD/STD

Page 268: Products Guide V01 - ParagonEfficient project management thanks to Climaveneta as unique project leader. Complete and specialized Organization Climaveneta qualifies itself for the

270

HPAC

AT 20÷90

Versions

STD base versionMOD_A version with condensing fan speed regulationMOD_B version with condensing pressostatic regulation

FeaturesUnit for installing inside or outside the room to beair-conditionedMaximum resistance to rust thanks to galvanised sheetmetal structures and panels with powder-coated paintfinish. The panels are lined with sound-insulating material.The reliability of all the components is guaranteed bypartners who are world leaders in their sector.NEW EC INVERTER fans with electronic commutationin order to maximize the energy saving and reducing thenoise emissions.Standard G4 filtering section, F6-F8 optional, underCEN-EN 779 rule with the separation degree 90,1%ASHRAE. The filter is autoestinguishing type.The microprocessor controls all the main functions of theair conditioners; it also controls the operating alarmswith the possibility of interfacing to supervisor andremoteservicing systems.Electrical box under IEC 204-1/EN60204-1 rules.Capillary Pre and After sales service.

Main accessories• Remote user terminal• Electric heating coil• Water heating coil• Humidifier• Air distribution plenum• Sound absorber plenum for air outlet• Interface electronic board• Electronic Thermostatic valve

Unit DescriptionDuctable close control units air-conditioners with capacity ranging from 20 to 100kW for vertical installation and cooling only, with optional heating by means ofheating elements and hot water, optional humidifer and dehumidifier for precisetemperature and humidity control. Particularly suitable for air conditioningtechnological, servers and IT rooms and all technological applications in general.Units fittend with EC INVERTER fans, upflow or downflow.

DUAL FLUID unit has to be connected to an external chiller for PRIMARY circuit.The direct expansion circuit, secondary or BACK-UP circuit, is water cooled and

has to be connected with a remote dry cooler or to city water net.

CommandsEVOLUTIONSemi-graphic display 132 x 64 pixel, Programmable software, Record storage of 100 alarms, General alarm,Automatic reset after blackout, Compressor FIFO management, Integral LAN system, Standby management,Automatic rotation, Serious alarms, Operating contemporaneousness

Close control unit dual fluid, water cooleddirect expansion20-100kW

Page 269: Products Guide V01 - ParagonEfficient project management thanks to Climaveneta as unique project leader. Complete and specialized Organization Climaveneta qualifies itself for the

271

NOTE(1) Indoor air: 24°C/50% r.h.; Water: 30°-35°C(2) Indoor air: 24°C/50% r.h.; Water (in/out): 7/12°C(3) Measured at 1,5 m high and 2m front unit, in open field conditions

Models 20 26 29 39 30 40 50 60 70 80 90

Electrical power supply V-Ph~Hz 400/3+N/50

COOLING PERFORMANCES (DX)

Total cooling capacity (1) kW 24,9 30,6 32,3 47,3 47,3 50 54,5 70,3 76,6 91,8 102

Sensible cooling capacity (1) kW 22,8 28,3 30 46,9 46,9 47,9 50,7 66,8 71,1 88,2 92,2

SHR 0,92 0,92 0,93 0,99 0,99 0,96 0,93 0,95 0,93 0,96 0,90

COMPRESSORS

Quantity n° 1 1 1 1 2 2 2 2 2 2 2

Power abs. kW 4,30 5,40 6,11 6,94 6,44 8,61 10,6 12,3 13,3 16 19,3

N° Circuits n° 1 1 1 1 2 2 2 2 2 2 2

Refrigerant R410A R410A R410A R410A R410A R410A R410A R410A R410A R410A R410A

COOLING PERFORMANCES (CW)

Total cooling capacity (2) kW 23,8 28,1 29,5 50 41 50 51,4 65 67,6 91 91

Sensible cooling capacity (2) kW 21,8 26,4 27,6 46,3 37 46,3 47,5 62,2 64,5 85 85

SHR 0,92 0,94 0,94 0,93 0,90 0,93 0,92 0,96 0,95 0,93 0,93

Water flow rate (2) l/h 3890 4590 4590 8170 6710 8170 8170 10630 10630 14870 14870

Total pressure drop water side (2) kPa 26 35 35 46 30 46 46 26 26 53 53

VENTILATION

Air flow mc/h 6000 7500 8000 13000 10000 13000 13500 18000 19000 24000 24000

N° EC Inverter fans n° 1 1 1 2 2 2 2 3 3 4 4

EC Inverter fans power abs. kW 0,89 1,60 1,80 3,40 2,09 3,40 3,65 4,50 5,20 6,82 6,82

ESP std. Pa 20 20 20 20 20 20 20 20 20 20 20

Sound pressure level (3) dB(A) 56 60 60 64 59 64 64 67 67 67 67

AIR FILTER

Degree filtration G4 G4 G4 G4 G4 G4 G4 G4 G4 G4 G4

HUMIDIFIER

Capacity kg/h 5 5 5 5 5 5 5 8 8 8 8

Power abs. kW 3,75 3,75 3,75 3,75 3,75 3,75 3,75 6 6 6 6

ELECTRICAL HEATERS

Steps 3 3 3 3 3 3 3 3 3 3 3

Power abs. kW 9 9 9 15 15 15 15 18 18 18 18

PLATE CONDENSER

Water flow rate (1) l/h 4780 6190 7204 9650 3720x2 4805x2 6156x2 7370x2 8340x2 19160 21340

Pressure drop (1) kPa 22 35 32 36 26 22 33 36 32 32 40

Water content l 2,50 2,50 3 3,80 2x1,6 2x2,5 2x2,5 2x3 2x3,8 8,53 8,53

DIMENSION

L mm 1000 1000 1000 1550 1550 1550 1550 2100 2100 2650 2650

P mm 790 790 790 790 790 790 790 790 790 790 790

H mm 1980 1980 1980 1980 1980 1980 1980 1980 1980 1980 1980

COUPLING EXTERNAL UNIT

BDC STD/LT/LN 030m 039m 039m 052m 039m 052m 062m 078m 092m 103m 123m

LP

H

ACCURATE AT/STD

Page 270: Products Guide V01 - ParagonEfficient project management thanks to Climaveneta as unique project leader. Complete and specialized Organization Climaveneta qualifies itself for the

272

HPAC

AF 20÷90

Versions

STD base versionMOD_A version with condensing fan speed regulation

FeaturesUnit for installing inside or outside the room to beair-conditionedMaximum resistance to rust thanks to galvanised sheetmetal structures and panels with powder-coated paintfinish. The panels are lined with sound-insulating material.The reliability of all the components is guaranteed bypartners who are world leaders in their sector.NEW EC INVERTER fans with electronic commutationin order to maximize the energy saving and reducing thenoise emissions.Standard G4 filtering section, F6-F8 optional, underCEN-EN 779 rule with the separation degree 90,1%ASHRAE. The filter is autoestinguishing type.The microprocessor controls all the main functions of theair conditioners; it also controls the operating alarmswith the possibility of interfacing to supervisor andremoteservicing systems.Electrical box under IEC 204-1/EN60204-1 rules.Capillary Pre and After sales service.

Main accessories• Remote user terminal• Electric heating coil• Water heating coil• Humidifier• Vibration isolation frame with rubber mountings• Air distribution plenum• Sound absorber plenum for air outlet• Interface electronic board• Electronic Thermostatic valve

Unit DescriptionDuctable close control units air-conditioners with capacity ranging from 20 to 100kW for vertical installation and cooling only, with optional heating by means ofheating elements and hot water, optional humidifer and dehumidifier for precisetemperature and humidity control. Particularly suitable for air conditioningtechnological, servers and IT rooms and all technological applications in general.Units fittend with EC INVERTER fans, upflow or downflow.

FREE-COOLING unit water cooled has to be connected with a remote dry cooler

or an external chiller.

CommandsEVOLUTIONSemi-graphic display 132 x 64 pixel, Programmable software, Record storage of 100 alarms, General alarm,Automatic reset after blackout, Compressor FIFO management, Integral LAN system, Standby management,Automatic rotation, Serious alarms, Operating contemporaneousness

Close control unit free-cooling source,water cooled direct expansion20 - 100 kW

Page 271: Products Guide V01 - ParagonEfficient project management thanks to Climaveneta as unique project leader. Complete and specialized Organization Climaveneta qualifies itself for the

273

NOTE(1) Indoor air: 24°C/50% r.h.; Water: 30°-35°C(2) Indoor air: 24°C/50% r.h.; Water IN: 10°C and water flow of DX mode(3) Measured at 1,5 m high and 2m front unit, in open field conditions

Models 20 26 29 39 30 40 50 60 70 80 90

Electrical power supply V-Ph~Hz 400/3+N/50

COOLING PERFORMANCES (DX)

Total cooling capacity (1) kW 24,9 30,6 32,3 47,3 38,1 50 54,5 70,3 76,6 91,8 102

Sensible cooling capacity (1) kW 22,8 28,3 30 46,9 36,7 47,9 50,7 66,8 71,1 88,2 92,2

SHR 0,92 0,92 0,93 0,99 0,96 0,96 0,93 0,95 0,93 0,96 0,90

COMPRESSORS

Quantity n° 1 1 1 1 2 2 2 2 2 2 2

Power abs. kW 4,40 5,40 6,11 8 6,44 8,61 10,6 12,3 13,3 16 19,3

N° Circuits n° 1 1 1 1 2 2 2 2 2 2 2

Refrigerant R410A R410A R410A R410A R410A R410A R410A R410A R410A R410A R410A

COOLING PERFORMANCES (FC)

Total cooling capacity (2) kW 20 24 25,1 40,8 33,6 41,5 43,8 56,6 58,1 76,7 78,3

Sensible cooling capacity (2) kW 20 24 25,1 40,8 33,6 41,5 43,8 56,6 58,1 76,7 78,3

SHR 1 1 1 1 1 1 1 1 1 1 1

Water flow rate l/h 4900 6330 7002 8430 7380 9810 11954 14360 16133 18120 20830

Total water pressure drop kPa 60 97 69 89 64 84 95 85 91 80 99

PLATE CONDENSER

Water content l 11,8 11,8 11,8 17,9 17 19,1 19,1 25,2 26,8 32,5 32,5

VENTILATION

Air flow mc/h 6000 7500 8000 13000 10000 13000 13500 18000 19000 24000 24000

N° EC Inverter fans n° 1 1 1 2 2 2 2 3 3 4 4

EC Inverter fans power abs. kW 0,89 1,60 1,80 3,40 2,09 3,40 3,65 4,50 5,20 6,82 6,82

ESP std. Pa 20 20 20 20 20 20 20 20 20 20 20

Sound pressure level (3) dB(A) 56 60 60 64 59 64 64 67 67 67 67

AIR FILTER

Degree filtration G4 G4 G4 G4 G4 G4 G4 G4 G4 G4 G4

HUMIDIFIER

Capacity kg/h 5 5 5 5 5 5 5 8 8 8 8

Power abs. kW 3,75 3,75 3,75 3,75 3,75 3,75 3,75 6 6 6 6

ELECTRICAL HEATERS

Steps 3 3 3 3 3 3 3 3 3 3 3

Power abs. kW 9 9 9 15 15 15 15 18 18 18 18

DIMENSION

L mm 1000 1000 1000 1550 1550 1550 1550 2100 2100 2650 2650

P mm 790 790 790 790 790 790 790 790 790 790 790

H mm 1980 1980 1980 1980 1980 1980 1980 1980 1980 1980 1980

COUPLING EXTERNAL UNIT

BDC STD/LT/LN 030m 039m 039m 052m 039m 052m 062m 078m 092m 103m 123m

LP

H

ACCURATE AF/STD

Page 272: Products Guide V01 - ParagonEfficient project management thanks to Climaveneta as unique project leader. Complete and specialized Organization Climaveneta qualifies itself for the

274

HPAC

AC 007÷221

Versions

STD base versionHT for High Density application

FeaturesUnit for installing inside or outside the room to beair-conditioned.Maximum resistance to rust thanks to galvanised sheetmetal structures and panels with powder-coated paintfinish. The panels are lined with sound-insulatingmaterial to limit noise levels.The reliability and functionality of the all parts areguaranteed by partners who are world leaders in theirsector.Double-inlet centrifugal fan per standard installed,directly coupled and suspended on vibration-isolationmountings. The fans are of the forward-bladed type formaximum efficiency and low noise. Available as option,EC INVERTER fans with electronic commutation,Backward Curved Fan type to minimize energyconsumption and noise emission.Standard G2/G4 filtering section, F6-F8 optional, toCEN-EN 779 with average degree of separation 90.1%ASHRAE. The filter is self-extinguishing.The microprocessor controls the mains functions of theconditioning unit, it also controls the operating alarmswith the possibility of interfacing to supervisor andremote-servicing systems.Switchboard to IEC 204-1/EN60204-1Capillary Pre and After sales service.

Main accessories• Remote user terminal• Electric heating coil• Water heating coil• Humidifier• Vibration isolation frame with rubber mountings• Air distribution plenum• Sound absorber plenum for air outlet• Interface electronic board

Unit DescriptionDuctable close control air-conditioners with capacities ranging from 8 to 225 kWfor vertical installation and cooling only, with optional heating by means of heatingelement or hot water, optional humidifier and dehumidifier for precise temperatureand humidity control.Particularly suitable for air-conditioning technological, serverand CED rooms and all technological applications in general. Units fitted withcentrifugal fans with upward airflow from the top or from the bottom. These unitsare provided with 3way valve and servomotor. Unit has to be connected with an

external chiller.

CommandsEVOLUTIONSemi-graphic display 132 x 64 pixel Programmable software, Record storage of 100 alarms, General alarmAutomatic reset after blackout, Integral LAN system Standby management, Automatic rotation, Serious alarms,Operating contemporaneousness

Close control unit chilled water8 - 225 kW

Page 273: Products Guide V01 - ParagonEfficient project management thanks to Climaveneta as unique project leader. Complete and specialized Organization Climaveneta qualifies itself for the

275

NOTE(1) Indoor air: 24°C/50% r.h.; Water (in/out): 7/12°C(5) Measured at 1,5 m high and 2m front unit, in open field conditions

Models 07 09 14 19 25 30 34 41 50

Electrical power supply V-Ph~Hz 400/3+N/50

COOLING PERFORMANCES

Total cooling capacity (1) kW 8,50 10,1 15,7 20,4 28,4 33,8 37,4 48,5 57,7

Sensible cooling capacity (1) kW 8,50 9,50 15,7 19 28,4 30,9 37,4 48,5 52,8

SHR 1 0,94 1 0,93 1 0,91 1 1 0,92

Water flow rate (1) l/h 1390 1660 2570 3330 4640 5520 6110 7930 9430

Total unit pressure drop (1) kPa 33 36 39 60 57 65 46 69 71

N° water circuits n° 1 1 1 1 1 1 1 1 1

FANS

Fan air flow m3/h 2500 2500 4900 4900 8000 8000 13500 13500 13500

N° Centrifugal fans n° 1 1 2 2 1 1 2 2 2

N° EC Inverter fans n° 1 1 2 2 1 1 2 2 2

Centrifugal fans power abs. kW 0,49 0,49 1 1 2,02 2,02 3,61 3,61 3,61

EC Inverter fans power abs. kW 0,27 0,27 0,53 0,53 1,69 1,69 3,51 3,51 3,51

ESP std. Pa 20 20 20 20 20 20 20 20 20

Sound pressure level (2) dB(A) 50 50 53 53 60 60 64 64 64

AIR FILTER

Degree filtration G2 G2 G2 G2 G4 G4 G4 G4 G4

HUMIDIFIER

Capacity kg/h 3 3 5 5 5 5 5 5 5

Power absorbed kW 2,25 2,25 3,75 3,75 3,75 3,75 3,75 3,75 3,75

ELECTRICAL HEATERS

Steps n° 3 3 3 3 3 3 3 3 3

Power absorbed kW 4 4 8 8 9 9 15 15 15

DIMENSION

L mm 600 600 1000 1000 1000 1000 1550 1550 1550

P mm 500 500 500 500 790 790 790 790 790

H mm 1980 1980 1980 1980 1980 1980 1980 1980 1980

Models 060 070 080 090 131 151 171 191 221

Electrical power supply V-Ph~Hz 400/3+N/50

COOLING PERFORMANCES

Total cooling capacity (1) kW 69 82,6 88,7 104 131 155 178 197 225

Sensible cooling capacity (1) kW 69 73,7 88,7 97 106 127 136 156 168

SHR 1 0,89 1 0,93 0,81 0,82 0,77 0,79 0,75

Water flow rate (1) l/h 11280 13500 14500 17050 21650 25530 29290 32350 36610

Total unit pressure drop (1) kPa 71 73 69 74 122 88 105 147 135

N° water circuits n° 1 1 1 1 1 1 1 1 1

FANS

Fan air flow m3/h 19000 19000 25000 25000 25000 30000 30000 36000 36000

N° Centrifugal fans n° 2 2 3 3 3 - - - -

N° EC Inverter fans n° 3 3 4 4 4 3 3 3 3

Centrifugal fans power abs. kW 6,55 6,55 9,42 9,42 9,42 - - - -

EC Inverter fans power abs. kW 5,11 5,11 6,82 6,82 6,82 4,9 4,9 6,7 6,7

ESP std. Pa 20 20 20 20 20 20 20 20 20

Sound pressure level (2) dB(A) 67 67 67 67 67 69 69 70 70

AIR FILTER

Degree filtration G4 G4 G4 G4 G4 G4 G4 G4 G4

HUMIDIFIER

Capacity kg/h 8 8 8 8 8 10 10 15 15

Power absorbed kW 6 6 6 6 6 7,50 7,5 11,3 11,3

ELECTRICAL HEATERS

Steps n° 3 3 3 3 3 3 3 3 3

Power absorbed kW 18 18 18 18 18 24 24 24 24

DIMENSION

L mm 2100 2100 2650 2650 2650 2650 2650 3200 3200

P mm 790 790 790 790 790 890 890 890 890

H mm 1980 1980 1980 1980 1980 2180 2180 2180 2180

ACCURATE AC/STD

Page 274: Products Guide V01 - ParagonEfficient project management thanks to Climaveneta as unique project leader. Complete and specialized Organization Climaveneta qualifies itself for the

276

NOTE(1) Indoor air: 33°C/40% r.h.; Water (in/out): 15/20°C(5) Measured at 1,5 m high and 2m front unit, in open field condition

Models 025 030 034 041 050 060 070 080 090

Electrical power supply V-Ph~Hz 400/3+N/50

COOLING PERFORMANCES

Total cooling capacity (1) kW 30,8 37,1 44,5 52,2 63,2 73,3 87,4 97,4 108

Sensible cooling capacity (1) kW 30,8 37,1 44,5 52,2 63,2 73,3 87,4 97,4 108

SHR 1 1 1 1 1 1 1 1 1

Water flow rate (1) l/h 5320 6410 7654 9020 10920 12670 15100 16830 18660

Total unit pressure drop (1) kPa 50 64 51 51 76 41 46 75 80

N° water circuits n° 1 1 1 1 1 1 1 1 1

FANS

Fan air flow m3/h 8000 8000 13500 13500 13500 19000 19000 25000 25000

N° Centrifugal fans n° 1 1 2 2 2 2 2 3 3

N° EC Inverter fans n° 1 1 2 2 2 3 3 4 4

Centrifugal fans power abs. kW 2,02 2,02 3,61 3,61 3,61 6,55 6,55 9,42 9,42

EC Inverter fans power abs. kW 1,69 1,69 3,51 3,51 3,51 5,11 5,11 6,82 6,82

ESP std. Pa 20 20 20 20 20 20 20 20 20

Sound pressure level (2) dB(A) 60 60 64 64 64 67 67 67 67

AIR FILTER

Degree filtration G4 G4 G4 G4 G4 G4 G4 G4 G4

HUMIDIFIER

Capacity kg/h 5 5 5 5 5 8 8 8 8

Power absorbed kW 3,75 3,75 3,75 3,75 3,75 6 6 6 6

ELECTRICAL HEATERS

Steps n° 3 3 3 3 3 3 3 3 3

Power absorbed kW 9 9 15 15 15 18 18 18 18

DIMENSION

L mm 1000 1000 1550 1550 1550 2100 2100 2650 2650

P mm 790 790 790 790 790 790 790 790 790

H mm 1980 1980 1980 1980 1980 1980 1980 1980 1980

LP

H

ACCURATE AC/HT

Page 275: Products Guide V01 - ParagonEfficient project management thanks to Climaveneta as unique project leader. Complete and specialized Organization Climaveneta qualifies itself for the

277

Page 276: Products Guide V01 - ParagonEfficient project management thanks to Climaveneta as unique project leader. Complete and specialized Organization Climaveneta qualifies itself for the

278

HPAC

AB 020÷140

Versions

STD base version

FeaturesUnit for installing inside or outside the room to beair-conditionedMaximum resistance to rust thanks to galvanised sheetmetal structures and panels with powder-coated paintfinish. The panels are lined with sound-insulating material.The reliability and functionality of the all parts areguaranteed by partners who are world leaders in theirsector.NEW EC INVERTER fans with electronic commutationin order to maximize the energy saving and reducing thenoise emissions.Standard G4 filtering section, F6-F8 optional, underCEN-EN 779 rule with the separation degree 90,1%ASHRAE. The filter is autoestinguishing type.The microprocessor controls the mains functions of theconditioning unit, it also controls the operating alarmswith the possibility of interfacing to supervisor andremote-servicing systems.Electrical box under IEC 204-1/EN60204-1 rules.Capillary Pre and After sales service.

Main accessories• Remote user terminal• Electric heating coil• Water heating coil• Humidifier• Vibration isolation frame with rubber mountings• Air distribution plenum• Sound absorber plenum for air outlet• Interface electronic board

Unit DescriptionDuctable close control units air-conditioners with capacity ranging from 20 to 145kW for vertical installation and cooling only, with optional heating by means ofheating elements and hot water, optional humidifer and dehumidifier for precisetemperature and humidity control. Particularly suitable for air conditioningtechnological, servers and IT rooms and all technological applications in general.Units fittend with EC INVERTER fans, upflow or downflow. These units are providedwith two indipendent chilled water circuits, each one with 3way valve andservomotor. Units has to be connected to 2 complete independent circuit each one

in back-up to the other one.

CommandsEVOLUTIONSemi-graphic display 132 x 64 pixel Programmable software, Record storage of 100 alarms, General alarmAutomatic reset after blackout, Integral LAN system Standby management, Automatic rotation, Serious alarms,Operating contemporaneousness

DUAL COIL close control unit, chilledwater type20 - 145 kW

Page 277: Products Guide V01 - ParagonEfficient project management thanks to Climaveneta as unique project leader. Complete and specialized Organization Climaveneta qualifies itself for the

ACCURATE AB/STD

NOTE(1) Indoor air: 24°C/50% r.h.; Water (in/out): 7/12°C(2) Measured at 1,5 m high and 2m front unit, in open field conditions

Models 020 025 030 040 045 055 060 075 105 120 130 140

Electrical power supply V-Ph~Hz 400/3+N/50

COOLING PERFORMANCES x each circuit

Total cooling capacity (1) kW 22,5 29 41,2 50,5 54,2 66,4 76,6 94,3 105 125 131 148

Sensible cooling capacity (1) kW 22,5 27,7 41,2 47,5 54,2 64,5 76,6 89,9 102 112 128 137

SHR 1,00 0,96 1,00 0,94 1,00 0,97 1,00 0,95 0,98 0,90 0,98 0,92

Water flow rate (1) l/h 3670 4840 6740 8420 8860 11060 12520 15710 17420 20780 21880 24070

Total unit pressure drop (1) kPa 51 72 42 45 38 53 43 52 95 73 55 66

FANS

Fan air flow m3/h 8000 8000 13500 13500 19000 19000 26000 26000 30000 30000 36000 36000

N° EC Inverter fans n° 1 1 2 2 3 3 4 4 3 3 3 3

EC Inverter fans power abs. kW 1,69 1,69 3,51 3,51 5,11 5,11 6,82 6,82 4,9 4,9 6,7 6,7

ESP std. Pa 20 20 20 20 20 20 20 20 20 20 20 20

Sound pressure level (2) dB(A) 60 60 64 64 67 67 67 67 69 69 70 70

AIR FILTER

Degree filtration G4 G4 G4 G4 G4 G4 G4 G4 G4 G4 G4 G4

HUMIDIFIER

Capacity kg/h 5 5 5 5 8 8 8 8 10 10 15 15

Power absorbed kW 3,75 3,75 3,75 3,75 6 6 6 6 7,50 7,50 11,3 11,3

ELECTRICAL HEATERS

Steps n° 3 3 3 3 3 3 3 3 3 3 3 3

Power absorbed kW 9 9 15 15 18 18 18 18 24 24 24 24

DIMENSION

L mm 1000 1000 1550 1550 2100 2100 2650 2650 2650 2650 3200 3200

P mm 790 790 790 790 790 790 790 790 890 890 890 890

H mm 1980 1980 1980 1980 1980 1980 1980 1980 2180 2180 2180 2180

LP

H

279

Page 278: Products Guide V01 - ParagonEfficient project management thanks to Climaveneta as unique project leader. Complete and specialized Organization Climaveneta qualifies itself for the

280

HPAC

BRE 014m÷116b

Versions

STD base versionLN low noise versionLT low outdoor temperature version

Features

ELECTRIC FANS of an axial type, statically anddynamically balanced on two levels, with blades in aninoxidable material and external rotor motor suitable foradjusting the speed, all mounted on a metal supportinggrid in conformity with safety regulations. The motors areto VDE 0530-12.84. The protection rating is IP54 toDIN40050.

