Psifluidpower.ca Sites Psifluidpower.ca Files Media Product 10-6

Embed Size (px)

Citation preview

  • 8/13/2019 Psifluidpower.ca Sites Psifluidpower.ca Files Media Product 10-6

    1/16

    SC Hydraulic Engineering 1130 Columbia St. Brea, CA. 92821 (714) 257-4800

    1. Available Air pressure and Flow RateFor optimum performance, the maximum

    recommended air pressure for continuous duty is

    100 psig for all pumps and power units. Air -

    drive pressure up to 150 psig may be used

    intermittently.

    2. Required Hydraulic Output pressure and

    Flow RateWe recommend that SC pumps be selected to

    deliver the required hydraulic flow rate and

    output pressure with 70 psig of air-drive

    pressure. This will provide a safety factor if air-drive pressure decreases for any reason. For

    hydraulic pressure, see "Approximate Air to

    Hydraulic Pressure Ratios -- Static Conditions".

    For hydraulic flow, see "Hydraulic Pump

    Approximate Rate of Discharge".

    3. Type of Fluid Being PumpedThe type of fluid being pumped is an important

    consideration in the selection of a pump. The

    materials of the hydraulic assembly and

    compounds of the hydraulic seals are determined

    by the specific fluid. Standard SC pumps are

    available for oil, water and most benign fluids.The standard hydraulic seal compound is Nitrile

    (Buna-N) with Tetrafluoroethylene (Teflon back

    up rings.) Pumps and power units can be

    purchased for other types of fluids. Consult the

    factory for recommended seal combinations.

    4. Acceptable Size and WeightFor some applications, the unit's physical size

    and weight may be an important consideration.

    How to order SC Air Operated Liquid Pumps

    *Note: hydraulic seal performance and life

    will be effected to some degree with non-

    lubricating fluids, such as water, than with

    lubrication type fluids.

    *Notice: Some Charts and Diagrams may

    need to be enlarged to see fine detail.

  • 8/13/2019 Psifluidpower.ca Sites Psifluidpower.ca Files Media Product 10-6

    2/16

    SC Hydraulic Engineering 1130 Columbia St. Brea, CA. 92821 (714) 257-4800

    -

    1 2 3 4 5 6 Table Reference

    Example #1 Example #21) Hydraulic Pump series 10-5 1) Hydraulic Pump series 10-6

    2) Seal Compound Air drive V 2) Seal Compound Air drive 0

    3) Seal Compound Hydraulic V 3) Seal Compound Hydraulic 0

    4) Modifications D 4) Modifications E

    5) Hydraulic section Material W 5) Hydraulic section Material S

    6) Model Number 060 6) Model Number 020

    10-5 V V D W 060 10-6 0 0 E S 02010-5 Series Pump with Viton Air seal and Viton 10-6 Series Pump with Standard Air and Hydraulic

    Hydraulic seal with Heavy Duty bottom Inlet Mod. seals with bottom inlet "A" Mod. in Stainless Steel

    in Aluminum Bronze &Stainless Steel construction construction with a Pressure Ratio of 35:1.

    with a Pressure Ratio of 105:1. Max Output 10,500 psi. Max Output 3,500 psi.

    10 - 4 10 - 4 Series air operated liquid pump O Standard Pump

    10 - 5 10 - 5 Series air operated liquid pump A "A" Modification (See Mod Chart)

    10 - 6 10 - 6 Series air operated liquid pump B Bottom Inlet

    D Bottom Inlet Heavy Duty (notes 1,3)

    E Bottom Inlet "A" Modification (1)

    G Isolator Heavy Duty (1,3)

    O Buna - N (Standard) H Heavy Duty (1)

    V Viton J Bottom Inlet "K" Modification (1)

    K "K" Modification (See Mod Chart) (1)

    M Bottom Inlet "A" and "K" Modification (1)

    N Isolator "A" Modification (1)O Buna - N (Standard) P Isolator "K" Modification (1)

    E EPR Q Isolator "A" and "K" Modification (1)

    V Viton R Isolator (1)

    * Special compounds contact factory S Heavy Duty "K" Modification (1,3)

    U Heavy Duty Bottom Inlet "K" Modification

    (1,3)

    V Heavy Duty Isolator "K" Modification (1,3)

    C Cadmium plated Carbon Steel &

    Stainless Steel (2)

    S All Stainless Steel

    W Aluminum Bronze & Stainless Steel

    Refer to our Pressure Ratio Chart for Model # Selection.

