QTRAP 6500+ and SelexION+- Improving the Sensitivity, Speed and Selectivity in Food, Clinical Research and Pharmaceutical Applications Jianru Stahl-Zeng. Ph D Darmstadt, Germany

QTRAP 6500+ and SelexION+- Improving the Sensitivity, Speed …per-form.hu/wp-content/uploads/2015/08/QTRAP6500-and-SelexION... · Detection of Somatostatin with and without SelexION+

  • Upload
    others

  • View
    1

  • Download
    0

Embed Size (px)

Citation preview

Page 1: QTRAP 6500+ and SelexION+- Improving the Sensitivity, Speed …per-form.hu/wp-content/uploads/2015/08/QTRAP6500-and-SelexION... · Detection of Somatostatin with and without SelexION+

QTRAP 6500+ and SelexION+- Improving the Sensitivity, Speed and Selectivity in Food, Clinical Research and Pharmaceutical Applications

Jianru Stahl-Zeng. Ph D

Darmstadt, Germany

Page 2: QTRAP 6500+ and SelexION+- Improving the Sensitivity, Speed …per-form.hu/wp-content/uploads/2015/08/QTRAP6500-and-SelexION... · Detection of Somatostatin with and without SelexION+

2 © 2015 AB Sciex

Agenda

• 6500+ LC/MS System Hardware Improvements

• 6500+ LC/MS System Features and Application Benefits

• Application Data Examples

Page 3: QTRAP 6500+ and SelexION+- Improving the Sensitivity, Speed …per-form.hu/wp-content/uploads/2015/08/QTRAP6500-and-SelexION... · Detection of Somatostatin with and without SelexION+

3 © 2015 AB Sciex

The New SCIEX 6500+ Series with HED+ Detector Technology

New -Sensitivity boost with “new HED+

detector technology” in negative mode

New -Enhanced SelexION performance with

“new jet injector DMS cell” without

compromising resolution

New -Fast polarity switching speed

(5 msec)

New -Audible noise reduction

Industry proven performance: IonDrive™ Turbo V™ ion source and QJet® ion guide

Page 4: QTRAP 6500+ and SelexION+- Improving the Sensitivity, Speed …per-form.hu/wp-content/uploads/2015/08/QTRAP6500-and-SelexION... · Detection of Somatostatin with and without SelexION+

4 © 2015 AB Sciex

New Feature Benefit Application

New HED+ detector

technology

Neg Mode: Significant improvement in

signal intensity Q3 fragment mass

< 100 Da

Oligonucleotide quant in neg.

mode with low mass Q3

fragments;

Low M.Wt. biomarkers

New jet injector DMS cell Increased transmission efficiency

(up to 2X increase in signal intensity)

Compounds with poor

MS/MS or non specific

fragments- Steroids, Cyclic

peptides

Reduce matrix background &

chemical interference

Fast polarity switching

speed

As low as 5 msec

Biomarker discovery and multi

target quant with sMRM pro

algorithm

Page 5: QTRAP 6500+ and SelexION+- Improving the Sensitivity, Speed …per-form.hu/wp-content/uploads/2015/08/QTRAP6500-and-SelexION... · Detection of Somatostatin with and without SelexION+

Technology Improvements

Page 6: QTRAP 6500+ and SelexION+- Improving the Sensitivity, Speed …per-form.hu/wp-content/uploads/2015/08/QTRAP6500-and-SelexION... · Detection of Somatostatin with and without SelexION+

6 © 2015 AB Sciex

HED+ Detector Technology

• Larger detection area

• New power supply

‒ High energy dynode at 15 kV improves sensitivity

‒ Enables faster polarity switching

• “Floated” design

‒ Ions in negative polarity directed straight into the

detector

‒ This benefits low mass ions which are detected

much more efficiently

Contributes to significant signal gains in neg. mode Q3 fragment <100 Da

and modest improvements in pos. mode

Page 7: QTRAP 6500+ and SelexION+- Improving the Sensitivity, Speed …per-form.hu/wp-content/uploads/2015/08/QTRAP6500-and-SelexION... · Detection of Somatostatin with and without SelexION+