CONDENSING COIL: the combination of innovativecorrugated fins with the use of smooth pipes on theexchanger ensures excellent heat transfer with aminimum amount of fluid. The heat exchangers consistof aluminium fins and copper pipes.

REFRIGERANT CIRCUIT CONNECTIONS arearranged along one side of the unite and are to bewelded for safe connection that prevents any fluid leak.

Main accessories• Legs kit for vertical air flow installation• Epoxy coated (for fins only)• Cataphoresys coil treatment• Copper-Copper coil

Unit DescriptionRemote condensers with axial-type fan(s) for outdoor installation. Installation maybe vertical with a horizontal air outflow or, using special brackets, horizontal with anupward air outflow. The very low noise, adjustable-speed fans are excellent for usein both technological and civil applications. BRC-BRE units operate with a single-phase 230/1/50 power supply totally independent and separate from the indoorunit ACCURATE. These condensing units are therefore also suited for use withoutbeing directly connected to indoor units. BRC-BRE units are not provided withintegrated fans speed regulator per standard. However, CLIMAVENETA can providesuch fans speed regulator as OPTIONAL, by installing it directly inside the indoorunit ACCURATE.

Remote condenser with axial fans

Page 279: Products Guide V01 - ParagonEfficient project management thanks to Climaveneta as unique project leader. Complete and specialized Organization Climaveneta qualifies itself for the

281

NOTE(1) Ext. air 35°C; T = 13°K(2) Sound pressure measured at 10 m in open field conditions(3) Without legs kit configuration; horizontal air flow

Models 014m 022m 027m 044m 051m 054b 065b 076b 100b 116b

NOMINAL CHARACTERISTICS

Nominal capacity (1) kW 13,4 21,7 26,6 43,5 50,4 53,3 65,1 76,2 100 116

Total power input kW 0,27 0,60 0,60 1,20 1,20 1,20 1,80 1,80 2,40 3

Electrical power supply V-Ph~Hz 230/1/50 230/1/50 230/1/50 230/1/50 230/1/50 230/1/50 230/1/50 230/1/50 230/1/50 230/1/50

Net weight kg 72 85 102 137 153 167 191 213 302 339

VENTILATION

Air flow m3/h 5000 8200 7200 16400 15200 14400 24600 22800 28800 38000

Sound pressure level (2) dB(A) 40 46 46 49 49 49 51 51 52 53

DIMENSION (3)

L mm 1240 1360 1360 2360 2360 2360 3360 3360 4360 5360

P mm 494 580 580 580 580 580 580 580 580 580

H mm 764 1070 1070 1070 1070 1070 1070 1070 1070 1070

BRE / STD

NOTE(1) Ext. air 35°C; T = 13°K(2) Sound pressure measured at 10 m in open field conditions(3) Without legs kit configuration; horizontal air flow

Models 014m 022m 027m 044m 051m 054b 065b 076b 100b 116b

NOMINAL CHARACTERISTICS

Nominal capacity (1) kW 14,1 20 28,2 42,3 50 55,3 73,1 75,5 99,1 118

Total power input kW 0,33 0,26 0,66 0,99 0,99 0,99 1,32 1,32 1,65 2,52

Electrical power supply V-Ph~Hz 230/1/50 230/1/50 230/1/50 230/1/50 230/1/50 230/1/50 230/1/50 230/1/50 230/1/50 230/1/50

Net weight kg 85 125 137 191 213 235 276 302 339 397

VENTILATION

Air flow m3/h 6000 6500 12000 18000 16500 16000 22000 20300 27050 28560

Sound pressure level (2) dB(A) 37 35 39 41 41 41 42 42 43 43

DIMENSION (3)

L mm 1360 2120 2360 3360 3360 3360 4360 4360 5360 5560

P mm 580 494 580 580 580 580 580 580 580 615

H mm 1070 764 1070 1070 1070 1070 1070 1070 1070 1070

BRE / LN

NOTE(1) Ext. air 35°C; T = 13°K(2) Sound pressure measured at 10 m in open field conditions(3) Without legs kit configuration; horizontal air flow

Models 014m 022m 027m 044m 051m 054b 065b 076b 100b 116b

NOMINAL CHARACTERISTICS

Nominal capacity (1) kW 13,4 21,7 26,6 43,5 50,4 53,3 65,1 76,2 100 116

Total power input kW 0,27 0,60 0,60 1,20 1,20 1,20 1,80 1,80 2,40 3

Electrical power supply V-Ph~Hz 230/1/50 230/1/50 230/1/50 230/1/50 230/1/50 230/1/50 230/1/50 230/1/50 230/1/50 230/1/50

Net weight kg 72 85 102 137 153 167 191 213 302 339

VENTILATION

Air flow m3/h 5000 8200 7200 16400 15200 14400 24600 22800 28800 38000

Sound pressure level (2) dB(A) 40 46 46 49 49 49 51 51 52 53

DIMENSION (3)

L mm 1240 1360 1360 2360 2360 2360 3360 3360 4360 5360

P mm 494 580 580 580 580 580 580 580 580 580

H mm 764 1070 1070 1070 1070 1070 1070 1070 1070 1070

BRE / LT

P

H

L

Page 280: Products Guide V01 - ParagonEfficient project management thanks to Climaveneta as unique project leader. Complete and specialized Organization Climaveneta qualifies itself for the

282

HPAC

BRC 014m÷120b

Versions

STD base versionLN low noise versionLT low outdoor temperature version

Features

HOUSING: designed to allowed easy access to internalcomponents, is made from prepainted galvanized sheetsteel, and it:• offers hight corrosion strenght and impact resistence;• is resistant at low temperatures;• is non toxic;• does not produce polluting debris;• is completely covered in a protective plastic film.

ELECTRIC FANS of an axial type, statically anddynamically balanced on two levels, with blades in aninoxidable material and external rotor motor suitable foradjusting the speed, all mounted on a metal supportinggrid in conformity with safety regulations. The motors areto VDE 0530-12.84. The protection rating is IP54 toDIN40050.

CONDENSING COIL: the combination of innovativecorrugated fins with the use of smooth pipes on theexchanger ensures excellent heat transfer with aminimum amount of fluid. The heat exchangers consistof aluminium fins and copper pipes.

REFRIGERANT CIRCUIT CONNECTIONS arearranged along one side of the unite and are to bewelded for safe connection that prevents any fluid leak.ISOLATING SWITCH, contained in an electric box withprotection rating IP54, with switch control accessiblefrom the outside and connecting terminals.

Main accessories• Legs kit for vertical air flow installation• Epoxy coated (for fins only)• Cataphoresys coil treatment• Copper-Copper coil

Unit DescriptionRemote condensers with axial-type fan(s) for outdoor installation. Installation maybe vertical with a horizontal air outflow or, using special brackets, horizontal with anupward air outflow. The very low noise, adjustable-speed fans are excellent for usein both technological and civil applications. BRC-BRE units operate with a single-phase 230/1/50 power supply totally independent and separate from the indoorunit ACCURATE. These condensing units are therefore also suited for use withoutbeing directly connected to indoor units. BRC-BRE units are not provided withintegrated fans speed regulator per standard. However, CLIMAVENETA can providesuch fans speed regulator as OPTIONAL, by installing it directly inside the indoorunit ACCURATE.

Remote condenser with axial fans

Page 281: Products Guide V01 - ParagonEfficient project management thanks to Climaveneta as unique project leader. Complete and specialized Organization Climaveneta qualifies itself for the

283

NOTE(1) Ext. air 35°C; T = 15°K(2) Sound pressure measured at 10 m in open field conditions(3) Without legs kit configuration; horizontal air flow

Models 014m 025m 032m 051b 052m 077b 088b 093b 102b 120b

NOMINAL CHARACTERISTICS

Nominal capacity (1) kW 14 26 32 52 52 77 90 93 102 120

Total power input kW 0,28 0,60 0,60 1,20 1,20 1,80 1,80 1,80 2,40 2,40

Electrical power supply V-Ph~Hz 230/1/50 230/1/50 230/1/50 230/1/50 230/1/50 230/1/50 230/1/50 230/1/50 230/1/50 230/1/50

Net weight kg 45 90 110 167 167 239 253 293 320 337

VENTILATION

Air flow m3/h 4410 8780 7870 17560 17560 26340 25230 23610 35120 33640

Sound pressure level (2) dB(A) 41 48 48 51 51 53 53 53 54 54

DIMENSION (3)

L mm 1175 1325 1325 2425 2425 3525 3525 3525 4625 4625

P mm 510 630 630 630 630 630 630 630 630 630

H mm 872 1168 1168 1168 1168 1168 1168 1168 1168 1168

BRC / STD

NOTE(1) Ext. air 35°C; T = 15°K(2) Sound pressure measured at 10 m in open field conditions(3) Without legs kit configuration; horizontal air flow

Models 014m 025m 032m 051b 052m 077b 088b 093b 102b 120b

NOMINAL CHARACTERISTICS

Nominal capacity (1) kW 13 22 42 48 48 72 76 85 95 101

Total power input kW 0,13 0,33 0,66 0,66 0,66 0,99 0,99 1,32 1,32 1,32

Electrical power supply V-Ph~Hz 230/1/50 230/1/50 230/1/50 230/1/50 230/1/50 230/1/50 230/1/50 230/1/50 230/1/50 230/1/50

Net weight kg 50 90 110 177 177 253 293 320 337 391

VENTILATION

Air flow m3/h 2930 6410 12820 12160 12160 18240 17340 25640 24320 23400

Sound pressure level (2) dB(A) 33 38 41 41 41 43 43 44 44 44

DIMENSION (3)

L mm 1175 1325 2425 2425 2425 3525 3525 4625 4625 4625

P mm 510 630 630 630 630 630 630 630 630 630

H mm 872 1168 1168 1168 1168 1168 1168 1168 1168 1168

BRC / LN

NOTE(1) Ext. air 35°C; T = 15°K(2) Sound pressure measured at 10 m in open field conditions(3) Without legs kit configuration; horizontal air flow

Models 014m 025m 032m 051b 052m 077b 088b 093b 102b 120b

NOMINAL CHARACTERISTICS

Nominal capacity (1) kW 14 26 32 52 52 77 90 93 102 120

Total power input kW 0,28 0,60 0,60 1,20 1,20 1,80 1,80 1,80 2,40 2,40

Electrical power supply V-Ph~Hz 230/1/50 230/1/50 230/1/50 230/1/50 230/1/50 230/1/50 230/1/50 230/1/50 230/1/50 230/1/50

Net weight kg 45 90 110 167 167 239 253 293 320 337

VENTILATION

Air flow m3/h 4410 8780 7870 17560 17560 26340 25230 23610 35120 33640

Sound pressure level (2) dB(A) 41 48 48 51 51 53 53 53 54 54

DIMENSION (3)

L mm 1175 1325 1325 2425 2425 3525 3525 3525 4625 4625

P mm 510 630 630 630 630 630 630 630 630 630

H mm 872 1168 1168 1168 1168 1168 1168 1168 1168 1168

BRC / LT

P

H

L

Page 282: Products Guide V01 - ParagonEfficient project management thanks to Climaveneta as unique project leader. Complete and specialized Organization Climaveneta qualifies itself for the

284

HPAC

ARCC M1D÷M4F_B

Versions

STD base version

Features

CONDENSING COIL with high efficiency made byinnovative corrugated fins and copper pipes withgrooved internal surface.FANS with double-inlet, with vibration-isolationmountings, with protection rating IP44 and insulationclass F.

Main accessories• Legs kit for vertical air flow installation• Copper-Copper coil

Unit DescriptionCondensing unit with centrifugal fan with very low noise level are excellent for use inboth technological and civil applications, designed for ductable installation with maxESP 150Pa. The possibility to remove the side panel made easier the cleaningoperation and the air flow configuration. The ARCC units operate with a230V/1/50Hz and 400V/3+N/50Hz power supply totally independent and separatefrom the indoor unit ACCURATE. These units are therefore also suited for usewithout being directly connected to indoor units.

Remote condenser with centrifugal fans

Page 283: Products Guide V01 - ParagonEfficient project management thanks to Climaveneta as unique project leader. Complete and specialized Organization Climaveneta qualifies itself for the

285

NOTE(1) Ext. Air 35°C; T =15°K(2) ESP=100Pa(3) Sound pressure measured at 10 m in open field conditions(4) Without legs kit configuration; horizontal air flow

Models M1D M2B M2C M2D M3C M3D M2E

NOMINAL CHARACTERISTICS

Nominal capacity (1) kW 14 18 22 28 33 42 55

Total power input kW 0,525 1,1 1,05 1,50 1,575 1,575 2,76

Electrical power supply V-Ph~Hz 230/1/50 230/1/50 230/1/50 230/1/50 230/1/50 230/1/50 400/3+N/50

Net weight kg 87 83 121 135 162 183 188

VENTILATION

Air flow (2) m3/h 3230 4560 7040 6460 10560 9690 13120

Sound pressure level (3) dB(A) 35 38 37 37 39 39 46

DIMENSION (4)

L mm 760 1020 1360 1360 1960 1960 2060

P mm 950 800 845 845 845 845 845

H mm 845 520 950 950 950 950 950

ARCC / STD

Models M3D_B M2E_B M3G_B M3E_B M3F_B M4E_B M4F_B

NOMINAL CHARACTERISTICS

Nominal capacity (1) kW 42 55 66 82,5 87 110 116

Total power input kW 1,575 2,76 4,14 4,14 4,14 5,52 5,52

Electrical power supply V-Ph~Hz 230/1/50 400/3+N/50 400/3+N/50 400/3+N/50 400/3+N/50 400/3+N/50 400/3+N/50

Net weight kg 183 188 216 266 293 344 378

VENTILATION

Air flow (2) m3/h 9690 13120 17490 19680 18570 26240 24760

Sound pressure level (3) dB(A) 39 46 48 48 48 49 49

DIMENSION (4)

L mm 1960 2060 1960 3010 3010 3960 3960

P mm 845 845 845 845 845 845 845

H mm 950 950 950 950 950 950 950

LP

H

Page 284: Products Guide V01 - ParagonEfficient project management thanks to Climaveneta as unique project leader. Complete and specialized Organization Climaveneta qualifies itself for the

286

HPAC

BDC 013m÷123m

Versions

STD base versionLN low noise versionLT low outdoor temperature version

Features

HOUSING: designed to allowed easy access to internalcomponents, is made from prepainted galvanized sheetsteel, and it:• offers hight corrosion strenght and impact resistence;• is resistant at low temperatures;• is non toxic;• does not produce polluting debris;• is completely covered in a protective plastic film.

ELECTRIC FANS of an axial type, statically anddynamically balanced on two levels, with blades in aninoxidable material and external rotor motor suitable foradjusting the speed, all mounted on a metal supportinggrid in conformity with safety regulations. The motors areto VDE 0530-12.84. The protection rating is IP54 toDIN40050.

HEAT EXCHANGER: the combination of innovativecorrugated fins with the use of smooth pipes on theexchanger ensures excellent heat transfer with aminimum amount of fluid. The heat exchangers consistof aluminium fins and copper pipes.

HYDRAULICS CIRCUIT CONNECTIONS are arrangedalong one side of the unite and are to be welded for safeconnection that prevents any fluid leak.

ISOLATING SWITCH, contained in an electric box withprotection rating IP54, with switch control accessiblefrom the outside and connecting terminals.

Main accessories• Legs kit for vertical air flow installation• Epoxy coated (for fins only)• Cataphoresys coil treatment• Copper-Copper coil

Unit DescriptionDry Cooler with axial-type fan(s) for outdoor installation. Installation may be verticalwith a horizontal air outflow or, using special brackets, horizontal with an upward airoutflow. The very low noise, adjustable-speed fans are excellent for use in bothtechnological and civil applications. BDC units operate with a single-phase230/1/50 power supply totally independent and separate from the indoor unitACCURATE. These units are therefore also suited for use without being directlyconnected to indoor units. BDC units are not provided with integrated fans speedregulator per standard. However, CLIMAVENETA can provide such fans speedregulator as OPTIONAL, by installing it directly inside the indoor unit ACCURATE.

Dry Cooler

Page 285: Products Guide V01 - ParagonEfficient project management thanks to Climaveneta as unique project leader. Complete and specialized Organization Climaveneta qualifies itself for the

287

NOTE(1) Water temp.: 35/30°C; Ext. Temp.: 24°C(2) Sound pressure measured at 10 m in open field conditions(3) Without legs kit configuration; horizontal air flow

Models 013m 030m 039m 052m 062m 078m 092m 103m 123m

NOMINAL CHARACTERISTICS

Nominal capacity (1) kW 17 33 40,5 61 68 83 98,5 121 135

Total power input kW 0,60 1,20 1,20 1,80 1,80 2,40 3,60 3,60 3,60

Electrical power supply V-Ph~Hz 230/1/50 230/1/50 230/1/50 230/1/50 230/1/50 230/1/50 230/1/50 230/1/50 230/1/50

Net weight kg 90 167 177 253 293 337 490 519 601

VENTILATION

Air flow m3/h 8780 17560 16820 25230 23610 33640 52680 50460 47220

Sound pressure level (2) dB(A) 48 51 51 53 53 54 56 56 56

DIMENSION (3)

L mm 1325 2425 2425 3525 3525 4625 3658 3658 3658

P mm 630 630 630 630 630 630 760 760 760

H mm 1168 1168 1168 1168 1168 1168 2286 2286 2286

BDC / STD

NOTE(1) Water temp.: 35/30°C; Ext. Temp.: 24°C(2) Sound pressure measured at 10 m in open field conditions(3) Without legs kit configuration; horizontal air flow

Models 013m 030m 039m 052m 062m 078m 092m 103m 123m

NOMINAL CHARACTERISTICS

Nominal capacity (1) kW 14 32 40,5 54 65,5 82 96 107 129

Total power input kW 0,33 0,66 0,99 1,32 1,32 1,65 1,98 2,64 2,64

Electrical power supply V-Ph~Hz 230/1/50 230/1/50 230/1/50 230/1/50 230/1/50 230/1/50 230/1/50 230/1/50 230/1/50

Net weight kg 90 177 239 320 337 363 519 640 675

VENTILATION

Air flow m3/h 6410 12160 19230 25640 24320 30400 36480 51280 48640

Sound pressure level (2) dB(A) 38 41 43 44 44 45 46 47 47

DIMENSION (3)

L mm 1325 2425 3525 4625 4625 5725 3658 4758 4758

P mm 630 630 630 630 630 630 760 760 760

H mm 1168 1168 1168 1168 1168 1168 2286 2286 2286

BDC / LN

NOTE(1) Water temp.: 35/30°C; Ext. Temp.: 24°C(2) Sound pressure measured at 10 m in open field conditions(3) Without legs kit configuration; horizontal air flow

Models 013m 030m 039m 052m 062m 078m 092m 103m 123m

NOMINAL CHARACTERISTICS

Nominal capacity (1) kW 17 33 40,5 61 68 83 98,5 121 135

Total power input kW 0,601,20 1,20 1,80 1,80 2,40 3,60 3,60 3,60

Electrical power supply V-Ph~Hz 230/1/50 230/1/50 230/1/50 230/1/50 230/1/50 230/1/50 230/1/50 230/1/50 230/1/50

Net weight kg 90 167 177 253 293 337 490 519 601

VENTILATION

Air flow m3/h 8780 17560 16820 25230 23610 33640 52680 50460 47220

Sound pressure level (2) dB(A) 48 51 51 53 53 54 56 56 56

DIMENSION (3)

L mm 1325 2425 2425 3525 3525 4625 3658 3658 3658

P mm 630 630 630 630 630 630 760 760 760

H mm 1168 1168 1168 1168 1168 1168 2286 2286 2286

BDC / LT

P

H

L

Page 286: Products Guide V01 - ParagonEfficient project management thanks to Climaveneta as unique project leader. Complete and specialized Organization Climaveneta qualifies itself for the

288

AACKAKAACKAAA

Page 287: Products Guide V01 - ParagonEfficient project management thanks to Climaveneta as unique project leader. Complete and specialized Organization Climaveneta qualifies itself for the

289

AGEDpackaged

packag

ed

Page 288: Products Guide V01 - ParagonEfficient project management thanks to Climaveneta as unique project leader. Complete and specialized Organization Climaveneta qualifies itself for the

290

Main accessoriesHigh efficiency filters: electronic or rigid pocket F7

Enthalpy free-cooling

CO2 control sensor for air quality

Hot gas post heating

Remote keyboard (distance to 200m and to 500m)

Set-up for remote connectivity with ModBus/Echelon protocol cards

FeaturesREFRIGERANT GAS R410A

The use of R410A has resulted in units offering better energy efficiency in full respect for the environment (ODP = 0).

COMFORT

The wide working field and the accurate design of the unit ensure optimum capacities and guaranty comfort, with a continuous and constant bringing in of thermal load also in the more onerous thermohygrometric conditions.

SAFE USE

The refrigerant piping and the regulation devices are put in suitable space, splitted from the air treatment section. This means a lower accidental risk to contaminate the indoor environment and moreover allowing the thermostatic valve adjustment while the unit is on.

ConfigurationsB base function

AX function with exhaust air axial fan

CE function with return air centrifugal fan

VersionsB base version

CommandsAIR3000The controller AIR3000 offers advanced functions and algorithms. The keypad is generously sized with full operating status display. The controls and detailed LCD make access to unit settings easy and safe. Temperature regulation is based on step-wise proportional logic referring to the return air temperature. The diagnostics includes full management of alarms with the black-box and alarm logging functions for enhanced analysis of the unit operation. Supervision can be easily developed via proprietary devices or the integration in third party systems by means of the most common protocols as ModBus, Echelon LonWorks. Compatibility with the remote keyboard managing up to 10 units. Availability of an internal real time clock for operation scheduling (4-day profiles with 10 hour belts). The defrost adopts a proprietary self-adaptive logic, which features the monitoring of numerous operational parameters. This allows to reduce the number and duration of the defrost cycles, with a benefit for the overall energy efficiency.

Packaged

WORK 0101÷0602

Reversible rooftop unit, for medium crowding applications

37,4 - 198 kWUnit DescriptionUnit for outdoor installation, reversible and direct expansion for the air conditioning, with scroll compressors running on R410A, prepainted panelling with internal thermic insulating and soundproofing material, top frame made with Alloy, basement made from hot-galvanised, centrifugal supply fan section, free-cooling, Exhaust Air thermodynamic effect. Efficiency, Plug&Play approach, an intuitive and comprehensive electronic controller are the leading features of this unit. It is designed to obtain extreme compactness, simplified on-site installations and maintainance and a reduction in their associated costs. All the same, it is guaranteed the best air treatment quality, thanks to the R-410A refrigerant use, the Exhaust Air thermodynamic effect and the optional high efficiency filters.