    "Max Pressure calculation "

    Inlet Air Drive psi times Ratio number equals max Hydraulic Outlet psi.

    100 psi * 35 = 3,500 psi max.

    SC Air Operated Liquid Pumps

    Model Selection table:

    Table 1. Pump Series Designation Table 4. Modifications

    Table 2. Seal Compound Air Drive

    Table 3. Seal Compound Hydraulic

    Table 5. Construction Material

    Hydraulic Section

    Table 6. Model Description and Ratio

    Notes:

    1) Not available for 10-4series pump.

    2) For oil service only, withorders of 25 units or

    more.

    3) "A" Modificationstandard on all "H"

    models.

  • 8/13/2019 Psifluidpower.ca Sites Psifluidpower.ca Files Media Product 10-6

    3/16

    SC Hydraulic Engineering 1130 Columbia St. Brea, CA. 92821 (714) 257-4800

    OLD REF. OLD REF OLD REF

    0.25 003 5 0.24 003 5 .35QR 003 5

    0.5 005 10 0.5 005 10 .5QR 005 10

    1 010 15 0.65 007 12 1 010 20

    1.5 015 30 1 010 20 1.5 015 25

    2 020 35 1.5 015 25 2 020 35

    3 030 55 1.75 018 30 3 030 55

    5 050 100 2 020 35 5 050 95

    8 080 140 3 030 55 8 080 145

    12.5 125 220 4 040 70 10 100 180

    4.5 045 85 15 C151 240

    6 060 105 20 C201 330

    8 080 140 30 301 460

    10 100 195 40 402 740

    16 160 280

    25 250 440

    35 350 555

    PR ESSU RE RATIO CHART

    10-4 SER IES 10-5 SER IES 10-6 SER IES

    Part N um ber PRESSURE

    RATIO

    Part N um ber PRESSURE

    RATIO

    Part N um ber PRESSURE

    RATIO

    When operating form 0 to rated hydraulic pressure, air consumption will be approximately 56 scfm of

    free air at 100-psi input. At lower air pressures and higher hydraulic pressures air consumption will be

    reduced proportionately to flow rates indicated.

    * 10-6 Series

    When operating form 0 to rated hydraulic pressure, air consumption will be approximately 28 scfm of

    free air at 100-psi input. At lower air pressures and higher hydraulic press ures air consumpt ion will be

    reduced proportionately to flow rates indicated.

    * 10-5 Series

    When operating from 0 to rated hydraulic pressure, air consumption will be approximately 14 scfm of

    free air to 100-psi input. At lower air pressures and higher hydraulic pressures air consumption will

    be reduced proportionately to flow rates indicated.

    * 10-4 Series

    Model Number Model Number Model Number

  • 8/13/2019 Psifluidpower.ca Sites Psifluidpower.ca Files Media Product 10-6

    4/16

    SC Hydraulic Engineering 1130 Columbia St. Brea, CA. 92821 (714) 257-4800

    * Not available in 10-4 Series

    Special and Modified Pumps

    ."A" Modification *

    The "A" modification utilizes dual seals in the hydraulic assembly with a bleed port

    between the seals to atmosphere, providing a visual indication of hydraulic seal leakage.

    Used where contamination of the air motor from the hydraulic fluid being pumped is

    objectionable.

    ."K" Modification *

    The "K" modification utilizes a special air piston in the air motor assembly which decreases

    the stroke of the pump, thus minimizing the internal forces and increasing sir motor service

    life. Used in applications exhibiting rapid pressure losses, such as burst pressure testing.

    ."B" Models *

    The "B" models have a bottom inlet connection for convenient tank top installation.

    10-4, 10-5, and 10-6 Series

    A combination of any of the modifications shown can be supplied upon request.

    Write or call the factory for information and prices.

    ."H" Models *

    The "H" models utilize special packing in the hydraulic assembly for maximum performance

    where hydraulic fluid media is contaminated with foreign matter, providing for a much greater

    life expectancy from the hydraulic seals than with standard "O" ring seals. "A" modification

    is standard on all "H" models.

    ."R" Models *

    The "R" models are furnished with an isolator attachment which prevents the hydraulic piston

    from retracting into the air motor during operation, providing for 100% non contamination of the

    hydraulic assembly from the air motor. The isolator attachment also acts as a heat barrier.

