Qualified Partner Program
Connectors for field termination
Felice Guarna, Training Program Manager
Wetzikon, January 2006
R&M range_connectors for field termination / Page 2Jan. 2006
Why a pre-polished connector for field termination
LAN ENVIRONMENT
Mid/low number of FO connectors
Terminations mostly on break-out cable
Short links, limited testing equipments (power meter very seldom OTDR)
Good, reliable, quick connections
LAN INSTALLERS
Mid/low experience with FO termination
Manual skill not improvable because of termination quantity/frequency
Limited tools and consumable availability
R&M range_connectors for field termination / Page 3Jan. 2006
Cost
Connector with very limited tools and no consumable
Very fast and secure termination
No scrap for termination and polishing errors
No need or very limited training
Quality
Factory polished and tested connector gives better performance
Suitable for all LAN applications where APC is not required (CATV)
Must to meet Standard requirement for APC, SPC, UPC
Why a pre-polished connector for field termination
R&M range_connectors for field termination / Page 4Jan. 2006
Pre-polished connector for field termination
Functional parts
prepolished fiber stub
coupling medium(index mating gel)
Ceramic ferrule with factorypolished end face
The upper part of the plug is opened with a "wedge" (here not shown). This opens the space to introduce a field stripped and cleaved fiber from the rear. Closing the upper part the fiber will be fixed and hold in place.
R&M range_connectors for field termination / Page 5Jan. 2006
Connectors for field termination
Ceramic ferrule Factory polished tip Reliable and proved technology Low insertion loss > 500 mating cycles Connector surface inspected Commonality through various types
same toolssame installation technique
Features
Construction of the connector
ferrule field fiber
Mechanical Splice
R&M range_connectors for field termination / Page 6Jan. 2006
Connectors range for field termination
Functional specifications
Compatible with customary SC, LC, ST Low insertion loss ( < 0.5dB ) Multimode and Singlemode fibers For 50/125 and 62.5/125 Suitable for Mini-Breakout cables (900µm)
and breakout cables up to 3mm Ø (SC, ST)
SC
LC
ST
R&M range_connectors for field termination / Page 7Jan. 2006
Connectors for field termination
Features
Easy handling Light and compact design Power supply independent Three tools in one kit (SC, LC and ST) Suitable for solid and dry tight buffer
Standard Tool Kit
Crimping tools Fiber cleaver Tweezers Jacket stripper Primary coating stripper Secondary coating stripper Length gauge Kevlar scissors Ferrules crimping aid Alcohol wipes and adhesive tape Instruction manual
Supply
R&M range_connectors for field termination / Page 8Jan. 2006
Connectors for field termination
Optional components for Standard Tool Kit
Continuity Test System CTS
CTS (Continuity Test System) allows to
check the quality of fiber splice.
Light is not be visible in the cam area if
splice action is successfully completed.
If light is visible, splice procedure must be
repeated from beginning to ensure optimum
installation.
Red light source
Standard Patch-Cord
Crimp tool
Connector adapters
R&M range_connectors for field termination / Page 9Jan. 2006
SC-RJ – the smallest in its class
R&M range_connectors for field termination / Page 10Jan. 2006
SC-RJ talents
the smallest SC-Duplex fiber optic connector (SFF) with
a unique mechanical security system for
data, audio and video communication
with
a high and reliable performancesuitable for
any F.O. technology
R&M range_connectors for field termination / Page 11Jan. 2006
SC-RJ adapter standardization ed in EN50377-6
Plug standardized in EN50377-6work item for IEC IEC 61754-x
Adapter standardized in EN50377-6
Suitable for any standard Simplex SC connector
R&M range_connectors for field termination / Page 12Jan. 2006
SC-RJ can take them all
Singlemode (SM)Multimode (MM)
R&M range_connectors for field termination / Page 13Jan. 2006
SC-RJ connector
Characteristics
- Push-Pull-System
- 2,5 mm Ceramic precision-ferrule
(metallic for POF only)
- Low insertion loss
- Polarized
- Field terminable
- Color coding on both sides (8 colors)
R&M range_connectors for field termination / Page 14Jan. 2006
SC-RJ Adapter
Characteristics
- Fits in all R&M RJ45-cut outs
- Precision PhBr sleeves for multimode
- Precision ceramic sleeves for singlemode
- SC-Simplex compatible
R&M range_connectors for field termination / Page 15Jan. 2006
SC-RJ tests and performance - optical
Multimode (OM2) Singlemode (OS1) SI-POF (980/1000) Standard
Test
Wavelength 1300 nm 30 nm 1310 nm 30 nm 660 nm 30 nm
Type of cable I-V(ZN)H I-V(ZN)H I-V 2Y DIN/VDE
Optical
Attenuation
EN 61300-3-34Max. 0,75 dB 0,80 dB
95% 0,50 dB 0,60 dB n.a.