Page 289: Products Guide V01 - ParagonEfficient project management thanks to Climaveneta as unique project leader. Complete and specialized Organization Climaveneta qualifies itself for the

291

Minimum clearance required0101-0602

Switchboard side mm 1500Condensation coil side mm 2000

Note:

1 Cooling: Outdoor 35°C 50% R.H. / Indoor 26°C 52% R.H. / Mix 30%

2 Heating: Outdoor 7°C 87% R.H. / Indoor 20°C 50% R.H. / Mix 30%

3 ESP for standard configuration (optional accessories not included/calculated)

4 Sound power on the basis of measurements made in compliance with ISO 3744.

5 Unit in standard configuration/execution, without optional accessories

WORK / BModels 0101 0121 0152 0182 0202 0252 0302 0352 0402 0452 0502 0552 0602COOLING ONLYCooling capacity (1) kW 37,4 45,9 53,2 60,3 70,4 86,4 100 115 132 143 166 182 198Sensible cooling capacity (1) kW 27,9 33,5 38,3 44,2 51,2 63,3 72,3 84,3 97 105 122 132 144Compressor power input (1) kW 7,70 10,5 13,1 16,1 17,5 23,3 27,2 32 35,3 40,6 44,7 49,5 54,7HEATING ONLYHeating capacity (2) kW 35,7 44,4 50,3 56,9 66 83,8 91,4 108 127 138 156 175 194Compressors power input (2) kW 7 9,20 10,2 12,4 13,5 18,1 19,3 23,8 28,2 31,7 32,1 37,5 42,4OUTLET FANSSupply air flow rate m3/h 6000 8000 9000 10000 11500 15000 17000 20000 23000 25500 29500 30500 33000Useful static head (3) Pa 250 250 250 250 250 250 250 250 250 250 250 250 250Power Input kW 1,57 2,49 3,18 3,97 2,96 5,46 5,68 7,90 6,90 8,31 10,9 11,8 14,2COMPRESSORSNo. Compressors/No. Circuits N. 1 / 1 1 / 1 2 / 1 2 / 1 2 / 1 2 / 1 2 / 1 2 / 1 2 / 1 2 / 1 2 / 1 2 / 1 2 / 1NOISE LEVELSSound power (4) dB(A) 82 83 86 87 87 87 88 89 90 91 91 91 92SIZEA (5) mm 2175 2175 2175 2175 3145 3145 3145 3145 4600 4600 4600 4600 4600B (5) mm 2250 2250 2250 2250 2250 2250 2250 2250 2250 2250 2250 2250 2250H (5) mm 2410 2410 2410 2410 2410 2410 2410 2410 2410 2410 2410 2410 2410Operating weight (5) kg 1050 1060 1110 1130 1530 1550 1600 1660 2360 2370 2380 2440 2470

COOLINGHEATINGFREE COOLING

r HFCR-410A

SCROLLAXIALCENTRIFUGALTHERMODYNAMIC

Page 290: Products Guide V01 - ParagonEfficient project management thanks to Climaveneta as unique project leader. Complete and specialized Organization Climaveneta qualifies itself for the

292

Main accessoriesEnthalpy free-cooling

CO2 control sensor for air quality

Hot gas post heating

Set-up for remote connectivity with ModBus/Echelon protocol cards

Remote keyboard (distance to 200m and to 500m)

High efficiency filters: electronic or rigid pocket F7

FeaturesREFRIGERANT GAS R410A

The use of R410A has resulted in units offering better energy efficiency in full respect for the environment (ODP = 0).

COMFORT

The wide working field and the accurate design of the unit ensure optimum capacities and guaranty comfort, with a continuous and constant bringing in of thermal load also in the more onerous thermohygrometric conditions.

SAFE USE

The refrigerant piping and the regulation devices are put in suitable space, splitted from the air treatment section. This means a lower accidental risk to contaminate the indoor environment and moreover allowing the thermostatic valve adjustment while the unit is on.

ConfigurationsB base function

AX function with exhaust air axial fan

CE function with return air centrifugal fan

VersionsB base version

CommandsAIR3000The controller AIR3000 offers advanced functions and algorithms. The keypad is generously sized with full operating status display. The controls and detailed LCD make access to unit settings easy and safe. Temperature regulation is based on step-wise proportional logic referring to the return air temperature. The diagnostics includes full management of alarms with the black-box and alarm logging functions for enhanced analysis of the unit operation. Supervision can be easily developed via proprietary devices or the integration in third party systems by means of the most common protocols as ModBus, Echelon LonWorks. Compatibility with the remote keyboard managing up to 10 units. Availability of an internal real time clock for operation scheduling (4-day profiles with 10 hour belts).

Packaged

WORK-T 0101÷0602

Cooling only rooftop unit, for medium crowding applications

34,7 - 200 kWUnit DescriptionUnit for outdoor installation, cooling-only and direct expansion for the air conditioning, with scroll compressors running on R410A, prepainted panelling with internal thermic insulating and soundproofing material, top frame made with Alloy, basement made from hot-galvanised, centrifugal supply fan section, free-cooling, Exhaust Air thermodynamic effect. Efficiency, Plug&Play approach, an intuitive and comprehensive electronic controller are the leading features of this unit. It is designed to obtain extreme compactness, simplified on-site installations and maintainance and a reduction in their associated costs. All the same, it is guaranteed the best air treatment quality, thanks to the R-410A refrigerant use, the exhaust air thermodynamic effect and the optional high efficiency filters.

Page 291: Products Guide V01 - ParagonEfficient project management thanks to Climaveneta as unique project leader. Complete and specialized Organization Climaveneta qualifies itself for the

293

Minimum clearance required0101-0602

Switchboard side mm 1500Condensation coil side mm 2000

Note:

1 Cooling: Outdoor 35°C 50% R.H. / Indoor 26°C 52% R.H. / Mix 30%

2 ESP for standard configuration (optional accessories not included/calculated)

3 Sound power on the basis of measurements made in compliance with ISO 3744.

4 Unit in standard configuration/execution, without optional accessories

WORK-T / BModels 0101 0121 0152 0182 0202 0252 0302 0352 0402 0452 0502 0552 0602COOLING ONLYCooling capacity (1) kW 34,7 43,1 51,7 60,5 70,6 86,6 100 115 133 143 167 182 200Sensible cooling capacity (1) kW 25,9 32,9 37,4 44,2 51,2 63,3 72,3 84,3 96,2 105 122 132 145Compressor power input (1) kW 9 11,8 13,8 16 17,4 23,2 27 31,9 35,1 40,4 44,5 49,3 53,9OUTLET FANSSupply air flow rate m3/h 6000 8000 9000 10000 11500 15000 17000 20000 23000 25500 29500 30500 33000Available static pressure (2) Pa 250 250 250 250 250 250 250 250 250 250 250 250 250Power Input kW 1,57 2,49 3,18 3,97 1,48 2,73 2,84 3,95 2,30 2,77 3,63 3,94 4,73COMPRESSORSNo. Compressors/No. Circuits N. 1 / 1 1 / 1 2 / 1 2 / 1 2 / 1 2 / 1 2 / 1 2 / 1 2 / 1 2 / 1 2 / 1 2 / 1 2 / 1NOISE LEVELSSound power (3) dB(A) 82 83 86 87 87 87 88 89 90 91 91 91 92SIZEA (4) mm 1175 1175 1175 1175 3145 3145 3145 3145 4600 4600 4600 4600 4600B (4) mm 2250 2250 2250 2250 2250 2250 2250 2250 2250 2250 2250 2250 2250H (4) mm 2410 2410 2410 2410 2410 2410 2410 2410 2410 2410 2410 2410 2410Operating weight (4) kg 1050 1060 1110 1130 1530 1550 1600 1660 2360 2370 2380 2440 2470

COOLINGFREE COOLING

r HFCR-410A

SCROLLAXIALCENTRIFUGALTHERMODYNAMIC

Page 292: Products Guide V01 - ParagonEfficient project management thanks to Climaveneta as unique project leader. Complete and specialized Organization Climaveneta qualifies itself for the

294

Main accessoriesHot gas post heating

CO2 control sensor for air quality

High efficiency filters: electronic or rigid pocket F7

Enthalpy free-cooling

Set-up for remote connectivity with ModBus/Echelon protocol cards

Remote keyboard (distance to 200m and to 500m)

FeaturesVARIABLE AIRFLOW FOR AIR TREATMENT SECTION

The specific VAir function is used to deliver air according to the flow of hot-cold air and many other operating parameters. This offers significant reductions in the power input of the fans.

HIGH ENERGY EFFICIENCY

The use of the R410A gas conjoined to the elevated thermodynamic recovery degree of the energy contained in the exhaust air guarantee a high efficiency during the operation.

PLUG-FAN VENTILATION

The plug-fan supply and return fan section matchs the high efficacy ventilation with a quicker and easier electric and aerolics installation of the unit.

SAFE USE

The wide working field and the accurate design of the unit ensure optimum capacities and guaranty comfort, with a continuous and constant bringing in of thermal load also in the more onerous thermohygrometric conditions.

VersionsB base version

CommandsAIR3000SEThe AIR3000SE controller offers advanced functions and algorithms. The keypad features functional controls and a complete LCD display that allows assessment and intervention on the unit by means of a multi-level menu with selectable user´s language. The presence of the programmable timer allows the creation of an operating profile containing up to 4 typical days and 10 time bands. The proportional step heat adjustment is based on the return temperature; proportional-integral adjustment can also be set. Functions include adjustment of available resources, ambient humidity, thermal or enthalpic (optional) free-cooling and delivery temperature limitation. Defrosting is based on a self-adaptive propriety logic with monitoring of many operating and environmental parameters. The specific VAir function is used to deliver air according to the flow of hot-cold air and many other operating parameters. This offers significant reductions in the power input of the fans. The function can be selected from a parameter, it operates within settable flow values and is compatible with the adjusted rotation speed, adjusted flow and adjusted pressure ventilation methods. It also guarantees any differences required between return and delivery airflows. The diagnostics comprises a complete alarm management system, including black box (via PC) functions and an alarm log (via display or also PC) for optimised analysis of unit performance. Supervision can be easily developed via proprietary devices or the integration in third party systems by means of the most common protocols as ModBus, Bacnet, Bacnet-over-IP, Echelon LonWorks protocols. Compatibility with the remote keyboard managing up to 10 units.

Packaged

WHISPER 0102÷0604

High efficiency reversible rooftop unit, for medium crowding applications

35,7 - 197 kWUnit DescriptionAutonomous rooftop unit, air/air reversible, for the thermohygrometric treatment, the filtration and the air change in wide areas. Both winter and summer operating conditions, double refrigerant circuit, scroll compressors with refrigerant R410A. Direct expansion finned external exchangers with thermodynamic effect on the exhaust air. Air treatment section with plug-fans and direct expansion finned internal exchangers. Management of air treatment section according to the requested heating or cooling capacity by the Vair function.

Page 293: Products Guide V01 - ParagonEfficient project management thanks to Climaveneta as unique project leader. Complete and specialized Organization Climaveneta qualifies itself for the

295

Minimum clearance required0102-0604

Switchboard side mm 1500Condensation coil side mm 2000

Note:

1 Cooling: Outdoor 35°C 50% R.H. / Indoor 27°C 47% R.H. / Mix 30%

2 Heating: Outdoor 7°C 87% R.H. / Indoor 20°C 50% R.H. / Mix 30%

3 ESP for standard configuration (optional accessories not included/calculated)

4 Sound power on the basis of measurements made in compliance with ISO 3744.

WHISPER / BModels 0102 0122 0152 0182 0202 0252 0302 0352 0364 0404 0454 0504 0604COOLING ONLYCooling capacity (1) kW 35,7 45 52,3 60,7 73,1 94,5 103 122 125 139 153 182 197Sensible cooling capacity (1) kW 27,2 34,5 38,3 46,4 55,7 69,5 75,5 93,5 92,1 102 117 132 145Compressor power input (1) kW 8,70 11,9 13,6 16,5 17,2 22,3 26,4 31,9 33,7 37,4 41,1 44,7 53HEATING ONLYHeating capacity (2) kW 31,9 42,9 49,6 57,5 64,9 87,3 94,7 113 115 130 140 172 186Compressors power input (2) kW 6,70 9,20 10,1 12,1 12,8 16,5 19,2 21,8 22,7 25,3 31,1 34,5 40,7OUTLET FANSSupply air flow rate m3/h 6500 7800 8600 10500 13000 15500 17500 21000 21000 23500 27000 29000 32000Useful static head (3) Pa 250 250 250 250 250 250 250 250 250 250 250 250 250Power Input kW 1,34 1,72 1,96 2,78 2,36 3,20 4,04 4,44 4,44 5,44 5,28 6,10 7,70SUCTION FANS/BLOWERSNominal air flow m3/h 6500 7800 8600 10500 13000 15500 17500 21000 21000 23500 27000 29000 32000Available static pressure (3) Pa 150 150 150 150 150 150 150 150 150 150 150 150 150Power Input kW 1,30 1,24 1,16 1,66 1,58 1,68 2,06 2,02 2,02 2,46 3 3,54 4,48COMPRESSORSNo. Compressors/No. Circuits N. 2 / 2 2 / 2 2 / 2 2 / 2 2 / 2 2 / 2 2 / 2 2 / 2 4 / 2 4 / 2 4 / 2 4 / 2 4 / 2NOISE LEVELSSound power (4) dB(A) 88 89 90 91 94 95 95 96 95 97 97 97 98SIZEA mm 4350 4350 4350 4350 4500 4500 4500 5295 5295 5295 6500 6500 6500B mm 1700 1700 1700 1700 2250 2250 2250 2250 2250 2250 2250 2250 2250H mm 1630 1630 1630 1630 2390 2390 2390 2390 2390 2390 2390 2390 2390Operating weight kg 1290 1320 1380 1400 2170 2230 2280 2750 2860 2880 3360 3450 3500

COOLINGHEATINGFREE COOLING

r HFCR-410A

SCROLLAXIALPLUG FANTHERMODYNAMIC

H

B

A

Page 294: Products Guide V01 - ParagonEfficient project management thanks to Climaveneta as unique project leader. Complete and specialized Organization Climaveneta qualifies itself for the

296

Main accessoriesHot gas post heating

CO2 control sensor for air quality

High efficiency filters: electronic or rigid pocket F7

Enthalpy free-cooling

Heating resource: hot water coil, electrical heater, burner methane gasSet-up for remote connectivity with ModBus/Echelon protocol cards

Remote keyboard (distance to 200m and to 500m)

FeaturesVARIABLE AIRFLOW FOR AIR TREATMENT SECTION

The specific VAir function is used to deliver air according to the flow of hot-cold air and many other operating parameters. This offers significant reductions in the power input of the fans.

HIGH ENERGY EFFICIENCY

The use of the R410A gas conjoined to the elevated thermodynamic recovery degree of the energy contained in the exhaust air guarantee a high efficiency during the operation.

PLUG-FAN VENTILATION

The plug-fan supply and return fan section matchs the high efficacy ventilation with a quicker and easier electric and aerolics installation of the unit.

SAFE USE

The wide working field and the accurate design of the unit ensure optimum capacities and guaranty comfort, with a continuous and constant bringing in of thermal load also in the more onerous thermohygrometric conditions.

VersionsB base version

CommandsAIR3000SEThe AIR3000SE controller offers advanced functions and algorithms. The keypad features functional controls and a complete LCD display that allows assessment and intervention on the unit by means of a multi-level menu with selectable user´s language. The presence of the programmable timer allows the creation of an operating profile containing up to 4 typical days and 10 time bands. The proportional step heat adjustment is based on the return temperature; proportional-integral adjustment can also be set. Functions include adjustment of available resources, ambient humidity, thermal or enthalpic (optional) free-cooling and delivery temperature limitation. The specific VAir function is used to deliver air according to the flow of hot-cold air and many other operating parameters. This offers significant reductions in the power input of the fans. The function can be selected from a parameter, it operates within settable flow values and is compatible with the adjusted rotation speed, adjusted flow and adjusted pressure ventilation methods. It also guarantees any differences required between return and delivery airflows. The diagnostics comprises a complete alarm management system, including black box (via PC) functions and an alarm log (via display or also PC) for optimised analysis of unit performance. Supervision can be easily developed via proprietary devices or the integration in third party systems by means of the most common protocols as ModBus, Bacnet, Bacnet-over-IP, Echelon LonWorks protocols. Compatibility with the remote keyboard managing up to 10 units.

Packaged

WHISPER-T 0102÷0604

High efficiency cooling only rooftop unit, for medium crowding applications

35,8 - 197 kWUnit DescriptionAutonomous rooftop unit, air/air cooling-only, for the thermohygrometric treatment, the filtration and the air change in wide areas. Both winter and summer operating conditions, double refrigerant circuit, scroll compressors with refrigerant R410A. Direct expansion finned external exchangers with thermodynamic effect on the exhaust air. Air treatment section with plug-fans and direct expansion finned internal exchangers. Management of air treatment section according to the requested heating or cooling capacity by the Vair function.

Page 295: Products Guide V01 - ParagonEfficient project management thanks to Climaveneta as unique project leader. Complete and specialized Organization Climaveneta qualifies itself for the

297

Minimum clearance required0102-0604

Switchboard side mm 1500Condensation coil side mm 2000

Note:

1 Cooling: Outdoor 35°C 50% R.H. / Indoor 27°C 47% R.H. / Mix 30%

2 ESP for standard configuration (optional accessories not included/calculated)

3 Sound power on the basis of measurements made in compliance with ISO 3744.

WHISPER-T / BModels 0102 0122 0152 0182 0202 0252 0302 0352 0364 0404 0454 0504 0604COOLING ONLYCooling capacity (1) kW 35,8 44,6 52,2 60,6 71,9 94,8 103 123 126 139 154 182 197Sensible cooling capacity (1) kW 27,6 33,7 38,3 45,7 55,7 69 77,3 92,1 92,8 101 116 131 144Compressor power input (1) kW 8,60 12,2 13,6 16,6 17,4 22,2 26,3 31,3 33,1 37,4 40,7 44,4 52,7OUTLET FANSSupply air flow rate m3/h 6500 7800 8600 10500 13000 15500 17500 21000 21000 23000 27000 29000 32000Available static pressure (2) Pa 250 250 250 250 250 250 250 250 250 250 250 250 250Power Input (3) kW 1,34 1,72 1,96 2,78 2,36 3,20 4,04 4,44 4,44 5,44 5,28 6,10 7,70SUCTION FANS/BLOWERSNominal air flow m3/h 6500 7800 8600 10500 13000 15500 17500 21000 21000 23500 27000 29000 32000Useful static head (2) Pa 150 150 150 150 150 150 150 150 150 150 150 150 150Power Input kW 1,30 1,24 1,16 1,66 1,58 1,68 2,06 2,02 2,02 2,46 3 3,54 4,48COMPRESSORSNo. Compressors/No. Circuits N. 2 / 2 2 / 2 2 / 2 2 / 2 2 / 2 2 / 2 2 / 2 2 / 2 4 / 2 4 / 2 4 / 2 4 / 2 4 / 2NOISE LEVELSSound power (3) dB(A) 88 89 90 91 94 95 95 96 95 97 97 97 98SIZEA mm 4350 4350 4350 4350 4500 4500 4500 5295 5295 5295 6500 6500 6500B mm 1700 1700 1700 1700 2250 2250 2250 2250 2250 2250 2250 2250 2250H mm 1630 1630 1630 1630 2390 2390 2390 2390 2390 2390 2390 2390 2390Operating weight kg 1290 1320 1380 1400 2170 2230 2280 2750 2860 2880 3360 3450 3500

COOLINGFREE COOLING

r HFCR-410A

SCROLLAXIALPLUG FANTHERMODYNAMIC

H

B

A

Page 296: Products Guide V01 - ParagonEfficient project management thanks to Climaveneta as unique project leader. Complete and specialized Organization Climaveneta qualifies itself for the

298

Main accessoriesCO2 control sensor for air quality

High efficiency filters: electronic or rigid pocket F7

Set-up for remote connectivity with ModBus/Echelon protocol cards

Remote keyboard (distance to 200m and to 500m)

FeaturesVARIABLE AIRFLOW FOR AIR TREATMENT SECTION

The specific VAir function is used to deliver air according to the flow of hot-cold air and many other operating parameters. This offers significant reductions in the power input of the fans.THERMOHYGROMETRIC MANAGEMENT ON THE SUPPLY AIRFLOWThe thermohygrometric management on the supply airflow is the best way to maintain the requested indoor temperature and relative humidity, even for high fresh airflow rate.

EXTREME ADAPTABILITY TO THE REQUESTED LOAD

The cooling/heating capacity provided is perfectly adapted to the load of the room to be served, thanks to the advantages of Inverter technology for compressors. This ensures excellent conditions of well-being.WIDE RANGE OF AIRFLOW MIX/PRECISION ON INDOOR CONDITIONSThis unit is perfect for air conditioning of a wide range of architectural construction types (fresh airflow up to 80%) in which indoor air conditions are the most important thing, moreover precise regulation on supply and indoor conditions is requested.

ROTARY-TYPE ENTHALPY RECOVERY

The exclusive rotary-type enthalpy recovery allows to get high running capacity guarantying a lower introduction of moisture in the summer operation of the unit.

VersionsB base version

CommandsAIR3000SEThe AIR3000SE controller offers advanced functions and algorithms. The keypad features functional controls and a complete LCD display that allows assessment and intervention on the unit by means of a multi-level menu with selectable user´s language. The presence of the programmable timer allows the creation of an operating profile containing up to 4 typical days and 10 time bands. The heat adjustment feature offers sophistcated capacity management wth proportional compressor modulation that can be based on the temperature of the delivery air. This allows accurate temperature adjustment and maximum comfort, partly thanks to the special integration with post-heating. Functions include adjustment of available resources, ambient humidity and enthalpic free-cooling. Defrosting is based on a self-adaptive propriety logic with monitoring of many operating and environmental parameters. The specific VAir function is used to deliver air according to the flow of hot-cold air and many other operating parameters. This offers significant reductions in the power input of the fans. The function can be selected from a parameter, it operates within settable flow values and is compatible with the adjusted rotation speed, adjusted flow and adjusted pressure ventilation methods. It also guarantees any differences required between return and delivery airflows. The diagnostics comprises a complete alarm management system, including black box (via PC) functions and an alarm log (via display or also PC) for optimised analysis of unit performance. Supervision can be easily developed via proprietary devices or the integration in third party systems by means of the most common protocols as ModBus, Bacnet, Bacnet-over-IP, Echelon LonWorks protocols. Compatibility with the remote keyboard managing up to 10 units.

Packaged

i-WHISPER ENTHALPY 0182÷0753

High efficiency reversible rooftop unit, with enthalpy recovery for medium crowding applications

87,0 - 338 kWUnit DescriptionAutonomous rooftop unit, air/air reversible, for the thermohygrometric treatment, the filtration and the air change in wide areas. Both winter and summer operating conditions, double refrigerant circuit, scroll compressors with variable speed and refrigerant R410A. Direct expansion finned external exchangers with thermodynamic effect on the exhaust air, axial fans and condensation control device. Enthalpic Freecooling. Post-heating gas coil. Air treatment section with plug-fans and direct expansion finned internal exchangers. Enthalpic rotary heat recovery. Management of air treatment section according to the requested heating or cooling capacity by the Vair function.

