RADIANT CEILING HEATER SYSTEMSwith Wireless Time and Temperature Control
Wireless Heating Systems
Radiant heat is directional heat, so radiant panels will project heat in a straight line from the heater and warm anyone or anything in its path whichever direction its pointed in.
Ceiling radiators will project heat straight down and will warm people under the heaters. Hence the attraction of energy efficient radiant electric heating panels.
EFS 1018 v14 07/21
All local space heaters manufactured for sale in the EU after 1st January 2018 which use electricity, gaseous or liquid fuels, must comply with a minimum efficiency standard. This includes electric radiators, electric underfloor heating and electric and gas fires.
PROUDLY MANUFACTURED IN THE UK
Member
Lot 20 compliant
Available from electric wholesalers and NICEIC engineers
600
1200
38 2
25
595
AERIAL
POWER SWITCH
POWER LEAD
LED INDICATOR
TEE BAR SUSPENDED CEILINGNEMA G - 25 WIDE ON 600 GRID PATTERN
TEE BAR SUSPENDEDCEILING PANEL
Genie 595x1195
DEERFOLD
WEIGHT:
A1
SHEET 1 OF 1SCALE:1:2
DWG NO.
TITLE:
REVISIONDO NOT SCALE DRAWING
MATERIAL:
DATESIGNATURENAME
DEBUR AND BREAK SHARP EDGES
FINISH:UNLESS OTHERWISE SPECIFIED:DIMENSIONS ARE IN MILLIMETERSSURFACE FINISH:TOLERANCES: LINEAR: ANGULAR:
Q.A
MFG
APPV'D
CHK'D
DRAWN
ECO 300/80/FF/RP/PC/RX595x595mm ’T’ Grid
ECO 600/80/FF/RP/PC/RX595x1195mm ’T’ Grid
T-BAR SUSPENDED RADIANT PANEL SYSTEM
LINEAR RADIANT PANEL SYSTEM
1500
250
110
24
38.
8 74.
8
40 1200
TELL TALE LEDON FRONT FACE
A
NOTESMATL: 1.0 / 1.5 STEEL, ZINC PASSIVATEDFINISH: POWDER COAT WHITE - RAL 9016PROTECTION: IP44
OPTIONAL HANGING RAIL ARRANGEMENT
DETAIL A SCALE 2 : 5
POWER SWITCH RECEIVER AERIAL
THIS DRAWING IS THE SOLE PROPERTY OF ECOLECAND SHOULD NOT BE COPIED OR REPRODUCEDWITHOUT THE WRITTEN PERMISSION OF ECOLEC
Ecolec LtdSharrocks StWolverhamptonWest MidlandsWV1 3RP01902 457 575www.ecolec.co.uk
LINEAR RADIANT PANEL250 x 1500
DISCREET FASTENING
LR 250x1500_141005
05.10.14DEERFOLD
WEIGHT:
POWDER COAT WHITERAL 9016
0.9 ZINTECA1
SHEET 1 OF 4SCALE:1:3
DWG NO.
TITLE:
REVISIONDO NOT SCALE DRAWING
MATERIAL:
DATESIGNATURENAME
DEBUR AND BREAK SHARP EDGES
FINISH:UNLESS OTHERWISE SPECIFIED:DIMENSIONS ARE IN MILLIMETERSSURFACE FINISH:TOLERANCES: LINEAR: ANGULAR:
Q.A
MFG
APPV'D
CHK'D
DRAWN
DETAIL A SCALE 2 : 5
POWER SWITCH RECEIVER AERIALRECEIVER AERIAL
1500
250
110
24
38.
8 74.
8
40 1200
TELL TALE LEDON FRONT FACE
A
NOTESMATL: 1.0 / 1.5 STEEL, ZINC PASSIVATEDFINISH: POWDER COAT WHITE - RAL 9016PROTECTION: IP44
OPTIONAL HANGING RAIL ARRANGEMENT
DETAIL A SCALE 2 : 5
POWER SWITCH RECEIVER AERIAL
THIS DRAWING IS THE SOLE PROPERTY OF ECOLECAND SHOULD NOT BE COPIED OR REPRODUCEDWITHOUT THE WRITTEN PERMISSION OF ECOLEC
Ecolec LtdSharrocks StWolverhamptonWest MidlandsWV1 3RP01902 457 575www.ecolec.co.uk
LINEAR RADIANT PANEL250 x 1500
DISCREET FASTENING
LR 250x1500_141005
05.10.14DEERFOLD
WEIGHT:
POWDER COAT WHITERAL 9016
0.9 ZINTECA1
SHEET 1 OF 4SCALE:1:3
DWG NO.
