26
Qualified Partner Program Connectors for field termination Felice Guarna, Training Program Manager Wetzikon, January 2006

Qualified Partner Program Connectors for field termination Felice Guarna, Training Program Manager Wetzikon, January 2006

Embed Size (px)

Citation preview

Page 1: Qualified Partner Program Connectors for field termination Felice Guarna, Training Program Manager Wetzikon, January 2006

Qualified Partner Program

Connectors for field termination

Felice Guarna, Training Program Manager

Wetzikon, January 2006

Page 2: Qualified Partner Program Connectors for field termination Felice Guarna, Training Program Manager Wetzikon, January 2006

R&M range_connectors for field termination / Page 2Jan. 2006

Why a pre-polished connector for field termination

LAN ENVIRONMENT

Mid/low number of FO connectors

Terminations mostly on break-out cable

Short links, limited testing equipments (power meter very seldom OTDR)

Good, reliable, quick connections

LAN INSTALLERS

Mid/low experience with FO termination

Manual skill not improvable because of termination quantity/frequency

Limited tools and consumable availability

Page 3: Qualified Partner Program Connectors for field termination Felice Guarna, Training Program Manager Wetzikon, January 2006

R&M range_connectors for field termination / Page 3Jan. 2006

Cost

Connector with very limited tools and no consumable

Very fast and secure termination

No scrap for termination and polishing errors

No need or very limited training

Quality

Factory polished and tested connector gives better performance

Suitable for all LAN applications where APC is not required (CATV)

Must to meet Standard requirement for APC, SPC, UPC

Why a pre-polished connector for field termination

Page 4: Qualified Partner Program Connectors for field termination Felice Guarna, Training Program Manager Wetzikon, January 2006

R&M range_connectors for field termination / Page 4Jan. 2006

Pre-polished connector for field termination

Functional parts

prepolished fiber stub

coupling medium(index mating gel)

Ceramic ferrule with factorypolished end face

The upper part of the plug is opened with a "wedge" (here not shown). This opens the space to introduce a field stripped and cleaved fiber from the rear. Closing the upper part the fiber will be fixed and hold in place.

Page 5: Qualified Partner Program Connectors for field termination Felice Guarna, Training Program Manager Wetzikon, January 2006

R&M range_connectors for field termination / Page 5Jan. 2006

Connectors for field termination

Ceramic ferrule Factory polished tip Reliable and proved technology Low insertion loss > 500 mating cycles Connector surface inspected Commonality through various types

same toolssame installation technique

Features

Construction of the connector

ferrule field fiber

Mechanical Splice

Page 6: Qualified Partner Program Connectors for field termination Felice Guarna, Training Program Manager Wetzikon, January 2006

R&M range_connectors for field termination / Page 6Jan. 2006

Connectors range for field termination

Functional specifications

Compatible with customary SC, LC, ST Low insertion loss ( < 0.5dB ) Multimode and Singlemode fibers For 50/125 and 62.5/125 Suitable for Mini-Breakout cables (900µm)

and breakout cables up to 3mm Ø (SC, ST)

SC

LC

ST

Page 7: Qualified Partner Program Connectors for field termination Felice Guarna, Training Program Manager Wetzikon, January 2006

R&M range_connectors for field termination / Page 7Jan. 2006

Connectors for field termination

Features

Easy handling Light and compact design Power supply independent Three tools in one kit (SC, LC and ST) Suitable for solid and dry tight buffer

Standard Tool Kit

Crimping tools Fiber cleaver Tweezers Jacket stripper Primary coating stripper Secondary coating stripper Length gauge Kevlar scissors Ferrules crimping aid Alcohol wipes and adhesive tape Instruction manual

Supply

Page 8: Qualified Partner Program Connectors for field termination Felice Guarna, Training Program Manager Wetzikon, January 2006

R&M range_connectors for field termination / Page 8Jan. 2006

Connectors for field termination

Optional components for Standard Tool Kit

Continuity Test System CTS

CTS (Continuity Test System) allows to

check the quality of fiber splice.

Light is not be visible in the cam area if

splice action is successfully completed.

If light is visible, splice procedure must be

repeated from beginning to ensure optimum

installation.