  • 8/13/2019 Psifluidpower.ca Sites Psifluidpower.ca Files Media Product 10-6

    5/16

    SC Hydraulic Engineering 1130 Columbia St. Brea, CA. 92821 (714) 257-4800

    LEGEND

    1. Filter, regulator, lubricator assembly 7. Air exhaust muffler 13. Fluid bleed valve2. Air shut off valve 8. Pressure unloading valve, air operated 14. Hydraulic press3. Hydraulic filter 9. Hydraulic pressure gauge 15. Check valve4. Manual 4 way air valve 10. Test chamber 16. Hydraulic reservoir5. Air sequence valve 11. Test object6. SC air operated hydraulic pump 12. Pressure relief valve

    TYPICAL CIRCUIT FOR INSTALLATION

    TYPICAL CIRCUIT FOR STATIC PRESSURE TEST

    TYPICAL CIRCUIT FOR OPERATION OF HYDRAULIC PRESS

  • 8/13/2019 Psifluidpower.ca Sites Psifluidpower.ca Files Media Product 10-6

    6/16

    SC Hydraulic Engineering 1130 Columbia St. Brea, CA. 92821 (714) 257-4800

    10-6 SeriesAir Operated Hydraulic Pump Specification and Installation Data

    10-6 Series Mounting Dimensions (Inches)

    10-6 SeriesModel No.

    -003

    -005

    -010 thru -020

    -030 thru -100

    -151 thru -301

    -402

    L

    19 5/8

    18 5/8

    17 1/16

    15 3/4

    16

    16 1/4

    A

    47/8

    43/4

    3

    3

    21/2

    B

    2 3/8

    4 3/8

    4

    3 3/8

    25/16

    25/16

    CNPTF

    1

    1

    1

    3/8

    3/8

    DNPTF

    1

    1

    3/8

    E

    1 1/2

    1 3/8

    1

    7/8

    7/8

    1 1/8

    F

    --

    2 3/8

    1 3/4

    1 3/4

    1 3/4

    2 3/8

    G

    4

    3

    2

    2

    2

    3

    Mounting may be in any position, Vertical preferr

    When mounting is in an inverted position, a drcock should be provided to drain off any liquid t

    might accumulate in the pilot valve air chamber.

  • 8/13/2019 Psifluidpower.ca Sites Psifluidpower.ca Files Media Product 10-6

    7/16

    SC Hydraulic Engineering 1130 Columbia St. Brea, CA. 92821 (714) 257-4800

    10-6 Series Approximate Air to Hydraulic Pressure Ratios

    Static Conditions

    10-6SeriesModel

    10

    50

    85

    165

    180

    250

    450

    750

    1,100

    1,500

    1,910

    3,000

    4,000

    6000

    20

    100

    185

    425

    450

    625

    1,050

    1,750

    2,600

    3,200

    4,400

    6,000

    8,800

    13000

    30

    150

    285

    650

    725

    1,025

    1,700

    2,800

    4,200

    5,200

    6,900

    9,500

    13,700

    21000

    40

    200

    390

    875

    1,000

    1,400

    2,275

    3,700

    5,550

    7,100

    9,100

    12,600

    18,000

    27000

    50

    250

    490

    1,075

    1,300

    1,800

    2,900

    4,750

    7,100

    9,000

    11,600

    16,000

    22,500

    34000

    60

    300

    590

    1,300

    1,550

    2,150

    3,500

    5,900

    8,500

    10,800

    14,000

    19,100

    27,000

    40500

    70

    350

    690

    1,550

    1,850

    2,500

    4,100

    6,875

    10,000

    12,500

    16,400

    22,300

    31,500

    46000

    80

    400

    795

    1,750

    2,125

    2,850

    4,650

    7,700

    11,500

    14,500

    18,800

    25,600

    36,500

    52000

    90

    450

    900

    1,950

    2,400

    3,250

    5,200

    8,750

    12,950

    16,300

    21,300

    29,000

    41,400

    59000

    100

    500

    1,000

    2,150

    2,700

    3,600

    6,000

    9,700

    14,400

    18,000

    23,700

    32,300

    45,800

    65000

    -003

    -005

    -010

    -015

    -020

    -030

    -050

    -080

    -100

    -151

    -201

    -301

    -402

    AirPressure PSI

  • 8/13/2019 Psifluidpower.ca Sites Psifluidpower.ca Files Media Product 10-6

    8/16

    SC Hydraulic Engineering 1130 Columbia St. Brea, CA. 92821 (714) 257-4800

    10-6 Ser ies

    Model No .