TITLE:
REVISIONDO NOT SCALE DRAWING
MATERIAL:
DATESIGNATURENAME
DEBUR AND BREAK SHARP EDGES
FINISH:UNLESS OTHERWISE SPECIFIED:DIMENSIONS ARE IN MILLIMETERSSURFACE FINISH:TOLERANCES: LINEAR: ANGULAR:
Q.A
MFG
APPV'D
CHK'D
DRAWN
ECO 1000/CE/RP/PC/RX
ECO 1000/CE/RP/PC/RX
ECO 1000/CE/RP/PC/RX
SUSPENDED RADIANT PANEL SYSTEM
A
DETAIL A SCALE 2 : 1.5
Genie hanging (2) 500x1500
18.02.13Deerfold
WEIGHT:
A1
SHEET 1 OF 1SCALE:1:1.5
DWG NO.
TITLE:
REVISIONDO NOT SCALE DRAWING
MATERIAL:
DATESIGNATURENAME
DEBUR AND BREAK SHARP EDGES
FINISH:UNLESS OTHERWISE SPECIFIED:DIMENSIONS ARE IN MILLIMETERSSURFACE FINISH:TOLERANCES: LINEAR: ANGULAR:
Q.A
MFG
APPV'D
CHK'D
DRAWN
1000
750
GAP TO SUIT CLIENT
5871
240V MAINSOR BATTERY POWEREDMODELS AVAILABLE
ECOLEC CONTROLLER
1 CONTROLLER FOR MULTIPLE HEATERS30m RANGE
THIS DRAWING IS THE SOLE PROPERTY OF ECOLECAND SHOULD NOT BE COPIED OR REPRODUCEDWITHOUT THE WRITTEN PERMISSION OF ECOLEC
Ecolec LtdSharrocks StWolverhamptonWest MidlandsWV1 3RP01902 457 575www.ecolec.co.uk
750 X 1000
750x1000 FF_assy_140622
22.06.14Deerfold
WEIGHT:
A1
SHEET 2 OF 2SCALE:1:5
DWG NO.
TITLE:
REVISIONDO NOT SCALE DRAWING
MATERIAL:
DATESIGNATURENAME
DEBUR AND BREAK SHARP EDGES
FINISH:UNLESS OTHERWISE SPECIFIED:DIMENSIONS ARE IN MILLIMETERSSURFACE FINISH:TOLERANCES: LINEAR: ANGULAR:
Q.A
MFG
APPV'D
CHK'D
DRAWN
ECO 750X/CE/RP/PC/RX
ECO 750X/CE/RP/PC/RX
SUSPENDED RADIANT PANEL SYSTEM
Ecolec hangingwire c/w foot
Ferrule
M4x4 grub screwM4x4 grub screw
2 AF Hex key2 AF Hex key(supplied)(supplied)
Supplied with fi xing kit.Supplied with fi xing kit.
CEILING MOUNTED ANTI-LIGATURE OPTIONS
D
NOTES ON CEILING INSTALLATIONHEATER MUST BE SECURELY MOUNTEDIDEALLY INTO CEILING JOISTS
1000
500
1500
500
2000
500
PA
NEL
SIZ
E 4
4 F
IXIN
G
MULTIPLE SLOTS TO SECURE TO CEILING
C
HANGING WIRE SYSTEMUSED ON SUSPENDED CEILING TYPE PANEL
DETAIL C
SCALE 2 : 5
ECOLEC HEATER CASE FLUSH FIT DESIGNFOR SUSPENDED CEILING GRIDS
DETAIL D
SCALE 1 : 2.5
SCREW TO SUIT CEILINGCONSTRUCTION - NOM. No.5 x 40 LONG
PANEL HEATER
CEILING JOIST
NYLON SPACER(OPTIONAL)
PLASTER BOARD
CONNECT CABLEIN CEILING VOID
Ecolec LtdSharrocks StWolverhamptonWest MidlandsWV1 3RP01902 457 575www.ecolec.co.uk
THIS DRAWING IS THE SOLE PROPERTY OF ECOLECAND SHOULD NOT BE COPIED OR REPRODUCEDWITHOUT THE WRITTEN PERMISSION OF ECOLEC
NOTE. FOR ANTI-LIGATURE APPLICATIONSPECIAL FIXINGS AND APPLICATOR TOOLCAN BE SUPPLIED
A A
B B
C C
D D
E E
F F
G G
H H
J J
K K
L L
M M
16
16
15
15
14
14
13
13
12
12
11
11
10
10
9
9
8
8
7
7
6
6
5
5
4
4
3
3
2
2
1
1
DRAWN
CHK'D
APPV'D
MFG
Q.A
UNLESS OTHERWISE SPECIFIED:DIMENSIONS ARE IN MILLIMETERSSURFACE FINISH:TOLERANCES: LINEAR: ANGULAR:
FINISH: DEBURR AND BREAK SHARP EDGES
NAME SIGNATURE DATE
MATERIAL:
DO NOT SCALE DRAWING REVISION
TITLE:
DWG NO.
