Upload
others
View
22
Download
0
Embed Size (px)
Citation preview
SPC ldquoDozardquo
3
SUCCEEDING TOGETHER IN RADIATION PROTECTION OF PEOPLE PROCESS AND ENVIRONMENT
Fast growing companyldquoDozardquo is one of the leading research and production companies specialized in design manufacture and supply of radiation monitoring solutions This is also one of the biggest developers of methodologies and software in Russian Federation and neighboring countries
Our company was founded in 1991 by a group of experts came from the Center of ionizing radiation ldquoVNIIFTRIrdquo based in Moscow region 20 years later our sales reached $42mln (2013) At least 5 of annual sales are re-invested in RampD
Our customers are essentially NPP fuel cycle companies National Nuclear authorities Emercom Ministry of Health Ministry of Defense Police Customs office National Transport organizations and Standard authorities research centers and laboratories Medical complexes Environmental organizations etc
Prior to supply our equipment to the end-users it passes thru a sophisticated test system and function analysis Most of our devices and equipment are supplied with the metering procedures which are adapted in compliance with the relevant normative documents After-sales service and maintenance are ensured by our service center We also organize trainings provide day-to-day customer service realize on-site servicing (assistance mounting installation commissioning maintenance) and make available a hot-line
Radiation detection and measurement solutions
ldquoDozardquo Scientific Production Company
Scientific Production Company ldquoDozardquo LtdSPC ldquoDozardquo Ltd
Georgievskiy prospekt 6 Zelenograd Moscow 124498 Russia
PO Box 50 Moscow 124460 Russia
Tel +7 495 777-84-85 +7 495 984-20-50
Fax +7 495 742-50-84 +7 499 734-02-56
E-mail infodozaru maildozagmailcom
wwwdozaru
SPC ldquoDozardquo
2 3
Manufacture and production capacitiesNew sophisticated machines and equipment ensure large production volume Own technology and highly skilled staff are key factors that allow us to guarantee a highest quality of suggested products
We use high technology laser metal sawing ma-chines powerful robotic processing equipment automated machine for board surface mount and some other Few years ago ldquoDozardquo built up new production building (1000 msup2) Now we have totally 2000 msup2 of production facilities and other 2000 msup2 are used for office and warehouse
Our product portfolioOur high scientific potential an extremely power-ful RampD and high adaptability to customer specs and markets needs allow us to supply reliable and cost-effective solutions which meet all requirements of domestic and international (IEC ISO) standards Our key product lines are portable dosimeters and radiometers spectrometers radiation monitoring system environmental surveillance stations critical accident alarm system medical equipment calibra-tion equipment Spare parts policy we commit to provide spare parts for our devices as soon as it is required by our customers
Business developmentWe are actually selling more than 200 different products in 20 countries We constantly increase our business volume in BRICS countries (Russia China India) and other newly developed regional powers We move fast forward in getting new accounts in Europe South America Asia and Middle East Our key target is to develop our business thru new partnership all over the world Any new partner is very welcome
ANRI magazine We have been releasing ldquoThe ANRI Journalrdquo (Radia-tion monitoring equipment and news) since 1994 We issue the most relevant research materials reports and articles dedicated to Health Physics radiation problematic methodology metrology and new equipment This Journal is referenced in Russian Federal Agency on Press and Mass Communication catalogue So ldquoThe ANRIrdquo is the exclusive periodical Russian journal focused on practical aspects of ra-diation monitoring It is also referenced in Chemical Abstracts
Quality management system ldquoDozardquo quality management system meets GOST ISO 9001-2011 requirements and is being a base of corporate management system Main company document that determines the principles of business doing operation and permanent improvement of the quality management system according to the principles and requirements of international stand-ards is the Quality Control Chart
Metrological service ldquoDozardquo has a quite developed metrological service based on the standards for dosimeters and radiom-eters calibration and verification pulse and static X-ray machines complying with ISO 4037 refer-ence X-ray dosimeter air flow volume calibration machine radioactive gases radiometer calibration standard gamma-sources Cs-137 Co-60 Co-57 Am-241 neutron Pu-Be sources alpha- and beta-sources and spectrometric sources Our metrological service is one of the best equipped laboratories in Russia It is accredited in performing primary and periodical verification and calibration More than 30000 verifi-cations per year are done in our lab
Our staff Over 200 people including 12 PhD and 85 engineers represent the most valuable capital of ldquoDozardquo
Seven employees of our company were awarded for their participation in elimination of the Chernobyl accident consequences Our experts participate in development and implementation of normative and methodological documents which make the basis of radiation safety in Russia
Among our specialists there are experts of bull Scientific and Technical Board of the State Atomic
Energy Corporation ldquoRosatomrdquo bull Technical committee 45 IEC ldquoNuclear instrumen-
tationrdquo bull Technical committee of 413 Rosstandart bull Coordination Council of the ldquoRosatomrdquo on the
development of the environmental radiation monitoring system (ERMS)
bull Working group of the ldquoRosatomrdquo on developing the ldquoIntegrated complex safety management system in the field of Nuclear Powerrdquo
bull Association of Medical Physicists of Russia (AMPR)
4
Training Since 1994 ldquoDozardquo has been organizing different types of training Best specialists from national and international research centers come to ldquoDozardquo We provide our trainees with up-to-date methodological and standard norms documents In order to create an independent educational entity in 2007 ldquoDozaldquo founded Educational and Methodological Center ldquoMonitoring and Safetyrdquo This Center is functioning under the License of the Moscow Department of Education
Few references20 NPP use our equipment More than 1000 med-ical institutions are our customers The biggest Ice-breaker in the world is equipped with our RMS Within 2013-2014 we have successfully supplied 450 measuring channels to the bigger Mining and Chemical Complex
Radiation Monitoring
System
Radiation monitoring system SPC ldquoDozardquo
6 7
More than 100 Radiation Monitoring Systems ldquoPelikanrdquo are installed and operating successfully at facilities representing different industries including research reactors nuclear power plants and the icebreaker ldquo50 Years of Victoryrdquo
FeaturesThe RMS ldquoPelikanrdquo constitutes a complex of independent units (intended for measurement of different parameters) that are interconnected into common information network The RMS network
is built using Ethernet IEEE 8023 technology it accommodates measurement devices and workstations as clients The network includes two servers (main and hot standby) or alternatively it can have no server at all The RMS allows performing all commutations necessary for repair or calibration of measurement units in hot mode without interrupting normal network operation
ldquoPELIKANrdquoRADIATION MONITORING SYSTEM (RMS)
Major users of ldquoPelikanrdquo RMS system are Nuclear Power Plants in Russia Ukraine China and India as well as Rosatom Rospotrebnadzor Ministry of Emergency Situations Rosstandard Ministry of Health Ministry of Defense Russian Railways laboratories and other companies and organizations
bull GMP ldquoZvesdochkardquo Severodvinskbull Mining and Chemical Complex Zheleznogorskbull Institute of Physics and Power Engineering
Obninskbull Russian Research Institute of Technical Physics
Sarov
REFERENCE
bull Leningrad NPPbull laquoAtomflotraquobull ldquoZvesdardquo factory Bolrsquoshoy Kamenrsquobull Petersburg Nuclear Physics Institutebull Civil Security Department Moscowbull ldquoRosatomrdquo Corporation MosNPO ldquoRadonrdquobull ldquoRosatomrdquo Corporation ldquoSNIIP-Systematomrdquobull ldquoRosenergoatomrdquo Concern Moscowbull Norilsk Mining and Smelting producerbull Russian Research Institute ldquoVNII Avtomatikardquo
Moscowbull Kudankulam NPP Indiabull Tianwan NPP China
Radiation monitoring system SPC ldquoDozardquo
8 9
SKGAV Stack monitor
UPPVM Air flow parameters monitor
RM Rack
UDG-1B Noble gas monitor
UDGB-01Noble gasesH-3C-14
monitor
UDA-1AB Particulate monitor
UDI-1BIodine monitor
UDGP-01 Steam generator leakage
monitor
RMSworkstation
Ethernet switch
Ethe
rnet
RS
-485
RMS workstationServer
DBG-S11D Wide range gamma area monitor
BDMG-101 High range gamma area monitor
UDMN-100 Neutron area monitor
BDRG-52 High range gamma area monitor
BASBAS-1s External alarm
BOP-1M Data processing and
transmission unit
RADIATION MONITORING SYSTEM
Ethe
rnet
RS
-485
BI-2 Remote display amp alarm unit
ldquoImpulsrdquoExternal Display Unit
UDKG-100 Wel Liquid gamma monitor
Ethernet RS-485 Ethernet RS-485
UDG-03D Noble gas monitor
UDGP-01 Liquidtechnological environment monitor
Radiation monitoring system SPC ldquoDozardquo
10 11
bull Continuous automatic monitoring of the ambient dose equivalent rate
bull Нigh temperature range (up to 120 degC)
BDMG-101 HIGH RANGE GAMMA AREA MONITOR
Physical characteristicsbull detector ndash ionization chambers
Measurement rangebull MIC-1 5∙10-5 divide 200 Svhbull MIC-2 5∙10-4 divide 1000 Svhbull MIC-3 1∙10-5 divide 100 Gyhbull MIC-4 5∙10-3 divide 10000 Gyh
Energy rangebull 005 divide 30 MeV
temperature rangebull ionization chamber module MIC-1
minus 30 divide +120 degCbull electrometric module MIC-2 MIC-3 MIC-4 ME
minus 30 divide +60 degC
Electrical characteristicsbull interfaces RS-485bull cable length between MIC and ME up to 30 m
Mechanical characteristicsbull Protection index IP 65
Overall dimensions weightbull ME Oslash105times293 mm 23 kgbull MIC-1 Oslash85times206 mm 12 kgbull MIC-2 Oslash45times156 mm 03 kgbull MIC-3 Oslash136times226 mm 09 kgbull MIC-4 Oslash35times92 mm 02 kg
BOP-1M
Reference standards Nuclear IEC 60846 IEC 60532
DBG-S11D WIDE RANGE GAMMA AREA MONITOR
Continuous automatic monitoring of the ambient dose equivalent rate
Physical characteristicsbull Detector ndash GM counters
Measurement rangebull DBG-S11D 01 μSvh divide 10 mSvhbull DBG-S11D-01 01 μSvh divide 10 Svhbull DBG-S11D-02 01 μSvh divide 100 Svh
Energy rangebull 005 divide 30 MeV
Temperature range bull minus 40 divide +50 ordmC
Electrical characteristicsbull Interfaces RS-485 USB
Mechanical characteristicsbull Protection index IP 68bull Paint decontaminable
Overall dimensions weightbull DBG-S11D Oslash 68times141 mm 065 kg bull DBG-S11D-01 Oslash 68times179 mm 07 kgbull DBG-S11D-02 Oslash 68times179 mm 07 kg
Versionsbull DBG-S11Dbull DBG-S11D-01bull DBG-S11D-02
BOP-1M
Reference standards Nuclear IEC 60532
Versionsbull stainless steel 100 cm2 ionization chamber
module (MIC-1) and electrometric module (ME)bull stainless steel 20 cm2 ionization chamber module
(MIC-2) and electrometric module (ME)bull duralumin 500 cm2 ionization chamber module
(MIC-3) and electrometric module (ME)bull titanium 2 cm2 ionization chamber module
(MIC-4) and electrometric module (ME)
Radiation monitoring system SPC ldquoDozardquo
12 13Reference standards EMC IEC 61010 IEC 61000-6-2 Seismic IEC 60980
bull Continuous automatic monitoring of the ab-sorbed dose rate
bull Monitoring inside containmentbull Delivery assembled detector and communication
linebull Communication line include inter wall protective
tubebull Hermetic communication line filled dry nitrogen
Physical characteristicsbull detector - stainless steel ionization chamber
Measurement range bull 10-3 divide 105 Gyh
Energy range bull 006 divide 30 MeV
Temperature range bull detector
0 divide 207 ordmC continuous
250 ordmC during 1 hour bull electrometric module 0 divide +60 ordmC
Detector operating pressure bull 07 МPa
Electrical characteristicsbull Interfaces RS-485bull detector-electrometric module cable length up
to 70 m
BDRG-52 HIGH RANGE GAMMA AREA MONITOR FOR ACCIDENT AND POST-ACCIDENT CONDITIONS
Ionization chamber
Mechanical characteristicsProtection index bull detector - IP 65bull electrometric module - IP 23bull Paint stainless steel
Overall dimensions weight bull detecting unit Oslash50х220 mm 3 kgbull inter wall protective tube Oslash 159 length (by order)
1200 ndash 1600 mm 60 kgbull electrometric module 420x420x120 mm 8 kg
Reference standards Nuclear IEC 60951 EMC IEC 61010 IEC 61000-6-2 Seismic IEC 60980
Continuous monitoring of technological environ-ments liquid couples sludges etc bull On line gamma spectrometry
Physical characteristicsbull Detector ndash scintillator CsI NaI
Measurement range bull Gamma-activity 10bull104 divide 20bull108 Bqm3
Energy range bull gamma 005 divide 15 MeV
Temperature range bull minus 10 divide +80 ordmС
UDGP-01 LIQUID TECHNOLOGICAL ENVIRONMENTS MONITOR
Electrical characteristicsbull Interfaces RS-232 RS-485 Ethernetbull programmable relay output (SPDT relay)
Mechanical characteristicsbull Protection index IP 65bull Paint decontaminable
Overall dimensions weight bull Detector unit
CsIOslash 60x360 mm17 kg NaIOslash 35x750 mm26 kg
bull Data processing and transmission unit BOP-1sp 280x220x114mm 43 kg
Alarmbull Sound alarm 80 divide 100 dBA at distance 1 mbull Visual alarm green yellow redbull Connection of the external alarm unit of ldquoBASrdquo
type
Radiation monitoring system SPC ldquoDozardquo
14 15
BOP-1M DATA PROCESSING AND TRANSMISSION UNIT
bull Processing of data incoming from detecting blocks UDMN-100 DBG-S11D UDKG-100 BDMG-101 BDRG-52
bull Data transmission to the network bull Data transmission to the mobile computer bull Storage of thresholds values and parameters of
detecting blocksbull Power supply and diagnostics of detecting blocks bull Generation of the alarm signals of the excess of
preset thresholdsbull Data backup in the non-volatile memory
Physical characteristicsbull Quantity of joined detecting blocks and alarm
units ndash up to 20bull Temperature range minus 40 divide +50 ordmC
Electrical characteristicsbull Power supply 85 divide 260 V 47 divide 440 Hzbull Interfaces RS-232 RS-485 Ethernet bull programmable relay output (SPDT relay)
Mechanical characteristicsbull Protection index IP 65 bull Paint decontaminable
Overall dimensions weightbull 298times220times114 mm 5 kg
Reference standards EMC IEC 61010 IEC 61000-6-2 Seismic IEC 60980
Continuous automatic monitoring of the neutron-radiations ambient dose equivalent ratebull Spherical polyethylene moderator Oslash 239 mm
UDMN-100 NEUTRON AREA MONITOR
Physical characteristicsbull detector ndash scintillator ZnS(Ag) Li-6
Measurement range bull 01 μSvh divide 01 Svh
Energy range bull 0025 eV divide 100 MeV
Temperature range bull minus 45 divide +50 ordmC
Electrical characteristicsbull Interfaces RS-485
Reference standards Nuclear IEC 61005 IEC 61322 EMC IEC 61010 IEC 61000-6-2 Seismic IEC 60980
UDKG-100WEL LIQUID GAMMA MONITOR
Mechanical characteristicsbull Protection index IP 65bull Paint decontaminable
Overall dimensions weight bull 428times258times347 mm 115 kg
Continuous automatic monitoring of the gamma radiation flux Operation in the rocks ore liquid media and sludge
Physical characteristics bull detector ndash NaI (Tl) Oslash 18x30 mm
Measurement range bull 40 divide 8104 s-1cm-2
Energy range bull 01divide 30 MeV
Temperature rangebull minus 40 divide +50 degC
Electrical characteristics bull Interfaces RS-485
Mechanical characteristics bull Protection index
Ř BDKG-100 IP 68 Ř Interface block BS-16 IP 65
bull Paint stainless steel bull Overall dimensions weight
Ř Detector unit BDKG-100 Oslash 38times530 mm 3 kg Ř Interface block BS-16 176times80times64 07 kg
Radiation monitoring system SPC ldquoDozardquo
16 17
UDG-1B NOBLE GAS MONITOR
Continuous automatic monitoring of the beta-emit-ting radioactive gases concentration in the working air and in the air in ventilation ducts and stacksbull Gamma background compensation bull Audible and visual alarm signals of the excess of
preset thresholds bull Periodic calibration by means of standard beta-
source
Physical characteristicsbull Silicon detectors (2 pcs for measurement and for
background compensation)bull Air flow rate 10 divide 100 lminbull Operation temperature range minus 10 divide +50 ordmС
Measurement range bull 104 divide 6109 Bqm3
Energy range bull 008 divide 30 MeV
Electrical characteristicsbull Power supply 85 divide 260 V 47 divide 440 Hzbull Interfaces RS-232 2timesRS-485 Ethernetbull programmable relay output (SPDT relay)bull Analog output 4-20 mA (optional)
Mechanical characteristicsbull Protection index IP 65bull Paint decontaminable
Overall dimensions weight bull Stationary version 395times240times304 mm 295 kgbull Mobile version with pump unit BN-1
395times468times950 mm 543 kg
Alarmbull Sound alarm 80 divide 100 dBA at distance 1 mbull Visual alarm green yellow red
Mobile version with pump unit BN-1
Stationary version
Reference standards Nuclear IEC 60761 IEC 62302 EMC IEC 61010 IEC 61000-6-2 Seismic IEC 60980
bull Connection of the external alarm unit ldquoBASrdquo type
Versionsbull Stationary versionbull Stationary version with pump unit BN-1bull Mobile version with pump unit BN-1
UDA-1AB PARTICULATE MONITOR
Stationary version
Continuous automatic monitoring of the alpha- and beta- radioactive aerosol concentration in the work-ing air and in the air in ventilation ducts and stacksbull Radon toron progenies and gamma background
compensation bull On line alpha spectrometrybull Audible and visual alarm signals of the excess of
preset thresholds bull Control of electromagnetic valves when operating
with the external air sampling linebull Control of pump unit bull Periodic calibration by means of standard beta-
and alpha-sources
Physical characteristicsbull Silicon specrometric detectors (2 pcs for measure-
ment and for background compensation)bull Filter tape types LFAS FSLWbull Tape consumption (when continuous operation)
10 m50 daysbull Air flow rate 10 divide 100 lmin bull Operation temperature range minus 10 divide +50 ordmС
Measurement range bull Alpha 10-2 divide 2105 Bqm3 bull Beta 10-1 divide 106 Bqm3
Energy range bull Alpha 30 divide 90 MeV bull Beta 005 divide 30 MeV
Electrical characteristicsbull Power supply 85 divide 260 V 47 divide 440 Hzbull Interfaces RS-232 2timesRS-485 Ethernet bull Programmable relay output (SPDT relay)bull Analog output 4-20 mA (optional)
Mechanical characteristicsbull Protection index IP 65bull Paint decontaminable
Overall dimensions weight bull Stationary version 389times260times304 mm 156 kg bull Mobile version with pump unit BN-1
389times468times950 mm 384 kg
Alarmbull Sound alarm 80 divide 100 dBA at distance 1 mbull Visual alarm green yellow redbull Connection of the external alarm unit ldquoBASrdquo type
Versionsbull Stationary versionbull Stationary version with pump unit BN-1bull Mobile version with pump unit BN-1
Reference standards Nuclear IEC 60761 IEC 61172 EMC IEC 61010 IEC 61000-6-2 Seismic IEC 60980
Mobile version with pump unit BN-1
Radiation monitoring system SPC ldquoDozardquo
18 19
Physical characteristicsbull Scintillation detectors CsI(Tl) (2 pcs for measure-
ment and for background compensation)bull Cartridge activated charcoal
Measurement range bull 37 divide 37106 Bqm3
Energy range bull 006 divide 30 MeVbull Air flow rate 20 divide 40 lminbull Operation temperature range minus 10 divide +50 ordmС
Electrical characteristicsbull Power supply 85 divide 260 V 47 divide 440 Hzbull Interfaces RS-232 2timesRS-485 Ethernetbull Programmable relay output (SPDT relay)bull Analog output 4-20 mA (optional)
Mechanical characteristicsbull Protection index IP 65bull Paint decontaminable
Overall dimensions weight bull Stationary version 448times323times479 mm 35 kgbull Mobile version with pump unit BN-1
448times468times950 mm 578 kg
Reference standards Nuclear IEC 60761 IEC 61171 EMC IEC 61010 IEC 61000-6-2 Seismic IEC 60980
Alarmbull Sound alarm 80 divide 100 dBA at distance 1 mbull Visual alarm green yellow redbull Connection of the external alarm unit of ldquoBASrdquo
type
Versionsbull Stationary versionbull Stationary version with pump unit BN-1bull Mobile version with pump unit BN-1
Сontinuous automatic monitoring radioiodine concentration in the air at working places and in ventilation ducts and stacksbull Measurement of volumetric activity of radionu-
clides I-131 I-132 I-133 I-135 in the airbull On line gamma spectrometrybull Gamma background compensation bull Performance self-test by means of Am-241 check
source implanted into the detectorbull Audible and visual alarm signals of the excess of
preset thresholdsbull Periodic calibration by means of standard source
UDI-1B IODINE MONITOR
Physical characteristicsbull Silicon detector 2 pcs (for measurement and for
background rejection)bull Air flow rate 10 divide 100 lminbull Operation temperature range minus 10 divide +50 ordmС
Measurement range bull 104 divide 11010 Bqm3
Energy rangebull 006 divide 30 MeV
Electrical characteristicsbull Power supply 120 Vbull Interface RS-485
Mechanical characteristicsbull Protection index IP 65bull Paint decontaminable
Overall dimensions weight bull 474х246х243 mm 295 kg
UDG-03D NOBLE GAS MONITOR
Measurement of volumetric activity of beta-emitting radioactive gases (argon krypton xenon) adapted to the measurement of the rapidly changing volume activity in various technological processesbull Gamma background compensationbull Periodic calibration by means of standard beta-
source
Reference standards Nuclear IEC 60761 IEC 62302 EMC IEC 61010 IEC 61000-6-2 Seismic IEC 60980
Radiation monitoring system SPC ldquoDozardquo
20 21
Continuous automatic monitoring of steam genera-tor primary to secondary leakagebull On line gamma spectrometrybull N-16 monitoringbull Performance self-test by means of Am-241 check
source implanted into the detectorbull Audible and visual alarm signals of the excess of
preset thresholds
Physical characteristics
UDGP-01 STEAM GENERATOR LEAKAGE MONITOR
bull detector ndash scintillator CsI Oslash 40х100 mm
Measurement range bull High energy gamma-activity (N-16)
15bull103 divide 20bull108 Bqm3
bull General gamma-activity 10bull104 divide 20bull108 Bqm3
Energy range bull General gamma 005 divide 15 MeV bull in integral spectral band of energy
5000 divide 7200 keV bull temperature range minus 10 divide +80 ordmС
BOP-1SP
Electrical characteristicsbull Power supply 85 divide 260 V 47 divide 440 Hzbull Interfaces RS-232 RS-485 Ethernetbull programmable relay output (SPDT relay)
Mechanical characteristicsbull Protection index IP 65bull Paint decontaminable
Overall dimensions weight bull Detector unit Oslash 60x360 mm17 kgbull Data processing and transmission unit BOP-1sp
280x220x114mm 43 kgbull Collimator Oslash 350x455 mm 150 kg
Alarmbull Sound alarm 80 divide 100 dBA at distance 1 mbull Visual alarm green yellow redbull Connection of the external alarm unit of ldquoBASrdquo
type
Reference standards Nuclear IEC 61453 EMC IEC 61010 IEC 61000-6-2 Seismic IEC 60980Reference standards Nuclear IEC 60761 IEC 60710 IEC 60951-2 EMC IEC 61010 IEC 61000-6-2 Seismic IEC 60980
Ionization chambe 10 liters
UDGB-01T1
Physical characteristicsbull Detectors - stainless steel ionization chambersbull Air flow rate 10 divide 100 lminbull Operation temperature range minus 10 divide +50 ordmС
Volumes of ionization chambers bull UDGB-01T UDGB - 01T1 100 litersbull UDGB-01T2 01 liter
Measurement range (Kr-85) bull UDGB-01T UDGB-01T1 10104 divide 50109 Bqm3
bull UDGB-01T2 109 divide 501014 Bqm3
Measurement range (H-3) bull UDGB-01T UDGB-01T1 50104 divide 50109 Bqm3
bull UDGB-01T2 50109 divide 501014 Bqm3
Electrical characteristicsbull Power supply 85 divide 260 V 47 divide 440 Hzbull Interfaces RS-232 2timesRS-485 Ethernetbull Programmable relay output (SPDT relay)bull Analog output 4-20 mA (optional)
Mechanical characteristicsbull Protection index IP 23bull Paint decontaminable
Continuous automatic monitoring of the beta-emitting radioactive gases including tritium and carbon-14 concentration in the air at working places and in ventilation ducts and stacksbull Audible and visual alarm signals of the excess of
preset thresholds bull Monitoring of the noble gase activity in gaseous
effluents and ventilation air for accident and post-accident conditions
Overall dimensions weight bull UDGB-01T 381times343times716 mm 30 kgbull UDGB-01T1 260times320times175 mm 125 kgbull Ionization chamber 100 liters Oslash 250times600 mm
6 kgbull UDGB - 01T2 381times343times716 mm 27 kg
Alarmbull Sound alarm 80 divide 100 dBA at distance 1 mbull Visual alarm green yellow redbull Connection of the external alarm unit ldquoBASrdquo type
Versionsbull UDGB-01T - with built-in ionization chamber
100 litersbull UDGB-01T2 - with built-in ionization chamber
01 literbull UDGB-01T1 - with remote ionization chamber
100 liters
UDGB-01NOBLE GASESH-3C-14 MONITOR
Radiation monitoring system SPC ldquoDozardquo
22 23
Physical characteristicsLength of communication cablebull up to 1200 m
Character height bull ldquoImpuls-910-Rrdquo 100 mmbull ldquoImpuls-915-D4Srdquo 150 mmbull ldquoImpuls-927-D4Srdquo 270 mm
Operating temperature rangebull ldquoImpuls-910-Rrdquo 0 divide +50 ordmCbull ldquoImpuls-915-D4Srdquo ldquo-927-D4Srdquo minus 40 divide +50 ordmC
Electrical characteristicsbull Power supply 220 V 50 Hz
Mechanical characteristicsProtection index bull ldquoImpuls-910-R IP 44bull ldquoImpuls -915-D4Srdquo ldquo-927-D4Srdquo IP 65
Overall dimensions weight bull ldquoImpuls-910-Rrdquo 400times160times60 mm 3 kgbull ldquoImpuls -915-D4Srdquo 815times250times80 mm 5 kgbull ldquoImpuls -927-D4Srdquo 1250times330times80 mm 5 kg
ldquoIMPULSrdquoEXTERNAL DISPLAY UNIT
Display of data received from monitors of RMS
External display unit ldquoImpuls-910-Rrdquo
Reference standards EMC IEC 61010 IEC 61000-6-2 Seismic IEC 60980
Continuous monitoring of the flow rate temperature and humidity of the gas flowbull Definition of air volume flow rate in stacks taking
into account temperature and humidity of the air
UPPVM AIR FLOW PARAMETERS MONITOR
Physical characteristicsMeasurement range bull air flow velocity 1 divide 20 msbull air temperature 0 divide +80 ordmСbull air humidity 10 divide 95
Electrical characteristicsbull Power supply 220 V 50 Hz bull Interfaces RS-232 Ethernet
Mechanical characteristicsProtection index bull BSPP-1st BSPP-1tv BOP-1s IP 65bull PP-st IPTV IP 54bull Paint decontaminable
Overall dimensions weight bull air velocity probe PP-st 60times38times136 mm 015 kgbull Interface block BSPP-1st 125times155times73 mm 07 kgbull air temperature and relative humidity probe
IPTV-056-A 333times100times60 mm 07 kgbull Interface block BSPP-1tv 125times155times73 mm 07 kgbull Data processing and transmission unit BOP-1s
280x233x111 mm 8 kg
Reference standards Nuclear ISO 2889 EMC IEC 61010 IEC 61000-6-2 Seismic IEC 60980
BOP-1S
Radiation monitoring system SPC ldquoDozardquo
24 25
BASBAS-1S EXTERNAL ALARM
Generation of audible and visual signals of the excess of preset thresholds RMS monitorsbull Audible alarm 80 divide 100 dBA at distance 1 mbull Visual alarm green yellow red
Distance from RMS monitorbull BAS up to 20 mbull BAS-1s up to 1200 m
Power supply bull 220 V 50 Hz
Overall dimensions weight bull BAS 145times108times460 mm 18 kg bull BAS-1s 166times109times466 mm 18 kg
Reference standards EMC IEC 61010 IEC 61000-6-2 Seismic IEC 60980
Physical characteristicsLength of communication cablebull up to 1200 m
Displayed page size bull 4 lines of 20 characters
Volume of loaded information bull 10 pages
Change of pagesbull programmed or by pressing a button
Operating temperature rangebull minus 40 divide +50 ordmC
Electrical characteristicsbull Power supply 9 divide 18 VDCbull Interfaces RS-485
Mechanical characteristicsbull Protection index IP 65bull Overall dimensions weight 222times164times73 mm
40 kg
BI-2 REMOTE DISPLAY amp ALARM UNIT
bull Display of data received from monitors of RMSbull Audible and visual alarms on exceeding preset
thresholds of the RMS equipment bull Individual threshold setting for each measure-
ment channelbull Audible alarm 80 divide 100 dB at a distance of 1 m bull Visual alarm red yellow green
Reference standards EMC IEC 61010 IEC 61000-6-2 Seismic IEC 60980
Radiation monitoring system SPC ldquoDozardquo
2726
Electrical characteristicsbull Power supply 220 V 50 Hz bull Interfaces RS-232 RS-485 Ethernetbull programmable relay output (SPDT relay)
Alarmbull Sound alarm 80 divide 100 dBA at distance 1 mbull Visual alarm green yellow redbull Connection of the external alarm unit ldquoBASrdquo type
Related monitors and equipmentsbull UDA-1AB particulate monitorbull UDG-1B noble gas monitorbull UDI-1B iodine monitorbull UPPVM air flow parameters monitorbull Sampling and sample separation rack
Air flow parameters monitor rack
Reference standards Nuclear IEC 60761 IEC 61171 IEC 61172 IEC 62302 ISO 2889 EMC IEC 61010 IEC 61000-6-2 Seismic IEC 60980
Sampling and sample separation rack
Continuous monitoring of radioactivity in gaseous effluentsbull Automatic monitoring of the alpha- and beta-
radioactive aerosol noble gas and radioiodine concentrations in the air in ventilation ducts and stacks
bull Monitoring of the flow rate temperature and humidity of the gas flow
bull Separation of gaseous effluent into targeted fractions by means of a two-stage filter
bull Reversion of gas after analysis to the ventilation system
Physical characteristics
Particulate (UDA-1AB)bull Silicon specrometric detectors (2 pcs for measure-
ment and for gamma-background compensation) bull Filter tape types LFAS FSLWbull Tape consumption (when continuous operation)
10 m50 days
Measurement range bull Alpha 10-2 divide 2105 Bqm3 bull Beta 10-1 divide 106 Bqm3
Energy range bull Alpha 30 divide 90 MeV bull Beta 005 divide 30 MeV
Noble gas (UDG-1B)bull silicon detectors (2 pcs for measurement and for
gamma-background compensation)
Measurement range bull 104 divide 6109 Bqm3
Energy range bull 008 divide 30 MeV
Iodine (UDI-1B)bull scintillation detectors CsI(Tl) (2 pcs for measure-
ment and for background compensation)
SKGAV STACK MONITOR
Particulate noble gas and iodine monitors rack
Measurement range bull 37 divide 37105 Bqm3
Energy range bull 015 divide 30 MeV
Air flow parameters (UPPVM)Measurement range bull air flow velocity 1 divide 20 msbull air temperature 0 divide +80 ordmСbull air humidity 10 divide 95
Radiation monitoring system SPC ldquoDozardquo
28 29
CONFIGURATOR SOFTWAREMaintenance and set-up softwarebull Set-up and verify RMS monitorsbull Control testing adjustment and repair of RMS
monitorsbull Monitors measurement results archive receive
and View bull Communication through RS-232
RMS WORKSTATION ndash OPERATOR CONSOLEOrganization of interaction of the RMS Server and Monitors
Single monitor console includes vandal-proof key-board amp UPS
Reference standard IEC 61559-1 IEC 61559-2
RMS SOFTWAREData acquisition storing and visual representation RMS monitors measurement resultsbull Ethernet IEEE 8023 networkbull Clientserver architecturebull TCPIP protocolbull Oracle based Data Basebull Supremal by means InSat MasterSCADA
Radiation monitoring system SPC ldquoDozardquo
30 31
Delivery setComposition and modification depend on the tasks to be solved using the RM Rack
The rack which is an integral part of RM Rack accommodatesbull Monitors UDA-1AB UDG-1B UDG-03D UDI-1B
UDGB-01Tbull DBG-S11D Wide range gamma area monitor
BDMG-101 High range gamma area monitor UDMN-100 Neutron area monitor BDRG-52R High range gamma area monitor
bull BI-2 Remote display amp alarm unitbull Pump unit BN-01bull Data processing and transmission unit BOP-1Mbull External alarm BAS or BAS-1sbull Equipment of sampling line (flow meters ball
valves filter holder piping solenoid valve)bull Switchboard (intended for switching of all equip-
ment and transfer of data to the upper level via the unified communication channel)
RM RACK RADIATION MONITORING RACK
The radiation monitoring rack (RM Rack) is designed for continuous monitoring of radiation parameters in premises and technological systems at nuclear facil-ities RM Rack can be used as a structural element of the lower-level of RMS at nuclear power plants and other nuclear facilities that involved in obtaining processing use and storage of radioactive materials
FeaturesContinuous automatic monitoring of the alpha- and beta- radioactive aerosol beta-emitting radioactive gases and radioiodine concentrations in the working air and in the air in stacks and others radiation parameters in the facilities
The stand providesbull Primary processing storage and transmission of
measured and related data into the information channel based on the Ethernet IEEE 8023 inter-face (TCPIP protocol)
bull Transfer of required data to the location where the equipment is installed via technological channels based on RS-232 interface
bull Generation of audible and visual warning alarm signals when the preset thresholds are exceeded
bull Display of received data on the LCD
Radiation monitoring system SPC ldquoDozardquo
32 33Reference standards IEC 60860 ANSIANS-83 ISO 7753
Purposebull Detection and recording of criticality accident
(CA) by measuring the absorbed dose rate of gamma-neutron radiation in the premises of monitored object its comparison with a threshold value and generation of audible and visual signals
bull Automatic collection processing storage and display of measurement data and related infor-mation as visual and graphical representation for operators of nuclear safety service
Functions of the systembull Detection and recording of CA events by con-
tinuous measurement of absorbed dose rate of gamma radiation comparison of measured values with preset thresholds generation of signals to activate the alarm
bull Activation of audible visual alarmbull In the event of CA turning on warning signals
ldquoDO NOT ENTERrdquo at illuminated information pan-els placed at the entrances to the controlled area
Featuresbull Data can be transferred to external data commu-
nication channel using RS-485 interface (DiBus data exchange protocol)
bull Automatic self-testing of detection units BR-04D with display of information about the type of fault
bull Possibility for connecting additional a detection and alarm units
bull Ability to function in general regardless of the functioning of components within the agreed scope of nuclear safety tasks
bull Radiation hardness up to 100 Gy
SRKS-01DCRITICALITY ACCIDENT ALARM SYSTEM
Features of softwarebull Collection of information via RS-485 network
displaying it on the PC monitor transmission to remote users archiving and storage
bull Status monitoring and display of values measured by BR-04D and DBG-S11D in locations as per layout of premises
bull Access to archived data with possibility to gener-ate reports for periods determined by operator
bull Maintenance and archiving of a log of dosimetric measurements data and events along with their time stamps
bull Possibility to transfer data to external users via Ethernet network for integrating of CA into higher level systems
Basic complete setLower level bull Control unit with power supplybull BR-04D detection unitsbull BZS-01D audible alarm unitsbull BSS-01D visual alarm unitsbull SIT-01D illuminated warning signsbull PBZ panels for muting audible alarmbull Network communication module
Additional lower layer devicesbull DBG-S11D wide range gamma area monitor
Upper layer bull CDP central display panelbull Service workstation
RS-485
RS-485
RS-4
85
Audible alarm units BZS-01D
Illuminated warning signs SIT-01D
Detection units BR-04D
Network communication
moduleDBG-S11D wide range gamma area monitor
Panels for muting audible alarm
Control unit with power supply
Visual alarm units BSS-01D
RS-485
RS-485
RS-4
85
Audible alarm units BZS-01D
Illuminated warning signs SIT-01D
Detection units BR-04D
Network communication
moduleDBG-S11D wide range gamma area monitor
Panels for muting audible alarm
Control unit with pow-er supply
Visual alarm units BSS-01D
RS-485
RS-4
85
Audible alarm units BZS-01D
Illuminated warning signs SIT-01D
Detection units BR-04D
Network communication
moduleDBG-S11D wide range gamma area monitor
Panels for muting audible alarm
Control unit with power supply
Visual alarm units BSS-01D
RS-485
RS-485
RS-4
85
Audible alarm units BZS-01D
Illuminated warning signs SIT-01D
Detection units BR-04D
Network communication
moduleDBG-S11D wide range gamma area monitor
Panels for muting audible alarm
Control unit with power supply
Visual alarm units BSS-01D
Ethernet
Central display panel Service workstation
RS-485
RS-485
RS-4
85
BZS-01D audible alarm units
SIT-01D illuminated warning signs
BR-04D detection units
Network communication
moduleDBG-S11D wide range gamma area monitor
PBZ panels for muting audible alarm
Control unit with power supply
BSS-01D visual alarm units
Radiation monitoring system SPC ldquoDozardquo
34 35
ldquoBREEZErdquoHIGH-VOLUME AIR SAMPLER
Physical characteristicsbull Measurement range of air flow rate
250 divide 1200 m3hbull Continuous operation time not less than 24 h
Filter materialsbull High-purity glass fiberbull Pure quartz or cellulosebull Filter fabric FPP-15-15
Electrical characteristicsPower supply bull 220380 V 50 Hz
Interfaces bull RS-485bull Ethernetbull GSMGPRS (option)
Environmental characteristicsTemperature range bull minus 40 divide + 40 ordmC
Relative humidity limit at 35 ordmC bull 95
Atmospheric pressure range bull 840 divide 1067 kPa
Versionsbull Standalone unit bull Part of Environmental Radiation Monitoring
System (ERMS)
Type of detection unitsbull Beta block BDZB-100Lbull DBG-S11D wide range gamma area monitorbull Scintillation spectrometric block
The motor of Air Sampler is controlled by an electronic flow sensor that detects changes in the operators pre-set flow rate caused by changes in temperature barometric pressure and pressure drop due to dust loading on filter media It compensates for these changes by adjusting the motor speed to maintain the pre-set flow ratebull Measurement of parameters of ionizing radiation bull Standalone mode of operation or as the part
of Environmental Radiation Monitoring System (ERMS)
Purposebull Environmental Radiation Monitoring System
(ERMS) in the control and buffer areas of the radia-tion and nuclear facilities
Referencesbull Since the year 2000 the system is successfully
operating the ERMSs at 8 Russian nuclear power plants (about 180 monitoring stations)
bull Since the year 2005 the ERMS is operating in the Moscow (about 40 monitoring stations)
bull Since the year 2005 the regional ERMS is under operation in several Russian Federation regions
Basic complete setMonitoring stations bull Data processing and transmission unit BOP-1TA bull Gamma area monitor DBG-S11D
Central data processing station (CDPS)bull Data processing and transmission unit BOP-1TAbull Server
By requestbull Emergency Response and Crisis Management
Centers for enterprisesbull Regional Emergency Response and Crisis Manage-
ment Centersbull rdquoBreezerdquo High-Volume Air Samplerbull Mobile lab with gamma-survey system rdquoGammandash
sensorrdquo
ldquoATLANT-MrdquoENVIRONMENTAL RADIATION MONITORING SYSTEM
Monitoring system for the continuous radiation monitoring of territories and facilities with the data transmission GSMGPRS network
Data transmission bull GSMGPRS
Power supply bull 220 V 50 Hz
Continuous autonomous operation (at 20 ordmC)bull From built-in battery not less than 5 hoursbull From external battery not less than 24 hours
Operation temperature bull Minus 40 divide +50 ordmC
Operation humidity bull Up to 98
Protection bull IP65
Reference standards Nuclear IEC 61017-11991 IEC 61017-21994
36
Radiation Monitoring Equipment
bull Localization of radioactive contaminationsbull Database with dose rate contaminations
spectra measurement date amp time coordi-nates
bull Work as part of mobile laboratory or as part of Environmental Radiation Monitoring System with real-time data transfer
Physical characteristicsDetector bull Scintillation NaI (Tl) GM counters
Measurement rangebull 01 ndash 107 μSvh
Energy range bull 005 ndash 3 MeV
Operation temperature range bull minus 10 divide +50 ordmС
Electrical characteristics bull Power supply 220 V 50 Hz
ldquoGAMMAndashSENSORrdquoGAMMA-SURVEY SYSTEM
SPC ldquoDozardquoRadiation monitoring equipment
38 39
AREA MONITOR ldquoFREGATrdquoArea Monitor ldquoFregatrdquo is designed for building rela-tively simple and inexpensive radiation monitoring systems at such facilities as radionuclide sources storage areas isotope products warehouses nuclear medicine departments PET centers calibration laboratories where sources of ionizing radiation are used etc
Small scale automated radiation monitoring systems built with ldquoFregatrdquo components featuring audible and visual alarms are matched suitable to meet the regulatory radiation safety requirements
Area monitor ldquoFregatrdquo requires virtually no adjust-ment it is simple and convenient for installation and operation
BPI-1D LOCAL DISPLAY UNIT
Display of monitored parameters values received from external measuring devices
Purposebull Processing and display of values of monitored
parameters on information panel bull Comparison of values of monitored parameters
with thresholdsbull Transfer of monitored parametersrsquo values to
networkbull Generation of alarm in case of exceeding of preset
thresholds including external alarm devices
FeaturesTesting the unit and connected devicesbull Visually on the panelbull Using adjustment software when connected to
PC via USB
Automatic self-testing
The panel displays the following informationbull Diagnostic information about the status of con-
nected devicesbull Current date and timebull Values of measured parametersbull Position of measured values with respect to the
thresholds in the form of scales with green yellow and red zones
bull Time history (trend) for each measured value
Physical characteristicsTemperature range bull minus 10 divide + 50 ordmC
Maximum number of connected devicesbull measuring devices 15bull external audible and visual alarm 15
Display diagonal bull 152 cm (6)
Electrical characteristicsbull Interfaces RS-485bull Power supply 220 V 50 Hz 12 divide 24 V
Mechanical characteristicsbull Protection index IP54bull Paint decontaminable
Overall dimensions weightbull 296x248x118 mm 5 kg
DBG-S11D wide range gamma area monitor
UDMN-100 neutron area monitor
Ethernet RS-485
UDKS-100 gamma and X-ray area monitor
BPI-1D Local display unit
BAS-2 ldquoMicrordquo external visual alarm
BZS-2 ldquoMicrordquo external audible alarm
ldquoImpulsrdquo external display unit
Service workstation
Illuminated warning signs
SPC ldquoDozardquoRadiation monitoring equipment
4140
Continuous automatic monitoring of the gamma- X-ray ambient dose equivalent rate
Physical characteristicsbull Detector tissue-equivalent plastic scintillator
Oslash 45times20 mm
Measurement range bull Dose rate measurement range 01 μSvh divide 1 Svh bull Energy range 0015 divide 10 MeV
Mechanical characteristicsbull Protection index IP65bull Paint decontaminable
Overall dimensions weightbull Oslash72times265 mm 15 kg
UDKS-100 GAMMA AND X-RAY AREA MONITOR
UDMN-100 NEUTRON AREA MONITOR
Physical characteristicsbull detector ndash scintillator ZnS(Ag) Li-6
Measurement range bull 01 μSvh divide 01 Svh
Energy range bull 0025 eV divide 100 MeV
Temperature range bull minus 45 divide +50 ordmC
Electrical characteristicsbull Interfaces RS-485
Mechanical characteristicsbull Protection index IP 65bull Paint decontaminable
Overall dimensions weight bull 428times258times347 mm 115 kg
Continuous automatic monitoring of the neutron-radiations ambient dose equivalent ratebull Spherical polyethylene moderator Oslash 239 mm
MEASURING UNITS
DBG-S11D WIDE RANGE GAMMA AREA MONITOR
Continuous automatic monitoring of the gamma- ambient dose equivalent rate
Physical characteristicsbull Detector ndash GM counters
Measurement rangebull DBG-S11D 01 μSvh divide 10 mSvhbull DBG-S11D-01 01 μSvh divide 10 Svhbull DBG-S11D-02 01 μSvh divide 100 Svh
Energy rangebull 005 divide 30 MeV
Temperature range bull minus 40 divide +50 ordmC
Electrical characteristicsbull Interfaces RS-485 USB
Mechanical characteristicsbull Protection index IP 68bull Paint decontaminable
Overall dimensions weightbull DBG-S11D Oslash 68times141 mm 065 kg bull DBG-S11D-01 Oslash 68times179 mm 07 kgbull DBG-S11D-02 Oslash 68times179 mm 07 kg
Versionsbull DBG-S11Dbull DBG-S11D-01bull DBG-S11D-02
Reference standards Nuclear IEC 60846 IEC 60532 EMC IEC 61010 IEC 61000-6-2 Seismic IEC 60980
SPC ldquoDozardquoRadiation monitoring equipment
4342
ALARM UNITS
Generation visual signals of the excess of preset thresholds
Physical characteristicsLength of communication cablebull up to 1200 mbull Alarm Visual alarm green yellow red
Electrical characteristicsbull Power supply +12 V
Mechanical characteristicsbull Protection index IP 23
Overall dimensions weight 160times84times41 mm 02 kg
BAS-2 ldquoMICROrdquo EXTERNAL VISUAL ALARM
Generation audible signals of the excess of preset thresholds
Physical characteristicsLength of communication cablebull up to 1200 mbull Audible alarm 80 divide 100 dB at a distance of 1 m
Electrical characteristicsbull Power supply +12 V
Mechanical characteristicsbull Protection index IP 23
Overall dimensions weight 160times84times41 mm 02 kg
BZS-2 ldquoMICROrdquo EXTERNAL AUDIBLE ALARM
Physical characteristicsLength of communication cablebull up to 1200 m
Electrical characteristicsbull Power supply 220 V 50 Hz
Mechanical characteristicsbull Protection index IP 23
Overall dimensions weight bull 330times110times20 mm 05 kg
Physical characteristicsLength of communication cablebull up to 1200 m
Character height bull ldquoImpuls-910-Rrdquo 100 mmbull ldquoImpuls-915-D4Srdquo 150 mmbull ldquoImpuls-927-D4Srdquo 270 mm
Operating temperature rangebull ldquoImpuls-910-Rrdquo 0 divide +50 degCbull ldquoImpuls-915-D4Srdquo ldquo-727-D4Srdquo minus 40 divide +50 degC
Electrical characteristicsbull Power supply 220 V 50 Hz
Mechanical characteristicsProtection index bull ldquoImpuls-910-R IP 44bull ldquoImpuls-915-D4Srdquo ldquo-727-D4Srdquo IP 65
Overall dimensions weight bull ldquoImpuls-910-Rrdquo 400times160times60 mm 3 kgbull ldquoImpuls-915-D4Srdquo 815times250times80 mm 5 kgbull ldquoImpuls-927-D4Srdquo 1250times330times80 mm 5 kg
ILLUMINATED WARNING SIGNS
ldquoIMPULSrdquo EXTERNAL DISPLAY UNIT
SPC ldquoDozardquoRadiation monitoring equipment
4544
Individual threshold setting for each measurement channel
Continuous area and process monitoring
Collect amp display data from two measurement chan-nels (units with RS-485 or analog pulses)
Audible and visual alarms on exceeding preset thresholds or status of connected devices
Individual threshold setting for each measurement channel
Switching on the external alarm or executive devices when any threshold is exceeded
The wide panel displays the following information bull Values of measured parameters as min-1∙cm-2
s-1∙cm-2 μSvhbull Diagnostic information about the status of con-
nected devicesbull Current date and timebull Position of measured values with respect to the
thresholds in the form of scales with green yellow and red zones
bull Time history (trend) for each measured value
Physical characteristics Measurement range bull Count rate up to 107 CPM (170 kHz)
Operating temperature range bull minus 20 divide +50 ordmC
Electrical characteristics bull Power supply 220 V bull Interfaces USB
Mechanical characteristics bull Protection index IP 65 bull Overall dimensions weight 222times164times73 mm
40 kg
UIM-3D AREA MONITOR COUNT RATE METER
Measurement of alpha radiation flux density
Detector unit BDZA-100 (70 cm2) Measurement range 01 divide 104 min-1∙cm-2
Detector unit BDZA-100B (300 cm2) Measurement range 01 divide 2103 min-1∙cm-2
Measurement of beta radiation flux density
Detector unit BDZB-100 (28 cm2) Measurement range 10 divide 105 min-1∙cm-2
Detector unit BDZB-100L (30 cm2) Measurement range 10 divide 104 min-1∙cm-2
Detector unit BDZB-11D (84 cm2) Measurement range 5 divide 15∙104 min-1∙m-2
OPTIONAL PROBESMeasurement of gamma radiation flux density
Detector units BDEG-03 Measurement range 4 divide 2000 s-1∙cm-2
Detector unit UDKG-100 for operation in the rocks ore liquid media and sludge Measurement range 40 divide 8000 s-1∙cm-2
Measurement of the ambient dose equivalent rate
Detector unit DBG-S11D Measurement range 01 μSvh divide 100 Svh
Measurement of neutron radiation ambient dose equivalent rate
Detector unit BDMN-100 Measurement range 01 μSvh divide 01 Svh
SPC ldquoDozardquoRadiation monitoring equipment
46 47Reference standards Nuclear IEC 61526
Measurement of gamma-radiation personal dose equivalent Hp(10)bull Stand-alone dosimeter or composed of dosimetric
system onebull Audible and visual alarmbull Large memory dose accumulation historiesbull Exclusion of unauthorized intervention in dosim-
etry operation
DKG-05D PERSONAL GAMMA DOSIMETER
Physical characteristicsDetectors bull Silicon
Measurement range bull Dose rate 1 μSvh divide 10 Svhbull Dose 01 μSv divide 15 Sv
Energy range bull 005 divide 30 MeV
Electrical characteristicsbull Power supply rechargeable NiMH battery 1
alcaline battery (type AAA)
Operation timebull Till recharging not less 400 hoursbull With one set batteries not less 1000 hours
Mechanical characteristicsOverall dimensions weight bull 47times26times87 mm (with clip) 70 g
Environmental characteristicsbull IP65bull Temperature range minus 20 divide +45 ordmCbull Humidity up to 98 at 35 ordmCbull Shock vibration and drop resistant
Alarmbull Excess of alarm thresholdsbull Warnings of self-test failure and battery discharge bull Audible alarm 80 dB at 40 cmbull Visual alarm blinking LED
Relative equipmentbull One dosimeter charger ZU-1Mbull Chargestorage cassetes KZU-28KZU-56bull ldquoSmart chargingrdquo feature extends battery life timebull DKG-05D reader US-05bull DKG-05D system reader DVS-01D
Reader-PC interfacebull US-05 USB bull DVS-01D Ethernet
KZU-28
Physical characteristicsDetectors bull Silicon Li-6
Gamma measurement range bull Dose rate 1 μSvh divide 10 Svhbull Dose 01 μSv divide 15 Sv
Gamma energy range bull 005 divide 60 MeV
Neutron measurement range bull Dose rate 1 μSvh divide 2 Svhbull Dose 20 μSv divide 15 Sv
Neutron energy range bull 0025 eV divide 20 MeV
Electrical characteristicsPower supply bull Rechargeable NiMH batterybull Operatiion time till recharging not less 200 hours
Mechanical characteristicsOverall dimensions weight bull 47times26times87 mm (with clip) 70 g
Environmental characteristicsbull IP65bull Temperature range minus 20 divide +40 ordmCbull Humidity up to 75 at 30 ordmCbull Shock vibration and drop resistant
Alarmbull Excess of alarm thresholds bull Warnings of self-test failure and battery discharge bull Audible alarm 80 dB at 40 cmbull Visual alarm blinking LED
Relative equipmentbull One dosimeter charger ZU-1Mbull Chargestorage cassetes KZU-28 KZU-56bull ldquoSmart chargingrdquo feature extends battery life timebull DVS-02D reader UZS-01Sbull DVS-02D system reader DVS-01D
Reader-PC interfacebull UZS-01S USB bull DVS-01D Ethernet
UZS-01DReference standards Nuclear IEC 61526
DVS-02D GAMMA-NEUTRON PERSONAL ELECTRONIC DOSIMETER
Measurement of gamma- and neutron radiations personal dose equivalent Hp(10)bull Stand-alone dosimeter or composed of dosimetric
system onebull Audible and visual alarmbull Large memory dose accumulation historiesbull Exclusion of unauthorized intervention in dosim-
etry operationbull Both albedo thermal neutrons and intermediate
fast neutrons registrationbull Usable in the fields of Pu(Be) Po(Be) Cf and other
neutron sources as well as near nuclear reactors without neutron spectrum estimation
SPC ldquoDozardquoRadiation monitoring equipment
48 49
Dosimeters DVG-03D
DVGI-8D NEW PEN-TYPE PERSONAL IONIZATION CHAMBER DOSIMETERS
Measurement of personal dose equivalent Hp(10) of gamma and X-ray radiationbull Hp(10) of continuous and pulsed gamma and
X-ray radiation bull Electronic reader KSU-1bull Dosimeter DVG-03D with electronic ID bull Personal dose histories in the readerrsquos memorybull Readerrsquos connection with PC for database main-
tenance
Physical characteristicsDetector bull Ionization chamber
Measurement range bull 001 mSv divide 25 mSv
Energy range bull 0015 divide 25 MeV
Temperature range bull Reader KSU-1 +10 divide +50 ordmСbull Dosimeter DVG-03D minus 40 divide +50 ordmС
Electrical characteristicsPower supply bull Reader KSU-1 220 V 50 Hz built-in batteries bull Dosimeter DVG-03D four batteries CR 1025 bull Batteries life 3 yearsbull Readers interfaces RS-232USB 20
Mechanical characteristicsOverall dimensions weightbull Dosimeter DVG-03D Oslash 18times126 mm 005 kgbull Reader KSU-1 235times232times125 mm 28 kg
Reference standards Nuclear IEC 62387-1
DKG-02U ldquoARBITERrdquo WIDE RANGE GAMMA-DOSIMETER
Physical characteristicsDetectors bull GM counters
Measurement rangebull Dose-rate 01 μSvh divide 3 Svhbull Dose 1 μSv divide 100 Sv
Energy range bull 005 divide 3 MeV
Electrical characteristicsbull Power supply 2 alcaline batteries (type AA)bull Batteries life not less 200 hours
Mechanical characteristicsOverall dimensions weight bull 152times82times32 mm 03 kg
Environmental characteristicsbull Temperature range minus 20 divide +50 ordmCbull Humidity up to 90 at +25 ordmCbull Shock vibration and drop resistant
Reference standards Nuclear IEC 60846
Measurement of gamma radiation ambient equiva-lent dose H(10) and dose rate H(10)bull Audible signals (clicks) for radiation condition
estimationbull Analog scale for search modebull Audible and visual alarms of the excess of preset
dose and dose rate thresholds bull Shock-resistant water-proof easy decontamina-
tion casebull 100 measurement results memory with date and
time of measurementbull Indication of total dose accumulated during
exploitation time bull Indication of measurement result statistical
uncertainty
SPC ldquoDozardquoRadiation monitoring equipment
50 51
Physical characteristicsDetectors bull GM counter
Measurement rangebull Dose-rate 01 μSvh divide 3 mSvhbull Dose 1 μSv divide 02 Sv
Energy range bull 005 divide 3 MeV
Temperature range bull Minus 20 divide +50 ordmC
Electrical characteristicsbull Power supply 2 alcaline batteries 15 V (type AA)bull Batteries life not less 200 hours
Mechanical characteristicsOverall dimensions weight bull 122times74times29 mm 025 kg
Reference standards Nuclear IEC 60846
DKG-07D ldquoDROZDrdquoGAMMA-DOSIMETER
Measurement of gamma radiation ambient equiva-lent dose H(10) and dose rate H(10)bull Two independent measurement channels dose
and dose ratebull Audible signals (clicks) for radiation condition
estimationbull Continuous measurement with updating meas-
urement resultbull Measurement result can be obtained with any
desired statistical uncertainty (error)bull Automatic restart when radiation level sharply
changesbull Indication of statistical uncertainty (error) during
measurement process
Continuous measurement with updating measure-ment result
Automatic restart when radiation level sharply changes bull Gamma dose H(10) and dose-rate H(10) meas-
urementbull Beta and gamma contamination surveybull Indication of statistical uncertainty during the
measurementbull Continuous measurement with accuracy increas-
ing with time bull Automatic restart triggered by change of gamma
dose-ratebull Compensation of gamma count rate while meas-
uring beta radiationbull Indication of battery charge levelbull Audible signal of the excess of preset threshold
Physical characteristicsDetectors bull GM counter
Measurement range bull Dose-rate 01 microSvh divide 20 mSvhbull Dose 1 microSv divide 100 Svbull Beta flux density (for Sr-90+Y-90)
10 divide 105 cm-2 min-1
Energy range bull Gamma 005 divide 3 MeVbull Beta 01 divide 3 MeV
Temperature range bull Minus 20 divide +50 ordmC
MKS-15D ldquoSnegirrdquo backside
MKS-15D ldquoSNEGIRrdquoMULTI ndash PURPOSE RADIATION SURVEY METER
Reference standards Nuclear IEC 60846 IEC 60325
Electrical characteristicsbull Power supply 2 alcaline batteries (type AA)bull Battery life not less 400 hours
Mechanical characteristicsOverall dimensions weight bull 124times72times35 mm 035 kg
SPC ldquoDozardquoRadiation monitoring equipment
52 53
Physical characteristicsDetectorbull GM counter
Measurement range bull 01 μSvh divide 20 mSvh
Energy range bull 005 divide 30 MeV
Threshold setting range bull 03 μSvh divide 20 mSvh
Step change of the thresholdbull In the range 03 divide 10 μSvh with the step
001 μSvhbull In the range 10 divide 100 μSvh with the step
01 μSvhbull In the range 100 divide 2000 μSvh with the step
10 μSvh
Electrical characteristicsPower supply bull 220 V 50 Hz bull Relay output
Mechanical characteristicsProtection index bull IP 40
Overall dimensions weight bull 226times120times75 mm 07 kg
Alarmbull Sound alarm 80 divide 100 dBA at distance 1 mbull Visual alarm redbull Connection of the external alarm signaling unit
Reference standards Nuclear IEC 60846 IEC 60532
Continuous automatic monitoring of the ambient dose equivalent rate bull Measurement of gamma dose rate H(10)bull Audible and visual alarm signals for preset
thresholdsbull Switching on the external signaling or executive
devices
SRPS-05D GAMMA MONITOR
Measurement ofbull Gamma and X-ray personal dose equivalent
Hp(10)bull Neutron personal dose equivalent Hp(10)bull Lens dose equivalent Hp(3)bull Skin dose equivalent Hp(007)bull TLD reader day-to-day tests using built-in LEDbull No needs nitrogen for heating
Physical charachteristicsDetectors bull 7LiF Mg Ti (gamma beta)bull 6LiF Mg Ti (neutron)
Gamma and X-ray Hp(10) Measurement range bull 500 μSv divide 10 Sv
Energy range bull 0015 divide 30 MeV
Neutron Hp(10)Measurement range bull 01 mSv divide 100 mSv
Energy range bull 0025 eV divide 10 MeV
Beta and photons Hp(007) Hp(3) Measurement range bull 2 mSv divide 100 Sv
Energy range bull Beta 025 divide 35 MeVbull Photons lt15 keV
Mechanical characteristicsDosimeters overall dimensions weight bull Gamma Hp(10) DTL-2 holder - 62times26times16 mm
16 gbull DTU holder - 42times28times18 mm 8 gbull Lens Hp(3) face skin Hp(007) Oslash 32times16 mm 9 gbull Finger skin Hp(007) 90times20times2 mm 1 gbull Neutron gamma Hp(10) 48times40times20 mm 30 g
Reference standards Nuclear IEC 61066
DTL-2 DTU-2
MKD (A-type) DVNG-M
DOZA-TLD MULTIPURPOSE TLD SYSTEM
SPC ldquoDozardquoRadiation monitoring equipment
54 55
Continuous and pulsed gamma and X-ray dose H(10) and dose-rate measurementbull Alpha beta and gamma contamination surveybull Neutron dose H(10) and dose-rate measurementbull Gamma radiation flux density in boreholes and
liquid media measurement
Electrical characteristicsPower supply bull UIK-05 four C-size batteriesbull UIK-05-01 rechargeable batterybull UIK-06 rechargeable battery
Interfaces bull RS-232bull USB (via adapter)
bull Detector type automatic determination and corre-sponding measurement modes selection
bull Alarm threshold settings ndash for dose dose-rate alpha and beta contaminations
bull ldquoDetectrdquo and ldquoLocaterdquo modes for survey probes
Reference standards Nuclear IEC 60846 IEC 60325 IEC 61005 IEC 62363
Case
UIK-06 control unit165times78times48 mm 03 kg
DKS-96UNIVERSAL RADIATION SURVEY METER
UIK-05 control unit202times86times90 mm 10 kg
BDZA-96
BDZA-96B
BDZA-96M
BDZA-96S
BDZA-96T
EXTERNAL PROBES ALPHAALPHA BDZA-96Detector bull ZnS(Ag) 70 cm2
Measurement range (for Pu-239)bull 01 divide 104 min-1cm-2
Overall dimensions weightbull Oslash 130times240 mm 11 kg
ALPHA BDZA-96BDetector bull ZnS(Ag) 300 сm2
Measurement range (for Pu-239)bull 01 divide 2103 min-1cm-2
Overall dimensions weightbull Oslash 230times290 mm 40 kg
ALPHA BDZA-96MDetector bull ZnS(Ag) 10 сm2
Measurement range (for Pu-239)bull 01 divide 105 min-1cm-2
Overall dimensions weightbull Oslash 65times240 mm 09 kg
ALPHA BDZA-96SDetector bull ZnS(Ag) 30 сm2
Measurement range (for Pu-239)bull 01 divide 5104 min-1cm-2
Overall dimensions weightbull Oslash 90times240 mm 10 kg
ALPHA BDZA-96TDetector bull Silicon 5 сm2
Measurement range (for Pu-239)bull 01 divide 106 min-1cm-2
Overall dimensions weightbull Oslash 50times60 mm 015 kg
SPC ldquoDozardquoRadiation monitoring equipment
56 57
BETA BDZB-96Detector Scintillator 28 сm2
Measurement range (for Sr-90+Y-90)bull 10 divide 105 min-1cm-2
Energy rangebull 03 divide 30 MeV
Overall dimensions weightbull Oslash 90times230 mm 09 kg
BETA BDZB-99Detector bull GM counter 30 сm2
Measurement range (for Sr-90+Y-90)bull 20 divide 104 min-1см-2
Energy rangebull 012 divide 30 MeV
Overall dimensions weightbull Oslash 88times80 mm 04 kgbull Telescopic pole length 07 m
BETA BDZB-96BDetector bull GM counter 80 сm2
Measurement range (for Sr-90+Y-90)bull 3 divide 104 min-1сm-2
Energy rangebull 012 divide 30 MeV
Overall dimensions weightbull 150times200times110 mm 15 kg
BETA BDZB-96Sbull Detector GM counter 15 сm2
Measurement range (for Sr-90+Y-90)bull 10 divide 3104 min-1cm-2
Energy rangebull 012 divide 30 MeV
Overall dimensions weightbull Oslash 65times65 mm 03 kgbull Telescopic pole length 07 m
BDZB-96
BDZB-99
BDZB-96B
BDZB-96S
EXTERNAL PROBES BETA
GAMMA BDKS-96BDetector bull Tissue-equivalent scintillator Oslash 45times20 mm
Measurement rangebull Dose rate H(10) 01 μSvh divide 1 Svhbull Dose H(10) 01 μSv divide 10 Sv
Energy rangebull 0015 divide 10 MeV
Overall dimensions weightbull Oslash 60times250 mm 085 kg
GAMMA AND BETA BDKS-96SDetector bull Double GM counters
Measurement rangebull Gamma dose rate H(10) 01 μSvh divide 1 mSvhbull Gamma dose H(10) 01 μSv divide 10 Svbull Beta 10 divide 3104 min-1cm-2
Energy rangebull Gamma 005 divide 3 MeVbull Beta 012 divide 3 MeV
Overall dimensions weightbull Oslash 80times80 mm 035 kgbull Telescopic pole length 07 m
GAMMA BDMG-96Detector bull GM counters
Measurement rangebull Dose rate H(10) 01 μSvh divide 10 Svhbull Dose H(10) 01 μSv divide 10 Sv
Energy range bull 005 divide 3 MeV
Overall dimensions weightbull 40times250 mm 05 kgbull Telescopic pole length 07 m 4 m (by request)
EXTERNAL PROBES GAMMA
BDKS-96B
BDMG-96
BDKS-96S
SPC ldquoDozardquoRadiation monitoring equipment
58 59
GAMMA-SEARCH BDVG-96Detector bull Scintillator NaI(Tl) Oslash 63times63 mm
Measurement rangebull Flux density measurement range 4 divide 2000 s-1cm-2
bull Dose rate H(10) for Cs-137 01 divide 30 μSvhbull Sensitivity for Cs-137 3000 (pulsess-1)( μSvh-1)
Overall dimensions weightbull Oslash 88times400 mm 20 kgbull Modular pole length 16 m
GAMMA-SEARCH BDPG-96Detector bull Scintillator NaI(Tl) Oslash 25times40 mm
Measurement rangebull Flux density measurement range 10 divide 8000 s-1cm-2
bull Dose rate H(10) for Cs-137 01 divide 100 μSvhbull Sensitivity for Cs-137 500 (pulsess-1)( μSvh-1)
Overall dimensions weightbull 50times190times480 mm 10 kgbull Telescopic pole length 07 m
GAMMA-SEARCH BDPG-96MDetector bull Scintillator NaI(Tl) Oslash 18times30 mm
Measurement rangebull Flux density measurement range 10 divide 24000 s-1cm-2
bull Dose rate H(10) for Cs-137 01 divide 300 μSvhbull Sensitivity for Cs-137 200 (pulsess-1)( μSvh-1)
Overall dimensions weightbull Oslash 35times320 mm 05 kgbull Telescopic pole length 07 or 38 m
EXTERNAL PROBES GAMMA
BDVG-96
BDPG-96M
BDPG-96
EXTERNAL PROBESGAMMA BDKG-96 STAINLESS STEEL CASING FOR GEOLOGIC APPLICATIONS WELL LOGGINGDetector bull Scintillator NaI(Tl) Oslash 18times30 mm
Measurement rangebull Flux density measurement range 10 divide 105 s-1cm-2
bull Dose rate H(10) for Cs-137 5 divide 2104 μRhbull Sensitivity for Cs-137 200 (pulsess-1)( μSvh-1)
Overall dimensions weightbull Oslash 38times535 mm 36 kgbull Cable length 10 divide 1000 m
NEUTRON BDMN-96Detector bull Scintillator with ZnS(Ag)
Measurement rangebull Dose rate H(10) 01 μSvh divide 01 Svhbull Dose H(10) 01 μSv divide 10 Sv
Energy range bull 0025 eV divide 10 MeV
Overall dimensions weightbull Detector Oslash 54times200 mm 08 kgbull Moderator Oslash 245 mm 73 kg
NEUTRON-SEARCH BDKN-96Detector bull He-3 counter in polyethilene moderator
Measurement rangebull Dose rate H(10) for Pu-Be 01 μSvh divide 01 Svhbull Dose H(10) for Pu-Be 01 μSv divide 10 Sv
Energy range bull 0025 eV divide 14 MeV
Overall dimensions weightbull 295times142times100 mm 225 kg
BDKG-96M
BDMN-96
BDKN-96
SPC ldquoDozardquoRadiation monitoring equipment
60 61
bull No gas supply neededbull Clothing control detachable right hand detector bull Alpha detector optional connection bull Numeric and color (red green) indication of
control resultsbull LED sensor of hand-foot positioning for start of
measurementbull Automatic compensation of gamma background
and contamination of detectorbull Audible alarm signals of the excess of preset
thresholdsbull Measurement value indication min-1cm-2 or
Bqсm2
Reference standards Nuclear IEC 61098
RZB-05D HAND-FOOT-CLOTHING MONITOR
Physical characteristicsDetectors bull Gamma beta - GM countersbull Alpha - scintillatior ZnS(Ag)
Detecting nuclidesbull Alpha Pu-239 U-234 U-238bull Beta Sr-90+Y-90 F-18 Cs-137 Co-60 Tс-99 O-15
N-13 Sr-89 C-11 I-131 Na-22 Ru-106+Rh-106 Tl-204
bull Gamma Tc-99m I-123
Efficiencybull Alpha
Pu-239 40 U-234 25U-238 15
bull Beta Sr-90 +Y-90 40
Measurement range bull Alpha 1 divide 103 min-1cm-2 bull Beta 10 divide 103 min-1cm-2
bull Gamma 5103 divide 5106 min-1cm-2
Energy range bull Alpha 30 divide 80 MeV bull Beta 008 divide 35 MeV bull Gamma 005 divide 30 MeV
Operation temperature range bull Minus 10 divide +50 ordmС
Electrical characteristicsbull Power supply 220 V 50 Hz
Mechanical characteristicsOverall dimensions weight bull 740times750times1180 mm 45 kg
Versionsbull Withwithout alpha detectorbull Indication (min-1cm-2 ) or (Bqсm2)bull Detectors overall dimensions smbull Hand 178 х 235bull Foot 185 х 436
Whole body contamination monitor RZBA-04-04Mbull No gas supply neededbull Compensation for background gamma radiation
and contamination of detector unitsbull Individual threshold setting for each measure-
ment channelbull Visible and audible alarms ldquoCONTAMINATIONrdquo and
ldquoCLEANrdquo bull Indication of contaminated body parts on the
panel with image of the bodybull Optional remote alpha-detector
Physical characteristicsDetectors bull Beta - GM counters scintillatorsbull Alpha - scintillatior ZnS(Ag)
Measurement range bull Beta 5 divide 15000 min-1cm-2
bull Alpha 01 divide 10000 min-1cm-2
Energy range bull Beta 015 divide 25 MeV bull Alpha 40 divide 56 MeV
Operation temperature range bull +5 divide +50 ordmС
Electrical characteristicsPower supply bull 220 V 50 Hz
Interfaces bull RS-232bull RS-485
Mechanical characteristicsOverall dimensions weight bull 2650times940times930 mm 310 kg
Versionsbull Withwithout alpha detectorbull Indication (min-1cm-2 ) or (Bqсm2)
Reference standards Nuclear IEC 61098
RZBA-04-04MWHOLE BODY CONTAMINATION MONITOR
SPC ldquoDozardquoRadiation monitoring equipment
62 63
RZA-05DALPHA HAND-MONITOR
bull No gas supply needed bull Numeric and color (red green) indication of
control resultsbull LED sensor of hand- positioning for start of
measurementbull Audible alarm signals of the excess of preset
thresholdsbull Measurement value indication min-1cm-2 or
Bqсm2
Physical characteristicsDetectors alpha - scintillatior ZnS(Ag)
Efficiencybull Pu-239 20 bull U-234 14bull U-238 8
Measurement range bull 05 divide 105 min-1cm-2
Energy range bull 41 divide 90 MeV
Operation temperature range bull minus 10 divide +50 ordmС
Electrical characteristicsPower supply bull 220 V 50 Hz
Mechanical characteristicsOverall dimensions weight no more bull 740times1400times1450 mm 70 kg
Reference standards Nuclear IEC 61098
bull Simultaneous measurement of alphabeta activi-ties in the sample
bull Active shielding anti-coincidence background subtraction using GM counters
bull Lead shielding 30 mm
UMF-2000 LOW LEVEL ALPHA- BETA- COUNTER
Physical characteristicsDetectors bull Silicon specrometric detector 500 or 1000 mm2
Measurement range bull Alpha 001 divide 1000 Bq bull Beta 01 divide 3000 Bq
Energy range bull Alpha 35 divide 80 MeV bull Beta 005 divide 35 MeV
Electrical characteristicsPower supply bull 220 V 50 Hz
Interfaces bull RS-232bull USB
Mechanical characteristicsOverall dimensions weight bull 337times286times190 mm 22 kg
Versionsbull Detector area 500 mm2
bull Detector area 1000 mm2
UMF-2000 Detector area 1000 mm2
UMF-2000 Detector area 500 mm2
SpectraDec software for alpha-spectrometric measurements
SPC ldquoDozardquoRadiation monitoring equipment
64 65
DRK DOSE AREA PRODUCT METER
DRK-1bull Diagnostic reference level (DRL) of patients
determinationbull Suitable for all basic types of x-ray machines
Physical characteristicsDetector bull Plane-parallel ionization chamber
Measurement range bull 1 divide 104 cGycm2
Electrical characteristicsPower supply bull 220 V 50 Hz
DRK-1M-CTbull Measuring of dose length product
Physical characteristicsDetector bull Pencil Ionization Chamber
Measurement rangebull 05 divide 109 microGym
DRK-1Mbull Measuring of air kerma on sectional area of the
X-ray beam productbull Measuring of air kerma rate on area productbull Measuring of air kerma ratebull Measuring of air kerma
Physical characteristicsDetector bull Plane-parallel ionization chamber
Measurement rangebull 01 divide 109 microGym2
bull 06 divide 6104 microGym2cbull 30 divide 9105 microGycbull 30 divide 9991011 microGyReference standard IEC 60580 2003
bull Measurement of strontium-90 in the foodstuffs agricultural products etc
bull Measurement of gross beta activity in samplebull Self tests using built-in LED
ldquoPROGRESS-BETArdquo SCINTILLATION BETA SPECTROMETER
Physical characteristicsDetector bull Plastic scintillator Oslash70x10 mm
Sample bull Plate Oslash70 mmbull Weight up to 15 g
Energy range bull 02 divide 30 MeV
Minimum detectable activity of Sr-90 in a 10 g sample on a standard planchet Bqsamplebull In case of absence of K-40 in the sample 01 Bqbull In case the activity of K-40 till 5 Bqg 05 Bq
Electrical characteristics Interface bull USB
Mechanical characteristicsWeight bull No more 50 kg
Complete setBasic complete setbull Detector unit with plastic scintillator integrated
power supply amplifier ADC bull Lead shielding bull ldquoProgressrdquo software bull Сheck source for energetic calibration (Sr-90-Y-90) bull Planchet Oslash 70 mm (5 items) bull Sample dencification device bull Procedure manual for measurement of radio-
nuclidesrsquo activity using the scintillation beta spec-trometer ldquoProgressrdquo
Optional equipment and servicebull Personal computer and printer bull Calibrations for radionuclides not included in the
main library of radionuclides
Progress-Beta
Reference standards IEC 61562
SPC ldquoDozardquoRadiation monitoring equipment
66 67
bull Measurement of gamma activity in foodstuffs soil samples and others environmental objects
bull Identification of radionuclides in the sample bull Automatic correction for sample density bull Self-tests using built-in LED
ldquoPROGRESS-GAMMArdquoSCINTILLATION GAMMA SPECTROMETER
Physical characteristicsDetector bull NaI (Tl) Oslash63times63 mm
Validated measurement geometries bull Marinelli beakers (1 liter) Petri dishes (Oslash90 mm)
etc
Energy range bull 02 divide 30 MeV
Minimum detectable activity Bqsamplebull Cs-137 3 Bqbull Th-232 7 Bqbull Ra-226 8 Bq bull К-40 40 Bq
Electrical characteristics Interface bull USB
Mechanical characteristicsWeight bull No more 120 kg
Complete setBasic complete setbull Scintillation detector unit with NaI (Tl) detector
with integrated power supply amplifier and ADC bull Lead shielding 50 mm bull ldquoProgressrdquo software bull Сheck source for energy calibration (Cs-137 +
K-40)bull Marinelli beakers - 1 liter (5 items) bull Petri dishes Oslash 90 mm (5 items) bull Procedure manual for measurement of activity
of radionuclides using the scintillation gamma spectrometer ldquoProgressrdquo
Optional equipment and servicebull Kit for radon measurements including calibration
of ldquoIC-63rdquo geometry for counting the charcoal samples
bull Personal computer and printer bull Calibrations for user defined geometries bull Calibrations for radionuclides not included in the
main library of radionuclides
Progress-Gamma
Reference standards IEC 61563
ldquoPROGRESS-G(P)rdquoPORTABLE SCINTILLATION GAMMA SPECTROMETERbull Field measurements of gamma activity in environ-
mental objects without sampling (4π geometry)bull Laboratory measurement of gamma activity in
foodstuffs soil samples and others environmental objects
bull Identification of radionuclides in the sample bull Automatic correction for sample densitybull Tests using built-in LED
Physical charachteristicsDetector bull NaI (Tl) Oslash45times50 mmbull Lead shielding 20 mm
Validated measurement geometries bull Marinelli beakers (05 liter) Petri dishes (Oslash90 mm)
etc
Energy range bull 02 divide 30 MeV
Minimum detectable activity in 05-litre Marinelli beaker bull Cs-13710 Bqkgbull К-40100 Bqkgbull Ra-22618 Bqkg bull Th-23216 Bqkg
Minimum detectable activity in 30 min (4π geometry) bull Cs-137 2 Bqkgbull К-40 30 Bqkgbull Ra-226 4 Bqkg bull Th-232 3 Bqkg
Electrical characteristicsPower supply bull Rechargeable batterybull 220 V 50 Hz
Interface bull USB RS-232
Weight bull No more than 60 kg
Complete setBasic complete setbull Scinttillation detector unit with NaI(Tl) bull ldquoProgressrdquo softwarebull Сontrol unit ldquoSputnikrdquo for aquisition and analisys
of spectra with built-in memory for spectral databull Casebull Lead shielding (2 cm) for laboratory usebull 05-litre Marinelli beakers ndash 5 itemsbull Na-22 check sourcebull Power adapter BPS-01bull Operation manualbull Procedure manual for measurement of activity
of radionuclides using the scintillation gamma spectrometer ldquoProgressrdquo
Optional equipment and servicebull Kit for radon measurements with charcoalbull Built-in dose rate meterbull Additional memory (RAM) for storage of 64
spectrabull Additional power adapterbull Notebook and printer
Progress-Gamma
Reference standards IEC 61563
SPC ldquoDozardquoRadiation monitoring equipment
68 69
Physical characteristicsDetectorbull Scintillation detector ZnS (Oslash 60 mm)
Samplebull Thin sample - diameter up to 70 mm bull Preparation technique - electro-depositionbull Thick sample - diameter 70 mm weight
200300 mg bull Preparation technique - application of powders
(prepared by radiochemical concentration by water evaporation or by pounding of mineral samples) onto a planchet with the help of spirit
Energy rangebull 15 divide 8 MeV
Minimum detectable activitybull Thin samples no more than 910-3 Bqsamplebull Thick samples no more than 180 Bqkg
Mechanical characteristicsOverall dimensions weightbull 195times120times210 mm 34 kg
Complete setBasic complete setbull Alpha radiometer ldquoProgress-ARrdquobull Check source (uranium isotopes)
Set of accessoriesbull Procedure manual for measurements of radi-
oactivity using scintillation alpha radiometer ldquoProgress-ARrdquo
bull ldquoProgressrdquo software
ldquoProgress-ARrdquo
bull Measurement of gross activity of alpha emitting radionuclides in thin samples
bull Measurement of gross activity of alpha emitting radionuclides in thick samples
bull Measurement of activity deposited on aerosol filters
ldquoPROGRESS-ARrdquoALPHA RADIOMETER
Several fixed positions of the detector enable to perform measurements in various geometries and to estimate the content ofbull Cs-137 in the whole bodybull I-131 in thyroidbull Co-60 Cs-137 Mn-54 Cr-51 in lungsbull Database for storage of measurement data and
resultsbull Uncertainty calculations based on measurement
databull Self tests using built-in LED
ldquoPROGRESSrdquo WHOLE BODY COUNTER
Physical characteristicsDetectorbull scintillation detector NaI (Tl) Oslash63times63 mm
Energy rangebull 02 divide 28 MeV
Minimum detectable activitybull By Cs-137 in the whole body - 1200 Bqbull By I-131 in thyroid - 100 Bqbull By Co-60 Cs-137 Mn-54 Cr-51 in lungs - 200 Bq
Mechanical characteristicsWeight bull No more than 120 kg
Complete setBasic complete setbull Collimator with rotator and holderbull Detector with incorporated ADCbull Patient chair and table for collimatorbull Check source Na-22bull Procedure manual for lifetime measurement of
gamma-emitting radionuclidesrsquo activity in human body using the gamma-spectrometer of human radiation ldquoProgressrdquo
bull laquoProgressraquo software
Optional equipment and servicebull Program of internal radiation committed internal
radiation effective dose calculation by the stand-ard model
bull Background phantombull Personal computer and printer
Collimator with rotator and holder
SPC ldquoDozardquoRadiation monitoring equipment
70 71
bull Categorization of wastes for the purpose of fur-ther processing including wastes with unknown radionuclide composition
bull Measurements during the incoming waste inspec-tion (accepting for storage disposal)
bull Certification of unconditioned and conditioned wastes in closed containers without opening them (at nuclear plants or at facilities providing collection storage transportation conditioning processing temporal storage and final disposal of radioactive waste)
bull Activity measurement of extended objects in situ without opening the equipment
bull Activity measurement of extended objects after opening (for example assessment of tubes used for oil transportation)
MKG-01D ldquoSADOVNIKrdquoSPECTROMETRY SYSTEM
Physical charachteristicsDetectorbull Detector unit GEM (GMX) with HPGe detector and
multi-positioning cryostat CFG-PMOD4-7 with 7 litre Dewar
bull Dose rate probe BDMG-200
Energy range bull With GEM detector 004 divide 30 MeVbull With GMX detector 0005 divide 15 MeVbull Dose rate probe BDMG-200 ndash 005 divide 30 MeV
Measurement rangebull 110-7 divide 10 Svhbull Relative efficiency of detection (in photopeak) at
13325 MeV (Co-60) 10 divide 150
Electrical characteristicsPower supplybull 220 V 50 Hz
Interfacebull USB
Complete setBasic complete setbull Spectrometric detector unit GEM (GMX) with
HPGe detector and multi-positioning cryostat with 7 litre Dewar
bull Portable digital multichannel analyzer DigiDARTbull Dose rate probe BDMG-200bull Autonomous power supply unit with built-in
batterybull Industrial computer keyboardbull Laser range-finderbull Thermographic printerbull Web-camerabull Device equipped with stepper motor for position-
ing of the spectrometric detectorbull Calibration device with reference sources
(Am-241 Co-60 Ba-133 Eu-152) for energy calibration
bull Removable collimators with end capbull Measurement proceduresbull ldquoClasterrdquo software
bull Measurement of gross alpha activity of alpha-emitting radionuclides
bull Measurement of alpha-emitting radionuclides activity in thin-layer samples meeting alpha-spectrometry requirements
Physical characteristicsDetectorbull Silicon ion-implanted 450 mm2
bull Easy to decontaminate thin windowbull dead layer less than 015 μmbull Background count rate in the range 3 divide 9 MeVbull No more than 09 h-1cm-2 for 450 mm2 detector
Energy rangebull 2 divide 9 MeVbull Lower limit of measurement range (minimum
detectable activity) 01 Bqbull Background count rate no more than 100 counts
in 24 hours
Electrical characteristics Power supplybull 220 V 50 Hz
Interfacebull USB
Complete setBasic complete setbull Detector unit with vacuum measuring chamber
and vacuum control systembull Low noise vacuum pump (type 2FY-05B or
equivalent)bull Check sourcebull ldquoProgressrdquo softwarebull Vacuum tube
MKS-01A ldquoMULTIRAD-ASrdquoALPHA SPECTROMETER
SPC ldquoDozardquoRadiation monitoring equipment
72 73
UCRV-2AIRFLOW MONITOR
bull Monitor of the air flow through filter of centralized multichannel sampling system
bull Radiation monitoring system (RMS) integration for internal exposures determination
bull Volume and flow rate measurements of the air that have passed through a analytical filter
bull Bar-code for filter identificationbull Operation as either standalone unit or as a part of
the RMS
Physical characteristicsMeasurement range of air volume bull 001 divide 9999 m3
Operation temperature range bull minus 20 divide +50 ordmС
Electrical characteristicsPower supply bull 220 V 50 Hz
Interface bull RS-485
PVP-06PORTABLE AIR SAMPLER
Air Sampler PVP-06 is indispensable for monitoring the radiation situation where the concentration of radioactive aerosols in the air does not require a sta-tionary sampling equipment Sampling head PVP-06 provides easy change of filters and cartridges
Purposebull To monitor the concentration of radioactive aero-
sols in the air sites
Controlled aerosolsbull Alpha- and beta-active aerosolsbull Daughter products of decay of radon and thoronbull Iodine isotopes
Physical characteristicsTypes of filtersbull Aerosol AFA-RSP-20bull Iodine AFA SI-20
Flow rate bull 33∙10-4 ndash 233∙10-4 m3s (20 divide 140 l min)
Electrical characteristicsPower supply bull 220 V50 Hzbull The vehicle power supply 108 divide 145 Vbull Internal battery
Minimal working time on internal battery to recharge bull 8 hours
Power consumption (at a flow rate of 100 lmin) bull 40 VA
Environment characteristicsOperating temperature bull minus 10 divide +40 deg C
Maximum humidity bull 90
Pressure bull 860 to 1060 hPA
Noise generated by the pump bull lt 55 dBA at 1 m
Mechanical characteristicsDimensions weight bull 241 times 108 times 160 mm 28 kg
Case material bull Plastic
Complete setbull Air sampler PVP-06bull AC power adapterbull Filters AFA-RSP-20 - 100 pcsbull Packaging for filters - 40 pcsbull Casebull Operation manualbull Calibration certificate
Optional equimpient bull Kit for sampling sorption columns of activated
carbon Ř head of sorption columns with protective
covers Ř activated charcoal SKT-3 - 1 pkg (02 L) Ř charocoal samples SC-13 - 8 pcs
bull Car charger bull Tipod bull Shoulder strapbull Calibration stand bull Filters AFA SI-20 - 100 pcs
Consumablesbull Aerosol filters AFA RSP-20bull Iodine filters AFA SI-20
SPC ldquoDozardquoRadiation monitoring equipment
74 75
Calibration of gamma dose and dose rate meters
Calibration ofbull Ambient equivalent dose H(10) meters (Sv Svh)bull Personal equivalent dose Hp(10) meters (Sv Svh)bull Exposure dose X meters (R Rh)bull Two sources in irradiator bull Select source and collimator opening using
tumbler
UPG-P DESKTOP GAMMA BEAM IRRADIATOR
Physical characteristicsRange of reproduced dose rate bull 05 μSvh divide 10 mSvh (50 μRh divide 100 mRh)
Sources activities bull 6times106 6times108 Bq (02 20 mCi) Cs-137
Overall dimensions bull 1250times400times300 mm
Irradiator weight bull Not more than 37 kg
Calibration bench weight bull Not more than 15 kg
Reference standards IEC 60846 IEC 61526
Physical characteristicsDetectorbull Silicon
Measurement range EEC measurement bull Measurement range of radon EEC
10 divide 10bull106 Bqbullm-3
bull Measurement range of thoron EEC 05 divide 10bull104 Bqbullm-3
bull Air flow through the filter 100plusmn05 lmin
Concentration measurementbull Measurement range of radon-222 concentration
in air 10 divide 20bull106 cpsbull Measurement range of 216Po(ThA)
1bull10-3 divide 1bull102 cpsbull Air sampler flow rate
10plusmn02 lminbull Measurement range of radon-222 concentration
in water samples 6 divide 800 Bqbullkg-1
bull Measurement range of radon-222 flux from soil surface 20 divide 103 mBqsbullm2
bull Measurement range of radon-222 concentration with preliminary sampling of air using air sam-plers 20 divide 107 Bqbullm-3
bull Measurement range of radon-222 concentration in samples of soil air 103 divide 106 Bqbullm-3
Operation temperature range bull 1 divide 35 ordmC
Electrical characteristicsPower supply bull 80 VA
Mechanical characteristicsOverall dimensions weight bull 220times200times165 mm 36 kg
ldquoALPHARAD PLUSrdquoRADON THORON amp THEIR PROGENY MONITORbull Measurement of radon and thoron concentration
and effective equivalent concentration (EEC)bull In the airbull In the indoor air of residential public and industri-
al buildings and structuresbull Measurement of radon in drinking water sourcesbull Measurements of radon flux from the soil surface
at land plots allocated for construction of houses public buildings and industrial facilities
bull Measurements of radon concentration in soil air
Reference standards IEC 61577
SPC ldquoDozardquoRadiation monitoring equipment
76 77
UKPN-2M-D NEUTRON BEAM IRRADIATOR
Reference standards IEC 61005 61322
Calibration of neutron dose and dose rate meters
Calibration ofbull Ambient equivalent dose H(10) meters (Sv Svh)bull Personal equivalent dose Hp(10) meters (Sv Svh)bull Flux density of neutrons (cm-2∙s-1)bull Transfer container for temporary storage of
sources bull Red light signal of source working position
Physical carachteristicsRange of reproduced dose ratebull 20 divide 800 μSvh
Range of reproduced flux densitiesbull 10 divide 400 cm-2∙s-1
Type of a source in use bull Pu-Be
Activity of a source in usebull 24х1011 Bq (with density of 107 s-1)
Overall dimensions weight no morebull 3000x750x2000 mm 300 kg
Required room dimensionsbull not less than 7x3x3 m
Electrical characteristicsPower supply bull 220 V 50 Hz
Calibration of gamma dose and dose rate meters
Calibration ofbull Ambient equivalent dose H(10) meters (Sv Svh)bull Personal equivalent dose Hp(10) meters (Sv Svh)bull Exposure dose X meters (R Rh)bull Four sources in irradiator bull Select source and move to working position
return to storage position using special rodbull Transfer container for temporary storage of
sources bull Red light signal of source working position
UPGD-2M-DGAMMA BEAM IRRADIATOR
Physical characteristicsRange of reproduced dose rate bull 05 μSvh divide 50 mSvh (50 μRh divide 5 Rh)
Maximum activity of source bull 2times1011 Bq (50 Ci) Cs-137
Overall dimensionsbull Irradiator 800times500times500 mmbull Guide rails length 30 mbull Height 16 mbull Weight not more than 700 kgbull Required room dimensions not less than 7x3x3 m
Electrical characteristicsPower supply bull 220 V 50 Hz
UPGD-2M-D
Reference standards IEC 60846 IEC 61526 IEC 61066
SPC ldquoDozardquo
78 79
Contents
MEASURING UNITS
DBG-S11D wide range gamma area monitor 40
UDKS-100 gamma and X-ray area monitor 41
UDMN-100 neutron area monitor 41
ALARM UNITS
BAS-2 ldquoMICROrdquo external visual alarm 42
BZS-2 ldquoMicrordquo external audible alarm 42
Illuminated warning signs 43
ldquoImpulsrdquo external display unit 43
UIM-3D area monitor count rate meter 44
DKG-05D personal gamma dosimeter 46
DVS-02D gamma-neutron personal electronic dosimeter 47
DVGI-8D new pen-type personal ionization chamber dosimeters 48
DKG-02U ldquoARBITERrdquo wide range gamma-dosimeter 49
DKG-07D ldquoDROZDrdquo gamma-dosimeter 50
MKS-15D ldquoSNEGIRrdquo multi ndash purpose radiation survey meter 51
SRPS-05D gamma monitor 52
DOZA-TLD multipurpose TLD system 53
DKS-96 universal radiation survey meter 54
EXTERNAL PROBES ALPHA
Alpha BDZA-96 55
Alpha BDZA-96B 55
Alpha BDZA-96M 55
Alpha BDZA-96S 55
Alpha BDZA-96T 55
EXTERNAL PROBES BETA
Beta BDZB-96 56
Beta BDZB-99 56
Beta BDZB-96B 56
Beta BDZB-96S 56
EXTERNAL PROBES GAMMA
Gamma BDKS-96B 57
Gamma and beta BDKS-96S 57
Gamma BDMG-96 57
EXTERNAL PROBES GAMMA
Gamma-search BDVG-96 58
Gamma-search BDPG-96 58
ContentsRadiation monitoring systemldquoPELIKANrdquo Radiation monitoring system (RMS) 6
BDMG-101 high range gamma area monitor 10
DBG-S11D wide range gamma area monitor 11
BDRG-52 high range gamma area monitor for accident and post-accident conditions 12
UDGP-01 Liquid technological environments monitor 13
UDMN-100 neutron area monitor 14
UDKG-100 Wel Liquid gamma monitor 14
BOP-1M data processing and transmission unit 15
UDA-1AB particulate monitor 16
UDG-1B noble gas monitor 17
UDG-03D noble gas monitor 18
UDI-1B iodine monitor 19
UDGB-01 noble gasesH-3C-14 monitor 20
UDGP-01 steam generator leakage monitor 21
UPPVM air flow parameters monitor 22
ldquoIMPULSrdquo external display unit 23
BI-2 remote display amp alarm unit 24
BASBAS-1s external alarm 25
SKGAV stack monitor 26
RMS software 28
RMS workstation ndash operator console 29
Configurator software 29
RM RACK radiation monitoring rack 30
SRKS-01D criticality accident alarm system 32
ldquoATLANT-Mrdquo environmental radiation monitoring system 34
ldquoBREEZErdquo high-volume air sampler 35
ldquoGAMMA-SENSORrdquo gamma-survey system 36
Radiation monitoring equipmentAREA MONITOR ldquoFREGATrdquo 38
BPI-1D local display unit 39
80
Gamma-search BDPG-96M 58
Gamma BDKG-96 stainless steel casing for geologic applications well logging 59
EXTERNAL PROBES NEUTRON
Neutron BDMN-96 59
Neutron-search BDKN-96 59
RZB-05D Hand-foot-clothing monitor 60
RZBA-04-04M whole body contamination monitor 61
RZA-05D alpha hand-monitor 62
UMF-2000 low level alpha- beta- counter 63
DRK dose area product meter 64
ldquoPROGRESS-BETArdquo scintillation beta spectrometer 65
ldquoPROGRESS-GAMMArdquo scintillation gamma spectrometer 66
ldquoPROGRESS-G(P)rdquo portable scintillation gamma spectrometer 67
ldquoPROGRESS-ARrdquo alpha radiometer 68
ldquoPROGRESSrdquo whole body counter 69
MKG-01D ldquoSADOVNIKrdquo spectrometry system 70
MKS-01A ldquoMULTIRAD-ASrdquo alpha spectrometer 71
UCRV-2 airflow monitor 72
PVP-06 portable air sampler 73
ldquoALPHARAD PLUSrdquo radon thoron amp their progeny monitor 74
UPG-P desktop gamma beam irradiator 75
UPGD-2M-D gamma beam irradiator 76
UKPN-2M-D neutron beam irradiator 77
SPC ldquoDozardquo
2 3
Manufacture and production capacitiesNew sophisticated machines and equipment ensure large production volume Own technology and highly skilled staff are key factors that allow us to guarantee a highest quality of suggested products
We use high technology laser metal sawing ma-chines powerful robotic processing equipment automated machine for board surface mount and some other Few years ago ldquoDozardquo built up new production building (1000 msup2) Now we have totally 2000 msup2 of production facilities and other 2000 msup2 are used for office and warehouse
Our product portfolioOur high scientific potential an extremely power-ful RampD and high adaptability to customer specs and markets needs allow us to supply reliable and cost-effective solutions which meet all requirements of domestic and international (IEC ISO) standards Our key product lines are portable dosimeters and radiometers spectrometers radiation monitoring system environmental surveillance stations critical accident alarm system medical equipment calibra-tion equipment Spare parts policy we commit to provide spare parts for our devices as soon as it is required by our customers
Business developmentWe are actually selling more than 200 different products in 20 countries We constantly increase our business volume in BRICS countries (Russia China India) and other newly developed regional powers We move fast forward in getting new accounts in Europe South America Asia and Middle East Our key target is to develop our business thru new partnership all over the world Any new partner is very welcome
ANRI magazine We have been releasing ldquoThe ANRI Journalrdquo (Radia-tion monitoring equipment and news) since 1994 We issue the most relevant research materials reports and articles dedicated to Health Physics radiation problematic methodology metrology and new equipment This Journal is referenced in Russian Federal Agency on Press and Mass Communication catalogue So ldquoThe ANRIrdquo is the exclusive periodical Russian journal focused on practical aspects of ra-diation monitoring It is also referenced in Chemical Abstracts
Quality management system ldquoDozardquo quality management system meets GOST ISO 9001-2011 requirements and is being a base of corporate management system Main company document that determines the principles of business doing operation and permanent improvement of the quality management system according to the principles and requirements of international stand-ards is the Quality Control Chart
Metrological service ldquoDozardquo has a quite developed metrological service based on the standards for dosimeters and radiom-eters calibration and verification pulse and static X-ray machines complying with ISO 4037 refer-ence X-ray dosimeter air flow volume calibration machine radioactive gases radiometer calibration standard gamma-sources Cs-137 Co-60 Co-57 Am-241 neutron Pu-Be sources alpha- and beta-sources and spectrometric sources Our metrological service is one of the best equipped laboratories in Russia It is accredited in performing primary and periodical verification and calibration More than 30000 verifi-cations per year are done in our lab
Our staff Over 200 people including 12 PhD and 85 engineers represent the most valuable capital of ldquoDozardquo
Seven employees of our company were awarded for their participation in elimination of the Chernobyl accident consequences Our experts participate in development and implementation of normative and methodological documents which make the basis of radiation safety in Russia
Among our specialists there are experts of bull Scientific and Technical Board of the State Atomic
Energy Corporation ldquoRosatomrdquo bull Technical committee 45 IEC ldquoNuclear instrumen-
tationrdquo bull Technical committee of 413 Rosstandart bull Coordination Council of the ldquoRosatomrdquo on the
development of the environmental radiation monitoring system (ERMS)
bull Working group of the ldquoRosatomrdquo on developing the ldquoIntegrated complex safety management system in the field of Nuclear Powerrdquo
bull Association of Medical Physicists of Russia (AMPR)
4
Training Since 1994 ldquoDozardquo has been organizing different types of training Best specialists from national and international research centers come to ldquoDozardquo We provide our trainees with up-to-date methodological and standard norms documents In order to create an independent educational entity in 2007 ldquoDozaldquo founded Educational and Methodological Center ldquoMonitoring and Safetyrdquo This Center is functioning under the License of the Moscow Department of Education
Few references20 NPP use our equipment More than 1000 med-ical institutions are our customers The biggest Ice-breaker in the world is equipped with our RMS Within 2013-2014 we have successfully supplied 450 measuring channels to the bigger Mining and Chemical Complex
Radiation Monitoring
System
Radiation monitoring system SPC ldquoDozardquo
6 7
More than 100 Radiation Monitoring Systems ldquoPelikanrdquo are installed and operating successfully at facilities representing different industries including research reactors nuclear power plants and the icebreaker ldquo50 Years of Victoryrdquo
FeaturesThe RMS ldquoPelikanrdquo constitutes a complex of independent units (intended for measurement of different parameters) that are interconnected into common information network The RMS network
is built using Ethernet IEEE 8023 technology it accommodates measurement devices and workstations as clients The network includes two servers (main and hot standby) or alternatively it can have no server at all The RMS allows performing all commutations necessary for repair or calibration of measurement units in hot mode without interrupting normal network operation
ldquoPELIKANrdquoRADIATION MONITORING SYSTEM (RMS)
Major users of ldquoPelikanrdquo RMS system are Nuclear Power Plants in Russia Ukraine China and India as well as Rosatom Rospotrebnadzor Ministry of Emergency Situations Rosstandard Ministry of Health Ministry of Defense Russian Railways laboratories and other companies and organizations
bull GMP ldquoZvesdochkardquo Severodvinskbull Mining and Chemical Complex Zheleznogorskbull Institute of Physics and Power Engineering
Obninskbull Russian Research Institute of Technical Physics
Sarov
REFERENCE
bull Leningrad NPPbull laquoAtomflotraquobull ldquoZvesdardquo factory Bolrsquoshoy Kamenrsquobull Petersburg Nuclear Physics Institutebull Civil Security Department Moscowbull ldquoRosatomrdquo Corporation MosNPO ldquoRadonrdquobull ldquoRosatomrdquo Corporation ldquoSNIIP-Systematomrdquobull ldquoRosenergoatomrdquo Concern Moscowbull Norilsk Mining and Smelting producerbull Russian Research Institute ldquoVNII Avtomatikardquo
Moscowbull Kudankulam NPP Indiabull Tianwan NPP China
Radiation monitoring system SPC ldquoDozardquo
8 9
SKGAV Stack monitor
UPPVM Air flow parameters monitor
RM Rack
UDG-1B Noble gas monitor
UDGB-01Noble gasesH-3C-14
monitor
UDA-1AB Particulate monitor
UDI-1BIodine monitor
UDGP-01 Steam generator leakage
monitor
RMSworkstation
Ethernet switch
Ethe
rnet
RS
-485
RMS workstationServer
DBG-S11D Wide range gamma area monitor
BDMG-101 High range gamma area monitor
UDMN-100 Neutron area monitor
BDRG-52 High range gamma area monitor
BASBAS-1s External alarm
BOP-1M Data processing and
transmission unit
RADIATION MONITORING SYSTEM
Ethe
rnet
RS
-485
BI-2 Remote display amp alarm unit
ldquoImpulsrdquoExternal Display Unit
UDKG-100 Wel Liquid gamma monitor
Ethernet RS-485 Ethernet RS-485
UDG-03D Noble gas monitor
UDGP-01 Liquidtechnological environment monitor
Radiation monitoring system SPC ldquoDozardquo
10 11
bull Continuous automatic monitoring of the ambient dose equivalent rate
bull Нigh temperature range (up to 120 degC)
BDMG-101 HIGH RANGE GAMMA AREA MONITOR
Physical characteristicsbull detector ndash ionization chambers
Measurement rangebull MIC-1 5∙10-5 divide 200 Svhbull MIC-2 5∙10-4 divide 1000 Svhbull MIC-3 1∙10-5 divide 100 Gyhbull MIC-4 5∙10-3 divide 10000 Gyh
Energy rangebull 005 divide 30 MeV
temperature rangebull ionization chamber module MIC-1
minus 30 divide +120 degCbull electrometric module MIC-2 MIC-3 MIC-4 ME
minus 30 divide +60 degC
Electrical characteristicsbull interfaces RS-485bull cable length between MIC and ME up to 30 m
Mechanical characteristicsbull Protection index IP 65
Overall dimensions weightbull ME Oslash105times293 mm 23 kgbull MIC-1 Oslash85times206 mm 12 kgbull MIC-2 Oslash45times156 mm 03 kgbull MIC-3 Oslash136times226 mm 09 kgbull MIC-4 Oslash35times92 mm 02 kg
BOP-1M
Reference standards Nuclear IEC 60846 IEC 60532
DBG-S11D WIDE RANGE GAMMA AREA MONITOR
Continuous automatic monitoring of the ambient dose equivalent rate
Physical characteristicsbull Detector ndash GM counters
Measurement rangebull DBG-S11D 01 μSvh divide 10 mSvhbull DBG-S11D-01 01 μSvh divide 10 Svhbull DBG-S11D-02 01 μSvh divide 100 Svh
Energy rangebull 005 divide 30 MeV
Temperature range bull minus 40 divide +50 ordmC
Electrical characteristicsbull Interfaces RS-485 USB
Mechanical characteristicsbull Protection index IP 68bull Paint decontaminable
Overall dimensions weightbull DBG-S11D Oslash 68times141 mm 065 kg bull DBG-S11D-01 Oslash 68times179 mm 07 kgbull DBG-S11D-02 Oslash 68times179 mm 07 kg
Versionsbull DBG-S11Dbull DBG-S11D-01bull DBG-S11D-02
BOP-1M
Reference standards Nuclear IEC 60532
Versionsbull stainless steel 100 cm2 ionization chamber
module (MIC-1) and electrometric module (ME)bull stainless steel 20 cm2 ionization chamber module
(MIC-2) and electrometric module (ME)bull duralumin 500 cm2 ionization chamber module
(MIC-3) and electrometric module (ME)bull titanium 2 cm2 ionization chamber module
(MIC-4) and electrometric module (ME)
Radiation monitoring system SPC ldquoDozardquo
12 13Reference standards EMC IEC 61010 IEC 61000-6-2 Seismic IEC 60980
bull Continuous automatic monitoring of the ab-sorbed dose rate
bull Monitoring inside containmentbull Delivery assembled detector and communication
linebull Communication line include inter wall protective
tubebull Hermetic communication line filled dry nitrogen
Physical characteristicsbull detector - stainless steel ionization chamber
Measurement range bull 10-3 divide 105 Gyh
Energy range bull 006 divide 30 MeV
Temperature range bull detector
0 divide 207 ordmC continuous
250 ordmC during 1 hour bull electrometric module 0 divide +60 ordmC
Detector operating pressure bull 07 МPa
Electrical characteristicsbull Interfaces RS-485bull detector-electrometric module cable length up
to 70 m
BDRG-52 HIGH RANGE GAMMA AREA MONITOR FOR ACCIDENT AND POST-ACCIDENT CONDITIONS
Ionization chamber
Mechanical characteristicsProtection index bull detector - IP 65bull electrometric module - IP 23bull Paint stainless steel
Overall dimensions weight bull detecting unit Oslash50х220 mm 3 kgbull inter wall protective tube Oslash 159 length (by order)
1200 ndash 1600 mm 60 kgbull electrometric module 420x420x120 mm 8 kg
Reference standards Nuclear IEC 60951 EMC IEC 61010 IEC 61000-6-2 Seismic IEC 60980
Continuous monitoring of technological environ-ments liquid couples sludges etc bull On line gamma spectrometry
Physical characteristicsbull Detector ndash scintillator CsI NaI
Measurement range bull Gamma-activity 10bull104 divide 20bull108 Bqm3
Energy range bull gamma 005 divide 15 MeV
Temperature range bull minus 10 divide +80 ordmС
UDGP-01 LIQUID TECHNOLOGICAL ENVIRONMENTS MONITOR
Electrical characteristicsbull Interfaces RS-232 RS-485 Ethernetbull programmable relay output (SPDT relay)
Mechanical characteristicsbull Protection index IP 65bull Paint decontaminable
Overall dimensions weight bull Detector unit
CsIOslash 60x360 mm17 kg NaIOslash 35x750 mm26 kg
bull Data processing and transmission unit BOP-1sp 280x220x114mm 43 kg
Alarmbull Sound alarm 80 divide 100 dBA at distance 1 mbull Visual alarm green yellow redbull Connection of the external alarm unit of ldquoBASrdquo
type
Radiation monitoring system SPC ldquoDozardquo
14 15
BOP-1M DATA PROCESSING AND TRANSMISSION UNIT
bull Processing of data incoming from detecting blocks UDMN-100 DBG-S11D UDKG-100 BDMG-101 BDRG-52
bull Data transmission to the network bull Data transmission to the mobile computer bull Storage of thresholds values and parameters of
detecting blocksbull Power supply and diagnostics of detecting blocks bull Generation of the alarm signals of the excess of
preset thresholdsbull Data backup in the non-volatile memory
Physical characteristicsbull Quantity of joined detecting blocks and alarm
units ndash up to 20bull Temperature range minus 40 divide +50 ordmC
Electrical characteristicsbull Power supply 85 divide 260 V 47 divide 440 Hzbull Interfaces RS-232 RS-485 Ethernet bull programmable relay output (SPDT relay)
Mechanical characteristicsbull Protection index IP 65 bull Paint decontaminable
Overall dimensions weightbull 298times220times114 mm 5 kg
Reference standards EMC IEC 61010 IEC 61000-6-2 Seismic IEC 60980
Continuous automatic monitoring of the neutron-radiations ambient dose equivalent ratebull Spherical polyethylene moderator Oslash 239 mm
UDMN-100 NEUTRON AREA MONITOR
Physical characteristicsbull detector ndash scintillator ZnS(Ag) Li-6
Measurement range bull 01 μSvh divide 01 Svh
Energy range bull 0025 eV divide 100 MeV
Temperature range bull minus 45 divide +50 ordmC
Electrical characteristicsbull Interfaces RS-485
Reference standards Nuclear IEC 61005 IEC 61322 EMC IEC 61010 IEC 61000-6-2 Seismic IEC 60980
UDKG-100WEL LIQUID GAMMA MONITOR
Mechanical characteristicsbull Protection index IP 65bull Paint decontaminable
Overall dimensions weight bull 428times258times347 mm 115 kg
Continuous automatic monitoring of the gamma radiation flux Operation in the rocks ore liquid media and sludge
Physical characteristics bull detector ndash NaI (Tl) Oslash 18x30 mm
Measurement range bull 40 divide 8104 s-1cm-2
Energy range bull 01divide 30 MeV
Temperature rangebull minus 40 divide +50 degC
Electrical characteristics bull Interfaces RS-485
Mechanical characteristics bull Protection index
Ř BDKG-100 IP 68 Ř Interface block BS-16 IP 65
bull Paint stainless steel bull Overall dimensions weight
Ř Detector unit BDKG-100 Oslash 38times530 mm 3 kg Ř Interface block BS-16 176times80times64 07 kg
Radiation monitoring system SPC ldquoDozardquo
16 17
UDG-1B NOBLE GAS MONITOR
Continuous automatic monitoring of the beta-emit-ting radioactive gases concentration in the working air and in the air in ventilation ducts and stacksbull Gamma background compensation bull Audible and visual alarm signals of the excess of
preset thresholds bull Periodic calibration by means of standard beta-
source
Physical characteristicsbull Silicon detectors (2 pcs for measurement and for
background compensation)bull Air flow rate 10 divide 100 lminbull Operation temperature range minus 10 divide +50 ordmС
Measurement range bull 104 divide 6109 Bqm3
Energy range bull 008 divide 30 MeV
Electrical characteristicsbull Power supply 85 divide 260 V 47 divide 440 Hzbull Interfaces RS-232 2timesRS-485 Ethernetbull programmable relay output (SPDT relay)bull Analog output 4-20 mA (optional)
Mechanical characteristicsbull Protection index IP 65bull Paint decontaminable
Overall dimensions weight bull Stationary version 395times240times304 mm 295 kgbull Mobile version with pump unit BN-1
395times468times950 mm 543 kg
Alarmbull Sound alarm 80 divide 100 dBA at distance 1 mbull Visual alarm green yellow red
Mobile version with pump unit BN-1
Stationary version
Reference standards Nuclear IEC 60761 IEC 62302 EMC IEC 61010 IEC 61000-6-2 Seismic IEC 60980
bull Connection of the external alarm unit ldquoBASrdquo type
Versionsbull Stationary versionbull Stationary version with pump unit BN-1bull Mobile version with pump unit BN-1
UDA-1AB PARTICULATE MONITOR
Stationary version
Continuous automatic monitoring of the alpha- and beta- radioactive aerosol concentration in the work-ing air and in the air in ventilation ducts and stacksbull Radon toron progenies and gamma background
compensation bull On line alpha spectrometrybull Audible and visual alarm signals of the excess of
preset thresholds bull Control of electromagnetic valves when operating
with the external air sampling linebull Control of pump unit bull Periodic calibration by means of standard beta-
and alpha-sources
Physical characteristicsbull Silicon specrometric detectors (2 pcs for measure-
ment and for background compensation)bull Filter tape types LFAS FSLWbull Tape consumption (when continuous operation)
10 m50 daysbull Air flow rate 10 divide 100 lmin bull Operation temperature range minus 10 divide +50 ordmС
Measurement range bull Alpha 10-2 divide 2105 Bqm3 bull Beta 10-1 divide 106 Bqm3
Energy range bull Alpha 30 divide 90 MeV bull Beta 005 divide 30 MeV
Electrical characteristicsbull Power supply 85 divide 260 V 47 divide 440 Hzbull Interfaces RS-232 2timesRS-485 Ethernet bull Programmable relay output (SPDT relay)bull Analog output 4-20 mA (optional)
Mechanical characteristicsbull Protection index IP 65bull Paint decontaminable
Overall dimensions weight bull Stationary version 389times260times304 mm 156 kg bull Mobile version with pump unit BN-1
389times468times950 mm 384 kg
Alarmbull Sound alarm 80 divide 100 dBA at distance 1 mbull Visual alarm green yellow redbull Connection of the external alarm unit ldquoBASrdquo type
Versionsbull Stationary versionbull Stationary version with pump unit BN-1bull Mobile version with pump unit BN-1
Reference standards Nuclear IEC 60761 IEC 61172 EMC IEC 61010 IEC 61000-6-2 Seismic IEC 60980
Mobile version with pump unit BN-1
Radiation monitoring system SPC ldquoDozardquo
18 19
Physical characteristicsbull Scintillation detectors CsI(Tl) (2 pcs for measure-
ment and for background compensation)bull Cartridge activated charcoal
Measurement range bull 37 divide 37106 Bqm3
Energy range bull 006 divide 30 MeVbull Air flow rate 20 divide 40 lminbull Operation temperature range minus 10 divide +50 ordmС
Electrical characteristicsbull Power supply 85 divide 260 V 47 divide 440 Hzbull Interfaces RS-232 2timesRS-485 Ethernetbull Programmable relay output (SPDT relay)bull Analog output 4-20 mA (optional)
Mechanical characteristicsbull Protection index IP 65bull Paint decontaminable
Overall dimensions weight bull Stationary version 448times323times479 mm 35 kgbull Mobile version with pump unit BN-1
448times468times950 mm 578 kg
Reference standards Nuclear IEC 60761 IEC 61171 EMC IEC 61010 IEC 61000-6-2 Seismic IEC 60980
Alarmbull Sound alarm 80 divide 100 dBA at distance 1 mbull Visual alarm green yellow redbull Connection of the external alarm unit of ldquoBASrdquo
type
Versionsbull Stationary versionbull Stationary version with pump unit BN-1bull Mobile version with pump unit BN-1
Сontinuous automatic monitoring radioiodine concentration in the air at working places and in ventilation ducts and stacksbull Measurement of volumetric activity of radionu-
clides I-131 I-132 I-133 I-135 in the airbull On line gamma spectrometrybull Gamma background compensation bull Performance self-test by means of Am-241 check
source implanted into the detectorbull Audible and visual alarm signals of the excess of
preset thresholdsbull Periodic calibration by means of standard source
UDI-1B IODINE MONITOR
Physical characteristicsbull Silicon detector 2 pcs (for measurement and for
background rejection)bull Air flow rate 10 divide 100 lminbull Operation temperature range minus 10 divide +50 ordmС
Measurement range bull 104 divide 11010 Bqm3
Energy rangebull 006 divide 30 MeV
Electrical characteristicsbull Power supply 120 Vbull Interface RS-485
Mechanical characteristicsbull Protection index IP 65bull Paint decontaminable
Overall dimensions weight bull 474х246х243 mm 295 kg
UDG-03D NOBLE GAS MONITOR
Measurement of volumetric activity of beta-emitting radioactive gases (argon krypton xenon) adapted to the measurement of the rapidly changing volume activity in various technological processesbull Gamma background compensationbull Periodic calibration by means of standard beta-
source
Reference standards Nuclear IEC 60761 IEC 62302 EMC IEC 61010 IEC 61000-6-2 Seismic IEC 60980
Radiation monitoring system SPC ldquoDozardquo
20 21
Continuous automatic monitoring of steam genera-tor primary to secondary leakagebull On line gamma spectrometrybull N-16 monitoringbull Performance self-test by means of Am-241 check
source implanted into the detectorbull Audible and visual alarm signals of the excess of
preset thresholds
Physical characteristics
UDGP-01 STEAM GENERATOR LEAKAGE MONITOR
bull detector ndash scintillator CsI Oslash 40х100 mm
Measurement range bull High energy gamma-activity (N-16)
15bull103 divide 20bull108 Bqm3
bull General gamma-activity 10bull104 divide 20bull108 Bqm3
Energy range bull General gamma 005 divide 15 MeV bull in integral spectral band of energy
5000 divide 7200 keV bull temperature range minus 10 divide +80 ordmС
BOP-1SP
Electrical characteristicsbull Power supply 85 divide 260 V 47 divide 440 Hzbull Interfaces RS-232 RS-485 Ethernetbull programmable relay output (SPDT relay)
Mechanical characteristicsbull Protection index IP 65bull Paint decontaminable
Overall dimensions weight bull Detector unit Oslash 60x360 mm17 kgbull Data processing and transmission unit BOP-1sp
280x220x114mm 43 kgbull Collimator Oslash 350x455 mm 150 kg
Alarmbull Sound alarm 80 divide 100 dBA at distance 1 mbull Visual alarm green yellow redbull Connection of the external alarm unit of ldquoBASrdquo
type
Reference standards Nuclear IEC 61453 EMC IEC 61010 IEC 61000-6-2 Seismic IEC 60980Reference standards Nuclear IEC 60761 IEC 60710 IEC 60951-2 EMC IEC 61010 IEC 61000-6-2 Seismic IEC 60980
Ionization chambe 10 liters
UDGB-01T1
Physical characteristicsbull Detectors - stainless steel ionization chambersbull Air flow rate 10 divide 100 lminbull Operation temperature range minus 10 divide +50 ordmС
Volumes of ionization chambers bull UDGB-01T UDGB - 01T1 100 litersbull UDGB-01T2 01 liter
Measurement range (Kr-85) bull UDGB-01T UDGB-01T1 10104 divide 50109 Bqm3
bull UDGB-01T2 109 divide 501014 Bqm3
Measurement range (H-3) bull UDGB-01T UDGB-01T1 50104 divide 50109 Bqm3
bull UDGB-01T2 50109 divide 501014 Bqm3
Electrical characteristicsbull Power supply 85 divide 260 V 47 divide 440 Hzbull Interfaces RS-232 2timesRS-485 Ethernetbull Programmable relay output (SPDT relay)bull Analog output 4-20 mA (optional)
Mechanical characteristicsbull Protection index IP 23bull Paint decontaminable
Continuous automatic monitoring of the beta-emitting radioactive gases including tritium and carbon-14 concentration in the air at working places and in ventilation ducts and stacksbull Audible and visual alarm signals of the excess of
preset thresholds bull Monitoring of the noble gase activity in gaseous
effluents and ventilation air for accident and post-accident conditions
Overall dimensions weight bull UDGB-01T 381times343times716 mm 30 kgbull UDGB-01T1 260times320times175 mm 125 kgbull Ionization chamber 100 liters Oslash 250times600 mm
6 kgbull UDGB - 01T2 381times343times716 mm 27 kg
Alarmbull Sound alarm 80 divide 100 dBA at distance 1 mbull Visual alarm green yellow redbull Connection of the external alarm unit ldquoBASrdquo type
Versionsbull UDGB-01T - with built-in ionization chamber
100 litersbull UDGB-01T2 - with built-in ionization chamber
01 literbull UDGB-01T1 - with remote ionization chamber
100 liters
UDGB-01NOBLE GASESH-3C-14 MONITOR
Radiation monitoring system SPC ldquoDozardquo
22 23
Physical characteristicsLength of communication cablebull up to 1200 m
Character height bull ldquoImpuls-910-Rrdquo 100 mmbull ldquoImpuls-915-D4Srdquo 150 mmbull ldquoImpuls-927-D4Srdquo 270 mm
Operating temperature rangebull ldquoImpuls-910-Rrdquo 0 divide +50 ordmCbull ldquoImpuls-915-D4Srdquo ldquo-927-D4Srdquo minus 40 divide +50 ordmC
Electrical characteristicsbull Power supply 220 V 50 Hz
Mechanical characteristicsProtection index bull ldquoImpuls-910-R IP 44bull ldquoImpuls -915-D4Srdquo ldquo-927-D4Srdquo IP 65
Overall dimensions weight bull ldquoImpuls-910-Rrdquo 400times160times60 mm 3 kgbull ldquoImpuls -915-D4Srdquo 815times250times80 mm 5 kgbull ldquoImpuls -927-D4Srdquo 1250times330times80 mm 5 kg
ldquoIMPULSrdquoEXTERNAL DISPLAY UNIT
Display of data received from monitors of RMS
External display unit ldquoImpuls-910-Rrdquo
Reference standards EMC IEC 61010 IEC 61000-6-2 Seismic IEC 60980
Continuous monitoring of the flow rate temperature and humidity of the gas flowbull Definition of air volume flow rate in stacks taking
into account temperature and humidity of the air
UPPVM AIR FLOW PARAMETERS MONITOR
Physical characteristicsMeasurement range bull air flow velocity 1 divide 20 msbull air temperature 0 divide +80 ordmСbull air humidity 10 divide 95
Electrical characteristicsbull Power supply 220 V 50 Hz bull Interfaces RS-232 Ethernet
Mechanical characteristicsProtection index bull BSPP-1st BSPP-1tv BOP-1s IP 65bull PP-st IPTV IP 54bull Paint decontaminable
Overall dimensions weight bull air velocity probe PP-st 60times38times136 mm 015 kgbull Interface block BSPP-1st 125times155times73 mm 07 kgbull air temperature and relative humidity probe
IPTV-056-A 333times100times60 mm 07 kgbull Interface block BSPP-1tv 125times155times73 mm 07 kgbull Data processing and transmission unit BOP-1s
280x233x111 mm 8 kg
Reference standards Nuclear ISO 2889 EMC IEC 61010 IEC 61000-6-2 Seismic IEC 60980
BOP-1S
Radiation monitoring system SPC ldquoDozardquo
24 25
BASBAS-1S EXTERNAL ALARM
Generation of audible and visual signals of the excess of preset thresholds RMS monitorsbull Audible alarm 80 divide 100 dBA at distance 1 mbull Visual alarm green yellow red
Distance from RMS monitorbull BAS up to 20 mbull BAS-1s up to 1200 m
Power supply bull 220 V 50 Hz
Overall dimensions weight bull BAS 145times108times460 mm 18 kg bull BAS-1s 166times109times466 mm 18 kg
Reference standards EMC IEC 61010 IEC 61000-6-2 Seismic IEC 60980
Physical characteristicsLength of communication cablebull up to 1200 m
Displayed page size bull 4 lines of 20 characters
Volume of loaded information bull 10 pages
Change of pagesbull programmed or by pressing a button
Operating temperature rangebull minus 40 divide +50 ordmC
Electrical characteristicsbull Power supply 9 divide 18 VDCbull Interfaces RS-485
Mechanical characteristicsbull Protection index IP 65bull Overall dimensions weight 222times164times73 mm
40 kg
BI-2 REMOTE DISPLAY amp ALARM UNIT
bull Display of data received from monitors of RMSbull Audible and visual alarms on exceeding preset
thresholds of the RMS equipment bull Individual threshold setting for each measure-
ment channelbull Audible alarm 80 divide 100 dB at a distance of 1 m bull Visual alarm red yellow green
Reference standards EMC IEC 61010 IEC 61000-6-2 Seismic IEC 60980
Radiation monitoring system SPC ldquoDozardquo
2726
Electrical characteristicsbull Power supply 220 V 50 Hz bull Interfaces RS-232 RS-485 Ethernetbull programmable relay output (SPDT relay)
Alarmbull Sound alarm 80 divide 100 dBA at distance 1 mbull Visual alarm green yellow redbull Connection of the external alarm unit ldquoBASrdquo type
Related monitors and equipmentsbull UDA-1AB particulate monitorbull UDG-1B noble gas monitorbull UDI-1B iodine monitorbull UPPVM air flow parameters monitorbull Sampling and sample separation rack
Air flow parameters monitor rack
Reference standards Nuclear IEC 60761 IEC 61171 IEC 61172 IEC 62302 ISO 2889 EMC IEC 61010 IEC 61000-6-2 Seismic IEC 60980
Sampling and sample separation rack
Continuous monitoring of radioactivity in gaseous effluentsbull Automatic monitoring of the alpha- and beta-
radioactive aerosol noble gas and radioiodine concentrations in the air in ventilation ducts and stacks
bull Monitoring of the flow rate temperature and humidity of the gas flow
bull Separation of gaseous effluent into targeted fractions by means of a two-stage filter
bull Reversion of gas after analysis to the ventilation system
Physical characteristics
Particulate (UDA-1AB)bull Silicon specrometric detectors (2 pcs for measure-
ment and for gamma-background compensation) bull Filter tape types LFAS FSLWbull Tape consumption (when continuous operation)
10 m50 days
Measurement range bull Alpha 10-2 divide 2105 Bqm3 bull Beta 10-1 divide 106 Bqm3
Energy range bull Alpha 30 divide 90 MeV bull Beta 005 divide 30 MeV
Noble gas (UDG-1B)bull silicon detectors (2 pcs for measurement and for
gamma-background compensation)
Measurement range bull 104 divide 6109 Bqm3
Energy range bull 008 divide 30 MeV
Iodine (UDI-1B)bull scintillation detectors CsI(Tl) (2 pcs for measure-
ment and for background compensation)
SKGAV STACK MONITOR
Particulate noble gas and iodine monitors rack
Measurement range bull 37 divide 37105 Bqm3
Energy range bull 015 divide 30 MeV
Air flow parameters (UPPVM)Measurement range bull air flow velocity 1 divide 20 msbull air temperature 0 divide +80 ordmСbull air humidity 10 divide 95
Radiation monitoring system SPC ldquoDozardquo
28 29
CONFIGURATOR SOFTWAREMaintenance and set-up softwarebull Set-up and verify RMS monitorsbull Control testing adjustment and repair of RMS
monitorsbull Monitors measurement results archive receive
and View bull Communication through RS-232
RMS WORKSTATION ndash OPERATOR CONSOLEOrganization of interaction of the RMS Server and Monitors
Single monitor console includes vandal-proof key-board amp UPS
Reference standard IEC 61559-1 IEC 61559-2
RMS SOFTWAREData acquisition storing and visual representation RMS monitors measurement resultsbull Ethernet IEEE 8023 networkbull Clientserver architecturebull TCPIP protocolbull Oracle based Data Basebull Supremal by means InSat MasterSCADA
Radiation monitoring system SPC ldquoDozardquo
30 31
Delivery setComposition and modification depend on the tasks to be solved using the RM Rack
The rack which is an integral part of RM Rack accommodatesbull Monitors UDA-1AB UDG-1B UDG-03D UDI-1B
UDGB-01Tbull DBG-S11D Wide range gamma area monitor
BDMG-101 High range gamma area monitor UDMN-100 Neutron area monitor BDRG-52R High range gamma area monitor
bull BI-2 Remote display amp alarm unitbull Pump unit BN-01bull Data processing and transmission unit BOP-1Mbull External alarm BAS or BAS-1sbull Equipment of sampling line (flow meters ball
valves filter holder piping solenoid valve)bull Switchboard (intended for switching of all equip-
ment and transfer of data to the upper level via the unified communication channel)
RM RACK RADIATION MONITORING RACK
The radiation monitoring rack (RM Rack) is designed for continuous monitoring of radiation parameters in premises and technological systems at nuclear facil-ities RM Rack can be used as a structural element of the lower-level of RMS at nuclear power plants and other nuclear facilities that involved in obtaining processing use and storage of radioactive materials
FeaturesContinuous automatic monitoring of the alpha- and beta- radioactive aerosol beta-emitting radioactive gases and radioiodine concentrations in the working air and in the air in stacks and others radiation parameters in the facilities
The stand providesbull Primary processing storage and transmission of
measured and related data into the information channel based on the Ethernet IEEE 8023 inter-face (TCPIP protocol)
bull Transfer of required data to the location where the equipment is installed via technological channels based on RS-232 interface
bull Generation of audible and visual warning alarm signals when the preset thresholds are exceeded
bull Display of received data on the LCD
Radiation monitoring system SPC ldquoDozardquo
32 33Reference standards IEC 60860 ANSIANS-83 ISO 7753
Purposebull Detection and recording of criticality accident
(CA) by measuring the absorbed dose rate of gamma-neutron radiation in the premises of monitored object its comparison with a threshold value and generation of audible and visual signals
bull Automatic collection processing storage and display of measurement data and related infor-mation as visual and graphical representation for operators of nuclear safety service
Functions of the systembull Detection and recording of CA events by con-
tinuous measurement of absorbed dose rate of gamma radiation comparison of measured values with preset thresholds generation of signals to activate the alarm
bull Activation of audible visual alarmbull In the event of CA turning on warning signals
ldquoDO NOT ENTERrdquo at illuminated information pan-els placed at the entrances to the controlled area
Featuresbull Data can be transferred to external data commu-
nication channel using RS-485 interface (DiBus data exchange protocol)
bull Automatic self-testing of detection units BR-04D with display of information about the type of fault
bull Possibility for connecting additional a detection and alarm units
bull Ability to function in general regardless of the functioning of components within the agreed scope of nuclear safety tasks
bull Radiation hardness up to 100 Gy
SRKS-01DCRITICALITY ACCIDENT ALARM SYSTEM
Features of softwarebull Collection of information via RS-485 network
displaying it on the PC monitor transmission to remote users archiving and storage
bull Status monitoring and display of values measured by BR-04D and DBG-S11D in locations as per layout of premises
bull Access to archived data with possibility to gener-ate reports for periods determined by operator
bull Maintenance and archiving of a log of dosimetric measurements data and events along with their time stamps
bull Possibility to transfer data to external users via Ethernet network for integrating of CA into higher level systems
Basic complete setLower level bull Control unit with power supplybull BR-04D detection unitsbull BZS-01D audible alarm unitsbull BSS-01D visual alarm unitsbull SIT-01D illuminated warning signsbull PBZ panels for muting audible alarmbull Network communication module
Additional lower layer devicesbull DBG-S11D wide range gamma area monitor
Upper layer bull CDP central display panelbull Service workstation
RS-485
RS-485
RS-4
85
Audible alarm units BZS-01D
Illuminated warning signs SIT-01D
Detection units BR-04D
Network communication
moduleDBG-S11D wide range gamma area monitor
Panels for muting audible alarm
Control unit with power supply
Visual alarm units BSS-01D
RS-485
RS-485
RS-4
85
Audible alarm units BZS-01D
Illuminated warning signs SIT-01D
Detection units BR-04D
Network communication
moduleDBG-S11D wide range gamma area monitor
Panels for muting audible alarm
Control unit with pow-er supply
Visual alarm units BSS-01D
RS-485
RS-4
85
Audible alarm units BZS-01D
Illuminated warning signs SIT-01D
Detection units BR-04D
Network communication
moduleDBG-S11D wide range gamma area monitor
Panels for muting audible alarm
Control unit with power supply
Visual alarm units BSS-01D
RS-485
RS-485
RS-4
85
Audible alarm units BZS-01D
Illuminated warning signs SIT-01D
Detection units BR-04D
Network communication
moduleDBG-S11D wide range gamma area monitor
Panels for muting audible alarm
Control unit with power supply
Visual alarm units BSS-01D
Ethernet
Central display panel Service workstation
RS-485
RS-485
RS-4
85
BZS-01D audible alarm units
SIT-01D illuminated warning signs
BR-04D detection units
Network communication
moduleDBG-S11D wide range gamma area monitor
PBZ panels for muting audible alarm
Control unit with power supply
BSS-01D visual alarm units
Radiation monitoring system SPC ldquoDozardquo
34 35
ldquoBREEZErdquoHIGH-VOLUME AIR SAMPLER
Physical characteristicsbull Measurement range of air flow rate
250 divide 1200 m3hbull Continuous operation time not less than 24 h
Filter materialsbull High-purity glass fiberbull Pure quartz or cellulosebull Filter fabric FPP-15-15
Electrical characteristicsPower supply bull 220380 V 50 Hz
Interfaces bull RS-485bull Ethernetbull GSMGPRS (option)
Environmental characteristicsTemperature range bull minus 40 divide + 40 ordmC
Relative humidity limit at 35 ordmC bull 95
Atmospheric pressure range bull 840 divide 1067 kPa
Versionsbull Standalone unit bull Part of Environmental Radiation Monitoring
System (ERMS)
Type of detection unitsbull Beta block BDZB-100Lbull DBG-S11D wide range gamma area monitorbull Scintillation spectrometric block
The motor of Air Sampler is controlled by an electronic flow sensor that detects changes in the operators pre-set flow rate caused by changes in temperature barometric pressure and pressure drop due to dust loading on filter media It compensates for these changes by adjusting the motor speed to maintain the pre-set flow ratebull Measurement of parameters of ionizing radiation bull Standalone mode of operation or as the part
of Environmental Radiation Monitoring System (ERMS)
Purposebull Environmental Radiation Monitoring System
(ERMS) in the control and buffer areas of the radia-tion and nuclear facilities
Referencesbull Since the year 2000 the system is successfully
operating the ERMSs at 8 Russian nuclear power plants (about 180 monitoring stations)
bull Since the year 2005 the ERMS is operating in the Moscow (about 40 monitoring stations)
bull Since the year 2005 the regional ERMS is under operation in several Russian Federation regions
Basic complete setMonitoring stations bull Data processing and transmission unit BOP-1TA bull Gamma area monitor DBG-S11D
Central data processing station (CDPS)bull Data processing and transmission unit BOP-1TAbull Server
By requestbull Emergency Response and Crisis Management
Centers for enterprisesbull Regional Emergency Response and Crisis Manage-
ment Centersbull rdquoBreezerdquo High-Volume Air Samplerbull Mobile lab with gamma-survey system rdquoGammandash
sensorrdquo
ldquoATLANT-MrdquoENVIRONMENTAL RADIATION MONITORING SYSTEM
Monitoring system for the continuous radiation monitoring of territories and facilities with the data transmission GSMGPRS network
Data transmission bull GSMGPRS
Power supply bull 220 V 50 Hz
Continuous autonomous operation (at 20 ordmC)bull From built-in battery not less than 5 hoursbull From external battery not less than 24 hours
Operation temperature bull Minus 40 divide +50 ordmC
Operation humidity bull Up to 98
Protection bull IP65
Reference standards Nuclear IEC 61017-11991 IEC 61017-21994
36
Radiation Monitoring Equipment
bull Localization of radioactive contaminationsbull Database with dose rate contaminations
spectra measurement date amp time coordi-nates
bull Work as part of mobile laboratory or as part of Environmental Radiation Monitoring System with real-time data transfer
Physical characteristicsDetector bull Scintillation NaI (Tl) GM counters
Measurement rangebull 01 ndash 107 μSvh
Energy range bull 005 ndash 3 MeV
Operation temperature range bull minus 10 divide +50 ordmС
Electrical characteristics bull Power supply 220 V 50 Hz
ldquoGAMMAndashSENSORrdquoGAMMA-SURVEY SYSTEM
SPC ldquoDozardquoRadiation monitoring equipment
38 39
AREA MONITOR ldquoFREGATrdquoArea Monitor ldquoFregatrdquo is designed for building rela-tively simple and inexpensive radiation monitoring systems at such facilities as radionuclide sources storage areas isotope products warehouses nuclear medicine departments PET centers calibration laboratories where sources of ionizing radiation are used etc
Small scale automated radiation monitoring systems built with ldquoFregatrdquo components featuring audible and visual alarms are matched suitable to meet the regulatory radiation safety requirements
Area monitor ldquoFregatrdquo requires virtually no adjust-ment it is simple and convenient for installation and operation
BPI-1D LOCAL DISPLAY UNIT
Display of monitored parameters values received from external measuring devices
Purposebull Processing and display of values of monitored
parameters on information panel bull Comparison of values of monitored parameters
with thresholdsbull Transfer of monitored parametersrsquo values to
networkbull Generation of alarm in case of exceeding of preset
thresholds including external alarm devices
FeaturesTesting the unit and connected devicesbull Visually on the panelbull Using adjustment software when connected to
PC via USB
Automatic self-testing
The panel displays the following informationbull Diagnostic information about the status of con-
nected devicesbull Current date and timebull Values of measured parametersbull Position of measured values with respect to the
thresholds in the form of scales with green yellow and red zones
bull Time history (trend) for each measured value
Physical characteristicsTemperature range bull minus 10 divide + 50 ordmC
Maximum number of connected devicesbull measuring devices 15bull external audible and visual alarm 15
Display diagonal bull 152 cm (6)
Electrical characteristicsbull Interfaces RS-485bull Power supply 220 V 50 Hz 12 divide 24 V
Mechanical characteristicsbull Protection index IP54bull Paint decontaminable
Overall dimensions weightbull 296x248x118 mm 5 kg
DBG-S11D wide range gamma area monitor
UDMN-100 neutron area monitor
Ethernet RS-485
UDKS-100 gamma and X-ray area monitor
BPI-1D Local display unit
BAS-2 ldquoMicrordquo external visual alarm
BZS-2 ldquoMicrordquo external audible alarm
ldquoImpulsrdquo external display unit
Service workstation
Illuminated warning signs
SPC ldquoDozardquoRadiation monitoring equipment
4140
Continuous automatic monitoring of the gamma- X-ray ambient dose equivalent rate
Physical characteristicsbull Detector tissue-equivalent plastic scintillator
Oslash 45times20 mm
Measurement range bull Dose rate measurement range 01 μSvh divide 1 Svh bull Energy range 0015 divide 10 MeV
Mechanical characteristicsbull Protection index IP65bull Paint decontaminable
Overall dimensions weightbull Oslash72times265 mm 15 kg
UDKS-100 GAMMA AND X-RAY AREA MONITOR
UDMN-100 NEUTRON AREA MONITOR
Physical characteristicsbull detector ndash scintillator ZnS(Ag) Li-6
Measurement range bull 01 μSvh divide 01 Svh
Energy range bull 0025 eV divide 100 MeV
Temperature range bull minus 45 divide +50 ordmC
Electrical characteristicsbull Interfaces RS-485
Mechanical characteristicsbull Protection index IP 65bull Paint decontaminable
Overall dimensions weight bull 428times258times347 mm 115 kg
Continuous automatic monitoring of the neutron-radiations ambient dose equivalent ratebull Spherical polyethylene moderator Oslash 239 mm
MEASURING UNITS
DBG-S11D WIDE RANGE GAMMA AREA MONITOR
Continuous automatic monitoring of the gamma- ambient dose equivalent rate
Physical characteristicsbull Detector ndash GM counters
Measurement rangebull DBG-S11D 01 μSvh divide 10 mSvhbull DBG-S11D-01 01 μSvh divide 10 Svhbull DBG-S11D-02 01 μSvh divide 100 Svh
Energy rangebull 005 divide 30 MeV
Temperature range bull minus 40 divide +50 ordmC
Electrical characteristicsbull Interfaces RS-485 USB
Mechanical characteristicsbull Protection index IP 68bull Paint decontaminable
Overall dimensions weightbull DBG-S11D Oslash 68times141 mm 065 kg bull DBG-S11D-01 Oslash 68times179 mm 07 kgbull DBG-S11D-02 Oslash 68times179 mm 07 kg
Versionsbull DBG-S11Dbull DBG-S11D-01bull DBG-S11D-02
Reference standards Nuclear IEC 60846 IEC 60532 EMC IEC 61010 IEC 61000-6-2 Seismic IEC 60980
SPC ldquoDozardquoRadiation monitoring equipment
4342
ALARM UNITS
Generation visual signals of the excess of preset thresholds
Physical characteristicsLength of communication cablebull up to 1200 mbull Alarm Visual alarm green yellow red
Electrical characteristicsbull Power supply +12 V
Mechanical characteristicsbull Protection index IP 23
Overall dimensions weight 160times84times41 mm 02 kg
BAS-2 ldquoMICROrdquo EXTERNAL VISUAL ALARM
Generation audible signals of the excess of preset thresholds
Physical characteristicsLength of communication cablebull up to 1200 mbull Audible alarm 80 divide 100 dB at a distance of 1 m
Electrical characteristicsbull Power supply +12 V
Mechanical characteristicsbull Protection index IP 23
Overall dimensions weight 160times84times41 mm 02 kg
BZS-2 ldquoMICROrdquo EXTERNAL AUDIBLE ALARM
Physical characteristicsLength of communication cablebull up to 1200 m
Electrical characteristicsbull Power supply 220 V 50 Hz
Mechanical characteristicsbull Protection index IP 23
Overall dimensions weight bull 330times110times20 mm 05 kg
Physical characteristicsLength of communication cablebull up to 1200 m
Character height bull ldquoImpuls-910-Rrdquo 100 mmbull ldquoImpuls-915-D4Srdquo 150 mmbull ldquoImpuls-927-D4Srdquo 270 mm
Operating temperature rangebull ldquoImpuls-910-Rrdquo 0 divide +50 degCbull ldquoImpuls-915-D4Srdquo ldquo-727-D4Srdquo minus 40 divide +50 degC
Electrical characteristicsbull Power supply 220 V 50 Hz
Mechanical characteristicsProtection index bull ldquoImpuls-910-R IP 44bull ldquoImpuls-915-D4Srdquo ldquo-727-D4Srdquo IP 65
Overall dimensions weight bull ldquoImpuls-910-Rrdquo 400times160times60 mm 3 kgbull ldquoImpuls-915-D4Srdquo 815times250times80 mm 5 kgbull ldquoImpuls-927-D4Srdquo 1250times330times80 mm 5 kg
ILLUMINATED WARNING SIGNS
ldquoIMPULSrdquo EXTERNAL DISPLAY UNIT
SPC ldquoDozardquoRadiation monitoring equipment
4544
Individual threshold setting for each measurement channel
Continuous area and process monitoring
Collect amp display data from two measurement chan-nels (units with RS-485 or analog pulses)
Audible and visual alarms on exceeding preset thresholds or status of connected devices
Individual threshold setting for each measurement channel
Switching on the external alarm or executive devices when any threshold is exceeded
The wide panel displays the following information bull Values of measured parameters as min-1∙cm-2
s-1∙cm-2 μSvhbull Diagnostic information about the status of con-
nected devicesbull Current date and timebull Position of measured values with respect to the
thresholds in the form of scales with green yellow and red zones
bull Time history (trend) for each measured value
Physical characteristics Measurement range bull Count rate up to 107 CPM (170 kHz)
Operating temperature range bull minus 20 divide +50 ordmC
Electrical characteristics bull Power supply 220 V bull Interfaces USB
Mechanical characteristics bull Protection index IP 65 bull Overall dimensions weight 222times164times73 mm
40 kg
UIM-3D AREA MONITOR COUNT RATE METER
Measurement of alpha radiation flux density
Detector unit BDZA-100 (70 cm2) Measurement range 01 divide 104 min-1∙cm-2
Detector unit BDZA-100B (300 cm2) Measurement range 01 divide 2103 min-1∙cm-2
Measurement of beta radiation flux density
Detector unit BDZB-100 (28 cm2) Measurement range 10 divide 105 min-1∙cm-2
Detector unit BDZB-100L (30 cm2) Measurement range 10 divide 104 min-1∙cm-2
Detector unit BDZB-11D (84 cm2) Measurement range 5 divide 15∙104 min-1∙m-2
OPTIONAL PROBESMeasurement of gamma radiation flux density
Detector units BDEG-03 Measurement range 4 divide 2000 s-1∙cm-2
Detector unit UDKG-100 for operation in the rocks ore liquid media and sludge Measurement range 40 divide 8000 s-1∙cm-2
Measurement of the ambient dose equivalent rate
Detector unit DBG-S11D Measurement range 01 μSvh divide 100 Svh
Measurement of neutron radiation ambient dose equivalent rate
Detector unit BDMN-100 Measurement range 01 μSvh divide 01 Svh
SPC ldquoDozardquoRadiation monitoring equipment
46 47Reference standards Nuclear IEC 61526
Measurement of gamma-radiation personal dose equivalent Hp(10)bull Stand-alone dosimeter or composed of dosimetric
system onebull Audible and visual alarmbull Large memory dose accumulation historiesbull Exclusion of unauthorized intervention in dosim-
etry operation
DKG-05D PERSONAL GAMMA DOSIMETER
Physical characteristicsDetectors bull Silicon
Measurement range bull Dose rate 1 μSvh divide 10 Svhbull Dose 01 μSv divide 15 Sv
Energy range bull 005 divide 30 MeV
Electrical characteristicsbull Power supply rechargeable NiMH battery 1
alcaline battery (type AAA)
Operation timebull Till recharging not less 400 hoursbull With one set batteries not less 1000 hours
Mechanical characteristicsOverall dimensions weight bull 47times26times87 mm (with clip) 70 g
Environmental characteristicsbull IP65bull Temperature range minus 20 divide +45 ordmCbull Humidity up to 98 at 35 ordmCbull Shock vibration and drop resistant
Alarmbull Excess of alarm thresholdsbull Warnings of self-test failure and battery discharge bull Audible alarm 80 dB at 40 cmbull Visual alarm blinking LED
Relative equipmentbull One dosimeter charger ZU-1Mbull Chargestorage cassetes KZU-28KZU-56bull ldquoSmart chargingrdquo feature extends battery life timebull DKG-05D reader US-05bull DKG-05D system reader DVS-01D
Reader-PC interfacebull US-05 USB bull DVS-01D Ethernet
KZU-28
Physical characteristicsDetectors bull Silicon Li-6
Gamma measurement range bull Dose rate 1 μSvh divide 10 Svhbull Dose 01 μSv divide 15 Sv
Gamma energy range bull 005 divide 60 MeV
Neutron measurement range bull Dose rate 1 μSvh divide 2 Svhbull Dose 20 μSv divide 15 Sv
Neutron energy range bull 0025 eV divide 20 MeV
Electrical characteristicsPower supply bull Rechargeable NiMH batterybull Operatiion time till recharging not less 200 hours
Mechanical characteristicsOverall dimensions weight bull 47times26times87 mm (with clip) 70 g
Environmental characteristicsbull IP65bull Temperature range minus 20 divide +40 ordmCbull Humidity up to 75 at 30 ordmCbull Shock vibration and drop resistant
Alarmbull Excess of alarm thresholds bull Warnings of self-test failure and battery discharge bull Audible alarm 80 dB at 40 cmbull Visual alarm blinking LED
Relative equipmentbull One dosimeter charger ZU-1Mbull Chargestorage cassetes KZU-28 KZU-56bull ldquoSmart chargingrdquo feature extends battery life timebull DVS-02D reader UZS-01Sbull DVS-02D system reader DVS-01D
Reader-PC interfacebull UZS-01S USB bull DVS-01D Ethernet
UZS-01DReference standards Nuclear IEC 61526
DVS-02D GAMMA-NEUTRON PERSONAL ELECTRONIC DOSIMETER
Measurement of gamma- and neutron radiations personal dose equivalent Hp(10)bull Stand-alone dosimeter or composed of dosimetric
system onebull Audible and visual alarmbull Large memory dose accumulation historiesbull Exclusion of unauthorized intervention in dosim-
etry operationbull Both albedo thermal neutrons and intermediate
fast neutrons registrationbull Usable in the fields of Pu(Be) Po(Be) Cf and other
neutron sources as well as near nuclear reactors without neutron spectrum estimation
SPC ldquoDozardquoRadiation monitoring equipment
48 49
Dosimeters DVG-03D
DVGI-8D NEW PEN-TYPE PERSONAL IONIZATION CHAMBER DOSIMETERS
Measurement of personal dose equivalent Hp(10) of gamma and X-ray radiationbull Hp(10) of continuous and pulsed gamma and
X-ray radiation bull Electronic reader KSU-1bull Dosimeter DVG-03D with electronic ID bull Personal dose histories in the readerrsquos memorybull Readerrsquos connection with PC for database main-
tenance
Physical characteristicsDetector bull Ionization chamber
Measurement range bull 001 mSv divide 25 mSv
Energy range bull 0015 divide 25 MeV
Temperature range bull Reader KSU-1 +10 divide +50 ordmСbull Dosimeter DVG-03D minus 40 divide +50 ordmС
Electrical characteristicsPower supply bull Reader KSU-1 220 V 50 Hz built-in batteries bull Dosimeter DVG-03D four batteries CR 1025 bull Batteries life 3 yearsbull Readers interfaces RS-232USB 20
Mechanical characteristicsOverall dimensions weightbull Dosimeter DVG-03D Oslash 18times126 mm 005 kgbull Reader KSU-1 235times232times125 mm 28 kg
Reference standards Nuclear IEC 62387-1
DKG-02U ldquoARBITERrdquo WIDE RANGE GAMMA-DOSIMETER
Physical characteristicsDetectors bull GM counters
Measurement rangebull Dose-rate 01 μSvh divide 3 Svhbull Dose 1 μSv divide 100 Sv
Energy range bull 005 divide 3 MeV
Electrical characteristicsbull Power supply 2 alcaline batteries (type AA)bull Batteries life not less 200 hours
Mechanical characteristicsOverall dimensions weight bull 152times82times32 mm 03 kg
Environmental characteristicsbull Temperature range minus 20 divide +50 ordmCbull Humidity up to 90 at +25 ordmCbull Shock vibration and drop resistant
Reference standards Nuclear IEC 60846
Measurement of gamma radiation ambient equiva-lent dose H(10) and dose rate H(10)bull Audible signals (clicks) for radiation condition
estimationbull Analog scale for search modebull Audible and visual alarms of the excess of preset
dose and dose rate thresholds bull Shock-resistant water-proof easy decontamina-
tion casebull 100 measurement results memory with date and
time of measurementbull Indication of total dose accumulated during
exploitation time bull Indication of measurement result statistical
uncertainty
SPC ldquoDozardquoRadiation monitoring equipment
50 51
Physical characteristicsDetectors bull GM counter
Measurement rangebull Dose-rate 01 μSvh divide 3 mSvhbull Dose 1 μSv divide 02 Sv
Energy range bull 005 divide 3 MeV
Temperature range bull Minus 20 divide +50 ordmC
Electrical characteristicsbull Power supply 2 alcaline batteries 15 V (type AA)bull Batteries life not less 200 hours
Mechanical characteristicsOverall dimensions weight bull 122times74times29 mm 025 kg
Reference standards Nuclear IEC 60846
DKG-07D ldquoDROZDrdquoGAMMA-DOSIMETER
Measurement of gamma radiation ambient equiva-lent dose H(10) and dose rate H(10)bull Two independent measurement channels dose
and dose ratebull Audible signals (clicks) for radiation condition
estimationbull Continuous measurement with updating meas-
urement resultbull Measurement result can be obtained with any
desired statistical uncertainty (error)bull Automatic restart when radiation level sharply
changesbull Indication of statistical uncertainty (error) during
measurement process
Continuous measurement with updating measure-ment result
Automatic restart when radiation level sharply changes bull Gamma dose H(10) and dose-rate H(10) meas-
urementbull Beta and gamma contamination surveybull Indication of statistical uncertainty during the
measurementbull Continuous measurement with accuracy increas-
ing with time bull Automatic restart triggered by change of gamma
dose-ratebull Compensation of gamma count rate while meas-
uring beta radiationbull Indication of battery charge levelbull Audible signal of the excess of preset threshold
Physical characteristicsDetectors bull GM counter
Measurement range bull Dose-rate 01 microSvh divide 20 mSvhbull Dose 1 microSv divide 100 Svbull Beta flux density (for Sr-90+Y-90)
10 divide 105 cm-2 min-1
Energy range bull Gamma 005 divide 3 MeVbull Beta 01 divide 3 MeV
Temperature range bull Minus 20 divide +50 ordmC
MKS-15D ldquoSnegirrdquo backside
MKS-15D ldquoSNEGIRrdquoMULTI ndash PURPOSE RADIATION SURVEY METER
Reference standards Nuclear IEC 60846 IEC 60325
Electrical characteristicsbull Power supply 2 alcaline batteries (type AA)bull Battery life not less 400 hours
Mechanical characteristicsOverall dimensions weight bull 124times72times35 mm 035 kg
SPC ldquoDozardquoRadiation monitoring equipment
52 53
Physical characteristicsDetectorbull GM counter
Measurement range bull 01 μSvh divide 20 mSvh
Energy range bull 005 divide 30 MeV
Threshold setting range bull 03 μSvh divide 20 mSvh
Step change of the thresholdbull In the range 03 divide 10 μSvh with the step
001 μSvhbull In the range 10 divide 100 μSvh with the step
01 μSvhbull In the range 100 divide 2000 μSvh with the step
10 μSvh
Electrical characteristicsPower supply bull 220 V 50 Hz bull Relay output
Mechanical characteristicsProtection index bull IP 40
Overall dimensions weight bull 226times120times75 mm 07 kg
Alarmbull Sound alarm 80 divide 100 dBA at distance 1 mbull Visual alarm redbull Connection of the external alarm signaling unit
Reference standards Nuclear IEC 60846 IEC 60532
Continuous automatic monitoring of the ambient dose equivalent rate bull Measurement of gamma dose rate H(10)bull Audible and visual alarm signals for preset
thresholdsbull Switching on the external signaling or executive
devices
SRPS-05D GAMMA MONITOR
Measurement ofbull Gamma and X-ray personal dose equivalent
Hp(10)bull Neutron personal dose equivalent Hp(10)bull Lens dose equivalent Hp(3)bull Skin dose equivalent Hp(007)bull TLD reader day-to-day tests using built-in LEDbull No needs nitrogen for heating
Physical charachteristicsDetectors bull 7LiF Mg Ti (gamma beta)bull 6LiF Mg Ti (neutron)
Gamma and X-ray Hp(10) Measurement range bull 500 μSv divide 10 Sv
Energy range bull 0015 divide 30 MeV
Neutron Hp(10)Measurement range bull 01 mSv divide 100 mSv
Energy range bull 0025 eV divide 10 MeV
Beta and photons Hp(007) Hp(3) Measurement range bull 2 mSv divide 100 Sv
Energy range bull Beta 025 divide 35 MeVbull Photons lt15 keV
Mechanical characteristicsDosimeters overall dimensions weight bull Gamma Hp(10) DTL-2 holder - 62times26times16 mm
16 gbull DTU holder - 42times28times18 mm 8 gbull Lens Hp(3) face skin Hp(007) Oslash 32times16 mm 9 gbull Finger skin Hp(007) 90times20times2 mm 1 gbull Neutron gamma Hp(10) 48times40times20 mm 30 g
Reference standards Nuclear IEC 61066
DTL-2 DTU-2
MKD (A-type) DVNG-M
DOZA-TLD MULTIPURPOSE TLD SYSTEM
SPC ldquoDozardquoRadiation monitoring equipment
54 55
Continuous and pulsed gamma and X-ray dose H(10) and dose-rate measurementbull Alpha beta and gamma contamination surveybull Neutron dose H(10) and dose-rate measurementbull Gamma radiation flux density in boreholes and
liquid media measurement
Electrical characteristicsPower supply bull UIK-05 four C-size batteriesbull UIK-05-01 rechargeable batterybull UIK-06 rechargeable battery
Interfaces bull RS-232bull USB (via adapter)
bull Detector type automatic determination and corre-sponding measurement modes selection
bull Alarm threshold settings ndash for dose dose-rate alpha and beta contaminations
bull ldquoDetectrdquo and ldquoLocaterdquo modes for survey probes
Reference standards Nuclear IEC 60846 IEC 60325 IEC 61005 IEC 62363
Case
UIK-06 control unit165times78times48 mm 03 kg
DKS-96UNIVERSAL RADIATION SURVEY METER
UIK-05 control unit202times86times90 mm 10 kg
BDZA-96
BDZA-96B
BDZA-96M
BDZA-96S
BDZA-96T
EXTERNAL PROBES ALPHAALPHA BDZA-96Detector bull ZnS(Ag) 70 cm2
Measurement range (for Pu-239)bull 01 divide 104 min-1cm-2
Overall dimensions weightbull Oslash 130times240 mm 11 kg
ALPHA BDZA-96BDetector bull ZnS(Ag) 300 сm2
Measurement range (for Pu-239)bull 01 divide 2103 min-1cm-2
Overall dimensions weightbull Oslash 230times290 mm 40 kg
ALPHA BDZA-96MDetector bull ZnS(Ag) 10 сm2
Measurement range (for Pu-239)bull 01 divide 105 min-1cm-2
Overall dimensions weightbull Oslash 65times240 mm 09 kg
ALPHA BDZA-96SDetector bull ZnS(Ag) 30 сm2
Measurement range (for Pu-239)bull 01 divide 5104 min-1cm-2
Overall dimensions weightbull Oslash 90times240 mm 10 kg
ALPHA BDZA-96TDetector bull Silicon 5 сm2
Measurement range (for Pu-239)bull 01 divide 106 min-1cm-2
Overall dimensions weightbull Oslash 50times60 mm 015 kg
SPC ldquoDozardquoRadiation monitoring equipment
56 57
BETA BDZB-96Detector Scintillator 28 сm2
Measurement range (for Sr-90+Y-90)bull 10 divide 105 min-1cm-2
Energy rangebull 03 divide 30 MeV
Overall dimensions weightbull Oslash 90times230 mm 09 kg
BETA BDZB-99Detector bull GM counter 30 сm2
Measurement range (for Sr-90+Y-90)bull 20 divide 104 min-1см-2
Energy rangebull 012 divide 30 MeV
Overall dimensions weightbull Oslash 88times80 mm 04 kgbull Telescopic pole length 07 m
BETA BDZB-96BDetector bull GM counter 80 сm2
Measurement range (for Sr-90+Y-90)bull 3 divide 104 min-1сm-2
Energy rangebull 012 divide 30 MeV
Overall dimensions weightbull 150times200times110 mm 15 kg
BETA BDZB-96Sbull Detector GM counter 15 сm2
Measurement range (for Sr-90+Y-90)bull 10 divide 3104 min-1cm-2
Energy rangebull 012 divide 30 MeV
Overall dimensions weightbull Oslash 65times65 mm 03 kgbull Telescopic pole length 07 m
BDZB-96
BDZB-99
BDZB-96B
BDZB-96S
EXTERNAL PROBES BETA
GAMMA BDKS-96BDetector bull Tissue-equivalent scintillator Oslash 45times20 mm
Measurement rangebull Dose rate H(10) 01 μSvh divide 1 Svhbull Dose H(10) 01 μSv divide 10 Sv
Energy rangebull 0015 divide 10 MeV
Overall dimensions weightbull Oslash 60times250 mm 085 kg
GAMMA AND BETA BDKS-96SDetector bull Double GM counters
Measurement rangebull Gamma dose rate H(10) 01 μSvh divide 1 mSvhbull Gamma dose H(10) 01 μSv divide 10 Svbull Beta 10 divide 3104 min-1cm-2
Energy rangebull Gamma 005 divide 3 MeVbull Beta 012 divide 3 MeV
Overall dimensions weightbull Oslash 80times80 mm 035 kgbull Telescopic pole length 07 m
GAMMA BDMG-96Detector bull GM counters
Measurement rangebull Dose rate H(10) 01 μSvh divide 10 Svhbull Dose H(10) 01 μSv divide 10 Sv
Energy range bull 005 divide 3 MeV
Overall dimensions weightbull 40times250 mm 05 kgbull Telescopic pole length 07 m 4 m (by request)
EXTERNAL PROBES GAMMA
BDKS-96B
BDMG-96
BDKS-96S
SPC ldquoDozardquoRadiation monitoring equipment
58 59
GAMMA-SEARCH BDVG-96Detector bull Scintillator NaI(Tl) Oslash 63times63 mm
Measurement rangebull Flux density measurement range 4 divide 2000 s-1cm-2
bull Dose rate H(10) for Cs-137 01 divide 30 μSvhbull Sensitivity for Cs-137 3000 (pulsess-1)( μSvh-1)
Overall dimensions weightbull Oslash 88times400 mm 20 kgbull Modular pole length 16 m
GAMMA-SEARCH BDPG-96Detector bull Scintillator NaI(Tl) Oslash 25times40 mm
Measurement rangebull Flux density measurement range 10 divide 8000 s-1cm-2
bull Dose rate H(10) for Cs-137 01 divide 100 μSvhbull Sensitivity for Cs-137 500 (pulsess-1)( μSvh-1)
Overall dimensions weightbull 50times190times480 mm 10 kgbull Telescopic pole length 07 m
GAMMA-SEARCH BDPG-96MDetector bull Scintillator NaI(Tl) Oslash 18times30 mm
Measurement rangebull Flux density measurement range 10 divide 24000 s-1cm-2
bull Dose rate H(10) for Cs-137 01 divide 300 μSvhbull Sensitivity for Cs-137 200 (pulsess-1)( μSvh-1)
Overall dimensions weightbull Oslash 35times320 mm 05 kgbull Telescopic pole length 07 or 38 m
EXTERNAL PROBES GAMMA
BDVG-96
BDPG-96M
BDPG-96
EXTERNAL PROBESGAMMA BDKG-96 STAINLESS STEEL CASING FOR GEOLOGIC APPLICATIONS WELL LOGGINGDetector bull Scintillator NaI(Tl) Oslash 18times30 mm
Measurement rangebull Flux density measurement range 10 divide 105 s-1cm-2
bull Dose rate H(10) for Cs-137 5 divide 2104 μRhbull Sensitivity for Cs-137 200 (pulsess-1)( μSvh-1)
Overall dimensions weightbull Oslash 38times535 mm 36 kgbull Cable length 10 divide 1000 m
NEUTRON BDMN-96Detector bull Scintillator with ZnS(Ag)
Measurement rangebull Dose rate H(10) 01 μSvh divide 01 Svhbull Dose H(10) 01 μSv divide 10 Sv
Energy range bull 0025 eV divide 10 MeV
Overall dimensions weightbull Detector Oslash 54times200 mm 08 kgbull Moderator Oslash 245 mm 73 kg
NEUTRON-SEARCH BDKN-96Detector bull He-3 counter in polyethilene moderator
Measurement rangebull Dose rate H(10) for Pu-Be 01 μSvh divide 01 Svhbull Dose H(10) for Pu-Be 01 μSv divide 10 Sv
Energy range bull 0025 eV divide 14 MeV
Overall dimensions weightbull 295times142times100 mm 225 kg
BDKG-96M
BDMN-96
BDKN-96
SPC ldquoDozardquoRadiation monitoring equipment
60 61
bull No gas supply neededbull Clothing control detachable right hand detector bull Alpha detector optional connection bull Numeric and color (red green) indication of
control resultsbull LED sensor of hand-foot positioning for start of
measurementbull Automatic compensation of gamma background
and contamination of detectorbull Audible alarm signals of the excess of preset
thresholdsbull Measurement value indication min-1cm-2 or
Bqсm2
Reference standards Nuclear IEC 61098
RZB-05D HAND-FOOT-CLOTHING MONITOR
Physical characteristicsDetectors bull Gamma beta - GM countersbull Alpha - scintillatior ZnS(Ag)
Detecting nuclidesbull Alpha Pu-239 U-234 U-238bull Beta Sr-90+Y-90 F-18 Cs-137 Co-60 Tс-99 O-15
N-13 Sr-89 C-11 I-131 Na-22 Ru-106+Rh-106 Tl-204
bull Gamma Tc-99m I-123
Efficiencybull Alpha
Pu-239 40 U-234 25U-238 15
bull Beta Sr-90 +Y-90 40
Measurement range bull Alpha 1 divide 103 min-1cm-2 bull Beta 10 divide 103 min-1cm-2
bull Gamma 5103 divide 5106 min-1cm-2
Energy range bull Alpha 30 divide 80 MeV bull Beta 008 divide 35 MeV bull Gamma 005 divide 30 MeV
Operation temperature range bull Minus 10 divide +50 ordmС
Electrical characteristicsbull Power supply 220 V 50 Hz
Mechanical characteristicsOverall dimensions weight bull 740times750times1180 mm 45 kg
Versionsbull Withwithout alpha detectorbull Indication (min-1cm-2 ) or (Bqсm2)bull Detectors overall dimensions smbull Hand 178 х 235bull Foot 185 х 436
Whole body contamination monitor RZBA-04-04Mbull No gas supply neededbull Compensation for background gamma radiation
and contamination of detector unitsbull Individual threshold setting for each measure-
ment channelbull Visible and audible alarms ldquoCONTAMINATIONrdquo and
ldquoCLEANrdquo bull Indication of contaminated body parts on the
panel with image of the bodybull Optional remote alpha-detector
Physical characteristicsDetectors bull Beta - GM counters scintillatorsbull Alpha - scintillatior ZnS(Ag)
Measurement range bull Beta 5 divide 15000 min-1cm-2
bull Alpha 01 divide 10000 min-1cm-2
Energy range bull Beta 015 divide 25 MeV bull Alpha 40 divide 56 MeV
Operation temperature range bull +5 divide +50 ordmС
Electrical characteristicsPower supply bull 220 V 50 Hz
Interfaces bull RS-232bull RS-485
Mechanical characteristicsOverall dimensions weight bull 2650times940times930 mm 310 kg
Versionsbull Withwithout alpha detectorbull Indication (min-1cm-2 ) or (Bqсm2)
Reference standards Nuclear IEC 61098
RZBA-04-04MWHOLE BODY CONTAMINATION MONITOR
SPC ldquoDozardquoRadiation monitoring equipment
62 63
RZA-05DALPHA HAND-MONITOR
bull No gas supply needed bull Numeric and color (red green) indication of
control resultsbull LED sensor of hand- positioning for start of
measurementbull Audible alarm signals of the excess of preset
thresholdsbull Measurement value indication min-1cm-2 or
Bqсm2
Physical characteristicsDetectors alpha - scintillatior ZnS(Ag)
Efficiencybull Pu-239 20 bull U-234 14bull U-238 8
Measurement range bull 05 divide 105 min-1cm-2
Energy range bull 41 divide 90 MeV
Operation temperature range bull minus 10 divide +50 ordmС
Electrical characteristicsPower supply bull 220 V 50 Hz
Mechanical characteristicsOverall dimensions weight no more bull 740times1400times1450 mm 70 kg
Reference standards Nuclear IEC 61098
bull Simultaneous measurement of alphabeta activi-ties in the sample
bull Active shielding anti-coincidence background subtraction using GM counters
bull Lead shielding 30 mm
UMF-2000 LOW LEVEL ALPHA- BETA- COUNTER
Physical characteristicsDetectors bull Silicon specrometric detector 500 or 1000 mm2
Measurement range bull Alpha 001 divide 1000 Bq bull Beta 01 divide 3000 Bq
Energy range bull Alpha 35 divide 80 MeV bull Beta 005 divide 35 MeV
Electrical characteristicsPower supply bull 220 V 50 Hz
Interfaces bull RS-232bull USB
Mechanical characteristicsOverall dimensions weight bull 337times286times190 mm 22 kg
Versionsbull Detector area 500 mm2
bull Detector area 1000 mm2
UMF-2000 Detector area 1000 mm2
UMF-2000 Detector area 500 mm2
SpectraDec software for alpha-spectrometric measurements
SPC ldquoDozardquoRadiation monitoring equipment
64 65
DRK DOSE AREA PRODUCT METER
DRK-1bull Diagnostic reference level (DRL) of patients
determinationbull Suitable for all basic types of x-ray machines
Physical characteristicsDetector bull Plane-parallel ionization chamber
Measurement range bull 1 divide 104 cGycm2
Electrical characteristicsPower supply bull 220 V 50 Hz
DRK-1M-CTbull Measuring of dose length product
Physical characteristicsDetector bull Pencil Ionization Chamber
Measurement rangebull 05 divide 109 microGym
DRK-1Mbull Measuring of air kerma on sectional area of the
X-ray beam productbull Measuring of air kerma rate on area productbull Measuring of air kerma ratebull Measuring of air kerma
Physical characteristicsDetector bull Plane-parallel ionization chamber
Measurement rangebull 01 divide 109 microGym2
bull 06 divide 6104 microGym2cbull 30 divide 9105 microGycbull 30 divide 9991011 microGyReference standard IEC 60580 2003
bull Measurement of strontium-90 in the foodstuffs agricultural products etc
bull Measurement of gross beta activity in samplebull Self tests using built-in LED
ldquoPROGRESS-BETArdquo SCINTILLATION BETA SPECTROMETER
Physical characteristicsDetector bull Plastic scintillator Oslash70x10 mm
Sample bull Plate Oslash70 mmbull Weight up to 15 g
Energy range bull 02 divide 30 MeV
Minimum detectable activity of Sr-90 in a 10 g sample on a standard planchet Bqsamplebull In case of absence of K-40 in the sample 01 Bqbull In case the activity of K-40 till 5 Bqg 05 Bq
Electrical characteristics Interface bull USB
Mechanical characteristicsWeight bull No more 50 kg
Complete setBasic complete setbull Detector unit with plastic scintillator integrated
power supply amplifier ADC bull Lead shielding bull ldquoProgressrdquo software bull Сheck source for energetic calibration (Sr-90-Y-90) bull Planchet Oslash 70 mm (5 items) bull Sample dencification device bull Procedure manual for measurement of radio-
nuclidesrsquo activity using the scintillation beta spec-trometer ldquoProgressrdquo
Optional equipment and servicebull Personal computer and printer bull Calibrations for radionuclides not included in the
main library of radionuclides
Progress-Beta
Reference standards IEC 61562
SPC ldquoDozardquoRadiation monitoring equipment
66 67
bull Measurement of gamma activity in foodstuffs soil samples and others environmental objects
bull Identification of radionuclides in the sample bull Automatic correction for sample density bull Self-tests using built-in LED
ldquoPROGRESS-GAMMArdquoSCINTILLATION GAMMA SPECTROMETER
Physical characteristicsDetector bull NaI (Tl) Oslash63times63 mm
Validated measurement geometries bull Marinelli beakers (1 liter) Petri dishes (Oslash90 mm)
etc
Energy range bull 02 divide 30 MeV
Minimum detectable activity Bqsamplebull Cs-137 3 Bqbull Th-232 7 Bqbull Ra-226 8 Bq bull К-40 40 Bq
Electrical characteristics Interface bull USB
Mechanical characteristicsWeight bull No more 120 kg
Complete setBasic complete setbull Scintillation detector unit with NaI (Tl) detector
with integrated power supply amplifier and ADC bull Lead shielding 50 mm bull ldquoProgressrdquo software bull Сheck source for energy calibration (Cs-137 +
K-40)bull Marinelli beakers - 1 liter (5 items) bull Petri dishes Oslash 90 mm (5 items) bull Procedure manual for measurement of activity
of radionuclides using the scintillation gamma spectrometer ldquoProgressrdquo
Optional equipment and servicebull Kit for radon measurements including calibration
of ldquoIC-63rdquo geometry for counting the charcoal samples
bull Personal computer and printer bull Calibrations for user defined geometries bull Calibrations for radionuclides not included in the
main library of radionuclides
Progress-Gamma
Reference standards IEC 61563
ldquoPROGRESS-G(P)rdquoPORTABLE SCINTILLATION GAMMA SPECTROMETERbull Field measurements of gamma activity in environ-
mental objects without sampling (4π geometry)bull Laboratory measurement of gamma activity in
foodstuffs soil samples and others environmental objects
bull Identification of radionuclides in the sample bull Automatic correction for sample densitybull Tests using built-in LED
Physical charachteristicsDetector bull NaI (Tl) Oslash45times50 mmbull Lead shielding 20 mm
Validated measurement geometries bull Marinelli beakers (05 liter) Petri dishes (Oslash90 mm)
etc
Energy range bull 02 divide 30 MeV
Minimum detectable activity in 05-litre Marinelli beaker bull Cs-13710 Bqkgbull К-40100 Bqkgbull Ra-22618 Bqkg bull Th-23216 Bqkg
Minimum detectable activity in 30 min (4π geometry) bull Cs-137 2 Bqkgbull К-40 30 Bqkgbull Ra-226 4 Bqkg bull Th-232 3 Bqkg
Electrical characteristicsPower supply bull Rechargeable batterybull 220 V 50 Hz
Interface bull USB RS-232
Weight bull No more than 60 kg
Complete setBasic complete setbull Scinttillation detector unit with NaI(Tl) bull ldquoProgressrdquo softwarebull Сontrol unit ldquoSputnikrdquo for aquisition and analisys
of spectra with built-in memory for spectral databull Casebull Lead shielding (2 cm) for laboratory usebull 05-litre Marinelli beakers ndash 5 itemsbull Na-22 check sourcebull Power adapter BPS-01bull Operation manualbull Procedure manual for measurement of activity
of radionuclides using the scintillation gamma spectrometer ldquoProgressrdquo
Optional equipment and servicebull Kit for radon measurements with charcoalbull Built-in dose rate meterbull Additional memory (RAM) for storage of 64
spectrabull Additional power adapterbull Notebook and printer
Progress-Gamma
Reference standards IEC 61563
SPC ldquoDozardquoRadiation monitoring equipment
68 69
Physical characteristicsDetectorbull Scintillation detector ZnS (Oslash 60 mm)
Samplebull Thin sample - diameter up to 70 mm bull Preparation technique - electro-depositionbull Thick sample - diameter 70 mm weight
200300 mg bull Preparation technique - application of powders
(prepared by radiochemical concentration by water evaporation or by pounding of mineral samples) onto a planchet with the help of spirit
Energy rangebull 15 divide 8 MeV
Minimum detectable activitybull Thin samples no more than 910-3 Bqsamplebull Thick samples no more than 180 Bqkg
Mechanical characteristicsOverall dimensions weightbull 195times120times210 mm 34 kg
Complete setBasic complete setbull Alpha radiometer ldquoProgress-ARrdquobull Check source (uranium isotopes)
Set of accessoriesbull Procedure manual for measurements of radi-
oactivity using scintillation alpha radiometer ldquoProgress-ARrdquo
bull ldquoProgressrdquo software
ldquoProgress-ARrdquo
bull Measurement of gross activity of alpha emitting radionuclides in thin samples
bull Measurement of gross activity of alpha emitting radionuclides in thick samples
bull Measurement of activity deposited on aerosol filters
ldquoPROGRESS-ARrdquoALPHA RADIOMETER
Several fixed positions of the detector enable to perform measurements in various geometries and to estimate the content ofbull Cs-137 in the whole bodybull I-131 in thyroidbull Co-60 Cs-137 Mn-54 Cr-51 in lungsbull Database for storage of measurement data and
resultsbull Uncertainty calculations based on measurement
databull Self tests using built-in LED
ldquoPROGRESSrdquo WHOLE BODY COUNTER
Physical characteristicsDetectorbull scintillation detector NaI (Tl) Oslash63times63 mm
Energy rangebull 02 divide 28 MeV
Minimum detectable activitybull By Cs-137 in the whole body - 1200 Bqbull By I-131 in thyroid - 100 Bqbull By Co-60 Cs-137 Mn-54 Cr-51 in lungs - 200 Bq
Mechanical characteristicsWeight bull No more than 120 kg
Complete setBasic complete setbull Collimator with rotator and holderbull Detector with incorporated ADCbull Patient chair and table for collimatorbull Check source Na-22bull Procedure manual for lifetime measurement of
gamma-emitting radionuclidesrsquo activity in human body using the gamma-spectrometer of human radiation ldquoProgressrdquo
bull laquoProgressraquo software
Optional equipment and servicebull Program of internal radiation committed internal
radiation effective dose calculation by the stand-ard model
bull Background phantombull Personal computer and printer
Collimator with rotator and holder
SPC ldquoDozardquoRadiation monitoring equipment
70 71
bull Categorization of wastes for the purpose of fur-ther processing including wastes with unknown radionuclide composition
bull Measurements during the incoming waste inspec-tion (accepting for storage disposal)
bull Certification of unconditioned and conditioned wastes in closed containers without opening them (at nuclear plants or at facilities providing collection storage transportation conditioning processing temporal storage and final disposal of radioactive waste)
bull Activity measurement of extended objects in situ without opening the equipment
bull Activity measurement of extended objects after opening (for example assessment of tubes used for oil transportation)
MKG-01D ldquoSADOVNIKrdquoSPECTROMETRY SYSTEM
Physical charachteristicsDetectorbull Detector unit GEM (GMX) with HPGe detector and
multi-positioning cryostat CFG-PMOD4-7 with 7 litre Dewar
bull Dose rate probe BDMG-200
Energy range bull With GEM detector 004 divide 30 MeVbull With GMX detector 0005 divide 15 MeVbull Dose rate probe BDMG-200 ndash 005 divide 30 MeV
Measurement rangebull 110-7 divide 10 Svhbull Relative efficiency of detection (in photopeak) at
13325 MeV (Co-60) 10 divide 150
Electrical characteristicsPower supplybull 220 V 50 Hz
Interfacebull USB
Complete setBasic complete setbull Spectrometric detector unit GEM (GMX) with
HPGe detector and multi-positioning cryostat with 7 litre Dewar
bull Portable digital multichannel analyzer DigiDARTbull Dose rate probe BDMG-200bull Autonomous power supply unit with built-in
batterybull Industrial computer keyboardbull Laser range-finderbull Thermographic printerbull Web-camerabull Device equipped with stepper motor for position-
ing of the spectrometric detectorbull Calibration device with reference sources
(Am-241 Co-60 Ba-133 Eu-152) for energy calibration
bull Removable collimators with end capbull Measurement proceduresbull ldquoClasterrdquo software
bull Measurement of gross alpha activity of alpha-emitting radionuclides
bull Measurement of alpha-emitting radionuclides activity in thin-layer samples meeting alpha-spectrometry requirements
Physical characteristicsDetectorbull Silicon ion-implanted 450 mm2
bull Easy to decontaminate thin windowbull dead layer less than 015 μmbull Background count rate in the range 3 divide 9 MeVbull No more than 09 h-1cm-2 for 450 mm2 detector
Energy rangebull 2 divide 9 MeVbull Lower limit of measurement range (minimum
detectable activity) 01 Bqbull Background count rate no more than 100 counts
in 24 hours
Electrical characteristics Power supplybull 220 V 50 Hz
Interfacebull USB
Complete setBasic complete setbull Detector unit with vacuum measuring chamber
and vacuum control systembull Low noise vacuum pump (type 2FY-05B or
equivalent)bull Check sourcebull ldquoProgressrdquo softwarebull Vacuum tube
MKS-01A ldquoMULTIRAD-ASrdquoALPHA SPECTROMETER
SPC ldquoDozardquoRadiation monitoring equipment
72 73
UCRV-2AIRFLOW MONITOR
bull Monitor of the air flow through filter of centralized multichannel sampling system
bull Radiation monitoring system (RMS) integration for internal exposures determination
bull Volume and flow rate measurements of the air that have passed through a analytical filter
bull Bar-code for filter identificationbull Operation as either standalone unit or as a part of
the RMS
Physical characteristicsMeasurement range of air volume bull 001 divide 9999 m3
Operation temperature range bull minus 20 divide +50 ordmС
Electrical characteristicsPower supply bull 220 V 50 Hz
Interface bull RS-485
PVP-06PORTABLE AIR SAMPLER
Air Sampler PVP-06 is indispensable for monitoring the radiation situation where the concentration of radioactive aerosols in the air does not require a sta-tionary sampling equipment Sampling head PVP-06 provides easy change of filters and cartridges
Purposebull To monitor the concentration of radioactive aero-
sols in the air sites
Controlled aerosolsbull Alpha- and beta-active aerosolsbull Daughter products of decay of radon and thoronbull Iodine isotopes
Physical characteristicsTypes of filtersbull Aerosol AFA-RSP-20bull Iodine AFA SI-20
Flow rate bull 33∙10-4 ndash 233∙10-4 m3s (20 divide 140 l min)
Electrical characteristicsPower supply bull 220 V50 Hzbull The vehicle power supply 108 divide 145 Vbull Internal battery
Minimal working time on internal battery to recharge bull 8 hours
Power consumption (at a flow rate of 100 lmin) bull 40 VA
Environment characteristicsOperating temperature bull minus 10 divide +40 deg C
Maximum humidity bull 90
Pressure bull 860 to 1060 hPA
Noise generated by the pump bull lt 55 dBA at 1 m
Mechanical characteristicsDimensions weight bull 241 times 108 times 160 mm 28 kg
Case material bull Plastic
Complete setbull Air sampler PVP-06bull AC power adapterbull Filters AFA-RSP-20 - 100 pcsbull Packaging for filters - 40 pcsbull Casebull Operation manualbull Calibration certificate
Optional equimpient bull Kit for sampling sorption columns of activated
carbon Ř head of sorption columns with protective
covers Ř activated charcoal SKT-3 - 1 pkg (02 L) Ř charocoal samples SC-13 - 8 pcs
bull Car charger bull Tipod bull Shoulder strapbull Calibration stand bull Filters AFA SI-20 - 100 pcs
Consumablesbull Aerosol filters AFA RSP-20bull Iodine filters AFA SI-20
SPC ldquoDozardquoRadiation monitoring equipment
74 75
Calibration of gamma dose and dose rate meters
Calibration ofbull Ambient equivalent dose H(10) meters (Sv Svh)bull Personal equivalent dose Hp(10) meters (Sv Svh)bull Exposure dose X meters (R Rh)bull Two sources in irradiator bull Select source and collimator opening using
tumbler
UPG-P DESKTOP GAMMA BEAM IRRADIATOR
Physical characteristicsRange of reproduced dose rate bull 05 μSvh divide 10 mSvh (50 μRh divide 100 mRh)
Sources activities bull 6times106 6times108 Bq (02 20 mCi) Cs-137
Overall dimensions bull 1250times400times300 mm
Irradiator weight bull Not more than 37 kg
Calibration bench weight bull Not more than 15 kg
Reference standards IEC 60846 IEC 61526
Physical characteristicsDetectorbull Silicon
Measurement range EEC measurement bull Measurement range of radon EEC
10 divide 10bull106 Bqbullm-3
bull Measurement range of thoron EEC 05 divide 10bull104 Bqbullm-3
bull Air flow through the filter 100plusmn05 lmin
Concentration measurementbull Measurement range of radon-222 concentration
in air 10 divide 20bull106 cpsbull Measurement range of 216Po(ThA)
1bull10-3 divide 1bull102 cpsbull Air sampler flow rate
10plusmn02 lminbull Measurement range of radon-222 concentration
in water samples 6 divide 800 Bqbullkg-1
bull Measurement range of radon-222 flux from soil surface 20 divide 103 mBqsbullm2
bull Measurement range of radon-222 concentration with preliminary sampling of air using air sam-plers 20 divide 107 Bqbullm-3
bull Measurement range of radon-222 concentration in samples of soil air 103 divide 106 Bqbullm-3
Operation temperature range bull 1 divide 35 ordmC
Electrical characteristicsPower supply bull 80 VA
Mechanical characteristicsOverall dimensions weight bull 220times200times165 mm 36 kg
ldquoALPHARAD PLUSrdquoRADON THORON amp THEIR PROGENY MONITORbull Measurement of radon and thoron concentration
and effective equivalent concentration (EEC)bull In the airbull In the indoor air of residential public and industri-
al buildings and structuresbull Measurement of radon in drinking water sourcesbull Measurements of radon flux from the soil surface
at land plots allocated for construction of houses public buildings and industrial facilities
bull Measurements of radon concentration in soil air
Reference standards IEC 61577
SPC ldquoDozardquoRadiation monitoring equipment
76 77
UKPN-2M-D NEUTRON BEAM IRRADIATOR
Reference standards IEC 61005 61322
Calibration of neutron dose and dose rate meters
Calibration ofbull Ambient equivalent dose H(10) meters (Sv Svh)bull Personal equivalent dose Hp(10) meters (Sv Svh)bull Flux density of neutrons (cm-2∙s-1)bull Transfer container for temporary storage of
sources bull Red light signal of source working position
Physical carachteristicsRange of reproduced dose ratebull 20 divide 800 μSvh
Range of reproduced flux densitiesbull 10 divide 400 cm-2∙s-1
Type of a source in use bull Pu-Be
Activity of a source in usebull 24х1011 Bq (with density of 107 s-1)
Overall dimensions weight no morebull 3000x750x2000 mm 300 kg
Required room dimensionsbull not less than 7x3x3 m
Electrical characteristicsPower supply bull 220 V 50 Hz
Calibration of gamma dose and dose rate meters
Calibration ofbull Ambient equivalent dose H(10) meters (Sv Svh)bull Personal equivalent dose Hp(10) meters (Sv Svh)bull Exposure dose X meters (R Rh)bull Four sources in irradiator bull Select source and move to working position
return to storage position using special rodbull Transfer container for temporary storage of
sources bull Red light signal of source working position
UPGD-2M-DGAMMA BEAM IRRADIATOR
Physical characteristicsRange of reproduced dose rate bull 05 μSvh divide 50 mSvh (50 μRh divide 5 Rh)
Maximum activity of source bull 2times1011 Bq (50 Ci) Cs-137
Overall dimensionsbull Irradiator 800times500times500 mmbull Guide rails length 30 mbull Height 16 mbull Weight not more than 700 kgbull Required room dimensions not less than 7x3x3 m
Electrical characteristicsPower supply bull 220 V 50 Hz
UPGD-2M-D
Reference standards IEC 60846 IEC 61526 IEC 61066
SPC ldquoDozardquo
78 79
Contents
MEASURING UNITS
DBG-S11D wide range gamma area monitor 40
UDKS-100 gamma and X-ray area monitor 41
UDMN-100 neutron area monitor 41
ALARM UNITS
BAS-2 ldquoMICROrdquo external visual alarm 42
BZS-2 ldquoMicrordquo external audible alarm 42
Illuminated warning signs 43
ldquoImpulsrdquo external display unit 43
UIM-3D area monitor count rate meter 44
DKG-05D personal gamma dosimeter 46
DVS-02D gamma-neutron personal electronic dosimeter 47
DVGI-8D new pen-type personal ionization chamber dosimeters 48
DKG-02U ldquoARBITERrdquo wide range gamma-dosimeter 49
DKG-07D ldquoDROZDrdquo gamma-dosimeter 50
MKS-15D ldquoSNEGIRrdquo multi ndash purpose radiation survey meter 51
SRPS-05D gamma monitor 52
DOZA-TLD multipurpose TLD system 53
DKS-96 universal radiation survey meter 54
EXTERNAL PROBES ALPHA
Alpha BDZA-96 55
Alpha BDZA-96B 55
Alpha BDZA-96M 55
Alpha BDZA-96S 55
Alpha BDZA-96T 55
EXTERNAL PROBES BETA
Beta BDZB-96 56
Beta BDZB-99 56
Beta BDZB-96B 56
Beta BDZB-96S 56
EXTERNAL PROBES GAMMA
Gamma BDKS-96B 57
Gamma and beta BDKS-96S 57
Gamma BDMG-96 57
EXTERNAL PROBES GAMMA
Gamma-search BDVG-96 58
Gamma-search BDPG-96 58
ContentsRadiation monitoring systemldquoPELIKANrdquo Radiation monitoring system (RMS) 6
BDMG-101 high range gamma area monitor 10
DBG-S11D wide range gamma area monitor 11
BDRG-52 high range gamma area monitor for accident and post-accident conditions 12
UDGP-01 Liquid technological environments monitor 13
UDMN-100 neutron area monitor 14
UDKG-100 Wel Liquid gamma monitor 14
BOP-1M data processing and transmission unit 15
UDA-1AB particulate monitor 16
UDG-1B noble gas monitor 17
UDG-03D noble gas monitor 18
UDI-1B iodine monitor 19
UDGB-01 noble gasesH-3C-14 monitor 20
UDGP-01 steam generator leakage monitor 21
UPPVM air flow parameters monitor 22
ldquoIMPULSrdquo external display unit 23
BI-2 remote display amp alarm unit 24
BASBAS-1s external alarm 25
SKGAV stack monitor 26
RMS software 28
RMS workstation ndash operator console 29
Configurator software 29
RM RACK radiation monitoring rack 30
SRKS-01D criticality accident alarm system 32
ldquoATLANT-Mrdquo environmental radiation monitoring system 34
ldquoBREEZErdquo high-volume air sampler 35
ldquoGAMMA-SENSORrdquo gamma-survey system 36
Radiation monitoring equipmentAREA MONITOR ldquoFREGATrdquo 38
BPI-1D local display unit 39
80
Gamma-search BDPG-96M 58
Gamma BDKG-96 stainless steel casing for geologic applications well logging 59
EXTERNAL PROBES NEUTRON
Neutron BDMN-96 59
Neutron-search BDKN-96 59
RZB-05D Hand-foot-clothing monitor 60
RZBA-04-04M whole body contamination monitor 61
RZA-05D alpha hand-monitor 62
UMF-2000 low level alpha- beta- counter 63
DRK dose area product meter 64
ldquoPROGRESS-BETArdquo scintillation beta spectrometer 65
ldquoPROGRESS-GAMMArdquo scintillation gamma spectrometer 66
ldquoPROGRESS-G(P)rdquo portable scintillation gamma spectrometer 67
ldquoPROGRESS-ARrdquo alpha radiometer 68
ldquoPROGRESSrdquo whole body counter 69
MKG-01D ldquoSADOVNIKrdquo spectrometry system 70
MKS-01A ldquoMULTIRAD-ASrdquo alpha spectrometer 71
UCRV-2 airflow monitor 72
PVP-06 portable air sampler 73
ldquoALPHARAD PLUSrdquo radon thoron amp their progeny monitor 74
UPG-P desktop gamma beam irradiator 75
UPGD-2M-D gamma beam irradiator 76
UKPN-2M-D neutron beam irradiator 77
4
Training Since 1994 ldquoDozardquo has been organizing different types of training Best specialists from national and international research centers come to ldquoDozardquo We provide our trainees with up-to-date methodological and standard norms documents In order to create an independent educational entity in 2007 ldquoDozaldquo founded Educational and Methodological Center ldquoMonitoring and Safetyrdquo This Center is functioning under the License of the Moscow Department of Education
Few references20 NPP use our equipment More than 1000 med-ical institutions are our customers The biggest Ice-breaker in the world is equipped with our RMS Within 2013-2014 we have successfully supplied 450 measuring channels to the bigger Mining and Chemical Complex
Radiation Monitoring
System
Radiation monitoring system SPC ldquoDozardquo
6 7
More than 100 Radiation Monitoring Systems ldquoPelikanrdquo are installed and operating successfully at facilities representing different industries including research reactors nuclear power plants and the icebreaker ldquo50 Years of Victoryrdquo
FeaturesThe RMS ldquoPelikanrdquo constitutes a complex of independent units (intended for measurement of different parameters) that are interconnected into common information network The RMS network
is built using Ethernet IEEE 8023 technology it accommodates measurement devices and workstations as clients The network includes two servers (main and hot standby) or alternatively it can have no server at all The RMS allows performing all commutations necessary for repair or calibration of measurement units in hot mode without interrupting normal network operation
ldquoPELIKANrdquoRADIATION MONITORING SYSTEM (RMS)
Major users of ldquoPelikanrdquo RMS system are Nuclear Power Plants in Russia Ukraine China and India as well as Rosatom Rospotrebnadzor Ministry of Emergency Situations Rosstandard Ministry of Health Ministry of Defense Russian Railways laboratories and other companies and organizations
bull GMP ldquoZvesdochkardquo Severodvinskbull Mining and Chemical Complex Zheleznogorskbull Institute of Physics and Power Engineering
Obninskbull Russian Research Institute of Technical Physics
Sarov
REFERENCE
bull Leningrad NPPbull laquoAtomflotraquobull ldquoZvesdardquo factory Bolrsquoshoy Kamenrsquobull Petersburg Nuclear Physics Institutebull Civil Security Department Moscowbull ldquoRosatomrdquo Corporation MosNPO ldquoRadonrdquobull ldquoRosatomrdquo Corporation ldquoSNIIP-Systematomrdquobull ldquoRosenergoatomrdquo Concern Moscowbull Norilsk Mining and Smelting producerbull Russian Research Institute ldquoVNII Avtomatikardquo
Moscowbull Kudankulam NPP Indiabull Tianwan NPP China
Radiation monitoring system SPC ldquoDozardquo
8 9
SKGAV Stack monitor
UPPVM Air flow parameters monitor
RM Rack
UDG-1B Noble gas monitor
UDGB-01Noble gasesH-3C-14
monitor
UDA-1AB Particulate monitor
UDI-1BIodine monitor
UDGP-01 Steam generator leakage
monitor
RMSworkstation
Ethernet switch
Ethe
rnet
RS
-485
RMS workstationServer
DBG-S11D Wide range gamma area monitor
BDMG-101 High range gamma area monitor
UDMN-100 Neutron area monitor
BDRG-52 High range gamma area monitor
BASBAS-1s External alarm
BOP-1M Data processing and
transmission unit
RADIATION MONITORING SYSTEM
Ethe
rnet
RS
-485
BI-2 Remote display amp alarm unit
ldquoImpulsrdquoExternal Display Unit
UDKG-100 Wel Liquid gamma monitor
Ethernet RS-485 Ethernet RS-485
UDG-03D Noble gas monitor
UDGP-01 Liquidtechnological environment monitor
Radiation monitoring system SPC ldquoDozardquo
10 11
bull Continuous automatic monitoring of the ambient dose equivalent rate
bull Нigh temperature range (up to 120 degC)
BDMG-101 HIGH RANGE GAMMA AREA MONITOR
Physical characteristicsbull detector ndash ionization chambers
Measurement rangebull MIC-1 5∙10-5 divide 200 Svhbull MIC-2 5∙10-4 divide 1000 Svhbull MIC-3 1∙10-5 divide 100 Gyhbull MIC-4 5∙10-3 divide 10000 Gyh
Energy rangebull 005 divide 30 MeV
temperature rangebull ionization chamber module MIC-1
minus 30 divide +120 degCbull electrometric module MIC-2 MIC-3 MIC-4 ME
minus 30 divide +60 degC
Electrical characteristicsbull interfaces RS-485bull cable length between MIC and ME up to 30 m
Mechanical characteristicsbull Protection index IP 65
Overall dimensions weightbull ME Oslash105times293 mm 23 kgbull MIC-1 Oslash85times206 mm 12 kgbull MIC-2 Oslash45times156 mm 03 kgbull MIC-3 Oslash136times226 mm 09 kgbull MIC-4 Oslash35times92 mm 02 kg
BOP-1M
Reference standards Nuclear IEC 60846 IEC 60532
DBG-S11D WIDE RANGE GAMMA AREA MONITOR
Continuous automatic monitoring of the ambient dose equivalent rate
Physical characteristicsbull Detector ndash GM counters
Measurement rangebull DBG-S11D 01 μSvh divide 10 mSvhbull DBG-S11D-01 01 μSvh divide 10 Svhbull DBG-S11D-02 01 μSvh divide 100 Svh
Energy rangebull 005 divide 30 MeV
Temperature range bull minus 40 divide +50 ordmC
Electrical characteristicsbull Interfaces RS-485 USB
Mechanical characteristicsbull Protection index IP 68bull Paint decontaminable
Overall dimensions weightbull DBG-S11D Oslash 68times141 mm 065 kg bull DBG-S11D-01 Oslash 68times179 mm 07 kgbull DBG-S11D-02 Oslash 68times179 mm 07 kg
Versionsbull DBG-S11Dbull DBG-S11D-01bull DBG-S11D-02
BOP-1M
Reference standards Nuclear IEC 60532
Versionsbull stainless steel 100 cm2 ionization chamber
module (MIC-1) and electrometric module (ME)bull stainless steel 20 cm2 ionization chamber module
(MIC-2) and electrometric module (ME)bull duralumin 500 cm2 ionization chamber module
(MIC-3) and electrometric module (ME)bull titanium 2 cm2 ionization chamber module
(MIC-4) and electrometric module (ME)
Radiation monitoring system SPC ldquoDozardquo
12 13Reference standards EMC IEC 61010 IEC 61000-6-2 Seismic IEC 60980
bull Continuous automatic monitoring of the ab-sorbed dose rate
bull Monitoring inside containmentbull Delivery assembled detector and communication
linebull Communication line include inter wall protective
tubebull Hermetic communication line filled dry nitrogen
Physical characteristicsbull detector - stainless steel ionization chamber
Measurement range bull 10-3 divide 105 Gyh
Energy range bull 006 divide 30 MeV
Temperature range bull detector
0 divide 207 ordmC continuous
250 ordmC during 1 hour bull electrometric module 0 divide +60 ordmC
Detector operating pressure bull 07 МPa
Electrical characteristicsbull Interfaces RS-485bull detector-electrometric module cable length up
to 70 m
BDRG-52 HIGH RANGE GAMMA AREA MONITOR FOR ACCIDENT AND POST-ACCIDENT CONDITIONS
Ionization chamber
Mechanical characteristicsProtection index bull detector - IP 65bull electrometric module - IP 23bull Paint stainless steel
Overall dimensions weight bull detecting unit Oslash50х220 mm 3 kgbull inter wall protective tube Oslash 159 length (by order)
1200 ndash 1600 mm 60 kgbull electrometric module 420x420x120 mm 8 kg
Reference standards Nuclear IEC 60951 EMC IEC 61010 IEC 61000-6-2 Seismic IEC 60980
Continuous monitoring of technological environ-ments liquid couples sludges etc bull On line gamma spectrometry
Physical characteristicsbull Detector ndash scintillator CsI NaI
Measurement range bull Gamma-activity 10bull104 divide 20bull108 Bqm3
Energy range bull gamma 005 divide 15 MeV
Temperature range bull minus 10 divide +80 ordmС
UDGP-01 LIQUID TECHNOLOGICAL ENVIRONMENTS MONITOR
Electrical characteristicsbull Interfaces RS-232 RS-485 Ethernetbull programmable relay output (SPDT relay)
Mechanical characteristicsbull Protection index IP 65bull Paint decontaminable
Overall dimensions weight bull Detector unit
CsIOslash 60x360 mm17 kg NaIOslash 35x750 mm26 kg
bull Data processing and transmission unit BOP-1sp 280x220x114mm 43 kg
Alarmbull Sound alarm 80 divide 100 dBA at distance 1 mbull Visual alarm green yellow redbull Connection of the external alarm unit of ldquoBASrdquo
type
Radiation monitoring system SPC ldquoDozardquo
14 15
BOP-1M DATA PROCESSING AND TRANSMISSION UNIT
bull Processing of data incoming from detecting blocks UDMN-100 DBG-S11D UDKG-100 BDMG-101 BDRG-52
bull Data transmission to the network bull Data transmission to the mobile computer bull Storage of thresholds values and parameters of
detecting blocksbull Power supply and diagnostics of detecting blocks bull Generation of the alarm signals of the excess of
preset thresholdsbull Data backup in the non-volatile memory
Physical characteristicsbull Quantity of joined detecting blocks and alarm
units ndash up to 20bull Temperature range minus 40 divide +50 ordmC
Electrical characteristicsbull Power supply 85 divide 260 V 47 divide 440 Hzbull Interfaces RS-232 RS-485 Ethernet bull programmable relay output (SPDT relay)
Mechanical characteristicsbull Protection index IP 65 bull Paint decontaminable
Overall dimensions weightbull 298times220times114 mm 5 kg
Reference standards EMC IEC 61010 IEC 61000-6-2 Seismic IEC 60980
Continuous automatic monitoring of the neutron-radiations ambient dose equivalent ratebull Spherical polyethylene moderator Oslash 239 mm
UDMN-100 NEUTRON AREA MONITOR
Physical characteristicsbull detector ndash scintillator ZnS(Ag) Li-6
Measurement range bull 01 μSvh divide 01 Svh
Energy range bull 0025 eV divide 100 MeV
Temperature range bull minus 45 divide +50 ordmC
Electrical characteristicsbull Interfaces RS-485
Reference standards Nuclear IEC 61005 IEC 61322 EMC IEC 61010 IEC 61000-6-2 Seismic IEC 60980
UDKG-100WEL LIQUID GAMMA MONITOR
Mechanical characteristicsbull Protection index IP 65bull Paint decontaminable
Overall dimensions weight bull 428times258times347 mm 115 kg
Continuous automatic monitoring of the gamma radiation flux Operation in the rocks ore liquid media and sludge
Physical characteristics bull detector ndash NaI (Tl) Oslash 18x30 mm
Measurement range bull 40 divide 8104 s-1cm-2
Energy range bull 01divide 30 MeV
Temperature rangebull minus 40 divide +50 degC
Electrical characteristics bull Interfaces RS-485
Mechanical characteristics bull Protection index
Ř BDKG-100 IP 68 Ř Interface block BS-16 IP 65
bull Paint stainless steel bull Overall dimensions weight
Ř Detector unit BDKG-100 Oslash 38times530 mm 3 kg Ř Interface block BS-16 176times80times64 07 kg
Radiation monitoring system SPC ldquoDozardquo
16 17
UDG-1B NOBLE GAS MONITOR
Continuous automatic monitoring of the beta-emit-ting radioactive gases concentration in the working air and in the air in ventilation ducts and stacksbull Gamma background compensation bull Audible and visual alarm signals of the excess of
preset thresholds bull Periodic calibration by means of standard beta-
source
Physical characteristicsbull Silicon detectors (2 pcs for measurement and for
background compensation)bull Air flow rate 10 divide 100 lminbull Operation temperature range minus 10 divide +50 ordmС
Measurement range bull 104 divide 6109 Bqm3
Energy range bull 008 divide 30 MeV
Electrical characteristicsbull Power supply 85 divide 260 V 47 divide 440 Hzbull Interfaces RS-232 2timesRS-485 Ethernetbull programmable relay output (SPDT relay)bull Analog output 4-20 mA (optional)
Mechanical characteristicsbull Protection index IP 65bull Paint decontaminable
Overall dimensions weight bull Stationary version 395times240times304 mm 295 kgbull Mobile version with pump unit BN-1
395times468times950 mm 543 kg
Alarmbull Sound alarm 80 divide 100 dBA at distance 1 mbull Visual alarm green yellow red
Mobile version with pump unit BN-1
Stationary version
Reference standards Nuclear IEC 60761 IEC 62302 EMC IEC 61010 IEC 61000-6-2 Seismic IEC 60980
bull Connection of the external alarm unit ldquoBASrdquo type
Versionsbull Stationary versionbull Stationary version with pump unit BN-1bull Mobile version with pump unit BN-1