7 © 2015 AB Sciex

Sensitivity of 6500+ System in Positive Polarity

0.1 pg/mL Testosterone (with SelexION®+ Technology, 50 µL Injection)

Page 8: QTRAP 6500+ and SelexION+- Improving the Sensitivity, Speed …per-form.hu/wp-content/uploads/2015/08/QTRAP6500-and-SelexION... · Detection of Somatostatin with and without SelexION+

8 © 2015 AB Sciex

Linearity of 6500+ System in Positive Polarity

0.1 to 100 pg/mL Testosterone (with SelexION®+ Technology)

0.1 to 5 pg/mL

Accuracies: 92 to 109%

%CV: 3.8% at 0.1 pg/mL

Page 9: QTRAP 6500+ and SelexION+- Improving the Sensitivity, Speed …per-form.hu/wp-content/uploads/2015/08/QTRAP6500-and-SelexION... · Detection of Somatostatin with and without SelexION+

9 © 2015 AB Sciex

Linearity of 6500+ System in Positive Polarity

1 to 100,000 pg/mL Flurazepam (with SelexION®+ Technology)

1 to 1000 pg/mL

5 orders

r > 0.9999

Page 10: QTRAP 6500+ and SelexION+- Improving the Sensitivity, Speed …per-form.hu/wp-content/uploads/2015/08/QTRAP6500-and-SelexION... · Detection of Somatostatin with and without SelexION+

10 © 2015 AB Sciex

HED+ Detector Technology in Negative Mode

6500+

-500 V

+5500 V

+7000 V

Capture more negative ions and increase

ion conversion

• In 6500+ negative ion mode, the ions are

directed straight into the detector

• Use HED+ to deflect the negative ions to

the detector

• Increase overall detector voltage to pull

in negative ions

Larger detection area helps to capture wide spread of ions

Page 11: QTRAP 6500+ and SelexION+- Improving the Sensitivity, Speed …per-form.hu/wp-content/uploads/2015/08/QTRAP6500-and-SelexION... · Detection of Somatostatin with and without SelexION+

12 © 2015 AB Sciex

Sensitivity of 6500+ System in Negative Polarity

1 ng/L (1 part-per-trillion) PFOA and PFOS (Linearity 0.5 to 5000 ng/L)

Quantifier (blue)

Qualifier 1 (purple)

Qualifier 2 (orange)

Quantifier (blue)

Qualifier 1 (purple)

PFOA

PFOS

499/80 499/99

413/369 413/219 413/169

Page 12: QTRAP 6500+ and SelexION+- Improving the Sensitivity, Speed …per-form.hu/wp-content/uploads/2015/08/QTRAP6500-and-SelexION... · Detection of Somatostatin with and without SelexION+

14 © 2015 AB Sciex

Sensitivity of 6500+ System in Negative Polarity

0.1 ng/mL (100 ppt) Monofluoroacetate (Linearity 0.05 – 1000 ng/mL)

77/57 (blue)

77/33 (purple)

Internal standard

81/60 (blue)

81/35 (purple)

Accuracies: 96.1 to 110.9%

%CV: 4.99% at 0.1 pg/mL (n = 10)

Page 13: QTRAP 6500+ and SelexION+- Improving the Sensitivity, Speed …per-form.hu/wp-content/uploads/2015/08/QTRAP6500-and-SelexION... · Detection of Somatostatin with and without SelexION+

15 © 2015 AB Sciex

Ultra Fast Polarity Switching of 6500+ System

Multi-Pesticide Screening for ~300 Analytes with 5 msec Switching

552 MRM transitions

Positive ESI

58 MRM transitions

Negative ESI

Flufenacet CV = 4.37%

Methoxyfenozide CV = 1.52%

Page 14: QTRAP 6500+ and SelexION+- Improving the Sensitivity, Speed …per-form.hu/wp-content/uploads/2015/08/QTRAP6500-and-SelexION... · Detection of Somatostatin with and without SelexION+