    -003

    -005

    -010

    -015

    -020

    -030

    -050

    -080

    -100

    -151

    -201

    -301

    -402

    Hyd raulic PistonDiameter(Inches)

    3.000

    2.125

    1.4375

    1.315

    1.125

    .875

    .6875

    .5625

    .500

    .4375

    .375

    .3125

    .250

    HydraulicPiston Area

    (Square Inches)

    7.07

    3.56

    1.62

    1.35

    .994

    .601

    .371

    .249

    .196

    .150

    .110

    .077

    .049

    Volu me perStroke

    (Cubic Inches)

    17.7

    8.90

    4.05

    3.38

    2.49

    1.50

    .928

    .623

    .490

    .375

    .275

    .193

    .123

    10-6 Series Measurements

  • 8/13/2019 Psifluidpower.ca Sites Psifluidpower.ca Files Media Product 10-6

    9/16

    SC Hydraulic Engineering 1130 Columbia St. Brea, CA. 92821 (714) 257-4800

    Liquid Pump Cut-a-way

  • 8/13/2019 Psifluidpower.ca Sites Psifluidpower.ca Files Media Product 10-6

    10/16

    SC Hydraulic Engineering 1130 Columbia St. Brea, CA. 92821 (714) 257-4800

    0 5 0 10 0 15 0 20 0 25 0 30 0 35 0 40 0 45 0 50 0

    0

    50 0

    1 0 0 0

    1 5 0 0

    2 0 0 0

    2 5 0 0

    3 0 0 0

    3 5 0 0

    4 0 0 0

    POutput

    (lb/in2)

    QOutput

    (in

    3/m

    in.)

    0 5 1 0 1 5 2 0 2 5 3 0

    0

    1 0

    2 0

    3 0

    4 0

    5 0

    6 0

    60 psi

    (4.14 Bar)

    80 psi

    (5.12 Bar)

    100 psi

    (6.89 Bar)

    POutput

    (Bar)

    QOutput(Liter/min.)

    -00 3

    5:1

    0 20 0 40 0 60 0 80 0 1 00 0

    0

    25 0

    50 0

    75 0

    1 0 0 0

    1 2 5 0

    1 5 0 0

    1 7 5 0

    2 0 0 0

    60 psi

    (4.14 Bar)

    80 psi

    (5.12 Bar)

    1 00 psi

    (6.89 Bar)

    QOutput(Liter/min.)Q

    Output(

    in3/min.)

    POutput

    (lb/in2)

    POutput

    (Bar)

    0 1 0 2 0 3 0 4 0 5 0 6 0 7 0

    0

    5

    1 0

    1 5

    2 0

    2 5

    3 0

    -005

    10:1

    Air Operated Hydraulic Pump

    10-6 Series Approximate Rate of Discharge

  • 8/13/2019 Psifluidpower.ca Sites Psifluidpower.ca Files Media Product 10-6

    11/16

    SC Hydraulic Engineering 1130 Columbia St. Brea, CA. 92821 (714) 257-4800

    Approximate Rate of Discharge

    10-6 SeriesAir Operated Hydraulic Pump

    0 5 0 0 10 0 0 15 0 0 20 0 0 25 0 0 30 0 0

    0

    1 0 0

    2 0 0

    3 0 0

    4 0 0

    5 0 0

    6 0 0

    7 0 0

    8 0 0

    9 0 0

    1 00 psi

    (6.89 BA R)

    80 psi

    (5.12 BA R)

    60 psi

    (4.14 BA R)

    Q

    Output(

    in3/min.)

    POutput

    (lb/in2)

    0 2 0 4 0 6 0 8 0 1 0 0 1 2 0 1 4 0 1 6 0 1 8 0 2 0 0

    0

    2

    4

    6

    8

    1 0

    1 2

    1 4

    QOutput(Liter/m

    in.)

    POutput

    (Bar)

    -015

    25:1

    0 2 0 0 4 0 0 6 0 0 8 0 0 1 0 00 12 0 0 14 0 0 16 0 0 18 0 0 20 0 0 22 0 0 24 0 0

    0

    1 00

    2 00

    3 00

    4 00

    5 00

    6 00

    7 00

    8 00

    9 00

    1000

    1 00 p si

    (6.89 Bar)

    80 psi

    (5.12 Bar)

    60 psi

    (4.14 Bar)

    QOutput(

    in3/min.)