UDA-1AB PARTICULATE MONITOR
Stationary version
Continuous automatic monitoring of the alpha- and beta- radioactive aerosol concentration in the work-ing air and in the air in ventilation ducts and stacksbull Radon toron progenies and gamma background
compensation bull On line alpha spectrometrybull Audible and visual alarm signals of the excess of
preset thresholds bull Control of electromagnetic valves when operating
with the external air sampling linebull Control of pump unit bull Periodic calibration by means of standard beta-
and alpha-sources
Physical characteristicsbull Silicon specrometric detectors (2 pcs for measure-
ment and for background compensation)bull Filter tape types LFAS FSLWbull Tape consumption (when continuous operation)
10 m50 daysbull Air flow rate 10 divide 100 lmin bull Operation temperature range minus 10 divide +50 ordmС
Measurement range bull Alpha 10-2 divide 2105 Bqm3 bull Beta 10-1 divide 106 Bqm3
Energy range bull Alpha 30 divide 90 MeV bull Beta 005 divide 30 MeV
Electrical characteristicsbull Power supply 85 divide 260 V 47 divide 440 Hzbull Interfaces RS-232 2timesRS-485 Ethernet bull Programmable relay output (SPDT relay)bull Analog output 4-20 mA (optional)
Mechanical characteristicsbull Protection index IP 65bull Paint decontaminable
Overall dimensions weight bull Stationary version 389times260times304 mm 156 kg bull Mobile version with pump unit BN-1
389times468times950 mm 384 kg
Alarmbull Sound alarm 80 divide 100 dBA at distance 1 mbull Visual alarm green yellow redbull Connection of the external alarm unit ldquoBASrdquo type
Versionsbull Stationary versionbull Stationary version with pump unit BN-1bull Mobile version with pump unit BN-1
Reference standards Nuclear IEC 60761 IEC 61172 EMC IEC 61010 IEC 61000-6-2 Seismic IEC 60980
Mobile version with pump unit BN-1
Radiation monitoring system SPC ldquoDozardquo
18 19
Physical characteristicsbull Scintillation detectors CsI(Tl) (2 pcs for measure-
ment and for background compensation)bull Cartridge activated charcoal
Measurement range bull 37 divide 37106 Bqm3
Energy range bull 006 divide 30 MeVbull Air flow rate 20 divide 40 lminbull Operation temperature range minus 10 divide +50 ordmС
Electrical characteristicsbull Power supply 85 divide 260 V 47 divide 440 Hzbull Interfaces RS-232 2timesRS-485 Ethernetbull Programmable relay output (SPDT relay)bull Analog output 4-20 mA (optional)
Mechanical characteristicsbull Protection index IP 65bull Paint decontaminable
Overall dimensions weight bull Stationary version 448times323times479 mm 35 kgbull Mobile version with pump unit BN-1
448times468times950 mm 578 kg
Reference standards Nuclear IEC 60761 IEC 61171 EMC IEC 61010 IEC 61000-6-2 Seismic IEC 60980
Alarmbull Sound alarm 80 divide 100 dBA at distance 1 mbull Visual alarm green yellow redbull Connection of the external alarm unit of ldquoBASrdquo
type
Versionsbull Stationary versionbull Stationary version with pump unit BN-1bull Mobile version with pump unit BN-1
Сontinuous automatic monitoring radioiodine concentration in the air at working places and in ventilation ducts and stacksbull Measurement of volumetric activity of radionu-
clides I-131 I-132 I-133 I-135 in the airbull On line gamma spectrometrybull Gamma background compensation bull Performance self-test by means of Am-241 check
source implanted into the detectorbull Audible and visual alarm signals of the excess of
preset thresholdsbull Periodic calibration by means of standard source
UDI-1B IODINE MONITOR
Physical characteristicsbull Silicon detector 2 pcs (for measurement and for
background rejection)bull Air flow rate 10 divide 100 lminbull Operation temperature range minus 10 divide +50 ordmС
Measurement range bull 104 divide 11010 Bqm3
Energy rangebull 006 divide 30 MeV
Electrical characteristicsbull Power supply 120 Vbull Interface RS-485
Mechanical characteristicsbull Protection index IP 65bull Paint decontaminable
Overall dimensions weight bull 474х246х243 mm 295 kg
UDG-03D NOBLE GAS MONITOR
Measurement of volumetric activity of beta-emitting radioactive gases (argon krypton xenon) adapted to the measurement of the rapidly changing volume activity in various technological processesbull Gamma background compensationbull Periodic calibration by means of standard beta-
source
Reference standards Nuclear IEC 60761 IEC 62302 EMC IEC 61010 IEC 61000-6-2 Seismic IEC 60980
Radiation monitoring system SPC ldquoDozardquo
20 21
Continuous automatic monitoring of steam genera-tor primary to secondary leakagebull On line gamma spectrometrybull N-16 monitoringbull Performance self-test by means of Am-241 check
source implanted into the detectorbull Audible and visual alarm signals of the excess of
preset thresholds
Physical characteristics
UDGP-01 STEAM GENERATOR LEAKAGE MONITOR
bull detector ndash scintillator CsI Oslash 40х100 mm
Measurement range bull High energy gamma-activity (N-16)
15bull103 divide 20bull108 Bqm3
bull General gamma-activity 10bull104 divide 20bull108 Bqm3
Energy range bull General gamma 005 divide 15 MeV bull in integral spectral band of energy
5000 divide 7200 keV bull temperature range minus 10 divide +80 ordmС
BOP-1SP
Electrical characteristicsbull Power supply 85 divide 260 V 47 divide 440 Hzbull Interfaces RS-232 RS-485 Ethernetbull programmable relay output (SPDT relay)
Mechanical characteristicsbull Protection index IP 65bull Paint decontaminable
Overall dimensions weight bull Detector unit Oslash 60x360 mm17 kgbull Data processing and transmission unit BOP-1sp
280x220x114mm 43 kgbull Collimator Oslash 350x455 mm 150 kg
Alarmbull Sound alarm 80 divide 100 dBA at distance 1 mbull Visual alarm green yellow redbull Connection of the external alarm unit of ldquoBASrdquo
type
Reference standards Nuclear IEC 61453 EMC IEC 61010 IEC 61000-6-2 Seismic IEC 60980Reference standards Nuclear IEC 60761 IEC 60710 IEC 60951-2 EMC IEC 61010 IEC 61000-6-2 Seismic IEC 60980
Ionization chambe 10 liters
UDGB-01T1
Physical characteristicsbull Detectors - stainless steel ionization chambersbull Air flow rate 10 divide 100 lminbull Operation temperature range minus 10 divide +50 ordmС
Volumes of ionization chambers bull UDGB-01T UDGB - 01T1 100 litersbull UDGB-01T2 01 liter
Measurement range (Kr-85) bull UDGB-01T UDGB-01T1 10104 divide 50109 Bqm3
bull UDGB-01T2 109 divide 501014 Bqm3
Measurement range (H-3) bull UDGB-01T UDGB-01T1 50104 divide 50109 Bqm3
bull UDGB-01T2 50109 divide 501014 Bqm3
Electrical characteristicsbull Power supply 85 divide 260 V 47 divide 440 Hzbull Interfaces RS-232 2timesRS-485 Ethernetbull Programmable relay output (SPDT relay)bull Analog output 4-20 mA (optional)
Mechanical characteristicsbull Protection index IP 23bull Paint decontaminable
Continuous automatic monitoring of the beta-emitting radioactive gases including tritium and carbon-14 concentration in the air at working places and in ventilation ducts and stacksbull Audible and visual alarm signals of the excess of
preset thresholds bull Monitoring of the noble gase activity in gaseous
effluents and ventilation air for accident and post-accident conditions
Overall dimensions weight bull UDGB-01T 381times343times716 mm 30 kgbull UDGB-01T1 260times320times175 mm 125 kgbull Ionization chamber 100 liters Oslash 250times600 mm
6 kgbull UDGB - 01T2 381times343times716 mm 27 kg
Alarmbull Sound alarm 80 divide 100 dBA at distance 1 mbull Visual alarm green yellow redbull Connection of the external alarm unit ldquoBASrdquo type
Versionsbull UDGB-01T - with built-in ionization chamber
100 litersbull UDGB-01T2 - with built-in ionization chamber
01 literbull UDGB-01T1 - with remote ionization chamber
100 liters
UDGB-01NOBLE GASESH-3C-14 MONITOR
Radiation monitoring system SPC ldquoDozardquo
22 23
Physical characteristicsLength of communication cablebull up to 1200 m
Character height bull ldquoImpuls-910-Rrdquo 100 mmbull ldquoImpuls-915-D4Srdquo 150 mmbull ldquoImpuls-927-D4Srdquo 270 mm
Operating temperature rangebull ldquoImpuls-910-Rrdquo 0 divide +50 ordmCbull ldquoImpuls-915-D4Srdquo ldquo-927-D4Srdquo minus 40 divide +50 ordmC
Electrical characteristicsbull Power supply 220 V 50 Hz
Mechanical characteristicsProtection index bull ldquoImpuls-910-R IP 44bull ldquoImpuls -915-D4Srdquo ldquo-927-D4Srdquo IP 65
Overall dimensions weight bull ldquoImpuls-910-Rrdquo 400times160times60 mm 3 kgbull ldquoImpuls -915-D4Srdquo 815times250times80 mm 5 kgbull ldquoImpuls -927-D4Srdquo 1250times330times80 mm 5 kg
ldquoIMPULSrdquoEXTERNAL DISPLAY UNIT
Display of data received from monitors of RMS
External display unit ldquoImpuls-910-Rrdquo
Reference standards EMC IEC 61010 IEC 61000-6-2 Seismic IEC 60980
Continuous monitoring of the flow rate temperature and humidity of the gas flowbull Definition of air volume flow rate in stacks taking
into account temperature and humidity of the air
UPPVM AIR FLOW PARAMETERS MONITOR
Physical characteristicsMeasurement range bull air flow velocity 1 divide 20 msbull air temperature 0 divide +80 ordmСbull air humidity 10 divide 95
Electrical characteristicsbull Power supply 220 V 50 Hz bull Interfaces RS-232 Ethernet
Mechanical characteristicsProtection index bull BSPP-1st BSPP-1tv BOP-1s IP 65bull PP-st IPTV IP 54bull Paint decontaminable
Overall dimensions weight bull air velocity probe PP-st 60times38times136 mm 015 kgbull Interface block BSPP-1st 125times155times73 mm 07 kgbull air temperature and relative humidity probe
IPTV-056-A 333times100times60 mm 07 kgbull Interface block BSPP-1tv 125times155times73 mm 07 kgbull Data processing and transmission unit BOP-1s
280x233x111 mm 8 kg
Reference standards Nuclear ISO 2889 EMC IEC 61010 IEC 61000-6-2 Seismic IEC 60980
BOP-1S
Radiation monitoring system SPC ldquoDozardquo
24 25
BASBAS-1S EXTERNAL ALARM
Generation of audible and visual signals of the excess of preset thresholds RMS monitorsbull Audible alarm 80 divide 100 dBA at distance 1 mbull Visual alarm green yellow red
Distance from RMS monitorbull BAS up to 20 mbull BAS-1s up to 1200 m
Power supply bull 220 V 50 Hz
Overall dimensions weight bull BAS 145times108times460 mm 18 kg bull BAS-1s 166times109times466 mm 18 kg
Reference standards EMC IEC 61010 IEC 61000-6-2 Seismic IEC 60980
Physical characteristicsLength of communication cablebull up to 1200 m
Displayed page size bull 4 lines of 20 characters
Volume of loaded information bull 10 pages
Change of pagesbull programmed or by pressing a button
Operating temperature rangebull minus 40 divide +50 ordmC
Electrical characteristicsbull Power supply 9 divide 18 VDCbull Interfaces RS-485
Mechanical characteristicsbull Protection index IP 65bull Overall dimensions weight 222times164times73 mm
40 kg
BI-2 REMOTE DISPLAY amp ALARM UNIT
bull Display of data received from monitors of RMSbull Audible and visual alarms on exceeding preset
thresholds of the RMS equipment bull Individual threshold setting for each measure-
ment channelbull Audible alarm 80 divide 100 dB at a distance of 1 m bull Visual alarm red yellow green
Reference standards EMC IEC 61010 IEC 61000-6-2 Seismic IEC 60980
Radiation monitoring system SPC ldquoDozardquo
2726
Electrical characteristicsbull Power supply 220 V 50 Hz bull Interfaces RS-232 RS-485 Ethernetbull programmable relay output (SPDT relay)
Alarmbull Sound alarm 80 divide 100 dBA at distance 1 mbull Visual alarm green yellow redbull Connection of the external alarm unit ldquoBASrdquo type
Related monitors and equipmentsbull UDA-1AB particulate monitorbull UDG-1B noble gas monitorbull UDI-1B iodine monitorbull UPPVM air flow parameters monitorbull Sampling and sample separation rack
Air flow parameters monitor rack
Reference standards Nuclear IEC 60761 IEC 61171 IEC 61172 IEC 62302 ISO 2889 EMC IEC 61010 IEC 61000-6-2 Seismic IEC 60980
Sampling and sample separation rack
Continuous monitoring of radioactivity in gaseous effluentsbull Automatic monitoring of the alpha- and beta-
radioactive aerosol noble gas and radioiodine concentrations in the air in ventilation ducts and stacks
bull Monitoring of the flow rate temperature and humidity of the gas flow
bull Separation of gaseous effluent into targeted fractions by means of a two-stage filter
bull Reversion of gas after analysis to the ventilation system
Physical characteristics
Particulate (UDA-1AB)bull Silicon specrometric detectors (2 pcs for measure-
ment and for gamma-background compensation) bull Filter tape types LFAS FSLWbull Tape consumption (when continuous operation)
10 m50 days
Measurement range bull Alpha 10-2 divide 2105 Bqm3 bull Beta 10-1 divide 106 Bqm3
Energy range bull Alpha 30 divide 90 MeV bull Beta 005 divide 30 MeV
Noble gas (UDG-1B)bull silicon detectors (2 pcs for measurement and for
gamma-background compensation)
Measurement range bull 104 divide 6109 Bqm3
Energy range bull 008 divide 30 MeV
Iodine (UDI-1B)bull scintillation detectors CsI(Tl) (2 pcs for measure-
ment and for background compensation)
SKGAV STACK MONITOR
Particulate noble gas and iodine monitors rack
Measurement range bull 37 divide 37105 Bqm3
Energy range bull 015 divide 30 MeV
Air flow parameters (UPPVM)Measurement range bull air flow velocity 1 divide 20 msbull air temperature 0 divide +80 ordmСbull air humidity 10 divide 95
Radiation monitoring system SPC ldquoDozardquo
28 29
CONFIGURATOR SOFTWAREMaintenance and set-up softwarebull Set-up and verify RMS monitorsbull Control testing adjustment and repair of RMS
monitorsbull Monitors measurement results archive receive
and View bull Communication through RS-232
RMS WORKSTATION ndash OPERATOR CONSOLEOrganization of interaction of the RMS Server and Monitors
Single monitor console includes vandal-proof key-board amp UPS
Reference standard IEC 61559-1 IEC 61559-2
RMS SOFTWAREData acquisition storing and visual representation RMS monitors measurement resultsbull Ethernet IEEE 8023 networkbull Clientserver architecturebull TCPIP protocolbull Oracle based Data Basebull Supremal by means InSat MasterSCADA
Radiation monitoring system SPC ldquoDozardquo
30 31
Delivery setComposition and modification depend on the tasks to be solved using the RM Rack
The rack which is an integral part of RM Rack accommodatesbull Monitors UDA-1AB UDG-1B UDG-03D UDI-1B
UDGB-01Tbull DBG-S11D Wide range gamma area monitor
BDMG-101 High range gamma area monitor UDMN-100 Neutron area monitor BDRG-52R High range gamma area monitor
bull BI-2 Remote display amp alarm unitbull Pump unit BN-01bull Data processing and transmission unit BOP-1Mbull External alarm BAS or BAS-1sbull Equipment of sampling line (flow meters ball
valves filter holder piping solenoid valve)bull Switchboard (intended for switching of all equip-
ment and transfer of data to the upper level via the unified communication channel)
RM RACK RADIATION MONITORING RACK
The radiation monitoring rack (RM Rack) is designed for continuous monitoring of radiation parameters in premises and technological systems at nuclear facil-ities RM Rack can be used as a structural element of the lower-level of RMS at nuclear power plants and other nuclear facilities that involved in obtaining processing use and storage of radioactive materials
FeaturesContinuous automatic monitoring of the alpha- and beta- radioactive aerosol beta-emitting radioactive gases and radioiodine concentrations in the working air and in the air in stacks and others radiation parameters in the facilities
The stand providesbull Primary processing storage and transmission of
measured and related data into the information channel based on the Ethernet IEEE 8023 inter-face (TCPIP protocol)
bull Transfer of required data to the location where the equipment is installed via technological channels based on RS-232 interface
bull Generation of audible and visual warning alarm signals when the preset thresholds are exceeded
bull Display of received data on the LCD
Radiation monitoring system SPC ldquoDozardquo
32 33Reference standards IEC 60860 ANSIANS-83 ISO 7753
Purposebull Detection and recording of criticality accident
(CA) by measuring the absorbed dose rate of gamma-neutron radiation in the premises of monitored object its comparison with a threshold value and generation of audible and visual signals
bull Automatic collection processing storage and display of measurement data and related infor-mation as visual and graphical representation for operators of nuclear safety service
Functions of the systembull Detection and recording of CA events by con-
tinuous measurement of absorbed dose rate of gamma radiation comparison of measured values with preset thresholds generation of signals to activate the alarm
bull Activation of audible visual alarmbull In the event of CA turning on warning signals
ldquoDO NOT ENTERrdquo at illuminated information pan-els placed at the entrances to the controlled area
Featuresbull Data can be transferred to external data commu-
nication channel using RS-485 interface (DiBus data exchange protocol)
bull Automatic self-testing of detection units BR-04D with display of information about the type of fault
bull Possibility for connecting additional a detection and alarm units
bull Ability to function in general regardless of the functioning of components within the agreed scope of nuclear safety tasks
bull Radiation hardness up to 100 Gy
SRKS-01DCRITICALITY ACCIDENT ALARM SYSTEM
Features of softwarebull Collection of information via RS-485 network
displaying it on the PC monitor transmission to remote users archiving and storage
bull Status monitoring and display of values measured by BR-04D and DBG-S11D in locations as per layout of premises
bull Access to archived data with possibility to gener-ate reports for periods determined by operator
bull Maintenance and archiving of a log of dosimetric measurements data and events along with their time stamps
bull Possibility to transfer data to external users via Ethernet network for integrating of CA into higher level systems
Basic complete setLower level bull Control unit with power supplybull BR-04D detection unitsbull BZS-01D audible alarm unitsbull BSS-01D visual alarm unitsbull SIT-01D illuminated warning signsbull PBZ panels for muting audible alarmbull Network communication module
Additional lower layer devicesbull DBG-S11D wide range gamma area monitor
Upper layer bull CDP central display panelbull Service workstation
RS-485
RS-485
RS-4
85
Audible alarm units BZS-01D
Illuminated warning signs SIT-01D
Detection units BR-04D
Network communication
moduleDBG-S11D wide range gamma area monitor
Panels for muting audible alarm
Control unit with power supply
Visual alarm units BSS-01D
RS-485
RS-485
RS-4
85
Audible alarm units BZS-01D
Illuminated warning signs SIT-01D
Detection units BR-04D
Network communication
moduleDBG-S11D wide range gamma area monitor
Panels for muting audible alarm
Control unit with pow-er supply
Visual alarm units BSS-01D
RS-485
RS-4
85
Audible alarm units BZS-01D
Illuminated warning signs SIT-01D
Detection units BR-04D
Network communication
moduleDBG-S11D wide range gamma area monitor
Panels for muting audible alarm
Control unit with power supply
Visual alarm units BSS-01D
RS-485
RS-485
RS-4
85
Audible alarm units BZS-01D
Illuminated warning signs SIT-01D
Detection units BR-04D
Network communication
moduleDBG-S11D wide range gamma area monitor
Panels for muting audible alarm
Control unit with power supply
Visual alarm units BSS-01D
Ethernet
Central display panel Service workstation
RS-485
RS-485
RS-4
85
BZS-01D audible alarm units
SIT-01D illuminated warning signs
BR-04D detection units
Network communication
moduleDBG-S11D wide range gamma area monitor
PBZ panels for muting audible alarm
Control unit with power supply
BSS-01D visual alarm units
Radiation monitoring system SPC ldquoDozardquo
34 35
ldquoBREEZErdquoHIGH-VOLUME AIR SAMPLER
Physical characteristicsbull Measurement range of air flow rate
250 divide 1200 m3hbull Continuous operation time not less than 24 h
Filter materialsbull High-purity glass fiberbull Pure quartz or cellulosebull Filter fabric FPP-15-15
Electrical characteristicsPower supply bull 220380 V 50 Hz
Interfaces bull RS-485bull Ethernetbull GSMGPRS (option)
Environmental characteristicsTemperature range bull minus 40 divide + 40 ordmC
Relative humidity limit at 35 ordmC bull 95
Atmospheric pressure range bull 840 divide 1067 kPa
Versionsbull Standalone unit bull Part of Environmental Radiation Monitoring
System (ERMS)
Type of detection unitsbull Beta block BDZB-100Lbull DBG-S11D wide range gamma area monitorbull Scintillation spectrometric block
The motor of Air Sampler is controlled by an electronic flow sensor that detects changes in the operators pre-set flow rate caused by changes in temperature barometric pressure and pressure drop due to dust loading on filter media It compensates for these changes by adjusting the motor speed to maintain the pre-set flow ratebull Measurement of parameters of ionizing radiation bull Standalone mode of operation or as the part
of Environmental Radiation Monitoring System (ERMS)
Purposebull Environmental Radiation Monitoring System
(ERMS) in the control and buffer areas of the radia-tion and nuclear facilities
Referencesbull Since the year 2000 the system is successfully
operating the ERMSs at 8 Russian nuclear power plants (about 180 monitoring stations)
bull Since the year 2005 the ERMS is operating in the Moscow (about 40 monitoring stations)
bull Since the year 2005 the regional ERMS is under operation in several Russian Federation regions
Basic complete setMonitoring stations bull Data processing and transmission unit BOP-1TA bull Gamma area monitor DBG-S11D
Central data processing station (CDPS)bull Data processing and transmission unit BOP-1TAbull Server
By requestbull Emergency Response and Crisis Management
Centers for enterprisesbull Regional Emergency Response and Crisis Manage-
ment Centersbull rdquoBreezerdquo High-Volume Air Samplerbull Mobile lab with gamma-survey system rdquoGammandash
sensorrdquo
ldquoATLANT-MrdquoENVIRONMENTAL RADIATION MONITORING SYSTEM
Monitoring system for the continuous radiation monitoring of territories and facilities with the data transmission GSMGPRS network
Data transmission bull GSMGPRS
Power supply bull 220 V 50 Hz
Continuous autonomous operation (at 20 ordmC)bull From built-in battery not less than 5 hoursbull From external battery not less than 24 hours
Operation temperature bull Minus 40 divide +50 ordmC
Operation humidity bull Up to 98
Protection bull IP65
Reference standards Nuclear IEC 61017-11991 IEC 61017-21994
36
Radiation Monitoring Equipment
bull Localization of radioactive contaminationsbull Database with dose rate contaminations
spectra measurement date amp time coordi-nates
bull Work as part of mobile laboratory or as part of Environmental Radiation Monitoring System with real-time data transfer
Physical characteristicsDetector bull Scintillation NaI (Tl) GM counters
Measurement rangebull 01 ndash 107 μSvh
Energy range bull 005 ndash 3 MeV
Operation temperature range bull minus 10 divide +50 ordmС
Electrical characteristics bull Power supply 220 V 50 Hz
ldquoGAMMAndashSENSORrdquoGAMMA-SURVEY SYSTEM
SPC ldquoDozardquoRadiation monitoring equipment
38 39
AREA MONITOR ldquoFREGATrdquoArea Monitor ldquoFregatrdquo is designed for building rela-tively simple and inexpensive radiation monitoring systems at such facilities as radionuclide sources storage areas isotope products warehouses nuclear medicine departments PET centers calibration laboratories where sources of ionizing radiation are used etc
Small scale automated radiation monitoring systems built with ldquoFregatrdquo components featuring audible and visual alarms are matched suitable to meet the regulatory radiation safety requirements
Area monitor ldquoFregatrdquo requires virtually no adjust-ment it is simple and convenient for installation and operation
BPI-1D LOCAL DISPLAY UNIT
Display of monitored parameters values received from external measuring devices
Purposebull Processing and display of values of monitored
parameters on information panel bull Comparison of values of monitored parameters
with thresholdsbull Transfer of monitored parametersrsquo values to
networkbull Generation of alarm in case of exceeding of preset
thresholds including external alarm devices
FeaturesTesting the unit and connected devicesbull Visually on the panelbull Using adjustment software when connected to
PC via USB
Automatic self-testing
The panel displays the following informationbull Diagnostic information about the status of con-
nected devicesbull Current date and timebull Values of measured parametersbull Position of measured values with respect to the
thresholds in the form of scales with green yellow and red zones
bull Time history (trend) for each measured value
Physical characteristicsTemperature range bull minus 10 divide + 50 ordmC
Maximum number of connected devicesbull measuring devices 15bull external audible and visual alarm 15
Display diagonal bull 152 cm (6)
Electrical characteristicsbull Interfaces RS-485bull Power supply 220 V 50 Hz 12 divide 24 V
Mechanical characteristicsbull Protection index IP54bull Paint decontaminable
Overall dimensions weightbull 296x248x118 mm 5 kg
DBG-S11D wide range gamma area monitor
UDMN-100 neutron area monitor
Ethernet RS-485
UDKS-100 gamma and X-ray area monitor
BPI-1D Local display unit
BAS-2 ldquoMicrordquo external visual alarm
BZS-2 ldquoMicrordquo external audible alarm
ldquoImpulsrdquo external display unit
Service workstation
Illuminated warning signs
SPC ldquoDozardquoRadiation monitoring equipment
4140
Continuous automatic monitoring of the gamma- X-ray ambient dose equivalent rate
Physical characteristicsbull Detector tissue-equivalent plastic scintillator
Oslash 45times20 mm
Measurement range bull Dose rate measurement range 01 μSvh divide 1 Svh bull Energy range 0015 divide 10 MeV
Mechanical characteristicsbull Protection index IP65bull Paint decontaminable
Overall dimensions weightbull Oslash72times265 mm 15 kg
UDKS-100 GAMMA AND X-RAY AREA MONITOR
UDMN-100 NEUTRON AREA MONITOR
Physical characteristicsbull detector ndash scintillator ZnS(Ag) Li-6
Measurement range bull 01 μSvh divide 01 Svh
Energy range bull 0025 eV divide 100 MeV
Temperature range bull minus 45 divide +50 ordmC
Electrical characteristicsbull Interfaces RS-485
Mechanical characteristicsbull Protection index IP 65bull Paint decontaminable
Overall dimensions weight bull 428times258times347 mm 115 kg
Continuous automatic monitoring of the neutron-radiations ambient dose equivalent ratebull Spherical polyethylene moderator Oslash 239 mm
MEASURING UNITS
DBG-S11D WIDE RANGE GAMMA AREA MONITOR
Continuous automatic monitoring of the gamma- ambient dose equivalent rate
Physical characteristicsbull Detector ndash GM counters
Measurement rangebull DBG-S11D 01 μSvh divide 10 mSvhbull DBG-S11D-01 01 μSvh divide 10 Svhbull DBG-S11D-02 01 μSvh divide 100 Svh
Energy rangebull 005 divide 30 MeV
Temperature range bull minus 40 divide +50 ordmC
Electrical characteristicsbull Interfaces RS-485 USB
Mechanical characteristicsbull Protection index IP 68bull Paint decontaminable
Overall dimensions weightbull DBG-S11D Oslash 68times141 mm 065 kg bull DBG-S11D-01 Oslash 68times179 mm 07 kgbull DBG-S11D-02 Oslash 68times179 mm 07 kg
Versionsbull DBG-S11Dbull DBG-S11D-01bull DBG-S11D-02
Reference standards Nuclear IEC 60846 IEC 60532 EMC IEC 61010 IEC 61000-6-2 Seismic IEC 60980
SPC ldquoDozardquoRadiation monitoring equipment
4342
ALARM UNITS
Generation visual signals of the excess of preset thresholds
Physical characteristicsLength of communication cablebull up to 1200 mbull Alarm Visual alarm green yellow red
Electrical characteristicsbull Power supply +12 V
Mechanical characteristicsbull Protection index IP 23
Overall dimensions weight 160times84times41 mm 02 kg
BAS-2 ldquoMICROrdquo EXTERNAL VISUAL ALARM
Generation audible signals of the excess of preset thresholds
Physical characteristicsLength of communication cablebull up to 1200 mbull Audible alarm 80 divide 100 dB at a distance of 1 m
Electrical characteristicsbull Power supply +12 V
Mechanical characteristicsbull Protection index IP 23
Overall dimensions weight 160times84times41 mm 02 kg
BZS-2 ldquoMICROrdquo EXTERNAL AUDIBLE ALARM
Physical characteristicsLength of communication cablebull up to 1200 m
Electrical characteristicsbull Power supply 220 V 50 Hz
Mechanical characteristicsbull Protection index IP 23
Overall dimensions weight bull 330times110times20 mm 05 kg
Physical characteristicsLength of communication cablebull up to 1200 m
Character height bull ldquoImpuls-910-Rrdquo 100 mmbull ldquoImpuls-915-D4Srdquo 150 mmbull ldquoImpuls-927-D4Srdquo 270 mm
Operating temperature rangebull ldquoImpuls-910-Rrdquo 0 divide +50 degCbull ldquoImpuls-915-D4Srdquo ldquo-727-D4Srdquo minus 40 divide +50 degC
Electrical characteristicsbull Power supply 220 V 50 Hz
Mechanical characteristicsProtection index bull ldquoImpuls-910-R IP 44bull ldquoImpuls-915-D4Srdquo ldquo-727-D4Srdquo IP 65
Overall dimensions weight bull ldquoImpuls-910-Rrdquo 400times160times60 mm 3 kgbull ldquoImpuls-915-D4Srdquo 815times250times80 mm 5 kgbull ldquoImpuls-927-D4Srdquo 1250times330times80 mm 5 kg
ILLUMINATED WARNING SIGNS
ldquoIMPULSrdquo EXTERNAL DISPLAY UNIT
SPC ldquoDozardquoRadiation monitoring equipment
4544
Individual threshold setting for each measurement channel
Continuous area and process monitoring
Collect amp display data from two measurement chan-nels (units with RS-485 or analog pulses)
Audible and visual alarms on exceeding preset thresholds or status of connected devices
Individual threshold setting for each measurement channel
Switching on the external alarm or executive devices when any threshold is exceeded
The wide panel displays the following information bull Values of measured parameters as min-1∙cm-2
s-1∙cm-2 μSvhbull Diagnostic information about the status of con-
nected devicesbull Current date and timebull Position of measured values with respect to the
thresholds in the form of scales with green yellow and red zones
bull Time history (trend) for each measured value
Physical characteristics Measurement range bull Count rate up to 107 CPM (170 kHz)
Operating temperature range bull minus 20 divide +50 ordmC
Electrical characteristics bull Power supply 220 V bull Interfaces USB
Mechanical characteristics bull Protection index IP 65 bull Overall dimensions weight 222times164times73 mm
40 kg
UIM-3D AREA MONITOR COUNT RATE METER
Measurement of alpha radiation flux density
Detector unit BDZA-100 (70 cm2) Measurement range 01 divide 104 min-1∙cm-2
Detector unit BDZA-100B (300 cm2) Measurement range 01 divide 2103 min-1∙cm-2
Measurement of beta radiation flux density
Detector unit BDZB-100 (28 cm2) Measurement range 10 divide 105 min-1∙cm-2
Detector unit BDZB-100L (30 cm2) Measurement range 10 divide 104 min-1∙cm-2
Detector unit BDZB-11D (84 cm2) Measurement range 5 divide 15∙104 min-1∙m-2
OPTIONAL PROBESMeasurement of gamma radiation flux density
Detector units BDEG-03 Measurement range 4 divide 2000 s-1∙cm-2
Detector unit UDKG-100 for operation in the rocks ore liquid media and sludge Measurement range 40 divide 8000 s-1∙cm-2
Measurement of the ambient dose equivalent rate
Detector unit DBG-S11D Measurement range 01 μSvh divide 100 Svh
Measurement of neutron radiation ambient dose equivalent rate
Detector unit BDMN-100 Measurement range 01 μSvh divide 01 Svh
SPC ldquoDozardquoRadiation monitoring equipment
46 47Reference standards Nuclear IEC 61526
Measurement of gamma-radiation personal dose equivalent Hp(10)bull Stand-alone dosimeter or composed of dosimetric
system onebull Audible and visual alarmbull Large memory dose accumulation historiesbull Exclusion of unauthorized intervention in dosim-
etry operation
DKG-05D PERSONAL GAMMA DOSIMETER
Physical characteristicsDetectors bull Silicon
Measurement range bull Dose rate 1 μSvh divide 10 Svhbull Dose 01 μSv divide 15 Sv
Energy range bull 005 divide 30 MeV
Electrical characteristicsbull Power supply rechargeable NiMH battery 1
alcaline battery (type AAA)
Operation timebull Till recharging not less 400 hoursbull With one set batteries not less 1000 hours
Mechanical characteristicsOverall dimensions weight bull 47times26times87 mm (with clip) 70 g
Environmental characteristicsbull IP65bull Temperature range minus 20 divide +45 ordmCbull Humidity up to 98 at 35 ordmCbull Shock vibration and drop resistant
Alarmbull Excess of alarm thresholdsbull Warnings of self-test failure and battery discharge bull Audible alarm 80 dB at 40 cmbull Visual alarm blinking LED
Relative equipmentbull One dosimeter charger ZU-1Mbull Chargestorage cassetes KZU-28KZU-56bull ldquoSmart chargingrdquo feature extends battery life timebull DKG-05D reader US-05bull DKG-05D system reader DVS-01D
Reader-PC interfacebull US-05 USB bull DVS-01D Ethernet
KZU-28
Physical characteristicsDetectors bull Silicon Li-6
Gamma measurement range bull Dose rate 1 μSvh divide 10 Svhbull Dose 01 μSv divide 15 Sv
Gamma energy range bull 005 divide 60 MeV
Neutron measurement range bull Dose rate 1 μSvh divide 2 Svhbull Dose 20 μSv divide 15 Sv
Neutron energy range bull 0025 eV divide 20 MeV
Electrical characteristicsPower supply bull Rechargeable NiMH batterybull Operatiion time till recharging not less 200 hours
Mechanical characteristicsOverall dimensions weight bull 47times26times87 mm (with clip) 70 g
Environmental characteristicsbull IP65bull Temperature range minus 20 divide +40 ordmCbull Humidity up to 75 at 30 ordmCbull Shock vibration and drop resistant
Alarmbull Excess of alarm thresholds bull Warnings of self-test failure and battery discharge bull Audible alarm 80 dB at 40 cmbull Visual alarm blinking LED
Relative equipmentbull One dosimeter charger ZU-1Mbull Chargestorage cassetes KZU-28 KZU-56bull ldquoSmart chargingrdquo feature extends battery life timebull DVS-02D reader UZS-01Sbull DVS-02D system reader DVS-01D
Reader-PC interfacebull UZS-01S USB bull DVS-01D Ethernet
UZS-01DReference standards Nuclear IEC 61526
DVS-02D GAMMA-NEUTRON PERSONAL ELECTRONIC DOSIMETER
Measurement of gamma- and neutron radiations personal dose equivalent Hp(10)bull Stand-alone dosimeter or composed of dosimetric
system onebull Audible and visual alarmbull Large memory dose accumulation historiesbull Exclusion of unauthorized intervention in dosim-
etry operationbull Both albedo thermal neutrons and intermediate
fast neutrons registrationbull Usable in the fields of Pu(Be) Po(Be) Cf and other
neutron sources as well as near nuclear reactors without neutron spectrum estimation
SPC ldquoDozardquoRadiation monitoring equipment
48 49
Dosimeters DVG-03D
DVGI-8D NEW PEN-TYPE PERSONAL IONIZATION CHAMBER DOSIMETERS
Measurement of personal dose equivalent Hp(10) of gamma and X-ray radiationbull Hp(10) of continuous and pulsed gamma and
X-ray radiation bull Electronic reader KSU-1bull Dosimeter DVG-03D with electronic ID bull Personal dose histories in the readerrsquos memorybull Readerrsquos connection with PC for database main-
tenance
Physical characteristicsDetector bull Ionization chamber
Measurement range bull 001 mSv divide 25 mSv
Energy range bull 0015 divide 25 MeV
Temperature range bull Reader KSU-1 +10 divide +50 ordmСbull Dosimeter DVG-03D minus 40 divide +50 ordmС
Electrical characteristicsPower supply bull Reader KSU-1 220 V 50 Hz built-in batteries bull Dosimeter DVG-03D four batteries CR 1025 bull Batteries life 3 yearsbull Readers interfaces RS-232USB 20
Mechanical characteristicsOverall dimensions weightbull Dosimeter DVG-03D Oslash 18times126 mm 005 kgbull Reader KSU-1 235times232times125 mm 28 kg
Reference standards Nuclear IEC 62387-1
DKG-02U ldquoARBITERrdquo WIDE RANGE GAMMA-DOSIMETER
Physical characteristicsDetectors bull GM counters
Measurement rangebull Dose-rate 01 μSvh divide 3 Svhbull Dose 1 μSv divide 100 Sv
Energy range bull 005 divide 3 MeV
Electrical characteristicsbull Power supply 2 alcaline batteries (type AA)bull Batteries life not less 200 hours
Mechanical characteristicsOverall dimensions weight bull 152times82times32 mm 03 kg
Environmental characteristicsbull Temperature range minus 20 divide +50 ordmCbull Humidity up to 90 at +25 ordmCbull Shock vibration and drop resistant
Reference standards Nuclear IEC 60846
Measurement of gamma radiation ambient equiva-lent dose H(10) and dose rate H(10)bull Audible signals (clicks) for radiation condition
estimationbull Analog scale for search modebull Audible and visual alarms of the excess of preset
dose and dose rate thresholds bull Shock-resistant water-proof easy decontamina-
tion casebull 100 measurement results memory with date and
time of measurementbull Indication of total dose accumulated during
exploitation time bull Indication of measurement result statistical
uncertainty
SPC ldquoDozardquoRadiation monitoring equipment
50 51
Physical characteristicsDetectors bull GM counter
Measurement rangebull Dose-rate 01 μSvh divide 3 mSvhbull Dose 1 μSv divide 02 Sv
Energy range bull 005 divide 3 MeV
Temperature range bull Minus 20 divide +50 ordmC
Electrical characteristicsbull Power supply 2 alcaline batteries 15 V (type AA)bull Batteries life not less 200 hours
Mechanical characteristicsOverall dimensions weight bull 122times74times29 mm 025 kg
Reference standards Nuclear IEC 60846
DKG-07D ldquoDROZDrdquoGAMMA-DOSIMETER
Measurement of gamma radiation ambient equiva-lent dose H(10) and dose rate H(10)bull Two independent measurement channels dose
and dose ratebull Audible signals (clicks) for radiation condition
estimationbull Continuous measurement with updating meas-
urement resultbull Measurement result can be obtained with any
desired statistical uncertainty (error)bull Automatic restart when radiation level sharply
changesbull Indication of statistical uncertainty (error) during
measurement process
Continuous measurement with updating measure-ment result
Automatic restart when radiation level sharply changes bull Gamma dose H(10) and dose-rate H(10) meas-
urementbull Beta and gamma contamination surveybull Indication of statistical uncertainty during the
measurementbull Continuous measurement with accuracy increas-
ing with time bull Automatic restart triggered by change of gamma
dose-ratebull Compensation of gamma count rate while meas-
uring beta radiationbull Indication of battery charge levelbull Audible signal of the excess of preset threshold
Physical characteristicsDetectors bull GM counter
Measurement range bull Dose-rate 01 microSvh divide 20 mSvhbull Dose 1 microSv divide 100 Svbull Beta flux density (for Sr-90+Y-90)
10 divide 105 cm-2 min-1
Energy range bull Gamma 005 divide 3 MeVbull Beta 01 divide 3 MeV
Temperature range bull Minus 20 divide +50 ordmC
MKS-15D ldquoSnegirrdquo backside
MKS-15D ldquoSNEGIRrdquoMULTI ndash PURPOSE RADIATION SURVEY METER
Reference standards Nuclear IEC 60846 IEC 60325
Electrical characteristicsbull Power supply 2 alcaline batteries (type AA)bull Battery life not less 400 hours
Mechanical characteristicsOverall dimensions weight bull 124times72times35 mm 035 kg
SPC ldquoDozardquoRadiation monitoring equipment
52 53
Physical characteristicsDetectorbull GM counter
Measurement range bull 01 μSvh divide 20 mSvh
Energy range bull 005 divide 30 MeV
Threshold setting range bull 03 μSvh divide 20 mSvh
Step change of the thresholdbull In the range 03 divide 10 μSvh with the step
001 μSvhbull In the range 10 divide 100 μSvh with the step
01 μSvhbull In the range 100 divide 2000 μSvh with the step
10 μSvh
Electrical characteristicsPower supply bull 220 V 50 Hz bull Relay output
Mechanical characteristicsProtection index bull IP 40
Overall dimensions weight bull 226times120times75 mm 07 kg
Alarmbull Sound alarm 80 divide 100 dBA at distance 1 mbull Visual alarm redbull Connection of the external alarm signaling unit
Reference standards Nuclear IEC 60846 IEC 60532
Continuous automatic monitoring of the ambient dose equivalent rate bull Measurement of gamma dose rate H(10)bull Audible and visual alarm signals for preset
thresholdsbull Switching on the external signaling or executive
devices
SRPS-05D GAMMA MONITOR
Measurement ofbull Gamma and X-ray personal dose equivalent
Hp(10)bull Neutron personal dose equivalent Hp(10)bull Lens dose equivalent Hp(3)bull Skin dose equivalent Hp(007)bull TLD reader day-to-day tests using built-in LEDbull No needs nitrogen for heating
Physical charachteristicsDetectors bull 7LiF Mg Ti (gamma beta)bull 6LiF Mg Ti (neutron)
Gamma and X-ray Hp(10) Measurement range bull 500 μSv divide 10 Sv
Energy range bull 0015 divide 30 MeV
Neutron Hp(10)Measurement range bull 01 mSv divide 100 mSv
Energy range bull 0025 eV divide 10 MeV
Beta and photons Hp(007) Hp(3) Measurement range bull 2 mSv divide 100 Sv
Energy range bull Beta 025 divide 35 MeVbull Photons lt15 keV
Mechanical characteristicsDosimeters overall dimensions weight bull Gamma Hp(10) DTL-2 holder - 62times26times16 mm
16 gbull DTU holder - 42times28times18 mm 8 gbull Lens Hp(3) face skin Hp(007) Oslash 32times16 mm 9 gbull Finger skin Hp(007) 90times20times2 mm 1 gbull Neutron gamma Hp(10) 48times40times20 mm 30 g
Reference standards Nuclear IEC 61066
DTL-2 DTU-2
MKD (A-type) DVNG-M
DOZA-TLD MULTIPURPOSE TLD SYSTEM
SPC ldquoDozardquoRadiation monitoring equipment
54 55
Continuous and pulsed gamma and X-ray dose H(10) and dose-rate measurementbull Alpha beta and gamma contamination surveybull Neutron dose H(10) and dose-rate measurementbull Gamma radiation flux density in boreholes and
liquid media measurement
Electrical characteristicsPower supply bull UIK-05 four C-size batteriesbull UIK-05-01 rechargeable batterybull UIK-06 rechargeable battery
Interfaces bull RS-232bull USB (via adapter)
bull Detector type automatic determination and corre-sponding measurement modes selection
bull Alarm threshold settings ndash for dose dose-rate alpha and beta contaminations
bull ldquoDetectrdquo and ldquoLocaterdquo modes for survey probes
Reference standards Nuclear IEC 60846 IEC 60325 IEC 61005 IEC 62363
Case
UIK-06 control unit165times78times48 mm 03 kg
DKS-96UNIVERSAL RADIATION SURVEY METER
UIK-05 control unit202times86times90 mm 10 kg
BDZA-96
BDZA-96B
BDZA-96M
BDZA-96S
BDZA-96T
EXTERNAL PROBES ALPHAALPHA BDZA-96Detector bull ZnS(Ag) 70 cm2
Measurement range (for Pu-239)bull 01 divide 104 min-1cm-2
Overall dimensions weightbull Oslash 130times240 mm 11 kg
ALPHA BDZA-96BDetector bull ZnS(Ag) 300 сm2
Measurement range (for Pu-239)bull 01 divide 2103 min-1cm-2
Overall dimensions weightbull Oslash 230times290 mm 40 kg
ALPHA BDZA-96MDetector bull ZnS(Ag) 10 сm2
Measurement range (for Pu-239)bull 01 divide 105 min-1cm-2
Overall dimensions weightbull Oslash 65times240 mm 09 kg
ALPHA BDZA-96SDetector bull ZnS(Ag) 30 сm2
Measurement range (for Pu-239)bull 01 divide 5104 min-1cm-2
Overall dimensions weightbull Oslash 90times240 mm 10 kg
ALPHA BDZA-96TDetector bull Silicon 5 сm2
Measurement range (for Pu-239)bull 01 divide 106 min-1cm-2
Overall dimensions weightbull Oslash 50times60 mm 015 kg
SPC ldquoDozardquoRadiation monitoring equipment
56 57
BETA BDZB-96Detector Scintillator 28 сm2
Measurement range (for Sr-90+Y-90)bull 10 divide 105 min-1cm-2
Energy rangebull 03 divide 30 MeV
Overall dimensions weightbull Oslash 90times230 mm 09 kg
BETA BDZB-99Detector bull GM counter 30 сm2
Measurement range (for Sr-90+Y-90)bull 20 divide 104 min-1см-2
Energy rangebull 012 divide 30 MeV
Overall dimensions weightbull Oslash 88times80 mm 04 kgbull Telescopic pole length 07 m
BETA BDZB-96BDetector bull GM counter 80 сm2
Measurement range (for Sr-90+Y-90)bull 3 divide 104 min-1сm-2
Energy rangebull 012 divide 30 MeV
Overall dimensions weightbull 150times200times110 mm 15 kg
BETA BDZB-96Sbull Detector GM counter 15 сm2
Measurement range (for Sr-90+Y-90)bull 10 divide 3104 min-1cm-2
Energy rangebull 012 divide 30 MeV
Overall dimensions weightbull Oslash 65times65 mm 03 kgbull Telescopic pole length 07 m
BDZB-96
BDZB-99
BDZB-96B
BDZB-96S
EXTERNAL PROBES BETA
GAMMA BDKS-96BDetector bull Tissue-equivalent scintillator Oslash 45times20 mm
Measurement rangebull Dose rate H(10) 01 μSvh divide 1 Svhbull Dose H(10) 01 μSv divide 10 Sv
Energy rangebull 0015 divide 10 MeV
Overall dimensions weightbull Oslash 60times250 mm 085 kg
GAMMA AND BETA BDKS-96SDetector bull Double GM counters
Measurement rangebull Gamma dose rate H(10) 01 μSvh divide 1 mSvhbull Gamma dose H(10) 01 μSv divide 10 Svbull Beta 10 divide 3104 min-1cm-2
Energy rangebull Gamma 005 divide 3 MeVbull Beta 012 divide 3 MeV
Overall dimensions weightbull Oslash 80times80 mm 035 kgbull Telescopic pole length 07 m
GAMMA BDMG-96Detector bull GM counters
Measurement rangebull Dose rate H(10) 01 μSvh divide 10 Svhbull Dose H(10) 01 μSv divide 10 Sv
Energy range bull 005 divide 3 MeV
Overall dimensions weightbull 40times250 mm 05 kgbull Telescopic pole length 07 m 4 m (by request)
EXTERNAL PROBES GAMMA
BDKS-96B
BDMG-96
BDKS-96S
SPC ldquoDozardquoRadiation monitoring equipment
58 59
GAMMA-SEARCH BDVG-96Detector bull Scintillator NaI(Tl) Oslash 63times63 mm
Measurement rangebull Flux density measurement range 4 divide 2000 s-1cm-2
bull Dose rate H(10) for Cs-137 01 divide 30 μSvhbull Sensitivity for Cs-137 3000 (pulsess-1)( μSvh-1)
Overall dimensions weightbull Oslash 88times400 mm 20 kgbull Modular pole length 16 m
GAMMA-SEARCH BDPG-96Detector bull Scintillator NaI(Tl) Oslash 25times40 mm
Measurement rangebull Flux density measurement range 10 divide 8000 s-1cm-2
bull Dose rate H(10) for Cs-137 01 divide 100 μSvhbull Sensitivity for Cs-137 500 (pulsess-1)( μSvh-1)
Overall dimensions weightbull 50times190times480 mm 10 kgbull Telescopic pole length 07 m
GAMMA-SEARCH BDPG-96MDetector bull Scintillator NaI(Tl) Oslash 18times30 mm
Measurement rangebull Flux density measurement range 10 divide 24000 s-1cm-2
bull Dose rate H(10) for Cs-137 01 divide 300 μSvhbull Sensitivity for Cs-137 200 (pulsess-1)( μSvh-1)
Overall dimensions weightbull Oslash 35times320 mm 05 kgbull Telescopic pole length 07 or 38 m
EXTERNAL PROBES GAMMA
BDVG-96
BDPG-96M
BDPG-96
EXTERNAL PROBESGAMMA BDKG-96 STAINLESS STEEL CASING FOR GEOLOGIC APPLICATIONS WELL LOGGINGDetector bull Scintillator NaI(Tl) Oslash 18times30 mm
Measurement rangebull Flux density measurement range 10 divide 105 s-1cm-2
bull Dose rate H(10) for Cs-137 5 divide 2104 μRhbull Sensitivity for Cs-137 200 (pulsess-1)( μSvh-1)
Overall dimensions weightbull Oslash 38times535 mm 36 kgbull Cable length 10 divide 1000 m
NEUTRON BDMN-96Detector bull Scintillator with ZnS(Ag)
Measurement rangebull Dose rate H(10) 01 μSvh divide 01 Svhbull Dose H(10) 01 μSv divide 10 Sv
Energy range bull 0025 eV divide 10 MeV
Overall dimensions weightbull Detector Oslash 54times200 mm 08 kgbull Moderator Oslash 245 mm 73 kg
NEUTRON-SEARCH BDKN-96Detector bull He-3 counter in polyethilene moderator
Measurement rangebull Dose rate H(10) for Pu-Be 01 μSvh divide 01 Svhbull Dose H(10) for Pu-Be 01 μSv divide 10 Sv
Energy range bull 0025 eV divide 14 MeV
Overall dimensions weightbull 295times142times100 mm 225 kg
BDKG-96M
BDMN-96
BDKN-96
SPC ldquoDozardquoRadiation monitoring equipment
60 61
bull No gas supply neededbull Clothing control detachable right hand detector bull Alpha detector optional connection bull Numeric and color (red green) indication of
control resultsbull LED sensor of hand-foot positioning for start of
measurementbull Automatic compensation of gamma background
and contamination of detectorbull Audible alarm signals of the excess of preset
thresholdsbull Measurement value indication min-1cm-2 or
Bqсm2
Reference standards Nuclear IEC 61098
RZB-05D HAND-FOOT-CLOTHING MONITOR
Physical characteristicsDetectors bull Gamma beta - GM countersbull Alpha - scintillatior ZnS(Ag)
Detecting nuclidesbull Alpha Pu-239 U-234 U-238bull Beta Sr-90+Y-90 F-18 Cs-137 Co-60 Tс-99 O-15
N-13 Sr-89 C-11 I-131 Na-22 Ru-106+Rh-106 Tl-204
bull Gamma Tc-99m I-123
Efficiencybull Alpha
Pu-239 40 U-234 25U-238 15
bull Beta Sr-90 +Y-90 40
Measurement range bull Alpha 1 divide 103 min-1cm-2 bull Beta 10 divide 103 min-1cm-2
bull Gamma 5103 divide 5106 min-1cm-2
Energy range bull Alpha 30 divide 80 MeV bull Beta 008 divide 35 MeV bull Gamma 005 divide 30 MeV
Operation temperature range bull Minus 10 divide +50 ordmС
Electrical characteristicsbull Power supply 220 V 50 Hz
Mechanical characteristicsOverall dimensions weight bull 740times750times1180 mm 45 kg
Versionsbull Withwithout alpha detectorbull Indication (min-1cm-2 ) or (Bqсm2)bull Detectors overall dimensions smbull Hand 178 х 235bull Foot 185 х 436
Whole body contamination monitor RZBA-04-04Mbull No gas supply neededbull Compensation for background gamma radiation
and contamination of detector unitsbull Individual threshold setting for each measure-
ment channelbull Visible and audible alarms ldquoCONTAMINATIONrdquo and
ldquoCLEANrdquo bull Indication of contaminated body parts on the
panel with image of the bodybull Optional remote alpha-detector
Physical characteristicsDetectors bull Beta - GM counters scintillatorsbull Alpha - scintillatior ZnS(Ag)
Measurement range bull Beta 5 divide 15000 min-1cm-2
bull Alpha 01 divide 10000 min-1cm-2
Energy range bull Beta 015 divide 25 MeV bull Alpha 40 divide 56 MeV
Operation temperature range bull +5 divide +50 ordmС
Electrical characteristicsPower supply bull 220 V 50 Hz
Interfaces bull RS-232bull RS-485
Mechanical characteristicsOverall dimensions weight bull 2650times940times930 mm 310 kg
Versionsbull Withwithout alpha detectorbull Indication (min-1cm-2 ) or (Bqсm2)
Reference standards Nuclear IEC 61098
RZBA-04-04MWHOLE BODY CONTAMINATION MONITOR
SPC ldquoDozardquoRadiation monitoring equipment
62 63
RZA-05DALPHA HAND-MONITOR
bull No gas supply needed bull Numeric and color (red green) indication of
control resultsbull LED sensor of hand- positioning for start of
measurementbull Audible alarm signals of the excess of preset
thresholdsbull Measurement value indication min-1cm-2 or
Bqсm2
Physical characteristicsDetectors alpha - scintillatior ZnS(Ag)
Efficiencybull Pu-239 20 bull U-234 14bull U-238 8
Measurement range bull 05 divide 105 min-1cm-2
Energy range bull 41 divide 90 MeV
Operation temperature range bull minus 10 divide +50 ordmС
Electrical characteristicsPower supply bull 220 V 50 Hz
Mechanical characteristicsOverall dimensions weight no more bull 740times1400times1450 mm 70 kg
Reference standards Nuclear IEC 61098
bull Simultaneous measurement of alphabeta activi-ties in the sample
bull Active shielding anti-coincidence background subtraction using GM counters
bull Lead shielding 30 mm
UMF-2000 LOW LEVEL ALPHA- BETA- COUNTER
Physical characteristicsDetectors bull Silicon specrometric detector 500 or 1000 mm2
Measurement range bull Alpha 001 divide 1000 Bq bull Beta 01 divide 3000 Bq
Energy range bull Alpha 35 divide 80 MeV bull Beta 005 divide 35 MeV
Electrical characteristicsPower supply bull 220 V 50 Hz
Interfaces bull RS-232bull USB
Mechanical characteristicsOverall dimensions weight bull 337times286times190 mm 22 kg
Versionsbull Detector area 500 mm2
bull Detector area 1000 mm2
UMF-2000 Detector area 1000 mm2
UMF-2000 Detector area 500 mm2
SpectraDec software for alpha-spectrometric measurements
SPC ldquoDozardquoRadiation monitoring equipment
64 65
DRK DOSE AREA PRODUCT METER
DRK-1bull Diagnostic reference level (DRL) of patients
determinationbull Suitable for all basic types of x-ray machines
Physical characteristicsDetector bull Plane-parallel ionization chamber
Measurement range bull 1 divide 104 cGycm2
Electrical characteristicsPower supply bull 220 V 50 Hz
DRK-1M-CTbull Measuring of dose length product
Physical characteristicsDetector bull Pencil Ionization Chamber
Measurement rangebull 05 divide 109 microGym
DRK-1Mbull Measuring of air kerma on sectional area of the
X-ray beam productbull Measuring of air kerma rate on area productbull Measuring of air kerma ratebull Measuring of air kerma
Physical characteristicsDetector bull Plane-parallel ionization chamber
Measurement rangebull 01 divide 109 microGym2
bull 06 divide 6104 microGym2cbull 30 divide 9105 microGycbull 30 divide 9991011 microGyReference standard IEC 60580 2003
bull Measurement of strontium-90 in the foodstuffs agricultural products etc
bull Measurement of gross beta activity in samplebull Self tests using built-in LED
ldquoPROGRESS-BETArdquo SCINTILLATION BETA SPECTROMETER
Physical characteristicsDetector bull Plastic scintillator Oslash70x10 mm
Sample bull Plate Oslash70 mmbull Weight up to 15 g
Energy range bull 02 divide 30 MeV
Minimum detectable activity of Sr-90 in a 10 g sample on a standard planchet Bqsamplebull In case of absence of K-40 in the sample 01 Bqbull In case the activity of K-40 till 5 Bqg 05 Bq
Electrical characteristics Interface bull USB
Mechanical characteristicsWeight bull No more 50 kg
Complete setBasic complete setbull Detector unit with plastic scintillator integrated
power supply amplifier ADC bull Lead shielding bull ldquoProgressrdquo software bull Сheck source for energetic calibration (Sr-90-Y-90) bull Planchet Oslash 70 mm (5 items) bull Sample dencification device bull Procedure manual for measurement of radio-
nuclidesrsquo activity using the scintillation beta spec-trometer ldquoProgressrdquo
Optional equipment and servicebull Personal computer and printer bull Calibrations for radionuclides not included in the
main library of radionuclides
Progress-Beta
Reference standards IEC 61562
SPC ldquoDozardquoRadiation monitoring equipment
66 67
bull Measurement of gamma activity in foodstuffs soil samples and others environmental objects
bull Identification of radionuclides in the sample bull Automatic correction for sample density bull Self-tests using built-in LED
ldquoPROGRESS-GAMMArdquoSCINTILLATION GAMMA SPECTROMETER
Physical characteristicsDetector bull NaI (Tl) Oslash63times63 mm
Validated measurement geometries bull Marinelli beakers (1 liter) Petri dishes (Oslash90 mm)
etc
Energy range bull 02 divide 30 MeV
Minimum detectable activity Bqsamplebull Cs-137 3 Bqbull Th-232 7 Bqbull Ra-226 8 Bq bull К-40 40 Bq
Electrical characteristics Interface bull USB
Mechanical characteristicsWeight bull No more 120 kg
Complete setBasic complete setbull Scintillation detector unit with NaI (Tl) detector
with integrated power supply amplifier and ADC bull Lead shielding 50 mm bull ldquoProgressrdquo software bull Сheck source for energy calibration (Cs-137 +
K-40)bull Marinelli beakers - 1 liter (5 items) bull Petri dishes Oslash 90 mm (5 items) bull Procedure manual for measurement of activity
of radionuclides using the scintillation gamma spectrometer ldquoProgressrdquo
Optional equipment and servicebull Kit for radon measurements including calibration
of ldquoIC-63rdquo geometry for counting the charcoal samples
bull Personal computer and printer bull Calibrations for user defined geometries bull Calibrations for radionuclides not included in the
main library of radionuclides
Progress-Gamma
Reference standards IEC 61563
ldquoPROGRESS-G(P)rdquoPORTABLE SCINTILLATION GAMMA SPECTROMETERbull Field measurements of gamma activity in environ-
mental objects without sampling (4π geometry)bull Laboratory measurement of gamma activity in
foodstuffs soil samples and others environmental objects
bull Identification of radionuclides in the sample bull Automatic correction for sample densitybull Tests using built-in LED
Physical charachteristicsDetector bull NaI (Tl) Oslash45times50 mmbull Lead shielding 20 mm
Validated measurement geometries bull Marinelli beakers (05 liter) Petri dishes (Oslash90 mm)
etc
Energy range bull 02 divide 30 MeV
Minimum detectable activity in 05-litre Marinelli beaker bull Cs-13710 Bqkgbull К-40100 Bqkgbull Ra-22618 Bqkg bull Th-23216 Bqkg
Minimum detectable activity in 30 min (4π geometry) bull Cs-137 2 Bqkgbull К-40 30 Bqkgbull Ra-226 4 Bqkg bull Th-232 3 Bqkg
Electrical characteristicsPower supply bull Rechargeable batterybull 220 V 50 Hz
Interface bull USB RS-232
Weight bull No more than 60 kg
Complete setBasic complete setbull Scinttillation detector unit with NaI(Tl) bull ldquoProgressrdquo softwarebull Сontrol unit ldquoSputnikrdquo for aquisition and analisys
of spectra with built-in memory for spectral databull Casebull Lead shielding (2 cm) for laboratory usebull 05-litre Marinelli beakers ndash 5 itemsbull Na-22 check sourcebull Power adapter BPS-01bull Operation manualbull Procedure manual for measurement of activity
of radionuclides using the scintillation gamma spectrometer ldquoProgressrdquo
Optional equipment and servicebull Kit for radon measurements with charcoalbull Built-in dose rate meterbull Additional memory (RAM) for storage of 64
spectrabull Additional power adapterbull Notebook and printer
Progress-Gamma
Reference standards IEC 61563
SPC ldquoDozardquoRadiation monitoring equipment
68 69
Physical characteristicsDetectorbull Scintillation detector ZnS (Oslash 60 mm)
Samplebull Thin sample - diameter up to 70 mm bull Preparation technique - electro-depositionbull Thick sample - diameter 70 mm weight
200300 mg bull Preparation technique - application of powders
(prepared by radiochemical concentration by water evaporation or by pounding of mineral samples) onto a planchet with the help of spirit
Energy rangebull 15 divide 8 MeV
Minimum detectable activitybull Thin samples no more than 910-3 Bqsamplebull Thick samples no more than 180 Bqkg
Mechanical characteristicsOverall dimensions weightbull 195times120times210 mm 34 kg
Complete setBasic complete setbull Alpha radiometer ldquoProgress-ARrdquobull Check source (uranium isotopes)
Set of accessoriesbull Procedure manual for measurements of radi-
oactivity using scintillation alpha radiometer ldquoProgress-ARrdquo
bull ldquoProgressrdquo software
ldquoProgress-ARrdquo
bull Measurement of gross activity of alpha emitting radionuclides in thin samples
bull Measurement of gross activity of alpha emitting radionuclides in thick samples
bull Measurement of activity deposited on aerosol filters
ldquoPROGRESS-ARrdquoALPHA RADIOMETER
Several fixed positions of the detector enable to perform measurements in various geometries and to estimate the content ofbull Cs-137 in the whole bodybull I-131 in thyroidbull Co-60 Cs-137 Mn-54 Cr-51 in lungsbull Database for storage of measurement data and
resultsbull Uncertainty calculations based on measurement
databull Self tests using built-in LED
ldquoPROGRESSrdquo WHOLE BODY COUNTER
Physical characteristicsDetectorbull scintillation detector NaI (Tl) Oslash63times63 mm
Energy rangebull 02 divide 28 MeV
Minimum detectable activitybull By Cs-137 in the whole body - 1200 Bqbull By I-131 in thyroid - 100 Bqbull By Co-60 Cs-137 Mn-54 Cr-51 in lungs - 200 Bq
Mechanical characteristicsWeight bull No more than 120 kg
Complete setBasic complete setbull Collimator with rotator and holderbull Detector with incorporated ADCbull Patient chair and table for collimatorbull Check source Na-22bull Procedure manual for lifetime measurement of
gamma-emitting radionuclidesrsquo activity in human body using the gamma-spectrometer of human radiation ldquoProgressrdquo
bull laquoProgressraquo software
Optional equipment and servicebull Program of internal radiation committed internal
radiation effective dose calculation by the stand-ard model
bull Background phantombull Personal computer and printer
Collimator with rotator and holder
SPC ldquoDozardquoRadiation monitoring equipment
70 71
bull Categorization of wastes for the purpose of fur-ther processing including wastes with unknown radionuclide composition
bull Measurements during the incoming waste inspec-tion (accepting for storage disposal)
bull Certification of unconditioned and conditioned wastes in closed containers without opening them (at nuclear plants or at facilities providing collection storage transportation conditioning processing temporal storage and final disposal of radioactive waste)
bull Activity measurement of extended objects in situ without opening the equipment
bull Activity measurement of extended objects after opening (for example assessment of tubes used for oil transportation)
MKG-01D ldquoSADOVNIKrdquoSPECTROMETRY SYSTEM
Physical charachteristicsDetectorbull Detector unit GEM (GMX) with HPGe detector and
multi-positioning cryostat CFG-PMOD4-7 with 7 litre Dewar
bull Dose rate probe BDMG-200
Energy range bull With GEM detector 004 divide 30 MeVbull With GMX detector 0005 divide 15 MeVbull Dose rate probe BDMG-200 ndash 005 divide 30 MeV
Measurement rangebull 110-7 divide 10 Svhbull Relative efficiency of detection (in photopeak) at
13325 MeV (Co-60) 10 divide 150
Electrical characteristicsPower supplybull 220 V 50 Hz
Interfacebull USB
Complete setBasic complete setbull Spectrometric detector unit GEM (GMX) with
HPGe detector and multi-positioning cryostat with 7 litre Dewar
bull Portable digital multichannel analyzer DigiDARTbull Dose rate probe BDMG-200bull Autonomous power supply unit with built-in
batterybull Industrial computer keyboardbull Laser range-finderbull Thermographic printerbull Web-camerabull Device equipped with stepper motor for position-
ing of the spectrometric detectorbull Calibration device with reference sources
(Am-241 Co-60 Ba-133 Eu-152) for energy calibration
bull Removable collimators with end capbull Measurement proceduresbull ldquoClasterrdquo software
bull Measurement of gross alpha activity of alpha-emitting radionuclides
bull Measurement of alpha-emitting radionuclides activity in thin-layer samples meeting alpha-spectrometry requirements
Physical characteristicsDetectorbull Silicon ion-implanted 450 mm2
bull Easy to decontaminate thin windowbull dead layer less than 015 μmbull Background count rate in the range 3 divide 9 MeVbull No more than 09 h-1cm-2 for 450 mm2 detector
Energy rangebull 2 divide 9 MeVbull Lower limit of measurement range (minimum
detectable activity) 01 Bqbull Background count rate no more than 100 counts
in 24 hours
Electrical characteristics Power supplybull 220 V 50 Hz
Interfacebull USB
Complete setBasic complete setbull Detector unit with vacuum measuring chamber
and vacuum control systembull Low noise vacuum pump (type 2FY-05B or
equivalent)bull Check sourcebull ldquoProgressrdquo softwarebull Vacuum tube
MKS-01A ldquoMULTIRAD-ASrdquoALPHA SPECTROMETER
SPC ldquoDozardquoRadiation monitoring equipment
72 73
UCRV-2AIRFLOW MONITOR
bull Monitor of the air flow through filter of centralized multichannel sampling system
bull Radiation monitoring system (RMS) integration for internal exposures determination
bull Volume and flow rate measurements of the air that have passed through a analytical filter
bull Bar-code for filter identificationbull Operation as either standalone unit or as a part of
the RMS
Physical characteristicsMeasurement range of air volume bull 001 divide 9999 m3
Operation temperature range bull minus 20 divide +50 ordmС
Electrical characteristicsPower supply bull 220 V 50 Hz
Interface bull RS-485
PVP-06PORTABLE AIR SAMPLER
Air Sampler PVP-06 is indispensable for monitoring the radiation situation where the concentration of radioactive aerosols in the air does not require a sta-tionary sampling equipment Sampling head PVP-06 provides easy change of filters and cartridges
Purposebull To monitor the concentration of radioactive aero-
sols in the air sites
Controlled aerosolsbull Alpha- and beta-active aerosolsbull Daughter products of decay of radon and thoronbull Iodine isotopes
Physical characteristicsTypes of filtersbull Aerosol AFA-RSP-20bull Iodine AFA SI-20
Flow rate bull 33∙10-4 ndash 233∙10-4 m3s (20 divide 140 l min)
Electrical characteristicsPower supply bull 220 V50 Hzbull The vehicle power supply 108 divide 145 Vbull Internal battery
Minimal working time on internal battery to recharge bull 8 hours
Power consumption (at a flow rate of 100 lmin) bull 40 VA
Environment characteristicsOperating temperature bull minus 10 divide +40 deg C
Maximum humidity bull 90
Pressure bull 860 to 1060 hPA
Noise generated by the pump bull lt 55 dBA at 1 m
Mechanical characteristicsDimensions weight bull 241 times 108 times 160 mm 28 kg
Case material bull Plastic
Complete setbull Air sampler PVP-06bull AC power adapterbull Filters AFA-RSP-20 - 100 pcsbull Packaging for filters - 40 pcsbull Casebull Operation manualbull Calibration certificate
Optional equimpient bull Kit for sampling sorption columns of activated
carbon Ř head of sorption columns with protective
covers Ř activated charcoal SKT-3 - 1 pkg (02 L) Ř charocoal samples SC-13 - 8 pcs
bull Car charger bull Tipod bull Shoulder strapbull Calibration stand bull Filters AFA SI-20 - 100 pcs
Consumablesbull Aerosol filters AFA RSP-20bull Iodine filters AFA SI-20
SPC ldquoDozardquoRadiation monitoring equipment
74 75
Calibration of gamma dose and dose rate meters
Calibration ofbull Ambient equivalent dose H(10) meters (Sv Svh)bull Personal equivalent dose Hp(10) meters (Sv Svh)bull Exposure dose X meters (R Rh)bull Two sources in irradiator bull Select source and collimator opening using
tumbler
UPG-P DESKTOP GAMMA BEAM IRRADIATOR
Physical characteristicsRange of reproduced dose rate bull 05 μSvh divide 10 mSvh (50 μRh divide 100 mRh)
Sources activities bull 6times106 6times108 Bq (02 20 mCi) Cs-137
Overall dimensions bull 1250times400times300 mm
Irradiator weight bull Not more than 37 kg
Calibration bench weight bull Not more than 15 kg
Reference standards IEC 60846 IEC 61526
Physical characteristicsDetectorbull Silicon
Measurement range EEC measurement bull Measurement range of radon EEC
10 divide 10bull106 Bqbullm-3
bull Measurement range of thoron EEC 05 divide 10bull104 Bqbullm-3
bull Air flow through the filter 100plusmn05 lmin
Concentration measurementbull Measurement range of radon-222 concentration
in air 10 divide 20bull106 cpsbull Measurement range of 216Po(ThA)
1bull10-3 divide 1bull102 cpsbull Air sampler flow rate
10plusmn02 lminbull Measurement range of radon-222 concentration
in water samples 6 divide 800 Bqbullkg-1
bull Measurement range of radon-222 flux from soil surface 20 divide 103 mBqsbullm2
bull Measurement range of radon-222 concentration with preliminary sampling of air using air sam-plers 20 divide 107 Bqbullm-3
bull Measurement range of radon-222 concentration in samples of soil air 103 divide 106 Bqbullm-3
Operation temperature range bull 1 divide 35 ordmC
Electrical characteristicsPower supply bull 80 VA
Mechanical characteristicsOverall dimensions weight bull 220times200times165 mm 36 kg
ldquoALPHARAD PLUSrdquoRADON THORON amp THEIR PROGENY MONITORbull Measurement of radon and thoron concentration
and effective equivalent concentration (EEC)bull In the airbull In the indoor air of residential public and industri-
al buildings and structuresbull Measurement of radon in drinking water sourcesbull Measurements of radon flux from the soil surface
at land plots allocated for construction of houses public buildings and industrial facilities
bull Measurements of radon concentration in soil air
Reference standards IEC 61577
SPC ldquoDozardquoRadiation monitoring equipment
76 77
UKPN-2M-D NEUTRON BEAM IRRADIATOR
Reference standards IEC 61005 61322
Calibration of neutron dose and dose rate meters
Calibration ofbull Ambient equivalent dose H(10) meters (Sv Svh)bull Personal equivalent dose Hp(10) meters (Sv Svh)bull Flux density of neutrons (cm-2∙s-1)bull Transfer container for temporary storage of
sources bull Red light signal of source working position
Physical carachteristicsRange of reproduced dose ratebull 20 divide 800 μSvh
Range of reproduced flux densitiesbull 10 divide 400 cm-2∙s-1
Type of a source in use bull Pu-Be
Activity of a source in usebull 24х1011 Bq (with density of 107 s-1)
Overall dimensions weight no morebull 3000x750x2000 mm 300 kg
Required room dimensionsbull not less than 7x3x3 m
Electrical characteristicsPower supply bull 220 V 50 Hz
Calibration of gamma dose and dose rate meters
Calibration ofbull Ambient equivalent dose H(10) meters (Sv Svh)bull Personal equivalent dose Hp(10) meters (Sv Svh)bull Exposure dose X meters (R Rh)bull Four sources in irradiator bull Select source and move to working position
return to storage position using special rodbull Transfer container for temporary storage of
sources bull Red light signal of source working position
UPGD-2M-DGAMMA BEAM IRRADIATOR
Physical characteristicsRange of reproduced dose rate bull 05 μSvh divide 50 mSvh (50 μRh divide 5 Rh)
Maximum activity of source bull 2times1011 Bq (50 Ci) Cs-137
Overall dimensionsbull Irradiator 800times500times500 mmbull Guide rails length 30 mbull Height 16 mbull Weight not more than 700 kgbull Required room dimensions not less than 7x3x3 m
Electrical characteristicsPower supply bull 220 V 50 Hz
UPGD-2M-D
Reference standards IEC 60846 IEC 61526 IEC 61066
SPC ldquoDozardquo
78 79
Contents
MEASURING UNITS
DBG-S11D wide range gamma area monitor 40
UDKS-100 gamma and X-ray area monitor 41
UDMN-100 neutron area monitor 41
ALARM UNITS
BAS-2 ldquoMICROrdquo external visual alarm 42
BZS-2 ldquoMicrordquo external audible alarm 42
Illuminated warning signs 43
ldquoImpulsrdquo external display unit 43
UIM-3D area monitor count rate meter 44
DKG-05D personal gamma dosimeter 46
DVS-02D gamma-neutron personal electronic dosimeter 47
DVGI-8D new pen-type personal ionization chamber dosimeters 48
DKG-02U ldquoARBITERrdquo wide range gamma-dosimeter 49
DKG-07D ldquoDROZDrdquo gamma-dosimeter 50
MKS-15D ldquoSNEGIRrdquo multi ndash purpose radiation survey meter 51
SRPS-05D gamma monitor 52
DOZA-TLD multipurpose TLD system 53
DKS-96 universal radiation survey meter 54
EXTERNAL PROBES ALPHA
Alpha BDZA-96 55
Alpha BDZA-96B 55
Alpha BDZA-96M 55
Alpha BDZA-96S 55
Alpha BDZA-96T 55
EXTERNAL PROBES BETA
Beta BDZB-96 56
Beta BDZB-99 56
Beta BDZB-96B 56
Beta BDZB-96S 56
EXTERNAL PROBES GAMMA
Gamma BDKS-96B 57
Gamma and beta BDKS-96S 57
Gamma BDMG-96 57
EXTERNAL PROBES GAMMA
Gamma-search BDVG-96 58
Gamma-search BDPG-96 58
ContentsRadiation monitoring systemldquoPELIKANrdquo Radiation monitoring system (RMS) 6
BDMG-101 high range gamma area monitor 10
DBG-S11D wide range gamma area monitor 11
BDRG-52 high range gamma area monitor for accident and post-accident conditions 12
UDGP-01 Liquid technological environments monitor 13
UDMN-100 neutron area monitor 14
UDKG-100 Wel Liquid gamma monitor 14
BOP-1M data processing and transmission unit 15
UDA-1AB particulate monitor 16
UDG-1B noble gas monitor 17
UDG-03D noble gas monitor 18
UDI-1B iodine monitor 19
UDGB-01 noble gasesH-3C-14 monitor 20
UDGP-01 steam generator leakage monitor 21
UPPVM air flow parameters monitor 22
ldquoIMPULSrdquo external display unit 23
BI-2 remote display amp alarm unit 24
BASBAS-1s external alarm 25
SKGAV stack monitor 26
RMS software 28
RMS workstation ndash operator console 29
Configurator software 29
RM RACK radiation monitoring rack 30
SRKS-01D criticality accident alarm system 32
ldquoATLANT-Mrdquo environmental radiation monitoring system 34
ldquoBREEZErdquo high-volume air sampler 35
ldquoGAMMA-SENSORrdquo gamma-survey system 36
Radiation monitoring equipmentAREA MONITOR ldquoFREGATrdquo 38
BPI-1D local display unit 39
80
Gamma-search BDPG-96M 58
Gamma BDKG-96 stainless steel casing for geologic applications well logging 59
EXTERNAL PROBES NEUTRON
Neutron BDMN-96 59
Neutron-search BDKN-96 59
RZB-05D Hand-foot-clothing monitor 60
RZBA-04-04M whole body contamination monitor 61
RZA-05D alpha hand-monitor 62
UMF-2000 low level alpha- beta- counter 63
DRK dose area product meter 64
ldquoPROGRESS-BETArdquo scintillation beta spectrometer 65
ldquoPROGRESS-GAMMArdquo scintillation gamma spectrometer 66
ldquoPROGRESS-G(P)rdquo portable scintillation gamma spectrometer 67
ldquoPROGRESS-ARrdquo alpha radiometer 68
ldquoPROGRESSrdquo whole body counter 69
MKG-01D ldquoSADOVNIKrdquo spectrometry system 70
MKS-01A ldquoMULTIRAD-ASrdquo alpha spectrometer 71
UCRV-2 airflow monitor 72
PVP-06 portable air sampler 73
ldquoALPHARAD PLUSrdquo radon thoron amp their progeny monitor 74
UPG-P desktop gamma beam irradiator 75
UPGD-2M-D gamma beam irradiator 76
UKPN-2M-D neutron beam irradiator 77
Radiation monitoring system SPC ldquoDozardquo
6 7
More than 100 Radiation Monitoring Systems ldquoPelikanrdquo are installed and operating successfully at facilities representing different industries including research reactors nuclear power plants and the icebreaker ldquo50 Years of Victoryrdquo
FeaturesThe RMS ldquoPelikanrdquo constitutes a complex of independent units (intended for measurement of different parameters) that are interconnected into common information network The RMS network
is built using Ethernet IEEE 8023 technology it accommodates measurement devices and workstations as clients The network includes two servers (main and hot standby) or alternatively it can have no server at all The RMS allows performing all commutations necessary for repair or calibration of measurement units in hot mode without interrupting normal network operation
ldquoPELIKANrdquoRADIATION MONITORING SYSTEM (RMS)
Major users of ldquoPelikanrdquo RMS system are Nuclear Power Plants in Russia Ukraine China and India as well as Rosatom Rospotrebnadzor Ministry of Emergency Situations Rosstandard Ministry of Health Ministry of Defense Russian Railways laboratories and other companies and organizations
bull GMP ldquoZvesdochkardquo Severodvinskbull Mining and Chemical Complex Zheleznogorskbull Institute of Physics and Power Engineering
Obninskbull Russian Research Institute of Technical Physics
Sarov
REFERENCE
bull Leningrad NPPbull laquoAtomflotraquobull ldquoZvesdardquo factory Bolrsquoshoy Kamenrsquobull Petersburg Nuclear Physics Institutebull Civil Security Department Moscowbull ldquoRosatomrdquo Corporation MosNPO ldquoRadonrdquobull ldquoRosatomrdquo Corporation ldquoSNIIP-Systematomrdquobull ldquoRosenergoatomrdquo Concern Moscowbull Norilsk Mining and Smelting producerbull Russian Research Institute ldquoVNII Avtomatikardquo
Moscowbull Kudankulam NPP Indiabull Tianwan NPP China
Radiation monitoring system SPC ldquoDozardquo
8 9
SKGAV Stack monitor
UPPVM Air flow parameters monitor
RM Rack
UDG-1B Noble gas monitor
UDGB-01Noble gasesH-3C-14
monitor
UDA-1AB Particulate monitor
UDI-1BIodine monitor
UDGP-01 Steam generator leakage
monitor
RMSworkstation
Ethernet switch
Ethe
rnet
RS
-485
RMS workstationServer
DBG-S11D Wide range gamma area monitor
BDMG-101 High range gamma area monitor
UDMN-100 Neutron area monitor
BDRG-52 High range gamma area monitor
BASBAS-1s External alarm
BOP-1M Data processing and
transmission unit
RADIATION MONITORING SYSTEM
Ethe
rnet
RS
-485
BI-2 Remote display amp alarm unit
ldquoImpulsrdquoExternal Display Unit
UDKG-100 Wel Liquid gamma monitor
Ethernet RS-485 Ethernet RS-485
UDG-03D Noble gas monitor
UDGP-01 Liquidtechnological environment monitor
Radiation monitoring system SPC ldquoDozardquo
10 11
bull Continuous automatic monitoring of the ambient dose equivalent rate
bull Нigh temperature range (up to 120 degC)
BDMG-101 HIGH RANGE GAMMA AREA MONITOR
Physical characteristicsbull detector ndash ionization chambers
Measurement rangebull MIC-1 5∙10-5 divide 200 Svhbull MIC-2 5∙10-4 divide 1000 Svhbull MIC-3 1∙10-5 divide 100 Gyhbull MIC-4 5∙10-3 divide 10000 Gyh
Energy rangebull 005 divide 30 MeV
temperature rangebull ionization chamber module MIC-1
minus 30 divide +120 degCbull electrometric module MIC-2 MIC-3 MIC-4 ME
minus 30 divide +60 degC
Electrical characteristicsbull interfaces RS-485bull cable length between MIC and ME up to 30 m
Mechanical characteristicsbull Protection index IP 65
Overall dimensions weightbull ME Oslash105times293 mm 23 kgbull MIC-1 Oslash85times206 mm 12 kgbull MIC-2 Oslash45times156 mm 03 kgbull MIC-3 Oslash136times226 mm 09 kgbull MIC-4 Oslash35times92 mm 02 kg
BOP-1M
Reference standards Nuclear IEC 60846 IEC 60532
DBG-S11D WIDE RANGE GAMMA AREA MONITOR
Continuous automatic monitoring of the ambient dose equivalent rate
Physical characteristicsbull Detector ndash GM counters
Measurement rangebull DBG-S11D 01 μSvh divide 10 mSvhbull DBG-S11D-01 01 μSvh divide 10 Svhbull DBG-S11D-02 01 μSvh divide 100 Svh
Energy rangebull 005 divide 30 MeV
Temperature range bull minus 40 divide +50 ordmC
Electrical characteristicsbull Interfaces RS-485 USB
Mechanical characteristicsbull Protection index IP 68bull Paint decontaminable
Overall dimensions weightbull DBG-S11D Oslash 68times141 mm 065 kg bull DBG-S11D-01 Oslash 68times179 mm 07 kgbull DBG-S11D-02 Oslash 68times179 mm 07 kg
Versionsbull DBG-S11Dbull DBG-S11D-01bull DBG-S11D-02
BOP-1M
Reference standards Nuclear IEC 60532
Versionsbull stainless steel 100 cm2 ionization chamber
module (MIC-1) and electrometric module (ME)bull stainless steel 20 cm2 ionization chamber module
(MIC-2) and electrometric module (ME)bull duralumin 500 cm2 ionization chamber module
(MIC-3) and electrometric module (ME)bull titanium 2 cm2 ionization chamber module
(MIC-4) and electrometric module (ME)
Radiation monitoring system SPC ldquoDozardquo
12 13Reference standards EMC IEC 61010 IEC 61000-6-2 Seismic IEC 60980
bull Continuous automatic monitoring of the ab-sorbed dose rate
bull Monitoring inside containmentbull Delivery assembled detector and communication
linebull Communication line include inter wall protective
tubebull Hermetic communication line filled dry nitrogen
Physical characteristicsbull detector - stainless steel ionization chamber
Measurement range bull 10-3 divide 105 Gyh
Energy range bull 006 divide 30 MeV
Temperature range bull detector
0 divide 207 ordmC continuous
250 ordmC during 1 hour bull electrometric module 0 divide +60 ordmC
Detector operating pressure bull 07 МPa
Electrical characteristicsbull Interfaces RS-485bull detector-electrometric module cable length up
to 70 m
BDRG-52 HIGH RANGE GAMMA AREA MONITOR FOR ACCIDENT AND POST-ACCIDENT CONDITIONS
Ionization chamber
Mechanical characteristicsProtection index bull detector - IP 65bull electrometric module - IP 23bull Paint stainless steel
Overall dimensions weight bull detecting unit Oslash50х220 mm 3 kgbull inter wall protective tube Oslash 159 length (by order)
1200 ndash 1600 mm 60 kgbull electrometric module 420x420x120 mm 8 kg
Reference standards Nuclear IEC 60951 EMC IEC 61010 IEC 61000-6-2 Seismic IEC 60980
Continuous monitoring of technological environ-ments liquid couples sludges etc bull On line gamma spectrometry
Physical characteristicsbull Detector ndash scintillator CsI NaI
Measurement range bull Gamma-activity 10bull104 divide 20bull108 Bqm3
Energy range bull gamma 005 divide 15 MeV
Temperature range bull minus 10 divide +80 ordmС
UDGP-01 LIQUID TECHNOLOGICAL ENVIRONMENTS MONITOR
Electrical characteristicsbull Interfaces RS-232 RS-485 Ethernetbull programmable relay output (SPDT relay)
Mechanical characteristicsbull Protection index IP 65bull Paint decontaminable
Overall dimensions weight bull Detector unit
CsIOslash 60x360 mm17 kg NaIOslash 35x750 mm26 kg
bull Data processing and transmission unit BOP-1sp 280x220x114mm 43 kg
Alarmbull Sound alarm 80 divide 100 dBA at distance 1 mbull Visual alarm green yellow redbull Connection of the external alarm unit of ldquoBASrdquo
type
Radiation monitoring system SPC ldquoDozardquo
14 15
BOP-1M DATA PROCESSING AND TRANSMISSION UNIT
bull Processing of data incoming from detecting blocks UDMN-100 DBG-S11D UDKG-100 BDMG-101 BDRG-52
bull Data transmission to the network bull Data transmission to the mobile computer bull Storage of thresholds values and parameters of
detecting blocksbull Power supply and diagnostics of detecting blocks bull Generation of the alarm signals of the excess of
preset thresholdsbull Data backup in the non-volatile memory
Physical characteristicsbull Quantity of joined detecting blocks and alarm
units ndash up to 20bull Temperature range minus 40 divide +50 ordmC
Electrical characteristicsbull Power supply 85 divide 260 V 47 divide 440 Hzbull Interfaces RS-232 RS-485 Ethernet bull programmable relay output (SPDT relay)
Mechanical characteristicsbull Protection index IP 65 bull Paint decontaminable
Overall dimensions weightbull 298times220times114 mm 5 kg
Reference standards EMC IEC 61010 IEC 61000-6-2 Seismic IEC 60980
Continuous automatic monitoring of the neutron-radiations ambient dose equivalent ratebull Spherical polyethylene moderator Oslash 239 mm
UDMN-100 NEUTRON AREA MONITOR
Physical characteristicsbull detector ndash scintillator ZnS(Ag) Li-6
Measurement range bull 01 μSvh divide 01 Svh
Energy range bull 0025 eV divide 100 MeV
Temperature range bull minus 45 divide +50 ordmC
Electrical characteristicsbull Interfaces RS-485
Reference standards Nuclear IEC 61005 IEC 61322 EMC IEC 61010 IEC 61000-6-2 Seismic IEC 60980
UDKG-100WEL LIQUID GAMMA MONITOR
Mechanical characteristicsbull Protection index IP 65bull Paint decontaminable
Overall dimensions weight bull 428times258times347 mm 115 kg
Continuous automatic monitoring of the gamma radiation flux Operation in the rocks ore liquid media and sludge
Physical characteristics bull detector ndash NaI (Tl) Oslash 18x30 mm
Measurement range bull 40 divide 8104 s-1cm-2
Energy range bull 01divide 30 MeV
Temperature rangebull minus 40 divide +50 degC
Electrical characteristics bull Interfaces RS-485
Mechanical characteristics bull Protection index
Ř BDKG-100 IP 68 Ř Interface block BS-16 IP 65
bull Paint stainless steel bull Overall dimensions weight
Ř Detector unit BDKG-100 Oslash 38times530 mm 3 kg Ř Interface block BS-16 176times80times64 07 kg
Radiation monitoring system SPC ldquoDozardquo
16 17
UDG-1B NOBLE GAS MONITOR
Continuous automatic monitoring of the beta-emit-ting radioactive gases concentration in the working air and in the air in ventilation ducts and stacksbull Gamma background compensation bull Audible and visual alarm signals of the excess of
preset thresholds bull Periodic calibration by means of standard beta-
source
Physical characteristicsbull Silicon detectors (2 pcs for measurement and for
background compensation)bull Air flow rate 10 divide 100 lminbull Operation temperature range minus 10 divide +50 ordmС
Measurement range bull 104 divide 6109 Bqm3
Energy range bull 008 divide 30 MeV
Electrical characteristicsbull Power supply 85 divide 260 V 47 divide 440 Hzbull Interfaces RS-232 2timesRS-485 Ethernetbull programmable relay output (SPDT relay)bull Analog output 4-20 mA (optional)
Mechanical characteristicsbull Protection index IP 65bull Paint decontaminable
Overall dimensions weight bull Stationary version 395times240times304 mm 295 kgbull Mobile version with pump unit BN-1
395times468times950 mm 543 kg
Alarmbull Sound alarm 80 divide 100 dBA at distance 1 mbull Visual alarm green yellow red
Mobile version with pump unit BN-1
Stationary version
Reference standards Nuclear IEC 60761 IEC 62302 EMC IEC 61010 IEC 61000-6-2 Seismic IEC 60980
bull Connection of the external alarm unit ldquoBASrdquo type
Versionsbull Stationary versionbull Stationary version with pump unit BN-1bull Mobile version with pump unit BN-1
UDA-1AB PARTICULATE MONITOR
Stationary version
Continuous automatic monitoring of the alpha- and beta- radioactive aerosol concentration in the work-ing air and in the air in ventilation ducts and stacksbull Radon toron progenies and gamma background
compensation bull On line alpha spectrometrybull Audible and visual alarm signals of the excess of
preset thresholds bull Control of electromagnetic valves when operating
with the external air sampling linebull Control of pump unit bull Periodic calibration by means of standard beta-
and alpha-sources
Physical characteristicsbull Silicon specrometric detectors (2 pcs for measure-
ment and for background compensation)bull Filter tape types LFAS FSLWbull Tape consumption (when continuous operation)
10 m50 daysbull Air flow rate 10 divide 100 lmin bull Operation temperature range minus 10 divide +50 ordmС
Measurement range bull Alpha 10-2 divide 2105 Bqm3 bull Beta 10-1 divide 106 Bqm3
Energy range bull Alpha 30 divide 90 MeV bull Beta 005 divide 30 MeV
Electrical characteristicsbull Power supply 85 divide 260 V 47 divide 440 Hzbull Interfaces RS-232 2timesRS-485 Ethernet bull Programmable relay output (SPDT relay)bull Analog output 4-20 mA (optional)
Mechanical characteristicsbull Protection index IP 65bull Paint decontaminable
Overall dimensions weight bull Stationary version 389times260times304 mm 156 kg bull Mobile version with pump unit BN-1
389times468times950 mm 384 kg
Alarmbull Sound alarm 80 divide 100 dBA at distance 1 mbull Visual alarm green yellow redbull Connection of the external alarm unit ldquoBASrdquo type
Versionsbull Stationary versionbull Stationary version with pump unit BN-1bull Mobile version with pump unit BN-1
Reference standards Nuclear IEC 60761 IEC 61172 EMC IEC 61010 IEC 61000-6-2 Seismic IEC 60980
Mobile version with pump unit BN-1
Radiation monitoring system SPC ldquoDozardquo
18 19
Physical characteristicsbull Scintillation detectors CsI(Tl) (2 pcs for measure-
ment and for background compensation)bull Cartridge activated charcoal
Measurement range bull 37 divide 37106 Bqm3
Energy range bull 006 divide 30 MeVbull Air flow rate 20 divide 40 lminbull Operation temperature range minus 10 divide +50 ordmС
Electrical characteristicsbull Power supply 85 divide 260 V 47 divide 440 Hzbull Interfaces RS-232 2timesRS-485 Ethernetbull Programmable relay output (SPDT relay)bull Analog output 4-20 mA (optional)
Mechanical characteristicsbull Protection index IP 65bull Paint decontaminable
Overall dimensions weight bull Stationary version 448times323times479 mm 35 kgbull Mobile version with pump unit BN-1
448times468times950 mm 578 kg
Reference standards Nuclear IEC 60761 IEC 61171 EMC IEC 61010 IEC 61000-6-2 Seismic IEC 60980
Alarmbull Sound alarm 80 divide 100 dBA at distance 1 mbull Visual alarm green yellow redbull Connection of the external alarm unit of ldquoBASrdquo
type
Versionsbull Stationary versionbull Stationary version with pump unit BN-1bull Mobile version with pump unit BN-1
Сontinuous automatic monitoring radioiodine concentration in the air at working places and in ventilation ducts and stacksbull Measurement of volumetric activity of radionu-
clides I-131 I-132 I-133 I-135 in the airbull On line gamma spectrometrybull Gamma background compensation bull Performance self-test by means of Am-241 check
source implanted into the detectorbull Audible and visual alarm signals of the excess of
preset thresholdsbull Periodic calibration by means of standard source
UDI-1B IODINE MONITOR
Physical characteristicsbull Silicon detector 2 pcs (for measurement and for
background rejection)bull Air flow rate 10 divide 100 lminbull Operation temperature range minus 10 divide +50 ordmС
Measurement range bull 104 divide 11010 Bqm3
Energy rangebull 006 divide 30 MeV
Electrical characteristicsbull Power supply 120 Vbull Interface RS-485
Mechanical characteristicsbull Protection index IP 65bull Paint decontaminable
Overall dimensions weight bull 474х246х243 mm 295 kg
UDG-03D NOBLE GAS MONITOR
Measurement of volumetric activity of beta-emitting radioactive gases (argon krypton xenon) adapted to the measurement of the rapidly changing volume activity in various technological processesbull Gamma background compensationbull Periodic calibration by means of standard beta-
source
Reference standards Nuclear IEC 60761 IEC 62302 EMC IEC 61010 IEC 61000-6-2 Seismic IEC 60980
Radiation monitoring system SPC ldquoDozardquo
20 21
Continuous automatic monitoring of steam genera-tor primary to secondary leakagebull On line gamma spectrometrybull N-16 monitoringbull Performance self-test by means of Am-241 check
source implanted into the detectorbull Audible and visual alarm signals of the excess of
preset thresholds
Physical characteristics
UDGP-01 STEAM GENERATOR LEAKAGE MONITOR
bull detector ndash scintillator CsI Oslash 40х100 mm
Measurement range bull High energy gamma-activity (N-16)
15bull103 divide 20bull108 Bqm3
bull General gamma-activity 10bull104 divide 20bull108 Bqm3
Energy range bull General gamma 005 divide 15 MeV bull in integral spectral band of energy
5000 divide 7200 keV bull temperature range minus 10 divide +80 ordmС
BOP-1SP
Electrical characteristicsbull Power supply 85 divide 260 V 47 divide 440 Hzbull Interfaces RS-232 RS-485 Ethernetbull programmable relay output (SPDT relay)
Mechanical characteristicsbull Protection index IP 65bull Paint decontaminable
Overall dimensions weight bull Detector unit Oslash 60x360 mm17 kgbull Data processing and transmission unit BOP-1sp
280x220x114mm 43 kgbull Collimator Oslash 350x455 mm 150 kg
Alarmbull Sound alarm 80 divide 100 dBA at distance 1 mbull Visual alarm green yellow redbull Connection of the external alarm unit of ldquoBASrdquo
type
Reference standards Nuclear IEC 61453 EMC IEC 61010 IEC 61000-6-2 Seismic IEC 60980Reference standards Nuclear IEC 60761 IEC 60710 IEC 60951-2 EMC IEC 61010 IEC 61000-6-2 Seismic IEC 60980
Ionization chambe 10 liters
UDGB-01T1
Physical characteristicsbull Detectors - stainless steel ionization chambersbull Air flow rate 10 divide 100 lminbull Operation temperature range minus 10 divide +50 ordmС
Volumes of ionization chambers bull UDGB-01T UDGB - 01T1 100 litersbull UDGB-01T2 01 liter
Measurement range (Kr-85) bull UDGB-01T UDGB-01T1 10104 divide 50109 Bqm3
bull UDGB-01T2 109 divide 501014 Bqm3
Measurement range (H-3) bull UDGB-01T UDGB-01T1 50104 divide 50109 Bqm3
bull UDGB-01T2 50109 divide 501014 Bqm3
Electrical characteristicsbull Power supply 85 divide 260 V 47 divide 440 Hzbull Interfaces RS-232 2timesRS-485 Ethernetbull Programmable relay output (SPDT relay)bull Analog output 4-20 mA (optional)
Mechanical characteristicsbull Protection index IP 23bull Paint decontaminable
Continuous automatic monitoring of the beta-emitting radioactive gases including tritium and carbon-14 concentration in the air at working places and in ventilation ducts and stacksbull Audible and visual alarm signals of the excess of
preset thresholds bull Monitoring of the noble gase activity in gaseous
effluents and ventilation air for accident and post-accident conditions
Overall dimensions weight bull UDGB-01T 381times343times716 mm 30 kgbull UDGB-01T1 260times320times175 mm 125 kgbull Ionization chamber 100 liters Oslash 250times600 mm
6 kgbull UDGB - 01T2 381times343times716 mm 27 kg
Alarmbull Sound alarm 80 divide 100 dBA at distance 1 mbull Visual alarm green yellow redbull Connection of the external alarm unit ldquoBASrdquo type
Versionsbull UDGB-01T - with built-in ionization chamber
100 litersbull UDGB-01T2 - with built-in ionization chamber
01 literbull UDGB-01T1 - with remote ionization chamber
100 liters
UDGB-01NOBLE GASESH-3C-14 MONITOR
Radiation monitoring system SPC ldquoDozardquo
22 23
Physical characteristicsLength of communication cablebull up to 1200 m
Character height bull ldquoImpuls-910-Rrdquo 100 mmbull ldquoImpuls-915-D4Srdquo 150 mmbull ldquoImpuls-927-D4Srdquo 270 mm
Operating temperature rangebull ldquoImpuls-910-Rrdquo 0 divide +50 ordmCbull ldquoImpuls-915-D4Srdquo ldquo-927-D4Srdquo minus 40 divide +50 ordmC
Electrical characteristicsbull Power supply 220 V 50 Hz
Mechanical characteristicsProtection index bull ldquoImpuls-910-R IP 44bull ldquoImpuls -915-D4Srdquo ldquo-927-D4Srdquo IP 65
Overall dimensions weight bull ldquoImpuls-910-Rrdquo 400times160times60 mm 3 kgbull ldquoImpuls -915-D4Srdquo 815times250times80 mm 5 kgbull ldquoImpuls -927-D4Srdquo 1250times330times80 mm 5 kg
ldquoIMPULSrdquoEXTERNAL DISPLAY UNIT
Display of data received from monitors of RMS
External display unit ldquoImpuls-910-Rrdquo
Reference standards EMC IEC 61010 IEC 61000-6-2 Seismic IEC 60980
Continuous monitoring of the flow rate temperature and humidity of the gas flowbull Definition of air volume flow rate in stacks taking
into account temperature and humidity of the air
UPPVM AIR FLOW PARAMETERS MONITOR
Physical characteristicsMeasurement range bull air flow velocity 1 divide 20 msbull air temperature 0 divide +80 ordmСbull air humidity 10 divide 95
Electrical characteristicsbull Power supply 220 V 50 Hz bull Interfaces RS-232 Ethernet
Mechanical characteristicsProtection index bull BSPP-1st BSPP-1tv BOP-1s IP 65bull PP-st IPTV IP 54bull Paint decontaminable
Overall dimensions weight bull air velocity probe PP-st 60times38times136 mm 015 kgbull Interface block BSPP-1st 125times155times73 mm 07 kgbull air temperature and relative humidity probe
IPTV-056-A 333times100times60 mm 07 kgbull Interface block BSPP-1tv 125times155times73 mm 07 kgbull Data processing and transmission unit BOP-1s
280x233x111 mm 8 kg
Reference standards Nuclear ISO 2889 EMC IEC 61010 IEC 61000-6-2 Seismic IEC 60980
BOP-1S
Radiation monitoring system SPC ldquoDozardquo
24 25
BASBAS-1S EXTERNAL ALARM
Generation of audible and visual signals of the excess of preset thresholds RMS monitorsbull Audible alarm 80 divide 100 dBA at distance 1 mbull Visual alarm green yellow red
Distance from RMS monitorbull BAS up to 20 mbull BAS-1s up to 1200 m
Power supply bull 220 V 50 Hz
Overall dimensions weight bull BAS 145times108times460 mm 18 kg bull BAS-1s 166times109times466 mm 18 kg
Reference standards EMC IEC 61010 IEC 61000-6-2 Seismic IEC 60980
Physical characteristicsLength of communication cablebull up to 1200 m
Displayed page size bull 4 lines of 20 characters
Volume of loaded information bull 10 pages
Change of pagesbull programmed or by pressing a button
Operating temperature rangebull minus 40 divide +50 ordmC
Electrical characteristicsbull Power supply 9 divide 18 VDCbull Interfaces RS-485
Mechanical characteristicsbull Protection index IP 65bull Overall dimensions weight 222times164times73 mm
40 kg
BI-2 REMOTE DISPLAY amp ALARM UNIT
bull Display of data received from monitors of RMSbull Audible and visual alarms on exceeding preset
thresholds of the RMS equipment bull Individual threshold setting for each measure-
ment channelbull Audible alarm 80 divide 100 dB at a distance of 1 m bull Visual alarm red yellow green
Reference standards EMC IEC 61010 IEC 61000-6-2 Seismic IEC 60980
Radiation monitoring system SPC ldquoDozardquo
2726
Electrical characteristicsbull Power supply 220 V 50 Hz bull Interfaces RS-232 RS-485 Ethernetbull programmable relay output (SPDT relay)
Alarmbull Sound alarm 80 divide 100 dBA at distance 1 mbull Visual alarm green yellow redbull Connection of the external alarm unit ldquoBASrdquo type
Related monitors and equipmentsbull UDA-1AB particulate monitorbull UDG-1B noble gas monitorbull UDI-1B iodine monitorbull UPPVM air flow parameters monitorbull Sampling and sample separation rack
Air flow parameters monitor rack
Reference standards Nuclear IEC 60761 IEC 61171 IEC 61172 IEC 62302 ISO 2889 EMC IEC 61010 IEC 61000-6-2 Seismic IEC 60980
Sampling and sample separation rack
Continuous monitoring of radioactivity in gaseous effluentsbull Automatic monitoring of the alpha- and beta-
radioactive aerosol noble gas and radioiodine concentrations in the air in ventilation ducts and stacks
bull Monitoring of the flow rate temperature and humidity of the gas flow
bull Separation of gaseous effluent into targeted fractions by means of a two-stage filter
bull Reversion of gas after analysis to the ventilation system
Physical characteristics
Particulate (UDA-1AB)bull Silicon specrometric detectors (2 pcs for measure-
ment and for gamma-background compensation) bull Filter tape types LFAS FSLWbull Tape consumption (when continuous operation)
10 m50 days
Measurement range bull Alpha 10-2 divide 2105 Bqm3 bull Beta 10-1 divide 106 Bqm3
Energy range bull Alpha 30 divide 90 MeV bull Beta 005 divide 30 MeV
Noble gas (UDG-1B)bull silicon detectors (2 pcs for measurement and for
gamma-background compensation)
Measurement range bull 104 divide 6109 Bqm3
Energy range bull 008 divide 30 MeV
Iodine (UDI-1B)bull scintillation detectors CsI(Tl) (2 pcs for measure-
ment and for background compensation)
SKGAV STACK MONITOR
Particulate noble gas and iodine monitors rack
Measurement range bull 37 divide 37105 Bqm3
Energy range bull 015 divide 30 MeV
Air flow parameters (UPPVM)Measurement range bull air flow velocity 1 divide 20 msbull air temperature 0 divide +80 ordmСbull air humidity 10 divide 95
Radiation monitoring system SPC ldquoDozardquo
28 29
CONFIGURATOR SOFTWAREMaintenance and set-up softwarebull Set-up and verify RMS monitorsbull Control testing adjustment and repair of RMS
monitorsbull Monitors measurement results archive receive
and View bull Communication through RS-232
RMS WORKSTATION ndash OPERATOR CONSOLEOrganization of interaction of the RMS Server and Monitors
Single monitor console includes vandal-proof key-board amp UPS
Reference standard IEC 61559-1 IEC 61559-2
RMS SOFTWAREData acquisition storing and visual representation RMS monitors measurement resultsbull Ethernet IEEE 8023 networkbull Clientserver architecturebull TCPIP protocolbull Oracle based Data Basebull Supremal by means InSat MasterSCADA
Radiation monitoring system SPC ldquoDozardquo
30 31
Delivery setComposition and modification depend on the tasks to be solved using the RM Rack
The rack which is an integral part of RM Rack accommodatesbull Monitors UDA-1AB UDG-1B UDG-03D UDI-1B
UDGB-01Tbull DBG-S11D Wide range gamma area monitor
BDMG-101 High range gamma area monitor UDMN-100 Neutron area monitor BDRG-52R High range gamma area monitor
bull BI-2 Remote display amp alarm unitbull Pump unit BN-01bull Data processing and transmission unit BOP-1Mbull External alarm BAS or BAS-1sbull Equipment of sampling line (flow meters ball
valves filter holder piping solenoid valve)bull Switchboard (intended for switching of all equip-
ment and transfer of data to the upper level via the unified communication channel)
RM RACK RADIATION MONITORING RACK
The radiation monitoring rack (RM Rack) is designed for continuous monitoring of radiation parameters in premises and technological systems at nuclear facil-ities RM Rack can be used as a structural element of the lower-level of RMS at nuclear power plants and other nuclear facilities that involved in obtaining processing use and storage of radioactive materials
FeaturesContinuous automatic monitoring of the alpha- and beta- radioactive aerosol beta-emitting radioactive gases and radioiodine concentrations in the working air and in the air in stacks and others radiation parameters in the facilities
The stand providesbull Primary processing storage and transmission of
measured and related data into the information channel based on the Ethernet IEEE 8023 inter-face (TCPIP protocol)
bull Transfer of required data to the location where the equipment is installed via technological channels based on RS-232 interface
bull Generation of audible and visual warning alarm signals when the preset thresholds are exceeded
bull Display of received data on the LCD
Radiation monitoring system SPC ldquoDozardquo
32 33Reference standards IEC 60860 ANSIANS-83 ISO 7753
Purposebull Detection and recording of criticality accident
(CA) by measuring the absorbed dose rate of gamma-neutron radiation in the premises of monitored object its comparison with a threshold value and generation of audible and visual signals
bull Automatic collection processing storage and display of measurement data and related infor-mation as visual and graphical representation for operators of nuclear safety service
Functions of the systembull Detection and recording of CA events by con-
tinuous measurement of absorbed dose rate of gamma radiation comparison of measured values with preset thresholds generation of signals to activate the alarm
bull Activation of audible visual alarmbull In the event of CA turning on warning signals
ldquoDO NOT ENTERrdquo at illuminated information pan-els placed at the entrances to the controlled area
Featuresbull Data can be transferred to external data commu-
nication channel using RS-485 interface (DiBus data exchange protocol)
bull Automatic self-testing of detection units BR-04D with display of information about the type of fault
bull Possibility for connecting additional a detection and alarm units
bull Ability to function in general regardless of the functioning of components within the agreed scope of nuclear safety tasks
bull Radiation hardness up to 100 Gy
SRKS-01DCRITICALITY ACCIDENT ALARM SYSTEM
Features of softwarebull Collection of information via RS-485 network
displaying it on the PC monitor transmission to remote users archiving and storage
bull Status monitoring and display of values measured by BR-04D and DBG-S11D in locations as per layout of premises
bull Access to archived data with possibility to gener-ate reports for periods determined by operator
bull Maintenance and archiving of a log of dosimetric measurements data and events along with their time stamps
bull Possibility to transfer data to external users via Ethernet network for integrating of CA into higher level systems
Basic complete setLower level bull Control unit with power supplybull BR-04D detection unitsbull BZS-01D audible alarm unitsbull BSS-01D visual alarm unitsbull SIT-01D illuminated warning signsbull PBZ panels for muting audible alarmbull Network communication module
Additional lower layer devicesbull DBG-S11D wide range gamma area monitor
Upper layer bull CDP central display panelbull Service workstation
RS-485
RS-485
RS-4
85
Audible alarm units BZS-01D
Illuminated warning signs SIT-01D
Detection units BR-04D
Network communication
moduleDBG-S11D wide range gamma area monitor
Panels for muting audible alarm
Control unit with power supply
Visual alarm units BSS-01D
RS-485
RS-485
RS-4
85
Audible alarm units BZS-01D
Illuminated warning signs SIT-01D
Detection units BR-04D
Network communication
moduleDBG-S11D wide range gamma area monitor
Panels for muting audible alarm
Control unit with pow-er supply
Visual alarm units BSS-01D
RS-485
RS-4
85
Audible alarm units BZS-01D
Illuminated warning signs SIT-01D
Detection units BR-04D
Network communication
moduleDBG-S11D wide range gamma area monitor
Panels for muting audible alarm
Control unit with power supply
Visual alarm units BSS-01D
RS-485
RS-485
RS-4
85
Audible alarm units BZS-01D
Illuminated warning signs SIT-01D
Detection units BR-04D
Network communication
moduleDBG-S11D wide range gamma area monitor
Panels for muting audible alarm
Control unit with power supply
Visual alarm units BSS-01D
Ethernet
Central display panel Service workstation
RS-485
RS-485
RS-4
85
BZS-01D audible alarm units
SIT-01D illuminated warning signs
BR-04D detection units
Network communication
moduleDBG-S11D wide range gamma area monitor
PBZ panels for muting audible alarm
Control unit with power supply
BSS-01D visual alarm units
Radiation monitoring system SPC ldquoDozardquo
34 35
ldquoBREEZErdquoHIGH-VOLUME AIR SAMPLER
Physical characteristicsbull Measurement range of air flow rate
250 divide 1200 m3hbull Continuous operation time not less than 24 h
Filter materialsbull High-purity glass fiberbull Pure quartz or cellulosebull Filter fabric FPP-15-15
Electrical characteristicsPower supply bull 220380 V 50 Hz
Interfaces bull RS-485bull Ethernetbull GSMGPRS (option)
Environmental characteristicsTemperature range bull minus 40 divide + 40 ordmC
Relative humidity limit at 35 ordmC bull 95
Atmospheric pressure range bull 840 divide 1067 kPa
Versionsbull Standalone unit bull Part of Environmental Radiation Monitoring
System (ERMS)
Type of detection unitsbull Beta block BDZB-100Lbull DBG-S11D wide range gamma area monitorbull Scintillation spectrometric block
The motor of Air Sampler is controlled by an electronic flow sensor that detects changes in the operators pre-set flow rate caused by changes in temperature barometric pressure and pressure drop due to dust loading on filter media It compensates for these changes by adjusting the motor speed to maintain the pre-set flow ratebull Measurement of parameters of ionizing radiation bull Standalone mode of operation or as the part
of Environmental Radiation Monitoring System (ERMS)
Purposebull Environmental Radiation Monitoring System
(ERMS) in the control and buffer areas of the radia-tion and nuclear facilities
Referencesbull Since the year 2000 the system is successfully
operating the ERMSs at 8 Russian nuclear power plants (about 180 monitoring stations)
bull Since the year 2005 the ERMS is operating in the Moscow (about 40 monitoring stations)
bull Since the year 2005 the regional ERMS is under operation in several Russian Federation regions
Basic complete setMonitoring stations bull Data processing and transmission unit BOP-1TA bull Gamma area monitor DBG-S11D
Central data processing station (CDPS)bull Data processing and transmission unit BOP-1TAbull Server
By requestbull Emergency Response and Crisis Management
Centers for enterprisesbull Regional Emergency Response and Crisis Manage-
ment Centersbull rdquoBreezerdquo High-Volume Air Samplerbull Mobile lab with gamma-survey system rdquoGammandash
sensorrdquo
ldquoATLANT-MrdquoENVIRONMENTAL RADIATION MONITORING SYSTEM
Monitoring system for the continuous radiation monitoring of territories and facilities with the data transmission GSMGPRS network
Data transmission bull GSMGPRS
Power supply bull 220 V 50 Hz
Continuous autonomous operation (at 20 ordmC)bull From built-in battery not less than 5 hoursbull From external battery not less than 24 hours
Operation temperature bull Minus 40 divide +50 ordmC
Operation humidity bull Up to 98
Protection bull IP65
Reference standards Nuclear IEC 61017-11991 IEC 61017-21994
36
Radiation Monitoring Equipment
bull Localization of radioactive contaminationsbull Database with dose rate contaminations
spectra measurement date amp time coordi-nates
bull Work as part of mobile laboratory or as part of Environmental Radiation Monitoring System with real-time data transfer
Physical characteristicsDetector bull Scintillation NaI (Tl) GM counters
Measurement rangebull 01 ndash 107 μSvh
Energy range bull 005 ndash 3 MeV
Operation temperature range bull minus 10 divide +50 ordmС
Electrical characteristics bull Power supply 220 V 50 Hz
ldquoGAMMAndashSENSORrdquoGAMMA-SURVEY SYSTEM
SPC ldquoDozardquoRadiation monitoring equipment
38 39
AREA MONITOR ldquoFREGATrdquoArea Monitor ldquoFregatrdquo is designed for building rela-tively simple and inexpensive radiation monitoring systems at such facilities as radionuclide sources storage areas isotope products warehouses nuclear medicine departments PET centers calibration laboratories where sources of ionizing radiation are used etc
Small scale automated radiation monitoring systems built with ldquoFregatrdquo components featuring audible and visual alarms are matched suitable to meet the regulatory radiation safety requirements
Area monitor ldquoFregatrdquo requires virtually no adjust-ment it is simple and convenient for installation and operation
BPI-1D LOCAL DISPLAY UNIT
Display of monitored parameters values received from external measuring devices
Purposebull Processing and display of values of monitored
parameters on information panel bull Comparison of values of monitored parameters
with thresholdsbull Transfer of monitored parametersrsquo values to
networkbull Generation of alarm in case of exceeding of preset
thresholds including external alarm devices
FeaturesTesting the unit and connected devicesbull Visually on the panelbull Using adjustment software when connected to
PC via USB
Automatic self-testing
The panel displays the following informationbull Diagnostic information about the status of con-
nected devicesbull Current date and timebull Values of measured parametersbull Position of measured values with respect to the
thresholds in the form of scales with green yellow and red zones
bull Time history (trend) for each measured value
Physical characteristicsTemperature range bull minus 10 divide + 50 ordmC
Maximum number of connected devicesbull measuring devices 15bull external audible and visual alarm 15
Display diagonal bull 152 cm (6)
Electrical characteristicsbull Interfaces RS-485bull Power supply 220 V 50 Hz 12 divide 24 V
Mechanical characteristicsbull Protection index IP54bull Paint decontaminable
Overall dimensions weightbull 296x248x118 mm 5 kg
DBG-S11D wide range gamma area monitor
UDMN-100 neutron area monitor
Ethernet RS-485
UDKS-100 gamma and X-ray area monitor
BPI-1D Local display unit
BAS-2 ldquoMicrordquo external visual alarm
BZS-2 ldquoMicrordquo external audible alarm
ldquoImpulsrdquo external display unit
Service workstation
Illuminated warning signs
SPC ldquoDozardquoRadiation monitoring equipment
4140
Continuous automatic monitoring of the gamma- X-ray ambient dose equivalent rate
Physical characteristicsbull Detector tissue-equivalent plastic scintillator
Oslash 45times20 mm
Measurement range bull Dose rate measurement range 01 μSvh divide 1 Svh bull Energy range 0015 divide 10 MeV
Mechanical characteristicsbull Protection index IP65bull Paint decontaminable
Overall dimensions weightbull Oslash72times265 mm 15 kg
UDKS-100 GAMMA AND X-RAY AREA MONITOR
UDMN-100 NEUTRON AREA MONITOR
Physical characteristicsbull detector ndash scintillator ZnS(Ag) Li-6
Measurement range bull 01 μSvh divide 01 Svh
Energy range bull 0025 eV divide 100 MeV
Temperature range bull minus 45 divide +50 ordmC
Electrical characteristicsbull Interfaces RS-485
Mechanical characteristicsbull Protection index IP 65bull Paint decontaminable
Overall dimensions weight bull 428times258times347 mm 115 kg
Continuous automatic monitoring of the neutron-radiations ambient dose equivalent ratebull Spherical polyethylene moderator Oslash 239 mm
MEASURING UNITS
DBG-S11D WIDE RANGE GAMMA AREA MONITOR
Continuous automatic monitoring of the gamma- ambient dose equivalent rate
Physical characteristicsbull Detector ndash GM counters
Measurement rangebull DBG-S11D 01 μSvh divide 10 mSvhbull DBG-S11D-01 01 μSvh divide 10 Svhbull DBG-S11D-02 01 μSvh divide 100 Svh
Energy rangebull 005 divide 30 MeV
Temperature range bull minus 40 divide +50 ordmC
Electrical characteristicsbull Interfaces RS-485 USB
Mechanical characteristicsbull Protection index IP 68bull Paint decontaminable
Overall dimensions weightbull DBG-S11D Oslash 68times141 mm 065 kg bull DBG-S11D-01 Oslash 68times179 mm 07 kgbull DBG-S11D-02 Oslash 68times179 mm 07 kg
Versionsbull DBG-S11Dbull DBG-S11D-01bull DBG-S11D-02
Reference standards Nuclear IEC 60846 IEC 60532 EMC IEC 61010 IEC 61000-6-2 Seismic IEC 60980
SPC ldquoDozardquoRadiation monitoring equipment
4342
ALARM UNITS
Generation visual signals of the excess of preset thresholds
Physical characteristicsLength of communication cablebull up to 1200 mbull Alarm Visual alarm green yellow red
Electrical characteristicsbull Power supply +12 V
Mechanical characteristicsbull Protection index IP 23
Overall dimensions weight 160times84times41 mm 02 kg
BAS-2 ldquoMICROrdquo EXTERNAL VISUAL ALARM
Generation audible signals of the excess of preset thresholds
Physical characteristicsLength of communication cablebull up to 1200 mbull Audible alarm 80 divide 100 dB at a distance of 1 m
Electrical characteristicsbull Power supply +12 V
Mechanical characteristicsbull Protection index IP 23
Overall dimensions weight 160times84times41 mm 02 kg
BZS-2 ldquoMICROrdquo EXTERNAL AUDIBLE ALARM
Physical characteristicsLength of communication cablebull up to 1200 m
Electrical characteristicsbull Power supply 220 V 50 Hz
Mechanical characteristicsbull Protection index IP 23
Overall dimensions weight bull 330times110times20 mm 05 kg
Physical characteristicsLength of communication cablebull up to 1200 m
Character height bull ldquoImpuls-910-Rrdquo 100 mmbull ldquoImpuls-915-D4Srdquo 150 mmbull ldquoImpuls-927-D4Srdquo 270 mm
Operating temperature rangebull ldquoImpuls-910-Rrdquo 0 divide +50 degCbull ldquoImpuls-915-D4Srdquo ldquo-727-D4Srdquo minus 40 divide +50 degC
Electrical characteristicsbull Power supply 220 V 50 Hz
Mechanical characteristicsProtection index bull ldquoImpuls-910-R IP 44bull ldquoImpuls-915-D4Srdquo ldquo-727-D4Srdquo IP 65
Overall dimensions weight bull ldquoImpuls-910-Rrdquo 400times160times60 mm 3 kgbull ldquoImpuls-915-D4Srdquo 815times250times80 mm 5 kgbull ldquoImpuls-927-D4Srdquo 1250times330times80 mm 5 kg
ILLUMINATED WARNING SIGNS
ldquoIMPULSrdquo EXTERNAL DISPLAY UNIT
SPC ldquoDozardquoRadiation monitoring equipment
4544
Individual threshold setting for each measurement channel
Continuous area and process monitoring
Collect amp display data from two measurement chan-nels (units with RS-485 or analog pulses)
Audible and visual alarms on exceeding preset thresholds or status of connected devices
Individual threshold setting for each measurement channel
Switching on the external alarm or executive devices when any threshold is exceeded
The wide panel displays the following information bull Values of measured parameters as min-1∙cm-2
s-1∙cm-2 μSvhbull Diagnostic information about the status of con-
nected devicesbull Current date and timebull Position of measured values with respect to the
thresholds in the form of scales with green yellow and red zones
bull Time history (trend) for each measured value
Physical characteristics Measurement range bull Count rate up to 107 CPM (170 kHz)
Operating temperature range bull minus 20 divide +50 ordmC
Electrical characteristics bull Power supply 220 V bull Interfaces USB
Mechanical characteristics bull Protection index IP 65 bull Overall dimensions weight 222times164times73 mm
40 kg
UIM-3D AREA MONITOR COUNT RATE METER
Measurement of alpha radiation flux density
Detector unit BDZA-100 (70 cm2) Measurement range 01 divide 104 min-1∙cm-2
Detector unit BDZA-100B (300 cm2) Measurement range 01 divide 2103 min-1∙cm-2
Measurement of beta radiation flux density
Detector unit BDZB-100 (28 cm2) Measurement range 10 divide 105 min-1∙cm-2
Detector unit BDZB-100L (30 cm2) Measurement range 10 divide 104 min-1∙cm-2
Detector unit BDZB-11D (84 cm2) Measurement range 5 divide 15∙104 min-1∙m-2
OPTIONAL PROBESMeasurement of gamma radiation flux density
Detector units BDEG-03 Measurement range 4 divide 2000 s-1∙cm-2
Detector unit UDKG-100 for operation in the rocks ore liquid media and sludge Measurement range 40 divide 8000 s-1∙cm-2
Measurement of the ambient dose equivalent rate
Detector unit DBG-S11D Measurement range 01 μSvh divide 100 Svh
Measurement of neutron radiation ambient dose equivalent rate
Detector unit BDMN-100 Measurement range 01 μSvh divide 01 Svh
SPC ldquoDozardquoRadiation monitoring equipment
46 47Reference standards Nuclear IEC 61526
Measurement of gamma-radiation personal dose equivalent Hp(10)bull Stand-alone dosimeter or composed of dosimetric
system onebull Audible and visual alarmbull Large memory dose accumulation historiesbull Exclusion of unauthorized intervention in dosim-
etry operation
DKG-05D PERSONAL GAMMA DOSIMETER
Physical characteristicsDetectors bull Silicon
Measurement range bull Dose rate 1 μSvh divide 10 Svhbull Dose 01 μSv divide 15 Sv
Energy range bull 005 divide 30 MeV
Electrical characteristicsbull Power supply rechargeable NiMH battery 1
alcaline battery (type AAA)
Operation timebull Till recharging not less 400 hoursbull With one set batteries not less 1000 hours
Mechanical characteristicsOverall dimensions weight bull 47times26times87 mm (with clip) 70 g
Environmental characteristicsbull IP65bull Temperature range minus 20 divide +45 ordmCbull Humidity up to 98 at 35 ordmCbull Shock vibration and drop resistant
Alarmbull Excess of alarm thresholdsbull Warnings of self-test failure and battery discharge bull Audible alarm 80 dB at 40 cmbull Visual alarm blinking LED
Relative equipmentbull One dosimeter charger ZU-1Mbull Chargestorage cassetes KZU-28KZU-56bull ldquoSmart chargingrdquo feature extends battery life timebull DKG-05D reader US-05bull DKG-05D system reader DVS-01D
Reader-PC interfacebull US-05 USB bull DVS-01D Ethernet
KZU-28
Physical characteristicsDetectors bull Silicon Li-6
Gamma measurement range bull Dose rate 1 μSvh divide 10 Svhbull Dose 01 μSv divide 15 Sv
Gamma energy range bull 005 divide 60 MeV
Neutron measurement range bull Dose rate 1 μSvh divide 2 Svhbull Dose 20 μSv divide 15 Sv
Neutron energy range bull 0025 eV divide 20 MeV
Electrical characteristicsPower supply bull Rechargeable NiMH batterybull Operatiion time till recharging not less 200 hours
Mechanical characteristicsOverall dimensions weight bull 47times26times87 mm (with clip) 70 g
Environmental characteristicsbull IP65bull Temperature range minus 20 divide +40 ordmCbull Humidity up to 75 at 30 ordmCbull Shock vibration and drop resistant
Alarmbull Excess of alarm thresholds bull Warnings of self-test failure and battery discharge bull Audible alarm 80 dB at 40 cmbull Visual alarm blinking LED
Relative equipmentbull One dosimeter charger ZU-1Mbull Chargestorage cassetes KZU-28 KZU-56bull ldquoSmart chargingrdquo feature extends battery life timebull DVS-02D reader UZS-01Sbull DVS-02D system reader DVS-01D
Reader-PC interfacebull UZS-01S USB bull DVS-01D Ethernet
UZS-01DReference standards Nuclear IEC 61526
DVS-02D GAMMA-NEUTRON PERSONAL ELECTRONIC DOSIMETER
Measurement of gamma- and neutron radiations personal dose equivalent Hp(10)bull Stand-alone dosimeter or composed of dosimetric
system onebull Audible and visual alarmbull Large memory dose accumulation historiesbull Exclusion of unauthorized intervention in dosim-
etry operationbull Both albedo thermal neutrons and intermediate
fast neutrons registrationbull Usable in the fields of Pu(Be) Po(Be) Cf and other
neutron sources as well as near nuclear reactors without neutron spectrum estimation
SPC ldquoDozardquoRadiation monitoring equipment
48 49
Dosimeters DVG-03D
DVGI-8D NEW PEN-TYPE PERSONAL IONIZATION CHAMBER DOSIMETERS
Measurement of personal dose equivalent Hp(10) of gamma and X-ray radiationbull Hp(10) of continuous and pulsed gamma and
X-ray radiation bull Electronic reader KSU-1bull Dosimeter DVG-03D with electronic ID bull Personal dose histories in the readerrsquos memorybull Readerrsquos connection with PC for database main-
tenance
Physical characteristicsDetector bull Ionization chamber
Measurement range bull 001 mSv divide 25 mSv
Energy range bull 0015 divide 25 MeV
Temperature range bull Reader KSU-1 +10 divide +50 ordmСbull Dosimeter DVG-03D minus 40 divide +50 ordmС
Electrical characteristicsPower supply bull Reader KSU-1 220 V 50 Hz built-in batteries bull Dosimeter DVG-03D four batteries CR 1025 bull Batteries life 3 yearsbull Readers interfaces RS-232USB 20
Mechanical characteristicsOverall dimensions weightbull Dosimeter DVG-03D Oslash 18times126 mm 005 kgbull Reader KSU-1 235times232times125 mm 28 kg
Reference standards Nuclear IEC 62387-1
DKG-02U ldquoARBITERrdquo WIDE RANGE GAMMA-DOSIMETER
Physical characteristicsDetectors bull GM counters
Measurement rangebull Dose-rate 01 μSvh divide 3 Svhbull Dose 1 μSv divide 100 Sv
Energy range bull 005 divide 3 MeV
Electrical characteristicsbull Power supply 2 alcaline batteries (type AA)bull Batteries life not less 200 hours
Mechanical characteristicsOverall dimensions weight bull 152times82times32 mm 03 kg
Environmental characteristicsbull Temperature range minus 20 divide +50 ordmCbull Humidity up to 90 at +25 ordmCbull Shock vibration and drop resistant
Reference standards Nuclear IEC 60846
Measurement of gamma radiation ambient equiva-lent dose H(10) and dose rate H(10)bull Audible signals (clicks) for radiation condition
estimationbull Analog scale for search modebull Audible and visual alarms of the excess of preset
dose and dose rate thresholds bull Shock-resistant water-proof easy decontamina-
tion casebull 100 measurement results memory with date and
time of measurementbull Indication of total dose accumulated during
exploitation time bull Indication of measurement result statistical
uncertainty
SPC ldquoDozardquoRadiation monitoring equipment
50 51
Physical characteristicsDetectors bull GM counter
Measurement rangebull Dose-rate 01 μSvh divide 3 mSvhbull Dose 1 μSv divide 02 Sv
Energy range bull 005 divide 3 MeV
Temperature range bull Minus 20 divide +50 ordmC
Electrical characteristicsbull Power supply 2 alcaline batteries 15 V (type AA)bull Batteries life not less 200 hours
Mechanical characteristicsOverall dimensions weight bull 122times74times29 mm 025 kg
Reference standards Nuclear IEC 60846
DKG-07D ldquoDROZDrdquoGAMMA-DOSIMETER
Measurement of gamma radiation ambient equiva-lent dose H(10) and dose rate H(10)bull Two independent measurement channels dose
and dose ratebull Audible signals (clicks) for radiation condition
estimationbull Continuous measurement with updating meas-
urement resultbull Measurement result can be obtained with any
desired statistical uncertainty (error)bull Automatic restart when radiation level sharply
changesbull Indication of statistical uncertainty (error) during
measurement process
Continuous measurement with updating measure-ment result
Automatic restart when radiation level sharply changes bull Gamma dose H(10) and dose-rate H(10) meas-
urementbull Beta and gamma contamination surveybull Indication of statistical uncertainty during the
measurementbull Continuous measurement with accuracy increas-
ing with time bull Automatic restart triggered by change of gamma
dose-ratebull Compensation of gamma count rate while meas-
uring beta radiationbull Indication of battery charge levelbull Audible signal of the excess of preset threshold
Physical characteristicsDetectors bull GM counter
Measurement range bull Dose-rate 01 microSvh divide 20 mSvhbull Dose 1 microSv divide 100 Svbull Beta flux density (for Sr-90+Y-90)
10 divide 105 cm-2 min-1
Energy range bull Gamma 005 divide 3 MeVbull Beta 01 divide 3 MeV
Temperature range bull Minus 20 divide +50 ordmC
MKS-15D ldquoSnegirrdquo backside
MKS-15D ldquoSNEGIRrdquoMULTI ndash PURPOSE RADIATION SURVEY METER
Reference standards Nuclear IEC 60846 IEC 60325
Electrical characteristicsbull Power supply 2 alcaline batteries (type AA)bull Battery life not less 400 hours
Mechanical characteristicsOverall dimensions weight bull 124times72times35 mm 035 kg
SPC ldquoDozardquoRadiation monitoring equipment
52 53
Physical characteristicsDetectorbull GM counter
Measurement range bull 01 μSvh divide 20 mSvh
Energy range bull 005 divide 30 MeV
Threshold setting range bull 03 μSvh divide 20 mSvh
Step change of the thresholdbull In the range 03 divide 10 μSvh with the step
001 μSvhbull In the range 10 divide 100 μSvh with the step
01 μSvhbull In the range 100 divide 2000 μSvh with the step
10 μSvh
Electrical characteristicsPower supply bull 220 V 50 Hz bull Relay output
Mechanical characteristicsProtection index bull IP 40
Overall dimensions weight bull 226times120times75 mm 07 kg
Alarmbull Sound alarm 80 divide 100 dBA at distance 1 mbull Visual alarm redbull Connection of the external alarm signaling unit
Reference standards Nuclear IEC 60846 IEC 60532
Continuous automatic monitoring of the ambient dose equivalent rate bull Measurement of gamma dose rate H(10)bull Audible and visual alarm signals for preset
thresholdsbull Switching on the external signaling or executive
devices
SRPS-05D GAMMA MONITOR
Measurement ofbull Gamma and X-ray personal dose equivalent
Hp(10)bull Neutron personal dose equivalent Hp(10)bull Lens dose equivalent Hp(3)bull Skin dose equivalent Hp(007)bull TLD reader day-to-day tests using built-in LEDbull No needs nitrogen for heating
Physical charachteristicsDetectors bull 7LiF Mg Ti (gamma beta)bull 6LiF Mg Ti (neutron)
Gamma and X-ray Hp(10) Measurement range bull 500 μSv divide 10 Sv
Energy range bull 0015 divide 30 MeV
Neutron Hp(10)Measurement range bull 01 mSv divide 100 mSv
Energy range bull 0025 eV divide 10 MeV
Beta and photons Hp(007) Hp(3) Measurement range bull 2 mSv divide 100 Sv
Energy range bull Beta 025 divide 35 MeVbull Photons lt15 keV
Mechanical characteristicsDosimeters overall dimensions weight bull Gamma Hp(10) DTL-2 holder - 62times26times16 mm
16 gbull DTU holder - 42times28times18 mm 8 gbull Lens Hp(3) face skin Hp(007) Oslash 32times16 mm 9 gbull Finger skin Hp(007) 90times20times2 mm 1 gbull Neutron gamma Hp(10) 48times40times20 mm 30 g
Reference standards Nuclear IEC 61066
DTL-2 DTU-2
MKD (A-type) DVNG-M
DOZA-TLD MULTIPURPOSE TLD SYSTEM
SPC ldquoDozardquoRadiation monitoring equipment
54 55
Continuous and pulsed gamma and X-ray dose H(10) and dose-rate measurementbull Alpha beta and gamma contamination surveybull Neutron dose H(10) and dose-rate measurementbull Gamma radiation flux density in boreholes and
liquid media measurement
Electrical characteristicsPower supply bull UIK-05 four C-size batteriesbull UIK-05-01 rechargeable batterybull UIK-06 rechargeable battery
Interfaces bull RS-232bull USB (via adapter)
bull Detector type automatic determination and corre-sponding measurement modes selection
bull Alarm threshold settings ndash for dose dose-rate alpha and beta contaminations
bull ldquoDetectrdquo and ldquoLocaterdquo modes for survey probes
Reference standards Nuclear IEC 60846 IEC 60325 IEC 61005 IEC 62363
Case
UIK-06 control unit165times78times48 mm 03 kg
DKS-96UNIVERSAL RADIATION SURVEY METER
UIK-05 control unit202times86times90 mm 10 kg
BDZA-96
BDZA-96B
BDZA-96M
BDZA-96S
BDZA-96T
EXTERNAL PROBES ALPHAALPHA BDZA-96Detector bull ZnS(Ag) 70 cm2
Measurement range (for Pu-239)bull 01 divide 104 min-1cm-2
Overall dimensions weightbull Oslash 130times240 mm 11 kg
ALPHA BDZA-96BDetector bull ZnS(Ag) 300 сm2
Measurement range (for Pu-239)bull 01 divide 2103 min-1cm-2
Overall dimensions weightbull Oslash 230times290 mm 40 kg
ALPHA BDZA-96MDetector bull ZnS(Ag) 10 сm2
Measurement range (for Pu-239)bull 01 divide 105 min-1cm-2
Overall dimensions weightbull Oslash 65times240 mm 09 kg
ALPHA BDZA-96SDetector bull ZnS(Ag) 30 сm2
Measurement range (for Pu-239)bull 01 divide 5104 min-1cm-2
Overall dimensions weightbull Oslash 90times240 mm 10 kg
ALPHA BDZA-96TDetector bull Silicon 5 сm2
Measurement range (for Pu-239)bull 01 divide 106 min-1cm-2
Overall dimensions weightbull Oslash 50times60 mm 015 kg
SPC ldquoDozardquoRadiation monitoring equipment
56 57
BETA BDZB-96Detector Scintillator 28 сm2
Measurement range (for Sr-90+Y-90)bull 10 divide 105 min-1cm-2
Energy rangebull 03 divide 30 MeV
Overall dimensions weightbull Oslash 90times230 mm 09 kg
BETA BDZB-99Detector bull GM counter 30 сm2
Measurement range (for Sr-90+Y-90)bull 20 divide 104 min-1см-2
Energy rangebull 012 divide 30 MeV
Overall dimensions weightbull Oslash 88times80 mm 04 kgbull Telescopic pole length 07 m
BETA BDZB-96BDetector bull GM counter 80 сm2
Measurement range (for Sr-90+Y-90)bull 3 divide 104 min-1сm-2
Energy rangebull 012 divide 30 MeV
Overall dimensions weightbull 150times200times110 mm 15 kg
BETA BDZB-96Sbull Detector GM counter 15 сm2
Measurement range (for Sr-90+Y-90)bull 10 divide 3104 min-1cm-2
Energy rangebull 012 divide 30 MeV
Overall dimensions weightbull Oslash 65times65 mm 03 kgbull Telescopic pole length 07 m
BDZB-96
BDZB-99
BDZB-96B
BDZB-96S
EXTERNAL PROBES BETA
GAMMA BDKS-96BDetector bull Tissue-equivalent scintillator Oslash 45times20 mm
Measurement rangebull Dose rate H(10) 01 μSvh divide 1 Svhbull Dose H(10) 01 μSv divide 10 Sv
Energy rangebull 0015 divide 10 MeV
Overall dimensions weightbull Oslash 60times250 mm 085 kg
GAMMA AND BETA BDKS-96SDetector bull Double GM counters
Measurement rangebull Gamma dose rate H(10) 01 μSvh divide 1 mSvhbull Gamma dose H(10) 01 μSv divide 10 Svbull Beta 10 divide 3104 min-1cm-2
Energy rangebull Gamma 005 divide 3 MeVbull Beta 012 divide 3 MeV
Overall dimensions weightbull Oslash 80times80 mm 035 kgbull Telescopic pole length 07 m
GAMMA BDMG-96Detector bull GM counters
Measurement rangebull Dose rate H(10) 01 μSvh divide 10 Svhbull Dose H(10) 01 μSv divide 10 Sv
Energy range bull 005 divide 3 MeV
Overall dimensions weightbull 40times250 mm 05 kgbull Telescopic pole length 07 m 4 m (by request)
EXTERNAL PROBES GAMMA
BDKS-96B
BDMG-96
BDKS-96S
SPC ldquoDozardquoRadiation monitoring equipment
58 59
GAMMA-SEARCH BDVG-96Detector bull Scintillator NaI(Tl) Oslash 63times63 mm
Measurement rangebull Flux density measurement range 4 divide 2000 s-1cm-2
bull Dose rate H(10) for Cs-137 01 divide 30 μSvhbull Sensitivity for Cs-137 3000 (pulsess-1)( μSvh-1)
Overall dimensions weightbull Oslash 88times400 mm 20 kgbull Modular pole length 16 m
GAMMA-SEARCH BDPG-96Detector bull Scintillator NaI(Tl) Oslash 25times40 mm
Measurement rangebull Flux density measurement range 10 divide 8000 s-1cm-2
bull Dose rate H(10) for Cs-137 01 divide 100 μSvhbull Sensitivity for Cs-137 500 (pulsess-1)( μSvh-1)
Overall dimensions weightbull 50times190times480 mm 10 kgbull Telescopic pole length 07 m
GAMMA-SEARCH BDPG-96MDetector bull Scintillator NaI(Tl) Oslash 18times30 mm
Measurement rangebull Flux density measurement range 10 divide 24000 s-1cm-2
bull Dose rate H(10) for Cs-137 01 divide 300 μSvhbull Sensitivity for Cs-137 200 (pulsess-1)( μSvh-1)
Overall dimensions weightbull Oslash 35times320 mm 05 kgbull Telescopic pole length 07 or 38 m
EXTERNAL PROBES GAMMA
BDVG-96
BDPG-96M
BDPG-96
EXTERNAL PROBESGAMMA BDKG-96 STAINLESS STEEL CASING FOR GEOLOGIC APPLICATIONS WELL LOGGINGDetector bull Scintillator NaI(Tl) Oslash 18times30 mm
Measurement rangebull Flux density measurement range 10 divide 105 s-1cm-2
bull Dose rate H(10) for Cs-137 5 divide 2104 μRhbull Sensitivity for Cs-137 200 (pulsess-1)( μSvh-1)
Overall dimensions weightbull Oslash 38times535 mm 36 kgbull Cable length 10 divide 1000 m
NEUTRON BDMN-96Detector bull Scintillator with ZnS(Ag)
Measurement rangebull Dose rate H(10) 01 μSvh divide 01 Svhbull Dose H(10) 01 μSv divide 10 Sv
Energy range bull 0025 eV divide 10 MeV
Overall dimensions weightbull Detector Oslash 54times200 mm 08 kgbull Moderator Oslash 245 mm 73 kg
NEUTRON-SEARCH BDKN-96Detector bull He-3 counter in polyethilene moderator
Measurement rangebull Dose rate H(10) for Pu-Be 01 μSvh divide 01 Svhbull Dose H(10) for Pu-Be 01 μSv divide 10 Sv
Energy range bull 0025 eV divide 14 MeV
Overall dimensions weightbull 295times142times100 mm 225 kg
BDKG-96M
BDMN-96
BDKN-96
SPC ldquoDozardquoRadiation monitoring equipment
60 61
bull No gas supply neededbull Clothing control detachable right hand detector bull Alpha detector optional connection bull Numeric and color (red green) indication of
control resultsbull LED sensor of hand-foot positioning for start of
measurementbull Automatic compensation of gamma background
and contamination of detectorbull Audible alarm signals of the excess of preset
thresholdsbull Measurement value indication min-1cm-2 or
Bqсm2
Reference standards Nuclear IEC 61098
RZB-05D HAND-FOOT-CLOTHING MONITOR
Physical characteristicsDetectors bull Gamma beta - GM countersbull Alpha - scintillatior ZnS(Ag)
Detecting nuclidesbull Alpha Pu-239 U-234 U-238bull Beta Sr-90+Y-90 F-18 Cs-137 Co-60 Tс-99 O-15
N-13 Sr-89 C-11 I-131 Na-22 Ru-106+Rh-106 Tl-204
bull Gamma Tc-99m I-123
Efficiencybull Alpha
Pu-239 40 U-234 25U-238 15
bull Beta Sr-90 +Y-90 40
Measurement range bull Alpha 1 divide 103 min-1cm-2 bull Beta 10 divide 103 min-1cm-2
bull Gamma 5103 divide 5106 min-1cm-2
Energy range bull Alpha 30 divide 80 MeV bull Beta 008 divide 35 MeV bull Gamma 005 divide 30 MeV
Operation temperature range bull Minus 10 divide +50 ordmС
Electrical characteristicsbull Power supply 220 V 50 Hz
Mechanical characteristicsOverall dimensions weight bull 740times750times1180 mm 45 kg
Versionsbull Withwithout alpha detectorbull Indication (min-1cm-2 ) or (Bqсm2)bull Detectors overall dimensions smbull Hand 178 х 235bull Foot 185 х 436
Whole body contamination monitor RZBA-04-04Mbull No gas supply neededbull Compensation for background gamma radiation
and contamination of detector unitsbull Individual threshold setting for each measure-
ment channelbull Visible and audible alarms ldquoCONTAMINATIONrdquo and
ldquoCLEANrdquo bull Indication of contaminated body parts on the
panel with image of the bodybull Optional remote alpha-detector
Physical characteristicsDetectors bull Beta - GM counters scintillatorsbull Alpha - scintillatior ZnS(Ag)
Measurement range bull Beta 5 divide 15000 min-1cm-2
bull Alpha 01 divide 10000 min-1cm-2
Energy range bull Beta 015 divide 25 MeV bull Alpha 40 divide 56 MeV
Operation temperature range bull +5 divide +50 ordmС
Electrical characteristicsPower supply bull 220 V 50 Hz
Interfaces bull RS-232bull RS-485
Mechanical characteristicsOverall dimensions weight bull 2650times940times930 mm 310 kg
Versionsbull Withwithout alpha detectorbull Indication (min-1cm-2 ) or (Bqсm2)
Reference standards Nuclear IEC 61098
RZBA-04-04MWHOLE BODY CONTAMINATION MONITOR
SPC ldquoDozardquoRadiation monitoring equipment
62 63
RZA-05DALPHA HAND-MONITOR
bull No gas supply needed bull Numeric and color (red green) indication of
control resultsbull LED sensor of hand- positioning for start of
measurementbull Audible alarm signals of the excess of preset
thresholdsbull Measurement value indication min-1cm-2 or
Bqсm2
Physical characteristicsDetectors alpha - scintillatior ZnS(Ag)
Efficiencybull Pu-239 20 bull U-234 14bull U-238 8
Measurement range bull 05 divide 105 min-1cm-2
Energy range bull 41 divide 90 MeV
Operation temperature range bull minus 10 divide +50 ordmС
Electrical characteristicsPower supply bull 220 V 50 Hz
Mechanical characteristicsOverall dimensions weight no more bull 740times1400times1450 mm 70 kg
Reference standards Nuclear IEC 61098
bull Simultaneous measurement of alphabeta activi-ties in the sample
bull Active shielding anti-coincidence background subtraction using GM counters
bull Lead shielding 30 mm
UMF-2000 LOW LEVEL ALPHA- BETA- COUNTER
Physical characteristicsDetectors bull Silicon specrometric detector 500 or 1000 mm2
Measurement range bull Alpha 001 divide 1000 Bq bull Beta 01 divide 3000 Bq
Energy range bull Alpha 35 divide 80 MeV bull Beta 005 divide 35 MeV
Electrical characteristicsPower supply bull 220 V 50 Hz
Interfaces bull RS-232bull USB
Mechanical characteristicsOverall dimensions weight bull 337times286times190 mm 22 kg
Versionsbull Detector area 500 mm2
bull Detector area 1000 mm2
UMF-2000 Detector area 1000 mm2
UMF-2000 Detector area 500 mm2
SpectraDec software for alpha-spectrometric measurements
SPC ldquoDozardquoRadiation monitoring equipment
64 65
DRK DOSE AREA PRODUCT METER
DRK-1bull Diagnostic reference level (DRL) of patients
determinationbull Suitable for all basic types of x-ray machines
Physical characteristicsDetector bull Plane-parallel ionization chamber
Measurement range bull 1 divide 104 cGycm2
Electrical characteristicsPower supply bull 220 V 50 Hz
DRK-1M-CTbull Measuring of dose length product
Physical characteristicsDetector bull Pencil Ionization Chamber
Measurement rangebull 05 divide 109 microGym
DRK-1Mbull Measuring of air kerma on sectional area of the
X-ray beam productbull Measuring of air kerma rate on area productbull Measuring of air kerma ratebull Measuring of air kerma
Physical characteristicsDetector bull Plane-parallel ionization chamber
Measurement rangebull 01 divide 109 microGym2
bull 06 divide 6104 microGym2cbull 30 divide 9105 microGycbull 30 divide 9991011 microGyReference standard IEC 60580 2003
bull Measurement of strontium-90 in the foodstuffs agricultural products etc
bull Measurement of gross beta activity in samplebull Self tests using built-in LED
ldquoPROGRESS-BETArdquo SCINTILLATION BETA SPECTROMETER
Physical characteristicsDetector bull Plastic scintillator Oslash70x10 mm
Sample bull Plate Oslash70 mmbull Weight up to 15 g
Energy range bull 02 divide 30 MeV
Minimum detectable activity of Sr-90 in a 10 g sample on a standard planchet Bqsamplebull In case of absence of K-40 in the sample 01 Bqbull In case the activity of K-40 till 5 Bqg 05 Bq
Electrical characteristics Interface bull USB
Mechanical characteristicsWeight bull No more 50 kg
Complete setBasic complete setbull Detector unit with plastic scintillator integrated
power supply amplifier ADC bull Lead shielding bull ldquoProgressrdquo software bull Сheck source for energetic calibration (Sr-90-Y-90) bull Planchet Oslash 70 mm (5 items) bull Sample dencification device bull Procedure manual for measurement of radio-
nuclidesrsquo activity using the scintillation beta spec-trometer ldquoProgressrdquo
Optional equipment and servicebull Personal computer and printer bull Calibrations for radionuclides not included in the
main library of radionuclides
Progress-Beta
Reference standards IEC 61562
SPC ldquoDozardquoRadiation monitoring equipment
66 67
bull Measurement of gamma activity in foodstuffs soil samples and others environmental objects
bull Identification of radionuclides in the sample bull Automatic correction for sample density bull Self-tests using built-in LED
ldquoPROGRESS-GAMMArdquoSCINTILLATION GAMMA SPECTROMETER
Physical characteristicsDetector bull NaI (Tl) Oslash63times63 mm
Validated measurement geometries bull Marinelli beakers (1 liter) Petri dishes (Oslash90 mm)
etc
Energy range bull 02 divide 30 MeV
Minimum detectable activity Bqsamplebull Cs-137 3 Bqbull Th-232 7 Bqbull Ra-226 8 Bq bull К-40 40 Bq
Electrical characteristics Interface bull USB
Mechanical characteristicsWeight bull No more 120 kg
Complete setBasic complete setbull Scintillation detector unit with NaI (Tl) detector
with integrated power supply amplifier and ADC bull Lead shielding 50 mm bull ldquoProgressrdquo software bull Сheck source for energy calibration (Cs-137 +
K-40)bull Marinelli beakers - 1 liter (5 items) bull Petri dishes Oslash 90 mm (5 items) bull Procedure manual for measurement of activity
of radionuclides using the scintillation gamma spectrometer ldquoProgressrdquo
Optional equipment and servicebull Kit for radon measurements including calibration
of ldquoIC-63rdquo geometry for counting the charcoal samples
bull Personal computer and printer bull Calibrations for user defined geometries bull Calibrations for radionuclides not included in the
main library of radionuclides
Progress-Gamma
Reference standards IEC 61563
ldquoPROGRESS-G(P)rdquoPORTABLE SCINTILLATION GAMMA SPECTROMETERbull Field measurements of gamma activity in environ-
mental objects without sampling (4π geometry)bull Laboratory measurement of gamma activity in
foodstuffs soil samples and others environmental objects
bull Identification of radionuclides in the sample bull Automatic correction for sample densitybull Tests using built-in LED
Physical charachteristicsDetector bull NaI (Tl) Oslash45times50 mmbull Lead shielding 20 mm
Validated measurement geometries bull Marinelli beakers (05 liter) Petri dishes (Oslash90 mm)
etc
Energy range bull 02 divide 30 MeV
Minimum detectable activity in 05-litre Marinelli beaker bull Cs-13710 Bqkgbull К-40100 Bqkgbull Ra-22618 Bqkg bull Th-23216 Bqkg
Minimum detectable activity in 30 min (4π geometry) bull Cs-137 2 Bqkgbull К-40 30 Bqkgbull Ra-226 4 Bqkg bull Th-232 3 Bqkg
Electrical characteristicsPower supply bull Rechargeable batterybull 220 V 50 Hz
Interface bull USB RS-232
Weight bull No more than 60 kg
Complete setBasic complete setbull Scinttillation detector unit with NaI(Tl) bull ldquoProgressrdquo softwarebull Сontrol unit ldquoSputnikrdquo for aquisition and analisys
of spectra with built-in memory for spectral databull Casebull Lead shielding (2 cm) for laboratory usebull 05-litre Marinelli beakers ndash 5 itemsbull Na-22 check sourcebull Power adapter BPS-01bull Operation manualbull Procedure manual for measurement of activity
of radionuclides using the scintillation gamma spectrometer ldquoProgressrdquo
Optional equipment and servicebull Kit for radon measurements with charcoalbull Built-in dose rate meterbull Additional memory (RAM) for storage of 64
spectrabull Additional power adapterbull Notebook and printer
Progress-Gamma
Reference standards IEC 61563
SPC ldquoDozardquoRadiation monitoring equipment
68 69
Physical characteristicsDetectorbull Scintillation detector ZnS (Oslash 60 mm)
Samplebull Thin sample - diameter up to 70 mm bull Preparation technique - electro-depositionbull Thick sample - diameter 70 mm weight
200300 mg bull Preparation technique - application of powders
(prepared by radiochemical concentration by water evaporation or by pounding of mineral samples) onto a planchet with the help of spirit
Energy rangebull 15 divide 8 MeV
Minimum detectable activitybull Thin samples no more than 910-3 Bqsamplebull Thick samples no more than 180 Bqkg
Mechanical characteristicsOverall dimensions weightbull 195times120times210 mm 34 kg
Complete setBasic complete setbull Alpha radiometer ldquoProgress-ARrdquobull Check source (uranium isotopes)
Set of accessoriesbull Procedure manual for measurements of radi-
oactivity using scintillation alpha radiometer ldquoProgress-ARrdquo
bull ldquoProgressrdquo software
ldquoProgress-ARrdquo
bull Measurement of gross activity of alpha emitting radionuclides in thin samples
bull Measurement of gross activity of alpha emitting radionuclides in thick samples
bull Measurement of activity deposited on aerosol filters
ldquoPROGRESS-ARrdquoALPHA RADIOMETER
Several fixed positions of the detector enable to perform measurements in various geometries and to estimate the content ofbull Cs-137 in the whole bodybull I-131 in thyroidbull Co-60 Cs-137 Mn-54 Cr-51 in lungsbull Database for storage of measurement data and
resultsbull Uncertainty calculations based on measurement
databull Self tests using built-in LED
ldquoPROGRESSrdquo WHOLE BODY COUNTER
Physical characteristicsDetectorbull scintillation detector NaI (Tl) Oslash63times63 mm
Energy rangebull 02 divide 28 MeV
Minimum detectable activitybull By Cs-137 in the whole body - 1200 Bqbull By I-131 in thyroid - 100 Bqbull By Co-60 Cs-137 Mn-54 Cr-51 in lungs - 200 Bq
Mechanical characteristicsWeight bull No more than 120 kg
Complete setBasic complete setbull Collimator with rotator and holderbull Detector with incorporated ADCbull Patient chair and table for collimatorbull Check source Na-22bull Procedure manual for lifetime measurement of
gamma-emitting radionuclidesrsquo activity in human body using the gamma-spectrometer of human radiation ldquoProgressrdquo
bull laquoProgressraquo software
Optional equipment and servicebull Program of internal radiation committed internal
radiation effective dose calculation by the stand-ard model
bull Background phantombull Personal computer and printer
Collimator with rotator and holder
SPC ldquoDozardquoRadiation monitoring equipment
70 71
bull Categorization of wastes for the purpose of fur-ther processing including wastes with unknown radionuclide composition
bull Measurements during the incoming waste inspec-tion (accepting for storage disposal)
bull Certification of unconditioned and conditioned wastes in closed containers without opening them (at nuclear plants or at facilities providing collection storage transportation conditioning processing temporal storage and final disposal of radioactive waste)
bull Activity measurement of extended objects in situ without opening the equipment
bull Activity measurement of extended objects after opening (for example assessment of tubes used for oil transportation)
MKG-01D ldquoSADOVNIKrdquoSPECTROMETRY SYSTEM
Physical charachteristicsDetectorbull Detector unit GEM (GMX) with HPGe detector and
multi-positioning cryostat CFG-PMOD4-7 with 7 litre Dewar
bull Dose rate probe BDMG-200
Energy range bull With GEM detector 004 divide 30 MeVbull With GMX detector 0005 divide 15 MeVbull Dose rate probe BDMG-200 ndash 005 divide 30 MeV
Measurement rangebull 110-7 divide 10 Svhbull Relative efficiency of detection (in photopeak) at
13325 MeV (Co-60) 10 divide 150
Electrical characteristicsPower supplybull 220 V 50 Hz
Interfacebull USB
Complete setBasic complete setbull Spectrometric detector unit GEM (GMX) with
HPGe detector and multi-positioning cryostat with 7 litre Dewar
bull Portable digital multichannel analyzer DigiDARTbull Dose rate probe BDMG-200bull Autonomous power supply unit with built-in
batterybull Industrial computer keyboardbull Laser range-finderbull Thermographic printerbull Web-camerabull Device equipped with stepper motor for position-
ing of the spectrometric detectorbull Calibration device with reference sources
(Am-241 Co-60 Ba-133 Eu-152) for energy calibration
bull Removable collimators with end capbull Measurement proceduresbull ldquoClasterrdquo software
bull Measurement of gross alpha activity of alpha-emitting radionuclides
bull Measurement of alpha-emitting radionuclides activity in thin-layer samples meeting alpha-spectrometry requirements
Physical characteristicsDetectorbull Silicon ion-implanted 450 mm2
bull Easy to decontaminate thin windowbull dead layer less than 015 μmbull Background count rate in the range 3 divide 9 MeVbull No more than 09 h-1cm-2 for 450 mm2 detector
Energy rangebull 2 divide 9 MeVbull Lower limit of measurement range (minimum
detectable activity) 01 Bqbull Background count rate no more than 100 counts
in 24 hours
Electrical characteristics Power supplybull 220 V 50 Hz
Interfacebull USB
Complete setBasic complete setbull Detector unit with vacuum measuring chamber
and vacuum control systembull Low noise vacuum pump (type 2FY-05B or
equivalent)bull Check sourcebull ldquoProgressrdquo softwarebull Vacuum tube
MKS-01A ldquoMULTIRAD-ASrdquoALPHA SPECTROMETER
SPC ldquoDozardquoRadiation monitoring equipment
72 73
UCRV-2AIRFLOW MONITOR
bull Monitor of the air flow through filter of centralized multichannel sampling system
bull Radiation monitoring system (RMS) integration for internal exposures determination
bull Volume and flow rate measurements of the air that have passed through a analytical filter
bull Bar-code for filter identificationbull Operation as either standalone unit or as a part of
the RMS
Physical characteristicsMeasurement range of air volume bull 001 divide 9999 m3
Operation temperature range bull minus 20 divide +50 ordmС
Electrical characteristicsPower supply bull 220 V 50 Hz
Interface bull RS-485
PVP-06PORTABLE AIR SAMPLER
Air Sampler PVP-06 is indispensable for monitoring the radiation situation where the concentration of radioactive aerosols in the air does not require a sta-tionary sampling equipment Sampling head PVP-06 provides easy change of filters and cartridges
Purposebull To monitor the concentration of radioactive aero-
sols in the air sites
Controlled aerosolsbull Alpha- and beta-active aerosolsbull Daughter products of decay of radon and thoronbull Iodine isotopes
Physical characteristicsTypes of filtersbull Aerosol AFA-RSP-20bull Iodine AFA SI-20
Flow rate bull 33∙10-4 ndash 233∙10-4 m3s (20 divide 140 l min)
Electrical characteristicsPower supply bull 220 V50 Hzbull The vehicle power supply 108 divide 145 Vbull Internal battery
Minimal working time on internal battery to recharge bull 8 hours
Power consumption (at a flow rate of 100 lmin) bull 40 VA
Environment characteristicsOperating temperature bull minus 10 divide +40 deg C
Maximum humidity bull 90
Pressure bull 860 to 1060 hPA
Noise generated by the pump bull lt 55 dBA at 1 m
Mechanical characteristicsDimensions weight bull 241 times 108 times 160 mm 28 kg
Case material bull Plastic
Complete setbull Air sampler PVP-06bull AC power adapterbull Filters AFA-RSP-20 - 100 pcsbull Packaging for filters - 40 pcsbull Casebull Operation manualbull Calibration certificate
Optional equimpient bull Kit for sampling sorption columns of activated
carbon Ř head of sorption columns with protective
covers Ř activated charcoal SKT-3 - 1 pkg (02 L) Ř charocoal samples SC-13 - 8 pcs
bull Car charger bull Tipod bull Shoulder strapbull Calibration stand bull Filters AFA SI-20 - 100 pcs
Consumablesbull Aerosol filters AFA RSP-20bull Iodine filters AFA SI-20
SPC ldquoDozardquoRadiation monitoring equipment
74 75
Calibration of gamma dose and dose rate meters
Calibration ofbull Ambient equivalent dose H(10) meters (Sv Svh)bull Personal equivalent dose Hp(10) meters (Sv Svh)bull Exposure dose X meters (R Rh)bull Two sources in irradiator bull Select source and collimator opening using
tumbler
UPG-P DESKTOP GAMMA BEAM IRRADIATOR
Physical characteristicsRange of reproduced dose rate bull 05 μSvh divide 10 mSvh (50 μRh divide 100 mRh)
Sources activities bull 6times106 6times108 Bq (02 20 mCi) Cs-137
Overall dimensions bull 1250times400times300 mm
Irradiator weight bull Not more than 37 kg
Calibration bench weight bull Not more than 15 kg
Reference standards IEC 60846 IEC 61526
Physical characteristicsDetectorbull Silicon
Measurement range EEC measurement bull Measurement range of radon EEC
10 divide 10bull106 Bqbullm-3
bull Measurement range of thoron EEC 05 divide 10bull104 Bqbullm-3
bull Air flow through the filter 100plusmn05 lmin
Concentration measurementbull Measurement range of radon-222 concentration
in air 10 divide 20bull106 cpsbull Measurement range of 216Po(ThA)
1bull10-3 divide 1bull102 cpsbull Air sampler flow rate
10plusmn02 lminbull Measurement range of radon-222 concentration
in water samples 6 divide 800 Bqbullkg-1
bull Measurement range of radon-222 flux from soil surface 20 divide 103 mBqsbullm2
bull Measurement range of radon-222 concentration with preliminary sampling of air using air sam-plers 20 divide 107 Bqbullm-3
bull Measurement range of radon-222 concentration in samples of soil air 103 divide 106 Bqbullm-3
Operation temperature range bull 1 divide 35 ordmC
Electrical characteristicsPower supply bull 80 VA
Mechanical characteristicsOverall dimensions weight bull 220times200times165 mm 36 kg
ldquoALPHARAD PLUSrdquoRADON THORON amp THEIR PROGENY MONITORbull Measurement of radon and thoron concentration
and effective equivalent concentration (EEC)bull In the airbull In the indoor air of residential public and industri-
al buildings and structuresbull Measurement of radon in drinking water sourcesbull Measurements of radon flux from the soil surface
at land plots allocated for construction of houses public buildings and industrial facilities
bull Measurements of radon concentration in soil air
Reference standards IEC 61577
SPC ldquoDozardquoRadiation monitoring equipment
76 77
UKPN-2M-D NEUTRON BEAM IRRADIATOR
Reference standards IEC 61005 61322
Calibration of neutron dose and dose rate meters
Calibration ofbull Ambient equivalent dose H(10) meters (Sv Svh)bull Personal equivalent dose Hp(10) meters (Sv Svh)bull Flux density of neutrons (cm-2∙s-1)bull Transfer container for temporary storage of
sources bull Red light signal of source working position
Physical carachteristicsRange of reproduced dose ratebull 20 divide 800 μSvh
Range of reproduced flux densitiesbull 10 divide 400 cm-2∙s-1
Type of a source in use bull Pu-Be
Activity of a source in usebull 24х1011 Bq (with density of 107 s-1)
Overall dimensions weight no morebull 3000x750x2000 mm 300 kg
Required room dimensionsbull not less than 7x3x3 m
Electrical characteristicsPower supply bull 220 V 50 Hz
Calibration of gamma dose and dose rate meters
Calibration ofbull Ambient equivalent dose H(10) meters (Sv Svh)bull Personal equivalent dose Hp(10) meters (Sv Svh)bull Exposure dose X meters (R Rh)bull Four sources in irradiator bull Select source and move to working position
return to storage position using special rodbull Transfer container for temporary storage of
sources bull Red light signal of source working position
UPGD-2M-DGAMMA BEAM IRRADIATOR
Physical characteristicsRange of reproduced dose rate bull 05 μSvh divide 50 mSvh (50 μRh divide 5 Rh)
Maximum activity of source bull 2times1011 Bq (50 Ci) Cs-137
Overall dimensionsbull Irradiator 800times500times500 mmbull Guide rails length 30 mbull Height 16 mbull Weight not more than 700 kgbull Required room dimensions not less than 7x3x3 m
Electrical characteristicsPower supply bull 220 V 50 Hz
UPGD-2M-D
Reference standards IEC 60846 IEC 61526 IEC 61066
SPC ldquoDozardquo
78 79
Contents
MEASURING UNITS
DBG-S11D wide range gamma area monitor 40
UDKS-100 gamma and X-ray area monitor 41
UDMN-100 neutron area monitor 41
ALARM UNITS
BAS-2 ldquoMICROrdquo external visual alarm 42
BZS-2 ldquoMicrordquo external audible alarm 42
Illuminated warning signs 43
ldquoImpulsrdquo external display unit 43
UIM-3D area monitor count rate meter 44
DKG-05D personal gamma dosimeter 46
DVS-02D gamma-neutron personal electronic dosimeter 47
DVGI-8D new pen-type personal ionization chamber dosimeters 48
DKG-02U ldquoARBITERrdquo wide range gamma-dosimeter 49
DKG-07D ldquoDROZDrdquo gamma-dosimeter 50
MKS-15D ldquoSNEGIRrdquo multi ndash purpose radiation survey meter 51
SRPS-05D gamma monitor 52
DOZA-TLD multipurpose TLD system 53
DKS-96 universal radiation survey meter 54
EXTERNAL PROBES ALPHA
Alpha BDZA-96 55
Alpha BDZA-96B 55
Alpha BDZA-96M 55
Alpha BDZA-96S 55
Alpha BDZA-96T 55
EXTERNAL PROBES BETA
Beta BDZB-96 56
Beta BDZB-99 56
Beta BDZB-96B 56
Beta BDZB-96S 56
EXTERNAL PROBES GAMMA
Gamma BDKS-96B 57
Gamma and beta BDKS-96S 57
Gamma BDMG-96 57
EXTERNAL PROBES GAMMA
Gamma-search BDVG-96 58
Gamma-search BDPG-96 58
ContentsRadiation monitoring systemldquoPELIKANrdquo Radiation monitoring system (RMS) 6
BDMG-101 high range gamma area monitor 10
DBG-S11D wide range gamma area monitor 11
BDRG-52 high range gamma area monitor for accident and post-accident conditions 12
UDGP-01 Liquid technological environments monitor 13
UDMN-100 neutron area monitor 14
UDKG-100 Wel Liquid gamma monitor 14
BOP-1M data processing and transmission unit 15
UDA-1AB particulate monitor 16
UDG-1B noble gas monitor 17
UDG-03D noble gas monitor 18
UDI-1B iodine monitor 19
UDGB-01 noble gasesH-3C-14 monitor 20
UDGP-01 steam generator leakage monitor 21
UPPVM air flow parameters monitor 22
ldquoIMPULSrdquo external display unit 23
BI-2 remote display amp alarm unit 24
BASBAS-1s external alarm 25
SKGAV stack monitor 26
RMS software 28
RMS workstation ndash operator console 29
Configurator software 29
RM RACK radiation monitoring rack 30
SRKS-01D criticality accident alarm system 32
ldquoATLANT-Mrdquo environmental radiation monitoring system 34
ldquoBREEZErdquo high-volume air sampler 35
ldquoGAMMA-SENSORrdquo gamma-survey system 36
Radiation monitoring equipmentAREA MONITOR ldquoFREGATrdquo 38
BPI-1D local display unit 39
80
Gamma-search BDPG-96M 58
Gamma BDKG-96 stainless steel casing for geologic applications well logging 59
EXTERNAL PROBES NEUTRON
Neutron BDMN-96 59
Neutron-search BDKN-96 59
RZB-05D Hand-foot-clothing monitor 60
RZBA-04-04M whole body contamination monitor 61
RZA-05D alpha hand-monitor 62
UMF-2000 low level alpha- beta- counter 63
DRK dose area product meter 64
ldquoPROGRESS-BETArdquo scintillation beta spectrometer 65
ldquoPROGRESS-GAMMArdquo scintillation gamma spectrometer 66
ldquoPROGRESS-G(P)rdquo portable scintillation gamma spectrometer 67
ldquoPROGRESS-ARrdquo alpha radiometer 68
ldquoPROGRESSrdquo whole body counter 69
MKG-01D ldquoSADOVNIKrdquo spectrometry system 70
MKS-01A ldquoMULTIRAD-ASrdquo alpha spectrometer 71
UCRV-2 airflow monitor 72
PVP-06 portable air sampler 73
ldquoALPHARAD PLUSrdquo radon thoron amp their progeny monitor 74
UPG-P desktop gamma beam irradiator 75
UPGD-2M-D gamma beam irradiator 76
UKPN-2M-D neutron beam irradiator 77
Radiation monitoring system SPC ldquoDozardquo
8 9
SKGAV Stack monitor
UPPVM Air flow parameters monitor
RM Rack
UDG-1B Noble gas monitor
UDGB-01Noble gasesH-3C-14
monitor
UDA-1AB Particulate monitor
UDI-1BIodine monitor
UDGP-01 Steam generator leakage
monitor
RMSworkstation
Ethernet switch
Ethe
rnet
RS
-485
RMS workstationServer
DBG-S11D Wide range gamma area monitor
BDMG-101 High range gamma area monitor
UDMN-100 Neutron area monitor
BDRG-52 High range gamma area monitor
BASBAS-1s External alarm
BOP-1M Data processing and
transmission unit
RADIATION MONITORING SYSTEM
Ethe
rnet
RS
-485
BI-2 Remote display amp alarm unit
ldquoImpulsrdquoExternal Display Unit
UDKG-100 Wel Liquid gamma monitor
Ethernet RS-485 Ethernet RS-485
UDG-03D Noble gas monitor
UDGP-01 Liquidtechnological environment monitor
Radiation monitoring system SPC ldquoDozardquo
10 11
bull Continuous automatic monitoring of the ambient dose equivalent rate
bull Нigh temperature range (up to 120 degC)
BDMG-101 HIGH RANGE GAMMA AREA MONITOR
Physical characteristicsbull detector ndash ionization chambers
Measurement rangebull MIC-1 5∙10-5 divide 200 Svhbull MIC-2 5∙10-4 divide 1000 Svhbull MIC-3 1∙10-5 divide 100 Gyhbull MIC-4 5∙10-3 divide 10000 Gyh
Energy rangebull 005 divide 30 MeV
temperature rangebull ionization chamber module MIC-1
minus 30 divide +120 degCbull electrometric module MIC-2 MIC-3 MIC-4 ME
minus 30 divide +60 degC
Electrical characteristicsbull interfaces RS-485bull cable length between MIC and ME up to 30 m
Mechanical characteristicsbull Protection index IP 65
Overall dimensions weightbull ME Oslash105times293 mm 23 kgbull MIC-1 Oslash85times206 mm 12 kgbull MIC-2 Oslash45times156 mm 03 kgbull MIC-3 Oslash136times226 mm 09 kgbull MIC-4 Oslash35times92 mm 02 kg
BOP-1M
Reference standards Nuclear IEC 60846 IEC 60532
DBG-S11D WIDE RANGE GAMMA AREA MONITOR
Continuous automatic monitoring of the ambient dose equivalent rate
Physical characteristicsbull Detector ndash GM counters
Measurement rangebull DBG-S11D 01 μSvh divide 10 mSvhbull DBG-S11D-01 01 μSvh divide 10 Svhbull DBG-S11D-02 01 μSvh divide 100 Svh
Energy rangebull 005 divide 30 MeV
Temperature range bull minus 40 divide +50 ordmC
Electrical characteristicsbull Interfaces RS-485 USB
Mechanical characteristicsbull Protection index IP 68bull Paint decontaminable
Overall dimensions weightbull DBG-S11D Oslash 68times141 mm 065 kg bull DBG-S11D-01 Oslash 68times179 mm 07 kgbull DBG-S11D-02 Oslash 68times179 mm 07 kg
Versionsbull DBG-S11Dbull DBG-S11D-01bull DBG-S11D-02
BOP-1M
Reference standards Nuclear IEC 60532
Versionsbull stainless steel 100 cm2 ionization chamber
module (MIC-1) and electrometric module (ME)bull stainless steel 20 cm2 ionization chamber module
(MIC-2) and electrometric module (ME)bull duralumin 500 cm2 ionization chamber module
(MIC-3) and electrometric module (ME)bull titanium 2 cm2 ionization chamber module
(MIC-4) and electrometric module (ME)
Radiation monitoring system SPC ldquoDozardquo
12 13Reference standards EMC IEC 61010 IEC 61000-6-2 Seismic IEC 60980
bull Continuous automatic monitoring of the ab-sorbed dose rate
bull Monitoring inside containmentbull Delivery assembled detector and communication
linebull Communication line include inter wall protective
tubebull Hermetic communication line filled dry nitrogen
Physical characteristicsbull detector - stainless steel ionization chamber
Measurement range bull 10-3 divide 105 Gyh
Energy range bull 006 divide 30 MeV
Temperature range bull detector
0 divide 207 ordmC continuous
250 ordmC during 1 hour bull electrometric module 0 divide +60 ordmC
Detector operating pressure bull 07 МPa
Electrical characteristicsbull Interfaces RS-485bull detector-electrometric module cable length up
to 70 m
BDRG-52 HIGH RANGE GAMMA AREA MONITOR FOR ACCIDENT AND POST-ACCIDENT CONDITIONS
Ionization chamber
Mechanical characteristicsProtection index bull detector - IP 65bull electrometric module - IP 23bull Paint stainless steel
Overall dimensions weight bull detecting unit Oslash50х220 mm 3 kgbull inter wall protective tube Oslash 159 length (by order)
1200 ndash 1600 mm 60 kgbull electrometric module 420x420x120 mm 8 kg
Reference standards Nuclear IEC 60951 EMC IEC 61010 IEC 61000-6-2 Seismic IEC 60980
Continuous monitoring of technological environ-ments liquid couples sludges etc bull On line gamma spectrometry
Physical characteristicsbull Detector ndash scintillator CsI NaI
Measurement range bull Gamma-activity 10bull104 divide 20bull108 Bqm3
Energy range bull gamma 005 divide 15 MeV
Temperature range bull minus 10 divide +80 ordmС
UDGP-01 LIQUID TECHNOLOGICAL ENVIRONMENTS MONITOR
Electrical characteristicsbull Interfaces RS-232 RS-485 Ethernetbull programmable relay output (SPDT relay)
Mechanical characteristicsbull Protection index IP 65bull Paint decontaminable
Overall dimensions weight bull Detector unit
CsIOslash 60x360 mm17 kg NaIOslash 35x750 mm26 kg
bull Data processing and transmission unit BOP-1sp 280x220x114mm 43 kg
Alarmbull Sound alarm 80 divide 100 dBA at distance 1 mbull Visual alarm green yellow redbull Connection of the external alarm unit of ldquoBASrdquo
type
Radiation monitoring system SPC ldquoDozardquo
14 15
BOP-1M DATA PROCESSING AND TRANSMISSION UNIT
bull Processing of data incoming from detecting blocks UDMN-100 DBG-S11D UDKG-100 BDMG-101 BDRG-52
bull Data transmission to the network bull Data transmission to the mobile computer bull Storage of thresholds values and parameters of
detecting blocksbull Power supply and diagnostics of detecting blocks bull Generation of the alarm signals of the excess of
preset thresholdsbull Data backup in the non-volatile memory
Physical characteristicsbull Quantity of joined detecting blocks and alarm
units ndash up to 20bull Temperature range minus 40 divide +50 ordmC
Electrical characteristicsbull Power supply 85 divide 260 V 47 divide 440 Hzbull Interfaces RS-232 RS-485 Ethernet bull programmable relay output (SPDT relay)
Mechanical characteristicsbull Protection index IP 65 bull Paint decontaminable
Overall dimensions weightbull 298times220times114 mm 5 kg
Reference standards EMC IEC 61010 IEC 61000-6-2 Seismic IEC 60980
Continuous automatic monitoring of the neutron-radiations ambient dose equivalent ratebull Spherical polyethylene moderator Oslash 239 mm
UDMN-100 NEUTRON AREA MONITOR
Physical characteristicsbull detector ndash scintillator ZnS(Ag) Li-6
Measurement range bull 01 μSvh divide 01 Svh
Energy range bull 0025 eV divide 100 MeV
Temperature range bull minus 45 divide +50 ordmC
Electrical characteristicsbull Interfaces RS-485
Reference standards Nuclear IEC 61005 IEC 61322 EMC IEC 61010 IEC 61000-6-2 Seismic IEC 60980
UDKG-100WEL LIQUID GAMMA MONITOR
Mechanical characteristicsbull Protection index IP 65bull Paint decontaminable
Overall dimensions weight bull 428times258times347 mm 115 kg
Continuous automatic monitoring of the gamma radiation flux Operation in the rocks ore liquid media and sludge
Physical characteristics bull detector ndash NaI (Tl) Oslash 18x30 mm
Measurement range bull 40 divide 8104 s-1cm-2
Energy range bull 01divide 30 MeV
Temperature rangebull minus 40 divide +50 degC
Electrical characteristics bull Interfaces RS-485
Mechanical characteristics bull Protection index
Ř BDKG-100 IP 68 Ř Interface block BS-16 IP 65
bull Paint stainless steel bull Overall dimensions weight
Ř Detector unit BDKG-100 Oslash 38times530 mm 3 kg Ř Interface block BS-16 176times80times64 07 kg
Radiation monitoring system SPC ldquoDozardquo
16 17
UDG-1B NOBLE GAS MONITOR
Continuous automatic monitoring of the beta-emit-ting radioactive gases concentration in the working air and in the air in ventilation ducts and stacksbull Gamma background compensation bull Audible and visual alarm signals of the excess of
preset thresholds bull Periodic calibration by means of standard beta-
source
Physical characteristicsbull Silicon detectors (2 pcs for measurement and for
background compensation)bull Air flow rate 10 divide 100 lminbull Operation temperature range minus 10 divide +50 ordmС
Measurement range bull 104 divide 6109 Bqm3
Energy range bull 008 divide 30 MeV
Electrical characteristicsbull Power supply 85 divide 260 V 47 divide 440 Hzbull Interfaces RS-232 2timesRS-485 Ethernetbull programmable relay output (SPDT relay)bull Analog output 4-20 mA (optional)
Mechanical characteristicsbull Protection index IP 65bull Paint decontaminable
Overall dimensions weight bull Stationary version 395times240times304 mm 295 kgbull Mobile version with pump unit BN-1
395times468times950 mm 543 kg
Alarmbull Sound alarm 80 divide 100 dBA at distance 1 mbull Visual alarm green yellow red
Mobile version with pump unit BN-1
Stationary version
Reference standards Nuclear IEC 60761 IEC 62302 EMC IEC 61010 IEC 61000-6-2 Seismic IEC 60980
bull Connection of the external alarm unit ldquoBASrdquo type
Versionsbull Stationary versionbull Stationary version with pump unit BN-1bull Mobile version with pump unit BN-1
UDA-1AB PARTICULATE MONITOR
Stationary version
Continuous automatic monitoring of the alpha- and beta- radioactive aerosol concentration in the work-ing air and in the air in ventilation ducts and stacksbull Radon toron progenies and gamma background
compensation bull On line alpha spectrometrybull Audible and visual alarm signals of the excess of
preset thresholds bull Control of electromagnetic valves when operating
with the external air sampling linebull Control of pump unit bull Periodic calibration by means of standard beta-
and alpha-sources
Physical characteristicsbull Silicon specrometric detectors (2 pcs for measure-
ment and for background compensation)bull Filter tape types LFAS FSLWbull Tape consumption (when continuous operation)
10 m50 daysbull Air flow rate 10 divide 100 lmin bull Operation temperature range minus 10 divide +50 ordmС
Measurement range bull Alpha 10-2 divide 2105 Bqm3 bull Beta 10-1 divide 106 Bqm3
Energy range bull Alpha 30 divide 90 MeV bull Beta 005 divide 30 MeV
Electrical characteristicsbull Power supply 85 divide 260 V 47 divide 440 Hzbull Interfaces RS-232 2timesRS-485 Ethernet bull Programmable relay output (SPDT relay)bull Analog output 4-20 mA (optional)
Mechanical characteristicsbull Protection index IP 65bull Paint decontaminable
Overall dimensions weight bull Stationary version 389times260times304 mm 156 kg bull Mobile version with pump unit BN-1
389times468times950 mm 384 kg
Alarmbull Sound alarm 80 divide 100 dBA at distance 1 mbull Visual alarm green yellow redbull Connection of the external alarm unit ldquoBASrdquo type
Versionsbull Stationary versionbull Stationary version with pump unit BN-1bull Mobile version with pump unit BN-1
Reference standards Nuclear IEC 60761 IEC 61172 EMC IEC 61010 IEC 61000-6-2 Seismic IEC 60980
Mobile version with pump unit BN-1
Radiation monitoring system SPC ldquoDozardquo
18 19
Physical characteristicsbull Scintillation detectors CsI(Tl) (2 pcs for measure-
ment and for background compensation)bull Cartridge activated charcoal
Measurement range bull 37 divide 37106 Bqm3
Energy range bull 006 divide 30 MeVbull Air flow rate 20 divide 40 lminbull Operation temperature range minus 10 divide +50 ordmС
Electrical characteristicsbull Power supply 85 divide 260 V 47 divide 440 Hzbull Interfaces RS-232 2timesRS-485 Ethernetbull Programmable relay output (SPDT relay)bull Analog output 4-20 mA (optional)
Mechanical characteristicsbull Protection index IP 65bull Paint decontaminable
Overall dimensions weight bull Stationary version 448times323times479 mm 35 kgbull Mobile version with pump unit BN-1
448times468times950 mm 578 kg
Reference standards Nuclear IEC 60761 IEC 61171 EMC IEC 61010 IEC 61000-6-2 Seismic IEC 60980
Alarmbull Sound alarm 80 divide 100 dBA at distance 1 mbull Visual alarm green yellow redbull Connection of the external alarm unit of ldquoBASrdquo
type
Versionsbull Stationary versionbull Stationary version with pump unit BN-1bull Mobile version with pump unit BN-1
Сontinuous automatic monitoring radioiodine concentration in the air at working places and in ventilation ducts and stacksbull Measurement of volumetric activity of radionu-
clides I-131 I-132 I-133 I-135 in the airbull On line gamma spectrometrybull Gamma background compensation bull Performance self-test by means of Am-241 check
source implanted into the detectorbull Audible and visual alarm signals of the excess of
preset thresholdsbull Periodic calibration by means of standard source
UDI-1B IODINE MONITOR
Physical characteristicsbull Silicon detector 2 pcs (for measurement and for
background rejection)bull Air flow rate 10 divide 100 lminbull Operation temperature range minus 10 divide +50 ordmС
Measurement range bull 104 divide 11010 Bqm3
Energy rangebull 006 divide 30 MeV
Electrical characteristicsbull Power supply 120 Vbull Interface RS-485
Mechanical characteristicsbull Protection index IP 65bull Paint decontaminable
Overall dimensions weight bull 474х246х243 mm 295 kg
UDG-03D NOBLE GAS MONITOR
Measurement of volumetric activity of beta-emitting radioactive gases (argon krypton xenon) adapted to the measurement of the rapidly changing volume activity in various technological processesbull Gamma background compensationbull Periodic calibration by means of standard beta-
source
Reference standards Nuclear IEC 60761 IEC 62302 EMC IEC 61010 IEC 61000-6-2 Seismic IEC 60980
Radiation monitoring system SPC ldquoDozardquo
20 21
Continuous automatic monitoring of steam genera-tor primary to secondary leakagebull On line gamma spectrometrybull N-16 monitoringbull Performance self-test by means of Am-241 check
source implanted into the detectorbull Audible and visual alarm signals of the excess of
preset thresholds
Physical characteristics
UDGP-01 STEAM GENERATOR LEAKAGE MONITOR
bull detector ndash scintillator CsI Oslash 40х100 mm
Measurement range bull High energy gamma-activity (N-16)
15bull103 divide 20bull108 Bqm3
bull General gamma-activity 10bull104 divide 20bull108 Bqm3
Energy range bull General gamma 005 divide 15 MeV bull in integral spectral band of energy
5000 divide 7200 keV bull temperature range minus 10 divide +80 ordmС
BOP-1SP
Electrical characteristicsbull Power supply 85 divide 260 V 47 divide 440 Hzbull Interfaces RS-232 RS-485 Ethernetbull programmable relay output (SPDT relay)
Mechanical characteristicsbull Protection index IP 65bull Paint decontaminable
Overall dimensions weight bull Detector unit Oslash 60x360 mm17 kgbull Data processing and transmission unit BOP-1sp
280x220x114mm 43 kgbull Collimator Oslash 350x455 mm 150 kg
Alarmbull Sound alarm 80 divide 100 dBA at distance 1 mbull Visual alarm green yellow redbull Connection of the external alarm unit of ldquoBASrdquo
type
Reference standards Nuclear IEC 61453 EMC IEC 61010 IEC 61000-6-2 Seismic IEC 60980Reference standards Nuclear IEC 60761 IEC 60710 IEC 60951-2 EMC IEC 61010 IEC 61000-6-2 Seismic IEC 60980
Ionization chambe 10 liters
UDGB-01T1
Physical characteristicsbull Detectors - stainless steel ionization chambersbull Air flow rate 10 divide 100 lminbull Operation temperature range minus 10 divide +50 ordmС
Volumes of ionization chambers bull UDGB-01T UDGB - 01T1 100 litersbull UDGB-01T2 01 liter
Measurement range (Kr-85) bull UDGB-01T UDGB-01T1 10104 divide 50109 Bqm3
bull UDGB-01T2 109 divide 501014 Bqm3
Measurement range (H-3) bull UDGB-01T UDGB-01T1 50104 divide 50109 Bqm3
bull UDGB-01T2 50109 divide 501014 Bqm3
Electrical characteristicsbull Power supply 85 divide 260 V 47 divide 440 Hzbull Interfaces RS-232 2timesRS-485 Ethernetbull Programmable relay output (SPDT relay)bull Analog output 4-20 mA (optional)
Mechanical characteristicsbull Protection index IP 23bull Paint decontaminable
Continuous automatic monitoring of the beta-emitting radioactive gases including tritium and carbon-14 concentration in the air at working places and in ventilation ducts and stacksbull Audible and visual alarm signals of the excess of
preset thresholds bull Monitoring of the noble gase activity in gaseous
effluents and ventilation air for accident and post-accident conditions
Overall dimensions weight bull UDGB-01T 381times343times716 mm 30 kgbull UDGB-01T1 260times320times175 mm 125 kgbull Ionization chamber 100 liters Oslash 250times600 mm
6 kgbull UDGB - 01T2 381times343times716 mm 27 kg
Alarmbull Sound alarm 80 divide 100 dBA at distance 1 mbull Visual alarm green yellow redbull Connection of the external alarm unit ldquoBASrdquo type
Versionsbull UDGB-01T - with built-in ionization chamber
100 litersbull UDGB-01T2 - with built-in ionization chamber
01 literbull UDGB-01T1 - with remote ionization chamber
100 liters
UDGB-01NOBLE GASESH-3C-14 MONITOR
Radiation monitoring system SPC ldquoDozardquo
22 23
Physical characteristicsLength of communication cablebull up to 1200 m
Character height bull ldquoImpuls-910-Rrdquo 100 mmbull ldquoImpuls-915-D4Srdquo 150 mmbull ldquoImpuls-927-D4Srdquo 270 mm
Operating temperature rangebull ldquoImpuls-910-Rrdquo 0 divide +50 ordmCbull ldquoImpuls-915-D4Srdquo ldquo-927-D4Srdquo minus 40 divide +50 ordmC
Electrical characteristicsbull Power supply 220 V 50 Hz
Mechanical characteristicsProtection index bull ldquoImpuls-910-R IP 44bull ldquoImpuls -915-D4Srdquo ldquo-927-D4Srdquo IP 65
Overall dimensions weight bull ldquoImpuls-910-Rrdquo 400times160times60 mm 3 kgbull ldquoImpuls -915-D4Srdquo 815times250times80 mm 5 kgbull ldquoImpuls -927-D4Srdquo 1250times330times80 mm 5 kg
ldquoIMPULSrdquoEXTERNAL DISPLAY UNIT
Display of data received from monitors of RMS
External display unit ldquoImpuls-910-Rrdquo
Reference standards EMC IEC 61010 IEC 61000-6-2 Seismic IEC 60980
Continuous monitoring of the flow rate temperature and humidity of the gas flowbull Definition of air volume flow rate in stacks taking
into account temperature and humidity of the air
UPPVM AIR FLOW PARAMETERS MONITOR
Physical characteristicsMeasurement range bull air flow velocity 1 divide 20 msbull air temperature 0 divide +80 ordmСbull air humidity 10 divide 95
Electrical characteristicsbull Power supply 220 V 50 Hz bull Interfaces RS-232 Ethernet
Mechanical characteristicsProtection index bull BSPP-1st BSPP-1tv BOP-1s IP 65bull PP-st IPTV IP 54bull Paint decontaminable
Overall dimensions weight bull air velocity probe PP-st 60times38times136 mm 015 kgbull Interface block BSPP-1st 125times155times73 mm 07 kgbull air temperature and relative humidity probe
IPTV-056-A 333times100times60 mm 07 kgbull Interface block BSPP-1tv 125times155times73 mm 07 kgbull Data processing and transmission unit BOP-1s
280x233x111 mm 8 kg
Reference standards Nuclear ISO 2889 EMC IEC 61010 IEC 61000-6-2 Seismic IEC 60980
BOP-1S
Radiation monitoring system SPC ldquoDozardquo
24 25
BASBAS-1S EXTERNAL ALARM
Generation of audible and visual signals of the excess of preset thresholds RMS monitorsbull Audible alarm 80 divide 100 dBA at distance 1 mbull Visual alarm green yellow red
Distance from RMS monitorbull BAS up to 20 mbull BAS-1s up to 1200 m
Power supply bull 220 V 50 Hz
Overall dimensions weight bull BAS 145times108times460 mm 18 kg bull BAS-1s 166times109times466 mm 18 kg
Reference standards EMC IEC 61010 IEC 61000-6-2 Seismic IEC 60980
Physical characteristicsLength of communication cablebull up to 1200 m
Displayed page size bull 4 lines of 20 characters
Volume of loaded information bull 10 pages
Change of pagesbull programmed or by pressing a button
Operating temperature rangebull minus 40 divide +50 ordmC
Electrical characteristicsbull Power supply 9 divide 18 VDCbull Interfaces RS-485
Mechanical characteristicsbull Protection index IP 65bull Overall dimensions weight 222times164times73 mm
40 kg
BI-2 REMOTE DISPLAY amp ALARM UNIT
bull Display of data received from monitors of RMSbull Audible and visual alarms on exceeding preset
thresholds of the RMS equipment bull Individual threshold setting for each measure-
ment channelbull Audible alarm 80 divide 100 dB at a distance of 1 m bull Visual alarm red yellow green
Reference standards EMC IEC 61010 IEC 61000-6-2 Seismic IEC 60980
Radiation monitoring system SPC ldquoDozardquo
2726
Electrical characteristicsbull Power supply 220 V 50 Hz bull Interfaces RS-232 RS-485 Ethernetbull programmable relay output (SPDT relay)
Alarmbull Sound alarm 80 divide 100 dBA at distance 1 mbull Visual alarm green yellow redbull Connection of the external alarm unit ldquoBASrdquo type
Related monitors and equipmentsbull UDA-1AB particulate monitorbull UDG-1B noble gas monitorbull UDI-1B iodine monitorbull UPPVM air flow parameters monitorbull Sampling and sample separation rack
Air flow parameters monitor rack
Reference standards Nuclear IEC 60761 IEC 61171 IEC 61172 IEC 62302 ISO 2889 EMC IEC 61010 IEC 61000-6-2 Seismic IEC 60980
Sampling and sample separation rack
Continuous monitoring of radioactivity in gaseous effluentsbull Automatic monitoring of the alpha- and beta-
radioactive aerosol noble gas and radioiodine concentrations in the air in ventilation ducts and stacks
bull Monitoring of the flow rate temperature and humidity of the gas flow
bull Separation of gaseous effluent into targeted fractions by means of a two-stage filter
bull Reversion of gas after analysis to the ventilation system
Physical characteristics
Particulate (UDA-1AB)bull Silicon specrometric detectors (2 pcs for measure-
ment and for gamma-background compensation) bull Filter tape types LFAS FSLWbull Tape consumption (when continuous operation)
10 m50 days
Measurement range bull Alpha 10-2 divide 2105 Bqm3 bull Beta 10-1 divide 106 Bqm3
Energy range bull Alpha 30 divide 90 MeV bull Beta 005 divide 30 MeV
Noble gas (UDG-1B)bull silicon detectors (2 pcs for measurement and for
gamma-background compensation)
Measurement range bull 104 divide 6109 Bqm3
Energy range bull 008 divide 30 MeV
Iodine (UDI-1B)bull scintillation detectors CsI(Tl) (2 pcs for measure-
ment and for background compensation)
SKGAV STACK MONITOR
Particulate noble gas and iodine monitors rack
Measurement range bull 37 divide 37105 Bqm3
Energy range bull 015 divide 30 MeV
Air flow parameters (UPPVM)Measurement range bull air flow velocity 1 divide 20 msbull air temperature 0 divide +80 ordmСbull air humidity 10 divide 95
Radiation monitoring system SPC ldquoDozardquo
28 29
CONFIGURATOR SOFTWAREMaintenance and set-up softwarebull Set-up and verify RMS monitorsbull Control testing adjustment and repair of RMS
monitorsbull Monitors measurement results archive receive
and View bull Communication through RS-232
RMS WORKSTATION ndash OPERATOR CONSOLEOrganization of interaction of the RMS Server and Monitors
Single monitor console includes vandal-proof key-board amp UPS
Reference standard IEC 61559-1 IEC 61559-2
RMS SOFTWAREData acquisition storing and visual representation RMS monitors measurement resultsbull Ethernet IEEE 8023 networkbull Clientserver architecturebull TCPIP protocolbull Oracle based Data Basebull Supremal by means InSat MasterSCADA
Radiation monitoring system SPC ldquoDozardquo
30 31
Delivery setComposition and modification depend on the tasks to be solved using the RM Rack
The rack which is an integral part of RM Rack accommodatesbull Monitors UDA-1AB UDG-1B UDG-03D UDI-1B
UDGB-01Tbull DBG-S11D Wide range gamma area monitor
BDMG-101 High range gamma area monitor UDMN-100 Neutron area monitor BDRG-52R High range gamma area monitor
bull BI-2 Remote display amp alarm unitbull Pump unit BN-01bull Data processing and transmission unit BOP-1Mbull External alarm BAS or BAS-1sbull Equipment of sampling line (flow meters ball
valves filter holder piping solenoid valve)bull Switchboard (intended for switching of all equip-
ment and transfer of data to the upper level via the unified communication channel)
RM RACK RADIATION MONITORING RACK
The radiation monitoring rack (RM Rack) is designed for continuous monitoring of radiation parameters in premises and technological systems at nuclear facil-ities RM Rack can be used as a structural element of the lower-level of RMS at nuclear power plants and other nuclear facilities that involved in obtaining processing use and storage of radioactive materials
FeaturesContinuous automatic monitoring of the alpha- and beta- radioactive aerosol beta-emitting radioactive gases and radioiodine concentrations in the working air and in the air in stacks and others radiation parameters in the facilities
The stand providesbull Primary processing storage and transmission of
measured and related data into the information channel based on the Ethernet IEEE 8023 inter-face (TCPIP protocol)
bull Transfer of required data to the location where the equipment is installed via technological channels based on RS-232 interface
bull Generation of audible and visual warning alarm signals when the preset thresholds are exceeded
bull Display of received data on the LCD
Radiation monitoring system SPC ldquoDozardquo
32 33Reference standards IEC 60860 ANSIANS-83 ISO 7753
Purposebull Detection and recording of criticality accident
(CA) by measuring the absorbed dose rate of gamma-neutron radiation in the premises of monitored object its comparison with a threshold value and generation of audible and visual signals
bull Automatic collection processing storage and display of measurement data and related infor-mation as visual and graphical representation for operators of nuclear safety service
Functions of the systembull Detection and recording of CA events by con-
tinuous measurement of absorbed dose rate of gamma radiation comparison of measured values with preset thresholds generation of signals to activate the alarm
bull Activation of audible visual alarmbull In the event of CA turning on warning signals
ldquoDO NOT ENTERrdquo at illuminated information pan-els placed at the entrances to the controlled area
Featuresbull Data can be transferred to external data commu-
nication channel using RS-485 interface (DiBus data exchange protocol)
bull Automatic self-testing of detection units BR-04D with display of information about the type of fault
bull Possibility for connecting additional a detection and alarm units
bull Ability to function in general regardless of the functioning of components within the agreed scope of nuclear safety tasks
bull Radiation hardness up to 100 Gy
SRKS-01DCRITICALITY ACCIDENT ALARM SYSTEM
Features of softwarebull Collection of information via RS-485 network
displaying it on the PC monitor transmission to remote users archiving and storage
bull Status monitoring and display of values measured by BR-04D and DBG-S11D in locations as per layout of premises
bull Access to archived data with possibility to gener-ate reports for periods determined by operator
bull Maintenance and archiving of a log of dosimetric measurements data and events along with their time stamps
bull Possibility to transfer data to external users via Ethernet network for integrating of CA into higher level systems
Basic complete setLower level bull Control unit with power supplybull BR-04D detection unitsbull BZS-01D audible alarm unitsbull BSS-01D visual alarm unitsbull SIT-01D illuminated warning signsbull PBZ panels for muting audible alarmbull Network communication module
Additional lower layer devicesbull DBG-S11D wide range gamma area monitor
Upper layer bull CDP central display panelbull Service workstation
RS-485
RS-485
RS-4
85
Audible alarm units BZS-01D
Illuminated warning signs SIT-01D
Detection units BR-04D
Network communication
moduleDBG-S11D wide range gamma area monitor
Panels for muting audible alarm
Control unit with power supply
Visual alarm units BSS-01D
RS-485
RS-485
RS-4
85
Audible alarm units BZS-01D
Illuminated warning signs SIT-01D
Detection units BR-04D
Network communication
moduleDBG-S11D wide range gamma area monitor
Panels for muting audible alarm
Control unit with pow-er supply
Visual alarm units BSS-01D
RS-485
RS-4
85
Audible alarm units BZS-01D
Illuminated warning signs SIT-01D
Detection units BR-04D
Network communication
moduleDBG-S11D wide range gamma area monitor
Panels for muting audible alarm
Control unit with power supply
Visual alarm units BSS-01D
RS-485
RS-485
RS-4
85
Audible alarm units BZS-01D
Illuminated warning signs SIT-01D
Detection units BR-04D
Network communication
moduleDBG-S11D wide range gamma area monitor
Panels for muting audible alarm
Control unit with power supply
Visual alarm units BSS-01D
Ethernet
Central display panel Service workstation
RS-485
RS-485
RS-4
85
BZS-01D audible alarm units
SIT-01D illuminated warning signs
BR-04D detection units
Network communication
moduleDBG-S11D wide range gamma area monitor
PBZ panels for muting audible alarm
Control unit with power supply
BSS-01D visual alarm units
Radiation monitoring system SPC ldquoDozardquo
34 35
ldquoBREEZErdquoHIGH-VOLUME AIR SAMPLER
Physical characteristicsbull Measurement range of air flow rate
250 divide 1200 m3hbull Continuous operation time not less than 24 h
Filter materialsbull High-purity glass fiberbull Pure quartz or cellulosebull Filter fabric FPP-15-15
Electrical characteristicsPower supply bull 220380 V 50 Hz
Interfaces bull RS-485bull Ethernetbull GSMGPRS (option)
Environmental characteristicsTemperature range bull minus 40 divide + 40 ordmC
Relative humidity limit at 35 ordmC bull 95
Atmospheric pressure range bull 840 divide 1067 kPa
Versionsbull Standalone unit bull Part of Environmental Radiation Monitoring
System (ERMS)
Type of detection unitsbull Beta block BDZB-100Lbull DBG-S11D wide range gamma area monitorbull Scintillation spectrometric block
The motor of Air Sampler is controlled by an electronic flow sensor that detects changes in the operators pre-set flow rate caused by changes in temperature barometric pressure and pressure drop due to dust loading on filter media It compensates for these changes by adjusting the motor speed to maintain the pre-set flow ratebull Measurement of parameters of ionizing radiation bull Standalone mode of operation or as the part
of Environmental Radiation Monitoring System (ERMS)
Purposebull Environmental Radiation Monitoring System
(ERMS) in the control and buffer areas of the radia-tion and nuclear facilities
Referencesbull Since the year 2000 the system is successfully
operating the ERMSs at 8 Russian nuclear power plants (about 180 monitoring stations)
bull Since the year 2005 the ERMS is operating in the Moscow (about 40 monitoring stations)
bull Since the year 2005 the regional ERMS is under operation in several Russian Federation regions
Basic complete setMonitoring stations bull Data processing and transmission unit BOP-1TA bull Gamma area monitor DBG-S11D
Central data processing station (CDPS)bull Data processing and transmission unit BOP-1TAbull Server
By requestbull Emergency Response and Crisis Management
Centers for enterprisesbull Regional Emergency Response and Crisis Manage-
ment Centersbull rdquoBreezerdquo High-Volume Air Samplerbull Mobile lab with gamma-survey system rdquoGammandash
sensorrdquo
ldquoATLANT-MrdquoENVIRONMENTAL RADIATION MONITORING SYSTEM
Monitoring system for the continuous radiation monitoring of territories and facilities with the data transmission GSMGPRS network
Data transmission bull GSMGPRS
Power supply bull 220 V 50 Hz
Continuous autonomous operation (at 20 ordmC)bull From built-in battery not less than 5 hoursbull From external battery not less than 24 hours
Operation temperature bull Minus 40 divide +50 ordmC
Operation humidity bull Up to 98
Protection bull IP65
Reference standards Nuclear IEC 61017-11991 IEC 61017-21994
36
Radiation Monitoring Equipment
bull Localization of radioactive contaminationsbull Database with dose rate contaminations
spectra measurement date amp time coordi-nates
bull Work as part of mobile laboratory or as part of Environmental Radiation Monitoring System with real-time data transfer
Physical characteristicsDetector bull Scintillation NaI (Tl) GM counters
Measurement rangebull 01 ndash 107 μSvh
Energy range bull 005 ndash 3 MeV
Operation temperature range bull minus 10 divide +50 ordmС
Electrical characteristics bull Power supply 220 V 50 Hz
ldquoGAMMAndashSENSORrdquoGAMMA-SURVEY SYSTEM
SPC ldquoDozardquoRadiation monitoring equipment
38 39
AREA MONITOR ldquoFREGATrdquoArea Monitor ldquoFregatrdquo is designed for building rela-tively simple and inexpensive radiation monitoring systems at such facilities as radionuclide sources storage areas isotope products warehouses nuclear medicine departments PET centers calibration laboratories where sources of ionizing radiation are used etc
Small scale automated radiation monitoring systems built with ldquoFregatrdquo components featuring audible and visual alarms are matched suitable to meet the regulatory radiation safety requirements
Area monitor ldquoFregatrdquo requires virtually no adjust-ment it is simple and convenient for installation and operation
BPI-1D LOCAL DISPLAY UNIT
Display of monitored parameters values received from external measuring devices
Purposebull Processing and display of values of monitored
parameters on information panel bull Comparison of values of monitored parameters
with thresholdsbull Transfer of monitored parametersrsquo values to
networkbull Generation of alarm in case of exceeding of preset
thresholds including external alarm devices
FeaturesTesting the unit and connected devicesbull Visually on the panelbull Using adjustment software when connected to
PC via USB
Automatic self-testing
The panel displays the following informationbull Diagnostic information about the status of con-
nected devicesbull Current date and timebull Values of measured parametersbull Position of measured values with respect to the
thresholds in the form of scales with green yellow and red zones
bull Time history (trend) for each measured value
Physical characteristicsTemperature range bull minus 10 divide + 50 ordmC
Maximum number of connected devicesbull measuring devices 15bull external audible and visual alarm 15
Display diagonal bull 152 cm (6)
Electrical characteristicsbull Interfaces RS-485bull Power supply 220 V 50 Hz 12 divide 24 V
Mechanical characteristicsbull Protection index IP54bull Paint decontaminable
Overall dimensions weightbull 296x248x118 mm 5 kg
DBG-S11D wide range gamma area monitor
UDMN-100 neutron area monitor
Ethernet RS-485
UDKS-100 gamma and X-ray area monitor
BPI-1D Local display unit