16 © 2015 AB Sciex

Multi-Pesticide Screening with 5 msec Polarity Switching

Pesticide Standard and Sample Extracts (Positive Polarity)

1 ng/mL

Tomato (10x)

Banana (10x)

Lemon (10x)

Cucumber (10x)

Strawberry (10x)

Arugula (20x)

Page 15: QTRAP 6500+ and SelexION+- Improving the Sensitivity, Speed …per-form.hu/wp-content/uploads/2015/08/QTRAP6500-and-SelexION... · Detection of Somatostatin with and without SelexION+

17 © 2015 AB Sciex

Multi-Pesticide Screening with 5 msec Polarity Switching

Pesticide Standard and Sample Extracts (Negative Polarity)

1 ng/mL

Tomato (10x)

Banana (10x)

Lemon (10x)

Cucumber (10x)

Strawberry (10x)

Arugula (10x)

Page 16: QTRAP 6500+ and SelexION+- Improving the Sensitivity, Speed …per-form.hu/wp-content/uploads/2015/08/QTRAP6500-and-SelexION... · Detection of Somatostatin with and without SelexION+

New Jet Injector SelexION®+ Technology

Page 17: QTRAP 6500+ and SelexION+- Improving the Sensitivity, Speed …per-form.hu/wp-content/uploads/2015/08/QTRAP6500-and-SelexION... · Detection of Somatostatin with and without SelexION+

19 © 2015 AB Sciex

New Jet Injector SelexION®+ Technology

DMS Electrode 1

DMS Electrode 2

DMS Electrode 1

DMS Electrode 2

Lens

Lens

New DMS Cell Design

‒ Increase ion transmission by 2X

‒ Additional lens increases ion velocities into

the cell

‒ Reduces transit time through detrimental

fringing field

‒ Only available on 6500+ Platform

Continually driving selectivity improvements

Page 18: QTRAP 6500+ and SelexION+- Improving the Sensitivity, Speed …per-form.hu/wp-content/uploads/2015/08/QTRAP6500-and-SelexION... · Detection of Somatostatin with and without SelexION+

20 © 2015 AB Sciex

SelexION®+ Performance Improvements

2X Increase in transmission efficiency with new jet injector

0

5

10

15

20

25

30

Alp

razo

lam

Bu

pre

no

rph

ine

Cle

nb

ute

rol

Met

ham

ph

etam

ine

Re

l. P

eak

Are

a

Resolution Gas = Off

SelexION SelexION+

0

2

4

6

8

10

12

14

16

18

20

Alp

razo

lam

Bu

pre

no

rph

ine

Cle

nb

ute

rol

Met

ham

ph

etam

ine

Re

l. P

eak

Are

a

Resolution Gas = Low

SelexION SelexION+

0

10

20

30

40

50

60

Alp

razo

lam

Bu

pre

no

rph

ine

Cle

nb

ute

rol

Met

ham

ph

etam

ine

Re

l. P

eak

Are

a

Resolution Gas = Open

SelexION SelexION+

~ 2X increase in signal intensity in all DMS resolution settings

Page 19: QTRAP 6500+ and SelexION+- Improving the Sensitivity, Speed …per-form.hu/wp-content/uploads/2015/08/QTRAP6500-and-SelexION... · Detection of Somatostatin with and without SelexION+

21 © 2015 AB Sciex

Cyclic Peptides & Peptides with Poor MS/MS Fragmentation

• Poor MS/MS-cyclic peptide

• Non specific product ions- low mass Q3 fragments

C76H104N18O19S2

1636.7Da

Somatostatin Cyclic Peptide

+2 charge- m/z 819.7

Page 20: QTRAP 6500+ and SelexION+- Improving the Sensitivity, Speed …per-form.hu/wp-content/uploads/2015/08/QTRAP6500-and-SelexION... · Detection of Somatostatin with and without SelexION+