Red light source

Standard Patch-Cord

Crimp tool

Connector adapters

Page 9: Qualified Partner Program Connectors for field termination Felice Guarna, Training Program Manager Wetzikon, January 2006

R&M range_connectors for field termination / Page 9Jan. 2006

SC-RJ – the smallest in its class

Page 10: Qualified Partner Program Connectors for field termination Felice Guarna, Training Program Manager Wetzikon, January 2006

R&M range_connectors for field termination / Page 10Jan. 2006

SC-RJ talents

the smallest SC-Duplex fiber optic connector (SFF) with

a unique mechanical security system for

data, audio and video communication

with

a high and reliable performancesuitable for

any F.O. technology

Page 11: Qualified Partner Program Connectors for field termination Felice Guarna, Training Program Manager Wetzikon, January 2006

R&M range_connectors for field termination / Page 11Jan. 2006

SC-RJ adapter standardization ed in EN50377-6

Plug standardized in EN50377-6work item for IEC IEC 61754-x

Adapter standardized in EN50377-6

Suitable for any standard Simplex SC connector

Page 12: Qualified Partner Program Connectors for field termination Felice Guarna, Training Program Manager Wetzikon, January 2006

R&M range_connectors for field termination / Page 12Jan. 2006

SC-RJ can take them all

Singlemode (SM)Multimode (MM)

Page 13: Qualified Partner Program Connectors for field termination Felice Guarna, Training Program Manager Wetzikon, January 2006

R&M range_connectors for field termination / Page 13Jan. 2006

SC-RJ connector

Characteristics

- Push-Pull-System

- 2,5 mm Ceramic precision-ferrule

(metallic for POF only)

- Low insertion loss

- Polarized

- Field terminable

- Color coding on both sides (8 colors)

Page 14: Qualified Partner Program Connectors for field termination Felice Guarna, Training Program Manager Wetzikon, January 2006

R&M range_connectors for field termination / Page 14Jan. 2006

SC-RJ Adapter

Characteristics

- Fits in all R&M RJ45-cut outs

- Precision PhBr sleeves for multimode

- Precision ceramic sleeves for singlemode

- SC-Simplex compatible

Page 15: Qualified Partner Program Connectors for field termination Felice Guarna, Training Program Manager Wetzikon, January 2006

R&M range_connectors for field termination / Page 15Jan. 2006

SC-RJ tests and performance - optical

Multimode (OM2) Singlemode (OS1) SI-POF (980/1000) Standard

Test

Wavelength 1300 nm 30 nm 1310 nm 30 nm 660 nm 30 nm

Type of cable I-V(ZN)H I-V(ZN)H I-V 2Y DIN/VDE

Optical

Attenuation

EN 61300-3-34Max. 0,75 dB 0,80 dB

95% 0,50 dB   0,60 dB n.a.

Mean. 0,35 dB  0,30 dB 0,40 dB

Return loss 20 dB Class R:  40 dB n.a. EN 61300-3-6

Page 16: Qualified Partner Program Connectors for field termination Felice Guarna, Training Program Manager Wetzikon, January 2006

R&M range_connectors for field termination / Page 16Jan. 2006

SC-RJ tests and performance - mechanical

Multimode (OM2) Singlemode (OS1) SI-POF (980/1000) Standard

Test

Wavelength 1300 nm 30 nm 1310 nm 30 nm 660 nm 30 nm

Mechanical

Strength of coupling mechanism

EN 61300-2-6Load 40 N 40 N 40 NDuration of the load 1 min 2 min 1 min

Mating durabilityEN 61300-2-2

Number of cycles 500 500 500Vibration (sinusoidal)

EN 61300-2-1Octave/min 10 - 55 Hz 10 - 55 Hz 10 - 500 Hz Amplitude 0,75 mm 0,75 mm 0,35 mm

Impact

EN 61300-2-12Number of drops 5 5 5Drop height 1,5 m 1,5 m 1,5 m

Cable retention connector

EN 61300-2-4Tensile force 100 N 100 N 50 NDuration 2 min 2 min 2 min

Page 17: Qualified Partner Program Connectors for field termination Felice Guarna, Training Program Manager Wetzikon, January 2006

R&M range_connectors for field termination / Page 17Jan. 2006

SC-RJ tests and performance - environmental

Multimode (OM2) Singlemode (OS1) SI-POF (980/1000) Standard

Test

Wavelength 1300 nm 30 nm 1310 nm 30 nm 660 nm 30 nm

Environmental

Cold

EN 61300-2-17Temperature - 10 °C - 25 °C - 10 °C Duration 96 h 96 h 96 h

Dry heat

EN 61300-2-18Temperature + 60 °C + 70 °C + 60 °CDuration 96 h 96 h 96 h

Damp heat (steady state)