BAS-2 ldquoMicrordquo external visual alarm
BZS-2 ldquoMicrordquo external audible alarm
ldquoImpulsrdquo external display unit
Service workstation
Illuminated warning signs
SPC ldquoDozardquoRadiation monitoring equipment
4140
Continuous automatic monitoring of the gamma- X-ray ambient dose equivalent rate
Physical characteristicsbull Detector tissue-equivalent plastic scintillator
Oslash 45times20 mm
Measurement range bull Dose rate measurement range 01 μSvh divide 1 Svh bull Energy range 0015 divide 10 MeV
Mechanical characteristicsbull Protection index IP65bull Paint decontaminable
Overall dimensions weightbull Oslash72times265 mm 15 kg
UDKS-100 GAMMA AND X-RAY AREA MONITOR
UDMN-100 NEUTRON AREA MONITOR
Physical characteristicsbull detector ndash scintillator ZnS(Ag) Li-6
Measurement range bull 01 μSvh divide 01 Svh
Energy range bull 0025 eV divide 100 MeV
Temperature range bull minus 45 divide +50 ordmC
Electrical characteristicsbull Interfaces RS-485
Mechanical characteristicsbull Protection index IP 65bull Paint decontaminable
Overall dimensions weight bull 428times258times347 mm 115 kg
Continuous automatic monitoring of the neutron-radiations ambient dose equivalent ratebull Spherical polyethylene moderator Oslash 239 mm
MEASURING UNITS
DBG-S11D WIDE RANGE GAMMA AREA MONITOR
Continuous automatic monitoring of the gamma- ambient dose equivalent rate
Physical characteristicsbull Detector ndash GM counters
Measurement rangebull DBG-S11D 01 μSvh divide 10 mSvhbull DBG-S11D-01 01 μSvh divide 10 Svhbull DBG-S11D-02 01 μSvh divide 100 Svh
Energy rangebull 005 divide 30 MeV
Temperature range bull minus 40 divide +50 ordmC
Electrical characteristicsbull Interfaces RS-485 USB
Mechanical characteristicsbull Protection index IP 68bull Paint decontaminable
Overall dimensions weightbull DBG-S11D Oslash 68times141 mm 065 kg bull DBG-S11D-01 Oslash 68times179 mm 07 kgbull DBG-S11D-02 Oslash 68times179 mm 07 kg
Versionsbull DBG-S11Dbull DBG-S11D-01bull DBG-S11D-02
Reference standards Nuclear IEC 60846 IEC 60532 EMC IEC 61010 IEC 61000-6-2 Seismic IEC 60980
SPC ldquoDozardquoRadiation monitoring equipment
4342
ALARM UNITS
Generation visual signals of the excess of preset thresholds
Physical characteristicsLength of communication cablebull up to 1200 mbull Alarm Visual alarm green yellow red
Electrical characteristicsbull Power supply +12 V
Mechanical characteristicsbull Protection index IP 23
Overall dimensions weight 160times84times41 mm 02 kg
BAS-2 ldquoMICROrdquo EXTERNAL VISUAL ALARM
Generation audible signals of the excess of preset thresholds
Physical characteristicsLength of communication cablebull up to 1200 mbull Audible alarm 80 divide 100 dB at a distance of 1 m
Electrical characteristicsbull Power supply +12 V
Mechanical characteristicsbull Protection index IP 23
Overall dimensions weight 160times84times41 mm 02 kg
BZS-2 ldquoMICROrdquo EXTERNAL AUDIBLE ALARM
Physical characteristicsLength of communication cablebull up to 1200 m
Electrical characteristicsbull Power supply 220 V 50 Hz
Mechanical characteristicsbull Protection index IP 23
Overall dimensions weight bull 330times110times20 mm 05 kg
Physical characteristicsLength of communication cablebull up to 1200 m
Character height bull ldquoImpuls-910-Rrdquo 100 mmbull ldquoImpuls-915-D4Srdquo 150 mmbull ldquoImpuls-927-D4Srdquo 270 mm
Operating temperature rangebull ldquoImpuls-910-Rrdquo 0 divide +50 degCbull ldquoImpuls-915-D4Srdquo ldquo-727-D4Srdquo minus 40 divide +50 degC
Electrical characteristicsbull Power supply 220 V 50 Hz
Mechanical characteristicsProtection index bull ldquoImpuls-910-R IP 44bull ldquoImpuls-915-D4Srdquo ldquo-727-D4Srdquo IP 65
Overall dimensions weight bull ldquoImpuls-910-Rrdquo 400times160times60 mm 3 kgbull ldquoImpuls-915-D4Srdquo 815times250times80 mm 5 kgbull ldquoImpuls-927-D4Srdquo 1250times330times80 mm 5 kg
ILLUMINATED WARNING SIGNS
ldquoIMPULSrdquo EXTERNAL DISPLAY UNIT
SPC ldquoDozardquoRadiation monitoring equipment
4544
Individual threshold setting for each measurement channel
Continuous area and process monitoring
Collect amp display data from two measurement chan-nels (units with RS-485 or analog pulses)
Audible and visual alarms on exceeding preset thresholds or status of connected devices
Individual threshold setting for each measurement channel
Switching on the external alarm or executive devices when any threshold is exceeded
The wide panel displays the following information bull Values of measured parameters as min-1∙cm-2
s-1∙cm-2 μSvhbull Diagnostic information about the status of con-
nected devicesbull Current date and timebull Position of measured values with respect to the
thresholds in the form of scales with green yellow and red zones
bull Time history (trend) for each measured value
Physical characteristics Measurement range bull Count rate up to 107 CPM (170 kHz)
Operating temperature range bull minus 20 divide +50 ordmC
Electrical characteristics bull Power supply 220 V bull Interfaces USB
Mechanical characteristics bull Protection index IP 65 bull Overall dimensions weight 222times164times73 mm
40 kg
UIM-3D AREA MONITOR COUNT RATE METER
Measurement of alpha radiation flux density
Detector unit BDZA-100 (70 cm2) Measurement range 01 divide 104 min-1∙cm-2
Detector unit BDZA-100B (300 cm2) Measurement range 01 divide 2103 min-1∙cm-2
Measurement of beta radiation flux density
Detector unit BDZB-100 (28 cm2) Measurement range 10 divide 105 min-1∙cm-2
Detector unit BDZB-100L (30 cm2) Measurement range 10 divide 104 min-1∙cm-2
Detector unit BDZB-11D (84 cm2) Measurement range 5 divide 15∙104 min-1∙m-2
OPTIONAL PROBESMeasurement of gamma radiation flux density
Detector units BDEG-03 Measurement range 4 divide 2000 s-1∙cm-2
Detector unit UDKG-100 for operation in the rocks ore liquid media and sludge Measurement range 40 divide 8000 s-1∙cm-2
Measurement of the ambient dose equivalent rate
Detector unit DBG-S11D Measurement range 01 μSvh divide 100 Svh
Measurement of neutron radiation ambient dose equivalent rate
Detector unit BDMN-100 Measurement range 01 μSvh divide 01 Svh
SPC ldquoDozardquoRadiation monitoring equipment
46 47Reference standards Nuclear IEC 61526
Measurement of gamma-radiation personal dose equivalent Hp(10)bull Stand-alone dosimeter or composed of dosimetric
system onebull Audible and visual alarmbull Large memory dose accumulation historiesbull Exclusion of unauthorized intervention in dosim-
etry operation
DKG-05D PERSONAL GAMMA DOSIMETER
Physical characteristicsDetectors bull Silicon
Measurement range bull Dose rate 1 μSvh divide 10 Svhbull Dose 01 μSv divide 15 Sv
Energy range bull 005 divide 30 MeV
Electrical characteristicsbull Power supply rechargeable NiMH battery 1
alcaline battery (type AAA)
Operation timebull Till recharging not less 400 hoursbull With one set batteries not less 1000 hours
Mechanical characteristicsOverall dimensions weight bull 47times26times87 mm (with clip) 70 g
Environmental characteristicsbull IP65bull Temperature range minus 20 divide +45 ordmCbull Humidity up to 98 at 35 ordmCbull Shock vibration and drop resistant
Alarmbull Excess of alarm thresholdsbull Warnings of self-test failure and battery discharge bull Audible alarm 80 dB at 40 cmbull Visual alarm blinking LED
Relative equipmentbull One dosimeter charger ZU-1Mbull Chargestorage cassetes KZU-28KZU-56bull ldquoSmart chargingrdquo feature extends battery life timebull DKG-05D reader US-05bull DKG-05D system reader DVS-01D
Reader-PC interfacebull US-05 USB bull DVS-01D Ethernet
KZU-28
Physical characteristicsDetectors bull Silicon Li-6
Gamma measurement range bull Dose rate 1 μSvh divide 10 Svhbull Dose 01 μSv divide 15 Sv
Gamma energy range bull 005 divide 60 MeV
Neutron measurement range bull Dose rate 1 μSvh divide 2 Svhbull Dose 20 μSv divide 15 Sv
Neutron energy range bull 0025 eV divide 20 MeV
Electrical characteristicsPower supply bull Rechargeable NiMH batterybull Operatiion time till recharging not less 200 hours
Mechanical characteristicsOverall dimensions weight bull 47times26times87 mm (with clip) 70 g
Environmental characteristicsbull IP65bull Temperature range minus 20 divide +40 ordmCbull Humidity up to 75 at 30 ordmCbull Shock vibration and drop resistant
Alarmbull Excess of alarm thresholds bull Warnings of self-test failure and battery discharge bull Audible alarm 80 dB at 40 cmbull Visual alarm blinking LED
Relative equipmentbull One dosimeter charger ZU-1Mbull Chargestorage cassetes KZU-28 KZU-56bull ldquoSmart chargingrdquo feature extends battery life timebull DVS-02D reader UZS-01Sbull DVS-02D system reader DVS-01D
Reader-PC interfacebull UZS-01S USB bull DVS-01D Ethernet
UZS-01DReference standards Nuclear IEC 61526
DVS-02D GAMMA-NEUTRON PERSONAL ELECTRONIC DOSIMETER
Measurement of gamma- and neutron radiations personal dose equivalent Hp(10)bull Stand-alone dosimeter or composed of dosimetric
system onebull Audible and visual alarmbull Large memory dose accumulation historiesbull Exclusion of unauthorized intervention in dosim-
etry operationbull Both albedo thermal neutrons and intermediate
fast neutrons registrationbull Usable in the fields of Pu(Be) Po(Be) Cf and other
neutron sources as well as near nuclear reactors without neutron spectrum estimation
SPC ldquoDozardquoRadiation monitoring equipment
48 49
Dosimeters DVG-03D
DVGI-8D NEW PEN-TYPE PERSONAL IONIZATION CHAMBER DOSIMETERS
Measurement of personal dose equivalent Hp(10) of gamma and X-ray radiationbull Hp(10) of continuous and pulsed gamma and
X-ray radiation bull Electronic reader KSU-1bull Dosimeter DVG-03D with electronic ID bull Personal dose histories in the readerrsquos memorybull Readerrsquos connection with PC for database main-
tenance
Physical characteristicsDetector bull Ionization chamber
Measurement range bull 001 mSv divide 25 mSv
Energy range bull 0015 divide 25 MeV
Temperature range bull Reader KSU-1 +10 divide +50 ordmСbull Dosimeter DVG-03D minus 40 divide +50 ordmС
Electrical characteristicsPower supply bull Reader KSU-1 220 V 50 Hz built-in batteries bull Dosimeter DVG-03D four batteries CR 1025 bull Batteries life 3 yearsbull Readers interfaces RS-232USB 20
Mechanical characteristicsOverall dimensions weightbull Dosimeter DVG-03D Oslash 18times126 mm 005 kgbull Reader KSU-1 235times232times125 mm 28 kg
Reference standards Nuclear IEC 62387-1
DKG-02U ldquoARBITERrdquo WIDE RANGE GAMMA-DOSIMETER
Physical characteristicsDetectors bull GM counters
Measurement rangebull Dose-rate 01 μSvh divide 3 Svhbull Dose 1 μSv divide 100 Sv
Energy range bull 005 divide 3 MeV
Electrical characteristicsbull Power supply 2 alcaline batteries (type AA)bull Batteries life not less 200 hours
Mechanical characteristicsOverall dimensions weight bull 152times82times32 mm 03 kg
Environmental characteristicsbull Temperature range minus 20 divide +50 ordmCbull Humidity up to 90 at +25 ordmCbull Shock vibration and drop resistant
Reference standards Nuclear IEC 60846
Measurement of gamma radiation ambient equiva-lent dose H(10) and dose rate H(10)bull Audible signals (clicks) for radiation condition
estimationbull Analog scale for search modebull Audible and visual alarms of the excess of preset
dose and dose rate thresholds bull Shock-resistant water-proof easy decontamina-
tion casebull 100 measurement results memory with date and
time of measurementbull Indication of total dose accumulated during
exploitation time bull Indication of measurement result statistical
uncertainty
SPC ldquoDozardquoRadiation monitoring equipment
50 51
Physical characteristicsDetectors bull GM counter
Measurement rangebull Dose-rate 01 μSvh divide 3 mSvhbull Dose 1 μSv divide 02 Sv
Energy range bull 005 divide 3 MeV
Temperature range bull Minus 20 divide +50 ordmC
Electrical characteristicsbull Power supply 2 alcaline batteries 15 V (type AA)bull Batteries life not less 200 hours
Mechanical characteristicsOverall dimensions weight bull 122times74times29 mm 025 kg
Reference standards Nuclear IEC 60846
DKG-07D ldquoDROZDrdquoGAMMA-DOSIMETER
Measurement of gamma radiation ambient equiva-lent dose H(10) and dose rate H(10)bull Two independent measurement channels dose
and dose ratebull Audible signals (clicks) for radiation condition
estimationbull Continuous measurement with updating meas-
urement resultbull Measurement result can be obtained with any
desired statistical uncertainty (error)bull Automatic restart when radiation level sharply
changesbull Indication of statistical uncertainty (error) during
measurement process
Continuous measurement with updating measure-ment result
Automatic restart when radiation level sharply changes bull Gamma dose H(10) and dose-rate H(10) meas-
urementbull Beta and gamma contamination surveybull Indication of statistical uncertainty during the
measurementbull Continuous measurement with accuracy increas-
ing with time bull Automatic restart triggered by change of gamma
dose-ratebull Compensation of gamma count rate while meas-
uring beta radiationbull Indication of battery charge levelbull Audible signal of the excess of preset threshold
Physical characteristicsDetectors bull GM counter
Measurement range bull Dose-rate 01 microSvh divide 20 mSvhbull Dose 1 microSv divide 100 Svbull Beta flux density (for Sr-90+Y-90)
10 divide 105 cm-2 min-1
Energy range bull Gamma 005 divide 3 MeVbull Beta 01 divide 3 MeV
Temperature range bull Minus 20 divide +50 ordmC
MKS-15D ldquoSnegirrdquo backside
MKS-15D ldquoSNEGIRrdquoMULTI ndash PURPOSE RADIATION SURVEY METER
Reference standards Nuclear IEC 60846 IEC 60325
Electrical characteristicsbull Power supply 2 alcaline batteries (type AA)bull Battery life not less 400 hours
Mechanical characteristicsOverall dimensions weight bull 124times72times35 mm 035 kg
SPC ldquoDozardquoRadiation monitoring equipment
52 53
Physical characteristicsDetectorbull GM counter
Measurement range bull 01 μSvh divide 20 mSvh
Energy range bull 005 divide 30 MeV
Threshold setting range bull 03 μSvh divide 20 mSvh
Step change of the thresholdbull In the range 03 divide 10 μSvh with the step
001 μSvhbull In the range 10 divide 100 μSvh with the step
01 μSvhbull In the range 100 divide 2000 μSvh with the step
10 μSvh
Electrical characteristicsPower supply bull 220 V 50 Hz bull Relay output
Mechanical characteristicsProtection index bull IP 40
Overall dimensions weight bull 226times120times75 mm 07 kg
Alarmbull Sound alarm 80 divide 100 dBA at distance 1 mbull Visual alarm redbull Connection of the external alarm signaling unit
Reference standards Nuclear IEC 60846 IEC 60532
Continuous automatic monitoring of the ambient dose equivalent rate bull Measurement of gamma dose rate H(10)bull Audible and visual alarm signals for preset
thresholdsbull Switching on the external signaling or executive
devices
SRPS-05D GAMMA MONITOR
Measurement ofbull Gamma and X-ray personal dose equivalent
Hp(10)bull Neutron personal dose equivalent Hp(10)bull Lens dose equivalent Hp(3)bull Skin dose equivalent Hp(007)bull TLD reader day-to-day tests using built-in LEDbull No needs nitrogen for heating
Physical charachteristicsDetectors bull 7LiF Mg Ti (gamma beta)bull 6LiF Mg Ti (neutron)
Gamma and X-ray Hp(10) Measurement range bull 500 μSv divide 10 Sv
Energy range bull 0015 divide 30 MeV
Neutron Hp(10)Measurement range bull 01 mSv divide 100 mSv
Energy range bull 0025 eV divide 10 MeV
Beta and photons Hp(007) Hp(3) Measurement range bull 2 mSv divide 100 Sv
Energy range bull Beta 025 divide 35 MeVbull Photons lt15 keV
Mechanical characteristicsDosimeters overall dimensions weight bull Gamma Hp(10) DTL-2 holder - 62times26times16 mm
16 gbull DTU holder - 42times28times18 mm 8 gbull Lens Hp(3) face skin Hp(007) Oslash 32times16 mm 9 gbull Finger skin Hp(007) 90times20times2 mm 1 gbull Neutron gamma Hp(10) 48times40times20 mm 30 g
Reference standards Nuclear IEC 61066
DTL-2 DTU-2
MKD (A-type) DVNG-M
DOZA-TLD MULTIPURPOSE TLD SYSTEM
SPC ldquoDozardquoRadiation monitoring equipment
54 55
Continuous and pulsed gamma and X-ray dose H(10) and dose-rate measurementbull Alpha beta and gamma contamination surveybull Neutron dose H(10) and dose-rate measurementbull Gamma radiation flux density in boreholes and
liquid media measurement
Electrical characteristicsPower supply bull UIK-05 four C-size batteriesbull UIK-05-01 rechargeable batterybull UIK-06 rechargeable battery
Interfaces bull RS-232bull USB (via adapter)
bull Detector type automatic determination and corre-sponding measurement modes selection
bull Alarm threshold settings ndash for dose dose-rate alpha and beta contaminations
bull ldquoDetectrdquo and ldquoLocaterdquo modes for survey probes
Reference standards Nuclear IEC 60846 IEC 60325 IEC 61005 IEC 62363
Case
UIK-06 control unit165times78times48 mm 03 kg
DKS-96UNIVERSAL RADIATION SURVEY METER
UIK-05 control unit202times86times90 mm 10 kg
BDZA-96
BDZA-96B
BDZA-96M
BDZA-96S
BDZA-96T
EXTERNAL PROBES ALPHAALPHA BDZA-96Detector bull ZnS(Ag) 70 cm2
Measurement range (for Pu-239)bull 01 divide 104 min-1cm-2
Overall dimensions weightbull Oslash 130times240 mm 11 kg
ALPHA BDZA-96BDetector bull ZnS(Ag) 300 сm2
Measurement range (for Pu-239)bull 01 divide 2103 min-1cm-2
Overall dimensions weightbull Oslash 230times290 mm 40 kg
ALPHA BDZA-96MDetector bull ZnS(Ag) 10 сm2
Measurement range (for Pu-239)bull 01 divide 105 min-1cm-2
Overall dimensions weightbull Oslash 65times240 mm 09 kg
ALPHA BDZA-96SDetector bull ZnS(Ag) 30 сm2
Measurement range (for Pu-239)bull 01 divide 5104 min-1cm-2
Overall dimensions weightbull Oslash 90times240 mm 10 kg
ALPHA BDZA-96TDetector bull Silicon 5 сm2
Measurement range (for Pu-239)bull 01 divide 106 min-1cm-2
Overall dimensions weightbull Oslash 50times60 mm 015 kg
SPC ldquoDozardquoRadiation monitoring equipment
56 57
BETA BDZB-96Detector Scintillator 28 сm2
Measurement range (for Sr-90+Y-90)bull 10 divide 105 min-1cm-2
Energy rangebull 03 divide 30 MeV
Overall dimensions weightbull Oslash 90times230 mm 09 kg
BETA BDZB-99Detector bull GM counter 30 сm2
Measurement range (for Sr-90+Y-90)bull 20 divide 104 min-1см-2
Energy rangebull 012 divide 30 MeV
Overall dimensions weightbull Oslash 88times80 mm 04 kgbull Telescopic pole length 07 m
BETA BDZB-96BDetector bull GM counter 80 сm2
Measurement range (for Sr-90+Y-90)bull 3 divide 104 min-1сm-2
Energy rangebull 012 divide 30 MeV
Overall dimensions weightbull 150times200times110 mm 15 kg
BETA BDZB-96Sbull Detector GM counter 15 сm2
Measurement range (for Sr-90+Y-90)bull 10 divide 3104 min-1cm-2
Energy rangebull 012 divide 30 MeV
Overall dimensions weightbull Oslash 65times65 mm 03 kgbull Telescopic pole length 07 m
BDZB-96
BDZB-99
BDZB-96B
BDZB-96S
EXTERNAL PROBES BETA
GAMMA BDKS-96BDetector bull Tissue-equivalent scintillator Oslash 45times20 mm
Measurement rangebull Dose rate H(10) 01 μSvh divide 1 Svhbull Dose H(10) 01 μSv divide 10 Sv
Energy rangebull 0015 divide 10 MeV
Overall dimensions weightbull Oslash 60times250 mm 085 kg
GAMMA AND BETA BDKS-96SDetector bull Double GM counters
Measurement rangebull Gamma dose rate H(10) 01 μSvh divide 1 mSvhbull Gamma dose H(10) 01 μSv divide 10 Svbull Beta 10 divide 3104 min-1cm-2
Energy rangebull Gamma 005 divide 3 MeVbull Beta 012 divide 3 MeV
Overall dimensions weightbull Oslash 80times80 mm 035 kgbull Telescopic pole length 07 m
GAMMA BDMG-96Detector bull GM counters
Measurement rangebull Dose rate H(10) 01 μSvh divide 10 Svhbull Dose H(10) 01 μSv divide 10 Sv
Energy range bull 005 divide 3 MeV
Overall dimensions weightbull 40times250 mm 05 kgbull Telescopic pole length 07 m 4 m (by request)
EXTERNAL PROBES GAMMA
BDKS-96B
BDMG-96
BDKS-96S
SPC ldquoDozardquoRadiation monitoring equipment
58 59
GAMMA-SEARCH BDVG-96Detector bull Scintillator NaI(Tl) Oslash 63times63 mm
Measurement rangebull Flux density measurement range 4 divide 2000 s-1cm-2
bull Dose rate H(10) for Cs-137 01 divide 30 μSvhbull Sensitivity for Cs-137 3000 (pulsess-1)( μSvh-1)
Overall dimensions weightbull Oslash 88times400 mm 20 kgbull Modular pole length 16 m
GAMMA-SEARCH BDPG-96Detector bull Scintillator NaI(Tl) Oslash 25times40 mm
Measurement rangebull Flux density measurement range 10 divide 8000 s-1cm-2
bull Dose rate H(10) for Cs-137 01 divide 100 μSvhbull Sensitivity for Cs-137 500 (pulsess-1)( μSvh-1)
Overall dimensions weightbull 50times190times480 mm 10 kgbull Telescopic pole length 07 m
GAMMA-SEARCH BDPG-96MDetector bull Scintillator NaI(Tl) Oslash 18times30 mm
Measurement rangebull Flux density measurement range 10 divide 24000 s-1cm-2
bull Dose rate H(10) for Cs-137 01 divide 300 μSvhbull Sensitivity for Cs-137 200 (pulsess-1)( μSvh-1)
Overall dimensions weightbull Oslash 35times320 mm 05 kgbull Telescopic pole length 07 or 38 m
EXTERNAL PROBES GAMMA
BDVG-96
BDPG-96M
BDPG-96
EXTERNAL PROBESGAMMA BDKG-96 STAINLESS STEEL CASING FOR GEOLOGIC APPLICATIONS WELL LOGGINGDetector bull Scintillator NaI(Tl) Oslash 18times30 mm
Measurement rangebull Flux density measurement range 10 divide 105 s-1cm-2
bull Dose rate H(10) for Cs-137 5 divide 2104 μRhbull Sensitivity for Cs-137 200 (pulsess-1)( μSvh-1)
Overall dimensions weightbull Oslash 38times535 mm 36 kgbull Cable length 10 divide 1000 m
NEUTRON BDMN-96Detector bull Scintillator with ZnS(Ag)
Measurement rangebull Dose rate H(10) 01 μSvh divide 01 Svhbull Dose H(10) 01 μSv divide 10 Sv
Energy range bull 0025 eV divide 10 MeV
Overall dimensions weightbull Detector Oslash 54times200 mm 08 kgbull Moderator Oslash 245 mm 73 kg
NEUTRON-SEARCH BDKN-96Detector bull He-3 counter in polyethilene moderator
Measurement rangebull Dose rate H(10) for Pu-Be 01 μSvh divide 01 Svhbull Dose H(10) for Pu-Be 01 μSv divide 10 Sv
Energy range bull 0025 eV divide 14 MeV
Overall dimensions weightbull 295times142times100 mm 225 kg
BDKG-96M
BDMN-96
BDKN-96
SPC ldquoDozardquoRadiation monitoring equipment
60 61
bull No gas supply neededbull Clothing control detachable right hand detector bull Alpha detector optional connection bull Numeric and color (red green) indication of
control resultsbull LED sensor of hand-foot positioning for start of
measurementbull Automatic compensation of gamma background
and contamination of detectorbull Audible alarm signals of the excess of preset
thresholdsbull Measurement value indication min-1cm-2 or
Bqсm2
Reference standards Nuclear IEC 61098
RZB-05D HAND-FOOT-CLOTHING MONITOR
Physical characteristicsDetectors bull Gamma beta - GM countersbull Alpha - scintillatior ZnS(Ag)
Detecting nuclidesbull Alpha Pu-239 U-234 U-238bull Beta Sr-90+Y-90 F-18 Cs-137 Co-60 Tс-99 O-15
N-13 Sr-89 C-11 I-131 Na-22 Ru-106+Rh-106 Tl-204
bull Gamma Tc-99m I-123
Efficiencybull Alpha
Pu-239 40 U-234 25U-238 15
bull Beta Sr-90 +Y-90 40
Measurement range bull Alpha 1 divide 103 min-1cm-2 bull Beta 10 divide 103 min-1cm-2
bull Gamma 5103 divide 5106 min-1cm-2
Energy range bull Alpha 30 divide 80 MeV bull Beta 008 divide 35 MeV bull Gamma 005 divide 30 MeV
Operation temperature range bull Minus 10 divide +50 ordmС
Electrical characteristicsbull Power supply 220 V 50 Hz
Mechanical characteristicsOverall dimensions weight bull 740times750times1180 mm 45 kg
Versionsbull Withwithout alpha detectorbull Indication (min-1cm-2 ) or (Bqсm2)bull Detectors overall dimensions smbull Hand 178 х 235bull Foot 185 х 436
Whole body contamination monitor RZBA-04-04Mbull No gas supply neededbull Compensation for background gamma radiation
and contamination of detector unitsbull Individual threshold setting for each measure-
ment channelbull Visible and audible alarms ldquoCONTAMINATIONrdquo and
ldquoCLEANrdquo bull Indication of contaminated body parts on the
panel with image of the bodybull Optional remote alpha-detector
Physical characteristicsDetectors bull Beta - GM counters scintillatorsbull Alpha - scintillatior ZnS(Ag)
Measurement range bull Beta 5 divide 15000 min-1cm-2
bull Alpha 01 divide 10000 min-1cm-2
Energy range bull Beta 015 divide 25 MeV bull Alpha 40 divide 56 MeV
Operation temperature range bull +5 divide +50 ordmС
Electrical characteristicsPower supply bull 220 V 50 Hz
Interfaces bull RS-232bull RS-485
Mechanical characteristicsOverall dimensions weight bull 2650times940times930 mm 310 kg
Versionsbull Withwithout alpha detectorbull Indication (min-1cm-2 ) or (Bqсm2)
Reference standards Nuclear IEC 61098
RZBA-04-04MWHOLE BODY CONTAMINATION MONITOR
SPC ldquoDozardquoRadiation monitoring equipment
62 63
RZA-05DALPHA HAND-MONITOR
bull No gas supply needed bull Numeric and color (red green) indication of
control resultsbull LED sensor of hand- positioning for start of
measurementbull Audible alarm signals of the excess of preset
thresholdsbull Measurement value indication min-1cm-2 or
Bqсm2
Physical characteristicsDetectors alpha - scintillatior ZnS(Ag)
Efficiencybull Pu-239 20 bull U-234 14bull U-238 8
Measurement range bull 05 divide 105 min-1cm-2
Energy range bull 41 divide 90 MeV
Operation temperature range bull minus 10 divide +50 ordmС
Electrical characteristicsPower supply bull 220 V 50 Hz
Mechanical characteristicsOverall dimensions weight no more bull 740times1400times1450 mm 70 kg
Reference standards Nuclear IEC 61098
bull Simultaneous measurement of alphabeta activi-ties in the sample
bull Active shielding anti-coincidence background subtraction using GM counters
bull Lead shielding 30 mm
UMF-2000 LOW LEVEL ALPHA- BETA- COUNTER
Physical characteristicsDetectors bull Silicon specrometric detector 500 or 1000 mm2
Measurement range bull Alpha 001 divide 1000 Bq bull Beta 01 divide 3000 Bq
Energy range bull Alpha 35 divide 80 MeV bull Beta 005 divide 35 MeV
Electrical characteristicsPower supply bull 220 V 50 Hz
Interfaces bull RS-232bull USB
Mechanical characteristicsOverall dimensions weight bull 337times286times190 mm 22 kg
Versionsbull Detector area 500 mm2
bull Detector area 1000 mm2
UMF-2000 Detector area 1000 mm2
UMF-2000 Detector area 500 mm2
SpectraDec software for alpha-spectrometric measurements
SPC ldquoDozardquoRadiation monitoring equipment
64 65
DRK DOSE AREA PRODUCT METER
DRK-1bull Diagnostic reference level (DRL) of patients
determinationbull Suitable for all basic types of x-ray machines
Physical characteristicsDetector bull Plane-parallel ionization chamber
Measurement range bull 1 divide 104 cGycm2
Electrical characteristicsPower supply bull 220 V 50 Hz
DRK-1M-CTbull Measuring of dose length product
Physical characteristicsDetector bull Pencil Ionization Chamber
Measurement rangebull 05 divide 109 microGym
DRK-1Mbull Measuring of air kerma on sectional area of the
X-ray beam productbull Measuring of air kerma rate on area productbull Measuring of air kerma ratebull Measuring of air kerma
Physical characteristicsDetector bull Plane-parallel ionization chamber
Measurement rangebull 01 divide 109 microGym2
bull 06 divide 6104 microGym2cbull 30 divide 9105 microGycbull 30 divide 9991011 microGyReference standard IEC 60580 2003
bull Measurement of strontium-90 in the foodstuffs agricultural products etc
bull Measurement of gross beta activity in samplebull Self tests using built-in LED
ldquoPROGRESS-BETArdquo SCINTILLATION BETA SPECTROMETER
Physical characteristicsDetector bull Plastic scintillator Oslash70x10 mm
Sample bull Plate Oslash70 mmbull Weight up to 15 g
Energy range bull 02 divide 30 MeV
Minimum detectable activity of Sr-90 in a 10 g sample on a standard planchet Bqsamplebull In case of absence of K-40 in the sample 01 Bqbull In case the activity of K-40 till 5 Bqg 05 Bq
Electrical characteristics Interface bull USB
Mechanical characteristicsWeight bull No more 50 kg
Complete setBasic complete setbull Detector unit with plastic scintillator integrated
power supply amplifier ADC bull Lead shielding bull ldquoProgressrdquo software bull Сheck source for energetic calibration (Sr-90-Y-90) bull Planchet Oslash 70 mm (5 items) bull Sample dencification device bull Procedure manual for measurement of radio-
nuclidesrsquo activity using the scintillation beta spec-trometer ldquoProgressrdquo
Optional equipment and servicebull Personal computer and printer bull Calibrations for radionuclides not included in the
main library of radionuclides
Progress-Beta
Reference standards IEC 61562
SPC ldquoDozardquoRadiation monitoring equipment
66 67
bull Measurement of gamma activity in foodstuffs soil samples and others environmental objects
bull Identification of radionuclides in the sample bull Automatic correction for sample density bull Self-tests using built-in LED
ldquoPROGRESS-GAMMArdquoSCINTILLATION GAMMA SPECTROMETER
Physical characteristicsDetector bull NaI (Tl) Oslash63times63 mm
Validated measurement geometries bull Marinelli beakers (1 liter) Petri dishes (Oslash90 mm)
etc
Energy range bull 02 divide 30 MeV
Minimum detectable activity Bqsamplebull Cs-137 3 Bqbull Th-232 7 Bqbull Ra-226 8 Bq bull К-40 40 Bq
Electrical characteristics Interface bull USB
Mechanical characteristicsWeight bull No more 120 kg
Complete setBasic complete setbull Scintillation detector unit with NaI (Tl) detector
with integrated power supply amplifier and ADC bull Lead shielding 50 mm bull ldquoProgressrdquo software bull Сheck source for energy calibration (Cs-137 +
K-40)bull Marinelli beakers - 1 liter (5 items) bull Petri dishes Oslash 90 mm (5 items) bull Procedure manual for measurement of activity
of radionuclides using the scintillation gamma spectrometer ldquoProgressrdquo
Optional equipment and servicebull Kit for radon measurements including calibration
of ldquoIC-63rdquo geometry for counting the charcoal samples
bull Personal computer and printer bull Calibrations for user defined geometries bull Calibrations for radionuclides not included in the
main library of radionuclides
Progress-Gamma
Reference standards IEC 61563
ldquoPROGRESS-G(P)rdquoPORTABLE SCINTILLATION GAMMA SPECTROMETERbull Field measurements of gamma activity in environ-
mental objects without sampling (4π geometry)bull Laboratory measurement of gamma activity in
foodstuffs soil samples and others environmental objects
bull Identification of radionuclides in the sample bull Automatic correction for sample densitybull Tests using built-in LED
Physical charachteristicsDetector bull NaI (Tl) Oslash45times50 mmbull Lead shielding 20 mm
Validated measurement geometries bull Marinelli beakers (05 liter) Petri dishes (Oslash90 mm)
etc
Energy range bull 02 divide 30 MeV
Minimum detectable activity in 05-litre Marinelli beaker bull Cs-13710 Bqkgbull К-40100 Bqkgbull Ra-22618 Bqkg bull Th-23216 Bqkg
Minimum detectable activity in 30 min (4π geometry) bull Cs-137 2 Bqkgbull К-40 30 Bqkgbull Ra-226 4 Bqkg bull Th-232 3 Bqkg
Electrical characteristicsPower supply bull Rechargeable batterybull 220 V 50 Hz
Interface bull USB RS-232
Weight bull No more than 60 kg
Complete setBasic complete setbull Scinttillation detector unit with NaI(Tl) bull ldquoProgressrdquo softwarebull Сontrol unit ldquoSputnikrdquo for aquisition and analisys
of spectra with built-in memory for spectral databull Casebull Lead shielding (2 cm) for laboratory usebull 05-litre Marinelli beakers ndash 5 itemsbull Na-22 check sourcebull Power adapter BPS-01bull Operation manualbull Procedure manual for measurement of activity
of radionuclides using the scintillation gamma spectrometer ldquoProgressrdquo
Optional equipment and servicebull Kit for radon measurements with charcoalbull Built-in dose rate meterbull Additional memory (RAM) for storage of 64
spectrabull Additional power adapterbull Notebook and printer
Progress-Gamma
Reference standards IEC 61563
SPC ldquoDozardquoRadiation monitoring equipment
68 69
Physical characteristicsDetectorbull Scintillation detector ZnS (Oslash 60 mm)
Samplebull Thin sample - diameter up to 70 mm bull Preparation technique - electro-depositionbull Thick sample - diameter 70 mm weight
200300 mg bull Preparation technique - application of powders
(prepared by radiochemical concentration by water evaporation or by pounding of mineral samples) onto a planchet with the help of spirit
Energy rangebull 15 divide 8 MeV
Minimum detectable activitybull Thin samples no more than 910-3 Bqsamplebull Thick samples no more than 180 Bqkg
Mechanical characteristicsOverall dimensions weightbull 195times120times210 mm 34 kg
Complete setBasic complete setbull Alpha radiometer ldquoProgress-ARrdquobull Check source (uranium isotopes)
Set of accessoriesbull Procedure manual for measurements of radi-
oactivity using scintillation alpha radiometer ldquoProgress-ARrdquo
bull ldquoProgressrdquo software
ldquoProgress-ARrdquo
bull Measurement of gross activity of alpha emitting radionuclides in thin samples
bull Measurement of gross activity of alpha emitting radionuclides in thick samples
bull Measurement of activity deposited on aerosol filters
ldquoPROGRESS-ARrdquoALPHA RADIOMETER
Several fixed positions of the detector enable to perform measurements in various geometries and to estimate the content ofbull Cs-137 in the whole bodybull I-131 in thyroidbull Co-60 Cs-137 Mn-54 Cr-51 in lungsbull Database for storage of measurement data and
resultsbull Uncertainty calculations based on measurement
databull Self tests using built-in LED
ldquoPROGRESSrdquo WHOLE BODY COUNTER
Physical characteristicsDetectorbull scintillation detector NaI (Tl) Oslash63times63 mm
Energy rangebull 02 divide 28 MeV
Minimum detectable activitybull By Cs-137 in the whole body - 1200 Bqbull By I-131 in thyroid - 100 Bqbull By Co-60 Cs-137 Mn-54 Cr-51 in lungs - 200 Bq
Mechanical characteristicsWeight bull No more than 120 kg
Complete setBasic complete setbull Collimator with rotator and holderbull Detector with incorporated ADCbull Patient chair and table for collimatorbull Check source Na-22bull Procedure manual for lifetime measurement of
gamma-emitting radionuclidesrsquo activity in human body using the gamma-spectrometer of human radiation ldquoProgressrdquo
bull laquoProgressraquo software
Optional equipment and servicebull Program of internal radiation committed internal
radiation effective dose calculation by the stand-ard model
bull Background phantombull Personal computer and printer
Collimator with rotator and holder
SPC ldquoDozardquoRadiation monitoring equipment
70 71
bull Categorization of wastes for the purpose of fur-ther processing including wastes with unknown radionuclide composition
bull Measurements during the incoming waste inspec-tion (accepting for storage disposal)
bull Certification of unconditioned and conditioned wastes in closed containers without opening them (at nuclear plants or at facilities providing collection storage transportation conditioning processing temporal storage and final disposal of radioactive waste)
bull Activity measurement of extended objects in situ without opening the equipment
bull Activity measurement of extended objects after opening (for example assessment of tubes used for oil transportation)
MKG-01D ldquoSADOVNIKrdquoSPECTROMETRY SYSTEM
Physical charachteristicsDetectorbull Detector unit GEM (GMX) with HPGe detector and
multi-positioning cryostat CFG-PMOD4-7 with 7 litre Dewar
bull Dose rate probe BDMG-200
Energy range bull With GEM detector 004 divide 30 MeVbull With GMX detector 0005 divide 15 MeVbull Dose rate probe BDMG-200 ndash 005 divide 30 MeV
Measurement rangebull 110-7 divide 10 Svhbull Relative efficiency of detection (in photopeak) at
13325 MeV (Co-60) 10 divide 150
Electrical characteristicsPower supplybull 220 V 50 Hz
Interfacebull USB
Complete setBasic complete setbull Spectrometric detector unit GEM (GMX) with
HPGe detector and multi-positioning cryostat with 7 litre Dewar
bull Portable digital multichannel analyzer DigiDARTbull Dose rate probe BDMG-200bull Autonomous power supply unit with built-in
batterybull Industrial computer keyboardbull Laser range-finderbull Thermographic printerbull Web-camerabull Device equipped with stepper motor for position-
ing of the spectrometric detectorbull Calibration device with reference sources
(Am-241 Co-60 Ba-133 Eu-152) for energy calibration
bull Removable collimators with end capbull Measurement proceduresbull ldquoClasterrdquo software
bull Measurement of gross alpha activity of alpha-emitting radionuclides
bull Measurement of alpha-emitting radionuclides activity in thin-layer samples meeting alpha-spectrometry requirements
Physical characteristicsDetectorbull Silicon ion-implanted 450 mm2
bull Easy to decontaminate thin windowbull dead layer less than 015 μmbull Background count rate in the range 3 divide 9 MeVbull No more than 09 h-1cm-2 for 450 mm2 detector
Energy rangebull 2 divide 9 MeVbull Lower limit of measurement range (minimum
detectable activity) 01 Bqbull Background count rate no more than 100 counts
in 24 hours
Electrical characteristics Power supplybull 220 V 50 Hz
Interfacebull USB
Complete setBasic complete setbull Detector unit with vacuum measuring chamber
and vacuum control systembull Low noise vacuum pump (type 2FY-05B or
equivalent)bull Check sourcebull ldquoProgressrdquo softwarebull Vacuum tube
MKS-01A ldquoMULTIRAD-ASrdquoALPHA SPECTROMETER
SPC ldquoDozardquoRadiation monitoring equipment
72 73
UCRV-2AIRFLOW MONITOR
bull Monitor of the air flow through filter of centralized multichannel sampling system
bull Radiation monitoring system (RMS) integration for internal exposures determination
bull Volume and flow rate measurements of the air that have passed through a analytical filter
bull Bar-code for filter identificationbull Operation as either standalone unit or as a part of
the RMS
Physical characteristicsMeasurement range of air volume bull 001 divide 9999 m3
Operation temperature range bull minus 20 divide +50 ordmС
Electrical characteristicsPower supply bull 220 V 50 Hz
Interface bull RS-485
PVP-06PORTABLE AIR SAMPLER
Air Sampler PVP-06 is indispensable for monitoring the radiation situation where the concentration of radioactive aerosols in the air does not require a sta-tionary sampling equipment Sampling head PVP-06 provides easy change of filters and cartridges
Purposebull To monitor the concentration of radioactive aero-
sols in the air sites
Controlled aerosolsbull Alpha- and beta-active aerosolsbull Daughter products of decay of radon and thoronbull Iodine isotopes
Physical characteristicsTypes of filtersbull Aerosol AFA-RSP-20bull Iodine AFA SI-20
Flow rate bull 33∙10-4 ndash 233∙10-4 m3s (20 divide 140 l min)
Electrical characteristicsPower supply bull 220 V50 Hzbull The vehicle power supply 108 divide 145 Vbull Internal battery
Minimal working time on internal battery to recharge bull 8 hours
Power consumption (at a flow rate of 100 lmin) bull 40 VA
Environment characteristicsOperating temperature bull minus 10 divide +40 deg C
Maximum humidity bull 90
Pressure bull 860 to 1060 hPA
Noise generated by the pump bull lt 55 dBA at 1 m
Mechanical characteristicsDimensions weight bull 241 times 108 times 160 mm 28 kg
Case material bull Plastic
Complete setbull Air sampler PVP-06bull AC power adapterbull Filters AFA-RSP-20 - 100 pcsbull Packaging for filters - 40 pcsbull Casebull Operation manualbull Calibration certificate
Optional equimpient bull Kit for sampling sorption columns of activated
carbon Ř head of sorption columns with protective
covers Ř activated charcoal SKT-3 - 1 pkg (02 L) Ř charocoal samples SC-13 - 8 pcs
bull Car charger bull Tipod bull Shoulder strapbull Calibration stand bull Filters AFA SI-20 - 100 pcs
Consumablesbull Aerosol filters AFA RSP-20bull Iodine filters AFA SI-20
SPC ldquoDozardquoRadiation monitoring equipment
74 75
Calibration of gamma dose and dose rate meters
Calibration ofbull Ambient equivalent dose H(10) meters (Sv Svh)bull Personal equivalent dose Hp(10) meters (Sv Svh)bull Exposure dose X meters (R Rh)bull Two sources in irradiator bull Select source and collimator opening using
tumbler
UPG-P DESKTOP GAMMA BEAM IRRADIATOR
Physical characteristicsRange of reproduced dose rate bull 05 μSvh divide 10 mSvh (50 μRh divide 100 mRh)
Sources activities bull 6times106 6times108 Bq (02 20 mCi) Cs-137
Overall dimensions bull 1250times400times300 mm
Irradiator weight bull Not more than 37 kg
Calibration bench weight bull Not more than 15 kg
Reference standards IEC 60846 IEC 61526
Physical characteristicsDetectorbull Silicon
Measurement range EEC measurement bull Measurement range of radon EEC
10 divide 10bull106 Bqbullm-3
bull Measurement range of thoron EEC 05 divide 10bull104 Bqbullm-3
bull Air flow through the filter 100plusmn05 lmin
Concentration measurementbull Measurement range of radon-222 concentration
in air 10 divide 20bull106 cpsbull Measurement range of 216Po(ThA)
1bull10-3 divide 1bull102 cpsbull Air sampler flow rate
10plusmn02 lminbull Measurement range of radon-222 concentration
in water samples 6 divide 800 Bqbullkg-1
bull Measurement range of radon-222 flux from soil surface 20 divide 103 mBqsbullm2
bull Measurement range of radon-222 concentration with preliminary sampling of air using air sam-plers 20 divide 107 Bqbullm-3
bull Measurement range of radon-222 concentration in samples of soil air 103 divide 106 Bqbullm-3
Operation temperature range bull 1 divide 35 ordmC
Electrical characteristicsPower supply bull 80 VA
Mechanical characteristicsOverall dimensions weight bull 220times200times165 mm 36 kg
ldquoALPHARAD PLUSrdquoRADON THORON amp THEIR PROGENY MONITORbull Measurement of radon and thoron concentration
and effective equivalent concentration (EEC)bull In the airbull In the indoor air of residential public and industri-
al buildings and structuresbull Measurement of radon in drinking water sourcesbull Measurements of radon flux from the soil surface
at land plots allocated for construction of houses public buildings and industrial facilities
bull Measurements of radon concentration in soil air
Reference standards IEC 61577
SPC ldquoDozardquoRadiation monitoring equipment
76 77
UKPN-2M-D NEUTRON BEAM IRRADIATOR
Reference standards IEC 61005 61322
Calibration of neutron dose and dose rate meters
Calibration ofbull Ambient equivalent dose H(10) meters (Sv Svh)bull Personal equivalent dose Hp(10) meters (Sv Svh)bull Flux density of neutrons (cm-2∙s-1)bull Transfer container for temporary storage of
sources bull Red light signal of source working position
Physical carachteristicsRange of reproduced dose ratebull 20 divide 800 μSvh
Range of reproduced flux densitiesbull 10 divide 400 cm-2∙s-1
Type of a source in use bull Pu-Be
Activity of a source in usebull 24х1011 Bq (with density of 107 s-1)
Overall dimensions weight no morebull 3000x750x2000 mm 300 kg
Required room dimensionsbull not less than 7x3x3 m
Electrical characteristicsPower supply bull 220 V 50 Hz
Calibration of gamma dose and dose rate meters
Calibration ofbull Ambient equivalent dose H(10) meters (Sv Svh)bull Personal equivalent dose Hp(10) meters (Sv Svh)bull Exposure dose X meters (R Rh)bull Four sources in irradiator bull Select source and move to working position
return to storage position using special rodbull Transfer container for temporary storage of
sources bull Red light signal of source working position
UPGD-2M-DGAMMA BEAM IRRADIATOR
Physical characteristicsRange of reproduced dose rate bull 05 μSvh divide 50 mSvh (50 μRh divide 5 Rh)
Maximum activity of source bull 2times1011 Bq (50 Ci) Cs-137
Overall dimensionsbull Irradiator 800times500times500 mmbull Guide rails length 30 mbull Height 16 mbull Weight not more than 700 kgbull Required room dimensions not less than 7x3x3 m
Electrical characteristicsPower supply bull 220 V 50 Hz
UPGD-2M-D
Reference standards IEC 60846 IEC 61526 IEC 61066
SPC ldquoDozardquo
78 79
Contents
MEASURING UNITS
DBG-S11D wide range gamma area monitor 40
UDKS-100 gamma and X-ray area monitor 41
UDMN-100 neutron area monitor 41
ALARM UNITS
BAS-2 ldquoMICROrdquo external visual alarm 42
BZS-2 ldquoMicrordquo external audible alarm 42
Illuminated warning signs 43
ldquoImpulsrdquo external display unit 43
UIM-3D area monitor count rate meter 44
DKG-05D personal gamma dosimeter 46
DVS-02D gamma-neutron personal electronic dosimeter 47
DVGI-8D new pen-type personal ionization chamber dosimeters 48
DKG-02U ldquoARBITERrdquo wide range gamma-dosimeter 49
DKG-07D ldquoDROZDrdquo gamma-dosimeter 50
MKS-15D ldquoSNEGIRrdquo multi ndash purpose radiation survey meter 51
SRPS-05D gamma monitor 52
DOZA-TLD multipurpose TLD system 53
DKS-96 universal radiation survey meter 54
EXTERNAL PROBES ALPHA
Alpha BDZA-96 55
Alpha BDZA-96B 55
Alpha BDZA-96M 55
Alpha BDZA-96S 55
Alpha BDZA-96T 55
EXTERNAL PROBES BETA
Beta BDZB-96 56
Beta BDZB-99 56
Beta BDZB-96B 56
Beta BDZB-96S 56
EXTERNAL PROBES GAMMA
Gamma BDKS-96B 57
Gamma and beta BDKS-96S 57
Gamma BDMG-96 57
EXTERNAL PROBES GAMMA
Gamma-search BDVG-96 58
Gamma-search BDPG-96 58
ContentsRadiation monitoring systemldquoPELIKANrdquo Radiation monitoring system (RMS) 6
BDMG-101 high range gamma area monitor 10
DBG-S11D wide range gamma area monitor 11
BDRG-52 high range gamma area monitor for accident and post-accident conditions 12
UDGP-01 Liquid technological environments monitor 13
UDMN-100 neutron area monitor 14
UDKG-100 Wel Liquid gamma monitor 14
BOP-1M data processing and transmission unit 15
UDA-1AB particulate monitor 16
UDG-1B noble gas monitor 17
UDG-03D noble gas monitor 18
UDI-1B iodine monitor 19
UDGB-01 noble gasesH-3C-14 monitor 20
UDGP-01 steam generator leakage monitor 21
UPPVM air flow parameters monitor 22
ldquoIMPULSrdquo external display unit 23
BI-2 remote display amp alarm unit 24
BASBAS-1s external alarm 25
SKGAV stack monitor 26
RMS software 28
RMS workstation ndash operator console 29
Configurator software 29
RM RACK radiation monitoring rack 30
SRKS-01D criticality accident alarm system 32
ldquoATLANT-Mrdquo environmental radiation monitoring system 34
ldquoBREEZErdquo high-volume air sampler 35
ldquoGAMMA-SENSORrdquo gamma-survey system 36
Radiation monitoring equipmentAREA MONITOR ldquoFREGATrdquo 38
BPI-1D local display unit 39
80
Gamma-search BDPG-96M 58
Gamma BDKG-96 stainless steel casing for geologic applications well logging 59
EXTERNAL PROBES NEUTRON
Neutron BDMN-96 59
Neutron-search BDKN-96 59
RZB-05D Hand-foot-clothing monitor 60
RZBA-04-04M whole body contamination monitor 61
RZA-05D alpha hand-monitor 62
UMF-2000 low level alpha- beta- counter 63
DRK dose area product meter 64
ldquoPROGRESS-BETArdquo scintillation beta spectrometer 65
ldquoPROGRESS-GAMMArdquo scintillation gamma spectrometer 66
ldquoPROGRESS-G(P)rdquo portable scintillation gamma spectrometer 67
ldquoPROGRESS-ARrdquo alpha radiometer 68
ldquoPROGRESSrdquo whole body counter 69
MKG-01D ldquoSADOVNIKrdquo spectrometry system 70
MKS-01A ldquoMULTIRAD-ASrdquo alpha spectrometer 71
UCRV-2 airflow monitor 72
PVP-06 portable air sampler 73
ldquoALPHARAD PLUSrdquo radon thoron amp their progeny monitor 74
UPG-P desktop gamma beam irradiator 75
UPGD-2M-D gamma beam irradiator 76
UKPN-2M-D neutron beam irradiator 77
Radiation monitoring system SPC ldquoDozardquo
10 11
bull Continuous automatic monitoring of the ambient dose equivalent rate
bull Нigh temperature range (up to 120 degC)
BDMG-101 HIGH RANGE GAMMA AREA MONITOR
Physical characteristicsbull detector ndash ionization chambers
Measurement rangebull MIC-1 5∙10-5 divide 200 Svhbull MIC-2 5∙10-4 divide 1000 Svhbull MIC-3 1∙10-5 divide 100 Gyhbull MIC-4 5∙10-3 divide 10000 Gyh
Energy rangebull 005 divide 30 MeV
temperature rangebull ionization chamber module MIC-1
minus 30 divide +120 degCbull electrometric module MIC-2 MIC-3 MIC-4 ME
minus 30 divide +60 degC
Electrical characteristicsbull interfaces RS-485bull cable length between MIC and ME up to 30 m
Mechanical characteristicsbull Protection index IP 65
Overall dimensions weightbull ME Oslash105times293 mm 23 kgbull MIC-1 Oslash85times206 mm 12 kgbull MIC-2 Oslash45times156 mm 03 kgbull MIC-3 Oslash136times226 mm 09 kgbull MIC-4 Oslash35times92 mm 02 kg
BOP-1M
Reference standards Nuclear IEC 60846 IEC 60532
DBG-S11D WIDE RANGE GAMMA AREA MONITOR
Continuous automatic monitoring of the ambient dose equivalent rate
Physical characteristicsbull Detector ndash GM counters
Measurement rangebull DBG-S11D 01 μSvh divide 10 mSvhbull DBG-S11D-01 01 μSvh divide 10 Svhbull DBG-S11D-02 01 μSvh divide 100 Svh
Energy rangebull 005 divide 30 MeV
Temperature range bull minus 40 divide +50 ordmC
Electrical characteristicsbull Interfaces RS-485 USB
Mechanical characteristicsbull Protection index IP 68bull Paint decontaminable
Overall dimensions weightbull DBG-S11D Oslash 68times141 mm 065 kg bull DBG-S11D-01 Oslash 68times179 mm 07 kgbull DBG-S11D-02 Oslash 68times179 mm 07 kg
Versionsbull DBG-S11Dbull DBG-S11D-01bull DBG-S11D-02
BOP-1M
Reference standards Nuclear IEC 60532
Versionsbull stainless steel 100 cm2 ionization chamber
module (MIC-1) and electrometric module (ME)bull stainless steel 20 cm2 ionization chamber module
(MIC-2) and electrometric module (ME)bull duralumin 500 cm2 ionization chamber module
(MIC-3) and electrometric module (ME)bull titanium 2 cm2 ionization chamber module
(MIC-4) and electrometric module (ME)
Radiation monitoring system SPC ldquoDozardquo
12 13Reference standards EMC IEC 61010 IEC 61000-6-2 Seismic IEC 60980
bull Continuous automatic monitoring of the ab-sorbed dose rate
bull Monitoring inside containmentbull Delivery assembled detector and communication
linebull Communication line include inter wall protective
tubebull Hermetic communication line filled dry nitrogen
Physical characteristicsbull detector - stainless steel ionization chamber
Measurement range bull 10-3 divide 105 Gyh
Energy range bull 006 divide 30 MeV
Temperature range bull detector
0 divide 207 ordmC continuous
250 ordmC during 1 hour bull electrometric module 0 divide +60 ordmC
Detector operating pressure bull 07 МPa
Electrical characteristicsbull Interfaces RS-485bull detector-electrometric module cable length up
to 70 m
BDRG-52 HIGH RANGE GAMMA AREA MONITOR FOR ACCIDENT AND POST-ACCIDENT CONDITIONS
Ionization chamber
Mechanical characteristicsProtection index bull detector - IP 65bull electrometric module - IP 23bull Paint stainless steel
Overall dimensions weight bull detecting unit Oslash50х220 mm 3 kgbull inter wall protective tube Oslash 159 length (by order)
1200 ndash 1600 mm 60 kgbull electrometric module 420x420x120 mm 8 kg
Reference standards Nuclear IEC 60951 EMC IEC 61010 IEC 61000-6-2 Seismic IEC 60980
Continuous monitoring of technological environ-ments liquid couples sludges etc bull On line gamma spectrometry
Physical characteristicsbull Detector ndash scintillator CsI NaI
Measurement range bull Gamma-activity 10bull104 divide 20bull108 Bqm3
Energy range bull gamma 005 divide 15 MeV
Temperature range bull minus 10 divide +80 ordmС
UDGP-01 LIQUID TECHNOLOGICAL ENVIRONMENTS MONITOR
Electrical characteristicsbull Interfaces RS-232 RS-485 Ethernetbull programmable relay output (SPDT relay)
Mechanical characteristicsbull Protection index IP 65bull Paint decontaminable
Overall dimensions weight bull Detector unit
CsIOslash 60x360 mm17 kg NaIOslash 35x750 mm26 kg
bull Data processing and transmission unit BOP-1sp 280x220x114mm 43 kg
Alarmbull Sound alarm 80 divide 100 dBA at distance 1 mbull Visual alarm green yellow redbull Connection of the external alarm unit of ldquoBASrdquo
type
Radiation monitoring system SPC ldquoDozardquo
14 15
BOP-1M DATA PROCESSING AND TRANSMISSION UNIT
bull Processing of data incoming from detecting blocks UDMN-100 DBG-S11D UDKG-100 BDMG-101 BDRG-52
bull Data transmission to the network bull Data transmission to the mobile computer bull Storage of thresholds values and parameters of
detecting blocksbull Power supply and diagnostics of detecting blocks bull Generation of the alarm signals of the excess of
preset thresholdsbull Data backup in the non-volatile memory
Physical characteristicsbull Quantity of joined detecting blocks and alarm
units ndash up to 20bull Temperature range minus 40 divide +50 ordmC
Electrical characteristicsbull Power supply 85 divide 260 V 47 divide 440 Hzbull Interfaces RS-232 RS-485 Ethernet bull programmable relay output (SPDT relay)
Mechanical characteristicsbull Protection index IP 65 bull Paint decontaminable
Overall dimensions weightbull 298times220times114 mm 5 kg
Reference standards EMC IEC 61010 IEC 61000-6-2 Seismic IEC 60980
Continuous automatic monitoring of the neutron-radiations ambient dose equivalent ratebull Spherical polyethylene moderator Oslash 239 mm
UDMN-100 NEUTRON AREA MONITOR
Physical characteristicsbull detector ndash scintillator ZnS(Ag) Li-6
Measurement range bull 01 μSvh divide 01 Svh
Energy range bull 0025 eV divide 100 MeV
Temperature range bull minus 45 divide +50 ordmC
Electrical characteristicsbull Interfaces RS-485
Reference standards Nuclear IEC 61005 IEC 61322 EMC IEC 61010 IEC 61000-6-2 Seismic IEC 60980
UDKG-100WEL LIQUID GAMMA MONITOR
Mechanical characteristicsbull Protection index IP 65bull Paint decontaminable
Overall dimensions weight bull 428times258times347 mm 115 kg
Continuous automatic monitoring of the gamma radiation flux Operation in the rocks ore liquid media and sludge
Physical characteristics bull detector ndash NaI (Tl) Oslash 18x30 mm
Measurement range bull 40 divide 8104 s-1cm-2
Energy range bull 01divide 30 MeV
Temperature rangebull minus 40 divide +50 degC
Electrical characteristics bull Interfaces RS-485
Mechanical characteristics bull Protection index
Ř BDKG-100 IP 68 Ř Interface block BS-16 IP 65
bull Paint stainless steel bull Overall dimensions weight
Ř Detector unit BDKG-100 Oslash 38times530 mm 3 kg Ř Interface block BS-16 176times80times64 07 kg
Radiation monitoring system SPC ldquoDozardquo
16 17
UDG-1B NOBLE GAS MONITOR
Continuous automatic monitoring of the beta-emit-ting radioactive gases concentration in the working air and in the air in ventilation ducts and stacksbull Gamma background compensation bull Audible and visual alarm signals of the excess of
preset thresholds bull Periodic calibration by means of standard beta-
source
Physical characteristicsbull Silicon detectors (2 pcs for measurement and for
background compensation)bull Air flow rate 10 divide 100 lminbull Operation temperature range minus 10 divide +50 ordmС
Measurement range bull 104 divide 6109 Bqm3
Energy range bull 008 divide 30 MeV
Electrical characteristicsbull Power supply 85 divide 260 V 47 divide 440 Hzbull Interfaces RS-232 2timesRS-485 Ethernetbull programmable relay output (SPDT relay)bull Analog output 4-20 mA (optional)
Mechanical characteristicsbull Protection index IP 65bull Paint decontaminable
Overall dimensions weight bull Stationary version 395times240times304 mm 295 kgbull Mobile version with pump unit BN-1
395times468times950 mm 543 kg
Alarmbull Sound alarm 80 divide 100 dBA at distance 1 mbull Visual alarm green yellow red
Mobile version with pump unit BN-1
Stationary version
Reference standards Nuclear IEC 60761 IEC 62302 EMC IEC 61010 IEC 61000-6-2 Seismic IEC 60980
bull Connection of the external alarm unit ldquoBASrdquo type
Versionsbull Stationary versionbull Stationary version with pump unit BN-1bull Mobile version with pump unit BN-1
UDA-1AB PARTICULATE MONITOR
Stationary version
Continuous automatic monitoring of the alpha- and beta- radioactive aerosol concentration in the work-ing air and in the air in ventilation ducts and stacksbull Radon toron progenies and gamma background
compensation bull On line alpha spectrometrybull Audible and visual alarm signals of the excess of
preset thresholds bull Control of electromagnetic valves when operating
with the external air sampling linebull Control of pump unit bull Periodic calibration by means of standard beta-
and alpha-sources
Physical characteristicsbull Silicon specrometric detectors (2 pcs for measure-
ment and for background compensation)bull Filter tape types LFAS FSLWbull Tape consumption (when continuous operation)
10 m50 daysbull Air flow rate 10 divide 100 lmin bull Operation temperature range minus 10 divide +50 ordmС
Measurement range bull Alpha 10-2 divide 2105 Bqm3 bull Beta 10-1 divide 106 Bqm3
Energy range bull Alpha 30 divide 90 MeV bull Beta 005 divide 30 MeV
Electrical characteristicsbull Power supply 85 divide 260 V 47 divide 440 Hzbull Interfaces RS-232 2timesRS-485 Ethernet bull Programmable relay output (SPDT relay)bull Analog output 4-20 mA (optional)
Mechanical characteristicsbull Protection index IP 65bull Paint decontaminable
Overall dimensions weight bull Stationary version 389times260times304 mm 156 kg bull Mobile version with pump unit BN-1
389times468times950 mm 384 kg
Alarmbull Sound alarm 80 divide 100 dBA at distance 1 mbull Visual alarm green yellow redbull Connection of the external alarm unit ldquoBASrdquo type
Versionsbull Stationary versionbull Stationary version with pump unit BN-1bull Mobile version with pump unit BN-1
Reference standards Nuclear IEC 60761 IEC 61172 EMC IEC 61010 IEC 61000-6-2 Seismic IEC 60980
Mobile version with pump unit BN-1
Radiation monitoring system SPC ldquoDozardquo
18 19
Physical characteristicsbull Scintillation detectors CsI(Tl) (2 pcs for measure-
ment and for background compensation)bull Cartridge activated charcoal
Measurement range bull 37 divide 37106 Bqm3
Energy range bull 006 divide 30 MeVbull Air flow rate 20 divide 40 lminbull Operation temperature range minus 10 divide +50 ordmС
Electrical characteristicsbull Power supply 85 divide 260 V 47 divide 440 Hzbull Interfaces RS-232 2timesRS-485 Ethernetbull Programmable relay output (SPDT relay)bull Analog output 4-20 mA (optional)
Mechanical characteristicsbull Protection index IP 65bull Paint decontaminable
Overall dimensions weight bull Stationary version 448times323times479 mm 35 kgbull Mobile version with pump unit BN-1
448times468times950 mm 578 kg
Reference standards Nuclear IEC 60761 IEC 61171 EMC IEC 61010 IEC 61000-6-2 Seismic IEC 60980
Alarmbull Sound alarm 80 divide 100 dBA at distance 1 mbull Visual alarm green yellow redbull Connection of the external alarm unit of ldquoBASrdquo
type
Versionsbull Stationary versionbull Stationary version with pump unit BN-1bull Mobile version with pump unit BN-1
Сontinuous automatic monitoring radioiodine concentration in the air at working places and in ventilation ducts and stacksbull Measurement of volumetric activity of radionu-
clides I-131 I-132 I-133 I-135 in the airbull On line gamma spectrometrybull Gamma background compensation bull Performance self-test by means of Am-241 check
source implanted into the detectorbull Audible and visual alarm signals of the excess of
preset thresholdsbull Periodic calibration by means of standard source
UDI-1B IODINE MONITOR
Physical characteristicsbull Silicon detector 2 pcs (for measurement and for
background rejection)bull Air flow rate 10 divide 100 lminbull Operation temperature range minus 10 divide +50 ordmС
Measurement range bull 104 divide 11010 Bqm3
Energy rangebull 006 divide 30 MeV
Electrical characteristicsbull Power supply 120 Vbull Interface RS-485
Mechanical characteristicsbull Protection index IP 65bull Paint decontaminable
Overall dimensions weight bull 474х246х243 mm 295 kg
UDG-03D NOBLE GAS MONITOR
Measurement of volumetric activity of beta-emitting radioactive gases (argon krypton xenon) adapted to the measurement of the rapidly changing volume activity in various technological processesbull Gamma background compensationbull Periodic calibration by means of standard beta-
source
Reference standards Nuclear IEC 60761 IEC 62302 EMC IEC 61010 IEC 61000-6-2 Seismic IEC 60980
Radiation monitoring system SPC ldquoDozardquo
20 21
Continuous automatic monitoring of steam genera-tor primary to secondary leakagebull On line gamma spectrometrybull N-16 monitoringbull Performance self-test by means of Am-241 check
source implanted into the detectorbull Audible and visual alarm signals of the excess of
preset thresholds
Physical characteristics
UDGP-01 STEAM GENERATOR LEAKAGE MONITOR
bull detector ndash scintillator CsI Oslash 40х100 mm
Measurement range bull High energy gamma-activity (N-16)
15bull103 divide 20bull108 Bqm3
bull General gamma-activity 10bull104 divide 20bull108 Bqm3
Energy range bull General gamma 005 divide 15 MeV bull in integral spectral band of energy
5000 divide 7200 keV bull temperature range minus 10 divide +80 ordmС
BOP-1SP
Electrical characteristicsbull Power supply 85 divide 260 V 47 divide 440 Hzbull Interfaces RS-232 RS-485 Ethernetbull programmable relay output (SPDT relay)
Mechanical characteristicsbull Protection index IP 65bull Paint decontaminable
Overall dimensions weight bull Detector unit Oslash 60x360 mm17 kgbull Data processing and transmission unit BOP-1sp
280x220x114mm 43 kgbull Collimator Oslash 350x455 mm 150 kg
Alarmbull Sound alarm 80 divide 100 dBA at distance 1 mbull Visual alarm green yellow redbull Connection of the external alarm unit of ldquoBASrdquo
type
Reference standards Nuclear IEC 61453 EMC IEC 61010 IEC 61000-6-2 Seismic IEC 60980Reference standards Nuclear IEC 60761 IEC 60710 IEC 60951-2 EMC IEC 61010 IEC 61000-6-2 Seismic IEC 60980
Ionization chambe 10 liters
UDGB-01T1
Physical characteristicsbull Detectors - stainless steel ionization chambersbull Air flow rate 10 divide 100 lminbull Operation temperature range minus 10 divide +50 ordmС
Volumes of ionization chambers bull UDGB-01T UDGB - 01T1 100 litersbull UDGB-01T2 01 liter
Measurement range (Kr-85) bull UDGB-01T UDGB-01T1 10104 divide 50109 Bqm3
bull UDGB-01T2 109 divide 501014 Bqm3
Measurement range (H-3) bull UDGB-01T UDGB-01T1 50104 divide 50109 Bqm3
bull UDGB-01T2 50109 divide 501014 Bqm3
Electrical characteristicsbull Power supply 85 divide 260 V 47 divide 440 Hzbull Interfaces RS-232 2timesRS-485 Ethernetbull Programmable relay output (SPDT relay)bull Analog output 4-20 mA (optional)
Mechanical characteristicsbull Protection index IP 23bull Paint decontaminable
Continuous automatic monitoring of the beta-emitting radioactive gases including tritium and carbon-14 concentration in the air at working places and in ventilation ducts and stacksbull Audible and visual alarm signals of the excess of
preset thresholds bull Monitoring of the noble gase activity in gaseous
effluents and ventilation air for accident and post-accident conditions
Overall dimensions weight bull UDGB-01T 381times343times716 mm 30 kgbull UDGB-01T1 260times320times175 mm 125 kgbull Ionization chamber 100 liters Oslash 250times600 mm
6 kgbull UDGB - 01T2 381times343times716 mm 27 kg
Alarmbull Sound alarm 80 divide 100 dBA at distance 1 mbull Visual alarm green yellow redbull Connection of the external alarm unit ldquoBASrdquo type
Versionsbull UDGB-01T - with built-in ionization chamber
100 litersbull UDGB-01T2 - with built-in ionization chamber
01 literbull UDGB-01T1 - with remote ionization chamber
100 liters
UDGB-01NOBLE GASESH-3C-14 MONITOR
Radiation monitoring system SPC ldquoDozardquo
22 23
Physical characteristicsLength of communication cablebull up to 1200 m
Character height bull ldquoImpuls-910-Rrdquo 100 mmbull ldquoImpuls-915-D4Srdquo 150 mmbull ldquoImpuls-927-D4Srdquo 270 mm
Operating temperature rangebull ldquoImpuls-910-Rrdquo 0 divide +50 ordmCbull ldquoImpuls-915-D4Srdquo ldquo-927-D4Srdquo minus 40 divide +50 ordmC
Electrical characteristicsbull Power supply 220 V 50 Hz
Mechanical characteristicsProtection index bull ldquoImpuls-910-R IP 44bull ldquoImpuls -915-D4Srdquo ldquo-927-D4Srdquo IP 65
Overall dimensions weight bull ldquoImpuls-910-Rrdquo 400times160times60 mm 3 kgbull ldquoImpuls -915-D4Srdquo 815times250times80 mm 5 kgbull ldquoImpuls -927-D4Srdquo 1250times330times80 mm 5 kg
ldquoIMPULSrdquoEXTERNAL DISPLAY UNIT
Display of data received from monitors of RMS
External display unit ldquoImpuls-910-Rrdquo
Reference standards EMC IEC 61010 IEC 61000-6-2 Seismic IEC 60980
Continuous monitoring of the flow rate temperature and humidity of the gas flowbull Definition of air volume flow rate in stacks taking
into account temperature and humidity of the air
UPPVM AIR FLOW PARAMETERS MONITOR
Physical characteristicsMeasurement range bull air flow velocity 1 divide 20 msbull air temperature 0 divide +80 ordmСbull air humidity 10 divide 95
Electrical characteristicsbull Power supply 220 V 50 Hz bull Interfaces RS-232 Ethernet
Mechanical characteristicsProtection index bull BSPP-1st BSPP-1tv BOP-1s IP 65bull PP-st IPTV IP 54bull Paint decontaminable
Overall dimensions weight bull air velocity probe PP-st 60times38times136 mm 015 kgbull Interface block BSPP-1st 125times155times73 mm 07 kgbull air temperature and relative humidity probe
IPTV-056-A 333times100times60 mm 07 kgbull Interface block BSPP-1tv 125times155times73 mm 07 kgbull Data processing and transmission unit BOP-1s
280x233x111 mm 8 kg
Reference standards Nuclear ISO 2889 EMC IEC 61010 IEC 61000-6-2 Seismic IEC 60980
BOP-1S
Radiation monitoring system SPC ldquoDozardquo
24 25
BASBAS-1S EXTERNAL ALARM
Generation of audible and visual signals of the excess of preset thresholds RMS monitorsbull Audible alarm 80 divide 100 dBA at distance 1 mbull Visual alarm green yellow red
Distance from RMS monitorbull BAS up to 20 mbull BAS-1s up to 1200 m
Power supply bull 220 V 50 Hz
Overall dimensions weight bull BAS 145times108times460 mm 18 kg bull BAS-1s 166times109times466 mm 18 kg
Reference standards EMC IEC 61010 IEC 61000-6-2 Seismic IEC 60980
Physical characteristicsLength of communication cablebull up to 1200 m
Displayed page size bull 4 lines of 20 characters
Volume of loaded information bull 10 pages
Change of pagesbull programmed or by pressing a button
Operating temperature rangebull minus 40 divide +50 ordmC
Electrical characteristicsbull Power supply 9 divide 18 VDCbull Interfaces RS-485
Mechanical characteristicsbull Protection index IP 65bull Overall dimensions weight 222times164times73 mm
40 kg
BI-2 REMOTE DISPLAY amp ALARM UNIT
bull Display of data received from monitors of RMSbull Audible and visual alarms on exceeding preset
thresholds of the RMS equipment bull Individual threshold setting for each measure-
ment channelbull Audible alarm 80 divide 100 dB at a distance of 1 m bull Visual alarm red yellow green
Reference standards EMC IEC 61010 IEC 61000-6-2 Seismic IEC 60980
Radiation monitoring system SPC ldquoDozardquo
2726
Electrical characteristicsbull Power supply 220 V 50 Hz bull Interfaces RS-232 RS-485 Ethernetbull programmable relay output (SPDT relay)
Alarmbull Sound alarm 80 divide 100 dBA at distance 1 mbull Visual alarm green yellow redbull Connection of the external alarm unit ldquoBASrdquo type
Related monitors and equipmentsbull UDA-1AB particulate monitorbull UDG-1B noble gas monitorbull UDI-1B iodine monitorbull UPPVM air flow parameters monitorbull Sampling and sample separation rack
Air flow parameters monitor rack
Reference standards Nuclear IEC 60761 IEC 61171 IEC 61172 IEC 62302 ISO 2889 EMC IEC 61010 IEC 61000-6-2 Seismic IEC 60980
Sampling and sample separation rack
Continuous monitoring of radioactivity in gaseous effluentsbull Automatic monitoring of the alpha- and beta-
radioactive aerosol noble gas and radioiodine concentrations in the air in ventilation ducts and stacks
bull Monitoring of the flow rate temperature and humidity of the gas flow
bull Separation of gaseous effluent into targeted fractions by means of a two-stage filter
bull Reversion of gas after analysis to the ventilation system
Physical characteristics
Particulate (UDA-1AB)bull Silicon specrometric detectors (2 pcs for measure-
ment and for gamma-background compensation) bull Filter tape types LFAS FSLWbull Tape consumption (when continuous operation)
10 m50 days
Measurement range bull Alpha 10-2 divide 2105 Bqm3 bull Beta 10-1 divide 106 Bqm3
Energy range bull Alpha 30 divide 90 MeV bull Beta 005 divide 30 MeV
Noble gas (UDG-1B)bull silicon detectors (2 pcs for measurement and for
gamma-background compensation)
Measurement range bull 104 divide 6109 Bqm3
Energy range bull 008 divide 30 MeV
Iodine (UDI-1B)bull scintillation detectors CsI(Tl) (2 pcs for measure-
ment and for background compensation)
SKGAV STACK MONITOR
Particulate noble gas and iodine monitors rack
Measurement range bull 37 divide 37105 Bqm3
Energy range bull 015 divide 30 MeV
Air flow parameters (UPPVM)Measurement range bull air flow velocity 1 divide 20 msbull air temperature 0 divide +80 ordmСbull air humidity 10 divide 95
Radiation monitoring system SPC ldquoDozardquo
28 29
CONFIGURATOR SOFTWAREMaintenance and set-up softwarebull Set-up and verify RMS monitorsbull Control testing adjustment and repair of RMS
monitorsbull Monitors measurement results archive receive
and View bull Communication through RS-232
RMS WORKSTATION ndash OPERATOR CONSOLEOrganization of interaction of the RMS Server and Monitors
Single monitor console includes vandal-proof key-board amp UPS
Reference standard IEC 61559-1 IEC 61559-2
RMS SOFTWAREData acquisition storing and visual representation RMS monitors measurement resultsbull Ethernet IEEE 8023 networkbull Clientserver architecturebull TCPIP protocolbull Oracle based Data Basebull Supremal by means InSat MasterSCADA
Radiation monitoring system SPC ldquoDozardquo
30 31
Delivery setComposition and modification depend on the tasks to be solved using the RM Rack
The rack which is an integral part of RM Rack accommodatesbull Monitors UDA-1AB UDG-1B UDG-03D UDI-1B
UDGB-01Tbull DBG-S11D Wide range gamma area monitor
BDMG-101 High range gamma area monitor UDMN-100 Neutron area monitor BDRG-52R High range gamma area monitor
bull BI-2 Remote display amp alarm unitbull Pump unit BN-01bull Data processing and transmission unit BOP-1Mbull External alarm BAS or BAS-1sbull Equipment of sampling line (flow meters ball
valves filter holder piping solenoid valve)bull Switchboard (intended for switching of all equip-
ment and transfer of data to the upper level via the unified communication channel)
RM RACK RADIATION MONITORING RACK
The radiation monitoring rack (RM Rack) is designed for continuous monitoring of radiation parameters in premises and technological systems at nuclear facil-ities RM Rack can be used as a structural element of the lower-level of RMS at nuclear power plants and other nuclear facilities that involved in obtaining processing use and storage of radioactive materials
FeaturesContinuous automatic monitoring of the alpha- and beta- radioactive aerosol beta-emitting radioactive gases and radioiodine concentrations in the working air and in the air in stacks and others radiation parameters in the facilities
The stand providesbull Primary processing storage and transmission of
measured and related data into the information channel based on the Ethernet IEEE 8023 inter-face (TCPIP protocol)
bull Transfer of required data to the location where the equipment is installed via technological channels based on RS-232 interface
bull Generation of audible and visual warning alarm signals when the preset thresholds are exceeded
bull Display of received data on the LCD
Radiation monitoring system SPC ldquoDozardquo
32 33Reference standards IEC 60860 ANSIANS-83 ISO 7753
Purposebull Detection and recording of criticality accident
(CA) by measuring the absorbed dose rate of gamma-neutron radiation in the premises of monitored object its comparison with a threshold value and generation of audible and visual signals
bull Automatic collection processing storage and display of measurement data and related infor-mation as visual and graphical representation for operators of nuclear safety service
Functions of the systembull Detection and recording of CA events by con-
tinuous measurement of absorbed dose rate of gamma radiation comparison of measured values with preset thresholds generation of signals to activate the alarm
bull Activation of audible visual alarmbull In the event of CA turning on warning signals
ldquoDO NOT ENTERrdquo at illuminated information pan-els placed at the entrances to the controlled area
Featuresbull Data can be transferred to external data commu-
nication channel using RS-485 interface (DiBus data exchange protocol)
bull Automatic self-testing of detection units BR-04D with display of information about the type of fault
bull Possibility for connecting additional a detection and alarm units
bull Ability to function in general regardless of the functioning of components within the agreed scope of nuclear safety tasks
bull Radiation hardness up to 100 Gy
SRKS-01DCRITICALITY ACCIDENT ALARM SYSTEM
Features of softwarebull Collection of information via RS-485 network
displaying it on the PC monitor transmission to remote users archiving and storage
bull Status monitoring and display of values measured by BR-04D and DBG-S11D in locations as per layout of premises
bull Access to archived data with possibility to gener-ate reports for periods determined by operator
bull Maintenance and archiving of a log of dosimetric measurements data and events along with their time stamps
bull Possibility to transfer data to external users via Ethernet network for integrating of CA into higher level systems
Basic complete setLower level bull Control unit with power supplybull BR-04D detection unitsbull BZS-01D audible alarm unitsbull BSS-01D visual alarm unitsbull SIT-01D illuminated warning signsbull PBZ panels for muting audible alarmbull Network communication module
Additional lower layer devicesbull DBG-S11D wide range gamma area monitor
Upper layer bull CDP central display panelbull Service workstation
RS-485
RS-485
RS-4
85
Audible alarm units BZS-01D
Illuminated warning signs SIT-01D
Detection units BR-04D
Network communication
moduleDBG-S11D wide range gamma area monitor
Panels for muting audible alarm
Control unit with power supply
Visual alarm units BSS-01D
RS-485
RS-485
RS-4
85
Audible alarm units BZS-01D
Illuminated warning signs SIT-01D
Detection units BR-04D
Network communication
moduleDBG-S11D wide range gamma area monitor
Panels for muting audible alarm
Control unit with pow-er supply
Visual alarm units BSS-01D
RS-485
RS-4
85
Audible alarm units BZS-01D
Illuminated warning signs SIT-01D
Detection units BR-04D
Network communication
moduleDBG-S11D wide range gamma area monitor
Panels for muting audible alarm
Control unit with power supply
Visual alarm units BSS-01D
RS-485
RS-485
RS-4
85
Audible alarm units BZS-01D
Illuminated warning signs SIT-01D
Detection units BR-04D
Network communication
moduleDBG-S11D wide range gamma area monitor
Panels for muting audible alarm
Control unit with power supply
Visual alarm units BSS-01D
Ethernet
Central display panel Service workstation
RS-485
RS-485
RS-4
85
BZS-01D audible alarm units
SIT-01D illuminated warning signs
BR-04D detection units
Network communication
moduleDBG-S11D wide range gamma area monitor
PBZ panels for muting audible alarm
Control unit with power supply
BSS-01D visual alarm units
Radiation monitoring system SPC ldquoDozardquo
34 35
ldquoBREEZErdquoHIGH-VOLUME AIR SAMPLER
Physical characteristicsbull Measurement range of air flow rate
250 divide 1200 m3hbull Continuous operation time not less than 24 h
Filter materialsbull High-purity glass fiberbull Pure quartz or cellulosebull Filter fabric FPP-15-15
Electrical characteristicsPower supply bull 220380 V 50 Hz
Interfaces bull RS-485bull Ethernetbull GSMGPRS (option)
Environmental characteristicsTemperature range bull minus 40 divide + 40 ordmC
Relative humidity limit at 35 ordmC bull 95
Atmospheric pressure range bull 840 divide 1067 kPa
Versionsbull Standalone unit bull Part of Environmental Radiation Monitoring
System (ERMS)
Type of detection unitsbull Beta block BDZB-100Lbull DBG-S11D wide range gamma area monitorbull Scintillation spectrometric block
The motor of Air Sampler is controlled by an electronic flow sensor that detects changes in the operators pre-set flow rate caused by changes in temperature barometric pressure and pressure drop due to dust loading on filter media It compensates for these changes by adjusting the motor speed to maintain the pre-set flow ratebull Measurement of parameters of ionizing radiation bull Standalone mode of operation or as the part
of Environmental Radiation Monitoring System (ERMS)
Purposebull Environmental Radiation Monitoring System
(ERMS) in the control and buffer areas of the radia-tion and nuclear facilities
Referencesbull Since the year 2000 the system is successfully
operating the ERMSs at 8 Russian nuclear power plants (about 180 monitoring stations)
bull Since the year 2005 the ERMS is operating in the Moscow (about 40 monitoring stations)
bull Since the year 2005 the regional ERMS is under operation in several Russian Federation regions
Basic complete setMonitoring stations bull Data processing and transmission unit BOP-1TA bull Gamma area monitor DBG-S11D
Central data processing station (CDPS)bull Data processing and transmission unit BOP-1TAbull Server
By requestbull Emergency Response and Crisis Management
Centers for enterprisesbull Regional Emergency Response and Crisis Manage-
ment Centersbull rdquoBreezerdquo High-Volume Air Samplerbull Mobile lab with gamma-survey system rdquoGammandash
sensorrdquo
ldquoATLANT-MrdquoENVIRONMENTAL RADIATION MONITORING SYSTEM
Monitoring system for the continuous radiation monitoring of territories and facilities with the data transmission GSMGPRS network
Data transmission bull GSMGPRS
Power supply bull 220 V 50 Hz
Continuous autonomous operation (at 20 ordmC)bull From built-in battery not less than 5 hoursbull From external battery not less than 24 hours
Operation temperature bull Minus 40 divide +50 ordmC
Operation humidity bull Up to 98
Protection bull IP65
Reference standards Nuclear IEC 61017-11991 IEC 61017-21994
36
Radiation Monitoring Equipment
bull Localization of radioactive contaminationsbull Database with dose rate contaminations
spectra measurement date amp time coordi-nates
bull Work as part of mobile laboratory or as part of Environmental Radiation Monitoring System with real-time data transfer
Physical characteristicsDetector bull Scintillation NaI (Tl) GM counters
Measurement rangebull 01 ndash 107 μSvh
Energy range bull 005 ndash 3 MeV
Operation temperature range bull minus 10 divide +50 ordmС
Electrical characteristics bull Power supply 220 V 50 Hz
ldquoGAMMAndashSENSORrdquoGAMMA-SURVEY SYSTEM
SPC ldquoDozardquoRadiation monitoring equipment
38 39
AREA MONITOR ldquoFREGATrdquoArea Monitor ldquoFregatrdquo is designed for building rela-tively simple and inexpensive radiation monitoring systems at such facilities as radionuclide sources storage areas isotope products warehouses nuclear medicine departments PET centers calibration laboratories where sources of ionizing radiation are used etc
Small scale automated radiation monitoring systems built with ldquoFregatrdquo components featuring audible and visual alarms are matched suitable to meet the regulatory radiation safety requirements
Area monitor ldquoFregatrdquo requires virtually no adjust-ment it is simple and convenient for installation and operation
BPI-1D LOCAL DISPLAY UNIT
Display of monitored parameters values received from external measuring devices
Purposebull Processing and display of values of monitored
parameters on information panel bull Comparison of values of monitored parameters
with thresholdsbull Transfer of monitored parametersrsquo values to
networkbull Generation of alarm in case of exceeding of preset
thresholds including external alarm devices
FeaturesTesting the unit and connected devicesbull Visually on the panelbull Using adjustment software when connected to
PC via USB
Automatic self-testing
The panel displays the following informationbull Diagnostic information about the status of con-
nected devicesbull Current date and timebull Values of measured parametersbull Position of measured values with respect to the
thresholds in the form of scales with green yellow and red zones
bull Time history (trend) for each measured value
Physical characteristicsTemperature range bull minus 10 divide + 50 ordmC
Maximum number of connected devicesbull measuring devices 15bull external audible and visual alarm 15
Display diagonal bull 152 cm (6)
Electrical characteristicsbull Interfaces RS-485bull Power supply 220 V 50 Hz 12 divide 24 V
Mechanical characteristicsbull Protection index IP54bull Paint decontaminable
Overall dimensions weightbull 296x248x118 mm 5 kg
DBG-S11D wide range gamma area monitor
UDMN-100 neutron area monitor
Ethernet RS-485
UDKS-100 gamma and X-ray area monitor
BPI-1D Local display unit
BAS-2 ldquoMicrordquo external visual alarm
BZS-2 ldquoMicrordquo external audible alarm
ldquoImpulsrdquo external display unit
Service workstation
Illuminated warning signs
SPC ldquoDozardquoRadiation monitoring equipment
4140
Continuous automatic monitoring of the gamma- X-ray ambient dose equivalent rate
Physical characteristicsbull Detector tissue-equivalent plastic scintillator
Oslash 45times20 mm
Measurement range bull Dose rate measurement range 01 μSvh divide 1 Svh bull Energy range 0015 divide 10 MeV
Mechanical characteristicsbull Protection index IP65bull Paint decontaminable
Overall dimensions weightbull Oslash72times265 mm 15 kg
UDKS-100 GAMMA AND X-RAY AREA MONITOR
UDMN-100 NEUTRON AREA MONITOR
Physical characteristicsbull detector ndash scintillator ZnS(Ag) Li-6
Measurement range bull 01 μSvh divide 01 Svh
Energy range bull 0025 eV divide 100 MeV
Temperature range bull minus 45 divide +50 ordmC
Electrical characteristicsbull Interfaces RS-485
Mechanical characteristicsbull Protection index IP 65bull Paint decontaminable
Overall dimensions weight bull 428times258times347 mm 115 kg
Continuous automatic monitoring of the neutron-radiations ambient dose equivalent ratebull Spherical polyethylene moderator Oslash 239 mm
MEASURING UNITS
DBG-S11D WIDE RANGE GAMMA AREA MONITOR
Continuous automatic monitoring of the gamma- ambient dose equivalent rate
Physical characteristicsbull Detector ndash GM counters
Measurement rangebull DBG-S11D 01 μSvh divide 10 mSvhbull DBG-S11D-01 01 μSvh divide 10 Svhbull DBG-S11D-02 01 μSvh divide 100 Svh
Energy rangebull 005 divide 30 MeV
Temperature range bull minus 40 divide +50 ordmC
Electrical characteristicsbull Interfaces RS-485 USB
Mechanical characteristicsbull Protection index IP 68bull Paint decontaminable
Overall dimensions weightbull DBG-S11D Oslash 68times141 mm 065 kg bull DBG-S11D-01 Oslash 68times179 mm 07 kgbull DBG-S11D-02 Oslash 68times179 mm 07 kg
Versionsbull DBG-S11Dbull DBG-S11D-01bull DBG-S11D-02
Reference standards Nuclear IEC 60846 IEC 60532 EMC IEC 61010 IEC 61000-6-2 Seismic IEC 60980
SPC ldquoDozardquoRadiation monitoring equipment
4342
ALARM UNITS
Generation visual signals of the excess of preset thresholds
Physical characteristicsLength of communication cablebull up to 1200 mbull Alarm Visual alarm green yellow red
Electrical characteristicsbull Power supply +12 V
Mechanical characteristicsbull Protection index IP 23
Overall dimensions weight 160times84times41 mm 02 kg
BAS-2 ldquoMICROrdquo EXTERNAL VISUAL ALARM
Generation audible signals of the excess of preset thresholds
Physical characteristicsLength of communication cablebull up to 1200 mbull Audible alarm 80 divide 100 dB at a distance of 1 m
Electrical characteristicsbull Power supply +12 V
Mechanical characteristicsbull Protection index IP 23
Overall dimensions weight 160times84times41 mm 02 kg
BZS-2 ldquoMICROrdquo EXTERNAL AUDIBLE ALARM
Physical characteristicsLength of communication cablebull up to 1200 m
Electrical characteristicsbull Power supply 220 V 50 Hz
Mechanical characteristicsbull Protection index IP 23
Overall dimensions weight bull 330times110times20 mm 05 kg
Physical characteristicsLength of communication cablebull up to 1200 m
Character height bull ldquoImpuls-910-Rrdquo 100 mmbull ldquoImpuls-915-D4Srdquo 150 mmbull ldquoImpuls-927-D4Srdquo 270 mm
Operating temperature rangebull ldquoImpuls-910-Rrdquo 0 divide +50 degCbull ldquoImpuls-915-D4Srdquo ldquo-727-D4Srdquo minus 40 divide +50 degC
Electrical characteristicsbull Power supply 220 V 50 Hz
Mechanical characteristicsProtection index bull ldquoImpuls-910-R IP 44bull ldquoImpuls-915-D4Srdquo ldquo-727-D4Srdquo IP 65
Overall dimensions weight bull ldquoImpuls-910-Rrdquo 400times160times60 mm 3 kgbull ldquoImpuls-915-D4Srdquo 815times250times80 mm 5 kgbull ldquoImpuls-927-D4Srdquo 1250times330times80 mm 5 kg
ILLUMINATED WARNING SIGNS
ldquoIMPULSrdquo EXTERNAL DISPLAY UNIT
SPC ldquoDozardquoRadiation monitoring equipment
4544
Individual threshold setting for each measurement channel
Continuous area and process monitoring
Collect amp display data from two measurement chan-nels (units with RS-485 or analog pulses)
Audible and visual alarms on exceeding preset thresholds or status of connected devices
Individual threshold setting for each measurement channel
Switching on the external alarm or executive devices when any threshold is exceeded
The wide panel displays the following information bull Values of measured parameters as min-1∙cm-2
s-1∙cm-2 μSvhbull Diagnostic information about the status of con-
nected devicesbull Current date and timebull Position of measured values with respect to the
thresholds in the form of scales with green yellow and red zones
bull Time history (trend) for each measured value
Physical characteristics Measurement range bull Count rate up to 107 CPM (170 kHz)
Operating temperature range bull minus 20 divide +50 ordmC
Electrical characteristics bull Power supply 220 V bull Interfaces USB
Mechanical characteristics bull Protection index IP 65 bull Overall dimensions weight 222times164times73 mm
40 kg
UIM-3D AREA MONITOR COUNT RATE METER
Measurement of alpha radiation flux density
Detector unit BDZA-100 (70 cm2) Measurement range 01 divide 104 min-1∙cm-2
Detector unit BDZA-100B (300 cm2) Measurement range 01 divide 2103 min-1∙cm-2
Measurement of beta radiation flux density
Detector unit BDZB-100 (28 cm2) Measurement range 10 divide 105 min-1∙cm-2
Detector unit BDZB-100L (30 cm2) Measurement range 10 divide 104 min-1∙cm-2
Detector unit BDZB-11D (84 cm2) Measurement range 5 divide 15∙104 min-1∙m-2
OPTIONAL PROBESMeasurement of gamma radiation flux density
Detector units BDEG-03 Measurement range 4 divide 2000 s-1∙cm-2
Detector unit UDKG-100 for operation in the rocks ore liquid media and sludge Measurement range 40 divide 8000 s-1∙cm-2
Measurement of the ambient dose equivalent rate
Detector unit DBG-S11D Measurement range 01 μSvh divide 100 Svh
Measurement of neutron radiation ambient dose equivalent rate
Detector unit BDMN-100 Measurement range 01 μSvh divide 01 Svh
SPC ldquoDozardquoRadiation monitoring equipment
46 47Reference standards Nuclear IEC 61526
Measurement of gamma-radiation personal dose equivalent Hp(10)bull Stand-alone dosimeter or composed of dosimetric
system onebull Audible and visual alarmbull Large memory dose accumulation historiesbull Exclusion of unauthorized intervention in dosim-
etry operation
DKG-05D PERSONAL GAMMA DOSIMETER
Physical characteristicsDetectors bull Silicon
Measurement range bull Dose rate 1 μSvh divide 10 Svhbull Dose 01 μSv divide 15 Sv
Energy range bull 005 divide 30 MeV
Electrical characteristicsbull Power supply rechargeable NiMH battery 1
alcaline battery (type AAA)
Operation timebull Till recharging not less 400 hoursbull With one set batteries not less 1000 hours
Mechanical characteristicsOverall dimensions weight bull 47times26times87 mm (with clip) 70 g
Environmental characteristicsbull IP65bull Temperature range minus 20 divide +45 ordmCbull Humidity up to 98 at 35 ordmCbull Shock vibration and drop resistant
Alarmbull Excess of alarm thresholdsbull Warnings of self-test failure and battery discharge bull Audible alarm 80 dB at 40 cmbull Visual alarm blinking LED
Relative equipmentbull One dosimeter charger ZU-1Mbull Chargestorage cassetes KZU-28KZU-56bull ldquoSmart chargingrdquo feature extends battery life timebull DKG-05D reader US-05bull DKG-05D system reader DVS-01D
Reader-PC interfacebull US-05 USB bull DVS-01D Ethernet
KZU-28
Physical characteristicsDetectors bull Silicon Li-6
Gamma measurement range bull Dose rate 1 μSvh divide 10 Svhbull Dose 01 μSv divide 15 Sv
Gamma energy range bull 005 divide 60 MeV
Neutron measurement range bull Dose rate 1 μSvh divide 2 Svhbull Dose 20 μSv divide 15 Sv
Neutron energy range bull 0025 eV divide 20 MeV
Electrical characteristicsPower supply bull Rechargeable NiMH batterybull Operatiion time till recharging not less 200 hours
Mechanical characteristicsOverall dimensions weight bull 47times26times87 mm (with clip) 70 g
Environmental characteristicsbull IP65bull Temperature range minus 20 divide +40 ordmCbull Humidity up to 75 at 30 ordmCbull Shock vibration and drop resistant
Alarmbull Excess of alarm thresholds bull Warnings of self-test failure and battery discharge bull Audible alarm 80 dB at 40 cmbull Visual alarm blinking LED
Relative equipmentbull One dosimeter charger ZU-1Mbull Chargestorage cassetes KZU-28 KZU-56bull ldquoSmart chargingrdquo feature extends battery life timebull DVS-02D reader UZS-01Sbull DVS-02D system reader DVS-01D
Reader-PC interfacebull UZS-01S USB bull DVS-01D Ethernet
UZS-01DReference standards Nuclear IEC 61526
DVS-02D GAMMA-NEUTRON PERSONAL ELECTRONIC DOSIMETER
Measurement of gamma- and neutron radiations personal dose equivalent Hp(10)bull Stand-alone dosimeter or composed of dosimetric
system onebull Audible and visual alarmbull Large memory dose accumulation historiesbull Exclusion of unauthorized intervention in dosim-
etry operationbull Both albedo thermal neutrons and intermediate
fast neutrons registrationbull Usable in the fields of Pu(Be) Po(Be) Cf and other
neutron sources as well as near nuclear reactors without neutron spectrum estimation
SPC ldquoDozardquoRadiation monitoring equipment
48 49
Dosimeters DVG-03D
DVGI-8D NEW PEN-TYPE PERSONAL IONIZATION CHAMBER DOSIMETERS
Measurement of personal dose equivalent Hp(10) of gamma and X-ray radiationbull Hp(10) of continuous and pulsed gamma and
X-ray radiation bull Electronic reader KSU-1bull Dosimeter DVG-03D with electronic ID bull Personal dose histories in the readerrsquos memorybull Readerrsquos connection with PC for database main-
tenance
Physical characteristicsDetector bull Ionization chamber
Measurement range bull 001 mSv divide 25 mSv
Energy range bull 0015 divide 25 MeV
Temperature range bull Reader KSU-1 +10 divide +50 ordmСbull Dosimeter DVG-03D minus 40 divide +50 ordmС
Electrical characteristicsPower supply bull Reader KSU-1 220 V 50 Hz built-in batteries bull Dosimeter DVG-03D four batteries CR 1025 bull Batteries life 3 yearsbull Readers interfaces RS-232USB 20
Mechanical characteristicsOverall dimensions weightbull Dosimeter DVG-03D Oslash 18times126 mm 005 kgbull Reader KSU-1 235times232times125 mm 28 kg
Reference standards Nuclear IEC 62387-1
DKG-02U ldquoARBITERrdquo WIDE RANGE GAMMA-DOSIMETER
Physical characteristicsDetectors bull GM counters
Measurement rangebull Dose-rate 01 μSvh divide 3 Svhbull Dose 1 μSv divide 100 Sv
Energy range bull 005 divide 3 MeV
Electrical characteristicsbull Power supply 2 alcaline batteries (type AA)bull Batteries life not less 200 hours
Mechanical characteristicsOverall dimensions weight bull 152times82times32 mm 03 kg
Environmental characteristicsbull Temperature range minus 20 divide +50 ordmCbull Humidity up to 90 at +25 ordmCbull Shock vibration and drop resistant
Reference standards Nuclear IEC 60846
Measurement of gamma radiation ambient equiva-lent dose H(10) and dose rate H(10)bull Audible signals (clicks) for radiation condition
estimationbull Analog scale for search modebull Audible and visual alarms of the excess of preset
dose and dose rate thresholds bull Shock-resistant water-proof easy decontamina-
tion casebull 100 measurement results memory with date and
time of measurementbull Indication of total dose accumulated during
exploitation time bull Indication of measurement result statistical
uncertainty
SPC ldquoDozardquoRadiation monitoring equipment
50 51
Physical characteristicsDetectors bull GM counter
Measurement rangebull Dose-rate 01 μSvh divide 3 mSvhbull Dose 1 μSv divide 02 Sv
Energy range bull 005 divide 3 MeV
Temperature range bull Minus 20 divide +50 ordmC
Electrical characteristicsbull Power supply 2 alcaline batteries 15 V (type AA)bull Batteries life not less 200 hours
Mechanical characteristicsOverall dimensions weight bull 122times74times29 mm 025 kg
Reference standards Nuclear IEC 60846
DKG-07D ldquoDROZDrdquoGAMMA-DOSIMETER
Measurement of gamma radiation ambient equiva-lent dose H(10) and dose rate H(10)bull Two independent measurement channels dose
and dose ratebull Audible signals (clicks) for radiation condition
estimationbull Continuous measurement with updating meas-
urement resultbull Measurement result can be obtained with any
desired statistical uncertainty (error)bull Automatic restart when radiation level sharply
changesbull Indication of statistical uncertainty (error) during
measurement process
Continuous measurement with updating measure-ment result
Automatic restart when radiation level sharply changes bull Gamma dose H(10) and dose-rate H(10) meas-
urementbull Beta and gamma contamination surveybull Indication of statistical uncertainty during the
measurementbull Continuous measurement with accuracy increas-
ing with time bull Automatic restart triggered by change of gamma
dose-ratebull Compensation of gamma count rate while meas-
uring beta radiationbull Indication of battery charge levelbull Audible signal of the excess of preset threshold
Physical characteristicsDetectors bull GM counter
Measurement range bull Dose-rate 01 microSvh divide 20 mSvhbull Dose 1 microSv divide 100 Svbull Beta flux density (for Sr-90+Y-90)
10 divide 105 cm-2 min-1
Energy range bull Gamma 005 divide 3 MeVbull Beta 01 divide 3 MeV
Temperature range bull Minus 20 divide +50 ordmC
MKS-15D ldquoSnegirrdquo backside
MKS-15D ldquoSNEGIRrdquoMULTI ndash PURPOSE RADIATION SURVEY METER
Reference standards Nuclear IEC 60846 IEC 60325
Electrical characteristicsbull Power supply 2 alcaline batteries (type AA)bull Battery life not less 400 hours
Mechanical characteristicsOverall dimensions weight bull 124times72times35 mm 035 kg
SPC ldquoDozardquoRadiation monitoring equipment
52 53
Physical characteristicsDetectorbull GM counter
Measurement range bull 01 μSvh divide 20 mSvh
Energy range bull 005 divide 30 MeV
Threshold setting range bull 03 μSvh divide 20 mSvh
Step change of the thresholdbull In the range 03 divide 10 μSvh with the step
001 μSvhbull In the range 10 divide 100 μSvh with the step
01 μSvhbull In the range 100 divide 2000 μSvh with the step
10 μSvh
Electrical characteristicsPower supply bull 220 V 50 Hz bull Relay output
Mechanical characteristicsProtection index bull IP 40
Overall dimensions weight bull 226times120times75 mm 07 kg
Alarmbull Sound alarm 80 divide 100 dBA at distance 1 mbull Visual alarm redbull Connection of the external alarm signaling unit
Reference standards Nuclear IEC 60846 IEC 60532
Continuous automatic monitoring of the ambient dose equivalent rate bull Measurement of gamma dose rate H(10)bull Audible and visual alarm signals for preset
thresholdsbull Switching on the external signaling or executive
devices
SRPS-05D GAMMA MONITOR
Measurement ofbull Gamma and X-ray personal dose equivalent
Hp(10)bull Neutron personal dose equivalent Hp(10)bull Lens dose equivalent Hp(3)bull Skin dose equivalent Hp(007)bull TLD reader day-to-day tests using built-in LEDbull No needs nitrogen for heating
Physical charachteristicsDetectors bull 7LiF Mg Ti (gamma beta)bull 6LiF Mg Ti (neutron)
Gamma and X-ray Hp(10) Measurement range bull 500 μSv divide 10 Sv
Energy range bull 0015 divide 30 MeV
Neutron Hp(10)Measurement range bull 01 mSv divide 100 mSv
Energy range bull 0025 eV divide 10 MeV
Beta and photons Hp(007) Hp(3) Measurement range bull 2 mSv divide 100 Sv
Energy range bull Beta 025 divide 35 MeVbull Photons lt15 keV
Mechanical characteristicsDosimeters overall dimensions weight bull Gamma Hp(10) DTL-2 holder - 62times26times16 mm
16 gbull DTU holder - 42times28times18 mm 8 gbull Lens Hp(3) face skin Hp(007) Oslash 32times16 mm 9 gbull Finger skin Hp(007) 90times20times2 mm 1 gbull Neutron gamma Hp(10) 48times40times20 mm 30 g
Reference standards Nuclear IEC 61066
DTL-2 DTU-2
MKD (A-type) DVNG-M
DOZA-TLD MULTIPURPOSE TLD SYSTEM
SPC ldquoDozardquoRadiation monitoring equipment
54 55
Continuous and pulsed gamma and X-ray dose H(10) and dose-rate measurementbull Alpha beta and gamma contamination surveybull Neutron dose H(10) and dose-rate measurementbull Gamma radiation flux density in boreholes and
liquid media measurement
Electrical characteristicsPower supply bull UIK-05 four C-size batteriesbull UIK-05-01 rechargeable batterybull UIK-06 rechargeable battery
Interfaces bull RS-232bull USB (via adapter)
bull Detector type automatic determination and corre-sponding measurement modes selection
bull Alarm threshold settings ndash for dose dose-rate alpha and beta contaminations
bull ldquoDetectrdquo and ldquoLocaterdquo modes for survey probes
Reference standards Nuclear IEC 60846 IEC 60325 IEC 61005 IEC 62363
Case
UIK-06 control unit165times78times48 mm 03 kg
DKS-96UNIVERSAL RADIATION SURVEY METER
UIK-05 control unit202times86times90 mm 10 kg
BDZA-96
BDZA-96B
BDZA-96M
BDZA-96S
BDZA-96T
EXTERNAL PROBES ALPHAALPHA BDZA-96Detector bull ZnS(Ag) 70 cm2
Measurement range (for Pu-239)bull 01 divide 104 min-1cm-2
Overall dimensions weightbull Oslash 130times240 mm 11 kg
ALPHA BDZA-96BDetector bull ZnS(Ag) 300 сm2
Measurement range (for Pu-239)bull 01 divide 2103 min-1cm-2
Overall dimensions weightbull Oslash 230times290 mm 40 kg
ALPHA BDZA-96MDetector bull ZnS(Ag) 10 сm2
Measurement range (for Pu-239)bull 01 divide 105 min-1cm-2
Overall dimensions weightbull Oslash 65times240 mm 09 kg
ALPHA BDZA-96SDetector bull ZnS(Ag) 30 сm2
Measurement range (for Pu-239)bull 01 divide 5104 min-1cm-2
Overall dimensions weightbull Oslash 90times240 mm 10 kg
ALPHA BDZA-96TDetector bull Silicon 5 сm2
Measurement range (for Pu-239)bull 01 divide 106 min-1cm-2
Overall dimensions weightbull Oslash 50times60 mm 015 kg
SPC ldquoDozardquoRadiation monitoring equipment
56 57
BETA BDZB-96Detector Scintillator 28 сm2
Measurement range (for Sr-90+Y-90)bull 10 divide 105 min-1cm-2
Energy rangebull 03 divide 30 MeV
Overall dimensions weightbull Oslash 90times230 mm 09 kg
BETA BDZB-99Detector bull GM counter 30 сm2
Measurement range (for Sr-90+Y-90)bull 20 divide 104 min-1см-2
Energy rangebull 012 divide 30 MeV
Overall dimensions weightbull Oslash 88times80 mm 04 kgbull Telescopic pole length 07 m
BETA BDZB-96BDetector bull GM counter 80 сm2
Measurement range (for Sr-90+Y-90)bull 3 divide 104 min-1сm-2
Energy rangebull 012 divide 30 MeV
Overall dimensions weightbull 150times200times110 mm 15 kg
BETA BDZB-96Sbull Detector GM counter 15 сm2
Measurement range (for Sr-90+Y-90)bull 10 divide 3104 min-1cm-2
Energy rangebull 012 divide 30 MeV
Overall dimensions weightbull Oslash 65times65 mm 03 kgbull Telescopic pole length 07 m
BDZB-96
BDZB-99
BDZB-96B
BDZB-96S
EXTERNAL PROBES BETA
GAMMA BDKS-96BDetector bull Tissue-equivalent scintillator Oslash 45times20 mm
Measurement rangebull Dose rate H(10) 01 μSvh divide 1 Svhbull Dose H(10) 01 μSv divide 10 Sv
Energy rangebull 0015 divide 10 MeV
Overall dimensions weightbull Oslash 60times250 mm 085 kg
GAMMA AND BETA BDKS-96SDetector bull Double GM counters
Measurement rangebull Gamma dose rate H(10) 01 μSvh divide 1 mSvhbull Gamma dose H(10) 01 μSv divide 10 Svbull Beta 10 divide 3104 min-1cm-2
Energy rangebull Gamma 005 divide 3 MeVbull Beta 012 divide 3 MeV
Overall dimensions weightbull Oslash 80times80 mm 035 kgbull Telescopic pole length 07 m
GAMMA BDMG-96Detector bull GM counters
Measurement rangebull Dose rate H(10) 01 μSvh divide 10 Svhbull Dose H(10) 01 μSv divide 10 Sv
Energy range bull 005 divide 3 MeV
Overall dimensions weightbull 40times250 mm 05 kgbull Telescopic pole length 07 m 4 m (by request)
EXTERNAL PROBES GAMMA
BDKS-96B
BDMG-96
BDKS-96S
SPC ldquoDozardquoRadiation monitoring equipment
58 59
GAMMA-SEARCH BDVG-96Detector bull Scintillator NaI(Tl) Oslash 63times63 mm
Measurement rangebull Flux density measurement range 4 divide 2000 s-1cm-2
bull Dose rate H(10) for Cs-137 01 divide 30 μSvhbull Sensitivity for Cs-137 3000 (pulsess-1)( μSvh-1)
Overall dimensions weightbull Oslash 88times400 mm 20 kgbull Modular pole length 16 m
GAMMA-SEARCH BDPG-96Detector bull Scintillator NaI(Tl) Oslash 25times40 mm
Measurement rangebull Flux density measurement range 10 divide 8000 s-1cm-2
bull Dose rate H(10) for Cs-137 01 divide 100 μSvhbull Sensitivity for Cs-137 500 (pulsess-1)( μSvh-1)
Overall dimensions weightbull 50times190times480 mm 10 kgbull Telescopic pole length 07 m
GAMMA-SEARCH BDPG-96MDetector bull Scintillator NaI(Tl) Oslash 18times30 mm
Measurement rangebull Flux density measurement range 10 divide 24000 s-1cm-2
bull Dose rate H(10) for Cs-137 01 divide 300 μSvhbull Sensitivity for Cs-137 200 (pulsess-1)( μSvh-1)
Overall dimensions weightbull Oslash 35times320 mm 05 kgbull Telescopic pole length 07 or 38 m
EXTERNAL PROBES GAMMA
BDVG-96
BDPG-96M
BDPG-96
EXTERNAL PROBESGAMMA BDKG-96 STAINLESS STEEL CASING FOR GEOLOGIC APPLICATIONS WELL LOGGINGDetector bull Scintillator NaI(Tl) Oslash 18times30 mm
Measurement rangebull Flux density measurement range 10 divide 105 s-1cm-2
bull Dose rate H(10) for Cs-137 5 divide 2104 μRhbull Sensitivity for Cs-137 200 (pulsess-1)( μSvh-1)
Overall dimensions weightbull Oslash 38times535 mm 36 kgbull Cable length 10 divide 1000 m
NEUTRON BDMN-96Detector bull Scintillator with ZnS(Ag)
Measurement rangebull Dose rate H(10) 01 μSvh divide 01 Svhbull Dose H(10) 01 μSv divide 10 Sv
Energy range bull 0025 eV divide 10 MeV
Overall dimensions weightbull Detector Oslash 54times200 mm 08 kgbull Moderator Oslash 245 mm 73 kg
NEUTRON-SEARCH BDKN-96Detector bull He-3 counter in polyethilene moderator
Measurement rangebull Dose rate H(10) for Pu-Be 01 μSvh divide 01 Svhbull Dose H(10) for Pu-Be 01 μSv divide 10 Sv
Energy range bull 0025 eV divide 14 MeV
Overall dimensions weightbull 295times142times100 mm 225 kg
BDKG-96M
BDMN-96
BDKN-96
SPC ldquoDozardquoRadiation monitoring equipment
60 61
bull No gas supply neededbull Clothing control detachable right hand detector bull Alpha detector optional connection bull Numeric and color (red green) indication of
control resultsbull LED sensor of hand-foot positioning for start of
measurementbull Automatic compensation of gamma background
and contamination of detectorbull Audible alarm signals of the excess of preset
thresholdsbull Measurement value indication min-1cm-2 or
Bqсm2
Reference standards Nuclear IEC 61098
RZB-05D HAND-FOOT-CLOTHING MONITOR
Physical characteristicsDetectors bull Gamma beta - GM countersbull Alpha - scintillatior ZnS(Ag)
Detecting nuclidesbull Alpha Pu-239 U-234 U-238bull Beta Sr-90+Y-90 F-18 Cs-137 Co-60 Tс-99 O-15
N-13 Sr-89 C-11 I-131 Na-22 Ru-106+Rh-106 Tl-204
bull Gamma Tc-99m I-123
Efficiencybull Alpha
Pu-239 40 U-234 25U-238 15
bull Beta Sr-90 +Y-90 40
Measurement range bull Alpha 1 divide 103 min-1cm-2 bull Beta 10 divide 103 min-1cm-2
bull Gamma 5103 divide 5106 min-1cm-2
Energy range bull Alpha 30 divide 80 MeV bull Beta 008 divide 35 MeV bull Gamma 005 divide 30 MeV
Operation temperature range bull Minus 10 divide +50 ordmС
Electrical characteristicsbull Power supply 220 V 50 Hz
Mechanical characteristicsOverall dimensions weight bull 740times750times1180 mm 45 kg
Versionsbull Withwithout alpha detectorbull Indication (min-1cm-2 ) or (Bqсm2)bull Detectors overall dimensions smbull Hand 178 х 235bull Foot 185 х 436
Whole body contamination monitor RZBA-04-04Mbull No gas supply neededbull Compensation for background gamma radiation
and contamination of detector unitsbull Individual threshold setting for each measure-
ment channelbull Visible and audible alarms ldquoCONTAMINATIONrdquo and
ldquoCLEANrdquo bull Indication of contaminated body parts on the
panel with image of the bodybull Optional remote alpha-detector
Physical characteristicsDetectors bull Beta - GM counters scintillatorsbull Alpha - scintillatior ZnS(Ag)
Measurement range bull Beta 5 divide 15000 min-1cm-2
bull Alpha 01 divide 10000 min-1cm-2
Energy range bull Beta 015 divide 25 MeV bull Alpha 40 divide 56 MeV
Operation temperature range bull +5 divide +50 ordmС
Electrical characteristicsPower supply bull 220 V 50 Hz
Interfaces bull RS-232bull RS-485
Mechanical characteristicsOverall dimensions weight bull 2650times940times930 mm 310 kg
Versionsbull Withwithout alpha detectorbull Indication (min-1cm-2 ) or (Bqсm2)
Reference standards Nuclear IEC 61098
RZBA-04-04MWHOLE BODY CONTAMINATION MONITOR
SPC ldquoDozardquoRadiation monitoring equipment
62 63
RZA-05DALPHA HAND-MONITOR
bull No gas supply needed bull Numeric and color (red green) indication of
control resultsbull LED sensor of hand- positioning for start of
measurementbull Audible alarm signals of the excess of preset
thresholdsbull Measurement value indication min-1cm-2 or
Bqсm2
Physical characteristicsDetectors alpha - scintillatior ZnS(Ag)
Efficiencybull Pu-239 20 bull U-234 14bull U-238 8
Measurement range bull 05 divide 105 min-1cm-2
Energy range bull 41 divide 90 MeV
Operation temperature range bull minus 10 divide +50 ordmС
Electrical characteristicsPower supply bull 220 V 50 Hz
Mechanical characteristicsOverall dimensions weight no more bull 740times1400times1450 mm 70 kg
Reference standards Nuclear IEC 61098
bull Simultaneous measurement of alphabeta activi-ties in the sample
bull Active shielding anti-coincidence background subtraction using GM counters
bull Lead shielding 30 mm
UMF-2000 LOW LEVEL ALPHA- BETA- COUNTER
Physical characteristicsDetectors bull Silicon specrometric detector 500 or 1000 mm2
Measurement range bull Alpha 001 divide 1000 Bq bull Beta 01 divide 3000 Bq
Energy range bull Alpha 35 divide 80 MeV bull Beta 005 divide 35 MeV
Electrical characteristicsPower supply bull 220 V 50 Hz
Interfaces bull RS-232bull USB
Mechanical characteristicsOverall dimensions weight bull 337times286times190 mm 22 kg
Versionsbull Detector area 500 mm2
bull Detector area 1000 mm2
UMF-2000 Detector area 1000 mm2
UMF-2000 Detector area 500 mm2
SpectraDec software for alpha-spectrometric measurements
SPC ldquoDozardquoRadiation monitoring equipment
64 65
DRK DOSE AREA PRODUCT METER
DRK-1bull Diagnostic reference level (DRL) of patients
determinationbull Suitable for all basic types of x-ray machines
Physical characteristicsDetector bull Plane-parallel ionization chamber
Measurement range bull 1 divide 104 cGycm2
Electrical characteristicsPower supply bull 220 V 50 Hz
DRK-1M-CTbull Measuring of dose length product
Physical characteristicsDetector bull Pencil Ionization Chamber
Measurement rangebull 05 divide 109 microGym
DRK-1Mbull Measuring of air kerma on sectional area of the
X-ray beam productbull Measuring of air kerma rate on area productbull Measuring of air kerma ratebull Measuring of air kerma
Physical characteristicsDetector bull Plane-parallel ionization chamber
Measurement rangebull 01 divide 109 microGym2
bull 06 divide 6104 microGym2cbull 30 divide 9105 microGycbull 30 divide 9991011 microGyReference standard IEC 60580 2003
bull Measurement of strontium-90 in the foodstuffs agricultural products etc
bull Measurement of gross beta activity in samplebull Self tests using built-in LED
ldquoPROGRESS-BETArdquo SCINTILLATION BETA SPECTROMETER
Physical characteristicsDetector bull Plastic scintillator Oslash70x10 mm
Sample bull Plate Oslash70 mmbull Weight up to 15 g
Energy range bull 02 divide 30 MeV
Minimum detectable activity of Sr-90 in a 10 g sample on a standard planchet Bqsamplebull In case of absence of K-40 in the sample 01 Bqbull In case the activity of K-40 till 5 Bqg 05 Bq
Electrical characteristics Interface bull USB
Mechanical characteristicsWeight bull No more 50 kg
Complete setBasic complete setbull Detector unit with plastic scintillator integrated
power supply amplifier ADC bull Lead shielding bull ldquoProgressrdquo software bull Сheck source for energetic calibration (Sr-90-Y-90) bull Planchet Oslash 70 mm (5 items) bull Sample dencification device bull Procedure manual for measurement of radio-
nuclidesrsquo activity using the scintillation beta spec-trometer ldquoProgressrdquo
Optional equipment and servicebull Personal computer and printer bull Calibrations for radionuclides not included in the
main library of radionuclides
Progress-Beta
Reference standards IEC 61562
SPC ldquoDozardquoRadiation monitoring equipment
66 67
bull Measurement of gamma activity in foodstuffs soil samples and others environmental objects
bull Identification of radionuclides in the sample bull Automatic correction for sample density bull Self-tests using built-in LED
ldquoPROGRESS-GAMMArdquoSCINTILLATION GAMMA SPECTROMETER
Physical characteristicsDetector bull NaI (Tl) Oslash63times63 mm
Validated measurement geometries bull Marinelli beakers (1 liter) Petri dishes (Oslash90 mm)
etc
Energy range bull 02 divide 30 MeV
Minimum detectable activity Bqsamplebull Cs-137 3 Bqbull Th-232 7 Bqbull Ra-226 8 Bq bull К-40 40 Bq
Electrical characteristics Interface bull USB
Mechanical characteristicsWeight bull No more 120 kg
Complete setBasic complete setbull Scintillation detector unit with NaI (Tl) detector
with integrated power supply amplifier and ADC bull Lead shielding 50 mm bull ldquoProgressrdquo software bull Сheck source for energy calibration (Cs-137 +
K-40)bull Marinelli beakers - 1 liter (5 items) bull Petri dishes Oslash 90 mm (5 items) bull Procedure manual for measurement of activity
of radionuclides using the scintillation gamma spectrometer ldquoProgressrdquo
Optional equipment and servicebull Kit for radon measurements including calibration
of ldquoIC-63rdquo geometry for counting the charcoal samples
bull Personal computer and printer bull Calibrations for user defined geometries bull Calibrations for radionuclides not included in the
main library of radionuclides
Progress-Gamma
Reference standards IEC 61563
ldquoPROGRESS-G(P)rdquoPORTABLE SCINTILLATION GAMMA SPECTROMETERbull Field measurements of gamma activity in environ-
mental objects without sampling (4π geometry)bull Laboratory measurement of gamma activity in
foodstuffs soil samples and others environmental objects
bull Identification of radionuclides in the sample bull Automatic correction for sample densitybull Tests using built-in LED
Physical charachteristicsDetector bull NaI (Tl) Oslash45times50 mmbull Lead shielding 20 mm
Validated measurement geometries bull Marinelli beakers (05 liter) Petri dishes (Oslash90 mm)
etc
Energy range bull 02 divide 30 MeV
Minimum detectable activity in 05-litre Marinelli beaker bull Cs-13710 Bqkgbull К-40100 Bqkgbull Ra-22618 Bqkg bull Th-23216 Bqkg
Minimum detectable activity in 30 min (4π geometry) bull Cs-137 2 Bqkgbull К-40 30 Bqkgbull Ra-226 4 Bqkg bull Th-232 3 Bqkg
Electrical characteristicsPower supply bull Rechargeable batterybull 220 V 50 Hz
Interface bull USB RS-232
Weight bull No more than 60 kg
Complete setBasic complete setbull Scinttillation detector unit with NaI(Tl) bull ldquoProgressrdquo softwarebull Сontrol unit ldquoSputnikrdquo for aquisition and analisys
of spectra with built-in memory for spectral databull Casebull Lead shielding (2 cm) for laboratory usebull 05-litre Marinelli beakers ndash 5 itemsbull Na-22 check sourcebull Power adapter BPS-01bull Operation manualbull Procedure manual for measurement of activity
of radionuclides using the scintillation gamma spectrometer ldquoProgressrdquo
Optional equipment and servicebull Kit for radon measurements with charcoalbull Built-in dose rate meterbull Additional memory (RAM) for storage of 64
spectrabull Additional power adapterbull Notebook and printer
Progress-Gamma
Reference standards IEC 61563
SPC ldquoDozardquoRadiation monitoring equipment
68 69
Physical characteristicsDetectorbull Scintillation detector ZnS (Oslash 60 mm)
Samplebull Thin sample - diameter up to 70 mm bull Preparation technique - electro-depositionbull Thick sample - diameter 70 mm weight
200300 mg bull Preparation technique - application of powders
(prepared by radiochemical concentration by water evaporation or by pounding of mineral samples) onto a planchet with the help of spirit
Energy rangebull 15 divide 8 MeV
Minimum detectable activitybull Thin samples no more than 910-3 Bqsamplebull Thick samples no more than 180 Bqkg
Mechanical characteristicsOverall dimensions weightbull 195times120times210 mm 34 kg
Complete setBasic complete setbull Alpha radiometer ldquoProgress-ARrdquobull Check source (uranium isotopes)
Set of accessoriesbull Procedure manual for measurements of radi-
oactivity using scintillation alpha radiometer ldquoProgress-ARrdquo
bull ldquoProgressrdquo software
ldquoProgress-ARrdquo
bull Measurement of gross activity of alpha emitting radionuclides in thin samples
bull Measurement of gross activity of alpha emitting radionuclides in thick samples
bull Measurement of activity deposited on aerosol filters
ldquoPROGRESS-ARrdquoALPHA RADIOMETER
Several fixed positions of the detector enable to perform measurements in various geometries and to estimate the content ofbull Cs-137 in the whole bodybull I-131 in thyroidbull Co-60 Cs-137 Mn-54 Cr-51 in lungsbull Database for storage of measurement data and
resultsbull Uncertainty calculations based on measurement
databull Self tests using built-in LED
ldquoPROGRESSrdquo WHOLE BODY COUNTER
Physical characteristicsDetectorbull scintillation detector NaI (Tl) Oslash63times63 mm
Energy rangebull 02 divide 28 MeV
Minimum detectable activitybull By Cs-137 in the whole body - 1200 Bqbull By I-131 in thyroid - 100 Bqbull By Co-60 Cs-137 Mn-54 Cr-51 in lungs - 200 Bq
Mechanical characteristicsWeight bull No more than 120 kg
Complete setBasic complete setbull Collimator with rotator and holderbull Detector with incorporated ADCbull Patient chair and table for collimatorbull Check source Na-22bull Procedure manual for lifetime measurement of
gamma-emitting radionuclidesrsquo activity in human body using the gamma-spectrometer of human radiation ldquoProgressrdquo
bull laquoProgressraquo software
Optional equipment and servicebull Program of internal radiation committed internal
radiation effective dose calculation by the stand-ard model
bull Background phantombull Personal computer and printer
Collimator with rotator and holder
SPC ldquoDozardquoRadiation monitoring equipment
70 71
bull Categorization of wastes for the purpose of fur-ther processing including wastes with unknown radionuclide composition
bull Measurements during the incoming waste inspec-tion (accepting for storage disposal)
bull Certification of unconditioned and conditioned wastes in closed containers without opening them (at nuclear plants or at facilities providing collection storage transportation conditioning processing temporal storage and final disposal of radioactive waste)
bull Activity measurement of extended objects in situ without opening the equipment
bull Activity measurement of extended objects after opening (for example assessment of tubes used for oil transportation)
MKG-01D ldquoSADOVNIKrdquoSPECTROMETRY SYSTEM
Physical charachteristicsDetectorbull Detector unit GEM (GMX) with HPGe detector and
multi-positioning cryostat CFG-PMOD4-7 with 7 litre Dewar
bull Dose rate probe BDMG-200
Energy range bull With GEM detector 004 divide 30 MeVbull With GMX detector 0005 divide 15 MeVbull Dose rate probe BDMG-200 ndash 005 divide 30 MeV
Measurement rangebull 110-7 divide 10 Svhbull Relative efficiency of detection (in photopeak) at
13325 MeV (Co-60) 10 divide 150
Electrical characteristicsPower supplybull 220 V 50 Hz
Interfacebull USB
Complete setBasic complete setbull Spectrometric detector unit GEM (GMX) with
HPGe detector and multi-positioning cryostat with 7 litre Dewar
bull Portable digital multichannel analyzer DigiDARTbull Dose rate probe BDMG-200bull Autonomous power supply unit with built-in
batterybull Industrial computer keyboardbull Laser range-finderbull Thermographic printerbull Web-camerabull Device equipped with stepper motor for position-
ing of the spectrometric detectorbull Calibration device with reference sources
(Am-241 Co-60 Ba-133 Eu-152) for energy calibration
bull Removable collimators with end capbull Measurement proceduresbull ldquoClasterrdquo software
bull Measurement of gross alpha activity of alpha-emitting radionuclides
bull Measurement of alpha-emitting radionuclides activity in thin-layer samples meeting alpha-spectrometry requirements
Physical characteristicsDetectorbull Silicon ion-implanted 450 mm2
bull Easy to decontaminate thin windowbull dead layer less than 015 μmbull Background count rate in the range 3 divide 9 MeVbull No more than 09 h-1cm-2 for 450 mm2 detector
Energy rangebull 2 divide 9 MeVbull Lower limit of measurement range (minimum
detectable activity) 01 Bqbull Background count rate no more than 100 counts
in 24 hours
Electrical characteristics Power supplybull 220 V 50 Hz
Interfacebull USB
Complete setBasic complete setbull Detector unit with vacuum measuring chamber
and vacuum control systembull Low noise vacuum pump (type 2FY-05B or
equivalent)bull Check sourcebull ldquoProgressrdquo softwarebull Vacuum tube
MKS-01A ldquoMULTIRAD-ASrdquoALPHA SPECTROMETER
SPC ldquoDozardquoRadiation monitoring equipment
72 73
UCRV-2AIRFLOW MONITOR
bull Monitor of the air flow through filter of centralized multichannel sampling system
bull Radiation monitoring system (RMS) integration for internal exposures determination
bull Volume and flow rate measurements of the air that have passed through a analytical filter
bull Bar-code for filter identificationbull Operation as either standalone unit or as a part of
the RMS
Physical characteristicsMeasurement range of air volume bull 001 divide 9999 m3
Operation temperature range bull minus 20 divide +50 ordmС
Electrical characteristicsPower supply bull 220 V 50 Hz
Interface bull RS-485
PVP-06PORTABLE AIR SAMPLER
Air Sampler PVP-06 is indispensable for monitoring the radiation situation where the concentration of radioactive aerosols in the air does not require a sta-tionary sampling equipment Sampling head PVP-06 provides easy change of filters and cartridges
Purposebull To monitor the concentration of radioactive aero-
sols in the air sites
Controlled aerosolsbull Alpha- and beta-active aerosolsbull Daughter products of decay of radon and thoronbull Iodine isotopes
Physical characteristicsTypes of filtersbull Aerosol AFA-RSP-20bull Iodine AFA SI-20
Flow rate bull 33∙10-4 ndash 233∙10-4 m3s (20 divide 140 l min)
Electrical characteristicsPower supply bull 220 V50 Hzbull The vehicle power supply 108 divide 145 Vbull Internal battery
Minimal working time on internal battery to recharge bull 8 hours
Power consumption (at a flow rate of 100 lmin) bull 40 VA
Environment characteristicsOperating temperature bull minus 10 divide +40 deg C
Maximum humidity bull 90
Pressure bull 860 to 1060 hPA
Noise generated by the pump bull lt 55 dBA at 1 m
Mechanical characteristicsDimensions weight bull 241 times 108 times 160 mm 28 kg
Case material bull Plastic
Complete setbull Air sampler PVP-06bull AC power adapterbull Filters AFA-RSP-20 - 100 pcsbull Packaging for filters - 40 pcsbull Casebull Operation manualbull Calibration certificate
Optional equimpient bull Kit for sampling sorption columns of activated
carbon Ř head of sorption columns with protective
covers Ř activated charcoal SKT-3 - 1 pkg (02 L) Ř charocoal samples SC-13 - 8 pcs
bull Car charger bull Tipod bull Shoulder strapbull Calibration stand bull Filters AFA SI-20 - 100 pcs
Consumablesbull Aerosol filters AFA RSP-20bull Iodine filters AFA SI-20
SPC ldquoDozardquoRadiation monitoring equipment
74 75
Calibration of gamma dose and dose rate meters
Calibration ofbull Ambient equivalent dose H(10) meters (Sv Svh)bull Personal equivalent dose Hp(10) meters (Sv Svh)bull Exposure dose X meters (R Rh)bull Two sources in irradiator bull Select source and collimator opening using
tumbler
UPG-P DESKTOP GAMMA BEAM IRRADIATOR
Physical characteristicsRange of reproduced dose rate bull 05 μSvh divide 10 mSvh (50 μRh divide 100 mRh)
Sources activities bull 6times106 6times108 Bq (02 20 mCi) Cs-137
Overall dimensions bull 1250times400times300 mm
Irradiator weight bull Not more than 37 kg
Calibration bench weight bull Not more than 15 kg
Reference standards IEC 60846 IEC 61526
Physical characteristicsDetectorbull Silicon
Measurement range EEC measurement bull Measurement range of radon EEC
10 divide 10bull106 Bqbullm-3
bull Measurement range of thoron EEC 05 divide 10bull104 Bqbullm-3
bull Air flow through the filter 100plusmn05 lmin
Concentration measurementbull Measurement range of radon-222 concentration
in air 10 divide 20bull106 cpsbull Measurement range of 216Po(ThA)
1bull10-3 divide 1bull102 cpsbull Air sampler flow rate
10plusmn02 lminbull Measurement range of radon-222 concentration
in water samples 6 divide 800 Bqbullkg-1
bull Measurement range of radon-222 flux from soil surface 20 divide 103 mBqsbullm2
bull Measurement range of radon-222 concentration with preliminary sampling of air using air sam-plers 20 divide 107 Bqbullm-3
bull Measurement range of radon-222 concentration in samples of soil air 103 divide 106 Bqbullm-3
Operation temperature range bull 1 divide 35 ordmC
Electrical characteristicsPower supply bull 80 VA
Mechanical characteristicsOverall dimensions weight bull 220times200times165 mm 36 kg
ldquoALPHARAD PLUSrdquoRADON THORON amp THEIR PROGENY MONITORbull Measurement of radon and thoron concentration
and effective equivalent concentration (EEC)bull In the airbull In the indoor air of residential public and industri-
al buildings and structuresbull Measurement of radon in drinking water sourcesbull Measurements of radon flux from the soil surface
at land plots allocated for construction of houses public buildings and industrial facilities
bull Measurements of radon concentration in soil air
Reference standards IEC 61577
SPC ldquoDozardquoRadiation monitoring equipment
76 77
UKPN-2M-D NEUTRON BEAM IRRADIATOR
Reference standards IEC 61005 61322
Calibration of neutron dose and dose rate meters
Calibration ofbull Ambient equivalent dose H(10) meters (Sv Svh)bull Personal equivalent dose Hp(10) meters (Sv Svh)bull Flux density of neutrons (cm-2∙s-1)bull Transfer container for temporary storage of
sources bull Red light signal of source working position
Physical carachteristicsRange of reproduced dose ratebull 20 divide 800 μSvh
Range of reproduced flux densitiesbull 10 divide 400 cm-2∙s-1
Type of a source in use bull Pu-Be
Activity of a source in usebull 24х1011 Bq (with density of 107 s-1)
Overall dimensions weight no morebull 3000x750x2000 mm 300 kg
Required room dimensionsbull not less than 7x3x3 m
Electrical characteristicsPower supply bull 220 V 50 Hz
Calibration of gamma dose and dose rate meters
Calibration ofbull Ambient equivalent dose H(10) meters (Sv Svh)bull Personal equivalent dose Hp(10) meters (Sv Svh)bull Exposure dose X meters (R Rh)bull Four sources in irradiator bull Select source and move to working position
return to storage position using special rodbull Transfer container for temporary storage of
sources bull Red light signal of source working position
UPGD-2M-DGAMMA BEAM IRRADIATOR
Physical characteristicsRange of reproduced dose rate bull 05 μSvh divide 50 mSvh (50 μRh divide 5 Rh)
Maximum activity of source bull 2times1011 Bq (50 Ci) Cs-137
Overall dimensionsbull Irradiator 800times500times500 mmbull Guide rails length 30 mbull Height 16 mbull Weight not more than 700 kgbull Required room dimensions not less than 7x3x3 m
Electrical characteristicsPower supply bull 220 V 50 Hz
UPGD-2M-D
Reference standards IEC 60846 IEC 61526 IEC 61066
SPC ldquoDozardquo
78 79
Contents
MEASURING UNITS
DBG-S11D wide range gamma area monitor 40
UDKS-100 gamma and X-ray area monitor 41
UDMN-100 neutron area monitor 41
ALARM UNITS
BAS-2 ldquoMICROrdquo external visual alarm 42
BZS-2 ldquoMicrordquo external audible alarm 42
Illuminated warning signs 43
ldquoImpulsrdquo external display unit 43
UIM-3D area monitor count rate meter 44
DKG-05D personal gamma dosimeter 46
DVS-02D gamma-neutron personal electronic dosimeter 47
DVGI-8D new pen-type personal ionization chamber dosimeters 48
DKG-02U ldquoARBITERrdquo wide range gamma-dosimeter 49
DKG-07D ldquoDROZDrdquo gamma-dosimeter 50
MKS-15D ldquoSNEGIRrdquo multi ndash purpose radiation survey meter 51
SRPS-05D gamma monitor 52
DOZA-TLD multipurpose TLD system 53
DKS-96 universal radiation survey meter 54
EXTERNAL PROBES ALPHA
Alpha BDZA-96 55
Alpha BDZA-96B 55
Alpha BDZA-96M 55
Alpha BDZA-96S 55
Alpha BDZA-96T 55
EXTERNAL PROBES BETA
Beta BDZB-96 56
Beta BDZB-99 56
Beta BDZB-96B 56
Beta BDZB-96S 56
EXTERNAL PROBES GAMMA
Gamma BDKS-96B 57
Gamma and beta BDKS-96S 57
Gamma BDMG-96 57
EXTERNAL PROBES GAMMA
Gamma-search BDVG-96 58
Gamma-search BDPG-96 58
ContentsRadiation monitoring systemldquoPELIKANrdquo Radiation monitoring system (RMS) 6
BDMG-101 high range gamma area monitor 10
DBG-S11D wide range gamma area monitor 11
BDRG-52 high range gamma area monitor for accident and post-accident conditions 12
UDGP-01 Liquid technological environments monitor 13
UDMN-100 neutron area monitor 14
UDKG-100 Wel Liquid gamma monitor 14
BOP-1M data processing and transmission unit 15
UDA-1AB particulate monitor 16
UDG-1B noble gas monitor 17
UDG-03D noble gas monitor 18
UDI-1B iodine monitor 19
UDGB-01 noble gasesH-3C-14 monitor 20
UDGP-01 steam generator leakage monitor 21
UPPVM air flow parameters monitor 22
ldquoIMPULSrdquo external display unit 23
BI-2 remote display amp alarm unit 24
BASBAS-1s external alarm 25
SKGAV stack monitor 26
RMS software 28
RMS workstation ndash operator console 29
Configurator software 29
RM RACK radiation monitoring rack 30
SRKS-01D criticality accident alarm system 32
ldquoATLANT-Mrdquo environmental radiation monitoring system 34
ldquoBREEZErdquo high-volume air sampler 35
ldquoGAMMA-SENSORrdquo gamma-survey system 36
Radiation monitoring equipmentAREA MONITOR ldquoFREGATrdquo 38
BPI-1D local display unit 39
80
Gamma-search BDPG-96M 58
Gamma BDKG-96 stainless steel casing for geologic applications well logging 59
EXTERNAL PROBES NEUTRON
Neutron BDMN-96 59
Neutron-search BDKN-96 59
RZB-05D Hand-foot-clothing monitor 60
RZBA-04-04M whole body contamination monitor 61
RZA-05D alpha hand-monitor 62
UMF-2000 low level alpha- beta- counter 63
DRK dose area product meter 64
ldquoPROGRESS-BETArdquo scintillation beta spectrometer 65
ldquoPROGRESS-GAMMArdquo scintillation gamma spectrometer 66
ldquoPROGRESS-G(P)rdquo portable scintillation gamma spectrometer 67
ldquoPROGRESS-ARrdquo alpha radiometer 68
ldquoPROGRESSrdquo whole body counter 69
MKG-01D ldquoSADOVNIKrdquo spectrometry system 70
MKS-01A ldquoMULTIRAD-ASrdquo alpha spectrometer 71
UCRV-2 airflow monitor 72
PVP-06 portable air sampler 73
ldquoALPHARAD PLUSrdquo radon thoron amp their progeny monitor 74
UPG-P desktop gamma beam irradiator 75
UPGD-2M-D gamma beam irradiator 76
UKPN-2M-D neutron beam irradiator 77
Radiation monitoring system SPC ldquoDozardquo
12 13Reference standards EMC IEC 61010 IEC 61000-6-2 Seismic IEC 60980
bull Continuous automatic monitoring of the ab-sorbed dose rate
bull Monitoring inside containmentbull Delivery assembled detector and communication
linebull Communication line include inter wall protective
tubebull Hermetic communication line filled dry nitrogen
Physical characteristicsbull detector - stainless steel ionization chamber
Measurement range bull 10-3 divide 105 Gyh
Energy range bull 006 divide 30 MeV
Temperature range bull detector
0 divide 207 ordmC continuous
250 ordmC during 1 hour bull electrometric module 0 divide +60 ordmC
Detector operating pressure bull 07 МPa
Electrical characteristicsbull Interfaces RS-485bull detector-electrometric module cable length up
to 70 m
BDRG-52 HIGH RANGE GAMMA AREA MONITOR FOR ACCIDENT AND POST-ACCIDENT CONDITIONS
Ionization chamber
Mechanical characteristicsProtection index bull detector - IP 65bull electrometric module - IP 23bull Paint stainless steel
Overall dimensions weight bull detecting unit Oslash50х220 mm 3 kgbull inter wall protective tube Oslash 159 length (by order)
1200 ndash 1600 mm 60 kgbull electrometric module 420x420x120 mm 8 kg
Reference standards Nuclear IEC 60951 EMC IEC 61010 IEC 61000-6-2 Seismic IEC 60980
Continuous monitoring of technological environ-ments liquid couples sludges etc bull On line gamma spectrometry
Physical characteristicsbull Detector ndash scintillator CsI NaI
Measurement range bull Gamma-activity 10bull104 divide 20bull108 Bqm3
Energy range bull gamma 005 divide 15 MeV
Temperature range bull minus 10 divide +80 ordmС
UDGP-01 LIQUID TECHNOLOGICAL ENVIRONMENTS MONITOR
Electrical characteristicsbull Interfaces RS-232 RS-485 Ethernetbull programmable relay output (SPDT relay)
Mechanical characteristicsbull Protection index IP 65bull Paint decontaminable
Overall dimensions weight bull Detector unit
CsIOslash 60x360 mm17 kg NaIOslash 35x750 mm26 kg
bull Data processing and transmission unit BOP-1sp 280x220x114mm 43 kg
Alarmbull Sound alarm 80 divide 100 dBA at distance 1 mbull Visual alarm green yellow redbull Connection of the external alarm unit of ldquoBASrdquo
type
Radiation monitoring system SPC ldquoDozardquo
14 15
BOP-1M DATA PROCESSING AND TRANSMISSION UNIT
bull Processing of data incoming from detecting blocks UDMN-100 DBG-S11D UDKG-100 BDMG-101 BDRG-52
bull Data transmission to the network bull Data transmission to the mobile computer bull Storage of thresholds values and parameters of
detecting blocksbull Power supply and diagnostics of detecting blocks bull Generation of the alarm signals of the excess of
preset thresholdsbull Data backup in the non-volatile memory
Physical characteristicsbull Quantity of joined detecting blocks and alarm
units ndash up to 20bull Temperature range minus 40 divide +50 ordmC
Electrical characteristicsbull Power supply 85 divide 260 V 47 divide 440 Hzbull Interfaces RS-232 RS-485 Ethernet bull programmable relay output (SPDT relay)
Mechanical characteristicsbull Protection index IP 65 bull Paint decontaminable
Overall dimensions weightbull 298times220times114 mm 5 kg
Reference standards EMC IEC 61010 IEC 61000-6-2 Seismic IEC 60980
Continuous automatic monitoring of the neutron-radiations ambient dose equivalent ratebull Spherical polyethylene moderator Oslash 239 mm
UDMN-100 NEUTRON AREA MONITOR
Physical characteristicsbull detector ndash scintillator ZnS(Ag) Li-6
Measurement range bull 01 μSvh divide 01 Svh
Energy range bull 0025 eV divide 100 MeV
Temperature range bull minus 45 divide +50 ordmC
Electrical characteristicsbull Interfaces RS-485
Reference standards Nuclear IEC 61005 IEC 61322 EMC IEC 61010 IEC 61000-6-2 Seismic IEC 60980
UDKG-100WEL LIQUID GAMMA MONITOR
Mechanical characteristicsbull Protection index IP 65bull Paint decontaminable
Overall dimensions weight bull 428times258times347 mm 115 kg
Continuous automatic monitoring of the gamma radiation flux Operation in the rocks ore liquid media and sludge
Physical characteristics bull detector ndash NaI (Tl) Oslash 18x30 mm
Measurement range bull 40 divide 8104 s-1cm-2
Energy range bull 01divide 30 MeV
Temperature rangebull minus 40 divide +50 degC
Electrical characteristics bull Interfaces RS-485
Mechanical characteristics bull Protection index
Ř BDKG-100 IP 68 Ř Interface block BS-16 IP 65
bull Paint stainless steel bull Overall dimensions weight
Ř Detector unit BDKG-100 Oslash 38times530 mm 3 kg Ř Interface block BS-16 176times80times64 07 kg
Radiation monitoring system SPC ldquoDozardquo
16 17
UDG-1B NOBLE GAS MONITOR
Continuous automatic monitoring of the beta-emit-ting radioactive gases concentration in the working air and in the air in ventilation ducts and stacksbull Gamma background compensation bull Audible and visual alarm signals of the excess of
preset thresholds bull Periodic calibration by means of standard beta-
source
Physical characteristicsbull Silicon detectors (2 pcs for measurement and for
background compensation)bull Air flow rate 10 divide 100 lminbull Operation temperature range minus 10 divide +50 ordmС
Measurement range bull 104 divide 6109 Bqm3
Energy range bull 008 divide 30 MeV
Electrical characteristicsbull Power supply 85 divide 260 V 47 divide 440 Hzbull Interfaces RS-232 2timesRS-485 Ethernetbull programmable relay output (SPDT relay)bull Analog output 4-20 mA (optional)
Mechanical characteristicsbull Protection index IP 65bull Paint decontaminable
Overall dimensions weight bull Stationary version 395times240times304 mm 295 kgbull Mobile version with pump unit BN-1
395times468times950 mm 543 kg
Alarmbull Sound alarm 80 divide 100 dBA at distance 1 mbull Visual alarm green yellow red
Mobile version with pump unit BN-1
Stationary version
Reference standards Nuclear IEC 60761 IEC 62302 EMC IEC 61010 IEC 61000-6-2 Seismic IEC 60980
bull Connection of the external alarm unit ldquoBASrdquo type
Versionsbull Stationary versionbull Stationary version with pump unit BN-1bull Mobile version with pump unit BN-1
UDA-1AB PARTICULATE MONITOR
Stationary version
Continuous automatic monitoring of the alpha- and beta- radioactive aerosol concentration in the work-ing air and in the air in ventilation ducts and stacksbull Radon toron progenies and gamma background
compensation bull On line alpha spectrometrybull Audible and visual alarm signals of the excess of
preset thresholds bull Control of electromagnetic valves when operating
with the external air sampling linebull Control of pump unit bull Periodic calibration by means of standard beta-
and alpha-sources
Physical characteristicsbull Silicon specrometric detectors (2 pcs for measure-
ment and for background compensation)bull Filter tape types LFAS FSLWbull Tape consumption (when continuous operation)
10 m50 daysbull Air flow rate 10 divide 100 lmin bull Operation temperature range minus 10 divide +50 ordmС
Measurement range bull Alpha 10-2 divide 2105 Bqm3 bull Beta 10-1 divide 106 Bqm3
Energy range bull Alpha 30 divide 90 MeV bull Beta 005 divide 30 MeV
Electrical characteristicsbull Power supply 85 divide 260 V 47 divide 440 Hzbull Interfaces RS-232 2timesRS-485 Ethernet bull Programmable relay output (SPDT relay)bull Analog output 4-20 mA (optional)
Mechanical characteristicsbull Protection index IP 65bull Paint decontaminable
Overall dimensions weight bull Stationary version 389times260times304 mm 156 kg bull Mobile version with pump unit BN-1
389times468times950 mm 384 kg
Alarmbull Sound alarm 80 divide 100 dBA at distance 1 mbull Visual alarm green yellow redbull Connection of the external alarm unit ldquoBASrdquo type
Versionsbull Stationary versionbull Stationary version with pump unit BN-1bull Mobile version with pump unit BN-1
Reference standards Nuclear IEC 60761 IEC 61172 EMC IEC 61010 IEC 61000-6-2 Seismic IEC 60980
Mobile version with pump unit BN-1
Radiation monitoring system SPC ldquoDozardquo
18 19
Physical characteristicsbull Scintillation detectors CsI(Tl) (2 pcs for measure-
ment and for background compensation)bull Cartridge activated charcoal
Measurement range bull 37 divide 37106 Bqm3
Energy range bull 006 divide 30 MeVbull Air flow rate 20 divide 40 lminbull Operation temperature range minus 10 divide +50 ordmС
Electrical characteristicsbull Power supply 85 divide 260 V 47 divide 440 Hzbull Interfaces RS-232 2timesRS-485 Ethernetbull Programmable relay output (SPDT relay)bull Analog output 4-20 mA (optional)
Mechanical characteristicsbull Protection index IP 65bull Paint decontaminable
Overall dimensions weight bull Stationary version 448times323times479 mm 35 kgbull Mobile version with pump unit BN-1
448times468times950 mm 578 kg
Reference standards Nuclear IEC 60761 IEC 61171 EMC IEC 61010 IEC 61000-6-2 Seismic IEC 60980
Alarmbull Sound alarm 80 divide 100 dBA at distance 1 mbull Visual alarm green yellow redbull Connection of the external alarm unit of ldquoBASrdquo
type
Versionsbull Stationary versionbull Stationary version with pump unit BN-1bull Mobile version with pump unit BN-1
Сontinuous automatic monitoring radioiodine concentration in the air at working places and in ventilation ducts and stacksbull Measurement of volumetric activity of radionu-
clides I-131 I-132 I-133 I-135 in the airbull On line gamma spectrometrybull Gamma background compensation bull Performance self-test by means of Am-241 check
source implanted into the detectorbull Audible and visual alarm signals of the excess of
preset thresholdsbull Periodic calibration by means of standard source
UDI-1B IODINE MONITOR
Physical characteristicsbull Silicon detector 2 pcs (for measurement and for
background rejection)bull Air flow rate 10 divide 100 lminbull Operation temperature range minus 10 divide +50 ordmС
Measurement range bull 104 divide 11010 Bqm3
Energy rangebull 006 divide 30 MeV
Electrical characteristicsbull Power supply 120 Vbull Interface RS-485
Mechanical characteristicsbull Protection index IP 65bull Paint decontaminable
Overall dimensions weight bull 474х246х243 mm 295 kg
UDG-03D NOBLE GAS MONITOR
Measurement of volumetric activity of beta-emitting radioactive gases (argon krypton xenon) adapted to the measurement of the rapidly changing volume activity in various technological processesbull Gamma background compensationbull Periodic calibration by means of standard beta-
source
Reference standards Nuclear IEC 60761 IEC 62302 EMC IEC 61010 IEC 61000-6-2 Seismic IEC 60980
Radiation monitoring system SPC ldquoDozardquo
20 21
Continuous automatic monitoring of steam genera-tor primary to secondary leakagebull On line gamma spectrometrybull N-16 monitoringbull Performance self-test by means of Am-241 check
source implanted into the detectorbull Audible and visual alarm signals of the excess of
preset thresholds
Physical characteristics
UDGP-01 STEAM GENERATOR LEAKAGE MONITOR
bull detector ndash scintillator CsI Oslash 40х100 mm
Measurement range bull High energy gamma-activity (N-16)
15bull103 divide 20bull108 Bqm3
bull General gamma-activity 10bull104 divide 20bull108 Bqm3
Energy range bull General gamma 005 divide 15 MeV bull in integral spectral band of energy
5000 divide 7200 keV bull temperature range minus 10 divide +80 ordmС
BOP-1SP
Electrical characteristicsbull Power supply 85 divide 260 V 47 divide 440 Hzbull Interfaces RS-232 RS-485 Ethernetbull programmable relay output (SPDT relay)
Mechanical characteristicsbull Protection index IP 65bull Paint decontaminable
Overall dimensions weight bull Detector unit Oslash 60x360 mm17 kgbull Data processing and transmission unit BOP-1sp
280x220x114mm 43 kgbull Collimator Oslash 350x455 mm 150 kg
Alarmbull Sound alarm 80 divide 100 dBA at distance 1 mbull Visual alarm green yellow redbull Connection of the external alarm unit of ldquoBASrdquo
type
Reference standards Nuclear IEC 61453 EMC IEC 61010 IEC 61000-6-2 Seismic IEC 60980Reference standards Nuclear IEC 60761 IEC 60710 IEC 60951-2 EMC IEC 61010 IEC 61000-6-2 Seismic IEC 60980
Ionization chambe 10 liters
UDGB-01T1
Physical characteristicsbull Detectors - stainless steel ionization chambersbull Air flow rate 10 divide 100 lminbull Operation temperature range minus 10 divide +50 ordmС
Volumes of ionization chambers bull UDGB-01T UDGB - 01T1 100 litersbull UDGB-01T2 01 liter
Measurement range (Kr-85) bull UDGB-01T UDGB-01T1 10104 divide 50109 Bqm3
bull UDGB-01T2 109 divide 501014 Bqm3
Measurement range (H-3) bull UDGB-01T UDGB-01T1 50104 divide 50109 Bqm3
bull UDGB-01T2 50109 divide 501014 Bqm3
Electrical characteristicsbull Power supply 85 divide 260 V 47 divide 440 Hzbull Interfaces RS-232 2timesRS-485 Ethernetbull Programmable relay output (SPDT relay)bull Analog output 4-20 mA (optional)
Mechanical characteristicsbull Protection index IP 23bull Paint decontaminable
Continuous automatic monitoring of the beta-emitting radioactive gases including tritium and carbon-14 concentration in the air at working places and in ventilation ducts and stacksbull Audible and visual alarm signals of the excess of
preset thresholds bull Monitoring of the noble gase activity in gaseous
effluents and ventilation air for accident and post-accident conditions
Overall dimensions weight bull UDGB-01T 381times343times716 mm 30 kgbull UDGB-01T1 260times320times175 mm 125 kgbull Ionization chamber 100 liters Oslash 250times600 mm
6 kgbull UDGB - 01T2 381times343times716 mm 27 kg
Alarmbull Sound alarm 80 divide 100 dBA at distance 1 mbull Visual alarm green yellow redbull Connection of the external alarm unit ldquoBASrdquo type
Versionsbull UDGB-01T - with built-in ionization chamber
100 litersbull UDGB-01T2 - with built-in ionization chamber
01 literbull UDGB-01T1 - with remote ionization chamber
100 liters
UDGB-01NOBLE GASESH-3C-14 MONITOR
Radiation monitoring system SPC ldquoDozardquo
22 23
Physical characteristicsLength of communication cablebull up to 1200 m
Character height bull ldquoImpuls-910-Rrdquo 100 mmbull ldquoImpuls-915-D4Srdquo 150 mmbull ldquoImpuls-927-D4Srdquo 270 mm
Operating temperature rangebull ldquoImpuls-910-Rrdquo 0 divide +50 ordmCbull ldquoImpuls-915-D4Srdquo ldquo-927-D4Srdquo minus 40 divide +50 ordmC
Electrical characteristicsbull Power supply 220 V 50 Hz
Mechanical characteristicsProtection index bull ldquoImpuls-910-R IP 44bull ldquoImpuls -915-D4Srdquo ldquo-927-D4Srdquo IP 65
Overall dimensions weight bull ldquoImpuls-910-Rrdquo 400times160times60 mm 3 kgbull ldquoImpuls -915-D4Srdquo 815times250times80 mm 5 kgbull ldquoImpuls -927-D4Srdquo 1250times330times80 mm 5 kg
ldquoIMPULSrdquoEXTERNAL DISPLAY UNIT
Display of data received from monitors of RMS
External display unit ldquoImpuls-910-Rrdquo
Reference standards EMC IEC 61010 IEC 61000-6-2 Seismic IEC 60980
Continuous monitoring of the flow rate temperature and humidity of the gas flowbull Definition of air volume flow rate in stacks taking
into account temperature and humidity of the air
UPPVM AIR FLOW PARAMETERS MONITOR
Physical characteristicsMeasurement range bull air flow velocity 1 divide 20 msbull air temperature 0 divide +80 ordmСbull air humidity 10 divide 95
Electrical characteristicsbull Power supply 220 V 50 Hz bull Interfaces RS-232 Ethernet
Mechanical characteristicsProtection index bull BSPP-1st BSPP-1tv BOP-1s IP 65bull PP-st IPTV IP 54bull Paint decontaminable
Overall dimensions weight bull air velocity probe PP-st 60times38times136 mm 015 kgbull Interface block BSPP-1st 125times155times73 mm 07 kgbull air temperature and relative humidity probe
IPTV-056-A 333times100times60 mm 07 kgbull Interface block BSPP-1tv 125times155times73 mm 07 kgbull Data processing and transmission unit BOP-1s
280x233x111 mm 8 kg
Reference standards Nuclear ISO 2889 EMC IEC 61010 IEC 61000-6-2 Seismic IEC 60980
BOP-1S
Radiation monitoring system SPC ldquoDozardquo
24 25
BASBAS-1S EXTERNAL ALARM
Generation of audible and visual signals of the excess of preset thresholds RMS monitorsbull Audible alarm 80 divide 100 dBA at distance 1 mbull Visual alarm green yellow red
Distance from RMS monitorbull BAS up to 20 mbull BAS-1s up to 1200 m
Power supply bull 220 V 50 Hz
Overall dimensions weight bull BAS 145times108times460 mm 18 kg bull BAS-1s 166times109times466 mm 18 kg
Reference standards EMC IEC 61010 IEC 61000-6-2 Seismic IEC 60980
Physical characteristicsLength of communication cablebull up to 1200 m
Displayed page size bull 4 lines of 20 characters
Volume of loaded information bull 10 pages
Change of pagesbull programmed or by pressing a button
Operating temperature rangebull minus 40 divide +50 ordmC
Electrical characteristicsbull Power supply 9 divide 18 VDCbull Interfaces RS-485
Mechanical characteristicsbull Protection index IP 65bull Overall dimensions weight 222times164times73 mm
40 kg
BI-2 REMOTE DISPLAY amp ALARM UNIT
bull Display of data received from monitors of RMSbull Audible and visual alarms on exceeding preset
thresholds of the RMS equipment bull Individual threshold setting for each measure-
ment channelbull Audible alarm 80 divide 100 dB at a distance of 1 m bull Visual alarm red yellow green
Reference standards EMC IEC 61010 IEC 61000-6-2 Seismic IEC 60980
Radiation monitoring system SPC ldquoDozardquo
2726
Electrical characteristicsbull Power supply 220 V 50 Hz bull Interfaces RS-232 RS-485 Ethernetbull programmable relay output (SPDT relay)
Alarmbull Sound alarm 80 divide 100 dBA at distance 1 mbull Visual alarm green yellow redbull Connection of the external alarm unit ldquoBASrdquo type
Related monitors and equipmentsbull UDA-1AB particulate monitorbull UDG-1B noble gas monitorbull UDI-1B iodine monitorbull UPPVM air flow parameters monitorbull Sampling and sample separation rack
Air flow parameters monitor rack
Reference standards Nuclear IEC 60761 IEC 61171 IEC 61172 IEC 62302 ISO 2889 EMC IEC 61010 IEC 61000-6-2 Seismic IEC 60980
Sampling and sample separation rack
Continuous monitoring of radioactivity in gaseous effluentsbull Automatic monitoring of the alpha- and beta-
radioactive aerosol noble gas and radioiodine concentrations in the air in ventilation ducts and stacks
bull Monitoring of the flow rate temperature and humidity of the gas flow
bull Separation of gaseous effluent into targeted fractions by means of a two-stage filter
bull Reversion of gas after analysis to the ventilation system
Physical characteristics
Particulate (UDA-1AB)bull Silicon specrometric detectors (2 pcs for measure-
ment and for gamma-background compensation) bull Filter tape types LFAS FSLWbull Tape consumption (when continuous operation)
10 m50 days
Measurement range bull Alpha 10-2 divide 2105 Bqm3 bull Beta 10-1 divide 106 Bqm3
Energy range bull Alpha 30 divide 90 MeV bull Beta 005 divide 30 MeV
Noble gas (UDG-1B)bull silicon detectors (2 pcs for measurement and for
gamma-background compensation)
Measurement range bull 104 divide 6109 Bqm3
Energy range bull 008 divide 30 MeV
Iodine (UDI-1B)bull scintillation detectors CsI(Tl) (2 pcs for measure-
ment and for background compensation)
SKGAV STACK MONITOR
Particulate noble gas and iodine monitors rack
Measurement range bull 37 divide 37105 Bqm3
Energy range bull 015 divide 30 MeV
Air flow parameters (UPPVM)Measurement range bull air flow velocity 1 divide 20 msbull air temperature 0 divide +80 ordmСbull air humidity 10 divide 95
Radiation monitoring system SPC ldquoDozardquo
28 29
CONFIGURATOR SOFTWAREMaintenance and set-up softwarebull Set-up and verify RMS monitorsbull Control testing adjustment and repair of RMS
monitorsbull Monitors measurement results archive receive
and View bull Communication through RS-232
RMS WORKSTATION ndash OPERATOR CONSOLEOrganization of interaction of the RMS Server and Monitors
Single monitor console includes vandal-proof key-board amp UPS
Reference standard IEC 61559-1 IEC 61559-2
RMS SOFTWAREData acquisition storing and visual representation RMS monitors measurement resultsbull Ethernet IEEE 8023 networkbull Clientserver architecturebull TCPIP protocolbull Oracle based Data Basebull Supremal by means InSat MasterSCADA
Radiation monitoring system SPC ldquoDozardquo
30 31
Delivery setComposition and modification depend on the tasks to be solved using the RM Rack
The rack which is an integral part of RM Rack accommodatesbull Monitors UDA-1AB UDG-1B UDG-03D UDI-1B
UDGB-01Tbull DBG-S11D Wide range gamma area monitor
BDMG-101 High range gamma area monitor UDMN-100 Neutron area monitor BDRG-52R High range gamma area monitor
bull BI-2 Remote display amp alarm unitbull Pump unit BN-01bull Data processing and transmission unit BOP-1Mbull External alarm BAS or BAS-1sbull Equipment of sampling line (flow meters ball
valves filter holder piping solenoid valve)bull Switchboard (intended for switching of all equip-
ment and transfer of data to the upper level via the unified communication channel)
RM RACK RADIATION MONITORING RACK
The radiation monitoring rack (RM Rack) is designed for continuous monitoring of radiation parameters in premises and technological systems at nuclear facil-ities RM Rack can be used as a structural element of the lower-level of RMS at nuclear power plants and other nuclear facilities that involved in obtaining processing use and storage of radioactive materials
FeaturesContinuous automatic monitoring of the alpha- and beta- radioactive aerosol beta-emitting radioactive gases and radioiodine concentrations in the working air and in the air in stacks and others radiation parameters in the facilities
The stand providesbull Primary processing storage and transmission of
measured and related data into the information channel based on the Ethernet IEEE 8023 inter-face (TCPIP protocol)
bull Transfer of required data to the location where the equipment is installed via technological channels based on RS-232 interface
bull Generation of audible and visual warning alarm signals when the preset thresholds are exceeded
bull Display of received data on the LCD
Radiation monitoring system SPC ldquoDozardquo
32 33Reference standards IEC 60860 ANSIANS-83 ISO 7753
Purposebull Detection and recording of criticality accident
(CA) by measuring the absorbed dose rate of gamma-neutron radiation in the premises of monitored object its comparison with a threshold value and generation of audible and visual signals
bull Automatic collection processing storage and display of measurement data and related infor-mation as visual and graphical representation for operators of nuclear safety service
Functions of the systembull Detection and recording of CA events by con-
tinuous measurement of absorbed dose rate of gamma radiation comparison of measured values with preset thresholds generation of signals to activate the alarm
bull Activation of audible visual alarmbull In the event of CA turning on warning signals
ldquoDO NOT ENTERrdquo at illuminated information pan-els placed at the entrances to the controlled area
Featuresbull Data can be transferred to external data commu-
nication channel using RS-485 interface (DiBus data exchange protocol)
bull Automatic self-testing of detection units BR-04D with display of information about the type of fault
bull Possibility for connecting additional a detection and alarm units
bull Ability to function in general regardless of the functioning of components within the agreed scope of nuclear safety tasks
bull Radiation hardness up to 100 Gy
SRKS-01DCRITICALITY ACCIDENT ALARM SYSTEM
Features of softwarebull Collection of information via RS-485 network
displaying it on the PC monitor transmission to remote users archiving and storage
bull Status monitoring and display of values measured by BR-04D and DBG-S11D in locations as per layout of premises
bull Access to archived data with possibility to gener-ate reports for periods determined by operator
bull Maintenance and archiving of a log of dosimetric measurements data and events along with their time stamps
bull Possibility to transfer data to external users via Ethernet network for integrating of CA into higher level systems
Basic complete setLower level bull Control unit with power supplybull BR-04D detection unitsbull BZS-01D audible alarm unitsbull BSS-01D visual alarm unitsbull SIT-01D illuminated warning signsbull PBZ panels for muting audible alarmbull Network communication module
Additional lower layer devicesbull DBG-S11D wide range gamma area monitor
Upper layer bull CDP central display panelbull Service workstation
RS-485
RS-485
RS-4
85
Audible alarm units BZS-01D
Illuminated warning signs SIT-01D
Detection units BR-04D
Network communication
moduleDBG-S11D wide range gamma area monitor
Panels for muting audible alarm
Control unit with power supply
Visual alarm units BSS-01D
RS-485
RS-485
RS-4
85
Audible alarm units BZS-01D
Illuminated warning signs SIT-01D
Detection units BR-04D
Network communication
moduleDBG-S11D wide range gamma area monitor
Panels for muting audible alarm
Control unit with pow-er supply
Visual alarm units BSS-01D
RS-485
RS-4
85
Audible alarm units BZS-01D
Illuminated warning signs SIT-01D
Detection units BR-04D
Network communication
moduleDBG-S11D wide range gamma area monitor
Panels for muting audible alarm
Control unit with power supply
Visual alarm units BSS-01D
RS-485
RS-485
RS-4
85
Audible alarm units BZS-01D
Illuminated warning signs SIT-01D
Detection units BR-04D
Network communication
moduleDBG-S11D wide range gamma area monitor
Panels for muting audible alarm
Control unit with power supply
Visual alarm units BSS-01D
Ethernet
Central display panel Service workstation
RS-485
RS-485
RS-4
85
BZS-01D audible alarm units
SIT-01D illuminated warning signs
BR-04D detection units
Network communication
moduleDBG-S11D wide range gamma area monitor
PBZ panels for muting audible alarm
Control unit with power supply
BSS-01D visual alarm units
Radiation monitoring system SPC ldquoDozardquo
34 35
ldquoBREEZErdquoHIGH-VOLUME AIR SAMPLER
Physical characteristicsbull Measurement range of air flow rate
250 divide 1200 m3hbull Continuous operation time not less than 24 h
Filter materialsbull High-purity glass fiberbull Pure quartz or cellulosebull Filter fabric FPP-15-15
Electrical characteristicsPower supply bull 220380 V 50 Hz
Interfaces bull RS-485bull Ethernetbull GSMGPRS (option)
Environmental characteristicsTemperature range bull minus 40 divide + 40 ordmC
Relative humidity limit at 35 ordmC bull 95
Atmospheric pressure range bull 840 divide 1067 kPa
Versionsbull Standalone unit bull Part of Environmental Radiation Monitoring
System (ERMS)
Type of detection unitsbull Beta block BDZB-100Lbull DBG-S11D wide range gamma area monitorbull Scintillation spectrometric block
The motor of Air Sampler is controlled by an electronic flow sensor that detects changes in the operators pre-set flow rate caused by changes in temperature barometric pressure and pressure drop due to dust loading on filter media It compensates for these changes by adjusting the motor speed to maintain the pre-set flow ratebull Measurement of parameters of ionizing radiation bull Standalone mode of operation or as the part
of Environmental Radiation Monitoring System (ERMS)
Purposebull Environmental Radiation Monitoring System
(ERMS) in the control and buffer areas of the radia-tion and nuclear facilities
Referencesbull Since the year 2000 the system is successfully
operating the ERMSs at 8 Russian nuclear power plants (about 180 monitoring stations)
bull Since the year 2005 the ERMS is operating in the Moscow (about 40 monitoring stations)
bull Since the year 2005 the regional ERMS is under operation in several Russian Federation regions
Basic complete setMonitoring stations bull Data processing and transmission unit BOP-1TA bull Gamma area monitor DBG-S11D
Central data processing station (CDPS)bull Data processing and transmission unit BOP-1TAbull Server
By requestbull Emergency Response and Crisis Management
Centers for enterprisesbull Regional Emergency Response and Crisis Manage-
ment Centersbull rdquoBreezerdquo High-Volume Air Samplerbull Mobile lab with gamma-survey system rdquoGammandash
sensorrdquo
ldquoATLANT-MrdquoENVIRONMENTAL RADIATION MONITORING SYSTEM
Monitoring system for the continuous radiation monitoring of territories and facilities with the data transmission GSMGPRS network
Data transmission bull GSMGPRS
Power supply bull 220 V 50 Hz
Continuous autonomous operation (at 20 ordmC)bull From built-in battery not less than 5 hoursbull From external battery not less than 24 hours
Operation temperature bull Minus 40 divide +50 ordmC
Operation humidity bull Up to 98
Protection bull IP65
Reference standards Nuclear IEC 61017-11991 IEC 61017-21994
36
Radiation Monitoring Equipment
bull Localization of radioactive contaminationsbull Database with dose rate contaminations
spectra measurement date amp time coordi-nates
bull Work as part of mobile laboratory or as part of Environmental Radiation Monitoring System with real-time data transfer
Physical characteristicsDetector bull Scintillation NaI (Tl) GM counters
Measurement rangebull 01 ndash 107 μSvh
Energy range bull 005 ndash 3 MeV
Operation temperature range bull minus 10 divide +50 ordmС
Electrical characteristics bull Power supply 220 V 50 Hz
ldquoGAMMAndashSENSORrdquoGAMMA-SURVEY SYSTEM
SPC ldquoDozardquoRadiation monitoring equipment
38 39
AREA MONITOR ldquoFREGATrdquoArea Monitor ldquoFregatrdquo is designed for building rela-tively simple and inexpensive radiation monitoring systems at such facilities as radionuclide sources storage areas isotope products warehouses nuclear medicine departments PET centers calibration laboratories where sources of ionizing radiation are used etc
Small scale automated radiation monitoring systems built with ldquoFregatrdquo components featuring audible and visual alarms are matched suitable to meet the regulatory radiation safety requirements
Area monitor ldquoFregatrdquo requires virtually no adjust-ment it is simple and convenient for installation and operation
BPI-1D LOCAL DISPLAY UNIT
Display of monitored parameters values received from external measuring devices
Purposebull Processing and display of values of monitored
parameters on information panel bull Comparison of values of monitored parameters
with thresholdsbull Transfer of monitored parametersrsquo values to
networkbull Generation of alarm in case of exceeding of preset
thresholds including external alarm devices
FeaturesTesting the unit and connected devicesbull Visually on the panelbull Using adjustment software when connected to
PC via USB
Automatic self-testing
The panel displays the following informationbull Diagnostic information about the status of con-
nected devicesbull Current date and timebull Values of measured parametersbull Position of measured values with respect to the
thresholds in the form of scales with green yellow and red zones
bull Time history (trend) for each measured value
Physical characteristicsTemperature range bull minus 10 divide + 50 ordmC
Maximum number of connected devicesbull measuring devices 15bull external audible and visual alarm 15
Display diagonal bull 152 cm (6)
Electrical characteristicsbull Interfaces RS-485bull Power supply 220 V 50 Hz 12 divide 24 V
Mechanical characteristicsbull Protection index IP54bull Paint decontaminable
Overall dimensions weightbull 296x248x118 mm 5 kg
DBG-S11D wide range gamma area monitor
UDMN-100 neutron area monitor
Ethernet RS-485
UDKS-100 gamma and X-ray area monitor
BPI-1D Local display unit
BAS-2 ldquoMicrordquo external visual alarm
BZS-2 ldquoMicrordquo external audible alarm
ldquoImpulsrdquo external display unit
Service workstation
Illuminated warning signs
SPC ldquoDozardquoRadiation monitoring equipment
4140
Continuous automatic monitoring of the gamma- X-ray ambient dose equivalent rate
Physical characteristicsbull Detector tissue-equivalent plastic scintillator
Oslash 45times20 mm
Measurement range bull Dose rate measurement range 01 μSvh divide 1 Svh bull Energy range 0015 divide 10 MeV
Mechanical characteristicsbull Protection index IP65bull Paint decontaminable
Overall dimensions weightbull Oslash72times265 mm 15 kg
UDKS-100 GAMMA AND X-RAY AREA MONITOR
UDMN-100 NEUTRON AREA MONITOR
Physical characteristicsbull detector ndash scintillator ZnS(Ag) Li-6
Measurement range bull 01 μSvh divide 01 Svh
Energy range bull 0025 eV divide 100 MeV
Temperature range bull minus 45 divide +50 ordmC
Electrical characteristicsbull Interfaces RS-485
Mechanical characteristicsbull Protection index IP 65bull Paint decontaminable
Overall dimensions weight bull 428times258times347 mm 115 kg
Continuous automatic monitoring of the neutron-radiations ambient dose equivalent ratebull Spherical polyethylene moderator Oslash 239 mm
MEASURING UNITS
DBG-S11D WIDE RANGE GAMMA AREA MONITOR
Continuous automatic monitoring of the gamma- ambient dose equivalent rate
Physical characteristicsbull Detector ndash GM counters
Measurement rangebull DBG-S11D 01 μSvh divide 10 mSvhbull DBG-S11D-01 01 μSvh divide 10 Svhbull DBG-S11D-02 01 μSvh divide 100 Svh
Energy rangebull 005 divide 30 MeV
Temperature range bull minus 40 divide +50 ordmC
Electrical characteristicsbull Interfaces RS-485 USB
Mechanical characteristicsbull Protection index IP 68bull Paint decontaminable
Overall dimensions weightbull DBG-S11D Oslash 68times141 mm 065 kg bull DBG-S11D-01 Oslash 68times179 mm 07 kgbull DBG-S11D-02 Oslash 68times179 mm 07 kg
Versionsbull DBG-S11Dbull DBG-S11D-01bull DBG-S11D-02
Reference standards Nuclear IEC 60846 IEC 60532 EMC IEC 61010 IEC 61000-6-2 Seismic IEC 60980
SPC ldquoDozardquoRadiation monitoring equipment
4342
ALARM UNITS
Generation visual signals of the excess of preset thresholds
Physical characteristicsLength of communication cablebull up to 1200 mbull Alarm Visual alarm green yellow red
Electrical characteristicsbull Power supply +12 V
Mechanical characteristicsbull Protection index IP 23
Overall dimensions weight 160times84times41 mm 02 kg
BAS-2 ldquoMICROrdquo EXTERNAL VISUAL ALARM
Generation audible signals of the excess of preset thresholds
Physical characteristicsLength of communication cablebull up to 1200 mbull Audible alarm 80 divide 100 dB at a distance of 1 m
Electrical characteristicsbull Power supply +12 V
Mechanical characteristicsbull Protection index IP 23
Overall dimensions weight 160times84times41 mm 02 kg
BZS-2 ldquoMICROrdquo EXTERNAL AUDIBLE ALARM
Physical characteristicsLength of communication cablebull up to 1200 m
Electrical characteristicsbull Power supply 220 V 50 Hz
Mechanical characteristicsbull Protection index IP 23
Overall dimensions weight bull 330times110times20 mm 05 kg
Physical characteristicsLength of communication cablebull up to 1200 m
Character height bull ldquoImpuls-910-Rrdquo 100 mmbull ldquoImpuls-915-D4Srdquo 150 mmbull ldquoImpuls-927-D4Srdquo 270 mm
Operating temperature rangebull ldquoImpuls-910-Rrdquo 0 divide +50 degCbull ldquoImpuls-915-D4Srdquo ldquo-727-D4Srdquo minus 40 divide +50 degC
Electrical characteristicsbull Power supply 220 V 50 Hz
Mechanical characteristicsProtection index bull ldquoImpuls-910-R IP 44bull ldquoImpuls-915-D4Srdquo ldquo-727-D4Srdquo IP 65
Overall dimensions weight bull ldquoImpuls-910-Rrdquo 400times160times60 mm 3 kgbull ldquoImpuls-915-D4Srdquo 815times250times80 mm 5 kgbull ldquoImpuls-927-D4Srdquo 1250times330times80 mm 5 kg
ILLUMINATED WARNING SIGNS
ldquoIMPULSrdquo EXTERNAL DISPLAY UNIT
SPC ldquoDozardquoRadiation monitoring equipment
4544
Individual threshold setting for each measurement channel
Continuous area and process monitoring
Collect amp display data from two measurement chan-nels (units with RS-485 or analog pulses)
Audible and visual alarms on exceeding preset thresholds or status of connected devices
Individual threshold setting for each measurement channel
Switching on the external alarm or executive devices when any threshold is exceeded
The wide panel displays the following information bull Values of measured parameters as min-1∙cm-2
s-1∙cm-2 μSvhbull Diagnostic information about the status of con-
nected devicesbull Current date and timebull Position of measured values with respect to the
thresholds in the form of scales with green yellow and red zones
bull Time history (trend) for each measured value
Physical characteristics Measurement range bull Count rate up to 107 CPM (170 kHz)
Operating temperature range bull minus 20 divide +50 ordmC
Electrical characteristics bull Power supply 220 V bull Interfaces USB
Mechanical characteristics bull Protection index IP 65 bull Overall dimensions weight 222times164times73 mm
40 kg
UIM-3D AREA MONITOR COUNT RATE METER
Measurement of alpha radiation flux density
Detector unit BDZA-100 (70 cm2) Measurement range 01 divide 104 min-1∙cm-2
Detector unit BDZA-100B (300 cm2) Measurement range 01 divide 2103 min-1∙cm-2
Measurement of beta radiation flux density
Detector unit BDZB-100 (28 cm2) Measurement range 10 divide 105 min-1∙cm-2
Detector unit BDZB-100L (30 cm2) Measurement range 10 divide 104 min-1∙cm-2
Detector unit BDZB-11D (84 cm2) Measurement range 5 divide 15∙104 min-1∙m-2
OPTIONAL PROBESMeasurement of gamma radiation flux density
Detector units BDEG-03 Measurement range 4 divide 2000 s-1∙cm-2
Detector unit UDKG-100 for operation in the rocks ore liquid media and sludge Measurement range 40 divide 8000 s-1∙cm-2
Measurement of the ambient dose equivalent rate
Detector unit DBG-S11D Measurement range 01 μSvh divide 100 Svh
Measurement of neutron radiation ambient dose equivalent rate
Detector unit BDMN-100 Measurement range 01 μSvh divide 01 Svh
SPC ldquoDozardquoRadiation monitoring equipment
46 47Reference standards Nuclear IEC 61526
Measurement of gamma-radiation personal dose equivalent Hp(10)bull Stand-alone dosimeter or composed of dosimetric
system onebull Audible and visual alarmbull Large memory dose accumulation historiesbull Exclusion of unauthorized intervention in dosim-
etry operation
DKG-05D PERSONAL GAMMA DOSIMETER
Physical characteristicsDetectors bull Silicon
Measurement range bull Dose rate 1 μSvh divide 10 Svhbull Dose 01 μSv divide 15 Sv
Energy range bull 005 divide 30 MeV
Electrical characteristicsbull Power supply rechargeable NiMH battery 1
alcaline battery (type AAA)
Operation timebull Till recharging not less 400 hoursbull With one set batteries not less 1000 hours
Mechanical characteristicsOverall dimensions weight bull 47times26times87 mm (with clip) 70 g
Environmental characteristicsbull IP65bull Temperature range minus 20 divide +45 ordmCbull Humidity up to 98 at 35 ordmCbull Shock vibration and drop resistant
Alarmbull Excess of alarm thresholdsbull Warnings of self-test failure and battery discharge bull Audible alarm 80 dB at 40 cmbull Visual alarm blinking LED
Relative equipmentbull One dosimeter charger ZU-1Mbull Chargestorage cassetes KZU-28KZU-56bull ldquoSmart chargingrdquo feature extends battery life timebull DKG-05D reader US-05bull DKG-05D system reader DVS-01D
Reader-PC interfacebull US-05 USB bull DVS-01D Ethernet
KZU-28
Physical characteristicsDetectors bull Silicon Li-6
Gamma measurement range bull Dose rate 1 μSvh divide 10 Svhbull Dose 01 μSv divide 15 Sv
Gamma energy range bull 005 divide 60 MeV
Neutron measurement range bull Dose rate 1 μSvh divide 2 Svhbull Dose 20 μSv divide 15 Sv
Neutron energy range bull 0025 eV divide 20 MeV
Electrical characteristicsPower supply bull Rechargeable NiMH batterybull Operatiion time till recharging not less 200 hours
Mechanical characteristicsOverall dimensions weight bull 47times26times87 mm (with clip) 70 g
Environmental characteristicsbull IP65bull Temperature range minus 20 divide +40 ordmCbull Humidity up to 75 at 30 ordmCbull Shock vibration and drop resistant
Alarmbull Excess of alarm thresholds bull Warnings of self-test failure and battery discharge bull Audible alarm 80 dB at 40 cmbull Visual alarm blinking LED
Relative equipmentbull One dosimeter charger ZU-1Mbull Chargestorage cassetes KZU-28 KZU-56bull ldquoSmart chargingrdquo feature extends battery life timebull DVS-02D reader UZS-01Sbull DVS-02D system reader DVS-01D
Reader-PC interfacebull UZS-01S USB bull DVS-01D Ethernet
UZS-01DReference standards Nuclear IEC 61526
DVS-02D GAMMA-NEUTRON PERSONAL ELECTRONIC DOSIMETER
Measurement of gamma- and neutron radiations personal dose equivalent Hp(10)bull Stand-alone dosimeter or composed of dosimetric
system onebull Audible and visual alarmbull Large memory dose accumulation historiesbull Exclusion of unauthorized intervention in dosim-
etry operationbull Both albedo thermal neutrons and intermediate
fast neutrons registrationbull Usable in the fields of Pu(Be) Po(Be) Cf and other
neutron sources as well as near nuclear reactors without neutron spectrum estimation
SPC ldquoDozardquoRadiation monitoring equipment
48 49
Dosimeters DVG-03D
DVGI-8D NEW PEN-TYPE PERSONAL IONIZATION CHAMBER DOSIMETERS
Measurement of personal dose equivalent Hp(10) of gamma and X-ray radiationbull Hp(10) of continuous and pulsed gamma and
X-ray radiation bull Electronic reader KSU-1bull Dosimeter DVG-03D with electronic ID bull Personal dose histories in the readerrsquos memorybull Readerrsquos connection with PC for database main-
tenance
Physical characteristicsDetector bull Ionization chamber
Measurement range bull 001 mSv divide 25 mSv
Energy range bull 0015 divide 25 MeV
Temperature range bull Reader KSU-1 +10 divide +50 ordmСbull Dosimeter DVG-03D minus 40 divide +50 ordmС
Electrical characteristicsPower supply bull Reader KSU-1 220 V 50 Hz built-in batteries bull Dosimeter DVG-03D four batteries CR 1025 bull Batteries life 3 yearsbull Readers interfaces RS-232USB 20
Mechanical characteristicsOverall dimensions weightbull Dosimeter DVG-03D Oslash 18times126 mm 005 kgbull Reader KSU-1 235times232times125 mm 28 kg
Reference standards Nuclear IEC 62387-1
DKG-02U ldquoARBITERrdquo WIDE RANGE GAMMA-DOSIMETER
Physical characteristicsDetectors bull GM counters
Measurement rangebull Dose-rate 01 μSvh divide 3 Svhbull Dose 1 μSv divide 100 Sv
Energy range bull 005 divide 3 MeV
Electrical characteristicsbull Power supply 2 alcaline batteries (type AA)bull Batteries life not less 200 hours
Mechanical characteristicsOverall dimensions weight bull 152times82times32 mm 03 kg
Environmental characteristicsbull Temperature range minus 20 divide +50 ordmCbull Humidity up to 90 at +25 ordmCbull Shock vibration and drop resistant
Reference standards Nuclear IEC 60846
Measurement of gamma radiation ambient equiva-lent dose H(10) and dose rate H(10)bull Audible signals (clicks) for radiation condition
estimationbull Analog scale for search modebull Audible and visual alarms of the excess of preset
dose and dose rate thresholds bull Shock-resistant water-proof easy decontamina-
tion casebull 100 measurement results memory with date and
time of measurementbull Indication of total dose accumulated during
exploitation time bull Indication of measurement result statistical
uncertainty
SPC ldquoDozardquoRadiation monitoring equipment
50 51
Physical characteristicsDetectors bull GM counter
Measurement rangebull Dose-rate 01 μSvh divide 3 mSvhbull Dose 1 μSv divide 02 Sv
Energy range bull 005 divide 3 MeV
Temperature range bull Minus 20 divide +50 ordmC
Electrical characteristicsbull Power supply 2 alcaline batteries 15 V (type AA)bull Batteries life not less 200 hours
Mechanical characteristicsOverall dimensions weight bull 122times74times29 mm 025 kg
Reference standards Nuclear IEC 60846
DKG-07D ldquoDROZDrdquoGAMMA-DOSIMETER
Measurement of gamma radiation ambient equiva-lent dose H(10) and dose rate H(10)bull Two independent measurement channels dose
and dose ratebull Audible signals (clicks) for radiation condition
estimationbull Continuous measurement with updating meas-
urement resultbull Measurement result can be obtained with any
desired statistical uncertainty (error)bull Automatic restart when radiation level sharply
changesbull Indication of statistical uncertainty (error) during
measurement process
Continuous measurement with updating measure-ment result
Automatic restart when radiation level sharply changes bull Gamma dose H(10) and dose-rate H(10) meas-
urementbull Beta and gamma contamination surveybull Indication of statistical uncertainty during the
measurementbull Continuous measurement with accuracy increas-
ing with time bull Automatic restart triggered by change of gamma
dose-ratebull Compensation of gamma count rate while meas-
uring beta radiationbull Indication of battery charge levelbull Audible signal of the excess of preset threshold
Physical characteristicsDetectors bull GM counter
Measurement range bull Dose-rate 01 microSvh divide 20 mSvhbull Dose 1 microSv divide 100 Svbull Beta flux density (for Sr-90+Y-90)
10 divide 105 cm-2 min-1
Energy range bull Gamma 005 divide 3 MeVbull Beta 01 divide 3 MeV
Temperature range bull Minus 20 divide +50 ordmC
MKS-15D ldquoSnegirrdquo backside
MKS-15D ldquoSNEGIRrdquoMULTI ndash PURPOSE RADIATION SURVEY METER
Reference standards Nuclear IEC 60846 IEC 60325
Electrical characteristicsbull Power supply 2 alcaline batteries (type AA)bull Battery life not less 400 hours
Mechanical characteristicsOverall dimensions weight bull 124times72times35 mm 035 kg
SPC ldquoDozardquoRadiation monitoring equipment
52 53
Physical characteristicsDetectorbull GM counter
Measurement range bull 01 μSvh divide 20 mSvh
Energy range bull 005 divide 30 MeV
Threshold setting range bull 03 μSvh divide 20 mSvh
Step change of the thresholdbull In the range 03 divide 10 μSvh with the step
001 μSvhbull In the range 10 divide 100 μSvh with the step
01 μSvhbull In the range 100 divide 2000 μSvh with the step
10 μSvh
Electrical characteristicsPower supply bull 220 V 50 Hz bull Relay output
Mechanical characteristicsProtection index bull IP 40
Overall dimensions weight bull 226times120times75 mm 07 kg
Alarmbull Sound alarm 80 divide 100 dBA at distance 1 mbull Visual alarm redbull Connection of the external alarm signaling unit
Reference standards Nuclear IEC 60846 IEC 60532
Continuous automatic monitoring of the ambient dose equivalent rate bull Measurement of gamma dose rate H(10)bull Audible and visual alarm signals for preset
thresholdsbull Switching on the external signaling or executive
devices
SRPS-05D GAMMA MONITOR
Measurement ofbull Gamma and X-ray personal dose equivalent
Hp(10)bull Neutron personal dose equivalent Hp(10)bull Lens dose equivalent Hp(3)bull Skin dose equivalent Hp(007)bull TLD reader day-to-day tests using built-in LEDbull No needs nitrogen for heating
Physical charachteristicsDetectors bull 7LiF Mg Ti (gamma beta)bull 6LiF Mg Ti (neutron)
Gamma and X-ray Hp(10) Measurement range bull 500 μSv divide 10 Sv
Energy range bull 0015 divide 30 MeV
Neutron Hp(10)Measurement range bull 01 mSv divide 100 mSv
Energy range bull 0025 eV divide 10 MeV
Beta and photons Hp(007) Hp(3) Measurement range bull 2 mSv divide 100 Sv
Energy range bull Beta 025 divide 35 MeVbull Photons lt15 keV
Mechanical characteristicsDosimeters overall dimensions weight bull Gamma Hp(10) DTL-2 holder - 62times26times16 mm
16 gbull DTU holder - 42times28times18 mm 8 gbull Lens Hp(3) face skin Hp(007) Oslash 32times16 mm 9 gbull Finger skin Hp(007) 90times20times2 mm 1 gbull Neutron gamma Hp(10) 48times40times20 mm 30 g
Reference standards Nuclear IEC 61066
DTL-2 DTU-2
MKD (A-type) DVNG-M
DOZA-TLD MULTIPURPOSE TLD SYSTEM
SPC ldquoDozardquoRadiation monitoring equipment
54 55
Continuous and pulsed gamma and X-ray dose H(10) and dose-rate measurementbull Alpha beta and gamma contamination surveybull Neutron dose H(10) and dose-rate measurementbull Gamma radiation flux density in boreholes and
liquid media measurement
Electrical characteristicsPower supply bull UIK-05 four C-size batteriesbull UIK-05-01 rechargeable batterybull UIK-06 rechargeable battery
Interfaces bull RS-232bull USB (via adapter)
bull Detector type automatic determination and corre-sponding measurement modes selection
bull Alarm threshold settings ndash for dose dose-rate alpha and beta contaminations
bull ldquoDetectrdquo and ldquoLocaterdquo modes for survey probes
Reference standards Nuclear IEC 60846 IEC 60325 IEC 61005 IEC 62363
Case
UIK-06 control unit165times78times48 mm 03 kg
DKS-96UNIVERSAL RADIATION SURVEY METER
UIK-05 control unit202times86times90 mm 10 kg
BDZA-96
BDZA-96B
BDZA-96M
BDZA-96S
BDZA-96T
EXTERNAL PROBES ALPHAALPHA BDZA-96Detector bull ZnS(Ag) 70 cm2
Measurement range (for Pu-239)bull 01 divide 104 min-1cm-2
Overall dimensions weightbull Oslash 130times240 mm 11 kg
ALPHA BDZA-96BDetector bull ZnS(Ag) 300 сm2
Measurement range (for Pu-239)bull 01 divide 2103 min-1cm-2
Overall dimensions weightbull Oslash 230times290 mm 40 kg
ALPHA BDZA-96MDetector bull ZnS(Ag) 10 сm2
Measurement range (for Pu-239)bull 01 divide 105 min-1cm-2
Overall dimensions weightbull Oslash 65times240 mm 09 kg
ALPHA BDZA-96SDetector bull ZnS(Ag) 30 сm2
Measurement range (for Pu-239)bull 01 divide 5104 min-1cm-2
Overall dimensions weightbull Oslash 90times240 mm 10 kg
ALPHA BDZA-96TDetector bull Silicon 5 сm2
Measurement range (for Pu-239)bull 01 divide 106 min-1cm-2
Overall dimensions weightbull Oslash 50times60 mm 015 kg
SPC ldquoDozardquoRadiation monitoring equipment
56 57
BETA BDZB-96Detector Scintillator 28 сm2
Measurement range (for Sr-90+Y-90)bull 10 divide 105 min-1cm-2
Energy rangebull 03 divide 30 MeV
Overall dimensions weightbull Oslash 90times230 mm 09 kg
BETA BDZB-99Detector bull GM counter 30 сm2
Measurement range (for Sr-90+Y-90)bull 20 divide 104 min-1см-2
Energy rangebull 012 divide 30 MeV
Overall dimensions weightbull Oslash 88times80 mm 04 kgbull Telescopic pole length 07 m
BETA BDZB-96BDetector bull GM counter 80 сm2
Measurement range (for Sr-90+Y-90)bull 3 divide 104 min-1сm-2
Energy rangebull 012 divide 30 MeV
Overall dimensions weightbull 150times200times110 mm 15 kg
BETA BDZB-96Sbull Detector GM counter 15 сm2
Measurement range (for Sr-90+Y-90)bull 10 divide 3104 min-1cm-2
Energy rangebull 012 divide 30 MeV
Overall dimensions weightbull Oslash 65times65 mm 03 kgbull Telescopic pole length 07 m
BDZB-96
BDZB-99
BDZB-96B
BDZB-96S
EXTERNAL PROBES BETA
GAMMA BDKS-96BDetector bull Tissue-equivalent scintillator Oslash 45times20 mm
Measurement rangebull Dose rate H(10) 01 μSvh divide 1 Svhbull Dose H(10) 01 μSv divide 10 Sv
Energy rangebull 0015 divide 10 MeV
Overall dimensions weightbull Oslash 60times250 mm 085 kg
GAMMA AND BETA BDKS-96SDetector bull Double GM counters
Measurement rangebull Gamma dose rate H(10) 01 μSvh divide 1 mSvhbull Gamma dose H(10) 01 μSv divide 10 Svbull Beta 10 divide 3104 min-1cm-2
Energy rangebull Gamma 005 divide 3 MeVbull Beta 012 divide 3 MeV
Overall dimensions weightbull Oslash 80times80 mm 035 kgbull Telescopic pole length 07 m
GAMMA BDMG-96Detector bull GM counters
Measurement rangebull Dose rate H(10) 01 μSvh divide 10 Svhbull Dose H(10) 01 μSv divide 10 Sv
Energy range bull 005 divide 3 MeV
Overall dimensions weightbull 40times250 mm 05 kgbull Telescopic pole length 07 m 4 m (by request)
EXTERNAL PROBES GAMMA
BDKS-96B
BDMG-96
BDKS-96S
SPC ldquoDozardquoRadiation monitoring equipment
58 59
GAMMA-SEARCH BDVG-96Detector bull Scintillator NaI(Tl) Oslash 63times63 mm
Measurement rangebull Flux density measurement range 4 divide 2000 s-1cm-2
bull Dose rate H(10) for Cs-137 01 divide 30 μSvhbull Sensitivity for Cs-137 3000 (pulsess-1)( μSvh-1)
Overall dimensions weightbull Oslash 88times400 mm 20 kgbull Modular pole length 16 m
GAMMA-SEARCH BDPG-96Detector bull Scintillator NaI(Tl) Oslash 25times40 mm
Measurement rangebull Flux density measurement range 10 divide 8000 s-1cm-2
bull Dose rate H(10) for Cs-137 01 divide 100 μSvhbull Sensitivity for Cs-137 500 (pulsess-1)( μSvh-1)
Overall dimensions weightbull 50times190times480 mm 10 kgbull Telescopic pole length 07 m
GAMMA-SEARCH BDPG-96MDetector bull Scintillator NaI(Tl) Oslash 18times30 mm
Measurement rangebull Flux density measurement range 10 divide 24000 s-1cm-2
bull Dose rate H(10) for Cs-137 01 divide 300 μSvhbull Sensitivity for Cs-137 200 (pulsess-1)( μSvh-1)
Overall dimensions weightbull Oslash 35times320 mm 05 kgbull Telescopic pole length 07 or 38 m
EXTERNAL PROBES GAMMA
BDVG-96
BDPG-96M
BDPG-96
EXTERNAL PROBESGAMMA BDKG-96 STAINLESS STEEL CASING FOR GEOLOGIC APPLICATIONS WELL LOGGINGDetector bull Scintillator NaI(Tl) Oslash 18times30 mm
Measurement rangebull Flux density measurement range 10 divide 105 s-1cm-2
bull Dose rate H(10) for Cs-137 5 divide 2104 μRhbull Sensitivity for Cs-137 200 (pulsess-1)( μSvh-1)
Overall dimensions weightbull Oslash 38times535 mm 36 kgbull Cable length 10 divide 1000 m
NEUTRON BDMN-96Detector bull Scintillator with ZnS(Ag)
Measurement rangebull Dose rate H(10) 01 μSvh divide 01 Svhbull Dose H(10) 01 μSv divide 10 Sv
Energy range bull 0025 eV divide 10 MeV
Overall dimensions weightbull Detector Oslash 54times200 mm 08 kgbull Moderator Oslash 245 mm 73 kg
NEUTRON-SEARCH BDKN-96Detector bull He-3 counter in polyethilene moderator
Measurement rangebull Dose rate H(10) for Pu-Be 01 μSvh divide 01 Svhbull Dose H(10) for Pu-Be 01 μSv divide 10 Sv
Energy range bull 0025 eV divide 14 MeV
Overall dimensions weightbull 295times142times100 mm 225 kg
BDKG-96M
BDMN-96
BDKN-96
SPC ldquoDozardquoRadiation monitoring equipment
60 61
bull No gas supply neededbull Clothing control detachable right hand detector bull Alpha detector optional connection bull Numeric and color (red green) indication of
control resultsbull LED sensor of hand-foot positioning for start of
measurementbull Automatic compensation of gamma background
and contamination of detectorbull Audible alarm signals of the excess of preset
thresholdsbull Measurement value indication min-1cm-2 or
Bqсm2
Reference standards Nuclear IEC 61098
RZB-05D HAND-FOOT-CLOTHING MONITOR
Physical characteristicsDetectors bull Gamma beta - GM countersbull Alpha - scintillatior ZnS(Ag)
Detecting nuclidesbull Alpha Pu-239 U-234 U-238bull Beta Sr-90+Y-90 F-18 Cs-137 Co-60 Tс-99 O-15
N-13 Sr-89 C-11 I-131 Na-22 Ru-106+Rh-106 Tl-204
bull Gamma Tc-99m I-123
Efficiencybull Alpha
Pu-239 40 U-234 25U-238 15
bull Beta Sr-90 +Y-90 40
Measurement range bull Alpha 1 divide 103 min-1cm-2 bull Beta 10 divide 103 min-1cm-2
bull Gamma 5103 divide 5106 min-1cm-2
Energy range bull Alpha 30 divide 80 MeV bull Beta 008 divide 35 MeV bull Gamma 005 divide 30 MeV
Operation temperature range bull Minus 10 divide +50 ordmС
Electrical characteristicsbull Power supply 220 V 50 Hz
Mechanical characteristicsOverall dimensions weight bull 740times750times1180 mm 45 kg
Versionsbull Withwithout alpha detectorbull Indication (min-1cm-2 ) or (Bqсm2)bull Detectors overall dimensions smbull Hand 178 х 235bull Foot 185 х 436
Whole body contamination monitor RZBA-04-04Mbull No gas supply neededbull Compensation for background gamma radiation
and contamination of detector unitsbull Individual threshold setting for each measure-
ment channelbull Visible and audible alarms ldquoCONTAMINATIONrdquo and
ldquoCLEANrdquo bull Indication of contaminated body parts on the
panel with image of the bodybull Optional remote alpha-detector
Physical characteristicsDetectors bull Beta - GM counters scintillatorsbull Alpha - scintillatior ZnS(Ag)
Measurement range bull Beta 5 divide 15000 min-1cm-2
bull Alpha 01 divide 10000 min-1cm-2
Energy range bull Beta 015 divide 25 MeV bull Alpha 40 divide 56 MeV
Operation temperature range bull +5 divide +50 ordmС
Electrical characteristicsPower supply bull 220 V 50 Hz
Interfaces bull RS-232bull RS-485
Mechanical characteristicsOverall dimensions weight bull 2650times940times930 mm 310 kg
Versionsbull Withwithout alpha detectorbull Indication (min-1cm-2 ) or (Bqсm2)
Reference standards Nuclear IEC 61098
RZBA-04-04MWHOLE BODY CONTAMINATION MONITOR
SPC ldquoDozardquoRadiation monitoring equipment
62 63
RZA-05DALPHA HAND-MONITOR
bull No gas supply needed bull Numeric and color (red green) indication of
control resultsbull LED sensor of hand- positioning for start of
measurementbull Audible alarm signals of the excess of preset
thresholdsbull Measurement value indication min-1cm-2 or
Bqсm2
Physical characteristicsDetectors alpha - scintillatior ZnS(Ag)
Efficiencybull Pu-239 20 bull U-234 14bull U-238 8
Measurement range bull 05 divide 105 min-1cm-2
Energy range bull 41 divide 90 MeV
Operation temperature range bull minus 10 divide +50 ordmС
Electrical characteristicsPower supply bull 220 V 50 Hz
Mechanical characteristicsOverall dimensions weight no more bull 740times1400times1450 mm 70 kg
Reference standards Nuclear IEC 61098
bull Simultaneous measurement of alphabeta activi-ties in the sample
bull Active shielding anti-coincidence background subtraction using GM counters
bull Lead shielding 30 mm
UMF-2000 LOW LEVEL ALPHA- BETA- COUNTER
Physical characteristicsDetectors bull Silicon specrometric detector 500 or 1000 mm2
Measurement range bull Alpha 001 divide 1000 Bq bull Beta 01 divide 3000 Bq
Energy range bull Alpha 35 divide 80 MeV bull Beta 005 divide 35 MeV
Electrical characteristicsPower supply bull 220 V 50 Hz
Interfaces bull RS-232bull USB
Mechanical characteristicsOverall dimensions weight bull 337times286times190 mm 22 kg
Versionsbull Detector area 500 mm2
bull Detector area 1000 mm2
UMF-2000 Detector area 1000 mm2
UMF-2000 Detector area 500 mm2
SpectraDec software for alpha-spectrometric measurements
SPC ldquoDozardquoRadiation monitoring equipment
64 65
DRK DOSE AREA PRODUCT METER
DRK-1bull Diagnostic reference level (DRL) of patients
determinationbull Suitable for all basic types of x-ray machines
Physical characteristicsDetector bull Plane-parallel ionization chamber
Measurement range bull 1 divide 104 cGycm2
Electrical characteristicsPower supply bull 220 V 50 Hz
DRK-1M-CTbull Measuring of dose length product
Physical characteristicsDetector bull Pencil Ionization Chamber
Measurement rangebull 05 divide 109 microGym
DRK-1Mbull Measuring of air kerma on sectional area of the
X-ray beam productbull Measuring of air kerma rate on area productbull Measuring of air kerma ratebull Measuring of air kerma
Physical characteristicsDetector bull Plane-parallel ionization chamber
Measurement rangebull 01 divide 109 microGym2
bull 06 divide 6104 microGym2cbull 30 divide 9105 microGycbull 30 divide 9991011 microGyReference standard IEC 60580 2003
bull Measurement of strontium-90 in the foodstuffs agricultural products etc
bull Measurement of gross beta activity in samplebull Self tests using built-in LED
ldquoPROGRESS-BETArdquo SCINTILLATION BETA SPECTROMETER
Physical characteristicsDetector bull Plastic scintillator Oslash70x10 mm
Sample bull Plate Oslash70 mmbull Weight up to 15 g
Energy range bull 02 divide 30 MeV
Minimum detectable activity of Sr-90 in a 10 g sample on a standard planchet Bqsamplebull In case of absence of K-40 in the sample 01 Bqbull In case the activity of K-40 till 5 Bqg 05 Bq
Electrical characteristics Interface bull USB
Mechanical characteristicsWeight bull No more 50 kg
Complete setBasic complete setbull Detector unit with plastic scintillator integrated
power supply amplifier ADC bull Lead shielding bull ldquoProgressrdquo software bull Сheck source for energetic calibration (Sr-90-Y-90) bull Planchet Oslash 70 mm (5 items) bull Sample dencification device bull Procedure manual for measurement of radio-
nuclidesrsquo activity using the scintillation beta spec-trometer ldquoProgressrdquo
Optional equipment and servicebull Personal computer and printer bull Calibrations for radionuclides not included in the
main library of radionuclides
Progress-Beta
Reference standards IEC 61562
SPC ldquoDozardquoRadiation monitoring equipment
66 67
bull Measurement of gamma activity in foodstuffs soil samples and others environmental objects
bull Identification of radionuclides in the sample bull Automatic correction for sample density bull Self-tests using built-in LED
ldquoPROGRESS-GAMMArdquoSCINTILLATION GAMMA SPECTROMETER
Physical characteristicsDetector bull NaI (Tl) Oslash63times63 mm
Validated measurement geometries bull Marinelli beakers (1 liter) Petri dishes (Oslash90 mm)
etc
Energy range bull 02 divide 30 MeV
Minimum detectable activity Bqsamplebull Cs-137 3 Bqbull Th-232 7 Bqbull Ra-226 8 Bq bull К-40 40 Bq
Electrical characteristics Interface bull USB
Mechanical characteristicsWeight bull No more 120 kg
Complete setBasic complete setbull Scintillation detector unit with NaI (Tl) detector
with integrated power supply amplifier and ADC bull Lead shielding 50 mm bull ldquoProgressrdquo software bull Сheck source for energy calibration (Cs-137 +
K-40)bull Marinelli beakers - 1 liter (5 items) bull Petri dishes Oslash 90 mm (5 items) bull Procedure manual for measurement of activity
of radionuclides using the scintillation gamma spectrometer ldquoProgressrdquo
Optional equipment and servicebull Kit for radon measurements including calibration
of ldquoIC-63rdquo geometry for counting the charcoal samples
bull Personal computer and printer bull Calibrations for user defined geometries bull Calibrations for radionuclides not included in the
main library of radionuclides
Progress-Gamma
Reference standards IEC 61563
ldquoPROGRESS-G(P)rdquoPORTABLE SCINTILLATION GAMMA SPECTROMETERbull Field measurements of gamma activity in environ-
mental objects without sampling (4π geometry)bull Laboratory measurement of gamma activity in
foodstuffs soil samples and others environmental objects
bull Identification of radionuclides in the sample bull Automatic correction for sample densitybull Tests using built-in LED
Physical charachteristicsDetector bull NaI (Tl) Oslash45times50 mmbull Lead shielding 20 mm
Validated measurement geometries bull Marinelli beakers (05 liter) Petri dishes (Oslash90 mm)
etc
Energy range bull 02 divide 30 MeV
Minimum detectable activity in 05-litre Marinelli beaker bull Cs-13710 Bqkgbull К-40100 Bqkgbull Ra-22618 Bqkg bull Th-23216 Bqkg
Minimum detectable activity in 30 min (4π geometry) bull Cs-137 2 Bqkgbull К-40 30 Bqkgbull Ra-226 4 Bqkg bull Th-232 3 Bqkg
Electrical characteristicsPower supply bull Rechargeable batterybull 220 V 50 Hz
Interface bull USB RS-232
Weight bull No more than 60 kg
Complete setBasic complete setbull Scinttillation detector unit with NaI(Tl) bull ldquoProgressrdquo softwarebull Сontrol unit ldquoSputnikrdquo for aquisition and analisys
of spectra with built-in memory for spectral databull Casebull Lead shielding (2 cm) for laboratory usebull 05-litre Marinelli beakers ndash 5 itemsbull Na-22 check sourcebull Power adapter BPS-01bull Operation manualbull Procedure manual for measurement of activity