Page 297: Products Guide V01 - ParagonEfficient project management thanks to Climaveneta as unique project leader. Complete and specialized Organization Climaveneta qualifies itself for the

299

Minimum clearance required0182-0753

Switchboard side mm 1500Condensation coil side mm 2000

Note:

1 Cooling: Outdoor 35°C 50% R.H. / Indoor 26°C 50% R.H. / Mix 80%

2 Heating: Outdoor 7°C 87% R.H. / Indoor 20°C 50% R.H. / Mix 80%

3 ESP for standard configuration (optional accessories not included/calculated)

4 Sound power on the basis of measurements made in compliance with ISO 3744.

i-WHISPER ENTHALPY / BModels 0182 0202 0262 0302 0352 0402 0553 0653 0753COOLING ONLYCooling capacity + Recovery (1) kW 87 113 134 150 166 200 242 294 338Compressor power input (1) kW 19 20 26 27 34 40 55 63 73HEATING ONLYHeating capacity + Recovery (2) kW 86 104 124 136 159 190 248 293 335Compressors power input (2) kW 16 18 21 23 28 34 45 54 61OUTLET FANSSupply air flow rate m3/h 7200 9000 11000 12500 13500 16500 20000 24000 30000Useful static head (3) Pa 810 780 705 785 765 790 805 830 840Power Input kW 3,50 3,60 5,30 6 6,30 8,50 10,8 12,6 16,1SUCTION FANS/BLOWERSNominal air flow m3/h 7200 9000 11000 12500 13500 16500 20000 24000 30000Available static pressure (3) Pa 600 600 530 600 600 600 600 600 600Power Input kW 2,70 3 3,50 4,60 5 7,50 7,10 9,50 12,3COMPRESSORSNo. Compressors/No. Circuits N. 2/2 2/2 2/2 2/2 2/2 2/2 3/2 3/2 3/2NOISE LEVELSSound power (4) dB(A) 92 94 94 94 95 96 97 97 98SIZEA mm 4350 4500 4500 4500 4500 5300 6500 6500 6500B mm 1700 2250 2250 2250 2250 2250 2250 2250 2250H mm 1630 2390 2390 2390 2390 2390 2390 2390 2390Operating weight kg * * * * * * * * *

COOLINGHEATINGFREE COOLING

r HFCR-410A

SCROLLPLUG FANROTARYTHERMODYNAMIC

H

B

A

Page 298: Products Guide V01 - ParagonEfficient project management thanks to Climaveneta as unique project leader. Complete and specialized Organization Climaveneta qualifies itself for the

300

Main accessoriesHot gas post heating

CO2 control sensor for air quality

High efficiency filters: electronic or rigid pocket F7

Enthalpy free-cooling

Set-up for remote connectivity with ModBus/Echelon protocol cards

Remote keyboard (distance to 200m and to 500m)

FeaturesVARIABLE AIRFLOW FOR AIR TREATMENT SECTION

The specific VAir function is used to deliver air according to the flow of hot-cold air and many other operating parameters. This offers significant reductions in the power input of the fans.

HIGH ENERGY EFFICIENCY

The use of the R410A gas conjoined to the elevated thermodynamic recovery degree of the energy contained in the exhaust air guarantee a high efficiency during the operation.

ROTARY-TYPE ENTHALPY RECOVERY

The exclusive rotary recovery allows sensible and latent energy from the exhaust airflow both in winter and summer conditions. The latent recovery, in particular, is important in dehumidification in summer and humidification in winter for indoor, with very high efficiency values.

PLUG-FAN VENTILATION

The plug-fan supply and return fan section matchs the high efficacy ventilation with a quicker and easier electric and aerolics installation of the unit.

SAFE USE

The wide working field and the accurate design of the unit ensure optimum capacities and guaranty comfort, with a continuous and constant bringing in of thermal load also in the more onerous thermohygrometric conditions.

VersionsB base version

CommandsAIR3000SEThe AIR3000SE controller offers advanced functions and algorithms. The keypad features functional controls and a complete LCD display that allows assessment and intervention on the unit by means of a multi-level menu with selectable user´s language. The presence of the programmable timer allows the creation of an operating profile containing up to 4 typical days and 10 time bands. The proportional step heat adjustment is based on the return temperature; proportional-integral adjustment can also be set. Functions include adjustment of available resources, ambient humidity, thermal or enthalpic (optional) free-cooling and delivery temperature limitation. Defrosting is based on a self-adaptive propriety logic with monitoring of many operating and environmental parameters. The specific VAir function is used to deliver air according to the flow of hot-cold air and many other operating parameters. This offers significant reductions in the power input of the fans. The function can be selected from a parameter, it operates within settable flow values and is compatible with the adjusted rotation speed, adjusted flow and adjusted pressure ventilation methods. It also guarantees any differences required between return and delivery airflows. The diagnostics comprises a complete alarm management system, including black box (via PC) functions and an alarm log (via display or also PC) for optimised analysis of unit performance. Supervision can be easily developed via proprietary devices or the integration in third party systems by means of the most common protocols as ModBus, Bacnet, Bacnet-over-IP, Echelon LonWorks protocols. Compatibility with the remote keyboard managing up to 10 units.

Packaged

WHISPER ENTHALPY 0102÷0604

High efficiency reversible rooftop unit, with enthalpy recovery for medium crowding applications

47,4 - 243 kWUnit DescriptionAutonomous rooftop unit, air/air reversible, for the thermohygrometric treatment, the filtration and the air change in wide areas. Both winter and summer operating conditions, double refrigerant circuit, scroll compressors with refrigerant R410A. Direct expansion finned external exchangers with thermodynamic effect on the exhaust air. Air treatment section with plug-fans and direct expansion finned internal exchangers. Enthalpic rotary heat recovery. Management of air treatment section according to the requested heating or cooling capacity by the Vair function.

Page 299: Products Guide V01 - ParagonEfficient project management thanks to Climaveneta as unique project leader. Complete and specialized Organization Climaveneta qualifies itself for the

301

Minimum clearance required0102-0604

Switchboard side mm 1500Condensation coil side mm 2000

Note:

1 Cooling: Outdoor 35°C 50% R.H. / Indoor 27°C 47% R.H. / Mix 30%

2 Heating: Outdoor 7°C 87% R.H. / Indoor 20°C 50% R.H. / Mix 30%

3 ESP for standard configuration (optional accessories not included/calculated)

4 Sound power on the basis of measurements made in compliance with ISO 3744.

WHISPER ENTHALPY / BModels 0102 0122 0152 0182 0202 0252 0302 0352 0364 0404 0454 0504 0604COOLING ONLYCooling capacity + Recovery (1) kW 47,4 58,3 66,6 77,5 96,7 122 133 157 160 176 195 225 243Sensible cooling capacity + Recovery (1)

kW 31,3 38 43,6 52,2 64,2 79,1 87,6 105 107 118 133 149 163

Compressor power input (1) kW 8,60 11,7 13,4 16,2 16,9 21,9 26 31,4 33 36,9 40,5 44 52,2HEATING ONLYHeating capacity + Recovery (2) kW 40,8 53,3 60,7 70,7 83,2 108 118 140 143 159 173 207 224Compressors power input (2) kW 7,20 9,90 10,8 12,8 13,7 17,6 20,6 23,2 24,2 26,9 33,2 36,8 43,2OUTLET FANSSupply air flow rate m3/h 6500 7800 8600 10500 13000 15500 17500 21000 21000 23500 27000 29000 32000Useful static head (3) Pa 250 250 250 250 250 250 250 250 250 250 250 250 250Power Input kW 1,50 1,96 2,24 3,18 2,74 3,68 4,66 5,22 5,22 6,38 7,84 9,06 11,3SUCTION FANS/BLOWERSNominal air flow m3/h 6500 7800 8600 10500 13000 15500 17500 21000 21000 23500 27000 29000 32000Available static pressure (3) Pa 150 150 150 150 150 150 150 150 150 150 150 150 150Power Input kW 1,04 1,62 1,92 2,82 2 2,68 3,98 3,66 3,66 4,50 4,42 5,16 6,82COMPRESSORSNo. Compressors/No. Circuits N. 2 / 2 2 / 2 2 / 2 2 / 2 2 / 2 2 / 2 2 / 2 2 / 2 4 / 2 4 / 2 4 / 2 4 / 2 4 / 2NOISE LEVELSSound power (4) dB(A) 88 89 90 91 94 95 95 96 95 97 97 97 98SIZEA mm 4350 4350 4350 4350 4500 4500 4500 5295 5295 5295 6500 6500 6500B mm 1700 1700 1700 1700 2250 2250 2250 2250 2250 2250 2250 2250 2250H mm 1630 1630 1630 1630 2390 2390 2390 2390 2390 2390 2390 2390 2390Operating weight kg 1430 1460 1520 1540 2430 2480 2540 3000 3110 3130 3620 3710 3760

COOLINGHEATINGFREE COOLING

r HFCR-410A

SCROLLAXIALPLUG FANROTARYTHERMODYNAMIC

H

B

A

Page 300: Products Guide V01 - ParagonEfficient project management thanks to Climaveneta as unique project leader. Complete and specialized Organization Climaveneta qualifies itself for the

302

Main accessoriesHot gas post heating

CO2 control sensor for air quality

High efficiency filters: electronic or rigid pocket F7

Enthalpy free-cooling

Heating resource: hot water coil, electrical heater, burner methane gasSet-up for remote connectivity with ModBus/Echelon protocol cards

Remote keyboard (distance to 200m and to 500m)

FeaturesVARIABLE AIRFLOW FOR AIR TREATMENT SECTION

The specific VAir function is used to deliver air according to the flow of hot-cold air and many other operating parameters. This offers significant reductions in the power input of the fans.

HIGH ENERGY EFFICIENCY

The use of the R410A gas conjoined to the elevated thermodynamic recovery degree of the energy contained in the exhaust air guarantee a high efficiency during the operation.

ROTARY-TYPE ENTHALPY RECOVERY

The exclusive rotary recovery allows sensible and latent energy from the exhaust airflow both in winter and summer conditions. The latent recovery, in particular, is important in dehumidification in summer and humidification in winter for indoor, with very high efficiency values.

PLUG-FAN VENTILATION

The plug-fan supply and return fan section matchs the high efficacy ventilation with a quicker and easier electric and aerolics installation of the unit.

SAFE USE

The wide working field and the accurate design of the unit ensure optimum capacities and guaranty comfort, with a continuous and constant bringing in of thermal load also in the more onerous thermohygrometric conditions.

VersionsB base version

CommandsAIR3000SEThe AIR3000SE controller offers advanced functions and algorithms. The keypad features functional controls and a complete LCD display that allows assessment and intervention on the unit by means of a multi-level menu with selectable user´s language. The presence of the programmable timer allows the creation of an operating profile containing up to 4 typical days and 10 time bands. The proportional step heat adjustment is based on the return temperature; proportional-integral adjustment can also be set. Functions include adjustment of available resources, ambient humidity, thermal or enthalpic (optional) free-cooling and delivery temperature limitation. The specific VAir function is used to deliver air according to the flow of hot-cold air and many other operating parameters. This offers significant reductions in the power input of the fans. The function can be selected from a parameter, it operates within settable flow values and is compatible with the adjusted rotation speed, adjusted flow and adjusted pressure ventilation methods. It also guarantees any differences required between return and delivery airflows. The diagnostics comprises a complete alarm management system, including black box (via PC) functions and an alarm log (via display or also PC) for optimised analysis of unit performance. Supervision can be easily developed via proprietary devices or the integration in third party systems by means of the most common protocols as ModBus, Bacnet, Bacnet-over-IP, Echelon LonWorks protocols. Compatibility with the remote keyboard managing up to 10 units.

Packaged

WHISPER ENTHALPY-T 0102÷0604

High efficiency cooling only rooftop unit, with enthalpy recovery for medium crowding applications

47,4 - 243 kWUnit DescriptionAutonomous rooftop unit, air/air cooling-only, for the thermohygrometric treatment, the filtration and the air change in wide areas. Both winter and summer operating conditions, double refrigerant circuit, scroll compressors with refrigerant R410A. Direct expansion finned external exchangers with thermodynamic effect on the exhaust air. Air treatment section with plug-fans and direct expansion finned internal exchangers. Enthalpic rotary heat recovery. Management of air treatment section according to the requested heating or cooling capacity by the Vair function.

Page 301: Products Guide V01 - ParagonEfficient project management thanks to Climaveneta as unique project leader. Complete and specialized Organization Climaveneta qualifies itself for the

303

Minimum clearance required0102-0604

Switchboard side mm 1500Condensation coil side mm 2000

Note:

1 Cooling: Outdoor 35°C 50% R.H. / Indoor 27°C 47% R.H. / Mix 30%

2 ESP for standard configuration (optional accessories not included/calculated)

3 Sound power on the basis of measurements made in compliance with ISO 3744.

WHISPER ENTHALPY-T / BModels 0102 0122 0152 0182 0202 0252 0302 0352 0364 0404 0454 0504 0604COOLING ONLYCooling capacity + Recovery (1) kW 47,4 58,4 66,5 77,5 96,9 122 133 158 161 176 196 225 243Sensible cooling capacity + Recovery (1)

kW 31,3 38 43,6 52,2 64,2 79,1 87 104 107 118 133 149 163

Compressor power input (1) kW 8,50 11,7 13,3 16,3 16,8 21,8 25,9 30,9 32,5 36,8 40,1 43,8 52OUTLET FANSSupply air flow rate m3/h 6500 7800 8600 10500 13000 15500 17500 21000 21000 23500 27000 29000 32000Useful static head (2) Pa 250 250 250 250 250 250 250 250 250 250 250 250 250Power Input kW 1,50 1,96 2,24 3,18 2,74 3,68 4,66 5,22 5,22 6,38 7,84 9,06 11,3SUCTION FANS/BLOWERSNominal air flow m3/h 6500 7800 8600 10500 13000 15500 17500 21000 21000 23500 27000 29000 32000Available static pressure (2) Pa 150 150 150 150 150 150 150 150 150 150 150 150 150Power Input kW 1,04 1,62 1,92 2,82 2 2,68 3,98 3,66 3,66 4,50 4,42 5,16 6,82COMPRESSORSNo. Compressors/No. Circuits N. 2 / 2 2 / 2 2 / 2 2 / 2 2 / 2 2 / 2 2 / 2 2 / 2 4 / 2 4 / 2 4 / 2 4 / 2 4 / 2NOISE LEVELSSound power (3) dB(A) 88 89 90 91 94 95 95 96 95 97 97 97 98SIZEA mm 4350 4350 4350 4350 4500 4500 4500 5295 5295 5295 6500 6500 6500B mm 1700 1700 1700 1700 2250 2250 2250 2250 2250 2250 2250 2250 2250H mm 1630 1630 1630 1630 2390 2390 2390 2390 2390 2390 2390 2390 2390Operating weight kg 1430 1460 1520 1540 2430 2480 2540 3000 3110 3130 3620 3710 3760

COOLINGFREE COOLING

r HFCR-410A

SCROLLAXIALPLUG FANROTARYTHERMODYNAMIC

H

B

A

Page 302: Products Guide V01 - ParagonEfficient project management thanks to Climaveneta as unique project leader. Complete and specialized Organization Climaveneta qualifies itself for the

304

Main accessoriesHot gas post heating

High efficiency filters: electronic or rigid pocket F7

Enthalpy free-cooling

Set-up for remote connectivity with Echelon protocol cards

Remote keyboard (distance to 200m and to 500m)

FeaturesVARIABLE AIRFLOW FOR AIR TREATMENT SECTION

The specific VAir function is used to deliver air according to the flow of hot-cold air and many other operating parameters. This offers significant reductions in the power input of the fans.

HIGH ENERGY EFFICIENCY

The use of the R410A gas conjoined to the elevated thermodynamic recovery degree of the energy contained in the exhaust air guarantee a high efficiency during the operation.

ROTARY-TYPE ENTHALPY RECOVERY

The exclusive rotary recovery allows sensible and latent energy from the exhaust airflow both in winter and summer conditions. The latent recovery, in particular, is important in dehumidification in summer and humidification in winter for indoor, with very high efficiency values.

PLUG-FAN VENTILATION

The plug-fan supply and return fan section matchs the high efficacy ventilation with a quicker and easier electric and aerolics installation of the unit.

COMFORT

The wide working field, the air quality probe, the predisposition for the remote supervising and the accurate planning of the unit ensure optimum capacities and comfort warrantee, with a continuous and constant bringing in of thermal load also in the more onerous thermohygrometric and crowding conditions.

VersionsB base version

CommandsAIR3000SEThe AIR3000SE controller offers advanced functions and algorithms. The keypad features functional controls and a complete LCD display that allows assessment and intervention on the unit by means of a multi-level menu with selectable user´s language. The presence of the programmable timer allows the creation of an operating profile containing up to 4 typical days and 10 time bands. The proportional step heat adjustment is based on the return temperature; proportional-integral adjustment can also be set. Functions include adjustment of available resources, ambient humidity, thermal or enthalpic (optional) free-cooling and delivery temperature limitation. Defrosting is based on a self-adaptive propriety logic with monitoring of many operating and environmental parameters. The specific VAir function is used to deliver air according to the flow of hot-cold air and many other operating parameters. This offers significant reductions in the power input of the fans. The function can be selected from a parameter, it operates within settable flow values and is compatible with the adjusted rotation speed, adjusted flow and adjusted pressure ventilation methods. It also guarantees any differences required between return and delivery airflows. The diagnostics comprises a complete alarm management system, including black box (via PC) functions and an alarm log (via display or also PC) for optimised analysis of unit performance. Supervision can be easily developed via proprietary devices or the integration in third party systems by means of the most common protocols as ModBus, Bacnet, Bacnet-over-IP, Echelon LonWorks protocols. Compatibility with the remote keyboard managing up to 10 units.

Packaged

WHISPER HALL 110÷400

High efficiency reversible rooftop unit, with enthalpy recovery for high crowding applications

45,9 - 146 kWUnit DescriptionAutonomous rooftop unit, air/air reversible, for the thermohygrometric treatment, the filtration and the air change in wide areas. Both winter and summer operating conditions, double refrigerant circuit, scroll compressors with refrigerant R410A. Direct expansion finned external exchangers with thermodynamic effect on the exhaust air. Air treatment section with plug-fans and direct expansion finned internal exchangers. Air quality control with CO2 probe. Enthalpic rotary heat recovery. Management of air treatment section according to the requested heating or cooling capacity by the Vair function.

Page 303: Products Guide V01 - ParagonEfficient project management thanks to Climaveneta as unique project leader. Complete and specialized Organization Climaveneta qualifies itself for the

305

Minimum clearance required110-400

Switchboard side mm 1500Condensation coil side mm 2000

Note:

1 Cooling: Outdoor 32°C 50% R.H. / Indoor 26°C 50% R.H. / Mix 75%

2 Heating: Outdoor -5°C 85% R.H. / Indoor 20°C 50% R.H. / Mix 75%

3 ESP for standard configuration (optional accessories not included/calculated)

4 Sound power on the basis of measurements made in compliance with ISO 3744.

WHISPER HALL / BModels 110 140 180 200 260 300 360 400COOLING ONLYCooling capacity + Recovery (1) kW 45,9 55,7 63,7 72 98,3 115 128 146Sensible cooling capacity + Recovery (1)

kW 25,1 31,1 36,8 41,6 55,7 65,1 73,7 83,2

Compressor power input (1) kW 7,60 10,9 12,4 15 14,9 20,4 24,1 29HEATING ONLYHeating capacity + Recovery (2) kW 53,1 65,4 75,5 84,4 115 137 154 171Compressors power input (2) kW 7,10 8,80 9,70 11,7 12,4 16,8 19,4 21,5OUTLET FANSSupply air flow rate m3/h 4300 5400 6800 7800 10000 11700 14000 15000Useful static head (3) Pa 260 260 260 260 260 260 260 260Power Input kW 1,28 1,72 2,42 3,08 3,08 4,02 5,64 6,42SUCTION FANS/BLOWERSNominal air flow m3/h 4300 5400 6800 7800 10000 11700 14000 15000Available static pressure (3) Pa 150 150 150 150 150 150 150 150Power Input kW 1,22 1,30 1,48 1,72 1,58 1,96 3,04 2,96COMPRESSORSNo. Compressors/No. Circuits N. 2 / 2 2 / 2 2 / 2 2 / 2 2 / 2 2 / 2 2 / 2 2 / 2NOISE LEVELSSound power (4) dB(A) 88 89 90 91 94 94 94 95SIZEA mm 4350 4350 4350 4350 4500 4500 4500 5295B mm 1700 1700 1700 1700 2250 2250 2250 2250H mm 1630 1630 1630 1630 2390 2390 2390 2390Operating weight kg 1430 1460 1520 1540 2430 2480 2540 3000

COOLINGHEATINGFREE COOLING

r HFCR-410A

SCROLLAXIALPLUG FANROTARYTHERMODYNAMIC

Page 304: Products Guide V01 - ParagonEfficient project management thanks to Climaveneta as unique project leader. Complete and specialized Organization Climaveneta qualifies itself for the

306

Main accessoriesSet-up for remote connectivity with ModBus/Echelon protocol cards

Hot gas post heating

CO2 control sensor for air quality

High efficiency filters: electronic or rigid pocket F7

Enthalpy free-cooling

Remote keyboard (distance to 200m and to 500m)

FeaturesREFRIGERANT GAS R410A

The use of R410A has resulted in units offering better energy efficiency in full respect for the environment (ODP = 0).

COMFORT

The wide working field and the accurate designed of the unit ensure optimum capacities and guaranty comfort, with a continuous and constant bringing in of thermal load also in the more onerous thermohygrometric conditions.

SAFE USE

The refrigerant piping and the regulation devices are put in suitable space, splitted from the air treatment section. This means a lower accidental risk to contaminate the indoor environment and moreover allowing the thermostatic valve adjustment while the unit is on.

FLEXIBILITY

Climaveneta offers units with innumerable choices for the supply and return airflows directions.

VersionsB base version

CommandsAIR3000The controller AIR3000 offers advanced functions and algorithms. The keypad is generously sized with full operating status display. The controls and detailed LCD make access to unit settings easy and safe. Temperature regulation is based on step-wise proportional logic referring to the return air temperature. The diagnostics includes full management of alarms with the black-box and alarm logging functions for enhanced analysis of the unit operation. Supervision can be easily developed via proprietary devices or the integration in third party systems by means of the most common protocols as ModBus, Echelon LonWorks. Compatibility with the remote keyboard managing up to 10 units. Availability of an internal real time clock for operation scheduling (4-day profiles with 10 hour belts). The defrost adopts a proprietary self-adaptive logic, which features the monitoring of numerous operational parameters. This allows to reduce the number and duration of the defrost cycles, with a benefit for the overall energy efficiency.

Packaged

WISDOM 0101÷1204

Reversible rooftop unit, for medium crowding applications

34,5 - 355 kWUnit DescriptionUnit for outdoor installation, reversible and direct expansion for the air conditioning, with scroll compressors running on R410A, sandwich panel with thickness of 42mm, aluminium frame, base made in pre-painted galvanized steel profiles and centrifugal fan section. The unit in standard execution can treat recirculating-only air; other available executions (optionals) are MIX (return air and fresh air mix), FCS (Standard Free-Cooling with supply fans) or FCC (Centrifugal Free-Cooling with supply and return fans).

Page 305: Products Guide V01 - ParagonEfficient project management thanks to Climaveneta as unique project leader. Complete and specialized Organization Climaveneta qualifies itself for the

307

Minimum clearance required0101-1204

Switchboard side mm 1500Switchboard opposite side mm 0Condensation coil side mm 2000

Note:

1 Cooling: Outdoor 34°C 50% R.H. Indoor 27°C 47% R.H.

2 Heating: Outdoor 7°C 87% R.H. / Indoor 20°C 50% R.H.

3 ESP for standard configuration (optional accessories not included/calculated)

4 Sound power on the basis of measurements made in compliance with ISO 3744.

5 Sound pressure in open field conditions on reflecting surface. Condensing coil side average value at 1 metre from the surface and at 1 m height in relation to the unit supporting base.