SCALE:1:5 SHEET 1 OF 1
A1
WEIGHT:
DEERFOLD 17.09.18
Ceiling Mounting_180917
CEILING MOUNTING OPTIONS
D
NOTES ON CEILING INSTALLATIONHEATER MUST BE SECURELY MOUNTEDIDEALLY INTO CEILING JOISTS
1000
500
1500
500
2000
500
PA
NEL
SIZ
E 4
4 F
IXIN
G
MULTIPLE SLOTS TO SECURE TO CEILING
C
HANGING WIRE SYSTEMUSED ON SUSPENDED CEILING TYPE PANEL
DETAIL C
SCALE 2 : 5
ECOLEC HEATER CASE FLUSH FIT DESIGNFOR SUSPENDED CEILING GRIDS
DETAIL D
SCALE 1 : 2.5
SCREW TO SUIT CEILINGCONSTRUCTION - NOM. No.5 x 40 LONG
PANEL HEATER
CEILING JOIST
NYLON SPACER(OPTIONAL)
PLASTER BOARD
CONNECT CABLEIN CEILING VOID
Ecolec LtdSharrocks StWolverhamptonWest MidlandsWV1 3RP01902 457 575www.ecolec.co.uk
THIS DRAWING IS THE SOLE PROPERTY OF ECOLECAND SHOULD NOT BE COPIED OR REPRODUCEDWITHOUT THE WRITTEN PERMISSION OF ECOLEC
NOTE. FOR ANTI-LIGATURE APPLICATIONSPECIAL FIXINGS AND APPLICATOR TOOLCAN BE SUPPLIED
A A
B B
C C
D D
E E
F F
G G
H H
J J
K K
L L
M M
16
16
15
15
14
14
13
13
12
12
11
11
10
10
9
9
8
8
7
7
6
6
5
5
4
4
3
3
2
2
1
1
DRAWN
CHK'D
APPV'D
MFG
Q.A
UNLESS OTHERWISE SPECIFIED:DIMENSIONS ARE IN MILLIMETERSSURFACE FINISH:TOLERANCES: LINEAR: ANGULAR:
FINISH: DEBURR AND BREAK SHARP EDGES
NAME SIGNATURE DATE
MATERIAL:
DO NOT SCALE DRAWING REVISION
TITLE:
DWG NO.
SCALE:1:5 SHEET 1 OF 1
A1
WEIGHT:
DEERFOLD 17.09.18
Ceiling Mounting_180917
CEILING MOUNTING OPTIONS
D
NOTES ON CEILING INSTALLATIONHEATER MUST BE SECURELY MOUNTEDIDEALLY INTO CEILING JOISTS
1000
500
1500
500
2000
500
PA
NEL
SIZ
E 4
4 F
IXIN
G
MULTIPLE SLOTS TO SECURE TO CEILING
C
HANGING WIRE SYSTEMUSED ON SUSPENDED CEILING TYPE PANEL
DETAIL C
SCALE 2 : 5
ECOLEC HEATER CASE FLUSH FIT DESIGNFOR SUSPENDED CEILING GRIDS
DETAIL D
SCALE 1 : 2.5
SCREW TO SUIT CEILINGCONSTRUCTION - NOM. No.5 x 40 LONG
PANEL HEATER
CEILING JOIST
NYLON SPACER(OPTIONAL)
PLASTER BOARD
CONNECT CABLEIN CEILING VOID
Ecolec LtdSharrocks StWolverhamptonWest MidlandsWV1 3RP01902 457 575www.ecolec.co.uk
THIS DRAWING IS THE SOLE PROPERTY OF ECOLECAND SHOULD NOT BE COPIED OR REPRODUCEDWITHOUT THE WRITTEN PERMISSION OF ECOLEC
NOTE. FOR ANTI-LIGATURE APPLICATIONSPECIAL FIXINGS AND APPLICATOR TOOLCAN BE SUPPLIED
A A
B B
C C
D D
E E
F F
G G
H H
J J
K K
L L
M M
16
16
15
15
14
14
13
13
12
12
11
11
10
10
9
9
8
8
7
7
6
6
5
5
4
4
3
3
2
2
1
1
DRAWN
CHK'D
APPV'D
MFG
Q.A
UNLESS OTHERWISE SPECIFIED:DIMENSIONS ARE IN MILLIMETERSSURFACE FINISH:TOLERANCES: LINEAR: ANGULAR:
FINISH: DEBURR AND BREAK SHARP EDGES
NAME SIGNATURE DATE
MATERIAL:
DO NOT SCALE DRAWING REVISION
TITLE:
DWG NO.