of radionuclides using the scintillation gamma spectrometer ldquoProgressrdquo
Optional equipment and servicebull Kit for radon measurements with charcoalbull Built-in dose rate meterbull Additional memory (RAM) for storage of 64
spectrabull Additional power adapterbull Notebook and printer
Progress-Gamma
Reference standards IEC 61563
SPC ldquoDozardquoRadiation monitoring equipment
68 69
Physical characteristicsDetectorbull Scintillation detector ZnS (Oslash 60 mm)
Samplebull Thin sample - diameter up to 70 mm bull Preparation technique - electro-depositionbull Thick sample - diameter 70 mm weight
200300 mg bull Preparation technique - application of powders
(prepared by radiochemical concentration by water evaporation or by pounding of mineral samples) onto a planchet with the help of spirit
Energy rangebull 15 divide 8 MeV
Minimum detectable activitybull Thin samples no more than 910-3 Bqsamplebull Thick samples no more than 180 Bqkg
Mechanical characteristicsOverall dimensions weightbull 195times120times210 mm 34 kg
Complete setBasic complete setbull Alpha radiometer ldquoProgress-ARrdquobull Check source (uranium isotopes)
Set of accessoriesbull Procedure manual for measurements of radi-
oactivity using scintillation alpha radiometer ldquoProgress-ARrdquo
bull ldquoProgressrdquo software
ldquoProgress-ARrdquo
bull Measurement of gross activity of alpha emitting radionuclides in thin samples
bull Measurement of gross activity of alpha emitting radionuclides in thick samples
bull Measurement of activity deposited on aerosol filters
ldquoPROGRESS-ARrdquoALPHA RADIOMETER
Several fixed positions of the detector enable to perform measurements in various geometries and to estimate the content ofbull Cs-137 in the whole bodybull I-131 in thyroidbull Co-60 Cs-137 Mn-54 Cr-51 in lungsbull Database for storage of measurement data and
resultsbull Uncertainty calculations based on measurement
databull Self tests using built-in LED
ldquoPROGRESSrdquo WHOLE BODY COUNTER
Physical characteristicsDetectorbull scintillation detector NaI (Tl) Oslash63times63 mm
Energy rangebull 02 divide 28 MeV
Minimum detectable activitybull By Cs-137 in the whole body - 1200 Bqbull By I-131 in thyroid - 100 Bqbull By Co-60 Cs-137 Mn-54 Cr-51 in lungs - 200 Bq
Mechanical characteristicsWeight bull No more than 120 kg
Complete setBasic complete setbull Collimator with rotator and holderbull Detector with incorporated ADCbull Patient chair and table for collimatorbull Check source Na-22bull Procedure manual for lifetime measurement of
gamma-emitting radionuclidesrsquo activity in human body using the gamma-spectrometer of human radiation ldquoProgressrdquo
bull laquoProgressraquo software
Optional equipment and servicebull Program of internal radiation committed internal
radiation effective dose calculation by the stand-ard model
bull Background phantombull Personal computer and printer
Collimator with rotator and holder
SPC ldquoDozardquoRadiation monitoring equipment
70 71
bull Categorization of wastes for the purpose of fur-ther processing including wastes with unknown radionuclide composition
bull Measurements during the incoming waste inspec-tion (accepting for storage disposal)
bull Certification of unconditioned and conditioned wastes in closed containers without opening them (at nuclear plants or at facilities providing collection storage transportation conditioning processing temporal storage and final disposal of radioactive waste)
bull Activity measurement of extended objects in situ without opening the equipment
bull Activity measurement of extended objects after opening (for example assessment of tubes used for oil transportation)
MKG-01D ldquoSADOVNIKrdquoSPECTROMETRY SYSTEM
Physical charachteristicsDetectorbull Detector unit GEM (GMX) with HPGe detector and
multi-positioning cryostat CFG-PMOD4-7 with 7 litre Dewar
bull Dose rate probe BDMG-200
Energy range bull With GEM detector 004 divide 30 MeVbull With GMX detector 0005 divide 15 MeVbull Dose rate probe BDMG-200 ndash 005 divide 30 MeV
Measurement rangebull 110-7 divide 10 Svhbull Relative efficiency of detection (in photopeak) at
13325 MeV (Co-60) 10 divide 150
Electrical characteristicsPower supplybull 220 V 50 Hz
Interfacebull USB
Complete setBasic complete setbull Spectrometric detector unit GEM (GMX) with
HPGe detector and multi-positioning cryostat with 7 litre Dewar
bull Portable digital multichannel analyzer DigiDARTbull Dose rate probe BDMG-200bull Autonomous power supply unit with built-in
batterybull Industrial computer keyboardbull Laser range-finderbull Thermographic printerbull Web-camerabull Device equipped with stepper motor for position-
ing of the spectrometric detectorbull Calibration device with reference sources
(Am-241 Co-60 Ba-133 Eu-152) for energy calibration
bull Removable collimators with end capbull Measurement proceduresbull ldquoClasterrdquo software
bull Measurement of gross alpha activity of alpha-emitting radionuclides
bull Measurement of alpha-emitting radionuclides activity in thin-layer samples meeting alpha-spectrometry requirements
Physical characteristicsDetectorbull Silicon ion-implanted 450 mm2
bull Easy to decontaminate thin windowbull dead layer less than 015 μmbull Background count rate in the range 3 divide 9 MeVbull No more than 09 h-1cm-2 for 450 mm2 detector
Energy rangebull 2 divide 9 MeVbull Lower limit of measurement range (minimum
detectable activity) 01 Bqbull Background count rate no more than 100 counts
in 24 hours
Electrical characteristics Power supplybull 220 V 50 Hz
Interfacebull USB
Complete setBasic complete setbull Detector unit with vacuum measuring chamber
and vacuum control systembull Low noise vacuum pump (type 2FY-05B or
equivalent)bull Check sourcebull ldquoProgressrdquo softwarebull Vacuum tube
MKS-01A ldquoMULTIRAD-ASrdquoALPHA SPECTROMETER
SPC ldquoDozardquoRadiation monitoring equipment
72 73
UCRV-2AIRFLOW MONITOR
bull Monitor of the air flow through filter of centralized multichannel sampling system
bull Radiation monitoring system (RMS) integration for internal exposures determination
bull Volume and flow rate measurements of the air that have passed through a analytical filter
bull Bar-code for filter identificationbull Operation as either standalone unit or as a part of
the RMS
Physical characteristicsMeasurement range of air volume bull 001 divide 9999 m3
Operation temperature range bull minus 20 divide +50 ordmС
Electrical characteristicsPower supply bull 220 V 50 Hz
Interface bull RS-485
PVP-06PORTABLE AIR SAMPLER
Air Sampler PVP-06 is indispensable for monitoring the radiation situation where the concentration of radioactive aerosols in the air does not require a sta-tionary sampling equipment Sampling head PVP-06 provides easy change of filters and cartridges
Purposebull To monitor the concentration of radioactive aero-
sols in the air sites
Controlled aerosolsbull Alpha- and beta-active aerosolsbull Daughter products of decay of radon and thoronbull Iodine isotopes
Physical characteristicsTypes of filtersbull Aerosol AFA-RSP-20bull Iodine AFA SI-20
Flow rate bull 33∙10-4 ndash 233∙10-4 m3s (20 divide 140 l min)
Electrical characteristicsPower supply bull 220 V50 Hzbull The vehicle power supply 108 divide 145 Vbull Internal battery
Minimal working time on internal battery to recharge bull 8 hours
Power consumption (at a flow rate of 100 lmin) bull 40 VA
Environment characteristicsOperating temperature bull minus 10 divide +40 deg C
Maximum humidity bull 90
Pressure bull 860 to 1060 hPA
Noise generated by the pump bull lt 55 dBA at 1 m
Mechanical characteristicsDimensions weight bull 241 times 108 times 160 mm 28 kg
Case material bull Plastic
Complete setbull Air sampler PVP-06bull AC power adapterbull Filters AFA-RSP-20 - 100 pcsbull Packaging for filters - 40 pcsbull Casebull Operation manualbull Calibration certificate
Optional equimpient bull Kit for sampling sorption columns of activated
carbon Ř head of sorption columns with protective
covers Ř activated charcoal SKT-3 - 1 pkg (02 L) Ř charocoal samples SC-13 - 8 pcs
bull Car charger bull Tipod bull Shoulder strapbull Calibration stand bull Filters AFA SI-20 - 100 pcs
Consumablesbull Aerosol filters AFA RSP-20bull Iodine filters AFA SI-20
SPC ldquoDozardquoRadiation monitoring equipment
74 75
Calibration of gamma dose and dose rate meters
Calibration ofbull Ambient equivalent dose H(10) meters (Sv Svh)bull Personal equivalent dose Hp(10) meters (Sv Svh)bull Exposure dose X meters (R Rh)bull Two sources in irradiator bull Select source and collimator opening using
tumbler
UPG-P DESKTOP GAMMA BEAM IRRADIATOR
Physical characteristicsRange of reproduced dose rate bull 05 μSvh divide 10 mSvh (50 μRh divide 100 mRh)
Sources activities bull 6times106 6times108 Bq (02 20 mCi) Cs-137
Overall dimensions bull 1250times400times300 mm
Irradiator weight bull Not more than 37 kg
Calibration bench weight bull Not more than 15 kg
Reference standards IEC 60846 IEC 61526
Physical characteristicsDetectorbull Silicon
Measurement range EEC measurement bull Measurement range of radon EEC
10 divide 10bull106 Bqbullm-3
bull Measurement range of thoron EEC 05 divide 10bull104 Bqbullm-3
bull Air flow through the filter 100plusmn05 lmin
Concentration measurementbull Measurement range of radon-222 concentration
in air 10 divide 20bull106 cpsbull Measurement range of 216Po(ThA)
1bull10-3 divide 1bull102 cpsbull Air sampler flow rate
10plusmn02 lminbull Measurement range of radon-222 concentration
in water samples 6 divide 800 Bqbullkg-1
bull Measurement range of radon-222 flux from soil surface 20 divide 103 mBqsbullm2
bull Measurement range of radon-222 concentration with preliminary sampling of air using air sam-plers 20 divide 107 Bqbullm-3
bull Measurement range of radon-222 concentration in samples of soil air 103 divide 106 Bqbullm-3
Operation temperature range bull 1 divide 35 ordmC
Electrical characteristicsPower supply bull 80 VA
Mechanical characteristicsOverall dimensions weight bull 220times200times165 mm 36 kg
ldquoALPHARAD PLUSrdquoRADON THORON amp THEIR PROGENY MONITORbull Measurement of radon and thoron concentration
and effective equivalent concentration (EEC)bull In the airbull In the indoor air of residential public and industri-
al buildings and structuresbull Measurement of radon in drinking water sourcesbull Measurements of radon flux from the soil surface
at land plots allocated for construction of houses public buildings and industrial facilities
bull Measurements of radon concentration in soil air
Reference standards IEC 61577
SPC ldquoDozardquoRadiation monitoring equipment
76 77
UKPN-2M-D NEUTRON BEAM IRRADIATOR
Reference standards IEC 61005 61322
Calibration of neutron dose and dose rate meters
Calibration ofbull Ambient equivalent dose H(10) meters (Sv Svh)bull Personal equivalent dose Hp(10) meters (Sv Svh)bull Flux density of neutrons (cm-2∙s-1)bull Transfer container for temporary storage of
sources bull Red light signal of source working position
Physical carachteristicsRange of reproduced dose ratebull 20 divide 800 μSvh
Range of reproduced flux densitiesbull 10 divide 400 cm-2∙s-1
Type of a source in use bull Pu-Be
Activity of a source in usebull 24х1011 Bq (with density of 107 s-1)
Overall dimensions weight no morebull 3000x750x2000 mm 300 kg
Required room dimensionsbull not less than 7x3x3 m
Electrical characteristicsPower supply bull 220 V 50 Hz
Calibration of gamma dose and dose rate meters
Calibration ofbull Ambient equivalent dose H(10) meters (Sv Svh)bull Personal equivalent dose Hp(10) meters (Sv Svh)bull Exposure dose X meters (R Rh)bull Four sources in irradiator bull Select source and move to working position
return to storage position using special rodbull Transfer container for temporary storage of
sources bull Red light signal of source working position
UPGD-2M-DGAMMA BEAM IRRADIATOR
Physical characteristicsRange of reproduced dose rate bull 05 μSvh divide 50 mSvh (50 μRh divide 5 Rh)
Maximum activity of source bull 2times1011 Bq (50 Ci) Cs-137
Overall dimensionsbull Irradiator 800times500times500 mmbull Guide rails length 30 mbull Height 16 mbull Weight not more than 700 kgbull Required room dimensions not less than 7x3x3 m
Electrical characteristicsPower supply bull 220 V 50 Hz
UPGD-2M-D
Reference standards IEC 60846 IEC 61526 IEC 61066
SPC ldquoDozardquo
78 79
Contents
MEASURING UNITS
DBG-S11D wide range gamma area monitor 40
UDKS-100 gamma and X-ray area monitor 41
UDMN-100 neutron area monitor 41
ALARM UNITS
BAS-2 ldquoMICROrdquo external visual alarm 42
BZS-2 ldquoMicrordquo external audible alarm 42
Illuminated warning signs 43
ldquoImpulsrdquo external display unit 43
UIM-3D area monitor count rate meter 44
DKG-05D personal gamma dosimeter 46
DVS-02D gamma-neutron personal electronic dosimeter 47
DVGI-8D new pen-type personal ionization chamber dosimeters 48
DKG-02U ldquoARBITERrdquo wide range gamma-dosimeter 49
DKG-07D ldquoDROZDrdquo gamma-dosimeter 50
MKS-15D ldquoSNEGIRrdquo multi ndash purpose radiation survey meter 51
SRPS-05D gamma monitor 52
DOZA-TLD multipurpose TLD system 53
DKS-96 universal radiation survey meter 54
EXTERNAL PROBES ALPHA
Alpha BDZA-96 55
Alpha BDZA-96B 55
Alpha BDZA-96M 55
Alpha BDZA-96S 55
Alpha BDZA-96T 55
EXTERNAL PROBES BETA
Beta BDZB-96 56
Beta BDZB-99 56
Beta BDZB-96B 56
Beta BDZB-96S 56
EXTERNAL PROBES GAMMA
Gamma BDKS-96B 57
Gamma and beta BDKS-96S 57
Gamma BDMG-96 57
EXTERNAL PROBES GAMMA
Gamma-search BDVG-96 58
Gamma-search BDPG-96 58
ContentsRadiation monitoring systemldquoPELIKANrdquo Radiation monitoring system (RMS) 6
BDMG-101 high range gamma area monitor 10
DBG-S11D wide range gamma area monitor 11
BDRG-52 high range gamma area monitor for accident and post-accident conditions 12
UDGP-01 Liquid technological environments monitor 13
UDMN-100 neutron area monitor 14
UDKG-100 Wel Liquid gamma monitor 14
BOP-1M data processing and transmission unit 15
UDA-1AB particulate monitor 16
UDG-1B noble gas monitor 17
UDG-03D noble gas monitor 18
UDI-1B iodine monitor 19
UDGB-01 noble gasesH-3C-14 monitor 20
UDGP-01 steam generator leakage monitor 21
UPPVM air flow parameters monitor 22
ldquoIMPULSrdquo external display unit 23
BI-2 remote display amp alarm unit 24
BASBAS-1s external alarm 25
SKGAV stack monitor 26
RMS software 28
RMS workstation ndash operator console 29
Configurator software 29
RM RACK radiation monitoring rack 30
SRKS-01D criticality accident alarm system 32
ldquoATLANT-Mrdquo environmental radiation monitoring system 34
ldquoBREEZErdquo high-volume air sampler 35
ldquoGAMMA-SENSORrdquo gamma-survey system 36
Radiation monitoring equipmentAREA MONITOR ldquoFREGATrdquo 38
BPI-1D local display unit 39
80
Gamma-search BDPG-96M 58
Gamma BDKG-96 stainless steel casing for geologic applications well logging 59
EXTERNAL PROBES NEUTRON
Neutron BDMN-96 59
Neutron-search BDKN-96 59
RZB-05D Hand-foot-clothing monitor 60
RZBA-04-04M whole body contamination monitor 61
RZA-05D alpha hand-monitor 62
UMF-2000 low level alpha- beta- counter 63
DRK dose area product meter 64
ldquoPROGRESS-BETArdquo scintillation beta spectrometer 65
ldquoPROGRESS-GAMMArdquo scintillation gamma spectrometer 66
ldquoPROGRESS-G(P)rdquo portable scintillation gamma spectrometer 67
ldquoPROGRESS-ARrdquo alpha radiometer 68
ldquoPROGRESSrdquo whole body counter 69
MKG-01D ldquoSADOVNIKrdquo spectrometry system 70
MKS-01A ldquoMULTIRAD-ASrdquo alpha spectrometer 71
UCRV-2 airflow monitor 72
PVP-06 portable air sampler 73
ldquoALPHARAD PLUSrdquo radon thoron amp their progeny monitor 74
UPG-P desktop gamma beam irradiator 75
UPGD-2M-D gamma beam irradiator 76
UKPN-2M-D neutron beam irradiator 77
Radiation monitoring system SPC ldquoDozardquo
14 15
BOP-1M DATA PROCESSING AND TRANSMISSION UNIT
bull Processing of data incoming from detecting blocks UDMN-100 DBG-S11D UDKG-100 BDMG-101 BDRG-52
bull Data transmission to the network bull Data transmission to the mobile computer bull Storage of thresholds values and parameters of
detecting blocksbull Power supply and diagnostics of detecting blocks bull Generation of the alarm signals of the excess of
preset thresholdsbull Data backup in the non-volatile memory
Physical characteristicsbull Quantity of joined detecting blocks and alarm
units ndash up to 20bull Temperature range minus 40 divide +50 ordmC
Electrical characteristicsbull Power supply 85 divide 260 V 47 divide 440 Hzbull Interfaces RS-232 RS-485 Ethernet bull programmable relay output (SPDT relay)
Mechanical characteristicsbull Protection index IP 65 bull Paint decontaminable
Overall dimensions weightbull 298times220times114 mm 5 kg
Reference standards EMC IEC 61010 IEC 61000-6-2 Seismic IEC 60980
Continuous automatic monitoring of the neutron-radiations ambient dose equivalent ratebull Spherical polyethylene moderator Oslash 239 mm
UDMN-100 NEUTRON AREA MONITOR
Physical characteristicsbull detector ndash scintillator ZnS(Ag) Li-6
Measurement range bull 01 μSvh divide 01 Svh
Energy range bull 0025 eV divide 100 MeV
Temperature range bull minus 45 divide +50 ordmC
Electrical characteristicsbull Interfaces RS-485
Reference standards Nuclear IEC 61005 IEC 61322 EMC IEC 61010 IEC 61000-6-2 Seismic IEC 60980
UDKG-100WEL LIQUID GAMMA MONITOR
Mechanical characteristicsbull Protection index IP 65bull Paint decontaminable
Overall dimensions weight bull 428times258times347 mm 115 kg
Continuous automatic monitoring of the gamma radiation flux Operation in the rocks ore liquid media and sludge
Physical characteristics bull detector ndash NaI (Tl) Oslash 18x30 mm
Measurement range bull 40 divide 8104 s-1cm-2
Energy range bull 01divide 30 MeV
Temperature rangebull minus 40 divide +50 degC
Electrical characteristics bull Interfaces RS-485
Mechanical characteristics bull Protection index
Ř BDKG-100 IP 68 Ř Interface block BS-16 IP 65
bull Paint stainless steel bull Overall dimensions weight
Ř Detector unit BDKG-100 Oslash 38times530 mm 3 kg Ř Interface block BS-16 176times80times64 07 kg
Radiation monitoring system SPC ldquoDozardquo
16 17
UDG-1B NOBLE GAS MONITOR
Continuous automatic monitoring of the beta-emit-ting radioactive gases concentration in the working air and in the air in ventilation ducts and stacksbull Gamma background compensation bull Audible and visual alarm signals of the excess of
preset thresholds bull Periodic calibration by means of standard beta-
source
Physical characteristicsbull Silicon detectors (2 pcs for measurement and for
background compensation)bull Air flow rate 10 divide 100 lminbull Operation temperature range minus 10 divide +50 ordmС
Measurement range bull 104 divide 6109 Bqm3
Energy range bull 008 divide 30 MeV
Electrical characteristicsbull Power supply 85 divide 260 V 47 divide 440 Hzbull Interfaces RS-232 2timesRS-485 Ethernetbull programmable relay output (SPDT relay)bull Analog output 4-20 mA (optional)
Mechanical characteristicsbull Protection index IP 65bull Paint decontaminable
Overall dimensions weight bull Stationary version 395times240times304 mm 295 kgbull Mobile version with pump unit BN-1
395times468times950 mm 543 kg
Alarmbull Sound alarm 80 divide 100 dBA at distance 1 mbull Visual alarm green yellow red
Mobile version with pump unit BN-1
Stationary version
Reference standards Nuclear IEC 60761 IEC 62302 EMC IEC 61010 IEC 61000-6-2 Seismic IEC 60980
bull Connection of the external alarm unit ldquoBASrdquo type
Versionsbull Stationary versionbull Stationary version with pump unit BN-1bull Mobile version with pump unit BN-1
UDA-1AB PARTICULATE MONITOR
Stationary version
Continuous automatic monitoring of the alpha- and beta- radioactive aerosol concentration in the work-ing air and in the air in ventilation ducts and stacksbull Radon toron progenies and gamma background
compensation bull On line alpha spectrometrybull Audible and visual alarm signals of the excess of
preset thresholds bull Control of electromagnetic valves when operating
with the external air sampling linebull Control of pump unit bull Periodic calibration by means of standard beta-
and alpha-sources
Physical characteristicsbull Silicon specrometric detectors (2 pcs for measure-
ment and for background compensation)bull Filter tape types LFAS FSLWbull Tape consumption (when continuous operation)
10 m50 daysbull Air flow rate 10 divide 100 lmin bull Operation temperature range minus 10 divide +50 ordmС
Measurement range bull Alpha 10-2 divide 2105 Bqm3 bull Beta 10-1 divide 106 Bqm3
Energy range bull Alpha 30 divide 90 MeV bull Beta 005 divide 30 MeV
Electrical characteristicsbull Power supply 85 divide 260 V 47 divide 440 Hzbull Interfaces RS-232 2timesRS-485 Ethernet bull Programmable relay output (SPDT relay)bull Analog output 4-20 mA (optional)
Mechanical characteristicsbull Protection index IP 65bull Paint decontaminable
Overall dimensions weight bull Stationary version 389times260times304 mm 156 kg bull Mobile version with pump unit BN-1
389times468times950 mm 384 kg
Alarmbull Sound alarm 80 divide 100 dBA at distance 1 mbull Visual alarm green yellow redbull Connection of the external alarm unit ldquoBASrdquo type
Versionsbull Stationary versionbull Stationary version with pump unit BN-1bull Mobile version with pump unit BN-1
Reference standards Nuclear IEC 60761 IEC 61172 EMC IEC 61010 IEC 61000-6-2 Seismic IEC 60980
Mobile version with pump unit BN-1
Radiation monitoring system SPC ldquoDozardquo
18 19
Physical characteristicsbull Scintillation detectors CsI(Tl) (2 pcs for measure-
ment and for background compensation)bull Cartridge activated charcoal
Measurement range bull 37 divide 37106 Bqm3
Energy range bull 006 divide 30 MeVbull Air flow rate 20 divide 40 lminbull Operation temperature range minus 10 divide +50 ordmС
Electrical characteristicsbull Power supply 85 divide 260 V 47 divide 440 Hzbull Interfaces RS-232 2timesRS-485 Ethernetbull Programmable relay output (SPDT relay)bull Analog output 4-20 mA (optional)
Mechanical characteristicsbull Protection index IP 65bull Paint decontaminable
Overall dimensions weight bull Stationary version 448times323times479 mm 35 kgbull Mobile version with pump unit BN-1
448times468times950 mm 578 kg
Reference standards Nuclear IEC 60761 IEC 61171 EMC IEC 61010 IEC 61000-6-2 Seismic IEC 60980
Alarmbull Sound alarm 80 divide 100 dBA at distance 1 mbull Visual alarm green yellow redbull Connection of the external alarm unit of ldquoBASrdquo
type
Versionsbull Stationary versionbull Stationary version with pump unit BN-1bull Mobile version with pump unit BN-1
Сontinuous automatic monitoring radioiodine concentration in the air at working places and in ventilation ducts and stacksbull Measurement of volumetric activity of radionu-
clides I-131 I-132 I-133 I-135 in the airbull On line gamma spectrometrybull Gamma background compensation bull Performance self-test by means of Am-241 check
source implanted into the detectorbull Audible and visual alarm signals of the excess of
preset thresholdsbull Periodic calibration by means of standard source
UDI-1B IODINE MONITOR
Physical characteristicsbull Silicon detector 2 pcs (for measurement and for
background rejection)bull Air flow rate 10 divide 100 lminbull Operation temperature range minus 10 divide +50 ordmС
Measurement range bull 104 divide 11010 Bqm3
Energy rangebull 006 divide 30 MeV
Electrical characteristicsbull Power supply 120 Vbull Interface RS-485
Mechanical characteristicsbull Protection index IP 65bull Paint decontaminable
Overall dimensions weight bull 474х246х243 mm 295 kg
UDG-03D NOBLE GAS MONITOR
Measurement of volumetric activity of beta-emitting radioactive gases (argon krypton xenon) adapted to the measurement of the rapidly changing volume activity in various technological processesbull Gamma background compensationbull Periodic calibration by means of standard beta-
source
Reference standards Nuclear IEC 60761 IEC 62302 EMC IEC 61010 IEC 61000-6-2 Seismic IEC 60980
Radiation monitoring system SPC ldquoDozardquo
20 21
Continuous automatic monitoring of steam genera-tor primary to secondary leakagebull On line gamma spectrometrybull N-16 monitoringbull Performance self-test by means of Am-241 check
source implanted into the detectorbull Audible and visual alarm signals of the excess of
preset thresholds
Physical characteristics
UDGP-01 STEAM GENERATOR LEAKAGE MONITOR
bull detector ndash scintillator CsI Oslash 40х100 mm
Measurement range bull High energy gamma-activity (N-16)
15bull103 divide 20bull108 Bqm3
bull General gamma-activity 10bull104 divide 20bull108 Bqm3
Energy range bull General gamma 005 divide 15 MeV bull in integral spectral band of energy
5000 divide 7200 keV bull temperature range minus 10 divide +80 ordmС
BOP-1SP
Electrical characteristicsbull Power supply 85 divide 260 V 47 divide 440 Hzbull Interfaces RS-232 RS-485 Ethernetbull programmable relay output (SPDT relay)
Mechanical characteristicsbull Protection index IP 65bull Paint decontaminable
Overall dimensions weight bull Detector unit Oslash 60x360 mm17 kgbull Data processing and transmission unit BOP-1sp
280x220x114mm 43 kgbull Collimator Oslash 350x455 mm 150 kg
Alarmbull Sound alarm 80 divide 100 dBA at distance 1 mbull Visual alarm green yellow redbull Connection of the external alarm unit of ldquoBASrdquo
type
Reference standards Nuclear IEC 61453 EMC IEC 61010 IEC 61000-6-2 Seismic IEC 60980Reference standards Nuclear IEC 60761 IEC 60710 IEC 60951-2 EMC IEC 61010 IEC 61000-6-2 Seismic IEC 60980
Ionization chambe 10 liters
UDGB-01T1
Physical characteristicsbull Detectors - stainless steel ionization chambersbull Air flow rate 10 divide 100 lminbull Operation temperature range minus 10 divide +50 ordmС
Volumes of ionization chambers bull UDGB-01T UDGB - 01T1 100 litersbull UDGB-01T2 01 liter
Measurement range (Kr-85) bull UDGB-01T UDGB-01T1 10104 divide 50109 Bqm3
bull UDGB-01T2 109 divide 501014 Bqm3
Measurement range (H-3) bull UDGB-01T UDGB-01T1 50104 divide 50109 Bqm3
bull UDGB-01T2 50109 divide 501014 Bqm3
Electrical characteristicsbull Power supply 85 divide 260 V 47 divide 440 Hzbull Interfaces RS-232 2timesRS-485 Ethernetbull Programmable relay output (SPDT relay)bull Analog output 4-20 mA (optional)
Mechanical characteristicsbull Protection index IP 23bull Paint decontaminable
Continuous automatic monitoring of the beta-emitting radioactive gases including tritium and carbon-14 concentration in the air at working places and in ventilation ducts and stacksbull Audible and visual alarm signals of the excess of
preset thresholds bull Monitoring of the noble gase activity in gaseous
effluents and ventilation air for accident and post-accident conditions
Overall dimensions weight bull UDGB-01T 381times343times716 mm 30 kgbull UDGB-01T1 260times320times175 mm 125 kgbull Ionization chamber 100 liters Oslash 250times600 mm
6 kgbull UDGB - 01T2 381times343times716 mm 27 kg
Alarmbull Sound alarm 80 divide 100 dBA at distance 1 mbull Visual alarm green yellow redbull Connection of the external alarm unit ldquoBASrdquo type
Versionsbull UDGB-01T - with built-in ionization chamber
100 litersbull UDGB-01T2 - with built-in ionization chamber
01 literbull UDGB-01T1 - with remote ionization chamber
100 liters
UDGB-01NOBLE GASESH-3C-14 MONITOR
Radiation monitoring system SPC ldquoDozardquo
22 23
Physical characteristicsLength of communication cablebull up to 1200 m
Character height bull ldquoImpuls-910-Rrdquo 100 mmbull ldquoImpuls-915-D4Srdquo 150 mmbull ldquoImpuls-927-D4Srdquo 270 mm
Operating temperature rangebull ldquoImpuls-910-Rrdquo 0 divide +50 ordmCbull ldquoImpuls-915-D4Srdquo ldquo-927-D4Srdquo minus 40 divide +50 ordmC
Electrical characteristicsbull Power supply 220 V 50 Hz
Mechanical characteristicsProtection index bull ldquoImpuls-910-R IP 44bull ldquoImpuls -915-D4Srdquo ldquo-927-D4Srdquo IP 65
Overall dimensions weight bull ldquoImpuls-910-Rrdquo 400times160times60 mm 3 kgbull ldquoImpuls -915-D4Srdquo 815times250times80 mm 5 kgbull ldquoImpuls -927-D4Srdquo 1250times330times80 mm 5 kg
ldquoIMPULSrdquoEXTERNAL DISPLAY UNIT
Display of data received from monitors of RMS
External display unit ldquoImpuls-910-Rrdquo
Reference standards EMC IEC 61010 IEC 61000-6-2 Seismic IEC 60980
Continuous monitoring of the flow rate temperature and humidity of the gas flowbull Definition of air volume flow rate in stacks taking
into account temperature and humidity of the air
UPPVM AIR FLOW PARAMETERS MONITOR
Physical characteristicsMeasurement range bull air flow velocity 1 divide 20 msbull air temperature 0 divide +80 ordmСbull air humidity 10 divide 95
Electrical characteristicsbull Power supply 220 V 50 Hz bull Interfaces RS-232 Ethernet
Mechanical characteristicsProtection index bull BSPP-1st BSPP-1tv BOP-1s IP 65bull PP-st IPTV IP 54bull Paint decontaminable
Overall dimensions weight bull air velocity probe PP-st 60times38times136 mm 015 kgbull Interface block BSPP-1st 125times155times73 mm 07 kgbull air temperature and relative humidity probe
IPTV-056-A 333times100times60 mm 07 kgbull Interface block BSPP-1tv 125times155times73 mm 07 kgbull Data processing and transmission unit BOP-1s
280x233x111 mm 8 kg
Reference standards Nuclear ISO 2889 EMC IEC 61010 IEC 61000-6-2 Seismic IEC 60980
BOP-1S
Radiation monitoring system SPC ldquoDozardquo
24 25
BASBAS-1S EXTERNAL ALARM
Generation of audible and visual signals of the excess of preset thresholds RMS monitorsbull Audible alarm 80 divide 100 dBA at distance 1 mbull Visual alarm green yellow red
Distance from RMS monitorbull BAS up to 20 mbull BAS-1s up to 1200 m
Power supply bull 220 V 50 Hz
Overall dimensions weight bull BAS 145times108times460 mm 18 kg bull BAS-1s 166times109times466 mm 18 kg
Reference standards EMC IEC 61010 IEC 61000-6-2 Seismic IEC 60980
Physical characteristicsLength of communication cablebull up to 1200 m
Displayed page size bull 4 lines of 20 characters
Volume of loaded information bull 10 pages
Change of pagesbull programmed or by pressing a button
Operating temperature rangebull minus 40 divide +50 ordmC
Electrical characteristicsbull Power supply 9 divide 18 VDCbull Interfaces RS-485
Mechanical characteristicsbull Protection index IP 65bull Overall dimensions weight 222times164times73 mm
40 kg
BI-2 REMOTE DISPLAY amp ALARM UNIT
bull Display of data received from monitors of RMSbull Audible and visual alarms on exceeding preset
thresholds of the RMS equipment bull Individual threshold setting for each measure-
ment channelbull Audible alarm 80 divide 100 dB at a distance of 1 m bull Visual alarm red yellow green
Reference standards EMC IEC 61010 IEC 61000-6-2 Seismic IEC 60980
Radiation monitoring system SPC ldquoDozardquo
2726
Electrical characteristicsbull Power supply 220 V 50 Hz bull Interfaces RS-232 RS-485 Ethernetbull programmable relay output (SPDT relay)
Alarmbull Sound alarm 80 divide 100 dBA at distance 1 mbull Visual alarm green yellow redbull Connection of the external alarm unit ldquoBASrdquo type
Related monitors and equipmentsbull UDA-1AB particulate monitorbull UDG-1B noble gas monitorbull UDI-1B iodine monitorbull UPPVM air flow parameters monitorbull Sampling and sample separation rack
Air flow parameters monitor rack
Reference standards Nuclear IEC 60761 IEC 61171 IEC 61172 IEC 62302 ISO 2889 EMC IEC 61010 IEC 61000-6-2 Seismic IEC 60980
Sampling and sample separation rack
Continuous monitoring of radioactivity in gaseous effluentsbull Automatic monitoring of the alpha- and beta-
radioactive aerosol noble gas and radioiodine concentrations in the air in ventilation ducts and stacks
bull Monitoring of the flow rate temperature and humidity of the gas flow
bull Separation of gaseous effluent into targeted fractions by means of a two-stage filter
bull Reversion of gas after analysis to the ventilation system
Physical characteristics
Particulate (UDA-1AB)bull Silicon specrometric detectors (2 pcs for measure-
ment and for gamma-background compensation) bull Filter tape types LFAS FSLWbull Tape consumption (when continuous operation)
10 m50 days
Measurement range bull Alpha 10-2 divide 2105 Bqm3 bull Beta 10-1 divide 106 Bqm3
Energy range bull Alpha 30 divide 90 MeV bull Beta 005 divide 30 MeV
Noble gas (UDG-1B)bull silicon detectors (2 pcs for measurement and for
gamma-background compensation)
Measurement range bull 104 divide 6109 Bqm3
Energy range bull 008 divide 30 MeV
Iodine (UDI-1B)bull scintillation detectors CsI(Tl) (2 pcs for measure-
ment and for background compensation)
SKGAV STACK MONITOR
Particulate noble gas and iodine monitors rack
Measurement range bull 37 divide 37105 Bqm3
Energy range bull 015 divide 30 MeV
Air flow parameters (UPPVM)Measurement range bull air flow velocity 1 divide 20 msbull air temperature 0 divide +80 ordmСbull air humidity 10 divide 95
Radiation monitoring system SPC ldquoDozardquo
28 29
CONFIGURATOR SOFTWAREMaintenance and set-up softwarebull Set-up and verify RMS monitorsbull Control testing adjustment and repair of RMS
monitorsbull Monitors measurement results archive receive
and View bull Communication through RS-232
RMS WORKSTATION ndash OPERATOR CONSOLEOrganization of interaction of the RMS Server and Monitors
Single monitor console includes vandal-proof key-board amp UPS
Reference standard IEC 61559-1 IEC 61559-2
RMS SOFTWAREData acquisition storing and visual representation RMS monitors measurement resultsbull Ethernet IEEE 8023 networkbull Clientserver architecturebull TCPIP protocolbull Oracle based Data Basebull Supremal by means InSat MasterSCADA
Radiation monitoring system SPC ldquoDozardquo
30 31
Delivery setComposition and modification depend on the tasks to be solved using the RM Rack
The rack which is an integral part of RM Rack accommodatesbull Monitors UDA-1AB UDG-1B UDG-03D UDI-1B
UDGB-01Tbull DBG-S11D Wide range gamma area monitor
BDMG-101 High range gamma area monitor UDMN-100 Neutron area monitor BDRG-52R High range gamma area monitor
bull BI-2 Remote display amp alarm unitbull Pump unit BN-01bull Data processing and transmission unit BOP-1Mbull External alarm BAS or BAS-1sbull Equipment of sampling line (flow meters ball
valves filter holder piping solenoid valve)bull Switchboard (intended for switching of all equip-
ment and transfer of data to the upper level via the unified communication channel)
RM RACK RADIATION MONITORING RACK
The radiation monitoring rack (RM Rack) is designed for continuous monitoring of radiation parameters in premises and technological systems at nuclear facil-ities RM Rack can be used as a structural element of the lower-level of RMS at nuclear power plants and other nuclear facilities that involved in obtaining processing use and storage of radioactive materials
FeaturesContinuous automatic monitoring of the alpha- and beta- radioactive aerosol beta-emitting radioactive gases and radioiodine concentrations in the working air and in the air in stacks and others radiation parameters in the facilities
The stand providesbull Primary processing storage and transmission of
measured and related data into the information channel based on the Ethernet IEEE 8023 inter-face (TCPIP protocol)
bull Transfer of required data to the location where the equipment is installed via technological channels based on RS-232 interface
bull Generation of audible and visual warning alarm signals when the preset thresholds are exceeded
bull Display of received data on the LCD
Radiation monitoring system SPC ldquoDozardquo
32 33Reference standards IEC 60860 ANSIANS-83 ISO 7753
Purposebull Detection and recording of criticality accident
(CA) by measuring the absorbed dose rate of gamma-neutron radiation in the premises of monitored object its comparison with a threshold value and generation of audible and visual signals
bull Automatic collection processing storage and display of measurement data and related infor-mation as visual and graphical representation for operators of nuclear safety service
Functions of the systembull Detection and recording of CA events by con-
tinuous measurement of absorbed dose rate of gamma radiation comparison of measured values with preset thresholds generation of signals to activate the alarm
bull Activation of audible visual alarmbull In the event of CA turning on warning signals
ldquoDO NOT ENTERrdquo at illuminated information pan-els placed at the entrances to the controlled area
Featuresbull Data can be transferred to external data commu-
nication channel using RS-485 interface (DiBus data exchange protocol)
bull Automatic self-testing of detection units BR-04D with display of information about the type of fault
bull Possibility for connecting additional a detection and alarm units
bull Ability to function in general regardless of the functioning of components within the agreed scope of nuclear safety tasks
bull Radiation hardness up to 100 Gy
SRKS-01DCRITICALITY ACCIDENT ALARM SYSTEM
Features of softwarebull Collection of information via RS-485 network
displaying it on the PC monitor transmission to remote users archiving and storage
bull Status monitoring and display of values measured by BR-04D and DBG-S11D in locations as per layout of premises
bull Access to archived data with possibility to gener-ate reports for periods determined by operator
bull Maintenance and archiving of a log of dosimetric measurements data and events along with their time stamps
bull Possibility to transfer data to external users via Ethernet network for integrating of CA into higher level systems
Basic complete setLower level bull Control unit with power supplybull BR-04D detection unitsbull BZS-01D audible alarm unitsbull BSS-01D visual alarm unitsbull SIT-01D illuminated warning signsbull PBZ panels for muting audible alarmbull Network communication module
Additional lower layer devicesbull DBG-S11D wide range gamma area monitor
Upper layer bull CDP central display panelbull Service workstation
RS-485
RS-485
RS-4
85
Audible alarm units BZS-01D
Illuminated warning signs SIT-01D
Detection units BR-04D
Network communication
moduleDBG-S11D wide range gamma area monitor
Panels for muting audible alarm
Control unit with power supply
Visual alarm units BSS-01D
RS-485
RS-485
RS-4
85
Audible alarm units BZS-01D
Illuminated warning signs SIT-01D
Detection units BR-04D
Network communication
moduleDBG-S11D wide range gamma area monitor
Panels for muting audible alarm
Control unit with pow-er supply
Visual alarm units BSS-01D
RS-485
RS-4
85
Audible alarm units BZS-01D
Illuminated warning signs SIT-01D
Detection units BR-04D
Network communication
moduleDBG-S11D wide range gamma area monitor
Panels for muting audible alarm
Control unit with power supply
Visual alarm units BSS-01D
RS-485
RS-485
RS-4
85
Audible alarm units BZS-01D
Illuminated warning signs SIT-01D
Detection units BR-04D
Network communication
moduleDBG-S11D wide range gamma area monitor
Panels for muting audible alarm
Control unit with power supply
Visual alarm units BSS-01D
Ethernet
Central display panel Service workstation
RS-485
RS-485
RS-4
85
BZS-01D audible alarm units
SIT-01D illuminated warning signs
BR-04D detection units
Network communication
moduleDBG-S11D wide range gamma area monitor
PBZ panels for muting audible alarm
Control unit with power supply
BSS-01D visual alarm units
Radiation monitoring system SPC ldquoDozardquo
34 35
ldquoBREEZErdquoHIGH-VOLUME AIR SAMPLER
Physical characteristicsbull Measurement range of air flow rate
250 divide 1200 m3hbull Continuous operation time not less than 24 h
Filter materialsbull High-purity glass fiberbull Pure quartz or cellulosebull Filter fabric FPP-15-15
Electrical characteristicsPower supply bull 220380 V 50 Hz
Interfaces bull RS-485bull Ethernetbull GSMGPRS (option)
Environmental characteristicsTemperature range bull minus 40 divide + 40 ordmC
Relative humidity limit at 35 ordmC bull 95
Atmospheric pressure range bull 840 divide 1067 kPa
Versionsbull Standalone unit bull Part of Environmental Radiation Monitoring
System (ERMS)
Type of detection unitsbull Beta block BDZB-100Lbull DBG-S11D wide range gamma area monitorbull Scintillation spectrometric block
The motor of Air Sampler is controlled by an electronic flow sensor that detects changes in the operators pre-set flow rate caused by changes in temperature barometric pressure and pressure drop due to dust loading on filter media It compensates for these changes by adjusting the motor speed to maintain the pre-set flow ratebull Measurement of parameters of ionizing radiation bull Standalone mode of operation or as the part
of Environmental Radiation Monitoring System (ERMS)
Purposebull Environmental Radiation Monitoring System
(ERMS) in the control and buffer areas of the radia-tion and nuclear facilities
Referencesbull Since the year 2000 the system is successfully
operating the ERMSs at 8 Russian nuclear power plants (about 180 monitoring stations)
bull Since the year 2005 the ERMS is operating in the Moscow (about 40 monitoring stations)
bull Since the year 2005 the regional ERMS is under operation in several Russian Federation regions
Basic complete setMonitoring stations bull Data processing and transmission unit BOP-1TA bull Gamma area monitor DBG-S11D
Central data processing station (CDPS)bull Data processing and transmission unit BOP-1TAbull Server
By requestbull Emergency Response and Crisis Management
Centers for enterprisesbull Regional Emergency Response and Crisis Manage-
ment Centersbull rdquoBreezerdquo High-Volume Air Samplerbull Mobile lab with gamma-survey system rdquoGammandash
sensorrdquo
ldquoATLANT-MrdquoENVIRONMENTAL RADIATION MONITORING SYSTEM
Monitoring system for the continuous radiation monitoring of territories and facilities with the data transmission GSMGPRS network
Data transmission bull GSMGPRS
Power supply bull 220 V 50 Hz
Continuous autonomous operation (at 20 ordmC)bull From built-in battery not less than 5 hoursbull From external battery not less than 24 hours
Operation temperature bull Minus 40 divide +50 ordmC
Operation humidity bull Up to 98
Protection bull IP65
Reference standards Nuclear IEC 61017-11991 IEC 61017-21994
36
Radiation Monitoring Equipment
bull Localization of radioactive contaminationsbull Database with dose rate contaminations
spectra measurement date amp time coordi-nates
bull Work as part of mobile laboratory or as part of Environmental Radiation Monitoring System with real-time data transfer
Physical characteristicsDetector bull Scintillation NaI (Tl) GM counters
Measurement rangebull 01 ndash 107 μSvh
Energy range bull 005 ndash 3 MeV
Operation temperature range bull minus 10 divide +50 ordmС
Electrical characteristics bull Power supply 220 V 50 Hz
ldquoGAMMAndashSENSORrdquoGAMMA-SURVEY SYSTEM
SPC ldquoDozardquoRadiation monitoring equipment
38 39
AREA MONITOR ldquoFREGATrdquoArea Monitor ldquoFregatrdquo is designed for building rela-tively simple and inexpensive radiation monitoring systems at such facilities as radionuclide sources storage areas isotope products warehouses nuclear medicine departments PET centers calibration laboratories where sources of ionizing radiation are used etc
Small scale automated radiation monitoring systems built with ldquoFregatrdquo components featuring audible and visual alarms are matched suitable to meet the regulatory radiation safety requirements
Area monitor ldquoFregatrdquo requires virtually no adjust-ment it is simple and convenient for installation and operation
BPI-1D LOCAL DISPLAY UNIT
Display of monitored parameters values received from external measuring devices
Purposebull Processing and display of values of monitored
parameters on information panel bull Comparison of values of monitored parameters
with thresholdsbull Transfer of monitored parametersrsquo values to
networkbull Generation of alarm in case of exceeding of preset
thresholds including external alarm devices
FeaturesTesting the unit and connected devicesbull Visually on the panelbull Using adjustment software when connected to
PC via USB
Automatic self-testing
The panel displays the following informationbull Diagnostic information about the status of con-
nected devicesbull Current date and timebull Values of measured parametersbull Position of measured values with respect to the
thresholds in the form of scales with green yellow and red zones
bull Time history (trend) for each measured value
Physical characteristicsTemperature range bull minus 10 divide + 50 ordmC
Maximum number of connected devicesbull measuring devices 15bull external audible and visual alarm 15
Display diagonal bull 152 cm (6)
Electrical characteristicsbull Interfaces RS-485bull Power supply 220 V 50 Hz 12 divide 24 V
Mechanical characteristicsbull Protection index IP54bull Paint decontaminable
Overall dimensions weightbull 296x248x118 mm 5 kg
DBG-S11D wide range gamma area monitor
UDMN-100 neutron area monitor
Ethernet RS-485
UDKS-100 gamma and X-ray area monitor
BPI-1D Local display unit
BAS-2 ldquoMicrordquo external visual alarm
BZS-2 ldquoMicrordquo external audible alarm
ldquoImpulsrdquo external display unit
Service workstation
Illuminated warning signs
SPC ldquoDozardquoRadiation monitoring equipment
4140
Continuous automatic monitoring of the gamma- X-ray ambient dose equivalent rate
Physical characteristicsbull Detector tissue-equivalent plastic scintillator
Oslash 45times20 mm
Measurement range bull Dose rate measurement range 01 μSvh divide 1 Svh bull Energy range 0015 divide 10 MeV
Mechanical characteristicsbull Protection index IP65bull Paint decontaminable
Overall dimensions weightbull Oslash72times265 mm 15 kg
UDKS-100 GAMMA AND X-RAY AREA MONITOR
UDMN-100 NEUTRON AREA MONITOR
Physical characteristicsbull detector ndash scintillator ZnS(Ag) Li-6
Measurement range bull 01 μSvh divide 01 Svh
Energy range bull 0025 eV divide 100 MeV
Temperature range bull minus 45 divide +50 ordmC
Electrical characteristicsbull Interfaces RS-485
Mechanical characteristicsbull Protection index IP 65bull Paint decontaminable
Overall dimensions weight bull 428times258times347 mm 115 kg
Continuous automatic monitoring of the neutron-radiations ambient dose equivalent ratebull Spherical polyethylene moderator Oslash 239 mm
MEASURING UNITS
DBG-S11D WIDE RANGE GAMMA AREA MONITOR
Continuous automatic monitoring of the gamma- ambient dose equivalent rate
Physical characteristicsbull Detector ndash GM counters
Measurement rangebull DBG-S11D 01 μSvh divide 10 mSvhbull DBG-S11D-01 01 μSvh divide 10 Svhbull DBG-S11D-02 01 μSvh divide 100 Svh
Energy rangebull 005 divide 30 MeV
Temperature range bull minus 40 divide +50 ordmC
Electrical characteristicsbull Interfaces RS-485 USB
Mechanical characteristicsbull Protection index IP 68bull Paint decontaminable
Overall dimensions weightbull DBG-S11D Oslash 68times141 mm 065 kg bull DBG-S11D-01 Oslash 68times179 mm 07 kgbull DBG-S11D-02 Oslash 68times179 mm 07 kg
Versionsbull DBG-S11Dbull DBG-S11D-01bull DBG-S11D-02
Reference standards Nuclear IEC 60846 IEC 60532 EMC IEC 61010 IEC 61000-6-2 Seismic IEC 60980
SPC ldquoDozardquoRadiation monitoring equipment
4342
ALARM UNITS
Generation visual signals of the excess of preset thresholds
Physical characteristicsLength of communication cablebull up to 1200 mbull Alarm Visual alarm green yellow red
Electrical characteristicsbull Power supply +12 V
Mechanical characteristicsbull Protection index IP 23
Overall dimensions weight 160times84times41 mm 02 kg
BAS-2 ldquoMICROrdquo EXTERNAL VISUAL ALARM
Generation audible signals of the excess of preset thresholds
Physical characteristicsLength of communication cablebull up to 1200 mbull Audible alarm 80 divide 100 dB at a distance of 1 m
Electrical characteristicsbull Power supply +12 V
Mechanical characteristicsbull Protection index IP 23
Overall dimensions weight 160times84times41 mm 02 kg
BZS-2 ldquoMICROrdquo EXTERNAL AUDIBLE ALARM
Physical characteristicsLength of communication cablebull up to 1200 m
Electrical characteristicsbull Power supply 220 V 50 Hz
Mechanical characteristicsbull Protection index IP 23
Overall dimensions weight bull 330times110times20 mm 05 kg
Physical characteristicsLength of communication cablebull up to 1200 m
Character height bull ldquoImpuls-910-Rrdquo 100 mmbull ldquoImpuls-915-D4Srdquo 150 mmbull ldquoImpuls-927-D4Srdquo 270 mm
Operating temperature rangebull ldquoImpuls-910-Rrdquo 0 divide +50 degCbull ldquoImpuls-915-D4Srdquo ldquo-727-D4Srdquo minus 40 divide +50 degC
Electrical characteristicsbull Power supply 220 V 50 Hz
Mechanical characteristicsProtection index bull ldquoImpuls-910-R IP 44bull ldquoImpuls-915-D4Srdquo ldquo-727-D4Srdquo IP 65
Overall dimensions weight bull ldquoImpuls-910-Rrdquo 400times160times60 mm 3 kgbull ldquoImpuls-915-D4Srdquo 815times250times80 mm 5 kgbull ldquoImpuls-927-D4Srdquo 1250times330times80 mm 5 kg
ILLUMINATED WARNING SIGNS
ldquoIMPULSrdquo EXTERNAL DISPLAY UNIT
SPC ldquoDozardquoRadiation monitoring equipment
4544
Individual threshold setting for each measurement channel
Continuous area and process monitoring
Collect amp display data from two measurement chan-nels (units with RS-485 or analog pulses)
Audible and visual alarms on exceeding preset thresholds or status of connected devices
Individual threshold setting for each measurement channel
Switching on the external alarm or executive devices when any threshold is exceeded
The wide panel displays the following information bull Values of measured parameters as min-1∙cm-2
s-1∙cm-2 μSvhbull Diagnostic information about the status of con-
nected devicesbull Current date and timebull Position of measured values with respect to the
thresholds in the form of scales with green yellow and red zones
bull Time history (trend) for each measured value
Physical characteristics Measurement range bull Count rate up to 107 CPM (170 kHz)
Operating temperature range bull minus 20 divide +50 ordmC
Electrical characteristics bull Power supply 220 V bull Interfaces USB
Mechanical characteristics bull Protection index IP 65 bull Overall dimensions weight 222times164times73 mm
40 kg
UIM-3D AREA MONITOR COUNT RATE METER
Measurement of alpha radiation flux density
Detector unit BDZA-100 (70 cm2) Measurement range 01 divide 104 min-1∙cm-2
Detector unit BDZA-100B (300 cm2) Measurement range 01 divide 2103 min-1∙cm-2
Measurement of beta radiation flux density
Detector unit BDZB-100 (28 cm2) Measurement range 10 divide 105 min-1∙cm-2
Detector unit BDZB-100L (30 cm2) Measurement range 10 divide 104 min-1∙cm-2
Detector unit BDZB-11D (84 cm2) Measurement range 5 divide 15∙104 min-1∙m-2
OPTIONAL PROBESMeasurement of gamma radiation flux density
Detector units BDEG-03 Measurement range 4 divide 2000 s-1∙cm-2
Detector unit UDKG-100 for operation in the rocks ore liquid media and sludge Measurement range 40 divide 8000 s-1∙cm-2
Measurement of the ambient dose equivalent rate
Detector unit DBG-S11D Measurement range 01 μSvh divide 100 Svh
Measurement of neutron radiation ambient dose equivalent rate
Detector unit BDMN-100 Measurement range 01 μSvh divide 01 Svh
SPC ldquoDozardquoRadiation monitoring equipment
46 47Reference standards Nuclear IEC 61526
Measurement of gamma-radiation personal dose equivalent Hp(10)bull Stand-alone dosimeter or composed of dosimetric
system onebull Audible and visual alarmbull Large memory dose accumulation historiesbull Exclusion of unauthorized intervention in dosim-
etry operation
DKG-05D PERSONAL GAMMA DOSIMETER
Physical characteristicsDetectors bull Silicon
Measurement range bull Dose rate 1 μSvh divide 10 Svhbull Dose 01 μSv divide 15 Sv
Energy range bull 005 divide 30 MeV
Electrical characteristicsbull Power supply rechargeable NiMH battery 1
alcaline battery (type AAA)
Operation timebull Till recharging not less 400 hoursbull With one set batteries not less 1000 hours
Mechanical characteristicsOverall dimensions weight bull 47times26times87 mm (with clip) 70 g
Environmental characteristicsbull IP65bull Temperature range minus 20 divide +45 ordmCbull Humidity up to 98 at 35 ordmCbull Shock vibration and drop resistant
Alarmbull Excess of alarm thresholdsbull Warnings of self-test failure and battery discharge bull Audible alarm 80 dB at 40 cmbull Visual alarm blinking LED
Relative equipmentbull One dosimeter charger ZU-1Mbull Chargestorage cassetes KZU-28KZU-56bull ldquoSmart chargingrdquo feature extends battery life timebull DKG-05D reader US-05bull DKG-05D system reader DVS-01D
Reader-PC interfacebull US-05 USB bull DVS-01D Ethernet
KZU-28
Physical characteristicsDetectors bull Silicon Li-6
Gamma measurement range bull Dose rate 1 μSvh divide 10 Svhbull Dose 01 μSv divide 15 Sv
Gamma energy range bull 005 divide 60 MeV
Neutron measurement range bull Dose rate 1 μSvh divide 2 Svhbull Dose 20 μSv divide 15 Sv
Neutron energy range bull 0025 eV divide 20 MeV
Electrical characteristicsPower supply bull Rechargeable NiMH batterybull Operatiion time till recharging not less 200 hours
Mechanical characteristicsOverall dimensions weight bull 47times26times87 mm (with clip) 70 g
Environmental characteristicsbull IP65bull Temperature range minus 20 divide +40 ordmCbull Humidity up to 75 at 30 ordmCbull Shock vibration and drop resistant
Alarmbull Excess of alarm thresholds bull Warnings of self-test failure and battery discharge bull Audible alarm 80 dB at 40 cmbull Visual alarm blinking LED
Relative equipmentbull One dosimeter charger ZU-1Mbull Chargestorage cassetes KZU-28 KZU-56bull ldquoSmart chargingrdquo feature extends battery life timebull DVS-02D reader UZS-01Sbull DVS-02D system reader DVS-01D
Reader-PC interfacebull UZS-01S USB bull DVS-01D Ethernet
UZS-01DReference standards Nuclear IEC 61526
DVS-02D GAMMA-NEUTRON PERSONAL ELECTRONIC DOSIMETER
Measurement of gamma- and neutron radiations personal dose equivalent Hp(10)bull Stand-alone dosimeter or composed of dosimetric
system onebull Audible and visual alarmbull Large memory dose accumulation historiesbull Exclusion of unauthorized intervention in dosim-
etry operationbull Both albedo thermal neutrons and intermediate
fast neutrons registrationbull Usable in the fields of Pu(Be) Po(Be) Cf and other
neutron sources as well as near nuclear reactors without neutron spectrum estimation
SPC ldquoDozardquoRadiation monitoring equipment
48 49
Dosimeters DVG-03D
DVGI-8D NEW PEN-TYPE PERSONAL IONIZATION CHAMBER DOSIMETERS
Measurement of personal dose equivalent Hp(10) of gamma and X-ray radiationbull Hp(10) of continuous and pulsed gamma and
X-ray radiation bull Electronic reader KSU-1bull Dosimeter DVG-03D with electronic ID bull Personal dose histories in the readerrsquos memorybull Readerrsquos connection with PC for database main-
tenance
Physical characteristicsDetector bull Ionization chamber
Measurement range bull 001 mSv divide 25 mSv
Energy range bull 0015 divide 25 MeV
Temperature range bull Reader KSU-1 +10 divide +50 ordmСbull Dosimeter DVG-03D minus 40 divide +50 ordmС
Electrical characteristicsPower supply bull Reader KSU-1 220 V 50 Hz built-in batteries bull Dosimeter DVG-03D four batteries CR 1025 bull Batteries life 3 yearsbull Readers interfaces RS-232USB 20
Mechanical characteristicsOverall dimensions weightbull Dosimeter DVG-03D Oslash 18times126 mm 005 kgbull Reader KSU-1 235times232times125 mm 28 kg
Reference standards Nuclear IEC 62387-1
DKG-02U ldquoARBITERrdquo WIDE RANGE GAMMA-DOSIMETER
Physical characteristicsDetectors bull GM counters
Measurement rangebull Dose-rate 01 μSvh divide 3 Svhbull Dose 1 μSv divide 100 Sv
Energy range bull 005 divide 3 MeV
Electrical characteristicsbull Power supply 2 alcaline batteries (type AA)bull Batteries life not less 200 hours
Mechanical characteristicsOverall dimensions weight bull 152times82times32 mm 03 kg
Environmental characteristicsbull Temperature range minus 20 divide +50 ordmCbull Humidity up to 90 at +25 ordmCbull Shock vibration and drop resistant
Reference standards Nuclear IEC 60846
Measurement of gamma radiation ambient equiva-lent dose H(10) and dose rate H(10)bull Audible signals (clicks) for radiation condition
estimationbull Analog scale for search modebull Audible and visual alarms of the excess of preset
dose and dose rate thresholds bull Shock-resistant water-proof easy decontamina-
tion casebull 100 measurement results memory with date and
time of measurementbull Indication of total dose accumulated during
exploitation time bull Indication of measurement result statistical
uncertainty
SPC ldquoDozardquoRadiation monitoring equipment
50 51
Physical characteristicsDetectors bull GM counter
Measurement rangebull Dose-rate 01 μSvh divide 3 mSvhbull Dose 1 μSv divide 02 Sv
Energy range bull 005 divide 3 MeV
Temperature range bull Minus 20 divide +50 ordmC
Electrical characteristicsbull Power supply 2 alcaline batteries 15 V (type AA)bull Batteries life not less 200 hours
Mechanical characteristicsOverall dimensions weight bull 122times74times29 mm 025 kg
Reference standards Nuclear IEC 60846
DKG-07D ldquoDROZDrdquoGAMMA-DOSIMETER
Measurement of gamma radiation ambient equiva-lent dose H(10) and dose rate H(10)bull Two independent measurement channels dose
and dose ratebull Audible signals (clicks) for radiation condition
estimationbull Continuous measurement with updating meas-
urement resultbull Measurement result can be obtained with any
desired statistical uncertainty (error)bull Automatic restart when radiation level sharply
changesbull Indication of statistical uncertainty (error) during
measurement process
Continuous measurement with updating measure-ment result
Automatic restart when radiation level sharply changes bull Gamma dose H(10) and dose-rate H(10) meas-
urementbull Beta and gamma contamination surveybull Indication of statistical uncertainty during the
measurementbull Continuous measurement with accuracy increas-
ing with time bull Automatic restart triggered by change of gamma
dose-ratebull Compensation of gamma count rate while meas-
uring beta radiationbull Indication of battery charge levelbull Audible signal of the excess of preset threshold
Physical characteristicsDetectors bull GM counter
Measurement range bull Dose-rate 01 microSvh divide 20 mSvhbull Dose 1 microSv divide 100 Svbull Beta flux density (for Sr-90+Y-90)
10 divide 105 cm-2 min-1
Energy range bull Gamma 005 divide 3 MeVbull Beta 01 divide 3 MeV
Temperature range bull Minus 20 divide +50 ordmC
MKS-15D ldquoSnegirrdquo backside
MKS-15D ldquoSNEGIRrdquoMULTI ndash PURPOSE RADIATION SURVEY METER
Reference standards Nuclear IEC 60846 IEC 60325
Electrical characteristicsbull Power supply 2 alcaline batteries (type AA)bull Battery life not less 400 hours
Mechanical characteristicsOverall dimensions weight bull 124times72times35 mm 035 kg
SPC ldquoDozardquoRadiation monitoring equipment
52 53
Physical characteristicsDetectorbull GM counter
Measurement range bull 01 μSvh divide 20 mSvh
Energy range bull 005 divide 30 MeV
Threshold setting range bull 03 μSvh divide 20 mSvh
Step change of the thresholdbull In the range 03 divide 10 μSvh with the step
001 μSvhbull In the range 10 divide 100 μSvh with the step
01 μSvhbull In the range 100 divide 2000 μSvh with the step
10 μSvh
Electrical characteristicsPower supply bull 220 V 50 Hz bull Relay output
Mechanical characteristicsProtection index bull IP 40
Overall dimensions weight bull 226times120times75 mm 07 kg
Alarmbull Sound alarm 80 divide 100 dBA at distance 1 mbull Visual alarm redbull Connection of the external alarm signaling unit
Reference standards Nuclear IEC 60846 IEC 60532
Continuous automatic monitoring of the ambient dose equivalent rate bull Measurement of gamma dose rate H(10)bull Audible and visual alarm signals for preset
thresholdsbull Switching on the external signaling or executive
devices
SRPS-05D GAMMA MONITOR
Measurement ofbull Gamma and X-ray personal dose equivalent
Hp(10)bull Neutron personal dose equivalent Hp(10)bull Lens dose equivalent Hp(3)bull Skin dose equivalent Hp(007)bull TLD reader day-to-day tests using built-in LEDbull No needs nitrogen for heating
Physical charachteristicsDetectors bull 7LiF Mg Ti (gamma beta)bull 6LiF Mg Ti (neutron)
Gamma and X-ray Hp(10) Measurement range bull 500 μSv divide 10 Sv
Energy range bull 0015 divide 30 MeV
Neutron Hp(10)Measurement range bull 01 mSv divide 100 mSv
Energy range bull 0025 eV divide 10 MeV
Beta and photons Hp(007) Hp(3) Measurement range bull 2 mSv divide 100 Sv
Energy range bull Beta 025 divide 35 MeVbull Photons lt15 keV
Mechanical characteristicsDosimeters overall dimensions weight bull Gamma Hp(10) DTL-2 holder - 62times26times16 mm
16 gbull DTU holder - 42times28times18 mm 8 gbull Lens Hp(3) face skin Hp(007) Oslash 32times16 mm 9 gbull Finger skin Hp(007) 90times20times2 mm 1 gbull Neutron gamma Hp(10) 48times40times20 mm 30 g
Reference standards Nuclear IEC 61066
DTL-2 DTU-2
MKD (A-type) DVNG-M
DOZA-TLD MULTIPURPOSE TLD SYSTEM
SPC ldquoDozardquoRadiation monitoring equipment
54 55
Continuous and pulsed gamma and X-ray dose H(10) and dose-rate measurementbull Alpha beta and gamma contamination surveybull Neutron dose H(10) and dose-rate measurementbull Gamma radiation flux density in boreholes and
liquid media measurement
Electrical characteristicsPower supply bull UIK-05 four C-size batteriesbull UIK-05-01 rechargeable batterybull UIK-06 rechargeable battery
Interfaces bull RS-232bull USB (via adapter)
bull Detector type automatic determination and corre-sponding measurement modes selection
bull Alarm threshold settings ndash for dose dose-rate alpha and beta contaminations
bull ldquoDetectrdquo and ldquoLocaterdquo modes for survey probes
Reference standards Nuclear IEC 60846 IEC 60325 IEC 61005 IEC 62363
Case
UIK-06 control unit165times78times48 mm 03 kg
DKS-96UNIVERSAL RADIATION SURVEY METER
UIK-05 control unit202times86times90 mm 10 kg
BDZA-96
BDZA-96B
BDZA-96M
BDZA-96S
BDZA-96T
EXTERNAL PROBES ALPHAALPHA BDZA-96Detector bull ZnS(Ag) 70 cm2
Measurement range (for Pu-239)bull 01 divide 104 min-1cm-2
Overall dimensions weightbull Oslash 130times240 mm 11 kg
ALPHA BDZA-96BDetector bull ZnS(Ag) 300 сm2
Measurement range (for Pu-239)bull 01 divide 2103 min-1cm-2
Overall dimensions weightbull Oslash 230times290 mm 40 kg
ALPHA BDZA-96MDetector bull ZnS(Ag) 10 сm2
Measurement range (for Pu-239)bull 01 divide 105 min-1cm-2
Overall dimensions weightbull Oslash 65times240 mm 09 kg
ALPHA BDZA-96SDetector bull ZnS(Ag) 30 сm2
Measurement range (for Pu-239)bull 01 divide 5104 min-1cm-2
Overall dimensions weightbull Oslash 90times240 mm 10 kg
ALPHA BDZA-96TDetector bull Silicon 5 сm2
Measurement range (for Pu-239)bull 01 divide 106 min-1cm-2
Overall dimensions weightbull Oslash 50times60 mm 015 kg
SPC ldquoDozardquoRadiation monitoring equipment
56 57
BETA BDZB-96Detector Scintillator 28 сm2
Measurement range (for Sr-90+Y-90)bull 10 divide 105 min-1cm-2
Energy rangebull 03 divide 30 MeV
Overall dimensions weightbull Oslash 90times230 mm 09 kg
BETA BDZB-99Detector bull GM counter 30 сm2
Measurement range (for Sr-90+Y-90)bull 20 divide 104 min-1см-2
Energy rangebull 012 divide 30 MeV
Overall dimensions weightbull Oslash 88times80 mm 04 kgbull Telescopic pole length 07 m
BETA BDZB-96BDetector bull GM counter 80 сm2
Measurement range (for Sr-90+Y-90)bull 3 divide 104 min-1сm-2
Energy rangebull 012 divide 30 MeV
Overall dimensions weightbull 150times200times110 mm 15 kg
BETA BDZB-96Sbull Detector GM counter 15 сm2
Measurement range (for Sr-90+Y-90)bull 10 divide 3104 min-1cm-2
Energy rangebull 012 divide 30 MeV
Overall dimensions weightbull Oslash 65times65 mm 03 kgbull Telescopic pole length 07 m
BDZB-96
BDZB-99
BDZB-96B
BDZB-96S
EXTERNAL PROBES BETA
GAMMA BDKS-96BDetector bull Tissue-equivalent scintillator Oslash 45times20 mm
Measurement rangebull Dose rate H(10) 01 μSvh divide 1 Svhbull Dose H(10) 01 μSv divide 10 Sv
Energy rangebull 0015 divide 10 MeV
Overall dimensions weightbull Oslash 60times250 mm 085 kg
GAMMA AND BETA BDKS-96SDetector bull Double GM counters
Measurement rangebull Gamma dose rate H(10) 01 μSvh divide 1 mSvhbull Gamma dose H(10) 01 μSv divide 10 Svbull Beta 10 divide 3104 min-1cm-2
Energy rangebull Gamma 005 divide 3 MeVbull Beta 012 divide 3 MeV
Overall dimensions weightbull Oslash 80times80 mm 035 kgbull Telescopic pole length 07 m
GAMMA BDMG-96Detector bull GM counters
Measurement rangebull Dose rate H(10) 01 μSvh divide 10 Svhbull Dose H(10) 01 μSv divide 10 Sv
Energy range bull 005 divide 3 MeV
Overall dimensions weightbull 40times250 mm 05 kgbull Telescopic pole length 07 m 4 m (by request)
EXTERNAL PROBES GAMMA
BDKS-96B
BDMG-96
BDKS-96S
SPC ldquoDozardquoRadiation monitoring equipment
58 59
GAMMA-SEARCH BDVG-96Detector bull Scintillator NaI(Tl) Oslash 63times63 mm
Measurement rangebull Flux density measurement range 4 divide 2000 s-1cm-2
bull Dose rate H(10) for Cs-137 01 divide 30 μSvhbull Sensitivity for Cs-137 3000 (pulsess-1)( μSvh-1)
Overall dimensions weightbull Oslash 88times400 mm 20 kgbull Modular pole length 16 m
GAMMA-SEARCH BDPG-96Detector bull Scintillator NaI(Tl) Oslash 25times40 mm
Measurement rangebull Flux density measurement range 10 divide 8000 s-1cm-2
bull Dose rate H(10) for Cs-137 01 divide 100 μSvhbull Sensitivity for Cs-137 500 (pulsess-1)( μSvh-1)
Overall dimensions weightbull 50times190times480 mm 10 kgbull Telescopic pole length 07 m
GAMMA-SEARCH BDPG-96MDetector bull Scintillator NaI(Tl) Oslash 18times30 mm
Measurement rangebull Flux density measurement range 10 divide 24000 s-1cm-2
bull Dose rate H(10) for Cs-137 01 divide 300 μSvhbull Sensitivity for Cs-137 200 (pulsess-1)( μSvh-1)
Overall dimensions weightbull Oslash 35times320 mm 05 kgbull Telescopic pole length 07 or 38 m
EXTERNAL PROBES GAMMA
BDVG-96
BDPG-96M
BDPG-96
EXTERNAL PROBESGAMMA BDKG-96 STAINLESS STEEL CASING FOR GEOLOGIC APPLICATIONS WELL LOGGINGDetector bull Scintillator NaI(Tl) Oslash 18times30 mm
Measurement rangebull Flux density measurement range 10 divide 105 s-1cm-2
bull Dose rate H(10) for Cs-137 5 divide 2104 μRhbull Sensitivity for Cs-137 200 (pulsess-1)( μSvh-1)
Overall dimensions weightbull Oslash 38times535 mm 36 kgbull Cable length 10 divide 1000 m
NEUTRON BDMN-96Detector bull Scintillator with ZnS(Ag)
Measurement rangebull Dose rate H(10) 01 μSvh divide 01 Svhbull Dose H(10) 01 μSv divide 10 Sv
Energy range bull 0025 eV divide 10 MeV
Overall dimensions weightbull Detector Oslash 54times200 mm 08 kgbull Moderator Oslash 245 mm 73 kg
NEUTRON-SEARCH BDKN-96Detector bull He-3 counter in polyethilene moderator
Measurement rangebull Dose rate H(10) for Pu-Be 01 μSvh divide 01 Svhbull Dose H(10) for Pu-Be 01 μSv divide 10 Sv
Energy range bull 0025 eV divide 14 MeV
Overall dimensions weightbull 295times142times100 mm 225 kg
BDKG-96M
BDMN-96
BDKN-96
SPC ldquoDozardquoRadiation monitoring equipment
60 61
bull No gas supply neededbull Clothing control detachable right hand detector bull Alpha detector optional connection bull Numeric and color (red green) indication of
control resultsbull LED sensor of hand-foot positioning for start of
measurementbull Automatic compensation of gamma background
and contamination of detectorbull Audible alarm signals of the excess of preset
thresholdsbull Measurement value indication min-1cm-2 or
Bqсm2
Reference standards Nuclear IEC 61098
RZB-05D HAND-FOOT-CLOTHING MONITOR
Physical characteristicsDetectors bull Gamma beta - GM countersbull Alpha - scintillatior ZnS(Ag)
Detecting nuclidesbull Alpha Pu-239 U-234 U-238bull Beta Sr-90+Y-90 F-18 Cs-137 Co-60 Tс-99 O-15
N-13 Sr-89 C-11 I-131 Na-22 Ru-106+Rh-106 Tl-204
bull Gamma Tc-99m I-123
Efficiencybull Alpha
Pu-239 40 U-234 25U-238 15
bull Beta Sr-90 +Y-90 40
Measurement range bull Alpha 1 divide 103 min-1cm-2 bull Beta 10 divide 103 min-1cm-2
bull Gamma 5103 divide 5106 min-1cm-2
Energy range bull Alpha 30 divide 80 MeV bull Beta 008 divide 35 MeV bull Gamma 005 divide 30 MeV
Operation temperature range bull Minus 10 divide +50 ordmС
Electrical characteristicsbull Power supply 220 V 50 Hz
Mechanical characteristicsOverall dimensions weight bull 740times750times1180 mm 45 kg
Versionsbull Withwithout alpha detectorbull Indication (min-1cm-2 ) or (Bqсm2)bull Detectors overall dimensions smbull Hand 178 х 235bull Foot 185 х 436
Whole body contamination monitor RZBA-04-04Mbull No gas supply neededbull Compensation for background gamma radiation
and contamination of detector unitsbull Individual threshold setting for each measure-
ment channelbull Visible and audible alarms ldquoCONTAMINATIONrdquo and
ldquoCLEANrdquo bull Indication of contaminated body parts on the
panel with image of the bodybull Optional remote alpha-detector
Physical characteristicsDetectors bull Beta - GM counters scintillatorsbull Alpha - scintillatior ZnS(Ag)
Measurement range bull Beta 5 divide 15000 min-1cm-2
bull Alpha 01 divide 10000 min-1cm-2
Energy range bull Beta 015 divide 25 MeV bull Alpha 40 divide 56 MeV
Operation temperature range bull +5 divide +50 ordmС
Electrical characteristicsPower supply bull 220 V 50 Hz
Interfaces bull RS-232bull RS-485
Mechanical characteristicsOverall dimensions weight bull 2650times940times930 mm 310 kg
Versionsbull Withwithout alpha detectorbull Indication (min-1cm-2 ) or (Bqсm2)
Reference standards Nuclear IEC 61098
RZBA-04-04MWHOLE BODY CONTAMINATION MONITOR
SPC ldquoDozardquoRadiation monitoring equipment
62 63
RZA-05DALPHA HAND-MONITOR
bull No gas supply needed bull Numeric and color (red green) indication of
control resultsbull LED sensor of hand- positioning for start of
measurementbull Audible alarm signals of the excess of preset
thresholdsbull Measurement value indication min-1cm-2 or
Bqсm2
Physical characteristicsDetectors alpha - scintillatior ZnS(Ag)
Efficiencybull Pu-239 20 bull U-234 14bull U-238 8
Measurement range bull 05 divide 105 min-1cm-2
Energy range bull 41 divide 90 MeV
Operation temperature range bull minus 10 divide +50 ordmС
Electrical characteristicsPower supply bull 220 V 50 Hz
Mechanical characteristicsOverall dimensions weight no more bull 740times1400times1450 mm 70 kg
Reference standards Nuclear IEC 61098
bull Simultaneous measurement of alphabeta activi-ties in the sample
bull Active shielding anti-coincidence background subtraction using GM counters
bull Lead shielding 30 mm
UMF-2000 LOW LEVEL ALPHA- BETA- COUNTER
Physical characteristicsDetectors bull Silicon specrometric detector 500 or 1000 mm2
Measurement range bull Alpha 001 divide 1000 Bq bull Beta 01 divide 3000 Bq
Energy range bull Alpha 35 divide 80 MeV bull Beta 005 divide 35 MeV
Electrical characteristicsPower supply bull 220 V 50 Hz
Interfaces bull RS-232bull USB
Mechanical characteristicsOverall dimensions weight bull 337times286times190 mm 22 kg
Versionsbull Detector area 500 mm2
bull Detector area 1000 mm2
UMF-2000 Detector area 1000 mm2
UMF-2000 Detector area 500 mm2
SpectraDec software for alpha-spectrometric measurements
SPC ldquoDozardquoRadiation monitoring equipment
64 65
DRK DOSE AREA PRODUCT METER
DRK-1bull Diagnostic reference level (DRL) of patients
determinationbull Suitable for all basic types of x-ray machines
Physical characteristicsDetector bull Plane-parallel ionization chamber
Measurement range bull 1 divide 104 cGycm2
Electrical characteristicsPower supply bull 220 V 50 Hz
DRK-1M-CTbull Measuring of dose length product
Physical characteristicsDetector bull Pencil Ionization Chamber
Measurement rangebull 05 divide 109 microGym
DRK-1Mbull Measuring of air kerma on sectional area of the
X-ray beam productbull Measuring of air kerma rate on area productbull Measuring of air kerma ratebull Measuring of air kerma
Physical characteristicsDetector bull Plane-parallel ionization chamber
Measurement rangebull 01 divide 109 microGym2
bull 06 divide 6104 microGym2cbull 30 divide 9105 microGycbull 30 divide 9991011 microGyReference standard IEC 60580 2003
bull Measurement of strontium-90 in the foodstuffs agricultural products etc
bull Measurement of gross beta activity in samplebull Self tests using built-in LED
ldquoPROGRESS-BETArdquo SCINTILLATION BETA SPECTROMETER
Physical characteristicsDetector bull Plastic scintillator Oslash70x10 mm
Sample bull Plate Oslash70 mmbull Weight up to 15 g
Energy range bull 02 divide 30 MeV
Minimum detectable activity of Sr-90 in a 10 g sample on a standard planchet Bqsamplebull In case of absence of K-40 in the sample 01 Bqbull In case the activity of K-40 till 5 Bqg 05 Bq
Electrical characteristics Interface bull USB
Mechanical characteristicsWeight bull No more 50 kg
Complete setBasic complete setbull Detector unit with plastic scintillator integrated
power supply amplifier ADC bull Lead shielding bull ldquoProgressrdquo software bull Сheck source for energetic calibration (Sr-90-Y-90) bull Planchet Oslash 70 mm (5 items) bull Sample dencification device bull Procedure manual for measurement of radio-
nuclidesrsquo activity using the scintillation beta spec-trometer ldquoProgressrdquo
Optional equipment and servicebull Personal computer and printer bull Calibrations for radionuclides not included in the
main library of radionuclides
Progress-Beta
Reference standards IEC 61562
SPC ldquoDozardquoRadiation monitoring equipment
66 67
bull Measurement of gamma activity in foodstuffs soil samples and others environmental objects
bull Identification of radionuclides in the sample bull Automatic correction for sample density bull Self-tests using built-in LED
ldquoPROGRESS-GAMMArdquoSCINTILLATION GAMMA SPECTROMETER
Physical characteristicsDetector bull NaI (Tl) Oslash63times63 mm
Validated measurement geometries bull Marinelli beakers (1 liter) Petri dishes (Oslash90 mm)
etc
Energy range bull 02 divide 30 MeV
Minimum detectable activity Bqsamplebull Cs-137 3 Bqbull Th-232 7 Bqbull Ra-226 8 Bq bull К-40 40 Bq
Electrical characteristics Interface bull USB
Mechanical characteristicsWeight bull No more 120 kg
Complete setBasic complete setbull Scintillation detector unit with NaI (Tl) detector
with integrated power supply amplifier and ADC bull Lead shielding 50 mm bull ldquoProgressrdquo software bull Сheck source for energy calibration (Cs-137 +
K-40)bull Marinelli beakers - 1 liter (5 items) bull Petri dishes Oslash 90 mm (5 items) bull Procedure manual for measurement of activity
of radionuclides using the scintillation gamma spectrometer ldquoProgressrdquo
Optional equipment and servicebull Kit for radon measurements including calibration
of ldquoIC-63rdquo geometry for counting the charcoal samples
bull Personal computer and printer bull Calibrations for user defined geometries bull Calibrations for radionuclides not included in the
main library of radionuclides
Progress-Gamma
Reference standards IEC 61563
ldquoPROGRESS-G(P)rdquoPORTABLE SCINTILLATION GAMMA SPECTROMETERbull Field measurements of gamma activity in environ-
mental objects without sampling (4π geometry)bull Laboratory measurement of gamma activity in
foodstuffs soil samples and others environmental objects
bull Identification of radionuclides in the sample bull Automatic correction for sample densitybull Tests using built-in LED
Physical charachteristicsDetector bull NaI (Tl) Oslash45times50 mmbull Lead shielding 20 mm
Validated measurement geometries bull Marinelli beakers (05 liter) Petri dishes (Oslash90 mm)
etc
Energy range bull 02 divide 30 MeV
Minimum detectable activity in 05-litre Marinelli beaker bull Cs-13710 Bqkgbull К-40100 Bqkgbull Ra-22618 Bqkg bull Th-23216 Bqkg
Minimum detectable activity in 30 min (4π geometry) bull Cs-137 2 Bqkgbull К-40 30 Bqkgbull Ra-226 4 Bqkg bull Th-232 3 Bqkg
Electrical characteristicsPower supply bull Rechargeable batterybull 220 V 50 Hz
Interface bull USB RS-232
Weight bull No more than 60 kg
Complete setBasic complete setbull Scinttillation detector unit with NaI(Tl) bull ldquoProgressrdquo softwarebull Сontrol unit ldquoSputnikrdquo for aquisition and analisys
of spectra with built-in memory for spectral databull Casebull Lead shielding (2 cm) for laboratory usebull 05-litre Marinelli beakers ndash 5 itemsbull Na-22 check sourcebull Power adapter BPS-01bull Operation manualbull Procedure manual for measurement of activity
of radionuclides using the scintillation gamma spectrometer ldquoProgressrdquo
Optional equipment and servicebull Kit for radon measurements with charcoalbull Built-in dose rate meterbull Additional memory (RAM) for storage of 64
spectrabull Additional power adapterbull Notebook and printer
Progress-Gamma
Reference standards IEC 61563
SPC ldquoDozardquoRadiation monitoring equipment
68 69
Physical characteristicsDetectorbull Scintillation detector ZnS (Oslash 60 mm)
Samplebull Thin sample - diameter up to 70 mm bull Preparation technique - electro-depositionbull Thick sample - diameter 70 mm weight
200300 mg bull Preparation technique - application of powders
(prepared by radiochemical concentration by water evaporation or by pounding of mineral samples) onto a planchet with the help of spirit
Energy rangebull 15 divide 8 MeV
Minimum detectable activitybull Thin samples no more than 910-3 Bqsamplebull Thick samples no more than 180 Bqkg
Mechanical characteristicsOverall dimensions weightbull 195times120times210 mm 34 kg
Complete setBasic complete setbull Alpha radiometer ldquoProgress-ARrdquobull Check source (uranium isotopes)
Set of accessoriesbull Procedure manual for measurements of radi-
oactivity using scintillation alpha radiometer ldquoProgress-ARrdquo
bull ldquoProgressrdquo software
ldquoProgress-ARrdquo
bull Measurement of gross activity of alpha emitting radionuclides in thin samples
bull Measurement of gross activity of alpha emitting radionuclides in thick samples
bull Measurement of activity deposited on aerosol filters
ldquoPROGRESS-ARrdquoALPHA RADIOMETER
Several fixed positions of the detector enable to perform measurements in various geometries and to estimate the content ofbull Cs-137 in the whole bodybull I-131 in thyroidbull Co-60 Cs-137 Mn-54 Cr-51 in lungsbull Database for storage of measurement data and
resultsbull Uncertainty calculations based on measurement
databull Self tests using built-in LED
ldquoPROGRESSrdquo WHOLE BODY COUNTER
Physical characteristicsDetectorbull scintillation detector NaI (Tl) Oslash63times63 mm
Energy rangebull 02 divide 28 MeV
Minimum detectable activitybull By Cs-137 in the whole body - 1200 Bqbull By I-131 in thyroid - 100 Bqbull By Co-60 Cs-137 Mn-54 Cr-51 in lungs - 200 Bq
Mechanical characteristicsWeight bull No more than 120 kg
Complete setBasic complete setbull Collimator with rotator and holderbull Detector with incorporated ADCbull Patient chair and table for collimatorbull Check source Na-22bull Procedure manual for lifetime measurement of
gamma-emitting radionuclidesrsquo activity in human body using the gamma-spectrometer of human radiation ldquoProgressrdquo
bull laquoProgressraquo software
Optional equipment and servicebull Program of internal radiation committed internal
radiation effective dose calculation by the stand-ard model
bull Background phantombull Personal computer and printer
Collimator with rotator and holder
SPC ldquoDozardquoRadiation monitoring equipment
70 71
bull Categorization of wastes for the purpose of fur-ther processing including wastes with unknown radionuclide composition
bull Measurements during the incoming waste inspec-tion (accepting for storage disposal)
bull Certification of unconditioned and conditioned wastes in closed containers without opening them (at nuclear plants or at facilities providing collection storage transportation conditioning processing temporal storage and final disposal of radioactive waste)
bull Activity measurement of extended objects in situ without opening the equipment
bull Activity measurement of extended objects after opening (for example assessment of tubes used for oil transportation)
MKG-01D ldquoSADOVNIKrdquoSPECTROMETRY SYSTEM
Physical charachteristicsDetectorbull Detector unit GEM (GMX) with HPGe detector and
multi-positioning cryostat CFG-PMOD4-7 with 7 litre Dewar
bull Dose rate probe BDMG-200
Energy range bull With GEM detector 004 divide 30 MeVbull With GMX detector 0005 divide 15 MeVbull Dose rate probe BDMG-200 ndash 005 divide 30 MeV
Measurement rangebull 110-7 divide 10 Svhbull Relative efficiency of detection (in photopeak) at
13325 MeV (Co-60) 10 divide 150
Electrical characteristicsPower supplybull 220 V 50 Hz
Interfacebull USB
Complete setBasic complete setbull Spectrometric detector unit GEM (GMX) with
HPGe detector and multi-positioning cryostat with 7 litre Dewar
bull Portable digital multichannel analyzer DigiDARTbull Dose rate probe BDMG-200bull Autonomous power supply unit with built-in
batterybull Industrial computer keyboardbull Laser range-finderbull Thermographic printerbull Web-camerabull Device equipped with stepper motor for position-
ing of the spectrometric detectorbull Calibration device with reference sources
(Am-241 Co-60 Ba-133 Eu-152) for energy calibration
bull Removable collimators with end capbull Measurement proceduresbull ldquoClasterrdquo software
bull Measurement of gross alpha activity of alpha-emitting radionuclides
bull Measurement of alpha-emitting radionuclides activity in thin-layer samples meeting alpha-spectrometry requirements
Physical characteristicsDetectorbull Silicon ion-implanted 450 mm2
bull Easy to decontaminate thin windowbull dead layer less than 015 μmbull Background count rate in the range 3 divide 9 MeVbull No more than 09 h-1cm-2 for 450 mm2 detector
Energy rangebull 2 divide 9 MeVbull Lower limit of measurement range (minimum
detectable activity) 01 Bqbull Background count rate no more than 100 counts
in 24 hours
Electrical characteristics Power supplybull 220 V 50 Hz
Interfacebull USB
Complete setBasic complete setbull Detector unit with vacuum measuring chamber
and vacuum control systembull Low noise vacuum pump (type 2FY-05B or
equivalent)bull Check sourcebull ldquoProgressrdquo softwarebull Vacuum tube
MKS-01A ldquoMULTIRAD-ASrdquoALPHA SPECTROMETER
SPC ldquoDozardquoRadiation monitoring equipment
72 73
UCRV-2AIRFLOW MONITOR
bull Monitor of the air flow through filter of centralized multichannel sampling system
bull Radiation monitoring system (RMS) integration for internal exposures determination
bull Volume and flow rate measurements of the air that have passed through a analytical filter
bull Bar-code for filter identificationbull Operation as either standalone unit or as a part of
the RMS
Physical characteristicsMeasurement range of air volume bull 001 divide 9999 m3
Operation temperature range bull minus 20 divide +50 ordmС
Electrical characteristicsPower supply bull 220 V 50 Hz
Interface bull RS-485
PVP-06PORTABLE AIR SAMPLER
Air Sampler PVP-06 is indispensable for monitoring the radiation situation where the concentration of radioactive aerosols in the air does not require a sta-tionary sampling equipment Sampling head PVP-06 provides easy change of filters and cartridges
Purposebull To monitor the concentration of radioactive aero-
sols in the air sites
Controlled aerosolsbull Alpha- and beta-active aerosolsbull Daughter products of decay of radon and thoronbull Iodine isotopes
Physical characteristicsTypes of filtersbull Aerosol AFA-RSP-20bull Iodine AFA SI-20
Flow rate bull 33∙10-4 ndash 233∙10-4 m3s (20 divide 140 l min)
Electrical characteristicsPower supply bull 220 V50 Hzbull The vehicle power supply 108 divide 145 Vbull Internal battery
Minimal working time on internal battery to recharge bull 8 hours
Power consumption (at a flow rate of 100 lmin) bull 40 VA
Environment characteristicsOperating temperature bull minus 10 divide +40 deg C
Maximum humidity bull 90
Pressure bull 860 to 1060 hPA
Noise generated by the pump bull lt 55 dBA at 1 m
Mechanical characteristicsDimensions weight bull 241 times 108 times 160 mm 28 kg
Case material bull Plastic
Complete setbull Air sampler PVP-06bull AC power adapterbull Filters AFA-RSP-20 - 100 pcsbull Packaging for filters - 40 pcsbull Casebull Operation manualbull Calibration certificate
Optional equimpient bull Kit for sampling sorption columns of activated
carbon Ř head of sorption columns with protective
covers Ř activated charcoal SKT-3 - 1 pkg (02 L) Ř charocoal samples SC-13 - 8 pcs
bull Car charger bull Tipod bull Shoulder strapbull Calibration stand bull Filters AFA SI-20 - 100 pcs
Consumablesbull Aerosol filters AFA RSP-20bull Iodine filters AFA SI-20
SPC ldquoDozardquoRadiation monitoring equipment
74 75
Calibration of gamma dose and dose rate meters
Calibration ofbull Ambient equivalent dose H(10) meters (Sv Svh)bull Personal equivalent dose Hp(10) meters (Sv Svh)bull Exposure dose X meters (R Rh)bull Two sources in irradiator bull Select source and collimator opening using
tumbler
UPG-P DESKTOP GAMMA BEAM IRRADIATOR
Physical characteristicsRange of reproduced dose rate bull 05 μSvh divide 10 mSvh (50 μRh divide 100 mRh)
Sources activities bull 6times106 6times108 Bq (02 20 mCi) Cs-137
Overall dimensions bull 1250times400times300 mm
Irradiator weight bull Not more than 37 kg
Calibration bench weight bull Not more than 15 kg
Reference standards IEC 60846 IEC 61526
Physical characteristicsDetectorbull Silicon
Measurement range EEC measurement bull Measurement range of radon EEC
10 divide 10bull106 Bqbullm-3
bull Measurement range of thoron EEC 05 divide 10bull104 Bqbullm-3
bull Air flow through the filter 100plusmn05 lmin
Concentration measurementbull Measurement range of radon-222 concentration
in air 10 divide 20bull106 cpsbull Measurement range of 216Po(ThA)
1bull10-3 divide 1bull102 cpsbull Air sampler flow rate
10plusmn02 lminbull Measurement range of radon-222 concentration
in water samples 6 divide 800 Bqbullkg-1
bull Measurement range of radon-222 flux from soil surface 20 divide 103 mBqsbullm2
bull Measurement range of radon-222 concentration with preliminary sampling of air using air sam-plers 20 divide 107 Bqbullm-3
bull Measurement range of radon-222 concentration in samples of soil air 103 divide 106 Bqbullm-3
Operation temperature range bull 1 divide 35 ordmC
Electrical characteristicsPower supply bull 80 VA
Mechanical characteristicsOverall dimensions weight bull 220times200times165 mm 36 kg
ldquoALPHARAD PLUSrdquoRADON THORON amp THEIR PROGENY MONITORbull Measurement of radon and thoron concentration
and effective equivalent concentration (EEC)bull In the airbull In the indoor air of residential public and industri-
al buildings and structuresbull Measurement of radon in drinking water sourcesbull Measurements of radon flux from the soil surface
at land plots allocated for construction of houses public buildings and industrial facilities
bull Measurements of radon concentration in soil air
Reference standards IEC 61577
SPC ldquoDozardquoRadiation monitoring equipment
76 77
UKPN-2M-D NEUTRON BEAM IRRADIATOR
Reference standards IEC 61005 61322
Calibration of neutron dose and dose rate meters
Calibration ofbull Ambient equivalent dose H(10) meters (Sv Svh)bull Personal equivalent dose Hp(10) meters (Sv Svh)bull Flux density of neutrons (cm-2∙s-1)bull Transfer container for temporary storage of
sources bull Red light signal of source working position
Physical carachteristicsRange of reproduced dose ratebull 20 divide 800 μSvh
Range of reproduced flux densitiesbull 10 divide 400 cm-2∙s-1
Type of a source in use bull Pu-Be
Activity of a source in usebull 24х1011 Bq (with density of 107 s-1)
Overall dimensions weight no morebull 3000x750x2000 mm 300 kg
Required room dimensionsbull not less than 7x3x3 m
Electrical characteristicsPower supply bull 220 V 50 Hz
Calibration of gamma dose and dose rate meters
Calibration ofbull Ambient equivalent dose H(10) meters (Sv Svh)bull Personal equivalent dose Hp(10) meters (Sv Svh)bull Exposure dose X meters (R Rh)bull Four sources in irradiator bull Select source and move to working position
return to storage position using special rodbull Transfer container for temporary storage of
sources bull Red light signal of source working position
UPGD-2M-DGAMMA BEAM IRRADIATOR
Physical characteristicsRange of reproduced dose rate bull 05 μSvh divide 50 mSvh (50 μRh divide 5 Rh)
Maximum activity of source bull 2times1011 Bq (50 Ci) Cs-137
Overall dimensionsbull Irradiator 800times500times500 mmbull Guide rails length 30 mbull Height 16 mbull Weight not more than 700 kgbull Required room dimensions not less than 7x3x3 m
Electrical characteristicsPower supply bull 220 V 50 Hz
UPGD-2M-D
Reference standards IEC 60846 IEC 61526 IEC 61066
SPC ldquoDozardquo
78 79
Contents
MEASURING UNITS
DBG-S11D wide range gamma area monitor 40
UDKS-100 gamma and X-ray area monitor 41
UDMN-100 neutron area monitor 41
ALARM UNITS
BAS-2 ldquoMICROrdquo external visual alarm 42
BZS-2 ldquoMicrordquo external audible alarm 42
Illuminated warning signs 43
ldquoImpulsrdquo external display unit 43
UIM-3D area monitor count rate meter 44
DKG-05D personal gamma dosimeter 46
DVS-02D gamma-neutron personal electronic dosimeter 47
DVGI-8D new pen-type personal ionization chamber dosimeters 48
DKG-02U ldquoARBITERrdquo wide range gamma-dosimeter 49
DKG-07D ldquoDROZDrdquo gamma-dosimeter 50
MKS-15D ldquoSNEGIRrdquo multi ndash purpose radiation survey meter 51
SRPS-05D gamma monitor 52
DOZA-TLD multipurpose TLD system 53
DKS-96 universal radiation survey meter 54
EXTERNAL PROBES ALPHA
Alpha BDZA-96 55
Alpha BDZA-96B 55
Alpha BDZA-96M 55
Alpha BDZA-96S 55
Alpha BDZA-96T 55
EXTERNAL PROBES BETA
Beta BDZB-96 56
Beta BDZB-99 56
Beta BDZB-96B 56
Beta BDZB-96S 56
EXTERNAL PROBES GAMMA
Gamma BDKS-96B 57
Gamma and beta BDKS-96S 57
Gamma BDMG-96 57
EXTERNAL PROBES GAMMA
Gamma-search BDVG-96 58
Gamma-search BDPG-96 58
ContentsRadiation monitoring systemldquoPELIKANrdquo Radiation monitoring system (RMS) 6
BDMG-101 high range gamma area monitor 10
DBG-S11D wide range gamma area monitor 11
BDRG-52 high range gamma area monitor for accident and post-accident conditions 12
UDGP-01 Liquid technological environments monitor 13
UDMN-100 neutron area monitor 14
UDKG-100 Wel Liquid gamma monitor 14
BOP-1M data processing and transmission unit 15
UDA-1AB particulate monitor 16
UDG-1B noble gas monitor 17
UDG-03D noble gas monitor 18
UDI-1B iodine monitor 19
UDGB-01 noble gasesH-3C-14 monitor 20
UDGP-01 steam generator leakage monitor 21
UPPVM air flow parameters monitor 22
ldquoIMPULSrdquo external display unit 23
BI-2 remote display amp alarm unit 24
BASBAS-1s external alarm 25
SKGAV stack monitor 26
RMS software 28
RMS workstation ndash operator console 29
Configurator software 29
RM RACK radiation monitoring rack 30
SRKS-01D criticality accident alarm system 32
ldquoATLANT-Mrdquo environmental radiation monitoring system 34
ldquoBREEZErdquo high-volume air sampler 35
ldquoGAMMA-SENSORrdquo gamma-survey system 36
Radiation monitoring equipmentAREA MONITOR ldquoFREGATrdquo 38
BPI-1D local display unit 39
80
Gamma-search BDPG-96M 58
Gamma BDKG-96 stainless steel casing for geologic applications well logging 59
EXTERNAL PROBES NEUTRON
Neutron BDMN-96 59
Neutron-search BDKN-96 59
RZB-05D Hand-foot-clothing monitor 60
RZBA-04-04M whole body contamination monitor 61
RZA-05D alpha hand-monitor 62
UMF-2000 low level alpha- beta- counter 63
DRK dose area product meter 64
ldquoPROGRESS-BETArdquo scintillation beta spectrometer 65
ldquoPROGRESS-GAMMArdquo scintillation gamma spectrometer 66
ldquoPROGRESS-G(P)rdquo portable scintillation gamma spectrometer 67
ldquoPROGRESS-ARrdquo alpha radiometer 68
ldquoPROGRESSrdquo whole body counter 69
MKG-01D ldquoSADOVNIKrdquo spectrometry system 70
MKS-01A ldquoMULTIRAD-ASrdquo alpha spectrometer 71
UCRV-2 airflow monitor 72
PVP-06 portable air sampler 73
ldquoALPHARAD PLUSrdquo radon thoron amp their progeny monitor 74
UPG-P desktop gamma beam irradiator 75
UPGD-2M-D gamma beam irradiator 76
UKPN-2M-D neutron beam irradiator 77
Radiation monitoring system SPC ldquoDozardquo
16 17
UDG-1B NOBLE GAS MONITOR
Continuous automatic monitoring of the beta-emit-ting radioactive gases concentration in the working air and in the air in ventilation ducts and stacksbull Gamma background compensation bull Audible and visual alarm signals of the excess of
preset thresholds bull Periodic calibration by means of standard beta-
source
Physical characteristicsbull Silicon detectors (2 pcs for measurement and for
background compensation)bull Air flow rate 10 divide 100 lminbull Operation temperature range minus 10 divide +50 ordmС
Measurement range bull 104 divide 6109 Bqm3
Energy range bull 008 divide 30 MeV
Electrical characteristicsbull Power supply 85 divide 260 V 47 divide 440 Hzbull Interfaces RS-232 2timesRS-485 Ethernetbull programmable relay output (SPDT relay)bull Analog output 4-20 mA (optional)
Mechanical characteristicsbull Protection index IP 65bull Paint decontaminable
Overall dimensions weight bull Stationary version 395times240times304 mm 295 kgbull Mobile version with pump unit BN-1
395times468times950 mm 543 kg
Alarmbull Sound alarm 80 divide 100 dBA at distance 1 mbull Visual alarm green yellow red
Mobile version with pump unit BN-1
Stationary version
Reference standards Nuclear IEC 60761 IEC 62302 EMC IEC 61010 IEC 61000-6-2 Seismic IEC 60980
bull Connection of the external alarm unit ldquoBASrdquo type
Versionsbull Stationary versionbull Stationary version with pump unit BN-1bull Mobile version with pump unit BN-1
UDA-1AB PARTICULATE MONITOR
Stationary version
Continuous automatic monitoring of the alpha- and beta- radioactive aerosol concentration in the work-ing air and in the air in ventilation ducts and stacksbull Radon toron progenies and gamma background
compensation bull On line alpha spectrometrybull Audible and visual alarm signals of the excess of
preset thresholds bull Control of electromagnetic valves when operating
with the external air sampling linebull Control of pump unit bull Periodic calibration by means of standard beta-
and alpha-sources
Physical characteristicsbull Silicon specrometric detectors (2 pcs for measure-
ment and for background compensation)bull Filter tape types LFAS FSLWbull Tape consumption (when continuous operation)
10 m50 daysbull Air flow rate 10 divide 100 lmin bull Operation temperature range minus 10 divide +50 ordmС
Measurement range bull Alpha 10-2 divide 2105 Bqm3 bull Beta 10-1 divide 106 Bqm3
Energy range bull Alpha 30 divide 90 MeV bull Beta 005 divide 30 MeV
Electrical characteristicsbull Power supply 85 divide 260 V 47 divide 440 Hzbull Interfaces RS-232 2timesRS-485 Ethernet bull Programmable relay output (SPDT relay)bull Analog output 4-20 mA (optional)
Mechanical characteristicsbull Protection index IP 65bull Paint decontaminable
Overall dimensions weight bull Stationary version 389times260times304 mm 156 kg bull Mobile version with pump unit BN-1
389times468times950 mm 384 kg
Alarmbull Sound alarm 80 divide 100 dBA at distance 1 mbull Visual alarm green yellow redbull Connection of the external alarm unit ldquoBASrdquo type
Versionsbull Stationary versionbull Stationary version with pump unit BN-1bull Mobile version with pump unit BN-1
Reference standards Nuclear IEC 60761 IEC 61172 EMC IEC 61010 IEC 61000-6-2 Seismic IEC 60980
Mobile version with pump unit BN-1
Radiation monitoring system SPC ldquoDozardquo
18 19
Physical characteristicsbull Scintillation detectors CsI(Tl) (2 pcs for measure-
ment and for background compensation)bull Cartridge activated charcoal
Measurement range bull 37 divide 37106 Bqm3
Energy range bull 006 divide 30 MeVbull Air flow rate 20 divide 40 lminbull Operation temperature range minus 10 divide +50 ordmС
Electrical characteristicsbull Power supply 85 divide 260 V 47 divide 440 Hzbull Interfaces RS-232 2timesRS-485 Ethernetbull Programmable relay output (SPDT relay)bull Analog output 4-20 mA (optional)
Mechanical characteristicsbull Protection index IP 65bull Paint decontaminable
Overall dimensions weight bull Stationary version 448times323times479 mm 35 kgbull Mobile version with pump unit BN-1
448times468times950 mm 578 kg
Reference standards Nuclear IEC 60761 IEC 61171 EMC IEC 61010 IEC 61000-6-2 Seismic IEC 60980
Alarmbull Sound alarm 80 divide 100 dBA at distance 1 mbull Visual alarm green yellow redbull Connection of the external alarm unit of ldquoBASrdquo
type
Versionsbull Stationary versionbull Stationary version with pump unit BN-1bull Mobile version with pump unit BN-1
Сontinuous automatic monitoring radioiodine concentration in the air at working places and in ventilation ducts and stacksbull Measurement of volumetric activity of radionu-
clides I-131 I-132 I-133 I-135 in the airbull On line gamma spectrometrybull Gamma background compensation bull Performance self-test by means of Am-241 check
source implanted into the detectorbull Audible and visual alarm signals of the excess of
preset thresholdsbull Periodic calibration by means of standard source
UDI-1B IODINE MONITOR
Physical characteristicsbull Silicon detector 2 pcs (for measurement and for
background rejection)bull Air flow rate 10 divide 100 lminbull Operation temperature range minus 10 divide +50 ordmС
Measurement range bull 104 divide 11010 Bqm3
Energy rangebull 006 divide 30 MeV
Electrical characteristicsbull Power supply 120 Vbull Interface RS-485
Mechanical characteristicsbull Protection index IP 65bull Paint decontaminable
Overall dimensions weight bull 474х246х243 mm 295 kg
UDG-03D NOBLE GAS MONITOR
Measurement of volumetric activity of beta-emitting radioactive gases (argon krypton xenon) adapted to the measurement of the rapidly changing volume activity in various technological processesbull Gamma background compensationbull Periodic calibration by means of standard beta-
source
Reference standards Nuclear IEC 60761 IEC 62302 EMC IEC 61010 IEC 61000-6-2 Seismic IEC 60980
Radiation monitoring system SPC ldquoDozardquo
20 21
Continuous automatic monitoring of steam genera-tor primary to secondary leakagebull On line gamma spectrometrybull N-16 monitoringbull Performance self-test by means of Am-241 check
source implanted into the detectorbull Audible and visual alarm signals of the excess of
preset thresholds
Physical characteristics
UDGP-01 STEAM GENERATOR LEAKAGE MONITOR
bull detector ndash scintillator CsI Oslash 40х100 mm
Measurement range bull High energy gamma-activity (N-16)
15bull103 divide 20bull108 Bqm3
bull General gamma-activity 10bull104 divide 20bull108 Bqm3
Energy range bull General gamma 005 divide 15 MeV bull in integral spectral band of energy
5000 divide 7200 keV bull temperature range minus 10 divide +80 ordmС
BOP-1SP
Electrical characteristicsbull Power supply 85 divide 260 V 47 divide 440 Hzbull Interfaces RS-232 RS-485 Ethernetbull programmable relay output (SPDT relay)
Mechanical characteristicsbull Protection index IP 65bull Paint decontaminable
Overall dimensions weight bull Detector unit Oslash 60x360 mm17 kgbull Data processing and transmission unit BOP-1sp
280x220x114mm 43 kgbull Collimator Oslash 350x455 mm 150 kg
Alarmbull Sound alarm 80 divide 100 dBA at distance 1 mbull Visual alarm green yellow redbull Connection of the external alarm unit of ldquoBASrdquo
type
Reference standards Nuclear IEC 61453 EMC IEC 61010 IEC 61000-6-2 Seismic IEC 60980Reference standards Nuclear IEC 60761 IEC 60710 IEC 60951-2 EMC IEC 61010 IEC 61000-6-2 Seismic IEC 60980
Ionization chambe 10 liters
UDGB-01T1
Physical characteristicsbull Detectors - stainless steel ionization chambersbull Air flow rate 10 divide 100 lminbull Operation temperature range minus 10 divide +50 ordmС
Volumes of ionization chambers bull UDGB-01T UDGB - 01T1 100 litersbull UDGB-01T2 01 liter
Measurement range (Kr-85) bull UDGB-01T UDGB-01T1 10104 divide 50109 Bqm3
bull UDGB-01T2 109 divide 501014 Bqm3
Measurement range (H-3) bull UDGB-01T UDGB-01T1 50104 divide 50109 Bqm3
bull UDGB-01T2 50109 divide 501014 Bqm3
Electrical characteristicsbull Power supply 85 divide 260 V 47 divide 440 Hzbull Interfaces RS-232 2timesRS-485 Ethernetbull Programmable relay output (SPDT relay)bull Analog output 4-20 mA (optional)
Mechanical characteristicsbull Protection index IP 23bull Paint decontaminable
Continuous automatic monitoring of the beta-emitting radioactive gases including tritium and carbon-14 concentration in the air at working places and in ventilation ducts and stacksbull Audible and visual alarm signals of the excess of
preset thresholds bull Monitoring of the noble gase activity in gaseous
effluents and ventilation air for accident and post-accident conditions
Overall dimensions weight bull UDGB-01T 381times343times716 mm 30 kgbull UDGB-01T1 260times320times175 mm 125 kgbull Ionization chamber 100 liters Oslash 250times600 mm
6 kgbull UDGB - 01T2 381times343times716 mm 27 kg
Alarmbull Sound alarm 80 divide 100 dBA at distance 1 mbull Visual alarm green yellow redbull Connection of the external alarm unit ldquoBASrdquo type
Versionsbull UDGB-01T - with built-in ionization chamber
100 litersbull UDGB-01T2 - with built-in ionization chamber
01 literbull UDGB-01T1 - with remote ionization chamber
100 liters
UDGB-01NOBLE GASESH-3C-14 MONITOR
Radiation monitoring system SPC ldquoDozardquo
22 23
Physical characteristicsLength of communication cablebull up to 1200 m
Character height bull ldquoImpuls-910-Rrdquo 100 mmbull ldquoImpuls-915-D4Srdquo 150 mmbull ldquoImpuls-927-D4Srdquo 270 mm
Operating temperature rangebull ldquoImpuls-910-Rrdquo 0 divide +50 ordmCbull ldquoImpuls-915-D4Srdquo ldquo-927-D4Srdquo minus 40 divide +50 ordmC
Electrical characteristicsbull Power supply 220 V 50 Hz
Mechanical characteristicsProtection index bull ldquoImpuls-910-R IP 44bull ldquoImpuls -915-D4Srdquo ldquo-927-D4Srdquo IP 65
Overall dimensions weight bull ldquoImpuls-910-Rrdquo 400times160times60 mm 3 kgbull ldquoImpuls -915-D4Srdquo 815times250times80 mm 5 kgbull ldquoImpuls -927-D4Srdquo 1250times330times80 mm 5 kg
ldquoIMPULSrdquoEXTERNAL DISPLAY UNIT
Display of data received from monitors of RMS
External display unit ldquoImpuls-910-Rrdquo
Reference standards EMC IEC 61010 IEC 61000-6-2 Seismic IEC 60980
Continuous monitoring of the flow rate temperature and humidity of the gas flowbull Definition of air volume flow rate in stacks taking
into account temperature and humidity of the air
UPPVM AIR FLOW PARAMETERS MONITOR
Physical characteristicsMeasurement range bull air flow velocity 1 divide 20 msbull air temperature 0 divide +80 ordmСbull air humidity 10 divide 95
Electrical characteristicsbull Power supply 220 V 50 Hz bull Interfaces RS-232 Ethernet
Mechanical characteristicsProtection index bull BSPP-1st BSPP-1tv BOP-1s IP 65bull PP-st IPTV IP 54bull Paint decontaminable
Overall dimensions weight bull air velocity probe PP-st 60times38times136 mm 015 kgbull Interface block BSPP-1st 125times155times73 mm 07 kgbull air temperature and relative humidity probe
IPTV-056-A 333times100times60 mm 07 kgbull Interface block BSPP-1tv 125times155times73 mm 07 kgbull Data processing and transmission unit BOP-1s
280x233x111 mm 8 kg
Reference standards Nuclear ISO 2889 EMC IEC 61010 IEC 61000-6-2 Seismic IEC 60980
BOP-1S
Radiation monitoring system SPC ldquoDozardquo
24 25
BASBAS-1S EXTERNAL ALARM
Generation of audible and visual signals of the excess of preset thresholds RMS monitorsbull Audible alarm 80 divide 100 dBA at distance 1 mbull Visual alarm green yellow red
Distance from RMS monitorbull BAS up to 20 mbull BAS-1s up to 1200 m
Power supply bull 220 V 50 Hz
Overall dimensions weight bull BAS 145times108times460 mm 18 kg bull BAS-1s 166times109times466 mm 18 kg
Reference standards EMC IEC 61010 IEC 61000-6-2 Seismic IEC 60980
Physical characteristicsLength of communication cablebull up to 1200 m
Displayed page size bull 4 lines of 20 characters
Volume of loaded information bull 10 pages
Change of pagesbull programmed or by pressing a button
Operating temperature rangebull minus 40 divide +50 ordmC
Electrical characteristicsbull Power supply 9 divide 18 VDCbull Interfaces RS-485
Mechanical characteristicsbull Protection index IP 65bull Overall dimensions weight 222times164times73 mm
40 kg
BI-2 REMOTE DISPLAY amp ALARM UNIT
bull Display of data received from monitors of RMSbull Audible and visual alarms on exceeding preset
thresholds of the RMS equipment bull Individual threshold setting for each measure-
ment channelbull Audible alarm 80 divide 100 dB at a distance of 1 m bull Visual alarm red yellow green
Reference standards EMC IEC 61010 IEC 61000-6-2 Seismic IEC 60980
Radiation monitoring system SPC ldquoDozardquo
2726
Electrical characteristicsbull Power supply 220 V 50 Hz bull Interfaces RS-232 RS-485 Ethernetbull programmable relay output (SPDT relay)
Alarmbull Sound alarm 80 divide 100 dBA at distance 1 mbull Visual alarm green yellow redbull Connection of the external alarm unit ldquoBASrdquo type
Related monitors and equipmentsbull UDA-1AB particulate monitorbull UDG-1B noble gas monitorbull UDI-1B iodine monitorbull UPPVM air flow parameters monitorbull Sampling and sample separation rack
Air flow parameters monitor rack
Reference standards Nuclear IEC 60761 IEC 61171 IEC 61172 IEC 62302 ISO 2889 EMC IEC 61010 IEC 61000-6-2 Seismic IEC 60980
Sampling and sample separation rack
Continuous monitoring of radioactivity in gaseous effluentsbull Automatic monitoring of the alpha- and beta-
radioactive aerosol noble gas and radioiodine concentrations in the air in ventilation ducts and stacks
bull Monitoring of the flow rate temperature and humidity of the gas flow
bull Separation of gaseous effluent into targeted fractions by means of a two-stage filter
bull Reversion of gas after analysis to the ventilation system
Physical characteristics
Particulate (UDA-1AB)bull Silicon specrometric detectors (2 pcs for measure-
ment and for gamma-background compensation) bull Filter tape types LFAS FSLWbull Tape consumption (when continuous operation)
10 m50 days
Measurement range bull Alpha 10-2 divide 2105 Bqm3 bull Beta 10-1 divide 106 Bqm3
Energy range bull Alpha 30 divide 90 MeV bull Beta 005 divide 30 MeV
Noble gas (UDG-1B)bull silicon detectors (2 pcs for measurement and for
gamma-background compensation)
Measurement range bull 104 divide 6109 Bqm3
Energy range bull 008 divide 30 MeV
Iodine (UDI-1B)bull scintillation detectors CsI(Tl) (2 pcs for measure-
ment and for background compensation)
SKGAV STACK MONITOR
Particulate noble gas and iodine monitors rack
Measurement range bull 37 divide 37105 Bqm3
Energy range bull 015 divide 30 MeV
Air flow parameters (UPPVM)Measurement range bull air flow velocity 1 divide 20 msbull air temperature 0 divide +80 ordmСbull air humidity 10 divide 95
Radiation monitoring system SPC ldquoDozardquo
28 29
CONFIGURATOR SOFTWAREMaintenance and set-up softwarebull Set-up and verify RMS monitorsbull Control testing adjustment and repair of RMS
monitorsbull Monitors measurement results archive receive
and View bull Communication through RS-232
RMS WORKSTATION ndash OPERATOR CONSOLEOrganization of interaction of the RMS Server and Monitors
Single monitor console includes vandal-proof key-board amp UPS
Reference standard IEC 61559-1 IEC 61559-2
RMS SOFTWAREData acquisition storing and visual representation RMS monitors measurement resultsbull Ethernet IEEE 8023 networkbull Clientserver architecturebull TCPIP protocolbull Oracle based Data Basebull Supremal by means InSat MasterSCADA
Radiation monitoring system SPC ldquoDozardquo
30 31
Delivery setComposition and modification depend on the tasks to be solved using the RM Rack
The rack which is an integral part of RM Rack accommodatesbull Monitors UDA-1AB UDG-1B UDG-03D UDI-1B
UDGB-01Tbull DBG-S11D Wide range gamma area monitor
BDMG-101 High range gamma area monitor UDMN-100 Neutron area monitor BDRG-52R High range gamma area monitor
bull BI-2 Remote display amp alarm unitbull Pump unit BN-01bull Data processing and transmission unit BOP-1Mbull External alarm BAS or BAS-1sbull Equipment of sampling line (flow meters ball
valves filter holder piping solenoid valve)bull Switchboard (intended for switching of all equip-
ment and transfer of data to the upper level via the unified communication channel)
RM RACK RADIATION MONITORING RACK
The radiation monitoring rack (RM Rack) is designed for continuous monitoring of radiation parameters in premises and technological systems at nuclear facil-ities RM Rack can be used as a structural element of the lower-level of RMS at nuclear power plants and other nuclear facilities that involved in obtaining processing use and storage of radioactive materials
FeaturesContinuous automatic monitoring of the alpha- and beta- radioactive aerosol beta-emitting radioactive gases and radioiodine concentrations in the working air and in the air in stacks and others radiation parameters in the facilities
The stand providesbull Primary processing storage and transmission of
measured and related data into the information channel based on the Ethernet IEEE 8023 inter-face (TCPIP protocol)
bull Transfer of required data to the location where the equipment is installed via technological channels based on RS-232 interface
bull Generation of audible and visual warning alarm signals when the preset thresholds are exceeded
bull Display of received data on the LCD
Radiation monitoring system SPC ldquoDozardquo
32 33Reference standards IEC 60860 ANSIANS-83 ISO 7753
Purposebull Detection and recording of criticality accident
(CA) by measuring the absorbed dose rate of gamma-neutron radiation in the premises of monitored object its comparison with a threshold value and generation of audible and visual signals
bull Automatic collection processing storage and display of measurement data and related infor-mation as visual and graphical representation for operators of nuclear safety service
Functions of the systembull Detection and recording of CA events by con-
tinuous measurement of absorbed dose rate of gamma radiation comparison of measured values with preset thresholds generation of signals to activate the alarm
bull Activation of audible visual alarmbull In the event of CA turning on warning signals
ldquoDO NOT ENTERrdquo at illuminated information pan-els placed at the entrances to the controlled area
Featuresbull Data can be transferred to external data commu-
nication channel using RS-485 interface (DiBus data exchange protocol)
bull Automatic self-testing of detection units BR-04D with display of information about the type of fault
bull Possibility for connecting additional a detection and alarm units
bull Ability to function in general regardless of the functioning of components within the agreed scope of nuclear safety tasks
bull Radiation hardness up to 100 Gy
SRKS-01DCRITICALITY ACCIDENT ALARM SYSTEM
Features of softwarebull Collection of information via RS-485 network
displaying it on the PC monitor transmission to remote users archiving and storage
bull Status monitoring and display of values measured by BR-04D and DBG-S11D in locations as per layout of premises
bull Access to archived data with possibility to gener-ate reports for periods determined by operator
bull Maintenance and archiving of a log of dosimetric measurements data and events along with their time stamps
bull Possibility to transfer data to external users via Ethernet network for integrating of CA into higher level systems
Basic complete setLower level bull Control unit with power supplybull BR-04D detection unitsbull BZS-01D audible alarm unitsbull BSS-01D visual alarm unitsbull SIT-01D illuminated warning signsbull PBZ panels for muting audible alarmbull Network communication module
Additional lower layer devicesbull DBG-S11D wide range gamma area monitor
Upper layer bull CDP central display panelbull Service workstation
RS-485
RS-485
RS-4
85
Audible alarm units BZS-01D
Illuminated warning signs SIT-01D
Detection units BR-04D
Network communication
moduleDBG-S11D wide range gamma area monitor
Panels for muting audible alarm
Control unit with power supply
Visual alarm units BSS-01D
RS-485
RS-485
RS-4
85
Audible alarm units BZS-01D
Illuminated warning signs SIT-01D
Detection units BR-04D
Network communication
moduleDBG-S11D wide range gamma area monitor
Panels for muting audible alarm
Control unit with pow-er supply
Visual alarm units BSS-01D
RS-485
RS-4
85
Audible alarm units BZS-01D
Illuminated warning signs SIT-01D
Detection units BR-04D
Network communication
moduleDBG-S11D wide range gamma area monitor
Panels for muting audible alarm
Control unit with power supply
Visual alarm units BSS-01D
RS-485
RS-485
RS-4
85
Audible alarm units BZS-01D
Illuminated warning signs SIT-01D
Detection units BR-04D
Network communication
moduleDBG-S11D wide range gamma area monitor
Panels for muting audible alarm
Control unit with power supply
Visual alarm units BSS-01D
Ethernet
Central display panel Service workstation
RS-485
RS-485
RS-4
85
BZS-01D audible alarm units
SIT-01D illuminated warning signs
BR-04D detection units
Network communication
moduleDBG-S11D wide range gamma area monitor
PBZ panels for muting audible alarm
Control unit with power supply
BSS-01D visual alarm units
Radiation monitoring system SPC ldquoDozardquo
34 35
ldquoBREEZErdquoHIGH-VOLUME AIR SAMPLER
Physical characteristicsbull Measurement range of air flow rate
250 divide 1200 m3hbull Continuous operation time not less than 24 h
Filter materialsbull High-purity glass fiberbull Pure quartz or cellulosebull Filter fabric FPP-15-15
Electrical characteristicsPower supply bull 220380 V 50 Hz
Interfaces bull RS-485bull Ethernetbull GSMGPRS (option)
Environmental characteristicsTemperature range bull minus 40 divide + 40 ordmC
Relative humidity limit at 35 ordmC bull 95
Atmospheric pressure range bull 840 divide 1067 kPa
Versionsbull Standalone unit bull Part of Environmental Radiation Monitoring
System (ERMS)
Type of detection unitsbull Beta block BDZB-100Lbull DBG-S11D wide range gamma area monitorbull Scintillation spectrometric block
The motor of Air Sampler is controlled by an electronic flow sensor that detects changes in the operators pre-set flow rate caused by changes in temperature barometric pressure and pressure drop due to dust loading on filter media It compensates for these changes by adjusting the motor speed to maintain the pre-set flow ratebull Measurement of parameters of ionizing radiation bull Standalone mode of operation or as the part
of Environmental Radiation Monitoring System (ERMS)
Purposebull Environmental Radiation Monitoring System
(ERMS) in the control and buffer areas of the radia-tion and nuclear facilities
Referencesbull Since the year 2000 the system is successfully
operating the ERMSs at 8 Russian nuclear power plants (about 180 monitoring stations)
bull Since the year 2005 the ERMS is operating in the Moscow (about 40 monitoring stations)
bull Since the year 2005 the regional ERMS is under operation in several Russian Federation regions
Basic complete setMonitoring stations bull Data processing and transmission unit BOP-1TA bull Gamma area monitor DBG-S11D
Central data processing station (CDPS)bull Data processing and transmission unit BOP-1TAbull Server
By requestbull Emergency Response and Crisis Management
Centers for enterprisesbull Regional Emergency Response and Crisis Manage-
ment Centersbull rdquoBreezerdquo High-Volume Air Samplerbull Mobile lab with gamma-survey system rdquoGammandash
sensorrdquo
ldquoATLANT-MrdquoENVIRONMENTAL RADIATION MONITORING SYSTEM
Monitoring system for the continuous radiation monitoring of territories and facilities with the data transmission GSMGPRS network
Data transmission bull GSMGPRS
Power supply bull 220 V 50 Hz
Continuous autonomous operation (at 20 ordmC)bull From built-in battery not less than 5 hoursbull From external battery not less than 24 hours
Operation temperature bull Minus 40 divide +50 ordmC
Operation humidity bull Up to 98
Protection bull IP65
Reference standards Nuclear IEC 61017-11991 IEC 61017-21994
36
Radiation Monitoring Equipment
bull Localization of radioactive contaminationsbull Database with dose rate contaminations
spectra measurement date amp time coordi-nates
bull Work as part of mobile laboratory or as part of Environmental Radiation Monitoring System with real-time data transfer
Physical characteristicsDetector bull Scintillation NaI (Tl) GM counters
Measurement rangebull 01 ndash 107 μSvh
Energy range bull 005 ndash 3 MeV
Operation temperature range bull minus 10 divide +50 ordmС
Electrical characteristics bull Power supply 220 V 50 Hz
ldquoGAMMAndashSENSORrdquoGAMMA-SURVEY SYSTEM
SPC ldquoDozardquoRadiation monitoring equipment
38 39
AREA MONITOR ldquoFREGATrdquoArea Monitor ldquoFregatrdquo is designed for building rela-tively simple and inexpensive radiation monitoring systems at such facilities as radionuclide sources storage areas isotope products warehouses nuclear medicine departments PET centers calibration laboratories where sources of ionizing radiation are used etc
Small scale automated radiation monitoring systems built with ldquoFregatrdquo components featuring audible and visual alarms are matched suitable to meet the regulatory radiation safety requirements
Area monitor ldquoFregatrdquo requires virtually no adjust-ment it is simple and convenient for installation and operation
BPI-1D LOCAL DISPLAY UNIT
Display of monitored parameters values received from external measuring devices
Purposebull Processing and display of values of monitored
parameters on information panel bull Comparison of values of monitored parameters
with thresholdsbull Transfer of monitored parametersrsquo values to
networkbull Generation of alarm in case of exceeding of preset
thresholds including external alarm devices
FeaturesTesting the unit and connected devicesbull Visually on the panelbull Using adjustment software when connected to
PC via USB
Automatic self-testing
The panel displays the following informationbull Diagnostic information about the status of con-
nected devicesbull Current date and timebull Values of measured parametersbull Position of measured values with respect to the
thresholds in the form of scales with green yellow and red zones
bull Time history (trend) for each measured value
Physical characteristicsTemperature range bull minus 10 divide + 50 ordmC
Maximum number of connected devicesbull measuring devices 15bull external audible and visual alarm 15
Display diagonal bull 152 cm (6)
Electrical characteristicsbull Interfaces RS-485bull Power supply 220 V 50 Hz 12 divide 24 V
Mechanical characteristicsbull Protection index IP54bull Paint decontaminable
Overall dimensions weightbull 296x248x118 mm 5 kg
DBG-S11D wide range gamma area monitor
UDMN-100 neutron area monitor
Ethernet RS-485
UDKS-100 gamma and X-ray area monitor
BPI-1D Local display unit
BAS-2 ldquoMicrordquo external visual alarm
BZS-2 ldquoMicrordquo external audible alarm
ldquoImpulsrdquo external display unit
Service workstation
Illuminated warning signs
SPC ldquoDozardquoRadiation monitoring equipment
4140
Continuous automatic monitoring of the gamma- X-ray ambient dose equivalent rate
Physical characteristicsbull Detector tissue-equivalent plastic scintillator
Oslash 45times20 mm
Measurement range bull Dose rate measurement range 01 μSvh divide 1 Svh bull Energy range 0015 divide 10 MeV
Mechanical characteristicsbull Protection index IP65bull Paint decontaminable
Overall dimensions weightbull Oslash72times265 mm 15 kg
UDKS-100 GAMMA AND X-RAY AREA MONITOR
UDMN-100 NEUTRON AREA MONITOR
Physical characteristicsbull detector ndash scintillator ZnS(Ag) Li-6
Measurement range bull 01 μSvh divide 01 Svh
Energy range bull 0025 eV divide 100 MeV
Temperature range bull minus 45 divide +50 ordmC
Electrical characteristicsbull Interfaces RS-485
Mechanical characteristicsbull Protection index IP 65bull Paint decontaminable
Overall dimensions weight bull 428times258times347 mm 115 kg
Continuous automatic monitoring of the neutron-radiations ambient dose equivalent ratebull Spherical polyethylene moderator Oslash 239 mm
MEASURING UNITS
DBG-S11D WIDE RANGE GAMMA AREA MONITOR
Continuous automatic monitoring of the gamma- ambient dose equivalent rate
Physical characteristicsbull Detector ndash GM counters
Measurement rangebull DBG-S11D 01 μSvh divide 10 mSvhbull DBG-S11D-01 01 μSvh divide 10 Svhbull DBG-S11D-02 01 μSvh divide 100 Svh
Energy rangebull 005 divide 30 MeV
Temperature range bull minus 40 divide +50 ordmC
Electrical characteristicsbull Interfaces RS-485 USB
Mechanical characteristicsbull Protection index IP 68bull Paint decontaminable
Overall dimensions weightbull DBG-S11D Oslash 68times141 mm 065 kg bull DBG-S11D-01 Oslash 68times179 mm 07 kgbull DBG-S11D-02 Oslash 68times179 mm 07 kg
Versionsbull DBG-S11Dbull DBG-S11D-01bull DBG-S11D-02
Reference standards Nuclear IEC 60846 IEC 60532 EMC IEC 61010 IEC 61000-6-2 Seismic IEC 60980
SPC ldquoDozardquoRadiation monitoring equipment
4342
ALARM UNITS
Generation visual signals of the excess of preset thresholds
Physical characteristicsLength of communication cablebull up to 1200 mbull Alarm Visual alarm green yellow red
Electrical characteristicsbull Power supply +12 V
Mechanical characteristicsbull Protection index IP 23
Overall dimensions weight 160times84times41 mm 02 kg
BAS-2 ldquoMICROrdquo EXTERNAL VISUAL ALARM
Generation audible signals of the excess of preset thresholds
Physical characteristicsLength of communication cablebull up to 1200 mbull Audible alarm 80 divide 100 dB at a distance of 1 m
Electrical characteristicsbull Power supply +12 V
Mechanical characteristicsbull Protection index IP 23
Overall dimensions weight 160times84times41 mm 02 kg
BZS-2 ldquoMICROrdquo EXTERNAL AUDIBLE ALARM
Physical characteristicsLength of communication cablebull up to 1200 m
Electrical characteristicsbull Power supply 220 V 50 Hz
Mechanical characteristicsbull Protection index IP 23
Overall dimensions weight bull 330times110times20 mm 05 kg
Physical characteristicsLength of communication cablebull up to 1200 m
Character height bull ldquoImpuls-910-Rrdquo 100 mmbull ldquoImpuls-915-D4Srdquo 150 mmbull ldquoImpuls-927-D4Srdquo 270 mm
Operating temperature rangebull ldquoImpuls-910-Rrdquo 0 divide +50 degCbull ldquoImpuls-915-D4Srdquo ldquo-727-D4Srdquo minus 40 divide +50 degC
Electrical characteristicsbull Power supply 220 V 50 Hz
Mechanical characteristicsProtection index bull ldquoImpuls-910-R IP 44bull ldquoImpuls-915-D4Srdquo ldquo-727-D4Srdquo IP 65
Overall dimensions weight bull ldquoImpuls-910-Rrdquo 400times160times60 mm 3 kgbull ldquoImpuls-915-D4Srdquo 815times250times80 mm 5 kgbull ldquoImpuls-927-D4Srdquo 1250times330times80 mm 5 kg
ILLUMINATED WARNING SIGNS
ldquoIMPULSrdquo EXTERNAL DISPLAY UNIT
SPC ldquoDozardquoRadiation monitoring equipment
4544
Individual threshold setting for each measurement channel
Continuous area and process monitoring
Collect amp display data from two measurement chan-nels (units with RS-485 or analog pulses)
Audible and visual alarms on exceeding preset thresholds or status of connected devices
Individual threshold setting for each measurement channel
Switching on the external alarm or executive devices when any threshold is exceeded
The wide panel displays the following information bull Values of measured parameters as min-1∙cm-2
s-1∙cm-2 μSvhbull Diagnostic information about the status of con-
nected devicesbull Current date and timebull Position of measured values with respect to the
thresholds in the form of scales with green yellow and red zones
bull Time history (trend) for each measured value
Physical characteristics Measurement range bull Count rate up to 107 CPM (170 kHz)
Operating temperature range bull minus 20 divide +50 ordmC
Electrical characteristics bull Power supply 220 V bull Interfaces USB
Mechanical characteristics bull Protection index IP 65 bull Overall dimensions weight 222times164times73 mm
40 kg
UIM-3D AREA MONITOR COUNT RATE METER
Measurement of alpha radiation flux density
Detector unit BDZA-100 (70 cm2) Measurement range 01 divide 104 min-1∙cm-2
Detector unit BDZA-100B (300 cm2) Measurement range 01 divide 2103 min-1∙cm-2
Measurement of beta radiation flux density
Detector unit BDZB-100 (28 cm2) Measurement range 10 divide 105 min-1∙cm-2
Detector unit BDZB-100L (30 cm2) Measurement range 10 divide 104 min-1∙cm-2
Detector unit BDZB-11D (84 cm2) Measurement range 5 divide 15∙104 min-1∙m-2
OPTIONAL PROBESMeasurement of gamma radiation flux density
Detector units BDEG-03 Measurement range 4 divide 2000 s-1∙cm-2
Detector unit UDKG-100 for operation in the rocks ore liquid media and sludge Measurement range 40 divide 8000 s-1∙cm-2
Measurement of the ambient dose equivalent rate
Detector unit DBG-S11D Measurement range 01 μSvh divide 100 Svh
Measurement of neutron radiation ambient dose equivalent rate
Detector unit BDMN-100 Measurement range 01 μSvh divide 01 Svh
SPC ldquoDozardquoRadiation monitoring equipment
46 47Reference standards Nuclear IEC 61526
Measurement of gamma-radiation personal dose equivalent Hp(10)bull Stand-alone dosimeter or composed of dosimetric
system onebull Audible and visual alarmbull Large memory dose accumulation historiesbull Exclusion of unauthorized intervention in dosim-
etry operation
DKG-05D PERSONAL GAMMA DOSIMETER
Physical characteristicsDetectors bull Silicon
Measurement range bull Dose rate 1 μSvh divide 10 Svhbull Dose 01 μSv divide 15 Sv
Energy range bull 005 divide 30 MeV
Electrical characteristicsbull Power supply rechargeable NiMH battery 1
alcaline battery (type AAA)
Operation timebull Till recharging not less 400 hoursbull With one set batteries not less 1000 hours
Mechanical characteristicsOverall dimensions weight bull 47times26times87 mm (with clip) 70 g
Environmental characteristicsbull IP65bull Temperature range minus 20 divide +45 ordmCbull Humidity up to 98 at 35 ordmCbull Shock vibration and drop resistant
Alarmbull Excess of alarm thresholdsbull Warnings of self-test failure and battery discharge bull Audible alarm 80 dB at 40 cmbull Visual alarm blinking LED
Relative equipmentbull One dosimeter charger ZU-1Mbull Chargestorage cassetes KZU-28KZU-56bull ldquoSmart chargingrdquo feature extends battery life timebull DKG-05D reader US-05bull DKG-05D system reader DVS-01D
Reader-PC interfacebull US-05 USB bull DVS-01D Ethernet
KZU-28
Physical characteristicsDetectors bull Silicon Li-6
Gamma measurement range bull Dose rate 1 μSvh divide 10 Svhbull Dose 01 μSv divide 15 Sv
Gamma energy range bull 005 divide 60 MeV
Neutron measurement range bull Dose rate 1 μSvh divide 2 Svhbull Dose 20 μSv divide 15 Sv
Neutron energy range bull 0025 eV divide 20 MeV
Electrical characteristicsPower supply bull Rechargeable NiMH batterybull Operatiion time till recharging not less 200 hours
Mechanical characteristicsOverall dimensions weight bull 47times26times87 mm (with clip) 70 g
Environmental characteristicsbull IP65bull Temperature range minus 20 divide +40 ordmCbull Humidity up to 75 at 30 ordmCbull Shock vibration and drop resistant
Alarmbull Excess of alarm thresholds bull Warnings of self-test failure and battery discharge bull Audible alarm 80 dB at 40 cmbull Visual alarm blinking LED
Relative equipmentbull One dosimeter charger ZU-1Mbull Chargestorage cassetes KZU-28 KZU-56bull ldquoSmart chargingrdquo feature extends battery life timebull DVS-02D reader UZS-01Sbull DVS-02D system reader DVS-01D
Reader-PC interfacebull UZS-01S USB bull DVS-01D Ethernet
UZS-01DReference standards Nuclear IEC 61526
DVS-02D GAMMA-NEUTRON PERSONAL ELECTRONIC DOSIMETER
Measurement of gamma- and neutron radiations personal dose equivalent Hp(10)bull Stand-alone dosimeter or composed of dosimetric
system onebull Audible and visual alarmbull Large memory dose accumulation historiesbull Exclusion of unauthorized intervention in dosim-
etry operationbull Both albedo thermal neutrons and intermediate
fast neutrons registrationbull Usable in the fields of Pu(Be) Po(Be) Cf and other
neutron sources as well as near nuclear reactors without neutron spectrum estimation
SPC ldquoDozardquoRadiation monitoring equipment
48 49
Dosimeters DVG-03D
DVGI-8D NEW PEN-TYPE PERSONAL IONIZATION CHAMBER DOSIMETERS
Measurement of personal dose equivalent Hp(10) of gamma and X-ray radiationbull Hp(10) of continuous and pulsed gamma and
X-ray radiation bull Electronic reader KSU-1bull Dosimeter DVG-03D with electronic ID bull Personal dose histories in the readerrsquos memorybull Readerrsquos connection with PC for database main-
tenance
Physical characteristicsDetector bull Ionization chamber
Measurement range bull 001 mSv divide 25 mSv
Energy range bull 0015 divide 25 MeV
Temperature range bull Reader KSU-1 +10 divide +50 ordmСbull Dosimeter DVG-03D minus 40 divide +50 ordmС
Electrical characteristicsPower supply bull Reader KSU-1 220 V 50 Hz built-in batteries bull Dosimeter DVG-03D four batteries CR 1025 bull Batteries life 3 yearsbull Readers interfaces RS-232USB 20
Mechanical characteristicsOverall dimensions weightbull Dosimeter DVG-03D Oslash 18times126 mm 005 kgbull Reader KSU-1 235times232times125 mm 28 kg
Reference standards Nuclear IEC 62387-1
DKG-02U ldquoARBITERrdquo WIDE RANGE GAMMA-DOSIMETER
Physical characteristicsDetectors bull GM counters
Measurement rangebull Dose-rate 01 μSvh divide 3 Svhbull Dose 1 μSv divide 100 Sv
Energy range bull 005 divide 3 MeV
Electrical characteristicsbull Power supply 2 alcaline batteries (type AA)bull Batteries life not less 200 hours
Mechanical characteristicsOverall dimensions weight bull 152times82times32 mm 03 kg
Environmental characteristicsbull Temperature range minus 20 divide +50 ordmCbull Humidity up to 90 at +25 ordmCbull Shock vibration and drop resistant
Reference standards Nuclear IEC 60846
Measurement of gamma radiation ambient equiva-lent dose H(10) and dose rate H(10)bull Audible signals (clicks) for radiation condition
estimationbull Analog scale for search modebull Audible and visual alarms of the excess of preset
dose and dose rate thresholds bull Shock-resistant water-proof easy decontamina-
tion casebull 100 measurement results memory with date and
time of measurementbull Indication of total dose accumulated during
exploitation time bull Indication of measurement result statistical
uncertainty
SPC ldquoDozardquoRadiation monitoring equipment
50 51
Physical characteristicsDetectors bull GM counter
Measurement rangebull Dose-rate 01 μSvh divide 3 mSvhbull Dose 1 μSv divide 02 Sv
Energy range bull 005 divide 3 MeV
Temperature range bull Minus 20 divide +50 ordmC
Electrical characteristicsbull Power supply 2 alcaline batteries 15 V (type AA)bull Batteries life not less 200 hours
Mechanical characteristicsOverall dimensions weight bull 122times74times29 mm 025 kg
Reference standards Nuclear IEC 60846
DKG-07D ldquoDROZDrdquoGAMMA-DOSIMETER
Measurement of gamma radiation ambient equiva-lent dose H(10) and dose rate H(10)bull Two independent measurement channels dose
and dose ratebull Audible signals (clicks) for radiation condition
estimationbull Continuous measurement with updating meas-
urement resultbull Measurement result can be obtained with any
desired statistical uncertainty (error)bull Automatic restart when radiation level sharply
changesbull Indication of statistical uncertainty (error) during
measurement process
Continuous measurement with updating measure-ment result
Automatic restart when radiation level sharply changes bull Gamma dose H(10) and dose-rate H(10) meas-
urementbull Beta and gamma contamination surveybull Indication of statistical uncertainty during the
measurementbull Continuous measurement with accuracy increas-
ing with time bull Automatic restart triggered by change of gamma
dose-ratebull Compensation of gamma count rate while meas-
uring beta radiationbull Indication of battery charge levelbull Audible signal of the excess of preset threshold
Physical characteristicsDetectors bull GM counter
Measurement range bull Dose-rate 01 microSvh divide 20 mSvhbull Dose 1 microSv divide 100 Svbull Beta flux density (for Sr-90+Y-90)
10 divide 105 cm-2 min-1
Energy range bull Gamma 005 divide 3 MeVbull Beta 01 divide 3 MeV
Temperature range bull Minus 20 divide +50 ordmC
MKS-15D ldquoSnegirrdquo backside
MKS-15D ldquoSNEGIRrdquoMULTI ndash PURPOSE RADIATION SURVEY METER
Reference standards Nuclear IEC 60846 IEC 60325
Electrical characteristicsbull Power supply 2 alcaline batteries (type AA)bull Battery life not less 400 hours
Mechanical characteristicsOverall dimensions weight bull 124times72times35 mm 035 kg
SPC ldquoDozardquoRadiation monitoring equipment
52 53
Physical characteristicsDetectorbull GM counter
Measurement range bull 01 μSvh divide 20 mSvh
Energy range bull 005 divide 30 MeV
Threshold setting range bull 03 μSvh divide 20 mSvh
Step change of the thresholdbull In the range 03 divide 10 μSvh with the step
001 μSvhbull In the range 10 divide 100 μSvh with the step
01 μSvhbull In the range 100 divide 2000 μSvh with the step
10 μSvh
Electrical characteristicsPower supply bull 220 V 50 Hz bull Relay output
Mechanical characteristicsProtection index bull IP 40
Overall dimensions weight bull 226times120times75 mm 07 kg
Alarmbull Sound alarm 80 divide 100 dBA at distance 1 mbull Visual alarm redbull Connection of the external alarm signaling unit
Reference standards Nuclear IEC 60846 IEC 60532
Continuous automatic monitoring of the ambient dose equivalent rate bull Measurement of gamma dose rate H(10)bull Audible and visual alarm signals for preset
thresholdsbull Switching on the external signaling or executive
devices
SRPS-05D GAMMA MONITOR
Measurement ofbull Gamma and X-ray personal dose equivalent
Hp(10)bull Neutron personal dose equivalent Hp(10)bull Lens dose equivalent Hp(3)bull Skin dose equivalent Hp(007)bull TLD reader day-to-day tests using built-in LEDbull No needs nitrogen for heating
Physical charachteristicsDetectors bull 7LiF Mg Ti (gamma beta)bull 6LiF Mg Ti (neutron)
Gamma and X-ray Hp(10) Measurement range bull 500 μSv divide 10 Sv
Energy range bull 0015 divide 30 MeV
Neutron Hp(10)Measurement range bull 01 mSv divide 100 mSv
Energy range bull 0025 eV divide 10 MeV
Beta and photons Hp(007) Hp(3) Measurement range bull 2 mSv divide 100 Sv
Energy range bull Beta 025 divide 35 MeVbull Photons lt15 keV
Mechanical characteristicsDosimeters overall dimensions weight bull Gamma Hp(10) DTL-2 holder - 62times26times16 mm
16 gbull DTU holder - 42times28times18 mm 8 gbull Lens Hp(3) face skin Hp(007) Oslash 32times16 mm 9 gbull Finger skin Hp(007) 90times20times2 mm 1 gbull Neutron gamma Hp(10) 48times40times20 mm 30 g
Reference standards Nuclear IEC 61066
DTL-2 DTU-2
MKD (A-type) DVNG-M
DOZA-TLD MULTIPURPOSE TLD SYSTEM
SPC ldquoDozardquoRadiation monitoring equipment
54 55
Continuous and pulsed gamma and X-ray dose H(10) and dose-rate measurementbull Alpha beta and gamma contamination surveybull Neutron dose H(10) and dose-rate measurementbull Gamma radiation flux density in boreholes and
liquid media measurement
Electrical characteristicsPower supply bull UIK-05 four C-size batteriesbull UIK-05-01 rechargeable batterybull UIK-06 rechargeable battery
Interfaces bull RS-232bull USB (via adapter)
bull Detector type automatic determination and corre-sponding measurement modes selection
bull Alarm threshold settings ndash for dose dose-rate alpha and beta contaminations
bull ldquoDetectrdquo and ldquoLocaterdquo modes for survey probes
Reference standards Nuclear IEC 60846 IEC 60325 IEC 61005 IEC 62363
Case
UIK-06 control unit165times78times48 mm 03 kg
DKS-96UNIVERSAL RADIATION SURVEY METER
UIK-05 control unit202times86times90 mm 10 kg
BDZA-96
BDZA-96B
BDZA-96M
BDZA-96S
BDZA-96T
EXTERNAL PROBES ALPHAALPHA BDZA-96Detector bull ZnS(Ag) 70 cm2
Measurement range (for Pu-239)bull 01 divide 104 min-1cm-2
Overall dimensions weightbull Oslash 130times240 mm 11 kg
ALPHA BDZA-96BDetector bull ZnS(Ag) 300 сm2
Measurement range (for Pu-239)bull 01 divide 2103 min-1cm-2
Overall dimensions weightbull Oslash 230times290 mm 40 kg
ALPHA BDZA-96MDetector bull ZnS(Ag) 10 сm2
Measurement range (for Pu-239)bull 01 divide 105 min-1cm-2
Overall dimensions weightbull Oslash 65times240 mm 09 kg
ALPHA BDZA-96SDetector bull ZnS(Ag) 30 сm2
Measurement range (for Pu-239)bull 01 divide 5104 min-1cm-2
Overall dimensions weightbull Oslash 90times240 mm 10 kg
ALPHA BDZA-96TDetector bull Silicon 5 сm2
Measurement range (for Pu-239)bull 01 divide 106 min-1cm-2
Overall dimensions weightbull Oslash 50times60 mm 015 kg
SPC ldquoDozardquoRadiation monitoring equipment
56 57
BETA BDZB-96Detector Scintillator 28 сm2
Measurement range (for Sr-90+Y-90)bull 10 divide 105 min-1cm-2
Energy rangebull 03 divide 30 MeV
Overall dimensions weightbull Oslash 90times230 mm 09 kg
BETA BDZB-99Detector bull GM counter 30 сm2
Measurement range (for Sr-90+Y-90)bull 20 divide 104 min-1см-2
Energy rangebull 012 divide 30 MeV
Overall dimensions weightbull Oslash 88times80 mm 04 kgbull Telescopic pole length 07 m
BETA BDZB-96BDetector bull GM counter 80 сm2
Measurement range (for Sr-90+Y-90)bull 3 divide 104 min-1сm-2
Energy rangebull 012 divide 30 MeV
Overall dimensions weightbull 150times200times110 mm 15 kg
BETA BDZB-96Sbull Detector GM counter 15 сm2
Measurement range (for Sr-90+Y-90)bull 10 divide 3104 min-1cm-2
Energy rangebull 012 divide 30 MeV
Overall dimensions weightbull Oslash 65times65 mm 03 kgbull Telescopic pole length 07 m
BDZB-96
BDZB-99
BDZB-96B
BDZB-96S
EXTERNAL PROBES BETA
GAMMA BDKS-96BDetector bull Tissue-equivalent scintillator Oslash 45times20 mm
Measurement rangebull Dose rate H(10) 01 μSvh divide 1 Svhbull Dose H(10) 01 μSv divide 10 Sv
Energy rangebull 0015 divide 10 MeV
Overall dimensions weightbull Oslash 60times250 mm 085 kg
GAMMA AND BETA BDKS-96SDetector bull Double GM counters
Measurement rangebull Gamma dose rate H(10) 01 μSvh divide 1 mSvhbull Gamma dose H(10) 01 μSv divide 10 Svbull Beta 10 divide 3104 min-1cm-2
Energy rangebull Gamma 005 divide 3 MeVbull Beta 012 divide 3 MeV
Overall dimensions weightbull Oslash 80times80 mm 035 kgbull Telescopic pole length 07 m
GAMMA BDMG-96Detector bull GM counters
Measurement rangebull Dose rate H(10) 01 μSvh divide 10 Svhbull Dose H(10) 01 μSv divide 10 Sv
Energy range bull 005 divide 3 MeV
Overall dimensions weightbull 40times250 mm 05 kgbull Telescopic pole length 07 m 4 m (by request)
EXTERNAL PROBES GAMMA
BDKS-96B
BDMG-96
BDKS-96S
SPC ldquoDozardquoRadiation monitoring equipment
58 59
GAMMA-SEARCH BDVG-96Detector bull Scintillator NaI(Tl) Oslash 63times63 mm
Measurement rangebull Flux density measurement range 4 divide 2000 s-1cm-2
bull Dose rate H(10) for Cs-137 01 divide 30 μSvhbull Sensitivity for Cs-137 3000 (pulsess-1)( μSvh-1)
Overall dimensions weightbull Oslash 88times400 mm 20 kgbull Modular pole length 16 m
GAMMA-SEARCH BDPG-96Detector bull Scintillator NaI(Tl) Oslash 25times40 mm
Measurement rangebull Flux density measurement range 10 divide 8000 s-1cm-2
bull Dose rate H(10) for Cs-137 01 divide 100 μSvhbull Sensitivity for Cs-137 500 (pulsess-1)( μSvh-1)
Overall dimensions weightbull 50times190times480 mm 10 kgbull Telescopic pole length 07 m
GAMMA-SEARCH BDPG-96MDetector bull Scintillator NaI(Tl) Oslash 18times30 mm
Measurement rangebull Flux density measurement range 10 divide 24000 s-1cm-2
bull Dose rate H(10) for Cs-137 01 divide 300 μSvhbull Sensitivity for Cs-137 200 (pulsess-1)( μSvh-1)
Overall dimensions weightbull Oslash 35times320 mm 05 kgbull Telescopic pole length 07 or 38 m
EXTERNAL PROBES GAMMA
BDVG-96
BDPG-96M
BDPG-96
EXTERNAL PROBESGAMMA BDKG-96 STAINLESS STEEL CASING FOR GEOLOGIC APPLICATIONS WELL LOGGINGDetector bull Scintillator NaI(Tl) Oslash 18times30 mm
Measurement rangebull Flux density measurement range 10 divide 105 s-1cm-2
bull Dose rate H(10) for Cs-137 5 divide 2104 μRhbull Sensitivity for Cs-137 200 (pulsess-1)( μSvh-1)
Overall dimensions weightbull Oslash 38times535 mm 36 kgbull Cable length 10 divide 1000 m
NEUTRON BDMN-96Detector bull Scintillator with ZnS(Ag)
Measurement rangebull Dose rate H(10) 01 μSvh divide 01 Svhbull Dose H(10) 01 μSv divide 10 Sv
Energy range bull 0025 eV divide 10 MeV
Overall dimensions weightbull Detector Oslash 54times200 mm 08 kgbull Moderator Oslash 245 mm 73 kg
NEUTRON-SEARCH BDKN-96Detector bull He-3 counter in polyethilene moderator
Measurement rangebull Dose rate H(10) for Pu-Be 01 μSvh divide 01 Svhbull Dose H(10) for Pu-Be 01 μSv divide 10 Sv
Energy range bull 0025 eV divide 14 MeV
Overall dimensions weightbull 295times142times100 mm 225 kg
BDKG-96M
BDMN-96
BDKN-96
SPC ldquoDozardquoRadiation monitoring equipment
60 61
bull No gas supply neededbull Clothing control detachable right hand detector bull Alpha detector optional connection bull Numeric and color (red green) indication of
control resultsbull LED sensor of hand-foot positioning for start of
measurementbull Automatic compensation of gamma background
and contamination of detectorbull Audible alarm signals of the excess of preset
thresholdsbull Measurement value indication min-1cm-2 or
Bqсm2
Reference standards Nuclear IEC 61098
RZB-05D HAND-FOOT-CLOTHING MONITOR
Physical characteristicsDetectors bull Gamma beta - GM countersbull Alpha - scintillatior ZnS(Ag)
Detecting nuclidesbull Alpha Pu-239 U-234 U-238bull Beta Sr-90+Y-90 F-18 Cs-137 Co-60 Tс-99 O-15
N-13 Sr-89 C-11 I-131 Na-22 Ru-106+Rh-106 Tl-204
bull Gamma Tc-99m I-123
Efficiencybull Alpha
Pu-239 40 U-234 25U-238 15
bull Beta Sr-90 +Y-90 40
Measurement range bull Alpha 1 divide 103 min-1cm-2 bull Beta 10 divide 103 min-1cm-2
bull Gamma 5103 divide 5106 min-1cm-2
Energy range bull Alpha 30 divide 80 MeV bull Beta 008 divide 35 MeV bull Gamma 005 divide 30 MeV
Operation temperature range bull Minus 10 divide +50 ordmС
Electrical characteristicsbull Power supply 220 V 50 Hz
Mechanical characteristicsOverall dimensions weight bull 740times750times1180 mm 45 kg
Versionsbull Withwithout alpha detectorbull Indication (min-1cm-2 ) or (Bqсm2)bull Detectors overall dimensions smbull Hand 178 х 235bull Foot 185 х 436
Whole body contamination monitor RZBA-04-04Mbull No gas supply neededbull Compensation for background gamma radiation
and contamination of detector unitsbull Individual threshold setting for each measure-
ment channelbull Visible and audible alarms ldquoCONTAMINATIONrdquo and
ldquoCLEANrdquo bull Indication of contaminated body parts on the
panel with image of the bodybull Optional remote alpha-detector
Physical characteristicsDetectors bull Beta - GM counters scintillatorsbull Alpha - scintillatior ZnS(Ag)
Measurement range bull Beta 5 divide 15000 min-1cm-2
bull Alpha 01 divide 10000 min-1cm-2
Energy range bull Beta 015 divide 25 MeV bull Alpha 40 divide 56 MeV
Operation temperature range bull +5 divide +50 ordmС
Electrical characteristicsPower supply bull 220 V 50 Hz
Interfaces bull RS-232bull RS-485
Mechanical characteristicsOverall dimensions weight bull 2650times940times930 mm 310 kg
Versionsbull Withwithout alpha detectorbull Indication (min-1cm-2 ) or (Bqсm2)
Reference standards Nuclear IEC 61098
RZBA-04-04MWHOLE BODY CONTAMINATION MONITOR
SPC ldquoDozardquoRadiation monitoring equipment
62 63
RZA-05DALPHA HAND-MONITOR
bull No gas supply needed bull Numeric and color (red green) indication of
control resultsbull LED sensor of hand- positioning for start of
measurementbull Audible alarm signals of the excess of preset
thresholdsbull Measurement value indication min-1cm-2 or
Bqсm2
Physical characteristicsDetectors alpha - scintillatior ZnS(Ag)
Efficiencybull Pu-239 20 bull U-234 14bull U-238 8
Measurement range bull 05 divide 105 min-1cm-2
Energy range bull 41 divide 90 MeV
Operation temperature range bull minus 10 divide +50 ordmС
Electrical characteristicsPower supply bull 220 V 50 Hz
Mechanical characteristicsOverall dimensions weight no more bull 740times1400times1450 mm 70 kg
Reference standards Nuclear IEC 61098
bull Simultaneous measurement of alphabeta activi-ties in the sample
bull Active shielding anti-coincidence background subtraction using GM counters
bull Lead shielding 30 mm
UMF-2000 LOW LEVEL ALPHA- BETA- COUNTER
Physical characteristicsDetectors bull Silicon specrometric detector 500 or 1000 mm2
Measurement range bull Alpha 001 divide 1000 Bq bull Beta 01 divide 3000 Bq
Energy range bull Alpha 35 divide 80 MeV bull Beta 005 divide 35 MeV
Electrical characteristicsPower supply bull 220 V 50 Hz
Interfaces bull RS-232bull USB
Mechanical characteristicsOverall dimensions weight bull 337times286times190 mm 22 kg
Versionsbull Detector area 500 mm2
bull Detector area 1000 mm2
UMF-2000 Detector area 1000 mm2
UMF-2000 Detector area 500 mm2
SpectraDec software for alpha-spectrometric measurements
SPC ldquoDozardquoRadiation monitoring equipment
64 65
DRK DOSE AREA PRODUCT METER
DRK-1bull Diagnostic reference level (DRL) of patients
determinationbull Suitable for all basic types of x-ray machines
Physical characteristicsDetector bull Plane-parallel ionization chamber
Measurement range bull 1 divide 104 cGycm2
Electrical characteristicsPower supply bull 220 V 50 Hz
DRK-1M-CTbull Measuring of dose length product
Physical characteristicsDetector bull Pencil Ionization Chamber
Measurement rangebull 05 divide 109 microGym
DRK-1Mbull Measuring of air kerma on sectional area of the
X-ray beam productbull Measuring of air kerma rate on area productbull Measuring of air kerma ratebull Measuring of air kerma
Physical characteristicsDetector bull Plane-parallel ionization chamber
Measurement rangebull 01 divide 109 microGym2
bull 06 divide 6104 microGym2cbull 30 divide 9105 microGycbull 30 divide 9991011 microGyReference standard IEC 60580 2003
bull Measurement of strontium-90 in the foodstuffs agricultural products etc
bull Measurement of gross beta activity in samplebull Self tests using built-in LED
ldquoPROGRESS-BETArdquo SCINTILLATION BETA SPECTROMETER
Physical characteristicsDetector bull Plastic scintillator Oslash70x10 mm
Sample bull Plate Oslash70 mmbull Weight up to 15 g
Energy range bull 02 divide 30 MeV
Minimum detectable activity of Sr-90 in a 10 g sample on a standard planchet Bqsamplebull In case of absence of K-40 in the sample 01 Bqbull In case the activity of K-40 till 5 Bqg 05 Bq
Electrical characteristics Interface bull USB
Mechanical characteristicsWeight bull No more 50 kg
Complete setBasic complete setbull Detector unit with plastic scintillator integrated
power supply amplifier ADC bull Lead shielding bull ldquoProgressrdquo software bull Сheck source for energetic calibration (Sr-90-Y-90) bull Planchet Oslash 70 mm (5 items) bull Sample dencification device bull Procedure manual for measurement of radio-
nuclidesrsquo activity using the scintillation beta spec-trometer ldquoProgressrdquo
Optional equipment and servicebull Personal computer and printer bull Calibrations for radionuclides not included in the
main library of radionuclides
Progress-Beta
Reference standards IEC 61562
SPC ldquoDozardquoRadiation monitoring equipment
66 67
bull Measurement of gamma activity in foodstuffs soil samples and others environmental objects
bull Identification of radionuclides in the sample bull Automatic correction for sample density bull Self-tests using built-in LED
ldquoPROGRESS-GAMMArdquoSCINTILLATION GAMMA SPECTROMETER
Physical characteristicsDetector bull NaI (Tl) Oslash63times63 mm
Validated measurement geometries bull Marinelli beakers (1 liter) Petri dishes (Oslash90 mm)
etc
Energy range bull 02 divide 30 MeV
Minimum detectable activity Bqsamplebull Cs-137 3 Bqbull Th-232 7 Bqbull Ra-226 8 Bq bull К-40 40 Bq
Electrical characteristics Interface bull USB
Mechanical characteristicsWeight bull No more 120 kg
Complete setBasic complete setbull Scintillation detector unit with NaI (Tl) detector
with integrated power supply amplifier and ADC bull Lead shielding 50 mm bull ldquoProgressrdquo software bull Сheck source for energy calibration (Cs-137 +
K-40)bull Marinelli beakers - 1 liter (5 items) bull Petri dishes Oslash 90 mm (5 items) bull Procedure manual for measurement of activity
of radionuclides using the scintillation gamma spectrometer ldquoProgressrdquo
Optional equipment and servicebull Kit for radon measurements including calibration
of ldquoIC-63rdquo geometry for counting the charcoal samples
bull Personal computer and printer bull Calibrations for user defined geometries bull Calibrations for radionuclides not included in the
main library of radionuclides
Progress-Gamma
Reference standards IEC 61563
ldquoPROGRESS-G(P)rdquoPORTABLE SCINTILLATION GAMMA SPECTROMETERbull Field measurements of gamma activity in environ-
mental objects without sampling (4π geometry)bull Laboratory measurement of gamma activity in
foodstuffs soil samples and others environmental objects
bull Identification of radionuclides in the sample bull Automatic correction for sample densitybull Tests using built-in LED
Physical charachteristicsDetector bull NaI (Tl) Oslash45times50 mmbull Lead shielding 20 mm
Validated measurement geometries bull Marinelli beakers (05 liter) Petri dishes (Oslash90 mm)
etc
Energy range bull 02 divide 30 MeV
Minimum detectable activity in 05-litre Marinelli beaker bull Cs-13710 Bqkgbull К-40100 Bqkgbull Ra-22618 Bqkg bull Th-23216 Bqkg
Minimum detectable activity in 30 min (4π geometry) bull Cs-137 2 Bqkgbull К-40 30 Bqkgbull Ra-226 4 Bqkg bull Th-232 3 Bqkg
Electrical characteristicsPower supply bull Rechargeable batterybull 220 V 50 Hz
Interface bull USB RS-232
Weight bull No more than 60 kg
Complete setBasic complete setbull Scinttillation detector unit with NaI(Tl) bull ldquoProgressrdquo softwarebull Сontrol unit ldquoSputnikrdquo for aquisition and analisys
of spectra with built-in memory for spectral databull Casebull Lead shielding (2 cm) for laboratory usebull 05-litre Marinelli beakers ndash 5 itemsbull Na-22 check sourcebull Power adapter BPS-01bull Operation manualbull Procedure manual for measurement of activity
of radionuclides using the scintillation gamma spectrometer ldquoProgressrdquo
Optional equipment and servicebull Kit for radon measurements with charcoalbull Built-in dose rate meterbull Additional memory (RAM) for storage of 64
spectrabull Additional power adapterbull Notebook and printer
Progress-Gamma
Reference standards IEC 61563
SPC ldquoDozardquoRadiation monitoring equipment
68 69
Physical characteristicsDetectorbull Scintillation detector ZnS (Oslash 60 mm)
Samplebull Thin sample - diameter up to 70 mm bull Preparation technique - electro-depositionbull Thick sample - diameter 70 mm weight
200300 mg bull Preparation technique - application of powders
(prepared by radiochemical concentration by water evaporation or by pounding of mineral samples) onto a planchet with the help of spirit
Energy rangebull 15 divide 8 MeV
Minimum detectable activitybull Thin samples no more than 910-3 Bqsamplebull Thick samples no more than 180 Bqkg
Mechanical characteristicsOverall dimensions weightbull 195times120times210 mm 34 kg
Complete setBasic complete setbull Alpha radiometer ldquoProgress-ARrdquobull Check source (uranium isotopes)
Set of accessoriesbull Procedure manual for measurements of radi-
oactivity using scintillation alpha radiometer ldquoProgress-ARrdquo
bull ldquoProgressrdquo software
ldquoProgress-ARrdquo
bull Measurement of gross activity of alpha emitting radionuclides in thin samples
bull Measurement of gross activity of alpha emitting radionuclides in thick samples
bull Measurement of activity deposited on aerosol filters
ldquoPROGRESS-ARrdquoALPHA RADIOMETER
Several fixed positions of the detector enable to perform measurements in various geometries and to estimate the content ofbull Cs-137 in the whole bodybull I-131 in thyroidbull Co-60 Cs-137 Mn-54 Cr-51 in lungsbull Database for storage of measurement data and
resultsbull Uncertainty calculations based on measurement
databull Self tests using built-in LED
ldquoPROGRESSrdquo WHOLE BODY COUNTER
Physical characteristicsDetectorbull scintillation detector NaI (Tl) Oslash63times63 mm
Energy rangebull 02 divide 28 MeV
Minimum detectable activitybull By Cs-137 in the whole body - 1200 Bqbull By I-131 in thyroid - 100 Bqbull By Co-60 Cs-137 Mn-54 Cr-51 in lungs - 200 Bq
Mechanical characteristicsWeight bull No more than 120 kg
Complete setBasic complete setbull Collimator with rotator and holderbull Detector with incorporated ADCbull Patient chair and table for collimatorbull Check source Na-22bull Procedure manual for lifetime measurement of
gamma-emitting radionuclidesrsquo activity in human body using the gamma-spectrometer of human radiation ldquoProgressrdquo
bull laquoProgressraquo software
Optional equipment and servicebull Program of internal radiation committed internal
radiation effective dose calculation by the stand-ard model
bull Background phantombull Personal computer and printer
Collimator with rotator and holder
SPC ldquoDozardquoRadiation monitoring equipment
70 71
bull Categorization of wastes for the purpose of fur-ther processing including wastes with unknown radionuclide composition
bull Measurements during the incoming waste inspec-tion (accepting for storage disposal)
bull Certification of unconditioned and conditioned wastes in closed containers without opening them (at nuclear plants or at facilities providing collection storage transportation conditioning processing temporal storage and final disposal of radioactive waste)
bull Activity measurement of extended objects in situ without opening the equipment
bull Activity measurement of extended objects after opening (for example assessment of tubes used for oil transportation)
MKG-01D ldquoSADOVNIKrdquoSPECTROMETRY SYSTEM
Physical charachteristicsDetectorbull Detector unit GEM (GMX) with HPGe detector and
multi-positioning cryostat CFG-PMOD4-7 with 7 litre Dewar
bull Dose rate probe BDMG-200
Energy range bull With GEM detector 004 divide 30 MeVbull With GMX detector 0005 divide 15 MeVbull Dose rate probe BDMG-200 ndash 005 divide 30 MeV
Measurement rangebull 110-7 divide 10 Svhbull Relative efficiency of detection (in photopeak) at
13325 MeV (Co-60) 10 divide 150
Electrical characteristicsPower supplybull 220 V 50 Hz
Interfacebull USB
Complete setBasic complete setbull Spectrometric detector unit GEM (GMX) with
HPGe detector and multi-positioning cryostat with 7 litre Dewar
bull Portable digital multichannel analyzer DigiDARTbull Dose rate probe BDMG-200bull Autonomous power supply unit with built-in
batterybull Industrial computer keyboardbull Laser range-finderbull Thermographic printerbull Web-camerabull Device equipped with stepper motor for position-
ing of the spectrometric detectorbull Calibration device with reference sources
(Am-241 Co-60 Ba-133 Eu-152) for energy calibration
bull Removable collimators with end capbull Measurement proceduresbull ldquoClasterrdquo software
bull Measurement of gross alpha activity of alpha-emitting radionuclides
bull Measurement of alpha-emitting radionuclides activity in thin-layer samples meeting alpha-spectrometry requirements
Physical characteristicsDetectorbull Silicon ion-implanted 450 mm2
bull Easy to decontaminate thin windowbull dead layer less than 015 μmbull Background count rate in the range 3 divide 9 MeVbull No more than 09 h-1cm-2 for 450 mm2 detector
Energy rangebull 2 divide 9 MeVbull Lower limit of measurement range (minimum
detectable activity) 01 Bqbull Background count rate no more than 100 counts
in 24 hours
Electrical characteristics Power supplybull 220 V 50 Hz
Interfacebull USB
Complete setBasic complete setbull Detector unit with vacuum measuring chamber
and vacuum control systembull Low noise vacuum pump (type 2FY-05B or
equivalent)bull Check sourcebull ldquoProgressrdquo softwarebull Vacuum tube
MKS-01A ldquoMULTIRAD-ASrdquoALPHA SPECTROMETER
SPC ldquoDozardquoRadiation monitoring equipment
72 73
UCRV-2AIRFLOW MONITOR
bull Monitor of the air flow through filter of centralized multichannel sampling system
bull Radiation monitoring system (RMS) integration for internal exposures determination
bull Volume and flow rate measurements of the air that have passed through a analytical filter
bull Bar-code for filter identificationbull Operation as either standalone unit or as a part of
the RMS
Physical characteristicsMeasurement range of air volume bull 001 divide 9999 m3
Operation temperature range bull minus 20 divide +50 ordmС
Electrical characteristicsPower supply bull 220 V 50 Hz
Interface bull RS-485
PVP-06PORTABLE AIR SAMPLER
Air Sampler PVP-06 is indispensable for monitoring the radiation situation where the concentration of radioactive aerosols in the air does not require a sta-tionary sampling equipment Sampling head PVP-06 provides easy change of filters and cartridges
Purposebull To monitor the concentration of radioactive aero-
sols in the air sites
Controlled aerosolsbull Alpha- and beta-active aerosolsbull Daughter products of decay of radon and thoronbull Iodine isotopes
Physical characteristicsTypes of filtersbull Aerosol AFA-RSP-20bull Iodine AFA SI-20
Flow rate bull 33∙10-4 ndash 233∙10-4 m3s (20 divide 140 l min)
Electrical characteristicsPower supply bull 220 V50 Hzbull The vehicle power supply 108 divide 145 Vbull Internal battery
Minimal working time on internal battery to recharge bull 8 hours
Power consumption (at a flow rate of 100 lmin) bull 40 VA
Environment characteristicsOperating temperature bull minus 10 divide +40 deg C
Maximum humidity bull 90
Pressure bull 860 to 1060 hPA
Noise generated by the pump bull lt 55 dBA at 1 m
Mechanical characteristicsDimensions weight bull 241 times 108 times 160 mm 28 kg
Case material bull Plastic
Complete setbull Air sampler PVP-06bull AC power adapterbull Filters AFA-RSP-20 - 100 pcsbull Packaging for filters - 40 pcsbull Casebull Operation manualbull Calibration certificate
Optional equimpient bull Kit for sampling sorption columns of activated
carbon Ř head of sorption columns with protective
covers Ř activated charcoal SKT-3 - 1 pkg (02 L) Ř charocoal samples SC-13 - 8 pcs
bull Car charger bull Tipod bull Shoulder strapbull Calibration stand bull Filters AFA SI-20 - 100 pcs
Consumablesbull Aerosol filters AFA RSP-20bull Iodine filters AFA SI-20
SPC ldquoDozardquoRadiation monitoring equipment
74 75
Calibration of gamma dose and dose rate meters
Calibration ofbull Ambient equivalent dose H(10) meters (Sv Svh)bull Personal equivalent dose Hp(10) meters (Sv Svh)bull Exposure dose X meters (R Rh)bull Two sources in irradiator bull Select source and collimator opening using
tumbler
UPG-P DESKTOP GAMMA BEAM IRRADIATOR
Physical characteristicsRange of reproduced dose rate bull 05 μSvh divide 10 mSvh (50 μRh divide 100 mRh)
Sources activities bull 6times106 6times108 Bq (02 20 mCi) Cs-137
Overall dimensions bull 1250times400times300 mm
Irradiator weight bull Not more than 37 kg
Calibration bench weight bull Not more than 15 kg
Reference standards IEC 60846 IEC 61526
Physical characteristicsDetectorbull Silicon
Measurement range EEC measurement bull Measurement range of radon EEC
10 divide 10bull106 Bqbullm-3
bull Measurement range of thoron EEC 05 divide 10bull104 Bqbullm-3
bull Air flow through the filter 100plusmn05 lmin
Concentration measurementbull Measurement range of radon-222 concentration
in air 10 divide 20bull106 cpsbull Measurement range of 216Po(ThA)
1bull10-3 divide 1bull102 cpsbull Air sampler flow rate
10plusmn02 lminbull Measurement range of radon-222 concentration
in water samples 6 divide 800 Bqbullkg-1
bull Measurement range of radon-222 flux from soil surface 20 divide 103 mBqsbullm2
bull Measurement range of radon-222 concentration with preliminary sampling of air using air sam-plers 20 divide 107 Bqbullm-3
bull Measurement range of radon-222 concentration in samples of soil air 103 divide 106 Bqbullm-3
Operation temperature range bull 1 divide 35 ordmC
Electrical characteristicsPower supply bull 80 VA
Mechanical characteristicsOverall dimensions weight bull 220times200times165 mm 36 kg
ldquoALPHARAD PLUSrdquoRADON THORON amp THEIR PROGENY MONITORbull Measurement of radon and thoron concentration
and effective equivalent concentration (EEC)bull In the airbull In the indoor air of residential public and industri-
al buildings and structuresbull Measurement of radon in drinking water sourcesbull Measurements of radon flux from the soil surface
at land plots allocated for construction of houses public buildings and industrial facilities
bull Measurements of radon concentration in soil air
Reference standards IEC 61577
SPC ldquoDozardquoRadiation monitoring equipment
76 77
UKPN-2M-D NEUTRON BEAM IRRADIATOR
Reference standards IEC 61005 61322
Calibration of neutron dose and dose rate meters
Calibration ofbull Ambient equivalent dose H(10) meters (Sv Svh)bull Personal equivalent dose Hp(10) meters (Sv Svh)bull Flux density of neutrons (cm-2∙s-1)bull Transfer container for temporary storage of
sources bull Red light signal of source working position
Physical carachteristicsRange of reproduced dose ratebull 20 divide 800 μSvh
Range of reproduced flux densitiesbull 10 divide 400 cm-2∙s-1
Type of a source in use bull Pu-Be
Activity of a source in usebull 24х1011 Bq (with density of 107 s-1)
Overall dimensions weight no morebull 3000x750x2000 mm 300 kg
Required room dimensionsbull not less than 7x3x3 m
Electrical characteristicsPower supply bull 220 V 50 Hz
Calibration of gamma dose and dose rate meters
Calibration ofbull Ambient equivalent dose H(10) meters (Sv Svh)bull Personal equivalent dose Hp(10) meters (Sv Svh)bull Exposure dose X meters (R Rh)bull Four sources in irradiator bull Select source and move to working position
return to storage position using special rodbull Transfer container for temporary storage of
sources bull Red light signal of source working position
UPGD-2M-DGAMMA BEAM IRRADIATOR
Physical characteristicsRange of reproduced dose rate bull 05 μSvh divide 50 mSvh (50 μRh divide 5 Rh)
Maximum activity of source bull 2times1011 Bq (50 Ci) Cs-137
Overall dimensionsbull Irradiator 800times500times500 mmbull Guide rails length 30 mbull Height 16 mbull Weight not more than 700 kgbull Required room dimensions not less than 7x3x3 m
Electrical characteristicsPower supply bull 220 V 50 Hz
UPGD-2M-D
Reference standards IEC 60846 IEC 61526 IEC 61066
SPC ldquoDozardquo
78 79
Contents
MEASURING UNITS
DBG-S11D wide range gamma area monitor 40
UDKS-100 gamma and X-ray area monitor 41
UDMN-100 neutron area monitor 41
ALARM UNITS
BAS-2 ldquoMICROrdquo external visual alarm 42
BZS-2 ldquoMicrordquo external audible alarm 42
Illuminated warning signs 43
ldquoImpulsrdquo external display unit 43
UIM-3D area monitor count rate meter 44
DKG-05D personal gamma dosimeter 46
DVS-02D gamma-neutron personal electronic dosimeter 47
DVGI-8D new pen-type personal ionization chamber dosimeters 48
DKG-02U ldquoARBITERrdquo wide range gamma-dosimeter 49
DKG-07D ldquoDROZDrdquo gamma-dosimeter 50
MKS-15D ldquoSNEGIRrdquo multi ndash purpose radiation survey meter 51
SRPS-05D gamma monitor 52
DOZA-TLD multipurpose TLD system 53
DKS-96 universal radiation survey meter 54
EXTERNAL PROBES ALPHA
Alpha BDZA-96 55
Alpha BDZA-96B 55
Alpha BDZA-96M 55
Alpha BDZA-96S 55
Alpha BDZA-96T 55
EXTERNAL PROBES BETA
Beta BDZB-96 56
Beta BDZB-99 56
Beta BDZB-96B 56
Beta BDZB-96S 56
EXTERNAL PROBES GAMMA
Gamma BDKS-96B 57
Gamma and beta BDKS-96S 57
Gamma BDMG-96 57
EXTERNAL PROBES GAMMA
Gamma-search BDVG-96 58
Gamma-search BDPG-96 58
ContentsRadiation monitoring systemldquoPELIKANrdquo Radiation monitoring system (RMS) 6
BDMG-101 high range gamma area monitor 10
DBG-S11D wide range gamma area monitor 11
BDRG-52 high range gamma area monitor for accident and post-accident conditions 12
UDGP-01 Liquid technological environments monitor 13
UDMN-100 neutron area monitor 14
UDKG-100 Wel Liquid gamma monitor 14
BOP-1M data processing and transmission unit 15
UDA-1AB particulate monitor 16
UDG-1B noble gas monitor 17
UDG-03D noble gas monitor 18
UDI-1B iodine monitor 19
UDGB-01 noble gasesH-3C-14 monitor 20
UDGP-01 steam generator leakage monitor 21
UPPVM air flow parameters monitor 22
ldquoIMPULSrdquo external display unit 23
BI-2 remote display amp alarm unit 24
BASBAS-1s external alarm 25
SKGAV stack monitor 26
RMS software 28
RMS workstation ndash operator console 29
Configurator software 29
RM RACK radiation monitoring rack 30
SRKS-01D criticality accident alarm system 32
ldquoATLANT-Mrdquo environmental radiation monitoring system 34
ldquoBREEZErdquo high-volume air sampler 35
ldquoGAMMA-SENSORrdquo gamma-survey system 36
Radiation monitoring equipmentAREA MONITOR ldquoFREGATrdquo 38
BPI-1D local display unit 39
80
Gamma-search BDPG-96M 58
Gamma BDKG-96 stainless steel casing for geologic applications well logging 59
EXTERNAL PROBES NEUTRON
Neutron BDMN-96 59
Neutron-search BDKN-96 59
RZB-05D Hand-foot-clothing monitor 60
RZBA-04-04M whole body contamination monitor 61
RZA-05D alpha hand-monitor 62
UMF-2000 low level alpha- beta- counter 63
DRK dose area product meter 64
ldquoPROGRESS-BETArdquo scintillation beta spectrometer 65
ldquoPROGRESS-GAMMArdquo scintillation gamma spectrometer 66
ldquoPROGRESS-G(P)rdquo portable scintillation gamma spectrometer 67
ldquoPROGRESS-ARrdquo alpha radiometer 68
ldquoPROGRESSrdquo whole body counter 69
MKG-01D ldquoSADOVNIKrdquo spectrometry system 70
MKS-01A ldquoMULTIRAD-ASrdquo alpha spectrometer 71
UCRV-2 airflow monitor 72
PVP-06 portable air sampler 73
ldquoALPHARAD PLUSrdquo radon thoron amp their progeny monitor 74
UPG-P desktop gamma beam irradiator 75
UPGD-2M-D gamma beam irradiator 76
UKPN-2M-D neutron beam irradiator 77
Radiation monitoring system SPC ldquoDozardquo
18 19
Physical characteristicsbull Scintillation detectors CsI(Tl) (2 pcs for measure-
ment and for background compensation)bull Cartridge activated charcoal
Measurement range bull 37 divide 37106 Bqm3
Energy range bull 006 divide 30 MeVbull Air flow rate 20 divide 40 lminbull Operation temperature range minus 10 divide +50 ordmС
Electrical characteristicsbull Power supply 85 divide 260 V 47 divide 440 Hzbull Interfaces RS-232 2timesRS-485 Ethernetbull Programmable relay output (SPDT relay)bull Analog output 4-20 mA (optional)
Mechanical characteristicsbull Protection index IP 65bull Paint decontaminable
Overall dimensions weight bull Stationary version 448times323times479 mm 35 kgbull Mobile version with pump unit BN-1
448times468times950 mm 578 kg
Reference standards Nuclear IEC 60761 IEC 61171 EMC IEC 61010 IEC 61000-6-2 Seismic IEC 60980
Alarmbull Sound alarm 80 divide 100 dBA at distance 1 mbull Visual alarm green yellow redbull Connection of the external alarm unit of ldquoBASrdquo
type
Versionsbull Stationary versionbull Stationary version with pump unit BN-1bull Mobile version with pump unit BN-1
Сontinuous automatic monitoring radioiodine concentration in the air at working places and in ventilation ducts and stacksbull Measurement of volumetric activity of radionu-
clides I-131 I-132 I-133 I-135 in the airbull On line gamma spectrometrybull Gamma background compensation bull Performance self-test by means of Am-241 check
source implanted into the detectorbull Audible and visual alarm signals of the excess of
preset thresholdsbull Periodic calibration by means of standard source
UDI-1B IODINE MONITOR
Physical characteristicsbull Silicon detector 2 pcs (for measurement and for
background rejection)bull Air flow rate 10 divide 100 lminbull Operation temperature range minus 10 divide +50 ordmС
Measurement range bull 104 divide 11010 Bqm3
Energy rangebull 006 divide 30 MeV
Electrical characteristicsbull Power supply 120 Vbull Interface RS-485
Mechanical characteristicsbull Protection index IP 65bull Paint decontaminable
Overall dimensions weight bull 474х246х243 mm 295 kg
UDG-03D NOBLE GAS MONITOR
Measurement of volumetric activity of beta-emitting radioactive gases (argon krypton xenon) adapted to the measurement of the rapidly changing volume activity in various technological processesbull Gamma background compensationbull Periodic calibration by means of standard beta-
source
Reference standards Nuclear IEC 60761 IEC 62302 EMC IEC 61010 IEC 61000-6-2 Seismic IEC 60980
Radiation monitoring system SPC ldquoDozardquo
20 21
Continuous automatic monitoring of steam genera-tor primary to secondary leakagebull On line gamma spectrometrybull N-16 monitoringbull Performance self-test by means of Am-241 check
source implanted into the detectorbull Audible and visual alarm signals of the excess of
preset thresholds
Physical characteristics
UDGP-01 STEAM GENERATOR LEAKAGE MONITOR
bull detector ndash scintillator CsI Oslash 40х100 mm
Measurement range bull High energy gamma-activity (N-16)
15bull103 divide 20bull108 Bqm3
bull General gamma-activity 10bull104 divide 20bull108 Bqm3
Energy range bull General gamma 005 divide 15 MeV bull in integral spectral band of energy
5000 divide 7200 keV bull temperature range minus 10 divide +80 ordmС
BOP-1SP
Electrical characteristicsbull Power supply 85 divide 260 V 47 divide 440 Hzbull Interfaces RS-232 RS-485 Ethernetbull programmable relay output (SPDT relay)
Mechanical characteristicsbull Protection index IP 65bull Paint decontaminable
Overall dimensions weight bull Detector unit Oslash 60x360 mm17 kgbull Data processing and transmission unit BOP-1sp
280x220x114mm 43 kgbull Collimator Oslash 350x455 mm 150 kg
Alarmbull Sound alarm 80 divide 100 dBA at distance 1 mbull Visual alarm green yellow redbull Connection of the external alarm unit of ldquoBASrdquo
type
Reference standards Nuclear IEC 61453 EMC IEC 61010 IEC 61000-6-2 Seismic IEC 60980Reference standards Nuclear IEC 60761 IEC 60710 IEC 60951-2 EMC IEC 61010 IEC 61000-6-2 Seismic IEC 60980
Ionization chambe 10 liters
UDGB-01T1
Physical characteristicsbull Detectors - stainless steel ionization chambersbull Air flow rate 10 divide 100 lminbull Operation temperature range minus 10 divide +50 ordmС
Volumes of ionization chambers bull UDGB-01T UDGB - 01T1 100 litersbull UDGB-01T2 01 liter
Measurement range (Kr-85) bull UDGB-01T UDGB-01T1 10104 divide 50109 Bqm3
bull UDGB-01T2 109 divide 501014 Bqm3
Measurement range (H-3) bull UDGB-01T UDGB-01T1 50104 divide 50109 Bqm3
bull UDGB-01T2 50109 divide 501014 Bqm3
Electrical characteristicsbull Power supply 85 divide 260 V 47 divide 440 Hzbull Interfaces RS-232 2timesRS-485 Ethernetbull Programmable relay output (SPDT relay)bull Analog output 4-20 mA (optional)
Mechanical characteristicsbull Protection index IP 23bull Paint decontaminable
Continuous automatic monitoring of the beta-emitting radioactive gases including tritium and carbon-14 concentration in the air at working places and in ventilation ducts and stacksbull Audible and visual alarm signals of the excess of
preset thresholds bull Monitoring of the noble gase activity in gaseous
effluents and ventilation air for accident and post-accident conditions
Overall dimensions weight bull UDGB-01T 381times343times716 mm 30 kgbull UDGB-01T1 260times320times175 mm 125 kgbull Ionization chamber 100 liters Oslash 250times600 mm
6 kgbull UDGB - 01T2 381times343times716 mm 27 kg
Alarmbull Sound alarm 80 divide 100 dBA at distance 1 mbull Visual alarm green yellow redbull Connection of the external alarm unit ldquoBASrdquo type
Versionsbull UDGB-01T - with built-in ionization chamber
100 litersbull UDGB-01T2 - with built-in ionization chamber
01 literbull UDGB-01T1 - with remote ionization chamber
100 liters
UDGB-01NOBLE GASESH-3C-14 MONITOR
Radiation monitoring system SPC ldquoDozardquo
22 23
Physical characteristicsLength of communication cablebull up to 1200 m
Character height bull ldquoImpuls-910-Rrdquo 100 mmbull ldquoImpuls-915-D4Srdquo 150 mmbull ldquoImpuls-927-D4Srdquo 270 mm
Operating temperature rangebull ldquoImpuls-910-Rrdquo 0 divide +50 ordmCbull ldquoImpuls-915-D4Srdquo ldquo-927-D4Srdquo minus 40 divide +50 ordmC
Electrical characteristicsbull Power supply 220 V 50 Hz
Mechanical characteristicsProtection index bull ldquoImpuls-910-R IP 44bull ldquoImpuls -915-D4Srdquo ldquo-927-D4Srdquo IP 65
Overall dimensions weight bull ldquoImpuls-910-Rrdquo 400times160times60 mm 3 kgbull ldquoImpuls -915-D4Srdquo 815times250times80 mm 5 kgbull ldquoImpuls -927-D4Srdquo 1250times330times80 mm 5 kg
ldquoIMPULSrdquoEXTERNAL DISPLAY UNIT
Display of data received from monitors of RMS
External display unit ldquoImpuls-910-Rrdquo
Reference standards EMC IEC 61010 IEC 61000-6-2 Seismic IEC 60980
Continuous monitoring of the flow rate temperature and humidity of the gas flowbull Definition of air volume flow rate in stacks taking
into account temperature and humidity of the air
UPPVM AIR FLOW PARAMETERS MONITOR
Physical characteristicsMeasurement range bull air flow velocity 1 divide 20 msbull air temperature 0 divide +80 ordmСbull air humidity 10 divide 95
Electrical characteristicsbull Power supply 220 V 50 Hz bull Interfaces RS-232 Ethernet
Mechanical characteristicsProtection index bull BSPP-1st BSPP-1tv BOP-1s IP 65bull PP-st IPTV IP 54bull Paint decontaminable
Overall dimensions weight bull air velocity probe PP-st 60times38times136 mm 015 kgbull Interface block BSPP-1st 125times155times73 mm 07 kgbull air temperature and relative humidity probe
IPTV-056-A 333times100times60 mm 07 kgbull Interface block BSPP-1tv 125times155times73 mm 07 kgbull Data processing and transmission unit BOP-1s
280x233x111 mm 8 kg
Reference standards Nuclear ISO 2889 EMC IEC 61010 IEC 61000-6-2 Seismic IEC 60980
BOP-1S
Radiation monitoring system SPC ldquoDozardquo
24 25
BASBAS-1S EXTERNAL ALARM
Generation of audible and visual signals of the excess of preset thresholds RMS monitorsbull Audible alarm 80 divide 100 dBA at distance 1 mbull Visual alarm green yellow red
Distance from RMS monitorbull BAS up to 20 mbull BAS-1s up to 1200 m
Power supply bull 220 V 50 Hz
Overall dimensions weight bull BAS 145times108times460 mm 18 kg bull BAS-1s 166times109times466 mm 18 kg
Reference standards EMC IEC 61010 IEC 61000-6-2 Seismic IEC 60980
Physical characteristicsLength of communication cablebull up to 1200 m
Displayed page size bull 4 lines of 20 characters
Volume of loaded information bull 10 pages
Change of pagesbull programmed or by pressing a button
Operating temperature rangebull minus 40 divide +50 ordmC
Electrical characteristicsbull Power supply 9 divide 18 VDCbull Interfaces RS-485
Mechanical characteristicsbull Protection index IP 65bull Overall dimensions weight 222times164times73 mm
40 kg
BI-2 REMOTE DISPLAY amp ALARM UNIT
bull Display of data received from monitors of RMSbull Audible and visual alarms on exceeding preset
thresholds of the RMS equipment bull Individual threshold setting for each measure-
ment channelbull Audible alarm 80 divide 100 dB at a distance of 1 m bull Visual alarm red yellow green
Reference standards EMC IEC 61010 IEC 61000-6-2 Seismic IEC 60980
Radiation monitoring system SPC ldquoDozardquo
2726
Electrical characteristicsbull Power supply 220 V 50 Hz bull Interfaces RS-232 RS-485 Ethernetbull programmable relay output (SPDT relay)
Alarmbull Sound alarm 80 divide 100 dBA at distance 1 mbull Visual alarm green yellow redbull Connection of the external alarm unit ldquoBASrdquo type
Related monitors and equipmentsbull UDA-1AB particulate monitorbull UDG-1B noble gas monitorbull UDI-1B iodine monitorbull UPPVM air flow parameters monitorbull Sampling and sample separation rack
Air flow parameters monitor rack
Reference standards Nuclear IEC 60761 IEC 61171 IEC 61172 IEC 62302 ISO 2889 EMC IEC 61010 IEC 61000-6-2 Seismic IEC 60980
Sampling and sample separation rack
Continuous monitoring of radioactivity in gaseous effluentsbull Automatic monitoring of the alpha- and beta-
radioactive aerosol noble gas and radioiodine concentrations in the air in ventilation ducts and stacks
bull Monitoring of the flow rate temperature and humidity of the gas flow
bull Separation of gaseous effluent into targeted fractions by means of a two-stage filter
bull Reversion of gas after analysis to the ventilation system
Physical characteristics
Particulate (UDA-1AB)bull Silicon specrometric detectors (2 pcs for measure-
ment and for gamma-background compensation) bull Filter tape types LFAS FSLWbull Tape consumption (when continuous operation)
10 m50 days
Measurement range bull Alpha 10-2 divide 2105 Bqm3 bull Beta 10-1 divide 106 Bqm3
Energy range bull Alpha 30 divide 90 MeV bull Beta 005 divide 30 MeV
Noble gas (UDG-1B)bull silicon detectors (2 pcs for measurement and for
gamma-background compensation)
Measurement range bull 104 divide 6109 Bqm3
Energy range bull 008 divide 30 MeV
Iodine (UDI-1B)bull scintillation detectors CsI(Tl) (2 pcs for measure-
ment and for background compensation)
SKGAV STACK MONITOR
Particulate noble gas and iodine monitors rack
Measurement range bull 37 divide 37105 Bqm3
Energy range bull 015 divide 30 MeV
Air flow parameters (UPPVM)Measurement range bull air flow velocity 1 divide 20 msbull air temperature 0 divide +80 ordmСbull air humidity 10 divide 95
Radiation monitoring system SPC ldquoDozardquo
28 29
CONFIGURATOR SOFTWAREMaintenance and set-up softwarebull Set-up and verify RMS monitorsbull Control testing adjustment and repair of RMS
monitorsbull Monitors measurement results archive receive
and View bull Communication through RS-232
RMS WORKSTATION ndash OPERATOR CONSOLEOrganization of interaction of the RMS Server and Monitors
Single monitor console includes vandal-proof key-board amp UPS
Reference standard IEC 61559-1 IEC 61559-2
RMS SOFTWAREData acquisition storing and visual representation RMS monitors measurement resultsbull Ethernet IEEE 8023 networkbull Clientserver architecturebull TCPIP protocolbull Oracle based Data Basebull Supremal by means InSat MasterSCADA
Radiation monitoring system SPC ldquoDozardquo
30 31
Delivery setComposition and modification depend on the tasks to be solved using the RM Rack
The rack which is an integral part of RM Rack accommodatesbull Monitors UDA-1AB UDG-1B UDG-03D UDI-1B
UDGB-01Tbull DBG-S11D Wide range gamma area monitor
BDMG-101 High range gamma area monitor UDMN-100 Neutron area monitor BDRG-52R High range gamma area monitor
bull BI-2 Remote display amp alarm unitbull Pump unit BN-01bull Data processing and transmission unit BOP-1Mbull External alarm BAS or BAS-1sbull Equipment of sampling line (flow meters ball
valves filter holder piping solenoid valve)bull Switchboard (intended for switching of all equip-
ment and transfer of data to the upper level via the unified communication channel)
RM RACK RADIATION MONITORING RACK
The radiation monitoring rack (RM Rack) is designed for continuous monitoring of radiation parameters in premises and technological systems at nuclear facil-ities RM Rack can be used as a structural element of the lower-level of RMS at nuclear power plants and other nuclear facilities that involved in obtaining processing use and storage of radioactive materials
FeaturesContinuous automatic monitoring of the alpha- and beta- radioactive aerosol beta-emitting radioactive gases and radioiodine concentrations in the working air and in the air in stacks and others radiation parameters in the facilities
The stand providesbull Primary processing storage and transmission of
measured and related data into the information channel based on the Ethernet IEEE 8023 inter-face (TCPIP protocol)
bull Transfer of required data to the location where the equipment is installed via technological channels based on RS-232 interface
bull Generation of audible and visual warning alarm signals when the preset thresholds are exceeded
bull Display of received data on the LCD
Radiation monitoring system SPC ldquoDozardquo
32 33Reference standards IEC 60860 ANSIANS-83 ISO 7753
Purposebull Detection and recording of criticality accident
(CA) by measuring the absorbed dose rate of gamma-neutron radiation in the premises of monitored object its comparison with a threshold value and generation of audible and visual signals
bull Automatic collection processing storage and display of measurement data and related infor-mation as visual and graphical representation for operators of nuclear safety service
Functions of the systembull Detection and recording of CA events by con-
tinuous measurement of absorbed dose rate of gamma radiation comparison of measured values with preset thresholds generation of signals to activate the alarm
bull Activation of audible visual alarmbull In the event of CA turning on warning signals
ldquoDO NOT ENTERrdquo at illuminated information pan-els placed at the entrances to the controlled area
Featuresbull Data can be transferred to external data commu-
nication channel using RS-485 interface (DiBus data exchange protocol)
bull Automatic self-testing of detection units BR-04D with display of information about the type of fault
bull Possibility for connecting additional a detection and alarm units
bull Ability to function in general regardless of the functioning of components within the agreed scope of nuclear safety tasks
bull Radiation hardness up to 100 Gy
SRKS-01DCRITICALITY ACCIDENT ALARM SYSTEM
Features of softwarebull Collection of information via RS-485 network
displaying it on the PC monitor transmission to remote users archiving and storage
bull Status monitoring and display of values measured by BR-04D and DBG-S11D in locations as per layout of premises
bull Access to archived data with possibility to gener-ate reports for periods determined by operator
bull Maintenance and archiving of a log of dosimetric measurements data and events along with their time stamps
bull Possibility to transfer data to external users via Ethernet network for integrating of CA into higher level systems
Basic complete setLower level bull Control unit with power supplybull BR-04D detection unitsbull BZS-01D audible alarm unitsbull BSS-01D visual alarm unitsbull SIT-01D illuminated warning signsbull PBZ panels for muting audible alarmbull Network communication module
Additional lower layer devicesbull DBG-S11D wide range gamma area monitor
Upper layer bull CDP central display panelbull Service workstation
RS-485
RS-485
RS-4
85
Audible alarm units BZS-01D
Illuminated warning signs SIT-01D
Detection units BR-04D
Network communication
moduleDBG-S11D wide range gamma area monitor
Panels for muting audible alarm
Control unit with power supply
Visual alarm units BSS-01D
RS-485
RS-485
RS-4
85
Audible alarm units BZS-01D
Illuminated warning signs SIT-01D
Detection units BR-04D
Network communication
moduleDBG-S11D wide range gamma area monitor
Panels for muting audible alarm
Control unit with pow-er supply
Visual alarm units BSS-01D
RS-485
RS-4
85
Audible alarm units BZS-01D
Illuminated warning signs SIT-01D
Detection units BR-04D
Network communication
moduleDBG-S11D wide range gamma area monitor
Panels for muting audible alarm
Control unit with power supply
Visual alarm units BSS-01D
RS-485
RS-485
RS-4
85
Audible alarm units BZS-01D
Illuminated warning signs SIT-01D
Detection units BR-04D
Network communication
moduleDBG-S11D wide range gamma area monitor
Panels for muting audible alarm
Control unit with power supply
Visual alarm units BSS-01D
Ethernet
Central display panel Service workstation
RS-485
RS-485
RS-4
85
BZS-01D audible alarm units
SIT-01D illuminated warning signs
BR-04D detection units
Network communication
moduleDBG-S11D wide range gamma area monitor
PBZ panels for muting audible alarm
Control unit with power supply
BSS-01D visual alarm units
Radiation monitoring system SPC ldquoDozardquo
34 35
ldquoBREEZErdquoHIGH-VOLUME AIR SAMPLER
Physical characteristicsbull Measurement range of air flow rate
250 divide 1200 m3hbull Continuous operation time not less than 24 h
Filter materialsbull High-purity glass fiberbull Pure quartz or cellulosebull Filter fabric FPP-15-15
Electrical characteristicsPower supply bull 220380 V 50 Hz
Interfaces bull RS-485bull Ethernetbull GSMGPRS (option)
Environmental characteristicsTemperature range bull minus 40 divide + 40 ordmC
Relative humidity limit at 35 ordmC bull 95
Atmospheric pressure range bull 840 divide 1067 kPa
Versionsbull Standalone unit bull Part of Environmental Radiation Monitoring
System (ERMS)
Type of detection unitsbull Beta block BDZB-100Lbull DBG-S11D wide range gamma area monitorbull Scintillation spectrometric block
The motor of Air Sampler is controlled by an electronic flow sensor that detects changes in the operators pre-set flow rate caused by changes in temperature barometric pressure and pressure drop due to dust loading on filter media It compensates for these changes by adjusting the motor speed to maintain the pre-set flow ratebull Measurement of parameters of ionizing radiation bull Standalone mode of operation or as the part
of Environmental Radiation Monitoring System (ERMS)
Purposebull Environmental Radiation Monitoring System
(ERMS) in the control and buffer areas of the radia-tion and nuclear facilities
Referencesbull Since the year 2000 the system is successfully
operating the ERMSs at 8 Russian nuclear power plants (about 180 monitoring stations)
bull Since the year 2005 the ERMS is operating in the Moscow (about 40 monitoring stations)
bull Since the year 2005 the regional ERMS is under operation in several Russian Federation regions
Basic complete setMonitoring stations bull Data processing and transmission unit BOP-1TA bull Gamma area monitor DBG-S11D
Central data processing station (CDPS)bull Data processing and transmission unit BOP-1TAbull Server
By requestbull Emergency Response and Crisis Management
Centers for enterprisesbull Regional Emergency Response and Crisis Manage-
ment Centersbull rdquoBreezerdquo High-Volume Air Samplerbull Mobile lab with gamma-survey system rdquoGammandash
sensorrdquo
ldquoATLANT-MrdquoENVIRONMENTAL RADIATION MONITORING SYSTEM
Monitoring system for the continuous radiation monitoring of territories and facilities with the data transmission GSMGPRS network
Data transmission bull GSMGPRS
Power supply bull 220 V 50 Hz
Continuous autonomous operation (at 20 ordmC)bull From built-in battery not less than 5 hoursbull From external battery not less than 24 hours
Operation temperature bull Minus 40 divide +50 ordmC
Operation humidity bull Up to 98
Protection bull IP65
Reference standards Nuclear IEC 61017-11991 IEC 61017-21994
36
Radiation Monitoring Equipment
bull Localization of radioactive contaminationsbull Database with dose rate contaminations
spectra measurement date amp time coordi-nates
bull Work as part of mobile laboratory or as part of Environmental Radiation Monitoring System with real-time data transfer
Physical characteristicsDetector bull Scintillation NaI (Tl) GM counters
Measurement rangebull 01 ndash 107 μSvh
Energy range bull 005 ndash 3 MeV
Operation temperature range bull minus 10 divide +50 ordmС
Electrical characteristics bull Power supply 220 V 50 Hz
ldquoGAMMAndashSENSORrdquoGAMMA-SURVEY SYSTEM
SPC ldquoDozardquoRadiation monitoring equipment
38 39
AREA MONITOR ldquoFREGATrdquoArea Monitor ldquoFregatrdquo is designed for building rela-tively simple and inexpensive radiation monitoring systems at such facilities as radionuclide sources storage areas isotope products warehouses nuclear medicine departments PET centers calibration laboratories where sources of ionizing radiation are used etc
Small scale automated radiation monitoring systems built with ldquoFregatrdquo components featuring audible and visual alarms are matched suitable to meet the regulatory radiation safety requirements
Area monitor ldquoFregatrdquo requires virtually no adjust-ment it is simple and convenient for installation and operation
BPI-1D LOCAL DISPLAY UNIT
Display of monitored parameters values received from external measuring devices
Purposebull Processing and display of values of monitored
parameters on information panel bull Comparison of values of monitored parameters
with thresholdsbull Transfer of monitored parametersrsquo values to
networkbull Generation of alarm in case of exceeding of preset
thresholds including external alarm devices
FeaturesTesting the unit and connected devicesbull Visually on the panelbull Using adjustment software when connected to
PC via USB
Automatic self-testing
The panel displays the following informationbull Diagnostic information about the status of con-
nected devicesbull Current date and timebull Values of measured parametersbull Position of measured values with respect to the
thresholds in the form of scales with green yellow and red zones
bull Time history (trend) for each measured value
Physical characteristicsTemperature range bull minus 10 divide + 50 ordmC
Maximum number of connected devicesbull measuring devices 15bull external audible and visual alarm 15
Display diagonal bull 152 cm (6)
Electrical characteristicsbull Interfaces RS-485bull Power supply 220 V 50 Hz 12 divide 24 V
Mechanical characteristicsbull Protection index IP54bull Paint decontaminable
Overall dimensions weightbull 296x248x118 mm 5 kg
DBG-S11D wide range gamma area monitor
UDMN-100 neutron area monitor
Ethernet RS-485
UDKS-100 gamma and X-ray area monitor
BPI-1D Local display unit
BAS-2 ldquoMicrordquo external visual alarm
BZS-2 ldquoMicrordquo external audible alarm
ldquoImpulsrdquo external display unit
Service workstation
Illuminated warning signs
SPC ldquoDozardquoRadiation monitoring equipment
4140
Continuous automatic monitoring of the gamma- X-ray ambient dose equivalent rate
Physical characteristicsbull Detector tissue-equivalent plastic scintillator
Oslash 45times20 mm
Measurement range bull Dose rate measurement range 01 μSvh divide 1 Svh bull Energy range 0015 divide 10 MeV
Mechanical characteristicsbull Protection index IP65bull Paint decontaminable