6 Unit in standard configuration/execution, without optional accessories

Models 0364 0404 0454 0504 0604 0704 0804 0904 1004 1104 1204COOLING ONLYCooling capacity (1) kW 113 128 153 168 189 213 258 278 316 335 355Sensible cooling capacity (1) kW 86 96,8 116 125 142 159 196 211 238 245 253Compressor power input (1) kW 27,9 35,4 39,9 44,8 52,5 61,2 68,5 78,4 84,8 93 105HEATING ONLYHeating capacity (2) kW 110 126 148 170 185 213 256 279 313 343 378Compressors power input (2) kW 23 28,6 32,3 38,3 41,7 52,3 57,6 65,4 70,2 78,8 91,4OUTLET FANSSupply air flow rate m3/h 21000 23500 27000 29000 32000 45000 50000 54000 56000 56000 56000Available static pressure (3) Pa 271 303 215 261 333 235 255 400 290 290 290Power Input kW 6 8 6 8 11 12 16 22 30 30 30COMPRESSORSNo. Compressors/No. Circuits N. 4/2 4/2 4/2 4/2 4/2 4/2 4/2 4/2 4/2 4/2 4/2NOISE LEVELSSound power (4) dB(A) 87 87 93 93 93 * * * * * *Sound pressure (5) dB(A) 71 71 76 76 76 * * * * * *SIZEA (6) mm 3900 3900 3900 3900 3900 6580 6580 6580 6580 6580 6580B (6) mm 2330 2330 2330 2330 2330 2330 2330 2330 2330 2330 2330H (6) mm 1820 1820 2380 2380 2380 2350 2350 2350 2350 2350 2350Operating weight (6) kg 1560 1650 1890 2080 2230 3530 3790 3790 3910 4150 4160

WISDOM / BModels 0101 0121 0151 0102 0122 0152 0182 0202 0252 0302 0352COOLING ONLYCooling capacity (1) kW 34,5 41,2 48,5 33,8 41,4 49,3 55 65,9 85,7 92,9 109Sensible cooling capacity (1) kW 26,8 30,9 36,6 26,5 31 37,9 42,5 50,6 65,6 71,1 80,9Compressor power input (1) kW 8,30 11,6 12,6 8,30 12,6 13 14,6 17,4 23 26,8 29,1HEATING ONLYHeating capacity (2) kW 33,2 43,2 47,6 32,2 44,1 48,7 53,1 63,4 83,8 90,9 109Compressors power input (2) kW 7 9,90 10,5 6,80 10,6 10,7 11,4 14,1 18,3 21 24OUTLET FANSSupply air flow rate m3/h 6500 7800 8500 6500 7800 8600 10500 13000 15500 17500 21000Available static pressure (3) Pa 220 219 330 220 219 315 261 208 202 269 271Power Input kW 1,10 1,50 2,20 1,10 1,50 2,20 3 2,20 3 4,40 6COMPRESSORSNo. Compressors/No. Circuits N. 1/1 1/1 1/1 2/2 2/2 2/2 2/2 2/2 2/2 2/2 2/2NOISE LEVELSSound power (4) dB(A) 78 78 78 78 78 78 78 84 84 84 87Sound pressure (5) dB(A) 63 63 63 63 63 63 63 68 68 68 71SIZEA (6) mm 2900 2900 2900 2900 2900 2900 2900 3400 3400 3400 3400B (6) mm 1780 1780 1780 1780 1780 1780 1780 2330 2330 2330 2330H (6) mm 1640 1640 1640 1640 1640 1640 1640 1790 1790 1790 1790Operating weight (6) kg 870 910 950 870 910 980 1010 1210 1290 1350 1450

COOLINGHEATINGFREE COOLING

r HFCR-410A

SCROLLAXIALCENTRIFUGAL

H

B

A

Page 306: Products Guide V01 - ParagonEfficient project management thanks to Climaveneta as unique project leader. Complete and specialized Organization Climaveneta qualifies itself for the

308

Main accessoriesHot gas post heating

CO2 control sensor for air quality

High efficiency filters: electronic or rigid pocket F7

Enthalpy free-cooling

Heating resource: hot water coil, electrical heater, burner methane gasSet-up for remote connectivity with ModBus/Echelon protocol cards

Remote keyboard (distance to 200m and to 500m)

FeaturesREFRIGERANT GAS R410A

The use of R410A has resulted in units offering better energy efficiency in full respect for the environment (ODP = 0).

COMFORT

The wide working field and the accurate designed of the unit ensure optimum capacities and guaranty comfort, with a continuous and constant bringing in of thermal load also in the more onerous thermohygrometric conditions.

SAFE USE

The refrigerant piping and the regulation devices are put in suitable space, splitted from the air treatment section. This means a lower accidental risk to contaminate the indoor environment and moreover allowing the thermostatic valve adjustment while the unit is on.

FLEXIBILITY

Climaveneta offers units with innumerable choices for the supply and return airflows directions.

VersionsB base version

CommandsAIR3000The controller AIR3000 offers advanced functions and algorithms. The keypad is generously sized with full operating status display. The controls and detailed LCD make access to unit settings easy and safe. Temperature regulation is based on step-wise proportional logic referring to the return air temperature. The diagnostics includes full management of alarms with the black-box and alarm logging functions for enhanced analysis of the unit operation. Supervision can be easily developed via proprietary devices or the integration in third party systems by means of the most common protocols as ModBus, Echelon LonWorks. Compatibility with the remote keyboard managing up to 10 units. Availability of an internal real time clock for operation scheduling (4-day profiles with 10 hour belts).

Packaged

WISDOM-T 0101÷1204

Cooling only rooftop unit, for medium crowding applications

34,7 - 357 kWUnit DescriptionUnit for outdoor installation, cooling-only and direct expansion for the air conditioning, with scroll compressors running on R410A, sandwich panel with thickness of 42mm, aluminium frame, base made in pre-painted galvanized steel profiles and centrifugal fan section. The unit in standard execution can treat recirculating-only air; other available executions (optionals) are MIX (return air and fresh air mix), FCS (Standard Free-Cooling with supply fans) or FCC (Centrifugal Free-Cooling with supply and return fans).

Page 307: Products Guide V01 - ParagonEfficient project management thanks to Climaveneta as unique project leader. Complete and specialized Organization Climaveneta qualifies itself for the

309

Minimum clearance required0101 0121-1204

Switchboard side mm 1500 2000Condensation coil side mm 2000 2000

Note:

1 Cooling: Outdoor 34°C 50% R.H. Indoor 27°C 47% R.H.

2 ESP for standard configuration (optional accessories not included/calculated)

3 Sound power on the basis of measurements made in compliance with ISO 3744.

4 Sound pressure in open field conditions on reflecting surface. Condensing coil side average value at 1 metre from the surface and at 1 m height in relation to the unit supporting base.

5 Unit in standard configuration/execution, without optional accessories

Models 0364 0404 0454 0504 0604 0704 0804 0904 1004 1104 1204COOLING ONLYCooling capacity (1) kW 110 129 154 170 191 215 260 280 318 337 357Sensible cooling capacity (1) kW 85,3 97,1 116 126 142 159 197 211 239 246 253Compressor power input (1) kW 29,7 34,7 39,2 44,1 51,5 60,1 67,5 77,0 83,6 91,9 104OUTLET FANSSupply air flow rate m3/h 21000 23500 27000 29000 32000 45000 50000 54000 56000 56000 56000Available static pressure (2) Pa 271 303 215 261 333 235 255 400 290 290 290Power Input kW 6,00 8,00 6,00 8,00 11,0 12,0 16,0 22,0 30,0 30,0 30,0COMPRESSORSNo. Compressors/No. Circuits N. 4/2 4/2 4/2 4/2 4/2 4/2 4/2 4/2 4/2 4/2 4/2NOISE LEVELSSound power (3) dB(A) 87,0 87,0 93,0 93,0 93,0 * * * * * * Sound pressure (4) dB(A) 71,0 71,0 76,0 76,0 76,0 * * * * * * SIZEA (5) mm 3900 3900 3900 3900 3900 6580 6580 6580 6580 6580 6580B (5) mm 2330 2330 2330 2330 2330 2330 2330 2330 2330 2330 2330H (5) mm 1820 1820 2380 2380 2380 2350 2350 2350 2350 2350 2350Operating weight (5) kg 1560 1650 1890 2080 2230 3530 3790 3790 3910 4150 4160

WISDOM-T / BModels 0101 0121 0151 0102 0122 0152 0182 0202 0252 0302 0352COOLING ONLYCooling capacity (1) kW 34,7 - 48,8 34,1 41,8 47,8 55,3 66,4 83,2 93,8 109 Sensible cooling capacity (1) kW 26,9 - 36,7 26,7 31,1 37,4 42,6 50,9 64,8 71,3 80,9 Compressor power input (1) kW 8,11 - 12,4 8,11 12,3 13,8 14,3 17,1 24,4 26,2 29,1 OUTLET FANSSupply air flow rate m3/h 6500 - 8500 6500 7800 8600 10500 13000 15500 17500 21000 Available static pressure (2) Pa 220 - 330 220 219 315 261 208 202 269 271 Power Input kW 1,10 - 2,20 1,10 1,50 2,20 3,00 2,20 3,00 4,40 6,00 COMPRESSORSNo. Compressors/No. Circuits N. 1/1 - 1/1 2/2 2/2 2/2 2/2 2/2 2/2 2/2 2/2 NOISE LEVELSSound power (3) dB(A) 78,0 - 78,0 78,0 78,0 78,0 78,0 84,0 84,0 84,0 87,0 Sound pressure (4) dB(A) 63,0 - 63,0 63,0 63,0 63,0 63,0 68,0 68,0 68,0 71,0 SIZEA (5) mm 2900 - 2900 2900 2900 2900 2900 3400 3400 3400 3400 B (5) mm 1780 - 1780 1780 1780 1780 1780 2330 2330 2330 2330 H (5) mm 1640 - 1640 1640 1640 1640 1640 1790 1790 1790 1790 Operating weight (5) kg 870 - 950 870 910 980 1010 1210 1290 1350 1450

COOLINGFREE COOLING

r HFCR-410A

SCROLLAXIALCENTRIFUGAL

H

B

A

Page 308: Products Guide V01 - ParagonEfficient project management thanks to Climaveneta as unique project leader. Complete and specialized Organization Climaveneta qualifies itself for the

310

Main accessoriesHot gas post heating

CO2 control sensor for air quality

High efficiency filters: electronic or rigid pocket F7

Enthalpy free-cooling

Set-up for remote connectivity with ModBus/Echelon protocol cards

Remote keyboard (distance to 200m and to 500m)

FeaturesREFRIGERANT GAS R410A

The use of R410A has resulted in units offering better energy efficiency in full respect for the environment (ODP = 0).

STATIC RECOVERY WITH CROSS FLOWS

The air/air cross flow exchangery allows a constant and efficient exhaust airflow energy recovery. The excellent efficiency values (more than 50%) in winter conditions and no power consumption (there are no moving parts) give a concrete energy and economic saving.

COMFORT

The wide working field and the accurate designed of the unit ensure optimum capacities and guaranty comfort, with a continuous and constant bringing in of thermal load also in the more onerous thermohygrometric conditions.

SAFE USE

The refrigerant piping and the regulation devices are put in suitable space, splitted from the air treatment section. This means a lower accidental risk to contaminate the indoor environment and moreover allowing the thermostatic valve adjustment while the unit is on.

FLEXIBILITY

Climaveneta offers units with innumerable choices for the supply and return airflows directions.

VersionsB base version

CommandsAIR3000The controller AIR3000 offers advanced functions and algorithms. The keypad is generously sized with full operating status display. The controls and detailed LCD make access to unit settings easy and safe. Temperature regulation is based on step-wise proportional logic referring to the return air temperature. The diagnostics includes full management of alarms with the black-box and alarm logging functions for enhanced analysis of the unit operation. Supervision can be easily developed via proprietary devices or the integration in third party systems by means of the most common protocols as ModBus, Echelon LonWorks. Compatibility with the remote keyboard managing up to 10 units. Availability of an internal real time clock for operation scheduling (4-day profiles with 10 hour belts). The defrost adopts a proprietary self-adaptive logic, which features the monitoring of numerous operational parameters. This allows to reduce the number and duration of the defrost cycles, with a benefit for the overall energy efficiency.

Packaged

WISDOM-R 0101÷1204

Reversible rooftop unit, with heat recovery for medium crowding applications

43,0 - 422 kWUnit DescriptionUnit for outdoor installation, reversible and direct expansion for the air conditioning, with scroll compressors running on R410A, sandwich panel with thickness of 42mm, aluminium frame, base made in pre-painted galvanized steel profiles and centrifugal fan section. The standard execution is FCC (Centrifugal Free-Cooling with supply and return fans).

Page 309: Products Guide V01 - ParagonEfficient project management thanks to Climaveneta as unique project leader. Complete and specialized Organization Climaveneta qualifies itself for the

311

Minimum clearance required0101-0302 0352-1204

Switchboard side mm 1500 0Condensation coil side mm 2000 0

Note:

1 Cooling: External 35°C 50% r.h. / Internal 27°C 47% r.h. / Mix 50 %

2 Heating: External 7°C 87% r.h. / Internal 20°C 50% r.h. / Mix 50 %

3 ESP for standard configuration (optional accessories not included/calculated)

4 Sound power on the basis of measurements made in compliance with ISO 3744.

5 Sound pressure in open field conditions on reflecting surface. Condensing coil side average value at 1 metre from the surface and at 1 m height in relation to the unit supporting base.

Models 0364 0404 0454 0504 0604 0704 0804 0904 1004 1104 1204COOLING ONLYCooling capacity + Recovery (1) kW 139 157 188 206 230 263 313 341 380 402 422Sensible cooling capacity + Recovery (1)

kW 95,7 108 125 138 156 196 235 262 282 290 297

Compressor power input (1) kW 28,4 36,3 40,8 45,9 54,2 63,1 70,4 81,5 87,5 95,2 108HEATING ONLYHeating capacity + Recovery (2) kW 134 152 179 203 222 262 310 337 372 404 437Compressors power input (2) kW 21,8 26,8 30,7 36,3 39,3 48,6 53,6 59,6 65 72,9 84,4OUTLET FANSSupply air flow rate m3/h 21000 23500 27000 29000 32000 45000 50000 54000 56000 56000 56000Available static pressure (3) Pa 350 440 240 370 460 290 365 200 370 370 370Power Input kW 8 11 8 11 15 12 16 22 30 30 30SUCTION FANS/BLOWERSNominal air flow m3/h 21000 23500 27000 29000 32000 45000 50000 54000 56000 56000 56000Useful static head (3) Pa 150 150 125 189 258 295 380 200 450 450 450Power Input kW 6 8 6 8 11 12 16 22 30 30 30COMPRESSORSNo. Compressors/No. Circuits N. 4/2 4/2 4/2 4/2 4/2 4/2 4/2 4/2 4/2 4/2 4/2NOISE LEVELSSound power (4) dB(A) 88 88 94 94 94 * * * * * *Sound pressure (5) dB(A) 71 71 76 76 76 * * * * * *SIZEA mm 6950 6950 6950 6950 6950 11080 11080 11080 11080 11080 11080B mm 2330 2330 2340 2340 2340 2330 2330 2330 2330 2330 2330H mm 1820 1820 2380 2380 2380 2350 2350 2350 2350 2350 2350Operating weight kg 2550 2640 3240 3350 3490 5470 5730 5730 5870 6090 6100

WISDOM-R / BModels 0101 0121 0151 0102 0122 0152 0182 0202 0252 0302 0352COOLING ONLYCooling capacity + Recovery (1) kW 43 51,5 59,7 42,6 51,8 61 68,4 83,2 107 115 135Sensible cooling capacity + Recovery (1)

kW 29 34 39,5 28,8 34 41 47,4 56,4 71,6 79,5 90,9

Compressor power input (1) kW 8,40 11,9 12,9 8,49 13 13,3 15 17,8 23,6 27,6 29,9HEATING ONLYHeating capacity + Recovery (2) kW 41,7 53,2 58,2 40,9 54 59,6 66 80,1 103 113 132Compressors power input (2) kW 6,81 9,59 10,1 6,61 10,2 10,3 10,8 13,6 17,5 19,8 22,7OUTLET FANSSupply air flow rate m3/h 6500 7800 8500 6500 7800 8600 10500 13000 15500 17500 21000Available static pressure (3) Pa 264 314 230 264 314 210 365 240 275 330 350Power Input kW 1,50 2,20 2,20 1,50 2,20 2,20 4 3 4,40 6 8SUCTION FANS/BLOWERSNominal air flow m3/h 6500 7800 8500 6500 7800 8600 10500 13000 15500 17500 21000Useful static head (3) Pa 194 223 194 194 223 188 235 159 150 200 150Power Input kW 1,10 1,50 1,50 1,10 1,50 1,50 2,20 2,20 3 4,40 6COMPRESSORSNo. Compressors/No. Circuits N. 1/1 1/1 1/1 2/2 2/2 2/2 2/2 2/2 2/2 2/2 2/2NOISE LEVELSSound power (4) dB(A) 79 79 79 79 79 79 79 85 85 85 88Sound pressure (5) dB(A) 63 63 63 63 63 63 63 68 68 68 71SIZEA mm 5250 5250 5250 5250 5250 5250 5250 6450 6450 6450 6450B mm 1780 1780 1780 1780 1780 1780 1780 2330 2330 2330 2330H mm 1640 1640 1640 1640 1640 1640 1640 1790 1790 1790 1790Operating weight kg 1500 1540 1580 1500 1540 1610 1650 2190 2270 2330 2450

COOLINGHEATINGFREE COOLING

r HFCR-410A

SCROLLAXIALCENTRIFUGALPLATE

H

B

A

Page 310: Products Guide V01 - ParagonEfficient project management thanks to Climaveneta as unique project leader. Complete and specialized Organization Climaveneta qualifies itself for the

312

Main accessoriesHot gas post heating

CO2 control sensor for air quality

High efficiency filters: electronic or rigid pocket F7

Enthalpy free-cooling

Heating resource: hot water coil, electrical heater, burner methane gasSet-up for remote connectivity with ModBus/Echelon protocol cards

Remote keyboard (distance to 200m and to 500m)

FeaturesREFRIGERANT GAS R410A

The use of R410A has resulted in units offering better energy efficiency in full respect for the environment (ODP = 0).

STATIC RECOVERY WITH CROSS FLOWS

The air/air cross flow exchangery allows a constant and efficient exhaust airflow energy recovery. The excellent efficiency values (more than 50%) in winter conditions and no power consumption (there are no moving parts) give a concrete energy and economic saving.

COMFORT

The wide working field and the accurate designed of the unit ensure optimum capacities and guaranty comfort, with a continuous and constant bringing in of thermal load also in the more onerous thermohygrometric conditions.

SAFE USE

The refrigerant piping and the regulation devices are put in suitable space, splitted from the air treatment section. This means a lower accidental risk to contaminate the indoor environment and moreover allowing the thermostatic valve adjustment while the unit is on.

FLEXIBILITY

Climaveneta offers units with innumerable choices for the supply and return airflows directions.

VersionsB base version

CommandsAIR3000The controller AIR3000 offers advanced functions and algorithms. The keypad is generously sized with full operating status display. The controls and detailed LCD make access to unit settings easy and safe. Temperature regulation is based on step-wise proportional logic referring to the return air temperature. The diagnostics includes full management of alarms with the black-box and alarm logging functions for enhanced analysis of the unit operation. Supervision can be easily developed via proprietary devices or the integration in third party systems by means of the most common protocols as ModBus, Echelon LonWorks. Compatibility with the remote keyboard managing up to 10 units. Availability of an internal real time clock for operation scheduling (4-day profiles with 10 hour belts).

Packaged

WISDOM-T-R 0101÷1204

Cooling only rooftop unit, with heat recovery for medium crowding applications

43,5 - 425 kWUnit DescriptionUnit for outdoor installation, reversible and direct expansion for the air conditioning, with scroll compressors running on R410A, sandwich panel with thickness of 42mm, aluminium frame, base made in pre-painted galvanized steel profiles and centrifugal fan section. The standard execution is FCC (Centrifugal Free-Cooling with supply and return fans).

Page 311: Products Guide V01 - ParagonEfficient project management thanks to Climaveneta as unique project leader. Complete and specialized Organization Climaveneta qualifies itself for the

313

Minimum clearance required0101-1204

Switchboard side mm 1500Condensation coil side mm 2000

Note:

1 Cooling: External 35°C 50% r.h. / Internal 27°C 47% r.h. / Mix 50 %

2 ESP for standard configuration (optional accessories not included/calculated)

3 Sound power on the basis of measurements made in compliance with ISO 3744.

4 Sound pressure in open field conditions on reflecting surface. Condensing coil side average value at 1 metre from the surface and at 1 m height in relation to the unit supporting base.

Models 0364 0404 0454 0504 0604 0704 0804 0904 1004 1104 1204COOLING ONLYCooling capacity + Recovery (1) kW 135 158 189 208 233 265 315 340 382 404 425Sensible cooling capacity + Recovery (1)

kW 94,9 109 125 139 156 196 236 254 283 291 296

Compressor power input (1) kW 30,6 35,5 40,1 45,1 53,1 61,7 69,2 79,3 85,8 93,9 106OUTLET FANSSupply air flow rate m3/h 21000 23500 27000 29000 32000 45000 50000 54000 56000 56000 56000Available static pressure (2) Pa 350 440 240 370 460 290 365 200 370 370 370Power Input kW 8 11 8 11 15 12 16 22 30 30 30SUCTION FANS/BLOWERSNominal air flow m3/h 21000 23500 27000 29000 32000 45000 50000 54000 56000 56000 56000Useful static head (2) Pa 150 150 125 189 258 295 380 200 450 450 450Power Input kW 6 8 6 8 11 12 16 22 30 30 30COMPRESSORSNo. Compressors/No. Circuits N. 4/2 4/2 4/2 4/2 4/2 4/2 4/2 4/2 4/2 4/2 4/2NOISE LEVELSSound power (3) dB(A) 88 88 94 94 94 * * * * * *Sound pressure (4) dB(A) 71 71 76 76 76 * * * * * *SIZEA mm 6950 6950 6950 6950 6950 11080 11080 11080 11080 11080 11080B mm 2330 2330 2340 2340 2340 2330 2330 2330 2330 2330 2330H mm 1820 1820 2380 2380 2380 2350 2350 2350 2350 2350 2350Operating weight kg 2550 2640 3240 3350 3490 5470 5730 5730 5870 6090 6100

WISDOM-T-R / BModels 0101 0121 0151 0102 0122 0152 0182 0202 0252 0302 0352COOLING ONLYCooling capacity + Recovery (1) kW 43,5 52 60,1 42,9 52,5 59,3 69,1 83,6 103 117 135Sensible cooling capacity + Recovery (1)

kW 29,1 34,1 39,7 28,9 34,3 40,5 47,6 56,6 70,5 79,9 90,9

Compressor power input (1) kW 8,30 11,6 12,7 8,30 12,6 14 14,7 17,4 25,2 27,1 29,9OUTLET FANSSupply air flow rate m3/h 6500 7800 8500 6500 7800 8600 10500 13000 15500 17500 21000Available static pressure (2) Pa 264 314 230 264 314 210 365 240 275 330 350Power Input kW 1,50 2,20 2,20 1,50 2,20 2,20 4 3 4,40 6 8SUCTION FANS/BLOWERSNominal air flow m3/h 6500 7800 8500 6500 7800 8600 10500 13000 15500 17500 21000Useful static head (2) Pa 194 223 194 194 223 188 235 159 150 200 150Power Input kW 1,10 1,50 1,50 1,10 1,50 1,50 2,20 2,20 3 4,40 6COMPRESSORSNo. Compressors/No. Circuits N. 1/1 1/1 1/1 2/2 2/2 2/2 2/2 2/2 2/2 2/2 2/2NOISE LEVELSSound power (3) dB(A) 79 79 79 79 79 79 79 85 85 85 88Sound pressure (4) dB(A) 63 63 63 63 63 63 63 68 68 68 71SIZEA mm 5250 5250 5250 5250 5250 5250 5250 6450 6450 6450 6450B mm 1780 1780 1780 1780 1780 1780 1780 2330 2330 2330 2330H mm 1640 1640 1640 1640 1640 1640 1640 1790 1790 1790 1790Operating weight kg 1500 1540 1580 1500 1540 1610 1650 2190 2270 2330 2450

COOLINGFREE COOLING

r HFCR-410A

SCROLLAXIALCENTRIFUGALPLATE

H

B

A

Page 312: Products Guide V01 - ParagonEfficient project management thanks to Climaveneta as unique project leader. Complete and specialized Organization Climaveneta qualifies itself for the

314

Main accessoriesManual on/off valves

Two way motorized ON/OFF valve

Pressure-solenoid valve

Ambient air sensor

FeaturesREFRIGERANT GAS R410A

The use of R410A has resulted in units offering better energy efficiency in full respect for the environment (ODP = 0).