SCALE:1:5 SHEET 1 OF 1
A1
WEIGHT:
DEERFOLD 17.09.18
Ceiling Mounting_180917
CEILING MOUNTING OPTIONS
D
NOTES ON CEILING INSTALLATIONHEATER MUST BE SECURELY MOUNTEDIDEALLY INTO CEILING JOISTS
1000
500
1500
500
2000
500
PA
NEL
SIZ
E 4
4 F
IXIN
G
MULTIPLE SLOTS TO SECURE TO CEILING
C
HANGING WIRE SYSTEMUSED ON SUSPENDED CEILING TYPE PANEL
DETAIL C
SCALE 2 : 5
ECOLEC HEATER CASE FLUSH FIT DESIGNFOR SUSPENDED CEILING GRIDS
DETAIL D
SCALE 1 : 2.5
SCREW TO SUIT CEILINGCONSTRUCTION - NOM. No.5 x 40 LONG
PANEL HEATER
CEILING JOIST
NYLON SPACER(OPTIONAL)
PLASTER BOARD
CONNECT CABLEIN CEILING VOID
Ecolec LtdSharrocks StWolverhamptonWest MidlandsWV1 3RP01902 457 575www.ecolec.co.uk
THIS DRAWING IS THE SOLE PROPERTY OF ECOLECAND SHOULD NOT BE COPIED OR REPRODUCEDWITHOUT THE WRITTEN PERMISSION OF ECOLEC
NOTE. FOR ANTI-LIGATURE APPLICATIONSPECIAL FIXINGS AND APPLICATOR TOOLCAN BE SUPPLIED
A A
B B
C C
D D
E E
F F
G G
H H
J J
K K
L L
M M
16
16
15
15
14
14
13
13
12
12
11
11
10
10
9
9
8
8
7
7
6
6
5
5
4
4
3
3
2
2
1
1
DRAWN
CHK'D
APPV'D
MFG
Q.A
UNLESS OTHERWISE SPECIFIED:DIMENSIONS ARE IN MILLIMETERSSURFACE FINISH:TOLERANCES: LINEAR: ANGULAR:
FINISH: DEBURR AND BREAK SHARP EDGES
NAME SIGNATURE DATE
MATERIAL:
DO NOT SCALE DRAWING REVISION
TITLE:
DWG NO.
SCALE:1:5 SHEET 1 OF 1
A1
WEIGHT:
DEERFOLD 17.09.18
Ceiling Mounting_180917
CEILING MOUNTING OPTIONS
D
NOTES ON CEILING INSTALLATIONHEATER MUST BE SECURELY MOUNTEDIDEALLY INTO CEILING JOISTS
1000
500
1500
500
2000
500
PA
NEL
SIZ
E 4
4 F
IXIN
G
MULTIPLE SLOTS TO SECURE TO CEILING
C
HANGING WIRE SYSTEMUSED ON SUSPENDED CEILING TYPE PANEL
DETAIL C
SCALE 2 : 5
ECOLEC HEATER CASE FLUSH FIT DESIGNFOR SUSPENDED CEILING GRIDS
DETAIL D
SCALE 1 : 2.5
SCREW TO SUIT CEILINGCONSTRUCTION - NOM. No.5 x 40 LONG
PANEL HEATER
CEILING JOIST
NYLON SPACER(OPTIONAL)
PLASTER BOARD
CONNECT CABLEIN CEILING VOID
Ecolec LtdSharrocks StWolverhamptonWest MidlandsWV1 3RP01902 457 575www.ecolec.co.uk
THIS DRAWING IS THE SOLE PROPERTY OF ECOLECAND SHOULD NOT BE COPIED OR REPRODUCEDWITHOUT THE WRITTEN PERMISSION OF ECOLEC
NOTE. FOR ANTI-LIGATURE APPLICATIONSPECIAL FIXINGS AND APPLICATOR TOOLCAN BE SUPPLIED
A A
B B
C C
D D
E E
F F
G G
H H
J J
K K
L L
M M
16
16
15
15
14
14
13
13
12
12
11
11
10
10
9
9
8
8
7
7
6
6
5
5
4
4
3
3
2
2
1
1
DRAWN
CHK'D
APPV'D
MFG
Q.A
UNLESS OTHERWISE SPECIFIED:DIMENSIONS ARE IN MILLIMETERSSURFACE FINISH:TOLERANCES: LINEAR: ANGULAR:
FINISH: DEBURR AND BREAK SHARP EDGES
NAME SIGNATURE DATE
MATERIAL:
DO NOT SCALE DRAWING REVISION
TITLE:
DWG NO.