Overall dimensions weightbull Oslash72times265 mm 15 kg
UDKS-100 GAMMA AND X-RAY AREA MONITOR
UDMN-100 NEUTRON AREA MONITOR
Physical characteristicsbull detector ndash scintillator ZnS(Ag) Li-6
Measurement range bull 01 μSvh divide 01 Svh
Energy range bull 0025 eV divide 100 MeV
Temperature range bull minus 45 divide +50 ordmC
Electrical characteristicsbull Interfaces RS-485
Mechanical characteristicsbull Protection index IP 65bull Paint decontaminable
Overall dimensions weight bull 428times258times347 mm 115 kg
Continuous automatic monitoring of the neutron-radiations ambient dose equivalent ratebull Spherical polyethylene moderator Oslash 239 mm
MEASURING UNITS
DBG-S11D WIDE RANGE GAMMA AREA MONITOR
Continuous automatic monitoring of the gamma- ambient dose equivalent rate
Physical characteristicsbull Detector ndash GM counters
Measurement rangebull DBG-S11D 01 μSvh divide 10 mSvhbull DBG-S11D-01 01 μSvh divide 10 Svhbull DBG-S11D-02 01 μSvh divide 100 Svh
Energy rangebull 005 divide 30 MeV
Temperature range bull minus 40 divide +50 ordmC
Electrical characteristicsbull Interfaces RS-485 USB
Mechanical characteristicsbull Protection index IP 68bull Paint decontaminable
Overall dimensions weightbull DBG-S11D Oslash 68times141 mm 065 kg bull DBG-S11D-01 Oslash 68times179 mm 07 kgbull DBG-S11D-02 Oslash 68times179 mm 07 kg
Versionsbull DBG-S11Dbull DBG-S11D-01bull DBG-S11D-02
Reference standards Nuclear IEC 60846 IEC 60532 EMC IEC 61010 IEC 61000-6-2 Seismic IEC 60980
SPC ldquoDozardquoRadiation monitoring equipment
4342
ALARM UNITS
Generation visual signals of the excess of preset thresholds
Physical characteristicsLength of communication cablebull up to 1200 mbull Alarm Visual alarm green yellow red
Electrical characteristicsbull Power supply +12 V
Mechanical characteristicsbull Protection index IP 23
Overall dimensions weight 160times84times41 mm 02 kg
BAS-2 ldquoMICROrdquo EXTERNAL VISUAL ALARM
Generation audible signals of the excess of preset thresholds
Physical characteristicsLength of communication cablebull up to 1200 mbull Audible alarm 80 divide 100 dB at a distance of 1 m
Electrical characteristicsbull Power supply +12 V
Mechanical characteristicsbull Protection index IP 23
Overall dimensions weight 160times84times41 mm 02 kg
BZS-2 ldquoMICROrdquo EXTERNAL AUDIBLE ALARM
Physical characteristicsLength of communication cablebull up to 1200 m
Electrical characteristicsbull Power supply 220 V 50 Hz
Mechanical characteristicsbull Protection index IP 23
Overall dimensions weight bull 330times110times20 mm 05 kg
Physical characteristicsLength of communication cablebull up to 1200 m
Character height bull ldquoImpuls-910-Rrdquo 100 mmbull ldquoImpuls-915-D4Srdquo 150 mmbull ldquoImpuls-927-D4Srdquo 270 mm
Operating temperature rangebull ldquoImpuls-910-Rrdquo 0 divide +50 degCbull ldquoImpuls-915-D4Srdquo ldquo-727-D4Srdquo minus 40 divide +50 degC
Electrical characteristicsbull Power supply 220 V 50 Hz
Mechanical characteristicsProtection index bull ldquoImpuls-910-R IP 44bull ldquoImpuls-915-D4Srdquo ldquo-727-D4Srdquo IP 65
Overall dimensions weight bull ldquoImpuls-910-Rrdquo 400times160times60 mm 3 kgbull ldquoImpuls-915-D4Srdquo 815times250times80 mm 5 kgbull ldquoImpuls-927-D4Srdquo 1250times330times80 mm 5 kg
ILLUMINATED WARNING SIGNS
ldquoIMPULSrdquo EXTERNAL DISPLAY UNIT
SPC ldquoDozardquoRadiation monitoring equipment
4544
Individual threshold setting for each measurement channel
Continuous area and process monitoring
Collect amp display data from two measurement chan-nels (units with RS-485 or analog pulses)
Audible and visual alarms on exceeding preset thresholds or status of connected devices
Individual threshold setting for each measurement channel
Switching on the external alarm or executive devices when any threshold is exceeded
The wide panel displays the following information bull Values of measured parameters as min-1∙cm-2
s-1∙cm-2 μSvhbull Diagnostic information about the status of con-
nected devicesbull Current date and timebull Position of measured values with respect to the
thresholds in the form of scales with green yellow and red zones
bull Time history (trend) for each measured value
Physical characteristics Measurement range bull Count rate up to 107 CPM (170 kHz)
Operating temperature range bull minus 20 divide +50 ordmC
Electrical characteristics bull Power supply 220 V bull Interfaces USB
Mechanical characteristics bull Protection index IP 65 bull Overall dimensions weight 222times164times73 mm
40 kg
UIM-3D AREA MONITOR COUNT RATE METER
Measurement of alpha radiation flux density
Detector unit BDZA-100 (70 cm2) Measurement range 01 divide 104 min-1∙cm-2
Detector unit BDZA-100B (300 cm2) Measurement range 01 divide 2103 min-1∙cm-2
Measurement of beta radiation flux density
Detector unit BDZB-100 (28 cm2) Measurement range 10 divide 105 min-1∙cm-2
Detector unit BDZB-100L (30 cm2) Measurement range 10 divide 104 min-1∙cm-2
Detector unit BDZB-11D (84 cm2) Measurement range 5 divide 15∙104 min-1∙m-2
OPTIONAL PROBESMeasurement of gamma radiation flux density
Detector units BDEG-03 Measurement range 4 divide 2000 s-1∙cm-2
Detector unit UDKG-100 for operation in the rocks ore liquid media and sludge Measurement range 40 divide 8000 s-1∙cm-2
Measurement of the ambient dose equivalent rate
Detector unit DBG-S11D Measurement range 01 μSvh divide 100 Svh
Measurement of neutron radiation ambient dose equivalent rate
Detector unit BDMN-100 Measurement range 01 μSvh divide 01 Svh
SPC ldquoDozardquoRadiation monitoring equipment
46 47Reference standards Nuclear IEC 61526
Measurement of gamma-radiation personal dose equivalent Hp(10)bull Stand-alone dosimeter or composed of dosimetric
system onebull Audible and visual alarmbull Large memory dose accumulation historiesbull Exclusion of unauthorized intervention in dosim-
etry operation
DKG-05D PERSONAL GAMMA DOSIMETER
Physical characteristicsDetectors bull Silicon
Measurement range bull Dose rate 1 μSvh divide 10 Svhbull Dose 01 μSv divide 15 Sv
Energy range bull 005 divide 30 MeV
Electrical characteristicsbull Power supply rechargeable NiMH battery 1
alcaline battery (type AAA)
Operation timebull Till recharging not less 400 hoursbull With one set batteries not less 1000 hours
Mechanical characteristicsOverall dimensions weight bull 47times26times87 mm (with clip) 70 g
Environmental characteristicsbull IP65bull Temperature range minus 20 divide +45 ordmCbull Humidity up to 98 at 35 ordmCbull Shock vibration and drop resistant
Alarmbull Excess of alarm thresholdsbull Warnings of self-test failure and battery discharge bull Audible alarm 80 dB at 40 cmbull Visual alarm blinking LED
Relative equipmentbull One dosimeter charger ZU-1Mbull Chargestorage cassetes KZU-28KZU-56bull ldquoSmart chargingrdquo feature extends battery life timebull DKG-05D reader US-05bull DKG-05D system reader DVS-01D
Reader-PC interfacebull US-05 USB bull DVS-01D Ethernet
KZU-28
Physical characteristicsDetectors bull Silicon Li-6
Gamma measurement range bull Dose rate 1 μSvh divide 10 Svhbull Dose 01 μSv divide 15 Sv
Gamma energy range bull 005 divide 60 MeV
Neutron measurement range bull Dose rate 1 μSvh divide 2 Svhbull Dose 20 μSv divide 15 Sv
Neutron energy range bull 0025 eV divide 20 MeV
Electrical characteristicsPower supply bull Rechargeable NiMH batterybull Operatiion time till recharging not less 200 hours
Mechanical characteristicsOverall dimensions weight bull 47times26times87 mm (with clip) 70 g
Environmental characteristicsbull IP65bull Temperature range minus 20 divide +40 ordmCbull Humidity up to 75 at 30 ordmCbull Shock vibration and drop resistant
Alarmbull Excess of alarm thresholds bull Warnings of self-test failure and battery discharge bull Audible alarm 80 dB at 40 cmbull Visual alarm blinking LED
Relative equipmentbull One dosimeter charger ZU-1Mbull Chargestorage cassetes KZU-28 KZU-56bull ldquoSmart chargingrdquo feature extends battery life timebull DVS-02D reader UZS-01Sbull DVS-02D system reader DVS-01D
Reader-PC interfacebull UZS-01S USB bull DVS-01D Ethernet
UZS-01DReference standards Nuclear IEC 61526
DVS-02D GAMMA-NEUTRON PERSONAL ELECTRONIC DOSIMETER
Measurement of gamma- and neutron radiations personal dose equivalent Hp(10)bull Stand-alone dosimeter or composed of dosimetric
system onebull Audible and visual alarmbull Large memory dose accumulation historiesbull Exclusion of unauthorized intervention in dosim-
etry operationbull Both albedo thermal neutrons and intermediate
fast neutrons registrationbull Usable in the fields of Pu(Be) Po(Be) Cf and other
neutron sources as well as near nuclear reactors without neutron spectrum estimation
SPC ldquoDozardquoRadiation monitoring equipment
48 49
Dosimeters DVG-03D
DVGI-8D NEW PEN-TYPE PERSONAL IONIZATION CHAMBER DOSIMETERS
Measurement of personal dose equivalent Hp(10) of gamma and X-ray radiationbull Hp(10) of continuous and pulsed gamma and
X-ray radiation bull Electronic reader KSU-1bull Dosimeter DVG-03D with electronic ID bull Personal dose histories in the readerrsquos memorybull Readerrsquos connection with PC for database main-
tenance
Physical characteristicsDetector bull Ionization chamber
Measurement range bull 001 mSv divide 25 mSv
Energy range bull 0015 divide 25 MeV
Temperature range bull Reader KSU-1 +10 divide +50 ordmСbull Dosimeter DVG-03D minus 40 divide +50 ordmС
Electrical characteristicsPower supply bull Reader KSU-1 220 V 50 Hz built-in batteries bull Dosimeter DVG-03D four batteries CR 1025 bull Batteries life 3 yearsbull Readers interfaces RS-232USB 20
Mechanical characteristicsOverall dimensions weightbull Dosimeter DVG-03D Oslash 18times126 mm 005 kgbull Reader KSU-1 235times232times125 mm 28 kg
Reference standards Nuclear IEC 62387-1
DKG-02U ldquoARBITERrdquo WIDE RANGE GAMMA-DOSIMETER
Physical characteristicsDetectors bull GM counters
Measurement rangebull Dose-rate 01 μSvh divide 3 Svhbull Dose 1 μSv divide 100 Sv
Energy range bull 005 divide 3 MeV
Electrical characteristicsbull Power supply 2 alcaline batteries (type AA)bull Batteries life not less 200 hours
Mechanical characteristicsOverall dimensions weight bull 152times82times32 mm 03 kg
Environmental characteristicsbull Temperature range minus 20 divide +50 ordmCbull Humidity up to 90 at +25 ordmCbull Shock vibration and drop resistant
Reference standards Nuclear IEC 60846
Measurement of gamma radiation ambient equiva-lent dose H(10) and dose rate H(10)bull Audible signals (clicks) for radiation condition
estimationbull Analog scale for search modebull Audible and visual alarms of the excess of preset
dose and dose rate thresholds bull Shock-resistant water-proof easy decontamina-
tion casebull 100 measurement results memory with date and
time of measurementbull Indication of total dose accumulated during
exploitation time bull Indication of measurement result statistical
uncertainty
SPC ldquoDozardquoRadiation monitoring equipment
50 51
Physical characteristicsDetectors bull GM counter
Measurement rangebull Dose-rate 01 μSvh divide 3 mSvhbull Dose 1 μSv divide 02 Sv
Energy range bull 005 divide 3 MeV
Temperature range bull Minus 20 divide +50 ordmC
Electrical characteristicsbull Power supply 2 alcaline batteries 15 V (type AA)bull Batteries life not less 200 hours
Mechanical characteristicsOverall dimensions weight bull 122times74times29 mm 025 kg
Reference standards Nuclear IEC 60846
DKG-07D ldquoDROZDrdquoGAMMA-DOSIMETER
Measurement of gamma radiation ambient equiva-lent dose H(10) and dose rate H(10)bull Two independent measurement channels dose
and dose ratebull Audible signals (clicks) for radiation condition
estimationbull Continuous measurement with updating meas-
urement resultbull Measurement result can be obtained with any
desired statistical uncertainty (error)bull Automatic restart when radiation level sharply
changesbull Indication of statistical uncertainty (error) during
measurement process
Continuous measurement with updating measure-ment result
Automatic restart when radiation level sharply changes bull Gamma dose H(10) and dose-rate H(10) meas-
urementbull Beta and gamma contamination surveybull Indication of statistical uncertainty during the
measurementbull Continuous measurement with accuracy increas-
ing with time bull Automatic restart triggered by change of gamma
dose-ratebull Compensation of gamma count rate while meas-
uring beta radiationbull Indication of battery charge levelbull Audible signal of the excess of preset threshold
Physical characteristicsDetectors bull GM counter
Measurement range bull Dose-rate 01 microSvh divide 20 mSvhbull Dose 1 microSv divide 100 Svbull Beta flux density (for Sr-90+Y-90)
10 divide 105 cm-2 min-1
Energy range bull Gamma 005 divide 3 MeVbull Beta 01 divide 3 MeV
Temperature range bull Minus 20 divide +50 ordmC
MKS-15D ldquoSnegirrdquo backside
MKS-15D ldquoSNEGIRrdquoMULTI ndash PURPOSE RADIATION SURVEY METER
Reference standards Nuclear IEC 60846 IEC 60325
Electrical characteristicsbull Power supply 2 alcaline batteries (type AA)bull Battery life not less 400 hours
Mechanical characteristicsOverall dimensions weight bull 124times72times35 mm 035 kg
SPC ldquoDozardquoRadiation monitoring equipment
52 53
Physical characteristicsDetectorbull GM counter
Measurement range bull 01 μSvh divide 20 mSvh
Energy range bull 005 divide 30 MeV
Threshold setting range bull 03 μSvh divide 20 mSvh
Step change of the thresholdbull In the range 03 divide 10 μSvh with the step
001 μSvhbull In the range 10 divide 100 μSvh with the step
01 μSvhbull In the range 100 divide 2000 μSvh with the step
10 μSvh
Electrical characteristicsPower supply bull 220 V 50 Hz bull Relay output
Mechanical characteristicsProtection index bull IP 40
Overall dimensions weight bull 226times120times75 mm 07 kg
Alarmbull Sound alarm 80 divide 100 dBA at distance 1 mbull Visual alarm redbull Connection of the external alarm signaling unit
Reference standards Nuclear IEC 60846 IEC 60532
Continuous automatic monitoring of the ambient dose equivalent rate bull Measurement of gamma dose rate H(10)bull Audible and visual alarm signals for preset
thresholdsbull Switching on the external signaling or executive
devices
SRPS-05D GAMMA MONITOR
Measurement ofbull Gamma and X-ray personal dose equivalent
Hp(10)bull Neutron personal dose equivalent Hp(10)bull Lens dose equivalent Hp(3)bull Skin dose equivalent Hp(007)bull TLD reader day-to-day tests using built-in LEDbull No needs nitrogen for heating
Physical charachteristicsDetectors bull 7LiF Mg Ti (gamma beta)bull 6LiF Mg Ti (neutron)
Gamma and X-ray Hp(10) Measurement range bull 500 μSv divide 10 Sv
Energy range bull 0015 divide 30 MeV
Neutron Hp(10)Measurement range bull 01 mSv divide 100 mSv
Energy range bull 0025 eV divide 10 MeV
Beta and photons Hp(007) Hp(3) Measurement range bull 2 mSv divide 100 Sv
Energy range bull Beta 025 divide 35 MeVbull Photons lt15 keV
Mechanical characteristicsDosimeters overall dimensions weight bull Gamma Hp(10) DTL-2 holder - 62times26times16 mm
16 gbull DTU holder - 42times28times18 mm 8 gbull Lens Hp(3) face skin Hp(007) Oslash 32times16 mm 9 gbull Finger skin Hp(007) 90times20times2 mm 1 gbull Neutron gamma Hp(10) 48times40times20 mm 30 g
Reference standards Nuclear IEC 61066
DTL-2 DTU-2
MKD (A-type) DVNG-M
DOZA-TLD MULTIPURPOSE TLD SYSTEM
SPC ldquoDozardquoRadiation monitoring equipment
54 55
Continuous and pulsed gamma and X-ray dose H(10) and dose-rate measurementbull Alpha beta and gamma contamination surveybull Neutron dose H(10) and dose-rate measurementbull Gamma radiation flux density in boreholes and
liquid media measurement
Electrical characteristicsPower supply bull UIK-05 four C-size batteriesbull UIK-05-01 rechargeable batterybull UIK-06 rechargeable battery
Interfaces bull RS-232bull USB (via adapter)
bull Detector type automatic determination and corre-sponding measurement modes selection
bull Alarm threshold settings ndash for dose dose-rate alpha and beta contaminations
bull ldquoDetectrdquo and ldquoLocaterdquo modes for survey probes
Reference standards Nuclear IEC 60846 IEC 60325 IEC 61005 IEC 62363
Case
UIK-06 control unit165times78times48 mm 03 kg
DKS-96UNIVERSAL RADIATION SURVEY METER
UIK-05 control unit202times86times90 mm 10 kg
BDZA-96
BDZA-96B
BDZA-96M
BDZA-96S
BDZA-96T
EXTERNAL PROBES ALPHAALPHA BDZA-96Detector bull ZnS(Ag) 70 cm2
Measurement range (for Pu-239)bull 01 divide 104 min-1cm-2
Overall dimensions weightbull Oslash 130times240 mm 11 kg
ALPHA BDZA-96BDetector bull ZnS(Ag) 300 сm2
Measurement range (for Pu-239)bull 01 divide 2103 min-1cm-2
Overall dimensions weightbull Oslash 230times290 mm 40 kg
ALPHA BDZA-96MDetector bull ZnS(Ag) 10 сm2
Measurement range (for Pu-239)bull 01 divide 105 min-1cm-2
Overall dimensions weightbull Oslash 65times240 mm 09 kg
ALPHA BDZA-96SDetector bull ZnS(Ag) 30 сm2
Measurement range (for Pu-239)bull 01 divide 5104 min-1cm-2
Overall dimensions weightbull Oslash 90times240 mm 10 kg
ALPHA BDZA-96TDetector bull Silicon 5 сm2
Measurement range (for Pu-239)bull 01 divide 106 min-1cm-2
Overall dimensions weightbull Oslash 50times60 mm 015 kg
SPC ldquoDozardquoRadiation monitoring equipment
56 57
BETA BDZB-96Detector Scintillator 28 сm2
Measurement range (for Sr-90+Y-90)bull 10 divide 105 min-1cm-2
Energy rangebull 03 divide 30 MeV
Overall dimensions weightbull Oslash 90times230 mm 09 kg
BETA BDZB-99Detector bull GM counter 30 сm2
Measurement range (for Sr-90+Y-90)bull 20 divide 104 min-1см-2
Energy rangebull 012 divide 30 MeV
Overall dimensions weightbull Oslash 88times80 mm 04 kgbull Telescopic pole length 07 m
BETA BDZB-96BDetector bull GM counter 80 сm2
Measurement range (for Sr-90+Y-90)bull 3 divide 104 min-1сm-2
Energy rangebull 012 divide 30 MeV
Overall dimensions weightbull 150times200times110 mm 15 kg
BETA BDZB-96Sbull Detector GM counter 15 сm2
Measurement range (for Sr-90+Y-90)bull 10 divide 3104 min-1cm-2
Energy rangebull 012 divide 30 MeV
Overall dimensions weightbull Oslash 65times65 mm 03 kgbull Telescopic pole length 07 m
BDZB-96
BDZB-99
BDZB-96B
BDZB-96S
EXTERNAL PROBES BETA
GAMMA BDKS-96BDetector bull Tissue-equivalent scintillator Oslash 45times20 mm
Measurement rangebull Dose rate H(10) 01 μSvh divide 1 Svhbull Dose H(10) 01 μSv divide 10 Sv
Energy rangebull 0015 divide 10 MeV
Overall dimensions weightbull Oslash 60times250 mm 085 kg
GAMMA AND BETA BDKS-96SDetector bull Double GM counters
Measurement rangebull Gamma dose rate H(10) 01 μSvh divide 1 mSvhbull Gamma dose H(10) 01 μSv divide 10 Svbull Beta 10 divide 3104 min-1cm-2
Energy rangebull Gamma 005 divide 3 MeVbull Beta 012 divide 3 MeV
Overall dimensions weightbull Oslash 80times80 mm 035 kgbull Telescopic pole length 07 m
GAMMA BDMG-96Detector bull GM counters
Measurement rangebull Dose rate H(10) 01 μSvh divide 10 Svhbull Dose H(10) 01 μSv divide 10 Sv
Energy range bull 005 divide 3 MeV
Overall dimensions weightbull 40times250 mm 05 kgbull Telescopic pole length 07 m 4 m (by request)
EXTERNAL PROBES GAMMA
BDKS-96B
BDMG-96
BDKS-96S
SPC ldquoDozardquoRadiation monitoring equipment
58 59
GAMMA-SEARCH BDVG-96Detector bull Scintillator NaI(Tl) Oslash 63times63 mm
Measurement rangebull Flux density measurement range 4 divide 2000 s-1cm-2
bull Dose rate H(10) for Cs-137 01 divide 30 μSvhbull Sensitivity for Cs-137 3000 (pulsess-1)( μSvh-1)
Overall dimensions weightbull Oslash 88times400 mm 20 kgbull Modular pole length 16 m
GAMMA-SEARCH BDPG-96Detector bull Scintillator NaI(Tl) Oslash 25times40 mm
Measurement rangebull Flux density measurement range 10 divide 8000 s-1cm-2
bull Dose rate H(10) for Cs-137 01 divide 100 μSvhbull Sensitivity for Cs-137 500 (pulsess-1)( μSvh-1)
Overall dimensions weightbull 50times190times480 mm 10 kgbull Telescopic pole length 07 m
GAMMA-SEARCH BDPG-96MDetector bull Scintillator NaI(Tl) Oslash 18times30 mm
Measurement rangebull Flux density measurement range 10 divide 24000 s-1cm-2
bull Dose rate H(10) for Cs-137 01 divide 300 μSvhbull Sensitivity for Cs-137 200 (pulsess-1)( μSvh-1)
Overall dimensions weightbull Oslash 35times320 mm 05 kgbull Telescopic pole length 07 or 38 m
EXTERNAL PROBES GAMMA
BDVG-96
BDPG-96M
BDPG-96
EXTERNAL PROBESGAMMA BDKG-96 STAINLESS STEEL CASING FOR GEOLOGIC APPLICATIONS WELL LOGGINGDetector bull Scintillator NaI(Tl) Oslash 18times30 mm
Measurement rangebull Flux density measurement range 10 divide 105 s-1cm-2
bull Dose rate H(10) for Cs-137 5 divide 2104 μRhbull Sensitivity for Cs-137 200 (pulsess-1)( μSvh-1)
Overall dimensions weightbull Oslash 38times535 mm 36 kgbull Cable length 10 divide 1000 m
NEUTRON BDMN-96Detector bull Scintillator with ZnS(Ag)
Measurement rangebull Dose rate H(10) 01 μSvh divide 01 Svhbull Dose H(10) 01 μSv divide 10 Sv
Energy range bull 0025 eV divide 10 MeV
Overall dimensions weightbull Detector Oslash 54times200 mm 08 kgbull Moderator Oslash 245 mm 73 kg
NEUTRON-SEARCH BDKN-96Detector bull He-3 counter in polyethilene moderator
Measurement rangebull Dose rate H(10) for Pu-Be 01 μSvh divide 01 Svhbull Dose H(10) for Pu-Be 01 μSv divide 10 Sv
Energy range bull 0025 eV divide 14 MeV
Overall dimensions weightbull 295times142times100 mm 225 kg
BDKG-96M
BDMN-96
BDKN-96
SPC ldquoDozardquoRadiation monitoring equipment
60 61
bull No gas supply neededbull Clothing control detachable right hand detector bull Alpha detector optional connection bull Numeric and color (red green) indication of
control resultsbull LED sensor of hand-foot positioning for start of
measurementbull Automatic compensation of gamma background
and contamination of detectorbull Audible alarm signals of the excess of preset
thresholdsbull Measurement value indication min-1cm-2 or
Bqсm2
Reference standards Nuclear IEC 61098
RZB-05D HAND-FOOT-CLOTHING MONITOR
Physical characteristicsDetectors bull Gamma beta - GM countersbull Alpha - scintillatior ZnS(Ag)
Detecting nuclidesbull Alpha Pu-239 U-234 U-238bull Beta Sr-90+Y-90 F-18 Cs-137 Co-60 Tс-99 O-15
N-13 Sr-89 C-11 I-131 Na-22 Ru-106+Rh-106 Tl-204
bull Gamma Tc-99m I-123
Efficiencybull Alpha
Pu-239 40 U-234 25U-238 15
bull Beta Sr-90 +Y-90 40
Measurement range bull Alpha 1 divide 103 min-1cm-2 bull Beta 10 divide 103 min-1cm-2
bull Gamma 5103 divide 5106 min-1cm-2
Energy range bull Alpha 30 divide 80 MeV bull Beta 008 divide 35 MeV bull Gamma 005 divide 30 MeV
Operation temperature range bull Minus 10 divide +50 ordmС
Electrical characteristicsbull Power supply 220 V 50 Hz
Mechanical characteristicsOverall dimensions weight bull 740times750times1180 mm 45 kg
Versionsbull Withwithout alpha detectorbull Indication (min-1cm-2 ) or (Bqсm2)bull Detectors overall dimensions smbull Hand 178 х 235bull Foot 185 х 436
Whole body contamination monitor RZBA-04-04Mbull No gas supply neededbull Compensation for background gamma radiation
and contamination of detector unitsbull Individual threshold setting for each measure-
ment channelbull Visible and audible alarms ldquoCONTAMINATIONrdquo and
ldquoCLEANrdquo bull Indication of contaminated body parts on the
panel with image of the bodybull Optional remote alpha-detector
Physical characteristicsDetectors bull Beta - GM counters scintillatorsbull Alpha - scintillatior ZnS(Ag)
Measurement range bull Beta 5 divide 15000 min-1cm-2
bull Alpha 01 divide 10000 min-1cm-2
Energy range bull Beta 015 divide 25 MeV bull Alpha 40 divide 56 MeV
Operation temperature range bull +5 divide +50 ordmС
Electrical characteristicsPower supply bull 220 V 50 Hz
Interfaces bull RS-232bull RS-485
Mechanical characteristicsOverall dimensions weight bull 2650times940times930 mm 310 kg
Versionsbull Withwithout alpha detectorbull Indication (min-1cm-2 ) or (Bqсm2)
Reference standards Nuclear IEC 61098
RZBA-04-04MWHOLE BODY CONTAMINATION MONITOR
SPC ldquoDozardquoRadiation monitoring equipment
62 63
RZA-05DALPHA HAND-MONITOR
bull No gas supply needed bull Numeric and color (red green) indication of
control resultsbull LED sensor of hand- positioning for start of
measurementbull Audible alarm signals of the excess of preset
thresholdsbull Measurement value indication min-1cm-2 or
Bqсm2
Physical characteristicsDetectors alpha - scintillatior ZnS(Ag)
Efficiencybull Pu-239 20 bull U-234 14bull U-238 8
Measurement range bull 05 divide 105 min-1cm-2
Energy range bull 41 divide 90 MeV
Operation temperature range bull minus 10 divide +50 ordmС
Electrical characteristicsPower supply bull 220 V 50 Hz
Mechanical characteristicsOverall dimensions weight no more bull 740times1400times1450 mm 70 kg
Reference standards Nuclear IEC 61098
bull Simultaneous measurement of alphabeta activi-ties in the sample
bull Active shielding anti-coincidence background subtraction using GM counters
bull Lead shielding 30 mm
UMF-2000 LOW LEVEL ALPHA- BETA- COUNTER
Physical characteristicsDetectors bull Silicon specrometric detector 500 or 1000 mm2
Measurement range bull Alpha 001 divide 1000 Bq bull Beta 01 divide 3000 Bq
Energy range bull Alpha 35 divide 80 MeV bull Beta 005 divide 35 MeV
Electrical characteristicsPower supply bull 220 V 50 Hz
Interfaces bull RS-232bull USB
Mechanical characteristicsOverall dimensions weight bull 337times286times190 mm 22 kg
Versionsbull Detector area 500 mm2
bull Detector area 1000 mm2
UMF-2000 Detector area 1000 mm2
UMF-2000 Detector area 500 mm2
SpectraDec software for alpha-spectrometric measurements
SPC ldquoDozardquoRadiation monitoring equipment
64 65
DRK DOSE AREA PRODUCT METER
DRK-1bull Diagnostic reference level (DRL) of patients
determinationbull Suitable for all basic types of x-ray machines
Physical characteristicsDetector bull Plane-parallel ionization chamber
Measurement range bull 1 divide 104 cGycm2
Electrical characteristicsPower supply bull 220 V 50 Hz
DRK-1M-CTbull Measuring of dose length product
Physical characteristicsDetector bull Pencil Ionization Chamber
Measurement rangebull 05 divide 109 microGym
DRK-1Mbull Measuring of air kerma on sectional area of the
X-ray beam productbull Measuring of air kerma rate on area productbull Measuring of air kerma ratebull Measuring of air kerma
Physical characteristicsDetector bull Plane-parallel ionization chamber
Measurement rangebull 01 divide 109 microGym2
bull 06 divide 6104 microGym2cbull 30 divide 9105 microGycbull 30 divide 9991011 microGyReference standard IEC 60580 2003
bull Measurement of strontium-90 in the foodstuffs agricultural products etc
bull Measurement of gross beta activity in samplebull Self tests using built-in LED
ldquoPROGRESS-BETArdquo SCINTILLATION BETA SPECTROMETER
Physical characteristicsDetector bull Plastic scintillator Oslash70x10 mm
Sample bull Plate Oslash70 mmbull Weight up to 15 g
Energy range bull 02 divide 30 MeV
Minimum detectable activity of Sr-90 in a 10 g sample on a standard planchet Bqsamplebull In case of absence of K-40 in the sample 01 Bqbull In case the activity of K-40 till 5 Bqg 05 Bq
Electrical characteristics Interface bull USB
Mechanical characteristicsWeight bull No more 50 kg
Complete setBasic complete setbull Detector unit with plastic scintillator integrated
power supply amplifier ADC bull Lead shielding bull ldquoProgressrdquo software bull Сheck source for energetic calibration (Sr-90-Y-90) bull Planchet Oslash 70 mm (5 items) bull Sample dencification device bull Procedure manual for measurement of radio-
nuclidesrsquo activity using the scintillation beta spec-trometer ldquoProgressrdquo
Optional equipment and servicebull Personal computer and printer bull Calibrations for radionuclides not included in the
main library of radionuclides
Progress-Beta
Reference standards IEC 61562
SPC ldquoDozardquoRadiation monitoring equipment
66 67
bull Measurement of gamma activity in foodstuffs soil samples and others environmental objects
bull Identification of radionuclides in the sample bull Automatic correction for sample density bull Self-tests using built-in LED
ldquoPROGRESS-GAMMArdquoSCINTILLATION GAMMA SPECTROMETER
Physical characteristicsDetector bull NaI (Tl) Oslash63times63 mm
Validated measurement geometries bull Marinelli beakers (1 liter) Petri dishes (Oslash90 mm)
etc
Energy range bull 02 divide 30 MeV
Minimum detectable activity Bqsamplebull Cs-137 3 Bqbull Th-232 7 Bqbull Ra-226 8 Bq bull К-40 40 Bq
Electrical characteristics Interface bull USB
Mechanical characteristicsWeight bull No more 120 kg
Complete setBasic complete setbull Scintillation detector unit with NaI (Tl) detector
with integrated power supply amplifier and ADC bull Lead shielding 50 mm bull ldquoProgressrdquo software bull Сheck source for energy calibration (Cs-137 +
K-40)bull Marinelli beakers - 1 liter (5 items) bull Petri dishes Oslash 90 mm (5 items) bull Procedure manual for measurement of activity
of radionuclides using the scintillation gamma spectrometer ldquoProgressrdquo
Optional equipment and servicebull Kit for radon measurements including calibration
of ldquoIC-63rdquo geometry for counting the charcoal samples
bull Personal computer and printer bull Calibrations for user defined geometries bull Calibrations for radionuclides not included in the
main library of radionuclides
Progress-Gamma
Reference standards IEC 61563
ldquoPROGRESS-G(P)rdquoPORTABLE SCINTILLATION GAMMA SPECTROMETERbull Field measurements of gamma activity in environ-
mental objects without sampling (4π geometry)bull Laboratory measurement of gamma activity in
foodstuffs soil samples and others environmental objects
bull Identification of radionuclides in the sample bull Automatic correction for sample densitybull Tests using built-in LED
Physical charachteristicsDetector bull NaI (Tl) Oslash45times50 mmbull Lead shielding 20 mm
Validated measurement geometries bull Marinelli beakers (05 liter) Petri dishes (Oslash90 mm)
etc
Energy range bull 02 divide 30 MeV
Minimum detectable activity in 05-litre Marinelli beaker bull Cs-13710 Bqkgbull К-40100 Bqkgbull Ra-22618 Bqkg bull Th-23216 Bqkg
Minimum detectable activity in 30 min (4π geometry) bull Cs-137 2 Bqkgbull К-40 30 Bqkgbull Ra-226 4 Bqkg bull Th-232 3 Bqkg
Electrical characteristicsPower supply bull Rechargeable batterybull 220 V 50 Hz
Interface bull USB RS-232
Weight bull No more than 60 kg
Complete setBasic complete setbull Scinttillation detector unit with NaI(Tl) bull ldquoProgressrdquo softwarebull Сontrol unit ldquoSputnikrdquo for aquisition and analisys
of spectra with built-in memory for spectral databull Casebull Lead shielding (2 cm) for laboratory usebull 05-litre Marinelli beakers ndash 5 itemsbull Na-22 check sourcebull Power adapter BPS-01bull Operation manualbull Procedure manual for measurement of activity
of radionuclides using the scintillation gamma spectrometer ldquoProgressrdquo
Optional equipment and servicebull Kit for radon measurements with charcoalbull Built-in dose rate meterbull Additional memory (RAM) for storage of 64
spectrabull Additional power adapterbull Notebook and printer
Progress-Gamma
Reference standards IEC 61563
SPC ldquoDozardquoRadiation monitoring equipment
68 69
Physical characteristicsDetectorbull Scintillation detector ZnS (Oslash 60 mm)
Samplebull Thin sample - diameter up to 70 mm bull Preparation technique - electro-depositionbull Thick sample - diameter 70 mm weight
200300 mg bull Preparation technique - application of powders
(prepared by radiochemical concentration by water evaporation or by pounding of mineral samples) onto a planchet with the help of spirit
Energy rangebull 15 divide 8 MeV
Minimum detectable activitybull Thin samples no more than 910-3 Bqsamplebull Thick samples no more than 180 Bqkg
Mechanical characteristicsOverall dimensions weightbull 195times120times210 mm 34 kg
Complete setBasic complete setbull Alpha radiometer ldquoProgress-ARrdquobull Check source (uranium isotopes)
Set of accessoriesbull Procedure manual for measurements of radi-
oactivity using scintillation alpha radiometer ldquoProgress-ARrdquo
bull ldquoProgressrdquo software
ldquoProgress-ARrdquo
bull Measurement of gross activity of alpha emitting radionuclides in thin samples
bull Measurement of gross activity of alpha emitting radionuclides in thick samples
bull Measurement of activity deposited on aerosol filters
ldquoPROGRESS-ARrdquoALPHA RADIOMETER
Several fixed positions of the detector enable to perform measurements in various geometries and to estimate the content ofbull Cs-137 in the whole bodybull I-131 in thyroidbull Co-60 Cs-137 Mn-54 Cr-51 in lungsbull Database for storage of measurement data and
resultsbull Uncertainty calculations based on measurement
databull Self tests using built-in LED
ldquoPROGRESSrdquo WHOLE BODY COUNTER
Physical characteristicsDetectorbull scintillation detector NaI (Tl) Oslash63times63 mm
Energy rangebull 02 divide 28 MeV
Minimum detectable activitybull By Cs-137 in the whole body - 1200 Bqbull By I-131 in thyroid - 100 Bqbull By Co-60 Cs-137 Mn-54 Cr-51 in lungs - 200 Bq
Mechanical characteristicsWeight bull No more than 120 kg
Complete setBasic complete setbull Collimator with rotator and holderbull Detector with incorporated ADCbull Patient chair and table for collimatorbull Check source Na-22bull Procedure manual for lifetime measurement of
gamma-emitting radionuclidesrsquo activity in human body using the gamma-spectrometer of human radiation ldquoProgressrdquo
bull laquoProgressraquo software
Optional equipment and servicebull Program of internal radiation committed internal
radiation effective dose calculation by the stand-ard model
bull Background phantombull Personal computer and printer
Collimator with rotator and holder
SPC ldquoDozardquoRadiation monitoring equipment
70 71
bull Categorization of wastes for the purpose of fur-ther processing including wastes with unknown radionuclide composition
bull Measurements during the incoming waste inspec-tion (accepting for storage disposal)
bull Certification of unconditioned and conditioned wastes in closed containers without opening them (at nuclear plants or at facilities providing collection storage transportation conditioning processing temporal storage and final disposal of radioactive waste)
bull Activity measurement of extended objects in situ without opening the equipment
bull Activity measurement of extended objects after opening (for example assessment of tubes used for oil transportation)
MKG-01D ldquoSADOVNIKrdquoSPECTROMETRY SYSTEM
Physical charachteristicsDetectorbull Detector unit GEM (GMX) with HPGe detector and
multi-positioning cryostat CFG-PMOD4-7 with 7 litre Dewar
bull Dose rate probe BDMG-200
Energy range bull With GEM detector 004 divide 30 MeVbull With GMX detector 0005 divide 15 MeVbull Dose rate probe BDMG-200 ndash 005 divide 30 MeV
Measurement rangebull 110-7 divide 10 Svhbull Relative efficiency of detection (in photopeak) at
13325 MeV (Co-60) 10 divide 150
Electrical characteristicsPower supplybull 220 V 50 Hz
Interfacebull USB
Complete setBasic complete setbull Spectrometric detector unit GEM (GMX) with
HPGe detector and multi-positioning cryostat with 7 litre Dewar
bull Portable digital multichannel analyzer DigiDARTbull Dose rate probe BDMG-200bull Autonomous power supply unit with built-in
batterybull Industrial computer keyboardbull Laser range-finderbull Thermographic printerbull Web-camerabull Device equipped with stepper motor for position-
ing of the spectrometric detectorbull Calibration device with reference sources
(Am-241 Co-60 Ba-133 Eu-152) for energy calibration
bull Removable collimators with end capbull Measurement proceduresbull ldquoClasterrdquo software
bull Measurement of gross alpha activity of alpha-emitting radionuclides
bull Measurement of alpha-emitting radionuclides activity in thin-layer samples meeting alpha-spectrometry requirements
Physical characteristicsDetectorbull Silicon ion-implanted 450 mm2
bull Easy to decontaminate thin windowbull dead layer less than 015 μmbull Background count rate in the range 3 divide 9 MeVbull No more than 09 h-1cm-2 for 450 mm2 detector
Energy rangebull 2 divide 9 MeVbull Lower limit of measurement range (minimum
detectable activity) 01 Bqbull Background count rate no more than 100 counts
in 24 hours
Electrical characteristics Power supplybull 220 V 50 Hz
Interfacebull USB
Complete setBasic complete setbull Detector unit with vacuum measuring chamber
and vacuum control systembull Low noise vacuum pump (type 2FY-05B or
equivalent)bull Check sourcebull ldquoProgressrdquo softwarebull Vacuum tube
MKS-01A ldquoMULTIRAD-ASrdquoALPHA SPECTROMETER
SPC ldquoDozardquoRadiation monitoring equipment
72 73
UCRV-2AIRFLOW MONITOR
bull Monitor of the air flow through filter of centralized multichannel sampling system
bull Radiation monitoring system (RMS) integration for internal exposures determination
bull Volume and flow rate measurements of the air that have passed through a analytical filter
bull Bar-code for filter identificationbull Operation as either standalone unit or as a part of
the RMS
Physical characteristicsMeasurement range of air volume bull 001 divide 9999 m3
Operation temperature range bull minus 20 divide +50 ordmС
Electrical characteristicsPower supply bull 220 V 50 Hz
Interface bull RS-485
PVP-06PORTABLE AIR SAMPLER
Air Sampler PVP-06 is indispensable for monitoring the radiation situation where the concentration of radioactive aerosols in the air does not require a sta-tionary sampling equipment Sampling head PVP-06 provides easy change of filters and cartridges
Purposebull To monitor the concentration of radioactive aero-
sols in the air sites
Controlled aerosolsbull Alpha- and beta-active aerosolsbull Daughter products of decay of radon and thoronbull Iodine isotopes
Physical characteristicsTypes of filtersbull Aerosol AFA-RSP-20bull Iodine AFA SI-20
Flow rate bull 33∙10-4 ndash 233∙10-4 m3s (20 divide 140 l min)
Electrical characteristicsPower supply bull 220 V50 Hzbull The vehicle power supply 108 divide 145 Vbull Internal battery
Minimal working time on internal battery to recharge bull 8 hours
Power consumption (at a flow rate of 100 lmin) bull 40 VA
Environment characteristicsOperating temperature bull minus 10 divide +40 deg C
Maximum humidity bull 90
Pressure bull 860 to 1060 hPA
Noise generated by the pump bull lt 55 dBA at 1 m
Mechanical characteristicsDimensions weight bull 241 times 108 times 160 mm 28 kg
Case material bull Plastic
Complete setbull Air sampler PVP-06bull AC power adapterbull Filters AFA-RSP-20 - 100 pcsbull Packaging for filters - 40 pcsbull Casebull Operation manualbull Calibration certificate
Optional equimpient bull Kit for sampling sorption columns of activated
carbon Ř head of sorption columns with protective
covers Ř activated charcoal SKT-3 - 1 pkg (02 L) Ř charocoal samples SC-13 - 8 pcs
bull Car charger bull Tipod bull Shoulder strapbull Calibration stand bull Filters AFA SI-20 - 100 pcs
Consumablesbull Aerosol filters AFA RSP-20bull Iodine filters AFA SI-20
SPC ldquoDozardquoRadiation monitoring equipment
74 75
Calibration of gamma dose and dose rate meters
Calibration ofbull Ambient equivalent dose H(10) meters (Sv Svh)bull Personal equivalent dose Hp(10) meters (Sv Svh)bull Exposure dose X meters (R Rh)bull Two sources in irradiator bull Select source and collimator opening using
tumbler
UPG-P DESKTOP GAMMA BEAM IRRADIATOR
Physical characteristicsRange of reproduced dose rate bull 05 μSvh divide 10 mSvh (50 μRh divide 100 mRh)
Sources activities bull 6times106 6times108 Bq (02 20 mCi) Cs-137
Overall dimensions bull 1250times400times300 mm
Irradiator weight bull Not more than 37 kg
Calibration bench weight bull Not more than 15 kg
Reference standards IEC 60846 IEC 61526
Physical characteristicsDetectorbull Silicon
Measurement range EEC measurement bull Measurement range of radon EEC
10 divide 10bull106 Bqbullm-3
bull Measurement range of thoron EEC 05 divide 10bull104 Bqbullm-3
bull Air flow through the filter 100plusmn05 lmin
Concentration measurementbull Measurement range of radon-222 concentration
in air 10 divide 20bull106 cpsbull Measurement range of 216Po(ThA)
1bull10-3 divide 1bull102 cpsbull Air sampler flow rate
10plusmn02 lminbull Measurement range of radon-222 concentration
in water samples 6 divide 800 Bqbullkg-1
bull Measurement range of radon-222 flux from soil surface 20 divide 103 mBqsbullm2
bull Measurement range of radon-222 concentration with preliminary sampling of air using air sam-plers 20 divide 107 Bqbullm-3
bull Measurement range of radon-222 concentration in samples of soil air 103 divide 106 Bqbullm-3
Operation temperature range bull 1 divide 35 ordmC
Electrical characteristicsPower supply bull 80 VA
Mechanical characteristicsOverall dimensions weight bull 220times200times165 mm 36 kg
ldquoALPHARAD PLUSrdquoRADON THORON amp THEIR PROGENY MONITORbull Measurement of radon and thoron concentration
and effective equivalent concentration (EEC)bull In the airbull In the indoor air of residential public and industri-
al buildings and structuresbull Measurement of radon in drinking water sourcesbull Measurements of radon flux from the soil surface
at land plots allocated for construction of houses public buildings and industrial facilities
bull Measurements of radon concentration in soil air
Reference standards IEC 61577
SPC ldquoDozardquoRadiation monitoring equipment
76 77
UKPN-2M-D NEUTRON BEAM IRRADIATOR
Reference standards IEC 61005 61322
Calibration of neutron dose and dose rate meters
Calibration ofbull Ambient equivalent dose H(10) meters (Sv Svh)bull Personal equivalent dose Hp(10) meters (Sv Svh)bull Flux density of neutrons (cm-2∙s-1)bull Transfer container for temporary storage of
sources bull Red light signal of source working position
Physical carachteristicsRange of reproduced dose ratebull 20 divide 800 μSvh
Range of reproduced flux densitiesbull 10 divide 400 cm-2∙s-1
Type of a source in use bull Pu-Be
Activity of a source in usebull 24х1011 Bq (with density of 107 s-1)
Overall dimensions weight no morebull 3000x750x2000 mm 300 kg
Required room dimensionsbull not less than 7x3x3 m
Electrical characteristicsPower supply bull 220 V 50 Hz
Calibration of gamma dose and dose rate meters
Calibration ofbull Ambient equivalent dose H(10) meters (Sv Svh)bull Personal equivalent dose Hp(10) meters (Sv Svh)bull Exposure dose X meters (R Rh)bull Four sources in irradiator bull Select source and move to working position
return to storage position using special rodbull Transfer container for temporary storage of
sources bull Red light signal of source working position
UPGD-2M-DGAMMA BEAM IRRADIATOR
Physical characteristicsRange of reproduced dose rate bull 05 μSvh divide 50 mSvh (50 μRh divide 5 Rh)
Maximum activity of source bull 2times1011 Bq (50 Ci) Cs-137
Overall dimensionsbull Irradiator 800times500times500 mmbull Guide rails length 30 mbull Height 16 mbull Weight not more than 700 kgbull Required room dimensions not less than 7x3x3 m
Electrical characteristicsPower supply bull 220 V 50 Hz
UPGD-2M-D
Reference standards IEC 60846 IEC 61526 IEC 61066
SPC ldquoDozardquo
78 79
Contents
MEASURING UNITS
DBG-S11D wide range gamma area monitor 40
UDKS-100 gamma and X-ray area monitor 41
UDMN-100 neutron area monitor 41
ALARM UNITS
BAS-2 ldquoMICROrdquo external visual alarm 42
BZS-2 ldquoMicrordquo external audible alarm 42
Illuminated warning signs 43
ldquoImpulsrdquo external display unit 43
UIM-3D area monitor count rate meter 44
DKG-05D personal gamma dosimeter 46
DVS-02D gamma-neutron personal electronic dosimeter 47
DVGI-8D new pen-type personal ionization chamber dosimeters 48
DKG-02U ldquoARBITERrdquo wide range gamma-dosimeter 49
DKG-07D ldquoDROZDrdquo gamma-dosimeter 50
MKS-15D ldquoSNEGIRrdquo multi ndash purpose radiation survey meter 51
SRPS-05D gamma monitor 52
DOZA-TLD multipurpose TLD system 53
DKS-96 universal radiation survey meter 54
EXTERNAL PROBES ALPHA
Alpha BDZA-96 55
Alpha BDZA-96B 55
Alpha BDZA-96M 55
Alpha BDZA-96S 55
Alpha BDZA-96T 55
EXTERNAL PROBES BETA
Beta BDZB-96 56
Beta BDZB-99 56
Beta BDZB-96B 56
Beta BDZB-96S 56
EXTERNAL PROBES GAMMA
Gamma BDKS-96B 57
Gamma and beta BDKS-96S 57
Gamma BDMG-96 57
EXTERNAL PROBES GAMMA
Gamma-search BDVG-96 58
Gamma-search BDPG-96 58
ContentsRadiation monitoring systemldquoPELIKANrdquo Radiation monitoring system (RMS) 6
BDMG-101 high range gamma area monitor 10
DBG-S11D wide range gamma area monitor 11
BDRG-52 high range gamma area monitor for accident and post-accident conditions 12
UDGP-01 Liquid technological environments monitor 13
UDMN-100 neutron area monitor 14
UDKG-100 Wel Liquid gamma monitor 14
BOP-1M data processing and transmission unit 15
UDA-1AB particulate monitor 16
UDG-1B noble gas monitor 17
UDG-03D noble gas monitor 18
UDI-1B iodine monitor 19
UDGB-01 noble gasesH-3C-14 monitor 20
UDGP-01 steam generator leakage monitor 21
UPPVM air flow parameters monitor 22
ldquoIMPULSrdquo external display unit 23
BI-2 remote display amp alarm unit 24
BASBAS-1s external alarm 25
SKGAV stack monitor 26
RMS software 28
RMS workstation ndash operator console 29
Configurator software 29
RM RACK radiation monitoring rack 30
SRKS-01D criticality accident alarm system 32
ldquoATLANT-Mrdquo environmental radiation monitoring system 34
ldquoBREEZErdquo high-volume air sampler 35
ldquoGAMMA-SENSORrdquo gamma-survey system 36
Radiation monitoring equipmentAREA MONITOR ldquoFREGATrdquo 38
BPI-1D local display unit 39
80
Gamma-search BDPG-96M 58
Gamma BDKG-96 stainless steel casing for geologic applications well logging 59
EXTERNAL PROBES NEUTRON
Neutron BDMN-96 59
Neutron-search BDKN-96 59
RZB-05D Hand-foot-clothing monitor 60
RZBA-04-04M whole body contamination monitor 61
RZA-05D alpha hand-monitor 62
UMF-2000 low level alpha- beta- counter 63
DRK dose area product meter 64
ldquoPROGRESS-BETArdquo scintillation beta spectrometer 65
ldquoPROGRESS-GAMMArdquo scintillation gamma spectrometer 66
ldquoPROGRESS-G(P)rdquo portable scintillation gamma spectrometer 67
ldquoPROGRESS-ARrdquo alpha radiometer 68
ldquoPROGRESSrdquo whole body counter 69
MKG-01D ldquoSADOVNIKrdquo spectrometry system 70
MKS-01A ldquoMULTIRAD-ASrdquo alpha spectrometer 71
UCRV-2 airflow monitor 72
PVP-06 portable air sampler 73
ldquoALPHARAD PLUSrdquo radon thoron amp their progeny monitor 74
UPG-P desktop gamma beam irradiator 75
UPGD-2M-D gamma beam irradiator 76
UKPN-2M-D neutron beam irradiator 77
Radiation monitoring system SPC ldquoDozardquo
20 21
Continuous automatic monitoring of steam genera-tor primary to secondary leakagebull On line gamma spectrometrybull N-16 monitoringbull Performance self-test by means of Am-241 check
source implanted into the detectorbull Audible and visual alarm signals of the excess of
preset thresholds
Physical characteristics
UDGP-01 STEAM GENERATOR LEAKAGE MONITOR
bull detector ndash scintillator CsI Oslash 40х100 mm
Measurement range bull High energy gamma-activity (N-16)
15bull103 divide 20bull108 Bqm3
bull General gamma-activity 10bull104 divide 20bull108 Bqm3
Energy range bull General gamma 005 divide 15 MeV bull in integral spectral band of energy
5000 divide 7200 keV bull temperature range minus 10 divide +80 ordmС
BOP-1SP
Electrical characteristicsbull Power supply 85 divide 260 V 47 divide 440 Hzbull Interfaces RS-232 RS-485 Ethernetbull programmable relay output (SPDT relay)
Mechanical characteristicsbull Protection index IP 65bull Paint decontaminable
Overall dimensions weight bull Detector unit Oslash 60x360 mm17 kgbull Data processing and transmission unit BOP-1sp
280x220x114mm 43 kgbull Collimator Oslash 350x455 mm 150 kg
Alarmbull Sound alarm 80 divide 100 dBA at distance 1 mbull Visual alarm green yellow redbull Connection of the external alarm unit of ldquoBASrdquo
type
Reference standards Nuclear IEC 61453 EMC IEC 61010 IEC 61000-6-2 Seismic IEC 60980Reference standards Nuclear IEC 60761 IEC 60710 IEC 60951-2 EMC IEC 61010 IEC 61000-6-2 Seismic IEC 60980
Ionization chambe 10 liters
UDGB-01T1
Physical characteristicsbull Detectors - stainless steel ionization chambersbull Air flow rate 10 divide 100 lminbull Operation temperature range minus 10 divide +50 ordmС
Volumes of ionization chambers bull UDGB-01T UDGB - 01T1 100 litersbull UDGB-01T2 01 liter
Measurement range (Kr-85) bull UDGB-01T UDGB-01T1 10104 divide 50109 Bqm3
bull UDGB-01T2 109 divide 501014 Bqm3
Measurement range (H-3) bull UDGB-01T UDGB-01T1 50104 divide 50109 Bqm3
bull UDGB-01T2 50109 divide 501014 Bqm3
Electrical characteristicsbull Power supply 85 divide 260 V 47 divide 440 Hzbull Interfaces RS-232 2timesRS-485 Ethernetbull Programmable relay output (SPDT relay)bull Analog output 4-20 mA (optional)
Mechanical characteristicsbull Protection index IP 23bull Paint decontaminable
Continuous automatic monitoring of the beta-emitting radioactive gases including tritium and carbon-14 concentration in the air at working places and in ventilation ducts and stacksbull Audible and visual alarm signals of the excess of
preset thresholds bull Monitoring of the noble gase activity in gaseous
effluents and ventilation air for accident and post-accident conditions
Overall dimensions weight bull UDGB-01T 381times343times716 mm 30 kgbull UDGB-01T1 260times320times175 mm 125 kgbull Ionization chamber 100 liters Oslash 250times600 mm
6 kgbull UDGB - 01T2 381times343times716 mm 27 kg
Alarmbull Sound alarm 80 divide 100 dBA at distance 1 mbull Visual alarm green yellow redbull Connection of the external alarm unit ldquoBASrdquo type
Versionsbull UDGB-01T - with built-in ionization chamber
100 litersbull UDGB-01T2 - with built-in ionization chamber
01 literbull UDGB-01T1 - with remote ionization chamber
100 liters
UDGB-01NOBLE GASESH-3C-14 MONITOR
Radiation monitoring system SPC ldquoDozardquo
22 23
Physical characteristicsLength of communication cablebull up to 1200 m
Character height bull ldquoImpuls-910-Rrdquo 100 mmbull ldquoImpuls-915-D4Srdquo 150 mmbull ldquoImpuls-927-D4Srdquo 270 mm
Operating temperature rangebull ldquoImpuls-910-Rrdquo 0 divide +50 ordmCbull ldquoImpuls-915-D4Srdquo ldquo-927-D4Srdquo minus 40 divide +50 ordmC
Electrical characteristicsbull Power supply 220 V 50 Hz
Mechanical characteristicsProtection index bull ldquoImpuls-910-R IP 44bull ldquoImpuls -915-D4Srdquo ldquo-927-D4Srdquo IP 65
Overall dimensions weight bull ldquoImpuls-910-Rrdquo 400times160times60 mm 3 kgbull ldquoImpuls -915-D4Srdquo 815times250times80 mm 5 kgbull ldquoImpuls -927-D4Srdquo 1250times330times80 mm 5 kg
ldquoIMPULSrdquoEXTERNAL DISPLAY UNIT
Display of data received from monitors of RMS
External display unit ldquoImpuls-910-Rrdquo
Reference standards EMC IEC 61010 IEC 61000-6-2 Seismic IEC 60980
Continuous monitoring of the flow rate temperature and humidity of the gas flowbull Definition of air volume flow rate in stacks taking
into account temperature and humidity of the air
UPPVM AIR FLOW PARAMETERS MONITOR
Physical characteristicsMeasurement range bull air flow velocity 1 divide 20 msbull air temperature 0 divide +80 ordmСbull air humidity 10 divide 95
Electrical characteristicsbull Power supply 220 V 50 Hz bull Interfaces RS-232 Ethernet
Mechanical characteristicsProtection index bull BSPP-1st BSPP-1tv BOP-1s IP 65bull PP-st IPTV IP 54bull Paint decontaminable
Overall dimensions weight bull air velocity probe PP-st 60times38times136 mm 015 kgbull Interface block BSPP-1st 125times155times73 mm 07 kgbull air temperature and relative humidity probe
IPTV-056-A 333times100times60 mm 07 kgbull Interface block BSPP-1tv 125times155times73 mm 07 kgbull Data processing and transmission unit BOP-1s
280x233x111 mm 8 kg
Reference standards Nuclear ISO 2889 EMC IEC 61010 IEC 61000-6-2 Seismic IEC 60980
BOP-1S
Radiation monitoring system SPC ldquoDozardquo
24 25
BASBAS-1S EXTERNAL ALARM
Generation of audible and visual signals of the excess of preset thresholds RMS monitorsbull Audible alarm 80 divide 100 dBA at distance 1 mbull Visual alarm green yellow red
Distance from RMS monitorbull BAS up to 20 mbull BAS-1s up to 1200 m
Power supply bull 220 V 50 Hz
Overall dimensions weight bull BAS 145times108times460 mm 18 kg bull BAS-1s 166times109times466 mm 18 kg
Reference standards EMC IEC 61010 IEC 61000-6-2 Seismic IEC 60980
Physical characteristicsLength of communication cablebull up to 1200 m
Displayed page size bull 4 lines of 20 characters
Volume of loaded information bull 10 pages
Change of pagesbull programmed or by pressing a button
Operating temperature rangebull minus 40 divide +50 ordmC
Electrical characteristicsbull Power supply 9 divide 18 VDCbull Interfaces RS-485
Mechanical characteristicsbull Protection index IP 65bull Overall dimensions weight 222times164times73 mm
40 kg
BI-2 REMOTE DISPLAY amp ALARM UNIT
bull Display of data received from monitors of RMSbull Audible and visual alarms on exceeding preset
thresholds of the RMS equipment bull Individual threshold setting for each measure-
ment channelbull Audible alarm 80 divide 100 dB at a distance of 1 m bull Visual alarm red yellow green
Reference standards EMC IEC 61010 IEC 61000-6-2 Seismic IEC 60980
Radiation monitoring system SPC ldquoDozardquo
2726
Electrical characteristicsbull Power supply 220 V 50 Hz bull Interfaces RS-232 RS-485 Ethernetbull programmable relay output (SPDT relay)
Alarmbull Sound alarm 80 divide 100 dBA at distance 1 mbull Visual alarm green yellow redbull Connection of the external alarm unit ldquoBASrdquo type
Related monitors and equipmentsbull UDA-1AB particulate monitorbull UDG-1B noble gas monitorbull UDI-1B iodine monitorbull UPPVM air flow parameters monitorbull Sampling and sample separation rack
Air flow parameters monitor rack
Reference standards Nuclear IEC 60761 IEC 61171 IEC 61172 IEC 62302 ISO 2889 EMC IEC 61010 IEC 61000-6-2 Seismic IEC 60980
Sampling and sample separation rack
Continuous monitoring of radioactivity in gaseous effluentsbull Automatic monitoring of the alpha- and beta-
radioactive aerosol noble gas and radioiodine concentrations in the air in ventilation ducts and stacks
bull Monitoring of the flow rate temperature and humidity of the gas flow
bull Separation of gaseous effluent into targeted fractions by means of a two-stage filter
bull Reversion of gas after analysis to the ventilation system
Physical characteristics
Particulate (UDA-1AB)bull Silicon specrometric detectors (2 pcs for measure-
ment and for gamma-background compensation) bull Filter tape types LFAS FSLWbull Tape consumption (when continuous operation)
10 m50 days
Measurement range bull Alpha 10-2 divide 2105 Bqm3 bull Beta 10-1 divide 106 Bqm3
Energy range bull Alpha 30 divide 90 MeV bull Beta 005 divide 30 MeV
Noble gas (UDG-1B)bull silicon detectors (2 pcs for measurement and for
gamma-background compensation)
Measurement range bull 104 divide 6109 Bqm3
Energy range bull 008 divide 30 MeV
Iodine (UDI-1B)bull scintillation detectors CsI(Tl) (2 pcs for measure-
ment and for background compensation)
SKGAV STACK MONITOR
Particulate noble gas and iodine monitors rack
Measurement range bull 37 divide 37105 Bqm3
Energy range bull 015 divide 30 MeV
Air flow parameters (UPPVM)Measurement range bull air flow velocity 1 divide 20 msbull air temperature 0 divide +80 ordmСbull air humidity 10 divide 95
Radiation monitoring system SPC ldquoDozardquo
28 29
CONFIGURATOR SOFTWAREMaintenance and set-up softwarebull Set-up and verify RMS monitorsbull Control testing adjustment and repair of RMS
monitorsbull Monitors measurement results archive receive
and View bull Communication through RS-232
RMS WORKSTATION ndash OPERATOR CONSOLEOrganization of interaction of the RMS Server and Monitors
Single monitor console includes vandal-proof key-board amp UPS
Reference standard IEC 61559-1 IEC 61559-2
RMS SOFTWAREData acquisition storing and visual representation RMS monitors measurement resultsbull Ethernet IEEE 8023 networkbull Clientserver architecturebull TCPIP protocolbull Oracle based Data Basebull Supremal by means InSat MasterSCADA
Radiation monitoring system SPC ldquoDozardquo
30 31
Delivery setComposition and modification depend on the tasks to be solved using the RM Rack
The rack which is an integral part of RM Rack accommodatesbull Monitors UDA-1AB UDG-1B UDG-03D UDI-1B
UDGB-01Tbull DBG-S11D Wide range gamma area monitor
BDMG-101 High range gamma area monitor UDMN-100 Neutron area monitor BDRG-52R High range gamma area monitor
bull BI-2 Remote display amp alarm unitbull Pump unit BN-01bull Data processing and transmission unit BOP-1Mbull External alarm BAS or BAS-1sbull Equipment of sampling line (flow meters ball
valves filter holder piping solenoid valve)bull Switchboard (intended for switching of all equip-
ment and transfer of data to the upper level via the unified communication channel)
RM RACK RADIATION MONITORING RACK
The radiation monitoring rack (RM Rack) is designed for continuous monitoring of radiation parameters in premises and technological systems at nuclear facil-ities RM Rack can be used as a structural element of the lower-level of RMS at nuclear power plants and other nuclear facilities that involved in obtaining processing use and storage of radioactive materials
FeaturesContinuous automatic monitoring of the alpha- and beta- radioactive aerosol beta-emitting radioactive gases and radioiodine concentrations in the working air and in the air in stacks and others radiation parameters in the facilities
The stand providesbull Primary processing storage and transmission of
measured and related data into the information channel based on the Ethernet IEEE 8023 inter-face (TCPIP protocol)
bull Transfer of required data to the location where the equipment is installed via technological channels based on RS-232 interface
bull Generation of audible and visual warning alarm signals when the preset thresholds are exceeded
bull Display of received data on the LCD
Radiation monitoring system SPC ldquoDozardquo
32 33Reference standards IEC 60860 ANSIANS-83 ISO 7753
Purposebull Detection and recording of criticality accident
(CA) by measuring the absorbed dose rate of gamma-neutron radiation in the premises of monitored object its comparison with a threshold value and generation of audible and visual signals
bull Automatic collection processing storage and display of measurement data and related infor-mation as visual and graphical representation for operators of nuclear safety service
Functions of the systembull Detection and recording of CA events by con-
tinuous measurement of absorbed dose rate of gamma radiation comparison of measured values with preset thresholds generation of signals to activate the alarm
bull Activation of audible visual alarmbull In the event of CA turning on warning signals
ldquoDO NOT ENTERrdquo at illuminated information pan-els placed at the entrances to the controlled area
Featuresbull Data can be transferred to external data commu-
nication channel using RS-485 interface (DiBus data exchange protocol)
bull Automatic self-testing of detection units BR-04D with display of information about the type of fault
bull Possibility for connecting additional a detection and alarm units
bull Ability to function in general regardless of the functioning of components within the agreed scope of nuclear safety tasks
bull Radiation hardness up to 100 Gy
SRKS-01DCRITICALITY ACCIDENT ALARM SYSTEM
Features of softwarebull Collection of information via RS-485 network
displaying it on the PC monitor transmission to remote users archiving and storage
bull Status monitoring and display of values measured by BR-04D and DBG-S11D in locations as per layout of premises
bull Access to archived data with possibility to gener-ate reports for periods determined by operator
bull Maintenance and archiving of a log of dosimetric measurements data and events along with their time stamps
bull Possibility to transfer data to external users via Ethernet network for integrating of CA into higher level systems
Basic complete setLower level bull Control unit with power supplybull BR-04D detection unitsbull BZS-01D audible alarm unitsbull BSS-01D visual alarm unitsbull SIT-01D illuminated warning signsbull PBZ panels for muting audible alarmbull Network communication module
Additional lower layer devicesbull DBG-S11D wide range gamma area monitor
Upper layer bull CDP central display panelbull Service workstation
RS-485
RS-485
RS-4
85
Audible alarm units BZS-01D
Illuminated warning signs SIT-01D
Detection units BR-04D
Network communication
moduleDBG-S11D wide range gamma area monitor
Panels for muting audible alarm
Control unit with power supply
Visual alarm units BSS-01D
RS-485
RS-485
RS-4
85
Audible alarm units BZS-01D
Illuminated warning signs SIT-01D
Detection units BR-04D
Network communication
moduleDBG-S11D wide range gamma area monitor
Panels for muting audible alarm
Control unit with pow-er supply
Visual alarm units BSS-01D
RS-485
RS-4
85
Audible alarm units BZS-01D
Illuminated warning signs SIT-01D
Detection units BR-04D
Network communication
moduleDBG-S11D wide range gamma area monitor
Panels for muting audible alarm
Control unit with power supply
Visual alarm units BSS-01D
RS-485
RS-485
RS-4
85
Audible alarm units BZS-01D
Illuminated warning signs SIT-01D
Detection units BR-04D
Network communication
moduleDBG-S11D wide range gamma area monitor
Panels for muting audible alarm
Control unit with power supply
Visual alarm units BSS-01D
Ethernet
Central display panel Service workstation
RS-485
RS-485
RS-4
85
BZS-01D audible alarm units
SIT-01D illuminated warning signs
BR-04D detection units
Network communication
moduleDBG-S11D wide range gamma area monitor
PBZ panels for muting audible alarm
Control unit with power supply
BSS-01D visual alarm units
Radiation monitoring system SPC ldquoDozardquo
34 35
ldquoBREEZErdquoHIGH-VOLUME AIR SAMPLER
Physical characteristicsbull Measurement range of air flow rate
250 divide 1200 m3hbull Continuous operation time not less than 24 h
Filter materialsbull High-purity glass fiberbull Pure quartz or cellulosebull Filter fabric FPP-15-15
Electrical characteristicsPower supply bull 220380 V 50 Hz
Interfaces bull RS-485bull Ethernetbull GSMGPRS (option)
Environmental characteristicsTemperature range bull minus 40 divide + 40 ordmC
Relative humidity limit at 35 ordmC bull 95
Atmospheric pressure range bull 840 divide 1067 kPa
Versionsbull Standalone unit bull Part of Environmental Radiation Monitoring
System (ERMS)
Type of detection unitsbull Beta block BDZB-100Lbull DBG-S11D wide range gamma area monitorbull Scintillation spectrometric block
The motor of Air Sampler is controlled by an electronic flow sensor that detects changes in the operators pre-set flow rate caused by changes in temperature barometric pressure and pressure drop due to dust loading on filter media It compensates for these changes by adjusting the motor speed to maintain the pre-set flow ratebull Measurement of parameters of ionizing radiation bull Standalone mode of operation or as the part
of Environmental Radiation Monitoring System (ERMS)
Purposebull Environmental Radiation Monitoring System
(ERMS) in the control and buffer areas of the radia-tion and nuclear facilities
Referencesbull Since the year 2000 the system is successfully
operating the ERMSs at 8 Russian nuclear power plants (about 180 monitoring stations)
bull Since the year 2005 the ERMS is operating in the Moscow (about 40 monitoring stations)
bull Since the year 2005 the regional ERMS is under operation in several Russian Federation regions
Basic complete setMonitoring stations bull Data processing and transmission unit BOP-1TA bull Gamma area monitor DBG-S11D
Central data processing station (CDPS)bull Data processing and transmission unit BOP-1TAbull Server
By requestbull Emergency Response and Crisis Management
Centers for enterprisesbull Regional Emergency Response and Crisis Manage-
ment Centersbull rdquoBreezerdquo High-Volume Air Samplerbull Mobile lab with gamma-survey system rdquoGammandash
sensorrdquo
ldquoATLANT-MrdquoENVIRONMENTAL RADIATION MONITORING SYSTEM
Monitoring system for the continuous radiation monitoring of territories and facilities with the data transmission GSMGPRS network
Data transmission bull GSMGPRS
Power supply bull 220 V 50 Hz
Continuous autonomous operation (at 20 ordmC)bull From built-in battery not less than 5 hoursbull From external battery not less than 24 hours
Operation temperature bull Minus 40 divide +50 ordmC
Operation humidity bull Up to 98
Protection bull IP65
Reference standards Nuclear IEC 61017-11991 IEC 61017-21994
36
Radiation Monitoring Equipment
bull Localization of radioactive contaminationsbull Database with dose rate contaminations
spectra measurement date amp time coordi-nates
bull Work as part of mobile laboratory or as part of Environmental Radiation Monitoring System with real-time data transfer
Physical characteristicsDetector bull Scintillation NaI (Tl) GM counters
Measurement rangebull 01 ndash 107 μSvh
Energy range bull 005 ndash 3 MeV
Operation temperature range bull minus 10 divide +50 ordmС
Electrical characteristics bull Power supply 220 V 50 Hz
ldquoGAMMAndashSENSORrdquoGAMMA-SURVEY SYSTEM
SPC ldquoDozardquoRadiation monitoring equipment
38 39
AREA MONITOR ldquoFREGATrdquoArea Monitor ldquoFregatrdquo is designed for building rela-tively simple and inexpensive radiation monitoring systems at such facilities as radionuclide sources storage areas isotope products warehouses nuclear medicine departments PET centers calibration laboratories where sources of ionizing radiation are used etc
Small scale automated radiation monitoring systems built with ldquoFregatrdquo components featuring audible and visual alarms are matched suitable to meet the regulatory radiation safety requirements
Area monitor ldquoFregatrdquo requires virtually no adjust-ment it is simple and convenient for installation and operation
BPI-1D LOCAL DISPLAY UNIT
Display of monitored parameters values received from external measuring devices
Purposebull Processing and display of values of monitored
parameters on information panel bull Comparison of values of monitored parameters
with thresholdsbull Transfer of monitored parametersrsquo values to
networkbull Generation of alarm in case of exceeding of preset
thresholds including external alarm devices
FeaturesTesting the unit and connected devicesbull Visually on the panelbull Using adjustment software when connected to
PC via USB
Automatic self-testing
The panel displays the following informationbull Diagnostic information about the status of con-
nected devicesbull Current date and timebull Values of measured parametersbull Position of measured values with respect to the
thresholds in the form of scales with green yellow and red zones
bull Time history (trend) for each measured value
Physical characteristicsTemperature range bull minus 10 divide + 50 ordmC
Maximum number of connected devicesbull measuring devices 15bull external audible and visual alarm 15
Display diagonal bull 152 cm (6)
Electrical characteristicsbull Interfaces RS-485bull Power supply 220 V 50 Hz 12 divide 24 V
Mechanical characteristicsbull Protection index IP54bull Paint decontaminable
Overall dimensions weightbull 296x248x118 mm 5 kg
DBG-S11D wide range gamma area monitor
UDMN-100 neutron area monitor
Ethernet RS-485
UDKS-100 gamma and X-ray area monitor
BPI-1D Local display unit
BAS-2 ldquoMicrordquo external visual alarm
BZS-2 ldquoMicrordquo external audible alarm
ldquoImpulsrdquo external display unit
Service workstation
Illuminated warning signs
SPC ldquoDozardquoRadiation monitoring equipment
4140
Continuous automatic monitoring of the gamma- X-ray ambient dose equivalent rate
Physical characteristicsbull Detector tissue-equivalent plastic scintillator
Oslash 45times20 mm
Measurement range bull Dose rate measurement range 01 μSvh divide 1 Svh bull Energy range 0015 divide 10 MeV
Mechanical characteristicsbull Protection index IP65bull Paint decontaminable
Overall dimensions weightbull Oslash72times265 mm 15 kg
UDKS-100 GAMMA AND X-RAY AREA MONITOR
UDMN-100 NEUTRON AREA MONITOR
Physical characteristicsbull detector ndash scintillator ZnS(Ag) Li-6
Measurement range bull 01 μSvh divide 01 Svh
Energy range bull 0025 eV divide 100 MeV
Temperature range bull minus 45 divide +50 ordmC
Electrical characteristicsbull Interfaces RS-485
Mechanical characteristicsbull Protection index IP 65bull Paint decontaminable
Overall dimensions weight bull 428times258times347 mm 115 kg
Continuous automatic monitoring of the neutron-radiations ambient dose equivalent ratebull Spherical polyethylene moderator Oslash 239 mm
MEASURING UNITS
DBG-S11D WIDE RANGE GAMMA AREA MONITOR
Continuous automatic monitoring of the gamma- ambient dose equivalent rate
Physical characteristicsbull Detector ndash GM counters
Measurement rangebull DBG-S11D 01 μSvh divide 10 mSvhbull DBG-S11D-01 01 μSvh divide 10 Svhbull DBG-S11D-02 01 μSvh divide 100 Svh
Energy rangebull 005 divide 30 MeV
Temperature range bull minus 40 divide +50 ordmC
Electrical characteristicsbull Interfaces RS-485 USB
Mechanical characteristicsbull Protection index IP 68bull Paint decontaminable
Overall dimensions weightbull DBG-S11D Oslash 68times141 mm 065 kg bull DBG-S11D-01 Oslash 68times179 mm 07 kgbull DBG-S11D-02 Oslash 68times179 mm 07 kg
Versionsbull DBG-S11Dbull DBG-S11D-01bull DBG-S11D-02
Reference standards Nuclear IEC 60846 IEC 60532 EMC IEC 61010 IEC 61000-6-2 Seismic IEC 60980
SPC ldquoDozardquoRadiation monitoring equipment
4342
ALARM UNITS
Generation visual signals of the excess of preset thresholds
Physical characteristicsLength of communication cablebull up to 1200 mbull Alarm Visual alarm green yellow red
Electrical characteristicsbull Power supply +12 V
Mechanical characteristicsbull Protection index IP 23
Overall dimensions weight 160times84times41 mm 02 kg
BAS-2 ldquoMICROrdquo EXTERNAL VISUAL ALARM
Generation audible signals of the excess of preset thresholds
Physical characteristicsLength of communication cablebull up to 1200 mbull Audible alarm 80 divide 100 dB at a distance of 1 m
Electrical characteristicsbull Power supply +12 V
Mechanical characteristicsbull Protection index IP 23
Overall dimensions weight 160times84times41 mm 02 kg
BZS-2 ldquoMICROrdquo EXTERNAL AUDIBLE ALARM
Physical characteristicsLength of communication cablebull up to 1200 m
Electrical characteristicsbull Power supply 220 V 50 Hz
Mechanical characteristicsbull Protection index IP 23
Overall dimensions weight bull 330times110times20 mm 05 kg
Physical characteristicsLength of communication cablebull up to 1200 m
Character height bull ldquoImpuls-910-Rrdquo 100 mmbull ldquoImpuls-915-D4Srdquo 150 mmbull ldquoImpuls-927-D4Srdquo 270 mm
Operating temperature rangebull ldquoImpuls-910-Rrdquo 0 divide +50 degCbull ldquoImpuls-915-D4Srdquo ldquo-727-D4Srdquo minus 40 divide +50 degC
Electrical characteristicsbull Power supply 220 V 50 Hz
Mechanical characteristicsProtection index bull ldquoImpuls-910-R IP 44bull ldquoImpuls-915-D4Srdquo ldquo-727-D4Srdquo IP 65
Overall dimensions weight bull ldquoImpuls-910-Rrdquo 400times160times60 mm 3 kgbull ldquoImpuls-915-D4Srdquo 815times250times80 mm 5 kgbull ldquoImpuls-927-D4Srdquo 1250times330times80 mm 5 kg
ILLUMINATED WARNING SIGNS
ldquoIMPULSrdquo EXTERNAL DISPLAY UNIT
SPC ldquoDozardquoRadiation monitoring equipment
4544
Individual threshold setting for each measurement channel
Continuous area and process monitoring
Collect amp display data from two measurement chan-nels (units with RS-485 or analog pulses)
Audible and visual alarms on exceeding preset thresholds or status of connected devices
Individual threshold setting for each measurement channel
Switching on the external alarm or executive devices when any threshold is exceeded
The wide panel displays the following information bull Values of measured parameters as min-1∙cm-2
s-1∙cm-2 μSvhbull Diagnostic information about the status of con-
nected devicesbull Current date and timebull Position of measured values with respect to the
thresholds in the form of scales with green yellow and red zones
bull Time history (trend) for each measured value
Physical characteristics Measurement range bull Count rate up to 107 CPM (170 kHz)
Operating temperature range bull minus 20 divide +50 ordmC
Electrical characteristics bull Power supply 220 V bull Interfaces USB
Mechanical characteristics bull Protection index IP 65 bull Overall dimensions weight 222times164times73 mm
40 kg
UIM-3D AREA MONITOR COUNT RATE METER
Measurement of alpha radiation flux density
Detector unit BDZA-100 (70 cm2) Measurement range 01 divide 104 min-1∙cm-2
Detector unit BDZA-100B (300 cm2) Measurement range 01 divide 2103 min-1∙cm-2
Measurement of beta radiation flux density
Detector unit BDZB-100 (28 cm2) Measurement range 10 divide 105 min-1∙cm-2
Detector unit BDZB-100L (30 cm2) Measurement range 10 divide 104 min-1∙cm-2
Detector unit BDZB-11D (84 cm2) Measurement range 5 divide 15∙104 min-1∙m-2
OPTIONAL PROBESMeasurement of gamma radiation flux density
Detector units BDEG-03 Measurement range 4 divide 2000 s-1∙cm-2
Detector unit UDKG-100 for operation in the rocks ore liquid media and sludge Measurement range 40 divide 8000 s-1∙cm-2
Measurement of the ambient dose equivalent rate
Detector unit DBG-S11D Measurement range 01 μSvh divide 100 Svh
Measurement of neutron radiation ambient dose equivalent rate
Detector unit BDMN-100 Measurement range 01 μSvh divide 01 Svh
SPC ldquoDozardquoRadiation monitoring equipment
46 47Reference standards Nuclear IEC 61526
Measurement of gamma-radiation personal dose equivalent Hp(10)bull Stand-alone dosimeter or composed of dosimetric
system onebull Audible and visual alarmbull Large memory dose accumulation historiesbull Exclusion of unauthorized intervention in dosim-
etry operation
DKG-05D PERSONAL GAMMA DOSIMETER
Physical characteristicsDetectors bull Silicon
Measurement range bull Dose rate 1 μSvh divide 10 Svhbull Dose 01 μSv divide 15 Sv
Energy range bull 005 divide 30 MeV
Electrical characteristicsbull Power supply rechargeable NiMH battery 1
alcaline battery (type AAA)
Operation timebull Till recharging not less 400 hoursbull With one set batteries not less 1000 hours
Mechanical characteristicsOverall dimensions weight bull 47times26times87 mm (with clip) 70 g
Environmental characteristicsbull IP65bull Temperature range minus 20 divide +45 ordmCbull Humidity up to 98 at 35 ordmCbull Shock vibration and drop resistant
Alarmbull Excess of alarm thresholdsbull Warnings of self-test failure and battery discharge bull Audible alarm 80 dB at 40 cmbull Visual alarm blinking LED
Relative equipmentbull One dosimeter charger ZU-1Mbull Chargestorage cassetes KZU-28KZU-56bull ldquoSmart chargingrdquo feature extends battery life timebull DKG-05D reader US-05bull DKG-05D system reader DVS-01D
Reader-PC interfacebull US-05 USB bull DVS-01D Ethernet
KZU-28
Physical characteristicsDetectors bull Silicon Li-6
Gamma measurement range bull Dose rate 1 μSvh divide 10 Svhbull Dose 01 μSv divide 15 Sv
Gamma energy range bull 005 divide 60 MeV
Neutron measurement range bull Dose rate 1 μSvh divide 2 Svhbull Dose 20 μSv divide 15 Sv
Neutron energy range bull 0025 eV divide 20 MeV
Electrical characteristicsPower supply bull Rechargeable NiMH batterybull Operatiion time till recharging not less 200 hours
Mechanical characteristicsOverall dimensions weight bull 47times26times87 mm (with clip) 70 g
Environmental characteristicsbull IP65bull Temperature range minus 20 divide +40 ordmCbull Humidity up to 75 at 30 ordmCbull Shock vibration and drop resistant
Alarmbull Excess of alarm thresholds bull Warnings of self-test failure and battery discharge bull Audible alarm 80 dB at 40 cmbull Visual alarm blinking LED
Relative equipmentbull One dosimeter charger ZU-1Mbull Chargestorage cassetes KZU-28 KZU-56bull ldquoSmart chargingrdquo feature extends battery life timebull DVS-02D reader UZS-01Sbull DVS-02D system reader DVS-01D
Reader-PC interfacebull UZS-01S USB bull DVS-01D Ethernet
UZS-01DReference standards Nuclear IEC 61526
DVS-02D GAMMA-NEUTRON PERSONAL ELECTRONIC DOSIMETER
Measurement of gamma- and neutron radiations personal dose equivalent Hp(10)bull Stand-alone dosimeter or composed of dosimetric
system onebull Audible and visual alarmbull Large memory dose accumulation historiesbull Exclusion of unauthorized intervention in dosim-
etry operationbull Both albedo thermal neutrons and intermediate
fast neutrons registrationbull Usable in the fields of Pu(Be) Po(Be) Cf and other
neutron sources as well as near nuclear reactors without neutron spectrum estimation
SPC ldquoDozardquoRadiation monitoring equipment
48 49
Dosimeters DVG-03D
DVGI-8D NEW PEN-TYPE PERSONAL IONIZATION CHAMBER DOSIMETERS
Measurement of personal dose equivalent Hp(10) of gamma and X-ray radiationbull Hp(10) of continuous and pulsed gamma and
X-ray radiation bull Electronic reader KSU-1bull Dosimeter DVG-03D with electronic ID bull Personal dose histories in the readerrsquos memorybull Readerrsquos connection with PC for database main-
tenance
Physical characteristicsDetector bull Ionization chamber
Measurement range bull 001 mSv divide 25 mSv
Energy range bull 0015 divide 25 MeV
Temperature range bull Reader KSU-1 +10 divide +50 ordmСbull Dosimeter DVG-03D minus 40 divide +50 ordmС
Electrical characteristicsPower supply bull Reader KSU-1 220 V 50 Hz built-in batteries bull Dosimeter DVG-03D four batteries CR 1025 bull Batteries life 3 yearsbull Readers interfaces RS-232USB 20
Mechanical characteristicsOverall dimensions weightbull Dosimeter DVG-03D Oslash 18times126 mm 005 kgbull Reader KSU-1 235times232times125 mm 28 kg
Reference standards Nuclear IEC 62387-1
DKG-02U ldquoARBITERrdquo WIDE RANGE GAMMA-DOSIMETER
Physical characteristicsDetectors bull GM counters
Measurement rangebull Dose-rate 01 μSvh divide 3 Svhbull Dose 1 μSv divide 100 Sv
Energy range bull 005 divide 3 MeV
Electrical characteristicsbull Power supply 2 alcaline batteries (type AA)bull Batteries life not less 200 hours
Mechanical characteristicsOverall dimensions weight bull 152times82times32 mm 03 kg
Environmental characteristicsbull Temperature range minus 20 divide +50 ordmCbull Humidity up to 90 at +25 ordmCbull Shock vibration and drop resistant
Reference standards Nuclear IEC 60846
Measurement of gamma radiation ambient equiva-lent dose H(10) and dose rate H(10)bull Audible signals (clicks) for radiation condition
estimationbull Analog scale for search modebull Audible and visual alarms of the excess of preset
dose and dose rate thresholds bull Shock-resistant water-proof easy decontamina-
tion casebull 100 measurement results memory with date and
time of measurementbull Indication of total dose accumulated during
exploitation time bull Indication of measurement result statistical
uncertainty
SPC ldquoDozardquoRadiation monitoring equipment
50 51
Physical characteristicsDetectors bull GM counter
Measurement rangebull Dose-rate 01 μSvh divide 3 mSvhbull Dose 1 μSv divide 02 Sv
Energy range bull 005 divide 3 MeV
Temperature range bull Minus 20 divide +50 ordmC
Electrical characteristicsbull Power supply 2 alcaline batteries 15 V (type AA)bull Batteries life not less 200 hours
Mechanical characteristicsOverall dimensions weight bull 122times74times29 mm 025 kg
Reference standards Nuclear IEC 60846
DKG-07D ldquoDROZDrdquoGAMMA-DOSIMETER
Measurement of gamma radiation ambient equiva-lent dose H(10) and dose rate H(10)bull Two independent measurement channels dose
and dose ratebull Audible signals (clicks) for radiation condition
estimationbull Continuous measurement with updating meas-
urement resultbull Measurement result can be obtained with any
desired statistical uncertainty (error)bull Automatic restart when radiation level sharply
changesbull Indication of statistical uncertainty (error) during
measurement process
Continuous measurement with updating measure-ment result
Automatic restart when radiation level sharply changes bull Gamma dose H(10) and dose-rate H(10) meas-
urementbull Beta and gamma contamination surveybull Indication of statistical uncertainty during the
measurementbull Continuous measurement with accuracy increas-
ing with time bull Automatic restart triggered by change of gamma
dose-ratebull Compensation of gamma count rate while meas-
uring beta radiationbull Indication of battery charge levelbull Audible signal of the excess of preset threshold
Physical characteristicsDetectors bull GM counter
Measurement range bull Dose-rate 01 microSvh divide 20 mSvhbull Dose 1 microSv divide 100 Svbull Beta flux density (for Sr-90+Y-90)
10 divide 105 cm-2 min-1
Energy range bull Gamma 005 divide 3 MeVbull Beta 01 divide 3 MeV
Temperature range bull Minus 20 divide +50 ordmC
MKS-15D ldquoSnegirrdquo backside
MKS-15D ldquoSNEGIRrdquoMULTI ndash PURPOSE RADIATION SURVEY METER
Reference standards Nuclear IEC 60846 IEC 60325
Electrical characteristicsbull Power supply 2 alcaline batteries (type AA)bull Battery life not less 400 hours
Mechanical characteristicsOverall dimensions weight bull 124times72times35 mm 035 kg
SPC ldquoDozardquoRadiation monitoring equipment
52 53
Physical characteristicsDetectorbull GM counter
Measurement range bull 01 μSvh divide 20 mSvh
Energy range bull 005 divide 30 MeV
Threshold setting range bull 03 μSvh divide 20 mSvh
Step change of the thresholdbull In the range 03 divide 10 μSvh with the step
001 μSvhbull In the range 10 divide 100 μSvh with the step
01 μSvhbull In the range 100 divide 2000 μSvh with the step
10 μSvh
Electrical characteristicsPower supply bull 220 V 50 Hz bull Relay output
Mechanical characteristicsProtection index bull IP 40
Overall dimensions weight bull 226times120times75 mm 07 kg
Alarmbull Sound alarm 80 divide 100 dBA at distance 1 mbull Visual alarm redbull Connection of the external alarm signaling unit
Reference standards Nuclear IEC 60846 IEC 60532
Continuous automatic monitoring of the ambient dose equivalent rate bull Measurement of gamma dose rate H(10)bull Audible and visual alarm signals for preset
thresholdsbull Switching on the external signaling or executive
devices
SRPS-05D GAMMA MONITOR
Measurement ofbull Gamma and X-ray personal dose equivalent
Hp(10)bull Neutron personal dose equivalent Hp(10)bull Lens dose equivalent Hp(3)bull Skin dose equivalent Hp(007)bull TLD reader day-to-day tests using built-in LEDbull No needs nitrogen for heating
Physical charachteristicsDetectors bull 7LiF Mg Ti (gamma beta)bull 6LiF Mg Ti (neutron)
Gamma and X-ray Hp(10) Measurement range bull 500 μSv divide 10 Sv
Energy range bull 0015 divide 30 MeV
Neutron Hp(10)Measurement range bull 01 mSv divide 100 mSv
Energy range bull 0025 eV divide 10 MeV
Beta and photons Hp(007) Hp(3) Measurement range bull 2 mSv divide 100 Sv
Energy range bull Beta 025 divide 35 MeVbull Photons lt15 keV
Mechanical characteristicsDosimeters overall dimensions weight bull Gamma Hp(10) DTL-2 holder - 62times26times16 mm
16 gbull DTU holder - 42times28times18 mm 8 gbull Lens Hp(3) face skin Hp(007) Oslash 32times16 mm 9 gbull Finger skin Hp(007) 90times20times2 mm 1 gbull Neutron gamma Hp(10) 48times40times20 mm 30 g
Reference standards Nuclear IEC 61066
DTL-2 DTU-2
MKD (A-type) DVNG-M
DOZA-TLD MULTIPURPOSE TLD SYSTEM
SPC ldquoDozardquoRadiation monitoring equipment
54 55
Continuous and pulsed gamma and X-ray dose H(10) and dose-rate measurementbull Alpha beta and gamma contamination surveybull Neutron dose H(10) and dose-rate measurementbull Gamma radiation flux density in boreholes and
liquid media measurement
Electrical characteristicsPower supply bull UIK-05 four C-size batteriesbull UIK-05-01 rechargeable batterybull UIK-06 rechargeable battery
Interfaces bull RS-232bull USB (via adapter)
bull Detector type automatic determination and corre-sponding measurement modes selection
bull Alarm threshold settings ndash for dose dose-rate alpha and beta contaminations
bull ldquoDetectrdquo and ldquoLocaterdquo modes for survey probes
Reference standards Nuclear IEC 60846 IEC 60325 IEC 61005 IEC 62363
Case
UIK-06 control unit165times78times48 mm 03 kg
DKS-96UNIVERSAL RADIATION SURVEY METER
UIK-05 control unit202times86times90 mm 10 kg
BDZA-96
BDZA-96B
BDZA-96M
BDZA-96S
BDZA-96T
EXTERNAL PROBES ALPHAALPHA BDZA-96Detector bull ZnS(Ag) 70 cm2
Measurement range (for Pu-239)bull 01 divide 104 min-1cm-2
Overall dimensions weightbull Oslash 130times240 mm 11 kg
ALPHA BDZA-96BDetector bull ZnS(Ag) 300 сm2
Measurement range (for Pu-239)bull 01 divide 2103 min-1cm-2
Overall dimensions weightbull Oslash 230times290 mm 40 kg
ALPHA BDZA-96MDetector bull ZnS(Ag) 10 сm2
Measurement range (for Pu-239)bull 01 divide 105 min-1cm-2
Overall dimensions weightbull Oslash 65times240 mm 09 kg
ALPHA BDZA-96SDetector bull ZnS(Ag) 30 сm2
Measurement range (for Pu-239)bull 01 divide 5104 min-1cm-2
Overall dimensions weightbull Oslash 90times240 mm 10 kg
ALPHA BDZA-96TDetector bull Silicon 5 сm2
Measurement range (for Pu-239)bull 01 divide 106 min-1cm-2
Overall dimensions weightbull Oslash 50times60 mm 015 kg
SPC ldquoDozardquoRadiation monitoring equipment
56 57
BETA BDZB-96Detector Scintillator 28 сm2
Measurement range (for Sr-90+Y-90)bull 10 divide 105 min-1cm-2
Energy rangebull 03 divide 30 MeV
Overall dimensions weightbull Oslash 90times230 mm 09 kg
BETA BDZB-99Detector bull GM counter 30 сm2
Measurement range (for Sr-90+Y-90)bull 20 divide 104 min-1см-2
Energy rangebull 012 divide 30 MeV
Overall dimensions weightbull Oslash 88times80 mm 04 kgbull Telescopic pole length 07 m
BETA BDZB-96BDetector bull GM counter 80 сm2
Measurement range (for Sr-90+Y-90)bull 3 divide 104 min-1сm-2
Energy rangebull 012 divide 30 MeV
Overall dimensions weightbull 150times200times110 mm 15 kg
BETA BDZB-96Sbull Detector GM counter 15 сm2
Measurement range (for Sr-90+Y-90)bull 10 divide 3104 min-1cm-2
Energy rangebull 012 divide 30 MeV
Overall dimensions weightbull Oslash 65times65 mm 03 kgbull Telescopic pole length 07 m
BDZB-96
BDZB-99
BDZB-96B
BDZB-96S
EXTERNAL PROBES BETA
GAMMA BDKS-96BDetector bull Tissue-equivalent scintillator Oslash 45times20 mm
Measurement rangebull Dose rate H(10) 01 μSvh divide 1 Svhbull Dose H(10) 01 μSv divide 10 Sv
Energy rangebull 0015 divide 10 MeV
Overall dimensions weightbull Oslash 60times250 mm 085 kg
GAMMA AND BETA BDKS-96SDetector bull Double GM counters
Measurement rangebull Gamma dose rate H(10) 01 μSvh divide 1 mSvhbull Gamma dose H(10) 01 μSv divide 10 Svbull Beta 10 divide 3104 min-1cm-2
Energy rangebull Gamma 005 divide 3 MeVbull Beta 012 divide 3 MeV
Overall dimensions weightbull Oslash 80times80 mm 035 kgbull Telescopic pole length 07 m
GAMMA BDMG-96Detector bull GM counters
Measurement rangebull Dose rate H(10) 01 μSvh divide 10 Svhbull Dose H(10) 01 μSv divide 10 Sv
Energy range bull 005 divide 3 MeV
Overall dimensions weightbull 40times250 mm 05 kgbull Telescopic pole length 07 m 4 m (by request)
EXTERNAL PROBES GAMMA
BDKS-96B
BDMG-96
BDKS-96S
SPC ldquoDozardquoRadiation monitoring equipment
58 59
GAMMA-SEARCH BDVG-96Detector bull Scintillator NaI(Tl) Oslash 63times63 mm
Measurement rangebull Flux density measurement range 4 divide 2000 s-1cm-2
bull Dose rate H(10) for Cs-137 01 divide 30 μSvhbull Sensitivity for Cs-137 3000 (pulsess-1)( μSvh-1)
Overall dimensions weightbull Oslash 88times400 mm 20 kgbull Modular pole length 16 m
GAMMA-SEARCH BDPG-96Detector bull Scintillator NaI(Tl) Oslash 25times40 mm
Measurement rangebull Flux density measurement range 10 divide 8000 s-1cm-2
bull Dose rate H(10) for Cs-137 01 divide 100 μSvhbull Sensitivity for Cs-137 500 (pulsess-1)( μSvh-1)
Overall dimensions weightbull 50times190times480 mm 10 kgbull Telescopic pole length 07 m
GAMMA-SEARCH BDPG-96MDetector bull Scintillator NaI(Tl) Oslash 18times30 mm
Measurement rangebull Flux density measurement range 10 divide 24000 s-1cm-2
bull Dose rate H(10) for Cs-137 01 divide 300 μSvhbull Sensitivity for Cs-137 200 (pulsess-1)( μSvh-1)
Overall dimensions weightbull Oslash 35times320 mm 05 kgbull Telescopic pole length 07 or 38 m
EXTERNAL PROBES GAMMA
BDVG-96
BDPG-96M
BDPG-96
EXTERNAL PROBESGAMMA BDKG-96 STAINLESS STEEL CASING FOR GEOLOGIC APPLICATIONS WELL LOGGINGDetector bull Scintillator NaI(Tl) Oslash 18times30 mm
Measurement rangebull Flux density measurement range 10 divide 105 s-1cm-2
bull Dose rate H(10) for Cs-137 5 divide 2104 μRhbull Sensitivity for Cs-137 200 (pulsess-1)( μSvh-1)
Overall dimensions weightbull Oslash 38times535 mm 36 kgbull Cable length 10 divide 1000 m
NEUTRON BDMN-96Detector bull Scintillator with ZnS(Ag)
Measurement rangebull Dose rate H(10) 01 μSvh divide 01 Svhbull Dose H(10) 01 μSv divide 10 Sv
Energy range bull 0025 eV divide 10 MeV
Overall dimensions weightbull Detector Oslash 54times200 mm 08 kgbull Moderator Oslash 245 mm 73 kg
NEUTRON-SEARCH BDKN-96Detector bull He-3 counter in polyethilene moderator
Measurement rangebull Dose rate H(10) for Pu-Be 01 μSvh divide 01 Svhbull Dose H(10) for Pu-Be 01 μSv divide 10 Sv
Energy range bull 0025 eV divide 14 MeV
Overall dimensions weightbull 295times142times100 mm 225 kg
BDKG-96M
BDMN-96
BDKN-96
SPC ldquoDozardquoRadiation monitoring equipment
60 61
bull No gas supply neededbull Clothing control detachable right hand detector bull Alpha detector optional connection bull Numeric and color (red green) indication of
control resultsbull LED sensor of hand-foot positioning for start of
measurementbull Automatic compensation of gamma background
and contamination of detectorbull Audible alarm signals of the excess of preset
thresholdsbull Measurement value indication min-1cm-2 or
Bqсm2
Reference standards Nuclear IEC 61098
RZB-05D HAND-FOOT-CLOTHING MONITOR
Physical characteristicsDetectors bull Gamma beta - GM countersbull Alpha - scintillatior ZnS(Ag)
Detecting nuclidesbull Alpha Pu-239 U-234 U-238bull Beta Sr-90+Y-90 F-18 Cs-137 Co-60 Tс-99 O-15
N-13 Sr-89 C-11 I-131 Na-22 Ru-106+Rh-106 Tl-204
bull Gamma Tc-99m I-123
Efficiencybull Alpha
Pu-239 40 U-234 25U-238 15
bull Beta Sr-90 +Y-90 40
Measurement range bull Alpha 1 divide 103 min-1cm-2 bull Beta 10 divide 103 min-1cm-2
bull Gamma 5103 divide 5106 min-1cm-2
Energy range bull Alpha 30 divide 80 MeV bull Beta 008 divide 35 MeV bull Gamma 005 divide 30 MeV
Operation temperature range bull Minus 10 divide +50 ordmС
Electrical characteristicsbull Power supply 220 V 50 Hz
Mechanical characteristicsOverall dimensions weight bull 740times750times1180 mm 45 kg
Versionsbull Withwithout alpha detectorbull Indication (min-1cm-2 ) or (Bqсm2)bull Detectors overall dimensions smbull Hand 178 х 235bull Foot 185 х 436
Whole body contamination monitor RZBA-04-04Mbull No gas supply neededbull Compensation for background gamma radiation
and contamination of detector unitsbull Individual threshold setting for each measure-
ment channelbull Visible and audible alarms ldquoCONTAMINATIONrdquo and
ldquoCLEANrdquo bull Indication of contaminated body parts on the
panel with image of the bodybull Optional remote alpha-detector
Physical characteristicsDetectors bull Beta - GM counters scintillatorsbull Alpha - scintillatior ZnS(Ag)
Measurement range bull Beta 5 divide 15000 min-1cm-2
bull Alpha 01 divide 10000 min-1cm-2
Energy range bull Beta 015 divide 25 MeV bull Alpha 40 divide 56 MeV
Operation temperature range bull +5 divide +50 ordmС
Electrical characteristicsPower supply bull 220 V 50 Hz
Interfaces bull RS-232bull RS-485
Mechanical characteristicsOverall dimensions weight bull 2650times940times930 mm 310 kg
Versionsbull Withwithout alpha detectorbull Indication (min-1cm-2 ) or (Bqсm2)
Reference standards Nuclear IEC 61098
RZBA-04-04MWHOLE BODY CONTAMINATION MONITOR
SPC ldquoDozardquoRadiation monitoring equipment
62 63
RZA-05DALPHA HAND-MONITOR
bull No gas supply needed bull Numeric and color (red green) indication of
control resultsbull LED sensor of hand- positioning for start of
measurementbull Audible alarm signals of the excess of preset
thresholdsbull Measurement value indication min-1cm-2 or
Bqсm2
Physical characteristicsDetectors alpha - scintillatior ZnS(Ag)
Efficiencybull Pu-239 20 bull U-234 14bull U-238 8
Measurement range bull 05 divide 105 min-1cm-2
Energy range bull 41 divide 90 MeV
Operation temperature range bull minus 10 divide +50 ordmС
Electrical characteristicsPower supply bull 220 V 50 Hz
Mechanical characteristicsOverall dimensions weight no more bull 740times1400times1450 mm 70 kg
Reference standards Nuclear IEC 61098
bull Simultaneous measurement of alphabeta activi-ties in the sample
bull Active shielding anti-coincidence background subtraction using GM counters
bull Lead shielding 30 mm
UMF-2000 LOW LEVEL ALPHA- BETA- COUNTER
Physical characteristicsDetectors bull Silicon specrometric detector 500 or 1000 mm2
Measurement range bull Alpha 001 divide 1000 Bq bull Beta 01 divide 3000 Bq
Energy range bull Alpha 35 divide 80 MeV bull Beta 005 divide 35 MeV
Electrical characteristicsPower supply bull 220 V 50 Hz
Interfaces bull RS-232bull USB
Mechanical characteristicsOverall dimensions weight bull 337times286times190 mm 22 kg
Versionsbull Detector area 500 mm2
bull Detector area 1000 mm2
UMF-2000 Detector area 1000 mm2
UMF-2000 Detector area 500 mm2
SpectraDec software for alpha-spectrometric measurements
SPC ldquoDozardquoRadiation monitoring equipment
64 65
DRK DOSE AREA PRODUCT METER
DRK-1bull Diagnostic reference level (DRL) of patients
determinationbull Suitable for all basic types of x-ray machines
Physical characteristicsDetector bull Plane-parallel ionization chamber
Measurement range bull 1 divide 104 cGycm2
Electrical characteristicsPower supply bull 220 V 50 Hz
DRK-1M-CTbull Measuring of dose length product
Physical characteristicsDetector bull Pencil Ionization Chamber
Measurement rangebull 05 divide 109 microGym
DRK-1Mbull Measuring of air kerma on sectional area of the
X-ray beam productbull Measuring of air kerma rate on area productbull Measuring of air kerma ratebull Measuring of air kerma
Physical characteristicsDetector bull Plane-parallel ionization chamber
Measurement rangebull 01 divide 109 microGym2
bull 06 divide 6104 microGym2cbull 30 divide 9105 microGycbull 30 divide 9991011 microGyReference standard IEC 60580 2003
bull Measurement of strontium-90 in the foodstuffs agricultural products etc
bull Measurement of gross beta activity in samplebull Self tests using built-in LED
ldquoPROGRESS-BETArdquo SCINTILLATION BETA SPECTROMETER
Physical characteristicsDetector bull Plastic scintillator Oslash70x10 mm
Sample bull Plate Oslash70 mmbull Weight up to 15 g
Energy range bull 02 divide 30 MeV
Minimum detectable activity of Sr-90 in a 10 g sample on a standard planchet Bqsamplebull In case of absence of K-40 in the sample 01 Bqbull In case the activity of K-40 till 5 Bqg 05 Bq
Electrical characteristics Interface bull USB
Mechanical characteristicsWeight bull No more 50 kg
Complete setBasic complete setbull Detector unit with plastic scintillator integrated
power supply amplifier ADC bull Lead shielding bull ldquoProgressrdquo software bull Сheck source for energetic calibration (Sr-90-Y-90) bull Planchet Oslash 70 mm (5 items) bull Sample dencification device bull Procedure manual for measurement of radio-
nuclidesrsquo activity using the scintillation beta spec-trometer ldquoProgressrdquo
Optional equipment and servicebull Personal computer and printer bull Calibrations for radionuclides not included in the
main library of radionuclides
Progress-Beta
Reference standards IEC 61562
SPC ldquoDozardquoRadiation monitoring equipment
66 67
bull Measurement of gamma activity in foodstuffs soil samples and others environmental objects
bull Identification of radionuclides in the sample bull Automatic correction for sample density bull Self-tests using built-in LED
ldquoPROGRESS-GAMMArdquoSCINTILLATION GAMMA SPECTROMETER
Physical characteristicsDetector bull NaI (Tl) Oslash63times63 mm
Validated measurement geometries bull Marinelli beakers (1 liter) Petri dishes (Oslash90 mm)
etc
Energy range bull 02 divide 30 MeV
Minimum detectable activity Bqsamplebull Cs-137 3 Bqbull Th-232 7 Bqbull Ra-226 8 Bq bull К-40 40 Bq
Electrical characteristics Interface bull USB
Mechanical characteristicsWeight bull No more 120 kg
Complete setBasic complete setbull Scintillation detector unit with NaI (Tl) detector
with integrated power supply amplifier and ADC bull Lead shielding 50 mm bull ldquoProgressrdquo software bull Сheck source for energy calibration (Cs-137 +
K-40)bull Marinelli beakers - 1 liter (5 items) bull Petri dishes Oslash 90 mm (5 items) bull Procedure manual for measurement of activity
of radionuclides using the scintillation gamma spectrometer ldquoProgressrdquo
Optional equipment and servicebull Kit for radon measurements including calibration
of ldquoIC-63rdquo geometry for counting the charcoal samples
bull Personal computer and printer bull Calibrations for user defined geometries bull Calibrations for radionuclides not included in the
main library of radionuclides
Progress-Gamma
Reference standards IEC 61563
ldquoPROGRESS-G(P)rdquoPORTABLE SCINTILLATION GAMMA SPECTROMETERbull Field measurements of gamma activity in environ-
mental objects without sampling (4π geometry)bull Laboratory measurement of gamma activity in
foodstuffs soil samples and others environmental objects
bull Identification of radionuclides in the sample bull Automatic correction for sample densitybull Tests using built-in LED
Physical charachteristicsDetector bull NaI (Tl) Oslash45times50 mmbull Lead shielding 20 mm
Validated measurement geometries bull Marinelli beakers (05 liter) Petri dishes (Oslash90 mm)
etc
Energy range bull 02 divide 30 MeV
Minimum detectable activity in 05-litre Marinelli beaker bull Cs-13710 Bqkgbull К-40100 Bqkgbull Ra-22618 Bqkg bull Th-23216 Bqkg
Minimum detectable activity in 30 min (4π geometry) bull Cs-137 2 Bqkgbull К-40 30 Bqkgbull Ra-226 4 Bqkg bull Th-232 3 Bqkg
Electrical characteristicsPower supply bull Rechargeable batterybull 220 V 50 Hz
Interface bull USB RS-232
Weight bull No more than 60 kg
Complete setBasic complete setbull Scinttillation detector unit with NaI(Tl) bull ldquoProgressrdquo softwarebull Сontrol unit ldquoSputnikrdquo for aquisition and analisys
of spectra with built-in memory for spectral databull Casebull Lead shielding (2 cm) for laboratory usebull 05-litre Marinelli beakers ndash 5 itemsbull Na-22 check sourcebull Power adapter BPS-01bull Operation manualbull Procedure manual for measurement of activity
of radionuclides using the scintillation gamma spectrometer ldquoProgressrdquo
Optional equipment and servicebull Kit for radon measurements with charcoalbull Built-in dose rate meterbull Additional memory (RAM) for storage of 64
spectrabull Additional power adapterbull Notebook and printer
Progress-Gamma
Reference standards IEC 61563
SPC ldquoDozardquoRadiation monitoring equipment
68 69
Physical characteristicsDetectorbull Scintillation detector ZnS (Oslash 60 mm)
Samplebull Thin sample - diameter up to 70 mm bull Preparation technique - electro-depositionbull Thick sample - diameter 70 mm weight
200300 mg bull Preparation technique - application of powders
(prepared by radiochemical concentration by water evaporation or by pounding of mineral samples) onto a planchet with the help of spirit
Energy rangebull 15 divide 8 MeV
Minimum detectable activitybull Thin samples no more than 910-3 Bqsamplebull Thick samples no more than 180 Bqkg
Mechanical characteristicsOverall dimensions weightbull 195times120times210 mm 34 kg
Complete setBasic complete setbull Alpha radiometer ldquoProgress-ARrdquobull Check source (uranium isotopes)
Set of accessoriesbull Procedure manual for measurements of radi-
oactivity using scintillation alpha radiometer ldquoProgress-ARrdquo
bull ldquoProgressrdquo software
ldquoProgress-ARrdquo
bull Measurement of gross activity of alpha emitting radionuclides in thin samples
bull Measurement of gross activity of alpha emitting radionuclides in thick samples
bull Measurement of activity deposited on aerosol filters
ldquoPROGRESS-ARrdquoALPHA RADIOMETER
Several fixed positions of the detector enable to perform measurements in various geometries and to estimate the content ofbull Cs-137 in the whole bodybull I-131 in thyroidbull Co-60 Cs-137 Mn-54 Cr-51 in lungsbull Database for storage of measurement data and
resultsbull Uncertainty calculations based on measurement
databull Self tests using built-in LED
ldquoPROGRESSrdquo WHOLE BODY COUNTER
Physical characteristicsDetectorbull scintillation detector NaI (Tl) Oslash63times63 mm
Energy rangebull 02 divide 28 MeV
Minimum detectable activitybull By Cs-137 in the whole body - 1200 Bqbull By I-131 in thyroid - 100 Bqbull By Co-60 Cs-137 Mn-54 Cr-51 in lungs - 200 Bq
Mechanical characteristicsWeight bull No more than 120 kg
Complete setBasic complete setbull Collimator with rotator and holderbull Detector with incorporated ADCbull Patient chair and table for collimatorbull Check source Na-22bull Procedure manual for lifetime measurement of
gamma-emitting radionuclidesrsquo activity in human body using the gamma-spectrometer of human radiation ldquoProgressrdquo
bull laquoProgressraquo software
Optional equipment and servicebull Program of internal radiation committed internal
radiation effective dose calculation by the stand-ard model
bull Background phantombull Personal computer and printer
Collimator with rotator and holder
SPC ldquoDozardquoRadiation monitoring equipment
70 71
bull Categorization of wastes for the purpose of fur-ther processing including wastes with unknown radionuclide composition
bull Measurements during the incoming waste inspec-tion (accepting for storage disposal)
bull Certification of unconditioned and conditioned wastes in closed containers without opening them (at nuclear plants or at facilities providing collection storage transportation conditioning processing temporal storage and final disposal of radioactive waste)
bull Activity measurement of extended objects in situ without opening the equipment
bull Activity measurement of extended objects after opening (for example assessment of tubes used for oil transportation)
MKG-01D ldquoSADOVNIKrdquoSPECTROMETRY SYSTEM
Physical charachteristicsDetectorbull Detector unit GEM (GMX) with HPGe detector and
multi-positioning cryostat CFG-PMOD4-7 with 7 litre Dewar
bull Dose rate probe BDMG-200
Energy range bull With GEM detector 004 divide 30 MeVbull With GMX detector 0005 divide 15 MeVbull Dose rate probe BDMG-200 ndash 005 divide 30 MeV
Measurement rangebull 110-7 divide 10 Svhbull Relative efficiency of detection (in photopeak) at
13325 MeV (Co-60) 10 divide 150
Electrical characteristicsPower supplybull 220 V 50 Hz
Interfacebull USB
Complete setBasic complete setbull Spectrometric detector unit GEM (GMX) with
HPGe detector and multi-positioning cryostat with 7 litre Dewar
bull Portable digital multichannel analyzer DigiDARTbull Dose rate probe BDMG-200bull Autonomous power supply unit with built-in
batterybull Industrial computer keyboardbull Laser range-finderbull Thermographic printerbull Web-camerabull Device equipped with stepper motor for position-
ing of the spectrometric detectorbull Calibration device with reference sources
(Am-241 Co-60 Ba-133 Eu-152) for energy calibration
bull Removable collimators with end capbull Measurement proceduresbull ldquoClasterrdquo software
bull Measurement of gross alpha activity of alpha-emitting radionuclides
bull Measurement of alpha-emitting radionuclides activity in thin-layer samples meeting alpha-spectrometry requirements
Physical characteristicsDetectorbull Silicon ion-implanted 450 mm2
bull Easy to decontaminate thin windowbull dead layer less than 015 μmbull Background count rate in the range 3 divide 9 MeVbull No more than 09 h-1cm-2 for 450 mm2 detector
Energy rangebull 2 divide 9 MeVbull Lower limit of measurement range (minimum
detectable activity) 01 Bqbull Background count rate no more than 100 counts
in 24 hours
Electrical characteristics Power supplybull 220 V 50 Hz
Interfacebull USB
Complete setBasic complete setbull Detector unit with vacuum measuring chamber
and vacuum control systembull Low noise vacuum pump (type 2FY-05B or
equivalent)bull Check sourcebull ldquoProgressrdquo softwarebull Vacuum tube
MKS-01A ldquoMULTIRAD-ASrdquoALPHA SPECTROMETER
SPC ldquoDozardquoRadiation monitoring equipment
72 73
UCRV-2AIRFLOW MONITOR
bull Monitor of the air flow through filter of centralized multichannel sampling system
bull Radiation monitoring system (RMS) integration for internal exposures determination
bull Volume and flow rate measurements of the air that have passed through a analytical filter
bull Bar-code for filter identificationbull Operation as either standalone unit or as a part of
the RMS
Physical characteristicsMeasurement range of air volume bull 001 divide 9999 m3
Operation temperature range bull minus 20 divide +50 ordmС
Electrical characteristicsPower supply bull 220 V 50 Hz
Interface bull RS-485
PVP-06PORTABLE AIR SAMPLER
Air Sampler PVP-06 is indispensable for monitoring the radiation situation where the concentration of radioactive aerosols in the air does not require a sta-tionary sampling equipment Sampling head PVP-06 provides easy change of filters and cartridges
Purposebull To monitor the concentration of radioactive aero-
sols in the air sites
Controlled aerosolsbull Alpha- and beta-active aerosolsbull Daughter products of decay of radon and thoronbull Iodine isotopes
Physical characteristicsTypes of filtersbull Aerosol AFA-RSP-20bull Iodine AFA SI-20
Flow rate bull 33∙10-4 ndash 233∙10-4 m3s (20 divide 140 l min)
Electrical characteristicsPower supply bull 220 V50 Hzbull The vehicle power supply 108 divide 145 Vbull Internal battery
Minimal working time on internal battery to recharge bull 8 hours
Power consumption (at a flow rate of 100 lmin) bull 40 VA
Environment characteristicsOperating temperature bull minus 10 divide +40 deg C
Maximum humidity bull 90
Pressure bull 860 to 1060 hPA
Noise generated by the pump bull lt 55 dBA at 1 m
Mechanical characteristicsDimensions weight bull 241 times 108 times 160 mm 28 kg
Case material bull Plastic
Complete setbull Air sampler PVP-06bull AC power adapterbull Filters AFA-RSP-20 - 100 pcsbull Packaging for filters - 40 pcsbull Casebull Operation manualbull Calibration certificate
Optional equimpient bull Kit for sampling sorption columns of activated
carbon Ř head of sorption columns with protective
covers Ř activated charcoal SKT-3 - 1 pkg (02 L) Ř charocoal samples SC-13 - 8 pcs
bull Car charger bull Tipod bull Shoulder strapbull Calibration stand bull Filters AFA SI-20 - 100 pcs
Consumablesbull Aerosol filters AFA RSP-20bull Iodine filters AFA SI-20
SPC ldquoDozardquoRadiation monitoring equipment
74 75
Calibration of gamma dose and dose rate meters
Calibration ofbull Ambient equivalent dose H(10) meters (Sv Svh)bull Personal equivalent dose Hp(10) meters (Sv Svh)bull Exposure dose X meters (R Rh)bull Two sources in irradiator bull Select source and collimator opening using
tumbler
UPG-P DESKTOP GAMMA BEAM IRRADIATOR
Physical characteristicsRange of reproduced dose rate bull 05 μSvh divide 10 mSvh (50 μRh divide 100 mRh)
Sources activities bull 6times106 6times108 Bq (02 20 mCi) Cs-137
Overall dimensions bull 1250times400times300 mm
Irradiator weight bull Not more than 37 kg
Calibration bench weight bull Not more than 15 kg
Reference standards IEC 60846 IEC 61526
Physical characteristicsDetectorbull Silicon
Measurement range EEC measurement bull Measurement range of radon EEC
10 divide 10bull106 Bqbullm-3
bull Measurement range of thoron EEC 05 divide 10bull104 Bqbullm-3
bull Air flow through the filter 100plusmn05 lmin
Concentration measurementbull Measurement range of radon-222 concentration
in air 10 divide 20bull106 cpsbull Measurement range of 216Po(ThA)
1bull10-3 divide 1bull102 cpsbull Air sampler flow rate
10plusmn02 lminbull Measurement range of radon-222 concentration
in water samples 6 divide 800 Bqbullkg-1
bull Measurement range of radon-222 flux from soil surface 20 divide 103 mBqsbullm2
bull Measurement range of radon-222 concentration with preliminary sampling of air using air sam-plers 20 divide 107 Bqbullm-3
bull Measurement range of radon-222 concentration in samples of soil air 103 divide 106 Bqbullm-3
Operation temperature range bull 1 divide 35 ordmC
Electrical characteristicsPower supply bull 80 VA
Mechanical characteristicsOverall dimensions weight bull 220times200times165 mm 36 kg
ldquoALPHARAD PLUSrdquoRADON THORON amp THEIR PROGENY MONITORbull Measurement of radon and thoron concentration
and effective equivalent concentration (EEC)bull In the airbull In the indoor air of residential public and industri-
al buildings and structuresbull Measurement of radon in drinking water sourcesbull Measurements of radon flux from the soil surface
at land plots allocated for construction of houses public buildings and industrial facilities
bull Measurements of radon concentration in soil air
Reference standards IEC 61577
SPC ldquoDozardquoRadiation monitoring equipment
76 77
UKPN-2M-D NEUTRON BEAM IRRADIATOR
Reference standards IEC 61005 61322
Calibration of neutron dose and dose rate meters
Calibration ofbull Ambient equivalent dose H(10) meters (Sv Svh)bull Personal equivalent dose Hp(10) meters (Sv Svh)bull Flux density of neutrons (cm-2∙s-1)bull Transfer container for temporary storage of
sources bull Red light signal of source working position
Physical carachteristicsRange of reproduced dose ratebull 20 divide 800 μSvh
Range of reproduced flux densitiesbull 10 divide 400 cm-2∙s-1
Type of a source in use bull Pu-Be
Activity of a source in usebull 24х1011 Bq (with density of 107 s-1)
Overall dimensions weight no morebull 3000x750x2000 mm 300 kg
Required room dimensionsbull not less than 7x3x3 m
Electrical characteristicsPower supply bull 220 V 50 Hz
Calibration of gamma dose and dose rate meters
Calibration ofbull Ambient equivalent dose H(10) meters (Sv Svh)bull Personal equivalent dose Hp(10) meters (Sv Svh)bull Exposure dose X meters (R Rh)bull Four sources in irradiator bull Select source and move to working position
return to storage position using special rodbull Transfer container for temporary storage of
sources bull Red light signal of source working position
UPGD-2M-DGAMMA BEAM IRRADIATOR
Physical characteristicsRange of reproduced dose rate bull 05 μSvh divide 50 mSvh (50 μRh divide 5 Rh)
Maximum activity of source bull 2times1011 Bq (50 Ci) Cs-137
Overall dimensionsbull Irradiator 800times500times500 mmbull Guide rails length 30 mbull Height 16 mbull Weight not more than 700 kgbull Required room dimensions not less than 7x3x3 m
Electrical characteristicsPower supply bull 220 V 50 Hz
UPGD-2M-D
Reference standards IEC 60846 IEC 61526 IEC 61066
SPC ldquoDozardquo
78 79
Contents
MEASURING UNITS
DBG-S11D wide range gamma area monitor 40
UDKS-100 gamma and X-ray area monitor 41
UDMN-100 neutron area monitor 41
ALARM UNITS
BAS-2 ldquoMICROrdquo external visual alarm 42
BZS-2 ldquoMicrordquo external audible alarm 42
Illuminated warning signs 43
ldquoImpulsrdquo external display unit 43
UIM-3D area monitor count rate meter 44
DKG-05D personal gamma dosimeter 46
DVS-02D gamma-neutron personal electronic dosimeter 47
DVGI-8D new pen-type personal ionization chamber dosimeters 48
DKG-02U ldquoARBITERrdquo wide range gamma-dosimeter 49
DKG-07D ldquoDROZDrdquo gamma-dosimeter 50
MKS-15D ldquoSNEGIRrdquo multi ndash purpose radiation survey meter 51
SRPS-05D gamma monitor 52
DOZA-TLD multipurpose TLD system 53
DKS-96 universal radiation survey meter 54
EXTERNAL PROBES ALPHA
Alpha BDZA-96 55
Alpha BDZA-96B 55
Alpha BDZA-96M 55
Alpha BDZA-96S 55
Alpha BDZA-96T 55
EXTERNAL PROBES BETA
Beta BDZB-96 56
Beta BDZB-99 56
Beta BDZB-96B 56
Beta BDZB-96S 56
EXTERNAL PROBES GAMMA
Gamma BDKS-96B 57
Gamma and beta BDKS-96S 57
Gamma BDMG-96 57
EXTERNAL PROBES GAMMA
Gamma-search BDVG-96 58
Gamma-search BDPG-96 58
ContentsRadiation monitoring systemldquoPELIKANrdquo Radiation monitoring system (RMS) 6
BDMG-101 high range gamma area monitor 10
DBG-S11D wide range gamma area monitor 11
BDRG-52 high range gamma area monitor for accident and post-accident conditions 12
UDGP-01 Liquid technological environments monitor 13
UDMN-100 neutron area monitor 14
UDKG-100 Wel Liquid gamma monitor 14
BOP-1M data processing and transmission unit 15
UDA-1AB particulate monitor 16
UDG-1B noble gas monitor 17
UDG-03D noble gas monitor 18
UDI-1B iodine monitor 19
UDGB-01 noble gasesH-3C-14 monitor 20
UDGP-01 steam generator leakage monitor 21
UPPVM air flow parameters monitor 22
ldquoIMPULSrdquo external display unit 23
BI-2 remote display amp alarm unit 24
BASBAS-1s external alarm 25
SKGAV stack monitor 26
RMS software 28
RMS workstation ndash operator console 29
Configurator software 29
RM RACK radiation monitoring rack 30
SRKS-01D criticality accident alarm system 32
ldquoATLANT-Mrdquo environmental radiation monitoring system 34
ldquoBREEZErdquo high-volume air sampler 35
ldquoGAMMA-SENSORrdquo gamma-survey system 36
Radiation monitoring equipmentAREA MONITOR ldquoFREGATrdquo 38
BPI-1D local display unit 39
80
Gamma-search BDPG-96M 58
Gamma BDKG-96 stainless steel casing for geologic applications well logging 59
EXTERNAL PROBES NEUTRON
Neutron BDMN-96 59
Neutron-search BDKN-96 59
RZB-05D Hand-foot-clothing monitor 60
RZBA-04-04M whole body contamination monitor 61
RZA-05D alpha hand-monitor 62
UMF-2000 low level alpha- beta- counter 63
DRK dose area product meter 64
ldquoPROGRESS-BETArdquo scintillation beta spectrometer 65
ldquoPROGRESS-GAMMArdquo scintillation gamma spectrometer 66
ldquoPROGRESS-G(P)rdquo portable scintillation gamma spectrometer 67
ldquoPROGRESS-ARrdquo alpha radiometer 68
ldquoPROGRESSrdquo whole body counter 69
MKG-01D ldquoSADOVNIKrdquo spectrometry system 70
MKS-01A ldquoMULTIRAD-ASrdquo alpha spectrometer 71
UCRV-2 airflow monitor 72
PVP-06 portable air sampler 73
ldquoALPHARAD PLUSrdquo radon thoron amp their progeny monitor 74
UPG-P desktop gamma beam irradiator 75
UPGD-2M-D gamma beam irradiator 76
UKPN-2M-D neutron beam irradiator 77
Radiation monitoring system SPC ldquoDozardquo
22 23
Physical characteristicsLength of communication cablebull up to 1200 m
Character height bull ldquoImpuls-910-Rrdquo 100 mmbull ldquoImpuls-915-D4Srdquo 150 mmbull ldquoImpuls-927-D4Srdquo 270 mm
Operating temperature rangebull ldquoImpuls-910-Rrdquo 0 divide +50 ordmCbull ldquoImpuls-915-D4Srdquo ldquo-927-D4Srdquo minus 40 divide +50 ordmC
Electrical characteristicsbull Power supply 220 V 50 Hz
Mechanical characteristicsProtection index bull ldquoImpuls-910-R IP 44bull ldquoImpuls -915-D4Srdquo ldquo-927-D4Srdquo IP 65
Overall dimensions weight bull ldquoImpuls-910-Rrdquo 400times160times60 mm 3 kgbull ldquoImpuls -915-D4Srdquo 815times250times80 mm 5 kgbull ldquoImpuls -927-D4Srdquo 1250times330times80 mm 5 kg
ldquoIMPULSrdquoEXTERNAL DISPLAY UNIT
Display of data received from monitors of RMS
External display unit ldquoImpuls-910-Rrdquo
Reference standards EMC IEC 61010 IEC 61000-6-2 Seismic IEC 60980
Continuous monitoring of the flow rate temperature and humidity of the gas flowbull Definition of air volume flow rate in stacks taking
into account temperature and humidity of the air
UPPVM AIR FLOW PARAMETERS MONITOR
Physical characteristicsMeasurement range bull air flow velocity 1 divide 20 msbull air temperature 0 divide +80 ordmСbull air humidity 10 divide 95
Electrical characteristicsbull Power supply 220 V 50 Hz bull Interfaces RS-232 Ethernet
Mechanical characteristicsProtection index bull BSPP-1st BSPP-1tv BOP-1s IP 65bull PP-st IPTV IP 54bull Paint decontaminable
Overall dimensions weight bull air velocity probe PP-st 60times38times136 mm 015 kgbull Interface block BSPP-1st 125times155times73 mm 07 kgbull air temperature and relative humidity probe
IPTV-056-A 333times100times60 mm 07 kgbull Interface block BSPP-1tv 125times155times73 mm 07 kgbull Data processing and transmission unit BOP-1s
280x233x111 mm 8 kg
Reference standards Nuclear ISO 2889 EMC IEC 61010 IEC 61000-6-2 Seismic IEC 60980
BOP-1S
Radiation monitoring system SPC ldquoDozardquo
24 25
BASBAS-1S EXTERNAL ALARM
Generation of audible and visual signals of the excess of preset thresholds RMS monitorsbull Audible alarm 80 divide 100 dBA at distance 1 mbull Visual alarm green yellow red
Distance from RMS monitorbull BAS up to 20 mbull BAS-1s up to 1200 m
Power supply bull 220 V 50 Hz
Overall dimensions weight bull BAS 145times108times460 mm 18 kg bull BAS-1s 166times109times466 mm 18 kg
Reference standards EMC IEC 61010 IEC 61000-6-2 Seismic IEC 60980
Physical characteristicsLength of communication cablebull up to 1200 m
Displayed page size bull 4 lines of 20 characters
Volume of loaded information bull 10 pages
Change of pagesbull programmed or by pressing a button
Operating temperature rangebull minus 40 divide +50 ordmC
Electrical characteristicsbull Power supply 9 divide 18 VDCbull Interfaces RS-485
Mechanical characteristicsbull Protection index IP 65bull Overall dimensions weight 222times164times73 mm
40 kg
BI-2 REMOTE DISPLAY amp ALARM UNIT
bull Display of data received from monitors of RMSbull Audible and visual alarms on exceeding preset
thresholds of the RMS equipment bull Individual threshold setting for each measure-
ment channelbull Audible alarm 80 divide 100 dB at a distance of 1 m bull Visual alarm red yellow green
Reference standards EMC IEC 61010 IEC 61000-6-2 Seismic IEC 60980
Radiation monitoring system SPC ldquoDozardquo
2726
Electrical characteristicsbull Power supply 220 V 50 Hz bull Interfaces RS-232 RS-485 Ethernetbull programmable relay output (SPDT relay)
Alarmbull Sound alarm 80 divide 100 dBA at distance 1 mbull Visual alarm green yellow redbull Connection of the external alarm unit ldquoBASrdquo type
Related monitors and equipmentsbull UDA-1AB particulate monitorbull UDG-1B noble gas monitorbull UDI-1B iodine monitorbull UPPVM air flow parameters monitorbull Sampling and sample separation rack
Air flow parameters monitor rack
Reference standards Nuclear IEC 60761 IEC 61171 IEC 61172 IEC 62302 ISO 2889 EMC IEC 61010 IEC 61000-6-2 Seismic IEC 60980
Sampling and sample separation rack
Continuous monitoring of radioactivity in gaseous effluentsbull Automatic monitoring of the alpha- and beta-
radioactive aerosol noble gas and radioiodine concentrations in the air in ventilation ducts and stacks
bull Monitoring of the flow rate temperature and humidity of the gas flow
bull Separation of gaseous effluent into targeted fractions by means of a two-stage filter
bull Reversion of gas after analysis to the ventilation system
Physical characteristics
Particulate (UDA-1AB)bull Silicon specrometric detectors (2 pcs for measure-
ment and for gamma-background compensation) bull Filter tape types LFAS FSLWbull Tape consumption (when continuous operation)
10 m50 days
Measurement range bull Alpha 10-2 divide 2105 Bqm3 bull Beta 10-1 divide 106 Bqm3
Energy range bull Alpha 30 divide 90 MeV bull Beta 005 divide 30 MeV
Noble gas (UDG-1B)bull silicon detectors (2 pcs for measurement and for
gamma-background compensation)
Measurement range bull 104 divide 6109 Bqm3
Energy range bull 008 divide 30 MeV
Iodine (UDI-1B)bull scintillation detectors CsI(Tl) (2 pcs for measure-
ment and for background compensation)
SKGAV STACK MONITOR
Particulate noble gas and iodine monitors rack
Measurement range bull 37 divide 37105 Bqm3
Energy range bull 015 divide 30 MeV
Air flow parameters (UPPVM)Measurement range bull air flow velocity 1 divide 20 msbull air temperature 0 divide +80 ordmСbull air humidity 10 divide 95
Radiation monitoring system SPC ldquoDozardquo
28 29
CONFIGURATOR SOFTWAREMaintenance and set-up softwarebull Set-up and verify RMS monitorsbull Control testing adjustment and repair of RMS
monitorsbull Monitors measurement results archive receive
and View bull Communication through RS-232
RMS WORKSTATION ndash OPERATOR CONSOLEOrganization of interaction of the RMS Server and Monitors
Single monitor console includes vandal-proof key-board amp UPS
Reference standard IEC 61559-1 IEC 61559-2
RMS SOFTWAREData acquisition storing and visual representation RMS monitors measurement resultsbull Ethernet IEEE 8023 networkbull Clientserver architecturebull TCPIP protocolbull Oracle based Data Basebull Supremal by means InSat MasterSCADA
Radiation monitoring system SPC ldquoDozardquo
30 31
Delivery setComposition and modification depend on the tasks to be solved using the RM Rack
The rack which is an integral part of RM Rack accommodatesbull Monitors UDA-1AB UDG-1B UDG-03D UDI-1B
UDGB-01Tbull DBG-S11D Wide range gamma area monitor
BDMG-101 High range gamma area monitor UDMN-100 Neutron area monitor BDRG-52R High range gamma area monitor
bull BI-2 Remote display amp alarm unitbull Pump unit BN-01bull Data processing and transmission unit BOP-1Mbull External alarm BAS or BAS-1sbull Equipment of sampling line (flow meters ball
valves filter holder piping solenoid valve)bull Switchboard (intended for switching of all equip-
ment and transfer of data to the upper level via the unified communication channel)
RM RACK RADIATION MONITORING RACK
The radiation monitoring rack (RM Rack) is designed for continuous monitoring of radiation parameters in premises and technological systems at nuclear facil-ities RM Rack can be used as a structural element of the lower-level of RMS at nuclear power plants and other nuclear facilities that involved in obtaining processing use and storage of radioactive materials
FeaturesContinuous automatic monitoring of the alpha- and beta- radioactive aerosol beta-emitting radioactive gases and radioiodine concentrations in the working air and in the air in stacks and others radiation parameters in the facilities
The stand providesbull Primary processing storage and transmission of
measured and related data into the information channel based on the Ethernet IEEE 8023 inter-face (TCPIP protocol)
bull Transfer of required data to the location where the equipment is installed via technological channels based on RS-232 interface
bull Generation of audible and visual warning alarm signals when the preset thresholds are exceeded
bull Display of received data on the LCD
Radiation monitoring system SPC ldquoDozardquo
32 33Reference standards IEC 60860 ANSIANS-83 ISO 7753
Purposebull Detection and recording of criticality accident
(CA) by measuring the absorbed dose rate of gamma-neutron radiation in the premises of monitored object its comparison with a threshold value and generation of audible and visual signals
bull Automatic collection processing storage and display of measurement data and related infor-mation as visual and graphical representation for operators of nuclear safety service
Functions of the systembull Detection and recording of CA events by con-
tinuous measurement of absorbed dose rate of gamma radiation comparison of measured values with preset thresholds generation of signals to activate the alarm
bull Activation of audible visual alarmbull In the event of CA turning on warning signals
ldquoDO NOT ENTERrdquo at illuminated information pan-els placed at the entrances to the controlled area
Featuresbull Data can be transferred to external data commu-
nication channel using RS-485 interface (DiBus data exchange protocol)
bull Automatic self-testing of detection units BR-04D with display of information about the type of fault
bull Possibility for connecting additional a detection and alarm units
bull Ability to function in general regardless of the functioning of components within the agreed scope of nuclear safety tasks
bull Radiation hardness up to 100 Gy
SRKS-01DCRITICALITY ACCIDENT ALARM SYSTEM
Features of softwarebull Collection of information via RS-485 network
displaying it on the PC monitor transmission to remote users archiving and storage
bull Status monitoring and display of values measured by BR-04D and DBG-S11D in locations as per layout of premises
bull Access to archived data with possibility to gener-ate reports for periods determined by operator
bull Maintenance and archiving of a log of dosimetric measurements data and events along with their time stamps
bull Possibility to transfer data to external users via Ethernet network for integrating of CA into higher level systems
Basic complete setLower level bull Control unit with power supplybull BR-04D detection unitsbull BZS-01D audible alarm unitsbull BSS-01D visual alarm unitsbull SIT-01D illuminated warning signsbull PBZ panels for muting audible alarmbull Network communication module
Additional lower layer devicesbull DBG-S11D wide range gamma area monitor
Upper layer bull CDP central display panelbull Service workstation
RS-485
RS-485
RS-4
85
Audible alarm units BZS-01D
Illuminated warning signs SIT-01D
Detection units BR-04D
Network communication
moduleDBG-S11D wide range gamma area monitor
Panels for muting audible alarm
Control unit with power supply
Visual alarm units BSS-01D
RS-485
RS-485
RS-4
85
Audible alarm units BZS-01D
Illuminated warning signs SIT-01D
Detection units BR-04D
Network communication
moduleDBG-S11D wide range gamma area monitor
Panels for muting audible alarm
Control unit with pow-er supply
Visual alarm units BSS-01D
RS-485
RS-4
85
Audible alarm units BZS-01D
Illuminated warning signs SIT-01D
Detection units BR-04D
Network communication
moduleDBG-S11D wide range gamma area monitor
Panels for muting audible alarm
Control unit with power supply
Visual alarm units BSS-01D
RS-485
RS-485
RS-4
85
Audible alarm units BZS-01D
Illuminated warning signs SIT-01D
Detection units BR-04D
Network communication
moduleDBG-S11D wide range gamma area monitor
Panels for muting audible alarm
Control unit with power supply
Visual alarm units BSS-01D
Ethernet
Central display panel Service workstation
RS-485
RS-485
RS-4
85
BZS-01D audible alarm units
SIT-01D illuminated warning signs
BR-04D detection units
Network communication
moduleDBG-S11D wide range gamma area monitor
PBZ panels for muting audible alarm
Control unit with power supply
BSS-01D visual alarm units
Radiation monitoring system SPC ldquoDozardquo
34 35
ldquoBREEZErdquoHIGH-VOLUME AIR SAMPLER
Physical characteristicsbull Measurement range of air flow rate
250 divide 1200 m3hbull Continuous operation time not less than 24 h
Filter materialsbull High-purity glass fiberbull Pure quartz or cellulosebull Filter fabric FPP-15-15
Electrical characteristicsPower supply bull 220380 V 50 Hz
Interfaces bull RS-485bull Ethernetbull GSMGPRS (option)
Environmental characteristicsTemperature range bull minus 40 divide + 40 ordmC
Relative humidity limit at 35 ordmC bull 95
Atmospheric pressure range bull 840 divide 1067 kPa
Versionsbull Standalone unit bull Part of Environmental Radiation Monitoring
System (ERMS)
Type of detection unitsbull Beta block BDZB-100Lbull DBG-S11D wide range gamma area monitorbull Scintillation spectrometric block
The motor of Air Sampler is controlled by an electronic flow sensor that detects changes in the operators pre-set flow rate caused by changes in temperature barometric pressure and pressure drop due to dust loading on filter media It compensates for these changes by adjusting the motor speed to maintain the pre-set flow ratebull Measurement of parameters of ionizing radiation bull Standalone mode of operation or as the part
of Environmental Radiation Monitoring System (ERMS)
Purposebull Environmental Radiation Monitoring System
(ERMS) in the control and buffer areas of the radia-tion and nuclear facilities
Referencesbull Since the year 2000 the system is successfully
operating the ERMSs at 8 Russian nuclear power plants (about 180 monitoring stations)
bull Since the year 2005 the ERMS is operating in the Moscow (about 40 monitoring stations)
bull Since the year 2005 the regional ERMS is under operation in several Russian Federation regions
Basic complete setMonitoring stations bull Data processing and transmission unit BOP-1TA bull Gamma area monitor DBG-S11D
Central data processing station (CDPS)bull Data processing and transmission unit BOP-1TAbull Server
By requestbull Emergency Response and Crisis Management
Centers for enterprisesbull Regional Emergency Response and Crisis Manage-
ment Centersbull rdquoBreezerdquo High-Volume Air Samplerbull Mobile lab with gamma-survey system rdquoGammandash
sensorrdquo
ldquoATLANT-MrdquoENVIRONMENTAL RADIATION MONITORING SYSTEM
Monitoring system for the continuous radiation monitoring of territories and facilities with the data transmission GSMGPRS network
Data transmission bull GSMGPRS
Power supply bull 220 V 50 Hz
Continuous autonomous operation (at 20 ordmC)bull From built-in battery not less than 5 hoursbull From external battery not less than 24 hours
Operation temperature bull Minus 40 divide +50 ordmC
Operation humidity bull Up to 98
Protection bull IP65
Reference standards Nuclear IEC 61017-11991 IEC 61017-21994
36
Radiation Monitoring Equipment
bull Localization of radioactive contaminationsbull Database with dose rate contaminations
spectra measurement date amp time coordi-nates
bull Work as part of mobile laboratory or as part of Environmental Radiation Monitoring System with real-time data transfer
Physical characteristicsDetector bull Scintillation NaI (Tl) GM counters
Measurement rangebull 01 ndash 107 μSvh
Energy range bull 005 ndash 3 MeV
Operation temperature range bull minus 10 divide +50 ordmС
Electrical characteristics bull Power supply 220 V 50 Hz
ldquoGAMMAndashSENSORrdquoGAMMA-SURVEY SYSTEM
SPC ldquoDozardquoRadiation monitoring equipment
38 39
AREA MONITOR ldquoFREGATrdquoArea Monitor ldquoFregatrdquo is designed for building rela-tively simple and inexpensive radiation monitoring systems at such facilities as radionuclide sources storage areas isotope products warehouses nuclear medicine departments PET centers calibration laboratories where sources of ionizing radiation are used etc
Small scale automated radiation monitoring systems built with ldquoFregatrdquo components featuring audible and visual alarms are matched suitable to meet the regulatory radiation safety requirements
Area monitor ldquoFregatrdquo requires virtually no adjust-ment it is simple and convenient for installation and operation
BPI-1D LOCAL DISPLAY UNIT
Display of monitored parameters values received from external measuring devices
Purposebull Processing and display of values of monitored
parameters on information panel bull Comparison of values of monitored parameters
with thresholdsbull Transfer of monitored parametersrsquo values to
networkbull Generation of alarm in case of exceeding of preset
thresholds including external alarm devices
FeaturesTesting the unit and connected devicesbull Visually on the panelbull Using adjustment software when connected to
PC via USB
Automatic self-testing
The panel displays the following informationbull Diagnostic information about the status of con-
nected devicesbull Current date and timebull Values of measured parametersbull Position of measured values with respect to the
thresholds in the form of scales with green yellow and red zones
bull Time history (trend) for each measured value
Physical characteristicsTemperature range bull minus 10 divide + 50 ordmC
Maximum number of connected devicesbull measuring devices 15bull external audible and visual alarm 15
Display diagonal bull 152 cm (6)
Electrical characteristicsbull Interfaces RS-485bull Power supply 220 V 50 Hz 12 divide 24 V
Mechanical characteristicsbull Protection index IP54bull Paint decontaminable
Overall dimensions weightbull 296x248x118 mm 5 kg
DBG-S11D wide range gamma area monitor
UDMN-100 neutron area monitor
Ethernet RS-485
UDKS-100 gamma and X-ray area monitor
BPI-1D Local display unit
BAS-2 ldquoMicrordquo external visual alarm
BZS-2 ldquoMicrordquo external audible alarm
ldquoImpulsrdquo external display unit
Service workstation
Illuminated warning signs
SPC ldquoDozardquoRadiation monitoring equipment
4140
Continuous automatic monitoring of the gamma- X-ray ambient dose equivalent rate
Physical characteristicsbull Detector tissue-equivalent plastic scintillator
Oslash 45times20 mm
Measurement range bull Dose rate measurement range 01 μSvh divide 1 Svh bull Energy range 0015 divide 10 MeV
Mechanical characteristicsbull Protection index IP65bull Paint decontaminable
Overall dimensions weightbull Oslash72times265 mm 15 kg
UDKS-100 GAMMA AND X-RAY AREA MONITOR
UDMN-100 NEUTRON AREA MONITOR
Physical characteristicsbull detector ndash scintillator ZnS(Ag) Li-6
Measurement range bull 01 μSvh divide 01 Svh
Energy range bull 0025 eV divide 100 MeV
Temperature range bull minus 45 divide +50 ordmC
Electrical characteristicsbull Interfaces RS-485
Mechanical characteristicsbull Protection index IP 65bull Paint decontaminable
Overall dimensions weight bull 428times258times347 mm 115 kg
Continuous automatic monitoring of the neutron-radiations ambient dose equivalent ratebull Spherical polyethylene moderator Oslash 239 mm
MEASURING UNITS
DBG-S11D WIDE RANGE GAMMA AREA MONITOR
Continuous automatic monitoring of the gamma- ambient dose equivalent rate
Physical characteristicsbull Detector ndash GM counters
Measurement rangebull DBG-S11D 01 μSvh divide 10 mSvhbull DBG-S11D-01 01 μSvh divide 10 Svhbull DBG-S11D-02 01 μSvh divide 100 Svh
Energy rangebull 005 divide 30 MeV
Temperature range bull minus 40 divide +50 ordmC
Electrical characteristicsbull Interfaces RS-485 USB
Mechanical characteristicsbull Protection index IP 68bull Paint decontaminable
Overall dimensions weightbull DBG-S11D Oslash 68times141 mm 065 kg bull DBG-S11D-01 Oslash 68times179 mm 07 kgbull DBG-S11D-02 Oslash 68times179 mm 07 kg
Versionsbull DBG-S11Dbull DBG-S11D-01bull DBG-S11D-02
Reference standards Nuclear IEC 60846 IEC 60532 EMC IEC 61010 IEC 61000-6-2 Seismic IEC 60980
SPC ldquoDozardquoRadiation monitoring equipment
4342
ALARM UNITS
Generation visual signals of the excess of preset thresholds
Physical characteristicsLength of communication cablebull up to 1200 mbull Alarm Visual alarm green yellow red
Electrical characteristicsbull Power supply +12 V
Mechanical characteristicsbull Protection index IP 23
Overall dimensions weight 160times84times41 mm 02 kg
BAS-2 ldquoMICROrdquo EXTERNAL VISUAL ALARM
Generation audible signals of the excess of preset thresholds
Physical characteristicsLength of communication cablebull up to 1200 mbull Audible alarm 80 divide 100 dB at a distance of 1 m
Electrical characteristicsbull Power supply +12 V
Mechanical characteristicsbull Protection index IP 23
Overall dimensions weight 160times84times41 mm 02 kg
BZS-2 ldquoMICROrdquo EXTERNAL AUDIBLE ALARM
Physical characteristicsLength of communication cablebull up to 1200 m
Electrical characteristicsbull Power supply 220 V 50 Hz
Mechanical characteristicsbull Protection index IP 23
Overall dimensions weight bull 330times110times20 mm 05 kg
Physical characteristicsLength of communication cablebull up to 1200 m
Character height bull ldquoImpuls-910-Rrdquo 100 mmbull ldquoImpuls-915-D4Srdquo 150 mmbull ldquoImpuls-927-D4Srdquo 270 mm
Operating temperature rangebull ldquoImpuls-910-Rrdquo 0 divide +50 degCbull ldquoImpuls-915-D4Srdquo ldquo-727-D4Srdquo minus 40 divide +50 degC
Electrical characteristicsbull Power supply 220 V 50 Hz
Mechanical characteristicsProtection index bull ldquoImpuls-910-R IP 44bull ldquoImpuls-915-D4Srdquo ldquo-727-D4Srdquo IP 65
Overall dimensions weight bull ldquoImpuls-910-Rrdquo 400times160times60 mm 3 kgbull ldquoImpuls-915-D4Srdquo 815times250times80 mm 5 kgbull ldquoImpuls-927-D4Srdquo 1250times330times80 mm 5 kg
ILLUMINATED WARNING SIGNS
ldquoIMPULSrdquo EXTERNAL DISPLAY UNIT
SPC ldquoDozardquoRadiation monitoring equipment
4544
Individual threshold setting for each measurement channel
Continuous area and process monitoring
Collect amp display data from two measurement chan-nels (units with RS-485 or analog pulses)
Audible and visual alarms on exceeding preset thresholds or status of connected devices
Individual threshold setting for each measurement channel
Switching on the external alarm or executive devices when any threshold is exceeded
The wide panel displays the following information bull Values of measured parameters as min-1∙cm-2
s-1∙cm-2 μSvhbull Diagnostic information about the status of con-
nected devicesbull Current date and timebull Position of measured values with respect to the
thresholds in the form of scales with green yellow and red zones
bull Time history (trend) for each measured value
Physical characteristics Measurement range bull Count rate up to 107 CPM (170 kHz)
Operating temperature range bull minus 20 divide +50 ordmC
Electrical characteristics bull Power supply 220 V bull Interfaces USB
Mechanical characteristics bull Protection index IP 65 bull Overall dimensions weight 222times164times73 mm
40 kg
UIM-3D AREA MONITOR COUNT RATE METER
Measurement of alpha radiation flux density
Detector unit BDZA-100 (70 cm2) Measurement range 01 divide 104 min-1∙cm-2
Detector unit BDZA-100B (300 cm2) Measurement range 01 divide 2103 min-1∙cm-2
Measurement of beta radiation flux density
Detector unit BDZB-100 (28 cm2) Measurement range 10 divide 105 min-1∙cm-2
Detector unit BDZB-100L (30 cm2) Measurement range 10 divide 104 min-1∙cm-2
Detector unit BDZB-11D (84 cm2) Measurement range 5 divide 15∙104 min-1∙m-2
OPTIONAL PROBESMeasurement of gamma radiation flux density
Detector units BDEG-03 Measurement range 4 divide 2000 s-1∙cm-2
Detector unit UDKG-100 for operation in the rocks ore liquid media and sludge Measurement range 40 divide 8000 s-1∙cm-2
Measurement of the ambient dose equivalent rate
Detector unit DBG-S11D Measurement range 01 μSvh divide 100 Svh
Measurement of neutron radiation ambient dose equivalent rate
Detector unit BDMN-100 Measurement range 01 μSvh divide 01 Svh
SPC ldquoDozardquoRadiation monitoring equipment
46 47Reference standards Nuclear IEC 61526
Measurement of gamma-radiation personal dose equivalent Hp(10)bull Stand-alone dosimeter or composed of dosimetric
system onebull Audible and visual alarmbull Large memory dose accumulation historiesbull Exclusion of unauthorized intervention in dosim-
etry operation
DKG-05D PERSONAL GAMMA DOSIMETER
Physical characteristicsDetectors bull Silicon
Measurement range bull Dose rate 1 μSvh divide 10 Svhbull Dose 01 μSv divide 15 Sv
Energy range bull 005 divide 30 MeV
Electrical characteristicsbull Power supply rechargeable NiMH battery 1
alcaline battery (type AAA)
Operation timebull Till recharging not less 400 hoursbull With one set batteries not less 1000 hours
Mechanical characteristicsOverall dimensions weight bull 47times26times87 mm (with clip) 70 g
Environmental characteristicsbull IP65bull Temperature range minus 20 divide +45 ordmCbull Humidity up to 98 at 35 ordmCbull Shock vibration and drop resistant
Alarmbull Excess of alarm thresholdsbull Warnings of self-test failure and battery discharge bull Audible alarm 80 dB at 40 cmbull Visual alarm blinking LED
Relative equipmentbull One dosimeter charger ZU-1Mbull Chargestorage cassetes KZU-28KZU-56bull ldquoSmart chargingrdquo feature extends battery life timebull DKG-05D reader US-05bull DKG-05D system reader DVS-01D
Reader-PC interfacebull US-05 USB bull DVS-01D Ethernet
KZU-28
Physical characteristicsDetectors bull Silicon Li-6
Gamma measurement range bull Dose rate 1 μSvh divide 10 Svhbull Dose 01 μSv divide 15 Sv
Gamma energy range bull 005 divide 60 MeV
Neutron measurement range bull Dose rate 1 μSvh divide 2 Svhbull Dose 20 μSv divide 15 Sv
Neutron energy range bull 0025 eV divide 20 MeV
Electrical characteristicsPower supply bull Rechargeable NiMH batterybull Operatiion time till recharging not less 200 hours
Mechanical characteristicsOverall dimensions weight bull 47times26times87 mm (with clip) 70 g
Environmental characteristicsbull IP65bull Temperature range minus 20 divide +40 ordmCbull Humidity up to 75 at 30 ordmCbull Shock vibration and drop resistant
Alarmbull Excess of alarm thresholds bull Warnings of self-test failure and battery discharge bull Audible alarm 80 dB at 40 cmbull Visual alarm blinking LED
Relative equipmentbull One dosimeter charger ZU-1Mbull Chargestorage cassetes KZU-28 KZU-56bull ldquoSmart chargingrdquo feature extends battery life timebull DVS-02D reader UZS-01Sbull DVS-02D system reader DVS-01D
Reader-PC interfacebull UZS-01S USB bull DVS-01D Ethernet
UZS-01DReference standards Nuclear IEC 61526
DVS-02D GAMMA-NEUTRON PERSONAL ELECTRONIC DOSIMETER
Measurement of gamma- and neutron radiations personal dose equivalent Hp(10)bull Stand-alone dosimeter or composed of dosimetric
system onebull Audible and visual alarmbull Large memory dose accumulation historiesbull Exclusion of unauthorized intervention in dosim-
etry operationbull Both albedo thermal neutrons and intermediate
fast neutrons registrationbull Usable in the fields of Pu(Be) Po(Be) Cf and other
neutron sources as well as near nuclear reactors without neutron spectrum estimation
SPC ldquoDozardquoRadiation monitoring equipment
48 49
Dosimeters DVG-03D
DVGI-8D NEW PEN-TYPE PERSONAL IONIZATION CHAMBER DOSIMETERS
Measurement of personal dose equivalent Hp(10) of gamma and X-ray radiationbull Hp(10) of continuous and pulsed gamma and
X-ray radiation bull Electronic reader KSU-1bull Dosimeter DVG-03D with electronic ID bull Personal dose histories in the readerrsquos memorybull Readerrsquos connection with PC for database main-
tenance
Physical characteristicsDetector bull Ionization chamber
Measurement range bull 001 mSv divide 25 mSv
Energy range bull 0015 divide 25 MeV
Temperature range bull Reader KSU-1 +10 divide +50 ordmСbull Dosimeter DVG-03D minus 40 divide +50 ordmС
Electrical characteristicsPower supply bull Reader KSU-1 220 V 50 Hz built-in batteries bull Dosimeter DVG-03D four batteries CR 1025 bull Batteries life 3 yearsbull Readers interfaces RS-232USB 20
Mechanical characteristicsOverall dimensions weightbull Dosimeter DVG-03D Oslash 18times126 mm 005 kgbull Reader KSU-1 235times232times125 mm 28 kg
Reference standards Nuclear IEC 62387-1
DKG-02U ldquoARBITERrdquo WIDE RANGE GAMMA-DOSIMETER
Physical characteristicsDetectors bull GM counters
Measurement rangebull Dose-rate 01 μSvh divide 3 Svhbull Dose 1 μSv divide 100 Sv
Energy range bull 005 divide 3 MeV
Electrical characteristicsbull Power supply 2 alcaline batteries (type AA)bull Batteries life not less 200 hours
Mechanical characteristicsOverall dimensions weight bull 152times82times32 mm 03 kg
Environmental characteristicsbull Temperature range minus 20 divide +50 ordmCbull Humidity up to 90 at +25 ordmCbull Shock vibration and drop resistant
Reference standards Nuclear IEC 60846
Measurement of gamma radiation ambient equiva-lent dose H(10) and dose rate H(10)bull Audible signals (clicks) for radiation condition
estimationbull Analog scale for search modebull Audible and visual alarms of the excess of preset
dose and dose rate thresholds bull Shock-resistant water-proof easy decontamina-
tion casebull 100 measurement results memory with date and
time of measurementbull Indication of total dose accumulated during
exploitation time bull Indication of measurement result statistical
uncertainty
SPC ldquoDozardquoRadiation monitoring equipment
50 51
Physical characteristicsDetectors bull GM counter
Measurement rangebull Dose-rate 01 μSvh divide 3 mSvhbull Dose 1 μSv divide 02 Sv
Energy range bull 005 divide 3 MeV
Temperature range bull Minus 20 divide +50 ordmC
Electrical characteristicsbull Power supply 2 alcaline batteries 15 V (type AA)bull Batteries life not less 200 hours
Mechanical characteristicsOverall dimensions weight bull 122times74times29 mm 025 kg
Reference standards Nuclear IEC 60846
DKG-07D ldquoDROZDrdquoGAMMA-DOSIMETER
Measurement of gamma radiation ambient equiva-lent dose H(10) and dose rate H(10)bull Two independent measurement channels dose
and dose ratebull Audible signals (clicks) for radiation condition
estimationbull Continuous measurement with updating meas-
urement resultbull Measurement result can be obtained with any
desired statistical uncertainty (error)bull Automatic restart when radiation level sharply
changesbull Indication of statistical uncertainty (error) during
measurement process
Continuous measurement with updating measure-ment result
Automatic restart when radiation level sharply changes bull Gamma dose H(10) and dose-rate H(10) meas-
urementbull Beta and gamma contamination surveybull Indication of statistical uncertainty during the
measurementbull Continuous measurement with accuracy increas-
ing with time bull Automatic restart triggered by change of gamma
dose-ratebull Compensation of gamma count rate while meas-
uring beta radiationbull Indication of battery charge levelbull Audible signal of the excess of preset threshold
Physical characteristicsDetectors bull GM counter
Measurement range bull Dose-rate 01 microSvh divide 20 mSvhbull Dose 1 microSv divide 100 Svbull Beta flux density (for Sr-90+Y-90)
10 divide 105 cm-2 min-1
Energy range bull Gamma 005 divide 3 MeVbull Beta 01 divide 3 MeV
Temperature range bull Minus 20 divide +50 ordmC
MKS-15D ldquoSnegirrdquo backside
MKS-15D ldquoSNEGIRrdquoMULTI ndash PURPOSE RADIATION SURVEY METER
Reference standards Nuclear IEC 60846 IEC 60325
Electrical characteristicsbull Power supply 2 alcaline batteries (type AA)bull Battery life not less 400 hours
Mechanical characteristicsOverall dimensions weight bull 124times72times35 mm 035 kg
SPC ldquoDozardquoRadiation monitoring equipment
52 53
Physical characteristicsDetectorbull GM counter
Measurement range bull 01 μSvh divide 20 mSvh
Energy range bull 005 divide 30 MeV
Threshold setting range bull 03 μSvh divide 20 mSvh
Step change of the thresholdbull In the range 03 divide 10 μSvh with the step
001 μSvhbull In the range 10 divide 100 μSvh with the step
01 μSvhbull In the range 100 divide 2000 μSvh with the step
10 μSvh
Electrical characteristicsPower supply bull 220 V 50 Hz bull Relay output
Mechanical characteristicsProtection index bull IP 40
Overall dimensions weight bull 226times120times75 mm 07 kg
Alarmbull Sound alarm 80 divide 100 dBA at distance 1 mbull Visual alarm redbull Connection of the external alarm signaling unit
Reference standards Nuclear IEC 60846 IEC 60532
Continuous automatic monitoring of the ambient dose equivalent rate bull Measurement of gamma dose rate H(10)bull Audible and visual alarm signals for preset
thresholdsbull Switching on the external signaling or executive
devices
SRPS-05D GAMMA MONITOR
Measurement ofbull Gamma and X-ray personal dose equivalent
Hp(10)bull Neutron personal dose equivalent Hp(10)bull Lens dose equivalent Hp(3)bull Skin dose equivalent Hp(007)bull TLD reader day-to-day tests using built-in LEDbull No needs nitrogen for heating
Physical charachteristicsDetectors bull 7LiF Mg Ti (gamma beta)bull 6LiF Mg Ti (neutron)
Gamma and X-ray Hp(10) Measurement range bull 500 μSv divide 10 Sv
Energy range bull 0015 divide 30 MeV
Neutron Hp(10)Measurement range bull 01 mSv divide 100 mSv
Energy range bull 0025 eV divide 10 MeV
Beta and photons Hp(007) Hp(3) Measurement range bull 2 mSv divide 100 Sv
Energy range bull Beta 025 divide 35 MeVbull Photons lt15 keV
Mechanical characteristicsDosimeters overall dimensions weight bull Gamma Hp(10) DTL-2 holder - 62times26times16 mm
16 gbull DTU holder - 42times28times18 mm 8 gbull Lens Hp(3) face skin Hp(007) Oslash 32times16 mm 9 gbull Finger skin Hp(007) 90times20times2 mm 1 gbull Neutron gamma Hp(10) 48times40times20 mm 30 g
Reference standards Nuclear IEC 61066
DTL-2 DTU-2
MKD (A-type) DVNG-M
DOZA-TLD MULTIPURPOSE TLD SYSTEM
SPC ldquoDozardquoRadiation monitoring equipment
54 55
Continuous and pulsed gamma and X-ray dose H(10) and dose-rate measurementbull Alpha beta and gamma contamination surveybull Neutron dose H(10) and dose-rate measurementbull Gamma radiation flux density in boreholes and
liquid media measurement
Electrical characteristicsPower supply bull UIK-05 four C-size batteriesbull UIK-05-01 rechargeable batterybull UIK-06 rechargeable battery
Interfaces bull RS-232bull USB (via adapter)
bull Detector type automatic determination and corre-sponding measurement modes selection
bull Alarm threshold settings ndash for dose dose-rate alpha and beta contaminations
bull ldquoDetectrdquo and ldquoLocaterdquo modes for survey probes
Reference standards Nuclear IEC 60846 IEC 60325 IEC 61005 IEC 62363
Case
UIK-06 control unit165times78times48 mm 03 kg
DKS-96UNIVERSAL RADIATION SURVEY METER
UIK-05 control unit202times86times90 mm 10 kg
BDZA-96
BDZA-96B
BDZA-96M
BDZA-96S
BDZA-96T
EXTERNAL PROBES ALPHAALPHA BDZA-96Detector bull ZnS(Ag) 70 cm2
Measurement range (for Pu-239)bull 01 divide 104 min-1cm-2
Overall dimensions weightbull Oslash 130times240 mm 11 kg
ALPHA BDZA-96BDetector bull ZnS(Ag) 300 сm2
Measurement range (for Pu-239)bull 01 divide 2103 min-1cm-2
Overall dimensions weightbull Oslash 230times290 mm 40 kg
ALPHA BDZA-96MDetector bull ZnS(Ag) 10 сm2
Measurement range (for Pu-239)bull 01 divide 105 min-1cm-2
Overall dimensions weightbull Oslash 65times240 mm 09 kg
ALPHA BDZA-96SDetector bull ZnS(Ag) 30 сm2
Measurement range (for Pu-239)bull 01 divide 5104 min-1cm-2
Overall dimensions weightbull Oslash 90times240 mm 10 kg
ALPHA BDZA-96TDetector bull Silicon 5 сm2
Measurement range (for Pu-239)bull 01 divide 106 min-1cm-2
Overall dimensions weightbull Oslash 50times60 mm 015 kg
SPC ldquoDozardquoRadiation monitoring equipment
56 57
BETA BDZB-96Detector Scintillator 28 сm2
Measurement range (for Sr-90+Y-90)bull 10 divide 105 min-1cm-2
Energy rangebull 03 divide 30 MeV
Overall dimensions weightbull Oslash 90times230 mm 09 kg
BETA BDZB-99Detector bull GM counter 30 сm2
Measurement range (for Sr-90+Y-90)bull 20 divide 104 min-1см-2
Energy rangebull 012 divide 30 MeV
Overall dimensions weightbull Oslash 88times80 mm 04 kgbull Telescopic pole length 07 m
BETA BDZB-96BDetector bull GM counter 80 сm2
Measurement range (for Sr-90+Y-90)bull 3 divide 104 min-1сm-2
Energy rangebull 012 divide 30 MeV
Overall dimensions weightbull 150times200times110 mm 15 kg
BETA BDZB-96Sbull Detector GM counter 15 сm2
Measurement range (for Sr-90+Y-90)bull 10 divide 3104 min-1cm-2
Energy rangebull 012 divide 30 MeV
Overall dimensions weightbull Oslash 65times65 mm 03 kgbull Telescopic pole length 07 m
BDZB-96
BDZB-99
BDZB-96B
BDZB-96S
EXTERNAL PROBES BETA
GAMMA BDKS-96BDetector bull Tissue-equivalent scintillator Oslash 45times20 mm
Measurement rangebull Dose rate H(10) 01 μSvh divide 1 Svhbull Dose H(10) 01 μSv divide 10 Sv
Energy rangebull 0015 divide 10 MeV
Overall dimensions weightbull Oslash 60times250 mm 085 kg
GAMMA AND BETA BDKS-96SDetector bull Double GM counters
Measurement rangebull Gamma dose rate H(10) 01 μSvh divide 1 mSvhbull Gamma dose H(10) 01 μSv divide 10 Svbull Beta 10 divide 3104 min-1cm-2
Energy rangebull Gamma 005 divide 3 MeVbull Beta 012 divide 3 MeV
Overall dimensions weightbull Oslash 80times80 mm 035 kgbull Telescopic pole length 07 m
GAMMA BDMG-96Detector bull GM counters
Measurement rangebull Dose rate H(10) 01 μSvh divide 10 Svhbull Dose H(10) 01 μSv divide 10 Sv
Energy range bull 005 divide 3 MeV
Overall dimensions weightbull 40times250 mm 05 kgbull Telescopic pole length 07 m 4 m (by request)
EXTERNAL PROBES GAMMA
BDKS-96B
BDMG-96
BDKS-96S
SPC ldquoDozardquoRadiation monitoring equipment
58 59
GAMMA-SEARCH BDVG-96Detector bull Scintillator NaI(Tl) Oslash 63times63 mm
Measurement rangebull Flux density measurement range 4 divide 2000 s-1cm-2
bull Dose rate H(10) for Cs-137 01 divide 30 μSvhbull Sensitivity for Cs-137 3000 (pulsess-1)( μSvh-1)
Overall dimensions weightbull Oslash 88times400 mm 20 kgbull Modular pole length 16 m
GAMMA-SEARCH BDPG-96Detector bull Scintillator NaI(Tl) Oslash 25times40 mm
Measurement rangebull Flux density measurement range 10 divide 8000 s-1cm-2
bull Dose rate H(10) for Cs-137 01 divide 100 μSvhbull Sensitivity for Cs-137 500 (pulsess-1)( μSvh-1)
Overall dimensions weightbull 50times190times480 mm 10 kgbull Telescopic pole length 07 m
GAMMA-SEARCH BDPG-96MDetector bull Scintillator NaI(Tl) Oslash 18times30 mm
Measurement rangebull Flux density measurement range 10 divide 24000 s-1cm-2
bull Dose rate H(10) for Cs-137 01 divide 300 μSvhbull Sensitivity for Cs-137 200 (pulsess-1)( μSvh-1)
Overall dimensions weightbull Oslash 35times320 mm 05 kgbull Telescopic pole length 07 or 38 m
EXTERNAL PROBES GAMMA
BDVG-96
BDPG-96M
BDPG-96
EXTERNAL PROBESGAMMA BDKG-96 STAINLESS STEEL CASING FOR GEOLOGIC APPLICATIONS WELL LOGGINGDetector bull Scintillator NaI(Tl) Oslash 18times30 mm
Measurement rangebull Flux density measurement range 10 divide 105 s-1cm-2
bull Dose rate H(10) for Cs-137 5 divide 2104 μRhbull Sensitivity for Cs-137 200 (pulsess-1)( μSvh-1)
Overall dimensions weightbull Oslash 38times535 mm 36 kgbull Cable length 10 divide 1000 m
NEUTRON BDMN-96Detector bull Scintillator with ZnS(Ag)
Measurement rangebull Dose rate H(10) 01 μSvh divide 01 Svhbull Dose H(10) 01 μSv divide 10 Sv
Energy range bull 0025 eV divide 10 MeV
Overall dimensions weightbull Detector Oslash 54times200 mm 08 kgbull Moderator Oslash 245 mm 73 kg
NEUTRON-SEARCH BDKN-96Detector bull He-3 counter in polyethilene moderator
Measurement rangebull Dose rate H(10) for Pu-Be 01 μSvh divide 01 Svhbull Dose H(10) for Pu-Be 01 μSv divide 10 Sv
Energy range bull 0025 eV divide 14 MeV
Overall dimensions weightbull 295times142times100 mm 225 kg
BDKG-96M
BDMN-96
BDKN-96
SPC ldquoDozardquoRadiation monitoring equipment
60 61
bull No gas supply neededbull Clothing control detachable right hand detector bull Alpha detector optional connection bull Numeric and color (red green) indication of
control resultsbull LED sensor of hand-foot positioning for start of
measurementbull Automatic compensation of gamma background
and contamination of detectorbull Audible alarm signals of the excess of preset
thresholdsbull Measurement value indication min-1cm-2 or
Bqсm2
Reference standards Nuclear IEC 61098
RZB-05D HAND-FOOT-CLOTHING MONITOR
Physical characteristicsDetectors bull Gamma beta - GM countersbull Alpha - scintillatior ZnS(Ag)
Detecting nuclidesbull Alpha Pu-239 U-234 U-238bull Beta Sr-90+Y-90 F-18 Cs-137 Co-60 Tс-99 O-15
N-13 Sr-89 C-11 I-131 Na-22 Ru-106+Rh-106 Tl-204
bull Gamma Tc-99m I-123
Efficiencybull Alpha
Pu-239 40 U-234 25U-238 15
bull Beta Sr-90 +Y-90 40
Measurement range bull Alpha 1 divide 103 min-1cm-2 bull Beta 10 divide 103 min-1cm-2
bull Gamma 5103 divide 5106 min-1cm-2
Energy range bull Alpha 30 divide 80 MeV bull Beta 008 divide 35 MeV bull Gamma 005 divide 30 MeV
Operation temperature range bull Minus 10 divide +50 ordmС
Electrical characteristicsbull Power supply 220 V 50 Hz
Mechanical characteristicsOverall dimensions weight bull 740times750times1180 mm 45 kg
Versionsbull Withwithout alpha detectorbull Indication (min-1cm-2 ) or (Bqсm2)bull Detectors overall dimensions smbull Hand 178 х 235bull Foot 185 х 436
Whole body contamination monitor RZBA-04-04Mbull No gas supply neededbull Compensation for background gamma radiation
and contamination of detector unitsbull Individual threshold setting for each measure-
ment channelbull Visible and audible alarms ldquoCONTAMINATIONrdquo and
ldquoCLEANrdquo bull Indication of contaminated body parts on the
panel with image of the bodybull Optional remote alpha-detector
Physical characteristicsDetectors bull Beta - GM counters scintillatorsbull Alpha - scintillatior ZnS(Ag)
Measurement range bull Beta 5 divide 15000 min-1cm-2
bull Alpha 01 divide 10000 min-1cm-2
Energy range bull Beta 015 divide 25 MeV bull Alpha 40 divide 56 MeV
Operation temperature range bull +5 divide +50 ordmС
Electrical characteristicsPower supply bull 220 V 50 Hz
Interfaces bull RS-232bull RS-485
Mechanical characteristicsOverall dimensions weight bull 2650times940times930 mm 310 kg
Versionsbull Withwithout alpha detectorbull Indication (min-1cm-2 ) or (Bqсm2)
Reference standards Nuclear IEC 61098
RZBA-04-04MWHOLE BODY CONTAMINATION MONITOR
SPC ldquoDozardquoRadiation monitoring equipment
62 63
RZA-05DALPHA HAND-MONITOR
bull No gas supply needed bull Numeric and color (red green) indication of
control resultsbull LED sensor of hand- positioning for start of
measurementbull Audible alarm signals of the excess of preset
thresholdsbull Measurement value indication min-1cm-2 or
Bqсm2
Physical characteristicsDetectors alpha - scintillatior ZnS(Ag)
Efficiencybull Pu-239 20 bull U-234 14bull U-238 8
Measurement range bull 05 divide 105 min-1cm-2
Energy range bull 41 divide 90 MeV
Operation temperature range bull minus 10 divide +50 ordmС
Electrical characteristicsPower supply bull 220 V 50 Hz
Mechanical characteristicsOverall dimensions weight no more bull 740times1400times1450 mm 70 kg
Reference standards Nuclear IEC 61098
bull Simultaneous measurement of alphabeta activi-ties in the sample
bull Active shielding anti-coincidence background subtraction using GM counters
bull Lead shielding 30 mm
UMF-2000 LOW LEVEL ALPHA- BETA- COUNTER
Physical characteristicsDetectors bull Silicon specrometric detector 500 or 1000 mm2
Measurement range bull Alpha 001 divide 1000 Bq bull Beta 01 divide 3000 Bq
Energy range bull Alpha 35 divide 80 MeV bull Beta 005 divide 35 MeV
Electrical characteristicsPower supply bull 220 V 50 Hz
Interfaces bull RS-232bull USB
Mechanical characteristicsOverall dimensions weight bull 337times286times190 mm 22 kg
Versionsbull Detector area 500 mm2
bull Detector area 1000 mm2
UMF-2000 Detector area 1000 mm2
UMF-2000 Detector area 500 mm2
SpectraDec software for alpha-spectrometric measurements
SPC ldquoDozardquoRadiation monitoring equipment
64 65
DRK DOSE AREA PRODUCT METER
DRK-1bull Diagnostic reference level (DRL) of patients
determinationbull Suitable for all basic types of x-ray machines
Physical characteristicsDetector bull Plane-parallel ionization chamber
Measurement range bull 1 divide 104 cGycm2
Electrical characteristicsPower supply bull 220 V 50 Hz
DRK-1M-CTbull Measuring of dose length product
Physical characteristicsDetector bull Pencil Ionization Chamber
Measurement rangebull 05 divide 109 microGym
DRK-1Mbull Measuring of air kerma on sectional area of the
X-ray beam productbull Measuring of air kerma rate on area productbull Measuring of air kerma ratebull Measuring of air kerma
Physical characteristicsDetector bull Plane-parallel ionization chamber
Measurement rangebull 01 divide 109 microGym2
bull 06 divide 6104 microGym2cbull 30 divide 9105 microGycbull 30 divide 9991011 microGyReference standard IEC 60580 2003
bull Measurement of strontium-90 in the foodstuffs agricultural products etc
bull Measurement of gross beta activity in samplebull Self tests using built-in LED
ldquoPROGRESS-BETArdquo SCINTILLATION BETA SPECTROMETER
Physical characteristicsDetector bull Plastic scintillator Oslash70x10 mm
Sample bull Plate Oslash70 mmbull Weight up to 15 g
Energy range bull 02 divide 30 MeV
Minimum detectable activity of Sr-90 in a 10 g sample on a standard planchet Bqsamplebull In case of absence of K-40 in the sample 01 Bqbull In case the activity of K-40 till 5 Bqg 05 Bq
Electrical characteristics Interface bull USB
Mechanical characteristicsWeight bull No more 50 kg
Complete setBasic complete setbull Detector unit with plastic scintillator integrated
power supply amplifier ADC bull Lead shielding bull ldquoProgressrdquo software bull Сheck source for energetic calibration (Sr-90-Y-90) bull Planchet Oslash 70 mm (5 items) bull Sample dencification device bull Procedure manual for measurement of radio-
nuclidesrsquo activity using the scintillation beta spec-trometer ldquoProgressrdquo
Optional equipment and servicebull Personal computer and printer bull Calibrations for radionuclides not included in the
main library of radionuclides
Progress-Beta
Reference standards IEC 61562
SPC ldquoDozardquoRadiation monitoring equipment
66 67
bull Measurement of gamma activity in foodstuffs soil samples and others environmental objects
bull Identification of radionuclides in the sample bull Automatic correction for sample density bull Self-tests using built-in LED
ldquoPROGRESS-GAMMArdquoSCINTILLATION GAMMA SPECTROMETER
Physical characteristicsDetector bull NaI (Tl) Oslash63times63 mm
Validated measurement geometries bull Marinelli beakers (1 liter) Petri dishes (Oslash90 mm)
etc
Energy range bull 02 divide 30 MeV
Minimum detectable activity Bqsamplebull Cs-137 3 Bqbull Th-232 7 Bqbull Ra-226 8 Bq bull К-40 40 Bq
Electrical characteristics Interface bull USB
Mechanical characteristicsWeight bull No more 120 kg
Complete setBasic complete setbull Scintillation detector unit with NaI (Tl) detector
with integrated power supply amplifier and ADC bull Lead shielding 50 mm bull ldquoProgressrdquo software bull Сheck source for energy calibration (Cs-137 +
K-40)bull Marinelli beakers - 1 liter (5 items) bull Petri dishes Oslash 90 mm (5 items) bull Procedure manual for measurement of activity
of radionuclides using the scintillation gamma spectrometer ldquoProgressrdquo
Optional equipment and servicebull Kit for radon measurements including calibration
of ldquoIC-63rdquo geometry for counting the charcoal samples
bull Personal computer and printer bull Calibrations for user defined geometries bull Calibrations for radionuclides not included in the
main library of radionuclides
Progress-Gamma
Reference standards IEC 61563
ldquoPROGRESS-G(P)rdquoPORTABLE SCINTILLATION GAMMA SPECTROMETERbull Field measurements of gamma activity in environ-
mental objects without sampling (4π geometry)bull Laboratory measurement of gamma activity in
foodstuffs soil samples and others environmental objects
bull Identification of radionuclides in the sample bull Automatic correction for sample densitybull Tests using built-in LED
Physical charachteristicsDetector bull NaI (Tl) Oslash45times50 mmbull Lead shielding 20 mm
Validated measurement geometries bull Marinelli beakers (05 liter) Petri dishes (Oslash90 mm)
etc
Energy range bull 02 divide 30 MeV
Minimum detectable activity in 05-litre Marinelli beaker bull Cs-13710 Bqkgbull К-40100 Bqkgbull Ra-22618 Bqkg bull Th-23216 Bqkg
Minimum detectable activity in 30 min (4π geometry) bull Cs-137 2 Bqkgbull К-40 30 Bqkgbull Ra-226 4 Bqkg bull Th-232 3 Bqkg
Electrical characteristicsPower supply bull Rechargeable batterybull 220 V 50 Hz
Interface bull USB RS-232
Weight bull No more than 60 kg
Complete setBasic complete setbull Scinttillation detector unit with NaI(Tl) bull ldquoProgressrdquo softwarebull Сontrol unit ldquoSputnikrdquo for aquisition and analisys
of spectra with built-in memory for spectral databull Casebull Lead shielding (2 cm) for laboratory usebull 05-litre Marinelli beakers ndash 5 itemsbull Na-22 check sourcebull Power adapter BPS-01bull Operation manualbull Procedure manual for measurement of activity
of radionuclides using the scintillation gamma spectrometer ldquoProgressrdquo
Optional equipment and servicebull Kit for radon measurements with charcoalbull Built-in dose rate meterbull Additional memory (RAM) for storage of 64
spectrabull Additional power adapterbull Notebook and printer
Progress-Gamma
Reference standards IEC 61563
SPC ldquoDozardquoRadiation monitoring equipment
68 69
Physical characteristicsDetectorbull Scintillation detector ZnS (Oslash 60 mm)
Samplebull Thin sample - diameter up to 70 mm bull Preparation technique - electro-depositionbull Thick sample - diameter 70 mm weight
200300 mg bull Preparation technique - application of powders
(prepared by radiochemical concentration by water evaporation or by pounding of mineral samples) onto a planchet with the help of spirit
Energy rangebull 15 divide 8 MeV
Minimum detectable activitybull Thin samples no more than 910-3 Bqsamplebull Thick samples no more than 180 Bqkg
Mechanical characteristicsOverall dimensions weightbull 195times120times210 mm 34 kg
Complete setBasic complete setbull Alpha radiometer ldquoProgress-ARrdquobull Check source (uranium isotopes)
Set of accessoriesbull Procedure manual for measurements of radi-
oactivity using scintillation alpha radiometer ldquoProgress-ARrdquo
bull ldquoProgressrdquo software
ldquoProgress-ARrdquo
bull Measurement of gross activity of alpha emitting radionuclides in thin samples
bull Measurement of gross activity of alpha emitting radionuclides in thick samples
bull Measurement of activity deposited on aerosol filters
ldquoPROGRESS-ARrdquoALPHA RADIOMETER
Several fixed positions of the detector enable to perform measurements in various geometries and to estimate the content ofbull Cs-137 in the whole bodybull I-131 in thyroidbull Co-60 Cs-137 Mn-54 Cr-51 in lungsbull Database for storage of measurement data and
resultsbull Uncertainty calculations based on measurement
databull Self tests using built-in LED
ldquoPROGRESSrdquo WHOLE BODY COUNTER
Physical characteristicsDetectorbull scintillation detector NaI (Tl) Oslash63times63 mm
Energy rangebull 02 divide 28 MeV
Minimum detectable activitybull By Cs-137 in the whole body - 1200 Bqbull By I-131 in thyroid - 100 Bqbull By Co-60 Cs-137 Mn-54 Cr-51 in lungs - 200 Bq
Mechanical characteristicsWeight bull No more than 120 kg
Complete setBasic complete setbull Collimator with rotator and holderbull Detector with incorporated ADCbull Patient chair and table for collimatorbull Check source Na-22bull Procedure manual for lifetime measurement of
gamma-emitting radionuclidesrsquo activity in human body using the gamma-spectrometer of human radiation ldquoProgressrdquo
bull laquoProgressraquo software
Optional equipment and servicebull Program of internal radiation committed internal
radiation effective dose calculation by the stand-ard model
bull Background phantombull Personal computer and printer
Collimator with rotator and holder
SPC ldquoDozardquoRadiation monitoring equipment
70 71
bull Categorization of wastes for the purpose of fur-ther processing including wastes with unknown radionuclide composition
bull Measurements during the incoming waste inspec-tion (accepting for storage disposal)
bull Certification of unconditioned and conditioned wastes in closed containers without opening them (at nuclear plants or at facilities providing collection storage transportation conditioning processing temporal storage and final disposal of radioactive waste)
bull Activity measurement of extended objects in situ without opening the equipment
bull Activity measurement of extended objects after opening (for example assessment of tubes used for oil transportation)
MKG-01D ldquoSADOVNIKrdquoSPECTROMETRY SYSTEM
Physical charachteristicsDetectorbull Detector unit GEM (GMX) with HPGe detector and
multi-positioning cryostat CFG-PMOD4-7 with 7 litre Dewar
bull Dose rate probe BDMG-200
Energy range bull With GEM detector 004 divide 30 MeVbull With GMX detector 0005 divide 15 MeVbull Dose rate probe BDMG-200 ndash 005 divide 30 MeV
Measurement rangebull 110-7 divide 10 Svhbull Relative efficiency of detection (in photopeak) at
13325 MeV (Co-60) 10 divide 150
Electrical characteristicsPower supplybull 220 V 50 Hz
Interfacebull USB
Complete setBasic complete setbull Spectrometric detector unit GEM (GMX) with
HPGe detector and multi-positioning cryostat with 7 litre Dewar
bull Portable digital multichannel analyzer DigiDARTbull Dose rate probe BDMG-200bull Autonomous power supply unit with built-in
batterybull Industrial computer keyboardbull Laser range-finderbull Thermographic printerbull Web-camerabull Device equipped with stepper motor for position-
ing of the spectrometric detectorbull Calibration device with reference sources
(Am-241 Co-60 Ba-133 Eu-152) for energy calibration
bull Removable collimators with end capbull Measurement proceduresbull ldquoClasterrdquo software
bull Measurement of gross alpha activity of alpha-emitting radionuclides
bull Measurement of alpha-emitting radionuclides activity in thin-layer samples meeting alpha-spectrometry requirements
Physical characteristicsDetectorbull Silicon ion-implanted 450 mm2
bull Easy to decontaminate thin windowbull dead layer less than 015 μmbull Background count rate in the range 3 divide 9 MeVbull No more than 09 h-1cm-2 for 450 mm2 detector
Energy rangebull 2 divide 9 MeVbull Lower limit of measurement range (minimum
detectable activity) 01 Bqbull Background count rate no more than 100 counts
in 24 hours
Electrical characteristics Power supplybull 220 V 50 Hz
Interfacebull USB
Complete setBasic complete setbull Detector unit with vacuum measuring chamber
and vacuum control systembull Low noise vacuum pump (type 2FY-05B or
equivalent)bull Check sourcebull ldquoProgressrdquo softwarebull Vacuum tube
MKS-01A ldquoMULTIRAD-ASrdquoALPHA SPECTROMETER
SPC ldquoDozardquoRadiation monitoring equipment
72 73
UCRV-2AIRFLOW MONITOR
bull Monitor of the air flow through filter of centralized multichannel sampling system
bull Radiation monitoring system (RMS) integration for internal exposures determination
bull Volume and flow rate measurements of the air that have passed through a analytical filter
bull Bar-code for filter identificationbull Operation as either standalone unit or as a part of
the RMS
Physical characteristicsMeasurement range of air volume bull 001 divide 9999 m3
Operation temperature range bull minus 20 divide +50 ordmС
Electrical characteristicsPower supply bull 220 V 50 Hz
Interface bull RS-485
PVP-06PORTABLE AIR SAMPLER
Air Sampler PVP-06 is indispensable for monitoring the radiation situation where the concentration of radioactive aerosols in the air does not require a sta-tionary sampling equipment Sampling head PVP-06 provides easy change of filters and cartridges
Purposebull To monitor the concentration of radioactive aero-
sols in the air sites
Controlled aerosolsbull Alpha- and beta-active aerosolsbull Daughter products of decay of radon and thoronbull Iodine isotopes
Physical characteristicsTypes of filtersbull Aerosol AFA-RSP-20bull Iodine AFA SI-20
Flow rate bull 33∙10-4 ndash 233∙10-4 m3s (20 divide 140 l min)
Electrical characteristicsPower supply bull 220 V50 Hzbull The vehicle power supply 108 divide 145 Vbull Internal battery
Minimal working time on internal battery to recharge bull 8 hours
Power consumption (at a flow rate of 100 lmin) bull 40 VA
Environment characteristicsOperating temperature bull minus 10 divide +40 deg C
Maximum humidity bull 90
Pressure bull 860 to 1060 hPA
Noise generated by the pump bull lt 55 dBA at 1 m
Mechanical characteristicsDimensions weight bull 241 times 108 times 160 mm 28 kg
Case material bull Plastic
Complete setbull Air sampler PVP-06bull AC power adapterbull Filters AFA-RSP-20 - 100 pcsbull Packaging for filters - 40 pcsbull Casebull Operation manualbull Calibration certificate
Optional equimpient bull Kit for sampling sorption columns of activated
carbon Ř head of sorption columns with protective
covers Ř activated charcoal SKT-3 - 1 pkg (02 L) Ř charocoal samples SC-13 - 8 pcs
bull Car charger bull Tipod bull Shoulder strapbull Calibration stand bull Filters AFA SI-20 - 100 pcs
Consumablesbull Aerosol filters AFA RSP-20bull Iodine filters AFA SI-20
SPC ldquoDozardquoRadiation monitoring equipment
74 75
Calibration of gamma dose and dose rate meters
Calibration ofbull Ambient equivalent dose H(10) meters (Sv Svh)bull Personal equivalent dose Hp(10) meters (Sv Svh)bull Exposure dose X meters (R Rh)bull Two sources in irradiator bull Select source and collimator opening using
tumbler
UPG-P DESKTOP GAMMA BEAM IRRADIATOR
Physical characteristicsRange of reproduced dose rate bull 05 μSvh divide 10 mSvh (50 μRh divide 100 mRh)
Sources activities bull 6times106 6times108 Bq (02 20 mCi) Cs-137
Overall dimensions bull 1250times400times300 mm
Irradiator weight bull Not more than 37 kg
Calibration bench weight bull Not more than 15 kg
Reference standards IEC 60846 IEC 61526
Physical characteristicsDetectorbull Silicon
Measurement range EEC measurement bull Measurement range of radon EEC
10 divide 10bull106 Bqbullm-3
bull Measurement range of thoron EEC 05 divide 10bull104 Bqbullm-3
bull Air flow through the filter 100plusmn05 lmin
Concentration measurementbull Measurement range of radon-222 concentration
in air 10 divide 20bull106 cpsbull Measurement range of 216Po(ThA)
1bull10-3 divide 1bull102 cpsbull Air sampler flow rate
10plusmn02 lminbull Measurement range of radon-222 concentration
in water samples 6 divide 800 Bqbullkg-1
bull Measurement range of radon-222 flux from soil surface 20 divide 103 mBqsbullm2
bull Measurement range of radon-222 concentration with preliminary sampling of air using air sam-plers 20 divide 107 Bqbullm-3
bull Measurement range of radon-222 concentration in samples of soil air 103 divide 106 Bqbullm-3
Operation temperature range bull 1 divide 35 ordmC
Electrical characteristicsPower supply bull 80 VA
Mechanical characteristicsOverall dimensions weight bull 220times200times165 mm 36 kg
ldquoALPHARAD PLUSrdquoRADON THORON amp THEIR PROGENY MONITORbull Measurement of radon and thoron concentration
and effective equivalent concentration (EEC)bull In the airbull In the indoor air of residential public and industri-
al buildings and structuresbull Measurement of radon in drinking water sourcesbull Measurements of radon flux from the soil surface
at land plots allocated for construction of houses public buildings and industrial facilities
bull Measurements of radon concentration in soil air
Reference standards IEC 61577
SPC ldquoDozardquoRadiation monitoring equipment
76 77
UKPN-2M-D NEUTRON BEAM IRRADIATOR
Reference standards IEC 61005 61322
Calibration of neutron dose and dose rate meters
Calibration ofbull Ambient equivalent dose H(10) meters (Sv Svh)bull Personal equivalent dose Hp(10) meters (Sv Svh)bull Flux density of neutrons (cm-2∙s-1)bull Transfer container for temporary storage of
sources bull Red light signal of source working position
Physical carachteristicsRange of reproduced dose ratebull 20 divide 800 μSvh
Range of reproduced flux densitiesbull 10 divide 400 cm-2∙s-1
Type of a source in use bull Pu-Be
Activity of a source in usebull 24х1011 Bq (with density of 107 s-1)
Overall dimensions weight no morebull 3000x750x2000 mm 300 kg
Required room dimensionsbull not less than 7x3x3 m
Electrical characteristicsPower supply bull 220 V 50 Hz
Calibration of gamma dose and dose rate meters
Calibration ofbull Ambient equivalent dose H(10) meters (Sv Svh)bull Personal equivalent dose Hp(10) meters (Sv Svh)bull Exposure dose X meters (R Rh)bull Four sources in irradiator bull Select source and move to working position
return to storage position using special rodbull Transfer container for temporary storage of
sources bull Red light signal of source working position
UPGD-2M-DGAMMA BEAM IRRADIATOR
Physical characteristicsRange of reproduced dose rate bull 05 μSvh divide 50 mSvh (50 μRh divide 5 Rh)
Maximum activity of source bull 2times1011 Bq (50 Ci) Cs-137
Overall dimensionsbull Irradiator 800times500times500 mmbull Guide rails length 30 mbull Height 16 mbull Weight not more than 700 kgbull Required room dimensions not less than 7x3x3 m
Electrical characteristicsPower supply bull 220 V 50 Hz
UPGD-2M-D
Reference standards IEC 60846 IEC 61526 IEC 61066
SPC ldquoDozardquo
78 79
Contents
MEASURING UNITS
DBG-S11D wide range gamma area monitor 40
UDKS-100 gamma and X-ray area monitor 41
UDMN-100 neutron area monitor 41
ALARM UNITS
BAS-2 ldquoMICROrdquo external visual alarm 42
BZS-2 ldquoMicrordquo external audible alarm 42
Illuminated warning signs 43
ldquoImpulsrdquo external display unit 43
UIM-3D area monitor count rate meter 44
DKG-05D personal gamma dosimeter 46
DVS-02D gamma-neutron personal electronic dosimeter 47
DVGI-8D new pen-type personal ionization chamber dosimeters 48
DKG-02U ldquoARBITERrdquo wide range gamma-dosimeter 49
DKG-07D ldquoDROZDrdquo gamma-dosimeter 50
MKS-15D ldquoSNEGIRrdquo multi ndash purpose radiation survey meter 51
SRPS-05D gamma monitor 52
DOZA-TLD multipurpose TLD system 53
DKS-96 universal radiation survey meter 54
EXTERNAL PROBES ALPHA
Alpha BDZA-96 55
Alpha BDZA-96B 55
Alpha BDZA-96M 55
Alpha BDZA-96S 55
Alpha BDZA-96T 55
EXTERNAL PROBES BETA
Beta BDZB-96 56
Beta BDZB-99 56
Beta BDZB-96B 56
Beta BDZB-96S 56
EXTERNAL PROBES GAMMA
Gamma BDKS-96B 57
Gamma and beta BDKS-96S 57
Gamma BDMG-96 57
EXTERNAL PROBES GAMMA
Gamma-search BDVG-96 58
Gamma-search BDPG-96 58
ContentsRadiation monitoring systemldquoPELIKANrdquo Radiation monitoring system (RMS) 6
BDMG-101 high range gamma area monitor 10
DBG-S11D wide range gamma area monitor 11
BDRG-52 high range gamma area monitor for accident and post-accident conditions 12
UDGP-01 Liquid technological environments monitor 13
UDMN-100 neutron area monitor 14
UDKG-100 Wel Liquid gamma monitor 14
BOP-1M data processing and transmission unit 15
UDA-1AB particulate monitor 16
UDG-1B noble gas monitor 17
UDG-03D noble gas monitor 18
UDI-1B iodine monitor 19
UDGB-01 noble gasesH-3C-14 monitor 20
UDGP-01 steam generator leakage monitor 21
UPPVM air flow parameters monitor 22
ldquoIMPULSrdquo external display unit 23
BI-2 remote display amp alarm unit 24
BASBAS-1s external alarm 25
SKGAV stack monitor 26
RMS software 28
RMS workstation ndash operator console 29
Configurator software 29
RM RACK radiation monitoring rack 30
SRKS-01D criticality accident alarm system 32
ldquoATLANT-Mrdquo environmental radiation monitoring system 34
ldquoBREEZErdquo high-volume air sampler 35
ldquoGAMMA-SENSORrdquo gamma-survey system 36
Radiation monitoring equipmentAREA MONITOR ldquoFREGATrdquo 38
BPI-1D local display unit 39
80
Gamma-search BDPG-96M 58
Gamma BDKG-96 stainless steel casing for geologic applications well logging 59
EXTERNAL PROBES NEUTRON
Neutron BDMN-96 59
Neutron-search BDKN-96 59
RZB-05D Hand-foot-clothing monitor 60
RZBA-04-04M whole body contamination monitor 61
RZA-05D alpha hand-monitor 62
UMF-2000 low level alpha- beta- counter 63
DRK dose area product meter 64
ldquoPROGRESS-BETArdquo scintillation beta spectrometer 65
ldquoPROGRESS-GAMMArdquo scintillation gamma spectrometer 66
ldquoPROGRESS-G(P)rdquo portable scintillation gamma spectrometer 67
ldquoPROGRESS-ARrdquo alpha radiometer 68
ldquoPROGRESSrdquo whole body counter 69
MKG-01D ldquoSADOVNIKrdquo spectrometry system 70
MKS-01A ldquoMULTIRAD-ASrdquo alpha spectrometer 71
UCRV-2 airflow monitor 72
PVP-06 portable air sampler 73
ldquoALPHARAD PLUSrdquo radon thoron amp their progeny monitor 74
UPG-P desktop gamma beam irradiator 75
UPGD-2M-D gamma beam irradiator 76
UKPN-2M-D neutron beam irradiator 77
Radiation monitoring system SPC ldquoDozardquo
24 25
BASBAS-1S EXTERNAL ALARM
Generation of audible and visual signals of the excess of preset thresholds RMS monitorsbull Audible alarm 80 divide 100 dBA at distance 1 mbull Visual alarm green yellow red
Distance from RMS monitorbull BAS up to 20 mbull BAS-1s up to 1200 m
Power supply bull 220 V 50 Hz
Overall dimensions weight bull BAS 145times108times460 mm 18 kg bull BAS-1s 166times109times466 mm 18 kg
Reference standards EMC IEC 61010 IEC 61000-6-2 Seismic IEC 60980
Physical characteristicsLength of communication cablebull up to 1200 m
Displayed page size bull 4 lines of 20 characters
Volume of loaded information bull 10 pages
Change of pagesbull programmed or by pressing a button
Operating temperature rangebull minus 40 divide +50 ordmC
Electrical characteristicsbull Power supply 9 divide 18 VDCbull Interfaces RS-485
Mechanical characteristicsbull Protection index IP 65bull Overall dimensions weight 222times164times73 mm
40 kg
BI-2 REMOTE DISPLAY amp ALARM UNIT
bull Display of data received from monitors of RMSbull Audible and visual alarms on exceeding preset
thresholds of the RMS equipment bull Individual threshold setting for each measure-
ment channelbull Audible alarm 80 divide 100 dB at a distance of 1 m bull Visual alarm red yellow green
Reference standards EMC IEC 61010 IEC 61000-6-2 Seismic IEC 60980
Radiation monitoring system SPC ldquoDozardquo
2726
Electrical characteristicsbull Power supply 220 V 50 Hz bull Interfaces RS-232 RS-485 Ethernetbull programmable relay output (SPDT relay)
Alarmbull Sound alarm 80 divide 100 dBA at distance 1 mbull Visual alarm green yellow redbull Connection of the external alarm unit ldquoBASrdquo type
Related monitors and equipmentsbull UDA-1AB particulate monitorbull UDG-1B noble gas monitorbull UDI-1B iodine monitorbull UPPVM air flow parameters monitorbull Sampling and sample separation rack
Air flow parameters monitor rack
Reference standards Nuclear IEC 60761 IEC 61171 IEC 61172 IEC 62302 ISO 2889 EMC IEC 61010 IEC 61000-6-2 Seismic IEC 60980
Sampling and sample separation rack
Continuous monitoring of radioactivity in gaseous effluentsbull Automatic monitoring of the alpha- and beta-
radioactive aerosol noble gas and radioiodine concentrations in the air in ventilation ducts and stacks
bull Monitoring of the flow rate temperature and humidity of the gas flow
bull Separation of gaseous effluent into targeted fractions by means of a two-stage filter
bull Reversion of gas after analysis to the ventilation system
Physical characteristics
Particulate (UDA-1AB)bull Silicon specrometric detectors (2 pcs for measure-
ment and for gamma-background compensation) bull Filter tape types LFAS FSLWbull Tape consumption (when continuous operation)
10 m50 days
Measurement range bull Alpha 10-2 divide 2105 Bqm3 bull Beta 10-1 divide 106 Bqm3
Energy range bull Alpha 30 divide 90 MeV bull Beta 005 divide 30 MeV
Noble gas (UDG-1B)bull silicon detectors (2 pcs for measurement and for
gamma-background compensation)
Measurement range bull 104 divide 6109 Bqm3
Energy range bull 008 divide 30 MeV
Iodine (UDI-1B)bull scintillation detectors CsI(Tl) (2 pcs for measure-
ment and for background compensation)
SKGAV STACK MONITOR
Particulate noble gas and iodine monitors rack
Measurement range bull 37 divide 37105 Bqm3
Energy range bull 015 divide 30 MeV
Air flow parameters (UPPVM)Measurement range bull air flow velocity 1 divide 20 msbull air temperature 0 divide +80 ordmСbull air humidity 10 divide 95
Radiation monitoring system SPC ldquoDozardquo
28 29
CONFIGURATOR SOFTWAREMaintenance and set-up softwarebull Set-up and verify RMS monitorsbull Control testing adjustment and repair of RMS
monitorsbull Monitors measurement results archive receive
and View bull Communication through RS-232
RMS WORKSTATION ndash OPERATOR CONSOLEOrganization of interaction of the RMS Server and Monitors
Single monitor console includes vandal-proof key-board amp UPS
Reference standard IEC 61559-1 IEC 61559-2
RMS SOFTWAREData acquisition storing and visual representation RMS monitors measurement resultsbull Ethernet IEEE 8023 networkbull Clientserver architecturebull TCPIP protocolbull Oracle based Data Basebull Supremal by means InSat MasterSCADA
Radiation monitoring system SPC ldquoDozardquo
30 31
Delivery setComposition and modification depend on the tasks to be solved using the RM Rack
The rack which is an integral part of RM Rack accommodatesbull Monitors UDA-1AB UDG-1B UDG-03D UDI-1B
UDGB-01Tbull DBG-S11D Wide range gamma area monitor
BDMG-101 High range gamma area monitor UDMN-100 Neutron area monitor BDRG-52R High range gamma area monitor
bull BI-2 Remote display amp alarm unitbull Pump unit BN-01bull Data processing and transmission unit BOP-1Mbull External alarm BAS or BAS-1sbull Equipment of sampling line (flow meters ball
valves filter holder piping solenoid valve)bull Switchboard (intended for switching of all equip-
ment and transfer of data to the upper level via the unified communication channel)
RM RACK RADIATION MONITORING RACK
The radiation monitoring rack (RM Rack) is designed for continuous monitoring of radiation parameters in premises and technological systems at nuclear facil-ities RM Rack can be used as a structural element of the lower-level of RMS at nuclear power plants and other nuclear facilities that involved in obtaining processing use and storage of radioactive materials
FeaturesContinuous automatic monitoring of the alpha- and beta- radioactive aerosol beta-emitting radioactive gases and radioiodine concentrations in the working air and in the air in stacks and others radiation parameters in the facilities
The stand providesbull Primary processing storage and transmission of
measured and related data into the information channel based on the Ethernet IEEE 8023 inter-face (TCPIP protocol)
bull Transfer of required data to the location where the equipment is installed via technological channels based on RS-232 interface
bull Generation of audible and visual warning alarm signals when the preset thresholds are exceeded
bull Display of received data on the LCD
Radiation monitoring system SPC ldquoDozardquo
32 33Reference standards IEC 60860 ANSIANS-83 ISO 7753
Purposebull Detection and recording of criticality accident
(CA) by measuring the absorbed dose rate of gamma-neutron radiation in the premises of monitored object its comparison with a threshold value and generation of audible and visual signals
bull Automatic collection processing storage and display of measurement data and related infor-mation as visual and graphical representation for operators of nuclear safety service
Functions of the systembull Detection and recording of CA events by con-
tinuous measurement of absorbed dose rate of gamma radiation comparison of measured values with preset thresholds generation of signals to activate the alarm
bull Activation of audible visual alarmbull In the event of CA turning on warning signals
ldquoDO NOT ENTERrdquo at illuminated information pan-els placed at the entrances to the controlled area
Featuresbull Data can be transferred to external data commu-
nication channel using RS-485 interface (DiBus data exchange protocol)
bull Automatic self-testing of detection units BR-04D with display of information about the type of fault
bull Possibility for connecting additional a detection and alarm units
bull Ability to function in general regardless of the functioning of components within the agreed scope of nuclear safety tasks
bull Radiation hardness up to 100 Gy
SRKS-01DCRITICALITY ACCIDENT ALARM SYSTEM
Features of softwarebull Collection of information via RS-485 network
displaying it on the PC monitor transmission to remote users archiving and storage
bull Status monitoring and display of values measured by BR-04D and DBG-S11D in locations as per layout of premises
bull Access to archived data with possibility to gener-ate reports for periods determined by operator
bull Maintenance and archiving of a log of dosimetric measurements data and events along with their time stamps
bull Possibility to transfer data to external users via Ethernet network for integrating of CA into higher level systems
Basic complete setLower level bull Control unit with power supplybull BR-04D detection unitsbull BZS-01D audible alarm unitsbull BSS-01D visual alarm unitsbull SIT-01D illuminated warning signsbull PBZ panels for muting audible alarmbull Network communication module
Additional lower layer devicesbull DBG-S11D wide range gamma area monitor
Upper layer bull CDP central display panelbull Service workstation
RS-485
RS-485
RS-4
85
Audible alarm units BZS-01D
Illuminated warning signs SIT-01D
Detection units BR-04D
Network communication
moduleDBG-S11D wide range gamma area monitor
Panels for muting audible alarm
Control unit with power supply
Visual alarm units BSS-01D
RS-485
RS-485
RS-4
85
Audible alarm units BZS-01D
Illuminated warning signs SIT-01D
Detection units BR-04D
Network communication
moduleDBG-S11D wide range gamma area monitor
Panels for muting audible alarm
Control unit with pow-er supply
Visual alarm units BSS-01D
RS-485
RS-4
85
Audible alarm units BZS-01D
Illuminated warning signs SIT-01D
Detection units BR-04D
Network communication
moduleDBG-S11D wide range gamma area monitor
Panels for muting audible alarm
Control unit with power supply
Visual alarm units BSS-01D
RS-485
RS-485
RS-4
85
Audible alarm units BZS-01D
Illuminated warning signs SIT-01D
Detection units BR-04D
Network communication
moduleDBG-S11D wide range gamma area monitor
Panels for muting audible alarm
Control unit with power supply
Visual alarm units BSS-01D
Ethernet
Central display panel Service workstation
RS-485
RS-485
RS-4
85
BZS-01D audible alarm units
SIT-01D illuminated warning signs
BR-04D detection units
Network communication
moduleDBG-S11D wide range gamma area monitor
PBZ panels for muting audible alarm
Control unit with power supply
BSS-01D visual alarm units
Radiation monitoring system SPC ldquoDozardquo
34 35
ldquoBREEZErdquoHIGH-VOLUME AIR SAMPLER
Physical characteristicsbull Measurement range of air flow rate
250 divide 1200 m3hbull Continuous operation time not less than 24 h
Filter materialsbull High-purity glass fiberbull Pure quartz or cellulosebull Filter fabric FPP-15-15
Electrical characteristicsPower supply bull 220380 V 50 Hz
Interfaces bull RS-485bull Ethernetbull GSMGPRS (option)
Environmental characteristicsTemperature range bull minus 40 divide + 40 ordmC
Relative humidity limit at 35 ordmC bull 95
Atmospheric pressure range bull 840 divide 1067 kPa
Versionsbull Standalone unit bull Part of Environmental Radiation Monitoring
System (ERMS)
Type of detection unitsbull Beta block BDZB-100Lbull DBG-S11D wide range gamma area monitorbull Scintillation spectrometric block
The motor of Air Sampler is controlled by an electronic flow sensor that detects changes in the operators pre-set flow rate caused by changes in temperature barometric pressure and pressure drop due to dust loading on filter media It compensates for these changes by adjusting the motor speed to maintain the pre-set flow ratebull Measurement of parameters of ionizing radiation bull Standalone mode of operation or as the part