FUCNTIONALITY

The constructional simplicity ensures high reliability of use the minimum acoustic impact, also thanks to the special care given to insulation and aerodynamic profiles of the air supply area.

EFFICIENCY

The use of the top quality parts ensures maximum operating efficiency in all situations of plant design requirement.

COMPACTNESS

Units with reduced height making them especially suitable for installation in suspended ceilings and for ducted supply and return.

INSTALLATION AND SERVICING

The installation is simply for the reduced dimensions and the limited weight, while the servicing is made easier because all parts can be reached by removing just one panel.

VersionsB base version

CommandsS3The S3 controller features ease of use and nice design. The regulation is reliable thanks to the algorithms developed and to the availability of a multi-level menu with differentiated access modes. The controller includes the control board, mounted in the unit, the user interface with keypad and LCD display, with 4 lines, to be placed in the room (supplied separately and mandatory) and a remote air probe for air duct. The user interface allows the language selection (Italian, English, German). The diagnostics includes a complete alarm management, with the “black-box” and alarm logging functions for enhanced analysis of the unit operation. Availability of an internal real time clock for operation scheduling (4-day profiles with 10 hour belts). This allows to define operating status and modes. As standard, serial connectivity via ModBus protocol is featured, allowing the supervision by proprietary devices or the integration in third party systems. Supervision can be also implemented via optional protocols (Bacnet or Echelon LonWorks).

Packaged

WET-RMT 0015÷0101

WET line unit for water loop systems, indoor installation

7,2 - 34,4 kWUnit DescriptionUnit for indoor installation (in ceiling mounted or inserted behind a suspended ceiling), reversible and direct expansion for the air conditioning, with scroll compressors running on R410A. Panels and frame in hot-dip galvanised sheet steel, electric centrifugal supply fan. Hydraulic and electrical connections are simple thanks to the compact size and reduced weight of the units; maintenance is simple as all the components can be reached by removing just one panel.

Page 313: Products Guide V01 - ParagonEfficient project management thanks to Climaveneta as unique project leader. Complete and specialized Organization Climaveneta qualifies itself for the

315

Minimum clearance required0015-0101

Switchboard side mm 0Raising points side mm 0

Note:

1 Cooling: Indoor air 27°C 47% R.H. / Water loop temperature IN 29°C OUT 35°C

2 Heating: Indoor air 20°C 50% R.H. / Water loop temperature OUT 15°C

3 ESP for standard configuration (optional accessories not included/calculated)

4 Sound power measured in standard operating conditions without air ducts.

WET-RMT / BModels 0015 0021 0031 0041 0061 0065 0071 0081 0091 0101COOLING ONLYCooling capacity (1) kW 7,20 9 11,7 14,3 17,3 9 23,3 25,5 29,3 34,4Sensible cooling capacity (1) kW 5,83 7,29 9,48 11,6 14 16,4 18,9 20,7 23,7 27,9Compressors power input (1) kW 1,60 1,90 2,40 3 3,60 4,20 4,80 5,30 5,90 6,90HEATING ONLYHeating capacity (2) kW 7 8,80 11,2 13,8 16,5 19,4 22,2 24,4 27,9 32,6Compressors power input (2) kW 1,80 2,10 2,70 3,30 3,90 4,50 5,10 5,60 6,30 7,40PLATE EXCHANGERWater flow m3/h 1,26 1,56 2,02 2,48 3 3,50 4,03 4,42 5,05 5,93INTERNAL FANSAirflow rate m3/h 1300 1600 2300 2700 3100 3600 4200 4600 5200 6100Available static pressure (3) Pa 100 100 100 100 120 120 120 120 120 120Power Input kW 0,24 0,24 0,50 0,50 0,50 0,50 0,74 0,73 0,74 0,74COMPRESSORSNo. Compressors/No. Circuits N. 1/1 1/1 1/1 1/1 1/1 1/1 1/1 1/1 1/1 1/1NOISE LEVELSSound power (4) dB(A) 67 69 71 72 73 74 74 76 77 78SIZEA mm 900 900 955 955 1092 1092 1135 1135 1455 1455B mm 705 705 972 972 1069 1069 1114 1114 1135 1135H mm 450 450 500 500 573 573 663 663 732 732Operating weight kg. 103 111 123 155 245 - 255 - 293 310

COOLINGHEATING

r HFCR-410A

SCROLLCENTRIFUGAL

A B

H

Page 314: Products Guide V01 - ParagonEfficient project management thanks to Climaveneta as unique project leader. Complete and specialized Organization Climaveneta qualifies itself for the

316

Main accessoriesEnthalpy free-cooling

CO2 control sensor for air quality

Hot gas post heating

Set-up for remote connectivity with ModBus/Echelon protocol cards

Remote keyboard (distance to 200m and to 500m)

High efficiency filters: electronic or rigid pocket F7

FeaturesVARIABLE AIRFLOW FOR AIR TREATMENT SECTION

The specific VAir function is used to deliver air according to the flow of hot-cold air and many other operating parameters. This offers significant reductions in the power input of the fans.

REFRIGERANT GAS R410A

The use of R410A has resulted in units offering better energy efficiency in full respect for the environment (ODP = 0).

ROTARY-TYPE ENTHALPY RECOVERY

The exclusive rotary recovery allows sensible and latent energy from the exhaust airflow both in winter and summer conditions. The latent recovery, in particular, is important in dehumidification in summer and humidification in winter for indoor, with very high efficiency values.

PLUG-FAN VENTILATION

The plug-fan supply and return fan section joins the high efficacy ventilation with a quicker and easier electric and aerolics installation of the unit.

SAFE USE

The refrigerant piping and the regulation devices are put in suitable space, splitted from the air treatment section. This means a lower accidental risk to contaminate the indoor environment and moreover allowing the thermostatic valve adjustment while the unit is on.

ConfigurationsPC function for constant water flow system

PV function for variable water flow system

PP function for disposable water system

VersionsB base version

CommandsAIR3000SEThe AIR3000SE controller offers advanced functions and algorithms. The keypad features functional controls and a complete LCD display that allows assessment and intervention on the unit by means of a multi-level menu with selectable user´s language. The presence of the programmable timer allows the creation of an operating profile containing up to 4 typical days and 10 time bands. The proportional step heat adjustment is based on the return temperature; proportional-integral adjustment can also be set. Functions include adjustment of available resources, ambient humidity, thermal or enthalpic (optional) free-cooling and delivery temperature limitation. The specific VAir function is used to deliver air according to the flow of hot-cold air and many other operating parameters. This offers significant reductions in the power input of the fans. The function can be selected from a parameter, it operates within settable flow values and is compatible with the adjusted rotation speed, adjusted flow and adjusted pressure ventilation methods. It also guarantees any differences required between return and delivery airflows. The diagnostics comprises a complete alarm management system, including black box (via PC) functions and an alarm log (via display or also PC) for optimised analysis of unit performance. Supervision can be easily developed via proprietary devices or the integration in third party systems by means of the most common protocols as ModBus, Bacnet, Bacnet-over-IP, Echelon LonWorks protocols. Compatibility with the remote keyboard managing up to 10 units.

Packaged

WET ENTHALPY 0102÷0604

High efficiency WET line unit for water loop systems, with enthalpy recovery, outdoor installation

50,6 - 262 kWUnit DescriptionAutonomous rooftop unit, water/air reversible, for the thermohygrometric treatment, the filtration and the air change in wide areas. Both winter and summer operating conditions, double refrigerant circuit, scroll compressors with refrigerant R410A. Air treatment section with plug-fans and direct expansion finned internal exchangers. Enthalpic rotary heat recovery. Management of air treatment section according to the requested heating or cooling capacity by the Vair function.

Page 315: Products Guide V01 - ParagonEfficient project management thanks to Climaveneta as unique project leader. Complete and specialized Organization Climaveneta qualifies itself for the

317

Minimum clearance required0102-0604

Switchboard side mm 1500Raising points side mm 2000

Note:

1 Cooling: Outdoor air 35°C 50% R.H. / Indoor air 27°C 47% R.H. / Mix 30% / Water loop temperature IN 29°C OUT 35°C

2 Heating: Outdoor air 7°C 87% R.H. / Indoor air 20°C 50% R.H. / Mix 30% / Water loop temperature OUT 10°C

3 ESP for standard configuration (optional accessories not included/calculated)

4 Sound power measured in standard operating conditions without air ducts.

WET ENTHALPY / BModels 0102 0122 0152 0182 0202 0252 0302 0352 0364 0404 0454 0504 0604COOLING ONLYCooling capacity + Recovery (1) kW 50,6 62,5 71,7 83,8 103 130 143 171 175 193 211 241 262Sensible cooling capacity + Recovery (1)

kW 32,4 39,8 45 53,9 64,6 80,7 90,5 109 110 121 138 153 168

Compressor power input (1) kW 6,90 9,20 10,8 12,9 13,9 18,1 20,5 24,4 26,1 28 32 36 41,2HEATING ONLYHeating capacity + Recovery (2) kW 50,7 64,8 74 86,7 102 131 146 174 178 199 219 251 279Compressors power input (2) kW 7,90 11,6 12,4 14,8 15,9 19,9 22,9 25,8 28 31,7 39,9 41,2 49,2PLATE EXCHANGERWater flow m3/h 6,30 8,03 9,40 11 12,8 16,6 18,4 22,2 23 25,4 27,8 32,3 35,6OUTLET FANSSupply air flow rate m3/h 6500 7800 8600 10500 13000 15500 17500 21000 21000 23000 27000 29000 32000Available static pressure (3) Pa 250 250 250 250 250 250 250 250 250 250 250 250 250Power Input kW 1,50 1,96 2,24 3,18 2,74 3,68 4,66 5,22 5,22 6,38 7,84 9,06 11,3SUCTION FANS/BLOWERSNominal air flow m3/h 6500 7800 8600 10500 13000 15500 17500 21000 21000 23000 27000 29000 32000Useful static head (3) Pa 150 150 150 150 150 150 150 150 150 150 150 150 150Power Input kW 1,04 1,62 1,92 2,82 2 2,68 3,98 3,66 3,66 4,50 4,42 5,16 6,82COMPRESSORSNo. Compressors/No. Circuits N. 2/2 2/2 2/2 2/2 2/2 2/2 2/2 2/2 4/2 4/2 4/2 4/2 4/2NOISE LEVELSSound power (4) dB(A) 88 89 90 91 94 94 94 95 95 96 97 97 98SIZEA mm 3760 3760 3760 3760 4035 4035 4035 4830 4830 4830 5200 5200 5200B mm 1780 1780 1780 1780 2330 2330 2330 2330 2330 2330 2330 2330 2330H mm 1490 1490 1490 1490 2240 2240 2240 2240 2240 2240 2240 2240 2240Operating weight kg 1430 1460 1520 1540 2430 2480 2540 3000 3110 3130 3620 3710 3760

COOLINGHEATINGFREE COOLINGSCROLLPLUG FANROTARY

Page 316: Products Guide V01 - ParagonEfficient project management thanks to Climaveneta as unique project leader. Complete and specialized Organization Climaveneta qualifies itself for the

318

Main accessoriesHot gas post heating

CO2 control sensor for air quality

High efficiency filters: electronic or rigid pocket F7

Enthalpy free-cooling

Set-up for remote connectivity with ModBus/Echelon protocol cards

Remote keyboard (distance to 200m and to 500m)

FeaturesREFRIGERANT GAS R410A

The use of R410A has resulted in units offering better energy efficiency in full respect for the environment (ODP=0).

COMFORT

The wide working field and the accurate designed of the unit ensure optimum capacities and guaranty comfort, with a continuous and constant bringing in of thermal load also in the more onerous thermohygrometric conditions.

SAFE USE

The refrigerant piping and the regulation devices are put in suitable space, splitted from the air treatment section. This means a lower accidental risk to contaminate the indoor environment and moreover allowing the thermostatic valve adjustment while the unit is on.

FLEXIBILITY

Climaveneta offers units with innumerable choices for the supply and return airflows directions.

ConfigurationsPC function for constant water flow system

PV function for variable water flow system

PP function for disposable water system

VersionsB base version

CommandsAIR3000The controller AIR3000 offers advanced functions and algorithms. The keypad is generously sized with full operating status display. The controls and detailed LCD make access to unit settings easy and safe. Temperature regulation is based on step-wise proportional logic referring to the return air temperature. The diagnostics includes full management of alarms with the black-box and alarm logging functions for enhanced analysis of the unit operation. Supervision can be easily developed via proprietary devices or the integration in third party systems by means of the most common protocols as ModBus, Echelon LonWorks. Compatibility with the remote keyboard managing up to 10 units. Availability of an internal real time clock for operation scheduling (4-day profiles with 10 hour belts).

Packaged

WET-RTF 0102÷1204

WET line unit for water loop systems, outdoor installation

37,2 - 396 kWUnit DescriptionUnit for indoor installation, reversible and direct expansion for the air conditioning, with scroll compressors running on R410A, sandwich panel with thickness of 42mm, aluminium frame, base made in pre-painted galvanized steel profiles and centrifugal fan section. The unit in standard version, STD, can treat recirculating-only air; other available executions (optionals) are MIX (return air and fresh air mix), FCS (Standard Free-Cooling with supply fans) or FCC (Centrifugal Free-Cooling with supply and return fans).

Page 317: Products Guide V01 - ParagonEfficient project management thanks to Climaveneta as unique project leader. Complete and specialized Organization Climaveneta qualifies itself for the

319

Minimum clearance required0102-1204

Switchboard side mm 1500Raising points side mm 2000

Note:

1 Cooling: Indoor air 27°C 47% R.H. / Water loop temperature IN 29°C OUT 35°C

2 Heating: Indoor air 20°C 50% R.H. / Water loop temperature OUT 10°C

3 ESP for standard configuration (optional accessories not included/calculated)

4 Sound power on the basis of measurements made in compliance with ISO 3744.

5 Unit in standard configuration/execution, without optional accessories

Models 0454 0504 0604 0704 0804 0904 1004 1104 1204COOLING ONLYCooling capacity (1) kW 170 187 215 243 288 314 352 375 396Sensible cooling capacity (1) kW 102 131 150 172 207 224 250 258 266Compressor power input (1) kW 32,1 36,4 40,4 48,2 55,6 61,7 67,4 74,5 82,8HEATING ONLYHeating capacity (2) kW 199 225 252 283 333 368 410 442 488Compressors power input (2) kW 37,2 44,4 48,7 61,5 66,4 76,9 82,8 92,4 109CONDENSERWater flow rate mc/h 28,9 32 36,6 41,8 49,2 53,8 60,1 64,4 68,7OUTLET FANSSupply air flow rate m3/h 27000 29000 32000 45000 50000 54000 56000 56000 56000Available static pressure (3) Pa 215 261 333 235 255 400 290 290 290Power Input kW 6 8 11 12 16 22 30 30 30COMPRESSORSNo. Compressors/No. Circuits N. 4/2 4/2 4/2 4/2 4/2 4/2 4/2 4/2 4/2NOISE LEVELS (4)Sound power dB(A) 92 92 92 * * * * * *SIZEA (5) mm 2470 2470 2470 5000 5000 5000 5000 5000 5000B (5) mm 2330 2330 2330 2330 2330 2330 2330 2330 2330H (5) mm 2240 2240 2240 2240 2240 2240 2240 2240 2240Operating weight (5) kg 1570 1630 1750 2770 3000 3200 3250 3300 3350

WET-RTF / BModels 0102 0122 0152 0182 0202 0252 0302 0352 0364 0404COOLING ONLYCooling capacity (1) kW 37,2 46,5 54,6 62,3 73,8 96,3 106 121 125 144Sensible cooling capacity (1) kW 27,9 32,6 39,6 45 53 69,3 75,7 84,5 90,2 102Compressor power input (1) kW 6,85 9,24 10,7 11,3 13,8 18,3 20,4 21,6 22,6 27,5HEATING ONLYHeating capacity (2) kW 42,6 55,2 64,2 71,9 84,5 113 126 144 146 173Compressors power input (2) kW 7,87 11,9 12,2 13,1 16,1 21,1 24,9 25,9 26,3 33,5CONDENSERWater flow rate mc/h 6,32 7,99 9,36 10,6 12,6 16,4 18,1 20,4 21,1 24,5OUTLET FANSSupply air flow rate m3/h 6500 7800 8600 10500 13000 15500 17500 21000 21000 23500Available static pressure (3) Pa 220 219 315 261 208 202 269 271 271 303Power Input kW 1,10 1,50 2,20 3 2,20 3 4,40 6 6 8COMPRESSORSNo. Compressors/No. Circuits N. 2/2 2/2 2/2 2/2 2/2 2/2 2/2 2/2 4/2 4/2NOISE LEVELS (4)Sound power dB(A) 78 76 76 76 82 82 82 87 87 87SIZEA (5) mm 2200 2200 2200 2200 2470 2470 2470 2470 2470 2470B (5) mm 1780 1780 1780 1780 2330 2330 2330 2330 2330 2330H (5) mm 1490 1490 1490 1490 1640 1640 1640 1640 1640 1640Operating weight (5) kg 710 780 790 810 1030 1080 1110 1250 1340 1350

COOLINGHEATINGFREE COOLING

r HFCR-410A

SCROLLCENTRIFUGAL

Page 318: Products Guide V01 - ParagonEfficient project management thanks to Climaveneta as unique project leader. Complete and specialized Organization Climaveneta qualifies itself for the

320

Main accessoriesHot gas post heating

CO2 control sensor for air quality

High efficiency filters: electronic or rigid pocket F7

Enthalpy free-cooling

Set-up for remote connectivity with ModBus/Echelon protocol cards

Remote keyboard (distance to 200m and to 500m)

FeaturesREFRIGERANT GAS R410A

The use of R410A has resulted in units offering better energy efficiency in full respect for the environment (ODP = 0).

STATIC RECOVERY WITH CROSS FLOWS

The air/air cross flow exchangery allows a constant and efficient exhaust airflow energy recovery. The excellent efficiency values (more than 50%) in winter conditions and no power consumption (there are no moving parts) give a concrete energy and economic saving.

COMFORT

The wide working field and the accurate designed of the unit ensure optimum capacities and guaranty comfort, with a continuous and constant bringing in of thermal load also in the more onerous thermohygrometric conditions.

SAFE USE

The refrigerant piping and the regulation devices are put in suitable space, splitted from the air treatment section. This means a lower accidental risk to contaminate the indoor environment and moreover allowing the thermostatic valve adjustment while the unit is on.

FLEXIBILITY

Climaveneta offers units with innumerable choices for the supply and return airflows directions.

ConfigurationsPC function for constant water flow system

PV function for variable water flow system

PP function for disposable water system

VersionsB base version

CommandsAIR3000The controller AIR3000 offers advanced functions and algorithms. The keypad is generously sized with full operating status display. The controls and detailed LCD make access to unit settings easy and safe. Temperature regulation is based on step-wise proportional logic referring to the return air temperature. The diagnostics includes full management of alarms with the black-box and alarm logging functions for enhanced analysis of the unit operation. Supervision can be easily developed via proprietary devices or the integration in third party systems by means of the most common protocols as ModBus, Echelon LonWorks. Compatibility with the remote keyboard managing up to 10 units. Availability of an internal real time clock for operation scheduling (4-day profiles with 10 hour belts).

Packaged

WET-RTF-R 0102÷1204

WET line unit for water loop systems, with heat recovery, outdoor installation

44,8 - 468 kWUnit DescriptionUnit for outdoor installation, reversible and direct expansion for the air conditioning, with scroll compressors running on R410A, sandwich panel with thickness of 42mm, aluminium frame, base made in pre-painted galvanized steel profiles and centrifugal fan section. The standard execution is FCC (Centrifugal Free-Cooling with supply and return fans).

Page 319: Products Guide V01 - ParagonEfficient project management thanks to Climaveneta as unique project leader. Complete and specialized Organization Climaveneta qualifies itself for the

321

Minimum clearance required0102-1204

Switchboard side mm 1500Raising points side mm 2000

Note:

1 Cooling: Outdoor air 35°C 50% R.H. / Indoor air 27°C 47% R.H. / Mix 50% / Water loop temperature IN 29°C OUT 35°C

2 Heating: Outdoor air 7°C 87% R.H. / Indoor air 20°C 50% R.H. / Mix 50% / Water loop temperature OUT 10°C

3 ESP for standard configuration (optional accessories not included/calculated)

Models 0454 0504 0604 0704 0804 0904 1004 1104 1204COOLING ONLYCooling capacity + Recovery (1) kW 200 219 250 297 348 382 420 446 468Sensible cooling capacity + Recovery (1)

kW 145 155 177 211 249 278 297 305 311

Compressor power input (1) kW 32,2 36,3 40,6 49,6 57,1 64,2 69,5 76,3 85,2HEATING ONLYHeating capacity + Recovery (2) kW 234 263 292 334 390 429 473 505 552Compressors power input (2) kW 35,7 42,7 46,8 57,2 61,8 70,1 76,7 85,4 100PLATE EXCHANGERWater flow m3/h 28,9 32 36,6 41,8 49,2 53,8 60,1 64,4 68,7OUTLET FANSSupply air flow rate m3/h 27000 29000 32000 45000 50000 54000 56000 56000 56000Available static pressure (3) Pa 240 370 460 290 365 200 370 370 370Power Input kW 8 11 15 12 16 22 30 30 30SUCTION FANS/BLOWERS (3)Nominal air flow m3/h 27000 29000 32000 45000 50000 54000 56000 56000 56000Useful static head Pa 125 189 258 295 380 200 450 450 450Power Input kW 6 8 11 12 16 22 30 30 30COMPRESSORSNo. Compressors/No. Circuits N. 4/2 4/2 4/2 4/2 4/2 4/2 4/2 4/2 4/2NOISE LEVELSSound power dB(A) 94 94 94 * * * * * *SIZEA mm 5470 5470 5470 9500 9500 9500 9500 9500 9500B mm 2330 2330 2330 2330 2330 2330 2330 2330 2330H mm 2240 2240 2240 2240 2240 2240 2240 2240 2240Operating weight kg 2690 2740 2830 4450 4650 4700 4780 5000 5050

WET-RTF-R / BModels 0102 0122 0152 0182 0202 0252 0302 0352 0364 0404COOLING ONLYCooling capacity + Recovery (1) kW 44,8 55,5 65,1 74,4 89,4 114 126 143 147 169Sensible cooling capacity + Recovery (1)

kW 33,8 39,5 47,9 54,5 66,1 85,8 91,3 101 107 122

Compressor power input (1) kW 6,95 9,24 10,6 11,2 13,7 18,4 20,3 21,7 22,5 27,3HEATING ONLYHeating capacity + Recovery (2) kW 52,1 66 76,8 85,8 103 135 150 166 172 202Compressors power input (2) kW 7,48 11,5 11,6 12,6 15,6 20,3 24 23,9 25,2 32,2PLATE EXCHANGERWater flow m3/h 6,32 7,99 9,36 10,6 12,6 16,4 18,1 20,4 21,1 24,5OUTLET FANSSupply air flow rate m3/h 6500 7800 8600 10500 13000 15500 17500 21000 21000 23500Available static pressure (3) Pa 264 314 210 365 240 275 330 350 350 440Power Input kW 1,50 2,20 2,20 4 3 4,40 6 8 8 11SUCTION FANS/BLOWERS (3)Nominal air flow m3/h 6500 7800 8600 10500 13000 15500 17500 21000 21000 23500Useful static head Pa 194 223 188 235 159 150 200 150 150 150Power Input kW 1,10 1,50 1,50 2,20 2,20 3 4,40 6 6 8COMPRESSORSNo. Compressors/No. Circuits N. 2/2 2/2 2/2 2/2 2/2 2/2 2/2 2/2 4/2 4/2NOISE LEVELSSound power dB(A) 78 78 78 78 84 84 84 89 89 89SIZEA mm 4500 4500 4500 4500 5470 5470 5470 5470 5470 5470B mm 1780 1780 1780 1780 2330 2330 2330 2330 2330 2330H mm 1490 1490 1490 1490 1640 1640 1640 1640 1640 1640Operating weight kg 1300 1360 1370 1400 1860 1910 1940 2180 2230 2370

COOLINGHEATINGFREE COOLING

r HFCR-410A

SCROLLCENTRIFUGALPLATE

H

B

A

Page 320: Products Guide V01 - ParagonEfficient project management thanks to Climaveneta as unique project leader. Complete and specialized Organization Climaveneta qualifies itself for the

322

YSTEYSTEYSYY

Page 321: Products Guide V01 - ParagonEfficient project management thanks to Climaveneta as unique project leader. Complete and specialized Organization Climaveneta qualifies itself for the

323

EMSsystems

syste

ms

Page 322: Products Guide V01 - ParagonEfficient project management thanks to Climaveneta as unique project leader. Complete and specialized Organization Climaveneta qualifies itself for the

324

FeaturesOPTIONS

Integration in BMS /BAS via ModBus, Echelon LonTalk or Bacnet protocols

Modem or ADSL router

Log of main variables and alarm events

WebManager, with capabilities of remote access and optionale display of logged data charts.