    POutput

    (lb/in2)

    0 20 40 60 80 1 00 1 20 1 40 1 60

    0

    2

    4

    6

    8

    10

    12

    14

    16

    QOutput(Liter/min.)

    POutput

    (Bar)

    -010

    20:1

  • 8/13/2019 Psifluidpower.ca Sites Psifluidpower.ca Files Media Product 10-6

    12/16

    SC Hydraulic Engineering 1130 Columbia St. Brea, CA. 92821 (714) 257-4800

    Approximate Rate of Discharge

    10-6 SeriesAir Operated Hydraulic Pump

    0 50 0 1 00 0 1 50 0 2 00 0 2 50 0 3 00 0 3 50 0 4 00 0

    0

    5 0

    10 0

    15 0

    20 0

    25 0

    30 0

    35 0

    40 0

    45 0

    50 0

    55 0

    60 0

    65 0

    100 psi

    (6.89 Bar)

    80 psi(5.12 Bar)60 psi

    (4.14 Bar)

    QOutput(

    in3/min.)

    POutput

    (lb/in2)

    0 2 5 5 0 7 5 10 0 12 5 15 0 17 5 20 0 22 5 25 0 27 5

    0

    1

    2

    3

    4

    5

    6

    7

    8

    9

    1 0

    QOutput(Liter/min.)

    POutput

    (Bar)

    -020

    35:1

    0 10 0 0 20 0 0 30 0 0 40 0 0 50 0 0 60 0 0

    0

    5 0

    1 0 0

    1 5 0

    2 0 0

    2 5 0

    3 0 0

    3 5 0

    4 0 0

    1 00 psi

    (6.89 Bar)80 psi

    (5.12 Bar)

    60 psi

    (4.14 Bar)

    Q

    Output(

    in3/m

    in.)

    POutput

    (lb/in2)

    0 5 0 1 0 0 1 5 0 2 0 0 2 5 0 3 0 0 3 5 0 4 0 0

    0

    1

    2

    3

    4

    5

    6

    QOutput(Liter/mi

    n.)

    POutput

    (Bar)

    -030

    55:1

  • 8/13/2019 Psifluidpower.ca Sites Psifluidpower.ca Files Media Product 10-6

    13/16

    SC Hydraulic Engineering 1130 Columbia St. Brea, CA. 92821 (714) 257-4800

    Approximate Rate of Discharge

    10-6 SeriesAir Operated Hydraulic Pump

    0 2500 5000 7500 100 00 1 2500 1 50000

    20

    40

    60

    80

    1 00

    1 20

    1 40

    1 60

    1 80

    2 00

    100 psi

    (6.8 9 Bar)

    80 ps i

    (5.1 2 Ba r)60 ps i

    (4.1 4 Ba r)

    QOutpu

    t(in

    3/min.)

    POutput

    (lb/in2)

    0 1 00 2 00 300 4 00 5 00 600 7 00 8 00 900 1000

    0 .0

    0 .5

    1 .0

    1 .5

    2 .0

    2 .5

    3 .0

    QOutput(Lit

    er/min.)

    POutput

    (Bar)

    -080

    14 5:1

    0 10 00 20 00 30 00 40 00 50 00 60 00 70 00 80 00 90 00 1 00 00

    0

    50

    1 00

    1 50

    2 00

    2 50

    100 psi

    (6.89 Bar)

    80 psi

    (5.12 Bar)

    60 psi

    (4.14 Bar)

    QOutput(

    in3/m

    in.)

    POutput

    (lb/in2)

    0 1 00 2 00 3 00 4 00 5 00 6 00

    0.0

    0.5

    1.0

    1.5

    2.0

    2.5

    3.0

    3.5

    4.0

    QOutput(Liter/min.)

    POutput

    (Bar)

    -050

    95:1

  • 8/13/2019 Psifluidpower.ca Sites Psifluidpower.ca Files Media Product 10-6

    14/16

    SC Hydraulic Engineering 1130 Columbia St. Brea, CA. 92821 (714) 257-4800

    Approximate Rate of Discharge

    10-6 SeriesAir Operated Hydraulic Pump

    0 25 00 50 00 75 00 1 00 00 1 25 00 1 50 00 1 75 00 2 00 00 2 25 00 2 50 000

    10

    20

    30

    40

    50

    60

    70

    80

    90

    100

    100 p si

    (6 .8 9 Bar)

    80 p si(5 .1 2 Bar)

    6 0 p si

    (4 .1 4 Bar)

    QOutput(

    in3/min.)