SCALE:1:5 SHEET 1 OF 1
A1
WEIGHT:
DEERFOLD 17.09.18
Ceiling Mounting_180917
CEILING MOUNTING OPTIONS
E
H
HANGING BY WIRES
DETAIL H SCALE 2 : 5
DISC HEAT™ CEILING SUSPENDED RADIANT PANEL SYSTEM
Showroom confi guration
ECO 250/CIR/RP/PC/RX ECO 250/CIR/RP/PC/RX
A
ECOLEC CONTROLLER1 OFF - 30M RANGE
SPECIFICATION:LINE REF CODE DIMENSIONS (H X W X D) MM ELEMENT (WATTS) OUTPUT (WATTS) OUTPUT (BTU’S)
Powder Coated White14.1 ECO 300/80/FF/RP/PC/RX 595 x 595 x 40 300 200 68214.3 ECO 750/80/FF/RP/PC/RX 1195 x 595 x 40 750 600 204714.4 ECO 1000/80/FF/RP/PC/RX 1785 x 595 x 40 1000 800 341214.5 ECO 1000/CE/RP/PC/RX 2000 x 500 x 40 1000 800 272914.6 ECO 750/CE/RP/PC/RX 1500 x 500 x 40 750 600 20473.9 Selected Powder Coated RAL COLOURS available for additional charge to Line Ref. 14.1 to 14.6
DISC HEAT CIRCLE Powder Coated White
14.16 ECO 250/CIR/RP/PC/RX 614mm Diameter 500 400 1365Powder Coated Black
14.17 ECO 250/CIR/RP/PCB/RX 614mm Diameter 500 400 1365Powder Coated Silver
14.18 ECO 250/CIR/RP/PCS/RX 614mm Diameter 500 400 1365ACCESSORIESPowder Coated White
14.20 Anti-Ligature Plate (x2 units) 950 x 10014.20 Rear Fixing Plate for Ceiling Joists (x2 Units)14.21 Ceiling Fixing Kit CE-01 4 x 0.6m each
Sharrocks Street, Wolverhampton WV1 3RP
Tel: 01902 457575 Fax: 01902 457797 Email: [email protected] Website: www.ecolec.co.uk
WIRELESS CONTROLLER (TRANSMITTER) KEY FEATURES:Keylock mode / Simple to Programme / Up to 6 temperature settings per day / 7 day clock / Advance mode / Economy mode / Holiday mode / Boost Mode / Inbuilt room temperature sensor / Frost protection / Powered by 2 x 1.5v Alkaline batteries
The TX control unit sends a 433MHz radio signal to each “registered” heater within a radius of 30 metres. Each RX panel heater has an inbuilt receiver designed to respond to a signal from the WCT 100/RX.
RADIATOR (RECEIVER) KEY FEATURES:Simply wire the heater to a fuse spur / Hidden wiring / No need to manually switch heaters “on” or “off”
7 day Inbuilt room
MK1 230V Mains KitBattery Kit WCT100, WCT500
NEW FEATURES!SURFACE TEMPERATURE SETTING:
WCT 500/TX/80
Press the two buttons as shown until current surface temperature is display. Then adjust to required temperature using the arrow buttons.
© Ecolec Ecolec 1995-2021. All rights reservedEcolec is a registered trademark of Ecolec LimitedAll specifications subject to change without notice
Proudly Manufactured in the UK.
Hereby, Ecolec Limited, declares that the radio equipment type thermostat and gateway are in compliance with Directive 2014/53/EU. The full text of the EU declaration of conformity is available at the following internet address:www.ecolec.co.uk/support E & O. E.
14.22 Adjustable Wall Brackets (Pair)