VPF implementation.

Systems

MANAGER 3000

Group regulation device

Unit DescriptionManager3000 allows the regulation within a group of hydronic units. The controller features high-level algorithms and user interface. The controller is suitable for the management of 2- or 4-pipe systems, with regulation on one water circuit, for chiller- or heat pump units and relevant mode change-over, and also with regulation on two circuits, with independent set-points and parameters, thus exploiting the simultaneous supply of chilled- and hot water. The controller manages up to 8 units, with activation logic focused at the balancing of operation times and at the achievement of the highest energy efficiency. It is possible to define conditions of dynamic stand-by and priority as regards the units activation. It is also feasible the rotation among the systems units, also in cases of constant load. The alarm management is featured, with plain text descriptions and possible notification to remote recipients. Two relay outputs are available, associated to unit- and device alarms. The user interface allows a safe and easy use, thanks to its touch-screen display, back-lit 8.4” type. The multi-level menu features the language selection and differentiated access profiles(user and maintenance).The circuit temperatures and the status of both system- and unit- operation are displayed, via one overview page plus detailed pages. The regulation can be based on proportional- or proportional+integral logics, or also on a dead-band algorithm with dynamic adjustment, with relevant temperature inputs managed by the device. Features as set-point offset, also referred to the outdoor temperature, and demand limit are included, with relevant analog inputs. The device is integrated in the best way with the units, preventing simultaneous activations or resources and optimizing efficiency, overall inrush current values and also operation of water pumps possibly associated to the units. The WebManager option allows the access to the device and its settings, via any computer, with direct- or LAN-based connection, therefore also via internet resources; this is associated to the availability of historical charts for the main operating variables. The “Variable Primary Flow” option represents a unique regulation dedicated to hydronic systems with variable water flow. This represents a crucial contribution to the reduction of the costs related to the hydraulic plant and its operation. It is available as option the interface with the Demetra metering device: thus it is possible to acquire and log the values of the system units electric consumption, together with their operating status; this allows therefore to analyze the systems operating performances throughout time, in terms of both absorbed energy and cooling / heating capacities, consistently with the implementation of enhanced energy management policies for the building.

Models MANAGERmax number of managed units 8Management of hydronic units XRegulation on one water circuit XRegulation on two water circuits (4 pipe systems) XUser interface with display and commands, touchscreen, multi-language

X

Alarm management XManagement of stand-by, priority, rotation XSupervision via web pages (WebManager) optIntegration into BMS/BAS systems optAcquisition and log of the main operating variables

opt

Modem gprs or pstn, integrated optRouter ADSL, integrated optCompatibility with variable primary flow systems optCompatibility with metering device Demetra opt

Page 323: Products Guide V01 - ParagonEfficient project management thanks to Climaveneta as unique project leader. Complete and specialized Organization Climaveneta qualifies itself for the

325

FeaturesIntegration in BMS /BAS via ModBus, Echelon LonTalk or Bacnet protocols

Systems

SEQUENCER SEQUENCER÷SEQUENCER

Group regulation device

Unit DescriptionThe device allows the regulation within a group of hydronic units. The controller features a high-level algorithm (regulation profile GR2000). The controller is suitable for the management of 2-pipe systems, with regulation on one water circuit, for chiller- or heat pump units and relevant mode change-over. The controller manages up to 5 units, with activation logic focused at the balancing of operation times and at the achievement of the highest energy efficiency. It is possible to define conditions of dynamic stand-by and priority as regards the units activation. The alarm management, with one relay output, is available. On the LCD user interface the main variables, related to the system and the units, are displayed. The regulation can be based on proportional- or proportional+integral logics. The device is integrated in the best way with the units, preventing simultaneous activations of resources and optimizing the efficiency and the overall inrush current value.

Models SEQUENCERRegulation of multiple units, 1 water circuit XRegulation of multiple units, 2 water circuits Management of dynamic stand-by, priority, demand limit

X

Integration in bms / bas systems optManagement of hydronic units XMax number of devices 5User interface with display and commands XMonitoring of alarms and unit status X

Page 324: Products Guide V01 - ParagonEfficient project management thanks to Climaveneta as unique project leader. Complete and specialized Organization Climaveneta qualifies itself for the

326

Systems

DEMETRA

Metering device

Unit DescriptionThe new Demetra device represents the solution for the most evolved and up-to-date requirements concerning the energy management of HVAC hydronic systems Demetra (DEvice for Metering of Energy TRAnsfers) is associated to the Climaveneta devices, Manager3000 or FWS3000 and enables the metering of both electric energy consumption and cooling / heating performances. Demetra is compatible with hydronic systems with one or two hydraulic circuits. The combination of Manager3000 and Demetra represents the optimized integration between systems regulation and measurement of the benefits, energy-wise, arising from such regulation. With Demetra it is possible the acquisition, at selectable intervals, of the electric energy consumption for each unit, the water flow rates (optional, care of customer) and of the outdoor air temperature. These values are integrated with the operating status of each unit, as detected by Manager3000 or FWS3000 (on these devices, the options of USB key and compatibility with Demetra are required). Demetra is provided complete with power supply meters, associated to each unit belonging to the system. The flow rate meters, for each hydraulic circuit, are optional, care of customer. The enhanced features of this solution allow to obtain directly the cooling- and heating energy values supplied, according to the operation conditions detected on the units at each sampling. By this way, historical files are obtained, easily downloadable also via LAN / internet, thus enabling a deep and complete analysis of systems performances throughout time. In particular, the following data are managed: Electric energy consumption Cooling energy output, for the relevant water circuit Heating energy output, for the relevant water circuits Outdoor air temperature Water inlet- and outlet temperatures, for the relevant water circuits Water flow rate, for the relevant water circuits (optional, care of customer) Duration time for the different operating regimes, for each unit

Models DEMETRAmax number of managed units 8Management of hydronic units XMetering on one water circuit XMetering on two water circuits (4 pipe systems) XCompatibility with Manager3000 XCompatibility with FWS3000 X

Page 325: Products Guide V01 - ParagonEfficient project management thanks to Climaveneta as unique project leader. Complete and specialized Organization Climaveneta qualifies itself for the

327

FeaturesIntegration in bms / bas systems, with modbus protocol

Modem or ADSL router

Log of main variables and alarm events

Systems

FWS3

Supervisory device

Unit DescriptionSupervisory device for one Climaveneta unit. Supervision can be operated via any computer, with direct- or LAN-based connection. It is therefore achieved the internet-based management of the resources, thanks to the built-in web-server and to the availability of web pages specifically defined.The supervision achieved by this way does not require the installation of any additional software on the computer and utilizes the most common browsers. This allows the use of any computer connected to the network or web.A RS-485 serial connection is available for the communication with the slave device (hydronic unit: chiller or heat pump. Rooftop).The access to the supervision is easy and safe, thanks to the use of password. It is possible to visualize a complete list of unit operational variables: temperatures, humidity, indoor air quality, status of the unit. It is also available the display of alarms, with plain text descriptions and possible notification to remote recipient. The setting of the main operational parameters, for each unit, is also allowed: unit status, mode, set-point, time scheduling (based on 4 days, 10 time belts per day).

Models FWS3Supervision via web pages XIntegration in bms / bas systems optAccess via lan XManagement of rooftop- or wet units XManagement of hydronic units XMonitoring of alarms and unit status XRemote notification of alarms XLog of main regulation variables and alarm events optBuilt-in modem, gprs or pstn type optBuilt-in adsl router opt

Page 326: Products Guide V01 - ParagonEfficient project management thanks to Climaveneta as unique project leader. Complete and specialized Organization Climaveneta qualifies itself for the

328

FeaturesCustomization of the web pages

Application package dedicated to high-attendance or cinema applicationsApplication package dedicated to the energy metering and billing, with water-loop systems

Integration in bms / bas systems, with modbus protocol

Modem or ADSL router

Log of main variables and alarm events

Systems

FWS3000

Supervisory device

Unit DescriptionSupervisory device for a system composed of Climaveneta units. Supervision can be operated via any computer, with direct- or LAN-based connection. It is therefore achieved the internet-based management of the resources, thanks to the built-in web-server and to the availability of web pages specifically defined both for the overall system monitoring and the access to detailed information about each unit. The supervision achieved by this way does not require the installation of any additional software on the computer and utilizes the most common browsers. This allows the use of any computer connected to the network or web. A RS-485 serial connection is available for the communication with the slave devices, up to 15 connected units. FWS3000 is particularly effective for the supervision of systems composed of packaged or WET units. The access to the supervision is easy and safe, thanks to the use of password. It is possible to visualize a complete list of unit operational variables: temperatures, humidity, indoor air quality, status of the unit. This is associated to the availability of historical charts for the main operating variables. It is also available the display of alarms, with plain text descriptions and possible notification to remote recipient. The setting of the main operational parameters, for each unit, is also allowed: unit status, mode, set-point, time scheduling (based on 4 days, 10 time belts per day). Various levels of customization are offered, for both the web pages and connectivity-related functions. It is available as option the interface with the Demetra metering device: thus it is possible to acquire and log the values of the system units electric consumption, together with their operating status; this allows therefore to analyze the systems operating performances throughout time, in terms of both absorbed energy and cooling / heating capacities, consistently with the implementation of enhanced energy management policies for the building.

Models FSW3000max number of managed units 15Management of packaged or hydronic systems XAlarm management XSupervision via web pages XIntegration into BMS/BAS systems optAcquisition and log of the main operating variables

opt

Modem gprs or pstn, integrated optRouter ADSL, integrated optCompatibility with metering device Demetra opt

Page 327: Products Guide V01 - ParagonEfficient project management thanks to Climaveneta as unique project leader. Complete and specialized Organization Climaveneta qualifies itself for the

329

Page 328: Products Guide V01 - ParagonEfficient project management thanks to Climaveneta as unique project leader. Complete and specialized Organization Climaveneta qualifies itself for the

330

SYSTEMS

Centralised hydronic air-conditioning system for cooling, heating and domestic hot water production

DescriptionCentralized management and control system, via a user interface consisting in a compact PC for flush mounting, which features Touch Screen commands.Capability of control up to 224 devices (terminals, chillers or heat pumps, other components) for each serial network.

Standard functionsMANAGEMENTFor each terminal, provided with wall-mount or built-in controller, it is possible to select set-point, operation mode, fan speed. These settings can be further modified either locally, by acting on each controller, or in a centra-lized way, by acting on the touch-screen. For the water chillers and heat pumps, centralized access allows to switch the units on and off and selecting the operation mode.SUPERVISIONAt any moment it is possible to display via touch-screen the operation status of the terminals connected to the serial line. For each room: temperature, set-point, opera-tion mode are displayed. For the water chillers and heat pumps: operation mode, temperatures and possibly active alarms can be displayed.QUICK SETTINGSVia centralized access it is possible to switch all terminals on or off simultaneously; for the water chillers and heat pumps, it is allowed to select the set-point value, the ope-ration mode and to command the switch-on.TIMERA timer function is implemented, enabling to switch on or off the whole system or selected zones, with scheduling on daily and weekly basis.LIMITSAt local level, the setting ability can be limited, by disa-bling some or all functions of each controller (ventilation, operation mode), or reducing the adjustable range of set-point values to few degrees (e.g. ±1°C). By the same way, each controller can be disabled in order to prevent any change at local level and assign full control of the zone to the supervision.ECONOMY CONTACTLocal controllers of the terminals are provided with an Eco-nomy contact which, connected to voltage-free contacts of various types (room access badge, window contact, presence detector, etc.) thus allowing to manage an “eco-nomy” operation profile (minimum speed ventilation, set-point value increased in summer mode and decreased in winter mode). The operation profile is reset to normal by closing the contact.COMPONENTS MANAGEMENT It is furthermore possible to manage, by means of dedi-cated voltage-free contacts, the on-off switching of fur-ther components of the cooling / heating system, such as pumps, zone valves or boilers.

Products suitable to integrationHydronic terminals

Water chillers and heat pumps-

logues

Auxiliary components suitable to be managed via digital contact

Page 329: Products Guide V01 - ParagonEfficient project management thanks to Climaveneta as unique project leader. Complete and specialized Organization Climaveneta qualifies itself for the

331

Operation diagram

Note

1. StarTouch: Compact user interface panel, with a 5,7” TFT colour display, suitable for Windows CE-based applications. I/O board includes 2 USB connectors type A (host), 1 RJ45 connector for Ethernet 10/100, 1 DB9 connector for the RS232 serial port, screw terminals for the RS485 serial port, 1 USB connector client type.2. BusAdapter: Interface enabling the connection of the electronic controllers AT/ATW to a RS485 network; one interface required for each controller.3. AT: Plug-in control; features: on-off, operation mode, fan speed mode, set-point selection, economy contact, window contact, remote cool/heat, hot start and too-cool functions.4. ATW: Wall-mounted control; features: on-off, operation mode, fan speed mode, set-point selection, economy contact, window contact, remote cool/heat, hot start and too-cool functions.5. BusCE: kit including controller and BusAdapter; to be used when it is necessary to conceal both components, managing the terminal via supervision or infra-red remote control.6. IR: kit for the infra-red remote control composed of an infra-red receiver and associated remote keypad, which replicates all functions of the electronic controller.7. HSW7: Mini-chiller control; it can be directly integrated in the serial line via BusAdapter (standard on units: BRAT, BRAN, BRA, BRH, etc.).8. PowerBusCE: Interface enabling the connection of the auxiliary plant components (pumps, boilers, valves, etc.) and some type of chillers and heat pumps.9. Serial cable: Serial communication cable: 2-conductor twisted pair, shielded, cross section reference AWG22. For wiring length over 1.5 km, feasibility assessment is required.

This operation diagram is purely representative and qualitative. Refer to the available technical documentation for compatibility and connection mode.

Page 330: Products Guide V01 - ParagonEfficient project management thanks to Climaveneta as unique project leader. Complete and specialized Organization Climaveneta qualifies itself for the

332

AAA

Page 331: Products Guide V01 - ParagonEfficient project management thanks to Climaveneta as unique project leader. Complete and specialized Organization Climaveneta qualifies itself for the

333

AHUAHU

AH

U

Page 332: Products Guide V01 - ParagonEfficient project management thanks to Climaveneta as unique project leader. Complete and specialized Organization Climaveneta qualifies itself for the

334

FeaturesUNIT COMPLETE WITH REGULATION

The unit includes the controller for the regulation of all the parameters required for the air treatment. The electrical board is built-in and complete with wiring, while the components such as 3-way valves, probes, damper motors and humidifiers (optional) are provided factory-mounted and wired

CE MARKING

As the unit does not require any further on-site intervention upon it, Climaveneta provides Wizard Automatic completed with CE marking, Class A

REDUCED TIMING

Thanks to the use of a unit ready to operate without any further intervention, the commissioning timing results strongly reduced.

SAFETY AND RELIABILITY

Climaveneta becomes the single contact reference for any malfunctioning related to the unit.

MINIMAL SYSTEM START-UP COSTS

The on-site placement of a “plug & play” unit remarkably reduces the use of skilled labour, associated to the commissioning of a traditional air handling unit, thus reducing the costs

CommandsAHU3000The AHU3000 controller is featured as option for the air handling units. It offers functions and regulations able to satisfy the numerous combinations possible with these units. Furthermore this option enhances and simplifies the units commissioning, allowing also the interfacing towards other resources and devices. The keypad features aesthetic design, easy-to-use interface, smart LCD display. The regulation integrates numerous characteristics, depending on the units configuration and selected options: command of the dampers and of the free-cooling; regulation of the resources for heating, cooling as well as humidity and air quality; regulation and control of supply- and return fans. The diagnostics includes a complete alarm management, with the the “black-box” and alarm logging functions for enhanced analysis of the unit operation. Supervision can be easily developed via proprietary devices or the most common protocols as ModBus, Echelon LonWorks. Compatibility with the remote keyboard managing up to 10 units. Availability of an internal real time clock for operation scheduling (4-day profiles with 10 hour belts).

AHU

WIZARD

Air handling unit

0-115000 m3/hUnit DescriptionThe Wizard range of Air-Handling Units incorporate the entire design experience of Climaveneta in order to fully satisfy all market requirements in the various sectors of application. Tailored though massproduced industrial products, these high quality and reliable units guarantee total safety.Traditional sectors: residential building, airports, banks, shops, hotels, museums, theatres, cinemas, auditoriums, television studios, libraries and data processing centres. Specific sectors: pharmaceutical, food, hospital, electronic, maritime applications and temperature- or contamination-controlled production processes.

Page 333: Products Guide V01 - ParagonEfficient project management thanks to Climaveneta as unique project leader. Complete and specialized Organization Climaveneta qualifies itself for the

335

COOLINGHEATINGHUMIDIFICATIONRE-HEATINGCENTRIFUGALPLUG FANCONTROLLERLEAKAGE

WIZARD numerous executions available:

Page 334: Products Guide V01 - ParagonEfficient project management thanks to Climaveneta as unique project leader. Complete and specialized Organization Climaveneta qualifies itself for the

336

OTH

Page 335: Products Guide V01 - ParagonEfficient project management thanks to Climaveneta as unique project leader. Complete and specialized Organization Climaveneta qualifies itself for the

337

HERother

oth

er

Page 336: Products Guide V01 - ParagonEfficient project management thanks to Climaveneta as unique project leader. Complete and specialized Organization Climaveneta qualifies itself for the

338

Main accessoriesRubber anti-vibration mounting kit

Coil protection grid for models 0071÷0121

External main switch kit

HSW10 remote keyboard

FeaturesCoil protection grid for models 0011÷0061.

Structure and base in hot-dip galvanised steel with

epoxy powder paint finish.

External access to control with anti-tamper device.

Finned coils made with copper pipes and aluminium fins

with large exchange surface area, tested for leaks with

dried air at 30 bar.

User interface with display.

Phase sequence controller for models 0071÷0121

VersionsB base version

SL super-low noise version

other

BRAT-MC 0011÷0121

Condensing unit

4,9 - 32,9 kW

Unit DescriptionOutdoor split-system unit working with R410A refrigerant for connection with directexpansion coils or remote exchangers, with hermetic rotary scroll compressor andaxial-flow fans. External panels and basement and base in galvanised sheet steel withpaint finish.

Page 337: Products Guide V01 - ParagonEfficient project management thanks to Climaveneta as unique project leader. Complete and specialized Organization Climaveneta qualifies itself for the

339

Models 0041 0051 0061 0071 0091 0101 0121COOLING ONLY VERSION

Nominal Cooling capacity (1) kW 12,7 14,3 16,5 20,8 23,5 29,5 35,8

Total absorbed power (1) kW 4,3 4,7 5,3 6,9 7,9 8,4 11,4Absorbed current A 8,4 9,0 9,7 14,6 15,8 21,7 24,6Operational weight kg 125 145 155 245 250 320 325No. fans N. 2 2 2 1 1 2 2Airflow m3/h 6800 6800 6400 9800 9800 14000 14000Compressor type SCROLL SCROLL SCROLL SCROLL SCROLL SCROLL SCROLLRefrigerant R410A R410A R410A R410A R410A R410A R410ASound pressure level (2) dB(A) 54 54 54 61 61 63 63Sound power dB(A) 69 69 69 76 76 79 79Electrical power supply V-Ph~Hz 400V-3N~50Hz 400V-3N~50Hz 400V-3N~50Hz 400V-3N~50Hz 400V-3N~50Hz 400V-3N~50Hz 400V-3N~50HzDIMENSIONL mm 900 900 900 1450 1450 1450 1450H mm 1240 1240 1390 1200 1200 1700 1700P mm 370 370 420 550 550 550 550

BRAT-MC / BModels 0011 0021 0025 0031 0041 0021 0025 0031COOLING ONLY VERSIONNominal Cooling capacity (1) kW 5,6 6,6 7,5 9,6 12,7 6,1 7,5 9,3Total absorbed power (1) kW 1,9 2,2 2,5 3,4 4,1 2,0 2,4 3,2Absorbed current A 9,2 9,8 12,4 15,6 18,7 4,2 4,4 5,9Operational weight kg 80 85 100 105 125 85 100 105No. fans N. 1 1 1 1 2 1 1 1Airflow m3/h 2400 3500 3500 4200 6800 3500 3500 4200Compressor type SCROLL SCROLL SCROLL SCROLL SCROLL SCROLL SCROLL SCROLLRefrigerant R410A R410A R410A R410A R410A R410A R410A R410ASound pressure level (2) dB(A) 51 52 52 52 54 52 52 52Sound power dB(A) 65 66 66 66 69 66 66 66Electrical power supply V-Ph~Hz 230V~50Hz 230V~50Hz 230V~50Hz 230V~50Hz 230V~50Hz 400V-3N~50Hz 400V-3N~50Hz 400V-3N~50HzDIMENSIONL mm 900 900 900 900 900 900 900 900H mm 640 640 940 940 1240 640 940 940P mm 370 370 370 370 370 370 370 370

COOLING

r HFCR-410A

SCROLLAXIAL

Note:

1 Saturated intake temperature = 5°C; Condenser air (in) = 35°C..

2 Noise level measured at 1 m in open field conditions

Models 0071 0091 0101 0121COOLING ONLY VERSIONNominal Cooling capacity (1) kW 20,1 22,7 27,8 33,4Total absorbed power (1) kW 6,9 8,0 8,8 11,8Absorbed current A 12,4 13,6 18,6 21,5Operational weight kg 245 250 320 325No. fans N. 2 2 3 3Airflow m3/h 7000 7000 10500 10500Compressor type SCROLL SCROLL SCROLL SCROLLRefrigerant R410A R410A R410A R410ASound pressure level (2) dB(A) 59 59 60 60Sound power dB(A) 74 74 76 76Electrical power supply V-Ph~Hz 400V-3N~50Hz 400V-3N~50Hz 400V-3N~50Hz 400V-3N~50HzDIMENSIONL mm 1450 1450 1450 1450H mm 1200 1200 1700 1700P mm 550 550 550 550

Dimension

P

L

H

PL

HH

L

P

BRAT-MC / SL

Note:

1 Saturated intake temperature = 5°C; Condenser air (in) = 35°C.

2 Noise level measured at 1 m in open field conditions

Page 338: Products Guide V01 - ParagonEfficient project management thanks to Climaveneta as unique project leader. Complete and specialized Organization Climaveneta qualifies itself for the

340

FeaturesTOTAL VERSATILITY

Condensing units with scroll compressors in 4 versions, designed to satisfy all service system and application requirements.

CONTINUAL FAN SPEED CONTROL

The standard bi-compressor type HCAT units come fitted with continual fan speed control to guarantee more flexibility and adaptability

INTEGRAL SAFETY DEVICES

Standard units are all fitted with high and low pressure switches, high-pressure safety valve and magnetothermal circuit breakers on loads (bi-compressor unit only)

VersionsB base version

HT high efficiency, high outdoor temperature version

LN low noise version

SL super-low noise version

other

HCAT 0152÷0604

Condensing unit

38 - 160 kWUnit DescriptionOutdoor split-system unit for connection with direct expansion coils or remote exchangers, with hermetic rotary scroll compressors, axial-flow fans, compressor inlet and outlet valves with servicing plugs and liquid tap. External panels in Peraluman and base in galvanised sheet steel with paint finish. Refrigerant R407C, units with two and four-compressors, two refrigerant circuits.