    POutput

    (lb/in2)

    0 200 400 600 800 1000 1200 1400 1600

    0.0

    0 .2

    0 .4

    0 .6

    0 .8

    1 .0

    1 .2

    1 .4

    1 .6

    QOutput(Liter/min.)

    POutput

    (Bar)

    -150

    24 0:1

    0 25 00 50 00 75 00 1 00 00 1 25 00 1 50 00 1 75 00 2 00 00

    0

    25

    50

    75

    1 00

    1 25

    1 50

    100 psi

    (6.89 B ar)

    8 0 psi(5.12 B ar)

    6 0 p si

    (4.14 B ar)

    QOutput(

    in3/m

    in.)

    POutput

    (lb/in2)

    0 1 50 3 00 4 50 6 00 7 50 9 00 10 50 1 2 00 13 50

    0 .0

    0 .3

    0 .6

    0 .9

    1 .2

    1 .5

    1 .8

    2 .1

    2 .4

    QOutput(Liter/min

    .)

    POutput

    (Bar)

    -100

    18 0:1

  • 8/13/2019 Psifluidpower.ca Sites Psifluidpower.ca Files Media Product 10-6

    15/16

    SC Hydraulic Engineering 1130 Columbia St. Brea, CA. 92821 (714) 257-4800

    0 5 00 0 1 0 00 0 1 5 00 0 2 0 00 0 2 5 00 0 3 0 00 0 3 5 00 0 4 0 00 0 4 5 00 0 5 0 00 0

    0

    5

    1 0

    1 5

    2 0

    2 5

    3 0

    3 5

    4 0

    4 5

    5 0

    100 psi

    (6.89 Bar)

    80 psi

    (5.12 Bar)

    60 psi

    (4.14 Bar)

    Q

    Output(

    in3/min.)

    POutput

    (lb/in2)

    0 30 0 60 0 90 0 1 20 0 1 50 0 1 80 0 2 10 0 2 40 0 2 70 0 3 00 0 3 30 0

    0. 0

    0. 1

    0. 2

    0. 3

    0. 4

    0. 5

    0. 6

    0. 7

    0. 8

    QOutput(m

    3/min.)

    POutput

    (Bar)

    -301*

    46 0:1

    0 5 000 10 000 15 000 20 000 25 000 30 000 35 000 40 000

    0

    10

    20

    30

    40

    50

    60

    70

    80

    100 p si

    (6.89 Bar)

    80 p si

    (5.12 Bar)

    6 0 psi

    (4.14 Bar)

    QOutput(

    in3/min.)

    POutput

    (lb/in2)

    0 2 50 5 00 7 50 1 000 1 250 1 500 17 50 2 000 22 50 25 00 2 750

    0 .0

    0 .2

    0 .4

    0 .6

    0 .8

    1 .0

    1 .2

    QOutput(Liter/min

    .)

    POutput

    (Bar)

    -201*

    33 0:1

    Air Operated Hydraulic Pump

    10-6 Series Approximate Rate of Discharge

  • 8/13/2019 Psifluidpower.ca Sites Psifluidpower.ca Files Media Product 10-6

    16/16

    SC Hydraulic Engineering 1130 Columbia St. Brea, CA. 92821 (714) 257-4800

    * Recommended fo r continuous duty at pressures to 30,000 psi. Intermittent duty above 30,000 psi.

    If 10-6 Series Hydrsaulic Pump Approximate Rate of D ischarge (CIPM) exceeds you r requirements, refer to 10-5 Series Hydraul ic

    Pump Approximate Rate of Discharge (CIPM) charts.

    0 1 00 00 2 00 00 3 00 00 4 00 00 5 00 00 6 00 00 7 00 00

    0

    5

    10

    15

    20

    25

    30

    100 p si

    (6.89 Bar)

    8 0 p si

    (5.12 Bar)6 0 p si

    (4.14 Bar)

    QOutput(

    in3/min.)

    POutput

    (lb/in2)

    0 5 00 10 00 15 00 20 00 25 00 30 00 35 00 40 00 45 00

    0.0

    0.1

    0.2

    0.3

    0.4

    0.5

    QOutput(Liter/min.)

    POutput

    (Bar)

    -402*

    74 0:1

    Air Operated Hydraulic Pump

    10-6 Series Approximate Rate of Discharge