of Environmental Radiation Monitoring System (ERMS)
Purposebull Environmental Radiation Monitoring System
(ERMS) in the control and buffer areas of the radia-tion and nuclear facilities
Referencesbull Since the year 2000 the system is successfully
operating the ERMSs at 8 Russian nuclear power plants (about 180 monitoring stations)
bull Since the year 2005 the ERMS is operating in the Moscow (about 40 monitoring stations)
bull Since the year 2005 the regional ERMS is under operation in several Russian Federation regions
Basic complete setMonitoring stations bull Data processing and transmission unit BOP-1TA bull Gamma area monitor DBG-S11D
Central data processing station (CDPS)bull Data processing and transmission unit BOP-1TAbull Server
By requestbull Emergency Response and Crisis Management
Centers for enterprisesbull Regional Emergency Response and Crisis Manage-
ment Centersbull rdquoBreezerdquo High-Volume Air Samplerbull Mobile lab with gamma-survey system rdquoGammandash
sensorrdquo
ldquoATLANT-MrdquoENVIRONMENTAL RADIATION MONITORING SYSTEM
Monitoring system for the continuous radiation monitoring of territories and facilities with the data transmission GSMGPRS network
Data transmission bull GSMGPRS
Power supply bull 220 V 50 Hz
Continuous autonomous operation (at 20 ordmC)bull From built-in battery not less than 5 hoursbull From external battery not less than 24 hours
Operation temperature bull Minus 40 divide +50 ordmC
Operation humidity bull Up to 98
Protection bull IP65
Reference standards Nuclear IEC 61017-11991 IEC 61017-21994
36
Radiation Monitoring Equipment
bull Localization of radioactive contaminationsbull Database with dose rate contaminations
spectra measurement date amp time coordi-nates
bull Work as part of mobile laboratory or as part of Environmental Radiation Monitoring System with real-time data transfer
Physical characteristicsDetector bull Scintillation NaI (Tl) GM counters
Measurement rangebull 01 ndash 107 μSvh
Energy range bull 005 ndash 3 MeV
Operation temperature range bull minus 10 divide +50 ordmС
Electrical characteristics bull Power supply 220 V 50 Hz
ldquoGAMMAndashSENSORrdquoGAMMA-SURVEY SYSTEM
SPC ldquoDozardquoRadiation monitoring equipment
38 39
AREA MONITOR ldquoFREGATrdquoArea Monitor ldquoFregatrdquo is designed for building rela-tively simple and inexpensive radiation monitoring systems at such facilities as radionuclide sources storage areas isotope products warehouses nuclear medicine departments PET centers calibration laboratories where sources of ionizing radiation are used etc
Small scale automated radiation monitoring systems built with ldquoFregatrdquo components featuring audible and visual alarms are matched suitable to meet the regulatory radiation safety requirements
Area monitor ldquoFregatrdquo requires virtually no adjust-ment it is simple and convenient for installation and operation
BPI-1D LOCAL DISPLAY UNIT
Display of monitored parameters values received from external measuring devices
Purposebull Processing and display of values of monitored
parameters on information panel bull Comparison of values of monitored parameters
with thresholdsbull Transfer of monitored parametersrsquo values to
networkbull Generation of alarm in case of exceeding of preset
thresholds including external alarm devices
FeaturesTesting the unit and connected devicesbull Visually on the panelbull Using adjustment software when connected to
PC via USB
Automatic self-testing
The panel displays the following informationbull Diagnostic information about the status of con-
nected devicesbull Current date and timebull Values of measured parametersbull Position of measured values with respect to the
thresholds in the form of scales with green yellow and red zones
bull Time history (trend) for each measured value
Physical characteristicsTemperature range bull minus 10 divide + 50 ordmC
Maximum number of connected devicesbull measuring devices 15bull external audible and visual alarm 15
Display diagonal bull 152 cm (6)
Electrical characteristicsbull Interfaces RS-485bull Power supply 220 V 50 Hz 12 divide 24 V
Mechanical characteristicsbull Protection index IP54bull Paint decontaminable
Overall dimensions weightbull 296x248x118 mm 5 kg
DBG-S11D wide range gamma area monitor
UDMN-100 neutron area monitor
Ethernet RS-485
UDKS-100 gamma and X-ray area monitor
BPI-1D Local display unit
BAS-2 ldquoMicrordquo external visual alarm
BZS-2 ldquoMicrordquo external audible alarm
ldquoImpulsrdquo external display unit
Service workstation
Illuminated warning signs
SPC ldquoDozardquoRadiation monitoring equipment
4140
Continuous automatic monitoring of the gamma- X-ray ambient dose equivalent rate
Physical characteristicsbull Detector tissue-equivalent plastic scintillator
Oslash 45times20 mm
Measurement range bull Dose rate measurement range 01 μSvh divide 1 Svh bull Energy range 0015 divide 10 MeV
Mechanical characteristicsbull Protection index IP65bull Paint decontaminable
Overall dimensions weightbull Oslash72times265 mm 15 kg
UDKS-100 GAMMA AND X-RAY AREA MONITOR
UDMN-100 NEUTRON AREA MONITOR
Physical characteristicsbull detector ndash scintillator ZnS(Ag) Li-6
Measurement range bull 01 μSvh divide 01 Svh
Energy range bull 0025 eV divide 100 MeV
Temperature range bull minus 45 divide +50 ordmC
Electrical characteristicsbull Interfaces RS-485
Mechanical characteristicsbull Protection index IP 65bull Paint decontaminable
Overall dimensions weight bull 428times258times347 mm 115 kg
Continuous automatic monitoring of the neutron-radiations ambient dose equivalent ratebull Spherical polyethylene moderator Oslash 239 mm
MEASURING UNITS
DBG-S11D WIDE RANGE GAMMA AREA MONITOR
Continuous automatic monitoring of the gamma- ambient dose equivalent rate
Physical characteristicsbull Detector ndash GM counters
Measurement rangebull DBG-S11D 01 μSvh divide 10 mSvhbull DBG-S11D-01 01 μSvh divide 10 Svhbull DBG-S11D-02 01 μSvh divide 100 Svh
Energy rangebull 005 divide 30 MeV
Temperature range bull minus 40 divide +50 ordmC
Electrical characteristicsbull Interfaces RS-485 USB
Mechanical characteristicsbull Protection index IP 68bull Paint decontaminable
Overall dimensions weightbull DBG-S11D Oslash 68times141 mm 065 kg bull DBG-S11D-01 Oslash 68times179 mm 07 kgbull DBG-S11D-02 Oslash 68times179 mm 07 kg
Versionsbull DBG-S11Dbull DBG-S11D-01bull DBG-S11D-02
Reference standards Nuclear IEC 60846 IEC 60532 EMC IEC 61010 IEC 61000-6-2 Seismic IEC 60980
SPC ldquoDozardquoRadiation monitoring equipment
4342
ALARM UNITS
Generation visual signals of the excess of preset thresholds
Physical characteristicsLength of communication cablebull up to 1200 mbull Alarm Visual alarm green yellow red
Electrical characteristicsbull Power supply +12 V
Mechanical characteristicsbull Protection index IP 23
Overall dimensions weight 160times84times41 mm 02 kg
BAS-2 ldquoMICROrdquo EXTERNAL VISUAL ALARM
Generation audible signals of the excess of preset thresholds
Physical characteristicsLength of communication cablebull up to 1200 mbull Audible alarm 80 divide 100 dB at a distance of 1 m
Electrical characteristicsbull Power supply +12 V
Mechanical characteristicsbull Protection index IP 23
Overall dimensions weight 160times84times41 mm 02 kg
BZS-2 ldquoMICROrdquo EXTERNAL AUDIBLE ALARM
Physical characteristicsLength of communication cablebull up to 1200 m
Electrical characteristicsbull Power supply 220 V 50 Hz
Mechanical characteristicsbull Protection index IP 23
Overall dimensions weight bull 330times110times20 mm 05 kg
Physical characteristicsLength of communication cablebull up to 1200 m
Character height bull ldquoImpuls-910-Rrdquo 100 mmbull ldquoImpuls-915-D4Srdquo 150 mmbull ldquoImpuls-927-D4Srdquo 270 mm
Operating temperature rangebull ldquoImpuls-910-Rrdquo 0 divide +50 degCbull ldquoImpuls-915-D4Srdquo ldquo-727-D4Srdquo minus 40 divide +50 degC
Electrical characteristicsbull Power supply 220 V 50 Hz
Mechanical characteristicsProtection index bull ldquoImpuls-910-R IP 44bull ldquoImpuls-915-D4Srdquo ldquo-727-D4Srdquo IP 65
Overall dimensions weight bull ldquoImpuls-910-Rrdquo 400times160times60 mm 3 kgbull ldquoImpuls-915-D4Srdquo 815times250times80 mm 5 kgbull ldquoImpuls-927-D4Srdquo 1250times330times80 mm 5 kg
ILLUMINATED WARNING SIGNS
ldquoIMPULSrdquo EXTERNAL DISPLAY UNIT
SPC ldquoDozardquoRadiation monitoring equipment
4544
Individual threshold setting for each measurement channel
Continuous area and process monitoring
Collect amp display data from two measurement chan-nels (units with RS-485 or analog pulses)
Audible and visual alarms on exceeding preset thresholds or status of connected devices
Individual threshold setting for each measurement channel
Switching on the external alarm or executive devices when any threshold is exceeded
The wide panel displays the following information bull Values of measured parameters as min-1∙cm-2
s-1∙cm-2 μSvhbull Diagnostic information about the status of con-
nected devicesbull Current date and timebull Position of measured values with respect to the
thresholds in the form of scales with green yellow and red zones
bull Time history (trend) for each measured value
Physical characteristics Measurement range bull Count rate up to 107 CPM (170 kHz)
Operating temperature range bull minus 20 divide +50 ordmC
Electrical characteristics bull Power supply 220 V bull Interfaces USB
Mechanical characteristics bull Protection index IP 65 bull Overall dimensions weight 222times164times73 mm
40 kg
UIM-3D AREA MONITOR COUNT RATE METER
Measurement of alpha radiation flux density
Detector unit BDZA-100 (70 cm2) Measurement range 01 divide 104 min-1∙cm-2
Detector unit BDZA-100B (300 cm2) Measurement range 01 divide 2103 min-1∙cm-2
Measurement of beta radiation flux density
Detector unit BDZB-100 (28 cm2) Measurement range 10 divide 105 min-1∙cm-2
Detector unit BDZB-100L (30 cm2) Measurement range 10 divide 104 min-1∙cm-2
Detector unit BDZB-11D (84 cm2) Measurement range 5 divide 15∙104 min-1∙m-2
OPTIONAL PROBESMeasurement of gamma radiation flux density
Detector units BDEG-03 Measurement range 4 divide 2000 s-1∙cm-2
Detector unit UDKG-100 for operation in the rocks ore liquid media and sludge Measurement range 40 divide 8000 s-1∙cm-2
Measurement of the ambient dose equivalent rate
Detector unit DBG-S11D Measurement range 01 μSvh divide 100 Svh
Measurement of neutron radiation ambient dose equivalent rate
Detector unit BDMN-100 Measurement range 01 μSvh divide 01 Svh
SPC ldquoDozardquoRadiation monitoring equipment
46 47Reference standards Nuclear IEC 61526
Measurement of gamma-radiation personal dose equivalent Hp(10)bull Stand-alone dosimeter or composed of dosimetric
system onebull Audible and visual alarmbull Large memory dose accumulation historiesbull Exclusion of unauthorized intervention in dosim-
etry operation
DKG-05D PERSONAL GAMMA DOSIMETER
Physical characteristicsDetectors bull Silicon
Measurement range bull Dose rate 1 μSvh divide 10 Svhbull Dose 01 μSv divide 15 Sv
Energy range bull 005 divide 30 MeV
Electrical characteristicsbull Power supply rechargeable NiMH battery 1
alcaline battery (type AAA)
Operation timebull Till recharging not less 400 hoursbull With one set batteries not less 1000 hours
Mechanical characteristicsOverall dimensions weight bull 47times26times87 mm (with clip) 70 g
Environmental characteristicsbull IP65bull Temperature range minus 20 divide +45 ordmCbull Humidity up to 98 at 35 ordmCbull Shock vibration and drop resistant
Alarmbull Excess of alarm thresholdsbull Warnings of self-test failure and battery discharge bull Audible alarm 80 dB at 40 cmbull Visual alarm blinking LED
Relative equipmentbull One dosimeter charger ZU-1Mbull Chargestorage cassetes KZU-28KZU-56bull ldquoSmart chargingrdquo feature extends battery life timebull DKG-05D reader US-05bull DKG-05D system reader DVS-01D
Reader-PC interfacebull US-05 USB bull DVS-01D Ethernet
KZU-28
Physical characteristicsDetectors bull Silicon Li-6
Gamma measurement range bull Dose rate 1 μSvh divide 10 Svhbull Dose 01 μSv divide 15 Sv
Gamma energy range bull 005 divide 60 MeV
Neutron measurement range bull Dose rate 1 μSvh divide 2 Svhbull Dose 20 μSv divide 15 Sv
Neutron energy range bull 0025 eV divide 20 MeV
Electrical characteristicsPower supply bull Rechargeable NiMH batterybull Operatiion time till recharging not less 200 hours
Mechanical characteristicsOverall dimensions weight bull 47times26times87 mm (with clip) 70 g
Environmental characteristicsbull IP65bull Temperature range minus 20 divide +40 ordmCbull Humidity up to 75 at 30 ordmCbull Shock vibration and drop resistant
Alarmbull Excess of alarm thresholds bull Warnings of self-test failure and battery discharge bull Audible alarm 80 dB at 40 cmbull Visual alarm blinking LED
Relative equipmentbull One dosimeter charger ZU-1Mbull Chargestorage cassetes KZU-28 KZU-56bull ldquoSmart chargingrdquo feature extends battery life timebull DVS-02D reader UZS-01Sbull DVS-02D system reader DVS-01D
Reader-PC interfacebull UZS-01S USB bull DVS-01D Ethernet
UZS-01DReference standards Nuclear IEC 61526
DVS-02D GAMMA-NEUTRON PERSONAL ELECTRONIC DOSIMETER
Measurement of gamma- and neutron radiations personal dose equivalent Hp(10)bull Stand-alone dosimeter or composed of dosimetric
system onebull Audible and visual alarmbull Large memory dose accumulation historiesbull Exclusion of unauthorized intervention in dosim-
etry operationbull Both albedo thermal neutrons and intermediate
fast neutrons registrationbull Usable in the fields of Pu(Be) Po(Be) Cf and other
neutron sources as well as near nuclear reactors without neutron spectrum estimation
SPC ldquoDozardquoRadiation monitoring equipment
48 49
Dosimeters DVG-03D
DVGI-8D NEW PEN-TYPE PERSONAL IONIZATION CHAMBER DOSIMETERS
Measurement of personal dose equivalent Hp(10) of gamma and X-ray radiationbull Hp(10) of continuous and pulsed gamma and
X-ray radiation bull Electronic reader KSU-1bull Dosimeter DVG-03D with electronic ID bull Personal dose histories in the readerrsquos memorybull Readerrsquos connection with PC for database main-
tenance
Physical characteristicsDetector bull Ionization chamber
Measurement range bull 001 mSv divide 25 mSv
Energy range bull 0015 divide 25 MeV
Temperature range bull Reader KSU-1 +10 divide +50 ordmСbull Dosimeter DVG-03D minus 40 divide +50 ordmС
Electrical characteristicsPower supply bull Reader KSU-1 220 V 50 Hz built-in batteries bull Dosimeter DVG-03D four batteries CR 1025 bull Batteries life 3 yearsbull Readers interfaces RS-232USB 20
Mechanical characteristicsOverall dimensions weightbull Dosimeter DVG-03D Oslash 18times126 mm 005 kgbull Reader KSU-1 235times232times125 mm 28 kg
Reference standards Nuclear IEC 62387-1
DKG-02U ldquoARBITERrdquo WIDE RANGE GAMMA-DOSIMETER
Physical characteristicsDetectors bull GM counters
Measurement rangebull Dose-rate 01 μSvh divide 3 Svhbull Dose 1 μSv divide 100 Sv
Energy range bull 005 divide 3 MeV
Electrical characteristicsbull Power supply 2 alcaline batteries (type AA)bull Batteries life not less 200 hours
Mechanical characteristicsOverall dimensions weight bull 152times82times32 mm 03 kg
Environmental characteristicsbull Temperature range minus 20 divide +50 ordmCbull Humidity up to 90 at +25 ordmCbull Shock vibration and drop resistant
Reference standards Nuclear IEC 60846
Measurement of gamma radiation ambient equiva-lent dose H(10) and dose rate H(10)bull Audible signals (clicks) for radiation condition
estimationbull Analog scale for search modebull Audible and visual alarms of the excess of preset
dose and dose rate thresholds bull Shock-resistant water-proof easy decontamina-
tion casebull 100 measurement results memory with date and
time of measurementbull Indication of total dose accumulated during
exploitation time bull Indication of measurement result statistical
uncertainty
SPC ldquoDozardquoRadiation monitoring equipment
50 51
Physical characteristicsDetectors bull GM counter
Measurement rangebull Dose-rate 01 μSvh divide 3 mSvhbull Dose 1 μSv divide 02 Sv
Energy range bull 005 divide 3 MeV
Temperature range bull Minus 20 divide +50 ordmC
Electrical characteristicsbull Power supply 2 alcaline batteries 15 V (type AA)bull Batteries life not less 200 hours
Mechanical characteristicsOverall dimensions weight bull 122times74times29 mm 025 kg
Reference standards Nuclear IEC 60846
DKG-07D ldquoDROZDrdquoGAMMA-DOSIMETER
Measurement of gamma radiation ambient equiva-lent dose H(10) and dose rate H(10)bull Two independent measurement channels dose
and dose ratebull Audible signals (clicks) for radiation condition
estimationbull Continuous measurement with updating meas-
urement resultbull Measurement result can be obtained with any
desired statistical uncertainty (error)bull Automatic restart when radiation level sharply
changesbull Indication of statistical uncertainty (error) during
measurement process
Continuous measurement with updating measure-ment result
Automatic restart when radiation level sharply changes bull Gamma dose H(10) and dose-rate H(10) meas-
urementbull Beta and gamma contamination surveybull Indication of statistical uncertainty during the
measurementbull Continuous measurement with accuracy increas-
ing with time bull Automatic restart triggered by change of gamma
dose-ratebull Compensation of gamma count rate while meas-
uring beta radiationbull Indication of battery charge levelbull Audible signal of the excess of preset threshold
Physical characteristicsDetectors bull GM counter
Measurement range bull Dose-rate 01 microSvh divide 20 mSvhbull Dose 1 microSv divide 100 Svbull Beta flux density (for Sr-90+Y-90)
10 divide 105 cm-2 min-1
Energy range bull Gamma 005 divide 3 MeVbull Beta 01 divide 3 MeV
Temperature range bull Minus 20 divide +50 ordmC
MKS-15D ldquoSnegirrdquo backside
MKS-15D ldquoSNEGIRrdquoMULTI ndash PURPOSE RADIATION SURVEY METER
Reference standards Nuclear IEC 60846 IEC 60325
Electrical characteristicsbull Power supply 2 alcaline batteries (type AA)bull Battery life not less 400 hours
Mechanical characteristicsOverall dimensions weight bull 124times72times35 mm 035 kg
SPC ldquoDozardquoRadiation monitoring equipment
52 53
Physical characteristicsDetectorbull GM counter
Measurement range bull 01 μSvh divide 20 mSvh
Energy range bull 005 divide 30 MeV
Threshold setting range bull 03 μSvh divide 20 mSvh
Step change of the thresholdbull In the range 03 divide 10 μSvh with the step
001 μSvhbull In the range 10 divide 100 μSvh with the step
01 μSvhbull In the range 100 divide 2000 μSvh with the step
10 μSvh
Electrical characteristicsPower supply bull 220 V 50 Hz bull Relay output
Mechanical characteristicsProtection index bull IP 40
Overall dimensions weight bull 226times120times75 mm 07 kg
Alarmbull Sound alarm 80 divide 100 dBA at distance 1 mbull Visual alarm redbull Connection of the external alarm signaling unit
Reference standards Nuclear IEC 60846 IEC 60532
Continuous automatic monitoring of the ambient dose equivalent rate bull Measurement of gamma dose rate H(10)bull Audible and visual alarm signals for preset
thresholdsbull Switching on the external signaling or executive
devices
SRPS-05D GAMMA MONITOR
Measurement ofbull Gamma and X-ray personal dose equivalent
Hp(10)bull Neutron personal dose equivalent Hp(10)bull Lens dose equivalent Hp(3)bull Skin dose equivalent Hp(007)bull TLD reader day-to-day tests using built-in LEDbull No needs nitrogen for heating
Physical charachteristicsDetectors bull 7LiF Mg Ti (gamma beta)bull 6LiF Mg Ti (neutron)
Gamma and X-ray Hp(10) Measurement range bull 500 μSv divide 10 Sv
Energy range bull 0015 divide 30 MeV
Neutron Hp(10)Measurement range bull 01 mSv divide 100 mSv
Energy range bull 0025 eV divide 10 MeV
Beta and photons Hp(007) Hp(3) Measurement range bull 2 mSv divide 100 Sv
Energy range bull Beta 025 divide 35 MeVbull Photons lt15 keV
Mechanical characteristicsDosimeters overall dimensions weight bull Gamma Hp(10) DTL-2 holder - 62times26times16 mm
16 gbull DTU holder - 42times28times18 mm 8 gbull Lens Hp(3) face skin Hp(007) Oslash 32times16 mm 9 gbull Finger skin Hp(007) 90times20times2 mm 1 gbull Neutron gamma Hp(10) 48times40times20 mm 30 g
Reference standards Nuclear IEC 61066
DTL-2 DTU-2
MKD (A-type) DVNG-M
DOZA-TLD MULTIPURPOSE TLD SYSTEM
SPC ldquoDozardquoRadiation monitoring equipment
54 55
Continuous and pulsed gamma and X-ray dose H(10) and dose-rate measurementbull Alpha beta and gamma contamination surveybull Neutron dose H(10) and dose-rate measurementbull Gamma radiation flux density in boreholes and
liquid media measurement
Electrical characteristicsPower supply bull UIK-05 four C-size batteriesbull UIK-05-01 rechargeable batterybull UIK-06 rechargeable battery
Interfaces bull RS-232bull USB (via adapter)
bull Detector type automatic determination and corre-sponding measurement modes selection
bull Alarm threshold settings ndash for dose dose-rate alpha and beta contaminations
bull ldquoDetectrdquo and ldquoLocaterdquo modes for survey probes
Reference standards Nuclear IEC 60846 IEC 60325 IEC 61005 IEC 62363
Case
UIK-06 control unit165times78times48 mm 03 kg
DKS-96UNIVERSAL RADIATION SURVEY METER
UIK-05 control unit202times86times90 mm 10 kg
BDZA-96
BDZA-96B
BDZA-96M
BDZA-96S
BDZA-96T
EXTERNAL PROBES ALPHAALPHA BDZA-96Detector bull ZnS(Ag) 70 cm2
Measurement range (for Pu-239)bull 01 divide 104 min-1cm-2
Overall dimensions weightbull Oslash 130times240 mm 11 kg
ALPHA BDZA-96BDetector bull ZnS(Ag) 300 сm2
Measurement range (for Pu-239)bull 01 divide 2103 min-1cm-2
Overall dimensions weightbull Oslash 230times290 mm 40 kg
ALPHA BDZA-96MDetector bull ZnS(Ag) 10 сm2
Measurement range (for Pu-239)bull 01 divide 105 min-1cm-2
Overall dimensions weightbull Oslash 65times240 mm 09 kg
ALPHA BDZA-96SDetector bull ZnS(Ag) 30 сm2
Measurement range (for Pu-239)bull 01 divide 5104 min-1cm-2
Overall dimensions weightbull Oslash 90times240 mm 10 kg
ALPHA BDZA-96TDetector bull Silicon 5 сm2
Measurement range (for Pu-239)bull 01 divide 106 min-1cm-2
Overall dimensions weightbull Oslash 50times60 mm 015 kg
SPC ldquoDozardquoRadiation monitoring equipment
56 57
BETA BDZB-96Detector Scintillator 28 сm2
Measurement range (for Sr-90+Y-90)bull 10 divide 105 min-1cm-2
Energy rangebull 03 divide 30 MeV
Overall dimensions weightbull Oslash 90times230 mm 09 kg
BETA BDZB-99Detector bull GM counter 30 сm2
Measurement range (for Sr-90+Y-90)bull 20 divide 104 min-1см-2
Energy rangebull 012 divide 30 MeV
Overall dimensions weightbull Oslash 88times80 mm 04 kgbull Telescopic pole length 07 m
BETA BDZB-96BDetector bull GM counter 80 сm2
Measurement range (for Sr-90+Y-90)bull 3 divide 104 min-1сm-2
Energy rangebull 012 divide 30 MeV
Overall dimensions weightbull 150times200times110 mm 15 kg
BETA BDZB-96Sbull Detector GM counter 15 сm2
Measurement range (for Sr-90+Y-90)bull 10 divide 3104 min-1cm-2
Energy rangebull 012 divide 30 MeV
Overall dimensions weightbull Oslash 65times65 mm 03 kgbull Telescopic pole length 07 m
BDZB-96
BDZB-99
BDZB-96B
BDZB-96S
EXTERNAL PROBES BETA
GAMMA BDKS-96BDetector bull Tissue-equivalent scintillator Oslash 45times20 mm
Measurement rangebull Dose rate H(10) 01 μSvh divide 1 Svhbull Dose H(10) 01 μSv divide 10 Sv
Energy rangebull 0015 divide 10 MeV
Overall dimensions weightbull Oslash 60times250 mm 085 kg
GAMMA AND BETA BDKS-96SDetector bull Double GM counters
Measurement rangebull Gamma dose rate H(10) 01 μSvh divide 1 mSvhbull Gamma dose H(10) 01 μSv divide 10 Svbull Beta 10 divide 3104 min-1cm-2
Energy rangebull Gamma 005 divide 3 MeVbull Beta 012 divide 3 MeV
Overall dimensions weightbull Oslash 80times80 mm 035 kgbull Telescopic pole length 07 m
GAMMA BDMG-96Detector bull GM counters
Measurement rangebull Dose rate H(10) 01 μSvh divide 10 Svhbull Dose H(10) 01 μSv divide 10 Sv
Energy range bull 005 divide 3 MeV
Overall dimensions weightbull 40times250 mm 05 kgbull Telescopic pole length 07 m 4 m (by request)
EXTERNAL PROBES GAMMA
BDKS-96B
BDMG-96
BDKS-96S
SPC ldquoDozardquoRadiation monitoring equipment
58 59
GAMMA-SEARCH BDVG-96Detector bull Scintillator NaI(Tl) Oslash 63times63 mm
Measurement rangebull Flux density measurement range 4 divide 2000 s-1cm-2
bull Dose rate H(10) for Cs-137 01 divide 30 μSvhbull Sensitivity for Cs-137 3000 (pulsess-1)( μSvh-1)
Overall dimensions weightbull Oslash 88times400 mm 20 kgbull Modular pole length 16 m
GAMMA-SEARCH BDPG-96Detector bull Scintillator NaI(Tl) Oslash 25times40 mm
Measurement rangebull Flux density measurement range 10 divide 8000 s-1cm-2
bull Dose rate H(10) for Cs-137 01 divide 100 μSvhbull Sensitivity for Cs-137 500 (pulsess-1)( μSvh-1)
Overall dimensions weightbull 50times190times480 mm 10 kgbull Telescopic pole length 07 m
GAMMA-SEARCH BDPG-96MDetector bull Scintillator NaI(Tl) Oslash 18times30 mm
Measurement rangebull Flux density measurement range 10 divide 24000 s-1cm-2
bull Dose rate H(10) for Cs-137 01 divide 300 μSvhbull Sensitivity for Cs-137 200 (pulsess-1)( μSvh-1)
Overall dimensions weightbull Oslash 35times320 mm 05 kgbull Telescopic pole length 07 or 38 m
EXTERNAL PROBES GAMMA
BDVG-96
BDPG-96M
BDPG-96
EXTERNAL PROBESGAMMA BDKG-96 STAINLESS STEEL CASING FOR GEOLOGIC APPLICATIONS WELL LOGGINGDetector bull Scintillator NaI(Tl) Oslash 18times30 mm
Measurement rangebull Flux density measurement range 10 divide 105 s-1cm-2
bull Dose rate H(10) for Cs-137 5 divide 2104 μRhbull Sensitivity for Cs-137 200 (pulsess-1)( μSvh-1)
Overall dimensions weightbull Oslash 38times535 mm 36 kgbull Cable length 10 divide 1000 m
NEUTRON BDMN-96Detector bull Scintillator with ZnS(Ag)
Measurement rangebull Dose rate H(10) 01 μSvh divide 01 Svhbull Dose H(10) 01 μSv divide 10 Sv
Energy range bull 0025 eV divide 10 MeV
Overall dimensions weightbull Detector Oslash 54times200 mm 08 kgbull Moderator Oslash 245 mm 73 kg
NEUTRON-SEARCH BDKN-96Detector bull He-3 counter in polyethilene moderator
Measurement rangebull Dose rate H(10) for Pu-Be 01 μSvh divide 01 Svhbull Dose H(10) for Pu-Be 01 μSv divide 10 Sv
Energy range bull 0025 eV divide 14 MeV
Overall dimensions weightbull 295times142times100 mm 225 kg
BDKG-96M
BDMN-96
BDKN-96
SPC ldquoDozardquoRadiation monitoring equipment
60 61
bull No gas supply neededbull Clothing control detachable right hand detector bull Alpha detector optional connection bull Numeric and color (red green) indication of
control resultsbull LED sensor of hand-foot positioning for start of
measurementbull Automatic compensation of gamma background
and contamination of detectorbull Audible alarm signals of the excess of preset
thresholdsbull Measurement value indication min-1cm-2 or
Bqсm2
Reference standards Nuclear IEC 61098
RZB-05D HAND-FOOT-CLOTHING MONITOR
Physical characteristicsDetectors bull Gamma beta - GM countersbull Alpha - scintillatior ZnS(Ag)
Detecting nuclidesbull Alpha Pu-239 U-234 U-238bull Beta Sr-90+Y-90 F-18 Cs-137 Co-60 Tс-99 O-15
N-13 Sr-89 C-11 I-131 Na-22 Ru-106+Rh-106 Tl-204
bull Gamma Tc-99m I-123
Efficiencybull Alpha
Pu-239 40 U-234 25U-238 15
bull Beta Sr-90 +Y-90 40
Measurement range bull Alpha 1 divide 103 min-1cm-2 bull Beta 10 divide 103 min-1cm-2
bull Gamma 5103 divide 5106 min-1cm-2
Energy range bull Alpha 30 divide 80 MeV bull Beta 008 divide 35 MeV bull Gamma 005 divide 30 MeV
Operation temperature range bull Minus 10 divide +50 ordmС
Electrical characteristicsbull Power supply 220 V 50 Hz
Mechanical characteristicsOverall dimensions weight bull 740times750times1180 mm 45 kg
Versionsbull Withwithout alpha detectorbull Indication (min-1cm-2 ) or (Bqсm2)bull Detectors overall dimensions smbull Hand 178 х 235bull Foot 185 х 436
Whole body contamination monitor RZBA-04-04Mbull No gas supply neededbull Compensation for background gamma radiation
and contamination of detector unitsbull Individual threshold setting for each measure-
ment channelbull Visible and audible alarms ldquoCONTAMINATIONrdquo and
ldquoCLEANrdquo bull Indication of contaminated body parts on the
panel with image of the bodybull Optional remote alpha-detector
Physical characteristicsDetectors bull Beta - GM counters scintillatorsbull Alpha - scintillatior ZnS(Ag)
Measurement range bull Beta 5 divide 15000 min-1cm-2
bull Alpha 01 divide 10000 min-1cm-2
Energy range bull Beta 015 divide 25 MeV bull Alpha 40 divide 56 MeV
Operation temperature range bull +5 divide +50 ordmС
Electrical characteristicsPower supply bull 220 V 50 Hz
Interfaces bull RS-232bull RS-485
Mechanical characteristicsOverall dimensions weight bull 2650times940times930 mm 310 kg
Versionsbull Withwithout alpha detectorbull Indication (min-1cm-2 ) or (Bqсm2)
Reference standards Nuclear IEC 61098
RZBA-04-04MWHOLE BODY CONTAMINATION MONITOR
SPC ldquoDozardquoRadiation monitoring equipment
62 63
RZA-05DALPHA HAND-MONITOR
bull No gas supply needed bull Numeric and color (red green) indication of
control resultsbull LED sensor of hand- positioning for start of
measurementbull Audible alarm signals of the excess of preset
thresholdsbull Measurement value indication min-1cm-2 or
Bqсm2
Physical characteristicsDetectors alpha - scintillatior ZnS(Ag)
Efficiencybull Pu-239 20 bull U-234 14bull U-238 8
Measurement range bull 05 divide 105 min-1cm-2
Energy range bull 41 divide 90 MeV
Operation temperature range bull minus 10 divide +50 ordmС
Electrical characteristicsPower supply bull 220 V 50 Hz
Mechanical characteristicsOverall dimensions weight no more bull 740times1400times1450 mm 70 kg
Reference standards Nuclear IEC 61098
bull Simultaneous measurement of alphabeta activi-ties in the sample
bull Active shielding anti-coincidence background subtraction using GM counters
bull Lead shielding 30 mm
UMF-2000 LOW LEVEL ALPHA- BETA- COUNTER
Physical characteristicsDetectors bull Silicon specrometric detector 500 or 1000 mm2
Measurement range bull Alpha 001 divide 1000 Bq bull Beta 01 divide 3000 Bq
Energy range bull Alpha 35 divide 80 MeV bull Beta 005 divide 35 MeV
Electrical characteristicsPower supply bull 220 V 50 Hz
Interfaces bull RS-232bull USB
Mechanical characteristicsOverall dimensions weight bull 337times286times190 mm 22 kg
Versionsbull Detector area 500 mm2
bull Detector area 1000 mm2
UMF-2000 Detector area 1000 mm2
UMF-2000 Detector area 500 mm2
SpectraDec software for alpha-spectrometric measurements
SPC ldquoDozardquoRadiation monitoring equipment
64 65
DRK DOSE AREA PRODUCT METER
DRK-1bull Diagnostic reference level (DRL) of patients
determinationbull Suitable for all basic types of x-ray machines
Physical characteristicsDetector bull Plane-parallel ionization chamber
Measurement range bull 1 divide 104 cGycm2
Electrical characteristicsPower supply bull 220 V 50 Hz
DRK-1M-CTbull Measuring of dose length product
Physical characteristicsDetector bull Pencil Ionization Chamber
Measurement rangebull 05 divide 109 microGym
DRK-1Mbull Measuring of air kerma on sectional area of the
X-ray beam productbull Measuring of air kerma rate on area productbull Measuring of air kerma ratebull Measuring of air kerma
Physical characteristicsDetector bull Plane-parallel ionization chamber
Measurement rangebull 01 divide 109 microGym2
bull 06 divide 6104 microGym2cbull 30 divide 9105 microGycbull 30 divide 9991011 microGyReference standard IEC 60580 2003
bull Measurement of strontium-90 in the foodstuffs agricultural products etc
bull Measurement of gross beta activity in samplebull Self tests using built-in LED
ldquoPROGRESS-BETArdquo SCINTILLATION BETA SPECTROMETER
Physical characteristicsDetector bull Plastic scintillator Oslash70x10 mm
Sample bull Plate Oslash70 mmbull Weight up to 15 g
Energy range bull 02 divide 30 MeV
Minimum detectable activity of Sr-90 in a 10 g sample on a standard planchet Bqsamplebull In case of absence of K-40 in the sample 01 Bqbull In case the activity of K-40 till 5 Bqg 05 Bq
Electrical characteristics Interface bull USB
Mechanical characteristicsWeight bull No more 50 kg
Complete setBasic complete setbull Detector unit with plastic scintillator integrated
power supply amplifier ADC bull Lead shielding bull ldquoProgressrdquo software bull Сheck source for energetic calibration (Sr-90-Y-90) bull Planchet Oslash 70 mm (5 items) bull Sample dencification device bull Procedure manual for measurement of radio-
nuclidesrsquo activity using the scintillation beta spec-trometer ldquoProgressrdquo
Optional equipment and servicebull Personal computer and printer bull Calibrations for radionuclides not included in the
main library of radionuclides
Progress-Beta
Reference standards IEC 61562
SPC ldquoDozardquoRadiation monitoring equipment
66 67
bull Measurement of gamma activity in foodstuffs soil samples and others environmental objects
bull Identification of radionuclides in the sample bull Automatic correction for sample density bull Self-tests using built-in LED
ldquoPROGRESS-GAMMArdquoSCINTILLATION GAMMA SPECTROMETER
Physical characteristicsDetector bull NaI (Tl) Oslash63times63 mm
Validated measurement geometries bull Marinelli beakers (1 liter) Petri dishes (Oslash90 mm)
etc
Energy range bull 02 divide 30 MeV
Minimum detectable activity Bqsamplebull Cs-137 3 Bqbull Th-232 7 Bqbull Ra-226 8 Bq bull К-40 40 Bq
Electrical characteristics Interface bull USB
Mechanical characteristicsWeight bull No more 120 kg
Complete setBasic complete setbull Scintillation detector unit with NaI (Tl) detector
with integrated power supply amplifier and ADC bull Lead shielding 50 mm bull ldquoProgressrdquo software bull Сheck source for energy calibration (Cs-137 +
K-40)bull Marinelli beakers - 1 liter (5 items) bull Petri dishes Oslash 90 mm (5 items) bull Procedure manual for measurement of activity
of radionuclides using the scintillation gamma spectrometer ldquoProgressrdquo
Optional equipment and servicebull Kit for radon measurements including calibration
of ldquoIC-63rdquo geometry for counting the charcoal samples
bull Personal computer and printer bull Calibrations for user defined geometries bull Calibrations for radionuclides not included in the
main library of radionuclides
Progress-Gamma
Reference standards IEC 61563
ldquoPROGRESS-G(P)rdquoPORTABLE SCINTILLATION GAMMA SPECTROMETERbull Field measurements of gamma activity in environ-
mental objects without sampling (4π geometry)bull Laboratory measurement of gamma activity in
foodstuffs soil samples and others environmental objects
bull Identification of radionuclides in the sample bull Automatic correction for sample densitybull Tests using built-in LED
Physical charachteristicsDetector bull NaI (Tl) Oslash45times50 mmbull Lead shielding 20 mm
Validated measurement geometries bull Marinelli beakers (05 liter) Petri dishes (Oslash90 mm)
etc
Energy range bull 02 divide 30 MeV
Minimum detectable activity in 05-litre Marinelli beaker bull Cs-13710 Bqkgbull К-40100 Bqkgbull Ra-22618 Bqkg bull Th-23216 Bqkg
Minimum detectable activity in 30 min (4π geometry) bull Cs-137 2 Bqkgbull К-40 30 Bqkgbull Ra-226 4 Bqkg bull Th-232 3 Bqkg
Electrical characteristicsPower supply bull Rechargeable batterybull 220 V 50 Hz
Interface bull USB RS-232
Weight bull No more than 60 kg
Complete setBasic complete setbull Scinttillation detector unit with NaI(Tl) bull ldquoProgressrdquo softwarebull Сontrol unit ldquoSputnikrdquo for aquisition and analisys
of spectra with built-in memory for spectral databull Casebull Lead shielding (2 cm) for laboratory usebull 05-litre Marinelli beakers ndash 5 itemsbull Na-22 check sourcebull Power adapter BPS-01bull Operation manualbull Procedure manual for measurement of activity
of radionuclides using the scintillation gamma spectrometer ldquoProgressrdquo
Optional equipment and servicebull Kit for radon measurements with charcoalbull Built-in dose rate meterbull Additional memory (RAM) for storage of 64
spectrabull Additional power adapterbull Notebook and printer
Progress-Gamma
Reference standards IEC 61563
SPC ldquoDozardquoRadiation monitoring equipment
68 69
Physical characteristicsDetectorbull Scintillation detector ZnS (Oslash 60 mm)
Samplebull Thin sample - diameter up to 70 mm bull Preparation technique - electro-depositionbull Thick sample - diameter 70 mm weight
200300 mg bull Preparation technique - application of powders
(prepared by radiochemical concentration by water evaporation or by pounding of mineral samples) onto a planchet with the help of spirit
Energy rangebull 15 divide 8 MeV
Minimum detectable activitybull Thin samples no more than 910-3 Bqsamplebull Thick samples no more than 180 Bqkg
Mechanical characteristicsOverall dimensions weightbull 195times120times210 mm 34 kg
Complete setBasic complete setbull Alpha radiometer ldquoProgress-ARrdquobull Check source (uranium isotopes)
Set of accessoriesbull Procedure manual for measurements of radi-
oactivity using scintillation alpha radiometer ldquoProgress-ARrdquo
bull ldquoProgressrdquo software
ldquoProgress-ARrdquo
bull Measurement of gross activity of alpha emitting radionuclides in thin samples
bull Measurement of gross activity of alpha emitting radionuclides in thick samples
bull Measurement of activity deposited on aerosol filters
ldquoPROGRESS-ARrdquoALPHA RADIOMETER
Several fixed positions of the detector enable to perform measurements in various geometries and to estimate the content ofbull Cs-137 in the whole bodybull I-131 in thyroidbull Co-60 Cs-137 Mn-54 Cr-51 in lungsbull Database for storage of measurement data and
resultsbull Uncertainty calculations based on measurement
databull Self tests using built-in LED
ldquoPROGRESSrdquo WHOLE BODY COUNTER
Physical characteristicsDetectorbull scintillation detector NaI (Tl) Oslash63times63 mm
Energy rangebull 02 divide 28 MeV
Minimum detectable activitybull By Cs-137 in the whole body - 1200 Bqbull By I-131 in thyroid - 100 Bqbull By Co-60 Cs-137 Mn-54 Cr-51 in lungs - 200 Bq
Mechanical characteristicsWeight bull No more than 120 kg
Complete setBasic complete setbull Collimator with rotator and holderbull Detector with incorporated ADCbull Patient chair and table for collimatorbull Check source Na-22bull Procedure manual for lifetime measurement of
gamma-emitting radionuclidesrsquo activity in human body using the gamma-spectrometer of human radiation ldquoProgressrdquo
bull laquoProgressraquo software
Optional equipment and servicebull Program of internal radiation committed internal
radiation effective dose calculation by the stand-ard model
bull Background phantombull Personal computer and printer
Collimator with rotator and holder
SPC ldquoDozardquoRadiation monitoring equipment
70 71
bull Categorization of wastes for the purpose of fur-ther processing including wastes with unknown radionuclide composition
bull Measurements during the incoming waste inspec-tion (accepting for storage disposal)
bull Certification of unconditioned and conditioned wastes in closed containers without opening them (at nuclear plants or at facilities providing collection storage transportation conditioning processing temporal storage and final disposal of radioactive waste)
bull Activity measurement of extended objects in situ without opening the equipment
bull Activity measurement of extended objects after opening (for example assessment of tubes used for oil transportation)
MKG-01D ldquoSADOVNIKrdquoSPECTROMETRY SYSTEM
Physical charachteristicsDetectorbull Detector unit GEM (GMX) with HPGe detector and
multi-positioning cryostat CFG-PMOD4-7 with 7 litre Dewar
bull Dose rate probe BDMG-200
Energy range bull With GEM detector 004 divide 30 MeVbull With GMX detector 0005 divide 15 MeVbull Dose rate probe BDMG-200 ndash 005 divide 30 MeV
Measurement rangebull 110-7 divide 10 Svhbull Relative efficiency of detection (in photopeak) at
13325 MeV (Co-60) 10 divide 150
Electrical characteristicsPower supplybull 220 V 50 Hz
Interfacebull USB
Complete setBasic complete setbull Spectrometric detector unit GEM (GMX) with
HPGe detector and multi-positioning cryostat with 7 litre Dewar
bull Portable digital multichannel analyzer DigiDARTbull Dose rate probe BDMG-200bull Autonomous power supply unit with built-in
batterybull Industrial computer keyboardbull Laser range-finderbull Thermographic printerbull Web-camerabull Device equipped with stepper motor for position-
ing of the spectrometric detectorbull Calibration device with reference sources
(Am-241 Co-60 Ba-133 Eu-152) for energy calibration
bull Removable collimators with end capbull Measurement proceduresbull ldquoClasterrdquo software
bull Measurement of gross alpha activity of alpha-emitting radionuclides
bull Measurement of alpha-emitting radionuclides activity in thin-layer samples meeting alpha-spectrometry requirements
Physical characteristicsDetectorbull Silicon ion-implanted 450 mm2
bull Easy to decontaminate thin windowbull dead layer less than 015 μmbull Background count rate in the range 3 divide 9 MeVbull No more than 09 h-1cm-2 for 450 mm2 detector
Energy rangebull 2 divide 9 MeVbull Lower limit of measurement range (minimum
detectable activity) 01 Bqbull Background count rate no more than 100 counts
in 24 hours
Electrical characteristics Power supplybull 220 V 50 Hz
Interfacebull USB
Complete setBasic complete setbull Detector unit with vacuum measuring chamber
and vacuum control systembull Low noise vacuum pump (type 2FY-05B or
equivalent)bull Check sourcebull ldquoProgressrdquo softwarebull Vacuum tube
MKS-01A ldquoMULTIRAD-ASrdquoALPHA SPECTROMETER
SPC ldquoDozardquoRadiation monitoring equipment
72 73
UCRV-2AIRFLOW MONITOR
bull Monitor of the air flow through filter of centralized multichannel sampling system
bull Radiation monitoring system (RMS) integration for internal exposures determination
bull Volume and flow rate measurements of the air that have passed through a analytical filter
bull Bar-code for filter identificationbull Operation as either standalone unit or as a part of
the RMS
Physical characteristicsMeasurement range of air volume bull 001 divide 9999 m3
Operation temperature range bull minus 20 divide +50 ordmС
Electrical characteristicsPower supply bull 220 V 50 Hz
Interface bull RS-485
PVP-06PORTABLE AIR SAMPLER
Air Sampler PVP-06 is indispensable for monitoring the radiation situation where the concentration of radioactive aerosols in the air does not require a sta-tionary sampling equipment Sampling head PVP-06 provides easy change of filters and cartridges
Purposebull To monitor the concentration of radioactive aero-
sols in the air sites
Controlled aerosolsbull Alpha- and beta-active aerosolsbull Daughter products of decay of radon and thoronbull Iodine isotopes
Physical characteristicsTypes of filtersbull Aerosol AFA-RSP-20bull Iodine AFA SI-20
Flow rate bull 33∙10-4 ndash 233∙10-4 m3s (20 divide 140 l min)
Electrical characteristicsPower supply bull 220 V50 Hzbull The vehicle power supply 108 divide 145 Vbull Internal battery
Minimal working time on internal battery to recharge bull 8 hours
Power consumption (at a flow rate of 100 lmin) bull 40 VA
Environment characteristicsOperating temperature bull minus 10 divide +40 deg C
Maximum humidity bull 90
Pressure bull 860 to 1060 hPA
Noise generated by the pump bull lt 55 dBA at 1 m
Mechanical characteristicsDimensions weight bull 241 times 108 times 160 mm 28 kg
Case material bull Plastic
Complete setbull Air sampler PVP-06bull AC power adapterbull Filters AFA-RSP-20 - 100 pcsbull Packaging for filters - 40 pcsbull Casebull Operation manualbull Calibration certificate
Optional equimpient bull Kit for sampling sorption columns of activated
carbon Ř head of sorption columns with protective
covers Ř activated charcoal SKT-3 - 1 pkg (02 L) Ř charocoal samples SC-13 - 8 pcs
bull Car charger bull Tipod bull Shoulder strapbull Calibration stand bull Filters AFA SI-20 - 100 pcs
Consumablesbull Aerosol filters AFA RSP-20bull Iodine filters AFA SI-20
SPC ldquoDozardquoRadiation monitoring equipment
74 75
Calibration of gamma dose and dose rate meters
Calibration ofbull Ambient equivalent dose H(10) meters (Sv Svh)bull Personal equivalent dose Hp(10) meters (Sv Svh)bull Exposure dose X meters (R Rh)bull Two sources in irradiator bull Select source and collimator opening using
tumbler
UPG-P DESKTOP GAMMA BEAM IRRADIATOR
Physical characteristicsRange of reproduced dose rate bull 05 μSvh divide 10 mSvh (50 μRh divide 100 mRh)
Sources activities bull 6times106 6times108 Bq (02 20 mCi) Cs-137
Overall dimensions bull 1250times400times300 mm
Irradiator weight bull Not more than 37 kg
Calibration bench weight bull Not more than 15 kg
Reference standards IEC 60846 IEC 61526
Physical characteristicsDetectorbull Silicon
Measurement range EEC measurement bull Measurement range of radon EEC
10 divide 10bull106 Bqbullm-3
bull Measurement range of thoron EEC 05 divide 10bull104 Bqbullm-3
bull Air flow through the filter 100plusmn05 lmin
Concentration measurementbull Measurement range of radon-222 concentration
in air 10 divide 20bull106 cpsbull Measurement range of 216Po(ThA)
1bull10-3 divide 1bull102 cpsbull Air sampler flow rate
10plusmn02 lminbull Measurement range of radon-222 concentration
in water samples 6 divide 800 Bqbullkg-1
bull Measurement range of radon-222 flux from soil surface 20 divide 103 mBqsbullm2
bull Measurement range of radon-222 concentration with preliminary sampling of air using air sam-plers 20 divide 107 Bqbullm-3
bull Measurement range of radon-222 concentration in samples of soil air 103 divide 106 Bqbullm-3
Operation temperature range bull 1 divide 35 ordmC
Electrical characteristicsPower supply bull 80 VA
Mechanical characteristicsOverall dimensions weight bull 220times200times165 mm 36 kg
ldquoALPHARAD PLUSrdquoRADON THORON amp THEIR PROGENY MONITORbull Measurement of radon and thoron concentration
and effective equivalent concentration (EEC)bull In the airbull In the indoor air of residential public and industri-
al buildings and structuresbull Measurement of radon in drinking water sourcesbull Measurements of radon flux from the soil surface
at land plots allocated for construction of houses public buildings and industrial facilities
bull Measurements of radon concentration in soil air
Reference standards IEC 61577
SPC ldquoDozardquoRadiation monitoring equipment
76 77
UKPN-2M-D NEUTRON BEAM IRRADIATOR
Reference standards IEC 61005 61322
Calibration of neutron dose and dose rate meters
Calibration ofbull Ambient equivalent dose H(10) meters (Sv Svh)bull Personal equivalent dose Hp(10) meters (Sv Svh)bull Flux density of neutrons (cm-2∙s-1)bull Transfer container for temporary storage of
sources bull Red light signal of source working position
Physical carachteristicsRange of reproduced dose ratebull 20 divide 800 μSvh
Range of reproduced flux densitiesbull 10 divide 400 cm-2∙s-1
Type of a source in use bull Pu-Be
Activity of a source in usebull 24х1011 Bq (with density of 107 s-1)
Overall dimensions weight no morebull 3000x750x2000 mm 300 kg
Required room dimensionsbull not less than 7x3x3 m
Electrical characteristicsPower supply bull 220 V 50 Hz
Calibration of gamma dose and dose rate meters
Calibration ofbull Ambient equivalent dose H(10) meters (Sv Svh)bull Personal equivalent dose Hp(10) meters (Sv Svh)bull Exposure dose X meters (R Rh)bull Four sources in irradiator bull Select source and move to working position
return to storage position using special rodbull Transfer container for temporary storage of
sources bull Red light signal of source working position
UPGD-2M-DGAMMA BEAM IRRADIATOR
Physical characteristicsRange of reproduced dose rate bull 05 μSvh divide 50 mSvh (50 μRh divide 5 Rh)
Maximum activity of source bull 2times1011 Bq (50 Ci) Cs-137
Overall dimensionsbull Irradiator 800times500times500 mmbull Guide rails length 30 mbull Height 16 mbull Weight not more than 700 kgbull Required room dimensions not less than 7x3x3 m
Electrical characteristicsPower supply bull 220 V 50 Hz
UPGD-2M-D
Reference standards IEC 60846 IEC 61526 IEC 61066
SPC ldquoDozardquo
78 79
Contents
MEASURING UNITS
DBG-S11D wide range gamma area monitor 40
UDKS-100 gamma and X-ray area monitor 41
UDMN-100 neutron area monitor 41
ALARM UNITS
BAS-2 ldquoMICROrdquo external visual alarm 42
BZS-2 ldquoMicrordquo external audible alarm 42
Illuminated warning signs 43
ldquoImpulsrdquo external display unit 43
UIM-3D area monitor count rate meter 44
DKG-05D personal gamma dosimeter 46
DVS-02D gamma-neutron personal electronic dosimeter 47
DVGI-8D new pen-type personal ionization chamber dosimeters 48
DKG-02U ldquoARBITERrdquo wide range gamma-dosimeter 49
DKG-07D ldquoDROZDrdquo gamma-dosimeter 50
MKS-15D ldquoSNEGIRrdquo multi ndash purpose radiation survey meter 51
SRPS-05D gamma monitor 52
DOZA-TLD multipurpose TLD system 53
DKS-96 universal radiation survey meter 54
EXTERNAL PROBES ALPHA
Alpha BDZA-96 55
Alpha BDZA-96B 55
Alpha BDZA-96M 55
Alpha BDZA-96S 55
Alpha BDZA-96T 55
EXTERNAL PROBES BETA
Beta BDZB-96 56
Beta BDZB-99 56
Beta BDZB-96B 56
Beta BDZB-96S 56
EXTERNAL PROBES GAMMA
Gamma BDKS-96B 57
Gamma and beta BDKS-96S 57
Gamma BDMG-96 57
EXTERNAL PROBES GAMMA
Gamma-search BDVG-96 58
Gamma-search BDPG-96 58
ContentsRadiation monitoring systemldquoPELIKANrdquo Radiation monitoring system (RMS) 6
BDMG-101 high range gamma area monitor 10
DBG-S11D wide range gamma area monitor 11
BDRG-52 high range gamma area monitor for accident and post-accident conditions 12
UDGP-01 Liquid technological environments monitor 13
UDMN-100 neutron area monitor 14
UDKG-100 Wel Liquid gamma monitor 14
BOP-1M data processing and transmission unit 15
UDA-1AB particulate monitor 16
UDG-1B noble gas monitor 17
UDG-03D noble gas monitor 18
UDI-1B iodine monitor 19
UDGB-01 noble gasesH-3C-14 monitor 20
UDGP-01 steam generator leakage monitor 21
UPPVM air flow parameters monitor 22
ldquoIMPULSrdquo external display unit 23
BI-2 remote display amp alarm unit 24
BASBAS-1s external alarm 25
SKGAV stack monitor 26
RMS software 28
RMS workstation ndash operator console 29
Configurator software 29
RM RACK radiation monitoring rack 30
SRKS-01D criticality accident alarm system 32
ldquoATLANT-Mrdquo environmental radiation monitoring system 34
ldquoBREEZErdquo high-volume air sampler 35
ldquoGAMMA-SENSORrdquo gamma-survey system 36
Radiation monitoring equipmentAREA MONITOR ldquoFREGATrdquo 38
BPI-1D local display unit 39
80
Gamma-search BDPG-96M 58
Gamma BDKG-96 stainless steel casing for geologic applications well logging 59
EXTERNAL PROBES NEUTRON
Neutron BDMN-96 59
Neutron-search BDKN-96 59
RZB-05D Hand-foot-clothing monitor 60
RZBA-04-04M whole body contamination monitor 61
RZA-05D alpha hand-monitor 62
UMF-2000 low level alpha- beta- counter 63
DRK dose area product meter 64
ldquoPROGRESS-BETArdquo scintillation beta spectrometer 65
ldquoPROGRESS-GAMMArdquo scintillation gamma spectrometer 66
ldquoPROGRESS-G(P)rdquo portable scintillation gamma spectrometer 67
ldquoPROGRESS-ARrdquo alpha radiometer 68
ldquoPROGRESSrdquo whole body counter 69
MKG-01D ldquoSADOVNIKrdquo spectrometry system 70
MKS-01A ldquoMULTIRAD-ASrdquo alpha spectrometer 71
UCRV-2 airflow monitor 72
PVP-06 portable air sampler 73
ldquoALPHARAD PLUSrdquo radon thoron amp their progeny monitor 74
UPG-P desktop gamma beam irradiator 75
UPGD-2M-D gamma beam irradiator 76
UKPN-2M-D neutron beam irradiator 77
Radiation monitoring system SPC ldquoDozardquo
2726
Electrical characteristicsbull Power supply 220 V 50 Hz bull Interfaces RS-232 RS-485 Ethernetbull programmable relay output (SPDT relay)
Alarmbull Sound alarm 80 divide 100 dBA at distance 1 mbull Visual alarm green yellow redbull Connection of the external alarm unit ldquoBASrdquo type
Related monitors and equipmentsbull UDA-1AB particulate monitorbull UDG-1B noble gas monitorbull UDI-1B iodine monitorbull UPPVM air flow parameters monitorbull Sampling and sample separation rack
Air flow parameters monitor rack
Reference standards Nuclear IEC 60761 IEC 61171 IEC 61172 IEC 62302 ISO 2889 EMC IEC 61010 IEC 61000-6-2 Seismic IEC 60980
Sampling and sample separation rack
Continuous monitoring of radioactivity in gaseous effluentsbull Automatic monitoring of the alpha- and beta-
radioactive aerosol noble gas and radioiodine concentrations in the air in ventilation ducts and stacks
bull Monitoring of the flow rate temperature and humidity of the gas flow
bull Separation of gaseous effluent into targeted fractions by means of a two-stage filter
bull Reversion of gas after analysis to the ventilation system
Physical characteristics
Particulate (UDA-1AB)bull Silicon specrometric detectors (2 pcs for measure-
ment and for gamma-background compensation) bull Filter tape types LFAS FSLWbull Tape consumption (when continuous operation)
10 m50 days
Measurement range bull Alpha 10-2 divide 2105 Bqm3 bull Beta 10-1 divide 106 Bqm3
Energy range bull Alpha 30 divide 90 MeV bull Beta 005 divide 30 MeV
Noble gas (UDG-1B)bull silicon detectors (2 pcs for measurement and for
gamma-background compensation)
Measurement range bull 104 divide 6109 Bqm3
Energy range bull 008 divide 30 MeV
Iodine (UDI-1B)bull scintillation detectors CsI(Tl) (2 pcs for measure-
ment and for background compensation)
SKGAV STACK MONITOR
Particulate noble gas and iodine monitors rack
Measurement range bull 37 divide 37105 Bqm3
Energy range bull 015 divide 30 MeV
Air flow parameters (UPPVM)Measurement range bull air flow velocity 1 divide 20 msbull air temperature 0 divide +80 ordmСbull air humidity 10 divide 95
Radiation monitoring system SPC ldquoDozardquo
28 29
CONFIGURATOR SOFTWAREMaintenance and set-up softwarebull Set-up and verify RMS monitorsbull Control testing adjustment and repair of RMS
monitorsbull Monitors measurement results archive receive
and View bull Communication through RS-232
RMS WORKSTATION ndash OPERATOR CONSOLEOrganization of interaction of the RMS Server and Monitors
Single monitor console includes vandal-proof key-board amp UPS
Reference standard IEC 61559-1 IEC 61559-2
RMS SOFTWAREData acquisition storing and visual representation RMS monitors measurement resultsbull Ethernet IEEE 8023 networkbull Clientserver architecturebull TCPIP protocolbull Oracle based Data Basebull Supremal by means InSat MasterSCADA
Radiation monitoring system SPC ldquoDozardquo
30 31
Delivery setComposition and modification depend on the tasks to be solved using the RM Rack
The rack which is an integral part of RM Rack accommodatesbull Monitors UDA-1AB UDG-1B UDG-03D UDI-1B
UDGB-01Tbull DBG-S11D Wide range gamma area monitor
BDMG-101 High range gamma area monitor UDMN-100 Neutron area monitor BDRG-52R High range gamma area monitor
bull BI-2 Remote display amp alarm unitbull Pump unit BN-01bull Data processing and transmission unit BOP-1Mbull External alarm BAS or BAS-1sbull Equipment of sampling line (flow meters ball
valves filter holder piping solenoid valve)bull Switchboard (intended for switching of all equip-
ment and transfer of data to the upper level via the unified communication channel)
RM RACK RADIATION MONITORING RACK
The radiation monitoring rack (RM Rack) is designed for continuous monitoring of radiation parameters in premises and technological systems at nuclear facil-ities RM Rack can be used as a structural element of the lower-level of RMS at nuclear power plants and other nuclear facilities that involved in obtaining processing use and storage of radioactive materials
FeaturesContinuous automatic monitoring of the alpha- and beta- radioactive aerosol beta-emitting radioactive gases and radioiodine concentrations in the working air and in the air in stacks and others radiation parameters in the facilities
The stand providesbull Primary processing storage and transmission of
measured and related data into the information channel based on the Ethernet IEEE 8023 inter-face (TCPIP protocol)
bull Transfer of required data to the location where the equipment is installed via technological channels based on RS-232 interface
bull Generation of audible and visual warning alarm signals when the preset thresholds are exceeded
bull Display of received data on the LCD
Radiation monitoring system SPC ldquoDozardquo
32 33Reference standards IEC 60860 ANSIANS-83 ISO 7753
Purposebull Detection and recording of criticality accident
(CA) by measuring the absorbed dose rate of gamma-neutron radiation in the premises of monitored object its comparison with a threshold value and generation of audible and visual signals
bull Automatic collection processing storage and display of measurement data and related infor-mation as visual and graphical representation for operators of nuclear safety service
Functions of the systembull Detection and recording of CA events by con-
tinuous measurement of absorbed dose rate of gamma radiation comparison of measured values with preset thresholds generation of signals to activate the alarm
bull Activation of audible visual alarmbull In the event of CA turning on warning signals
ldquoDO NOT ENTERrdquo at illuminated information pan-els placed at the entrances to the controlled area
Featuresbull Data can be transferred to external data commu-
nication channel using RS-485 interface (DiBus data exchange protocol)
bull Automatic self-testing of detection units BR-04D with display of information about the type of fault
bull Possibility for connecting additional a detection and alarm units
bull Ability to function in general regardless of the functioning of components within the agreed scope of nuclear safety tasks
bull Radiation hardness up to 100 Gy
SRKS-01DCRITICALITY ACCIDENT ALARM SYSTEM
Features of softwarebull Collection of information via RS-485 network
displaying it on the PC monitor transmission to remote users archiving and storage
bull Status monitoring and display of values measured by BR-04D and DBG-S11D in locations as per layout of premises
bull Access to archived data with possibility to gener-ate reports for periods determined by operator
bull Maintenance and archiving of a log of dosimetric measurements data and events along with their time stamps
bull Possibility to transfer data to external users via Ethernet network for integrating of CA into higher level systems
Basic complete setLower level bull Control unit with power supplybull BR-04D detection unitsbull BZS-01D audible alarm unitsbull BSS-01D visual alarm unitsbull SIT-01D illuminated warning signsbull PBZ panels for muting audible alarmbull Network communication module
Additional lower layer devicesbull DBG-S11D wide range gamma area monitor
Upper layer bull CDP central display panelbull Service workstation
RS-485
RS-485
RS-4
85
Audible alarm units BZS-01D
Illuminated warning signs SIT-01D
Detection units BR-04D
Network communication
moduleDBG-S11D wide range gamma area monitor
Panels for muting audible alarm
Control unit with power supply
Visual alarm units BSS-01D
RS-485
RS-485
RS-4
85
Audible alarm units BZS-01D
Illuminated warning signs SIT-01D
Detection units BR-04D
Network communication
moduleDBG-S11D wide range gamma area monitor
Panels for muting audible alarm
Control unit with pow-er supply
Visual alarm units BSS-01D
RS-485
RS-4
85
Audible alarm units BZS-01D
Illuminated warning signs SIT-01D
Detection units BR-04D
Network communication
moduleDBG-S11D wide range gamma area monitor
Panels for muting audible alarm
Control unit with power supply
Visual alarm units BSS-01D
RS-485
RS-485
RS-4
85
Audible alarm units BZS-01D
Illuminated warning signs SIT-01D
Detection units BR-04D
Network communication
moduleDBG-S11D wide range gamma area monitor
Panels for muting audible alarm
Control unit with power supply
Visual alarm units BSS-01D
Ethernet
Central display panel Service workstation
RS-485
RS-485
RS-4
85
BZS-01D audible alarm units
SIT-01D illuminated warning signs
BR-04D detection units
Network communication
moduleDBG-S11D wide range gamma area monitor
PBZ panels for muting audible alarm
Control unit with power supply
BSS-01D visual alarm units
Radiation monitoring system SPC ldquoDozardquo
34 35
ldquoBREEZErdquoHIGH-VOLUME AIR SAMPLER
Physical characteristicsbull Measurement range of air flow rate
250 divide 1200 m3hbull Continuous operation time not less than 24 h
Filter materialsbull High-purity glass fiberbull Pure quartz or cellulosebull Filter fabric FPP-15-15
Electrical characteristicsPower supply bull 220380 V 50 Hz
Interfaces bull RS-485bull Ethernetbull GSMGPRS (option)
Environmental characteristicsTemperature range bull minus 40 divide + 40 ordmC
Relative humidity limit at 35 ordmC bull 95
Atmospheric pressure range bull 840 divide 1067 kPa
Versionsbull Standalone unit bull Part of Environmental Radiation Monitoring
System (ERMS)
Type of detection unitsbull Beta block BDZB-100Lbull DBG-S11D wide range gamma area monitorbull Scintillation spectrometric block
The motor of Air Sampler is controlled by an electronic flow sensor that detects changes in the operators pre-set flow rate caused by changes in temperature barometric pressure and pressure drop due to dust loading on filter media It compensates for these changes by adjusting the motor speed to maintain the pre-set flow ratebull Measurement of parameters of ionizing radiation bull Standalone mode of operation or as the part
of Environmental Radiation Monitoring System (ERMS)
Purposebull Environmental Radiation Monitoring System
(ERMS) in the control and buffer areas of the radia-tion and nuclear facilities
Referencesbull Since the year 2000 the system is successfully
operating the ERMSs at 8 Russian nuclear power plants (about 180 monitoring stations)
bull Since the year 2005 the ERMS is operating in the Moscow (about 40 monitoring stations)
bull Since the year 2005 the regional ERMS is under operation in several Russian Federation regions
Basic complete setMonitoring stations bull Data processing and transmission unit BOP-1TA bull Gamma area monitor DBG-S11D
Central data processing station (CDPS)bull Data processing and transmission unit BOP-1TAbull Server
By requestbull Emergency Response and Crisis Management
Centers for enterprisesbull Regional Emergency Response and Crisis Manage-
ment Centersbull rdquoBreezerdquo High-Volume Air Samplerbull Mobile lab with gamma-survey system rdquoGammandash
sensorrdquo
ldquoATLANT-MrdquoENVIRONMENTAL RADIATION MONITORING SYSTEM
Monitoring system for the continuous radiation monitoring of territories and facilities with the data transmission GSMGPRS network
Data transmission bull GSMGPRS
Power supply bull 220 V 50 Hz
Continuous autonomous operation (at 20 ordmC)bull From built-in battery not less than 5 hoursbull From external battery not less than 24 hours
Operation temperature bull Minus 40 divide +50 ordmC
Operation humidity bull Up to 98
Protection bull IP65
Reference standards Nuclear IEC 61017-11991 IEC 61017-21994
36
Radiation Monitoring Equipment
bull Localization of radioactive contaminationsbull Database with dose rate contaminations
spectra measurement date amp time coordi-nates
bull Work as part of mobile laboratory or as part of Environmental Radiation Monitoring System with real-time data transfer
Physical characteristicsDetector bull Scintillation NaI (Tl) GM counters
Measurement rangebull 01 ndash 107 μSvh
Energy range bull 005 ndash 3 MeV
Operation temperature range bull minus 10 divide +50 ordmС
Electrical characteristics bull Power supply 220 V 50 Hz
ldquoGAMMAndashSENSORrdquoGAMMA-SURVEY SYSTEM
SPC ldquoDozardquoRadiation monitoring equipment
38 39
AREA MONITOR ldquoFREGATrdquoArea Monitor ldquoFregatrdquo is designed for building rela-tively simple and inexpensive radiation monitoring systems at such facilities as radionuclide sources storage areas isotope products warehouses nuclear medicine departments PET centers calibration laboratories where sources of ionizing radiation are used etc
Small scale automated radiation monitoring systems built with ldquoFregatrdquo components featuring audible and visual alarms are matched suitable to meet the regulatory radiation safety requirements
Area monitor ldquoFregatrdquo requires virtually no adjust-ment it is simple and convenient for installation and operation
BPI-1D LOCAL DISPLAY UNIT
Display of monitored parameters values received from external measuring devices
Purposebull Processing and display of values of monitored
parameters on information panel bull Comparison of values of monitored parameters
with thresholdsbull Transfer of monitored parametersrsquo values to
networkbull Generation of alarm in case of exceeding of preset
thresholds including external alarm devices
FeaturesTesting the unit and connected devicesbull Visually on the panelbull Using adjustment software when connected to
PC via USB
Automatic self-testing
The panel displays the following informationbull Diagnostic information about the status of con-
nected devicesbull Current date and timebull Values of measured parametersbull Position of measured values with respect to the
thresholds in the form of scales with green yellow and red zones
bull Time history (trend) for each measured value
Physical characteristicsTemperature range bull minus 10 divide + 50 ordmC
Maximum number of connected devicesbull measuring devices 15bull external audible and visual alarm 15
Display diagonal bull 152 cm (6)
Electrical characteristicsbull Interfaces RS-485bull Power supply 220 V 50 Hz 12 divide 24 V
Mechanical characteristicsbull Protection index IP54bull Paint decontaminable
Overall dimensions weightbull 296x248x118 mm 5 kg
DBG-S11D wide range gamma area monitor
UDMN-100 neutron area monitor
Ethernet RS-485
UDKS-100 gamma and X-ray area monitor
BPI-1D Local display unit
BAS-2 ldquoMicrordquo external visual alarm
BZS-2 ldquoMicrordquo external audible alarm
ldquoImpulsrdquo external display unit
Service workstation
Illuminated warning signs
SPC ldquoDozardquoRadiation monitoring equipment
4140
Continuous automatic monitoring of the gamma- X-ray ambient dose equivalent rate
Physical characteristicsbull Detector tissue-equivalent plastic scintillator
Oslash 45times20 mm
Measurement range bull Dose rate measurement range 01 μSvh divide 1 Svh bull Energy range 0015 divide 10 MeV
Mechanical characteristicsbull Protection index IP65bull Paint decontaminable
Overall dimensions weightbull Oslash72times265 mm 15 kg
UDKS-100 GAMMA AND X-RAY AREA MONITOR
UDMN-100 NEUTRON AREA MONITOR
Physical characteristicsbull detector ndash scintillator ZnS(Ag) Li-6
Measurement range bull 01 μSvh divide 01 Svh
Energy range bull 0025 eV divide 100 MeV
Temperature range bull minus 45 divide +50 ordmC
Electrical characteristicsbull Interfaces RS-485
Mechanical characteristicsbull Protection index IP 65bull Paint decontaminable
Overall dimensions weight bull 428times258times347 mm 115 kg
Continuous automatic monitoring of the neutron-radiations ambient dose equivalent ratebull Spherical polyethylene moderator Oslash 239 mm
MEASURING UNITS
DBG-S11D WIDE RANGE GAMMA AREA MONITOR
Continuous automatic monitoring of the gamma- ambient dose equivalent rate
Physical characteristicsbull Detector ndash GM counters
Measurement rangebull DBG-S11D 01 μSvh divide 10 mSvhbull DBG-S11D-01 01 μSvh divide 10 Svhbull DBG-S11D-02 01 μSvh divide 100 Svh
Energy rangebull 005 divide 30 MeV
Temperature range bull minus 40 divide +50 ordmC
Electrical characteristicsbull Interfaces RS-485 USB
Mechanical characteristicsbull Protection index IP 68bull Paint decontaminable
Overall dimensions weightbull DBG-S11D Oslash 68times141 mm 065 kg bull DBG-S11D-01 Oslash 68times179 mm 07 kgbull DBG-S11D-02 Oslash 68times179 mm 07 kg
Versionsbull DBG-S11Dbull DBG-S11D-01bull DBG-S11D-02
Reference standards Nuclear IEC 60846 IEC 60532 EMC IEC 61010 IEC 61000-6-2 Seismic IEC 60980
SPC ldquoDozardquoRadiation monitoring equipment
4342
ALARM UNITS
Generation visual signals of the excess of preset thresholds
Physical characteristicsLength of communication cablebull up to 1200 mbull Alarm Visual alarm green yellow red
Electrical characteristicsbull Power supply +12 V
Mechanical characteristicsbull Protection index IP 23
Overall dimensions weight 160times84times41 mm 02 kg
BAS-2 ldquoMICROrdquo EXTERNAL VISUAL ALARM
Generation audible signals of the excess of preset thresholds
Physical characteristicsLength of communication cablebull up to 1200 mbull Audible alarm 80 divide 100 dB at a distance of 1 m
Electrical characteristicsbull Power supply +12 V
Mechanical characteristicsbull Protection index IP 23
Overall dimensions weight 160times84times41 mm 02 kg
BZS-2 ldquoMICROrdquo EXTERNAL AUDIBLE ALARM
Physical characteristicsLength of communication cablebull up to 1200 m
Electrical characteristicsbull Power supply 220 V 50 Hz
Mechanical characteristicsbull Protection index IP 23
Overall dimensions weight bull 330times110times20 mm 05 kg
Physical characteristicsLength of communication cablebull up to 1200 m
Character height bull ldquoImpuls-910-Rrdquo 100 mmbull ldquoImpuls-915-D4Srdquo 150 mmbull ldquoImpuls-927-D4Srdquo 270 mm
Operating temperature rangebull ldquoImpuls-910-Rrdquo 0 divide +50 degCbull ldquoImpuls-915-D4Srdquo ldquo-727-D4Srdquo minus 40 divide +50 degC
Electrical characteristicsbull Power supply 220 V 50 Hz
Mechanical characteristicsProtection index bull ldquoImpuls-910-R IP 44bull ldquoImpuls-915-D4Srdquo ldquo-727-D4Srdquo IP 65
Overall dimensions weight bull ldquoImpuls-910-Rrdquo 400times160times60 mm 3 kgbull ldquoImpuls-915-D4Srdquo 815times250times80 mm 5 kgbull ldquoImpuls-927-D4Srdquo 1250times330times80 mm 5 kg
ILLUMINATED WARNING SIGNS
ldquoIMPULSrdquo EXTERNAL DISPLAY UNIT
SPC ldquoDozardquoRadiation monitoring equipment
4544
Individual threshold setting for each measurement channel
Continuous area and process monitoring
Collect amp display data from two measurement chan-nels (units with RS-485 or analog pulses)
Audible and visual alarms on exceeding preset thresholds or status of connected devices
Individual threshold setting for each measurement channel
Switching on the external alarm or executive devices when any threshold is exceeded
The wide panel displays the following information bull Values of measured parameters as min-1∙cm-2
s-1∙cm-2 μSvhbull Diagnostic information about the status of con-
nected devicesbull Current date and timebull Position of measured values with respect to the
thresholds in the form of scales with green yellow and red zones
bull Time history (trend) for each measured value
Physical characteristics Measurement range bull Count rate up to 107 CPM (170 kHz)
Operating temperature range bull minus 20 divide +50 ordmC
Electrical characteristics bull Power supply 220 V bull Interfaces USB
Mechanical characteristics bull Protection index IP 65 bull Overall dimensions weight 222times164times73 mm
40 kg
UIM-3D AREA MONITOR COUNT RATE METER
Measurement of alpha radiation flux density
Detector unit BDZA-100 (70 cm2) Measurement range 01 divide 104 min-1∙cm-2
Detector unit BDZA-100B (300 cm2) Measurement range 01 divide 2103 min-1∙cm-2
Measurement of beta radiation flux density
Detector unit BDZB-100 (28 cm2) Measurement range 10 divide 105 min-1∙cm-2
Detector unit BDZB-100L (30 cm2) Measurement range 10 divide 104 min-1∙cm-2
Detector unit BDZB-11D (84 cm2) Measurement range 5 divide 15∙104 min-1∙m-2
OPTIONAL PROBESMeasurement of gamma radiation flux density
Detector units BDEG-03 Measurement range 4 divide 2000 s-1∙cm-2
Detector unit UDKG-100 for operation in the rocks ore liquid media and sludge Measurement range 40 divide 8000 s-1∙cm-2
Measurement of the ambient dose equivalent rate
Detector unit DBG-S11D Measurement range 01 μSvh divide 100 Svh
Measurement of neutron radiation ambient dose equivalent rate
Detector unit BDMN-100 Measurement range 01 μSvh divide 01 Svh
SPC ldquoDozardquoRadiation monitoring equipment
46 47Reference standards Nuclear IEC 61526
Measurement of gamma-radiation personal dose equivalent Hp(10)bull Stand-alone dosimeter or composed of dosimetric
system onebull Audible and visual alarmbull Large memory dose accumulation historiesbull Exclusion of unauthorized intervention in dosim-
etry operation
DKG-05D PERSONAL GAMMA DOSIMETER
Physical characteristicsDetectors bull Silicon
Measurement range bull Dose rate 1 μSvh divide 10 Svhbull Dose 01 μSv divide 15 Sv
Energy range bull 005 divide 30 MeV
Electrical characteristicsbull Power supply rechargeable NiMH battery 1
alcaline battery (type AAA)
Operation timebull Till recharging not less 400 hoursbull With one set batteries not less 1000 hours
Mechanical characteristicsOverall dimensions weight bull 47times26times87 mm (with clip) 70 g
Environmental characteristicsbull IP65bull Temperature range minus 20 divide +45 ordmCbull Humidity up to 98 at 35 ordmCbull Shock vibration and drop resistant
Alarmbull Excess of alarm thresholdsbull Warnings of self-test failure and battery discharge bull Audible alarm 80 dB at 40 cmbull Visual alarm blinking LED
Relative equipmentbull One dosimeter charger ZU-1Mbull Chargestorage cassetes KZU-28KZU-56bull ldquoSmart chargingrdquo feature extends battery life timebull DKG-05D reader US-05bull DKG-05D system reader DVS-01D
Reader-PC interfacebull US-05 USB bull DVS-01D Ethernet
KZU-28
Physical characteristicsDetectors bull Silicon Li-6
Gamma measurement range bull Dose rate 1 μSvh divide 10 Svhbull Dose 01 μSv divide 15 Sv
Gamma energy range bull 005 divide 60 MeV
Neutron measurement range bull Dose rate 1 μSvh divide 2 Svhbull Dose 20 μSv divide 15 Sv
Neutron energy range bull 0025 eV divide 20 MeV
Electrical characteristicsPower supply bull Rechargeable NiMH batterybull Operatiion time till recharging not less 200 hours
Mechanical characteristicsOverall dimensions weight bull 47times26times87 mm (with clip) 70 g
Environmental characteristicsbull IP65bull Temperature range minus 20 divide +40 ordmCbull Humidity up to 75 at 30 ordmCbull Shock vibration and drop resistant
Alarmbull Excess of alarm thresholds bull Warnings of self-test failure and battery discharge bull Audible alarm 80 dB at 40 cmbull Visual alarm blinking LED
Relative equipmentbull One dosimeter charger ZU-1Mbull Chargestorage cassetes KZU-28 KZU-56bull ldquoSmart chargingrdquo feature extends battery life timebull DVS-02D reader UZS-01Sbull DVS-02D system reader DVS-01D
Reader-PC interfacebull UZS-01S USB bull DVS-01D Ethernet
UZS-01DReference standards Nuclear IEC 61526
DVS-02D GAMMA-NEUTRON PERSONAL ELECTRONIC DOSIMETER
Measurement of gamma- and neutron radiations personal dose equivalent Hp(10)bull Stand-alone dosimeter or composed of dosimetric
system onebull Audible and visual alarmbull Large memory dose accumulation historiesbull Exclusion of unauthorized intervention in dosim-
etry operationbull Both albedo thermal neutrons and intermediate
fast neutrons registrationbull Usable in the fields of Pu(Be) Po(Be) Cf and other
neutron sources as well as near nuclear reactors without neutron spectrum estimation
SPC ldquoDozardquoRadiation monitoring equipment
48 49
Dosimeters DVG-03D
DVGI-8D NEW PEN-TYPE PERSONAL IONIZATION CHAMBER DOSIMETERS
Measurement of personal dose equivalent Hp(10) of gamma and X-ray radiationbull Hp(10) of continuous and pulsed gamma and
X-ray radiation bull Electronic reader KSU-1bull Dosimeter DVG-03D with electronic ID bull Personal dose histories in the readerrsquos memorybull Readerrsquos connection with PC for database main-
tenance
Physical characteristicsDetector bull Ionization chamber
Measurement range bull 001 mSv divide 25 mSv
Energy range bull 0015 divide 25 MeV
Temperature range bull Reader KSU-1 +10 divide +50 ordmСbull Dosimeter DVG-03D minus 40 divide +50 ordmС
Electrical characteristicsPower supply bull Reader KSU-1 220 V 50 Hz built-in batteries bull Dosimeter DVG-03D four batteries CR 1025 bull Batteries life 3 yearsbull Readers interfaces RS-232USB 20
Mechanical characteristicsOverall dimensions weightbull Dosimeter DVG-03D Oslash 18times126 mm 005 kgbull Reader KSU-1 235times232times125 mm 28 kg
Reference standards Nuclear IEC 62387-1
DKG-02U ldquoARBITERrdquo WIDE RANGE GAMMA-DOSIMETER
Physical characteristicsDetectors bull GM counters
Measurement rangebull Dose-rate 01 μSvh divide 3 Svhbull Dose 1 μSv divide 100 Sv
Energy range bull 005 divide 3 MeV
Electrical characteristicsbull Power supply 2 alcaline batteries (type AA)bull Batteries life not less 200 hours
Mechanical characteristicsOverall dimensions weight bull 152times82times32 mm 03 kg
Environmental characteristicsbull Temperature range minus 20 divide +50 ordmCbull Humidity up to 90 at +25 ordmCbull Shock vibration and drop resistant
Reference standards Nuclear IEC 60846
Measurement of gamma radiation ambient equiva-lent dose H(10) and dose rate H(10)bull Audible signals (clicks) for radiation condition
estimationbull Analog scale for search modebull Audible and visual alarms of the excess of preset
dose and dose rate thresholds bull Shock-resistant water-proof easy decontamina-
tion casebull 100 measurement results memory with date and
time of measurementbull Indication of total dose accumulated during
exploitation time bull Indication of measurement result statistical
uncertainty
SPC ldquoDozardquoRadiation monitoring equipment
50 51
Physical characteristicsDetectors bull GM counter
Measurement rangebull Dose-rate 01 μSvh divide 3 mSvhbull Dose 1 μSv divide 02 Sv
Energy range bull 005 divide 3 MeV
Temperature range bull Minus 20 divide +50 ordmC
Electrical characteristicsbull Power supply 2 alcaline batteries 15 V (type AA)bull Batteries life not less 200 hours
Mechanical characteristicsOverall dimensions weight bull 122times74times29 mm 025 kg
Reference standards Nuclear IEC 60846
DKG-07D ldquoDROZDrdquoGAMMA-DOSIMETER
Measurement of gamma radiation ambient equiva-lent dose H(10) and dose rate H(10)bull Two independent measurement channels dose
and dose ratebull Audible signals (clicks) for radiation condition
estimationbull Continuous measurement with updating meas-
urement resultbull Measurement result can be obtained with any
desired statistical uncertainty (error)bull Automatic restart when radiation level sharply
changesbull Indication of statistical uncertainty (error) during
measurement process
Continuous measurement with updating measure-ment result
Automatic restart when radiation level sharply changes bull Gamma dose H(10) and dose-rate H(10) meas-
urementbull Beta and gamma contamination surveybull Indication of statistical uncertainty during the
measurementbull Continuous measurement with accuracy increas-
ing with time bull Automatic restart triggered by change of gamma
dose-ratebull Compensation of gamma count rate while meas-
uring beta radiationbull Indication of battery charge levelbull Audible signal of the excess of preset threshold
Physical characteristicsDetectors bull GM counter
Measurement range bull Dose-rate 01 microSvh divide 20 mSvhbull Dose 1 microSv divide 100 Svbull Beta flux density (for Sr-90+Y-90)
10 divide 105 cm-2 min-1
Energy range bull Gamma 005 divide 3 MeVbull Beta 01 divide 3 MeV
Temperature range bull Minus 20 divide +50 ordmC
MKS-15D ldquoSnegirrdquo backside
MKS-15D ldquoSNEGIRrdquoMULTI ndash PURPOSE RADIATION SURVEY METER
Reference standards Nuclear IEC 60846 IEC 60325
Electrical characteristicsbull Power supply 2 alcaline batteries (type AA)bull Battery life not less 400 hours
Mechanical characteristicsOverall dimensions weight bull 124times72times35 mm 035 kg
SPC ldquoDozardquoRadiation monitoring equipment
52 53
Physical characteristicsDetectorbull GM counter
Measurement range bull 01 μSvh divide 20 mSvh
Energy range bull 005 divide 30 MeV
Threshold setting range bull 03 μSvh divide 20 mSvh
Step change of the thresholdbull In the range 03 divide 10 μSvh with the step
001 μSvhbull In the range 10 divide 100 μSvh with the step
01 μSvhbull In the range 100 divide 2000 μSvh with the step
10 μSvh
Electrical characteristicsPower supply bull 220 V 50 Hz bull Relay output
Mechanical characteristicsProtection index bull IP 40
Overall dimensions weight bull 226times120times75 mm 07 kg
Alarmbull Sound alarm 80 divide 100 dBA at distance 1 mbull Visual alarm redbull Connection of the external alarm signaling unit
Reference standards Nuclear IEC 60846 IEC 60532
Continuous automatic monitoring of the ambient dose equivalent rate bull Measurement of gamma dose rate H(10)bull Audible and visual alarm signals for preset
thresholdsbull Switching on the external signaling or executive
devices
SRPS-05D GAMMA MONITOR
Measurement ofbull Gamma and X-ray personal dose equivalent
Hp(10)bull Neutron personal dose equivalent Hp(10)bull Lens dose equivalent Hp(3)bull Skin dose equivalent Hp(007)bull TLD reader day-to-day tests using built-in LEDbull No needs nitrogen for heating
Physical charachteristicsDetectors bull 7LiF Mg Ti (gamma beta)bull 6LiF Mg Ti (neutron)
Gamma and X-ray Hp(10) Measurement range bull 500 μSv divide 10 Sv
Energy range bull 0015 divide 30 MeV
Neutron Hp(10)Measurement range bull 01 mSv divide 100 mSv
Energy range bull 0025 eV divide 10 MeV
Beta and photons Hp(007) Hp(3) Measurement range bull 2 mSv divide 100 Sv
Energy range bull Beta 025 divide 35 MeVbull Photons lt15 keV
Mechanical characteristicsDosimeters overall dimensions weight bull Gamma Hp(10) DTL-2 holder - 62times26times16 mm
16 gbull DTU holder - 42times28times18 mm 8 gbull Lens Hp(3) face skin Hp(007) Oslash 32times16 mm 9 gbull Finger skin Hp(007) 90times20times2 mm 1 gbull Neutron gamma Hp(10) 48times40times20 mm 30 g
Reference standards Nuclear IEC 61066
DTL-2 DTU-2
MKD (A-type) DVNG-M
DOZA-TLD MULTIPURPOSE TLD SYSTEM
SPC ldquoDozardquoRadiation monitoring equipment
54 55
Continuous and pulsed gamma and X-ray dose H(10) and dose-rate measurementbull Alpha beta and gamma contamination surveybull Neutron dose H(10) and dose-rate measurementbull Gamma radiation flux density in boreholes and
liquid media measurement
Electrical characteristicsPower supply bull UIK-05 four C-size batteriesbull UIK-05-01 rechargeable batterybull UIK-06 rechargeable battery
Interfaces bull RS-232bull USB (via adapter)
bull Detector type automatic determination and corre-sponding measurement modes selection
bull Alarm threshold settings ndash for dose dose-rate alpha and beta contaminations
bull ldquoDetectrdquo and ldquoLocaterdquo modes for survey probes
Reference standards Nuclear IEC 60846 IEC 60325 IEC 61005 IEC 62363
Case
UIK-06 control unit165times78times48 mm 03 kg
DKS-96UNIVERSAL RADIATION SURVEY METER
UIK-05 control unit202times86times90 mm 10 kg
BDZA-96
BDZA-96B
BDZA-96M
BDZA-96S
BDZA-96T
EXTERNAL PROBES ALPHAALPHA BDZA-96Detector bull ZnS(Ag) 70 cm2
Measurement range (for Pu-239)bull 01 divide 104 min-1cm-2
Overall dimensions weightbull Oslash 130times240 mm 11 kg
ALPHA BDZA-96BDetector bull ZnS(Ag) 300 сm2
Measurement range (for Pu-239)bull 01 divide 2103 min-1cm-2
Overall dimensions weightbull Oslash 230times290 mm 40 kg
ALPHA BDZA-96MDetector bull ZnS(Ag) 10 сm2
Measurement range (for Pu-239)bull 01 divide 105 min-1cm-2
Overall dimensions weightbull Oslash 65times240 mm 09 kg
ALPHA BDZA-96SDetector bull ZnS(Ag) 30 сm2
Measurement range (for Pu-239)bull 01 divide 5104 min-1cm-2
Overall dimensions weightbull Oslash 90times240 mm 10 kg
ALPHA BDZA-96TDetector bull Silicon 5 сm2
Measurement range (for Pu-239)bull 01 divide 106 min-1cm-2
Overall dimensions weightbull Oslash 50times60 mm 015 kg
SPC ldquoDozardquoRadiation monitoring equipment
56 57
BETA BDZB-96Detector Scintillator 28 сm2
Measurement range (for Sr-90+Y-90)bull 10 divide 105 min-1cm-2
Energy rangebull 03 divide 30 MeV
Overall dimensions weightbull Oslash 90times230 mm 09 kg
BETA BDZB-99Detector bull GM counter 30 сm2
Measurement range (for Sr-90+Y-90)bull 20 divide 104 min-1см-2
Energy rangebull 012 divide 30 MeV
Overall dimensions weightbull Oslash 88times80 mm 04 kgbull Telescopic pole length 07 m
BETA BDZB-96BDetector bull GM counter 80 сm2
Measurement range (for Sr-90+Y-90)bull 3 divide 104 min-1сm-2
Energy rangebull 012 divide 30 MeV
Overall dimensions weightbull 150times200times110 mm 15 kg
BETA BDZB-96Sbull Detector GM counter 15 сm2
Measurement range (for Sr-90+Y-90)bull 10 divide 3104 min-1cm-2
Energy rangebull 012 divide 30 MeV
Overall dimensions weightbull Oslash 65times65 mm 03 kgbull Telescopic pole length 07 m
BDZB-96
BDZB-99
BDZB-96B
BDZB-96S
EXTERNAL PROBES BETA
GAMMA BDKS-96BDetector bull Tissue-equivalent scintillator Oslash 45times20 mm
Measurement rangebull Dose rate H(10) 01 μSvh divide 1 Svhbull Dose H(10) 01 μSv divide 10 Sv
Energy rangebull 0015 divide 10 MeV
Overall dimensions weightbull Oslash 60times250 mm 085 kg
GAMMA AND BETA BDKS-96SDetector bull Double GM counters
Measurement rangebull Gamma dose rate H(10) 01 μSvh divide 1 mSvhbull Gamma dose H(10) 01 μSv divide 10 Svbull Beta 10 divide 3104 min-1cm-2
Energy rangebull Gamma 005 divide 3 MeVbull Beta 012 divide 3 MeV
Overall dimensions weightbull Oslash 80times80 mm 035 kgbull Telescopic pole length 07 m
GAMMA BDMG-96Detector bull GM counters
Measurement rangebull Dose rate H(10) 01 μSvh divide 10 Svhbull Dose H(10) 01 μSv divide 10 Sv
Energy range bull 005 divide 3 MeV
Overall dimensions weightbull 40times250 mm 05 kgbull Telescopic pole length 07 m 4 m (by request)
EXTERNAL PROBES GAMMA
BDKS-96B
BDMG-96
BDKS-96S
SPC ldquoDozardquoRadiation monitoring equipment
58 59
GAMMA-SEARCH BDVG-96Detector bull Scintillator NaI(Tl) Oslash 63times63 mm
Measurement rangebull Flux density measurement range 4 divide 2000 s-1cm-2
bull Dose rate H(10) for Cs-137 01 divide 30 μSvhbull Sensitivity for Cs-137 3000 (pulsess-1)( μSvh-1)
Overall dimensions weightbull Oslash 88times400 mm 20 kgbull Modular pole length 16 m
GAMMA-SEARCH BDPG-96Detector bull Scintillator NaI(Tl) Oslash 25times40 mm
Measurement rangebull Flux density measurement range 10 divide 8000 s-1cm-2
bull Dose rate H(10) for Cs-137 01 divide 100 μSvhbull Sensitivity for Cs-137 500 (pulsess-1)( μSvh-1)
Overall dimensions weightbull 50times190times480 mm 10 kgbull Telescopic pole length 07 m
GAMMA-SEARCH BDPG-96MDetector bull Scintillator NaI(Tl) Oslash 18times30 mm
Measurement rangebull Flux density measurement range 10 divide 24000 s-1cm-2
bull Dose rate H(10) for Cs-137 01 divide 300 μSvhbull Sensitivity for Cs-137 200 (pulsess-1)( μSvh-1)
Overall dimensions weightbull Oslash 35times320 mm 05 kgbull Telescopic pole length 07 or 38 m
EXTERNAL PROBES GAMMA
BDVG-96
BDPG-96M
BDPG-96
EXTERNAL PROBESGAMMA BDKG-96 STAINLESS STEEL CASING FOR GEOLOGIC APPLICATIONS WELL LOGGINGDetector bull Scintillator NaI(Tl) Oslash 18times30 mm
Measurement rangebull Flux density measurement range 10 divide 105 s-1cm-2
bull Dose rate H(10) for Cs-137 5 divide 2104 μRhbull Sensitivity for Cs-137 200 (pulsess-1)( μSvh-1)
Overall dimensions weightbull Oslash 38times535 mm 36 kgbull Cable length 10 divide 1000 m
NEUTRON BDMN-96Detector bull Scintillator with ZnS(Ag)
Measurement rangebull Dose rate H(10) 01 μSvh divide 01 Svhbull Dose H(10) 01 μSv divide 10 Sv
Energy range bull 0025 eV divide 10 MeV
Overall dimensions weightbull Detector Oslash 54times200 mm 08 kgbull Moderator Oslash 245 mm 73 kg
NEUTRON-SEARCH BDKN-96Detector bull He-3 counter in polyethilene moderator
Measurement rangebull Dose rate H(10) for Pu-Be 01 μSvh divide 01 Svhbull Dose H(10) for Pu-Be 01 μSv divide 10 Sv
Energy range bull 0025 eV divide 14 MeV
Overall dimensions weightbull 295times142times100 mm 225 kg
BDKG-96M
BDMN-96
BDKN-96
SPC ldquoDozardquoRadiation monitoring equipment
60 61
bull No gas supply neededbull Clothing control detachable right hand detector bull Alpha detector optional connection bull Numeric and color (red green) indication of
control resultsbull LED sensor of hand-foot positioning for start of
measurementbull Automatic compensation of gamma background
and contamination of detectorbull Audible alarm signals of the excess of preset
thresholdsbull Measurement value indication min-1cm-2 or
Bqсm2
Reference standards Nuclear IEC 61098
RZB-05D HAND-FOOT-CLOTHING MONITOR
Physical characteristicsDetectors bull Gamma beta - GM countersbull Alpha - scintillatior ZnS(Ag)
Detecting nuclidesbull Alpha Pu-239 U-234 U-238bull Beta Sr-90+Y-90 F-18 Cs-137 Co-60 Tс-99 O-15
N-13 Sr-89 C-11 I-131 Na-22 Ru-106+Rh-106 Tl-204
bull Gamma Tc-99m I-123
Efficiencybull Alpha
Pu-239 40 U-234 25U-238 15
bull Beta Sr-90 +Y-90 40
Measurement range bull Alpha 1 divide 103 min-1cm-2 bull Beta 10 divide 103 min-1cm-2
bull Gamma 5103 divide 5106 min-1cm-2
Energy range bull Alpha 30 divide 80 MeV bull Beta 008 divide 35 MeV bull Gamma 005 divide 30 MeV
Operation temperature range bull Minus 10 divide +50 ordmС
Electrical characteristicsbull Power supply 220 V 50 Hz
Mechanical characteristicsOverall dimensions weight bull 740times750times1180 mm 45 kg
Versionsbull Withwithout alpha detectorbull Indication (min-1cm-2 ) or (Bqсm2)bull Detectors overall dimensions smbull Hand 178 х 235bull Foot 185 х 436
Whole body contamination monitor RZBA-04-04Mbull No gas supply neededbull Compensation for background gamma radiation
and contamination of detector unitsbull Individual threshold setting for each measure-
ment channelbull Visible and audible alarms ldquoCONTAMINATIONrdquo and
ldquoCLEANrdquo bull Indication of contaminated body parts on the
panel with image of the bodybull Optional remote alpha-detector
Physical characteristicsDetectors bull Beta - GM counters scintillatorsbull Alpha - scintillatior ZnS(Ag)
Measurement range bull Beta 5 divide 15000 min-1cm-2
bull Alpha 01 divide 10000 min-1cm-2
Energy range bull Beta 015 divide 25 MeV bull Alpha 40 divide 56 MeV
Operation temperature range bull +5 divide +50 ordmС
Electrical characteristicsPower supply bull 220 V 50 Hz
Interfaces bull RS-232bull RS-485
Mechanical characteristicsOverall dimensions weight bull 2650times940times930 mm 310 kg
Versionsbull Withwithout alpha detectorbull Indication (min-1cm-2 ) or (Bqсm2)
Reference standards Nuclear IEC 61098
RZBA-04-04MWHOLE BODY CONTAMINATION MONITOR
SPC ldquoDozardquoRadiation monitoring equipment
62 63
RZA-05DALPHA HAND-MONITOR
bull No gas supply needed bull Numeric and color (red green) indication of
control resultsbull LED sensor of hand- positioning for start of
measurementbull Audible alarm signals of the excess of preset
thresholdsbull Measurement value indication min-1cm-2 or
Bqсm2
Physical characteristicsDetectors alpha - scintillatior ZnS(Ag)
Efficiencybull Pu-239 20 bull U-234 14bull U-238 8
Measurement range bull 05 divide 105 min-1cm-2
Energy range bull 41 divide 90 MeV
Operation temperature range bull minus 10 divide +50 ordmС
Electrical characteristicsPower supply bull 220 V 50 Hz
Mechanical characteristicsOverall dimensions weight no more bull 740times1400times1450 mm 70 kg
Reference standards Nuclear IEC 61098
bull Simultaneous measurement of alphabeta activi-ties in the sample
bull Active shielding anti-coincidence background subtraction using GM counters
bull Lead shielding 30 mm
UMF-2000 LOW LEVEL ALPHA- BETA- COUNTER
Physical characteristicsDetectors bull Silicon specrometric detector 500 or 1000 mm2
Measurement range bull Alpha 001 divide 1000 Bq bull Beta 01 divide 3000 Bq
Energy range bull Alpha 35 divide 80 MeV bull Beta 005 divide 35 MeV
Electrical characteristicsPower supply bull 220 V 50 Hz
Interfaces bull RS-232bull USB
Mechanical characteristicsOverall dimensions weight bull 337times286times190 mm 22 kg
Versionsbull Detector area 500 mm2
bull Detector area 1000 mm2
UMF-2000 Detector area 1000 mm2
UMF-2000 Detector area 500 mm2
SpectraDec software for alpha-spectrometric measurements
SPC ldquoDozardquoRadiation monitoring equipment
64 65
DRK DOSE AREA PRODUCT METER
DRK-1bull Diagnostic reference level (DRL) of patients
determinationbull Suitable for all basic types of x-ray machines
Physical characteristicsDetector bull Plane-parallel ionization chamber
Measurement range bull 1 divide 104 cGycm2
Electrical characteristicsPower supply bull 220 V 50 Hz
DRK-1M-CTbull Measuring of dose length product
Physical characteristicsDetector bull Pencil Ionization Chamber
Measurement rangebull 05 divide 109 microGym
DRK-1Mbull Measuring of air kerma on sectional area of the
X-ray beam productbull Measuring of air kerma rate on area productbull Measuring of air kerma ratebull Measuring of air kerma
Physical characteristicsDetector bull Plane-parallel ionization chamber
Measurement rangebull 01 divide 109 microGym2
bull 06 divide 6104 microGym2cbull 30 divide 9105 microGycbull 30 divide 9991011 microGyReference standard IEC 60580 2003
bull Measurement of strontium-90 in the foodstuffs agricultural products etc
bull Measurement of gross beta activity in samplebull Self tests using built-in LED
ldquoPROGRESS-BETArdquo SCINTILLATION BETA SPECTROMETER
Physical characteristicsDetector bull Plastic scintillator Oslash70x10 mm
Sample bull Plate Oslash70 mmbull Weight up to 15 g
Energy range bull 02 divide 30 MeV
Minimum detectable activity of Sr-90 in a 10 g sample on a standard planchet Bqsamplebull In case of absence of K-40 in the sample 01 Bqbull In case the activity of K-40 till 5 Bqg 05 Bq
Electrical characteristics Interface bull USB
Mechanical characteristicsWeight bull No more 50 kg
Complete setBasic complete setbull Detector unit with plastic scintillator integrated
power supply amplifier ADC bull Lead shielding bull ldquoProgressrdquo software bull Сheck source for energetic calibration (Sr-90-Y-90) bull Planchet Oslash 70 mm (5 items) bull Sample dencification device bull Procedure manual for measurement of radio-
nuclidesrsquo activity using the scintillation beta spec-trometer ldquoProgressrdquo
Optional equipment and servicebull Personal computer and printer bull Calibrations for radionuclides not included in the
main library of radionuclides
Progress-Beta
Reference standards IEC 61562
SPC ldquoDozardquoRadiation monitoring equipment
66 67
bull Measurement of gamma activity in foodstuffs soil samples and others environmental objects
bull Identification of radionuclides in the sample bull Automatic correction for sample density bull Self-tests using built-in LED
ldquoPROGRESS-GAMMArdquoSCINTILLATION GAMMA SPECTROMETER
Physical characteristicsDetector bull NaI (Tl) Oslash63times63 mm
Validated measurement geometries bull Marinelli beakers (1 liter) Petri dishes (Oslash90 mm)
etc
Energy range bull 02 divide 30 MeV
Minimum detectable activity Bqsamplebull Cs-137 3 Bqbull Th-232 7 Bqbull Ra-226 8 Bq bull К-40 40 Bq
Electrical characteristics Interface bull USB
Mechanical characteristicsWeight bull No more 120 kg
Complete setBasic complete setbull Scintillation detector unit with NaI (Tl) detector
with integrated power supply amplifier and ADC bull Lead shielding 50 mm bull ldquoProgressrdquo software bull Сheck source for energy calibration (Cs-137 +
K-40)bull Marinelli beakers - 1 liter (5 items) bull Petri dishes Oslash 90 mm (5 items) bull Procedure manual for measurement of activity
of radionuclides using the scintillation gamma spectrometer ldquoProgressrdquo
Optional equipment and servicebull Kit for radon measurements including calibration
of ldquoIC-63rdquo geometry for counting the charcoal samples
bull Personal computer and printer bull Calibrations for user defined geometries bull Calibrations for radionuclides not included in the
main library of radionuclides
Progress-Gamma
Reference standards IEC 61563
ldquoPROGRESS-G(P)rdquoPORTABLE SCINTILLATION GAMMA SPECTROMETERbull Field measurements of gamma activity in environ-
mental objects without sampling (4π geometry)bull Laboratory measurement of gamma activity in
foodstuffs soil samples and others environmental objects
bull Identification of radionuclides in the sample bull Automatic correction for sample densitybull Tests using built-in LED
Physical charachteristicsDetector bull NaI (Tl) Oslash45times50 mmbull Lead shielding 20 mm
Validated measurement geometries bull Marinelli beakers (05 liter) Petri dishes (Oslash90 mm)
etc
Energy range bull 02 divide 30 MeV
Minimum detectable activity in 05-litre Marinelli beaker bull Cs-13710 Bqkgbull К-40100 Bqkgbull Ra-22618 Bqkg bull Th-23216 Bqkg
Minimum detectable activity in 30 min (4π geometry) bull Cs-137 2 Bqkgbull К-40 30 Bqkgbull Ra-226 4 Bqkg bull Th-232 3 Bqkg
Electrical characteristicsPower supply bull Rechargeable batterybull 220 V 50 Hz
Interface bull USB RS-232
Weight bull No more than 60 kg
Complete setBasic complete setbull Scinttillation detector unit with NaI(Tl) bull ldquoProgressrdquo softwarebull Сontrol unit ldquoSputnikrdquo for aquisition and analisys
of spectra with built-in memory for spectral databull Casebull Lead shielding (2 cm) for laboratory usebull 05-litre Marinelli beakers ndash 5 itemsbull Na-22 check sourcebull Power adapter BPS-01bull Operation manualbull Procedure manual for measurement of activity
of radionuclides using the scintillation gamma spectrometer ldquoProgressrdquo
Optional equipment and servicebull Kit for radon measurements with charcoalbull Built-in dose rate meterbull Additional memory (RAM) for storage of 64
spectrabull Additional power adapterbull Notebook and printer
Progress-Gamma
Reference standards IEC 61563
SPC ldquoDozardquoRadiation monitoring equipment
68 69
Physical characteristicsDetectorbull Scintillation detector ZnS (Oslash 60 mm)
Samplebull Thin sample - diameter up to 70 mm bull Preparation technique - electro-depositionbull Thick sample - diameter 70 mm weight
200300 mg bull Preparation technique - application of powders
(prepared by radiochemical concentration by water evaporation or by pounding of mineral samples) onto a planchet with the help of spirit
Energy rangebull 15 divide 8 MeV
Minimum detectable activitybull Thin samples no more than 910-3 Bqsamplebull Thick samples no more than 180 Bqkg
Mechanical characteristicsOverall dimensions weightbull 195times120times210 mm 34 kg
Complete setBasic complete setbull Alpha radiometer ldquoProgress-ARrdquobull Check source (uranium isotopes)
Set of accessoriesbull Procedure manual for measurements of radi-
oactivity using scintillation alpha radiometer ldquoProgress-ARrdquo
bull ldquoProgressrdquo software
ldquoProgress-ARrdquo
bull Measurement of gross activity of alpha emitting radionuclides in thin samples
bull Measurement of gross activity of alpha emitting radionuclides in thick samples
bull Measurement of activity deposited on aerosol filters
ldquoPROGRESS-ARrdquoALPHA RADIOMETER
Several fixed positions of the detector enable to perform measurements in various geometries and to estimate the content ofbull Cs-137 in the whole bodybull I-131 in thyroidbull Co-60 Cs-137 Mn-54 Cr-51 in lungsbull Database for storage of measurement data and
resultsbull Uncertainty calculations based on measurement
databull Self tests using built-in LED
ldquoPROGRESSrdquo WHOLE BODY COUNTER
Physical characteristicsDetectorbull scintillation detector NaI (Tl) Oslash63times63 mm
Energy rangebull 02 divide 28 MeV
Minimum detectable activitybull By Cs-137 in the whole body - 1200 Bqbull By I-131 in thyroid - 100 Bqbull By Co-60 Cs-137 Mn-54 Cr-51 in lungs - 200 Bq
Mechanical characteristicsWeight bull No more than 120 kg
Complete setBasic complete setbull Collimator with rotator and holderbull Detector with incorporated ADCbull Patient chair and table for collimatorbull Check source Na-22bull Procedure manual for lifetime measurement of
gamma-emitting radionuclidesrsquo activity in human body using the gamma-spectrometer of human radiation ldquoProgressrdquo
bull laquoProgressraquo software
Optional equipment and servicebull Program of internal radiation committed internal
radiation effective dose calculation by the stand-ard model
bull Background phantombull Personal computer and printer
Collimator with rotator and holder
SPC ldquoDozardquoRadiation monitoring equipment
70 71
bull Categorization of wastes for the purpose of fur-ther processing including wastes with unknown radionuclide composition
bull Measurements during the incoming waste inspec-tion (accepting for storage disposal)
bull Certification of unconditioned and conditioned wastes in closed containers without opening them (at nuclear plants or at facilities providing collection storage transportation conditioning processing temporal storage and final disposal of radioactive waste)
bull Activity measurement of extended objects in situ without opening the equipment
bull Activity measurement of extended objects after opening (for example assessment of tubes used for oil transportation)
MKG-01D ldquoSADOVNIKrdquoSPECTROMETRY SYSTEM
Physical charachteristicsDetectorbull Detector unit GEM (GMX) with HPGe detector and
multi-positioning cryostat CFG-PMOD4-7 with 7 litre Dewar
bull Dose rate probe BDMG-200
Energy range bull With GEM detector 004 divide 30 MeVbull With GMX detector 0005 divide 15 MeVbull Dose rate probe BDMG-200 ndash 005 divide 30 MeV
Measurement rangebull 110-7 divide 10 Svhbull Relative efficiency of detection (in photopeak) at
13325 MeV (Co-60) 10 divide 150
Electrical characteristicsPower supplybull 220 V 50 Hz
Interfacebull USB
Complete setBasic complete setbull Spectrometric detector unit GEM (GMX) with
HPGe detector and multi-positioning cryostat with 7 litre Dewar
bull Portable digital multichannel analyzer DigiDARTbull Dose rate probe BDMG-200bull Autonomous power supply unit with built-in
batterybull Industrial computer keyboardbull Laser range-finderbull Thermographic printerbull Web-camerabull Device equipped with stepper motor for position-
ing of the spectrometric detectorbull Calibration device with reference sources
(Am-241 Co-60 Ba-133 Eu-152) for energy calibration
bull Removable collimators with end capbull Measurement proceduresbull ldquoClasterrdquo software
bull Measurement of gross alpha activity of alpha-emitting radionuclides
bull Measurement of alpha-emitting radionuclides activity in thin-layer samples meeting alpha-spectrometry requirements
Physical characteristicsDetectorbull Silicon ion-implanted 450 mm2
bull Easy to decontaminate thin windowbull dead layer less than 015 μmbull Background count rate in the range 3 divide 9 MeVbull No more than 09 h-1cm-2 for 450 mm2 detector
Energy rangebull 2 divide 9 MeVbull Lower limit of measurement range (minimum
detectable activity) 01 Bqbull Background count rate no more than 100 counts
in 24 hours
Electrical characteristics Power supplybull 220 V 50 Hz
Interfacebull USB
Complete setBasic complete setbull Detector unit with vacuum measuring chamber
and vacuum control systembull Low noise vacuum pump (type 2FY-05B or
equivalent)bull Check sourcebull ldquoProgressrdquo softwarebull Vacuum tube
MKS-01A ldquoMULTIRAD-ASrdquoALPHA SPECTROMETER
SPC ldquoDozardquoRadiation monitoring equipment
72 73
UCRV-2AIRFLOW MONITOR
bull Monitor of the air flow through filter of centralized multichannel sampling system
bull Radiation monitoring system (RMS) integration for internal exposures determination
bull Volume and flow rate measurements of the air that have passed through a analytical filter
bull Bar-code for filter identificationbull Operation as either standalone unit or as a part of
the RMS
Physical characteristicsMeasurement range of air volume bull 001 divide 9999 m3
Operation temperature range bull minus 20 divide +50 ordmС
Electrical characteristicsPower supply bull 220 V 50 Hz
Interface bull RS-485
PVP-06PORTABLE AIR SAMPLER
Air Sampler PVP-06 is indispensable for monitoring the radiation situation where the concentration of radioactive aerosols in the air does not require a sta-tionary sampling equipment Sampling head PVP-06 provides easy change of filters and cartridges
Purposebull To monitor the concentration of radioactive aero-
sols in the air sites
Controlled aerosolsbull Alpha- and beta-active aerosolsbull Daughter products of decay of radon and thoronbull Iodine isotopes
Physical characteristicsTypes of filtersbull Aerosol AFA-RSP-20bull Iodine AFA SI-20
Flow rate bull 33∙10-4 ndash 233∙10-4 m3s (20 divide 140 l min)
Electrical characteristicsPower supply bull 220 V50 Hzbull The vehicle power supply 108 divide 145 Vbull Internal battery
Minimal working time on internal battery to recharge bull 8 hours
Power consumption (at a flow rate of 100 lmin) bull 40 VA
Environment characteristicsOperating temperature bull minus 10 divide +40 deg C
Maximum humidity bull 90
Pressure bull 860 to 1060 hPA
Noise generated by the pump bull lt 55 dBA at 1 m
Mechanical characteristicsDimensions weight bull 241 times 108 times 160 mm 28 kg
Case material bull Plastic
Complete setbull Air sampler PVP-06bull AC power adapterbull Filters AFA-RSP-20 - 100 pcsbull Packaging for filters - 40 pcsbull Casebull Operation manualbull Calibration certificate
Optional equimpient bull Kit for sampling sorption columns of activated
carbon Ř head of sorption columns with protective
covers Ř activated charcoal SKT-3 - 1 pkg (02 L) Ř charocoal samples SC-13 - 8 pcs
bull Car charger bull Tipod bull Shoulder strapbull Calibration stand bull Filters AFA SI-20 - 100 pcs
Consumablesbull Aerosol filters AFA RSP-20bull Iodine filters AFA SI-20
SPC ldquoDozardquoRadiation monitoring equipment
74 75
Calibration of gamma dose and dose rate meters
Calibration ofbull Ambient equivalent dose H(10) meters (Sv Svh)bull Personal equivalent dose Hp(10) meters (Sv Svh)bull Exposure dose X meters (R Rh)bull Two sources in irradiator bull Select source and collimator opening using
tumbler
UPG-P DESKTOP GAMMA BEAM IRRADIATOR
Physical characteristicsRange of reproduced dose rate bull 05 μSvh divide 10 mSvh (50 μRh divide 100 mRh)
Sources activities bull 6times106 6times108 Bq (02 20 mCi) Cs-137
Overall dimensions bull 1250times400times300 mm
Irradiator weight bull Not more than 37 kg
Calibration bench weight bull Not more than 15 kg
Reference standards IEC 60846 IEC 61526
Physical characteristicsDetectorbull Silicon
Measurement range EEC measurement bull Measurement range of radon EEC
10 divide 10bull106 Bqbullm-3
bull Measurement range of thoron EEC 05 divide 10bull104 Bqbullm-3
bull Air flow through the filter 100plusmn05 lmin
Concentration measurementbull Measurement range of radon-222 concentration
in air 10 divide 20bull106 cpsbull Measurement range of 216Po(ThA)
1bull10-3 divide 1bull102 cpsbull Air sampler flow rate
10plusmn02 lminbull Measurement range of radon-222 concentration
in water samples 6 divide 800 Bqbullkg-1
bull Measurement range of radon-222 flux from soil surface 20 divide 103 mBqsbullm2
bull Measurement range of radon-222 concentration with preliminary sampling of air using air sam-plers 20 divide 107 Bqbullm-3
bull Measurement range of radon-222 concentration in samples of soil air 103 divide 106 Bqbullm-3
Operation temperature range bull 1 divide 35 ordmC
Electrical characteristicsPower supply bull 80 VA
Mechanical characteristicsOverall dimensions weight bull 220times200times165 mm 36 kg
ldquoALPHARAD PLUSrdquoRADON THORON amp THEIR PROGENY MONITORbull Measurement of radon and thoron concentration
and effective equivalent concentration (EEC)bull In the airbull In the indoor air of residential public and industri-
al buildings and structuresbull Measurement of radon in drinking water sourcesbull Measurements of radon flux from the soil surface
at land plots allocated for construction of houses public buildings and industrial facilities
bull Measurements of radon concentration in soil air
Reference standards IEC 61577
SPC ldquoDozardquoRadiation monitoring equipment
76 77
UKPN-2M-D NEUTRON BEAM IRRADIATOR
Reference standards IEC 61005 61322
Calibration of neutron dose and dose rate meters
Calibration ofbull Ambient equivalent dose H(10) meters (Sv Svh)bull Personal equivalent dose Hp(10) meters (Sv Svh)bull Flux density of neutrons (cm-2∙s-1)bull Transfer container for temporary storage of
sources bull Red light signal of source working position
Physical carachteristicsRange of reproduced dose ratebull 20 divide 800 μSvh
Range of reproduced flux densitiesbull 10 divide 400 cm-2∙s-1
Type of a source in use bull Pu-Be
Activity of a source in usebull 24х1011 Bq (with density of 107 s-1)
Overall dimensions weight no morebull 3000x750x2000 mm 300 kg
Required room dimensionsbull not less than 7x3x3 m
Electrical characteristicsPower supply bull 220 V 50 Hz
Calibration of gamma dose and dose rate meters
Calibration ofbull Ambient equivalent dose H(10) meters (Sv Svh)bull Personal equivalent dose Hp(10) meters (Sv Svh)bull Exposure dose X meters (R Rh)bull Four sources in irradiator bull Select source and move to working position
return to storage position using special rodbull Transfer container for temporary storage of
sources bull Red light signal of source working position
UPGD-2M-DGAMMA BEAM IRRADIATOR
Physical characteristicsRange of reproduced dose rate bull 05 μSvh divide 50 mSvh (50 μRh divide 5 Rh)
Maximum activity of source bull 2times1011 Bq (50 Ci) Cs-137
Overall dimensionsbull Irradiator 800times500times500 mmbull Guide rails length 30 mbull Height 16 mbull Weight not more than 700 kgbull Required room dimensions not less than 7x3x3 m
Electrical characteristicsPower supply bull 220 V 50 Hz
UPGD-2M-D
Reference standards IEC 60846 IEC 61526 IEC 61066
SPC ldquoDozardquo
78 79
Contents
MEASURING UNITS
DBG-S11D wide range gamma area monitor 40
UDKS-100 gamma and X-ray area monitor 41
UDMN-100 neutron area monitor 41
ALARM UNITS
BAS-2 ldquoMICROrdquo external visual alarm 42
BZS-2 ldquoMicrordquo external audible alarm 42
Illuminated warning signs 43
ldquoImpulsrdquo external display unit 43
UIM-3D area monitor count rate meter 44
DKG-05D personal gamma dosimeter 46
DVS-02D gamma-neutron personal electronic dosimeter 47
DVGI-8D new pen-type personal ionization chamber dosimeters 48
DKG-02U ldquoARBITERrdquo wide range gamma-dosimeter 49
DKG-07D ldquoDROZDrdquo gamma-dosimeter 50
MKS-15D ldquoSNEGIRrdquo multi ndash purpose radiation survey meter 51
SRPS-05D gamma monitor 52
DOZA-TLD multipurpose TLD system 53
DKS-96 universal radiation survey meter 54
EXTERNAL PROBES ALPHA
Alpha BDZA-96 55
Alpha BDZA-96B 55
Alpha BDZA-96M 55
Alpha BDZA-96S 55
Alpha BDZA-96T 55
EXTERNAL PROBES BETA
Beta BDZB-96 56
Beta BDZB-99 56
Beta BDZB-96B 56
Beta BDZB-96S 56
EXTERNAL PROBES GAMMA
Gamma BDKS-96B 57
Gamma and beta BDKS-96S 57
Gamma BDMG-96 57
EXTERNAL PROBES GAMMA
Gamma-search BDVG-96 58
Gamma-search BDPG-96 58
ContentsRadiation monitoring systemldquoPELIKANrdquo Radiation monitoring system (RMS) 6
BDMG-101 high range gamma area monitor 10
DBG-S11D wide range gamma area monitor 11
BDRG-52 high range gamma area monitor for accident and post-accident conditions 12
UDGP-01 Liquid technological environments monitor 13
UDMN-100 neutron area monitor 14
UDKG-100 Wel Liquid gamma monitor 14
BOP-1M data processing and transmission unit 15
UDA-1AB particulate monitor 16
UDG-1B noble gas monitor 17
UDG-03D noble gas monitor 18
UDI-1B iodine monitor 19
UDGB-01 noble gasesH-3C-14 monitor 20
UDGP-01 steam generator leakage monitor 21
UPPVM air flow parameters monitor 22
ldquoIMPULSrdquo external display unit 23
BI-2 remote display amp alarm unit 24
BASBAS-1s external alarm 25
SKGAV stack monitor 26
RMS software 28
RMS workstation ndash operator console 29
Configurator software 29
RM RACK radiation monitoring rack 30
SRKS-01D criticality accident alarm system 32
ldquoATLANT-Mrdquo environmental radiation monitoring system 34
ldquoBREEZErdquo high-volume air sampler 35
ldquoGAMMA-SENSORrdquo gamma-survey system 36
Radiation monitoring equipmentAREA MONITOR ldquoFREGATrdquo 38
BPI-1D local display unit 39
80
Gamma-search BDPG-96M 58
Gamma BDKG-96 stainless steel casing for geologic applications well logging 59
EXTERNAL PROBES NEUTRON
Neutron BDMN-96 59
Neutron-search BDKN-96 59
RZB-05D Hand-foot-clothing monitor 60
RZBA-04-04M whole body contamination monitor 61
RZA-05D alpha hand-monitor 62
UMF-2000 low level alpha- beta- counter 63
DRK dose area product meter 64
ldquoPROGRESS-BETArdquo scintillation beta spectrometer 65
ldquoPROGRESS-GAMMArdquo scintillation gamma spectrometer 66
ldquoPROGRESS-G(P)rdquo portable scintillation gamma spectrometer 67
ldquoPROGRESS-ARrdquo alpha radiometer 68
ldquoPROGRESSrdquo whole body counter 69
MKG-01D ldquoSADOVNIKrdquo spectrometry system 70
MKS-01A ldquoMULTIRAD-ASrdquo alpha spectrometer 71
UCRV-2 airflow monitor 72
PVP-06 portable air sampler 73
ldquoALPHARAD PLUSrdquo radon thoron amp their progeny monitor 74
UPG-P desktop gamma beam irradiator 75
UPGD-2M-D gamma beam irradiator 76
UKPN-2M-D neutron beam irradiator 77
Radiation monitoring system SPC ldquoDozardquo
28 29
CONFIGURATOR SOFTWAREMaintenance and set-up softwarebull Set-up and verify RMS monitorsbull Control testing adjustment and repair of RMS
monitorsbull Monitors measurement results archive receive
and View bull Communication through RS-232
RMS WORKSTATION ndash OPERATOR CONSOLEOrganization of interaction of the RMS Server and Monitors
Single monitor console includes vandal-proof key-board amp UPS
Reference standard IEC 61559-1 IEC 61559-2
RMS SOFTWAREData acquisition storing and visual representation RMS monitors measurement resultsbull Ethernet IEEE 8023 networkbull Clientserver architecturebull TCPIP protocolbull Oracle based Data Basebull Supremal by means InSat MasterSCADA
Radiation monitoring system SPC ldquoDozardquo
30 31
Delivery setComposition and modification depend on the tasks to be solved using the RM Rack
The rack which is an integral part of RM Rack accommodatesbull Monitors UDA-1AB UDG-1B UDG-03D UDI-1B
UDGB-01Tbull DBG-S11D Wide range gamma area monitor
BDMG-101 High range gamma area monitor UDMN-100 Neutron area monitor BDRG-52R High range gamma area monitor
bull BI-2 Remote display amp alarm unitbull Pump unit BN-01bull Data processing and transmission unit BOP-1Mbull External alarm BAS or BAS-1sbull Equipment of sampling line (flow meters ball
valves filter holder piping solenoid valve)bull Switchboard (intended for switching of all equip-
ment and transfer of data to the upper level via the unified communication channel)
RM RACK RADIATION MONITORING RACK
The radiation monitoring rack (RM Rack) is designed for continuous monitoring of radiation parameters in premises and technological systems at nuclear facil-ities RM Rack can be used as a structural element of the lower-level of RMS at nuclear power plants and other nuclear facilities that involved in obtaining processing use and storage of radioactive materials
FeaturesContinuous automatic monitoring of the alpha- and beta- radioactive aerosol beta-emitting radioactive gases and radioiodine concentrations in the working air and in the air in stacks and others radiation parameters in the facilities
The stand providesbull Primary processing storage and transmission of
measured and related data into the information channel based on the Ethernet IEEE 8023 inter-face (TCPIP protocol)
bull Transfer of required data to the location where the equipment is installed via technological channels based on RS-232 interface
bull Generation of audible and visual warning alarm signals when the preset thresholds are exceeded
bull Display of received data on the LCD
Radiation monitoring system SPC ldquoDozardquo
32 33Reference standards IEC 60860 ANSIANS-83 ISO 7753
Purposebull Detection and recording of criticality accident
(CA) by measuring the absorbed dose rate of gamma-neutron radiation in the premises of monitored object its comparison with a threshold value and generation of audible and visual signals
bull Automatic collection processing storage and display of measurement data and related infor-mation as visual and graphical representation for operators of nuclear safety service
Functions of the systembull Detection and recording of CA events by con-
tinuous measurement of absorbed dose rate of gamma radiation comparison of measured values with preset thresholds generation of signals to activate the alarm
bull Activation of audible visual alarmbull In the event of CA turning on warning signals
ldquoDO NOT ENTERrdquo at illuminated information pan-els placed at the entrances to the controlled area
Featuresbull Data can be transferred to external data commu-
nication channel using RS-485 interface (DiBus data exchange protocol)
bull Automatic self-testing of detection units BR-04D with display of information about the type of fault
bull Possibility for connecting additional a detection and alarm units
bull Ability to function in general regardless of the functioning of components within the agreed scope of nuclear safety tasks
bull Radiation hardness up to 100 Gy
SRKS-01DCRITICALITY ACCIDENT ALARM SYSTEM
Features of softwarebull Collection of information via RS-485 network
displaying it on the PC monitor transmission to remote users archiving and storage
bull Status monitoring and display of values measured by BR-04D and DBG-S11D in locations as per layout of premises
bull Access to archived data with possibility to gener-ate reports for periods determined by operator
bull Maintenance and archiving of a log of dosimetric measurements data and events along with their time stamps
bull Possibility to transfer data to external users via Ethernet network for integrating of CA into higher level systems
Basic complete setLower level bull Control unit with power supplybull BR-04D detection unitsbull BZS-01D audible alarm unitsbull BSS-01D visual alarm unitsbull SIT-01D illuminated warning signsbull PBZ panels for muting audible alarmbull Network communication module
Additional lower layer devicesbull DBG-S11D wide range gamma area monitor
Upper layer bull CDP central display panelbull Service workstation
RS-485
RS-485
RS-4
85
Audible alarm units BZS-01D
Illuminated warning signs SIT-01D
Detection units BR-04D
Network communication
moduleDBG-S11D wide range gamma area monitor
Panels for muting audible alarm
Control unit with power supply
Visual alarm units BSS-01D
RS-485
RS-485
RS-4
85
Audible alarm units BZS-01D
Illuminated warning signs SIT-01D
Detection units BR-04D
Network communication
moduleDBG-S11D wide range gamma area monitor
Panels for muting audible alarm
Control unit with pow-er supply
Visual alarm units BSS-01D
RS-485
RS-4
85
Audible alarm units BZS-01D
Illuminated warning signs SIT-01D
Detection units BR-04D
Network communication
moduleDBG-S11D wide range gamma area monitor
Panels for muting audible alarm
Control unit with power supply
Visual alarm units BSS-01D
RS-485
RS-485
RS-4
85
Audible alarm units BZS-01D
Illuminated warning signs SIT-01D
Detection units BR-04D
Network communication
moduleDBG-S11D wide range gamma area monitor
Panels for muting audible alarm
Control unit with power supply
Visual alarm units BSS-01D
Ethernet
Central display panel Service workstation
RS-485
RS-485
RS-4
85
BZS-01D audible alarm units
SIT-01D illuminated warning signs
BR-04D detection units
Network communication
moduleDBG-S11D wide range gamma area monitor
PBZ panels for muting audible alarm
Control unit with power supply
BSS-01D visual alarm units
Radiation monitoring system SPC ldquoDozardquo
34 35
ldquoBREEZErdquoHIGH-VOLUME AIR SAMPLER
Physical characteristicsbull Measurement range of air flow rate
250 divide 1200 m3hbull Continuous operation time not less than 24 h
Filter materialsbull High-purity glass fiberbull Pure quartz or cellulosebull Filter fabric FPP-15-15
Electrical characteristicsPower supply bull 220380 V 50 Hz
Interfaces bull RS-485bull Ethernetbull GSMGPRS (option)
Environmental characteristicsTemperature range bull minus 40 divide + 40 ordmC
Relative humidity limit at 35 ordmC bull 95
Atmospheric pressure range bull 840 divide 1067 kPa
Versionsbull Standalone unit bull Part of Environmental Radiation Monitoring
System (ERMS)
Type of detection unitsbull Beta block BDZB-100Lbull DBG-S11D wide range gamma area monitorbull Scintillation spectrometric block
The motor of Air Sampler is controlled by an electronic flow sensor that detects changes in the operators pre-set flow rate caused by changes in temperature barometric pressure and pressure drop due to dust loading on filter media It compensates for these changes by adjusting the motor speed to maintain the pre-set flow ratebull Measurement of parameters of ionizing radiation bull Standalone mode of operation or as the part
of Environmental Radiation Monitoring System (ERMS)
Purposebull Environmental Radiation Monitoring System
(ERMS) in the control and buffer areas of the radia-tion and nuclear facilities
Referencesbull Since the year 2000 the system is successfully
operating the ERMSs at 8 Russian nuclear power plants (about 180 monitoring stations)
bull Since the year 2005 the ERMS is operating in the Moscow (about 40 monitoring stations)
bull Since the year 2005 the regional ERMS is under operation in several Russian Federation regions
Basic complete setMonitoring stations bull Data processing and transmission unit BOP-1TA bull Gamma area monitor DBG-S11D
Central data processing station (CDPS)bull Data processing and transmission unit BOP-1TAbull Server
By requestbull Emergency Response and Crisis Management
Centers for enterprisesbull Regional Emergency Response and Crisis Manage-
ment Centersbull rdquoBreezerdquo High-Volume Air Samplerbull Mobile lab with gamma-survey system rdquoGammandash
sensorrdquo
ldquoATLANT-MrdquoENVIRONMENTAL RADIATION MONITORING SYSTEM
Monitoring system for the continuous radiation monitoring of territories and facilities with the data transmission GSMGPRS network
Data transmission bull GSMGPRS
Power supply bull 220 V 50 Hz
Continuous autonomous operation (at 20 ordmC)bull From built-in battery not less than 5 hoursbull From external battery not less than 24 hours
Operation temperature bull Minus 40 divide +50 ordmC
Operation humidity bull Up to 98
Protection bull IP65
Reference standards Nuclear IEC 61017-11991 IEC 61017-21994
36
Radiation Monitoring Equipment
bull Localization of radioactive contaminationsbull Database with dose rate contaminations
spectra measurement date amp time coordi-nates
bull Work as part of mobile laboratory or as part of Environmental Radiation Monitoring System with real-time data transfer
Physical characteristicsDetector bull Scintillation NaI (Tl) GM counters
Measurement rangebull 01 ndash 107 μSvh
Energy range bull 005 ndash 3 MeV
Operation temperature range bull minus 10 divide +50 ordmС
Electrical characteristics bull Power supply 220 V 50 Hz
ldquoGAMMAndashSENSORrdquoGAMMA-SURVEY SYSTEM
SPC ldquoDozardquoRadiation monitoring equipment
38 39
AREA MONITOR ldquoFREGATrdquoArea Monitor ldquoFregatrdquo is designed for building rela-tively simple and inexpensive radiation monitoring systems at such facilities as radionuclide sources storage areas isotope products warehouses nuclear medicine departments PET centers calibration laboratories where sources of ionizing radiation are used etc
Small scale automated radiation monitoring systems built with ldquoFregatrdquo components featuring audible and visual alarms are matched suitable to meet the regulatory radiation safety requirements
Area monitor ldquoFregatrdquo requires virtually no adjust-ment it is simple and convenient for installation and operation
BPI-1D LOCAL DISPLAY UNIT
Display of monitored parameters values received from external measuring devices
Purposebull Processing and display of values of monitored
parameters on information panel bull Comparison of values of monitored parameters
with thresholdsbull Transfer of monitored parametersrsquo values to
networkbull Generation of alarm in case of exceeding of preset
thresholds including external alarm devices
FeaturesTesting the unit and connected devicesbull Visually on the panelbull Using adjustment software when connected to
PC via USB
Automatic self-testing
The panel displays the following informationbull Diagnostic information about the status of con-
nected devicesbull Current date and timebull Values of measured parametersbull Position of measured values with respect to the
thresholds in the form of scales with green yellow and red zones
bull Time history (trend) for each measured value
Physical characteristicsTemperature range bull minus 10 divide + 50 ordmC
Maximum number of connected devicesbull measuring devices 15bull external audible and visual alarm 15
Display diagonal bull 152 cm (6)
Electrical characteristicsbull Interfaces RS-485bull Power supply 220 V 50 Hz 12 divide 24 V
Mechanical characteristicsbull Protection index IP54bull Paint decontaminable
Overall dimensions weightbull 296x248x118 mm 5 kg
DBG-S11D wide range gamma area monitor
UDMN-100 neutron area monitor
Ethernet RS-485
UDKS-100 gamma and X-ray area monitor
BPI-1D Local display unit
BAS-2 ldquoMicrordquo external visual alarm
BZS-2 ldquoMicrordquo external audible alarm
ldquoImpulsrdquo external display unit
Service workstation
Illuminated warning signs
SPC ldquoDozardquoRadiation monitoring equipment
4140
Continuous automatic monitoring of the gamma- X-ray ambient dose equivalent rate
Physical characteristicsbull Detector tissue-equivalent plastic scintillator
Oslash 45times20 mm
Measurement range bull Dose rate measurement range 01 μSvh divide 1 Svh bull Energy range 0015 divide 10 MeV
Mechanical characteristicsbull Protection index IP65bull Paint decontaminable
Overall dimensions weightbull Oslash72times265 mm 15 kg
UDKS-100 GAMMA AND X-RAY AREA MONITOR
UDMN-100 NEUTRON AREA MONITOR
Physical characteristicsbull detector ndash scintillator ZnS(Ag) Li-6
Measurement range bull 01 μSvh divide 01 Svh
Energy range bull 0025 eV divide 100 MeV
Temperature range bull minus 45 divide +50 ordmC
Electrical characteristicsbull Interfaces RS-485
Mechanical characteristicsbull Protection index IP 65bull Paint decontaminable
Overall dimensions weight bull 428times258times347 mm 115 kg
Continuous automatic monitoring of the neutron-radiations ambient dose equivalent ratebull Spherical polyethylene moderator Oslash 239 mm
MEASURING UNITS
DBG-S11D WIDE RANGE GAMMA AREA MONITOR
Continuous automatic monitoring of the gamma- ambient dose equivalent rate
Physical characteristicsbull Detector ndash GM counters
Measurement rangebull DBG-S11D 01 μSvh divide 10 mSvhbull DBG-S11D-01 01 μSvh divide 10 Svhbull DBG-S11D-02 01 μSvh divide 100 Svh
Energy rangebull 005 divide 30 MeV
Temperature range bull minus 40 divide +50 ordmC
Electrical characteristicsbull Interfaces RS-485 USB
Mechanical characteristicsbull Protection index IP 68bull Paint decontaminable
Overall dimensions weightbull DBG-S11D Oslash 68times141 mm 065 kg bull DBG-S11D-01 Oslash 68times179 mm 07 kgbull DBG-S11D-02 Oslash 68times179 mm 07 kg
Versionsbull DBG-S11Dbull DBG-S11D-01bull DBG-S11D-02
Reference standards Nuclear IEC 60846 IEC 60532 EMC IEC 61010 IEC 61000-6-2 Seismic IEC 60980
SPC ldquoDozardquoRadiation monitoring equipment
4342
ALARM UNITS
Generation visual signals of the excess of preset thresholds
Physical characteristicsLength of communication cablebull up to 1200 mbull Alarm Visual alarm green yellow red
Electrical characteristicsbull Power supply +12 V
Mechanical characteristicsbull Protection index IP 23
Overall dimensions weight 160times84times41 mm 02 kg
BAS-2 ldquoMICROrdquo EXTERNAL VISUAL ALARM
Generation audible signals of the excess of preset thresholds
Physical characteristicsLength of communication cablebull up to 1200 mbull Audible alarm 80 divide 100 dB at a distance of 1 m
Electrical characteristicsbull Power supply +12 V
Mechanical characteristicsbull Protection index IP 23
Overall dimensions weight 160times84times41 mm 02 kg
BZS-2 ldquoMICROrdquo EXTERNAL AUDIBLE ALARM
Physical characteristicsLength of communication cablebull up to 1200 m
Electrical characteristicsbull Power supply 220 V 50 Hz
Mechanical characteristicsbull Protection index IP 23
Overall dimensions weight bull 330times110times20 mm 05 kg
Physical characteristicsLength of communication cablebull up to 1200 m
Character height bull ldquoImpuls-910-Rrdquo 100 mmbull ldquoImpuls-915-D4Srdquo 150 mmbull ldquoImpuls-927-D4Srdquo 270 mm
Operating temperature rangebull ldquoImpuls-910-Rrdquo 0 divide +50 degCbull ldquoImpuls-915-D4Srdquo ldquo-727-D4Srdquo minus 40 divide +50 degC
Electrical characteristicsbull Power supply 220 V 50 Hz
Mechanical characteristicsProtection index bull ldquoImpuls-910-R IP 44bull ldquoImpuls-915-D4Srdquo ldquo-727-D4Srdquo IP 65
Overall dimensions weight bull ldquoImpuls-910-Rrdquo 400times160times60 mm 3 kgbull ldquoImpuls-915-D4Srdquo 815times250times80 mm 5 kgbull ldquoImpuls-927-D4Srdquo 1250times330times80 mm 5 kg
ILLUMINATED WARNING SIGNS
ldquoIMPULSrdquo EXTERNAL DISPLAY UNIT
SPC ldquoDozardquoRadiation monitoring equipment
4544
Individual threshold setting for each measurement channel
Continuous area and process monitoring
Collect amp display data from two measurement chan-nels (units with RS-485 or analog pulses)
Audible and visual alarms on exceeding preset thresholds or status of connected devices
Individual threshold setting for each measurement channel
Switching on the external alarm or executive devices when any threshold is exceeded
The wide panel displays the following information bull Values of measured parameters as min-1∙cm-2
s-1∙cm-2 μSvhbull Diagnostic information about the status of con-
nected devicesbull Current date and timebull Position of measured values with respect to the
thresholds in the form of scales with green yellow and red zones
bull Time history (trend) for each measured value
Physical characteristics Measurement range bull Count rate up to 107 CPM (170 kHz)
Operating temperature range bull minus 20 divide +50 ordmC
Electrical characteristics bull Power supply 220 V bull Interfaces USB
Mechanical characteristics bull Protection index IP 65 bull Overall dimensions weight 222times164times73 mm
40 kg
UIM-3D AREA MONITOR COUNT RATE METER
Measurement of alpha radiation flux density
Detector unit BDZA-100 (70 cm2) Measurement range 01 divide 104 min-1∙cm-2
Detector unit BDZA-100B (300 cm2) Measurement range 01 divide 2103 min-1∙cm-2
Measurement of beta radiation flux density
Detector unit BDZB-100 (28 cm2) Measurement range 10 divide 105 min-1∙cm-2
Detector unit BDZB-100L (30 cm2) Measurement range 10 divide 104 min-1∙cm-2
Detector unit BDZB-11D (84 cm2) Measurement range 5 divide 15∙104 min-1∙m-2
OPTIONAL PROBESMeasurement of gamma radiation flux density
Detector units BDEG-03 Measurement range 4 divide 2000 s-1∙cm-2
Detector unit UDKG-100 for operation in the rocks ore liquid media and sludge Measurement range 40 divide 8000 s-1∙cm-2
Measurement of the ambient dose equivalent rate
Detector unit DBG-S11D Measurement range 01 μSvh divide 100 Svh
Measurement of neutron radiation ambient dose equivalent rate
Detector unit BDMN-100 Measurement range 01 μSvh divide 01 Svh
SPC ldquoDozardquoRadiation monitoring equipment
46 47Reference standards Nuclear IEC 61526
Measurement of gamma-radiation personal dose equivalent Hp(10)bull Stand-alone dosimeter or composed of dosimetric
system onebull Audible and visual alarmbull Large memory dose accumulation historiesbull Exclusion of unauthorized intervention in dosim-
etry operation
DKG-05D PERSONAL GAMMA DOSIMETER
Physical characteristicsDetectors bull Silicon
Measurement range bull Dose rate 1 μSvh divide 10 Svhbull Dose 01 μSv divide 15 Sv
Energy range bull 005 divide 30 MeV
Electrical characteristicsbull Power supply rechargeable NiMH battery 1
alcaline battery (type AAA)
Operation timebull Till recharging not less 400 hoursbull With one set batteries not less 1000 hours
Mechanical characteristicsOverall dimensions weight bull 47times26times87 mm (with clip) 70 g
Environmental characteristicsbull IP65bull Temperature range minus 20 divide +45 ordmCbull Humidity up to 98 at 35 ordmCbull Shock vibration and drop resistant
Alarmbull Excess of alarm thresholdsbull Warnings of self-test failure and battery discharge bull Audible alarm 80 dB at 40 cmbull Visual alarm blinking LED
Relative equipmentbull One dosimeter charger ZU-1Mbull Chargestorage cassetes KZU-28KZU-56bull ldquoSmart chargingrdquo feature extends battery life timebull DKG-05D reader US-05bull DKG-05D system reader DVS-01D
Reader-PC interfacebull US-05 USB bull DVS-01D Ethernet
KZU-28
Physical characteristicsDetectors bull Silicon Li-6
Gamma measurement range bull Dose rate 1 μSvh divide 10 Svhbull Dose 01 μSv divide 15 Sv
Gamma energy range bull 005 divide 60 MeV
Neutron measurement range bull Dose rate 1 μSvh divide 2 Svhbull Dose 20 μSv divide 15 Sv
Neutron energy range bull 0025 eV divide 20 MeV
Electrical characteristicsPower supply bull Rechargeable NiMH batterybull Operatiion time till recharging not less 200 hours
Mechanical characteristicsOverall dimensions weight bull 47times26times87 mm (with clip) 70 g
Environmental characteristicsbull IP65bull Temperature range minus 20 divide +40 ordmCbull Humidity up to 75 at 30 ordmCbull Shock vibration and drop resistant
Alarmbull Excess of alarm thresholds bull Warnings of self-test failure and battery discharge bull Audible alarm 80 dB at 40 cmbull Visual alarm blinking LED
Relative equipmentbull One dosimeter charger ZU-1Mbull Chargestorage cassetes KZU-28 KZU-56bull ldquoSmart chargingrdquo feature extends battery life timebull DVS-02D reader UZS-01Sbull DVS-02D system reader DVS-01D
Reader-PC interfacebull UZS-01S USB bull DVS-01D Ethernet
UZS-01DReference standards Nuclear IEC 61526
DVS-02D GAMMA-NEUTRON PERSONAL ELECTRONIC DOSIMETER
Measurement of gamma- and neutron radiations personal dose equivalent Hp(10)bull Stand-alone dosimeter or composed of dosimetric
system onebull Audible and visual alarmbull Large memory dose accumulation historiesbull Exclusion of unauthorized intervention in dosim-
etry operationbull Both albedo thermal neutrons and intermediate
fast neutrons registrationbull Usable in the fields of Pu(Be) Po(Be) Cf and other
neutron sources as well as near nuclear reactors without neutron spectrum estimation
SPC ldquoDozardquoRadiation monitoring equipment
48 49
Dosimeters DVG-03D
DVGI-8D NEW PEN-TYPE PERSONAL IONIZATION CHAMBER DOSIMETERS
Measurement of personal dose equivalent Hp(10) of gamma and X-ray radiationbull Hp(10) of continuous and pulsed gamma and
X-ray radiation bull Electronic reader KSU-1bull Dosimeter DVG-03D with electronic ID bull Personal dose histories in the readerrsquos memorybull Readerrsquos connection with PC for database main-
tenance
Physical characteristicsDetector bull Ionization chamber
Measurement range bull 001 mSv divide 25 mSv
Energy range bull 0015 divide 25 MeV
Temperature range bull Reader KSU-1 +10 divide +50 ordmСbull Dosimeter DVG-03D minus 40 divide +50 ordmС
Electrical characteristicsPower supply bull Reader KSU-1 220 V 50 Hz built-in batteries bull Dosimeter DVG-03D four batteries CR 1025 bull Batteries life 3 yearsbull Readers interfaces RS-232USB 20
Mechanical characteristicsOverall dimensions weightbull Dosimeter DVG-03D Oslash 18times126 mm 005 kgbull Reader KSU-1 235times232times125 mm 28 kg
Reference standards Nuclear IEC 62387-1
DKG-02U ldquoARBITERrdquo WIDE RANGE GAMMA-DOSIMETER
Physical characteristicsDetectors bull GM counters
Measurement rangebull Dose-rate 01 μSvh divide 3 Svhbull Dose 1 μSv divide 100 Sv
Energy range bull 005 divide 3 MeV
Electrical characteristicsbull Power supply 2 alcaline batteries (type AA)bull Batteries life not less 200 hours
Mechanical characteristicsOverall dimensions weight bull 152times82times32 mm 03 kg
Environmental characteristicsbull Temperature range minus 20 divide +50 ordmCbull Humidity up to 90 at +25 ordmCbull Shock vibration and drop resistant
Reference standards Nuclear IEC 60846
Measurement of gamma radiation ambient equiva-lent dose H(10) and dose rate H(10)bull Audible signals (clicks) for radiation condition
estimationbull Analog scale for search modebull Audible and visual alarms of the excess of preset
dose and dose rate thresholds bull Shock-resistant water-proof easy decontamina-
tion casebull 100 measurement results memory with date and
time of measurementbull Indication of total dose accumulated during
exploitation time bull Indication of measurement result statistical
uncertainty
SPC ldquoDozardquoRadiation monitoring equipment
50 51
Physical characteristicsDetectors bull GM counter
Measurement rangebull Dose-rate 01 μSvh divide 3 mSvhbull Dose 1 μSv divide 02 Sv
Energy range bull 005 divide 3 MeV
Temperature range bull Minus 20 divide +50 ordmC
Electrical characteristicsbull Power supply 2 alcaline batteries 15 V (type AA)bull Batteries life not less 200 hours
Mechanical characteristicsOverall dimensions weight bull 122times74times29 mm 025 kg
Reference standards Nuclear IEC 60846
DKG-07D ldquoDROZDrdquoGAMMA-DOSIMETER
Measurement of gamma radiation ambient equiva-lent dose H(10) and dose rate H(10)bull Two independent measurement channels dose
and dose ratebull Audible signals (clicks) for radiation condition
estimationbull Continuous measurement with updating meas-
urement resultbull Measurement result can be obtained with any
desired statistical uncertainty (error)bull Automatic restart when radiation level sharply
changesbull Indication of statistical uncertainty (error) during
measurement process
Continuous measurement with updating measure-ment result
Automatic restart when radiation level sharply changes bull Gamma dose H(10) and dose-rate H(10) meas-
urementbull Beta and gamma contamination surveybull Indication of statistical uncertainty during the
measurementbull Continuous measurement with accuracy increas-
ing with time bull Automatic restart triggered by change of gamma
dose-ratebull Compensation of gamma count rate while meas-
uring beta radiationbull Indication of battery charge levelbull Audible signal of the excess of preset threshold
Physical characteristicsDetectors bull GM counter
Measurement range bull Dose-rate 01 microSvh divide 20 mSvhbull Dose 1 microSv divide 100 Svbull Beta flux density (for Sr-90+Y-90)
10 divide 105 cm-2 min-1
Energy range bull Gamma 005 divide 3 MeVbull Beta 01 divide 3 MeV
Temperature range bull Minus 20 divide +50 ordmC
MKS-15D ldquoSnegirrdquo backside
MKS-15D ldquoSNEGIRrdquoMULTI ndash PURPOSE RADIATION SURVEY METER
Reference standards Nuclear IEC 60846 IEC 60325
Electrical characteristicsbull Power supply 2 alcaline batteries (type AA)bull Battery life not less 400 hours
Mechanical characteristicsOverall dimensions weight bull 124times72times35 mm 035 kg
SPC ldquoDozardquoRadiation monitoring equipment
52 53
Physical characteristicsDetectorbull GM counter
Measurement range bull 01 μSvh divide 20 mSvh
Energy range bull 005 divide 30 MeV
Threshold setting range bull 03 μSvh divide 20 mSvh
Step change of the thresholdbull In the range 03 divide 10 μSvh with the step
001 μSvhbull In the range 10 divide 100 μSvh with the step
01 μSvhbull In the range 100 divide 2000 μSvh with the step
10 μSvh
Electrical characteristicsPower supply bull 220 V 50 Hz bull Relay output
Mechanical characteristicsProtection index bull IP 40
Overall dimensions weight bull 226times120times75 mm 07 kg
Alarmbull Sound alarm 80 divide 100 dBA at distance 1 mbull Visual alarm redbull Connection of the external alarm signaling unit
Reference standards Nuclear IEC 60846 IEC 60532
Continuous automatic monitoring of the ambient dose equivalent rate bull Measurement of gamma dose rate H(10)bull Audible and visual alarm signals for preset
thresholdsbull Switching on the external signaling or executive
devices
SRPS-05D GAMMA MONITOR
Measurement ofbull Gamma and X-ray personal dose equivalent
Hp(10)bull Neutron personal dose equivalent Hp(10)bull Lens dose equivalent Hp(3)bull Skin dose equivalent Hp(007)bull TLD reader day-to-day tests using built-in LEDbull No needs nitrogen for heating
Physical charachteristicsDetectors bull 7LiF Mg Ti (gamma beta)bull 6LiF Mg Ti (neutron)
Gamma and X-ray Hp(10) Measurement range bull 500 μSv divide 10 Sv
Energy range bull 0015 divide 30 MeV
Neutron Hp(10)Measurement range bull 01 mSv divide 100 mSv
Energy range bull 0025 eV divide 10 MeV
Beta and photons Hp(007) Hp(3) Measurement range bull 2 mSv divide 100 Sv
Energy range bull Beta 025 divide 35 MeVbull Photons lt15 keV
Mechanical characteristicsDosimeters overall dimensions weight bull Gamma Hp(10) DTL-2 holder - 62times26times16 mm
16 gbull DTU holder - 42times28times18 mm 8 gbull Lens Hp(3) face skin Hp(007) Oslash 32times16 mm 9 gbull Finger skin Hp(007) 90times20times2 mm 1 gbull Neutron gamma Hp(10) 48times40times20 mm 30 g
Reference standards Nuclear IEC 61066
DTL-2 DTU-2
MKD (A-type) DVNG-M
DOZA-TLD MULTIPURPOSE TLD SYSTEM
SPC ldquoDozardquoRadiation monitoring equipment
54 55
Continuous and pulsed gamma and X-ray dose H(10) and dose-rate measurementbull Alpha beta and gamma contamination surveybull Neutron dose H(10) and dose-rate measurementbull Gamma radiation flux density in boreholes and
liquid media measurement
Electrical characteristicsPower supply bull UIK-05 four C-size batteriesbull UIK-05-01 rechargeable batterybull UIK-06 rechargeable battery
Interfaces bull RS-232bull USB (via adapter)
bull Detector type automatic determination and corre-sponding measurement modes selection
bull Alarm threshold settings ndash for dose dose-rate alpha and beta contaminations
bull ldquoDetectrdquo and ldquoLocaterdquo modes for survey probes
Reference standards Nuclear IEC 60846 IEC 60325 IEC 61005 IEC 62363
Case
UIK-06 control unit165times78times48 mm 03 kg
DKS-96UNIVERSAL RADIATION SURVEY METER
UIK-05 control unit202times86times90 mm 10 kg
BDZA-96
BDZA-96B
BDZA-96M
BDZA-96S
BDZA-96T
EXTERNAL PROBES ALPHAALPHA BDZA-96Detector bull ZnS(Ag) 70 cm2
Measurement range (for Pu-239)bull 01 divide 104 min-1cm-2
Overall dimensions weightbull Oslash 130times240 mm 11 kg
ALPHA BDZA-96BDetector bull ZnS(Ag) 300 сm2
Measurement range (for Pu-239)bull 01 divide 2103 min-1cm-2
Overall dimensions weightbull Oslash 230times290 mm 40 kg
ALPHA BDZA-96MDetector bull ZnS(Ag) 10 сm2
Measurement range (for Pu-239)bull 01 divide 105 min-1cm-2
Overall dimensions weightbull Oslash 65times240 mm 09 kg
ALPHA BDZA-96SDetector bull ZnS(Ag) 30 сm2
Measurement range (for Pu-239)bull 01 divide 5104 min-1cm-2
Overall dimensions weightbull Oslash 90times240 mm 10 kg
ALPHA BDZA-96TDetector bull Silicon 5 сm2
Measurement range (for Pu-239)bull 01 divide 106 min-1cm-2
Overall dimensions weightbull Oslash 50times60 mm 015 kg
SPC ldquoDozardquoRadiation monitoring equipment
56 57
BETA BDZB-96Detector Scintillator 28 сm2
Measurement range (for Sr-90+Y-90)bull 10 divide 105 min-1cm-2
Energy rangebull 03 divide 30 MeV
Overall dimensions weightbull Oslash 90times230 mm 09 kg
BETA BDZB-99Detector bull GM counter 30 сm2
Measurement range (for Sr-90+Y-90)bull 20 divide 104 min-1см-2
Energy rangebull 012 divide 30 MeV
Overall dimensions weightbull Oslash 88times80 mm 04 kgbull Telescopic pole length 07 m
BETA BDZB-96BDetector bull GM counter 80 сm2
Measurement range (for Sr-90+Y-90)bull 3 divide 104 min-1сm-2
Energy rangebull 012 divide 30 MeV
Overall dimensions weightbull 150times200times110 mm 15 kg
BETA BDZB-96Sbull Detector GM counter 15 сm2
Measurement range (for Sr-90+Y-90)bull 10 divide 3104 min-1cm-2
Energy rangebull 012 divide 30 MeV
Overall dimensions weightbull Oslash 65times65 mm 03 kgbull Telescopic pole length 07 m
BDZB-96
BDZB-99
BDZB-96B
BDZB-96S
EXTERNAL PROBES BETA
GAMMA BDKS-96BDetector bull Tissue-equivalent scintillator Oslash 45times20 mm
Measurement rangebull Dose rate H(10) 01 μSvh divide 1 Svhbull Dose H(10) 01 μSv divide 10 Sv
Energy rangebull 0015 divide 10 MeV
Overall dimensions weightbull Oslash 60times250 mm 085 kg
GAMMA AND BETA BDKS-96SDetector bull Double GM counters
Measurement rangebull Gamma dose rate H(10) 01 μSvh divide 1 mSvhbull Gamma dose H(10) 01 μSv divide 10 Svbull Beta 10 divide 3104 min-1cm-2
Energy rangebull Gamma 005 divide 3 MeVbull Beta 012 divide 3 MeV
Overall dimensions weightbull Oslash 80times80 mm 035 kgbull Telescopic pole length 07 m
GAMMA BDMG-96Detector bull GM counters
Measurement rangebull Dose rate H(10) 01 μSvh divide 10 Svhbull Dose H(10) 01 μSv divide 10 Sv
Energy range bull 005 divide 3 MeV
Overall dimensions weightbull 40times250 mm 05 kgbull Telescopic pole length 07 m 4 m (by request)
EXTERNAL PROBES GAMMA
BDKS-96B
BDMG-96
BDKS-96S
SPC ldquoDozardquoRadiation monitoring equipment
58 59
GAMMA-SEARCH BDVG-96Detector bull Scintillator NaI(Tl) Oslash 63times63 mm
Measurement rangebull Flux density measurement range 4 divide 2000 s-1cm-2
bull Dose rate H(10) for Cs-137 01 divide 30 μSvhbull Sensitivity for Cs-137 3000 (pulsess-1)( μSvh-1)
Overall dimensions weightbull Oslash 88times400 mm 20 kgbull Modular pole length 16 m
GAMMA-SEARCH BDPG-96Detector bull Scintillator NaI(Tl) Oslash 25times40 mm
Measurement rangebull Flux density measurement range 10 divide 8000 s-1cm-2
bull Dose rate H(10) for Cs-137 01 divide 100 μSvhbull Sensitivity for Cs-137 500 (pulsess-1)( μSvh-1)
Overall dimensions weightbull 50times190times480 mm 10 kgbull Telescopic pole length 07 m
GAMMA-SEARCH BDPG-96MDetector bull Scintillator NaI(Tl) Oslash 18times30 mm
Measurement rangebull Flux density measurement range 10 divide 24000 s-1cm-2
bull Dose rate H(10) for Cs-137 01 divide 300 μSvhbull Sensitivity for Cs-137 200 (pulsess-1)( μSvh-1)
Overall dimensions weightbull Oslash 35times320 mm 05 kgbull Telescopic pole length 07 or 38 m
EXTERNAL PROBES GAMMA
BDVG-96
BDPG-96M
BDPG-96
EXTERNAL PROBESGAMMA BDKG-96 STAINLESS STEEL CASING FOR GEOLOGIC APPLICATIONS WELL LOGGINGDetector bull Scintillator NaI(Tl) Oslash 18times30 mm
Measurement rangebull Flux density measurement range 10 divide 105 s-1cm-2
bull Dose rate H(10) for Cs-137 5 divide 2104 μRhbull Sensitivity for Cs-137 200 (pulsess-1)( μSvh-1)
Overall dimensions weightbull Oslash 38times535 mm 36 kgbull Cable length 10 divide 1000 m
NEUTRON BDMN-96Detector bull Scintillator with ZnS(Ag)
Measurement rangebull Dose rate H(10) 01 μSvh divide 01 Svhbull Dose H(10) 01 μSv divide 10 Sv
Energy range bull 0025 eV divide 10 MeV
Overall dimensions weightbull Detector Oslash 54times200 mm 08 kgbull Moderator Oslash 245 mm 73 kg
NEUTRON-SEARCH BDKN-96Detector bull He-3 counter in polyethilene moderator
Measurement rangebull Dose rate H(10) for Pu-Be 01 μSvh divide 01 Svhbull Dose H(10) for Pu-Be 01 μSv divide 10 Sv
Energy range bull 0025 eV divide 14 MeV
Overall dimensions weightbull 295times142times100 mm 225 kg
BDKG-96M
BDMN-96
BDKN-96
SPC ldquoDozardquoRadiation monitoring equipment
60 61
bull No gas supply neededbull Clothing control detachable right hand detector bull Alpha detector optional connection bull Numeric and color (red green) indication of
control resultsbull LED sensor of hand-foot positioning for start of
measurementbull Automatic compensation of gamma background
and contamination of detectorbull Audible alarm signals of the excess of preset
thresholdsbull Measurement value indication min-1cm-2 or
Bqсm2
Reference standards Nuclear IEC 61098
RZB-05D HAND-FOOT-CLOTHING MONITOR
Physical characteristicsDetectors bull Gamma beta - GM countersbull Alpha - scintillatior ZnS(Ag)
Detecting nuclidesbull Alpha Pu-239 U-234 U-238bull Beta Sr-90+Y-90 F-18 Cs-137 Co-60 Tс-99 O-15
N-13 Sr-89 C-11 I-131 Na-22 Ru-106+Rh-106 Tl-204
bull Gamma Tc-99m I-123
Efficiencybull Alpha
Pu-239 40 U-234 25U-238 15
bull Beta Sr-90 +Y-90 40
Measurement range bull Alpha 1 divide 103 min-1cm-2 bull Beta 10 divide 103 min-1cm-2
bull Gamma 5103 divide 5106 min-1cm-2
Energy range bull Alpha 30 divide 80 MeV bull Beta 008 divide 35 MeV bull Gamma 005 divide 30 MeV
Operation temperature range bull Minus 10 divide +50 ordmС
Electrical characteristicsbull Power supply 220 V 50 Hz
Mechanical characteristicsOverall dimensions weight bull 740times750times1180 mm 45 kg
Versionsbull Withwithout alpha detectorbull Indication (min-1cm-2 ) or (Bqсm2)bull Detectors overall dimensions smbull Hand 178 х 235bull Foot 185 х 436
Whole body contamination monitor RZBA-04-04Mbull No gas supply neededbull Compensation for background gamma radiation
and contamination of detector unitsbull Individual threshold setting for each measure-
ment channelbull Visible and audible alarms ldquoCONTAMINATIONrdquo and
ldquoCLEANrdquo bull Indication of contaminated body parts on the
panel with image of the bodybull Optional remote alpha-detector
Physical characteristicsDetectors bull Beta - GM counters scintillatorsbull Alpha - scintillatior ZnS(Ag)
Measurement range bull Beta 5 divide 15000 min-1cm-2
bull Alpha 01 divide 10000 min-1cm-2
Energy range bull Beta 015 divide 25 MeV bull Alpha 40 divide 56 MeV
Operation temperature range bull +5 divide +50 ordmС
Electrical characteristicsPower supply bull 220 V 50 Hz
Interfaces bull RS-232bull RS-485
Mechanical characteristicsOverall dimensions weight bull 2650times940times930 mm 310 kg
Versionsbull Withwithout alpha detectorbull Indication (min-1cm-2 ) or (Bqсm2)
Reference standards Nuclear IEC 61098
RZBA-04-04MWHOLE BODY CONTAMINATION MONITOR
SPC ldquoDozardquoRadiation monitoring equipment
62 63
RZA-05DALPHA HAND-MONITOR
bull No gas supply needed bull Numeric and color (red green) indication of
control resultsbull LED sensor of hand- positioning for start of
measurementbull Audible alarm signals of the excess of preset
thresholdsbull Measurement value indication min-1cm-2 or
Bqсm2
Physical characteristicsDetectors alpha - scintillatior ZnS(Ag)
Efficiencybull Pu-239 20 bull U-234 14bull U-238 8
Measurement range bull 05 divide 105 min-1cm-2
Energy range bull 41 divide 90 MeV
Operation temperature range bull minus 10 divide +50 ordmС
Electrical characteristicsPower supply bull 220 V 50 Hz
Mechanical characteristicsOverall dimensions weight no more bull 740times1400times1450 mm 70 kg
Reference standards Nuclear IEC 61098
bull Simultaneous measurement of alphabeta activi-ties in the sample
bull Active shielding anti-coincidence background subtraction using GM counters
bull Lead shielding 30 mm
UMF-2000 LOW LEVEL ALPHA- BETA- COUNTER
Physical characteristicsDetectors bull Silicon specrometric detector 500 or 1000 mm2
Measurement range bull Alpha 001 divide 1000 Bq bull Beta 01 divide 3000 Bq
Energy range bull Alpha 35 divide 80 MeV bull Beta 005 divide 35 MeV
Electrical characteristicsPower supply bull 220 V 50 Hz
Interfaces bull RS-232bull USB
Mechanical characteristicsOverall dimensions weight bull 337times286times190 mm 22 kg
Versionsbull Detector area 500 mm2
bull Detector area 1000 mm2
UMF-2000 Detector area 1000 mm2
UMF-2000 Detector area 500 mm2
SpectraDec software for alpha-spectrometric measurements
SPC ldquoDozardquoRadiation monitoring equipment
64 65
DRK DOSE AREA PRODUCT METER
DRK-1bull Diagnostic reference level (DRL) of patients
determinationbull Suitable for all basic types of x-ray machines
Physical characteristicsDetector bull Plane-parallel ionization chamber
Measurement range bull 1 divide 104 cGycm2
Electrical characteristicsPower supply bull 220 V 50 Hz
DRK-1M-CTbull Measuring of dose length product
Physical characteristicsDetector bull Pencil Ionization Chamber
Measurement rangebull 05 divide 109 microGym
DRK-1Mbull Measuring of air kerma on sectional area of the
X-ray beam productbull Measuring of air kerma rate on area productbull Measuring of air kerma ratebull Measuring of air kerma
Physical characteristicsDetector bull Plane-parallel ionization chamber
Measurement rangebull 01 divide 109 microGym2
bull 06 divide 6104 microGym2cbull 30 divide 9105 microGycbull 30 divide 9991011 microGyReference standard IEC 60580 2003
bull Measurement of strontium-90 in the foodstuffs agricultural products etc
bull Measurement of gross beta activity in samplebull Self tests using built-in LED
ldquoPROGRESS-BETArdquo SCINTILLATION BETA SPECTROMETER
Physical characteristicsDetector bull Plastic scintillator Oslash70x10 mm
Sample bull Plate Oslash70 mmbull Weight up to 15 g
Energy range bull 02 divide 30 MeV
Minimum detectable activity of Sr-90 in a 10 g sample on a standard planchet Bqsamplebull In case of absence of K-40 in the sample 01 Bqbull In case the activity of K-40 till 5 Bqg 05 Bq
Electrical characteristics Interface bull USB
Mechanical characteristicsWeight bull No more 50 kg
Complete setBasic complete setbull Detector unit with plastic scintillator integrated
power supply amplifier ADC bull Lead shielding bull ldquoProgressrdquo software bull Сheck source for energetic calibration (Sr-90-Y-90) bull Planchet Oslash 70 mm (5 items) bull Sample dencification device bull Procedure manual for measurement of radio-
nuclidesrsquo activity using the scintillation beta spec-trometer ldquoProgressrdquo
Optional equipment and servicebull Personal computer and printer bull Calibrations for radionuclides not included in the
main library of radionuclides
Progress-Beta
Reference standards IEC 61562
SPC ldquoDozardquoRadiation monitoring equipment
66 67
bull Measurement of gamma activity in foodstuffs soil samples and others environmental objects
bull Identification of radionuclides in the sample bull Automatic correction for sample density bull Self-tests using built-in LED
ldquoPROGRESS-GAMMArdquoSCINTILLATION GAMMA SPECTROMETER
Physical characteristicsDetector bull NaI (Tl) Oslash63times63 mm
Validated measurement geometries bull Marinelli beakers (1 liter) Petri dishes (Oslash90 mm)
etc
Energy range bull 02 divide 30 MeV
Minimum detectable activity Bqsamplebull Cs-137 3 Bqbull Th-232 7 Bqbull Ra-226 8 Bq bull К-40 40 Bq
Electrical characteristics Interface bull USB
Mechanical characteristicsWeight bull No more 120 kg
Complete setBasic complete setbull Scintillation detector unit with NaI (Tl) detector
with integrated power supply amplifier and ADC bull Lead shielding 50 mm bull ldquoProgressrdquo software bull Сheck source for energy calibration (Cs-137 +
K-40)bull Marinelli beakers - 1 liter (5 items) bull Petri dishes Oslash 90 mm (5 items) bull Procedure manual for measurement of activity
of radionuclides using the scintillation gamma spectrometer ldquoProgressrdquo
Optional equipment and servicebull Kit for radon measurements including calibration
of ldquoIC-63rdquo geometry for counting the charcoal samples
bull Personal computer and printer bull Calibrations for user defined geometries bull Calibrations for radionuclides not included in the
main library of radionuclides
Progress-Gamma
Reference standards IEC 61563
ldquoPROGRESS-G(P)rdquoPORTABLE SCINTILLATION GAMMA SPECTROMETERbull Field measurements of gamma activity in environ-
mental objects without sampling (4π geometry)bull Laboratory measurement of gamma activity in
foodstuffs soil samples and others environmental objects
bull Identification of radionuclides in the sample bull Automatic correction for sample densitybull Tests using built-in LED
Physical charachteristicsDetector bull NaI (Tl) Oslash45times50 mmbull Lead shielding 20 mm
Validated measurement geometries bull Marinelli beakers (05 liter) Petri dishes (Oslash90 mm)
etc
Energy range bull 02 divide 30 MeV
Minimum detectable activity in 05-litre Marinelli beaker bull Cs-13710 Bqkgbull К-40100 Bqkgbull Ra-22618 Bqkg bull Th-23216 Bqkg
Minimum detectable activity in 30 min (4π geometry) bull Cs-137 2 Bqkgbull К-40 30 Bqkgbull Ra-226 4 Bqkg bull Th-232 3 Bqkg
Electrical characteristicsPower supply bull Rechargeable batterybull 220 V 50 Hz
Interface bull USB RS-232
Weight bull No more than 60 kg
Complete setBasic complete setbull Scinttillation detector unit with NaI(Tl) bull ldquoProgressrdquo softwarebull Сontrol unit ldquoSputnikrdquo for aquisition and analisys
of spectra with built-in memory for spectral databull Casebull Lead shielding (2 cm) for laboratory usebull 05-litre Marinelli beakers ndash 5 itemsbull Na-22 check sourcebull Power adapter BPS-01bull Operation manualbull Procedure manual for measurement of activity
of radionuclides using the scintillation gamma spectrometer ldquoProgressrdquo
Optional equipment and servicebull Kit for radon measurements with charcoalbull Built-in dose rate meterbull Additional memory (RAM) for storage of 64
spectrabull Additional power adapterbull Notebook and printer
Progress-Gamma
Reference standards IEC 61563
SPC ldquoDozardquoRadiation monitoring equipment
68 69
Physical characteristicsDetectorbull Scintillation detector ZnS (Oslash 60 mm)
Samplebull Thin sample - diameter up to 70 mm bull Preparation technique - electro-depositionbull Thick sample - diameter 70 mm weight
200300 mg bull Preparation technique - application of powders
(prepared by radiochemical concentration by water evaporation or by pounding of mineral samples) onto a planchet with the help of spirit
Energy rangebull 15 divide 8 MeV
Minimum detectable activitybull Thin samples no more than 910-3 Bqsamplebull Thick samples no more than 180 Bqkg
Mechanical characteristicsOverall dimensions weightbull 195times120times210 mm 34 kg
Complete setBasic complete setbull Alpha radiometer ldquoProgress-ARrdquobull Check source (uranium isotopes)
Set of accessoriesbull Procedure manual for measurements of radi-
oactivity using scintillation alpha radiometer ldquoProgress-ARrdquo
bull ldquoProgressrdquo software
ldquoProgress-ARrdquo
bull Measurement of gross activity of alpha emitting radionuclides in thin samples
bull Measurement of gross activity of alpha emitting radionuclides in thick samples
bull Measurement of activity deposited on aerosol filters
ldquoPROGRESS-ARrdquoALPHA RADIOMETER
Several fixed positions of the detector enable to perform measurements in various geometries and to estimate the content ofbull Cs-137 in the whole bodybull I-131 in thyroidbull Co-60 Cs-137 Mn-54 Cr-51 in lungsbull Database for storage of measurement data and
resultsbull Uncertainty calculations based on measurement
databull Self tests using built-in LED
ldquoPROGRESSrdquo WHOLE BODY COUNTER
Physical characteristicsDetectorbull scintillation detector NaI (Tl) Oslash63times63 mm
Energy rangebull 02 divide 28 MeV
Minimum detectable activitybull By Cs-137 in the whole body - 1200 Bqbull By I-131 in thyroid - 100 Bqbull By Co-60 Cs-137 Mn-54 Cr-51 in lungs - 200 Bq
Mechanical characteristicsWeight bull No more than 120 kg
Complete setBasic complete setbull Collimator with rotator and holderbull Detector with incorporated ADCbull Patient chair and table for collimatorbull Check source Na-22bull Procedure manual for lifetime measurement of
gamma-emitting radionuclidesrsquo activity in human body using the gamma-spectrometer of human radiation ldquoProgressrdquo
bull laquoProgressraquo software
Optional equipment and servicebull Program of internal radiation committed internal
radiation effective dose calculation by the stand-ard model
bull Background phantombull Personal computer and printer
Collimator with rotator and holder
SPC ldquoDozardquoRadiation monitoring equipment
70 71
bull Categorization of wastes for the purpose of fur-ther processing including wastes with unknown radionuclide composition
bull Measurements during the incoming waste inspec-tion (accepting for storage disposal)
bull Certification of unconditioned and conditioned wastes in closed containers without opening them (at nuclear plants or at facilities providing collection storage transportation conditioning processing temporal storage and final disposal of radioactive waste)
bull Activity measurement of extended objects in situ without opening the equipment
bull Activity measurement of extended objects after opening (for example assessment of tubes used for oil transportation)
MKG-01D ldquoSADOVNIKrdquoSPECTROMETRY SYSTEM
Physical charachteristicsDetectorbull Detector unit GEM (GMX) with HPGe detector and
multi-positioning cryostat CFG-PMOD4-7 with 7 litre Dewar
bull Dose rate probe BDMG-200
Energy range bull With GEM detector 004 divide 30 MeVbull With GMX detector 0005 divide 15 MeVbull Dose rate probe BDMG-200 ndash 005 divide 30 MeV
Measurement rangebull 110-7 divide 10 Svhbull Relative efficiency of detection (in photopeak) at
13325 MeV (Co-60) 10 divide 150
Electrical characteristicsPower supplybull 220 V 50 Hz
Interfacebull USB
Complete setBasic complete setbull Spectrometric detector unit GEM (GMX) with
HPGe detector and multi-positioning cryostat with 7 litre Dewar
bull Portable digital multichannel analyzer DigiDARTbull Dose rate probe BDMG-200bull Autonomous power supply unit with built-in
batterybull Industrial computer keyboardbull Laser range-finderbull Thermographic printerbull Web-camerabull Device equipped with stepper motor for position-
ing of the spectrometric detectorbull Calibration device with reference sources
(Am-241 Co-60 Ba-133 Eu-152) for energy calibration
bull Removable collimators with end capbull Measurement proceduresbull ldquoClasterrdquo software
bull Measurement of gross alpha activity of alpha-emitting radionuclides
bull Measurement of alpha-emitting radionuclides activity in thin-layer samples meeting alpha-spectrometry requirements
Physical characteristicsDetectorbull Silicon ion-implanted 450 mm2
bull Easy to decontaminate thin windowbull dead layer less than 015 μmbull Background count rate in the range 3 divide 9 MeVbull No more than 09 h-1cm-2 for 450 mm2 detector
Energy rangebull 2 divide 9 MeVbull Lower limit of measurement range (minimum
detectable activity) 01 Bqbull Background count rate no more than 100 counts
in 24 hours
Electrical characteristics Power supplybull 220 V 50 Hz
Interfacebull USB
Complete setBasic complete setbull Detector unit with vacuum measuring chamber
and vacuum control systembull Low noise vacuum pump (type 2FY-05B or
equivalent)bull Check sourcebull ldquoProgressrdquo softwarebull Vacuum tube
MKS-01A ldquoMULTIRAD-ASrdquoALPHA SPECTROMETER
SPC ldquoDozardquoRadiation monitoring equipment
72 73
UCRV-2AIRFLOW MONITOR
bull Monitor of the air flow through filter of centralized multichannel sampling system
bull Radiation monitoring system (RMS) integration for internal exposures determination
bull Volume and flow rate measurements of the air that have passed through a analytical filter
bull Bar-code for filter identificationbull Operation as either standalone unit or as a part of
the RMS
Physical characteristicsMeasurement range of air volume bull 001 divide 9999 m3
Operation temperature range bull minus 20 divide +50 ordmС
Electrical characteristicsPower supply bull 220 V 50 Hz
Interface bull RS-485
PVP-06PORTABLE AIR SAMPLER
Air Sampler PVP-06 is indispensable for monitoring the radiation situation where the concentration of radioactive aerosols in the air does not require a sta-tionary sampling equipment Sampling head PVP-06 provides easy change of filters and cartridges
Purposebull To monitor the concentration of radioactive aero-
sols in the air sites
Controlled aerosolsbull Alpha- and beta-active aerosolsbull Daughter products of decay of radon and thoronbull Iodine isotopes
Physical characteristicsTypes of filtersbull Aerosol AFA-RSP-20bull Iodine AFA SI-20
Flow rate bull 33∙10-4 ndash 233∙10-4 m3s (20 divide 140 l min)
Electrical characteristicsPower supply bull 220 V50 Hzbull The vehicle power supply 108 divide 145 Vbull Internal battery
Minimal working time on internal battery to recharge bull 8 hours
Power consumption (at a flow rate of 100 lmin) bull 40 VA
Environment characteristicsOperating temperature bull minus 10 divide +40 deg C
Maximum humidity bull 90
Pressure bull 860 to 1060 hPA
Noise generated by the pump bull lt 55 dBA at 1 m
Mechanical characteristicsDimensions weight bull 241 times 108 times 160 mm 28 kg
Case material bull Plastic
Complete setbull Air sampler PVP-06bull AC power adapterbull Filters AFA-RSP-20 - 100 pcsbull Packaging for filters - 40 pcsbull Casebull Operation manualbull Calibration certificate
Optional equimpient bull Kit for sampling sorption columns of activated
carbon Ř head of sorption columns with protective
covers Ř activated charcoal SKT-3 - 1 pkg (02 L) Ř charocoal samples SC-13 - 8 pcs
bull Car charger bull Tipod bull Shoulder strapbull Calibration stand bull Filters AFA SI-20 - 100 pcs
Consumablesbull Aerosol filters AFA RSP-20bull Iodine filters AFA SI-20
SPC ldquoDozardquoRadiation monitoring equipment
74 75
Calibration of gamma dose and dose rate meters
Calibration ofbull Ambient equivalent dose H(10) meters (Sv Svh)bull Personal equivalent dose Hp(10) meters (Sv Svh)bull Exposure dose X meters (R Rh)bull Two sources in irradiator bull Select source and collimator opening using
tumbler
UPG-P DESKTOP GAMMA BEAM IRRADIATOR
Physical characteristicsRange of reproduced dose rate bull 05 μSvh divide 10 mSvh (50 μRh divide 100 mRh)
Sources activities bull 6times106 6times108 Bq (02 20 mCi) Cs-137
Overall dimensions bull 1250times400times300 mm
Irradiator weight bull Not more than 37 kg
Calibration bench weight bull Not more than 15 kg
Reference standards IEC 60846 IEC 61526
Physical characteristicsDetectorbull Silicon
Measurement range EEC measurement bull Measurement range of radon EEC
10 divide 10bull106 Bqbullm-3
bull Measurement range of thoron EEC 05 divide 10bull104 Bqbullm-3
bull Air flow through the filter 100plusmn05 lmin
Concentration measurementbull Measurement range of radon-222 concentration
in air 10 divide 20bull106 cpsbull Measurement range of 216Po(ThA)
1bull10-3 divide 1bull102 cpsbull Air sampler flow rate
10plusmn02 lminbull Measurement range of radon-222 concentration
in water samples 6 divide 800 Bqbullkg-1
bull Measurement range of radon-222 flux from soil surface 20 divide 103 mBqsbullm2
bull Measurement range of radon-222 concentration with preliminary sampling of air using air sam-plers 20 divide 107 Bqbullm-3
bull Measurement range of radon-222 concentration in samples of soil air 103 divide 106 Bqbullm-3
Operation temperature range bull 1 divide 35 ordmC
Electrical characteristicsPower supply bull 80 VA
Mechanical characteristicsOverall dimensions weight bull 220times200times165 mm 36 kg
ldquoALPHARAD PLUSrdquoRADON THORON amp THEIR PROGENY MONITORbull Measurement of radon and thoron concentration
and effective equivalent concentration (EEC)bull In the airbull In the indoor air of residential public and industri-
al buildings and structuresbull Measurement of radon in drinking water sourcesbull Measurements of radon flux from the soil surface
at land plots allocated for construction of houses public buildings and industrial facilities
bull Measurements of radon concentration in soil air
Reference standards IEC 61577
SPC ldquoDozardquoRadiation monitoring equipment
76 77
UKPN-2M-D NEUTRON BEAM IRRADIATOR
Reference standards IEC 61005 61322
Calibration of neutron dose and dose rate meters
Calibration ofbull Ambient equivalent dose H(10) meters (Sv Svh)bull Personal equivalent dose Hp(10) meters (Sv Svh)bull Flux density of neutrons (cm-2∙s-1)bull Transfer container for temporary storage of
sources bull Red light signal of source working position
Physical carachteristicsRange of reproduced dose ratebull 20 divide 800 μSvh
Range of reproduced flux densitiesbull 10 divide 400 cm-2∙s-1
Type of a source in use bull Pu-Be
Activity of a source in usebull 24х1011 Bq (with density of 107 s-1)
Overall dimensions weight no morebull 3000x750x2000 mm 300 kg
Required room dimensionsbull not less than 7x3x3 m
Electrical characteristicsPower supply bull 220 V 50 Hz
Calibration of gamma dose and dose rate meters
Calibration ofbull Ambient equivalent dose H(10) meters (Sv Svh)bull Personal equivalent dose Hp(10) meters (Sv Svh)bull Exposure dose X meters (R Rh)bull Four sources in irradiator bull Select source and move to working position
return to storage position using special rodbull Transfer container for temporary storage of
sources bull Red light signal of source working position
UPGD-2M-DGAMMA BEAM IRRADIATOR
Physical characteristicsRange of reproduced dose rate bull 05 μSvh divide 50 mSvh (50 μRh divide 5 Rh)
Maximum activity of source bull 2times1011 Bq (50 Ci) Cs-137
Overall dimensionsbull Irradiator 800times500times500 mmbull Guide rails length 30 mbull Height 16 mbull Weight not more than 700 kgbull Required room dimensions not less than 7x3x3 m
Electrical characteristicsPower supply bull 220 V 50 Hz
UPGD-2M-D
Reference standards IEC 60846 IEC 61526 IEC 61066
SPC ldquoDozardquo
78 79
Contents
MEASURING UNITS
DBG-S11D wide range gamma area monitor 40
UDKS-100 gamma and X-ray area monitor 41
UDMN-100 neutron area monitor 41
ALARM UNITS
BAS-2 ldquoMICROrdquo external visual alarm 42
BZS-2 ldquoMicrordquo external audible alarm 42
Illuminated warning signs 43
ldquoImpulsrdquo external display unit 43
UIM-3D area monitor count rate meter 44
DKG-05D personal gamma dosimeter 46
DVS-02D gamma-neutron personal electronic dosimeter 47
DVGI-8D new pen-type personal ionization chamber dosimeters 48
DKG-02U ldquoARBITERrdquo wide range gamma-dosimeter 49
DKG-07D ldquoDROZDrdquo gamma-dosimeter 50
MKS-15D ldquoSNEGIRrdquo multi ndash purpose radiation survey meter 51
SRPS-05D gamma monitor 52
DOZA-TLD multipurpose TLD system 53
DKS-96 universal radiation survey meter 54
EXTERNAL PROBES ALPHA
Alpha BDZA-96 55
Alpha BDZA-96B 55
Alpha BDZA-96M 55
Alpha BDZA-96S 55
Alpha BDZA-96T 55
EXTERNAL PROBES BETA
Beta BDZB-96 56
Beta BDZB-99 56
Beta BDZB-96B 56
Beta BDZB-96S 56
EXTERNAL PROBES GAMMA
Gamma BDKS-96B 57
Gamma and beta BDKS-96S 57
Gamma BDMG-96 57
EXTERNAL PROBES GAMMA
Gamma-search BDVG-96 58
Gamma-search BDPG-96 58
ContentsRadiation monitoring systemldquoPELIKANrdquo Radiation monitoring system (RMS) 6
BDMG-101 high range gamma area monitor 10
DBG-S11D wide range gamma area monitor 11
BDRG-52 high range gamma area monitor for accident and post-accident conditions 12
UDGP-01 Liquid technological environments monitor 13
UDMN-100 neutron area monitor 14
UDKG-100 Wel Liquid gamma monitor 14
BOP-1M data processing and transmission unit 15
UDA-1AB particulate monitor 16
UDG-1B noble gas monitor 17
UDG-03D noble gas monitor 18
UDI-1B iodine monitor 19
UDGB-01 noble gasesH-3C-14 monitor 20
UDGP-01 steam generator leakage monitor 21
UPPVM air flow parameters monitor 22
ldquoIMPULSrdquo external display unit 23
BI-2 remote display amp alarm unit 24
BASBAS-1s external alarm 25
SKGAV stack monitor 26
RMS software 28
RMS workstation ndash operator console 29
Configurator software 29
RM RACK radiation monitoring rack 30
SRKS-01D criticality accident alarm system 32
ldquoATLANT-Mrdquo environmental radiation monitoring system 34
ldquoBREEZErdquo high-volume air sampler 35
ldquoGAMMA-SENSORrdquo gamma-survey system 36
Radiation monitoring equipmentAREA MONITOR ldquoFREGATrdquo 38
BPI-1D local display unit 39
80
Gamma-search BDPG-96M 58
Gamma BDKG-96 stainless steel casing for geologic applications well logging 59
EXTERNAL PROBES NEUTRON
Neutron BDMN-96 59
Neutron-search BDKN-96 59
RZB-05D Hand-foot-clothing monitor 60
RZBA-04-04M whole body contamination monitor 61
RZA-05D alpha hand-monitor 62
UMF-2000 low level alpha- beta- counter 63
DRK dose area product meter 64
ldquoPROGRESS-BETArdquo scintillation beta spectrometer 65
ldquoPROGRESS-GAMMArdquo scintillation gamma spectrometer 66
ldquoPROGRESS-G(P)rdquo portable scintillation gamma spectrometer 67
ldquoPROGRESS-ARrdquo alpha radiometer 68
ldquoPROGRESSrdquo whole body counter 69
MKG-01D ldquoSADOVNIKrdquo spectrometry system 70
MKS-01A ldquoMULTIRAD-ASrdquo alpha spectrometer 71
UCRV-2 airflow monitor 72
PVP-06 portable air sampler 73
ldquoALPHARAD PLUSrdquo radon thoron amp their progeny monitor 74
UPG-P desktop gamma beam irradiator 75
UPGD-2M-D gamma beam irradiator 76
UKPN-2M-D neutron beam irradiator 77
Radiation monitoring system SPC ldquoDozardquo
30 31
Delivery setComposition and modification depend on the tasks to be solved using the RM Rack
The rack which is an integral part of RM Rack accommodatesbull Monitors UDA-1AB UDG-1B UDG-03D UDI-1B
UDGB-01Tbull DBG-S11D Wide range gamma area monitor
BDMG-101 High range gamma area monitor UDMN-100 Neutron area monitor BDRG-52R High range gamma area monitor
bull BI-2 Remote display amp alarm unitbull Pump unit BN-01bull Data processing and transmission unit BOP-1Mbull External alarm BAS or BAS-1sbull Equipment of sampling line (flow meters ball
valves filter holder piping solenoid valve)bull Switchboard (intended for switching of all equip-
ment and transfer of data to the upper level via the unified communication channel)
RM RACK RADIATION MONITORING RACK
The radiation monitoring rack (RM Rack) is designed for continuous monitoring of radiation parameters in premises and technological systems at nuclear facil-ities RM Rack can be used as a structural element of the lower-level of RMS at nuclear power plants and other nuclear facilities that involved in obtaining processing use and storage of radioactive materials
FeaturesContinuous automatic monitoring of the alpha- and beta- radioactive aerosol beta-emitting radioactive gases and radioiodine concentrations in the working air and in the air in stacks and others radiation parameters in the facilities
The stand providesbull Primary processing storage and transmission of
measured and related data into the information channel based on the Ethernet IEEE 8023 inter-face (TCPIP protocol)
bull Transfer of required data to the location where the equipment is installed via technological channels based on RS-232 interface
bull Generation of audible and visual warning alarm signals when the preset thresholds are exceeded
bull Display of received data on the LCD
Radiation monitoring system SPC ldquoDozardquo
32 33Reference standards IEC 60860 ANSIANS-83 ISO 7753
Purposebull Detection and recording of criticality accident
(CA) by measuring the absorbed dose rate of gamma-neutron radiation in the premises of monitored object its comparison with a threshold value and generation of audible and visual signals
bull Automatic collection processing storage and display of measurement data and related infor-mation as visual and graphical representation for operators of nuclear safety service
Functions of the systembull Detection and recording of CA events by con-
tinuous measurement of absorbed dose rate of gamma radiation comparison of measured values with preset thresholds generation of signals to activate the alarm
bull Activation of audible visual alarmbull In the event of CA turning on warning signals
ldquoDO NOT ENTERrdquo at illuminated information pan-els placed at the entrances to the controlled area
Featuresbull Data can be transferred to external data commu-
nication channel using RS-485 interface (DiBus data exchange protocol)
bull Automatic self-testing of detection units BR-04D with display of information about the type of fault
bull Possibility for connecting additional a detection and alarm units
bull Ability to function in general regardless of the functioning of components within the agreed scope of nuclear safety tasks
bull Radiation hardness up to 100 Gy
SRKS-01DCRITICALITY ACCIDENT ALARM SYSTEM
Features of softwarebull Collection of information via RS-485 network
displaying it on the PC monitor transmission to remote users archiving and storage
bull Status monitoring and display of values measured by BR-04D and DBG-S11D in locations as per layout of premises
bull Access to archived data with possibility to gener-ate reports for periods determined by operator
bull Maintenance and archiving of a log of dosimetric measurements data and events along with their time stamps
bull Possibility to transfer data to external users via Ethernet network for integrating of CA into higher level systems
Basic complete setLower level bull Control unit with power supplybull BR-04D detection unitsbull BZS-01D audible alarm unitsbull BSS-01D visual alarm unitsbull SIT-01D illuminated warning signsbull PBZ panels for muting audible alarmbull Network communication module
Additional lower layer devicesbull DBG-S11D wide range gamma area monitor
Upper layer bull CDP central display panelbull Service workstation
RS-485
RS-485
RS-4
85
Audible alarm units BZS-01D
Illuminated warning signs SIT-01D
Detection units BR-04D
Network communication
moduleDBG-S11D wide range gamma area monitor
Panels for muting audible alarm
Control unit with power supply
Visual alarm units BSS-01D
RS-485
RS-485
RS-4
85
Audible alarm units BZS-01D
Illuminated warning signs SIT-01D
Detection units BR-04D
Network communication
moduleDBG-S11D wide range gamma area monitor
Panels for muting audible alarm
Control unit with pow-er supply
Visual alarm units BSS-01D
RS-485
RS-4
85
Audible alarm units BZS-01D
Illuminated warning signs SIT-01D
Detection units BR-04D
Network communication
moduleDBG-S11D wide range gamma area monitor
Panels for muting audible alarm
Control unit with power supply
Visual alarm units BSS-01D
RS-485
RS-485
RS-4
85
Audible alarm units BZS-01D
Illuminated warning signs SIT-01D
Detection units BR-04D
Network communication
moduleDBG-S11D wide range gamma area monitor
Panels for muting audible alarm
Control unit with power supply
Visual alarm units BSS-01D
Ethernet
Central display panel Service workstation
RS-485
RS-485
RS-4
85
BZS-01D audible alarm units
SIT-01D illuminated warning signs
BR-04D detection units
Network communication
moduleDBG-S11D wide range gamma area monitor
PBZ panels for muting audible alarm
Control unit with power supply
BSS-01D visual alarm units
Radiation monitoring system SPC ldquoDozardquo
34 35
ldquoBREEZErdquoHIGH-VOLUME AIR SAMPLER
Physical characteristicsbull Measurement range of air flow rate
250 divide 1200 m3hbull Continuous operation time not less than 24 h
Filter materialsbull High-purity glass fiberbull Pure quartz or cellulosebull Filter fabric FPP-15-15
Electrical characteristicsPower supply bull 220380 V 50 Hz
Interfaces bull RS-485bull Ethernetbull GSMGPRS (option)
Environmental characteristicsTemperature range bull minus 40 divide + 40 ordmC
Relative humidity limit at 35 ordmC bull 95
Atmospheric pressure range bull 840 divide 1067 kPa
Versionsbull Standalone unit bull Part of Environmental Radiation Monitoring
System (ERMS)
Type of detection unitsbull Beta block BDZB-100Lbull DBG-S11D wide range gamma area monitorbull Scintillation spectrometric block
The motor of Air Sampler is controlled by an electronic flow sensor that detects changes in the operators pre-set flow rate caused by changes in temperature barometric pressure and pressure drop due to dust loading on filter media It compensates for these changes by adjusting the motor speed to maintain the pre-set flow ratebull Measurement of parameters of ionizing radiation bull Standalone mode of operation or as the part
of Environmental Radiation Monitoring System (ERMS)
Purposebull Environmental Radiation Monitoring System
(ERMS) in the control and buffer areas of the radia-tion and nuclear facilities
Referencesbull Since the year 2000 the system is successfully
operating the ERMSs at 8 Russian nuclear power plants (about 180 monitoring stations)
bull Since the year 2005 the ERMS is operating in the Moscow (about 40 monitoring stations)
bull Since the year 2005 the regional ERMS is under operation in several Russian Federation regions
Basic complete setMonitoring stations bull Data processing and transmission unit BOP-1TA bull Gamma area monitor DBG-S11D
Central data processing station (CDPS)bull Data processing and transmission unit BOP-1TAbull Server
By requestbull Emergency Response and Crisis Management
Centers for enterprisesbull Regional Emergency Response and Crisis Manage-
ment Centersbull rdquoBreezerdquo High-Volume Air Samplerbull Mobile lab with gamma-survey system rdquoGammandash
sensorrdquo
ldquoATLANT-MrdquoENVIRONMENTAL RADIATION MONITORING SYSTEM
Monitoring system for the continuous radiation monitoring of territories and facilities with the data transmission GSMGPRS network
Data transmission bull GSMGPRS
Power supply bull 220 V 50 Hz
Continuous autonomous operation (at 20 ordmC)bull From built-in battery not less than 5 hoursbull From external battery not less than 24 hours
Operation temperature bull Minus 40 divide +50 ordmC
Operation humidity bull Up to 98
Protection bull IP65
Reference standards Nuclear IEC 61017-11991 IEC 61017-21994
36
Radiation Monitoring Equipment
bull Localization of radioactive contaminationsbull Database with dose rate contaminations
spectra measurement date amp time coordi-nates
bull Work as part of mobile laboratory or as part of Environmental Radiation Monitoring System with real-time data transfer
Physical characteristicsDetector bull Scintillation NaI (Tl) GM counters
Measurement rangebull 01 ndash 107 μSvh
Energy range bull 005 ndash 3 MeV
Operation temperature range bull minus 10 divide +50 ordmС
Electrical characteristics bull Power supply 220 V 50 Hz
ldquoGAMMAndashSENSORrdquoGAMMA-SURVEY SYSTEM
SPC ldquoDozardquoRadiation monitoring equipment
38 39
AREA MONITOR ldquoFREGATrdquoArea Monitor ldquoFregatrdquo is designed for building rela-tively simple and inexpensive radiation monitoring systems at such facilities as radionuclide sources storage areas isotope products warehouses nuclear medicine departments PET centers calibration laboratories where sources of ionizing radiation are used etc
Small scale automated radiation monitoring systems built with ldquoFregatrdquo components featuring audible and visual alarms are matched suitable to meet the regulatory radiation safety requirements
Area monitor ldquoFregatrdquo requires virtually no adjust-ment it is simple and convenient for installation and operation
BPI-1D LOCAL DISPLAY UNIT
Display of monitored parameters values received from external measuring devices
Purposebull Processing and display of values of monitored
parameters on information panel bull Comparison of values of monitored parameters
with thresholdsbull Transfer of monitored parametersrsquo values to
networkbull Generation of alarm in case of exceeding of preset
thresholds including external alarm devices
FeaturesTesting the unit and connected devicesbull Visually on the panelbull Using adjustment software when connected to
PC via USB
Automatic self-testing
The panel displays the following informationbull Diagnostic information about the status of con-
nected devicesbull Current date and timebull Values of measured parametersbull Position of measured values with respect to the
thresholds in the form of scales with green yellow and red zones
bull Time history (trend) for each measured value
Physical characteristicsTemperature range bull minus 10 divide + 50 ordmC
Maximum number of connected devicesbull measuring devices 15bull external audible and visual alarm 15
Display diagonal bull 152 cm (6)
Electrical characteristicsbull Interfaces RS-485bull Power supply 220 V 50 Hz 12 divide 24 V
Mechanical characteristicsbull Protection index IP54bull Paint decontaminable
Overall dimensions weightbull 296x248x118 mm 5 kg
DBG-S11D wide range gamma area monitor
UDMN-100 neutron area monitor
Ethernet RS-485
UDKS-100 gamma and X-ray area monitor
BPI-1D Local display unit
BAS-2 ldquoMicrordquo external visual alarm
BZS-2 ldquoMicrordquo external audible alarm
ldquoImpulsrdquo external display unit
Service workstation
Illuminated warning signs
SPC ldquoDozardquoRadiation monitoring equipment
4140
Continuous automatic monitoring of the gamma- X-ray ambient dose equivalent rate
Physical characteristicsbull Detector tissue-equivalent plastic scintillator
Oslash 45times20 mm
Measurement range bull Dose rate measurement range 01 μSvh divide 1 Svh bull Energy range 0015 divide 10 MeV
Mechanical characteristicsbull Protection index IP65bull Paint decontaminable
Overall dimensions weightbull Oslash72times265 mm 15 kg
UDKS-100 GAMMA AND X-RAY AREA MONITOR
UDMN-100 NEUTRON AREA MONITOR
Physical characteristicsbull detector ndash scintillator ZnS(Ag) Li-6
Measurement range bull 01 μSvh divide 01 Svh
Energy range bull 0025 eV divide 100 MeV
Temperature range bull minus 45 divide +50 ordmC
Electrical characteristicsbull Interfaces RS-485
Mechanical characteristicsbull Protection index IP 65bull Paint decontaminable
Overall dimensions weight bull 428times258times347 mm 115 kg
Continuous automatic monitoring of the neutron-radiations ambient dose equivalent ratebull Spherical polyethylene moderator Oslash 239 mm
MEASURING UNITS
DBG-S11D WIDE RANGE GAMMA AREA MONITOR
Continuous automatic monitoring of the gamma- ambient dose equivalent rate
Physical characteristicsbull Detector ndash GM counters
Measurement rangebull DBG-S11D 01 μSvh divide 10 mSvhbull DBG-S11D-01 01 μSvh divide 10 Svhbull DBG-S11D-02 01 μSvh divide 100 Svh
Energy rangebull 005 divide 30 MeV
Temperature range bull minus 40 divide +50 ordmC
Electrical characteristicsbull Interfaces RS-485 USB
Mechanical characteristicsbull Protection index IP 68bull Paint decontaminable
Overall dimensions weightbull DBG-S11D Oslash 68times141 mm 065 kg bull DBG-S11D-01 Oslash 68times179 mm 07 kgbull DBG-S11D-02 Oslash 68times179 mm 07 kg
Versionsbull DBG-S11Dbull DBG-S11D-01bull DBG-S11D-02
Reference standards Nuclear IEC 60846 IEC 60532 EMC IEC 61010 IEC 61000-6-2 Seismic IEC 60980
SPC ldquoDozardquoRadiation monitoring equipment
4342
ALARM UNITS
Generation visual signals of the excess of preset thresholds
Physical characteristicsLength of communication cablebull up to 1200 mbull Alarm Visual alarm green yellow red
Electrical characteristicsbull Power supply +12 V
Mechanical characteristicsbull Protection index IP 23
Overall dimensions weight 160times84times41 mm 02 kg
BAS-2 ldquoMICROrdquo EXTERNAL VISUAL ALARM
Generation audible signals of the excess of preset thresholds
Physical characteristicsLength of communication cablebull up to 1200 mbull Audible alarm 80 divide 100 dB at a distance of 1 m
Electrical characteristicsbull Power supply +12 V
Mechanical characteristicsbull Protection index IP 23
Overall dimensions weight 160times84times41 mm 02 kg
BZS-2 ldquoMICROrdquo EXTERNAL AUDIBLE ALARM
Physical characteristicsLength of communication cablebull up to 1200 m
Electrical characteristicsbull Power supply 220 V 50 Hz
Mechanical characteristicsbull Protection index IP 23
Overall dimensions weight bull 330times110times20 mm 05 kg
Physical characteristicsLength of communication cablebull up to 1200 m
Character height bull ldquoImpuls-910-Rrdquo 100 mmbull ldquoImpuls-915-D4Srdquo 150 mmbull ldquoImpuls-927-D4Srdquo 270 mm
Operating temperature rangebull ldquoImpuls-910-Rrdquo 0 divide +50 degCbull ldquoImpuls-915-D4Srdquo ldquo-727-D4Srdquo minus 40 divide +50 degC
Electrical characteristicsbull Power supply 220 V 50 Hz
Mechanical characteristicsProtection index bull ldquoImpuls-910-R IP 44bull ldquoImpuls-915-D4Srdquo ldquo-727-D4Srdquo IP 65
Overall dimensions weight bull ldquoImpuls-910-Rrdquo 400times160times60 mm 3 kgbull ldquoImpuls-915-D4Srdquo 815times250times80 mm 5 kgbull ldquoImpuls-927-D4Srdquo 1250times330times80 mm 5 kg
ILLUMINATED WARNING SIGNS
ldquoIMPULSrdquo EXTERNAL DISPLAY UNIT
SPC ldquoDozardquoRadiation monitoring equipment
4544
Individual threshold setting for each measurement channel
Continuous area and process monitoring
Collect amp display data from two measurement chan-nels (units with RS-485 or analog pulses)
Audible and visual alarms on exceeding preset thresholds or status of connected devices
Individual threshold setting for each measurement channel
Switching on the external alarm or executive devices when any threshold is exceeded
The wide panel displays the following information bull Values of measured parameters as min-1∙cm-2
s-1∙cm-2 μSvhbull Diagnostic information about the status of con-
nected devicesbull Current date and timebull Position of measured values with respect to the
thresholds in the form of scales with green yellow and red zones
bull Time history (trend) for each measured value
Physical characteristics Measurement range bull Count rate up to 107 CPM (170 kHz)
Operating temperature range bull minus 20 divide +50 ordmC
Electrical characteristics bull Power supply 220 V bull Interfaces USB
Mechanical characteristics bull Protection index IP 65 bull Overall dimensions weight 222times164times73 mm
40 kg
UIM-3D AREA MONITOR COUNT RATE METER
Measurement of alpha radiation flux density
Detector unit BDZA-100 (70 cm2) Measurement range 01 divide 104 min-1∙cm-2
Detector unit BDZA-100B (300 cm2) Measurement range 01 divide 2103 min-1∙cm-2
Measurement of beta radiation flux density
Detector unit BDZB-100 (28 cm2) Measurement range 10 divide 105 min-1∙cm-2
Detector unit BDZB-100L (30 cm2) Measurement range 10 divide 104 min-1∙cm-2
Detector unit BDZB-11D (84 cm2) Measurement range 5 divide 15∙104 min-1∙m-2
OPTIONAL PROBESMeasurement of gamma radiation flux density
Detector units BDEG-03 Measurement range 4 divide 2000 s-1∙cm-2
Detector unit UDKG-100 for operation in the rocks ore liquid media and sludge Measurement range 40 divide 8000 s-1∙cm-2
Measurement of the ambient dose equivalent rate
Detector unit DBG-S11D Measurement range 01 μSvh divide 100 Svh
Measurement of neutron radiation ambient dose equivalent rate
Detector unit BDMN-100 Measurement range 01 μSvh divide 01 Svh
SPC ldquoDozardquoRadiation monitoring equipment
46 47Reference standards Nuclear IEC 61526
Measurement of gamma-radiation personal dose equivalent Hp(10)bull Stand-alone dosimeter or composed of dosimetric
system onebull Audible and visual alarmbull Large memory dose accumulation historiesbull Exclusion of unauthorized intervention in dosim-
etry operation
DKG-05D PERSONAL GAMMA DOSIMETER
Physical characteristicsDetectors bull Silicon
Measurement range bull Dose rate 1 μSvh divide 10 Svhbull Dose 01 μSv divide 15 Sv
Energy range bull 005 divide 30 MeV
Electrical characteristicsbull Power supply rechargeable NiMH battery 1
alcaline battery (type AAA)
Operation timebull Till recharging not less 400 hoursbull With one set batteries not less 1000 hours