22 © 2015 AB Sciex

Somatostatin Product Ion Spectrum

Product of Q1 819.7 Da

• Poor MS/MS-cyclic peptide

• Non specific product ions- low mass Q3 fragments

Best approach parent to parent quantification but limited by huge background noise

Page 21: QTRAP 6500+ and SelexION+- Improving the Sensitivity, Speed …per-form.hu/wp-content/uploads/2015/08/QTRAP6500-and-SelexION... · Detection of Somatostatin with and without SelexION+

23 © 2015 AB Sciex

SelexION®+ Multiple Ion Monitoring (MIM) Assay

SelexION®+

Technology Parent Ion

Transmission

Parent Ion

Transmission

Interferences

Interferences

Parent Parent No fragmentation in

collision cell

Reduce

Background Noise

Eliminate interferences and achieve cleaner background with SelexION®+ MIM Assay

Page 22: QTRAP 6500+ and SelexION+- Improving the Sensitivity, Speed …per-form.hu/wp-content/uploads/2015/08/QTRAP6500-and-SelexION... · Detection of Somatostatin with and without SelexION+

24 © 2015 AB Sciex

6500+ SelexION®+ MIM Assay-Somatostatin Cyclic Peptide Quant

A) Blank Plasma-With SelexION®+ in MIM

Mode

B) Blank Plasma-Without SelexION®+ in MIM Mode

Low background noise with SelexION+ High background noise without SelexION+

Approx. 10X reduction in background noise with SelexION®+ MIM Assay

MIM- 819.7/819.7 MIM- 819.7/819.7

Page 23: QTRAP 6500+ and SelexION+- Improving the Sensitivity, Speed …per-form.hu/wp-content/uploads/2015/08/QTRAP6500-and-SelexION... · Detection of Somatostatin with and without SelexION+

25 © 2015 AB Sciex

6500+ SelexION®+ Somatostatin Cyclic Peptide Quant Data

S/N 9.6

Accuracy 102.7%

% CV 5.8

No. Inj. 5

A) Blank Plasma-Somatostatin DMS MIM B) 50 pg/mL LOQ in Rat Plasma-Somatostatin DMS MIM

MIM- 819.7/819.7 MIM- 819.7/819.7

Page 24: QTRAP 6500+ and SelexION+- Improving the Sensitivity, Speed …per-form.hu/wp-content/uploads/2015/08/QTRAP6500-and-SelexION... · Detection of Somatostatin with and without SelexION+

26 © 2015 AB Sciex

A) Calibration Curve: 0.05 ng/mL-2500 ng/mL

R= 0.9934

B) GLP Level accuracy: 88.9%-110.2%; Precision: <9%

6500+ SelexION®+ Somatostatin Cyclic Peptide Quant Data

Somatostatin SelexION®+ MIM Assay in Rat Plasma

Page 25: QTRAP 6500+ and SelexION+- Improving the Sensitivity, Speed …per-form.hu/wp-content/uploads/2015/08/QTRAP6500-and-SelexION... · Detection of Somatostatin with and without SelexION+

27 © 2015 AB Sciex

6500+ SelexION®+ Robustness Data in Crashed Plasma: 4000 Injections

0.00

0.50

1.00

1.50

2.00

2.50

3.00

0 500 1000 1500 2000 2500 3000 3500 4000

Pe

ak A

rea

Rat

io

Number of Injections

Methamphetamine 2.7 %CV Alprazolam 3.5% CV

Clenbuterol 2.8 %CV Buprenorphine 7.8 %CV

Repeatability of 4000 injections (crashed human plasma (1:3) diluted 1:2)