Page 339: Products Guide V01 - ParagonEfficient project management thanks to Climaveneta as unique project leader. Complete and specialized Organization Climaveneta qualifies itself for the

341

Note:

1 Saturated intake temperature = 5°C; Condenser air (in) = 35°C.

2 Sound power on the basis of measurements made in compliance with ISO 9614 and Eurovent 8/1 for Eurovent certified units; in compliance with ISO 3744 for non-certified units.

3 Average sound pressure level, at 10m distance, unit in a free field on a reflective surface; non-binding value obtained from the sound power level.

HCAT / LNModels 0524 0604COOLINGCooling capacity (1) kW 134 152Total power input (1) kW 54,6 64,5COMPRESSORSNo. Compressors/No. Circuits N. 4/2 4/2 NOISE LEVELSSound power (2) dB(A) 86 86Sound pressure (3) dB(A) 54 54SIZEA mm 3110 3110B mm 2220 2220H mm 1700 1700Operating weight kg 1520 1600

Note:

1 Saturated intake temperature = 5°C; Condenser air (in) = 35°C.

2 Sound power on the basis of measurements made in compliance with ISO 9614 and Eurovent 8/1 for Eurovent certified units; in compliance with ISO 3744 for non-certified units.

3 Average sound pressure level, at 10m distance, unit in a free field on a reflective surface; non-binding value obtained from the sound power level.

HCAT / HTModels 0524 0604COOLINGCooling capacity (1) kW 146 170Total power input (1) kW 53,3 60,3COMPRESSORSNo. Compressors/No. Circuits N. 4/2 4/2 NOISE LEVELSSound power (2) dB(A) 94 94Sound pressure (3) dB(A) 62 62SIZEA mm 3110 3110B mm 2220 2220H mm 1700 2150Operating weight kg 1620 1700

Note:

1 Saturated intake temperature = 5°C; Condenser air (in) = 35°C.

2 Sound power on the basis of measurements made in compliance with ISO 9614 and Eurovent 8/1 for Eurovent certified units; in compliance with ISO 3744 for non-certified units.

3 Average sound pressure level, at 10m distance, unit in a free field on a reflective surface; non-binding value obtained from the sound power level.

HCAT / BModels 0152 0182 0202 0252 0302 0412 0512 0524 0604COOLINGCooling capacity (1) kW 37,7 47,0 54,7 66,5 79,8 112 139 141 160Total power input (1) kW 14,5 17,9 20,3 25,3 29,6 39,4 47,8 55,6 64,7COMPRESSORSNo. Compressors/No. Circuits N. 2/2 2/2 2/2 2/2 2/2 2/2 2/2 4/2 4/2 NOISE LEVELSSound power (2) dB(A) 78 79 79 81 81 85 85 94 94Sound pressure (3) dB(A) 46 47 47 49 49 53 53 62 62SIZEA mm 1695 2195 2195 2745 2745 3245 3245 3110 3110B mm 1120 1120 1120 1120 1120 1120 1120 2220 2220H mm 1420 1420 1420 1420 1420 1620 1620 1700 1700Operating weight kg 510 570 600 675 775 910 980 1520 1600

COOLING

r HFCR-407C

SCROLLAXIAL

Page 340: Products Guide V01 - ParagonEfficient project management thanks to Climaveneta as unique project leader. Complete and specialized Organization Climaveneta qualifies itself for the

342

Note:

1 Saturated intake temperature = 5°C; Condenser air (in) = 35°C.

2 Sound power on the basis of measurements made in compliance with ISO 9614 and Eurovent 8/1 for Eurovent certified units; in compliance with ISO 3744 for non-certified units.

3 Average sound pressure level, at 10m distance, unit in a free field on a reflective surface; non-binding value obtained from the sound power level.

HCAT / SLModels 0524 0604COOLINGCooling capacity (1) kW 132 152Total power input (1) kW 54,1 63,3COMPRESSORSNo. Compressors/No. Circuits N. 4/2 4/2 NOISE LEVELSSound power (2) dB(A) 79 79Sound pressure (3) dB(A) 47 47SIZEA mm 3110 3110B mm 2220 2220H mm 1700 2150Operating weight kg 1620 1700

A

B

H

Minimum clearance required0524-0604

Switchboard side mm 600Switchboard opposite side mm 600Condensation coil side mm 1000

Page 341: Products Guide V01 - ParagonEfficient project management thanks to Climaveneta as unique project leader. Complete and specialized Organization Climaveneta qualifies itself for the

343

Page 342: Products Guide V01 - ParagonEfficient project management thanks to Climaveneta as unique project leader. Complete and specialized Organization Climaveneta qualifies itself for the

344

FeaturesTOTAL VERSATILITY

Condensing units with scroll compressors in 4 versions, designed to satisfy all service system and application requirements.

SEMI-HERMETIC RECIPROCATING COMPRESSORS

The MCAT units are fitted with semi-hermetic reciprocating compressors with the possibility of extra capacity control step

INCORPORATED LIQUID RECEIVER

Standard units are all fitted with liquid receiver to ensure best operation of the condensing section

VersionsB base version

HT high efficiency, high outdoor temperature version

LN low noise version

SL super-low noise version

other

MCAT 0501÷1422

Condensing unit

119 - 325 kWUnit DescriptionOutdoor split-system unit for connection with direct expansion coils or remote exchangers. Semi-hermetic reciprocating compressors, axial-flow fans, liquid receiver, compressor inlet and outlet valves with servicing plugs and liquid tap. External panels in Peraluman and base in galvanised sheet steel with paint finish. Refrigerant R407C, units with 1 or 2 compressors, single or double circuits.

Page 343: Products Guide V01 - ParagonEfficient project management thanks to Climaveneta as unique project leader. Complete and specialized Organization Climaveneta qualifies itself for the

345

Note:

1 Saturated intake temperature = 5°C; Condenser air (in) = 35°C.

2 Sound power on the basis of measurements made in compliance with ISO 9614 and Eurovent 8/1 for Eurovent certified units; in compliance with ISO 3744 for non-certified units.

3 Average sound pressure level, at 10m distance, unit in a free field on a reflective surface; non-binding value obtained from the sound power level.

MCAT / LNModels 0501 0601 0502 0602 0702 0802 0822 1002 1202 1222 1422COOLINGCooling capacity (1) kW 115 135 111 129 154 179 195 226 271 285 312Total power input (1) kW 48,0 57,7 43,9 52,6 70,2 83,7 82,5 97,4 115COMPRESSORSNo. Compressors/No. Circuits N. 1/1 1/1 2/2 2/2 2/2 2/2 2/2 2/2 2/2 2/2 2/2NOISE LEVELSSound power (2) dB(A) * * * * * * * * *Sound pressure (3) dB(A) * * * * * * * * *SIZEA mm 3110 3110 3110 3110 3110 3110 3110 3110 4110B mm 2220 2220 2220 2220 2220 2220 2220 2220 2220H mm 1540 1540 1540 1540 1540 1540 1990 1990 1990Operating weight kg 1260 1310 1350 1420 1500 1610 1690 1870 2060

Note:

1 Saturated intake temperature = 5°C; Condenser air (in) = 35°C.

2 Sound power on the basis of measurements made in compliance with ISO 9614 and Eurovent 8/1 for Eurovent certified units; in compliance with ISO 3744 for non-certified units.

3 Average sound pressure level, at 10m distance, unit in a free field on a reflective surface; non-binding value obtained from the sound power level.

MCAT / HTModels 0501 0601 0502 0602 0702 0802 0822 1002 1202 1222 1422COOLINGCooling capacity (1) kW 127 149 122 143 174 211 223 256 305 321 351Total power input (1) kW 46,6 55,5 43,2 51,5 63,9 76,5 77,3 89,5 109COMPRESSORSNo. Compressors/No. Circuits N. 1/1 1/1 2/2 2/2 2/2 2/2 2/2 2/2 2/2 2/2 2/2NOISE LEVELSSound power (2) dB(A) * * * * * * * * *Sound pressure (3) dB(A) * * * * * * * * *SIZEA mm 3110 3110 3110 3110 3110 4110 4110 4110 5110B mm 2220 2220 2220 2220 2220 2220 2220 2220 2220H mm 1540 1540 1540 1540 1990 1990 1990 1990 1990Operating weight kg 1330 1390 1430 1500 1640 1880 1890 2100 2340

Note:

1 Saturated intake temperature = 5°C; Condenser air (in) = 35°C.

2 Sound power on the basis of measurements made in compliance with ISO 9614 and Eurovent 8/1 for Eurovent certified units; in compliance with ISO 3744 for non-certified units.

3 Average sound pressure level, at 10m distance, unit in a free field on a reflective surface; non-binding value obtained from the sound power level.

MCAT / BModels 0501 0601 0502 0602 0702 0802 0822 1002 1202 1222 1422COOLINGCooling capacity (1) kW 119 141 115 134 160 188 203 236 282 297 325 Total power input (1) kW 46,7 55,9 42,8 51,2 68,2 81,0 80,3 93,9 112 * * COMPRESSORSNo. Compressors/No. Circuits N. 1/1 1/1 2/2 2/2 2/2 2/2 2/2 2/2 2/2 2/2 2/2 NOISE LEVELSSound power (2) dB(A) * * * * * * * * * * * Sound pressure (3) dB(A) * * * * * * * * * * * SIZEA mm 3110 3110 3110 3110 3110 3110 3110 3110 4110 * * B mm 2220 2220 2220 2220 2220 2220 2220 2220 2220 * * H mm 1540 1540 1540 1540 1540 1540 1990 1990 1990 * * Operating weight kg 1260 1310 1350 1420 1500 1610 1690 1870 2060 * *

COOLING

r HFCR-407C

RECIPROCATINGAXIAL

Page 344: Products Guide V01 - ParagonEfficient project management thanks to Climaveneta as unique project leader. Complete and specialized Organization Climaveneta qualifies itself for the

346

Note:

1 Saturated intake temperature = 5°C; Condenser air (in) = 35°C.

2 Sound power on the basis of measurements made in compliance with ISO 9614 and Eurovent 8/1 for Eurovent certified units; in compliance with ISO 3744 for non-certified units.

3 Average sound pressure level, at 10m distance, unit in a free field on a reflective surface; non-binding value obtained from the sound power level.

MCAT / SLModels 0501 0601 0502 0602 0702 0802 0822 1002 1202 1222 1422COOLINGCooling capacity (1) kW 114 140 110 129 154 187 203 230 280 295 323Total power input (1) kW 49,0 56,7 44,9 53,3 67,9 80,9 79,9 95,4 113COMPRESSORSNo. Compressors/No. Circuits N. 1/1 1/1 2/2 2/2 2/2 2/2 2/2 2/2 2/2 2/2 2/2NOISE LEVELSSound power (2) dB(A) * * * * * * * * *Sound pressure (3) dB(A) * * * * * * * * *SIZEA mm 3110 3110 3110 3110 4110 4110 4110 4110 5110B mm 2220 2220 2220 2220 2220 2220 2220 2220 2220H mm 1540 1990 1540 1990 1990 1990 1990 1990 1990Operating weight kg 1370 1450 1460 1560 1780 1880 1890 2100 2340

H

BA

Minimum clearance required0501-1422

Switchboard side mm 1500Switchboard opposite side mm 1100Condensation coil side mm 2000

Page 345: Products Guide V01 - ParagonEfficient project management thanks to Climaveneta as unique project leader. Complete and specialized Organization Climaveneta qualifies itself for the

347

Page 346: Products Guide V01 - ParagonEfficient project management thanks to Climaveneta as unique project leader. Complete and specialized Organization Climaveneta qualifies itself for the

348

VersioniB base version

LN base version

SL super-low noise version

altro

NCE 118A÷428C

Remote condenser with axial fans

Remote condensers with axial-type fans for outdoor installation. Installation may be verticalwith a horizontal air outflow or, using special brackets, horizontal with an upward airoutflow. The very low noise, adjustable-speed fans are excellent for use for both industrialand commercial applications.

Unit Description

Page 347: Products Guide V01 - ParagonEfficient project management thanks to Climaveneta as unique project leader. Complete and specialized Organization Climaveneta qualifies itself for the

349

Note:

1 Outdoor air temperature = 30°C; delta temperature condenser side = 17°C

2 Sound power on the basis of measurements made in compliance with ISO 3744.

3 Without legs kit configuration ; horizontal air flow

NCE/BModels 118A 218A 318A 328A 118B 218B 318B 328BNOMINAL CHARACTERISTICSNominal capacity (1) kW 55 110 160 301 68 135 197 389Total power input (1) kW 11,7 23 38 77,6 15,8 30,1 42,9 87,6VENTILATION Air flow m3/h 21200 42400 63600 123600 19600 39000 58800 114000Sound power (2) dB(A) 81 84 86 89 81 84 86 89SIZEL (3) mm 1880 3230 3230 5930 1880 3230 4580 4580P (3) mm 800 800 800 800 800 800 800 800H (3) mm 1370 1370 1370 1370 1370 1370 1370 1370Weight kg 145 279 413 680 157 302 447 742

AXIAL

Models 418B 428B 118C 218C 318C 328C 418C 428CNOMINAL CHARACTERISTICSNominal capacity (1) kW 270 511 75 150 228 430 300 566Total power input (1) kW 60,2 110 18,3 33,9 48,1 97,8 67,9 123VENTILATION Air flow m3/h 78400 152000 18400 36800 55200 106200 73600 141600Sound power (2) dB(A) 86 90 81 84 86 89 86 90SIZEL (3) mm 4580 5930 1880 3230 4580 4580 5930 5930P (3) mm 800 800 800 800 800 800 800 800H (3) mm 1370 1370 1370 1370 1370 1370 1370 1370Weight kg 592 982 168 324 481 804 637 1065

Note:

1 Outdoor air temperature = 30°C; delta temperature condenser side = 17°C

2 Sound power on the basis of measurements made in compliance with ISO 3744.

3 Without legs kit configuration ; horizontal air flow

NCE/LNModels 118A 218A 318A 328A 118B 218B 318B 328BNOMINAL CHARACTERISTICSNominal capacity (1) kW 49 97 141 264 58 116 169 331Total power input (1) kW 12,2 23,9 39,5 81,2 16,7 31,6 44,8 50,5VENTILATION Air flow m3/h 17000 34000 51000 97800 15500 31000 46500 88800Sound power (2) dB(A) 75 78 80 83 75 78 80 83SIZEL (3) mm 1880 3230 4580 4580 1880 3230 4580 4580P (3) mm 800 800 800 800 800 800 800 800H (3) mm 1370 1370 1370 1370 1370 1370 1370 1370Weight kg 145 279 413 680 157 302 447 742

Models 418B 428B 118C 218C 318C 328C 418C 428CNOMINAL CHARACTERISTICSNominal capacity (1) kW 169 435 63 125 191 354 191 466Total power input (1) kW 49,7 115 19,5 35,9 50,9 105 57,6 130VENTILATION Air flow m3/h 46500 118400 14400 28800 43200 81000 43200 108000Sound power (2) dB(A) 80 84 75 78 80 83 80 84SIZEL (3) mm 4580 5930 1880 4580 4580 5930 5930 5930P (3) mm 800 800 800 800 800 800 800 800H (3) mm 1370 1370 1370 1370 1370 1370 1370 1370Weight kg 447 982 168 324 481 804 481 1065

r HFCR-410A

Page 348: Products Guide V01 - ParagonEfficient project management thanks to Climaveneta as unique project leader. Complete and specialized Organization Climaveneta qualifies itself for the

350

Note:

1 Outdoor air temperature = 30°C; delta temperature condenser side = 17°C

2 Sound power on the basis of measurements made in compliance with ISO 3744.

3 Without legs kit configuration ; horizontal air flow

NCE/SLModels 216A 218A 316A 318A 328A 418A 428A 216BNOMINAL CHARACTERISTICSNominal capacity (1) kW 45 79 67 115 215 158 295 49Total power input (1) kW 12,6 25,5 15,8 31,6 64,7 46 94,2 14,3VENTILATION Air flow m3/h 11600 24400 17400 36600 69600 48800 92800 10400Sound power (2) dB(A) 68 71 70 73 76 74 77 68SIZEL (3) mm 2630 3230 3770 4580 4580 5930 4580 2630P (3) mm 600 600 600 600 600 600 600 600H (3) mm 1230 1230 1230 1230 1230 1230 1230 1230Weight kg 150 279 221 413 680 547 900 166

Models 318B 328B 418B 428B 528B 218C 328C 418CNOMINAL CHARACTERISTICSNominal capacity (1) kW 133 259 182 340 430 95 273 190Total power input (1) kW 40,4 71 51,7 106 115 28,9 80,5 57,6VENTILATION Air flow m3/h 33000 62400 44000 83200 104000 20200 57600 40400Sound power (2) dB(A) 73 76 74 77 78 71 76 74SIZEL (3) mm 4580 4580 5930 4580 7280 3230 4580 5930P (3) mm 600 600 600 600 600 600 600 600H (3) mm 1230 1230 1230 1230 1230 1230 1230 1230Weight kg 447 742 592 982 1222 324 804 637

Page 349: Products Guide V01 - ParagonEfficient project management thanks to Climaveneta as unique project leader. Complete and specialized Organization Climaveneta qualifies itself for the

351

Page 350: Products Guide V01 - ParagonEfficient project management thanks to Climaveneta as unique project leader. Complete and specialized Organization Climaveneta qualifies itself for the

352

VersioniB base version

LN base version

SL super-low noise version

altro

FCE 218A÷828C

Remote condenser with axial fans

75,8 - 1088 kW

Remote condensers with axial-type fans for outdoor installation. Installation may be verticalwith a horizontal air outflow or, using special brackets, horizontal with an upward airoutflow. The very low noise, adjustable-speed fans are excellent for use for both industrialand commercial applications.

Unit Description

Page 351: Products Guide V01 - ParagonEfficient project management thanks to Climaveneta as unique project leader. Complete and specialized Organization Climaveneta qualifies itself for the

353

Note:

1 Outdoor air temperature = 30°C; delta temperature condenser side = 17°C

2 Sound power on the basis of measurements made in compliance with ISO 3744.

3 Without legs kit configuration ; horizontal air flow

FCE/BModels 218A 228A 218B 228B 318B 328B 428B 518B 528BNOMINAL CHARACTERISTICSNominal capacity (1) kW 78,8 150 98,1 182 123 237 386 259 894Total power input (1) kW 22,9 42,7 28 48,6 30,9 61,5 103 70,8 231VENTILATION Air flow m3/h 42400 82400 39200 76000 58800 114000 152000 98000 190000Sound power (2) dB(A) 84 87 84 87 86 89 90 88 91SIZEL (3) mm 3230 3230 3230 3230 4580 4580 5930 7280 7280P (3) mm 800 800 800 800 800 800 800 800 800H (3) mm 1370 2390 1370 2390 1370 2390 2390 1370 2390Weight kg 279 462 302 502 447 742 982 737 1222

AXIAL

r HFCR-134a

Models 628B 828B 228C 328C 418C 428C 518C 528C 628CNOMINAL CHARACTERISTICSNominal capacity (1) kW 534 755 203 329 219 440 293 506 572Total power input (1) kW 137 204 56,2 87 59,4 121 78,4 130 140VENTILATION Air flow m3/h 228000 236800 70800 106200 73600 141600 92000 177000 212400Sound power (2) dB(A) 91 94 87 89 87 90 88 91 92SIZEL (3) mm 8630 11330 3230 4580 5930 5930 7280 7280 8630P (3) mm 800 800 800 800 800 800 800 800 800H (3) mm 2390 2390 2390 2390 1370 2390 1370 2390 2390Weight kg 1461 1942 543 804 637 1065 794 1325 1585

Note:

1 Outdoor air temperature = 30°C; delta temperature condenser side = 17°C

2 Sound power on the basis of measurements made in compliance with ISO 3744.

3 Without legs kit configuration ; horizontal air flow

FCE/LNModels 218A 228A 328A 218B 228B 318B 328B 428B 518B 528BNOMINAL CHARACTERISTICSNominal capacity (1) kW 77,1 147 220 95,3 177 120 265 374 252 436Total power input (1) kW 23,6 44,2 69,3 29,2 50,6 32 78,5 107 74,3 121VENTILATION Air flow m3/h 34000 65200 97800 31000 59200 46500 88800 118400 77500 148000Sound power (2) dB(A) 78 81 83 78 81 80 83 84 82 85SIZEL (3) mm 3230 3230 4580 3230 3230 4580 4580 5930 7280 7280P (3) mm 800 800 800 800 800 800 800 800 800 800H (3) mm 1370 2390 2390 1370 2390 1370 2390 2390 1370 2390Weight kg 279 462 680 302 502 447 742 982 737 1222

Models 628B 828B 228C 328C 418C 428C 518C 528C 628CNOMINAL CHARACTERISTICSNominal capacity (1) kW 521 732 197 318 214 423 283 489 556Total power input (1) kW 143 213 59 92,3 62,9 129 82,5 137 147VENTILATION Air flow m3/h 177600 236800 54000 81000 57600 108000 72000 135000 162000Sound power (2) dB(A) 86 88 81 83 81 84 82 85 86SIZEL (3) mm 8630 11330 3230 4580 5930 5930 7280 7280 8630P (3) mm 800 800 800 800 800 800 800 800 800H (3) mm 2390 2390 2390 2390 1370 2390 1370 2390 2390Weight kg 1461 1942 543 804 637 1065 794 1325 1585

Page 352: Products Guide V01 - ParagonEfficient project management thanks to Climaveneta as unique project leader. Complete and specialized Organization Climaveneta qualifies itself for the

354

Note:

1 Outdoor air temperature = 30°C; delta temperature condenser side = 17°C

2 Sound power on the basis of measurements made in compliance with ISO 3744.

3 Without legs kit configuration ; horizontal air flow

FCE/SLModels 318A 416A 418A 428A 318B 328B 418B 428B 518B 528B 628BNOMINAL CHARACTERISTICSNominal capacity (1) kW 94,8 75,8 131 252 114 215 148 287 196 274 433Total power input (1) kW 29,4 24,2 39,4 74,3 34,7 62,5 43,6 80,7 59,2 107 124VENTILATION Air flow m3/h 36600 23200 48800 92800 33000 82200 44000 83200 55000 104000 124800Sound power (2) dB(A) 73 71 74 77 73 76 74 77 75 78 79SIZEL (3) mm 4580 4910 5930 5930 4580 4580 5930 5930 7280 7280 8630P (3) mm 800 600 800 800 800 800 800 800 800 800 800H (3) mm 1370 1230 1370 2390 1370 2390 1370 2390 1370 2390 2390Weight kg 413 292 547 900 447 742 592 982 737 1222 1461

Models 728B 828B 228C 328C 418C 428C 528C 628C 728C 828CNOMINAL CHARACTERISTICSNominal capacity (1) kW 511 575 156 225 173 321 396 481 544 647Total power input (1) kW 147 162 48 66,9 52,2 91 119 140 152 183VENTILATION Air flow m3/h 145600 1664000 38400 76200 40400 76800 96000 115200 134400 153600Sound power (2) dB(A) 79 80 74 76 74 77 78 79 79 80SIZEL (3) mm 9980 11330 3230 4580 5930 5930 7280 8630 9980 11330P (3) mm 800 800 800 800 800 800 800 800 800 800H (3) mm 2390 2390 2390 2390 1370 2390 2390 2390 2390 2390Weight kg 1702 1942 543 804 637 1065 1325 1585 1845 2106

Page 353: Products Guide V01 - ParagonEfficient project management thanks to Climaveneta as unique project leader. Complete and specialized Organization Climaveneta qualifies itself for the

355

Page 354: Products Guide V01 - ParagonEfficient project management thanks to Climaveneta as unique project leader. Complete and specialized Organization Climaveneta qualifies itself for the
Page 355: Products Guide V01 - ParagonEfficient project management thanks to Climaveneta as unique project leader. Complete and specialized Organization Climaveneta qualifies itself for the
Page 356: Products Guide V01 - ParagonEfficient project management thanks to Climaveneta as unique project leader. Complete and specialized Organization Climaveneta qualifies itself for the