Mean. 0,35 dB 0,30 dB 0,40 dB
Return loss 20 dB Class R: 40 dB n.a. EN 61300-3-6
R&M range_connectors for field termination / Page 16Jan. 2006
SC-RJ tests and performance - mechanical
Multimode (OM2) Singlemode (OS1) SI-POF (980/1000) Standard
Test
Wavelength 1300 nm 30 nm 1310 nm 30 nm 660 nm 30 nm
Mechanical
Strength of coupling mechanism
EN 61300-2-6Load 40 N 40 N 40 NDuration of the load 1 min 2 min 1 min
Mating durabilityEN 61300-2-2
Number of cycles 500 500 500Vibration (sinusoidal)
EN 61300-2-1Octave/min 10 - 55 Hz 10 - 55 Hz 10 - 500 Hz Amplitude 0,75 mm 0,75 mm 0,35 mm
Impact
EN 61300-2-12Number of drops 5 5 5Drop height 1,5 m 1,5 m 1,5 m
Cable retention connector
EN 61300-2-4Tensile force 100 N 100 N 50 NDuration 2 min 2 min 2 min
R&M range_connectors for field termination / Page 17Jan. 2006
SC-RJ tests and performance - environmental
Multimode (OM2) Singlemode (OS1) SI-POF (980/1000) Standard
Test
Wavelength 1300 nm 30 nm 1310 nm 30 nm 660 nm 30 nm
Environmental
Cold
EN 61300-2-17Temperature - 10 °C - 25 °C - 10 °C Duration 96 h 96 h 96 h
Dry heat
EN 61300-2-18Temperature + 60 °C + 70 °C + 60 °CDuration 96 h 96 h 96 h
Damp heat (steady state)
EN 61300-2-19Temperature + 40 °C + 40 °C + 40 °C Duration 96 h 96 h 96 hrelative humidity 93 % 93 % 93 %
Change of temperature - 10 °C / + 60 °C - 25 °C / + 70 °C - 10 °C / + 60 °C
EN 61300-2-22Temperature - 10 °C / + 60 °C - 25 °C / + 70 °C - 10 °C / + 60 °CDuration at max. temperature 1 h 1 h 1 h
Attenuation change for all tests
passedAttenuation 0,20 dB 0,20 dB Wavelength 1300nm 1550nm
R&M range_connectors for field termination / Page 18Jan. 2006
Applications : patch cords
R&M patch cords are delivered with color clips defining the type of fiber.
Fiber definition
62.5/125 (OM1) → anthracite
50/125 (OM2) → orange
50/125 (OM3) → turquoise
9/125 (OS1) → blue or green
980/1000 → yellow
200/230 → violet
R&M range_connectors for field termination / Page 19Jan. 2006
With mounting plate for flexible mounting in one channel holders in
- 19” patch panel
- WM box
- WM outlet
- FM outlet
- Consolidation point-
One channel module holder
Applications : terminal outlets and patch panels
R&M range_connectors for field termination / Page 20Jan. 2006
Applications : 19” patch panelsdirect (one channel holder) and by fiberliner
1U Patch panel 3U patch panel
16 Port (32 fibers)
12 Port (24 fibers)
60 Port (120 fibers)
- splice version
- for preassembled cables
- field termination
R&M range_connectors for field termination / Page 21Jan. 2006
Applications : 24 port patch panel Snap-In
Extra adapter frame for flexible mounting in any materials
One frame for two mounting surface thicknesses
Including color coding (8 colors)
R&M range_connectors for field termination / Page 22Jan. 2006
SC-RJ Snap-In
Easy, fast and reusable, flexible
Flexible mounting in hole pattern 14.9 mm x 19.5 mm
in materials with wall thickness 1.5 mm or 2.0 mm
1.5 2.0
R&M range_connectors for field termination / Page 23Jan. 2006
Applications : for Snap-In
19" 1HE 24 Port Patch Panel for max. 24 adapters (48 fibers!)
Snap-In SC-RJ SM, MM and POF
Snap-In E-2000 Compact for SM and MM
Or combined with RJ45 connection modules
R&M range_connectors for field termination / Page 24Jan. 2006
Applications : P.C.B. mounted for Active Components
R&M range_connectors for field termination / Page 25Jan. 2006
Security level 1
Visual color coding
- On connector and coding frame
- 8 different colors blue, green, red, orange, anthracite, violet, yellow, turquoise
Security level 3
Mechanical plug-IN protection
– adapter guard protection against inadvertently connection
- Key to unlock adapter guard
Mechanical plug-OUT protection
- fiber guard – protection against inadvertently disconnection
- Key to unlock fiber guard
Applications : Security options
R&M range_connectors for field termination / Page 26Jan. 2006
Expanding connectors choice with pigtail assembly
When connectors performance are extremely demanding, pigtails for mechanical or fusion splice offer the best value
For single mode installation
For APC finishing
For termination of out of size cables
For economic and quick installation