Mechanical characteristicsOverall dimensions weight bull 47times26times87 mm (with clip) 70 g
Environmental characteristicsbull IP65bull Temperature range minus 20 divide +45 ordmCbull Humidity up to 98 at 35 ordmCbull Shock vibration and drop resistant
Alarmbull Excess of alarm thresholdsbull Warnings of self-test failure and battery discharge bull Audible alarm 80 dB at 40 cmbull Visual alarm blinking LED
Relative equipmentbull One dosimeter charger ZU-1Mbull Chargestorage cassetes KZU-28KZU-56bull ldquoSmart chargingrdquo feature extends battery life timebull DKG-05D reader US-05bull DKG-05D system reader DVS-01D
Reader-PC interfacebull US-05 USB bull DVS-01D Ethernet
KZU-28
Physical characteristicsDetectors bull Silicon Li-6
Gamma measurement range bull Dose rate 1 μSvh divide 10 Svhbull Dose 01 μSv divide 15 Sv
Gamma energy range bull 005 divide 60 MeV
Neutron measurement range bull Dose rate 1 μSvh divide 2 Svhbull Dose 20 μSv divide 15 Sv
Neutron energy range bull 0025 eV divide 20 MeV
Electrical characteristicsPower supply bull Rechargeable NiMH batterybull Operatiion time till recharging not less 200 hours
Mechanical characteristicsOverall dimensions weight bull 47times26times87 mm (with clip) 70 g
Environmental characteristicsbull IP65bull Temperature range minus 20 divide +40 ordmCbull Humidity up to 75 at 30 ordmCbull Shock vibration and drop resistant
Alarmbull Excess of alarm thresholds bull Warnings of self-test failure and battery discharge bull Audible alarm 80 dB at 40 cmbull Visual alarm blinking LED
Relative equipmentbull One dosimeter charger ZU-1Mbull Chargestorage cassetes KZU-28 KZU-56bull ldquoSmart chargingrdquo feature extends battery life timebull DVS-02D reader UZS-01Sbull DVS-02D system reader DVS-01D
Reader-PC interfacebull UZS-01S USB bull DVS-01D Ethernet
UZS-01DReference standards Nuclear IEC 61526
DVS-02D GAMMA-NEUTRON PERSONAL ELECTRONIC DOSIMETER
Measurement of gamma- and neutron radiations personal dose equivalent Hp(10)bull Stand-alone dosimeter or composed of dosimetric
system onebull Audible and visual alarmbull Large memory dose accumulation historiesbull Exclusion of unauthorized intervention in dosim-
etry operationbull Both albedo thermal neutrons and intermediate
fast neutrons registrationbull Usable in the fields of Pu(Be) Po(Be) Cf and other
neutron sources as well as near nuclear reactors without neutron spectrum estimation
SPC ldquoDozardquoRadiation monitoring equipment
48 49
Dosimeters DVG-03D
DVGI-8D NEW PEN-TYPE PERSONAL IONIZATION CHAMBER DOSIMETERS
Measurement of personal dose equivalent Hp(10) of gamma and X-ray radiationbull Hp(10) of continuous and pulsed gamma and
X-ray radiation bull Electronic reader KSU-1bull Dosimeter DVG-03D with electronic ID bull Personal dose histories in the readerrsquos memorybull Readerrsquos connection with PC for database main-
tenance
Physical characteristicsDetector bull Ionization chamber
Measurement range bull 001 mSv divide 25 mSv
Energy range bull 0015 divide 25 MeV
Temperature range bull Reader KSU-1 +10 divide +50 ordmСbull Dosimeter DVG-03D minus 40 divide +50 ordmС
Electrical characteristicsPower supply bull Reader KSU-1 220 V 50 Hz built-in batteries bull Dosimeter DVG-03D four batteries CR 1025 bull Batteries life 3 yearsbull Readers interfaces RS-232USB 20
Mechanical characteristicsOverall dimensions weightbull Dosimeter DVG-03D Oslash 18times126 mm 005 kgbull Reader KSU-1 235times232times125 mm 28 kg
Reference standards Nuclear IEC 62387-1
DKG-02U ldquoARBITERrdquo WIDE RANGE GAMMA-DOSIMETER
Physical characteristicsDetectors bull GM counters
Measurement rangebull Dose-rate 01 μSvh divide 3 Svhbull Dose 1 μSv divide 100 Sv
Energy range bull 005 divide 3 MeV
Electrical characteristicsbull Power supply 2 alcaline batteries (type AA)bull Batteries life not less 200 hours
Mechanical characteristicsOverall dimensions weight bull 152times82times32 mm 03 kg
Environmental characteristicsbull Temperature range minus 20 divide +50 ordmCbull Humidity up to 90 at +25 ordmCbull Shock vibration and drop resistant
Reference standards Nuclear IEC 60846
Measurement of gamma radiation ambient equiva-lent dose H(10) and dose rate H(10)bull Audible signals (clicks) for radiation condition
estimationbull Analog scale for search modebull Audible and visual alarms of the excess of preset
dose and dose rate thresholds bull Shock-resistant water-proof easy decontamina-
tion casebull 100 measurement results memory with date and
time of measurementbull Indication of total dose accumulated during
exploitation time bull Indication of measurement result statistical
uncertainty
SPC ldquoDozardquoRadiation monitoring equipment
50 51
Physical characteristicsDetectors bull GM counter
Measurement rangebull Dose-rate 01 μSvh divide 3 mSvhbull Dose 1 μSv divide 02 Sv
Energy range bull 005 divide 3 MeV
Temperature range bull Minus 20 divide +50 ordmC
Electrical characteristicsbull Power supply 2 alcaline batteries 15 V (type AA)bull Batteries life not less 200 hours
Mechanical characteristicsOverall dimensions weight bull 122times74times29 mm 025 kg
Reference standards Nuclear IEC 60846
DKG-07D ldquoDROZDrdquoGAMMA-DOSIMETER
Measurement of gamma radiation ambient equiva-lent dose H(10) and dose rate H(10)bull Two independent measurement channels dose
and dose ratebull Audible signals (clicks) for radiation condition
estimationbull Continuous measurement with updating meas-
urement resultbull Measurement result can be obtained with any
desired statistical uncertainty (error)bull Automatic restart when radiation level sharply
changesbull Indication of statistical uncertainty (error) during
measurement process
Continuous measurement with updating measure-ment result
Automatic restart when radiation level sharply changes bull Gamma dose H(10) and dose-rate H(10) meas-
urementbull Beta and gamma contamination surveybull Indication of statistical uncertainty during the
measurementbull Continuous measurement with accuracy increas-
ing with time bull Automatic restart triggered by change of gamma
dose-ratebull Compensation of gamma count rate while meas-
uring beta radiationbull Indication of battery charge levelbull Audible signal of the excess of preset threshold
Physical characteristicsDetectors bull GM counter
Measurement range bull Dose-rate 01 microSvh divide 20 mSvhbull Dose 1 microSv divide 100 Svbull Beta flux density (for Sr-90+Y-90)
10 divide 105 cm-2 min-1
Energy range bull Gamma 005 divide 3 MeVbull Beta 01 divide 3 MeV
Temperature range bull Minus 20 divide +50 ordmC
MKS-15D ldquoSnegirrdquo backside
MKS-15D ldquoSNEGIRrdquoMULTI ndash PURPOSE RADIATION SURVEY METER
Reference standards Nuclear IEC 60846 IEC 60325
Electrical characteristicsbull Power supply 2 alcaline batteries (type AA)bull Battery life not less 400 hours
Mechanical characteristicsOverall dimensions weight bull 124times72times35 mm 035 kg
SPC ldquoDozardquoRadiation monitoring equipment
52 53
Physical characteristicsDetectorbull GM counter
Measurement range bull 01 μSvh divide 20 mSvh
Energy range bull 005 divide 30 MeV
Threshold setting range bull 03 μSvh divide 20 mSvh
Step change of the thresholdbull In the range 03 divide 10 μSvh with the step
001 μSvhbull In the range 10 divide 100 μSvh with the step
01 μSvhbull In the range 100 divide 2000 μSvh with the step
10 μSvh
Electrical characteristicsPower supply bull 220 V 50 Hz bull Relay output
Mechanical characteristicsProtection index bull IP 40
Overall dimensions weight bull 226times120times75 mm 07 kg
Alarmbull Sound alarm 80 divide 100 dBA at distance 1 mbull Visual alarm redbull Connection of the external alarm signaling unit
Reference standards Nuclear IEC 60846 IEC 60532
Continuous automatic monitoring of the ambient dose equivalent rate bull Measurement of gamma dose rate H(10)bull Audible and visual alarm signals for preset
thresholdsbull Switching on the external signaling or executive
devices
SRPS-05D GAMMA MONITOR
Measurement ofbull Gamma and X-ray personal dose equivalent
Hp(10)bull Neutron personal dose equivalent Hp(10)bull Lens dose equivalent Hp(3)bull Skin dose equivalent Hp(007)bull TLD reader day-to-day tests using built-in LEDbull No needs nitrogen for heating
Physical charachteristicsDetectors bull 7LiF Mg Ti (gamma beta)bull 6LiF Mg Ti (neutron)
Gamma and X-ray Hp(10) Measurement range bull 500 μSv divide 10 Sv
Energy range bull 0015 divide 30 MeV
Neutron Hp(10)Measurement range bull 01 mSv divide 100 mSv
Energy range bull 0025 eV divide 10 MeV
Beta and photons Hp(007) Hp(3) Measurement range bull 2 mSv divide 100 Sv
Energy range bull Beta 025 divide 35 MeVbull Photons lt15 keV
Mechanical characteristicsDosimeters overall dimensions weight bull Gamma Hp(10) DTL-2 holder - 62times26times16 mm
16 gbull DTU holder - 42times28times18 mm 8 gbull Lens Hp(3) face skin Hp(007) Oslash 32times16 mm 9 gbull Finger skin Hp(007) 90times20times2 mm 1 gbull Neutron gamma Hp(10) 48times40times20 mm 30 g
Reference standards Nuclear IEC 61066
DTL-2 DTU-2
MKD (A-type) DVNG-M
DOZA-TLD MULTIPURPOSE TLD SYSTEM
SPC ldquoDozardquoRadiation monitoring equipment
54 55
Continuous and pulsed gamma and X-ray dose H(10) and dose-rate measurementbull Alpha beta and gamma contamination surveybull Neutron dose H(10) and dose-rate measurementbull Gamma radiation flux density in boreholes and
liquid media measurement
Electrical characteristicsPower supply bull UIK-05 four C-size batteriesbull UIK-05-01 rechargeable batterybull UIK-06 rechargeable battery
Interfaces bull RS-232bull USB (via adapter)
bull Detector type automatic determination and corre-sponding measurement modes selection
bull Alarm threshold settings ndash for dose dose-rate alpha and beta contaminations
bull ldquoDetectrdquo and ldquoLocaterdquo modes for survey probes
Reference standards Nuclear IEC 60846 IEC 60325 IEC 61005 IEC 62363
Case
UIK-06 control unit165times78times48 mm 03 kg
DKS-96UNIVERSAL RADIATION SURVEY METER
UIK-05 control unit202times86times90 mm 10 kg
BDZA-96
BDZA-96B
BDZA-96M
BDZA-96S
BDZA-96T
EXTERNAL PROBES ALPHAALPHA BDZA-96Detector bull ZnS(Ag) 70 cm2
Measurement range (for Pu-239)bull 01 divide 104 min-1cm-2
Overall dimensions weightbull Oslash 130times240 mm 11 kg
ALPHA BDZA-96BDetector bull ZnS(Ag) 300 сm2
Measurement range (for Pu-239)bull 01 divide 2103 min-1cm-2
Overall dimensions weightbull Oslash 230times290 mm 40 kg
ALPHA BDZA-96MDetector bull ZnS(Ag) 10 сm2
Measurement range (for Pu-239)bull 01 divide 105 min-1cm-2
Overall dimensions weightbull Oslash 65times240 mm 09 kg
ALPHA BDZA-96SDetector bull ZnS(Ag) 30 сm2
Measurement range (for Pu-239)bull 01 divide 5104 min-1cm-2
Overall dimensions weightbull Oslash 90times240 mm 10 kg
ALPHA BDZA-96TDetector bull Silicon 5 сm2
Measurement range (for Pu-239)bull 01 divide 106 min-1cm-2
Overall dimensions weightbull Oslash 50times60 mm 015 kg
SPC ldquoDozardquoRadiation monitoring equipment
56 57
BETA BDZB-96Detector Scintillator 28 сm2
Measurement range (for Sr-90+Y-90)bull 10 divide 105 min-1cm-2
Energy rangebull 03 divide 30 MeV
Overall dimensions weightbull Oslash 90times230 mm 09 kg
BETA BDZB-99Detector bull GM counter 30 сm2
Measurement range (for Sr-90+Y-90)bull 20 divide 104 min-1см-2
Energy rangebull 012 divide 30 MeV
Overall dimensions weightbull Oslash 88times80 mm 04 kgbull Telescopic pole length 07 m
BETA BDZB-96BDetector bull GM counter 80 сm2
Measurement range (for Sr-90+Y-90)bull 3 divide 104 min-1сm-2
Energy rangebull 012 divide 30 MeV
Overall dimensions weightbull 150times200times110 mm 15 kg
BETA BDZB-96Sbull Detector GM counter 15 сm2
Measurement range (for Sr-90+Y-90)bull 10 divide 3104 min-1cm-2
Energy rangebull 012 divide 30 MeV
Overall dimensions weightbull Oslash 65times65 mm 03 kgbull Telescopic pole length 07 m
BDZB-96
BDZB-99
BDZB-96B
BDZB-96S
EXTERNAL PROBES BETA
GAMMA BDKS-96BDetector bull Tissue-equivalent scintillator Oslash 45times20 mm
Measurement rangebull Dose rate H(10) 01 μSvh divide 1 Svhbull Dose H(10) 01 μSv divide 10 Sv
Energy rangebull 0015 divide 10 MeV
Overall dimensions weightbull Oslash 60times250 mm 085 kg
GAMMA AND BETA BDKS-96SDetector bull Double GM counters
Measurement rangebull Gamma dose rate H(10) 01 μSvh divide 1 mSvhbull Gamma dose H(10) 01 μSv divide 10 Svbull Beta 10 divide 3104 min-1cm-2
Energy rangebull Gamma 005 divide 3 MeVbull Beta 012 divide 3 MeV
Overall dimensions weightbull Oslash 80times80 mm 035 kgbull Telescopic pole length 07 m
GAMMA BDMG-96Detector bull GM counters
Measurement rangebull Dose rate H(10) 01 μSvh divide 10 Svhbull Dose H(10) 01 μSv divide 10 Sv
Energy range bull 005 divide 3 MeV
Overall dimensions weightbull 40times250 mm 05 kgbull Telescopic pole length 07 m 4 m (by request)
EXTERNAL PROBES GAMMA
BDKS-96B
BDMG-96
BDKS-96S
SPC ldquoDozardquoRadiation monitoring equipment
58 59
GAMMA-SEARCH BDVG-96Detector bull Scintillator NaI(Tl) Oslash 63times63 mm
Measurement rangebull Flux density measurement range 4 divide 2000 s-1cm-2
bull Dose rate H(10) for Cs-137 01 divide 30 μSvhbull Sensitivity for Cs-137 3000 (pulsess-1)( μSvh-1)
Overall dimensions weightbull Oslash 88times400 mm 20 kgbull Modular pole length 16 m
GAMMA-SEARCH BDPG-96Detector bull Scintillator NaI(Tl) Oslash 25times40 mm
Measurement rangebull Flux density measurement range 10 divide 8000 s-1cm-2
bull Dose rate H(10) for Cs-137 01 divide 100 μSvhbull Sensitivity for Cs-137 500 (pulsess-1)( μSvh-1)
Overall dimensions weightbull 50times190times480 mm 10 kgbull Telescopic pole length 07 m
GAMMA-SEARCH BDPG-96MDetector bull Scintillator NaI(Tl) Oslash 18times30 mm
Measurement rangebull Flux density measurement range 10 divide 24000 s-1cm-2
bull Dose rate H(10) for Cs-137 01 divide 300 μSvhbull Sensitivity for Cs-137 200 (pulsess-1)( μSvh-1)
Overall dimensions weightbull Oslash 35times320 mm 05 kgbull Telescopic pole length 07 or 38 m
EXTERNAL PROBES GAMMA
BDVG-96
BDPG-96M
BDPG-96
EXTERNAL PROBESGAMMA BDKG-96 STAINLESS STEEL CASING FOR GEOLOGIC APPLICATIONS WELL LOGGINGDetector bull Scintillator NaI(Tl) Oslash 18times30 mm
Measurement rangebull Flux density measurement range 10 divide 105 s-1cm-2
bull Dose rate H(10) for Cs-137 5 divide 2104 μRhbull Sensitivity for Cs-137 200 (pulsess-1)( μSvh-1)
Overall dimensions weightbull Oslash 38times535 mm 36 kgbull Cable length 10 divide 1000 m
NEUTRON BDMN-96Detector bull Scintillator with ZnS(Ag)
Measurement rangebull Dose rate H(10) 01 μSvh divide 01 Svhbull Dose H(10) 01 μSv divide 10 Sv
Energy range bull 0025 eV divide 10 MeV
Overall dimensions weightbull Detector Oslash 54times200 mm 08 kgbull Moderator Oslash 245 mm 73 kg
NEUTRON-SEARCH BDKN-96Detector bull He-3 counter in polyethilene moderator
Measurement rangebull Dose rate H(10) for Pu-Be 01 μSvh divide 01 Svhbull Dose H(10) for Pu-Be 01 μSv divide 10 Sv
Energy range bull 0025 eV divide 14 MeV
Overall dimensions weightbull 295times142times100 mm 225 kg
BDKG-96M
BDMN-96
BDKN-96
SPC ldquoDozardquoRadiation monitoring equipment
60 61
bull No gas supply neededbull Clothing control detachable right hand detector bull Alpha detector optional connection bull Numeric and color (red green) indication of
control resultsbull LED sensor of hand-foot positioning for start of
measurementbull Automatic compensation of gamma background
and contamination of detectorbull Audible alarm signals of the excess of preset
thresholdsbull Measurement value indication min-1cm-2 or
Bqсm2
Reference standards Nuclear IEC 61098
RZB-05D HAND-FOOT-CLOTHING MONITOR
Physical characteristicsDetectors bull Gamma beta - GM countersbull Alpha - scintillatior ZnS(Ag)
Detecting nuclidesbull Alpha Pu-239 U-234 U-238bull Beta Sr-90+Y-90 F-18 Cs-137 Co-60 Tс-99 O-15
N-13 Sr-89 C-11 I-131 Na-22 Ru-106+Rh-106 Tl-204
bull Gamma Tc-99m I-123
Efficiencybull Alpha
Pu-239 40 U-234 25U-238 15
bull Beta Sr-90 +Y-90 40
Measurement range bull Alpha 1 divide 103 min-1cm-2 bull Beta 10 divide 103 min-1cm-2
bull Gamma 5103 divide 5106 min-1cm-2
Energy range bull Alpha 30 divide 80 MeV bull Beta 008 divide 35 MeV bull Gamma 005 divide 30 MeV
Operation temperature range bull Minus 10 divide +50 ordmС
Electrical characteristicsbull Power supply 220 V 50 Hz
Mechanical characteristicsOverall dimensions weight bull 740times750times1180 mm 45 kg
Versionsbull Withwithout alpha detectorbull Indication (min-1cm-2 ) or (Bqсm2)bull Detectors overall dimensions smbull Hand 178 х 235bull Foot 185 х 436
Whole body contamination monitor RZBA-04-04Mbull No gas supply neededbull Compensation for background gamma radiation
and contamination of detector unitsbull Individual threshold setting for each measure-
ment channelbull Visible and audible alarms ldquoCONTAMINATIONrdquo and
ldquoCLEANrdquo bull Indication of contaminated body parts on the
panel with image of the bodybull Optional remote alpha-detector
Physical characteristicsDetectors bull Beta - GM counters scintillatorsbull Alpha - scintillatior ZnS(Ag)
Measurement range bull Beta 5 divide 15000 min-1cm-2
bull Alpha 01 divide 10000 min-1cm-2
Energy range bull Beta 015 divide 25 MeV bull Alpha 40 divide 56 MeV
Operation temperature range bull +5 divide +50 ordmС
Electrical characteristicsPower supply bull 220 V 50 Hz
Interfaces bull RS-232bull RS-485
Mechanical characteristicsOverall dimensions weight bull 2650times940times930 mm 310 kg
Versionsbull Withwithout alpha detectorbull Indication (min-1cm-2 ) or (Bqсm2)
Reference standards Nuclear IEC 61098
RZBA-04-04MWHOLE BODY CONTAMINATION MONITOR
SPC ldquoDozardquoRadiation monitoring equipment
62 63
RZA-05DALPHA HAND-MONITOR
bull No gas supply needed bull Numeric and color (red green) indication of
control resultsbull LED sensor of hand- positioning for start of
measurementbull Audible alarm signals of the excess of preset
thresholdsbull Measurement value indication min-1cm-2 or
Bqсm2
Physical characteristicsDetectors alpha - scintillatior ZnS(Ag)
Efficiencybull Pu-239 20 bull U-234 14bull U-238 8
Measurement range bull 05 divide 105 min-1cm-2
Energy range bull 41 divide 90 MeV
Operation temperature range bull minus 10 divide +50 ordmС
Electrical characteristicsPower supply bull 220 V 50 Hz
Mechanical characteristicsOverall dimensions weight no more bull 740times1400times1450 mm 70 kg
Reference standards Nuclear IEC 61098
bull Simultaneous measurement of alphabeta activi-ties in the sample
bull Active shielding anti-coincidence background subtraction using GM counters
bull Lead shielding 30 mm
UMF-2000 LOW LEVEL ALPHA- BETA- COUNTER
Physical characteristicsDetectors bull Silicon specrometric detector 500 or 1000 mm2
Measurement range bull Alpha 001 divide 1000 Bq bull Beta 01 divide 3000 Bq
Energy range bull Alpha 35 divide 80 MeV bull Beta 005 divide 35 MeV
Electrical characteristicsPower supply bull 220 V 50 Hz
Interfaces bull RS-232bull USB
Mechanical characteristicsOverall dimensions weight bull 337times286times190 mm 22 kg
Versionsbull Detector area 500 mm2
bull Detector area 1000 mm2
UMF-2000 Detector area 1000 mm2
UMF-2000 Detector area 500 mm2
SpectraDec software for alpha-spectrometric measurements
SPC ldquoDozardquoRadiation monitoring equipment
64 65
DRK DOSE AREA PRODUCT METER
DRK-1bull Diagnostic reference level (DRL) of patients
determinationbull Suitable for all basic types of x-ray machines
Physical characteristicsDetector bull Plane-parallel ionization chamber
Measurement range bull 1 divide 104 cGycm2
Electrical characteristicsPower supply bull 220 V 50 Hz
DRK-1M-CTbull Measuring of dose length product
Physical characteristicsDetector bull Pencil Ionization Chamber
Measurement rangebull 05 divide 109 microGym
DRK-1Mbull Measuring of air kerma on sectional area of the
X-ray beam productbull Measuring of air kerma rate on area productbull Measuring of air kerma ratebull Measuring of air kerma
Physical characteristicsDetector bull Plane-parallel ionization chamber
Measurement rangebull 01 divide 109 microGym2
bull 06 divide 6104 microGym2cbull 30 divide 9105 microGycbull 30 divide 9991011 microGyReference standard IEC 60580 2003
bull Measurement of strontium-90 in the foodstuffs agricultural products etc
bull Measurement of gross beta activity in samplebull Self tests using built-in LED
ldquoPROGRESS-BETArdquo SCINTILLATION BETA SPECTROMETER
Physical characteristicsDetector bull Plastic scintillator Oslash70x10 mm
Sample bull Plate Oslash70 mmbull Weight up to 15 g
Energy range bull 02 divide 30 MeV
Minimum detectable activity of Sr-90 in a 10 g sample on a standard planchet Bqsamplebull In case of absence of K-40 in the sample 01 Bqbull In case the activity of K-40 till 5 Bqg 05 Bq
Electrical characteristics Interface bull USB
Mechanical characteristicsWeight bull No more 50 kg
Complete setBasic complete setbull Detector unit with plastic scintillator integrated
power supply amplifier ADC bull Lead shielding bull ldquoProgressrdquo software bull Сheck source for energetic calibration (Sr-90-Y-90) bull Planchet Oslash 70 mm (5 items) bull Sample dencification device bull Procedure manual for measurement of radio-
nuclidesrsquo activity using the scintillation beta spec-trometer ldquoProgressrdquo
Optional equipment and servicebull Personal computer and printer bull Calibrations for radionuclides not included in the
main library of radionuclides
Progress-Beta
Reference standards IEC 61562
SPC ldquoDozardquoRadiation monitoring equipment
66 67
bull Measurement of gamma activity in foodstuffs soil samples and others environmental objects
bull Identification of radionuclides in the sample bull Automatic correction for sample density bull Self-tests using built-in LED
ldquoPROGRESS-GAMMArdquoSCINTILLATION GAMMA SPECTROMETER
Physical characteristicsDetector bull NaI (Tl) Oslash63times63 mm
Validated measurement geometries bull Marinelli beakers (1 liter) Petri dishes (Oslash90 mm)
etc
Energy range bull 02 divide 30 MeV
Minimum detectable activity Bqsamplebull Cs-137 3 Bqbull Th-232 7 Bqbull Ra-226 8 Bq bull К-40 40 Bq
Electrical characteristics Interface bull USB
Mechanical characteristicsWeight bull No more 120 kg
Complete setBasic complete setbull Scintillation detector unit with NaI (Tl) detector
with integrated power supply amplifier and ADC bull Lead shielding 50 mm bull ldquoProgressrdquo software bull Сheck source for energy calibration (Cs-137 +
K-40)bull Marinelli beakers - 1 liter (5 items) bull Petri dishes Oslash 90 mm (5 items) bull Procedure manual for measurement of activity
of radionuclides using the scintillation gamma spectrometer ldquoProgressrdquo
Optional equipment and servicebull Kit for radon measurements including calibration
of ldquoIC-63rdquo geometry for counting the charcoal samples
bull Personal computer and printer bull Calibrations for user defined geometries bull Calibrations for radionuclides not included in the
main library of radionuclides
Progress-Gamma
Reference standards IEC 61563
ldquoPROGRESS-G(P)rdquoPORTABLE SCINTILLATION GAMMA SPECTROMETERbull Field measurements of gamma activity in environ-
mental objects without sampling (4π geometry)bull Laboratory measurement of gamma activity in
foodstuffs soil samples and others environmental objects
bull Identification of radionuclides in the sample bull Automatic correction for sample densitybull Tests using built-in LED
Physical charachteristicsDetector bull NaI (Tl) Oslash45times50 mmbull Lead shielding 20 mm
Validated measurement geometries bull Marinelli beakers (05 liter) Petri dishes (Oslash90 mm)
etc
Energy range bull 02 divide 30 MeV
Minimum detectable activity in 05-litre Marinelli beaker bull Cs-13710 Bqkgbull К-40100 Bqkgbull Ra-22618 Bqkg bull Th-23216 Bqkg
Minimum detectable activity in 30 min (4π geometry) bull Cs-137 2 Bqkgbull К-40 30 Bqkgbull Ra-226 4 Bqkg bull Th-232 3 Bqkg
Electrical characteristicsPower supply bull Rechargeable batterybull 220 V 50 Hz
Interface bull USB RS-232
Weight bull No more than 60 kg
Complete setBasic complete setbull Scinttillation detector unit with NaI(Tl) bull ldquoProgressrdquo softwarebull Сontrol unit ldquoSputnikrdquo for aquisition and analisys
of spectra with built-in memory for spectral databull Casebull Lead shielding (2 cm) for laboratory usebull 05-litre Marinelli beakers ndash 5 itemsbull Na-22 check sourcebull Power adapter BPS-01bull Operation manualbull Procedure manual for measurement of activity
of radionuclides using the scintillation gamma spectrometer ldquoProgressrdquo
Optional equipment and servicebull Kit for radon measurements with charcoalbull Built-in dose rate meterbull Additional memory (RAM) for storage of 64
spectrabull Additional power adapterbull Notebook and printer
Progress-Gamma
Reference standards IEC 61563
SPC ldquoDozardquoRadiation monitoring equipment
68 69
Physical characteristicsDetectorbull Scintillation detector ZnS (Oslash 60 mm)
Samplebull Thin sample - diameter up to 70 mm bull Preparation technique - electro-depositionbull Thick sample - diameter 70 mm weight
200300 mg bull Preparation technique - application of powders
(prepared by radiochemical concentration by water evaporation or by pounding of mineral samples) onto a planchet with the help of spirit
Energy rangebull 15 divide 8 MeV
Minimum detectable activitybull Thin samples no more than 910-3 Bqsamplebull Thick samples no more than 180 Bqkg
Mechanical characteristicsOverall dimensions weightbull 195times120times210 mm 34 kg
Complete setBasic complete setbull Alpha radiometer ldquoProgress-ARrdquobull Check source (uranium isotopes)
Set of accessoriesbull Procedure manual for measurements of radi-
oactivity using scintillation alpha radiometer ldquoProgress-ARrdquo
bull ldquoProgressrdquo software
ldquoProgress-ARrdquo
bull Measurement of gross activity of alpha emitting radionuclides in thin samples
bull Measurement of gross activity of alpha emitting radionuclides in thick samples
bull Measurement of activity deposited on aerosol filters
ldquoPROGRESS-ARrdquoALPHA RADIOMETER
Several fixed positions of the detector enable to perform measurements in various geometries and to estimate the content ofbull Cs-137 in the whole bodybull I-131 in thyroidbull Co-60 Cs-137 Mn-54 Cr-51 in lungsbull Database for storage of measurement data and
resultsbull Uncertainty calculations based on measurement
databull Self tests using built-in LED
ldquoPROGRESSrdquo WHOLE BODY COUNTER
Physical characteristicsDetectorbull scintillation detector NaI (Tl) Oslash63times63 mm
Energy rangebull 02 divide 28 MeV
Minimum detectable activitybull By Cs-137 in the whole body - 1200 Bqbull By I-131 in thyroid - 100 Bqbull By Co-60 Cs-137 Mn-54 Cr-51 in lungs - 200 Bq
Mechanical characteristicsWeight bull No more than 120 kg
Complete setBasic complete setbull Collimator with rotator and holderbull Detector with incorporated ADCbull Patient chair and table for collimatorbull Check source Na-22bull Procedure manual for lifetime measurement of
gamma-emitting radionuclidesrsquo activity in human body using the gamma-spectrometer of human radiation ldquoProgressrdquo
bull laquoProgressraquo software
Optional equipment and servicebull Program of internal radiation committed internal
radiation effective dose calculation by the stand-ard model
bull Background phantombull Personal computer and printer
Collimator with rotator and holder
SPC ldquoDozardquoRadiation monitoring equipment
70 71
bull Categorization of wastes for the purpose of fur-ther processing including wastes with unknown radionuclide composition
bull Measurements during the incoming waste inspec-tion (accepting for storage disposal)
bull Certification of unconditioned and conditioned wastes in closed containers without opening them (at nuclear plants or at facilities providing collection storage transportation conditioning processing temporal storage and final disposal of radioactive waste)
bull Activity measurement of extended objects in situ without opening the equipment
bull Activity measurement of extended objects after opening (for example assessment of tubes used for oil transportation)
MKG-01D ldquoSADOVNIKrdquoSPECTROMETRY SYSTEM
Physical charachteristicsDetectorbull Detector unit GEM (GMX) with HPGe detector and
multi-positioning cryostat CFG-PMOD4-7 with 7 litre Dewar
bull Dose rate probe BDMG-200
Energy range bull With GEM detector 004 divide 30 MeVbull With GMX detector 0005 divide 15 MeVbull Dose rate probe BDMG-200 ndash 005 divide 30 MeV
Measurement rangebull 110-7 divide 10 Svhbull Relative efficiency of detection (in photopeak) at
13325 MeV (Co-60) 10 divide 150
Electrical characteristicsPower supplybull 220 V 50 Hz
Interfacebull USB
Complete setBasic complete setbull Spectrometric detector unit GEM (GMX) with
HPGe detector and multi-positioning cryostat with 7 litre Dewar
bull Portable digital multichannel analyzer DigiDARTbull Dose rate probe BDMG-200bull Autonomous power supply unit with built-in
batterybull Industrial computer keyboardbull Laser range-finderbull Thermographic printerbull Web-camerabull Device equipped with stepper motor for position-
ing of the spectrometric detectorbull Calibration device with reference sources
(Am-241 Co-60 Ba-133 Eu-152) for energy calibration
bull Removable collimators with end capbull Measurement proceduresbull ldquoClasterrdquo software
bull Measurement of gross alpha activity of alpha-emitting radionuclides
bull Measurement of alpha-emitting radionuclides activity in thin-layer samples meeting alpha-spectrometry requirements
Physical characteristicsDetectorbull Silicon ion-implanted 450 mm2
bull Easy to decontaminate thin windowbull dead layer less than 015 μmbull Background count rate in the range 3 divide 9 MeVbull No more than 09 h-1cm-2 for 450 mm2 detector
Energy rangebull 2 divide 9 MeVbull Lower limit of measurement range (minimum
detectable activity) 01 Bqbull Background count rate no more than 100 counts
in 24 hours
Electrical characteristics Power supplybull 220 V 50 Hz
Interfacebull USB
Complete setBasic complete setbull Detector unit with vacuum measuring chamber
and vacuum control systembull Low noise vacuum pump (type 2FY-05B or
equivalent)bull Check sourcebull ldquoProgressrdquo softwarebull Vacuum tube
MKS-01A ldquoMULTIRAD-ASrdquoALPHA SPECTROMETER
SPC ldquoDozardquoRadiation monitoring equipment
72 73
UCRV-2AIRFLOW MONITOR
bull Monitor of the air flow through filter of centralized multichannel sampling system
bull Radiation monitoring system (RMS) integration for internal exposures determination
bull Volume and flow rate measurements of the air that have passed through a analytical filter
bull Bar-code for filter identificationbull Operation as either standalone unit or as a part of
the RMS
Physical characteristicsMeasurement range of air volume bull 001 divide 9999 m3
Operation temperature range bull minus 20 divide +50 ordmС
Electrical characteristicsPower supply bull 220 V 50 Hz
Interface bull RS-485
PVP-06PORTABLE AIR SAMPLER
Air Sampler PVP-06 is indispensable for monitoring the radiation situation where the concentration of radioactive aerosols in the air does not require a sta-tionary sampling equipment Sampling head PVP-06 provides easy change of filters and cartridges
Purposebull To monitor the concentration of radioactive aero-
sols in the air sites
Controlled aerosolsbull Alpha- and beta-active aerosolsbull Daughter products of decay of radon and thoronbull Iodine isotopes
Physical characteristicsTypes of filtersbull Aerosol AFA-RSP-20bull Iodine AFA SI-20
Flow rate bull 33∙10-4 ndash 233∙10-4 m3s (20 divide 140 l min)
Electrical characteristicsPower supply bull 220 V50 Hzbull The vehicle power supply 108 divide 145 Vbull Internal battery
Minimal working time on internal battery to recharge bull 8 hours
Power consumption (at a flow rate of 100 lmin) bull 40 VA
Environment characteristicsOperating temperature bull minus 10 divide +40 deg C
Maximum humidity bull 90
Pressure bull 860 to 1060 hPA
Noise generated by the pump bull lt 55 dBA at 1 m
Mechanical characteristicsDimensions weight bull 241 times 108 times 160 mm 28 kg
Case material bull Plastic
Complete setbull Air sampler PVP-06bull AC power adapterbull Filters AFA-RSP-20 - 100 pcsbull Packaging for filters - 40 pcsbull Casebull Operation manualbull Calibration certificate
Optional equimpient bull Kit for sampling sorption columns of activated
carbon Ř head of sorption columns with protective
covers Ř activated charcoal SKT-3 - 1 pkg (02 L) Ř charocoal samples SC-13 - 8 pcs
bull Car charger bull Tipod bull Shoulder strapbull Calibration stand bull Filters AFA SI-20 - 100 pcs
Consumablesbull Aerosol filters AFA RSP-20bull Iodine filters AFA SI-20
SPC ldquoDozardquoRadiation monitoring equipment
74 75
Calibration of gamma dose and dose rate meters
Calibration ofbull Ambient equivalent dose H(10) meters (Sv Svh)bull Personal equivalent dose Hp(10) meters (Sv Svh)bull Exposure dose X meters (R Rh)bull Two sources in irradiator bull Select source and collimator opening using
tumbler
UPG-P DESKTOP GAMMA BEAM IRRADIATOR
Physical characteristicsRange of reproduced dose rate bull 05 μSvh divide 10 mSvh (50 μRh divide 100 mRh)
Sources activities bull 6times106 6times108 Bq (02 20 mCi) Cs-137
Overall dimensions bull 1250times400times300 mm
Irradiator weight bull Not more than 37 kg
Calibration bench weight bull Not more than 15 kg
Reference standards IEC 60846 IEC 61526
Physical characteristicsDetectorbull Silicon
Measurement range EEC measurement bull Measurement range of radon EEC
10 divide 10bull106 Bqbullm-3
bull Measurement range of thoron EEC 05 divide 10bull104 Bqbullm-3
bull Air flow through the filter 100plusmn05 lmin
Concentration measurementbull Measurement range of radon-222 concentration
in air 10 divide 20bull106 cpsbull Measurement range of 216Po(ThA)
1bull10-3 divide 1bull102 cpsbull Air sampler flow rate
10plusmn02 lminbull Measurement range of radon-222 concentration
in water samples 6 divide 800 Bqbullkg-1
bull Measurement range of radon-222 flux from soil surface 20 divide 103 mBqsbullm2
bull Measurement range of radon-222 concentration with preliminary sampling of air using air sam-plers 20 divide 107 Bqbullm-3
bull Measurement range of radon-222 concentration in samples of soil air 103 divide 106 Bqbullm-3
Operation temperature range bull 1 divide 35 ordmC
Electrical characteristicsPower supply bull 80 VA
Mechanical characteristicsOverall dimensions weight bull 220times200times165 mm 36 kg
ldquoALPHARAD PLUSrdquoRADON THORON amp THEIR PROGENY MONITORbull Measurement of radon and thoron concentration
and effective equivalent concentration (EEC)bull In the airbull In the indoor air of residential public and industri-
al buildings and structuresbull Measurement of radon in drinking water sourcesbull Measurements of radon flux from the soil surface
at land plots allocated for construction of houses public buildings and industrial facilities
bull Measurements of radon concentration in soil air
Reference standards IEC 61577
SPC ldquoDozardquoRadiation monitoring equipment
76 77
UKPN-2M-D NEUTRON BEAM IRRADIATOR
Reference standards IEC 61005 61322
Calibration of neutron dose and dose rate meters
Calibration ofbull Ambient equivalent dose H(10) meters (Sv Svh)bull Personal equivalent dose Hp(10) meters (Sv Svh)bull Flux density of neutrons (cm-2∙s-1)bull Transfer container for temporary storage of
sources bull Red light signal of source working position
Physical carachteristicsRange of reproduced dose ratebull 20 divide 800 μSvh
Range of reproduced flux densitiesbull 10 divide 400 cm-2∙s-1
Type of a source in use bull Pu-Be
Activity of a source in usebull 24х1011 Bq (with density of 107 s-1)
Overall dimensions weight no morebull 3000x750x2000 mm 300 kg
Required room dimensionsbull not less than 7x3x3 m
Electrical characteristicsPower supply bull 220 V 50 Hz
Calibration of gamma dose and dose rate meters
Calibration ofbull Ambient equivalent dose H(10) meters (Sv Svh)bull Personal equivalent dose Hp(10) meters (Sv Svh)bull Exposure dose X meters (R Rh)bull Four sources in irradiator bull Select source and move to working position
return to storage position using special rodbull Transfer container for temporary storage of
sources bull Red light signal of source working position
UPGD-2M-DGAMMA BEAM IRRADIATOR
Physical characteristicsRange of reproduced dose rate bull 05 μSvh divide 50 mSvh (50 μRh divide 5 Rh)
Maximum activity of source bull 2times1011 Bq (50 Ci) Cs-137
Overall dimensionsbull Irradiator 800times500times500 mmbull Guide rails length 30 mbull Height 16 mbull Weight not more than 700 kgbull Required room dimensions not less than 7x3x3 m
Electrical characteristicsPower supply bull 220 V 50 Hz
UPGD-2M-D
Reference standards IEC 60846 IEC 61526 IEC 61066
SPC ldquoDozardquo
78 79
Contents
MEASURING UNITS
DBG-S11D wide range gamma area monitor 40
UDKS-100 gamma and X-ray area monitor 41
UDMN-100 neutron area monitor 41
ALARM UNITS
BAS-2 ldquoMICROrdquo external visual alarm 42
BZS-2 ldquoMicrordquo external audible alarm 42
Illuminated warning signs 43
ldquoImpulsrdquo external display unit 43
UIM-3D area monitor count rate meter 44
DKG-05D personal gamma dosimeter 46
DVS-02D gamma-neutron personal electronic dosimeter 47
DVGI-8D new pen-type personal ionization chamber dosimeters 48
DKG-02U ldquoARBITERrdquo wide range gamma-dosimeter 49
DKG-07D ldquoDROZDrdquo gamma-dosimeter 50
MKS-15D ldquoSNEGIRrdquo multi ndash purpose radiation survey meter 51
SRPS-05D gamma monitor 52
DOZA-TLD multipurpose TLD system 53
DKS-96 universal radiation survey meter 54
EXTERNAL PROBES ALPHA
Alpha BDZA-96 55
Alpha BDZA-96B 55
Alpha BDZA-96M 55
Alpha BDZA-96S 55
Alpha BDZA-96T 55
EXTERNAL PROBES BETA
Beta BDZB-96 56
Beta BDZB-99 56
Beta BDZB-96B 56
Beta BDZB-96S 56
EXTERNAL PROBES GAMMA
Gamma BDKS-96B 57
Gamma and beta BDKS-96S 57
Gamma BDMG-96 57
EXTERNAL PROBES GAMMA
Gamma-search BDVG-96 58
Gamma-search BDPG-96 58
ContentsRadiation monitoring systemldquoPELIKANrdquo Radiation monitoring system (RMS) 6
BDMG-101 high range gamma area monitor 10
DBG-S11D wide range gamma area monitor 11
BDRG-52 high range gamma area monitor for accident and post-accident conditions 12
UDGP-01 Liquid technological environments monitor 13
UDMN-100 neutron area monitor 14
UDKG-100 Wel Liquid gamma monitor 14
BOP-1M data processing and transmission unit 15
UDA-1AB particulate monitor 16
UDG-1B noble gas monitor 17
UDG-03D noble gas monitor 18
UDI-1B iodine monitor 19
UDGB-01 noble gasesH-3C-14 monitor 20
UDGP-01 steam generator leakage monitor 21
UPPVM air flow parameters monitor 22
ldquoIMPULSrdquo external display unit 23
BI-2 remote display amp alarm unit 24
BASBAS-1s external alarm 25
SKGAV stack monitor 26
RMS software 28
RMS workstation ndash operator console 29
Configurator software 29
RM RACK radiation monitoring rack 30
SRKS-01D criticality accident alarm system 32
ldquoATLANT-Mrdquo environmental radiation monitoring system 34
ldquoBREEZErdquo high-volume air sampler 35
ldquoGAMMA-SENSORrdquo gamma-survey system 36
Radiation monitoring equipmentAREA MONITOR ldquoFREGATrdquo 38
BPI-1D local display unit 39
80
Gamma-search BDPG-96M 58
Gamma BDKG-96 stainless steel casing for geologic applications well logging 59
EXTERNAL PROBES NEUTRON
Neutron BDMN-96 59
Neutron-search BDKN-96 59
RZB-05D Hand-foot-clothing monitor 60
RZBA-04-04M whole body contamination monitor 61
RZA-05D alpha hand-monitor 62
UMF-2000 low level alpha- beta- counter 63
DRK dose area product meter 64
ldquoPROGRESS-BETArdquo scintillation beta spectrometer 65
ldquoPROGRESS-GAMMArdquo scintillation gamma spectrometer 66
ldquoPROGRESS-G(P)rdquo portable scintillation gamma spectrometer 67
ldquoPROGRESS-ARrdquo alpha radiometer 68
ldquoPROGRESSrdquo whole body counter 69
MKG-01D ldquoSADOVNIKrdquo spectrometry system 70
MKS-01A ldquoMULTIRAD-ASrdquo alpha spectrometer 71
UCRV-2 airflow monitor 72
PVP-06 portable air sampler 73
ldquoALPHARAD PLUSrdquo radon thoron amp their progeny monitor 74
UPG-P desktop gamma beam irradiator 75
UPGD-2M-D gamma beam irradiator 76
UKPN-2M-D neutron beam irradiator 77
Radiation monitoring system SPC ldquoDozardquo
32 33Reference standards IEC 60860 ANSIANS-83 ISO 7753
Purposebull Detection and recording of criticality accident
(CA) by measuring the absorbed dose rate of gamma-neutron radiation in the premises of monitored object its comparison with a threshold value and generation of audible and visual signals
bull Automatic collection processing storage and display of measurement data and related infor-mation as visual and graphical representation for operators of nuclear safety service
Functions of the systembull Detection and recording of CA events by con-
tinuous measurement of absorbed dose rate of gamma radiation comparison of measured values with preset thresholds generation of signals to activate the alarm
bull Activation of audible visual alarmbull In the event of CA turning on warning signals
ldquoDO NOT ENTERrdquo at illuminated information pan-els placed at the entrances to the controlled area
Featuresbull Data can be transferred to external data commu-
nication channel using RS-485 interface (DiBus data exchange protocol)
bull Automatic self-testing of detection units BR-04D with display of information about the type of fault
bull Possibility for connecting additional a detection and alarm units
bull Ability to function in general regardless of the functioning of components within the agreed scope of nuclear safety tasks
bull Radiation hardness up to 100 Gy
SRKS-01DCRITICALITY ACCIDENT ALARM SYSTEM
Features of softwarebull Collection of information via RS-485 network
displaying it on the PC monitor transmission to remote users archiving and storage
bull Status monitoring and display of values measured by BR-04D and DBG-S11D in locations as per layout of premises
bull Access to archived data with possibility to gener-ate reports for periods determined by operator
bull Maintenance and archiving of a log of dosimetric measurements data and events along with their time stamps
bull Possibility to transfer data to external users via Ethernet network for integrating of CA into higher level systems
Basic complete setLower level bull Control unit with power supplybull BR-04D detection unitsbull BZS-01D audible alarm unitsbull BSS-01D visual alarm unitsbull SIT-01D illuminated warning signsbull PBZ panels for muting audible alarmbull Network communication module
Additional lower layer devicesbull DBG-S11D wide range gamma area monitor
Upper layer bull CDP central display panelbull Service workstation
RS-485
RS-485
RS-4
85
Audible alarm units BZS-01D
Illuminated warning signs SIT-01D
Detection units BR-04D
Network communication
moduleDBG-S11D wide range gamma area monitor
Panels for muting audible alarm
Control unit with power supply
Visual alarm units BSS-01D
RS-485
RS-485
RS-4
85
Audible alarm units BZS-01D
Illuminated warning signs SIT-01D
Detection units BR-04D
Network communication
moduleDBG-S11D wide range gamma area monitor
Panels for muting audible alarm
Control unit with pow-er supply
Visual alarm units BSS-01D
RS-485
RS-4
85
Audible alarm units BZS-01D
Illuminated warning signs SIT-01D
Detection units BR-04D
Network communication
moduleDBG-S11D wide range gamma area monitor
Panels for muting audible alarm
Control unit with power supply
Visual alarm units BSS-01D
RS-485
RS-485
RS-4
85
Audible alarm units BZS-01D
Illuminated warning signs SIT-01D
Detection units BR-04D
Network communication
moduleDBG-S11D wide range gamma area monitor
Panels for muting audible alarm
Control unit with power supply
Visual alarm units BSS-01D
Ethernet
Central display panel Service workstation
RS-485
RS-485
RS-4
85
BZS-01D audible alarm units
SIT-01D illuminated warning signs
BR-04D detection units
Network communication
moduleDBG-S11D wide range gamma area monitor
PBZ panels for muting audible alarm
Control unit with power supply
BSS-01D visual alarm units
Radiation monitoring system SPC ldquoDozardquo
34 35
ldquoBREEZErdquoHIGH-VOLUME AIR SAMPLER
Physical characteristicsbull Measurement range of air flow rate
250 divide 1200 m3hbull Continuous operation time not less than 24 h
Filter materialsbull High-purity glass fiberbull Pure quartz or cellulosebull Filter fabric FPP-15-15
Electrical characteristicsPower supply bull 220380 V 50 Hz
Interfaces bull RS-485bull Ethernetbull GSMGPRS (option)
Environmental characteristicsTemperature range bull minus 40 divide + 40 ordmC
Relative humidity limit at 35 ordmC bull 95
Atmospheric pressure range bull 840 divide 1067 kPa
Versionsbull Standalone unit bull Part of Environmental Radiation Monitoring
System (ERMS)
Type of detection unitsbull Beta block BDZB-100Lbull DBG-S11D wide range gamma area monitorbull Scintillation spectrometric block
The motor of Air Sampler is controlled by an electronic flow sensor that detects changes in the operators pre-set flow rate caused by changes in temperature barometric pressure and pressure drop due to dust loading on filter media It compensates for these changes by adjusting the motor speed to maintain the pre-set flow ratebull Measurement of parameters of ionizing radiation bull Standalone mode of operation or as the part
of Environmental Radiation Monitoring System (ERMS)
Purposebull Environmental Radiation Monitoring System
(ERMS) in the control and buffer areas of the radia-tion and nuclear facilities
Referencesbull Since the year 2000 the system is successfully
operating the ERMSs at 8 Russian nuclear power plants (about 180 monitoring stations)
bull Since the year 2005 the ERMS is operating in the Moscow (about 40 monitoring stations)
bull Since the year 2005 the regional ERMS is under operation in several Russian Federation regions
Basic complete setMonitoring stations bull Data processing and transmission unit BOP-1TA bull Gamma area monitor DBG-S11D
Central data processing station (CDPS)bull Data processing and transmission unit BOP-1TAbull Server
By requestbull Emergency Response and Crisis Management
Centers for enterprisesbull Regional Emergency Response and Crisis Manage-
ment Centersbull rdquoBreezerdquo High-Volume Air Samplerbull Mobile lab with gamma-survey system rdquoGammandash
sensorrdquo
ldquoATLANT-MrdquoENVIRONMENTAL RADIATION MONITORING SYSTEM
Monitoring system for the continuous radiation monitoring of territories and facilities with the data transmission GSMGPRS network
Data transmission bull GSMGPRS
Power supply bull 220 V 50 Hz
Continuous autonomous operation (at 20 ordmC)bull From built-in battery not less than 5 hoursbull From external battery not less than 24 hours
Operation temperature bull Minus 40 divide +50 ordmC
Operation humidity bull Up to 98
Protection bull IP65
Reference standards Nuclear IEC 61017-11991 IEC 61017-21994
36
Radiation Monitoring Equipment
bull Localization of radioactive contaminationsbull Database with dose rate contaminations
spectra measurement date amp time coordi-nates
bull Work as part of mobile laboratory or as part of Environmental Radiation Monitoring System with real-time data transfer
Physical characteristicsDetector bull Scintillation NaI (Tl) GM counters
Measurement rangebull 01 ndash 107 μSvh
Energy range bull 005 ndash 3 MeV
Operation temperature range bull minus 10 divide +50 ordmС
Electrical characteristics bull Power supply 220 V 50 Hz
ldquoGAMMAndashSENSORrdquoGAMMA-SURVEY SYSTEM
SPC ldquoDozardquoRadiation monitoring equipment
38 39
AREA MONITOR ldquoFREGATrdquoArea Monitor ldquoFregatrdquo is designed for building rela-tively simple and inexpensive radiation monitoring systems at such facilities as radionuclide sources storage areas isotope products warehouses nuclear medicine departments PET centers calibration laboratories where sources of ionizing radiation are used etc
Small scale automated radiation monitoring systems built with ldquoFregatrdquo components featuring audible and visual alarms are matched suitable to meet the regulatory radiation safety requirements
Area monitor ldquoFregatrdquo requires virtually no adjust-ment it is simple and convenient for installation and operation
BPI-1D LOCAL DISPLAY UNIT
Display of monitored parameters values received from external measuring devices
Purposebull Processing and display of values of monitored
parameters on information panel bull Comparison of values of monitored parameters
with thresholdsbull Transfer of monitored parametersrsquo values to
networkbull Generation of alarm in case of exceeding of preset
thresholds including external alarm devices
FeaturesTesting the unit and connected devicesbull Visually on the panelbull Using adjustment software when connected to
PC via USB
Automatic self-testing
The panel displays the following informationbull Diagnostic information about the status of con-
nected devicesbull Current date and timebull Values of measured parametersbull Position of measured values with respect to the
thresholds in the form of scales with green yellow and red zones
bull Time history (trend) for each measured value
Physical characteristicsTemperature range bull minus 10 divide + 50 ordmC
Maximum number of connected devicesbull measuring devices 15bull external audible and visual alarm 15
Display diagonal bull 152 cm (6)
Electrical characteristicsbull Interfaces RS-485bull Power supply 220 V 50 Hz 12 divide 24 V
Mechanical characteristicsbull Protection index IP54bull Paint decontaminable
Overall dimensions weightbull 296x248x118 mm 5 kg
DBG-S11D wide range gamma area monitor
UDMN-100 neutron area monitor
Ethernet RS-485
UDKS-100 gamma and X-ray area monitor
BPI-1D Local display unit
BAS-2 ldquoMicrordquo external visual alarm
BZS-2 ldquoMicrordquo external audible alarm
ldquoImpulsrdquo external display unit
Service workstation
Illuminated warning signs
SPC ldquoDozardquoRadiation monitoring equipment
4140
Continuous automatic monitoring of the gamma- X-ray ambient dose equivalent rate
Physical characteristicsbull Detector tissue-equivalent plastic scintillator
Oslash 45times20 mm
Measurement range bull Dose rate measurement range 01 μSvh divide 1 Svh bull Energy range 0015 divide 10 MeV
Mechanical characteristicsbull Protection index IP65bull Paint decontaminable
Overall dimensions weightbull Oslash72times265 mm 15 kg
UDKS-100 GAMMA AND X-RAY AREA MONITOR
UDMN-100 NEUTRON AREA MONITOR
Physical characteristicsbull detector ndash scintillator ZnS(Ag) Li-6
Measurement range bull 01 μSvh divide 01 Svh
Energy range bull 0025 eV divide 100 MeV
Temperature range bull minus 45 divide +50 ordmC
Electrical characteristicsbull Interfaces RS-485
Mechanical characteristicsbull Protection index IP 65bull Paint decontaminable
Overall dimensions weight bull 428times258times347 mm 115 kg
Continuous automatic monitoring of the neutron-radiations ambient dose equivalent ratebull Spherical polyethylene moderator Oslash 239 mm
MEASURING UNITS
DBG-S11D WIDE RANGE GAMMA AREA MONITOR
Continuous automatic monitoring of the gamma- ambient dose equivalent rate
Physical characteristicsbull Detector ndash GM counters
Measurement rangebull DBG-S11D 01 μSvh divide 10 mSvhbull DBG-S11D-01 01 μSvh divide 10 Svhbull DBG-S11D-02 01 μSvh divide 100 Svh
Energy rangebull 005 divide 30 MeV
Temperature range bull minus 40 divide +50 ordmC
Electrical characteristicsbull Interfaces RS-485 USB
Mechanical characteristicsbull Protection index IP 68bull Paint decontaminable
Overall dimensions weightbull DBG-S11D Oslash 68times141 mm 065 kg bull DBG-S11D-01 Oslash 68times179 mm 07 kgbull DBG-S11D-02 Oslash 68times179 mm 07 kg
Versionsbull DBG-S11Dbull DBG-S11D-01bull DBG-S11D-02
Reference standards Nuclear IEC 60846 IEC 60532 EMC IEC 61010 IEC 61000-6-2 Seismic IEC 60980
SPC ldquoDozardquoRadiation monitoring equipment
4342
ALARM UNITS
Generation visual signals of the excess of preset thresholds
Physical characteristicsLength of communication cablebull up to 1200 mbull Alarm Visual alarm green yellow red
Electrical characteristicsbull Power supply +12 V
Mechanical characteristicsbull Protection index IP 23
Overall dimensions weight 160times84times41 mm 02 kg
BAS-2 ldquoMICROrdquo EXTERNAL VISUAL ALARM
Generation audible signals of the excess of preset thresholds
Physical characteristicsLength of communication cablebull up to 1200 mbull Audible alarm 80 divide 100 dB at a distance of 1 m
Electrical characteristicsbull Power supply +12 V
Mechanical characteristicsbull Protection index IP 23
Overall dimensions weight 160times84times41 mm 02 kg
BZS-2 ldquoMICROrdquo EXTERNAL AUDIBLE ALARM
Physical characteristicsLength of communication cablebull up to 1200 m
Electrical characteristicsbull Power supply 220 V 50 Hz
Mechanical characteristicsbull Protection index IP 23
Overall dimensions weight bull 330times110times20 mm 05 kg
Physical characteristicsLength of communication cablebull up to 1200 m
Character height bull ldquoImpuls-910-Rrdquo 100 mmbull ldquoImpuls-915-D4Srdquo 150 mmbull ldquoImpuls-927-D4Srdquo 270 mm
Operating temperature rangebull ldquoImpuls-910-Rrdquo 0 divide +50 degCbull ldquoImpuls-915-D4Srdquo ldquo-727-D4Srdquo minus 40 divide +50 degC
Electrical characteristicsbull Power supply 220 V 50 Hz
Mechanical characteristicsProtection index bull ldquoImpuls-910-R IP 44bull ldquoImpuls-915-D4Srdquo ldquo-727-D4Srdquo IP 65
Overall dimensions weight bull ldquoImpuls-910-Rrdquo 400times160times60 mm 3 kgbull ldquoImpuls-915-D4Srdquo 815times250times80 mm 5 kgbull ldquoImpuls-927-D4Srdquo 1250times330times80 mm 5 kg
ILLUMINATED WARNING SIGNS
ldquoIMPULSrdquo EXTERNAL DISPLAY UNIT
SPC ldquoDozardquoRadiation monitoring equipment
4544
Individual threshold setting for each measurement channel
Continuous area and process monitoring
Collect amp display data from two measurement chan-nels (units with RS-485 or analog pulses)
Audible and visual alarms on exceeding preset thresholds or status of connected devices
Individual threshold setting for each measurement channel
Switching on the external alarm or executive devices when any threshold is exceeded
The wide panel displays the following information bull Values of measured parameters as min-1∙cm-2
s-1∙cm-2 μSvhbull Diagnostic information about the status of con-
nected devicesbull Current date and timebull Position of measured values with respect to the
thresholds in the form of scales with green yellow and red zones
bull Time history (trend) for each measured value
Physical characteristics Measurement range bull Count rate up to 107 CPM (170 kHz)
Operating temperature range bull minus 20 divide +50 ordmC
Electrical characteristics bull Power supply 220 V bull Interfaces USB
Mechanical characteristics bull Protection index IP 65 bull Overall dimensions weight 222times164times73 mm
40 kg
UIM-3D AREA MONITOR COUNT RATE METER
Measurement of alpha radiation flux density
Detector unit BDZA-100 (70 cm2) Measurement range 01 divide 104 min-1∙cm-2
Detector unit BDZA-100B (300 cm2) Measurement range 01 divide 2103 min-1∙cm-2
Measurement of beta radiation flux density
Detector unit BDZB-100 (28 cm2) Measurement range 10 divide 105 min-1∙cm-2
Detector unit BDZB-100L (30 cm2) Measurement range 10 divide 104 min-1∙cm-2
Detector unit BDZB-11D (84 cm2) Measurement range 5 divide 15∙104 min-1∙m-2
OPTIONAL PROBESMeasurement of gamma radiation flux density
Detector units BDEG-03 Measurement range 4 divide 2000 s-1∙cm-2
Detector unit UDKG-100 for operation in the rocks ore liquid media and sludge Measurement range 40 divide 8000 s-1∙cm-2
Measurement of the ambient dose equivalent rate
Detector unit DBG-S11D Measurement range 01 μSvh divide 100 Svh
Measurement of neutron radiation ambient dose equivalent rate
Detector unit BDMN-100 Measurement range 01 μSvh divide 01 Svh
SPC ldquoDozardquoRadiation monitoring equipment
46 47Reference standards Nuclear IEC 61526
Measurement of gamma-radiation personal dose equivalent Hp(10)bull Stand-alone dosimeter or composed of dosimetric
system onebull Audible and visual alarmbull Large memory dose accumulation historiesbull Exclusion of unauthorized intervention in dosim-
etry operation
DKG-05D PERSONAL GAMMA DOSIMETER
Physical characteristicsDetectors bull Silicon
Measurement range bull Dose rate 1 μSvh divide 10 Svhbull Dose 01 μSv divide 15 Sv
Energy range bull 005 divide 30 MeV
Electrical characteristicsbull Power supply rechargeable NiMH battery 1
alcaline battery (type AAA)
Operation timebull Till recharging not less 400 hoursbull With one set batteries not less 1000 hours
Mechanical characteristicsOverall dimensions weight bull 47times26times87 mm (with clip) 70 g
Environmental characteristicsbull IP65bull Temperature range minus 20 divide +45 ordmCbull Humidity up to 98 at 35 ordmCbull Shock vibration and drop resistant
Alarmbull Excess of alarm thresholdsbull Warnings of self-test failure and battery discharge bull Audible alarm 80 dB at 40 cmbull Visual alarm blinking LED
Relative equipmentbull One dosimeter charger ZU-1Mbull Chargestorage cassetes KZU-28KZU-56bull ldquoSmart chargingrdquo feature extends battery life timebull DKG-05D reader US-05bull DKG-05D system reader DVS-01D
Reader-PC interfacebull US-05 USB bull DVS-01D Ethernet
KZU-28
Physical characteristicsDetectors bull Silicon Li-6
Gamma measurement range bull Dose rate 1 μSvh divide 10 Svhbull Dose 01 μSv divide 15 Sv
Gamma energy range bull 005 divide 60 MeV
Neutron measurement range bull Dose rate 1 μSvh divide 2 Svhbull Dose 20 μSv divide 15 Sv
Neutron energy range bull 0025 eV divide 20 MeV
Electrical characteristicsPower supply bull Rechargeable NiMH batterybull Operatiion time till recharging not less 200 hours
Mechanical characteristicsOverall dimensions weight bull 47times26times87 mm (with clip) 70 g
Environmental characteristicsbull IP65bull Temperature range minus 20 divide +40 ordmCbull Humidity up to 75 at 30 ordmCbull Shock vibration and drop resistant
Alarmbull Excess of alarm thresholds bull Warnings of self-test failure and battery discharge bull Audible alarm 80 dB at 40 cmbull Visual alarm blinking LED
Relative equipmentbull One dosimeter charger ZU-1Mbull Chargestorage cassetes KZU-28 KZU-56bull ldquoSmart chargingrdquo feature extends battery life timebull DVS-02D reader UZS-01Sbull DVS-02D system reader DVS-01D
Reader-PC interfacebull UZS-01S USB bull DVS-01D Ethernet
UZS-01DReference standards Nuclear IEC 61526
DVS-02D GAMMA-NEUTRON PERSONAL ELECTRONIC DOSIMETER
Measurement of gamma- and neutron radiations personal dose equivalent Hp(10)bull Stand-alone dosimeter or composed of dosimetric
system onebull Audible and visual alarmbull Large memory dose accumulation historiesbull Exclusion of unauthorized intervention in dosim-
etry operationbull Both albedo thermal neutrons and intermediate
fast neutrons registrationbull Usable in the fields of Pu(Be) Po(Be) Cf and other
neutron sources as well as near nuclear reactors without neutron spectrum estimation
SPC ldquoDozardquoRadiation monitoring equipment
48 49
Dosimeters DVG-03D
DVGI-8D NEW PEN-TYPE PERSONAL IONIZATION CHAMBER DOSIMETERS
Measurement of personal dose equivalent Hp(10) of gamma and X-ray radiationbull Hp(10) of continuous and pulsed gamma and
X-ray radiation bull Electronic reader KSU-1bull Dosimeter DVG-03D with electronic ID bull Personal dose histories in the readerrsquos memorybull Readerrsquos connection with PC for database main-
tenance
Physical characteristicsDetector bull Ionization chamber
Measurement range bull 001 mSv divide 25 mSv
Energy range bull 0015 divide 25 MeV
Temperature range bull Reader KSU-1 +10 divide +50 ordmСbull Dosimeter DVG-03D minus 40 divide +50 ordmС
Electrical characteristicsPower supply bull Reader KSU-1 220 V 50 Hz built-in batteries bull Dosimeter DVG-03D four batteries CR 1025 bull Batteries life 3 yearsbull Readers interfaces RS-232USB 20
Mechanical characteristicsOverall dimensions weightbull Dosimeter DVG-03D Oslash 18times126 mm 005 kgbull Reader KSU-1 235times232times125 mm 28 kg
Reference standards Nuclear IEC 62387-1
DKG-02U ldquoARBITERrdquo WIDE RANGE GAMMA-DOSIMETER
Physical characteristicsDetectors bull GM counters
Measurement rangebull Dose-rate 01 μSvh divide 3 Svhbull Dose 1 μSv divide 100 Sv
Energy range bull 005 divide 3 MeV
Electrical characteristicsbull Power supply 2 alcaline batteries (type AA)bull Batteries life not less 200 hours
Mechanical characteristicsOverall dimensions weight bull 152times82times32 mm 03 kg
Environmental characteristicsbull Temperature range minus 20 divide +50 ordmCbull Humidity up to 90 at +25 ordmCbull Shock vibration and drop resistant
Reference standards Nuclear IEC 60846
Measurement of gamma radiation ambient equiva-lent dose H(10) and dose rate H(10)bull Audible signals (clicks) for radiation condition
estimationbull Analog scale for search modebull Audible and visual alarms of the excess of preset
dose and dose rate thresholds bull Shock-resistant water-proof easy decontamina-
tion casebull 100 measurement results memory with date and
time of measurementbull Indication of total dose accumulated during
exploitation time bull Indication of measurement result statistical
uncertainty
SPC ldquoDozardquoRadiation monitoring equipment
50 51
Physical characteristicsDetectors bull GM counter
Measurement rangebull Dose-rate 01 μSvh divide 3 mSvhbull Dose 1 μSv divide 02 Sv
Energy range bull 005 divide 3 MeV
Temperature range bull Minus 20 divide +50 ordmC
Electrical characteristicsbull Power supply 2 alcaline batteries 15 V (type AA)bull Batteries life not less 200 hours
Mechanical characteristicsOverall dimensions weight bull 122times74times29 mm 025 kg
Reference standards Nuclear IEC 60846
DKG-07D ldquoDROZDrdquoGAMMA-DOSIMETER
Measurement of gamma radiation ambient equiva-lent dose H(10) and dose rate H(10)bull Two independent measurement channels dose
and dose ratebull Audible signals (clicks) for radiation condition
estimationbull Continuous measurement with updating meas-
urement resultbull Measurement result can be obtained with any
desired statistical uncertainty (error)bull Automatic restart when radiation level sharply
changesbull Indication of statistical uncertainty (error) during
measurement process
Continuous measurement with updating measure-ment result
Automatic restart when radiation level sharply changes bull Gamma dose H(10) and dose-rate H(10) meas-
urementbull Beta and gamma contamination surveybull Indication of statistical uncertainty during the
measurementbull Continuous measurement with accuracy increas-
ing with time bull Automatic restart triggered by change of gamma
dose-ratebull Compensation of gamma count rate while meas-
uring beta radiationbull Indication of battery charge levelbull Audible signal of the excess of preset threshold
Physical characteristicsDetectors bull GM counter
Measurement range bull Dose-rate 01 microSvh divide 20 mSvhbull Dose 1 microSv divide 100 Svbull Beta flux density (for Sr-90+Y-90)
10 divide 105 cm-2 min-1
Energy range bull Gamma 005 divide 3 MeVbull Beta 01 divide 3 MeV
Temperature range bull Minus 20 divide +50 ordmC
MKS-15D ldquoSnegirrdquo backside
MKS-15D ldquoSNEGIRrdquoMULTI ndash PURPOSE RADIATION SURVEY METER
Reference standards Nuclear IEC 60846 IEC 60325
Electrical characteristicsbull Power supply 2 alcaline batteries (type AA)bull Battery life not less 400 hours
Mechanical characteristicsOverall dimensions weight bull 124times72times35 mm 035 kg
SPC ldquoDozardquoRadiation monitoring equipment
52 53
Physical characteristicsDetectorbull GM counter
Measurement range bull 01 μSvh divide 20 mSvh
Energy range bull 005 divide 30 MeV
Threshold setting range bull 03 μSvh divide 20 mSvh
Step change of the thresholdbull In the range 03 divide 10 μSvh with the step
001 μSvhbull In the range 10 divide 100 μSvh with the step
01 μSvhbull In the range 100 divide 2000 μSvh with the step
10 μSvh
Electrical characteristicsPower supply bull 220 V 50 Hz bull Relay output
Mechanical characteristicsProtection index bull IP 40
Overall dimensions weight bull 226times120times75 mm 07 kg
Alarmbull Sound alarm 80 divide 100 dBA at distance 1 mbull Visual alarm redbull Connection of the external alarm signaling unit
Reference standards Nuclear IEC 60846 IEC 60532
Continuous automatic monitoring of the ambient dose equivalent rate bull Measurement of gamma dose rate H(10)bull Audible and visual alarm signals for preset
thresholdsbull Switching on the external signaling or executive
devices
SRPS-05D GAMMA MONITOR
Measurement ofbull Gamma and X-ray personal dose equivalent
Hp(10)bull Neutron personal dose equivalent Hp(10)bull Lens dose equivalent Hp(3)bull Skin dose equivalent Hp(007)bull TLD reader day-to-day tests using built-in LEDbull No needs nitrogen for heating
Physical charachteristicsDetectors bull 7LiF Mg Ti (gamma beta)bull 6LiF Mg Ti (neutron)
Gamma and X-ray Hp(10) Measurement range bull 500 μSv divide 10 Sv
Energy range bull 0015 divide 30 MeV
Neutron Hp(10)Measurement range bull 01 mSv divide 100 mSv
Energy range bull 0025 eV divide 10 MeV
Beta and photons Hp(007) Hp(3) Measurement range bull 2 mSv divide 100 Sv
Energy range bull Beta 025 divide 35 MeVbull Photons lt15 keV
Mechanical characteristicsDosimeters overall dimensions weight bull Gamma Hp(10) DTL-2 holder - 62times26times16 mm
16 gbull DTU holder - 42times28times18 mm 8 gbull Lens Hp(3) face skin Hp(007) Oslash 32times16 mm 9 gbull Finger skin Hp(007) 90times20times2 mm 1 gbull Neutron gamma Hp(10) 48times40times20 mm 30 g
Reference standards Nuclear IEC 61066
DTL-2 DTU-2
MKD (A-type) DVNG-M
DOZA-TLD MULTIPURPOSE TLD SYSTEM
SPC ldquoDozardquoRadiation monitoring equipment
54 55
Continuous and pulsed gamma and X-ray dose H(10) and dose-rate measurementbull Alpha beta and gamma contamination surveybull Neutron dose H(10) and dose-rate measurementbull Gamma radiation flux density in boreholes and
liquid media measurement
Electrical characteristicsPower supply bull UIK-05 four C-size batteriesbull UIK-05-01 rechargeable batterybull UIK-06 rechargeable battery
Interfaces bull RS-232bull USB (via adapter)
bull Detector type automatic determination and corre-sponding measurement modes selection
bull Alarm threshold settings ndash for dose dose-rate alpha and beta contaminations
bull ldquoDetectrdquo and ldquoLocaterdquo modes for survey probes
Reference standards Nuclear IEC 60846 IEC 60325 IEC 61005 IEC 62363
Case
UIK-06 control unit165times78times48 mm 03 kg
DKS-96UNIVERSAL RADIATION SURVEY METER
UIK-05 control unit202times86times90 mm 10 kg
BDZA-96
BDZA-96B
BDZA-96M
BDZA-96S
BDZA-96T
EXTERNAL PROBES ALPHAALPHA BDZA-96Detector bull ZnS(Ag) 70 cm2
Measurement range (for Pu-239)bull 01 divide 104 min-1cm-2
Overall dimensions weightbull Oslash 130times240 mm 11 kg
ALPHA BDZA-96BDetector bull ZnS(Ag) 300 сm2
Measurement range (for Pu-239)bull 01 divide 2103 min-1cm-2
Overall dimensions weightbull Oslash 230times290 mm 40 kg
ALPHA BDZA-96MDetector bull ZnS(Ag) 10 сm2
Measurement range (for Pu-239)bull 01 divide 105 min-1cm-2
Overall dimensions weightbull Oslash 65times240 mm 09 kg
ALPHA BDZA-96SDetector bull ZnS(Ag) 30 сm2
Measurement range (for Pu-239)bull 01 divide 5104 min-1cm-2
Overall dimensions weightbull Oslash 90times240 mm 10 kg
ALPHA BDZA-96TDetector bull Silicon 5 сm2
Measurement range (for Pu-239)bull 01 divide 106 min-1cm-2
Overall dimensions weightbull Oslash 50times60 mm 015 kg
SPC ldquoDozardquoRadiation monitoring equipment
56 57
BETA BDZB-96Detector Scintillator 28 сm2
Measurement range (for Sr-90+Y-90)bull 10 divide 105 min-1cm-2
Energy rangebull 03 divide 30 MeV
Overall dimensions weightbull Oslash 90times230 mm 09 kg
BETA BDZB-99Detector bull GM counter 30 сm2
Measurement range (for Sr-90+Y-90)bull 20 divide 104 min-1см-2
Energy rangebull 012 divide 30 MeV
Overall dimensions weightbull Oslash 88times80 mm 04 kgbull Telescopic pole length 07 m
BETA BDZB-96BDetector bull GM counter 80 сm2
Measurement range (for Sr-90+Y-90)bull 3 divide 104 min-1сm-2
Energy rangebull 012 divide 30 MeV
Overall dimensions weightbull 150times200times110 mm 15 kg
BETA BDZB-96Sbull Detector GM counter 15 сm2
Measurement range (for Sr-90+Y-90)bull 10 divide 3104 min-1cm-2
Energy rangebull 012 divide 30 MeV
Overall dimensions weightbull Oslash 65times65 mm 03 kgbull Telescopic pole length 07 m
BDZB-96
BDZB-99
BDZB-96B
BDZB-96S
EXTERNAL PROBES BETA
GAMMA BDKS-96BDetector bull Tissue-equivalent scintillator Oslash 45times20 mm
Measurement rangebull Dose rate H(10) 01 μSvh divide 1 Svhbull Dose H(10) 01 μSv divide 10 Sv
Energy rangebull 0015 divide 10 MeV
Overall dimensions weightbull Oslash 60times250 mm 085 kg
GAMMA AND BETA BDKS-96SDetector bull Double GM counters
Measurement rangebull Gamma dose rate H(10) 01 μSvh divide 1 mSvhbull Gamma dose H(10) 01 μSv divide 10 Svbull Beta 10 divide 3104 min-1cm-2
Energy rangebull Gamma 005 divide 3 MeVbull Beta 012 divide 3 MeV
Overall dimensions weightbull Oslash 80times80 mm 035 kgbull Telescopic pole length 07 m
GAMMA BDMG-96Detector bull GM counters
Measurement rangebull Dose rate H(10) 01 μSvh divide 10 Svhbull Dose H(10) 01 μSv divide 10 Sv
Energy range bull 005 divide 3 MeV
Overall dimensions weightbull 40times250 mm 05 kgbull Telescopic pole length 07 m 4 m (by request)
EXTERNAL PROBES GAMMA
BDKS-96B
BDMG-96
BDKS-96S
SPC ldquoDozardquoRadiation monitoring equipment
58 59
GAMMA-SEARCH BDVG-96Detector bull Scintillator NaI(Tl) Oslash 63times63 mm
Measurement rangebull Flux density measurement range 4 divide 2000 s-1cm-2
bull Dose rate H(10) for Cs-137 01 divide 30 μSvhbull Sensitivity for Cs-137 3000 (pulsess-1)( μSvh-1)
Overall dimensions weightbull Oslash 88times400 mm 20 kgbull Modular pole length 16 m
GAMMA-SEARCH BDPG-96Detector bull Scintillator NaI(Tl) Oslash 25times40 mm
Measurement rangebull Flux density measurement range 10 divide 8000 s-1cm-2
bull Dose rate H(10) for Cs-137 01 divide 100 μSvhbull Sensitivity for Cs-137 500 (pulsess-1)( μSvh-1)
Overall dimensions weightbull 50times190times480 mm 10 kgbull Telescopic pole length 07 m
GAMMA-SEARCH BDPG-96MDetector bull Scintillator NaI(Tl) Oslash 18times30 mm
Measurement rangebull Flux density measurement range 10 divide 24000 s-1cm-2
bull Dose rate H(10) for Cs-137 01 divide 300 μSvhbull Sensitivity for Cs-137 200 (pulsess-1)( μSvh-1)
Overall dimensions weightbull Oslash 35times320 mm 05 kgbull Telescopic pole length 07 or 38 m
EXTERNAL PROBES GAMMA
BDVG-96
BDPG-96M
BDPG-96
EXTERNAL PROBESGAMMA BDKG-96 STAINLESS STEEL CASING FOR GEOLOGIC APPLICATIONS WELL LOGGINGDetector bull Scintillator NaI(Tl) Oslash 18times30 mm
Measurement rangebull Flux density measurement range 10 divide 105 s-1cm-2
bull Dose rate H(10) for Cs-137 5 divide 2104 μRhbull Sensitivity for Cs-137 200 (pulsess-1)( μSvh-1)
Overall dimensions weightbull Oslash 38times535 mm 36 kgbull Cable length 10 divide 1000 m
NEUTRON BDMN-96Detector bull Scintillator with ZnS(Ag)
Measurement rangebull Dose rate H(10) 01 μSvh divide 01 Svhbull Dose H(10) 01 μSv divide 10 Sv
Energy range bull 0025 eV divide 10 MeV
Overall dimensions weightbull Detector Oslash 54times200 mm 08 kgbull Moderator Oslash 245 mm 73 kg
NEUTRON-SEARCH BDKN-96Detector bull He-3 counter in polyethilene moderator
Measurement rangebull Dose rate H(10) for Pu-Be 01 μSvh divide 01 Svhbull Dose H(10) for Pu-Be 01 μSv divide 10 Sv
Energy range bull 0025 eV divide 14 MeV
Overall dimensions weightbull 295times142times100 mm 225 kg
BDKG-96M
BDMN-96
BDKN-96
SPC ldquoDozardquoRadiation monitoring equipment
60 61
bull No gas supply neededbull Clothing control detachable right hand detector bull Alpha detector optional connection bull Numeric and color (red green) indication of
control resultsbull LED sensor of hand-foot positioning for start of
measurementbull Automatic compensation of gamma background
and contamination of detectorbull Audible alarm signals of the excess of preset
thresholdsbull Measurement value indication min-1cm-2 or
Bqсm2
Reference standards Nuclear IEC 61098
RZB-05D HAND-FOOT-CLOTHING MONITOR
Physical characteristicsDetectors bull Gamma beta - GM countersbull Alpha - scintillatior ZnS(Ag)
Detecting nuclidesbull Alpha Pu-239 U-234 U-238bull Beta Sr-90+Y-90 F-18 Cs-137 Co-60 Tс-99 O-15
N-13 Sr-89 C-11 I-131 Na-22 Ru-106+Rh-106 Tl-204
bull Gamma Tc-99m I-123
Efficiencybull Alpha
Pu-239 40 U-234 25U-238 15
bull Beta Sr-90 +Y-90 40
Measurement range bull Alpha 1 divide 103 min-1cm-2 bull Beta 10 divide 103 min-1cm-2
bull Gamma 5103 divide 5106 min-1cm-2
Energy range bull Alpha 30 divide 80 MeV bull Beta 008 divide 35 MeV bull Gamma 005 divide 30 MeV
Operation temperature range bull Minus 10 divide +50 ordmС
Electrical characteristicsbull Power supply 220 V 50 Hz
Mechanical characteristicsOverall dimensions weight bull 740times750times1180 mm 45 kg
Versionsbull Withwithout alpha detectorbull Indication (min-1cm-2 ) or (Bqсm2)bull Detectors overall dimensions smbull Hand 178 х 235bull Foot 185 х 436
Whole body contamination monitor RZBA-04-04Mbull No gas supply neededbull Compensation for background gamma radiation
and contamination of detector unitsbull Individual threshold setting for each measure-
ment channelbull Visible and audible alarms ldquoCONTAMINATIONrdquo and
ldquoCLEANrdquo bull Indication of contaminated body parts on the
panel with image of the bodybull Optional remote alpha-detector
Physical characteristicsDetectors bull Beta - GM counters scintillatorsbull Alpha - scintillatior ZnS(Ag)
Measurement range bull Beta 5 divide 15000 min-1cm-2
bull Alpha 01 divide 10000 min-1cm-2
Energy range bull Beta 015 divide 25 MeV bull Alpha 40 divide 56 MeV
Operation temperature range bull +5 divide +50 ordmС
Electrical characteristicsPower supply bull 220 V 50 Hz
Interfaces bull RS-232bull RS-485
Mechanical characteristicsOverall dimensions weight bull 2650times940times930 mm 310 kg
Versionsbull Withwithout alpha detectorbull Indication (min-1cm-2 ) or (Bqсm2)
Reference standards Nuclear IEC 61098
RZBA-04-04MWHOLE BODY CONTAMINATION MONITOR
SPC ldquoDozardquoRadiation monitoring equipment
62 63
RZA-05DALPHA HAND-MONITOR
bull No gas supply needed bull Numeric and color (red green) indication of
control resultsbull LED sensor of hand- positioning for start of
measurementbull Audible alarm signals of the excess of preset
thresholdsbull Measurement value indication min-1cm-2 or
Bqсm2
Physical characteristicsDetectors alpha - scintillatior ZnS(Ag)
Efficiencybull Pu-239 20 bull U-234 14bull U-238 8
Measurement range bull 05 divide 105 min-1cm-2
Energy range bull 41 divide 90 MeV
Operation temperature range bull minus 10 divide +50 ordmС
Electrical characteristicsPower supply bull 220 V 50 Hz
Mechanical characteristicsOverall dimensions weight no more bull 740times1400times1450 mm 70 kg
Reference standards Nuclear IEC 61098
bull Simultaneous measurement of alphabeta activi-ties in the sample
bull Active shielding anti-coincidence background subtraction using GM counters
bull Lead shielding 30 mm
UMF-2000 LOW LEVEL ALPHA- BETA- COUNTER
Physical characteristicsDetectors bull Silicon specrometric detector 500 or 1000 mm2
Measurement range bull Alpha 001 divide 1000 Bq bull Beta 01 divide 3000 Bq
Energy range bull Alpha 35 divide 80 MeV bull Beta 005 divide 35 MeV
Electrical characteristicsPower supply bull 220 V 50 Hz
Interfaces bull RS-232bull USB
Mechanical characteristicsOverall dimensions weight bull 337times286times190 mm 22 kg
Versionsbull Detector area 500 mm2
bull Detector area 1000 mm2
UMF-2000 Detector area 1000 mm2
UMF-2000 Detector area 500 mm2
SpectraDec software for alpha-spectrometric measurements
SPC ldquoDozardquoRadiation monitoring equipment
64 65
DRK DOSE AREA PRODUCT METER
DRK-1bull Diagnostic reference level (DRL) of patients
determinationbull Suitable for all basic types of x-ray machines
Physical characteristicsDetector bull Plane-parallel ionization chamber
Measurement range bull 1 divide 104 cGycm2
Electrical characteristicsPower supply bull 220 V 50 Hz
DRK-1M-CTbull Measuring of dose length product
Physical characteristicsDetector bull Pencil Ionization Chamber
Measurement rangebull 05 divide 109 microGym
DRK-1Mbull Measuring of air kerma on sectional area of the
X-ray beam productbull Measuring of air kerma rate on area productbull Measuring of air kerma ratebull Measuring of air kerma
Physical characteristicsDetector bull Plane-parallel ionization chamber
Measurement rangebull 01 divide 109 microGym2
bull 06 divide 6104 microGym2cbull 30 divide 9105 microGycbull 30 divide 9991011 microGyReference standard IEC 60580 2003
bull Measurement of strontium-90 in the foodstuffs agricultural products etc
bull Measurement of gross beta activity in samplebull Self tests using built-in LED
ldquoPROGRESS-BETArdquo SCINTILLATION BETA SPECTROMETER
Physical characteristicsDetector bull Plastic scintillator Oslash70x10 mm
Sample bull Plate Oslash70 mmbull Weight up to 15 g
Energy range bull 02 divide 30 MeV
Minimum detectable activity of Sr-90 in a 10 g sample on a standard planchet Bqsamplebull In case of absence of K-40 in the sample 01 Bqbull In case the activity of K-40 till 5 Bqg 05 Bq
Electrical characteristics Interface bull USB
Mechanical characteristicsWeight bull No more 50 kg
Complete setBasic complete setbull Detector unit with plastic scintillator integrated
power supply amplifier ADC bull Lead shielding bull ldquoProgressrdquo software bull Сheck source for energetic calibration (Sr-90-Y-90) bull Planchet Oslash 70 mm (5 items) bull Sample dencification device bull Procedure manual for measurement of radio-
nuclidesrsquo activity using the scintillation beta spec-trometer ldquoProgressrdquo
Optional equipment and servicebull Personal computer and printer bull Calibrations for radionuclides not included in the
main library of radionuclides
Progress-Beta
Reference standards IEC 61562
SPC ldquoDozardquoRadiation monitoring equipment
66 67
bull Measurement of gamma activity in foodstuffs soil samples and others environmental objects
bull Identification of radionuclides in the sample bull Automatic correction for sample density bull Self-tests using built-in LED
ldquoPROGRESS-GAMMArdquoSCINTILLATION GAMMA SPECTROMETER
Physical characteristicsDetector bull NaI (Tl) Oslash63times63 mm
Validated measurement geometries bull Marinelli beakers (1 liter) Petri dishes (Oslash90 mm)
etc
Energy range bull 02 divide 30 MeV
Minimum detectable activity Bqsamplebull Cs-137 3 Bqbull Th-232 7 Bqbull Ra-226 8 Bq bull К-40 40 Bq
Electrical characteristics Interface bull USB
Mechanical characteristicsWeight bull No more 120 kg
Complete setBasic complete setbull Scintillation detector unit with NaI (Tl) detector
with integrated power supply amplifier and ADC bull Lead shielding 50 mm bull ldquoProgressrdquo software bull Сheck source for energy calibration (Cs-137 +
K-40)bull Marinelli beakers - 1 liter (5 items) bull Petri dishes Oslash 90 mm (5 items) bull Procedure manual for measurement of activity
of radionuclides using the scintillation gamma spectrometer ldquoProgressrdquo
Optional equipment and servicebull Kit for radon measurements including calibration
of ldquoIC-63rdquo geometry for counting the charcoal samples
bull Personal computer and printer bull Calibrations for user defined geometries bull Calibrations for radionuclides not included in the
main library of radionuclides
Progress-Gamma
Reference standards IEC 61563
ldquoPROGRESS-G(P)rdquoPORTABLE SCINTILLATION GAMMA SPECTROMETERbull Field measurements of gamma activity in environ-
mental objects without sampling (4π geometry)bull Laboratory measurement of gamma activity in
foodstuffs soil samples and others environmental objects
bull Identification of radionuclides in the sample bull Automatic correction for sample densitybull Tests using built-in LED
Physical charachteristicsDetector bull NaI (Tl) Oslash45times50 mmbull Lead shielding 20 mm
Validated measurement geometries bull Marinelli beakers (05 liter) Petri dishes (Oslash90 mm)
etc
Energy range bull 02 divide 30 MeV
Minimum detectable activity in 05-litre Marinelli beaker bull Cs-13710 Bqkgbull К-40100 Bqkgbull Ra-22618 Bqkg bull Th-23216 Bqkg
Minimum detectable activity in 30 min (4π geometry) bull Cs-137 2 Bqkgbull К-40 30 Bqkgbull Ra-226 4 Bqkg bull Th-232 3 Bqkg
Electrical characteristicsPower supply bull Rechargeable batterybull 220 V 50 Hz
Interface bull USB RS-232
Weight bull No more than 60 kg
Complete setBasic complete setbull Scinttillation detector unit with NaI(Tl) bull ldquoProgressrdquo softwarebull Сontrol unit ldquoSputnikrdquo for aquisition and analisys
of spectra with built-in memory for spectral databull Casebull Lead shielding (2 cm) for laboratory usebull 05-litre Marinelli beakers ndash 5 itemsbull Na-22 check sourcebull Power adapter BPS-01bull Operation manualbull Procedure manual for measurement of activity
of radionuclides using the scintillation gamma spectrometer ldquoProgressrdquo
Optional equipment and servicebull Kit for radon measurements with charcoalbull Built-in dose rate meterbull Additional memory (RAM) for storage of 64
spectrabull Additional power adapterbull Notebook and printer
Progress-Gamma
Reference standards IEC 61563
SPC ldquoDozardquoRadiation monitoring equipment
68 69
Physical characteristicsDetectorbull Scintillation detector ZnS (Oslash 60 mm)
Samplebull Thin sample - diameter up to 70 mm bull Preparation technique - electro-depositionbull Thick sample - diameter 70 mm weight
200300 mg bull Preparation technique - application of powders
(prepared by radiochemical concentration by water evaporation or by pounding of mineral samples) onto a planchet with the help of spirit
Energy rangebull 15 divide 8 MeV
Minimum detectable activitybull Thin samples no more than 910-3 Bqsamplebull Thick samples no more than 180 Bqkg
Mechanical characteristicsOverall dimensions weightbull 195times120times210 mm 34 kg
Complete setBasic complete setbull Alpha radiometer ldquoProgress-ARrdquobull Check source (uranium isotopes)
Set of accessoriesbull Procedure manual for measurements of radi-
oactivity using scintillation alpha radiometer ldquoProgress-ARrdquo
bull ldquoProgressrdquo software
ldquoProgress-ARrdquo
bull Measurement of gross activity of alpha emitting radionuclides in thin samples
bull Measurement of gross activity of alpha emitting radionuclides in thick samples
bull Measurement of activity deposited on aerosol filters
ldquoPROGRESS-ARrdquoALPHA RADIOMETER
Several fixed positions of the detector enable to perform measurements in various geometries and to estimate the content ofbull Cs-137 in the whole bodybull I-131 in thyroidbull Co-60 Cs-137 Mn-54 Cr-51 in lungsbull Database for storage of measurement data and
resultsbull Uncertainty calculations based on measurement
databull Self tests using built-in LED
ldquoPROGRESSrdquo WHOLE BODY COUNTER
Physical characteristicsDetectorbull scintillation detector NaI (Tl) Oslash63times63 mm
Energy rangebull 02 divide 28 MeV
Minimum detectable activitybull By Cs-137 in the whole body - 1200 Bqbull By I-131 in thyroid - 100 Bqbull By Co-60 Cs-137 Mn-54 Cr-51 in lungs - 200 Bq
Mechanical characteristicsWeight bull No more than 120 kg
Complete setBasic complete setbull Collimator with rotator and holderbull Detector with incorporated ADCbull Patient chair and table for collimatorbull Check source Na-22bull Procedure manual for lifetime measurement of
gamma-emitting radionuclidesrsquo activity in human body using the gamma-spectrometer of human radiation ldquoProgressrdquo
bull laquoProgressraquo software
Optional equipment and servicebull Program of internal radiation committed internal
radiation effective dose calculation by the stand-ard model
bull Background phantombull Personal computer and printer
Collimator with rotator and holder
SPC ldquoDozardquoRadiation monitoring equipment
70 71
bull Categorization of wastes for the purpose of fur-ther processing including wastes with unknown radionuclide composition
bull Measurements during the incoming waste inspec-tion (accepting for storage disposal)
bull Certification of unconditioned and conditioned wastes in closed containers without opening them (at nuclear plants or at facilities providing collection storage transportation conditioning processing temporal storage and final disposal of radioactive waste)
bull Activity measurement of extended objects in situ without opening the equipment
bull Activity measurement of extended objects after opening (for example assessment of tubes used for oil transportation)
MKG-01D ldquoSADOVNIKrdquoSPECTROMETRY SYSTEM
Physical charachteristicsDetectorbull Detector unit GEM (GMX) with HPGe detector and
multi-positioning cryostat CFG-PMOD4-7 with 7 litre Dewar
bull Dose rate probe BDMG-200
Energy range bull With GEM detector 004 divide 30 MeVbull With GMX detector 0005 divide 15 MeVbull Dose rate probe BDMG-200 ndash 005 divide 30 MeV
Measurement rangebull 110-7 divide 10 Svhbull Relative efficiency of detection (in photopeak) at
13325 MeV (Co-60) 10 divide 150
Electrical characteristicsPower supplybull 220 V 50 Hz
Interfacebull USB
Complete setBasic complete setbull Spectrometric detector unit GEM (GMX) with
HPGe detector and multi-positioning cryostat with 7 litre Dewar
bull Portable digital multichannel analyzer DigiDARTbull Dose rate probe BDMG-200bull Autonomous power supply unit with built-in
batterybull Industrial computer keyboardbull Laser range-finderbull Thermographic printerbull Web-camerabull Device equipped with stepper motor for position-
ing of the spectrometric detectorbull Calibration device with reference sources
(Am-241 Co-60 Ba-133 Eu-152) for energy calibration
bull Removable collimators with end capbull Measurement proceduresbull ldquoClasterrdquo software
bull Measurement of gross alpha activity of alpha-emitting radionuclides
bull Measurement of alpha-emitting radionuclides activity in thin-layer samples meeting alpha-spectrometry requirements
Physical characteristicsDetectorbull Silicon ion-implanted 450 mm2
bull Easy to decontaminate thin windowbull dead layer less than 015 μmbull Background count rate in the range 3 divide 9 MeVbull No more than 09 h-1cm-2 for 450 mm2 detector
Energy rangebull 2 divide 9 MeVbull Lower limit of measurement range (minimum
detectable activity) 01 Bqbull Background count rate no more than 100 counts
in 24 hours
Electrical characteristics Power supplybull 220 V 50 Hz
Interfacebull USB
Complete setBasic complete setbull Detector unit with vacuum measuring chamber
and vacuum control systembull Low noise vacuum pump (type 2FY-05B or
equivalent)bull Check sourcebull ldquoProgressrdquo softwarebull Vacuum tube
MKS-01A ldquoMULTIRAD-ASrdquoALPHA SPECTROMETER
SPC ldquoDozardquoRadiation monitoring equipment
72 73
UCRV-2AIRFLOW MONITOR
bull Monitor of the air flow through filter of centralized multichannel sampling system
bull Radiation monitoring system (RMS) integration for internal exposures determination
bull Volume and flow rate measurements of the air that have passed through a analytical filter
bull Bar-code for filter identificationbull Operation as either standalone unit or as a part of
the RMS
Physical characteristicsMeasurement range of air volume bull 001 divide 9999 m3
Operation temperature range bull minus 20 divide +50 ordmС
Electrical characteristicsPower supply bull 220 V 50 Hz
Interface bull RS-485
PVP-06PORTABLE AIR SAMPLER
Air Sampler PVP-06 is indispensable for monitoring the radiation situation where the concentration of radioactive aerosols in the air does not require a sta-tionary sampling equipment Sampling head PVP-06 provides easy change of filters and cartridges
Purposebull To monitor the concentration of radioactive aero-
sols in the air sites
Controlled aerosolsbull Alpha- and beta-active aerosolsbull Daughter products of decay of radon and thoronbull Iodine isotopes
Physical characteristicsTypes of filtersbull Aerosol AFA-RSP-20bull Iodine AFA SI-20
Flow rate bull 33∙10-4 ndash 233∙10-4 m3s (20 divide 140 l min)
Electrical characteristicsPower supply bull 220 V50 Hzbull The vehicle power supply 108 divide 145 Vbull Internal battery
Minimal working time on internal battery to recharge bull 8 hours
Power consumption (at a flow rate of 100 lmin) bull 40 VA
Environment characteristicsOperating temperature bull minus 10 divide +40 deg C
Maximum humidity bull 90
Pressure bull 860 to 1060 hPA
Noise generated by the pump bull lt 55 dBA at 1 m
Mechanical characteristicsDimensions weight bull 241 times 108 times 160 mm 28 kg
Case material bull Plastic
Complete setbull Air sampler PVP-06bull AC power adapterbull Filters AFA-RSP-20 - 100 pcsbull Packaging for filters - 40 pcsbull Casebull Operation manualbull Calibration certificate
Optional equimpient bull Kit for sampling sorption columns of activated
carbon Ř head of sorption columns with protective
covers Ř activated charcoal SKT-3 - 1 pkg (02 L) Ř charocoal samples SC-13 - 8 pcs
bull Car charger bull Tipod bull Shoulder strapbull Calibration stand bull Filters AFA SI-20 - 100 pcs
Consumablesbull Aerosol filters AFA RSP-20bull Iodine filters AFA SI-20
SPC ldquoDozardquoRadiation monitoring equipment
74 75
Calibration of gamma dose and dose rate meters
Calibration ofbull Ambient equivalent dose H(10) meters (Sv Svh)bull Personal equivalent dose Hp(10) meters (Sv Svh)bull Exposure dose X meters (R Rh)bull Two sources in irradiator bull Select source and collimator opening using
tumbler
UPG-P DESKTOP GAMMA BEAM IRRADIATOR
Physical characteristicsRange of reproduced dose rate bull 05 μSvh divide 10 mSvh (50 μRh divide 100 mRh)
Sources activities bull 6times106 6times108 Bq (02 20 mCi) Cs-137
Overall dimensions bull 1250times400times300 mm
Irradiator weight bull Not more than 37 kg
Calibration bench weight bull Not more than 15 kg
Reference standards IEC 60846 IEC 61526
Physical characteristicsDetectorbull Silicon
Measurement range EEC measurement bull Measurement range of radon EEC
10 divide 10bull106 Bqbullm-3
bull Measurement range of thoron EEC 05 divide 10bull104 Bqbullm-3
bull Air flow through the filter 100plusmn05 lmin
Concentration measurementbull Measurement range of radon-222 concentration
in air 10 divide 20bull106 cpsbull Measurement range of 216Po(ThA)
1bull10-3 divide 1bull102 cpsbull Air sampler flow rate
10plusmn02 lminbull Measurement range of radon-222 concentration
in water samples 6 divide 800 Bqbullkg-1
bull Measurement range of radon-222 flux from soil surface 20 divide 103 mBqsbullm2
bull Measurement range of radon-222 concentration with preliminary sampling of air using air sam-plers 20 divide 107 Bqbullm-3
bull Measurement range of radon-222 concentration in samples of soil air 103 divide 106 Bqbullm-3
Operation temperature range bull 1 divide 35 ordmC
Electrical characteristicsPower supply bull 80 VA
Mechanical characteristicsOverall dimensions weight bull 220times200times165 mm 36 kg
ldquoALPHARAD PLUSrdquoRADON THORON amp THEIR PROGENY MONITORbull Measurement of radon and thoron concentration
and effective equivalent concentration (EEC)bull In the airbull In the indoor air of residential public and industri-
al buildings and structuresbull Measurement of radon in drinking water sourcesbull Measurements of radon flux from the soil surface
at land plots allocated for construction of houses public buildings and industrial facilities
bull Measurements of radon concentration in soil air
Reference standards IEC 61577
SPC ldquoDozardquoRadiation monitoring equipment
76 77
UKPN-2M-D NEUTRON BEAM IRRADIATOR
Reference standards IEC 61005 61322
Calibration of neutron dose and dose rate meters
Calibration ofbull Ambient equivalent dose H(10) meters (Sv Svh)bull Personal equivalent dose Hp(10) meters (Sv Svh)bull Flux density of neutrons (cm-2∙s-1)bull Transfer container for temporary storage of
sources bull Red light signal of source working position
Physical carachteristicsRange of reproduced dose ratebull 20 divide 800 μSvh
Range of reproduced flux densitiesbull 10 divide 400 cm-2∙s-1
Type of a source in use bull Pu-Be
Activity of a source in usebull 24х1011 Bq (with density of 107 s-1)
Overall dimensions weight no morebull 3000x750x2000 mm 300 kg
Required room dimensionsbull not less than 7x3x3 m
Electrical characteristicsPower supply bull 220 V 50 Hz
Calibration of gamma dose and dose rate meters
Calibration ofbull Ambient equivalent dose H(10) meters (Sv Svh)bull Personal equivalent dose Hp(10) meters (Sv Svh)bull Exposure dose X meters (R Rh)bull Four sources in irradiator bull Select source and move to working position
return to storage position using special rodbull Transfer container for temporary storage of
sources bull Red light signal of source working position
UPGD-2M-DGAMMA BEAM IRRADIATOR
Physical characteristicsRange of reproduced dose rate bull 05 μSvh divide 50 mSvh (50 μRh divide 5 Rh)
Maximum activity of source bull 2times1011 Bq (50 Ci) Cs-137
Overall dimensionsbull Irradiator 800times500times500 mmbull Guide rails length 30 mbull Height 16 mbull Weight not more than 700 kgbull Required room dimensions not less than 7x3x3 m
Electrical characteristicsPower supply bull 220 V 50 Hz
UPGD-2M-D
Reference standards IEC 60846 IEC 61526 IEC 61066
SPC ldquoDozardquo
78 79
Contents
MEASURING UNITS
DBG-S11D wide range gamma area monitor 40
UDKS-100 gamma and X-ray area monitor 41
UDMN-100 neutron area monitor 41
ALARM UNITS
BAS-2 ldquoMICROrdquo external visual alarm 42
BZS-2 ldquoMicrordquo external audible alarm 42
Illuminated warning signs 43
ldquoImpulsrdquo external display unit 43
UIM-3D area monitor count rate meter 44
DKG-05D personal gamma dosimeter 46
DVS-02D gamma-neutron personal electronic dosimeter 47
DVGI-8D new pen-type personal ionization chamber dosimeters 48
DKG-02U ldquoARBITERrdquo wide range gamma-dosimeter 49
DKG-07D ldquoDROZDrdquo gamma-dosimeter 50
MKS-15D ldquoSNEGIRrdquo multi ndash purpose radiation survey meter 51
SRPS-05D gamma monitor 52
DOZA-TLD multipurpose TLD system 53
DKS-96 universal radiation survey meter 54
EXTERNAL PROBES ALPHA
Alpha BDZA-96 55
Alpha BDZA-96B 55
Alpha BDZA-96M 55
Alpha BDZA-96S 55
Alpha BDZA-96T 55
EXTERNAL PROBES BETA
Beta BDZB-96 56
Beta BDZB-99 56
Beta BDZB-96B 56
Beta BDZB-96S 56
EXTERNAL PROBES GAMMA
Gamma BDKS-96B 57
Gamma and beta BDKS-96S 57
Gamma BDMG-96 57
EXTERNAL PROBES GAMMA
Gamma-search BDVG-96 58
Gamma-search BDPG-96 58
ContentsRadiation monitoring systemldquoPELIKANrdquo Radiation monitoring system (RMS) 6
BDMG-101 high range gamma area monitor 10
DBG-S11D wide range gamma area monitor 11
BDRG-52 high range gamma area monitor for accident and post-accident conditions 12
UDGP-01 Liquid technological environments monitor 13
UDMN-100 neutron area monitor 14
UDKG-100 Wel Liquid gamma monitor 14
BOP-1M data processing and transmission unit 15
UDA-1AB particulate monitor 16
UDG-1B noble gas monitor 17
UDG-03D noble gas monitor 18
UDI-1B iodine monitor 19
UDGB-01 noble gasesH-3C-14 monitor 20
UDGP-01 steam generator leakage monitor 21
UPPVM air flow parameters monitor 22
ldquoIMPULSrdquo external display unit 23
BI-2 remote display amp alarm unit 24
BASBAS-1s external alarm 25
SKGAV stack monitor 26
RMS software 28
RMS workstation ndash operator console 29
Configurator software 29
RM RACK radiation monitoring rack 30
SRKS-01D criticality accident alarm system 32
ldquoATLANT-Mrdquo environmental radiation monitoring system 34
ldquoBREEZErdquo high-volume air sampler 35
ldquoGAMMA-SENSORrdquo gamma-survey system 36
Radiation monitoring equipmentAREA MONITOR ldquoFREGATrdquo 38
BPI-1D local display unit 39
80
Gamma-search BDPG-96M 58
Gamma BDKG-96 stainless steel casing for geologic applications well logging 59
EXTERNAL PROBES NEUTRON
Neutron BDMN-96 59
Neutron-search BDKN-96 59
RZB-05D Hand-foot-clothing monitor 60
RZBA-04-04M whole body contamination monitor 61
RZA-05D alpha hand-monitor 62
UMF-2000 low level alpha- beta- counter 63
DRK dose area product meter 64
ldquoPROGRESS-BETArdquo scintillation beta spectrometer 65
ldquoPROGRESS-GAMMArdquo scintillation gamma spectrometer 66
ldquoPROGRESS-G(P)rdquo portable scintillation gamma spectrometer 67
ldquoPROGRESS-ARrdquo alpha radiometer 68
ldquoPROGRESSrdquo whole body counter 69
MKG-01D ldquoSADOVNIKrdquo spectrometry system 70
MKS-01A ldquoMULTIRAD-ASrdquo alpha spectrometer 71
UCRV-2 airflow monitor 72
PVP-06 portable air sampler 73
ldquoALPHARAD PLUSrdquo radon thoron amp their progeny monitor 74
UPG-P desktop gamma beam irradiator 75
UPGD-2M-D gamma beam irradiator 76
UKPN-2M-D neutron beam irradiator 77
Radiation monitoring system SPC ldquoDozardquo
34 35
ldquoBREEZErdquoHIGH-VOLUME AIR SAMPLER
Physical characteristicsbull Measurement range of air flow rate
250 divide 1200 m3hbull Continuous operation time not less than 24 h
Filter materialsbull High-purity glass fiberbull Pure quartz or cellulosebull Filter fabric FPP-15-15
Electrical characteristicsPower supply bull 220380 V 50 Hz
Interfaces bull RS-485bull Ethernetbull GSMGPRS (option)
Environmental characteristicsTemperature range bull minus 40 divide + 40 ordmC
Relative humidity limit at 35 ordmC bull 95
Atmospheric pressure range bull 840 divide 1067 kPa
Versionsbull Standalone unit bull Part of Environmental Radiation Monitoring
System (ERMS)
Type of detection unitsbull Beta block BDZB-100Lbull DBG-S11D wide range gamma area monitorbull Scintillation spectrometric block
The motor of Air Sampler is controlled by an electronic flow sensor that detects changes in the operators pre-set flow rate caused by changes in temperature barometric pressure and pressure drop due to dust loading on filter media It compensates for these changes by adjusting the motor speed to maintain the pre-set flow ratebull Measurement of parameters of ionizing radiation bull Standalone mode of operation or as the part
of Environmental Radiation Monitoring System (ERMS)
Purposebull Environmental Radiation Monitoring System
(ERMS) in the control and buffer areas of the radia-tion and nuclear facilities
Referencesbull Since the year 2000 the system is successfully
operating the ERMSs at 8 Russian nuclear power plants (about 180 monitoring stations)
bull Since the year 2005 the ERMS is operating in the Moscow (about 40 monitoring stations)
bull Since the year 2005 the regional ERMS is under operation in several Russian Federation regions
Basic complete setMonitoring stations bull Data processing and transmission unit BOP-1TA bull Gamma area monitor DBG-S11D
Central data processing station (CDPS)bull Data processing and transmission unit BOP-1TAbull Server
By requestbull Emergency Response and Crisis Management
Centers for enterprisesbull Regional Emergency Response and Crisis Manage-
ment Centersbull rdquoBreezerdquo High-Volume Air Samplerbull Mobile lab with gamma-survey system rdquoGammandash
sensorrdquo
ldquoATLANT-MrdquoENVIRONMENTAL RADIATION MONITORING SYSTEM
Monitoring system for the continuous radiation monitoring of territories and facilities with the data transmission GSMGPRS network
Data transmission bull GSMGPRS
Power supply bull 220 V 50 Hz
Continuous autonomous operation (at 20 ordmC)bull From built-in battery not less than 5 hoursbull From external battery not less than 24 hours
Operation temperature bull Minus 40 divide +50 ordmC
Operation humidity bull Up to 98
Protection bull IP65
Reference standards Nuclear IEC 61017-11991 IEC 61017-21994
36
Radiation Monitoring Equipment
bull Localization of radioactive contaminationsbull Database with dose rate contaminations
spectra measurement date amp time coordi-nates
bull Work as part of mobile laboratory or as part of Environmental Radiation Monitoring System with real-time data transfer
Physical characteristicsDetector bull Scintillation NaI (Tl) GM counters
Measurement rangebull 01 ndash 107 μSvh
Energy range bull 005 ndash 3 MeV
Operation temperature range bull minus 10 divide +50 ordmС
Electrical characteristics bull Power supply 220 V 50 Hz
ldquoGAMMAndashSENSORrdquoGAMMA-SURVEY SYSTEM
SPC ldquoDozardquoRadiation monitoring equipment
38 39
AREA MONITOR ldquoFREGATrdquoArea Monitor ldquoFregatrdquo is designed for building rela-tively simple and inexpensive radiation monitoring systems at such facilities as radionuclide sources storage areas isotope products warehouses nuclear medicine departments PET centers calibration laboratories where sources of ionizing radiation are used etc
Small scale automated radiation monitoring systems built with ldquoFregatrdquo components featuring audible and visual alarms are matched suitable to meet the regulatory radiation safety requirements
Area monitor ldquoFregatrdquo requires virtually no adjust-ment it is simple and convenient for installation and operation
BPI-1D LOCAL DISPLAY UNIT
Display of monitored parameters values received from external measuring devices
Purposebull Processing and display of values of monitored
parameters on information panel bull Comparison of values of monitored parameters
with thresholdsbull Transfer of monitored parametersrsquo values to
networkbull Generation of alarm in case of exceeding of preset
thresholds including external alarm devices
FeaturesTesting the unit and connected devicesbull Visually on the panelbull Using adjustment software when connected to
PC via USB
Automatic self-testing
The panel displays the following informationbull Diagnostic information about the status of con-
nected devicesbull Current date and timebull Values of measured parametersbull Position of measured values with respect to the
thresholds in the form of scales with green yellow and red zones
bull Time history (trend) for each measured value
Physical characteristicsTemperature range bull minus 10 divide + 50 ordmC
Maximum number of connected devicesbull measuring devices 15bull external audible and visual alarm 15
Display diagonal bull 152 cm (6)
Electrical characteristicsbull Interfaces RS-485bull Power supply 220 V 50 Hz 12 divide 24 V
Mechanical characteristicsbull Protection index IP54bull Paint decontaminable
Overall dimensions weightbull 296x248x118 mm 5 kg
DBG-S11D wide range gamma area monitor
UDMN-100 neutron area monitor
Ethernet RS-485
UDKS-100 gamma and X-ray area monitor
BPI-1D Local display unit
BAS-2 ldquoMicrordquo external visual alarm
BZS-2 ldquoMicrordquo external audible alarm
ldquoImpulsrdquo external display unit
Service workstation
Illuminated warning signs
SPC ldquoDozardquoRadiation monitoring equipment
4140
Continuous automatic monitoring of the gamma- X-ray ambient dose equivalent rate
Physical characteristicsbull Detector tissue-equivalent plastic scintillator
Oslash 45times20 mm
Measurement range bull Dose rate measurement range 01 μSvh divide 1 Svh bull Energy range 0015 divide 10 MeV
Mechanical characteristicsbull Protection index IP65bull Paint decontaminable
Overall dimensions weightbull Oslash72times265 mm 15 kg
UDKS-100 GAMMA AND X-RAY AREA MONITOR
UDMN-100 NEUTRON AREA MONITOR
Physical characteristicsbull detector ndash scintillator ZnS(Ag) Li-6
Measurement range bull 01 μSvh divide 01 Svh
Energy range bull 0025 eV divide 100 MeV
Temperature range bull minus 45 divide +50 ordmC
Electrical characteristicsbull Interfaces RS-485
Mechanical characteristicsbull Protection index IP 65bull Paint decontaminable
Overall dimensions weight bull 428times258times347 mm 115 kg
Continuous automatic monitoring of the neutron-radiations ambient dose equivalent ratebull Spherical polyethylene moderator Oslash 239 mm
MEASURING UNITS
DBG-S11D WIDE RANGE GAMMA AREA MONITOR
Continuous automatic monitoring of the gamma- ambient dose equivalent rate
Physical characteristicsbull Detector ndash GM counters
Measurement rangebull DBG-S11D 01 μSvh divide 10 mSvhbull DBG-S11D-01 01 μSvh divide 10 Svhbull DBG-S11D-02 01 μSvh divide 100 Svh
Energy rangebull 005 divide 30 MeV
Temperature range bull minus 40 divide +50 ordmC
Electrical characteristicsbull Interfaces RS-485 USB
Mechanical characteristicsbull Protection index IP 68bull Paint decontaminable
Overall dimensions weightbull DBG-S11D Oslash 68times141 mm 065 kg bull DBG-S11D-01 Oslash 68times179 mm 07 kgbull DBG-S11D-02 Oslash 68times179 mm 07 kg
Versionsbull DBG-S11Dbull DBG-S11D-01bull DBG-S11D-02
Reference standards Nuclear IEC 60846 IEC 60532 EMC IEC 61010 IEC 61000-6-2 Seismic IEC 60980
SPC ldquoDozardquoRadiation monitoring equipment
4342
ALARM UNITS
Generation visual signals of the excess of preset thresholds
Physical characteristicsLength of communication cablebull up to 1200 mbull Alarm Visual alarm green yellow red
Electrical characteristicsbull Power supply +12 V
Mechanical characteristicsbull Protection index IP 23
Overall dimensions weight 160times84times41 mm 02 kg
BAS-2 ldquoMICROrdquo EXTERNAL VISUAL ALARM
Generation audible signals of the excess of preset thresholds
Physical characteristicsLength of communication cablebull up to 1200 mbull Audible alarm 80 divide 100 dB at a distance of 1 m
Electrical characteristicsbull Power supply +12 V
Mechanical characteristicsbull Protection index IP 23
Overall dimensions weight 160times84times41 mm 02 kg
BZS-2 ldquoMICROrdquo EXTERNAL AUDIBLE ALARM
Physical characteristicsLength of communication cablebull up to 1200 m
Electrical characteristicsbull Power supply 220 V 50 Hz
Mechanical characteristicsbull Protection index IP 23
Overall dimensions weight bull 330times110times20 mm 05 kg
Physical characteristicsLength of communication cablebull up to 1200 m
Character height bull ldquoImpuls-910-Rrdquo 100 mmbull ldquoImpuls-915-D4Srdquo 150 mmbull ldquoImpuls-927-D4Srdquo 270 mm
Operating temperature rangebull ldquoImpuls-910-Rrdquo 0 divide +50 degCbull ldquoImpuls-915-D4Srdquo ldquo-727-D4Srdquo minus 40 divide +50 degC
Electrical characteristicsbull Power supply 220 V 50 Hz
Mechanical characteristicsProtection index bull ldquoImpuls-910-R IP 44bull ldquoImpuls-915-D4Srdquo ldquo-727-D4Srdquo IP 65
Overall dimensions weight bull ldquoImpuls-910-Rrdquo 400times160times60 mm 3 kgbull ldquoImpuls-915-D4Srdquo 815times250times80 mm 5 kgbull ldquoImpuls-927-D4Srdquo 1250times330times80 mm 5 kg
ILLUMINATED WARNING SIGNS
ldquoIMPULSrdquo EXTERNAL DISPLAY UNIT
SPC ldquoDozardquoRadiation monitoring equipment
4544
Individual threshold setting for each measurement channel
Continuous area and process monitoring
Collect amp display data from two measurement chan-nels (units with RS-485 or analog pulses)
Audible and visual alarms on exceeding preset thresholds or status of connected devices
Individual threshold setting for each measurement channel
Switching on the external alarm or executive devices when any threshold is exceeded
The wide panel displays the following information bull Values of measured parameters as min-1∙cm-2
s-1∙cm-2 μSvhbull Diagnostic information about the status of con-
nected devicesbull Current date and timebull Position of measured values with respect to the
thresholds in the form of scales with green yellow and red zones
bull Time history (trend) for each measured value
Physical characteristics Measurement range bull Count rate up to 107 CPM (170 kHz)
Operating temperature range bull minus 20 divide +50 ordmC
Electrical characteristics bull Power supply 220 V bull Interfaces USB
Mechanical characteristics bull Protection index IP 65 bull Overall dimensions weight 222times164times73 mm
40 kg
UIM-3D AREA MONITOR COUNT RATE METER
Measurement of alpha radiation flux density
Detector unit BDZA-100 (70 cm2) Measurement range 01 divide 104 min-1∙cm-2
Detector unit BDZA-100B (300 cm2) Measurement range 01 divide 2103 min-1∙cm-2
Measurement of beta radiation flux density
Detector unit BDZB-100 (28 cm2) Measurement range 10 divide 105 min-1∙cm-2
Detector unit BDZB-100L (30 cm2) Measurement range 10 divide 104 min-1∙cm-2
Detector unit BDZB-11D (84 cm2) Measurement range 5 divide 15∙104 min-1∙m-2
OPTIONAL PROBESMeasurement of gamma radiation flux density
Detector units BDEG-03 Measurement range 4 divide 2000 s-1∙cm-2
Detector unit UDKG-100 for operation in the rocks ore liquid media and sludge Measurement range 40 divide 8000 s-1∙cm-2
Measurement of the ambient dose equivalent rate
Detector unit DBG-S11D Measurement range 01 μSvh divide 100 Svh
Measurement of neutron radiation ambient dose equivalent rate
Detector unit BDMN-100 Measurement range 01 μSvh divide 01 Svh
SPC ldquoDozardquoRadiation monitoring equipment
46 47Reference standards Nuclear IEC 61526
Measurement of gamma-radiation personal dose equivalent Hp(10)bull Stand-alone dosimeter or composed of dosimetric
system onebull Audible and visual alarmbull Large memory dose accumulation historiesbull Exclusion of unauthorized intervention in dosim-
etry operation
DKG-05D PERSONAL GAMMA DOSIMETER
Physical characteristicsDetectors bull Silicon
Measurement range bull Dose rate 1 μSvh divide 10 Svhbull Dose 01 μSv divide 15 Sv
Energy range bull 005 divide 30 MeV
Electrical characteristicsbull Power supply rechargeable NiMH battery 1
alcaline battery (type AAA)
Operation timebull Till recharging not less 400 hoursbull With one set batteries not less 1000 hours
Mechanical characteristicsOverall dimensions weight bull 47times26times87 mm (with clip) 70 g
Environmental characteristicsbull IP65bull Temperature range minus 20 divide +45 ordmCbull Humidity up to 98 at 35 ordmCbull Shock vibration and drop resistant
Alarmbull Excess of alarm thresholdsbull Warnings of self-test failure and battery discharge bull Audible alarm 80 dB at 40 cmbull Visual alarm blinking LED
Relative equipmentbull One dosimeter charger ZU-1Mbull Chargestorage cassetes KZU-28KZU-56bull ldquoSmart chargingrdquo feature extends battery life timebull DKG-05D reader US-05bull DKG-05D system reader DVS-01D
Reader-PC interfacebull US-05 USB bull DVS-01D Ethernet
KZU-28
Physical characteristicsDetectors bull Silicon Li-6
Gamma measurement range bull Dose rate 1 μSvh divide 10 Svhbull Dose 01 μSv divide 15 Sv
Gamma energy range bull 005 divide 60 MeV
Neutron measurement range bull Dose rate 1 μSvh divide 2 Svhbull Dose 20 μSv divide 15 Sv
Neutron energy range bull 0025 eV divide 20 MeV
Electrical characteristicsPower supply bull Rechargeable NiMH batterybull Operatiion time till recharging not less 200 hours
Mechanical characteristicsOverall dimensions weight bull 47times26times87 mm (with clip) 70 g
Environmental characteristicsbull IP65bull Temperature range minus 20 divide +40 ordmCbull Humidity up to 75 at 30 ordmCbull Shock vibration and drop resistant
Alarmbull Excess of alarm thresholds bull Warnings of self-test failure and battery discharge bull Audible alarm 80 dB at 40 cmbull Visual alarm blinking LED
Relative equipmentbull One dosimeter charger ZU-1Mbull Chargestorage cassetes KZU-28 KZU-56bull ldquoSmart chargingrdquo feature extends battery life timebull DVS-02D reader UZS-01Sbull DVS-02D system reader DVS-01D
Reader-PC interfacebull UZS-01S USB bull DVS-01D Ethernet
UZS-01DReference standards Nuclear IEC 61526
DVS-02D GAMMA-NEUTRON PERSONAL ELECTRONIC DOSIMETER
Measurement of gamma- and neutron radiations personal dose equivalent Hp(10)bull Stand-alone dosimeter or composed of dosimetric
system onebull Audible and visual alarmbull Large memory dose accumulation historiesbull Exclusion of unauthorized intervention in dosim-
etry operationbull Both albedo thermal neutrons and intermediate
fast neutrons registrationbull Usable in the fields of Pu(Be) Po(Be) Cf and other
neutron sources as well as near nuclear reactors without neutron spectrum estimation
SPC ldquoDozardquoRadiation monitoring equipment
48 49
Dosimeters DVG-03D
DVGI-8D NEW PEN-TYPE PERSONAL IONIZATION CHAMBER DOSIMETERS
Measurement of personal dose equivalent Hp(10) of gamma and X-ray radiationbull Hp(10) of continuous and pulsed gamma and
X-ray radiation bull Electronic reader KSU-1bull Dosimeter DVG-03D with electronic ID bull Personal dose histories in the readerrsquos memorybull Readerrsquos connection with PC for database main-
tenance
Physical characteristicsDetector bull Ionization chamber
Measurement range bull 001 mSv divide 25 mSv
Energy range bull 0015 divide 25 MeV
Temperature range bull Reader KSU-1 +10 divide +50 ordmСbull Dosimeter DVG-03D minus 40 divide +50 ordmС
Electrical characteristicsPower supply bull Reader KSU-1 220 V 50 Hz built-in batteries bull Dosimeter DVG-03D four batteries CR 1025 bull Batteries life 3 yearsbull Readers interfaces RS-232USB 20
Mechanical characteristicsOverall dimensions weightbull Dosimeter DVG-03D Oslash 18times126 mm 005 kgbull Reader KSU-1 235times232times125 mm 28 kg
Reference standards Nuclear IEC 62387-1
DKG-02U ldquoARBITERrdquo WIDE RANGE GAMMA-DOSIMETER
Physical characteristicsDetectors bull GM counters
Measurement rangebull Dose-rate 01 μSvh divide 3 Svhbull Dose 1 μSv divide 100 Sv
Energy range bull 005 divide 3 MeV
Electrical characteristicsbull Power supply 2 alcaline batteries (type AA)bull Batteries life not less 200 hours
Mechanical characteristicsOverall dimensions weight bull 152times82times32 mm 03 kg
Environmental characteristicsbull Temperature range minus 20 divide +50 ordmCbull Humidity up to 90 at +25 ordmCbull Shock vibration and drop resistant
Reference standards Nuclear IEC 60846
Measurement of gamma radiation ambient equiva-lent dose H(10) and dose rate H(10)bull Audible signals (clicks) for radiation condition
estimationbull Analog scale for search modebull Audible and visual alarms of the excess of preset
dose and dose rate thresholds bull Shock-resistant water-proof easy decontamina-
tion casebull 100 measurement results memory with date and
time of measurementbull Indication of total dose accumulated during
exploitation time bull Indication of measurement result statistical
uncertainty
SPC ldquoDozardquoRadiation monitoring equipment
50 51
Physical characteristicsDetectors bull GM counter
Measurement rangebull Dose-rate 01 μSvh divide 3 mSvhbull Dose 1 μSv divide 02 Sv
Energy range bull 005 divide 3 MeV
Temperature range bull Minus 20 divide +50 ordmC
Electrical characteristicsbull Power supply 2 alcaline batteries 15 V (type AA)bull Batteries life not less 200 hours
Mechanical characteristicsOverall dimensions weight bull 122times74times29 mm 025 kg
Reference standards Nuclear IEC 60846
DKG-07D ldquoDROZDrdquoGAMMA-DOSIMETER
Measurement of gamma radiation ambient equiva-lent dose H(10) and dose rate H(10)bull Two independent measurement channels dose
and dose ratebull Audible signals (clicks) for radiation condition
estimationbull Continuous measurement with updating meas-
urement resultbull Measurement result can be obtained with any
desired statistical uncertainty (error)bull Automatic restart when radiation level sharply
changesbull Indication of statistical uncertainty (error) during
measurement process
Continuous measurement with updating measure-ment result
Automatic restart when radiation level sharply changes bull Gamma dose H(10) and dose-rate H(10) meas-
urementbull Beta and gamma contamination surveybull Indication of statistical uncertainty during the
measurementbull Continuous measurement with accuracy increas-
ing with time bull Automatic restart triggered by change of gamma
dose-ratebull Compensation of gamma count rate while meas-
uring beta radiationbull Indication of battery charge levelbull Audible signal of the excess of preset threshold
Physical characteristicsDetectors bull GM counter
Measurement range bull Dose-rate 01 microSvh divide 20 mSvhbull Dose 1 microSv divide 100 Svbull Beta flux density (for Sr-90+Y-90)
10 divide 105 cm-2 min-1
Energy range bull Gamma 005 divide 3 MeVbull Beta 01 divide 3 MeV
Temperature range bull Minus 20 divide +50 ordmC
MKS-15D ldquoSnegirrdquo backside
MKS-15D ldquoSNEGIRrdquoMULTI ndash PURPOSE RADIATION SURVEY METER
Reference standards Nuclear IEC 60846 IEC 60325
Electrical characteristicsbull Power supply 2 alcaline batteries (type AA)bull Battery life not less 400 hours
Mechanical characteristicsOverall dimensions weight bull 124times72times35 mm 035 kg
SPC ldquoDozardquoRadiation monitoring equipment
52 53
Physical characteristicsDetectorbull GM counter
Measurement range bull 01 μSvh divide 20 mSvh
Energy range bull 005 divide 30 MeV
Threshold setting range bull 03 μSvh divide 20 mSvh
Step change of the thresholdbull In the range 03 divide 10 μSvh with the step
001 μSvhbull In the range 10 divide 100 μSvh with the step
01 μSvhbull In the range 100 divide 2000 μSvh with the step
10 μSvh
Electrical characteristicsPower supply bull 220 V 50 Hz bull Relay output
Mechanical characteristicsProtection index bull IP 40
Overall dimensions weight bull 226times120times75 mm 07 kg
Alarmbull Sound alarm 80 divide 100 dBA at distance 1 mbull Visual alarm redbull Connection of the external alarm signaling unit
Reference standards Nuclear IEC 60846 IEC 60532
Continuous automatic monitoring of the ambient dose equivalent rate bull Measurement of gamma dose rate H(10)bull Audible and visual alarm signals for preset
thresholdsbull Switching on the external signaling or executive
devices
SRPS-05D GAMMA MONITOR
Measurement ofbull Gamma and X-ray personal dose equivalent
Hp(10)bull Neutron personal dose equivalent Hp(10)bull Lens dose equivalent Hp(3)bull Skin dose equivalent Hp(007)bull TLD reader day-to-day tests using built-in LEDbull No needs nitrogen for heating
Physical charachteristicsDetectors bull 7LiF Mg Ti (gamma beta)bull 6LiF Mg Ti (neutron)
Gamma and X-ray Hp(10) Measurement range bull 500 μSv divide 10 Sv
Energy range bull 0015 divide 30 MeV
Neutron Hp(10)Measurement range bull 01 mSv divide 100 mSv
Energy range bull 0025 eV divide 10 MeV
Beta and photons Hp(007) Hp(3) Measurement range bull 2 mSv divide 100 Sv
Energy range bull Beta 025 divide 35 MeVbull Photons lt15 keV
Mechanical characteristicsDosimeters overall dimensions weight bull Gamma Hp(10) DTL-2 holder - 62times26times16 mm
16 gbull DTU holder - 42times28times18 mm 8 gbull Lens Hp(3) face skin Hp(007) Oslash 32times16 mm 9 gbull Finger skin Hp(007) 90times20times2 mm 1 gbull Neutron gamma Hp(10) 48times40times20 mm 30 g
Reference standards Nuclear IEC 61066
DTL-2 DTU-2
MKD (A-type) DVNG-M
DOZA-TLD MULTIPURPOSE TLD SYSTEM
SPC ldquoDozardquoRadiation monitoring equipment
54 55
Continuous and pulsed gamma and X-ray dose H(10) and dose-rate measurementbull Alpha beta and gamma contamination surveybull Neutron dose H(10) and dose-rate measurementbull Gamma radiation flux density in boreholes and
liquid media measurement
Electrical characteristicsPower supply bull UIK-05 four C-size batteriesbull UIK-05-01 rechargeable batterybull UIK-06 rechargeable battery
Interfaces bull RS-232bull USB (via adapter)
bull Detector type automatic determination and corre-sponding measurement modes selection
bull Alarm threshold settings ndash for dose dose-rate alpha and beta contaminations
bull ldquoDetectrdquo and ldquoLocaterdquo modes for survey probes
Reference standards Nuclear IEC 60846 IEC 60325 IEC 61005 IEC 62363
Case
UIK-06 control unit165times78times48 mm 03 kg
DKS-96UNIVERSAL RADIATION SURVEY METER
UIK-05 control unit202times86times90 mm 10 kg
BDZA-96
BDZA-96B
BDZA-96M
BDZA-96S
BDZA-96T
EXTERNAL PROBES ALPHAALPHA BDZA-96Detector bull ZnS(Ag) 70 cm2
Measurement range (for Pu-239)bull 01 divide 104 min-1cm-2
Overall dimensions weightbull Oslash 130times240 mm 11 kg
ALPHA BDZA-96BDetector bull ZnS(Ag) 300 сm2
Measurement range (for Pu-239)bull 01 divide 2103 min-1cm-2
Overall dimensions weightbull Oslash 230times290 mm 40 kg
ALPHA BDZA-96MDetector bull ZnS(Ag) 10 сm2
Measurement range (for Pu-239)bull 01 divide 105 min-1cm-2
Overall dimensions weightbull Oslash 65times240 mm 09 kg
ALPHA BDZA-96SDetector bull ZnS(Ag) 30 сm2
Measurement range (for Pu-239)bull 01 divide 5104 min-1cm-2
Overall dimensions weightbull Oslash 90times240 mm 10 kg
ALPHA BDZA-96TDetector bull Silicon 5 сm2
Measurement range (for Pu-239)bull 01 divide 106 min-1cm-2
Overall dimensions weightbull Oslash 50times60 mm 015 kg
SPC ldquoDozardquoRadiation monitoring equipment
56 57
BETA BDZB-96Detector Scintillator 28 сm2
Measurement range (for Sr-90+Y-90)bull 10 divide 105 min-1cm-2
Energy rangebull 03 divide 30 MeV
Overall dimensions weightbull Oslash 90times230 mm 09 kg
BETA BDZB-99Detector bull GM counter 30 сm2
Measurement range (for Sr-90+Y-90)bull 20 divide 104 min-1см-2
Energy rangebull 012 divide 30 MeV
Overall dimensions weightbull Oslash 88times80 mm 04 kgbull Telescopic pole length 07 m
BETA BDZB-96BDetector bull GM counter 80 сm2
Measurement range (for Sr-90+Y-90)bull 3 divide 104 min-1сm-2
Energy rangebull 012 divide 30 MeV
Overall dimensions weightbull 150times200times110 mm 15 kg
BETA BDZB-96Sbull Detector GM counter 15 сm2
Measurement range (for Sr-90+Y-90)bull 10 divide 3104 min-1cm-2
Energy rangebull 012 divide 30 MeV
Overall dimensions weightbull Oslash 65times65 mm 03 kgbull Telescopic pole length 07 m
BDZB-96
BDZB-99
BDZB-96B
BDZB-96S
EXTERNAL PROBES BETA
GAMMA BDKS-96BDetector bull Tissue-equivalent scintillator Oslash 45times20 mm
Measurement rangebull Dose rate H(10) 01 μSvh divide 1 Svhbull Dose H(10) 01 μSv divide 10 Sv
Energy rangebull 0015 divide 10 MeV
Overall dimensions weightbull Oslash 60times250 mm 085 kg
GAMMA AND BETA BDKS-96SDetector bull Double GM counters
Measurement rangebull Gamma dose rate H(10) 01 μSvh divide 1 mSvhbull Gamma dose H(10) 01 μSv divide 10 Svbull Beta 10 divide 3104 min-1cm-2
Energy rangebull Gamma 005 divide 3 MeVbull Beta 012 divide 3 MeV
Overall dimensions weightbull Oslash 80times80 mm 035 kgbull Telescopic pole length 07 m
GAMMA BDMG-96Detector bull GM counters
Measurement rangebull Dose rate H(10) 01 μSvh divide 10 Svhbull Dose H(10) 01 μSv divide 10 Sv
Energy range bull 005 divide 3 MeV
Overall dimensions weightbull 40times250 mm 05 kgbull Telescopic pole length 07 m 4 m (by request)
EXTERNAL PROBES GAMMA
BDKS-96B
BDMG-96
BDKS-96S
SPC ldquoDozardquoRadiation monitoring equipment
58 59
GAMMA-SEARCH BDVG-96Detector bull Scintillator NaI(Tl) Oslash 63times63 mm
Measurement rangebull Flux density measurement range 4 divide 2000 s-1cm-2
bull Dose rate H(10) for Cs-137 01 divide 30 μSvhbull Sensitivity for Cs-137 3000 (pulsess-1)( μSvh-1)
Overall dimensions weightbull Oslash 88times400 mm 20 kgbull Modular pole length 16 m
GAMMA-SEARCH BDPG-96Detector bull Scintillator NaI(Tl) Oslash 25times40 mm
Measurement rangebull Flux density measurement range 10 divide 8000 s-1cm-2
bull Dose rate H(10) for Cs-137 01 divide 100 μSvhbull Sensitivity for Cs-137 500 (pulsess-1)( μSvh-1)
Overall dimensions weightbull 50times190times480 mm 10 kgbull Telescopic pole length 07 m
GAMMA-SEARCH BDPG-96MDetector bull Scintillator NaI(Tl) Oslash 18times30 mm
Measurement rangebull Flux density measurement range 10 divide 24000 s-1cm-2
bull Dose rate H(10) for Cs-137 01 divide 300 μSvhbull Sensitivity for Cs-137 200 (pulsess-1)( μSvh-1)
Overall dimensions weightbull Oslash 35times320 mm 05 kgbull Telescopic pole length 07 or 38 m
EXTERNAL PROBES GAMMA
BDVG-96
BDPG-96M
BDPG-96
EXTERNAL PROBESGAMMA BDKG-96 STAINLESS STEEL CASING FOR GEOLOGIC APPLICATIONS WELL LOGGINGDetector bull Scintillator NaI(Tl) Oslash 18times30 mm
Measurement rangebull Flux density measurement range 10 divide 105 s-1cm-2
bull Dose rate H(10) for Cs-137 5 divide 2104 μRhbull Sensitivity for Cs-137 200 (pulsess-1)( μSvh-1)
Overall dimensions weightbull Oslash 38times535 mm 36 kgbull Cable length 10 divide 1000 m
NEUTRON BDMN-96Detector bull Scintillator with ZnS(Ag)
Measurement rangebull Dose rate H(10) 01 μSvh divide 01 Svhbull Dose H(10) 01 μSv divide 10 Sv
Energy range bull 0025 eV divide 10 MeV
Overall dimensions weightbull Detector Oslash 54times200 mm 08 kgbull Moderator Oslash 245 mm 73 kg
NEUTRON-SEARCH BDKN-96Detector bull He-3 counter in polyethilene moderator
Measurement rangebull Dose rate H(10) for Pu-Be 01 μSvh divide 01 Svhbull Dose H(10) for Pu-Be 01 μSv divide 10 Sv
Energy range bull 0025 eV divide 14 MeV
Overall dimensions weightbull 295times142times100 mm 225 kg
BDKG-96M
BDMN-96
BDKN-96
SPC ldquoDozardquoRadiation monitoring equipment
60 61
bull No gas supply neededbull Clothing control detachable right hand detector bull Alpha detector optional connection bull Numeric and color (red green) indication of
control resultsbull LED sensor of hand-foot positioning for start of
measurementbull Automatic compensation of gamma background
and contamination of detectorbull Audible alarm signals of the excess of preset
thresholdsbull Measurement value indication min-1cm-2 or
Bqсm2
Reference standards Nuclear IEC 61098
RZB-05D HAND-FOOT-CLOTHING MONITOR
Physical characteristicsDetectors bull Gamma beta - GM countersbull Alpha - scintillatior ZnS(Ag)
Detecting nuclidesbull Alpha Pu-239 U-234 U-238bull Beta Sr-90+Y-90 F-18 Cs-137 Co-60 Tс-99 O-15
N-13 Sr-89 C-11 I-131 Na-22 Ru-106+Rh-106 Tl-204
bull Gamma Tc-99m I-123
Efficiencybull Alpha
Pu-239 40 U-234 25U-238 15
bull Beta Sr-90 +Y-90 40
Measurement range bull Alpha 1 divide 103 min-1cm-2 bull Beta 10 divide 103 min-1cm-2
bull Gamma 5103 divide 5106 min-1cm-2
Energy range bull Alpha 30 divide 80 MeV bull Beta 008 divide 35 MeV bull Gamma 005 divide 30 MeV
Operation temperature range bull Minus 10 divide +50 ordmС
Electrical characteristicsbull Power supply 220 V 50 Hz
Mechanical characteristicsOverall dimensions weight bull 740times750times1180 mm 45 kg
Versionsbull Withwithout alpha detectorbull Indication (min-1cm-2 ) or (Bqсm2)bull Detectors overall dimensions smbull Hand 178 х 235bull Foot 185 х 436
Whole body contamination monitor RZBA-04-04Mbull No gas supply neededbull Compensation for background gamma radiation
and contamination of detector unitsbull Individual threshold setting for each measure-
ment channelbull Visible and audible alarms ldquoCONTAMINATIONrdquo and
ldquoCLEANrdquo bull Indication of contaminated body parts on the
panel with image of the bodybull Optional remote alpha-detector
Physical characteristicsDetectors bull Beta - GM counters scintillatorsbull Alpha - scintillatior ZnS(Ag)
Measurement range bull Beta 5 divide 15000 min-1cm-2
bull Alpha 01 divide 10000 min-1cm-2
Energy range bull Beta 015 divide 25 MeV bull Alpha 40 divide 56 MeV
Operation temperature range bull +5 divide +50 ordmС
Electrical characteristicsPower supply bull 220 V 50 Hz
Interfaces bull RS-232bull RS-485
Mechanical characteristicsOverall dimensions weight bull 2650times940times930 mm 310 kg
Versionsbull Withwithout alpha detectorbull Indication (min-1cm-2 ) or (Bqсm2)
Reference standards Nuclear IEC 61098
RZBA-04-04MWHOLE BODY CONTAMINATION MONITOR
SPC ldquoDozardquoRadiation monitoring equipment
62 63
RZA-05DALPHA HAND-MONITOR
bull No gas supply needed bull Numeric and color (red green) indication of
control resultsbull LED sensor of hand- positioning for start of
measurementbull Audible alarm signals of the excess of preset
thresholdsbull Measurement value indication min-1cm-2 or
Bqсm2
Physical characteristicsDetectors alpha - scintillatior ZnS(Ag)
Efficiencybull Pu-239 20 bull U-234 14bull U-238 8
Measurement range bull 05 divide 105 min-1cm-2
Energy range bull 41 divide 90 MeV
Operation temperature range bull minus 10 divide +50 ordmС
Electrical characteristicsPower supply bull 220 V 50 Hz
Mechanical characteristicsOverall dimensions weight no more bull 740times1400times1450 mm 70 kg
Reference standards Nuclear IEC 61098
bull Simultaneous measurement of alphabeta activi-ties in the sample
bull Active shielding anti-coincidence background subtraction using GM counters
bull Lead shielding 30 mm
UMF-2000 LOW LEVEL ALPHA- BETA- COUNTER
Physical characteristicsDetectors bull Silicon specrometric detector 500 or 1000 mm2
Measurement range bull Alpha 001 divide 1000 Bq bull Beta 01 divide 3000 Bq
Energy range bull Alpha 35 divide 80 MeV bull Beta 005 divide 35 MeV
Electrical characteristicsPower supply bull 220 V 50 Hz
Interfaces bull RS-232bull USB
Mechanical characteristicsOverall dimensions weight bull 337times286times190 mm 22 kg
Versionsbull Detector area 500 mm2
bull Detector area 1000 mm2
UMF-2000 Detector area 1000 mm2
UMF-2000 Detector area 500 mm2
SpectraDec software for alpha-spectrometric measurements
SPC ldquoDozardquoRadiation monitoring equipment
64 65
DRK DOSE AREA PRODUCT METER
DRK-1bull Diagnostic reference level (DRL) of patients
determinationbull Suitable for all basic types of x-ray machines
Physical characteristicsDetector bull Plane-parallel ionization chamber
Measurement range bull 1 divide 104 cGycm2
Electrical characteristicsPower supply bull 220 V 50 Hz
DRK-1M-CTbull Measuring of dose length product
Physical characteristicsDetector bull Pencil Ionization Chamber
Measurement rangebull 05 divide 109 microGym
DRK-1Mbull Measuring of air kerma on sectional area of the
X-ray beam productbull Measuring of air kerma rate on area productbull Measuring of air kerma ratebull Measuring of air kerma
Physical characteristicsDetector bull Plane-parallel ionization chamber
Measurement rangebull 01 divide 109 microGym2
bull 06 divide 6104 microGym2cbull 30 divide 9105 microGycbull 30 divide 9991011 microGyReference standard IEC 60580 2003
bull Measurement of strontium-90 in the foodstuffs agricultural products etc
bull Measurement of gross beta activity in samplebull Self tests using built-in LED
ldquoPROGRESS-BETArdquo SCINTILLATION BETA SPECTROMETER
Physical characteristicsDetector bull Plastic scintillator Oslash70x10 mm
Sample bull Plate Oslash70 mmbull Weight up to 15 g
Energy range bull 02 divide 30 MeV
Minimum detectable activity of Sr-90 in a 10 g sample on a standard planchet Bqsamplebull In case of absence of K-40 in the sample 01 Bqbull In case the activity of K-40 till 5 Bqg 05 Bq
Electrical characteristics Interface bull USB
Mechanical characteristicsWeight bull No more 50 kg
Complete setBasic complete setbull Detector unit with plastic scintillator integrated
power supply amplifier ADC bull Lead shielding bull ldquoProgressrdquo software bull Сheck source for energetic calibration (Sr-90-Y-90) bull Planchet Oslash 70 mm (5 items) bull Sample dencification device bull Procedure manual for measurement of radio-
nuclidesrsquo activity using the scintillation beta spec-trometer ldquoProgressrdquo
Optional equipment and servicebull Personal computer and printer bull Calibrations for radionuclides not included in the
main library of radionuclides
Progress-Beta
Reference standards IEC 61562
SPC ldquoDozardquoRadiation monitoring equipment
66 67
bull Measurement of gamma activity in foodstuffs soil samples and others environmental objects
bull Identification of radionuclides in the sample bull Automatic correction for sample density bull Self-tests using built-in LED
ldquoPROGRESS-GAMMArdquoSCINTILLATION GAMMA SPECTROMETER
Physical characteristicsDetector bull NaI (Tl) Oslash63times63 mm
Validated measurement geometries bull Marinelli beakers (1 liter) Petri dishes (Oslash90 mm)
etc
Energy range bull 02 divide 30 MeV
Minimum detectable activity Bqsamplebull Cs-137 3 Bqbull Th-232 7 Bqbull Ra-226 8 Bq bull К-40 40 Bq
Electrical characteristics Interface bull USB
Mechanical characteristicsWeight bull No more 120 kg
Complete setBasic complete setbull Scintillation detector unit with NaI (Tl) detector
with integrated power supply amplifier and ADC bull Lead shielding 50 mm bull ldquoProgressrdquo software bull Сheck source for energy calibration (Cs-137 +
K-40)bull Marinelli beakers - 1 liter (5 items) bull Petri dishes Oslash 90 mm (5 items) bull Procedure manual for measurement of activity
of radionuclides using the scintillation gamma spectrometer ldquoProgressrdquo
Optional equipment and servicebull Kit for radon measurements including calibration
of ldquoIC-63rdquo geometry for counting the charcoal samples
bull Personal computer and printer bull Calibrations for user defined geometries bull Calibrations for radionuclides not included in the
main library of radionuclides
Progress-Gamma
Reference standards IEC 61563
ldquoPROGRESS-G(P)rdquoPORTABLE SCINTILLATION GAMMA SPECTROMETERbull Field measurements of gamma activity in environ-
mental objects without sampling (4π geometry)bull Laboratory measurement of gamma activity in
foodstuffs soil samples and others environmental objects
bull Identification of radionuclides in the sample bull Automatic correction for sample densitybull Tests using built-in LED
Physical charachteristicsDetector bull NaI (Tl) Oslash45times50 mmbull Lead shielding 20 mm
Validated measurement geometries bull Marinelli beakers (05 liter) Petri dishes (Oslash90 mm)
etc
Energy range bull 02 divide 30 MeV
Minimum detectable activity in 05-litre Marinelli beaker bull Cs-13710 Bqkgbull К-40100 Bqkgbull Ra-22618 Bqkg bull Th-23216 Bqkg
Minimum detectable activity in 30 min (4π geometry) bull Cs-137 2 Bqkgbull К-40 30 Bqkgbull Ra-226 4 Bqkg bull Th-232 3 Bqkg
Electrical characteristicsPower supply bull Rechargeable batterybull 220 V 50 Hz
Interface bull USB RS-232
Weight bull No more than 60 kg
Complete setBasic complete setbull Scinttillation detector unit with NaI(Tl) bull ldquoProgressrdquo softwarebull Сontrol unit ldquoSputnikrdquo for aquisition and analisys
of spectra with built-in memory for spectral databull Casebull Lead shielding (2 cm) for laboratory usebull 05-litre Marinelli beakers ndash 5 itemsbull Na-22 check sourcebull Power adapter BPS-01bull Operation manualbull Procedure manual for measurement of activity
of radionuclides using the scintillation gamma spectrometer ldquoProgressrdquo
Optional equipment and servicebull Kit for radon measurements with charcoalbull Built-in dose rate meterbull Additional memory (RAM) for storage of 64
spectrabull Additional power adapterbull Notebook and printer
Progress-Gamma
Reference standards IEC 61563
SPC ldquoDozardquoRadiation monitoring equipment
68 69
Physical characteristicsDetectorbull Scintillation detector ZnS (Oslash 60 mm)
Samplebull Thin sample - diameter up to 70 mm bull Preparation technique - electro-depositionbull Thick sample - diameter 70 mm weight
200300 mg bull Preparation technique - application of powders
(prepared by radiochemical concentration by water evaporation or by pounding of mineral samples) onto a planchet with the help of spirit
Energy rangebull 15 divide 8 MeV
Minimum detectable activitybull Thin samples no more than 910-3 Bqsamplebull Thick samples no more than 180 Bqkg
Mechanical characteristicsOverall dimensions weightbull 195times120times210 mm 34 kg
Complete setBasic complete setbull Alpha radiometer ldquoProgress-ARrdquobull Check source (uranium isotopes)
Set of accessoriesbull Procedure manual for measurements of radi-
oactivity using scintillation alpha radiometer ldquoProgress-ARrdquo
bull ldquoProgressrdquo software
ldquoProgress-ARrdquo
bull Measurement of gross activity of alpha emitting radionuclides in thin samples
bull Measurement of gross activity of alpha emitting radionuclides in thick samples
bull Measurement of activity deposited on aerosol filters
ldquoPROGRESS-ARrdquoALPHA RADIOMETER
Several fixed positions of the detector enable to perform measurements in various geometries and to estimate the content ofbull Cs-137 in the whole bodybull I-131 in thyroidbull Co-60 Cs-137 Mn-54 Cr-51 in lungsbull Database for storage of measurement data and
resultsbull Uncertainty calculations based on measurement
databull Self tests using built-in LED
ldquoPROGRESSrdquo WHOLE BODY COUNTER
Physical characteristicsDetectorbull scintillation detector NaI (Tl) Oslash63times63 mm
Energy rangebull 02 divide 28 MeV
Minimum detectable activitybull By Cs-137 in the whole body - 1200 Bqbull By I-131 in thyroid - 100 Bqbull By Co-60 Cs-137 Mn-54 Cr-51 in lungs - 200 Bq
Mechanical characteristicsWeight bull No more than 120 kg
Complete setBasic complete setbull Collimator with rotator and holderbull Detector with incorporated ADCbull Patient chair and table for collimatorbull Check source Na-22bull Procedure manual for lifetime measurement of
gamma-emitting radionuclidesrsquo activity in human body using the gamma-spectrometer of human radiation ldquoProgressrdquo
bull laquoProgressraquo software
Optional equipment and servicebull Program of internal radiation committed internal
radiation effective dose calculation by the stand-ard model
bull Background phantombull Personal computer and printer
Collimator with rotator and holder
SPC ldquoDozardquoRadiation monitoring equipment
70 71
bull Categorization of wastes for the purpose of fur-ther processing including wastes with unknown radionuclide composition
bull Measurements during the incoming waste inspec-tion (accepting for storage disposal)
bull Certification of unconditioned and conditioned wastes in closed containers without opening them (at nuclear plants or at facilities providing collection storage transportation conditioning processing temporal storage and final disposal of radioactive waste)
bull Activity measurement of extended objects in situ without opening the equipment
bull Activity measurement of extended objects after opening (for example assessment of tubes used for oil transportation)
MKG-01D ldquoSADOVNIKrdquoSPECTROMETRY SYSTEM
Physical charachteristicsDetectorbull Detector unit GEM (GMX) with HPGe detector and
multi-positioning cryostat CFG-PMOD4-7 with 7 litre Dewar
bull Dose rate probe BDMG-200
Energy range bull With GEM detector 004 divide 30 MeVbull With GMX detector 0005 divide 15 MeVbull Dose rate probe BDMG-200 ndash 005 divide 30 MeV
Measurement rangebull 110-7 divide 10 Svhbull Relative efficiency of detection (in photopeak) at
13325 MeV (Co-60) 10 divide 150
Electrical characteristicsPower supplybull 220 V 50 Hz
Interfacebull USB
Complete setBasic complete setbull Spectrometric detector unit GEM (GMX) with
HPGe detector and multi-positioning cryostat with 7 litre Dewar
bull Portable digital multichannel analyzer DigiDARTbull Dose rate probe BDMG-200bull Autonomous power supply unit with built-in
batterybull Industrial computer keyboardbull Laser range-finderbull Thermographic printerbull Web-camerabull Device equipped with stepper motor for position-
ing of the spectrometric detectorbull Calibration device with reference sources
(Am-241 Co-60 Ba-133 Eu-152) for energy calibration
bull Removable collimators with end capbull Measurement proceduresbull ldquoClasterrdquo software
bull Measurement of gross alpha activity of alpha-emitting radionuclides
bull Measurement of alpha-emitting radionuclides activity in thin-layer samples meeting alpha-spectrometry requirements
Physical characteristicsDetectorbull Silicon ion-implanted 450 mm2
bull Easy to decontaminate thin windowbull dead layer less than 015 μmbull Background count rate in the range 3 divide 9 MeVbull No more than 09 h-1cm-2 for 450 mm2 detector
Energy rangebull 2 divide 9 MeVbull Lower limit of measurement range (minimum
detectable activity) 01 Bqbull Background count rate no more than 100 counts
in 24 hours
Electrical characteristics Power supplybull 220 V 50 Hz
Interfacebull USB
Complete setBasic complete setbull Detector unit with vacuum measuring chamber
and vacuum control systembull Low noise vacuum pump (type 2FY-05B or
equivalent)bull Check sourcebull ldquoProgressrdquo softwarebull Vacuum tube
MKS-01A ldquoMULTIRAD-ASrdquoALPHA SPECTROMETER
SPC ldquoDozardquoRadiation monitoring equipment
72 73
UCRV-2AIRFLOW MONITOR
bull Monitor of the air flow through filter of centralized multichannel sampling system
bull Radiation monitoring system (RMS) integration for internal exposures determination
bull Volume and flow rate measurements of the air that have passed through a analytical filter
bull Bar-code for filter identificationbull Operation as either standalone unit or as a part of
the RMS
Physical characteristicsMeasurement range of air volume bull 001 divide 9999 m3
Operation temperature range bull minus 20 divide +50 ordmС
Electrical characteristicsPower supply bull 220 V 50 Hz
Interface bull RS-485
PVP-06PORTABLE AIR SAMPLER
Air Sampler PVP-06 is indispensable for monitoring the radiation situation where the concentration of radioactive aerosols in the air does not require a sta-tionary sampling equipment Sampling head PVP-06 provides easy change of filters and cartridges
Purposebull To monitor the concentration of radioactive aero-
sols in the air sites
Controlled aerosolsbull Alpha- and beta-active aerosolsbull Daughter products of decay of radon and thoronbull Iodine isotopes
Physical characteristicsTypes of filtersbull Aerosol AFA-RSP-20bull Iodine AFA SI-20
Flow rate bull 33∙10-4 ndash 233∙10-4 m3s (20 divide 140 l min)
Electrical characteristicsPower supply bull 220 V50 Hzbull The vehicle power supply 108 divide 145 Vbull Internal battery
Minimal working time on internal battery to recharge bull 8 hours
Power consumption (at a flow rate of 100 lmin) bull 40 VA
Environment characteristicsOperating temperature bull minus 10 divide +40 deg C
Maximum humidity bull 90
Pressure bull 860 to 1060 hPA
Noise generated by the pump bull lt 55 dBA at 1 m
Mechanical characteristicsDimensions weight bull 241 times 108 times 160 mm 28 kg
Case material bull Plastic
Complete setbull Air sampler PVP-06bull AC power adapterbull Filters AFA-RSP-20 - 100 pcsbull Packaging for filters - 40 pcsbull Casebull Operation manualbull Calibration certificate
Optional equimpient bull Kit for sampling sorption columns of activated
carbon Ř head of sorption columns with protective
covers Ř activated charcoal SKT-3 - 1 pkg (02 L) Ř charocoal samples SC-13 - 8 pcs
bull Car charger bull Tipod bull Shoulder strapbull Calibration stand bull Filters AFA SI-20 - 100 pcs
Consumablesbull Aerosol filters AFA RSP-20bull Iodine filters AFA SI-20
SPC ldquoDozardquoRadiation monitoring equipment
74 75
Calibration of gamma dose and dose rate meters
Calibration ofbull Ambient equivalent dose H(10) meters (Sv Svh)bull Personal equivalent dose Hp(10) meters (Sv Svh)bull Exposure dose X meters (R Rh)bull Two sources in irradiator bull Select source and collimator opening using
tumbler
UPG-P DESKTOP GAMMA BEAM IRRADIATOR
Physical characteristicsRange of reproduced dose rate bull 05 μSvh divide 10 mSvh (50 μRh divide 100 mRh)
Sources activities bull 6times106 6times108 Bq (02 20 mCi) Cs-137
Overall dimensions bull 1250times400times300 mm
Irradiator weight bull Not more than 37 kg
Calibration bench weight bull Not more than 15 kg
Reference standards IEC 60846 IEC 61526
Physical characteristicsDetectorbull Silicon
Measurement range EEC measurement bull Measurement range of radon EEC
10 divide 10bull106 Bqbullm-3
bull Measurement range of thoron EEC 05 divide 10bull104 Bqbullm-3
bull Air flow through the filter 100plusmn05 lmin
Concentration measurementbull Measurement range of radon-222 concentration
in air 10 divide 20bull106 cpsbull Measurement range of 216Po(ThA)
1bull10-3 divide 1bull102 cpsbull Air sampler flow rate
10plusmn02 lminbull Measurement range of radon-222 concentration
in water samples 6 divide 800 Bqbullkg-1
bull Measurement range of radon-222 flux from soil surface 20 divide 103 mBqsbullm2
bull Measurement range of radon-222 concentration with preliminary sampling of air using air sam-plers 20 divide 107 Bqbullm-3
bull Measurement range of radon-222 concentration in samples of soil air 103 divide 106 Bqbullm-3
Operation temperature range bull 1 divide 35 ordmC
Electrical characteristicsPower supply bull 80 VA
Mechanical characteristicsOverall dimensions weight bull 220times200times165 mm 36 kg
ldquoALPHARAD PLUSrdquoRADON THORON amp THEIR PROGENY MONITORbull Measurement of radon and thoron concentration
and effective equivalent concentration (EEC)bull In the airbull In the indoor air of residential public and industri-
al buildings and structuresbull Measurement of radon in drinking water sourcesbull Measurements of radon flux from the soil surface
at land plots allocated for construction of houses public buildings and industrial facilities
bull Measurements of radon concentration in soil air
Reference standards IEC 61577
SPC ldquoDozardquoRadiation monitoring equipment
76 77
UKPN-2M-D NEUTRON BEAM IRRADIATOR
Reference standards IEC 61005 61322
Calibration of neutron dose and dose rate meters
Calibration ofbull Ambient equivalent dose H(10) meters (Sv Svh)bull Personal equivalent dose Hp(10) meters (Sv Svh)bull Flux density of neutrons (cm-2∙s-1)bull Transfer container for temporary storage of
sources bull Red light signal of source working position
Physical carachteristicsRange of reproduced dose ratebull 20 divide 800 μSvh
Range of reproduced flux densitiesbull 10 divide 400 cm-2∙s-1
Type of a source in use bull Pu-Be
Activity of a source in usebull 24х1011 Bq (with density of 107 s-1)
Overall dimensions weight no morebull 3000x750x2000 mm 300 kg
Required room dimensionsbull not less than 7x3x3 m
Electrical characteristicsPower supply bull 220 V 50 Hz
Calibration of gamma dose and dose rate meters
Calibration ofbull Ambient equivalent dose H(10) meters (Sv Svh)bull Personal equivalent dose Hp(10) meters (Sv Svh)bull Exposure dose X meters (R Rh)bull Four sources in irradiator bull Select source and move to working position
return to storage position using special rodbull Transfer container for temporary storage of
sources bull Red light signal of source working position
UPGD-2M-DGAMMA BEAM IRRADIATOR
Physical characteristicsRange of reproduced dose rate bull 05 μSvh divide 50 mSvh (50 μRh divide 5 Rh)
Maximum activity of source bull 2times1011 Bq (50 Ci) Cs-137
Overall dimensionsbull Irradiator 800times500times500 mmbull Guide rails length 30 mbull Height 16 mbull Weight not more than 700 kgbull Required room dimensions not less than 7x3x3 m
Electrical characteristicsPower supply bull 220 V 50 Hz
UPGD-2M-D
Reference standards IEC 60846 IEC 61526 IEC 61066
SPC ldquoDozardquo
78 79
Contents
MEASURING UNITS
DBG-S11D wide range gamma area monitor 40
UDKS-100 gamma and X-ray area monitor 41
UDMN-100 neutron area monitor 41
ALARM UNITS
BAS-2 ldquoMICROrdquo external visual alarm 42
BZS-2 ldquoMicrordquo external audible alarm 42
Illuminated warning signs 43
ldquoImpulsrdquo external display unit 43
UIM-3D area monitor count rate meter 44
DKG-05D personal gamma dosimeter 46
DVS-02D gamma-neutron personal electronic dosimeter 47
DVGI-8D new pen-type personal ionization chamber dosimeters 48
DKG-02U ldquoARBITERrdquo wide range gamma-dosimeter 49
DKG-07D ldquoDROZDrdquo gamma-dosimeter 50
MKS-15D ldquoSNEGIRrdquo multi ndash purpose radiation survey meter 51
SRPS-05D gamma monitor 52
DOZA-TLD multipurpose TLD system 53
DKS-96 universal radiation survey meter 54
EXTERNAL PROBES ALPHA
Alpha BDZA-96 55
Alpha BDZA-96B 55
Alpha BDZA-96M 55
Alpha BDZA-96S 55
Alpha BDZA-96T 55
EXTERNAL PROBES BETA
Beta BDZB-96 56
Beta BDZB-99 56
Beta BDZB-96B 56
Beta BDZB-96S 56
EXTERNAL PROBES GAMMA
Gamma BDKS-96B 57
Gamma and beta BDKS-96S 57
Gamma BDMG-96 57
EXTERNAL PROBES GAMMA
Gamma-search BDVG-96 58
Gamma-search BDPG-96 58
ContentsRadiation monitoring systemldquoPELIKANrdquo Radiation monitoring system (RMS) 6
BDMG-101 high range gamma area monitor 10
DBG-S11D wide range gamma area monitor 11
BDRG-52 high range gamma area monitor for accident and post-accident conditions 12
UDGP-01 Liquid technological environments monitor 13
UDMN-100 neutron area monitor 14
UDKG-100 Wel Liquid gamma monitor 14
BOP-1M data processing and transmission unit 15
UDA-1AB particulate monitor 16
UDG-1B noble gas monitor 17
UDG-03D noble gas monitor 18
UDI-1B iodine monitor 19
UDGB-01 noble gasesH-3C-14 monitor 20
UDGP-01 steam generator leakage monitor 21
UPPVM air flow parameters monitor 22
ldquoIMPULSrdquo external display unit 23
BI-2 remote display amp alarm unit 24
BASBAS-1s external alarm 25
SKGAV stack monitor 26
RMS software 28
RMS workstation ndash operator console 29
Configurator software 29
RM RACK radiation monitoring rack 30
SRKS-01D criticality accident alarm system 32
ldquoATLANT-Mrdquo environmental radiation monitoring system 34
ldquoBREEZErdquo high-volume air sampler 35
ldquoGAMMA-SENSORrdquo gamma-survey system 36
Radiation monitoring equipmentAREA MONITOR ldquoFREGATrdquo 38
BPI-1D local display unit 39
80
Gamma-search BDPG-96M 58
Gamma BDKG-96 stainless steel casing for geologic applications well logging 59
EXTERNAL PROBES NEUTRON
Neutron BDMN-96 59
Neutron-search BDKN-96 59
RZB-05D Hand-foot-clothing monitor 60
RZBA-04-04M whole body contamination monitor 61
RZA-05D alpha hand-monitor 62
UMF-2000 low level alpha- beta- counter 63
DRK dose area product meter 64
ldquoPROGRESS-BETArdquo scintillation beta spectrometer 65
ldquoPROGRESS-GAMMArdquo scintillation gamma spectrometer 66
ldquoPROGRESS-G(P)rdquo portable scintillation gamma spectrometer 67
ldquoPROGRESS-ARrdquo alpha radiometer 68
ldquoPROGRESSrdquo whole body counter 69
MKG-01D ldquoSADOVNIKrdquo spectrometry system 70
MKS-01A ldquoMULTIRAD-ASrdquo alpha spectrometer 71
UCRV-2 airflow monitor 72
PVP-06 portable air sampler 73
ldquoALPHARAD PLUSrdquo radon thoron amp their progeny monitor 74
UPG-P desktop gamma beam irradiator 75
UPGD-2M-D gamma beam irradiator 76
UKPN-2M-D neutron beam irradiator 77
36
Radiation Monitoring Equipment
bull Localization of radioactive contaminationsbull Database with dose rate contaminations
spectra measurement date amp time coordi-nates
bull Work as part of mobile laboratory or as part of Environmental Radiation Monitoring System with real-time data transfer
Physical characteristicsDetector bull Scintillation NaI (Tl) GM counters
Measurement rangebull 01 ndash 107 μSvh
Energy range bull 005 ndash 3 MeV
Operation temperature range bull minus 10 divide +50 ordmС
Electrical characteristics bull Power supply 220 V 50 Hz
ldquoGAMMAndashSENSORrdquoGAMMA-SURVEY SYSTEM
SPC ldquoDozardquoRadiation monitoring equipment
38 39
AREA MONITOR ldquoFREGATrdquoArea Monitor ldquoFregatrdquo is designed for building rela-tively simple and inexpensive radiation monitoring systems at such facilities as radionuclide sources storage areas isotope products warehouses nuclear medicine departments PET centers calibration laboratories where sources of ionizing radiation are used etc
Small scale automated radiation monitoring systems built with ldquoFregatrdquo components featuring audible and visual alarms are matched suitable to meet the regulatory radiation safety requirements
Area monitor ldquoFregatrdquo requires virtually no adjust-ment it is simple and convenient for installation and operation
BPI-1D LOCAL DISPLAY UNIT
Display of monitored parameters values received from external measuring devices
Purposebull Processing and display of values of monitored
parameters on information panel bull Comparison of values of monitored parameters
with thresholdsbull Transfer of monitored parametersrsquo values to
networkbull Generation of alarm in case of exceeding of preset
thresholds including external alarm devices
FeaturesTesting the unit and connected devicesbull Visually on the panelbull Using adjustment software when connected to
PC via USB
Automatic self-testing
The panel displays the following informationbull Diagnostic information about the status of con-
nected devicesbull Current date and timebull Values of measured parametersbull Position of measured values with respect to the
thresholds in the form of scales with green yellow and red zones
bull Time history (trend) for each measured value
Physical characteristicsTemperature range bull minus 10 divide + 50 ordmC
Maximum number of connected devicesbull measuring devices 15bull external audible and visual alarm 15
Display diagonal bull 152 cm (6)
Electrical characteristicsbull Interfaces RS-485bull Power supply 220 V 50 Hz 12 divide 24 V
Mechanical characteristicsbull Protection index IP54bull Paint decontaminable
Overall dimensions weightbull 296x248x118 mm 5 kg
DBG-S11D wide range gamma area monitor
UDMN-100 neutron area monitor
Ethernet RS-485
UDKS-100 gamma and X-ray area monitor
BPI-1D Local display unit
BAS-2 ldquoMicrordquo external visual alarm
BZS-2 ldquoMicrordquo external audible alarm
ldquoImpulsrdquo external display unit
Service workstation
Illuminated warning signs
SPC ldquoDozardquoRadiation monitoring equipment
4140
Continuous automatic monitoring of the gamma- X-ray ambient dose equivalent rate
Physical characteristicsbull Detector tissue-equivalent plastic scintillator
Oslash 45times20 mm
Measurement range bull Dose rate measurement range 01 μSvh divide 1 Svh bull Energy range 0015 divide 10 MeV
Mechanical characteristicsbull Protection index IP65bull Paint decontaminable
Overall dimensions weightbull Oslash72times265 mm 15 kg
UDKS-100 GAMMA AND X-RAY AREA MONITOR
UDMN-100 NEUTRON AREA MONITOR
Physical characteristicsbull detector ndash scintillator ZnS(Ag) Li-6
Measurement range bull 01 μSvh divide 01 Svh
Energy range bull 0025 eV divide 100 MeV
Temperature range bull minus 45 divide +50 ordmC
Electrical characteristicsbull Interfaces RS-485
Mechanical characteristicsbull Protection index IP 65bull Paint decontaminable
Overall dimensions weight bull 428times258times347 mm 115 kg
Continuous automatic monitoring of the neutron-radiations ambient dose equivalent ratebull Spherical polyethylene moderator Oslash 239 mm
MEASURING UNITS
DBG-S11D WIDE RANGE GAMMA AREA MONITOR
Continuous automatic monitoring of the gamma- ambient dose equivalent rate
Physical characteristicsbull Detector ndash GM counters
Measurement rangebull DBG-S11D 01 μSvh divide 10 mSvhbull DBG-S11D-01 01 μSvh divide 10 Svhbull DBG-S11D-02 01 μSvh divide 100 Svh
Energy rangebull 005 divide 30 MeV
Temperature range bull minus 40 divide +50 ordmC
Electrical characteristicsbull Interfaces RS-485 USB
Mechanical characteristicsbull Protection index IP 68bull Paint decontaminable
Overall dimensions weightbull DBG-S11D Oslash 68times141 mm 065 kg bull DBG-S11D-01 Oslash 68times179 mm 07 kgbull DBG-S11D-02 Oslash 68times179 mm 07 kg
Versionsbull DBG-S11Dbull DBG-S11D-01bull DBG-S11D-02
Reference standards Nuclear IEC 60846 IEC 60532 EMC IEC 61010 IEC 61000-6-2 Seismic IEC 60980
SPC ldquoDozardquoRadiation monitoring equipment
4342
ALARM UNITS
Generation visual signals of the excess of preset thresholds
Physical characteristicsLength of communication cablebull up to 1200 mbull Alarm Visual alarm green yellow red
Electrical characteristicsbull Power supply +12 V
Mechanical characteristicsbull Protection index IP 23
Overall dimensions weight 160times84times41 mm 02 kg
BAS-2 ldquoMICROrdquo EXTERNAL VISUAL ALARM
Generation audible signals of the excess of preset thresholds
Physical characteristicsLength of communication cablebull up to 1200 mbull Audible alarm 80 divide 100 dB at a distance of 1 m
Electrical characteristicsbull Power supply +12 V
Mechanical characteristicsbull Protection index IP 23
Overall dimensions weight 160times84times41 mm 02 kg
BZS-2 ldquoMICROrdquo EXTERNAL AUDIBLE ALARM
Physical characteristicsLength of communication cablebull up to 1200 m
Electrical characteristicsbull Power supply 220 V 50 Hz
Mechanical characteristicsbull Protection index IP 23
Overall dimensions weight bull 330times110times20 mm 05 kg
Physical characteristicsLength of communication cablebull up to 1200 m
Character height bull ldquoImpuls-910-Rrdquo 100 mmbull ldquoImpuls-915-D4Srdquo 150 mmbull ldquoImpuls-927-D4Srdquo 270 mm
Operating temperature rangebull ldquoImpuls-910-Rrdquo 0 divide +50 degCbull ldquoImpuls-915-D4Srdquo ldquo-727-D4Srdquo minus 40 divide +50 degC
Electrical characteristicsbull Power supply 220 V 50 Hz
Mechanical characteristicsProtection index bull ldquoImpuls-910-R IP 44bull ldquoImpuls-915-D4Srdquo ldquo-727-D4Srdquo IP 65
Overall dimensions weight bull ldquoImpuls-910-Rrdquo 400times160times60 mm 3 kgbull ldquoImpuls-915-D4Srdquo 815times250times80 mm 5 kgbull ldquoImpuls-927-D4Srdquo 1250times330times80 mm 5 kg
ILLUMINATED WARNING SIGNS
ldquoIMPULSrdquo EXTERNAL DISPLAY UNIT
SPC ldquoDozardquoRadiation monitoring equipment
4544
Individual threshold setting for each measurement channel
Continuous area and process monitoring
Collect amp display data from two measurement chan-nels (units with RS-485 or analog pulses)
Audible and visual alarms on exceeding preset thresholds or status of connected devices
Individual threshold setting for each measurement channel
Switching on the external alarm or executive devices when any threshold is exceeded
The wide panel displays the following information bull Values of measured parameters as min-1∙cm-2
s-1∙cm-2 μSvhbull Diagnostic information about the status of con-
nected devicesbull Current date and timebull Position of measured values with respect to the
thresholds in the form of scales with green yellow and red zones
bull Time history (trend) for each measured value
Physical characteristics Measurement range bull Count rate up to 107 CPM (170 kHz)
Operating temperature range bull minus 20 divide +50 ordmC
Electrical characteristics bull Power supply 220 V bull Interfaces USB
Mechanical characteristics bull Protection index IP 65 bull Overall dimensions weight 222times164times73 mm
40 kg
UIM-3D AREA MONITOR COUNT RATE METER
Measurement of alpha radiation flux density
Detector unit BDZA-100 (70 cm2) Measurement range 01 divide 104 min-1∙cm-2
Detector unit BDZA-100B (300 cm2) Measurement range 01 divide 2103 min-1∙cm-2
Measurement of beta radiation flux density
Detector unit BDZB-100 (28 cm2) Measurement range 10 divide 105 min-1∙cm-2
Detector unit BDZB-100L (30 cm2) Measurement range 10 divide 104 min-1∙cm-2
Detector unit BDZB-11D (84 cm2) Measurement range 5 divide 15∙104 min-1∙m-2
OPTIONAL PROBESMeasurement of gamma radiation flux density
Detector units BDEG-03 Measurement range 4 divide 2000 s-1∙cm-2
Detector unit UDKG-100 for operation in the rocks ore liquid media and sludge Measurement range 40 divide 8000 s-1∙cm-2
Measurement of the ambient dose equivalent rate
Detector unit DBG-S11D Measurement range 01 μSvh divide 100 Svh
Measurement of neutron radiation ambient dose equivalent rate
Detector unit BDMN-100 Measurement range 01 μSvh divide 01 Svh
SPC ldquoDozardquoRadiation monitoring equipment
46 47Reference standards Nuclear IEC 61526
Measurement of gamma-radiation personal dose equivalent Hp(10)bull Stand-alone dosimeter or composed of dosimetric
system onebull Audible and visual alarmbull Large memory dose accumulation historiesbull Exclusion of unauthorized intervention in dosim-
etry operation
DKG-05D PERSONAL GAMMA DOSIMETER
Physical characteristicsDetectors bull Silicon
Measurement range bull Dose rate 1 μSvh divide 10 Svhbull Dose 01 μSv divide 15 Sv
Energy range bull 005 divide 30 MeV
Electrical characteristicsbull Power supply rechargeable NiMH battery 1
alcaline battery (type AAA)
Operation timebull Till recharging not less 400 hoursbull With one set batteries not less 1000 hours
Mechanical characteristicsOverall dimensions weight bull 47times26times87 mm (with clip) 70 g
Environmental characteristicsbull IP65bull Temperature range minus 20 divide +45 ordmCbull Humidity up to 98 at 35 ordmCbull Shock vibration and drop resistant
Alarmbull Excess of alarm thresholdsbull Warnings of self-test failure and battery discharge bull Audible alarm 80 dB at 40 cmbull Visual alarm blinking LED
Relative equipmentbull One dosimeter charger ZU-1Mbull Chargestorage cassetes KZU-28KZU-56bull ldquoSmart chargingrdquo feature extends battery life timebull DKG-05D reader US-05bull DKG-05D system reader DVS-01D
Reader-PC interfacebull US-05 USB bull DVS-01D Ethernet
KZU-28
Physical characteristicsDetectors bull Silicon Li-6
Gamma measurement range bull Dose rate 1 μSvh divide 10 Svhbull Dose 01 μSv divide 15 Sv
Gamma energy range bull 005 divide 60 MeV
Neutron measurement range bull Dose rate 1 μSvh divide 2 Svhbull Dose 20 μSv divide 15 Sv
Neutron energy range bull 0025 eV divide 20 MeV
Electrical characteristicsPower supply bull Rechargeable NiMH batterybull Operatiion time till recharging not less 200 hours
Mechanical characteristicsOverall dimensions weight bull 47times26times87 mm (with clip) 70 g
Environmental characteristicsbull IP65bull Temperature range minus 20 divide +40 ordmCbull Humidity up to 75 at 30 ordmCbull Shock vibration and drop resistant
Alarmbull Excess of alarm thresholds bull Warnings of self-test failure and battery discharge bull Audible alarm 80 dB at 40 cmbull Visual alarm blinking LED
Relative equipmentbull One dosimeter charger ZU-1Mbull Chargestorage cassetes KZU-28 KZU-56bull ldquoSmart chargingrdquo feature extends battery life timebull DVS-02D reader UZS-01Sbull DVS-02D system reader DVS-01D
Reader-PC interfacebull UZS-01S USB bull DVS-01D Ethernet
UZS-01DReference standards Nuclear IEC 61526
DVS-02D GAMMA-NEUTRON PERSONAL ELECTRONIC DOSIMETER
Measurement of gamma- and neutron radiations personal dose equivalent Hp(10)bull Stand-alone dosimeter or composed of dosimetric
system onebull Audible and visual alarmbull Large memory dose accumulation historiesbull Exclusion of unauthorized intervention in dosim-
etry operationbull Both albedo thermal neutrons and intermediate
fast neutrons registrationbull Usable in the fields of Pu(Be) Po(Be) Cf and other
neutron sources as well as near nuclear reactors without neutron spectrum estimation
SPC ldquoDozardquoRadiation monitoring equipment
48 49
Dosimeters DVG-03D
DVGI-8D NEW PEN-TYPE PERSONAL IONIZATION CHAMBER DOSIMETERS
Measurement of personal dose equivalent Hp(10) of gamma and X-ray radiationbull Hp(10) of continuous and pulsed gamma and
X-ray radiation bull Electronic reader KSU-1bull Dosimeter DVG-03D with electronic ID bull Personal dose histories in the readerrsquos memorybull Readerrsquos connection with PC for database main-
tenance
Physical characteristicsDetector bull Ionization chamber
Measurement range bull 001 mSv divide 25 mSv
Energy range bull 0015 divide 25 MeV
Temperature range bull Reader KSU-1 +10 divide +50 ordmСbull Dosimeter DVG-03D minus 40 divide +50 ordmС
Electrical characteristicsPower supply bull Reader KSU-1 220 V 50 Hz built-in batteries bull Dosimeter DVG-03D four batteries CR 1025 bull Batteries life 3 yearsbull Readers interfaces RS-232USB 20
Mechanical characteristicsOverall dimensions weightbull Dosimeter DVG-03D Oslash 18times126 mm 005 kgbull Reader KSU-1 235times232times125 mm 28 kg
Reference standards Nuclear IEC 62387-1
DKG-02U ldquoARBITERrdquo WIDE RANGE GAMMA-DOSIMETER
Physical characteristicsDetectors bull GM counters
Measurement rangebull Dose-rate 01 μSvh divide 3 Svhbull Dose 1 μSv divide 100 Sv
Energy range bull 005 divide 3 MeV
Electrical characteristicsbull Power supply 2 alcaline batteries (type AA)bull Batteries life not less 200 hours
Mechanical characteristicsOverall dimensions weight bull 152times82times32 mm 03 kg
Environmental characteristicsbull Temperature range minus 20 divide +50 ordmCbull Humidity up to 90 at +25 ordmCbull Shock vibration and drop resistant
Reference standards Nuclear IEC 60846
Measurement of gamma radiation ambient equiva-lent dose H(10) and dose rate H(10)bull Audible signals (clicks) for radiation condition
estimationbull Analog scale for search modebull Audible and visual alarms of the excess of preset
dose and dose rate thresholds bull Shock-resistant water-proof easy decontamina-
tion casebull 100 measurement results memory with date and
time of measurementbull Indication of total dose accumulated during
exploitation time bull Indication of measurement result statistical
uncertainty
SPC ldquoDozardquoRadiation monitoring equipment
50 51
Physical characteristicsDetectors bull GM counter
Measurement rangebull Dose-rate 01 μSvh divide 3 mSvhbull Dose 1 μSv divide 02 Sv
Energy range bull 005 divide 3 MeV
Temperature range bull Minus 20 divide +50 ordmC
Electrical characteristicsbull Power supply 2 alcaline batteries 15 V (type AA)bull Batteries life not less 200 hours
Mechanical characteristicsOverall dimensions weight bull 122times74times29 mm 025 kg
Reference standards Nuclear IEC 60846
DKG-07D ldquoDROZDrdquoGAMMA-DOSIMETER
Measurement of gamma radiation ambient equiva-lent dose H(10) and dose rate H(10)bull Two independent measurement channels dose
and dose ratebull Audible signals (clicks) for radiation condition
estimationbull Continuous measurement with updating meas-
urement resultbull Measurement result can be obtained with any
desired statistical uncertainty (error)bull Automatic restart when radiation level sharply
changesbull Indication of statistical uncertainty (error) during
measurement process
Continuous measurement with updating measure-ment result
Automatic restart when radiation level sharply changes bull Gamma dose H(10) and dose-rate H(10) meas-
urementbull Beta and gamma contamination surveybull Indication of statistical uncertainty during the
measurementbull Continuous measurement with accuracy increas-
ing with time bull Automatic restart triggered by change of gamma
dose-ratebull Compensation of gamma count rate while meas-
uring beta radiationbull Indication of battery charge levelbull Audible signal of the excess of preset threshold
Physical characteristicsDetectors bull GM counter
Measurement range bull Dose-rate 01 microSvh divide 20 mSvhbull Dose 1 microSv divide 100 Svbull Beta flux density (for Sr-90+Y-90)
10 divide 105 cm-2 min-1
Energy range bull Gamma 005 divide 3 MeVbull Beta 01 divide 3 MeV
Temperature range bull Minus 20 divide +50 ordmC
MKS-15D ldquoSnegirrdquo backside
MKS-15D ldquoSNEGIRrdquoMULTI ndash PURPOSE RADIATION SURVEY METER
Reference standards Nuclear IEC 60846 IEC 60325
Electrical characteristicsbull Power supply 2 alcaline batteries (type AA)bull Battery life not less 400 hours
Mechanical characteristicsOverall dimensions weight bull 124times72times35 mm 035 kg
SPC ldquoDozardquoRadiation monitoring equipment
52 53
Physical characteristicsDetectorbull GM counter
Measurement range bull 01 μSvh divide 20 mSvh
Energy range bull 005 divide 30 MeV
Threshold setting range bull 03 μSvh divide 20 mSvh
Step change of the thresholdbull In the range 03 divide 10 μSvh with the step
001 μSvhbull In the range 10 divide 100 μSvh with the step
01 μSvhbull In the range 100 divide 2000 μSvh with the step
10 μSvh
Electrical characteristicsPower supply bull 220 V 50 Hz bull Relay output
Mechanical characteristicsProtection index bull IP 40
Overall dimensions weight bull 226times120times75 mm 07 kg
Alarmbull Sound alarm 80 divide 100 dBA at distance 1 mbull Visual alarm redbull Connection of the external alarm signaling unit
Reference standards Nuclear IEC 60846 IEC 60532
Continuous automatic monitoring of the ambient dose equivalent rate bull Measurement of gamma dose rate H(10)bull Audible and visual alarm signals for preset
thresholdsbull Switching on the external signaling or executive
devices
SRPS-05D GAMMA MONITOR
Measurement ofbull Gamma and X-ray personal dose equivalent
Hp(10)bull Neutron personal dose equivalent Hp(10)bull Lens dose equivalent Hp(3)bull Skin dose equivalent Hp(007)bull TLD reader day-to-day tests using built-in LEDbull No needs nitrogen for heating
Physical charachteristicsDetectors bull 7LiF Mg Ti (gamma beta)bull 6LiF Mg Ti (neutron)
Gamma and X-ray Hp(10) Measurement range bull 500 μSv divide 10 Sv
Energy range bull 0015 divide 30 MeV
Neutron Hp(10)Measurement range bull 01 mSv divide 100 mSv
Energy range bull 0025 eV divide 10 MeV
Beta and photons Hp(007) Hp(3) Measurement range bull 2 mSv divide 100 Sv
Energy range bull Beta 025 divide 35 MeVbull Photons lt15 keV
Mechanical characteristicsDosimeters overall dimensions weight bull Gamma Hp(10) DTL-2 holder - 62times26times16 mm
16 gbull DTU holder - 42times28times18 mm 8 gbull Lens Hp(3) face skin Hp(007) Oslash 32times16 mm 9 gbull Finger skin Hp(007) 90times20times2 mm 1 gbull Neutron gamma Hp(10) 48times40times20 mm 30 g
Reference standards Nuclear IEC 61066
DTL-2 DTU-2
MKD (A-type) DVNG-M
DOZA-TLD MULTIPURPOSE TLD SYSTEM
SPC ldquoDozardquoRadiation monitoring equipment
54 55
Continuous and pulsed gamma and X-ray dose H(10) and dose-rate measurementbull Alpha beta and gamma contamination surveybull Neutron dose H(10) and dose-rate measurementbull Gamma radiation flux density in boreholes and
liquid media measurement
Electrical characteristicsPower supply bull UIK-05 four C-size batteriesbull UIK-05-01 rechargeable batterybull UIK-06 rechargeable battery
Interfaces bull RS-232bull USB (via adapter)
bull Detector type automatic determination and corre-sponding measurement modes selection
bull Alarm threshold settings ndash for dose dose-rate alpha and beta contaminations
bull ldquoDetectrdquo and ldquoLocaterdquo modes for survey probes
Reference standards Nuclear IEC 60846 IEC 60325 IEC 61005 IEC 62363
Case
UIK-06 control unit165times78times48 mm 03 kg
DKS-96UNIVERSAL RADIATION SURVEY METER
UIK-05 control unit202times86times90 mm 10 kg
BDZA-96
BDZA-96B
BDZA-96M
BDZA-96S
BDZA-96T
EXTERNAL PROBES ALPHAALPHA BDZA-96Detector bull ZnS(Ag) 70 cm2
Measurement range (for Pu-239)bull 01 divide 104 min-1cm-2
Overall dimensions weightbull Oslash 130times240 mm 11 kg
ALPHA BDZA-96BDetector bull ZnS(Ag) 300 сm2
Measurement range (for Pu-239)bull 01 divide 2103 min-1cm-2
Overall dimensions weightbull Oslash 230times290 mm 40 kg
ALPHA BDZA-96MDetector bull ZnS(Ag) 10 сm2
Measurement range (for Pu-239)bull 01 divide 105 min-1cm-2
Overall dimensions weightbull Oslash 65times240 mm 09 kg
ALPHA BDZA-96SDetector bull ZnS(Ag) 30 сm2
Measurement range (for Pu-239)bull 01 divide 5104 min-1cm-2
Overall dimensions weightbull Oslash 90times240 mm 10 kg
ALPHA BDZA-96TDetector bull Silicon 5 сm2
Measurement range (for Pu-239)bull 01 divide 106 min-1cm-2
Overall dimensions weightbull Oslash 50times60 mm 015 kg
SPC ldquoDozardquoRadiation monitoring equipment
56 57
BETA BDZB-96Detector Scintillator 28 сm2
Measurement range (for Sr-90+Y-90)bull 10 divide 105 min-1cm-2
Energy rangebull 03 divide 30 MeV
Overall dimensions weightbull Oslash 90times230 mm 09 kg
BETA BDZB-99Detector bull GM counter 30 сm2
Measurement range (for Sr-90+Y-90)bull 20 divide 104 min-1см-2
Energy rangebull 012 divide 30 MeV
Overall dimensions weightbull Oslash 88times80 mm 04 kgbull Telescopic pole length 07 m
BETA BDZB-96BDetector bull GM counter 80 сm2
Measurement range (for Sr-90+Y-90)bull 3 divide 104 min-1сm-2
Energy rangebull 012 divide 30 MeV
Overall dimensions weightbull 150times200times110 mm 15 kg
BETA BDZB-96Sbull Detector GM counter 15 сm2
Measurement range (for Sr-90+Y-90)bull 10 divide 3104 min-1cm-2
Energy rangebull 012 divide 30 MeV
Overall dimensions weightbull Oslash 65times65 mm 03 kgbull Telescopic pole length 07 m
BDZB-96
BDZB-99
BDZB-96B
BDZB-96S
EXTERNAL PROBES BETA
GAMMA BDKS-96BDetector bull Tissue-equivalent scintillator Oslash 45times20 mm
Measurement rangebull Dose rate H(10) 01 μSvh divide 1 Svhbull Dose H(10) 01 μSv divide 10 Sv
Energy rangebull 0015 divide 10 MeV
Overall dimensions weightbull Oslash 60times250 mm 085 kg
GAMMA AND BETA BDKS-96SDetector bull Double GM counters
Measurement rangebull Gamma dose rate H(10) 01 μSvh divide 1 mSvhbull Gamma dose H(10) 01 μSv divide 10 Svbull Beta 10 divide 3104 min-1cm-2
Energy rangebull Gamma 005 divide 3 MeVbull Beta 012 divide 3 MeV
Overall dimensions weightbull Oslash 80times80 mm 035 kgbull Telescopic pole length 07 m
GAMMA BDMG-96Detector bull GM counters
Measurement rangebull Dose rate H(10) 01 μSvh divide 10 Svhbull Dose H(10) 01 μSv divide 10 Sv
Energy range bull 005 divide 3 MeV
Overall dimensions weightbull 40times250 mm 05 kgbull Telescopic pole length 07 m 4 m (by request)
EXTERNAL PROBES GAMMA
BDKS-96B
BDMG-96
BDKS-96S
SPC ldquoDozardquoRadiation monitoring equipment
58 59
GAMMA-SEARCH BDVG-96Detector bull Scintillator NaI(Tl) Oslash 63times63 mm
Measurement rangebull Flux density measurement range 4 divide 2000 s-1cm-2
bull Dose rate H(10) for Cs-137 01 divide 30 μSvhbull Sensitivity for Cs-137 3000 (pulsess-1)( μSvh-1)
Overall dimensions weightbull Oslash 88times400 mm 20 kgbull Modular pole length 16 m
GAMMA-SEARCH BDPG-96Detector bull Scintillator NaI(Tl) Oslash 25times40 mm
Measurement rangebull Flux density measurement range 10 divide 8000 s-1cm-2
bull Dose rate H(10) for Cs-137 01 divide 100 μSvhbull Sensitivity for Cs-137 500 (pulsess-1)( μSvh-1)
Overall dimensions weightbull 50times190times480 mm 10 kgbull Telescopic pole length 07 m
GAMMA-SEARCH BDPG-96MDetector bull Scintillator NaI(Tl) Oslash 18times30 mm
Measurement rangebull Flux density measurement range 10 divide 24000 s-1cm-2
bull Dose rate H(10) for Cs-137 01 divide 300 μSvhbull Sensitivity for Cs-137 200 (pulsess-1)( μSvh-1)
Overall dimensions weightbull Oslash 35times320 mm 05 kgbull Telescopic pole length 07 or 38 m
EXTERNAL PROBES GAMMA
BDVG-96
BDPG-96M
BDPG-96
EXTERNAL PROBESGAMMA BDKG-96 STAINLESS STEEL CASING FOR GEOLOGIC APPLICATIONS WELL LOGGINGDetector bull Scintillator NaI(Tl) Oslash 18times30 mm
Measurement rangebull Flux density measurement range 10 divide 105 s-1cm-2
bull Dose rate H(10) for Cs-137 5 divide 2104 μRhbull Sensitivity for Cs-137 200 (pulsess-1)( μSvh-1)
Overall dimensions weightbull Oslash 38times535 mm 36 kgbull Cable length 10 divide 1000 m
NEUTRON BDMN-96Detector bull Scintillator with ZnS(Ag)
Measurement rangebull Dose rate H(10) 01 μSvh divide 01 Svhbull Dose H(10) 01 μSv divide 10 Sv
Energy range bull 0025 eV divide 10 MeV
Overall dimensions weightbull Detector Oslash 54times200 mm 08 kgbull Moderator Oslash 245 mm 73 kg
NEUTRON-SEARCH BDKN-96Detector bull He-3 counter in polyethilene moderator
Measurement rangebull Dose rate H(10) for Pu-Be 01 μSvh divide 01 Svhbull Dose H(10) for Pu-Be 01 μSv divide 10 Sv
Energy range bull 0025 eV divide 14 MeV
Overall dimensions weightbull 295times142times100 mm 225 kg
BDKG-96M
BDMN-96
BDKN-96
SPC ldquoDozardquoRadiation monitoring equipment
60 61
bull No gas supply neededbull Clothing control detachable right hand detector bull Alpha detector optional connection bull Numeric and color (red green) indication of
control resultsbull LED sensor of hand-foot positioning for start of
measurementbull Automatic compensation of gamma background
and contamination of detectorbull Audible alarm signals of the excess of preset
thresholdsbull Measurement value indication min-1cm-2 or
Bqсm2
Reference standards Nuclear IEC 61098
RZB-05D HAND-FOOT-CLOTHING MONITOR
Physical characteristicsDetectors bull Gamma beta - GM countersbull Alpha - scintillatior ZnS(Ag)
Detecting nuclidesbull Alpha Pu-239 U-234 U-238bull Beta Sr-90+Y-90 F-18 Cs-137 Co-60 Tс-99 O-15
N-13 Sr-89 C-11 I-131 Na-22 Ru-106+Rh-106 Tl-204
bull Gamma Tc-99m I-123
Efficiencybull Alpha
Pu-239 40 U-234 25U-238 15
bull Beta Sr-90 +Y-90 40
Measurement range bull Alpha 1 divide 103 min-1cm-2 bull Beta 10 divide 103 min-1cm-2
bull Gamma 5103 divide 5106 min-1cm-2
Energy range bull Alpha 30 divide 80 MeV bull Beta 008 divide 35 MeV bull Gamma 005 divide 30 MeV
Operation temperature range bull Minus 10 divide +50 ordmС
Electrical characteristicsbull Power supply 220 V 50 Hz
Mechanical characteristicsOverall dimensions weight bull 740times750times1180 mm 45 kg
Versionsbull Withwithout alpha detectorbull Indication (min-1cm-2 ) or (Bqсm2)bull Detectors overall dimensions smbull Hand 178 х 235bull Foot 185 х 436
Whole body contamination monitor RZBA-04-04Mbull No gas supply neededbull Compensation for background gamma radiation
and contamination of detector unitsbull Individual threshold setting for each measure-
ment channelbull Visible and audible alarms ldquoCONTAMINATIONrdquo and
ldquoCLEANrdquo bull Indication of contaminated body parts on the
panel with image of the bodybull Optional remote alpha-detector
Physical characteristicsDetectors bull Beta - GM counters scintillatorsbull Alpha - scintillatior ZnS(Ag)
Measurement range bull Beta 5 divide 15000 min-1cm-2
bull Alpha 01 divide 10000 min-1cm-2
Energy range bull Beta 015 divide 25 MeV bull Alpha 40 divide 56 MeV
Operation temperature range bull +5 divide +50 ordmС
Electrical characteristicsPower supply bull 220 V 50 Hz
Interfaces bull RS-232bull RS-485
Mechanical characteristicsOverall dimensions weight bull 2650times940times930 mm 310 kg
Versionsbull Withwithout alpha detectorbull Indication (min-1cm-2 ) or (Bqсm2)
Reference standards Nuclear IEC 61098
RZBA-04-04MWHOLE BODY CONTAMINATION MONITOR
SPC ldquoDozardquoRadiation monitoring equipment
62 63
RZA-05DALPHA HAND-MONITOR
bull No gas supply needed bull Numeric and color (red green) indication of
control resultsbull LED sensor of hand- positioning for start of
measurementbull Audible alarm signals of the excess of preset
thresholdsbull Measurement value indication min-1cm-2 or
Bqсm2
Physical characteristicsDetectors alpha - scintillatior ZnS(Ag)
Efficiencybull Pu-239 20 bull U-234 14bull U-238 8
Measurement range bull 05 divide 105 min-1cm-2
Energy range bull 41 divide 90 MeV
Operation temperature range bull minus 10 divide +50 ordmС
Electrical characteristicsPower supply bull 220 V 50 Hz
Mechanical characteristicsOverall dimensions weight no more bull 740times1400times1450 mm 70 kg
Reference standards Nuclear IEC 61098
bull Simultaneous measurement of alphabeta activi-ties in the sample
bull Active shielding anti-coincidence background subtraction using GM counters
bull Lead shielding 30 mm
UMF-2000 LOW LEVEL ALPHA- BETA- COUNTER
Physical characteristicsDetectors bull Silicon specrometric detector 500 or 1000 mm2
Measurement range bull Alpha 001 divide 1000 Bq bull Beta 01 divide 3000 Bq
Energy range bull Alpha 35 divide 80 MeV bull Beta 005 divide 35 MeV
Electrical characteristicsPower supply bull 220 V 50 Hz
Interfaces bull RS-232bull USB
Mechanical characteristicsOverall dimensions weight bull 337times286times190 mm 22 kg
Versionsbull Detector area 500 mm2
bull Detector area 1000 mm2
UMF-2000 Detector area 1000 mm2
UMF-2000 Detector area 500 mm2
SpectraDec software for alpha-spectrometric measurements
SPC ldquoDozardquoRadiation monitoring equipment
64 65
DRK DOSE AREA PRODUCT METER
DRK-1bull Diagnostic reference level (DRL) of patients
determinationbull Suitable for all basic types of x-ray machines
Physical characteristicsDetector bull Plane-parallel ionization chamber
Measurement range bull 1 divide 104 cGycm2
Electrical characteristicsPower supply bull 220 V 50 Hz
DRK-1M-CTbull Measuring of dose length product
Physical characteristicsDetector bull Pencil Ionization Chamber
Measurement rangebull 05 divide 109 microGym
DRK-1Mbull Measuring of air kerma on sectional area of the
X-ray beam productbull Measuring of air kerma rate on area productbull Measuring of air kerma ratebull Measuring of air kerma
Physical characteristicsDetector bull Plane-parallel ionization chamber
Measurement rangebull 01 divide 109 microGym2
bull 06 divide 6104 microGym2cbull 30 divide 9105 microGycbull 30 divide 9991011 microGyReference standard IEC 60580 2003
bull Measurement of strontium-90 in the foodstuffs agricultural products etc
bull Measurement of gross beta activity in samplebull Self tests using built-in LED
ldquoPROGRESS-BETArdquo SCINTILLATION BETA SPECTROMETER
Physical characteristicsDetector bull Plastic scintillator Oslash70x10 mm
Sample bull Plate Oslash70 mmbull Weight up to 15 g
Energy range bull 02 divide 30 MeV
Minimum detectable activity of Sr-90 in a 10 g sample on a standard planchet Bqsamplebull In case of absence of K-40 in the sample 01 Bqbull In case the activity of K-40 till 5 Bqg 05 Bq
Electrical characteristics Interface bull USB
Mechanical characteristicsWeight bull No more 50 kg
Complete setBasic complete setbull Detector unit with plastic scintillator integrated
power supply amplifier ADC bull Lead shielding bull ldquoProgressrdquo software bull Сheck source for energetic calibration (Sr-90-Y-90) bull Planchet Oslash 70 mm (5 items) bull Sample dencification device bull Procedure manual for measurement of radio-
nuclidesrsquo activity using the scintillation beta spec-trometer ldquoProgressrdquo
Optional equipment and servicebull Personal computer and printer bull Calibrations for radionuclides not included in the
main library of radionuclides
Progress-Beta
Reference standards IEC 61562
SPC ldquoDozardquoRadiation monitoring equipment
66 67
bull Measurement of gamma activity in foodstuffs soil samples and others environmental objects
bull Identification of radionuclides in the sample bull Automatic correction for sample density bull Self-tests using built-in LED
ldquoPROGRESS-GAMMArdquoSCINTILLATION GAMMA SPECTROMETER
Physical characteristicsDetector bull NaI (Tl) Oslash63times63 mm
Validated measurement geometries bull Marinelli beakers (1 liter) Petri dishes (Oslash90 mm)
etc
Energy range bull 02 divide 30 MeV
Minimum detectable activity Bqsamplebull Cs-137 3 Bqbull Th-232 7 Bqbull Ra-226 8 Bq bull К-40 40 Bq
Electrical characteristics Interface bull USB
Mechanical characteristicsWeight bull No more 120 kg
Complete setBasic complete setbull Scintillation detector unit with NaI (Tl) detector
with integrated power supply amplifier and ADC bull Lead shielding 50 mm bull ldquoProgressrdquo software bull Сheck source for energy calibration (Cs-137 +
K-40)bull Marinelli beakers - 1 liter (5 items) bull Petri dishes Oslash 90 mm (5 items) bull Procedure manual for measurement of activity
of radionuclides using the scintillation gamma spectrometer ldquoProgressrdquo
Optional equipment and servicebull Kit for radon measurements including calibration
of ldquoIC-63rdquo geometry for counting the charcoal samples
bull Personal computer and printer bull Calibrations for user defined geometries bull Calibrations for radionuclides not included in the
main library of radionuclides
Progress-Gamma
Reference standards IEC 61563
ldquoPROGRESS-G(P)rdquoPORTABLE SCINTILLATION GAMMA SPECTROMETERbull Field measurements of gamma activity in environ-
mental objects without sampling (4π geometry)bull Laboratory measurement of gamma activity in
foodstuffs soil samples and others environmental objects
bull Identification of radionuclides in the sample bull Automatic correction for sample densitybull Tests using built-in LED
Physical charachteristicsDetector bull NaI (Tl) Oslash45times50 mmbull Lead shielding 20 mm
Validated measurement geometries bull Marinelli beakers (05 liter) Petri dishes (Oslash90 mm)
etc
Energy range bull 02 divide 30 MeV
Minimum detectable activity in 05-litre Marinelli beaker bull Cs-13710 Bqkgbull К-40100 Bqkgbull Ra-22618 Bqkg bull Th-23216 Bqkg
Minimum detectable activity in 30 min (4π geometry) bull Cs-137 2 Bqkgbull К-40 30 Bqkgbull Ra-226 4 Bqkg bull Th-232 3 Bqkg
Electrical characteristicsPower supply bull Rechargeable batterybull 220 V 50 Hz
Interface bull USB RS-232
Weight bull No more than 60 kg
Complete setBasic complete setbull Scinttillation detector unit with NaI(Tl) bull ldquoProgressrdquo softwarebull Сontrol unit ldquoSputnikrdquo for aquisition and analisys
of spectra with built-in memory for spectral databull Casebull Lead shielding (2 cm) for laboratory usebull 05-litre Marinelli beakers ndash 5 itemsbull Na-22 check sourcebull Power adapter BPS-01bull Operation manualbull Procedure manual for measurement of activity
of radionuclides using the scintillation gamma spectrometer ldquoProgressrdquo
Optional equipment and servicebull Kit for radon measurements with charcoalbull Built-in dose rate meterbull Additional memory (RAM) for storage of 64
spectrabull Additional power adapterbull Notebook and printer
Progress-Gamma
Reference standards IEC 61563
SPC ldquoDozardquoRadiation monitoring equipment
68 69
Physical characteristicsDetectorbull Scintillation detector ZnS (Oslash 60 mm)
Samplebull Thin sample - diameter up to 70 mm bull Preparation technique - electro-depositionbull Thick sample - diameter 70 mm weight
200300 mg bull Preparation technique - application of powders
(prepared by radiochemical concentration by water evaporation or by pounding of mineral samples) onto a planchet with the help of spirit
Energy rangebull 15 divide 8 MeV
Minimum detectable activitybull Thin samples no more than 910-3 Bqsamplebull Thick samples no more than 180 Bqkg
Mechanical characteristicsOverall dimensions weightbull 195times120times210 mm 34 kg
Complete setBasic complete setbull Alpha radiometer ldquoProgress-ARrdquobull Check source (uranium isotopes)
Set of accessoriesbull Procedure manual for measurements of radi-
oactivity using scintillation alpha radiometer ldquoProgress-ARrdquo
bull ldquoProgressrdquo software
ldquoProgress-ARrdquo
bull Measurement of gross activity of alpha emitting radionuclides in thin samples
bull Measurement of gross activity of alpha emitting radionuclides in thick samples
bull Measurement of activity deposited on aerosol filters
ldquoPROGRESS-ARrdquoALPHA RADIOMETER
Several fixed positions of the detector enable to perform measurements in various geometries and to estimate the content ofbull Cs-137 in the whole bodybull I-131 in thyroidbull Co-60 Cs-137 Mn-54 Cr-51 in lungsbull Database for storage of measurement data and
resultsbull Uncertainty calculations based on measurement
databull Self tests using built-in LED
ldquoPROGRESSrdquo WHOLE BODY COUNTER
Physical characteristicsDetectorbull scintillation detector NaI (Tl) Oslash63times63 mm
Energy rangebull 02 divide 28 MeV
Minimum detectable activitybull By Cs-137 in the whole body - 1200 Bqbull By I-131 in thyroid - 100 Bqbull By Co-60 Cs-137 Mn-54 Cr-51 in lungs - 200 Bq
Mechanical characteristicsWeight bull No more than 120 kg
Complete setBasic complete setbull Collimator with rotator and holderbull Detector with incorporated ADCbull Patient chair and table for collimatorbull Check source Na-22bull Procedure manual for lifetime measurement of
gamma-emitting radionuclidesrsquo activity in human body using the gamma-spectrometer of human radiation ldquoProgressrdquo
bull laquoProgressraquo software
Optional equipment and servicebull Program of internal radiation committed internal
radiation effective dose calculation by the stand-ard model
bull Background phantombull Personal computer and printer
Collimator with rotator and holder
SPC ldquoDozardquoRadiation monitoring equipment
70 71
bull Categorization of wastes for the purpose of fur-ther processing including wastes with unknown radionuclide composition
bull Measurements during the incoming waste inspec-tion (accepting for storage disposal)
bull Certification of unconditioned and conditioned wastes in closed containers without opening them (at nuclear plants or at facilities providing collection storage transportation conditioning processing temporal storage and final disposal of radioactive waste)
bull Activity measurement of extended objects in situ without opening the equipment
bull Activity measurement of extended objects after opening (for example assessment of tubes used for oil transportation)
MKG-01D ldquoSADOVNIKrdquoSPECTROMETRY SYSTEM
Physical charachteristicsDetectorbull Detector unit GEM (GMX) with HPGe detector and
multi-positioning cryostat CFG-PMOD4-7 with 7 litre Dewar
bull Dose rate probe BDMG-200
Energy range bull With GEM detector 004 divide 30 MeVbull With GMX detector 0005 divide 15 MeVbull Dose rate probe BDMG-200 ndash 005 divide 30 MeV
Measurement rangebull 110-7 divide 10 Svhbull Relative efficiency of detection (in photopeak) at
13325 MeV (Co-60) 10 divide 150
Electrical characteristicsPower supplybull 220 V 50 Hz
Interfacebull USB
Complete setBasic complete setbull Spectrometric detector unit GEM (GMX) with
HPGe detector and multi-positioning cryostat with 7 litre Dewar
bull Portable digital multichannel analyzer DigiDARTbull Dose rate probe BDMG-200bull Autonomous power supply unit with built-in
batterybull Industrial computer keyboardbull Laser range-finderbull Thermographic printerbull Web-camerabull Device equipped with stepper motor for position-
ing of the spectrometric detectorbull Calibration device with reference sources
(Am-241 Co-60 Ba-133 Eu-152) for energy calibration
bull Removable collimators with end capbull Measurement proceduresbull ldquoClasterrdquo software
bull Measurement of gross alpha activity of alpha-emitting radionuclides
bull Measurement of alpha-emitting radionuclides activity in thin-layer samples meeting alpha-spectrometry requirements
Physical characteristicsDetectorbull Silicon ion-implanted 450 mm2
bull Easy to decontaminate thin windowbull dead layer less than 015 μmbull Background count rate in the range 3 divide 9 MeVbull No more than 09 h-1cm-2 for 450 mm2 detector
Energy rangebull 2 divide 9 MeVbull Lower limit of measurement range (minimum
detectable activity) 01 Bqbull Background count rate no more than 100 counts
in 24 hours
Electrical characteristics Power supplybull 220 V 50 Hz
Interfacebull USB
Complete setBasic complete setbull Detector unit with vacuum measuring chamber
and vacuum control systembull Low noise vacuum pump (type 2FY-05B or
equivalent)bull Check sourcebull ldquoProgressrdquo softwarebull Vacuum tube
MKS-01A ldquoMULTIRAD-ASrdquoALPHA SPECTROMETER
SPC ldquoDozardquoRadiation monitoring equipment
72 73
UCRV-2AIRFLOW MONITOR
bull Monitor of the air flow through filter of centralized multichannel sampling system
bull Radiation monitoring system (RMS) integration for internal exposures determination
bull Volume and flow rate measurements of the air that have passed through a analytical filter
bull Bar-code for filter identificationbull Operation as either standalone unit or as a part of
the RMS
Physical characteristicsMeasurement range of air volume bull 001 divide 9999 m3
Operation temperature range bull minus 20 divide +50 ordmС
Electrical characteristicsPower supply bull 220 V 50 Hz
Interface bull RS-485
PVP-06PORTABLE AIR SAMPLER
Air Sampler PVP-06 is indispensable for monitoring the radiation situation where the concentration of radioactive aerosols in the air does not require a sta-tionary sampling equipment Sampling head PVP-06 provides easy change of filters and cartridges
Purposebull To monitor the concentration of radioactive aero-