Page 26: QTRAP 6500+ and SelexION+- Improving the Sensitivity, Speed …per-form.hu/wp-content/uploads/2015/08/QTRAP6500-and-SelexION... · Detection of Somatostatin with and without SelexION+

28 © 2015 AB Sciex

6500+ SelexION®+ Robustness Data in Crashed Plasma: 4000 Injections

Buprenorphine - % CV- 7.8

Clenbuterol- %CV-2.8

1st Injection 1000th Injection 2000th Injection 3000th Injection 4000th Injection

Proven Performance for Robust and Rugged Bioanalytical Assays

Page 27: QTRAP 6500+ and SelexION+- Improving the Sensitivity, Speed …per-form.hu/wp-content/uploads/2015/08/QTRAP6500-and-SelexION... · Detection of Somatostatin with and without SelexION+

29 © 2015 AB Sciex

Detection of Somatostatin with and without SelexION+

6500+ DMS removed 6500+ with DMS

Somatostatin, a cyclic peptide with poor MS/MS fragmentation is acquired using MIM (819.7/

819.7) assay in rat plasma showing high background noise limiting the S/N ratio and LOQ

Highly reduced background noise enabling desirable LOQ of 100 pg/mL using new SelexION+ jet

injector on 6500+ System (S/N ratio = 12, accuracy = 101% and %CV < 10% )

100 pg/mL

Page 28: QTRAP 6500+ and SelexION+- Improving the Sensitivity, Speed …per-form.hu/wp-content/uploads/2015/08/QTRAP6500-and-SelexION... · Detection of Somatostatin with and without SelexION+

30 © 2015 AB Sciex

Audible Noise Reduction

• Active (source exhaust modifications)

‒ Source exhaust flow minimized to match gas load

• Passive (quieter tubing)

‒ Eliminate “whistling” noise

• Quieter system operation

‒ Noticeable under most source conditions

‒ No impact on sensitivity

Decreased audible noise for a more comfortable work environment

Page 29: QTRAP 6500+ and SelexION+- Improving the Sensitivity, Speed …per-form.hu/wp-content/uploads/2015/08/QTRAP6500-and-SelexION... · Detection of Somatostatin with and without SelexION+

31 © 2015 AB Sciex

The New SCIEX 6500+ Series with HED+ Detector Technology

• Sensitivity boost with “new HED+ detector

technology”

• Enhanced SelexION performance with

“new jet injector DMS cell” without

compromising resolution

• Fast polarity switching speed (5 msec)

• Audible noise reduction

Industry proven performance: IonDrive™ Turbo V™ ion source and QJet® ion guide

Page 30: QTRAP 6500+ and SelexION+- Improving the Sensitivity, Speed …per-form.hu/wp-content/uploads/2015/08/QTRAP6500-and-SelexION... · Detection of Somatostatin with and without SelexION+

32 © 2015 AB Sciex

Acknowledgements

• Sylvie Beaudet

• Tom Biesenthal

• Bruce Collings

• Bradley Schneider

• Andre Schreiber

• Michael Jarvis

• Tanya Gamble

• Gary Impey

• Shaw Xia

• Elliot Jones

• Steve Taylor

• Heather Hughes

• Tony Romanelli

• Kelli Jonakin

Page 31: QTRAP 6500+ and SelexION+- Improving the Sensitivity, Speed …per-form.hu/wp-content/uploads/2015/08/QTRAP6500-and-SelexION... · Detection of Somatostatin with and without SelexION+

33 © 2015 AB Sciex

Trademarks/Licensing

For Research Use Only. Not for use in diagnostic procedures.

© 2015 AB Sciex. The trademarks mentioned herein are

the property of AB Sciex Pte. Ltd. or their respective owners.

AB SCIEX™ is being used under license.

Page 32: QTRAP 6500+ and SelexION+- Improving the Sensitivity, Speed …per-form.hu/wp-content/uploads/2015/08/QTRAP6500-and-SelexION... · Detection of Somatostatin with and without SelexION+