EN 61300-2-19Temperature + 40 °C + 40 °C + 40 °C Duration 96 h 96 h 96 hrelative humidity 93 % 93 % 93 %

Change of temperature - 10 °C / + 60 °C - 25 °C / + 70 °C - 10 °C / + 60 °C

EN 61300-2-22Temperature - 10 °C / + 60 °C - 25 °C / + 70 °C - 10 °C / + 60 °CDuration at max. temperature 1 h 1 h 1 h

Attenuation change for all tests

passedAttenuation  0,20 dB  0,20 dB Wavelength 1300nm 1550nm

Page 18: Qualified Partner Program Connectors for field termination Felice Guarna, Training Program Manager Wetzikon, January 2006

R&M range_connectors for field termination / Page 18Jan. 2006

Applications : patch cords

R&M patch cords are delivered with color clips defining the type of fiber.

Fiber definition

62.5/125 (OM1) → anthracite

50/125 (OM2) → orange

50/125 (OM3) → turquoise

9/125 (OS1) → blue or green

980/1000 → yellow

200/230 → violet

Page 19: Qualified Partner Program Connectors for field termination Felice Guarna, Training Program Manager Wetzikon, January 2006

R&M range_connectors for field termination / Page 19Jan. 2006

With mounting plate for flexible mounting in one channel holders in

- 19” patch panel

- WM box

- WM outlet

- FM outlet

- Consolidation point-

One channel module holder

Applications : terminal outlets and patch panels

Page 20: Qualified Partner Program Connectors for field termination Felice Guarna, Training Program Manager Wetzikon, January 2006

R&M range_connectors for field termination / Page 20Jan. 2006

Applications : 19” patch panelsdirect (one channel holder) and by fiberliner

1U Patch panel 3U patch panel

16 Port (32 fibers)

12 Port (24 fibers)

60 Port (120 fibers)

- splice version

- for preassembled cables

- field termination

Page 21: Qualified Partner Program Connectors for field termination Felice Guarna, Training Program Manager Wetzikon, January 2006

R&M range_connectors for field termination / Page 21Jan. 2006

Applications : 24 port patch panel Snap-In

Extra adapter frame for flexible mounting in any materials

One frame for two mounting surface thicknesses

Including color coding (8 colors)

Page 22: Qualified Partner Program Connectors for field termination Felice Guarna, Training Program Manager Wetzikon, January 2006

R&M range_connectors for field termination / Page 22Jan. 2006

SC-RJ Snap-In

Easy, fast and reusable, flexible

Flexible mounting in hole pattern 14.9 mm x 19.5 mm

in materials with wall thickness 1.5 mm or 2.0 mm

1.5 2.0

Page 23: Qualified Partner Program Connectors for field termination Felice Guarna, Training Program Manager Wetzikon, January 2006

R&M range_connectors for field termination / Page 23Jan. 2006

Applications : for Snap-In

19" 1HE 24 Port Patch Panel for max. 24 adapters (48 fibers!)

Snap-In SC-RJ SM, MM and POF

Snap-In E-2000 Compact for SM and MM

Or combined with RJ45 connection modules

Page 24: Qualified Partner Program Connectors for field termination Felice Guarna, Training Program Manager Wetzikon, January 2006

R&M range_connectors for field termination / Page 24Jan. 2006

Applications : P.C.B. mounted for Active Components

Page 25: Qualified Partner Program Connectors for field termination Felice Guarna, Training Program Manager Wetzikon, January 2006

R&M range_connectors for field termination / Page 25Jan. 2006

Security level 1

Visual color coding

- On connector and coding frame

- 8 different colors blue, green, red, orange, anthracite, violet, yellow, turquoise

Security level 3

Mechanical plug-IN protection

– adapter guard protection against inadvertently connection

- Key to unlock adapter guard

Mechanical plug-OUT protection

- fiber guard – protection against inadvertently disconnection

- Key to unlock fiber guard

Applications : Security options

Page 26: Qualified Partner Program Connectors for field termination Felice Guarna, Training Program Manager Wetzikon, January 2006

R&M range_connectors for field termination / Page 26Jan. 2006

Expanding connectors choice with pigtail assembly

When connectors performance are extremely demanding, pigtails for mechanical or fusion splice offer the best value

For single mode installation

For APC finishing

For termination of out of size cables

For economic and quick installation