sols in the air sites
Controlled aerosolsbull Alpha- and beta-active aerosolsbull Daughter products of decay of radon and thoronbull Iodine isotopes
Physical characteristicsTypes of filtersbull Aerosol AFA-RSP-20bull Iodine AFA SI-20
Flow rate bull 33∙10-4 ndash 233∙10-4 m3s (20 divide 140 l min)
Electrical characteristicsPower supply bull 220 V50 Hzbull The vehicle power supply 108 divide 145 Vbull Internal battery
Minimal working time on internal battery to recharge bull 8 hours
Power consumption (at a flow rate of 100 lmin) bull 40 VA
Environment characteristicsOperating temperature bull minus 10 divide +40 deg C
Maximum humidity bull 90
Pressure bull 860 to 1060 hPA
Noise generated by the pump bull lt 55 dBA at 1 m
Mechanical characteristicsDimensions weight bull 241 times 108 times 160 mm 28 kg
Case material bull Plastic
Complete setbull Air sampler PVP-06bull AC power adapterbull Filters AFA-RSP-20 - 100 pcsbull Packaging for filters - 40 pcsbull Casebull Operation manualbull Calibration certificate
Optional equimpient bull Kit for sampling sorption columns of activated
carbon Ř head of sorption columns with protective
covers Ř activated charcoal SKT-3 - 1 pkg (02 L) Ř charocoal samples SC-13 - 8 pcs
bull Car charger bull Tipod bull Shoulder strapbull Calibration stand bull Filters AFA SI-20 - 100 pcs
Consumablesbull Aerosol filters AFA RSP-20bull Iodine filters AFA SI-20
SPC ldquoDozardquoRadiation monitoring equipment
74 75
Calibration of gamma dose and dose rate meters
Calibration ofbull Ambient equivalent dose H(10) meters (Sv Svh)bull Personal equivalent dose Hp(10) meters (Sv Svh)bull Exposure dose X meters (R Rh)bull Two sources in irradiator bull Select source and collimator opening using
tumbler
UPG-P DESKTOP GAMMA BEAM IRRADIATOR
Physical characteristicsRange of reproduced dose rate bull 05 μSvh divide 10 mSvh (50 μRh divide 100 mRh)
Sources activities bull 6times106 6times108 Bq (02 20 mCi) Cs-137
Overall dimensions bull 1250times400times300 mm
Irradiator weight bull Not more than 37 kg
Calibration bench weight bull Not more than 15 kg
Reference standards IEC 60846 IEC 61526
Physical characteristicsDetectorbull Silicon
Measurement range EEC measurement bull Measurement range of radon EEC
10 divide 10bull106 Bqbullm-3
bull Measurement range of thoron EEC 05 divide 10bull104 Bqbullm-3
bull Air flow through the filter 100plusmn05 lmin
Concentration measurementbull Measurement range of radon-222 concentration
in air 10 divide 20bull106 cpsbull Measurement range of 216Po(ThA)
1bull10-3 divide 1bull102 cpsbull Air sampler flow rate
10plusmn02 lminbull Measurement range of radon-222 concentration
in water samples 6 divide 800 Bqbullkg-1
bull Measurement range of radon-222 flux from soil surface 20 divide 103 mBqsbullm2
bull Measurement range of radon-222 concentration with preliminary sampling of air using air sam-plers 20 divide 107 Bqbullm-3
bull Measurement range of radon-222 concentration in samples of soil air 103 divide 106 Bqbullm-3
Operation temperature range bull 1 divide 35 ordmC
Electrical characteristicsPower supply bull 80 VA
Mechanical characteristicsOverall dimensions weight bull 220times200times165 mm 36 kg
ldquoALPHARAD PLUSrdquoRADON THORON amp THEIR PROGENY MONITORbull Measurement of radon and thoron concentration
and effective equivalent concentration (EEC)bull In the airbull In the indoor air of residential public and industri-
al buildings and structuresbull Measurement of radon in drinking water sourcesbull Measurements of radon flux from the soil surface
at land plots allocated for construction of houses public buildings and industrial facilities
bull Measurements of radon concentration in soil air
Reference standards IEC 61577
SPC ldquoDozardquoRadiation monitoring equipment
76 77
UKPN-2M-D NEUTRON BEAM IRRADIATOR
Reference standards IEC 61005 61322
Calibration of neutron dose and dose rate meters
Calibration ofbull Ambient equivalent dose H(10) meters (Sv Svh)bull Personal equivalent dose Hp(10) meters (Sv Svh)bull Flux density of neutrons (cm-2∙s-1)bull Transfer container for temporary storage of
sources bull Red light signal of source working position
Physical carachteristicsRange of reproduced dose ratebull 20 divide 800 μSvh
Range of reproduced flux densitiesbull 10 divide 400 cm-2∙s-1
Type of a source in use bull Pu-Be
Activity of a source in usebull 24х1011 Bq (with density of 107 s-1)
Overall dimensions weight no morebull 3000x750x2000 mm 300 kg
Required room dimensionsbull not less than 7x3x3 m
Electrical characteristicsPower supply bull 220 V 50 Hz
Calibration of gamma dose and dose rate meters
Calibration ofbull Ambient equivalent dose H(10) meters (Sv Svh)bull Personal equivalent dose Hp(10) meters (Sv Svh)bull Exposure dose X meters (R Rh)bull Four sources in irradiator bull Select source and move to working position
return to storage position using special rodbull Transfer container for temporary storage of
sources bull Red light signal of source working position
UPGD-2M-DGAMMA BEAM IRRADIATOR
Physical characteristicsRange of reproduced dose rate bull 05 μSvh divide 50 mSvh (50 μRh divide 5 Rh)
Maximum activity of source bull 2times1011 Bq (50 Ci) Cs-137
Overall dimensionsbull Irradiator 800times500times500 mmbull Guide rails length 30 mbull Height 16 mbull Weight not more than 700 kgbull Required room dimensions not less than 7x3x3 m
Electrical characteristicsPower supply bull 220 V 50 Hz
UPGD-2M-D
Reference standards IEC 60846 IEC 61526 IEC 61066
SPC ldquoDozardquo
78 79
Contents
MEASURING UNITS
DBG-S11D wide range gamma area monitor 40
UDKS-100 gamma and X-ray area monitor 41
UDMN-100 neutron area monitor 41
ALARM UNITS
BAS-2 ldquoMICROrdquo external visual alarm 42
BZS-2 ldquoMicrordquo external audible alarm 42
Illuminated warning signs 43
ldquoImpulsrdquo external display unit 43
UIM-3D area monitor count rate meter 44
DKG-05D personal gamma dosimeter 46
DVS-02D gamma-neutron personal electronic dosimeter 47
DVGI-8D new pen-type personal ionization chamber dosimeters 48
DKG-02U ldquoARBITERrdquo wide range gamma-dosimeter 49
DKG-07D ldquoDROZDrdquo gamma-dosimeter 50
MKS-15D ldquoSNEGIRrdquo multi ndash purpose radiation survey meter 51
SRPS-05D gamma monitor 52
DOZA-TLD multipurpose TLD system 53
DKS-96 universal radiation survey meter 54
EXTERNAL PROBES ALPHA
Alpha BDZA-96 55
Alpha BDZA-96B 55
Alpha BDZA-96M 55
Alpha BDZA-96S 55
Alpha BDZA-96T 55
EXTERNAL PROBES BETA
Beta BDZB-96 56
Beta BDZB-99 56
Beta BDZB-96B 56
Beta BDZB-96S 56
EXTERNAL PROBES GAMMA
Gamma BDKS-96B 57
Gamma and beta BDKS-96S 57
Gamma BDMG-96 57
EXTERNAL PROBES GAMMA
Gamma-search BDVG-96 58
Gamma-search BDPG-96 58
ContentsRadiation monitoring systemldquoPELIKANrdquo Radiation monitoring system (RMS) 6
BDMG-101 high range gamma area monitor 10
DBG-S11D wide range gamma area monitor 11
BDRG-52 high range gamma area monitor for accident and post-accident conditions 12
UDGP-01 Liquid technological environments monitor 13
UDMN-100 neutron area monitor 14
UDKG-100 Wel Liquid gamma monitor 14
BOP-1M data processing and transmission unit 15
UDA-1AB particulate monitor 16
UDG-1B noble gas monitor 17
UDG-03D noble gas monitor 18
UDI-1B iodine monitor 19
UDGB-01 noble gasesH-3C-14 monitor 20
UDGP-01 steam generator leakage monitor 21
UPPVM air flow parameters monitor 22
ldquoIMPULSrdquo external display unit 23
BI-2 remote display amp alarm unit 24
BASBAS-1s external alarm 25
SKGAV stack monitor 26
RMS software 28
RMS workstation ndash operator console 29
Configurator software 29
RM RACK radiation monitoring rack 30
SRKS-01D criticality accident alarm system 32
ldquoATLANT-Mrdquo environmental radiation monitoring system 34
ldquoBREEZErdquo high-volume air sampler 35
ldquoGAMMA-SENSORrdquo gamma-survey system 36
Radiation monitoring equipmentAREA MONITOR ldquoFREGATrdquo 38
BPI-1D local display unit 39
80
Gamma-search BDPG-96M 58
Gamma BDKG-96 stainless steel casing for geologic applications well logging 59
EXTERNAL PROBES NEUTRON
Neutron BDMN-96 59
Neutron-search BDKN-96 59
RZB-05D Hand-foot-clothing monitor 60
RZBA-04-04M whole body contamination monitor 61
RZA-05D alpha hand-monitor 62
UMF-2000 low level alpha- beta- counter 63
DRK dose area product meter 64
ldquoPROGRESS-BETArdquo scintillation beta spectrometer 65
ldquoPROGRESS-GAMMArdquo scintillation gamma spectrometer 66
ldquoPROGRESS-G(P)rdquo portable scintillation gamma spectrometer 67
ldquoPROGRESS-ARrdquo alpha radiometer 68
ldquoPROGRESSrdquo whole body counter 69
MKG-01D ldquoSADOVNIKrdquo spectrometry system 70
MKS-01A ldquoMULTIRAD-ASrdquo alpha spectrometer 71
UCRV-2 airflow monitor 72
PVP-06 portable air sampler 73
ldquoALPHARAD PLUSrdquo radon thoron amp their progeny monitor 74
UPG-P desktop gamma beam irradiator 75
UPGD-2M-D gamma beam irradiator 76
UKPN-2M-D neutron beam irradiator 77
SPC ldquoDozardquoRadiation monitoring equipment
38 39
AREA MONITOR ldquoFREGATrdquoArea Monitor ldquoFregatrdquo is designed for building rela-tively simple and inexpensive radiation monitoring systems at such facilities as radionuclide sources storage areas isotope products warehouses nuclear medicine departments PET centers calibration laboratories where sources of ionizing radiation are used etc
Small scale automated radiation monitoring systems built with ldquoFregatrdquo components featuring audible and visual alarms are matched suitable to meet the regulatory radiation safety requirements
Area monitor ldquoFregatrdquo requires virtually no adjust-ment it is simple and convenient for installation and operation
BPI-1D LOCAL DISPLAY UNIT
Display of monitored parameters values received from external measuring devices
Purposebull Processing and display of values of monitored
parameters on information panel bull Comparison of values of monitored parameters
with thresholdsbull Transfer of monitored parametersrsquo values to
networkbull Generation of alarm in case of exceeding of preset
thresholds including external alarm devices
FeaturesTesting the unit and connected devicesbull Visually on the panelbull Using adjustment software when connected to
PC via USB
Automatic self-testing
The panel displays the following informationbull Diagnostic information about the status of con-
nected devicesbull Current date and timebull Values of measured parametersbull Position of measured values with respect to the
thresholds in the form of scales with green yellow and red zones
bull Time history (trend) for each measured value
Physical characteristicsTemperature range bull minus 10 divide + 50 ordmC
Maximum number of connected devicesbull measuring devices 15bull external audible and visual alarm 15
Display diagonal bull 152 cm (6)
Electrical characteristicsbull Interfaces RS-485bull Power supply 220 V 50 Hz 12 divide 24 V
Mechanical characteristicsbull Protection index IP54bull Paint decontaminable
Overall dimensions weightbull 296x248x118 mm 5 kg
DBG-S11D wide range gamma area monitor
UDMN-100 neutron area monitor
Ethernet RS-485
UDKS-100 gamma and X-ray area monitor
BPI-1D Local display unit
BAS-2 ldquoMicrordquo external visual alarm
BZS-2 ldquoMicrordquo external audible alarm
ldquoImpulsrdquo external display unit
Service workstation
Illuminated warning signs
SPC ldquoDozardquoRadiation monitoring equipment
4140
Continuous automatic monitoring of the gamma- X-ray ambient dose equivalent rate
Physical characteristicsbull Detector tissue-equivalent plastic scintillator
Oslash 45times20 mm
Measurement range bull Dose rate measurement range 01 μSvh divide 1 Svh bull Energy range 0015 divide 10 MeV
Mechanical characteristicsbull Protection index IP65bull Paint decontaminable
Overall dimensions weightbull Oslash72times265 mm 15 kg
UDKS-100 GAMMA AND X-RAY AREA MONITOR
UDMN-100 NEUTRON AREA MONITOR
Physical characteristicsbull detector ndash scintillator ZnS(Ag) Li-6
Measurement range bull 01 μSvh divide 01 Svh
Energy range bull 0025 eV divide 100 MeV
Temperature range bull minus 45 divide +50 ordmC
Electrical characteristicsbull Interfaces RS-485
Mechanical characteristicsbull Protection index IP 65bull Paint decontaminable
Overall dimensions weight bull 428times258times347 mm 115 kg
Continuous automatic monitoring of the neutron-radiations ambient dose equivalent ratebull Spherical polyethylene moderator Oslash 239 mm
MEASURING UNITS
DBG-S11D WIDE RANGE GAMMA AREA MONITOR
Continuous automatic monitoring of the gamma- ambient dose equivalent rate
Physical characteristicsbull Detector ndash GM counters
Measurement rangebull DBG-S11D 01 μSvh divide 10 mSvhbull DBG-S11D-01 01 μSvh divide 10 Svhbull DBG-S11D-02 01 μSvh divide 100 Svh
Energy rangebull 005 divide 30 MeV
Temperature range bull minus 40 divide +50 ordmC
Electrical characteristicsbull Interfaces RS-485 USB
Mechanical characteristicsbull Protection index IP 68bull Paint decontaminable
Overall dimensions weightbull DBG-S11D Oslash 68times141 mm 065 kg bull DBG-S11D-01 Oslash 68times179 mm 07 kgbull DBG-S11D-02 Oslash 68times179 mm 07 kg
Versionsbull DBG-S11Dbull DBG-S11D-01bull DBG-S11D-02
Reference standards Nuclear IEC 60846 IEC 60532 EMC IEC 61010 IEC 61000-6-2 Seismic IEC 60980
SPC ldquoDozardquoRadiation monitoring equipment
4342
ALARM UNITS
Generation visual signals of the excess of preset thresholds
Physical characteristicsLength of communication cablebull up to 1200 mbull Alarm Visual alarm green yellow red
Electrical characteristicsbull Power supply +12 V
Mechanical characteristicsbull Protection index IP 23
Overall dimensions weight 160times84times41 mm 02 kg
BAS-2 ldquoMICROrdquo EXTERNAL VISUAL ALARM
Generation audible signals of the excess of preset thresholds
Physical characteristicsLength of communication cablebull up to 1200 mbull Audible alarm 80 divide 100 dB at a distance of 1 m
Electrical characteristicsbull Power supply +12 V
Mechanical characteristicsbull Protection index IP 23
Overall dimensions weight 160times84times41 mm 02 kg
BZS-2 ldquoMICROrdquo EXTERNAL AUDIBLE ALARM
Physical characteristicsLength of communication cablebull up to 1200 m
Electrical characteristicsbull Power supply 220 V 50 Hz
Mechanical characteristicsbull Protection index IP 23
Overall dimensions weight bull 330times110times20 mm 05 kg
Physical characteristicsLength of communication cablebull up to 1200 m
Character height bull ldquoImpuls-910-Rrdquo 100 mmbull ldquoImpuls-915-D4Srdquo 150 mmbull ldquoImpuls-927-D4Srdquo 270 mm
Operating temperature rangebull ldquoImpuls-910-Rrdquo 0 divide +50 degCbull ldquoImpuls-915-D4Srdquo ldquo-727-D4Srdquo minus 40 divide +50 degC
Electrical characteristicsbull Power supply 220 V 50 Hz
Mechanical characteristicsProtection index bull ldquoImpuls-910-R IP 44bull ldquoImpuls-915-D4Srdquo ldquo-727-D4Srdquo IP 65
Overall dimensions weight bull ldquoImpuls-910-Rrdquo 400times160times60 mm 3 kgbull ldquoImpuls-915-D4Srdquo 815times250times80 mm 5 kgbull ldquoImpuls-927-D4Srdquo 1250times330times80 mm 5 kg
ILLUMINATED WARNING SIGNS
ldquoIMPULSrdquo EXTERNAL DISPLAY UNIT
SPC ldquoDozardquoRadiation monitoring equipment
4544
Individual threshold setting for each measurement channel
Continuous area and process monitoring
Collect amp display data from two measurement chan-nels (units with RS-485 or analog pulses)
Audible and visual alarms on exceeding preset thresholds or status of connected devices
Individual threshold setting for each measurement channel
Switching on the external alarm or executive devices when any threshold is exceeded
The wide panel displays the following information bull Values of measured parameters as min-1∙cm-2
s-1∙cm-2 μSvhbull Diagnostic information about the status of con-
nected devicesbull Current date and timebull Position of measured values with respect to the
thresholds in the form of scales with green yellow and red zones
bull Time history (trend) for each measured value
Physical characteristics Measurement range bull Count rate up to 107 CPM (170 kHz)
Operating temperature range bull minus 20 divide +50 ordmC
Electrical characteristics bull Power supply 220 V bull Interfaces USB
Mechanical characteristics bull Protection index IP 65 bull Overall dimensions weight 222times164times73 mm
40 kg
UIM-3D AREA MONITOR COUNT RATE METER
Measurement of alpha radiation flux density
Detector unit BDZA-100 (70 cm2) Measurement range 01 divide 104 min-1∙cm-2
Detector unit BDZA-100B (300 cm2) Measurement range 01 divide 2103 min-1∙cm-2
Measurement of beta radiation flux density
Detector unit BDZB-100 (28 cm2) Measurement range 10 divide 105 min-1∙cm-2
Detector unit BDZB-100L (30 cm2) Measurement range 10 divide 104 min-1∙cm-2
Detector unit BDZB-11D (84 cm2) Measurement range 5 divide 15∙104 min-1∙m-2
OPTIONAL PROBESMeasurement of gamma radiation flux density
Detector units BDEG-03 Measurement range 4 divide 2000 s-1∙cm-2
Detector unit UDKG-100 for operation in the rocks ore liquid media and sludge Measurement range 40 divide 8000 s-1∙cm-2
Measurement of the ambient dose equivalent rate
Detector unit DBG-S11D Measurement range 01 μSvh divide 100 Svh
Measurement of neutron radiation ambient dose equivalent rate
Detector unit BDMN-100 Measurement range 01 μSvh divide 01 Svh
SPC ldquoDozardquoRadiation monitoring equipment
46 47Reference standards Nuclear IEC 61526
Measurement of gamma-radiation personal dose equivalent Hp(10)bull Stand-alone dosimeter or composed of dosimetric
system onebull Audible and visual alarmbull Large memory dose accumulation historiesbull Exclusion of unauthorized intervention in dosim-
etry operation
DKG-05D PERSONAL GAMMA DOSIMETER
Physical characteristicsDetectors bull Silicon
Measurement range bull Dose rate 1 μSvh divide 10 Svhbull Dose 01 μSv divide 15 Sv
Energy range bull 005 divide 30 MeV
Electrical characteristicsbull Power supply rechargeable NiMH battery 1
alcaline battery (type AAA)
Operation timebull Till recharging not less 400 hoursbull With one set batteries not less 1000 hours
Mechanical characteristicsOverall dimensions weight bull 47times26times87 mm (with clip) 70 g
Environmental characteristicsbull IP65bull Temperature range minus 20 divide +45 ordmCbull Humidity up to 98 at 35 ordmCbull Shock vibration and drop resistant
Alarmbull Excess of alarm thresholdsbull Warnings of self-test failure and battery discharge bull Audible alarm 80 dB at 40 cmbull Visual alarm blinking LED
Relative equipmentbull One dosimeter charger ZU-1Mbull Chargestorage cassetes KZU-28KZU-56bull ldquoSmart chargingrdquo feature extends battery life timebull DKG-05D reader US-05bull DKG-05D system reader DVS-01D
Reader-PC interfacebull US-05 USB bull DVS-01D Ethernet
KZU-28
Physical characteristicsDetectors bull Silicon Li-6
Gamma measurement range bull Dose rate 1 μSvh divide 10 Svhbull Dose 01 μSv divide 15 Sv
Gamma energy range bull 005 divide 60 MeV
Neutron measurement range bull Dose rate 1 μSvh divide 2 Svhbull Dose 20 μSv divide 15 Sv
Neutron energy range bull 0025 eV divide 20 MeV
Electrical characteristicsPower supply bull Rechargeable NiMH batterybull Operatiion time till recharging not less 200 hours
Mechanical characteristicsOverall dimensions weight bull 47times26times87 mm (with clip) 70 g
Environmental characteristicsbull IP65bull Temperature range minus 20 divide +40 ordmCbull Humidity up to 75 at 30 ordmCbull Shock vibration and drop resistant
Alarmbull Excess of alarm thresholds bull Warnings of self-test failure and battery discharge bull Audible alarm 80 dB at 40 cmbull Visual alarm blinking LED
Relative equipmentbull One dosimeter charger ZU-1Mbull Chargestorage cassetes KZU-28 KZU-56bull ldquoSmart chargingrdquo feature extends battery life timebull DVS-02D reader UZS-01Sbull DVS-02D system reader DVS-01D
Reader-PC interfacebull UZS-01S USB bull DVS-01D Ethernet
UZS-01DReference standards Nuclear IEC 61526
DVS-02D GAMMA-NEUTRON PERSONAL ELECTRONIC DOSIMETER
Measurement of gamma- and neutron radiations personal dose equivalent Hp(10)bull Stand-alone dosimeter or composed of dosimetric
system onebull Audible and visual alarmbull Large memory dose accumulation historiesbull Exclusion of unauthorized intervention in dosim-
etry operationbull Both albedo thermal neutrons and intermediate
fast neutrons registrationbull Usable in the fields of Pu(Be) Po(Be) Cf and other
neutron sources as well as near nuclear reactors without neutron spectrum estimation
SPC ldquoDozardquoRadiation monitoring equipment
48 49
Dosimeters DVG-03D
DVGI-8D NEW PEN-TYPE PERSONAL IONIZATION CHAMBER DOSIMETERS
Measurement of personal dose equivalent Hp(10) of gamma and X-ray radiationbull Hp(10) of continuous and pulsed gamma and
X-ray radiation bull Electronic reader KSU-1bull Dosimeter DVG-03D with electronic ID bull Personal dose histories in the readerrsquos memorybull Readerrsquos connection with PC for database main-
tenance
Physical characteristicsDetector bull Ionization chamber
Measurement range bull 001 mSv divide 25 mSv
Energy range bull 0015 divide 25 MeV
Temperature range bull Reader KSU-1 +10 divide +50 ordmСbull Dosimeter DVG-03D minus 40 divide +50 ordmС
Electrical characteristicsPower supply bull Reader KSU-1 220 V 50 Hz built-in batteries bull Dosimeter DVG-03D four batteries CR 1025 bull Batteries life 3 yearsbull Readers interfaces RS-232USB 20
Mechanical characteristicsOverall dimensions weightbull Dosimeter DVG-03D Oslash 18times126 mm 005 kgbull Reader KSU-1 235times232times125 mm 28 kg
Reference standards Nuclear IEC 62387-1
DKG-02U ldquoARBITERrdquo WIDE RANGE GAMMA-DOSIMETER
Physical characteristicsDetectors bull GM counters
Measurement rangebull Dose-rate 01 μSvh divide 3 Svhbull Dose 1 μSv divide 100 Sv
Energy range bull 005 divide 3 MeV
Electrical characteristicsbull Power supply 2 alcaline batteries (type AA)bull Batteries life not less 200 hours
Mechanical characteristicsOverall dimensions weight bull 152times82times32 mm 03 kg
Environmental characteristicsbull Temperature range minus 20 divide +50 ordmCbull Humidity up to 90 at +25 ordmCbull Shock vibration and drop resistant
Reference standards Nuclear IEC 60846
Measurement of gamma radiation ambient equiva-lent dose H(10) and dose rate H(10)bull Audible signals (clicks) for radiation condition
estimationbull Analog scale for search modebull Audible and visual alarms of the excess of preset
dose and dose rate thresholds bull Shock-resistant water-proof easy decontamina-
tion casebull 100 measurement results memory with date and
time of measurementbull Indication of total dose accumulated during
exploitation time bull Indication of measurement result statistical
uncertainty
SPC ldquoDozardquoRadiation monitoring equipment
50 51
Physical characteristicsDetectors bull GM counter
Measurement rangebull Dose-rate 01 μSvh divide 3 mSvhbull Dose 1 μSv divide 02 Sv
Energy range bull 005 divide 3 MeV
Temperature range bull Minus 20 divide +50 ordmC
Electrical characteristicsbull Power supply 2 alcaline batteries 15 V (type AA)bull Batteries life not less 200 hours
Mechanical characteristicsOverall dimensions weight bull 122times74times29 mm 025 kg
Reference standards Nuclear IEC 60846
DKG-07D ldquoDROZDrdquoGAMMA-DOSIMETER
Measurement of gamma radiation ambient equiva-lent dose H(10) and dose rate H(10)bull Two independent measurement channels dose
and dose ratebull Audible signals (clicks) for radiation condition
estimationbull Continuous measurement with updating meas-
urement resultbull Measurement result can be obtained with any
desired statistical uncertainty (error)bull Automatic restart when radiation level sharply
changesbull Indication of statistical uncertainty (error) during
measurement process
Continuous measurement with updating measure-ment result
Automatic restart when radiation level sharply changes bull Gamma dose H(10) and dose-rate H(10) meas-
urementbull Beta and gamma contamination surveybull Indication of statistical uncertainty during the
measurementbull Continuous measurement with accuracy increas-
ing with time bull Automatic restart triggered by change of gamma
dose-ratebull Compensation of gamma count rate while meas-
uring beta radiationbull Indication of battery charge levelbull Audible signal of the excess of preset threshold
Physical characteristicsDetectors bull GM counter
Measurement range bull Dose-rate 01 microSvh divide 20 mSvhbull Dose 1 microSv divide 100 Svbull Beta flux density (for Sr-90+Y-90)
10 divide 105 cm-2 min-1
Energy range bull Gamma 005 divide 3 MeVbull Beta 01 divide 3 MeV
Temperature range bull Minus 20 divide +50 ordmC
MKS-15D ldquoSnegirrdquo backside
MKS-15D ldquoSNEGIRrdquoMULTI ndash PURPOSE RADIATION SURVEY METER
Reference standards Nuclear IEC 60846 IEC 60325
Electrical characteristicsbull Power supply 2 alcaline batteries (type AA)bull Battery life not less 400 hours
Mechanical characteristicsOverall dimensions weight bull 124times72times35 mm 035 kg
SPC ldquoDozardquoRadiation monitoring equipment
52 53
Physical characteristicsDetectorbull GM counter
Measurement range bull 01 μSvh divide 20 mSvh
Energy range bull 005 divide 30 MeV
Threshold setting range bull 03 μSvh divide 20 mSvh
Step change of the thresholdbull In the range 03 divide 10 μSvh with the step
001 μSvhbull In the range 10 divide 100 μSvh with the step
01 μSvhbull In the range 100 divide 2000 μSvh with the step
10 μSvh
Electrical characteristicsPower supply bull 220 V 50 Hz bull Relay output
Mechanical characteristicsProtection index bull IP 40
Overall dimensions weight bull 226times120times75 mm 07 kg
Alarmbull Sound alarm 80 divide 100 dBA at distance 1 mbull Visual alarm redbull Connection of the external alarm signaling unit
Reference standards Nuclear IEC 60846 IEC 60532
Continuous automatic monitoring of the ambient dose equivalent rate bull Measurement of gamma dose rate H(10)bull Audible and visual alarm signals for preset
thresholdsbull Switching on the external signaling or executive
devices
SRPS-05D GAMMA MONITOR
Measurement ofbull Gamma and X-ray personal dose equivalent
Hp(10)bull Neutron personal dose equivalent Hp(10)bull Lens dose equivalent Hp(3)bull Skin dose equivalent Hp(007)bull TLD reader day-to-day tests using built-in LEDbull No needs nitrogen for heating
Physical charachteristicsDetectors bull 7LiF Mg Ti (gamma beta)bull 6LiF Mg Ti (neutron)
Gamma and X-ray Hp(10) Measurement range bull 500 μSv divide 10 Sv
Energy range bull 0015 divide 30 MeV
Neutron Hp(10)Measurement range bull 01 mSv divide 100 mSv
Energy range bull 0025 eV divide 10 MeV
Beta and photons Hp(007) Hp(3) Measurement range bull 2 mSv divide 100 Sv
Energy range bull Beta 025 divide 35 MeVbull Photons lt15 keV
Mechanical characteristicsDosimeters overall dimensions weight bull Gamma Hp(10) DTL-2 holder - 62times26times16 mm
16 gbull DTU holder - 42times28times18 mm 8 gbull Lens Hp(3) face skin Hp(007) Oslash 32times16 mm 9 gbull Finger skin Hp(007) 90times20times2 mm 1 gbull Neutron gamma Hp(10) 48times40times20 mm 30 g
Reference standards Nuclear IEC 61066
DTL-2 DTU-2
MKD (A-type) DVNG-M
DOZA-TLD MULTIPURPOSE TLD SYSTEM
SPC ldquoDozardquoRadiation monitoring equipment
54 55
Continuous and pulsed gamma and X-ray dose H(10) and dose-rate measurementbull Alpha beta and gamma contamination surveybull Neutron dose H(10) and dose-rate measurementbull Gamma radiation flux density in boreholes and
liquid media measurement
Electrical characteristicsPower supply bull UIK-05 four C-size batteriesbull UIK-05-01 rechargeable batterybull UIK-06 rechargeable battery
Interfaces bull RS-232bull USB (via adapter)
bull Detector type automatic determination and corre-sponding measurement modes selection
bull Alarm threshold settings ndash for dose dose-rate alpha and beta contaminations
bull ldquoDetectrdquo and ldquoLocaterdquo modes for survey probes
Reference standards Nuclear IEC 60846 IEC 60325 IEC 61005 IEC 62363
Case
UIK-06 control unit165times78times48 mm 03 kg
DKS-96UNIVERSAL RADIATION SURVEY METER
UIK-05 control unit202times86times90 mm 10 kg
BDZA-96
BDZA-96B
BDZA-96M
BDZA-96S
BDZA-96T
EXTERNAL PROBES ALPHAALPHA BDZA-96Detector bull ZnS(Ag) 70 cm2
Measurement range (for Pu-239)bull 01 divide 104 min-1cm-2
Overall dimensions weightbull Oslash 130times240 mm 11 kg
ALPHA BDZA-96BDetector bull ZnS(Ag) 300 сm2
Measurement range (for Pu-239)bull 01 divide 2103 min-1cm-2
Overall dimensions weightbull Oslash 230times290 mm 40 kg
ALPHA BDZA-96MDetector bull ZnS(Ag) 10 сm2
Measurement range (for Pu-239)bull 01 divide 105 min-1cm-2
Overall dimensions weightbull Oslash 65times240 mm 09 kg
ALPHA BDZA-96SDetector bull ZnS(Ag) 30 сm2
Measurement range (for Pu-239)bull 01 divide 5104 min-1cm-2
Overall dimensions weightbull Oslash 90times240 mm 10 kg
ALPHA BDZA-96TDetector bull Silicon 5 сm2
Measurement range (for Pu-239)bull 01 divide 106 min-1cm-2
Overall dimensions weightbull Oslash 50times60 mm 015 kg
SPC ldquoDozardquoRadiation monitoring equipment
56 57
BETA BDZB-96Detector Scintillator 28 сm2
Measurement range (for Sr-90+Y-90)bull 10 divide 105 min-1cm-2
Energy rangebull 03 divide 30 MeV
Overall dimensions weightbull Oslash 90times230 mm 09 kg
BETA BDZB-99Detector bull GM counter 30 сm2
Measurement range (for Sr-90+Y-90)bull 20 divide 104 min-1см-2
Energy rangebull 012 divide 30 MeV
Overall dimensions weightbull Oslash 88times80 mm 04 kgbull Telescopic pole length 07 m
BETA BDZB-96BDetector bull GM counter 80 сm2
Measurement range (for Sr-90+Y-90)bull 3 divide 104 min-1сm-2
Energy rangebull 012 divide 30 MeV
Overall dimensions weightbull 150times200times110 mm 15 kg
BETA BDZB-96Sbull Detector GM counter 15 сm2
Measurement range (for Sr-90+Y-90)bull 10 divide 3104 min-1cm-2
Energy rangebull 012 divide 30 MeV
Overall dimensions weightbull Oslash 65times65 mm 03 kgbull Telescopic pole length 07 m
BDZB-96
BDZB-99
BDZB-96B
BDZB-96S
EXTERNAL PROBES BETA
GAMMA BDKS-96BDetector bull Tissue-equivalent scintillator Oslash 45times20 mm
Measurement rangebull Dose rate H(10) 01 μSvh divide 1 Svhbull Dose H(10) 01 μSv divide 10 Sv
Energy rangebull 0015 divide 10 MeV
Overall dimensions weightbull Oslash 60times250 mm 085 kg
GAMMA AND BETA BDKS-96SDetector bull Double GM counters
Measurement rangebull Gamma dose rate H(10) 01 μSvh divide 1 mSvhbull Gamma dose H(10) 01 μSv divide 10 Svbull Beta 10 divide 3104 min-1cm-2
Energy rangebull Gamma 005 divide 3 MeVbull Beta 012 divide 3 MeV
Overall dimensions weightbull Oslash 80times80 mm 035 kgbull Telescopic pole length 07 m
GAMMA BDMG-96Detector bull GM counters
Measurement rangebull Dose rate H(10) 01 μSvh divide 10 Svhbull Dose H(10) 01 μSv divide 10 Sv
Energy range bull 005 divide 3 MeV
Overall dimensions weightbull 40times250 mm 05 kgbull Telescopic pole length 07 m 4 m (by request)
EXTERNAL PROBES GAMMA
BDKS-96B
BDMG-96
BDKS-96S
SPC ldquoDozardquoRadiation monitoring equipment
58 59
GAMMA-SEARCH BDVG-96Detector bull Scintillator NaI(Tl) Oslash 63times63 mm
Measurement rangebull Flux density measurement range 4 divide 2000 s-1cm-2
bull Dose rate H(10) for Cs-137 01 divide 30 μSvhbull Sensitivity for Cs-137 3000 (pulsess-1)( μSvh-1)
Overall dimensions weightbull Oslash 88times400 mm 20 kgbull Modular pole length 16 m
GAMMA-SEARCH BDPG-96Detector bull Scintillator NaI(Tl) Oslash 25times40 mm
Measurement rangebull Flux density measurement range 10 divide 8000 s-1cm-2
bull Dose rate H(10) for Cs-137 01 divide 100 μSvhbull Sensitivity for Cs-137 500 (pulsess-1)( μSvh-1)
Overall dimensions weightbull 50times190times480 mm 10 kgbull Telescopic pole length 07 m
GAMMA-SEARCH BDPG-96MDetector bull Scintillator NaI(Tl) Oslash 18times30 mm
Measurement rangebull Flux density measurement range 10 divide 24000 s-1cm-2
bull Dose rate H(10) for Cs-137 01 divide 300 μSvhbull Sensitivity for Cs-137 200 (pulsess-1)( μSvh-1)
Overall dimensions weightbull Oslash 35times320 mm 05 kgbull Telescopic pole length 07 or 38 m
EXTERNAL PROBES GAMMA
BDVG-96
BDPG-96M
BDPG-96
EXTERNAL PROBESGAMMA BDKG-96 STAINLESS STEEL CASING FOR GEOLOGIC APPLICATIONS WELL LOGGINGDetector bull Scintillator NaI(Tl) Oslash 18times30 mm
Measurement rangebull Flux density measurement range 10 divide 105 s-1cm-2
bull Dose rate H(10) for Cs-137 5 divide 2104 μRhbull Sensitivity for Cs-137 200 (pulsess-1)( μSvh-1)
Overall dimensions weightbull Oslash 38times535 mm 36 kgbull Cable length 10 divide 1000 m
NEUTRON BDMN-96Detector bull Scintillator with ZnS(Ag)
Measurement rangebull Dose rate H(10) 01 μSvh divide 01 Svhbull Dose H(10) 01 μSv divide 10 Sv
Energy range bull 0025 eV divide 10 MeV
Overall dimensions weightbull Detector Oslash 54times200 mm 08 kgbull Moderator Oslash 245 mm 73 kg
NEUTRON-SEARCH BDKN-96Detector bull He-3 counter in polyethilene moderator
Measurement rangebull Dose rate H(10) for Pu-Be 01 μSvh divide 01 Svhbull Dose H(10) for Pu-Be 01 μSv divide 10 Sv
Energy range bull 0025 eV divide 14 MeV
Overall dimensions weightbull 295times142times100 mm 225 kg
BDKG-96M
BDMN-96
BDKN-96
SPC ldquoDozardquoRadiation monitoring equipment
60 61
bull No gas supply neededbull Clothing control detachable right hand detector bull Alpha detector optional connection bull Numeric and color (red green) indication of
control resultsbull LED sensor of hand-foot positioning for start of
measurementbull Automatic compensation of gamma background
and contamination of detectorbull Audible alarm signals of the excess of preset
thresholdsbull Measurement value indication min-1cm-2 or
Bqсm2
Reference standards Nuclear IEC 61098
RZB-05D HAND-FOOT-CLOTHING MONITOR
Physical characteristicsDetectors bull Gamma beta - GM countersbull Alpha - scintillatior ZnS(Ag)
Detecting nuclidesbull Alpha Pu-239 U-234 U-238bull Beta Sr-90+Y-90 F-18 Cs-137 Co-60 Tс-99 O-15
N-13 Sr-89 C-11 I-131 Na-22 Ru-106+Rh-106 Tl-204
bull Gamma Tc-99m I-123
Efficiencybull Alpha
Pu-239 40 U-234 25U-238 15
bull Beta Sr-90 +Y-90 40
Measurement range bull Alpha 1 divide 103 min-1cm-2 bull Beta 10 divide 103 min-1cm-2
bull Gamma 5103 divide 5106 min-1cm-2
Energy range bull Alpha 30 divide 80 MeV bull Beta 008 divide 35 MeV bull Gamma 005 divide 30 MeV
Operation temperature range bull Minus 10 divide +50 ordmС
Electrical characteristicsbull Power supply 220 V 50 Hz
Mechanical characteristicsOverall dimensions weight bull 740times750times1180 mm 45 kg
Versionsbull Withwithout alpha detectorbull Indication (min-1cm-2 ) or (Bqсm2)bull Detectors overall dimensions smbull Hand 178 х 235bull Foot 185 х 436
Whole body contamination monitor RZBA-04-04Mbull No gas supply neededbull Compensation for background gamma radiation
and contamination of detector unitsbull Individual threshold setting for each measure-
ment channelbull Visible and audible alarms ldquoCONTAMINATIONrdquo and
ldquoCLEANrdquo bull Indication of contaminated body parts on the
panel with image of the bodybull Optional remote alpha-detector
Physical characteristicsDetectors bull Beta - GM counters scintillatorsbull Alpha - scintillatior ZnS(Ag)
Measurement range bull Beta 5 divide 15000 min-1cm-2
bull Alpha 01 divide 10000 min-1cm-2
Energy range bull Beta 015 divide 25 MeV bull Alpha 40 divide 56 MeV
Operation temperature range bull +5 divide +50 ordmС
Electrical characteristicsPower supply bull 220 V 50 Hz
Interfaces bull RS-232bull RS-485
Mechanical characteristicsOverall dimensions weight bull 2650times940times930 mm 310 kg
Versionsbull Withwithout alpha detectorbull Indication (min-1cm-2 ) or (Bqсm2)
Reference standards Nuclear IEC 61098
RZBA-04-04MWHOLE BODY CONTAMINATION MONITOR
SPC ldquoDozardquoRadiation monitoring equipment
62 63
RZA-05DALPHA HAND-MONITOR
bull No gas supply needed bull Numeric and color (red green) indication of
control resultsbull LED sensor of hand- positioning for start of
measurementbull Audible alarm signals of the excess of preset
thresholdsbull Measurement value indication min-1cm-2 or
Bqсm2
Physical characteristicsDetectors alpha - scintillatior ZnS(Ag)
Efficiencybull Pu-239 20 bull U-234 14bull U-238 8
Measurement range bull 05 divide 105 min-1cm-2
Energy range bull 41 divide 90 MeV
Operation temperature range bull minus 10 divide +50 ordmС
Electrical characteristicsPower supply bull 220 V 50 Hz
Mechanical characteristicsOverall dimensions weight no more bull 740times1400times1450 mm 70 kg
Reference standards Nuclear IEC 61098
bull Simultaneous measurement of alphabeta activi-ties in the sample
bull Active shielding anti-coincidence background subtraction using GM counters
bull Lead shielding 30 mm
UMF-2000 LOW LEVEL ALPHA- BETA- COUNTER
Physical characteristicsDetectors bull Silicon specrometric detector 500 or 1000 mm2
Measurement range bull Alpha 001 divide 1000 Bq bull Beta 01 divide 3000 Bq
Energy range bull Alpha 35 divide 80 MeV bull Beta 005 divide 35 MeV
Electrical characteristicsPower supply bull 220 V 50 Hz
Interfaces bull RS-232bull USB
Mechanical characteristicsOverall dimensions weight bull 337times286times190 mm 22 kg
Versionsbull Detector area 500 mm2
bull Detector area 1000 mm2
UMF-2000 Detector area 1000 mm2
UMF-2000 Detector area 500 mm2
SpectraDec software for alpha-spectrometric measurements
SPC ldquoDozardquoRadiation monitoring equipment
64 65
DRK DOSE AREA PRODUCT METER
DRK-1bull Diagnostic reference level (DRL) of patients
determinationbull Suitable for all basic types of x-ray machines
Physical characteristicsDetector bull Plane-parallel ionization chamber
Measurement range bull 1 divide 104 cGycm2
Electrical characteristicsPower supply bull 220 V 50 Hz
DRK-1M-CTbull Measuring of dose length product
Physical characteristicsDetector bull Pencil Ionization Chamber
Measurement rangebull 05 divide 109 microGym
DRK-1Mbull Measuring of air kerma on sectional area of the
X-ray beam productbull Measuring of air kerma rate on area productbull Measuring of air kerma ratebull Measuring of air kerma
Physical characteristicsDetector bull Plane-parallel ionization chamber
Measurement rangebull 01 divide 109 microGym2
bull 06 divide 6104 microGym2cbull 30 divide 9105 microGycbull 30 divide 9991011 microGyReference standard IEC 60580 2003
bull Measurement of strontium-90 in the foodstuffs agricultural products etc
bull Measurement of gross beta activity in samplebull Self tests using built-in LED
ldquoPROGRESS-BETArdquo SCINTILLATION BETA SPECTROMETER
Physical characteristicsDetector bull Plastic scintillator Oslash70x10 mm
Sample bull Plate Oslash70 mmbull Weight up to 15 g
Energy range bull 02 divide 30 MeV
Minimum detectable activity of Sr-90 in a 10 g sample on a standard planchet Bqsamplebull In case of absence of K-40 in the sample 01 Bqbull In case the activity of K-40 till 5 Bqg 05 Bq
Electrical characteristics Interface bull USB
Mechanical characteristicsWeight bull No more 50 kg
Complete setBasic complete setbull Detector unit with plastic scintillator integrated
power supply amplifier ADC bull Lead shielding bull ldquoProgressrdquo software bull Сheck source for energetic calibration (Sr-90-Y-90) bull Planchet Oslash 70 mm (5 items) bull Sample dencification device bull Procedure manual for measurement of radio-
nuclidesrsquo activity using the scintillation beta spec-trometer ldquoProgressrdquo
Optional equipment and servicebull Personal computer and printer bull Calibrations for radionuclides not included in the
main library of radionuclides
Progress-Beta
Reference standards IEC 61562
SPC ldquoDozardquoRadiation monitoring equipment
66 67
bull Measurement of gamma activity in foodstuffs soil samples and others environmental objects
bull Identification of radionuclides in the sample bull Automatic correction for sample density bull Self-tests using built-in LED
ldquoPROGRESS-GAMMArdquoSCINTILLATION GAMMA SPECTROMETER
Physical characteristicsDetector bull NaI (Tl) Oslash63times63 mm
Validated measurement geometries bull Marinelli beakers (1 liter) Petri dishes (Oslash90 mm)
etc
Energy range bull 02 divide 30 MeV
Minimum detectable activity Bqsamplebull Cs-137 3 Bqbull Th-232 7 Bqbull Ra-226 8 Bq bull К-40 40 Bq
Electrical characteristics Interface bull USB
Mechanical characteristicsWeight bull No more 120 kg
Complete setBasic complete setbull Scintillation detector unit with NaI (Tl) detector
with integrated power supply amplifier and ADC bull Lead shielding 50 mm bull ldquoProgressrdquo software bull Сheck source for energy calibration (Cs-137 +
K-40)bull Marinelli beakers - 1 liter (5 items) bull Petri dishes Oslash 90 mm (5 items) bull Procedure manual for measurement of activity
of radionuclides using the scintillation gamma spectrometer ldquoProgressrdquo
Optional equipment and servicebull Kit for radon measurements including calibration
of ldquoIC-63rdquo geometry for counting the charcoal samples
bull Personal computer and printer bull Calibrations for user defined geometries bull Calibrations for radionuclides not included in the
main library of radionuclides
Progress-Gamma
Reference standards IEC 61563
ldquoPROGRESS-G(P)rdquoPORTABLE SCINTILLATION GAMMA SPECTROMETERbull Field measurements of gamma activity in environ-
mental objects without sampling (4π geometry)bull Laboratory measurement of gamma activity in
foodstuffs soil samples and others environmental objects
bull Identification of radionuclides in the sample bull Automatic correction for sample densitybull Tests using built-in LED
Physical charachteristicsDetector bull NaI (Tl) Oslash45times50 mmbull Lead shielding 20 mm
Validated measurement geometries bull Marinelli beakers (05 liter) Petri dishes (Oslash90 mm)
etc
Energy range bull 02 divide 30 MeV
Minimum detectable activity in 05-litre Marinelli beaker bull Cs-13710 Bqkgbull К-40100 Bqkgbull Ra-22618 Bqkg bull Th-23216 Bqkg
Minimum detectable activity in 30 min (4π geometry) bull Cs-137 2 Bqkgbull К-40 30 Bqkgbull Ra-226 4 Bqkg bull Th-232 3 Bqkg
Electrical characteristicsPower supply bull Rechargeable batterybull 220 V 50 Hz
Interface bull USB RS-232
Weight bull No more than 60 kg
Complete setBasic complete setbull Scinttillation detector unit with NaI(Tl) bull ldquoProgressrdquo softwarebull Сontrol unit ldquoSputnikrdquo for aquisition and analisys
of spectra with built-in memory for spectral databull Casebull Lead shielding (2 cm) for laboratory usebull 05-litre Marinelli beakers ndash 5 itemsbull Na-22 check sourcebull Power adapter BPS-01bull Operation manualbull Procedure manual for measurement of activity
of radionuclides using the scintillation gamma spectrometer ldquoProgressrdquo
Optional equipment and servicebull Kit for radon measurements with charcoalbull Built-in dose rate meterbull Additional memory (RAM) for storage of 64
spectrabull Additional power adapterbull Notebook and printer
Progress-Gamma
Reference standards IEC 61563
SPC ldquoDozardquoRadiation monitoring equipment
68 69
Physical characteristicsDetectorbull Scintillation detector ZnS (Oslash 60 mm)
Samplebull Thin sample - diameter up to 70 mm bull Preparation technique - electro-depositionbull Thick sample - diameter 70 mm weight
200300 mg bull Preparation technique - application of powders
(prepared by radiochemical concentration by water evaporation or by pounding of mineral samples) onto a planchet with the help of spirit
Energy rangebull 15 divide 8 MeV
Minimum detectable activitybull Thin samples no more than 910-3 Bqsamplebull Thick samples no more than 180 Bqkg
Mechanical characteristicsOverall dimensions weightbull 195times120times210 mm 34 kg
Complete setBasic complete setbull Alpha radiometer ldquoProgress-ARrdquobull Check source (uranium isotopes)
Set of accessoriesbull Procedure manual for measurements of radi-
oactivity using scintillation alpha radiometer ldquoProgress-ARrdquo
bull ldquoProgressrdquo software
ldquoProgress-ARrdquo
bull Measurement of gross activity of alpha emitting radionuclides in thin samples
bull Measurement of gross activity of alpha emitting radionuclides in thick samples
bull Measurement of activity deposited on aerosol filters
ldquoPROGRESS-ARrdquoALPHA RADIOMETER
Several fixed positions of the detector enable to perform measurements in various geometries and to estimate the content ofbull Cs-137 in the whole bodybull I-131 in thyroidbull Co-60 Cs-137 Mn-54 Cr-51 in lungsbull Database for storage of measurement data and
resultsbull Uncertainty calculations based on measurement
databull Self tests using built-in LED
ldquoPROGRESSrdquo WHOLE BODY COUNTER
Physical characteristicsDetectorbull scintillation detector NaI (Tl) Oslash63times63 mm
Energy rangebull 02 divide 28 MeV
Minimum detectable activitybull By Cs-137 in the whole body - 1200 Bqbull By I-131 in thyroid - 100 Bqbull By Co-60 Cs-137 Mn-54 Cr-51 in lungs - 200 Bq
Mechanical characteristicsWeight bull No more than 120 kg
Complete setBasic complete setbull Collimator with rotator and holderbull Detector with incorporated ADCbull Patient chair and table for collimatorbull Check source Na-22bull Procedure manual for lifetime measurement of
gamma-emitting radionuclidesrsquo activity in human body using the gamma-spectrometer of human radiation ldquoProgressrdquo
bull laquoProgressraquo software
Optional equipment and servicebull Program of internal radiation committed internal
radiation effective dose calculation by the stand-ard model
bull Background phantombull Personal computer and printer
Collimator with rotator and holder
SPC ldquoDozardquoRadiation monitoring equipment
70 71
bull Categorization of wastes for the purpose of fur-ther processing including wastes with unknown radionuclide composition
bull Measurements during the incoming waste inspec-tion (accepting for storage disposal)
bull Certification of unconditioned and conditioned wastes in closed containers without opening them (at nuclear plants or at facilities providing collection storage transportation conditioning processing temporal storage and final disposal of radioactive waste)
bull Activity measurement of extended objects in situ without opening the equipment
bull Activity measurement of extended objects after opening (for example assessment of tubes used for oil transportation)
MKG-01D ldquoSADOVNIKrdquoSPECTROMETRY SYSTEM
Physical charachteristicsDetectorbull Detector unit GEM (GMX) with HPGe detector and
multi-positioning cryostat CFG-PMOD4-7 with 7 litre Dewar
bull Dose rate probe BDMG-200
Energy range bull With GEM detector 004 divide 30 MeVbull With GMX detector 0005 divide 15 MeVbull Dose rate probe BDMG-200 ndash 005 divide 30 MeV
Measurement rangebull 110-7 divide 10 Svhbull Relative efficiency of detection (in photopeak) at
13325 MeV (Co-60) 10 divide 150
Electrical characteristicsPower supplybull 220 V 50 Hz
Interfacebull USB
Complete setBasic complete setbull Spectrometric detector unit GEM (GMX) with
HPGe detector and multi-positioning cryostat with 7 litre Dewar
bull Portable digital multichannel analyzer DigiDARTbull Dose rate probe BDMG-200bull Autonomous power supply unit with built-in
batterybull Industrial computer keyboardbull Laser range-finderbull Thermographic printerbull Web-camerabull Device equipped with stepper motor for position-
ing of the spectrometric detectorbull Calibration device with reference sources
(Am-241 Co-60 Ba-133 Eu-152) for energy calibration
bull Removable collimators with end capbull Measurement proceduresbull ldquoClasterrdquo software
bull Measurement of gross alpha activity of alpha-emitting radionuclides
bull Measurement of alpha-emitting radionuclides activity in thin-layer samples meeting alpha-spectrometry requirements
Physical characteristicsDetectorbull Silicon ion-implanted 450 mm2
bull Easy to decontaminate thin windowbull dead layer less than 015 μmbull Background count rate in the range 3 divide 9 MeVbull No more than 09 h-1cm-2 for 450 mm2 detector
Energy rangebull 2 divide 9 MeVbull Lower limit of measurement range (minimum
detectable activity) 01 Bqbull Background count rate no more than 100 counts
in 24 hours
Electrical characteristics Power supplybull 220 V 50 Hz
Interfacebull USB
Complete setBasic complete setbull Detector unit with vacuum measuring chamber
and vacuum control systembull Low noise vacuum pump (type 2FY-05B or
equivalent)bull Check sourcebull ldquoProgressrdquo softwarebull Vacuum tube
MKS-01A ldquoMULTIRAD-ASrdquoALPHA SPECTROMETER
SPC ldquoDozardquoRadiation monitoring equipment
72 73
UCRV-2AIRFLOW MONITOR
bull Monitor of the air flow through filter of centralized multichannel sampling system
bull Radiation monitoring system (RMS) integration for internal exposures determination
bull Volume and flow rate measurements of the air that have passed through a analytical filter
bull Bar-code for filter identificationbull Operation as either standalone unit or as a part of
the RMS
Physical characteristicsMeasurement range of air volume bull 001 divide 9999 m3
Operation temperature range bull minus 20 divide +50 ordmС
Electrical characteristicsPower supply bull 220 V 50 Hz
Interface bull RS-485
PVP-06PORTABLE AIR SAMPLER
Air Sampler PVP-06 is indispensable for monitoring the radiation situation where the concentration of radioactive aerosols in the air does not require a sta-tionary sampling equipment Sampling head PVP-06 provides easy change of filters and cartridges
Purposebull To monitor the concentration of radioactive aero-
sols in the air sites
Controlled aerosolsbull Alpha- and beta-active aerosolsbull Daughter products of decay of radon and thoronbull Iodine isotopes
Physical characteristicsTypes of filtersbull Aerosol AFA-RSP-20bull Iodine AFA SI-20
Flow rate bull 33∙10-4 ndash 233∙10-4 m3s (20 divide 140 l min)
Electrical characteristicsPower supply bull 220 V50 Hzbull The vehicle power supply 108 divide 145 Vbull Internal battery
Minimal working time on internal battery to recharge bull 8 hours
Power consumption (at a flow rate of 100 lmin) bull 40 VA
Environment characteristicsOperating temperature bull minus 10 divide +40 deg C
Maximum humidity bull 90
Pressure bull 860 to 1060 hPA
Noise generated by the pump bull lt 55 dBA at 1 m
Mechanical characteristicsDimensions weight bull 241 times 108 times 160 mm 28 kg
Case material bull Plastic
Complete setbull Air sampler PVP-06bull AC power adapterbull Filters AFA-RSP-20 - 100 pcsbull Packaging for filters - 40 pcsbull Casebull Operation manualbull Calibration certificate
Optional equimpient bull Kit for sampling sorption columns of activated
carbon Ř head of sorption columns with protective
covers Ř activated charcoal SKT-3 - 1 pkg (02 L) Ř charocoal samples SC-13 - 8 pcs
bull Car charger bull Tipod bull Shoulder strapbull Calibration stand bull Filters AFA SI-20 - 100 pcs
Consumablesbull Aerosol filters AFA RSP-20bull Iodine filters AFA SI-20
SPC ldquoDozardquoRadiation monitoring equipment
74 75
Calibration of gamma dose and dose rate meters
Calibration ofbull Ambient equivalent dose H(10) meters (Sv Svh)bull Personal equivalent dose Hp(10) meters (Sv Svh)bull Exposure dose X meters (R Rh)bull Two sources in irradiator bull Select source and collimator opening using
tumbler
UPG-P DESKTOP GAMMA BEAM IRRADIATOR
Physical characteristicsRange of reproduced dose rate bull 05 μSvh divide 10 mSvh (50 μRh divide 100 mRh)
Sources activities bull 6times106 6times108 Bq (02 20 mCi) Cs-137
Overall dimensions bull 1250times400times300 mm
Irradiator weight bull Not more than 37 kg
Calibration bench weight bull Not more than 15 kg
Reference standards IEC 60846 IEC 61526
Physical characteristicsDetectorbull Silicon
Measurement range EEC measurement bull Measurement range of radon EEC
10 divide 10bull106 Bqbullm-3
bull Measurement range of thoron EEC 05 divide 10bull104 Bqbullm-3
bull Air flow through the filter 100plusmn05 lmin
Concentration measurementbull Measurement range of radon-222 concentration
in air 10 divide 20bull106 cpsbull Measurement range of 216Po(ThA)
1bull10-3 divide 1bull102 cpsbull Air sampler flow rate
10plusmn02 lminbull Measurement range of radon-222 concentration
in water samples 6 divide 800 Bqbullkg-1
bull Measurement range of radon-222 flux from soil surface 20 divide 103 mBqsbullm2
bull Measurement range of radon-222 concentration with preliminary sampling of air using air sam-plers 20 divide 107 Bqbullm-3
bull Measurement range of radon-222 concentration in samples of soil air 103 divide 106 Bqbullm-3
Operation temperature range bull 1 divide 35 ordmC
Electrical characteristicsPower supply bull 80 VA
Mechanical characteristicsOverall dimensions weight bull 220times200times165 mm 36 kg
ldquoALPHARAD PLUSrdquoRADON THORON amp THEIR PROGENY MONITORbull Measurement of radon and thoron concentration
and effective equivalent concentration (EEC)bull In the airbull In the indoor air of residential public and industri-
al buildings and structuresbull Measurement of radon in drinking water sourcesbull Measurements of radon flux from the soil surface
at land plots allocated for construction of houses public buildings and industrial facilities
bull Measurements of radon concentration in soil air
Reference standards IEC 61577
SPC ldquoDozardquoRadiation monitoring equipment
76 77
UKPN-2M-D NEUTRON BEAM IRRADIATOR
Reference standards IEC 61005 61322
Calibration of neutron dose and dose rate meters
Calibration ofbull Ambient equivalent dose H(10) meters (Sv Svh)bull Personal equivalent dose Hp(10) meters (Sv Svh)bull Flux density of neutrons (cm-2∙s-1)bull Transfer container for temporary storage of
sources bull Red light signal of source working position
Physical carachteristicsRange of reproduced dose ratebull 20 divide 800 μSvh
Range of reproduced flux densitiesbull 10 divide 400 cm-2∙s-1
Type of a source in use bull Pu-Be
Activity of a source in usebull 24х1011 Bq (with density of 107 s-1)
Overall dimensions weight no morebull 3000x750x2000 mm 300 kg
Required room dimensionsbull not less than 7x3x3 m
Electrical characteristicsPower supply bull 220 V 50 Hz
Calibration of gamma dose and dose rate meters
Calibration ofbull Ambient equivalent dose H(10) meters (Sv Svh)bull Personal equivalent dose Hp(10) meters (Sv Svh)bull Exposure dose X meters (R Rh)bull Four sources in irradiator bull Select source and move to working position
return to storage position using special rodbull Transfer container for temporary storage of
sources bull Red light signal of source working position
UPGD-2M-DGAMMA BEAM IRRADIATOR
Physical characteristicsRange of reproduced dose rate bull 05 μSvh divide 50 mSvh (50 μRh divide 5 Rh)
Maximum activity of source bull 2times1011 Bq (50 Ci) Cs-137
Overall dimensionsbull Irradiator 800times500times500 mmbull Guide rails length 30 mbull Height 16 mbull Weight not more than 700 kgbull Required room dimensions not less than 7x3x3 m
Electrical characteristicsPower supply bull 220 V 50 Hz
UPGD-2M-D
Reference standards IEC 60846 IEC 61526 IEC 61066
SPC ldquoDozardquo
78 79
Contents
MEASURING UNITS
DBG-S11D wide range gamma area monitor 40
UDKS-100 gamma and X-ray area monitor 41
UDMN-100 neutron area monitor 41
ALARM UNITS
BAS-2 ldquoMICROrdquo external visual alarm 42
BZS-2 ldquoMicrordquo external audible alarm 42
Illuminated warning signs 43
ldquoImpulsrdquo external display unit 43
UIM-3D area monitor count rate meter 44
DKG-05D personal gamma dosimeter 46
DVS-02D gamma-neutron personal electronic dosimeter 47
DVGI-8D new pen-type personal ionization chamber dosimeters 48
DKG-02U ldquoARBITERrdquo wide range gamma-dosimeter 49
DKG-07D ldquoDROZDrdquo gamma-dosimeter 50
MKS-15D ldquoSNEGIRrdquo multi ndash purpose radiation survey meter 51
SRPS-05D gamma monitor 52
DOZA-TLD multipurpose TLD system 53
DKS-96 universal radiation survey meter 54
EXTERNAL PROBES ALPHA
Alpha BDZA-96 55
Alpha BDZA-96B 55
Alpha BDZA-96M 55
Alpha BDZA-96S 55
Alpha BDZA-96T 55
EXTERNAL PROBES BETA
Beta BDZB-96 56
Beta BDZB-99 56
Beta BDZB-96B 56
Beta BDZB-96S 56
EXTERNAL PROBES GAMMA
Gamma BDKS-96B 57
Gamma and beta BDKS-96S 57
Gamma BDMG-96 57
EXTERNAL PROBES GAMMA
Gamma-search BDVG-96 58
Gamma-search BDPG-96 58
ContentsRadiation monitoring systemldquoPELIKANrdquo Radiation monitoring system (RMS) 6
BDMG-101 high range gamma area monitor 10
DBG-S11D wide range gamma area monitor 11
BDRG-52 high range gamma area monitor for accident and post-accident conditions 12
UDGP-01 Liquid technological environments monitor 13
UDMN-100 neutron area monitor 14
UDKG-100 Wel Liquid gamma monitor 14
BOP-1M data processing and transmission unit 15
UDA-1AB particulate monitor 16
UDG-1B noble gas monitor 17
UDG-03D noble gas monitor 18
UDI-1B iodine monitor 19
UDGB-01 noble gasesH-3C-14 monitor 20
UDGP-01 steam generator leakage monitor 21
UPPVM air flow parameters monitor 22
ldquoIMPULSrdquo external display unit 23
BI-2 remote display amp alarm unit 24
BASBAS-1s external alarm 25
SKGAV stack monitor 26
RMS software 28
RMS workstation ndash operator console 29
Configurator software 29
RM RACK radiation monitoring rack 30
SRKS-01D criticality accident alarm system 32
ldquoATLANT-Mrdquo environmental radiation monitoring system 34
ldquoBREEZErdquo high-volume air sampler 35
ldquoGAMMA-SENSORrdquo gamma-survey system 36
Radiation monitoring equipmentAREA MONITOR ldquoFREGATrdquo 38
BPI-1D local display unit 39
80
Gamma-search BDPG-96M 58
Gamma BDKG-96 stainless steel casing for geologic applications well logging 59
EXTERNAL PROBES NEUTRON
Neutron BDMN-96 59
Neutron-search BDKN-96 59
RZB-05D Hand-foot-clothing monitor 60
RZBA-04-04M whole body contamination monitor 61
RZA-05D alpha hand-monitor 62
UMF-2000 low level alpha- beta- counter 63
DRK dose area product meter 64
ldquoPROGRESS-BETArdquo scintillation beta spectrometer 65
ldquoPROGRESS-GAMMArdquo scintillation gamma spectrometer 66
ldquoPROGRESS-G(P)rdquo portable scintillation gamma spectrometer 67
ldquoPROGRESS-ARrdquo alpha radiometer 68
ldquoPROGRESSrdquo whole body counter 69
MKG-01D ldquoSADOVNIKrdquo spectrometry system 70
MKS-01A ldquoMULTIRAD-ASrdquo alpha spectrometer 71
UCRV-2 airflow monitor 72
PVP-06 portable air sampler 73
ldquoALPHARAD PLUSrdquo radon thoron amp their progeny monitor 74
UPG-P desktop gamma beam irradiator 75
UPGD-2M-D gamma beam irradiator 76
UKPN-2M-D neutron beam irradiator 77
SPC ldquoDozardquoRadiation monitoring equipment
4140
Continuous automatic monitoring of the gamma- X-ray ambient dose equivalent rate
Physical characteristicsbull Detector tissue-equivalent plastic scintillator
Oslash 45times20 mm
Measurement range bull Dose rate measurement range 01 μSvh divide 1 Svh bull Energy range 0015 divide 10 MeV
Mechanical characteristicsbull Protection index IP65bull Paint decontaminable
Overall dimensions weightbull Oslash72times265 mm 15 kg
UDKS-100 GAMMA AND X-RAY AREA MONITOR
UDMN-100 NEUTRON AREA MONITOR
Physical characteristicsbull detector ndash scintillator ZnS(Ag) Li-6
Measurement range bull 01 μSvh divide 01 Svh
Energy range bull 0025 eV divide 100 MeV
Temperature range bull minus 45 divide +50 ordmC
Electrical characteristicsbull Interfaces RS-485
Mechanical characteristicsbull Protection index IP 65bull Paint decontaminable
Overall dimensions weight bull 428times258times347 mm 115 kg
Continuous automatic monitoring of the neutron-radiations ambient dose equivalent ratebull Spherical polyethylene moderator Oslash 239 mm
MEASURING UNITS
DBG-S11D WIDE RANGE GAMMA AREA MONITOR
Continuous automatic monitoring of the gamma- ambient dose equivalent rate
Physical characteristicsbull Detector ndash GM counters
Measurement rangebull DBG-S11D 01 μSvh divide 10 mSvhbull DBG-S11D-01 01 μSvh divide 10 Svhbull DBG-S11D-02 01 μSvh divide 100 Svh
Energy rangebull 005 divide 30 MeV
Temperature range bull minus 40 divide +50 ordmC
Electrical characteristicsbull Interfaces RS-485 USB
Mechanical characteristicsbull Protection index IP 68bull Paint decontaminable
Overall dimensions weightbull DBG-S11D Oslash 68times141 mm 065 kg bull DBG-S11D-01 Oslash 68times179 mm 07 kgbull DBG-S11D-02 Oslash 68times179 mm 07 kg
Versionsbull DBG-S11Dbull DBG-S11D-01bull DBG-S11D-02
Reference standards Nuclear IEC 60846 IEC 60532 EMC IEC 61010 IEC 61000-6-2 Seismic IEC 60980
SPC ldquoDozardquoRadiation monitoring equipment
4342
ALARM UNITS
Generation visual signals of the excess of preset thresholds
Physical characteristicsLength of communication cablebull up to 1200 mbull Alarm Visual alarm green yellow red
Electrical characteristicsbull Power supply +12 V
Mechanical characteristicsbull Protection index IP 23
Overall dimensions weight 160times84times41 mm 02 kg
BAS-2 ldquoMICROrdquo EXTERNAL VISUAL ALARM
Generation audible signals of the excess of preset thresholds
Physical characteristicsLength of communication cablebull up to 1200 mbull Audible alarm 80 divide 100 dB at a distance of 1 m
Electrical characteristicsbull Power supply +12 V
Mechanical characteristicsbull Protection index IP 23
Overall dimensions weight 160times84times41 mm 02 kg
BZS-2 ldquoMICROrdquo EXTERNAL AUDIBLE ALARM
Physical characteristicsLength of communication cablebull up to 1200 m
Electrical characteristicsbull Power supply 220 V 50 Hz
Mechanical characteristicsbull Protection index IP 23
Overall dimensions weight bull 330times110times20 mm 05 kg
Physical characteristicsLength of communication cablebull up to 1200 m
Character height bull ldquoImpuls-910-Rrdquo 100 mmbull ldquoImpuls-915-D4Srdquo 150 mmbull ldquoImpuls-927-D4Srdquo 270 mm
Operating temperature rangebull ldquoImpuls-910-Rrdquo 0 divide +50 degCbull ldquoImpuls-915-D4Srdquo ldquo-727-D4Srdquo minus 40 divide +50 degC
Electrical characteristicsbull Power supply 220 V 50 Hz
Mechanical characteristicsProtection index bull ldquoImpuls-910-R IP 44bull ldquoImpuls-915-D4Srdquo ldquo-727-D4Srdquo IP 65
Overall dimensions weight bull ldquoImpuls-910-Rrdquo 400times160times60 mm 3 kgbull ldquoImpuls-915-D4Srdquo 815times250times80 mm 5 kgbull ldquoImpuls-927-D4Srdquo 1250times330times80 mm 5 kg
ILLUMINATED WARNING SIGNS
ldquoIMPULSrdquo EXTERNAL DISPLAY UNIT
SPC ldquoDozardquoRadiation monitoring equipment
4544
Individual threshold setting for each measurement channel
Continuous area and process monitoring
Collect amp display data from two measurement chan-nels (units with RS-485 or analog pulses)
Audible and visual alarms on exceeding preset thresholds or status of connected devices
Individual threshold setting for each measurement channel
Switching on the external alarm or executive devices when any threshold is exceeded
The wide panel displays the following information bull Values of measured parameters as min-1∙cm-2
s-1∙cm-2 μSvhbull Diagnostic information about the status of con-
nected devicesbull Current date and timebull Position of measured values with respect to the
thresholds in the form of scales with green yellow and red zones
bull Time history (trend) for each measured value
Physical characteristics Measurement range bull Count rate up to 107 CPM (170 kHz)
Operating temperature range bull minus 20 divide +50 ordmC
Electrical characteristics bull Power supply 220 V bull Interfaces USB
Mechanical characteristics bull Protection index IP 65 bull Overall dimensions weight 222times164times73 mm
40 kg
UIM-3D AREA MONITOR COUNT RATE METER
Measurement of alpha radiation flux density
Detector unit BDZA-100 (70 cm2) Measurement range 01 divide 104 min-1∙cm-2
Detector unit BDZA-100B (300 cm2) Measurement range 01 divide 2103 min-1∙cm-2
Measurement of beta radiation flux density
Detector unit BDZB-100 (28 cm2) Measurement range 10 divide 105 min-1∙cm-2
Detector unit BDZB-100L (30 cm2) Measurement range 10 divide 104 min-1∙cm-2
Detector unit BDZB-11D (84 cm2) Measurement range 5 divide 15∙104 min-1∙m-2
OPTIONAL PROBESMeasurement of gamma radiation flux density
Detector units BDEG-03 Measurement range 4 divide 2000 s-1∙cm-2
Detector unit UDKG-100 for operation in the rocks ore liquid media and sludge Measurement range 40 divide 8000 s-1∙cm-2
Measurement of the ambient dose equivalent rate
Detector unit DBG-S11D Measurement range 01 μSvh divide 100 Svh
Measurement of neutron radiation ambient dose equivalent rate
Detector unit BDMN-100 Measurement range 01 μSvh divide 01 Svh
SPC ldquoDozardquoRadiation monitoring equipment
46 47Reference standards Nuclear IEC 61526
Measurement of gamma-radiation personal dose equivalent Hp(10)bull Stand-alone dosimeter or composed of dosimetric
system onebull Audible and visual alarmbull Large memory dose accumulation historiesbull Exclusion of unauthorized intervention in dosim-
etry operation
DKG-05D PERSONAL GAMMA DOSIMETER
Physical characteristicsDetectors bull Silicon
Measurement range bull Dose rate 1 μSvh divide 10 Svhbull Dose 01 μSv divide 15 Sv
Energy range bull 005 divide 30 MeV
Electrical characteristicsbull Power supply rechargeable NiMH battery 1
alcaline battery (type AAA)
Operation timebull Till recharging not less 400 hoursbull With one set batteries not less 1000 hours
Mechanical characteristicsOverall dimensions weight bull 47times26times87 mm (with clip) 70 g
Environmental characteristicsbull IP65bull Temperature range minus 20 divide +45 ordmCbull Humidity up to 98 at 35 ordmCbull Shock vibration and drop resistant
Alarmbull Excess of alarm thresholdsbull Warnings of self-test failure and battery discharge bull Audible alarm 80 dB at 40 cmbull Visual alarm blinking LED
Relative equipmentbull One dosimeter charger ZU-1Mbull Chargestorage cassetes KZU-28KZU-56bull ldquoSmart chargingrdquo feature extends battery life timebull DKG-05D reader US-05bull DKG-05D system reader DVS-01D
Reader-PC interfacebull US-05 USB bull DVS-01D Ethernet
KZU-28
Physical characteristicsDetectors bull Silicon Li-6
Gamma measurement range bull Dose rate 1 μSvh divide 10 Svhbull Dose 01 μSv divide 15 Sv
Gamma energy range bull 005 divide 60 MeV
Neutron measurement range bull Dose rate 1 μSvh divide 2 Svhbull Dose 20 μSv divide 15 Sv
Neutron energy range bull 0025 eV divide 20 MeV
Electrical characteristicsPower supply bull Rechargeable NiMH batterybull Operatiion time till recharging not less 200 hours
Mechanical characteristicsOverall dimensions weight bull 47times26times87 mm (with clip) 70 g
Environmental characteristicsbull IP65bull Temperature range minus 20 divide +40 ordmCbull Humidity up to 75 at 30 ordmCbull Shock vibration and drop resistant
Alarmbull Excess of alarm thresholds bull Warnings of self-test failure and battery discharge bull Audible alarm 80 dB at 40 cmbull Visual alarm blinking LED
Relative equipmentbull One dosimeter charger ZU-1Mbull Chargestorage cassetes KZU-28 KZU-56bull ldquoSmart chargingrdquo feature extends battery life timebull DVS-02D reader UZS-01Sbull DVS-02D system reader DVS-01D
Reader-PC interfacebull UZS-01S USB bull DVS-01D Ethernet
UZS-01DReference standards Nuclear IEC 61526
DVS-02D GAMMA-NEUTRON PERSONAL ELECTRONIC DOSIMETER
Measurement of gamma- and neutron radiations personal dose equivalent Hp(10)bull Stand-alone dosimeter or composed of dosimetric
system onebull Audible and visual alarmbull Large memory dose accumulation historiesbull Exclusion of unauthorized intervention in dosim-
etry operationbull Both albedo thermal neutrons and intermediate
fast neutrons registrationbull Usable in the fields of Pu(Be) Po(Be) Cf and other
neutron sources as well as near nuclear reactors without neutron spectrum estimation
SPC ldquoDozardquoRadiation monitoring equipment
48 49
Dosimeters DVG-03D
DVGI-8D NEW PEN-TYPE PERSONAL IONIZATION CHAMBER DOSIMETERS
Measurement of personal dose equivalent Hp(10) of gamma and X-ray radiationbull Hp(10) of continuous and pulsed gamma and
X-ray radiation bull Electronic reader KSU-1bull Dosimeter DVG-03D with electronic ID bull Personal dose histories in the readerrsquos memorybull Readerrsquos connection with PC for database main-
tenance
Physical characteristicsDetector bull Ionization chamber
Measurement range bull 001 mSv divide 25 mSv
Energy range bull 0015 divide 25 MeV
Temperature range bull Reader KSU-1 +10 divide +50 ordmСbull Dosimeter DVG-03D minus 40 divide +50 ordmС
Electrical characteristicsPower supply bull Reader KSU-1 220 V 50 Hz built-in batteries bull Dosimeter DVG-03D four batteries CR 1025 bull Batteries life 3 yearsbull Readers interfaces RS-232USB 20
Mechanical characteristicsOverall dimensions weightbull Dosimeter DVG-03D Oslash 18times126 mm 005 kgbull Reader KSU-1 235times232times125 mm 28 kg
Reference standards Nuclear IEC 62387-1
DKG-02U ldquoARBITERrdquo WIDE RANGE GAMMA-DOSIMETER
Physical characteristicsDetectors bull GM counters
Measurement rangebull Dose-rate 01 μSvh divide 3 Svhbull Dose 1 μSv divide 100 Sv
Energy range bull 005 divide 3 MeV
Electrical characteristicsbull Power supply 2 alcaline batteries (type AA)bull Batteries life not less 200 hours
Mechanical characteristicsOverall dimensions weight bull 152times82times32 mm 03 kg
Environmental characteristicsbull Temperature range minus 20 divide +50 ordmCbull Humidity up to 90 at +25 ordmCbull Shock vibration and drop resistant
Reference standards Nuclear IEC 60846
Measurement of gamma radiation ambient equiva-lent dose H(10) and dose rate H(10)bull Audible signals (clicks) for radiation condition
estimationbull Analog scale for search modebull Audible and visual alarms of the excess of preset
dose and dose rate thresholds bull Shock-resistant water-proof easy decontamina-
tion casebull 100 measurement results memory with date and
time of measurementbull Indication of total dose accumulated during
exploitation time bull Indication of measurement result statistical
uncertainty
SPC ldquoDozardquoRadiation monitoring equipment
50 51
Physical characteristicsDetectors bull GM counter
Measurement rangebull Dose-rate 01 μSvh divide 3 mSvhbull Dose 1 μSv divide 02 Sv
Energy range bull 005 divide 3 MeV
Temperature range bull Minus 20 divide +50 ordmC
Electrical characteristicsbull Power supply 2 alcaline batteries 15 V (type AA)bull Batteries life not less 200 hours
Mechanical characteristicsOverall dimensions weight bull 122times74times29 mm 025 kg
Reference standards Nuclear IEC 60846
DKG-07D ldquoDROZDrdquoGAMMA-DOSIMETER
Measurement of gamma radiation ambient equiva-lent dose H(10) and dose rate H(10)bull Two independent measurement channels dose
and dose ratebull Audible signals (clicks) for radiation condition
estimationbull Continuous measurement with updating meas-
urement resultbull Measurement result can be obtained with any
desired statistical uncertainty (error)bull Automatic restart when radiation level sharply
changesbull Indication of statistical uncertainty (error) during
measurement process
Continuous measurement with updating measure-ment result
Automatic restart when radiation level sharply changes bull Gamma dose H(10) and dose-rate H(10) meas-
urementbull Beta and gamma contamination surveybull Indication of statistical uncertainty during the
measurementbull Continuous measurement with accuracy increas-
ing with time bull Automatic restart triggered by change of gamma
dose-ratebull Compensation of gamma count rate while meas-
uring beta radiationbull Indication of battery charge levelbull Audible signal of the excess of preset threshold
Physical characteristicsDetectors bull GM counter
Measurement range bull Dose-rate 01 microSvh divide 20 mSvhbull Dose 1 microSv divide 100 Svbull Beta flux density (for Sr-90+Y-90)
10 divide 105 cm-2 min-1
Energy range bull Gamma 005 divide 3 MeVbull Beta 01 divide 3 MeV
Temperature range bull Minus 20 divide +50 ordmC
MKS-15D ldquoSnegirrdquo backside
MKS-15D ldquoSNEGIRrdquoMULTI ndash PURPOSE RADIATION SURVEY METER
Reference standards Nuclear IEC 60846 IEC 60325
Electrical characteristicsbull Power supply 2 alcaline batteries (type AA)bull Battery life not less 400 hours
Mechanical characteristicsOverall dimensions weight bull 124times72times35 mm 035 kg
SPC ldquoDozardquoRadiation monitoring equipment
52 53
Physical characteristicsDetectorbull GM counter
Measurement range bull 01 μSvh divide 20 mSvh
Energy range bull 005 divide 30 MeV
Threshold setting range bull 03 μSvh divide 20 mSvh
Step change of the thresholdbull In the range 03 divide 10 μSvh with the step
001 μSvhbull In the range 10 divide 100 μSvh with the step
01 μSvhbull In the range 100 divide 2000 μSvh with the step
10 μSvh
Electrical characteristicsPower supply bull 220 V 50 Hz bull Relay output
Mechanical characteristicsProtection index bull IP 40
Overall dimensions weight bull 226times120times75 mm 07 kg
Alarmbull Sound alarm 80 divide 100 dBA at distance 1 mbull Visual alarm redbull Connection of the external alarm signaling unit
Reference standards Nuclear IEC 60846 IEC 60532
Continuous automatic monitoring of the ambient dose equivalent rate bull Measurement of gamma dose rate H(10)bull Audible and visual alarm signals for preset
thresholdsbull Switching on the external signaling or executive
devices
SRPS-05D GAMMA MONITOR
Measurement ofbull Gamma and X-ray personal dose equivalent
Hp(10)bull Neutron personal dose equivalent Hp(10)bull Lens dose equivalent Hp(3)bull Skin dose equivalent Hp(007)bull TLD reader day-to-day tests using built-in LEDbull No needs nitrogen for heating
Physical charachteristicsDetectors bull 7LiF Mg Ti (gamma beta)bull 6LiF Mg Ti (neutron)
Gamma and X-ray Hp(10) Measurement range bull 500 μSv divide 10 Sv
Energy range bull 0015 divide 30 MeV
Neutron Hp(10)Measurement range bull 01 mSv divide 100 mSv
Energy range bull 0025 eV divide 10 MeV
Beta and photons Hp(007) Hp(3) Measurement range bull 2 mSv divide 100 Sv
Energy range bull Beta 025 divide 35 MeVbull Photons lt15 keV
Mechanical characteristicsDosimeters overall dimensions weight bull Gamma Hp(10) DTL-2 holder - 62times26times16 mm
16 gbull DTU holder - 42times28times18 mm 8 gbull Lens Hp(3) face skin Hp(007) Oslash 32times16 mm 9 gbull Finger skin Hp(007) 90times20times2 mm 1 gbull Neutron gamma Hp(10) 48times40times20 mm 30 g
Reference standards Nuclear IEC 61066
DTL-2 DTU-2
MKD (A-type) DVNG-M
DOZA-TLD MULTIPURPOSE TLD SYSTEM
SPC ldquoDozardquoRadiation monitoring equipment
54 55
Continuous and pulsed gamma and X-ray dose H(10) and dose-rate measurementbull Alpha beta and gamma contamination surveybull Neutron dose H(10) and dose-rate measurementbull Gamma radiation flux density in boreholes and
liquid media measurement
Electrical characteristicsPower supply bull UIK-05 four C-size batteriesbull UIK-05-01 rechargeable batterybull UIK-06 rechargeable battery
Interfaces bull RS-232bull USB (via adapter)
bull Detector type automatic determination and corre-sponding measurement modes selection
bull Alarm threshold settings ndash for dose dose-rate alpha and beta contaminations
bull ldquoDetectrdquo and ldquoLocaterdquo modes for survey probes
Reference standards Nuclear IEC 60846 IEC 60325 IEC 61005 IEC 62363
Case
UIK-06 control unit165times78times48 mm 03 kg
DKS-96UNIVERSAL RADIATION SURVEY METER
UIK-05 control unit202times86times90 mm 10 kg
BDZA-96
BDZA-96B
BDZA-96M
BDZA-96S
BDZA-96T
EXTERNAL PROBES ALPHAALPHA BDZA-96Detector bull ZnS(Ag) 70 cm2
Measurement range (for Pu-239)bull 01 divide 104 min-1cm-2
Overall dimensions weightbull Oslash 130times240 mm 11 kg
ALPHA BDZA-96BDetector bull ZnS(Ag) 300 сm2
Measurement range (for Pu-239)bull 01 divide 2103 min-1cm-2
Overall dimensions weightbull Oslash 230times290 mm 40 kg
ALPHA BDZA-96MDetector bull ZnS(Ag) 10 сm2
Measurement range (for Pu-239)bull 01 divide 105 min-1cm-2
Overall dimensions weightbull Oslash 65times240 mm 09 kg
ALPHA BDZA-96SDetector bull ZnS(Ag) 30 сm2
Measurement range (for Pu-239)bull 01 divide 5104 min-1cm-2
Overall dimensions weightbull Oslash 90times240 mm 10 kg
ALPHA BDZA-96TDetector bull Silicon 5 сm2
Measurement range (for Pu-239)bull 01 divide 106 min-1cm-2
Overall dimensions weightbull Oslash 50times60 mm 015 kg
SPC ldquoDozardquoRadiation monitoring equipment
56 57
BETA BDZB-96Detector Scintillator 28 сm2
Measurement range (for Sr-90+Y-90)bull 10 divide 105 min-1cm-2
Energy rangebull 03 divide 30 MeV
Overall dimensions weightbull Oslash 90times230 mm 09 kg
BETA BDZB-99Detector bull GM counter 30 сm2
Measurement range (for Sr-90+Y-90)bull 20 divide 104 min-1см-2
Energy rangebull 012 divide 30 MeV
Overall dimensions weightbull Oslash 88times80 mm 04 kgbull Telescopic pole length 07 m
BETA BDZB-96BDetector bull GM counter 80 сm2
Measurement range (for Sr-90+Y-90)bull 3 divide 104 min-1сm-2
Energy rangebull 012 divide 30 MeV
Overall dimensions weightbull 150times200times110 mm 15 kg
BETA BDZB-96Sbull Detector GM counter 15 сm2
Measurement range (for Sr-90+Y-90)bull 10 divide 3104 min-1cm-2
Energy rangebull 012 divide 30 MeV
Overall dimensions weightbull Oslash 65times65 mm 03 kgbull Telescopic pole length 07 m
BDZB-96
BDZB-99
BDZB-96B
BDZB-96S
EXTERNAL PROBES BETA
GAMMA BDKS-96BDetector bull Tissue-equivalent scintillator Oslash 45times20 mm
Measurement rangebull Dose rate H(10) 01 μSvh divide 1 Svhbull Dose H(10) 01 μSv divide 10 Sv
Energy rangebull 0015 divide 10 MeV
Overall dimensions weightbull Oslash 60times250 mm 085 kg
GAMMA AND BETA BDKS-96SDetector bull Double GM counters
Measurement rangebull Gamma dose rate H(10) 01 μSvh divide 1 mSvhbull Gamma dose H(10) 01 μSv divide 10 Svbull Beta 10 divide 3104 min-1cm-2
Energy rangebull Gamma 005 divide 3 MeVbull Beta 012 divide 3 MeV
Overall dimensions weightbull Oslash 80times80 mm 035 kgbull Telescopic pole length 07 m
GAMMA BDMG-96Detector bull GM counters
Measurement rangebull Dose rate H(10) 01 μSvh divide 10 Svhbull Dose H(10) 01 μSv divide 10 Sv
Energy range bull 005 divide 3 MeV
Overall dimensions weightbull 40times250 mm 05 kgbull Telescopic pole length 07 m 4 m (by request)
EXTERNAL PROBES GAMMA
BDKS-96B
BDMG-96
BDKS-96S
SPC ldquoDozardquoRadiation monitoring equipment
58 59
GAMMA-SEARCH BDVG-96Detector bull Scintillator NaI(Tl) Oslash 63times63 mm
Measurement rangebull Flux density measurement range 4 divide 2000 s-1cm-2
bull Dose rate H(10) for Cs-137 01 divide 30 μSvhbull Sensitivity for Cs-137 3000 (pulsess-1)( μSvh-1)
Overall dimensions weightbull Oslash 88times400 mm 20 kgbull Modular pole length 16 m
GAMMA-SEARCH BDPG-96Detector bull Scintillator NaI(Tl) Oslash 25times40 mm
Measurement rangebull Flux density measurement range 10 divide 8000 s-1cm-2
bull Dose rate H(10) for Cs-137 01 divide 100 μSvhbull Sensitivity for Cs-137 500 (pulsess-1)( μSvh-1)
Overall dimensions weightbull 50times190times480 mm 10 kgbull Telescopic pole length 07 m
GAMMA-SEARCH BDPG-96MDetector bull Scintillator NaI(Tl) Oslash 18times30 mm
Measurement rangebull Flux density measurement range 10 divide 24000 s-1cm-2
bull Dose rate H(10) for Cs-137 01 divide 300 μSvhbull Sensitivity for Cs-137 200 (pulsess-1)( μSvh-1)
Overall dimensions weightbull Oslash 35times320 mm 05 kgbull Telescopic pole length 07 or 38 m
EXTERNAL PROBES GAMMA
BDVG-96
BDPG-96M
BDPG-96
EXTERNAL PROBESGAMMA BDKG-96 STAINLESS STEEL CASING FOR GEOLOGIC APPLICATIONS WELL LOGGINGDetector bull Scintillator NaI(Tl) Oslash 18times30 mm
Measurement rangebull Flux density measurement range 10 divide 105 s-1cm-2
bull Dose rate H(10) for Cs-137 5 divide 2104 μRhbull Sensitivity for Cs-137 200 (pulsess-1)( μSvh-1)
Overall dimensions weightbull Oslash 38times535 mm 36 kgbull Cable length 10 divide 1000 m
NEUTRON BDMN-96Detector bull Scintillator with ZnS(Ag)
Measurement rangebull Dose rate H(10) 01 μSvh divide 01 Svhbull Dose H(10) 01 μSv divide 10 Sv
Energy range bull 0025 eV divide 10 MeV
Overall dimensions weightbull Detector Oslash 54times200 mm 08 kgbull Moderator Oslash 245 mm 73 kg
NEUTRON-SEARCH BDKN-96Detector bull He-3 counter in polyethilene moderator
Measurement rangebull Dose rate H(10) for Pu-Be 01 μSvh divide 01 Svhbull Dose H(10) for Pu-Be 01 μSv divide 10 Sv
Energy range bull 0025 eV divide 14 MeV
Overall dimensions weightbull 295times142times100 mm 225 kg
BDKG-96M
BDMN-96
BDKN-96
SPC ldquoDozardquoRadiation monitoring equipment
60 61
bull No gas supply neededbull Clothing control detachable right hand detector bull Alpha detector optional connection bull Numeric and color (red green) indication of
control resultsbull LED sensor of hand-foot positioning for start of
measurementbull Automatic compensation of gamma background
and contamination of detectorbull Audible alarm signals of the excess of preset
thresholdsbull Measurement value indication min-1cm-2 or
Bqсm2
Reference standards Nuclear IEC 61098
RZB-05D HAND-FOOT-CLOTHING MONITOR
Physical characteristicsDetectors bull Gamma beta - GM countersbull Alpha - scintillatior ZnS(Ag)
Detecting nuclidesbull Alpha Pu-239 U-234 U-238bull Beta Sr-90+Y-90 F-18 Cs-137 Co-60 Tс-99 O-15
N-13 Sr-89 C-11 I-131 Na-22 Ru-106+Rh-106 Tl-204
bull Gamma Tc-99m I-123
Efficiencybull Alpha
Pu-239 40 U-234 25U-238 15
bull Beta Sr-90 +Y-90 40
Measurement range bull Alpha 1 divide 103 min-1cm-2 bull Beta 10 divide 103 min-1cm-2
bull Gamma 5103 divide 5106 min-1cm-2
Energy range bull Alpha 30 divide 80 MeV bull Beta 008 divide 35 MeV bull Gamma 005 divide 30 MeV
Operation temperature range bull Minus 10 divide +50 ordmС
Electrical characteristicsbull Power supply 220 V 50 Hz
Mechanical characteristicsOverall dimensions weight bull 740times750times1180 mm 45 kg
Versionsbull Withwithout alpha detectorbull Indication (min-1cm-2 ) or (Bqсm2)bull Detectors overall dimensions smbull Hand 178 х 235bull Foot 185 х 436
Whole body contamination monitor RZBA-04-04Mbull No gas supply neededbull Compensation for background gamma radiation
and contamination of detector unitsbull Individual threshold setting for each measure-
ment channelbull Visible and audible alarms ldquoCONTAMINATIONrdquo and
ldquoCLEANrdquo bull Indication of contaminated body parts on the
panel with image of the bodybull Optional remote alpha-detector
Physical characteristicsDetectors bull Beta - GM counters scintillatorsbull Alpha - scintillatior ZnS(Ag)
Measurement range bull Beta 5 divide 15000 min-1cm-2
bull Alpha 01 divide 10000 min-1cm-2
Energy range bull Beta 015 divide 25 MeV bull Alpha 40 divide 56 MeV
Operation temperature range bull +5 divide +50 ordmС
Electrical characteristicsPower supply bull 220 V 50 Hz
Interfaces bull RS-232bull RS-485
Mechanical characteristicsOverall dimensions weight bull 2650times940times930 mm 310 kg
Versionsbull Withwithout alpha detectorbull Indication (min-1cm-2 ) or (Bqсm2)
Reference standards Nuclear IEC 61098
RZBA-04-04MWHOLE BODY CONTAMINATION MONITOR
SPC ldquoDozardquoRadiation monitoring equipment
62 63
RZA-05DALPHA HAND-MONITOR
bull No gas supply needed bull Numeric and color (red green) indication of
control resultsbull LED sensor of hand- positioning for start of
measurementbull Audible alarm signals of the excess of preset
thresholdsbull Measurement value indication min-1cm-2 or
Bqсm2
Physical characteristicsDetectors alpha - scintillatior ZnS(Ag)
Efficiencybull Pu-239 20 bull U-234 14bull U-238 8
Measurement range bull 05 divide 105 min-1cm-2
Energy range bull 41 divide 90 MeV
Operation temperature range bull minus 10 divide +50 ordmС
Electrical characteristicsPower supply bull 220 V 50 Hz
Mechanical characteristicsOverall dimensions weight no more bull 740times1400times1450 mm 70 kg
Reference standards Nuclear IEC 61098
bull Simultaneous measurement of alphabeta activi-ties in the sample
bull Active shielding anti-coincidence background subtraction using GM counters
bull Lead shielding 30 mm
UMF-2000 LOW LEVEL ALPHA- BETA- COUNTER
Physical characteristicsDetectors bull Silicon specrometric detector 500 or 1000 mm2
Measurement range bull Alpha 001 divide 1000 Bq bull Beta 01 divide 3000 Bq
Energy range bull Alpha 35 divide 80 MeV bull Beta 005 divide 35 MeV
Electrical characteristicsPower supply bull 220 V 50 Hz
Interfaces bull RS-232bull USB
Mechanical characteristicsOverall dimensions weight bull 337times286times190 mm 22 kg
Versionsbull Detector area 500 mm2
bull Detector area 1000 mm2
UMF-2000 Detector area 1000 mm2
UMF-2000 Detector area 500 mm2
SpectraDec software for alpha-spectrometric measurements
SPC ldquoDozardquoRadiation monitoring equipment
64 65
DRK DOSE AREA PRODUCT METER
DRK-1bull Diagnostic reference level (DRL) of patients
determinationbull Suitable for all basic types of x-ray machines
Physical characteristicsDetector bull Plane-parallel ionization chamber
Measurement range bull 1 divide 104 cGycm2
Electrical characteristicsPower supply bull 220 V 50 Hz
DRK-1M-CTbull Measuring of dose length product
Physical characteristicsDetector bull Pencil Ionization Chamber
Measurement rangebull 05 divide 109 microGym
DRK-1Mbull Measuring of air kerma on sectional area of the
X-ray beam productbull Measuring of air kerma rate on area productbull Measuring of air kerma ratebull Measuring of air kerma
Physical characteristicsDetector bull Plane-parallel ionization chamber
Measurement rangebull 01 divide 109 microGym2
bull 06 divide 6104 microGym2cbull 30 divide 9105 microGycbull 30 divide 9991011 microGyReference standard IEC 60580 2003
bull Measurement of strontium-90 in the foodstuffs agricultural products etc
bull Measurement of gross beta activity in samplebull Self tests using built-in LED
ldquoPROGRESS-BETArdquo SCINTILLATION BETA SPECTROMETER
Physical characteristicsDetector bull Plastic scintillator Oslash70x10 mm
Sample bull Plate Oslash70 mmbull Weight up to 15 g
Energy range bull 02 divide 30 MeV
Minimum detectable activity of Sr-90 in a 10 g sample on a standard planchet Bqsamplebull In case of absence of K-40 in the sample 01 Bqbull In case the activity of K-40 till 5 Bqg 05 Bq
Electrical characteristics Interface bull USB
Mechanical characteristicsWeight bull No more 50 kg
Complete setBasic complete setbull Detector unit with plastic scintillator integrated
power supply amplifier ADC bull Lead shielding bull ldquoProgressrdquo software bull Сheck source for energetic calibration (Sr-90-Y-90) bull Planchet Oslash 70 mm (5 items) bull Sample dencification device bull Procedure manual for measurement of radio-
nuclidesrsquo activity using the scintillation beta spec-trometer ldquoProgressrdquo
Optional equipment and servicebull Personal computer and printer bull Calibrations for radionuclides not included in the
main library of radionuclides
Progress-Beta
Reference standards IEC 61562
SPC ldquoDozardquoRadiation monitoring equipment
66 67
bull Measurement of gamma activity in foodstuffs soil samples and others environmental objects
bull Identification of radionuclides in the sample bull Automatic correction for sample density bull Self-tests using built-in LED
ldquoPROGRESS-GAMMArdquoSCINTILLATION GAMMA SPECTROMETER
Physical characteristicsDetector bull NaI (Tl) Oslash63times63 mm
Validated measurement geometries bull Marinelli beakers (1 liter) Petri dishes (Oslash90 mm)
etc
Energy range bull 02 divide 30 MeV
Minimum detectable activity Bqsamplebull Cs-137 3 Bqbull Th-232 7 Bqbull Ra-226 8 Bq bull К-40 40 Bq
Electrical characteristics Interface bull USB
Mechanical characteristicsWeight bull No more 120 kg
Complete setBasic complete setbull Scintillation detector unit with NaI (Tl) detector
with integrated power supply amplifier and ADC bull Lead shielding 50 mm bull ldquoProgressrdquo software bull Сheck source for energy calibration (Cs-137 +
K-40)bull Marinelli beakers - 1 liter (5 items) bull Petri dishes Oslash 90 mm (5 items) bull Procedure manual for measurement of activity
of radionuclides using the scintillation gamma spectrometer ldquoProgressrdquo
Optional equipment and servicebull Kit for radon measurements including calibration
of ldquoIC-63rdquo geometry for counting the charcoal samples
bull Personal computer and printer bull Calibrations for user defined geometries bull Calibrations for radionuclides not included in the
main library of radionuclides
Progress-Gamma
Reference standards IEC 61563
ldquoPROGRESS-G(P)rdquoPORTABLE SCINTILLATION GAMMA SPECTROMETERbull Field measurements of gamma activity in environ-
mental objects without sampling (4π geometry)bull Laboratory measurement of gamma activity in
foodstuffs soil samples and others environmental objects
bull Identification of radionuclides in the sample bull Automatic correction for sample densitybull Tests using built-in LED
Physical charachteristicsDetector bull NaI (Tl) Oslash45times50 mmbull Lead shielding 20 mm
Validated measurement geometries bull Marinelli beakers (05 liter) Petri dishes (Oslash90 mm)
etc
Energy range bull 02 divide 30 MeV
Minimum detectable activity in 05-litre Marinelli beaker bull Cs-13710 Bqkgbull К-40100 Bqkgbull Ra-22618 Bqkg bull Th-23216 Bqkg
Minimum detectable activity in 30 min (4π geometry) bull Cs-137 2 Bqkgbull К-40 30 Bqkgbull Ra-226 4 Bqkg bull Th-232 3 Bqkg
Electrical characteristicsPower supply bull Rechargeable batterybull 220 V 50 Hz
Interface bull USB RS-232
Weight bull No more than 60 kg
Complete setBasic complete setbull Scinttillation detector unit with NaI(Tl) bull ldquoProgressrdquo softwarebull Сontrol unit ldquoSputnikrdquo for aquisition and analisys
of spectra with built-in memory for spectral databull Casebull Lead shielding (2 cm) for laboratory usebull 05-litre Marinelli beakers ndash 5 itemsbull Na-22 check sourcebull Power adapter BPS-01bull Operation manualbull Procedure manual for measurement of activity
of radionuclides using the scintillation gamma spectrometer ldquoProgressrdquo
Optional equipment and servicebull Kit for radon measurements with charcoalbull Built-in dose rate meterbull Additional memory (RAM) for storage of 64
spectrabull Additional power adapterbull Notebook and printer
Progress-Gamma
Reference standards IEC 61563
SPC ldquoDozardquoRadiation monitoring equipment
68 69
Physical characteristicsDetectorbull Scintillation detector ZnS (Oslash 60 mm)
Samplebull Thin sample - diameter up to 70 mm bull Preparation technique - electro-depositionbull Thick sample - diameter 70 mm weight
200300 mg bull Preparation technique - application of powders
(prepared by radiochemical concentration by water evaporation or by pounding of mineral samples) onto a planchet with the help of spirit
Energy rangebull 15 divide 8 MeV
Minimum detectable activitybull Thin samples no more than 910-3 Bqsamplebull Thick samples no more than 180 Bqkg
Mechanical characteristicsOverall dimensions weightbull 195times120times210 mm 34 kg
Complete setBasic complete setbull Alpha radiometer ldquoProgress-ARrdquobull Check source (uranium isotopes)
Set of accessoriesbull Procedure manual for measurements of radi-
oactivity using scintillation alpha radiometer ldquoProgress-ARrdquo
bull ldquoProgressrdquo software
ldquoProgress-ARrdquo
bull Measurement of gross activity of alpha emitting radionuclides in thin samples
bull Measurement of gross activity of alpha emitting radionuclides in thick samples
bull Measurement of activity deposited on aerosol filters
ldquoPROGRESS-ARrdquoALPHA RADIOMETER
Several fixed positions of the detector enable to perform measurements in various geometries and to estimate the content ofbull Cs-137 in the whole bodybull I-131 in thyroidbull Co-60 Cs-137 Mn-54 Cr-51 in lungsbull Database for storage of measurement data and
resultsbull Uncertainty calculations based on measurement
databull Self tests using built-in LED
ldquoPROGRESSrdquo WHOLE BODY COUNTER
Physical characteristicsDetectorbull scintillation detector NaI (Tl) Oslash63times63 mm
Energy rangebull 02 divide 28 MeV
Minimum detectable activitybull By Cs-137 in the whole body - 1200 Bqbull By I-131 in thyroid - 100 Bqbull By Co-60 Cs-137 Mn-54 Cr-51 in lungs - 200 Bq
Mechanical characteristicsWeight bull No more than 120 kg
Complete setBasic complete setbull Collimator with rotator and holderbull Detector with incorporated ADCbull Patient chair and table for collimatorbull Check source Na-22bull Procedure manual for lifetime measurement of
gamma-emitting radionuclidesrsquo activity in human body using the gamma-spectrometer of human radiation ldquoProgressrdquo
bull laquoProgressraquo software
Optional equipment and servicebull Program of internal radiation committed internal
radiation effective dose calculation by the stand-ard model
bull Background phantombull Personal computer and printer
Collimator with rotator and holder
SPC ldquoDozardquoRadiation monitoring equipment
70 71
bull Categorization of wastes for the purpose of fur-ther processing including wastes with unknown radionuclide composition
bull Measurements during the incoming waste inspec-tion (accepting for storage disposal)
bull Certification of unconditioned and conditioned wastes in closed containers without opening them (at nuclear plants or at facilities providing collection storage transportation conditioning processing temporal storage and final disposal of radioactive waste)
bull Activity measurement of extended objects in situ without opening the equipment
bull Activity measurement of extended objects after opening (for example assessment of tubes used for oil transportation)
MKG-01D ldquoSADOVNIKrdquoSPECTROMETRY SYSTEM
Physical charachteristicsDetectorbull Detector unit GEM (GMX) with HPGe detector and
multi-positioning cryostat CFG-PMOD4-7 with 7 litre Dewar
bull Dose rate probe BDMG-200
Energy range bull With GEM detector 004 divide 30 MeVbull With GMX detector 0005 divide 15 MeVbull Dose rate probe BDMG-200 ndash 005 divide 30 MeV
Measurement rangebull 110-7 divide 10 Svhbull Relative efficiency of detection (in photopeak) at
13325 MeV (Co-60) 10 divide 150
Electrical characteristicsPower supplybull 220 V 50 Hz
Interfacebull USB
Complete setBasic complete setbull Spectrometric detector unit GEM (GMX) with
HPGe detector and multi-positioning cryostat with 7 litre Dewar
bull Portable digital multichannel analyzer DigiDARTbull Dose rate probe BDMG-200bull Autonomous power supply unit with built-in
batterybull Industrial computer keyboardbull Laser range-finderbull Thermographic printerbull Web-camerabull Device equipped with stepper motor for position-
ing of the spectrometric detectorbull Calibration device with reference sources
(Am-241 Co-60 Ba-133 Eu-152) for energy calibration
bull Removable collimators with end capbull Measurement proceduresbull ldquoClasterrdquo software
bull Measurement of gross alpha activity of alpha-emitting radionuclides
bull Measurement of alpha-emitting radionuclides activity in thin-layer samples meeting alpha-spectrometry requirements
Physical characteristicsDetectorbull Silicon ion-implanted 450 mm2
bull Easy to decontaminate thin windowbull dead layer less than 015 μmbull Background count rate in the range 3 divide 9 MeVbull No more than 09 h-1cm-2 for 450 mm2 detector
Energy rangebull 2 divide 9 MeVbull Lower limit of measurement range (minimum
detectable activity) 01 Bqbull Background count rate no more than 100 counts
in 24 hours
Electrical characteristics Power supplybull 220 V 50 Hz
Interfacebull USB
Complete setBasic complete setbull Detector unit with vacuum measuring chamber
and vacuum control systembull Low noise vacuum pump (type 2FY-05B or
equivalent)bull Check sourcebull ldquoProgressrdquo softwarebull Vacuum tube
MKS-01A ldquoMULTIRAD-ASrdquoALPHA SPECTROMETER
SPC ldquoDozardquoRadiation monitoring equipment
72 73
UCRV-2AIRFLOW MONITOR
bull Monitor of the air flow through filter of centralized multichannel sampling system
bull Radiation monitoring system (RMS) integration for internal exposures determination
bull Volume and flow rate measurements of the air that have passed through a analytical filter
bull Bar-code for filter identificationbull Operation as either standalone unit or as a part of
the RMS
Physical characteristicsMeasurement range of air volume bull 001 divide 9999 m3
Operation temperature range bull minus 20 divide +50 ordmС
Electrical characteristicsPower supply bull 220 V 50 Hz
Interface bull RS-485
PVP-06PORTABLE AIR SAMPLER
Air Sampler PVP-06 is indispensable for monitoring the radiation situation where the concentration of radioactive aerosols in the air does not require a sta-tionary sampling equipment Sampling head PVP-06 provides easy change of filters and cartridges
Purposebull To monitor the concentration of radioactive aero-
sols in the air sites
Controlled aerosolsbull Alpha- and beta-active aerosolsbull Daughter products of decay of radon and thoronbull Iodine isotopes
Physical characteristicsTypes of filtersbull Aerosol AFA-RSP-20bull Iodine AFA SI-20
Flow rate bull 33∙10-4 ndash 233∙10-4 m3s (20 divide 140 l min)
Electrical characteristicsPower supply bull 220 V50 Hzbull The vehicle power supply 108 divide 145 Vbull Internal battery
Minimal working time on internal battery to recharge bull 8 hours
Power consumption (at a flow rate of 100 lmin) bull 40 VA
Environment characteristicsOperating temperature bull minus 10 divide +40 deg C
Maximum humidity bull 90
Pressure bull 860 to 1060 hPA
Noise generated by the pump bull lt 55 dBA at 1 m
Mechanical characteristicsDimensions weight bull 241 times 108 times 160 mm 28 kg
Case material bull Plastic
Complete setbull Air sampler PVP-06bull AC power adapterbull Filters AFA-RSP-20 - 100 pcsbull Packaging for filters - 40 pcsbull Casebull Operation manualbull Calibration certificate
Optional equimpient bull Kit for sampling sorption columns of activated
carbon Ř head of sorption columns with protective
covers Ř activated charcoal SKT-3 - 1 pkg (02 L) Ř charocoal samples SC-13 - 8 pcs
bull Car charger bull Tipod bull Shoulder strapbull Calibration stand bull Filters AFA SI-20 - 100 pcs
Consumablesbull Aerosol filters AFA RSP-20bull Iodine filters AFA SI-20
SPC ldquoDozardquoRadiation monitoring equipment
74 75
Calibration of gamma dose and dose rate meters
Calibration ofbull Ambient equivalent dose H(10) meters (Sv Svh)bull Personal equivalent dose Hp(10) meters (Sv Svh)bull Exposure dose X meters (R Rh)bull Two sources in irradiator bull Select source and collimator opening using
tumbler
UPG-P DESKTOP GAMMA BEAM IRRADIATOR
Physical characteristicsRange of reproduced dose rate bull 05 μSvh divide 10 mSvh (50 μRh divide 100 mRh)
Sources activities bull 6times106 6times108 Bq (02 20 mCi) Cs-137
Overall dimensions bull 1250times400times300 mm
Irradiator weight bull Not more than 37 kg
Calibration bench weight bull Not more than 15 kg
Reference standards IEC 60846 IEC 61526
Physical characteristicsDetectorbull Silicon
Measurement range EEC measurement bull Measurement range of radon EEC
10 divide 10bull106 Bqbullm-3
bull Measurement range of thoron EEC 05 divide 10bull104 Bqbullm-3
bull Air flow through the filter 100plusmn05 lmin
Concentration measurementbull Measurement range of radon-222 concentration
in air 10 divide 20bull106 cpsbull Measurement range of 216Po(ThA)
1bull10-3 divide 1bull102 cpsbull Air sampler flow rate
10plusmn02 lminbull Measurement range of radon-222 concentration
in water samples 6 divide 800 Bqbullkg-1
bull Measurement range of radon-222 flux from soil surface 20 divide 103 mBqsbullm2
bull Measurement range of radon-222 concentration with preliminary sampling of air using air sam-plers 20 divide 107 Bqbullm-3
bull Measurement range of radon-222 concentration in samples of soil air 103 divide 106 Bqbullm-3
Operation temperature range bull 1 divide 35 ordmC
Electrical characteristicsPower supply bull 80 VA
Mechanical characteristicsOverall dimensions weight bull 220times200times165 mm 36 kg
ldquoALPHARAD PLUSrdquoRADON THORON amp THEIR PROGENY MONITORbull Measurement of radon and thoron concentration
and effective equivalent concentration (EEC)bull In the airbull In the indoor air of residential public and industri-
al buildings and structuresbull Measurement of radon in drinking water sourcesbull Measurements of radon flux from the soil surface
at land plots allocated for construction of houses public buildings and industrial facilities
bull Measurements of radon concentration in soil air
Reference standards IEC 61577
SPC ldquoDozardquoRadiation monitoring equipment
76 77
UKPN-2M-D NEUTRON BEAM IRRADIATOR
Reference standards IEC 61005 61322
Calibration of neutron dose and dose rate meters
Calibration ofbull Ambient equivalent dose H(10) meters (Sv Svh)bull Personal equivalent dose Hp(10) meters (Sv Svh)bull Flux density of neutrons (cm-2∙s-1)bull Transfer container for temporary storage of
sources bull Red light signal of source working position
Physical carachteristicsRange of reproduced dose ratebull 20 divide 800 μSvh
Range of reproduced flux densitiesbull 10 divide 400 cm-2∙s-1
Type of a source in use bull Pu-Be
Activity of a source in usebull 24х1011 Bq (with density of 107 s-1)
Overall dimensions weight no morebull 3000x750x2000 mm 300 kg
Required room dimensionsbull not less than 7x3x3 m
Electrical characteristicsPower supply bull 220 V 50 Hz
Calibration of gamma dose and dose rate meters
Calibration ofbull Ambient equivalent dose H(10) meters (Sv Svh)bull Personal equivalent dose Hp(10) meters (Sv Svh)bull Exposure dose X meters (R Rh)bull Four sources in irradiator bull Select source and move to working position
return to storage position using special rodbull Transfer container for temporary storage of
sources bull Red light signal of source working position
UPGD-2M-DGAMMA BEAM IRRADIATOR
Physical characteristicsRange of reproduced dose rate bull 05 μSvh divide 50 mSvh (50 μRh divide 5 Rh)
Maximum activity of source bull 2times1011 Bq (50 Ci) Cs-137
Overall dimensionsbull Irradiator 800times500times500 mmbull Guide rails length 30 mbull Height 16 mbull Weight not more than 700 kgbull Required room dimensions not less than 7x3x3 m
Electrical characteristicsPower supply bull 220 V 50 Hz
UPGD-2M-D
Reference standards IEC 60846 IEC 61526 IEC 61066
SPC ldquoDozardquo
78 79
Contents
MEASURING UNITS
DBG-S11D wide range gamma area monitor 40
UDKS-100 gamma and X-ray area monitor 41
UDMN-100 neutron area monitor 41
ALARM UNITS
BAS-2 ldquoMICROrdquo external visual alarm 42
BZS-2 ldquoMicrordquo external audible alarm 42
Illuminated warning signs 43
ldquoImpulsrdquo external display unit 43
UIM-3D area monitor count rate meter 44
DKG-05D personal gamma dosimeter 46
DVS-02D gamma-neutron personal electronic dosimeter 47
DVGI-8D new pen-type personal ionization chamber dosimeters 48
DKG-02U ldquoARBITERrdquo wide range gamma-dosimeter 49
DKG-07D ldquoDROZDrdquo gamma-dosimeter 50
MKS-15D ldquoSNEGIRrdquo multi ndash purpose radiation survey meter 51
SRPS-05D gamma monitor 52
DOZA-TLD multipurpose TLD system 53
DKS-96 universal radiation survey meter 54
EXTERNAL PROBES ALPHA
Alpha BDZA-96 55
Alpha BDZA-96B 55
Alpha BDZA-96M 55
Alpha BDZA-96S 55
Alpha BDZA-96T 55
EXTERNAL PROBES BETA
Beta BDZB-96 56
Beta BDZB-99 56
Beta BDZB-96B 56
Beta BDZB-96S 56
EXTERNAL PROBES GAMMA
Gamma BDKS-96B 57
Gamma and beta BDKS-96S 57
Gamma BDMG-96 57
EXTERNAL PROBES GAMMA
Gamma-search BDVG-96 58
Gamma-search BDPG-96 58
ContentsRadiation monitoring systemldquoPELIKANrdquo Radiation monitoring system (RMS) 6
BDMG-101 high range gamma area monitor 10
DBG-S11D wide range gamma area monitor 11
BDRG-52 high range gamma area monitor for accident and post-accident conditions 12
UDGP-01 Liquid technological environments monitor 13
UDMN-100 neutron area monitor 14
UDKG-100 Wel Liquid gamma monitor 14
BOP-1M data processing and transmission unit 15
UDA-1AB particulate monitor 16
UDG-1B noble gas monitor 17
UDG-03D noble gas monitor 18
UDI-1B iodine monitor 19
UDGB-01 noble gasesH-3C-14 monitor 20
UDGP-01 steam generator leakage monitor 21
UPPVM air flow parameters monitor 22
ldquoIMPULSrdquo external display unit 23
BI-2 remote display amp alarm unit 24
BASBAS-1s external alarm 25
SKGAV stack monitor 26
RMS software 28
RMS workstation ndash operator console 29
Configurator software 29
RM RACK radiation monitoring rack 30
SRKS-01D criticality accident alarm system 32
ldquoATLANT-Mrdquo environmental radiation monitoring system 34
ldquoBREEZErdquo high-volume air sampler 35
ldquoGAMMA-SENSORrdquo gamma-survey system 36
Radiation monitoring equipmentAREA MONITOR ldquoFREGATrdquo 38
BPI-1D local display unit 39
80
Gamma-search BDPG-96M 58
Gamma BDKG-96 stainless steel casing for geologic applications well logging 59
EXTERNAL PROBES NEUTRON
Neutron BDMN-96 59
Neutron-search BDKN-96 59
RZB-05D Hand-foot-clothing monitor 60
RZBA-04-04M whole body contamination monitor 61
RZA-05D alpha hand-monitor 62
UMF-2000 low level alpha- beta- counter 63
DRK dose area product meter 64
ldquoPROGRESS-BETArdquo scintillation beta spectrometer 65
ldquoPROGRESS-GAMMArdquo scintillation gamma spectrometer 66
ldquoPROGRESS-G(P)rdquo portable scintillation gamma spectrometer 67
ldquoPROGRESS-ARrdquo alpha radiometer 68
ldquoPROGRESSrdquo whole body counter 69
MKG-01D ldquoSADOVNIKrdquo spectrometry system 70
MKS-01A ldquoMULTIRAD-ASrdquo alpha spectrometer 71
UCRV-2 airflow monitor 72
PVP-06 portable air sampler 73
ldquoALPHARAD PLUSrdquo radon thoron amp their progeny monitor 74
UPG-P desktop gamma beam irradiator 75
UPGD-2M-D gamma beam irradiator 76
UKPN-2M-D neutron beam irradiator 77
SPC ldquoDozardquoRadiation monitoring equipment
4342
ALARM UNITS
Generation visual signals of the excess of preset thresholds
Physical characteristicsLength of communication cablebull up to 1200 mbull Alarm Visual alarm green yellow red
Electrical characteristicsbull Power supply +12 V
Mechanical characteristicsbull Protection index IP 23
Overall dimensions weight 160times84times41 mm 02 kg
BAS-2 ldquoMICROrdquo EXTERNAL VISUAL ALARM
Generation audible signals of the excess of preset thresholds
Physical characteristicsLength of communication cablebull up to 1200 mbull Audible alarm 80 divide 100 dB at a distance of 1 m
Electrical characteristicsbull Power supply +12 V
Mechanical characteristicsbull Protection index IP 23
Overall dimensions weight 160times84times41 mm 02 kg
BZS-2 ldquoMICROrdquo EXTERNAL AUDIBLE ALARM
Physical characteristicsLength of communication cablebull up to 1200 m
Electrical characteristicsbull Power supply 220 V 50 Hz
Mechanical characteristicsbull Protection index IP 23
Overall dimensions weight bull 330times110times20 mm 05 kg
Physical characteristicsLength of communication cablebull up to 1200 m
Character height bull ldquoImpuls-910-Rrdquo 100 mmbull ldquoImpuls-915-D4Srdquo 150 mmbull ldquoImpuls-927-D4Srdquo 270 mm
Operating temperature rangebull ldquoImpuls-910-Rrdquo 0 divide +50 degCbull ldquoImpuls-915-D4Srdquo ldquo-727-D4Srdquo minus 40 divide +50 degC
Electrical characteristicsbull Power supply 220 V 50 Hz
Mechanical characteristicsProtection index bull ldquoImpuls-910-R IP 44bull ldquoImpuls-915-D4Srdquo ldquo-727-D4Srdquo IP 65
Overall dimensions weight bull ldquoImpuls-910-Rrdquo 400times160times60 mm 3 kgbull ldquoImpuls-915-D4Srdquo 815times250times80 mm 5 kgbull ldquoImpuls-927-D4Srdquo 1250times330times80 mm 5 kg
ILLUMINATED WARNING SIGNS
ldquoIMPULSrdquo EXTERNAL DISPLAY UNIT
SPC ldquoDozardquoRadiation monitoring equipment
4544
Individual threshold setting for each measurement channel
Continuous area and process monitoring
Collect amp display data from two measurement chan-nels (units with RS-485 or analog pulses)
Audible and visual alarms on exceeding preset thresholds or status of connected devices
Individual threshold setting for each measurement channel
Switching on the external alarm or executive devices when any threshold is exceeded
The wide panel displays the following information bull Values of measured parameters as min-1∙cm-2
s-1∙cm-2 μSvhbull Diagnostic information about the status of con-
nected devicesbull Current date and timebull Position of measured values with respect to the
thresholds in the form of scales with green yellow and red zones
bull Time history (trend) for each measured value
Physical characteristics Measurement range bull Count rate up to 107 CPM (170 kHz)
Operating temperature range bull minus 20 divide +50 ordmC
Electrical characteristics bull Power supply 220 V bull Interfaces USB
Mechanical characteristics bull Protection index IP 65 bull Overall dimensions weight 222times164times73 mm
40 kg
UIM-3D AREA MONITOR COUNT RATE METER
Measurement of alpha radiation flux density
Detector unit BDZA-100 (70 cm2) Measurement range 01 divide 104 min-1∙cm-2
Detector unit BDZA-100B (300 cm2) Measurement range 01 divide 2103 min-1∙cm-2
Measurement of beta radiation flux density
Detector unit BDZB-100 (28 cm2) Measurement range 10 divide 105 min-1∙cm-2
Detector unit BDZB-100L (30 cm2) Measurement range 10 divide 104 min-1∙cm-2
Detector unit BDZB-11D (84 cm2) Measurement range 5 divide 15∙104 min-1∙m-2
OPTIONAL PROBESMeasurement of gamma radiation flux density
Detector units BDEG-03 Measurement range 4 divide 2000 s-1∙cm-2
Detector unit UDKG-100 for operation in the rocks ore liquid media and sludge Measurement range 40 divide 8000 s-1∙cm-2
Measurement of the ambient dose equivalent rate
Detector unit DBG-S11D Measurement range 01 μSvh divide 100 Svh
Measurement of neutron radiation ambient dose equivalent rate
Detector unit BDMN-100 Measurement range 01 μSvh divide 01 Svh
SPC ldquoDozardquoRadiation monitoring equipment
46 47Reference standards Nuclear IEC 61526
Measurement of gamma-radiation personal dose equivalent Hp(10)bull Stand-alone dosimeter or composed of dosimetric
system onebull Audible and visual alarmbull Large memory dose accumulation historiesbull Exclusion of unauthorized intervention in dosim-
etry operation
DKG-05D PERSONAL GAMMA DOSIMETER
Physical characteristicsDetectors bull Silicon
Measurement range bull Dose rate 1 μSvh divide 10 Svhbull Dose 01 μSv divide 15 Sv
Energy range bull 005 divide 30 MeV
Electrical characteristicsbull Power supply rechargeable NiMH battery 1
alcaline battery (type AAA)
Operation timebull Till recharging not less 400 hoursbull With one set batteries not less 1000 hours
Mechanical characteristicsOverall dimensions weight bull 47times26times87 mm (with clip) 70 g
Environmental characteristicsbull IP65bull Temperature range minus 20 divide +45 ordmCbull Humidity up to 98 at 35 ordmCbull Shock vibration and drop resistant
Alarmbull Excess of alarm thresholdsbull Warnings of self-test failure and battery discharge bull Audible alarm 80 dB at 40 cmbull Visual alarm blinking LED
Relative equipmentbull One dosimeter charger ZU-1Mbull Chargestorage cassetes KZU-28KZU-56bull ldquoSmart chargingrdquo feature extends battery life timebull DKG-05D reader US-05bull DKG-05D system reader DVS-01D
Reader-PC interfacebull US-05 USB bull DVS-01D Ethernet
KZU-28
Physical characteristicsDetectors bull Silicon Li-6
Gamma measurement range bull Dose rate 1 μSvh divide 10 Svhbull Dose 01 μSv divide 15 Sv
Gamma energy range bull 005 divide 60 MeV
Neutron measurement range bull Dose rate 1 μSvh divide 2 Svhbull Dose 20 μSv divide 15 Sv
Neutron energy range bull 0025 eV divide 20 MeV
Electrical characteristicsPower supply bull Rechargeable NiMH batterybull Operatiion time till recharging not less 200 hours
Mechanical characteristicsOverall dimensions weight bull 47times26times87 mm (with clip) 70 g
Environmental characteristicsbull IP65bull Temperature range minus 20 divide +40 ordmCbull Humidity up to 75 at 30 ordmCbull Shock vibration and drop resistant
Alarmbull Excess of alarm thresholds bull Warnings of self-test failure and battery discharge bull Audible alarm 80 dB at 40 cmbull Visual alarm blinking LED
Relative equipmentbull One dosimeter charger ZU-1Mbull Chargestorage cassetes KZU-28 KZU-56bull ldquoSmart chargingrdquo feature extends battery life timebull DVS-02D reader UZS-01Sbull DVS-02D system reader DVS-01D
Reader-PC interfacebull UZS-01S USB bull DVS-01D Ethernet
UZS-01DReference standards Nuclear IEC 61526
DVS-02D GAMMA-NEUTRON PERSONAL ELECTRONIC DOSIMETER
Measurement of gamma- and neutron radiations personal dose equivalent Hp(10)bull Stand-alone dosimeter or composed of dosimetric
system onebull Audible and visual alarmbull Large memory dose accumulation historiesbull Exclusion of unauthorized intervention in dosim-
etry operationbull Both albedo thermal neutrons and intermediate
fast neutrons registrationbull Usable in the fields of Pu(Be) Po(Be) Cf and other
neutron sources as well as near nuclear reactors without neutron spectrum estimation
SPC ldquoDozardquoRadiation monitoring equipment
48 49
Dosimeters DVG-03D
DVGI-8D NEW PEN-TYPE PERSONAL IONIZATION CHAMBER DOSIMETERS
Measurement of personal dose equivalent Hp(10) of gamma and X-ray radiationbull Hp(10) of continuous and pulsed gamma and
X-ray radiation bull Electronic reader KSU-1bull Dosimeter DVG-03D with electronic ID bull Personal dose histories in the readerrsquos memorybull Readerrsquos connection with PC for database main-
tenance
Physical characteristicsDetector bull Ionization chamber
Measurement range bull 001 mSv divide 25 mSv
Energy range bull 0015 divide 25 MeV
Temperature range bull Reader KSU-1 +10 divide +50 ordmСbull Dosimeter DVG-03D minus 40 divide +50 ordmС
Electrical characteristicsPower supply bull Reader KSU-1 220 V 50 Hz built-in batteries bull Dosimeter DVG-03D four batteries CR 1025 bull Batteries life 3 yearsbull Readers interfaces RS-232USB 20
Mechanical characteristicsOverall dimensions weightbull Dosimeter DVG-03D Oslash 18times126 mm 005 kgbull Reader KSU-1 235times232times125 mm 28 kg
Reference standards Nuclear IEC 62387-1
DKG-02U ldquoARBITERrdquo WIDE RANGE GAMMA-DOSIMETER
Physical characteristicsDetectors bull GM counters
Measurement rangebull Dose-rate 01 μSvh divide 3 Svhbull Dose 1 μSv divide 100 Sv
Energy range bull 005 divide 3 MeV
Electrical characteristicsbull Power supply 2 alcaline batteries (type AA)bull Batteries life not less 200 hours
Mechanical characteristicsOverall dimensions weight bull 152times82times32 mm 03 kg
Environmental characteristicsbull Temperature range minus 20 divide +50 ordmCbull Humidity up to 90 at +25 ordmCbull Shock vibration and drop resistant
Reference standards Nuclear IEC 60846
Measurement of gamma radiation ambient equiva-lent dose H(10) and dose rate H(10)bull Audible signals (clicks) for radiation condition
estimationbull Analog scale for search modebull Audible and visual alarms of the excess of preset
dose and dose rate thresholds bull Shock-resistant water-proof easy decontamina-
tion casebull 100 measurement results memory with date and
time of measurementbull Indication of total dose accumulated during
exploitation time bull Indication of measurement result statistical
uncertainty
SPC ldquoDozardquoRadiation monitoring equipment
50 51
Physical characteristicsDetectors bull GM counter
Measurement rangebull Dose-rate 01 μSvh divide 3 mSvhbull Dose 1 μSv divide 02 Sv
Energy range bull 005 divide 3 MeV
Temperature range bull Minus 20 divide +50 ordmC
Electrical characteristicsbull Power supply 2 alcaline batteries 15 V (type AA)bull Batteries life not less 200 hours
Mechanical characteristicsOverall dimensions weight bull 122times74times29 mm 025 kg
Reference standards Nuclear IEC 60846
DKG-07D ldquoDROZDrdquoGAMMA-DOSIMETER
Measurement of gamma radiation ambient equiva-lent dose H(10) and dose rate H(10)bull Two independent measurement channels dose
and dose ratebull Audible signals (clicks) for radiation condition
estimationbull Continuous measurement with updating meas-
urement resultbull Measurement result can be obtained with any
desired statistical uncertainty (error)bull Automatic restart when radiation level sharply
changesbull Indication of statistical uncertainty (error) during
measurement process
Continuous measurement with updating measure-ment result
Automatic restart when radiation level sharply changes bull Gamma dose H(10) and dose-rate H(10) meas-
urementbull Beta and gamma contamination surveybull Indication of statistical uncertainty during the
measurementbull Continuous measurement with accuracy increas-
ing with time bull Automatic restart triggered by change of gamma
dose-ratebull Compensation of gamma count rate while meas-
uring beta radiationbull Indication of battery charge levelbull Audible signal of the excess of preset threshold
Physical characteristicsDetectors bull GM counter
Measurement range bull Dose-rate 01 microSvh divide 20 mSvhbull Dose 1 microSv divide 100 Svbull Beta flux density (for Sr-90+Y-90)
10 divide 105 cm-2 min-1
Energy range bull Gamma 005 divide 3 MeVbull Beta 01 divide 3 MeV
Temperature range bull Minus 20 divide +50 ordmC
MKS-15D ldquoSnegirrdquo backside
MKS-15D ldquoSNEGIRrdquoMULTI ndash PURPOSE RADIATION SURVEY METER
Reference standards Nuclear IEC 60846 IEC 60325
Electrical characteristicsbull Power supply 2 alcaline batteries (type AA)bull Battery life not less 400 hours
Mechanical characteristicsOverall dimensions weight bull 124times72times35 mm 035 kg
SPC ldquoDozardquoRadiation monitoring equipment
52 53
Physical characteristicsDetectorbull GM counter
Measurement range bull 01 μSvh divide 20 mSvh
Energy range bull 005 divide 30 MeV
Threshold setting range bull 03 μSvh divide 20 mSvh
Step change of the thresholdbull In the range 03 divide 10 μSvh with the step
001 μSvhbull In the range 10 divide 100 μSvh with the step
01 μSvhbull In the range 100 divide 2000 μSvh with the step
10 μSvh
Electrical characteristicsPower supply bull 220 V 50 Hz bull Relay output
Mechanical characteristicsProtection index bull IP 40
Overall dimensions weight bull 226times120times75 mm 07 kg
Alarmbull Sound alarm 80 divide 100 dBA at distance 1 mbull Visual alarm redbull Connection of the external alarm signaling unit
Reference standards Nuclear IEC 60846 IEC 60532
Continuous automatic monitoring of the ambient dose equivalent rate bull Measurement of gamma dose rate H(10)bull Audible and visual alarm signals for preset
thresholdsbull Switching on the external signaling or executive
devices
SRPS-05D GAMMA MONITOR
Measurement ofbull Gamma and X-ray personal dose equivalent
Hp(10)bull Neutron personal dose equivalent Hp(10)bull Lens dose equivalent Hp(3)bull Skin dose equivalent Hp(007)bull TLD reader day-to-day tests using built-in LEDbull No needs nitrogen for heating
Physical charachteristicsDetectors bull 7LiF Mg Ti (gamma beta)bull 6LiF Mg Ti (neutron)
Gamma and X-ray Hp(10) Measurement range bull 500 μSv divide 10 Sv
Energy range bull 0015 divide 30 MeV
Neutron Hp(10)Measurement range bull 01 mSv divide 100 mSv
Energy range bull 0025 eV divide 10 MeV
Beta and photons Hp(007) Hp(3) Measurement range bull 2 mSv divide 100 Sv
Energy range bull Beta 025 divide 35 MeVbull Photons lt15 keV
Mechanical characteristicsDosimeters overall dimensions weight bull Gamma Hp(10) DTL-2 holder - 62times26times16 mm
16 gbull DTU holder - 42times28times18 mm 8 gbull Lens Hp(3) face skin Hp(007) Oslash 32times16 mm 9 gbull Finger skin Hp(007) 90times20times2 mm 1 gbull Neutron gamma Hp(10) 48times40times20 mm 30 g
Reference standards Nuclear IEC 61066
DTL-2 DTU-2
MKD (A-type) DVNG-M
DOZA-TLD MULTIPURPOSE TLD SYSTEM
SPC ldquoDozardquoRadiation monitoring equipment
54 55
Continuous and pulsed gamma and X-ray dose H(10) and dose-rate measurementbull Alpha beta and gamma contamination surveybull Neutron dose H(10) and dose-rate measurementbull Gamma radiation flux density in boreholes and
liquid media measurement
Electrical characteristicsPower supply bull UIK-05 four C-size batteriesbull UIK-05-01 rechargeable batterybull UIK-06 rechargeable battery
Interfaces bull RS-232bull USB (via adapter)
bull Detector type automatic determination and corre-sponding measurement modes selection
bull Alarm threshold settings ndash for dose dose-rate alpha and beta contaminations
bull ldquoDetectrdquo and ldquoLocaterdquo modes for survey probes
Reference standards Nuclear IEC 60846 IEC 60325 IEC 61005 IEC 62363
Case
UIK-06 control unit165times78times48 mm 03 kg
DKS-96UNIVERSAL RADIATION SURVEY METER
UIK-05 control unit202times86times90 mm 10 kg
BDZA-96
BDZA-96B
BDZA-96M
BDZA-96S
BDZA-96T
EXTERNAL PROBES ALPHAALPHA BDZA-96Detector bull ZnS(Ag) 70 cm2
Measurement range (for Pu-239)bull 01 divide 104 min-1cm-2
Overall dimensions weightbull Oslash 130times240 mm 11 kg
ALPHA BDZA-96BDetector bull ZnS(Ag) 300 сm2
Measurement range (for Pu-239)bull 01 divide 2103 min-1cm-2
Overall dimensions weightbull Oslash 230times290 mm 40 kg
ALPHA BDZA-96MDetector bull ZnS(Ag) 10 сm2
Measurement range (for Pu-239)bull 01 divide 105 min-1cm-2
Overall dimensions weightbull Oslash 65times240 mm 09 kg
ALPHA BDZA-96SDetector bull ZnS(Ag) 30 сm2
Measurement range (for Pu-239)bull 01 divide 5104 min-1cm-2
Overall dimensions weightbull Oslash 90times240 mm 10 kg
ALPHA BDZA-96TDetector bull Silicon 5 сm2
Measurement range (for Pu-239)bull 01 divide 106 min-1cm-2
Overall dimensions weightbull Oslash 50times60 mm 015 kg
SPC ldquoDozardquoRadiation monitoring equipment
56 57
BETA BDZB-96Detector Scintillator 28 сm2
Measurement range (for Sr-90+Y-90)bull 10 divide 105 min-1cm-2
Energy rangebull 03 divide 30 MeV
Overall dimensions weightbull Oslash 90times230 mm 09 kg
BETA BDZB-99Detector bull GM counter 30 сm2
Measurement range (for Sr-90+Y-90)bull 20 divide 104 min-1см-2
Energy rangebull 012 divide 30 MeV
Overall dimensions weightbull Oslash 88times80 mm 04 kgbull Telescopic pole length 07 m
BETA BDZB-96BDetector bull GM counter 80 сm2
Measurement range (for Sr-90+Y-90)bull 3 divide 104 min-1сm-2
Energy rangebull 012 divide 30 MeV
Overall dimensions weightbull 150times200times110 mm 15 kg
BETA BDZB-96Sbull Detector GM counter 15 сm2
Measurement range (for Sr-90+Y-90)bull 10 divide 3104 min-1cm-2
Energy rangebull 012 divide 30 MeV
Overall dimensions weightbull Oslash 65times65 mm 03 kgbull Telescopic pole length 07 m
BDZB-96
BDZB-99
BDZB-96B
BDZB-96S
EXTERNAL PROBES BETA
GAMMA BDKS-96BDetector bull Tissue-equivalent scintillator Oslash 45times20 mm
Measurement rangebull Dose rate H(10) 01 μSvh divide 1 Svhbull Dose H(10) 01 μSv divide 10 Sv
Energy rangebull 0015 divide 10 MeV
Overall dimensions weightbull Oslash 60times250 mm 085 kg
GAMMA AND BETA BDKS-96SDetector bull Double GM counters
Measurement rangebull Gamma dose rate H(10) 01 μSvh divide 1 mSvhbull Gamma dose H(10) 01 μSv divide 10 Svbull Beta 10 divide 3104 min-1cm-2
Energy rangebull Gamma 005 divide 3 MeVbull Beta 012 divide 3 MeV
Overall dimensions weightbull Oslash 80times80 mm 035 kgbull Telescopic pole length 07 m
GAMMA BDMG-96Detector bull GM counters
Measurement rangebull Dose rate H(10) 01 μSvh divide 10 Svhbull Dose H(10) 01 μSv divide 10 Sv
Energy range bull 005 divide 3 MeV
Overall dimensions weightbull 40times250 mm 05 kgbull Telescopic pole length 07 m 4 m (by request)
EXTERNAL PROBES GAMMA
BDKS-96B
BDMG-96
BDKS-96S
SPC ldquoDozardquoRadiation monitoring equipment
58 59
GAMMA-SEARCH BDVG-96Detector bull Scintillator NaI(Tl) Oslash 63times63 mm
Measurement rangebull Flux density measurement range 4 divide 2000 s-1cm-2
bull Dose rate H(10) for Cs-137 01 divide 30 μSvhbull Sensitivity for Cs-137 3000 (pulsess-1)( μSvh-1)
Overall dimensions weightbull Oslash 88times400 mm 20 kgbull Modular pole length 16 m
GAMMA-SEARCH BDPG-96Detector bull Scintillator NaI(Tl) Oslash 25times40 mm
Measurement rangebull Flux density measurement range 10 divide 8000 s-1cm-2
bull Dose rate H(10) for Cs-137 01 divide 100 μSvhbull Sensitivity for Cs-137 500 (pulsess-1)( μSvh-1)
Overall dimensions weightbull 50times190times480 mm 10 kgbull Telescopic pole length 07 m
GAMMA-SEARCH BDPG-96MDetector bull Scintillator NaI(Tl) Oslash 18times30 mm
Measurement rangebull Flux density measurement range 10 divide 24000 s-1cm-2
bull Dose rate H(10) for Cs-137 01 divide 300 μSvhbull Sensitivity for Cs-137 200 (pulsess-1)( μSvh-1)
Overall dimensions weightbull Oslash 35times320 mm 05 kgbull Telescopic pole length 07 or 38 m
EXTERNAL PROBES GAMMA
BDVG-96
BDPG-96M
BDPG-96
EXTERNAL PROBESGAMMA BDKG-96 STAINLESS STEEL CASING FOR GEOLOGIC APPLICATIONS WELL LOGGINGDetector bull Scintillator NaI(Tl) Oslash 18times30 mm
Measurement rangebull Flux density measurement range 10 divide 105 s-1cm-2
bull Dose rate H(10) for Cs-137 5 divide 2104 μRhbull Sensitivity for Cs-137 200 (pulsess-1)( μSvh-1)
Overall dimensions weightbull Oslash 38times535 mm 36 kgbull Cable length 10 divide 1000 m
NEUTRON BDMN-96Detector bull Scintillator with ZnS(Ag)
Measurement rangebull Dose rate H(10) 01 μSvh divide 01 Svhbull Dose H(10) 01 μSv divide 10 Sv
Energy range bull 0025 eV divide 10 MeV
Overall dimensions weightbull Detector Oslash 54times200 mm 08 kgbull Moderator Oslash 245 mm 73 kg
NEUTRON-SEARCH BDKN-96Detector bull He-3 counter in polyethilene moderator
Measurement rangebull Dose rate H(10) for Pu-Be 01 μSvh divide 01 Svhbull Dose H(10) for Pu-Be 01 μSv divide 10 Sv
Energy range bull 0025 eV divide 14 MeV
Overall dimensions weightbull 295times142times100 mm 225 kg
BDKG-96M
BDMN-96
BDKN-96
SPC ldquoDozardquoRadiation monitoring equipment
60 61
bull No gas supply neededbull Clothing control detachable right hand detector bull Alpha detector optional connection bull Numeric and color (red green) indication of
control resultsbull LED sensor of hand-foot positioning for start of
measurementbull Automatic compensation of gamma background
and contamination of detectorbull Audible alarm signals of the excess of preset
thresholdsbull Measurement value indication min-1cm-2 or
Bqсm2
Reference standards Nuclear IEC 61098
RZB-05D HAND-FOOT-CLOTHING MONITOR
Physical characteristicsDetectors bull Gamma beta - GM countersbull Alpha - scintillatior ZnS(Ag)
Detecting nuclidesbull Alpha Pu-239 U-234 U-238bull Beta Sr-90+Y-90 F-18 Cs-137 Co-60 Tс-99 O-15
N-13 Sr-89 C-11 I-131 Na-22 Ru-106+Rh-106 Tl-204
bull Gamma Tc-99m I-123
Efficiencybull Alpha
Pu-239 40 U-234 25U-238 15
bull Beta Sr-90 +Y-90 40
Measurement range bull Alpha 1 divide 103 min-1cm-2 bull Beta 10 divide 103 min-1cm-2
bull Gamma 5103 divide 5106 min-1cm-2
Energy range bull Alpha 30 divide 80 MeV bull Beta 008 divide 35 MeV bull Gamma 005 divide 30 MeV
Operation temperature range bull Minus 10 divide +50 ordmС
Electrical characteristicsbull Power supply 220 V 50 Hz
Mechanical characteristicsOverall dimensions weight bull 740times750times1180 mm 45 kg
Versionsbull Withwithout alpha detectorbull Indication (min-1cm-2 ) or (Bqсm2)bull Detectors overall dimensions smbull Hand 178 х 235bull Foot 185 х 436
Whole body contamination monitor RZBA-04-04Mbull No gas supply neededbull Compensation for background gamma radiation
and contamination of detector unitsbull Individual threshold setting for each measure-
ment channelbull Visible and audible alarms ldquoCONTAMINATIONrdquo and
ldquoCLEANrdquo bull Indication of contaminated body parts on the
panel with image of the bodybull Optional remote alpha-detector
Physical characteristicsDetectors bull Beta - GM counters scintillatorsbull Alpha - scintillatior ZnS(Ag)
Measurement range bull Beta 5 divide 15000 min-1cm-2
bull Alpha 01 divide 10000 min-1cm-2
Energy range bull Beta 015 divide 25 MeV bull Alpha 40 divide 56 MeV
Operation temperature range bull +5 divide +50 ordmС
Electrical characteristicsPower supply bull 220 V 50 Hz
Interfaces bull RS-232bull RS-485
Mechanical characteristicsOverall dimensions weight bull 2650times940times930 mm 310 kg
Versionsbull Withwithout alpha detectorbull Indication (min-1cm-2 ) or (Bqсm2)
Reference standards Nuclear IEC 61098
RZBA-04-04MWHOLE BODY CONTAMINATION MONITOR
SPC ldquoDozardquoRadiation monitoring equipment
62 63
RZA-05DALPHA HAND-MONITOR
bull No gas supply needed bull Numeric and color (red green) indication of
control resultsbull LED sensor of hand- positioning for start of
measurementbull Audible alarm signals of the excess of preset
thresholdsbull Measurement value indication min-1cm-2 or
Bqсm2
Physical characteristicsDetectors alpha - scintillatior ZnS(Ag)
Efficiencybull Pu-239 20 bull U-234 14bull U-238 8
Measurement range bull 05 divide 105 min-1cm-2
Energy range bull 41 divide 90 MeV
Operation temperature range bull minus 10 divide +50 ordmС
Electrical characteristicsPower supply bull 220 V 50 Hz
Mechanical characteristicsOverall dimensions weight no more bull 740times1400times1450 mm 70 kg
Reference standards Nuclear IEC 61098
bull Simultaneous measurement of alphabeta activi-ties in the sample
bull Active shielding anti-coincidence background subtraction using GM counters
bull Lead shielding 30 mm
UMF-2000 LOW LEVEL ALPHA- BETA- COUNTER
Physical characteristicsDetectors bull Silicon specrometric detector 500 or 1000 mm2
Measurement range bull Alpha 001 divide 1000 Bq bull Beta 01 divide 3000 Bq
Energy range bull Alpha 35 divide 80 MeV bull Beta 005 divide 35 MeV
Electrical characteristicsPower supply bull 220 V 50 Hz
Interfaces bull RS-232bull USB
Mechanical characteristicsOverall dimensions weight bull 337times286times190 mm 22 kg
Versionsbull Detector area 500 mm2
bull Detector area 1000 mm2
UMF-2000 Detector area 1000 mm2
UMF-2000 Detector area 500 mm2
SpectraDec software for alpha-spectrometric measurements
SPC ldquoDozardquoRadiation monitoring equipment
64 65
DRK DOSE AREA PRODUCT METER
DRK-1bull Diagnostic reference level (DRL) of patients
determinationbull Suitable for all basic types of x-ray machines
Physical characteristicsDetector bull Plane-parallel ionization chamber
Measurement range bull 1 divide 104 cGycm2
Electrical characteristicsPower supply bull 220 V 50 Hz
DRK-1M-CTbull Measuring of dose length product
Physical characteristicsDetector bull Pencil Ionization Chamber
Measurement rangebull 05 divide 109 microGym
DRK-1Mbull Measuring of air kerma on sectional area of the
X-ray beam productbull Measuring of air kerma rate on area productbull Measuring of air kerma ratebull Measuring of air kerma
Physical characteristicsDetector bull Plane-parallel ionization chamber
Measurement rangebull 01 divide 109 microGym2
bull 06 divide 6104 microGym2cbull 30 divide 9105 microGycbull 30 divide 9991011 microGyReference standard IEC 60580 2003
bull Measurement of strontium-90 in the foodstuffs agricultural products etc
bull Measurement of gross beta activity in samplebull Self tests using built-in LED
ldquoPROGRESS-BETArdquo SCINTILLATION BETA SPECTROMETER
Physical characteristicsDetector bull Plastic scintillator Oslash70x10 mm
Sample bull Plate Oslash70 mmbull Weight up to 15 g
Energy range bull 02 divide 30 MeV
Minimum detectable activity of Sr-90 in a 10 g sample on a standard planchet Bqsamplebull In case of absence of K-40 in the sample 01 Bqbull In case the activity of K-40 till 5 Bqg 05 Bq
Electrical characteristics Interface bull USB
Mechanical characteristicsWeight bull No more 50 kg
Complete setBasic complete setbull Detector unit with plastic scintillator integrated
power supply amplifier ADC bull Lead shielding bull ldquoProgressrdquo software bull Сheck source for energetic calibration (Sr-90-Y-90) bull Planchet Oslash 70 mm (5 items) bull Sample dencification device bull Procedure manual for measurement of radio-
nuclidesrsquo activity using the scintillation beta spec-trometer ldquoProgressrdquo
Optional equipment and servicebull Personal computer and printer bull Calibrations for radionuclides not included in the
main library of radionuclides
Progress-Beta
Reference standards IEC 61562
SPC ldquoDozardquoRadiation monitoring equipment
66 67
bull Measurement of gamma activity in foodstuffs soil samples and others environmental objects
bull Identification of radionuclides in the sample bull Automatic correction for sample density bull Self-tests using built-in LED
ldquoPROGRESS-GAMMArdquoSCINTILLATION GAMMA SPECTROMETER
Physical characteristicsDetector bull NaI (Tl) Oslash63times63 mm
Validated measurement geometries bull Marinelli beakers (1 liter) Petri dishes (Oslash90 mm)
etc
Energy range bull 02 divide 30 MeV
Minimum detectable activity Bqsamplebull Cs-137 3 Bqbull Th-232 7 Bqbull Ra-226 8 Bq bull К-40 40 Bq
Electrical characteristics Interface bull USB
Mechanical characteristicsWeight bull No more 120 kg
Complete setBasic complete setbull Scintillation detector unit with NaI (Tl) detector
with integrated power supply amplifier and ADC bull Lead shielding 50 mm bull ldquoProgressrdquo software bull Сheck source for energy calibration (Cs-137 +
K-40)bull Marinelli beakers - 1 liter (5 items) bull Petri dishes Oslash 90 mm (5 items) bull Procedure manual for measurement of activity
of radionuclides using the scintillation gamma spectrometer ldquoProgressrdquo
Optional equipment and servicebull Kit for radon measurements including calibration
of ldquoIC-63rdquo geometry for counting the charcoal samples
bull Personal computer and printer bull Calibrations for user defined geometries bull Calibrations for radionuclides not included in the
main library of radionuclides
Progress-Gamma
Reference standards IEC 61563
ldquoPROGRESS-G(P)rdquoPORTABLE SCINTILLATION GAMMA SPECTROMETERbull Field measurements of gamma activity in environ-
mental objects without sampling (4π geometry)bull Laboratory measurement of gamma activity in
foodstuffs soil samples and others environmental objects
bull Identification of radionuclides in the sample bull Automatic correction for sample densitybull Tests using built-in LED
Physical charachteristicsDetector bull NaI (Tl) Oslash45times50 mmbull Lead shielding 20 mm
Validated measurement geometries bull Marinelli beakers (05 liter) Petri dishes (Oslash90 mm)
etc
Energy range bull 02 divide 30 MeV
Minimum detectable activity in 05-litre Marinelli beaker bull Cs-13710 Bqkgbull К-40100 Bqkgbull Ra-22618 Bqkg bull Th-23216 Bqkg
Minimum detectable activity in 30 min (4π geometry) bull Cs-137 2 Bqkgbull К-40 30 Bqkgbull Ra-226 4 Bqkg bull Th-232 3 Bqkg
Electrical characteristicsPower supply bull Rechargeable batterybull 220 V 50 Hz
Interface bull USB RS-232
Weight bull No more than 60 kg
Complete setBasic complete setbull Scinttillation detector unit with NaI(Tl) bull ldquoProgressrdquo softwarebull Сontrol unit ldquoSputnikrdquo for aquisition and analisys
of spectra with built-in memory for spectral databull Casebull Lead shielding (2 cm) for laboratory usebull 05-litre Marinelli beakers ndash 5 itemsbull Na-22 check sourcebull Power adapter BPS-01bull Operation manualbull Procedure manual for measurement of activity
of radionuclides using the scintillation gamma spectrometer ldquoProgressrdquo
Optional equipment and servicebull Kit for radon measurements with charcoalbull Built-in dose rate meterbull Additional memory (RAM) for storage of 64
spectrabull Additional power adapterbull Notebook and printer
Progress-Gamma
Reference standards IEC 61563
SPC ldquoDozardquoRadiation monitoring equipment
68 69
Physical characteristicsDetectorbull Scintillation detector ZnS (Oslash 60 mm)
Samplebull Thin sample - diameter up to 70 mm bull Preparation technique - electro-depositionbull Thick sample - diameter 70 mm weight
200300 mg bull Preparation technique - application of powders
(prepared by radiochemical concentration by water evaporation or by pounding of mineral samples) onto a planchet with the help of spirit
Energy rangebull 15 divide 8 MeV
Minimum detectable activitybull Thin samples no more than 910-3 Bqsamplebull Thick samples no more than 180 Bqkg
Mechanical characteristicsOverall dimensions weightbull 195times120times210 mm 34 kg
Complete setBasic complete setbull Alpha radiometer ldquoProgress-ARrdquobull Check source (uranium isotopes)
Set of accessoriesbull Procedure manual for measurements of radi-
oactivity using scintillation alpha radiometer ldquoProgress-ARrdquo
bull ldquoProgressrdquo software
ldquoProgress-ARrdquo
bull Measurement of gross activity of alpha emitting radionuclides in thin samples
bull Measurement of gross activity of alpha emitting radionuclides in thick samples
bull Measurement of activity deposited on aerosol filters
ldquoPROGRESS-ARrdquoALPHA RADIOMETER
Several fixed positions of the detector enable to perform measurements in various geometries and to estimate the content ofbull Cs-137 in the whole bodybull I-131 in thyroidbull Co-60 Cs-137 Mn-54 Cr-51 in lungsbull Database for storage of measurement data and
resultsbull Uncertainty calculations based on measurement
databull Self tests using built-in LED
ldquoPROGRESSrdquo WHOLE BODY COUNTER
Physical characteristicsDetectorbull scintillation detector NaI (Tl) Oslash63times63 mm
Energy rangebull 02 divide 28 MeV
Minimum detectable activitybull By Cs-137 in the whole body - 1200 Bqbull By I-131 in thyroid - 100 Bqbull By Co-60 Cs-137 Mn-54 Cr-51 in lungs - 200 Bq
Mechanical characteristicsWeight bull No more than 120 kg
Complete setBasic complete setbull Collimator with rotator and holderbull Detector with incorporated ADCbull Patient chair and table for collimatorbull Check source Na-22bull Procedure manual for lifetime measurement of
gamma-emitting radionuclidesrsquo activity in human body using the gamma-spectrometer of human radiation ldquoProgressrdquo
bull laquoProgressraquo software
Optional equipment and servicebull Program of internal radiation committed internal
radiation effective dose calculation by the stand-ard model
bull Background phantombull Personal computer and printer
Collimator with rotator and holder
SPC ldquoDozardquoRadiation monitoring equipment
70 71
bull Categorization of wastes for the purpose of fur-ther processing including wastes with unknown radionuclide composition
bull Measurements during the incoming waste inspec-tion (accepting for storage disposal)
bull Certification of unconditioned and conditioned wastes in closed containers without opening them (at nuclear plants or at facilities providing collection storage transportation conditioning processing temporal storage and final disposal of radioactive waste)
bull Activity measurement of extended objects in situ without opening the equipment
bull Activity measurement of extended objects after opening (for example assessment of tubes used for oil transportation)
MKG-01D ldquoSADOVNIKrdquoSPECTROMETRY SYSTEM
Physical charachteristicsDetectorbull Detector unit GEM (GMX) with HPGe detector and
multi-positioning cryostat CFG-PMOD4-7 with 7 litre Dewar
bull Dose rate probe BDMG-200
Energy range bull With GEM detector 004 divide 30 MeVbull With GMX detector 0005 divide 15 MeVbull Dose rate probe BDMG-200 ndash 005 divide 30 MeV
Measurement rangebull 110-7 divide 10 Svhbull Relative efficiency of detection (in photopeak) at
13325 MeV (Co-60) 10 divide 150
Electrical characteristicsPower supplybull 220 V 50 Hz
Interfacebull USB
Complete setBasic complete setbull Spectrometric detector unit GEM (GMX) with
HPGe detector and multi-positioning cryostat with 7 litre Dewar
bull Portable digital multichannel analyzer DigiDARTbull Dose rate probe BDMG-200bull Autonomous power supply unit with built-in
batterybull Industrial computer keyboardbull Laser range-finderbull Thermographic printerbull Web-camerabull Device equipped with stepper motor for position-
ing of the spectrometric detectorbull Calibration device with reference sources
(Am-241 Co-60 Ba-133 Eu-152) for energy calibration
bull Removable collimators with end capbull Measurement proceduresbull ldquoClasterrdquo software
bull Measurement of gross alpha activity of alpha-emitting radionuclides
bull Measurement of alpha-emitting radionuclides activity in thin-layer samples meeting alpha-spectrometry requirements
Physical characteristicsDetectorbull Silicon ion-implanted 450 mm2
bull Easy to decontaminate thin windowbull dead layer less than 015 μmbull Background count rate in the range 3 divide 9 MeVbull No more than 09 h-1cm-2 for 450 mm2 detector
Energy rangebull 2 divide 9 MeVbull Lower limit of measurement range (minimum
detectable activity) 01 Bqbull Background count rate no more than 100 counts
in 24 hours
Electrical characteristics Power supplybull 220 V 50 Hz
Interfacebull USB
Complete setBasic complete setbull Detector unit with vacuum measuring chamber
and vacuum control systembull Low noise vacuum pump (type 2FY-05B or
equivalent)bull Check sourcebull ldquoProgressrdquo softwarebull Vacuum tube
MKS-01A ldquoMULTIRAD-ASrdquoALPHA SPECTROMETER
SPC ldquoDozardquoRadiation monitoring equipment
72 73
UCRV-2AIRFLOW MONITOR
bull Monitor of the air flow through filter of centralized multichannel sampling system
bull Radiation monitoring system (RMS) integration for internal exposures determination
bull Volume and flow rate measurements of the air that have passed through a analytical filter
bull Bar-code for filter identificationbull Operation as either standalone unit or as a part of
the RMS
Physical characteristicsMeasurement range of air volume bull 001 divide 9999 m3
Operation temperature range bull minus 20 divide +50 ordmС
Electrical characteristicsPower supply bull 220 V 50 Hz
Interface bull RS-485
PVP-06PORTABLE AIR SAMPLER
Air Sampler PVP-06 is indispensable for monitoring the radiation situation where the concentration of radioactive aerosols in the air does not require a sta-tionary sampling equipment Sampling head PVP-06 provides easy change of filters and cartridges
Purposebull To monitor the concentration of radioactive aero-
sols in the air sites
Controlled aerosolsbull Alpha- and beta-active aerosolsbull Daughter products of decay of radon and thoronbull Iodine isotopes
Physical characteristicsTypes of filtersbull Aerosol AFA-RSP-20bull Iodine AFA SI-20
Flow rate bull 33∙10-4 ndash 233∙10-4 m3s (20 divide 140 l min)
Electrical characteristicsPower supply bull 220 V50 Hzbull The vehicle power supply 108 divide 145 Vbull Internal battery
Minimal working time on internal battery to recharge bull 8 hours
Power consumption (at a flow rate of 100 lmin) bull 40 VA
Environment characteristicsOperating temperature bull minus 10 divide +40 deg C
Maximum humidity bull 90
Pressure bull 860 to 1060 hPA
Noise generated by the pump bull lt 55 dBA at 1 m
Mechanical characteristicsDimensions weight bull 241 times 108 times 160 mm 28 kg
Case material bull Plastic
Complete setbull Air sampler PVP-06bull AC power adapterbull Filters AFA-RSP-20 - 100 pcsbull Packaging for filters - 40 pcsbull Casebull Operation manualbull Calibration certificate
Optional equimpient bull Kit for sampling sorption columns of activated
carbon Ř head of sorption columns with protective
covers Ř activated charcoal SKT-3 - 1 pkg (02 L) Ř charocoal samples SC-13 - 8 pcs
bull Car charger bull Tipod bull Shoulder strapbull Calibration stand bull Filters AFA SI-20 - 100 pcs
Consumablesbull Aerosol filters AFA RSP-20bull Iodine filters AFA SI-20
SPC ldquoDozardquoRadiation monitoring equipment
74 75
Calibration of gamma dose and dose rate meters
Calibration ofbull Ambient equivalent dose H(10) meters (Sv Svh)bull Personal equivalent dose Hp(10) meters (Sv Svh)bull Exposure dose X meters (R Rh)bull Two sources in irradiator bull Select source and collimator opening using
tumbler
UPG-P DESKTOP GAMMA BEAM IRRADIATOR
Physical characteristicsRange of reproduced dose rate bull 05 μSvh divide 10 mSvh (50 μRh divide 100 mRh)
Sources activities bull 6times106 6times108 Bq (02 20 mCi) Cs-137
Overall dimensions bull 1250times400times300 mm
Irradiator weight bull Not more than 37 kg
Calibration bench weight bull Not more than 15 kg
Reference standards IEC 60846 IEC 61526
Physical characteristicsDetectorbull Silicon
Measurement range EEC measurement bull Measurement range of radon EEC
10 divide 10bull106 Bqbullm-3
bull Measurement range of thoron EEC 05 divide 10bull104 Bqbullm-3
bull Air flow through the filter 100plusmn05 lmin
Concentration measurementbull Measurement range of radon-222 concentration
in air 10 divide 20bull106 cpsbull Measurement range of 216Po(ThA)
1bull10-3 divide 1bull102 cpsbull Air sampler flow rate
10plusmn02 lminbull Measurement range of radon-222 concentration
in water samples 6 divide 800 Bqbullkg-1
bull Measurement range of radon-222 flux from soil surface 20 divide 103 mBqsbullm2
bull Measurement range of radon-222 concentration with preliminary sampling of air using air sam-plers 20 divide 107 Bqbullm-3
bull Measurement range of radon-222 concentration in samples of soil air 103 divide 106 Bqbullm-3
Operation temperature range bull 1 divide 35 ordmC
Electrical characteristicsPower supply bull 80 VA
Mechanical characteristicsOverall dimensions weight bull 220times200times165 mm 36 kg
ldquoALPHARAD PLUSrdquoRADON THORON amp THEIR PROGENY MONITORbull Measurement of radon and thoron concentration
and effective equivalent concentration (EEC)bull In the airbull In the indoor air of residential public and industri-
al buildings and structuresbull Measurement of radon in drinking water sourcesbull Measurements of radon flux from the soil surface
at land plots allocated for construction of houses public buildings and industrial facilities
bull Measurements of radon concentration in soil air
Reference standards IEC 61577
SPC ldquoDozardquoRadiation monitoring equipment
76 77
UKPN-2M-D NEUTRON BEAM IRRADIATOR
Reference standards IEC 61005 61322
Calibration of neutron dose and dose rate meters
Calibration ofbull Ambient equivalent dose H(10) meters (Sv Svh)bull Personal equivalent dose Hp(10) meters (Sv Svh)bull Flux density of neutrons (cm-2∙s-1)bull Transfer container for temporary storage of
sources bull Red light signal of source working position
Physical carachteristicsRange of reproduced dose ratebull 20 divide 800 μSvh
Range of reproduced flux densitiesbull 10 divide 400 cm-2∙s-1
Type of a source in use bull Pu-Be
Activity of a source in usebull 24х1011 Bq (with density of 107 s-1)
Overall dimensions weight no morebull 3000x750x2000 mm 300 kg
Required room dimensionsbull not less than 7x3x3 m
Electrical characteristicsPower supply bull 220 V 50 Hz
Calibration of gamma dose and dose rate meters
Calibration ofbull Ambient equivalent dose H(10) meters (Sv Svh)bull Personal equivalent dose Hp(10) meters (Sv Svh)bull Exposure dose X meters (R Rh)bull Four sources in irradiator bull Select source and move to working position
return to storage position using special rodbull Transfer container for temporary storage of
sources bull Red light signal of source working position
UPGD-2M-DGAMMA BEAM IRRADIATOR
Physical characteristicsRange of reproduced dose rate bull 05 μSvh divide 50 mSvh (50 μRh divide 5 Rh)
Maximum activity of source bull 2times1011 Bq (50 Ci) Cs-137
Overall dimensionsbull Irradiator 800times500times500 mmbull Guide rails length 30 mbull Height 16 mbull Weight not more than 700 kgbull Required room dimensions not less than 7x3x3 m
Electrical characteristicsPower supply bull 220 V 50 Hz
UPGD-2M-D
Reference standards IEC 60846 IEC 61526 IEC 61066
SPC ldquoDozardquo
78 79
Contents
MEASURING UNITS
DBG-S11D wide range gamma area monitor 40
UDKS-100 gamma and X-ray area monitor 41
UDMN-100 neutron area monitor 41
ALARM UNITS
BAS-2 ldquoMICROrdquo external visual alarm 42
BZS-2 ldquoMicrordquo external audible alarm 42
Illuminated warning signs 43
ldquoImpulsrdquo external display unit 43
UIM-3D area monitor count rate meter 44
DKG-05D personal gamma dosimeter 46
DVS-02D gamma-neutron personal electronic dosimeter 47
DVGI-8D new pen-type personal ionization chamber dosimeters 48
DKG-02U ldquoARBITERrdquo wide range gamma-dosimeter 49
DKG-07D ldquoDROZDrdquo gamma-dosimeter 50
MKS-15D ldquoSNEGIRrdquo multi ndash purpose radiation survey meter 51
SRPS-05D gamma monitor 52
DOZA-TLD multipurpose TLD system 53
DKS-96 universal radiation survey meter 54
EXTERNAL PROBES ALPHA
Alpha BDZA-96 55
Alpha BDZA-96B 55
Alpha BDZA-96M 55
Alpha BDZA-96S 55
Alpha BDZA-96T 55
EXTERNAL PROBES BETA
Beta BDZB-96 56
Beta BDZB-99 56
Beta BDZB-96B 56
Beta BDZB-96S 56
EXTERNAL PROBES GAMMA
Gamma BDKS-96B 57
Gamma and beta BDKS-96S 57
Gamma BDMG-96 57
EXTERNAL PROBES GAMMA
Gamma-search BDVG-96 58
Gamma-search BDPG-96 58
ContentsRadiation monitoring systemldquoPELIKANrdquo Radiation monitoring system (RMS) 6
BDMG-101 high range gamma area monitor 10
DBG-S11D wide range gamma area monitor 11
BDRG-52 high range gamma area monitor for accident and post-accident conditions 12
UDGP-01 Liquid technological environments monitor 13
UDMN-100 neutron area monitor 14
UDKG-100 Wel Liquid gamma monitor 14
BOP-1M data processing and transmission unit 15
UDA-1AB particulate monitor 16
UDG-1B noble gas monitor 17
UDG-03D noble gas monitor 18
UDI-1B iodine monitor 19
UDGB-01 noble gasesH-3C-14 monitor 20
UDGP-01 steam generator leakage monitor 21
UPPVM air flow parameters monitor 22
ldquoIMPULSrdquo external display unit 23
BI-2 remote display amp alarm unit 24
BASBAS-1s external alarm 25
SKGAV stack monitor 26
RMS software 28
RMS workstation ndash operator console 29
Configurator software 29
RM RACK radiation monitoring rack 30
SRKS-01D criticality accident alarm system 32
ldquoATLANT-Mrdquo environmental radiation monitoring system 34
ldquoBREEZErdquo high-volume air sampler 35
ldquoGAMMA-SENSORrdquo gamma-survey system 36
Radiation monitoring equipmentAREA MONITOR ldquoFREGATrdquo 38
BPI-1D local display unit 39
80
Gamma-search BDPG-96M 58
Gamma BDKG-96 stainless steel casing for geologic applications well logging 59
EXTERNAL PROBES NEUTRON
Neutron BDMN-96 59
Neutron-search BDKN-96 59
RZB-05D Hand-foot-clothing monitor 60
RZBA-04-04M whole body contamination monitor 61
RZA-05D alpha hand-monitor 62
UMF-2000 low level alpha- beta- counter 63
DRK dose area product meter 64
ldquoPROGRESS-BETArdquo scintillation beta spectrometer 65
ldquoPROGRESS-GAMMArdquo scintillation gamma spectrometer 66
ldquoPROGRESS-G(P)rdquo portable scintillation gamma spectrometer 67
ldquoPROGRESS-ARrdquo alpha radiometer 68
ldquoPROGRESSrdquo whole body counter 69
MKG-01D ldquoSADOVNIKrdquo spectrometry system 70
MKS-01A ldquoMULTIRAD-ASrdquo alpha spectrometer 71
UCRV-2 airflow monitor 72
PVP-06 portable air sampler 73
ldquoALPHARAD PLUSrdquo radon thoron amp their progeny monitor 74
UPG-P desktop gamma beam irradiator 75
UPGD-2M-D gamma beam irradiator 76
UKPN-2M-D neutron beam irradiator 77
SPC ldquoDozardquoRadiation monitoring equipment
4544
Individual threshold setting for each measurement channel
Continuous area and process monitoring
Collect amp display data from two measurement chan-nels (units with RS-485 or analog pulses)
Audible and visual alarms on exceeding preset thresholds or status of connected devices
Individual threshold setting for each measurement channel
Switching on the external alarm or executive devices when any threshold is exceeded
The wide panel displays the following information bull Values of measured parameters as min-1∙cm-2
s-1∙cm-2 μSvhbull Diagnostic information about the status of con-
nected devicesbull Current date and timebull Position of measured values with respect to the
thresholds in the form of scales with green yellow and red zones
bull Time history (trend) for each measured value
Physical characteristics Measurement range bull Count rate up to 107 CPM (170 kHz)
Operating temperature range bull minus 20 divide +50 ordmC
Electrical characteristics bull Power supply 220 V bull Interfaces USB
Mechanical characteristics bull Protection index IP 65 bull Overall dimensions weight 222times164times73 mm
40 kg
UIM-3D AREA MONITOR COUNT RATE METER
Measurement of alpha radiation flux density
Detector unit BDZA-100 (70 cm2) Measurement range 01 divide 104 min-1∙cm-2
Detector unit BDZA-100B (300 cm2) Measurement range 01 divide 2103 min-1∙cm-2
Measurement of beta radiation flux density
Detector unit BDZB-100 (28 cm2) Measurement range 10 divide 105 min-1∙cm-2
Detector unit BDZB-100L (30 cm2) Measurement range 10 divide 104 min-1∙cm-2
Detector unit BDZB-11D (84 cm2) Measurement range 5 divide 15∙104 min-1∙m-2
OPTIONAL PROBESMeasurement of gamma radiation flux density
Detector units BDEG-03 Measurement range 4 divide 2000 s-1∙cm-2
Detector unit UDKG-100 for operation in the rocks ore liquid media and sludge Measurement range 40 divide 8000 s-1∙cm-2
Measurement of the ambient dose equivalent rate
Detector unit DBG-S11D Measurement range 01 μSvh divide 100 Svh
Measurement of neutron radiation ambient dose equivalent rate
Detector unit BDMN-100 Measurement range 01 μSvh divide 01 Svh
SPC ldquoDozardquoRadiation monitoring equipment
46 47Reference standards Nuclear IEC 61526
Measurement of gamma-radiation personal dose equivalent Hp(10)bull Stand-alone dosimeter or composed of dosimetric
system onebull Audible and visual alarmbull Large memory dose accumulation historiesbull Exclusion of unauthorized intervention in dosim-
etry operation
DKG-05D PERSONAL GAMMA DOSIMETER
Physical characteristicsDetectors bull Silicon
Measurement range bull Dose rate 1 μSvh divide 10 Svhbull Dose 01 μSv divide 15 Sv
Energy range bull 005 divide 30 MeV
Electrical characteristicsbull Power supply rechargeable NiMH battery 1
alcaline battery (type AAA)
Operation timebull Till recharging not less 400 hoursbull With one set batteries not less 1000 hours
Mechanical characteristicsOverall dimensions weight bull 47times26times87 mm (with clip) 70 g
Environmental characteristicsbull IP65bull Temperature range minus 20 divide +45 ordmCbull Humidity up to 98 at 35 ordmCbull Shock vibration and drop resistant
Alarmbull Excess of alarm thresholdsbull Warnings of self-test failure and battery discharge bull Audible alarm 80 dB at 40 cmbull Visual alarm blinking LED
Relative equipmentbull One dosimeter charger ZU-1Mbull Chargestorage cassetes KZU-28KZU-56bull ldquoSmart chargingrdquo feature extends battery life timebull DKG-05D reader US-05bull DKG-05D system reader DVS-01D
Reader-PC interfacebull US-05 USB bull DVS-01D Ethernet
KZU-28
Physical characteristicsDetectors bull Silicon Li-6
Gamma measurement range bull Dose rate 1 μSvh divide 10 Svhbull Dose 01 μSv divide 15 Sv
Gamma energy range bull 005 divide 60 MeV
Neutron measurement range bull Dose rate 1 μSvh divide 2 Svhbull Dose 20 μSv divide 15 Sv
Neutron energy range bull 0025 eV divide 20 MeV
Electrical characteristicsPower supply bull Rechargeable NiMH batterybull Operatiion time till recharging not less 200 hours
Mechanical characteristicsOverall dimensions weight bull 47times26times87 mm (with clip) 70 g
Environmental characteristicsbull IP65bull Temperature range minus 20 divide +40 ordmCbull Humidity up to 75 at 30 ordmCbull Shock vibration and drop resistant
Alarmbull Excess of alarm thresholds bull Warnings of self-test failure and battery discharge bull Audible alarm 80 dB at 40 cmbull Visual alarm blinking LED
Relative equipmentbull One dosimeter charger ZU-1Mbull Chargestorage cassetes KZU-28 KZU-56bull ldquoSmart chargingrdquo feature extends battery life timebull DVS-02D reader UZS-01Sbull DVS-02D system reader DVS-01D
Reader-PC interfacebull UZS-01S USB bull DVS-01D Ethernet
UZS-01DReference standards Nuclear IEC 61526
DVS-02D GAMMA-NEUTRON PERSONAL ELECTRONIC DOSIMETER
Measurement of gamma- and neutron radiations personal dose equivalent Hp(10)bull Stand-alone dosimeter or composed of dosimetric
system onebull Audible and visual alarmbull Large memory dose accumulation historiesbull Exclusion of unauthorized intervention in dosim-
etry operationbull Both albedo thermal neutrons and intermediate
fast neutrons registrationbull Usable in the fields of Pu(Be) Po(Be) Cf and other
neutron sources as well as near nuclear reactors without neutron spectrum estimation
SPC ldquoDozardquoRadiation monitoring equipment
48 49
Dosimeters DVG-03D
DVGI-8D NEW PEN-TYPE PERSONAL IONIZATION CHAMBER DOSIMETERS
Measurement of personal dose equivalent Hp(10) of gamma and X-ray radiationbull Hp(10) of continuous and pulsed gamma and
X-ray radiation bull Electronic reader KSU-1bull Dosimeter DVG-03D with electronic ID bull Personal dose histories in the readerrsquos memorybull Readerrsquos connection with PC for database main-
tenance
Physical characteristicsDetector bull Ionization chamber
Measurement range bull 001 mSv divide 25 mSv
Energy range bull 0015 divide 25 MeV
Temperature range bull Reader KSU-1 +10 divide +50 ordmСbull Dosimeter DVG-03D minus 40 divide +50 ordmС
Electrical characteristicsPower supply bull Reader KSU-1 220 V 50 Hz built-in batteries bull Dosimeter DVG-03D four batteries CR 1025 bull Batteries life 3 yearsbull Readers interfaces RS-232USB 20
Mechanical characteristicsOverall dimensions weightbull Dosimeter DVG-03D Oslash 18times126 mm 005 kgbull Reader KSU-1 235times232times125 mm 28 kg
Reference standards Nuclear IEC 62387-1
DKG-02U ldquoARBITERrdquo WIDE RANGE GAMMA-DOSIMETER
Physical characteristicsDetectors bull GM counters
Measurement rangebull Dose-rate 01 μSvh divide 3 Svhbull Dose 1 μSv divide 100 Sv
Energy range bull 005 divide 3 MeV
Electrical characteristicsbull Power supply 2 alcaline batteries (type AA)bull Batteries life not less 200 hours
Mechanical characteristicsOverall dimensions weight bull 152times82times32 mm 03 kg
Environmental characteristicsbull Temperature range minus 20 divide +50 ordmCbull Humidity up to 90 at +25 ordmCbull Shock vibration and drop resistant
Reference standards Nuclear IEC 60846
Measurement of gamma radiation ambient equiva-lent dose H(10) and dose rate H(10)bull Audible signals (clicks) for radiation condition
estimationbull Analog scale for search modebull Audible and visual alarms of the excess of preset
dose and dose rate thresholds bull Shock-resistant water-proof easy decontamina-
tion casebull 100 measurement results memory with date and
time of measurementbull Indication of total dose accumulated during
exploitation time bull Indication of measurement result statistical
uncertainty
SPC ldquoDozardquoRadiation monitoring equipment
50 51
Physical characteristicsDetectors bull GM counter
Measurement rangebull Dose-rate 01 μSvh divide 3 mSvhbull Dose 1 μSv divide 02 Sv
Energy range bull 005 divide 3 MeV
Temperature range bull Minus 20 divide +50 ordmC
Electrical characteristicsbull Power supply 2 alcaline batteries 15 V (type AA)bull Batteries life not less 200 hours
Mechanical characteristicsOverall dimensions weight bull 122times74times29 mm 025 kg
Reference standards Nuclear IEC 60846
DKG-07D ldquoDROZDrdquoGAMMA-DOSIMETER
Measurement of gamma radiation ambient equiva-lent dose H(10) and dose rate H(10)bull Two independent measurement channels dose
and dose ratebull Audible signals (clicks) for radiation condition
estimationbull Continuous measurement with updating meas-
urement resultbull Measurement result can be obtained with any
desired statistical uncertainty (error)bull Automatic restart when radiation level sharply
changesbull Indication of statistical uncertainty (error) during
measurement process
Continuous measurement with updating measure-ment result
Automatic restart when radiation level sharply changes bull Gamma dose H(10) and dose-rate H(10) meas-
urementbull Beta and gamma contamination surveybull Indication of statistical uncertainty during the
measurementbull Continuous measurement with accuracy increas-
ing with time bull Automatic restart triggered by change of gamma
dose-ratebull Compensation of gamma count rate while meas-
uring beta radiationbull Indication of battery charge levelbull Audible signal of the excess of preset threshold
Physical characteristicsDetectors bull GM counter
Measurement range bull Dose-rate 01 microSvh divide 20 mSvhbull Dose 1 microSv divide 100 Svbull Beta flux density (for Sr-90+Y-90)
10 divide 105 cm-2 min-1
Energy range bull Gamma 005 divide 3 MeVbull Beta 01 divide 3 MeV
Temperature range bull Minus 20 divide +50 ordmC
MKS-15D ldquoSnegirrdquo backside
MKS-15D ldquoSNEGIRrdquoMULTI ndash PURPOSE RADIATION SURVEY METER
Reference standards Nuclear IEC 60846 IEC 60325
Electrical characteristicsbull Power supply 2 alcaline batteries (type AA)bull Battery life not less 400 hours
Mechanical characteristicsOverall dimensions weight bull 124times72times35 mm 035 kg
SPC ldquoDozardquoRadiation monitoring equipment
52 53
Physical characteristicsDetectorbull GM counter
Measurement range bull 01 μSvh divide 20 mSvh
Energy range bull 005 divide 30 MeV
Threshold setting range bull 03 μSvh divide 20 mSvh
Step change of the thresholdbull In the range 03 divide 10 μSvh with the step
001 μSvhbull In the range 10 divide 100 μSvh with the step
01 μSvhbull In the range 100 divide 2000 μSvh with the step
10 μSvh
Electrical characteristicsPower supply bull 220 V 50 Hz bull Relay output
Mechanical characteristicsProtection index bull IP 40
Overall dimensions weight bull 226times120times75 mm 07 kg
Alarmbull Sound alarm 80 divide 100 dBA at distance 1 mbull Visual alarm redbull Connection of the external alarm signaling unit
Reference standards Nuclear IEC 60846 IEC 60532
Continuous automatic monitoring of the ambient dose equivalent rate bull Measurement of gamma dose rate H(10)bull Audible and visual alarm signals for preset
thresholdsbull Switching on the external signaling or executive
devices
SRPS-05D GAMMA MONITOR
Measurement ofbull Gamma and X-ray personal dose equivalent
Hp(10)bull Neutron personal dose equivalent Hp(10)bull Lens dose equivalent Hp(3)bull Skin dose equivalent Hp(007)bull TLD reader day-to-day tests using built-in LEDbull No needs nitrogen for heating
Physical charachteristicsDetectors bull 7LiF Mg Ti (gamma beta)bull 6LiF Mg Ti (neutron)
Gamma and X-ray Hp(10) Measurement range bull 500 μSv divide 10 Sv
Energy range bull 0015 divide 30 MeV
Neutron Hp(10)Measurement range bull 01 mSv divide 100 mSv
Energy range bull 0025 eV divide 10 MeV
Beta and photons Hp(007) Hp(3) Measurement range bull 2 mSv divide 100 Sv
Energy range bull Beta 025 divide 35 MeVbull Photons lt15 keV
Mechanical characteristicsDosimeters overall dimensions weight bull Gamma Hp(10) DTL-2 holder - 62times26times16 mm
16 gbull DTU holder - 42times28times18 mm 8 gbull Lens Hp(3) face skin Hp(007) Oslash 32times16 mm 9 gbull Finger skin Hp(007) 90times20times2 mm 1 gbull Neutron gamma Hp(10) 48times40times20 mm 30 g
Reference standards Nuclear IEC 61066
DTL-2 DTU-2
MKD (A-type) DVNG-M
DOZA-TLD MULTIPURPOSE TLD SYSTEM
SPC ldquoDozardquoRadiation monitoring equipment
54 55
Continuous and pulsed gamma and X-ray dose H(10) and dose-rate measurementbull Alpha beta and gamma contamination surveybull Neutron dose H(10) and dose-rate measurementbull Gamma radiation flux density in boreholes and
liquid media measurement
Electrical characteristicsPower supply bull UIK-05 four C-size batteriesbull UIK-05-01 rechargeable batterybull UIK-06 rechargeable battery
Interfaces bull RS-232bull USB (via adapter)
bull Detector type automatic determination and corre-sponding measurement modes selection
bull Alarm threshold settings ndash for dose dose-rate alpha and beta contaminations
bull ldquoDetectrdquo and ldquoLocaterdquo modes for survey probes
Reference standards Nuclear IEC 60846 IEC 60325 IEC 61005 IEC 62363
Case
UIK-06 control unit165times78times48 mm 03 kg
DKS-96UNIVERSAL RADIATION SURVEY METER
UIK-05 control unit202times86times90 mm 10 kg
BDZA-96
BDZA-96B
BDZA-96M
BDZA-96S
BDZA-96T
EXTERNAL PROBES ALPHAALPHA BDZA-96Detector bull ZnS(Ag) 70 cm2
Measurement range (for Pu-239)bull 01 divide 104 min-1cm-2
Overall dimensions weightbull Oslash 130times240 mm 11 kg
ALPHA BDZA-96BDetector bull ZnS(Ag) 300 сm2
Measurement range (for Pu-239)bull 01 divide 2103 min-1cm-2
Overall dimensions weightbull Oslash 230times290 mm 40 kg
ALPHA BDZA-96MDetector bull ZnS(Ag) 10 сm2
Measurement range (for Pu-239)bull 01 divide 105 min-1cm-2
Overall dimensions weightbull Oslash 65times240 mm 09 kg
ALPHA BDZA-96SDetector bull ZnS(Ag) 30 сm2
Measurement range (for Pu-239)bull 01 divide 5104 min-1cm-2
Overall dimensions weightbull Oslash 90times240 mm 10 kg
ALPHA BDZA-96TDetector bull Silicon 5 сm2
Measurement range (for Pu-239)bull 01 divide 106 min-1cm-2
Overall dimensions weightbull Oslash 50times60 mm 015 kg
SPC ldquoDozardquoRadiation monitoring equipment
56 57
BETA BDZB-96Detector Scintillator 28 сm2
Measurement range (for Sr-90+Y-90)bull 10 divide 105 min-1cm-2
Energy rangebull 03 divide 30 MeV
Overall dimensions weightbull Oslash 90times230 mm 09 kg
BETA BDZB-99Detector bull GM counter 30 сm2
Measurement range (for Sr-90+Y-90)bull 20 divide 104 min-1см-2
Energy rangebull 012 divide 30 MeV
Overall dimensions weightbull Oslash 88times80 mm 04 kgbull Telescopic pole length 07 m
BETA BDZB-96BDetector bull GM counter 80 сm2
Measurement range (for Sr-90+Y-90)bull 3 divide 104 min-1сm-2
Energy rangebull 012 divide 30 MeV
Overall dimensions weightbull 150times200times110 mm 15 kg
BETA BDZB-96Sbull Detector GM counter 15 сm2
Measurement range (for Sr-90+Y-90)bull 10 divide 3104 min-1cm-2
Energy rangebull 012 divide 30 MeV
Overall dimensions weightbull Oslash 65times65 mm 03 kgbull Telescopic pole length 07 m
BDZB-96
BDZB-99
BDZB-96B
BDZB-96S
EXTERNAL PROBES BETA
GAMMA BDKS-96BDetector bull Tissue-equivalent scintillator Oslash 45times20 mm
Measurement rangebull Dose rate H(10) 01 μSvh divide 1 Svhbull Dose H(10) 01 μSv divide 10 Sv
Energy rangebull 0015 divide 10 MeV
Overall dimensions weightbull Oslash 60times250 mm 085 kg
GAMMA AND BETA BDKS-96SDetector bull Double GM counters
Measurement rangebull Gamma dose rate H(10) 01 μSvh divide 1 mSvhbull Gamma dose H(10) 01 μSv divide 10 Svbull Beta 10 divide 3104 min-1cm-2
Energy rangebull Gamma 005 divide 3 MeVbull Beta 012 divide 3 MeV
Overall dimensions weightbull Oslash 80times80 mm 035 kgbull Telescopic pole length 07 m
GAMMA BDMG-96Detector bull GM counters
Measurement rangebull Dose rate H(10) 01 μSvh divide 10 Svhbull Dose H(10) 01 μSv divide 10 Sv
Energy range bull 005 divide 3 MeV
Overall dimensions weightbull 40times250 mm 05 kgbull Telescopic pole length 07 m 4 m (by request)
EXTERNAL PROBES GAMMA
BDKS-96B
BDMG-96
BDKS-96S
SPC ldquoDozardquoRadiation monitoring equipment
58 59
GAMMA-SEARCH BDVG-96Detector bull Scintillator NaI(Tl) Oslash 63times63 mm
Measurement rangebull Flux density measurement range 4 divide 2000 s-1cm-2
bull Dose rate H(10) for Cs-137 01 divide 30 μSvhbull Sensitivity for Cs-137 3000 (pulsess-1)( μSvh-1)
Overall dimensions weightbull Oslash 88times400 mm 20 kgbull Modular pole length 16 m
GAMMA-SEARCH BDPG-96Detector bull Scintillator NaI(Tl) Oslash 25times40 mm
Measurement rangebull Flux density measurement range 10 divide 8000 s-1cm-2
bull Dose rate H(10) for Cs-137 01 divide 100 μSvhbull Sensitivity for Cs-137 500 (pulsess-1)( μSvh-1)
Overall dimensions weightbull 50times190times480 mm 10 kgbull Telescopic pole length 07 m
GAMMA-SEARCH BDPG-96MDetector bull Scintillator NaI(Tl) Oslash 18times30 mm
Measurement rangebull Flux density measurement range 10 divide 24000 s-1cm-2
bull Dose rate H(10) for Cs-137 01 divide 300 μSvhbull Sensitivity for Cs-137 200 (pulsess-1)( μSvh-1)
Overall dimensions weightbull Oslash 35times320 mm 05 kgbull Telescopic pole length 07 or 38 m
EXTERNAL PROBES GAMMA
BDVG-96
BDPG-96M
BDPG-96
EXTERNAL PROBESGAMMA BDKG-96 STAINLESS STEEL CASING FOR GEOLOGIC APPLICATIONS WELL LOGGINGDetector bull Scintillator NaI(Tl) Oslash 18times30 mm
Measurement rangebull Flux density measurement range 10 divide 105 s-1cm-2
bull Dose rate H(10) for Cs-137 5 divide 2104 μRhbull Sensitivity for Cs-137 200 (pulsess-1)( μSvh-1)
Overall dimensions weightbull Oslash 38times535 mm 36 kgbull Cable length 10 divide 1000 m
NEUTRON BDMN-96Detector bull Scintillator with ZnS(Ag)
Measurement rangebull Dose rate H(10) 01 μSvh divide 01 Svhbull Dose H(10) 01 μSv divide 10 Sv
Energy range bull 0025 eV divide 10 MeV
Overall dimensions weightbull Detector Oslash 54times200 mm 08 kgbull Moderator Oslash 245 mm 73 kg
NEUTRON-SEARCH BDKN-96Detector bull He-3 counter in polyethilene moderator
Measurement rangebull Dose rate H(10) for Pu-Be 01 μSvh divide 01 Svhbull Dose H(10) for Pu-Be 01 μSv divide 10 Sv
Energy range bull 0025 eV divide 14 MeV
Overall dimensions weightbull 295times142times100 mm 225 kg
BDKG-96M
BDMN-96
BDKN-96
SPC ldquoDozardquoRadiation monitoring equipment
60 61
bull No gas supply neededbull Clothing control detachable right hand detector bull Alpha detector optional connection bull Numeric and color (red green) indication of
control resultsbull LED sensor of hand-foot positioning for start of
measurementbull Automatic compensation of gamma background
and contamination of detectorbull Audible alarm signals of the excess of preset
thresholdsbull Measurement value indication min-1cm-2 or
Bqсm2
Reference standards Nuclear IEC 61098
RZB-05D HAND-FOOT-CLOTHING MONITOR
Physical characteristicsDetectors bull Gamma beta - GM countersbull Alpha - scintillatior ZnS(Ag)
Detecting nuclidesbull Alpha Pu-239 U-234 U-238bull Beta Sr-90+Y-90 F-18 Cs-137 Co-60 Tс-99 O-15
N-13 Sr-89 C-11 I-131 Na-22 Ru-106+Rh-106 Tl-204
bull Gamma Tc-99m I-123
Efficiencybull Alpha
Pu-239 40 U-234 25U-238 15
bull Beta Sr-90 +Y-90 40
Measurement range bull Alpha 1 divide 103 min-1cm-2 bull Beta 10 divide 103 min-1cm-2
bull Gamma 5103 divide 5106 min-1cm-2
Energy range bull Alpha 30 divide 80 MeV bull Beta 008 divide 35 MeV bull Gamma 005 divide 30 MeV
Operation temperature range bull Minus 10 divide +50 ordmС
Electrical characteristicsbull Power supply 220 V 50 Hz
Mechanical characteristicsOverall dimensions weight bull 740times750times1180 mm 45 kg
Versionsbull Withwithout alpha detectorbull Indication (min-1cm-2 ) or (Bqсm2)bull Detectors overall dimensions smbull Hand 178 х 235bull Foot 185 х 436
Whole body contamination monitor RZBA-04-04Mbull No gas supply neededbull Compensation for background gamma radiation
and contamination of detector unitsbull Individual threshold setting for each measure-
ment channelbull Visible and audible alarms ldquoCONTAMINATIONrdquo and
ldquoCLEANrdquo bull Indication of contaminated body parts on the
panel with image of the bodybull Optional remote alpha-detector
Physical characteristicsDetectors bull Beta - GM counters scintillatorsbull Alpha - scintillatior ZnS(Ag)
Measurement range bull Beta 5 divide 15000 min-1cm-2
bull Alpha 01 divide 10000 min-1cm-2
Energy range bull Beta 015 divide 25 MeV bull Alpha 40 divide 56 MeV
Operation temperature range bull +5 divide +50 ordmС
Electrical characteristicsPower supply bull 220 V 50 Hz
Interfaces bull RS-232bull RS-485
Mechanical characteristicsOverall dimensions weight bull 2650times940times930 mm 310 kg
Versionsbull Withwithout alpha detectorbull Indication (min-1cm-2 ) or (Bqсm2)
Reference standards Nuclear IEC 61098
RZBA-04-04MWHOLE BODY CONTAMINATION MONITOR
SPC ldquoDozardquoRadiation monitoring equipment
62 63
RZA-05DALPHA HAND-MONITOR
bull No gas supply needed bull Numeric and color (red green) indication of
control resultsbull LED sensor of hand- positioning for start of
measurementbull Audible alarm signals of the excess of preset
thresholdsbull Measurement value indication min-1cm-2 or
Bqсm2
Physical characteristicsDetectors alpha - scintillatior ZnS(Ag)
Efficiencybull Pu-239 20 bull U-234 14bull U-238 8
Measurement range bull 05 divide 105 min-1cm-2
Energy range bull 41 divide 90 MeV
Operation temperature range bull minus 10 divide +50 ordmС
Electrical characteristicsPower supply bull 220 V 50 Hz
Mechanical characteristicsOverall dimensions weight no more bull 740times1400times1450 mm 70 kg
Reference standards Nuclear IEC 61098
bull Simultaneous measurement of alphabeta activi-ties in the sample
bull Active shielding anti-coincidence background subtraction using GM counters
bull Lead shielding 30 mm
UMF-2000 LOW LEVEL ALPHA- BETA- COUNTER
Physical characteristicsDetectors bull Silicon specrometric detector 500 or 1000 mm2
Measurement range bull Alpha 001 divide 1000 Bq bull Beta 01 divide 3000 Bq
Energy range bull Alpha 35 divide 80 MeV bull Beta 005 divide 35 MeV
Electrical characteristicsPower supply bull 220 V 50 Hz
Interfaces bull RS-232bull USB
Mechanical characteristicsOverall dimensions weight bull 337times286times190 mm 22 kg
Versionsbull Detector area 500 mm2
bull Detector area 1000 mm2
UMF-2000 Detector area 1000 mm2
UMF-2000 Detector area 500 mm2
SpectraDec software for alpha-spectrometric measurements
SPC ldquoDozardquoRadiation monitoring equipment
64 65
DRK DOSE AREA PRODUCT METER
DRK-1bull Diagnostic reference level (DRL) of patients
determinationbull Suitable for all basic types of x-ray machines
Physical characteristicsDetector bull Plane-parallel ionization chamber
Measurement range bull 1 divide 104 cGycm2
Electrical characteristicsPower supply bull 220 V 50 Hz
DRK-1M-CTbull Measuring of dose length product
Physical characteristicsDetector bull Pencil Ionization Chamber
Measurement rangebull 05 divide 109 microGym
DRK-1Mbull Measuring of air kerma on sectional area of the
X-ray beam productbull Measuring of air kerma rate on area productbull Measuring of air kerma ratebull Measuring of air kerma
Physical characteristicsDetector bull Plane-parallel ionization chamber
Measurement rangebull 01 divide 109 microGym2
bull 06 divide 6104 microGym2cbull 30 divide 9105 microGycbull 30 divide 9991011 microGyReference standard IEC 60580 2003
bull Measurement of strontium-90 in the foodstuffs agricultural products etc
bull Measurement of gross beta activity in samplebull Self tests using built-in LED
ldquoPROGRESS-BETArdquo SCINTILLATION BETA SPECTROMETER
Physical characteristicsDetector bull Plastic scintillator Oslash70x10 mm
Sample bull Plate Oslash70 mmbull Weight up to 15 g
Energy range bull 02 divide 30 MeV
Minimum detectable activity of Sr-90 in a 10 g sample on a standard planchet Bqsamplebull In case of absence of K-40 in the sample 01 Bqbull In case the activity of K-40 till 5 Bqg 05 Bq
Electrical characteristics Interface bull USB
Mechanical characteristicsWeight bull No more 50 kg
Complete setBasic complete setbull Detector unit with plastic scintillator integrated
power supply amplifier ADC bull Lead shielding bull ldquoProgressrdquo software bull Сheck source for energetic calibration (Sr-90-Y-90) bull Planchet Oslash 70 mm (5 items) bull Sample dencification device bull Procedure manual for measurement of radio-
nuclidesrsquo activity using the scintillation beta spec-trometer ldquoProgressrdquo
Optional equipment and servicebull Personal computer and printer bull Calibrations for radionuclides not included in the
main library of radionuclides
Progress-Beta
Reference standards IEC 61562
SPC ldquoDozardquoRadiation monitoring equipment
66 67
bull Measurement of gamma activity in foodstuffs soil samples and others environmental objects
bull Identification of radionuclides in the sample bull Automatic correction for sample density bull Self-tests using built-in LED
ldquoPROGRESS-GAMMArdquoSCINTILLATION GAMMA SPECTROMETER
Physical characteristicsDetector bull NaI (Tl) Oslash63times63 mm
Validated measurement geometries bull Marinelli beakers (1 liter) Petri dishes (Oslash90 mm)
etc
Energy range bull 02 divide 30 MeV
Minimum detectable activity Bqsamplebull Cs-137 3 Bqbull Th-232 7 Bqbull Ra-226 8 Bq bull К-40 40 Bq
Electrical characteristics Interface bull USB
Mechanical characteristicsWeight bull No more 120 kg
Complete setBasic complete setbull Scintillation detector unit with NaI (Tl) detector
with integrated power supply amplifier and ADC bull Lead shielding 50 mm bull ldquoProgressrdquo software bull Сheck source for energy calibration (Cs-137 +
K-40)bull Marinelli beakers - 1 liter (5 items) bull Petri dishes Oslash 90 mm (5 items) bull Procedure manual for measurement of activity
of radionuclides using the scintillation gamma spectrometer ldquoProgressrdquo
Optional equipment and servicebull Kit for radon measurements including calibration
of ldquoIC-63rdquo geometry for counting the charcoal samples
bull Personal computer and printer bull Calibrations for user defined geometries bull Calibrations for radionuclides not included in the
main library of radionuclides
Progress-Gamma
Reference standards IEC 61563
ldquoPROGRESS-G(P)rdquoPORTABLE SCINTILLATION GAMMA SPECTROMETERbull Field measurements of gamma activity in environ-
mental objects without sampling (4π geometry)bull Laboratory measurement of gamma activity in
foodstuffs soil samples and others environmental objects
bull Identification of radionuclides in the sample bull Automatic correction for sample densitybull Tests using built-in LED
Physical charachteristicsDetector bull NaI (Tl) Oslash45times50 mmbull Lead shielding 20 mm
Validated measurement geometries bull Marinelli beakers (05 liter) Petri dishes (Oslash90 mm)
etc
Energy range bull 02 divide 30 MeV
Minimum detectable activity in 05-litre Marinelli beaker bull Cs-13710 Bqkgbull К-40100 Bqkgbull Ra-22618 Bqkg bull Th-23216 Bqkg
Minimum detectable activity in 30 min (4π geometry) bull Cs-137 2 Bqkgbull К-40 30 Bqkgbull Ra-226 4 Bqkg bull Th-232 3 Bqkg
Electrical characteristicsPower supply bull Rechargeable batterybull 220 V 50 Hz
Interface bull USB RS-232
Weight bull No more than 60 kg
Complete setBasic complete setbull Scinttillation detector unit with NaI(Tl) bull ldquoProgressrdquo softwarebull Сontrol unit ldquoSputnikrdquo for aquisition and analisys
of spectra with built-in memory for spectral databull Casebull Lead shielding (2 cm) for laboratory usebull 05-litre Marinelli beakers ndash 5 itemsbull Na-22 check sourcebull Power adapter BPS-01bull Operation manualbull Procedure manual for measurement of activity
of radionuclides using the scintillation gamma spectrometer ldquoProgressrdquo
Optional equipment and servicebull Kit for radon measurements with charcoalbull Built-in dose rate meterbull Additional memory (RAM) for storage of 64
spectrabull Additional power adapterbull Notebook and printer
Progress-Gamma
Reference standards IEC 61563
SPC ldquoDozardquoRadiation monitoring equipment
68 69
Physical characteristicsDetectorbull Scintillation detector ZnS (Oslash 60 mm)
Samplebull Thin sample - diameter up to 70 mm bull Preparation technique - electro-depositionbull Thick sample - diameter 70 mm weight
200300 mg bull Preparation technique - application of powders
(prepared by radiochemical concentration by water evaporation or by pounding of mineral samples) onto a planchet with the help of spirit
Energy rangebull 15 divide 8 MeV
Minimum detectable activitybull Thin samples no more than 910-3 Bqsamplebull Thick samples no more than 180 Bqkg
Mechanical characteristicsOverall dimensions weightbull 195times120times210 mm 34 kg
Complete setBasic complete setbull Alpha radiometer ldquoProgress-ARrdquobull Check source (uranium isotopes)
Set of accessoriesbull Procedure manual for measurements of radi-
oactivity using scintillation alpha radiometer ldquoProgress-ARrdquo
bull ldquoProgressrdquo software
ldquoProgress-ARrdquo
bull Measurement of gross activity of alpha emitting radionuclides in thin samples
bull Measurement of gross activity of alpha emitting radionuclides in thick samples
bull Measurement of activity deposited on aerosol filters
ldquoPROGRESS-ARrdquoALPHA RADIOMETER
Several fixed positions of the detector enable to perform measurements in various geometries and to estimate the content ofbull Cs-137 in the whole bodybull I-131 in thyroidbull Co-60 Cs-137 Mn-54 Cr-51 in lungsbull Database for storage of measurement data and
resultsbull Uncertainty calculations based on measurement
databull Self tests using built-in LED
ldquoPROGRESSrdquo WHOLE BODY COUNTER
Physical characteristicsDetectorbull scintillation detector NaI (Tl) Oslash63times63 mm
Energy rangebull 02 divide 28 MeV
Minimum detectable activitybull By Cs-137 in the whole body - 1200 Bqbull By I-131 in thyroid - 100 Bqbull By Co-60 Cs-137 Mn-54 Cr-51 in lungs - 200 Bq
Mechanical characteristicsWeight bull No more than 120 kg
Complete setBasic complete setbull Collimator with rotator and holderbull Detector with incorporated ADCbull Patient chair and table for collimatorbull Check source Na-22bull Procedure manual for lifetime measurement of
gamma-emitting radionuclidesrsquo activity in human body using the gamma-spectrometer of human radiation ldquoProgressrdquo
bull laquoProgressraquo software
Optional equipment and servicebull Program of internal radiation committed internal
radiation effective dose calculation by the stand-ard model
bull Background phantombull Personal computer and printer
Collimator with rotator and holder
SPC ldquoDozardquoRadiation monitoring equipment
70 71
bull Categorization of wastes for the purpose of fur-ther processing including wastes with unknown radionuclide composition
bull Measurements during the incoming waste inspec-tion (accepting for storage disposal)
bull Certification of unconditioned and conditioned wastes in closed containers without opening them (at nuclear plants or at facilities providing collection storage transportation conditioning processing temporal storage and final disposal of radioactive waste)
bull Activity measurement of extended objects in situ without opening the equipment
bull Activity measurement of extended objects after opening (for example assessment of tubes used for oil transportation)
MKG-01D ldquoSADOVNIKrdquoSPECTROMETRY SYSTEM
Physical charachteristicsDetectorbull Detector unit GEM (GMX) with HPGe detector and
multi-positioning cryostat CFG-PMOD4-7 with 7 litre Dewar
bull Dose rate probe BDMG-200
Energy range bull With GEM detector 004 divide 30 MeVbull With GMX detector 0005 divide 15 MeVbull Dose rate probe BDMG-200 ndash 005 divide 30 MeV
Measurement rangebull 110-7 divide 10 Svhbull Relative efficiency of detection (in photopeak) at
13325 MeV (Co-60) 10 divide 150
Electrical characteristicsPower supplybull 220 V 50 Hz
Interfacebull USB
Complete setBasic complete setbull Spectrometric detector unit GEM (GMX) with
HPGe detector and multi-positioning cryostat with 7 litre Dewar
bull Portable digital multichannel analyzer DigiDARTbull Dose rate probe BDMG-200bull Autonomous power supply unit with built-in
batterybull Industrial computer keyboardbull Laser range-finderbull Thermographic printerbull Web-camerabull Device equipped with stepper motor for position-
ing of the spectrometric detectorbull Calibration device with reference sources
(Am-241 Co-60 Ba-133 Eu-152) for energy calibration
bull Removable collimators with end capbull Measurement proceduresbull ldquoClasterrdquo software
bull Measurement of gross alpha activity of alpha-emitting radionuclides
bull Measurement of alpha-emitting radionuclides activity in thin-layer samples meeting alpha-spectrometry requirements
Physical characteristicsDetectorbull Silicon ion-implanted 450 mm2
bull Easy to decontaminate thin windowbull dead layer less than 015 μmbull Background count rate in the range 3 divide 9 MeVbull No more than 09 h-1cm-2 for 450 mm2 detector
Energy rangebull 2 divide 9 MeVbull Lower limit of measurement range (minimum
detectable activity) 01 Bqbull Background count rate no more than 100 counts
in 24 hours
Electrical characteristics Power supplybull 220 V 50 Hz
Interfacebull USB
Complete setBasic complete setbull Detector unit with vacuum measuring chamber
and vacuum control systembull Low noise vacuum pump (type 2FY-05B or
equivalent)bull Check sourcebull ldquoProgressrdquo softwarebull Vacuum tube
MKS-01A ldquoMULTIRAD-ASrdquoALPHA SPECTROMETER
SPC ldquoDozardquoRadiation monitoring equipment
72 73
UCRV-2AIRFLOW MONITOR
bull Monitor of the air flow through filter of centralized multichannel sampling system
bull Radiation monitoring system (RMS) integration for internal exposures determination
bull Volume and flow rate measurements of the air that have passed through a analytical filter
bull Bar-code for filter identificationbull Operation as either standalone unit or as a part of
the RMS
Physical characteristicsMeasurement range of air volume bull 001 divide 9999 m3
Operation temperature range bull minus 20 divide +50 ordmС
Electrical characteristicsPower supply bull 220 V 50 Hz
Interface bull RS-485
PVP-06PORTABLE AIR SAMPLER
Air Sampler PVP-06 is indispensable for monitoring the radiation situation where the concentration of radioactive aerosols in the air does not require a sta-tionary sampling equipment Sampling head PVP-06 provides easy change of filters and cartridges
Purposebull To monitor the concentration of radioactive aero-
sols in the air sites
Controlled aerosolsbull Alpha- and beta-active aerosolsbull Daughter products of decay of radon and thoronbull Iodine isotopes
Physical characteristicsTypes of filtersbull Aerosol AFA-RSP-20bull Iodine AFA SI-20
Flow rate bull 33∙10-4 ndash 233∙10-4 m3s (20 divide 140 l min)
Electrical characteristicsPower supply bull 220 V50 Hzbull The vehicle power supply 108 divide 145 Vbull Internal battery
Minimal working time on internal battery to recharge bull 8 hours
Power consumption (at a flow rate of 100 lmin) bull 40 VA
Environment characteristicsOperating temperature bull minus 10 divide +40 deg C
Maximum humidity bull 90
Pressure bull 860 to 1060 hPA
Noise generated by the pump bull lt 55 dBA at 1 m
Mechanical characteristicsDimensions weight bull 241 times 108 times 160 mm 28 kg
Case material bull Plastic
Complete setbull Air sampler PVP-06bull AC power adapterbull Filters AFA-RSP-20 - 100 pcsbull Packaging for filters - 40 pcsbull Casebull Operation manualbull Calibration certificate
Optional equimpient bull Kit for sampling sorption columns of activated
carbon Ř head of sorption columns with protective
covers Ř activated charcoal SKT-3 - 1 pkg (02 L) Ř charocoal samples SC-13 - 8 pcs
bull Car charger bull Tipod bull Shoulder strapbull Calibration stand bull Filters AFA SI-20 - 100 pcs
Consumablesbull Aerosol filters AFA RSP-20bull Iodine filters AFA SI-20
SPC ldquoDozardquoRadiation monitoring equipment
74 75
Calibration of gamma dose and dose rate meters
Calibration ofbull Ambient equivalent dose H(10) meters (Sv Svh)bull Personal equivalent dose Hp(10) meters (Sv Svh)bull Exposure dose X meters (R Rh)bull Two sources in irradiator bull Select source and collimator opening using
tumbler
UPG-P DESKTOP GAMMA BEAM IRRADIATOR
Physical characteristicsRange of reproduced dose rate bull 05 μSvh divide 10 mSvh (50 μRh divide 100 mRh)
Sources activities bull 6times106 6times108 Bq (02 20 mCi) Cs-137
Overall dimensions bull 1250times400times300 mm
Irradiator weight bull Not more than 37 kg
Calibration bench weight bull Not more than 15 kg
Reference standards IEC 60846 IEC 61526
Physical characteristicsDetectorbull Silicon
Measurement range EEC measurement bull Measurement range of radon EEC
10 divide 10bull106 Bqbullm-3
bull Measurement range of thoron EEC 05 divide 10bull104 Bqbullm-3
bull Air flow through the filter 100plusmn05 lmin
Concentration measurementbull Measurement range of radon-222 concentration
in air 10 divide 20bull106 cpsbull Measurement range of 216Po(ThA)
1bull10-3 divide 1bull102 cpsbull Air sampler flow rate
10plusmn02 lminbull Measurement range of radon-222 concentration
in water samples 6 divide 800 Bqbullkg-1
bull Measurement range of radon-222 flux from soil surface 20 divide 103 mBqsbullm2
bull Measurement range of radon-222 concentration with preliminary sampling of air using air sam-plers 20 divide 107 Bqbullm-3
bull Measurement range of radon-222 concentration in samples of soil air 103 divide 106 Bqbullm-3
Operation temperature range bull 1 divide 35 ordmC
Electrical characteristicsPower supply bull 80 VA
Mechanical characteristicsOverall dimensions weight bull 220times200times165 mm 36 kg
ldquoALPHARAD PLUSrdquoRADON THORON amp THEIR PROGENY MONITORbull Measurement of radon and thoron concentration
and effective equivalent concentration (EEC)bull In the airbull In the indoor air of residential public and industri-
al buildings and structuresbull Measurement of radon in drinking water sourcesbull Measurements of radon flux from the soil surface
at land plots allocated for construction of houses public buildings and industrial facilities
bull Measurements of radon concentration in soil air
Reference standards IEC 61577
SPC ldquoDozardquoRadiation monitoring equipment
76 77
UKPN-2M-D NEUTRON BEAM IRRADIATOR
Reference standards IEC 61005 61322
Calibration of neutron dose and dose rate meters
Calibration ofbull Ambient equivalent dose H(10) meters (Sv Svh)bull Personal equivalent dose Hp(10) meters (Sv Svh)bull Flux density of neutrons (cm-2∙s-1)bull Transfer container for temporary storage of
sources bull Red light signal of source working position
Physical carachteristicsRange of reproduced dose ratebull 20 divide 800 μSvh
Range of reproduced flux densitiesbull 10 divide 400 cm-2∙s-1
Type of a source in use bull Pu-Be
Activity of a source in usebull 24х1011 Bq (with density of 107 s-1)
Overall dimensions weight no morebull 3000x750x2000 mm 300 kg
Required room dimensionsbull not less than 7x3x3 m
Electrical characteristicsPower supply bull 220 V 50 Hz
Calibration of gamma dose and dose rate meters
Calibration ofbull Ambient equivalent dose H(10) meters (Sv Svh)bull Personal equivalent dose Hp(10) meters (Sv Svh)bull Exposure dose X meters (R Rh)bull Four sources in irradiator bull Select source and move to working position
return to storage position using special rodbull Transfer container for temporary storage of
sources bull Red light signal of source working position
UPGD-2M-DGAMMA BEAM IRRADIATOR
Physical characteristicsRange of reproduced dose rate bull 05 μSvh divide 50 mSvh (50 μRh divide 5 Rh)
Maximum activity of source bull 2times1011 Bq (50 Ci) Cs-137
Overall dimensionsbull Irradiator 800times500times500 mmbull Guide rails length 30 mbull Height 16 mbull Weight not more than 700 kgbull Required room dimensions not less than 7x3x3 m
Electrical characteristicsPower supply bull 220 V 50 Hz
UPGD-2M-D
Reference standards IEC 60846 IEC 61526 IEC 61066
SPC ldquoDozardquo
78 79
Contents
MEASURING UNITS
DBG-S11D wide range gamma area monitor 40
UDKS-100 gamma and X-ray area monitor 41
UDMN-100 neutron area monitor 41
ALARM UNITS
BAS-2 ldquoMICROrdquo external visual alarm 42
BZS-2 ldquoMicrordquo external audible alarm 42
Illuminated warning signs 43
ldquoImpulsrdquo external display unit 43
UIM-3D area monitor count rate meter 44
DKG-05D personal gamma dosimeter 46
DVS-02D gamma-neutron personal electronic dosimeter 47
DVGI-8D new pen-type personal ionization chamber dosimeters 48
DKG-02U ldquoARBITERrdquo wide range gamma-dosimeter 49
DKG-07D ldquoDROZDrdquo gamma-dosimeter 50
MKS-15D ldquoSNEGIRrdquo multi ndash purpose radiation survey meter 51
SRPS-05D gamma monitor 52
DOZA-TLD multipurpose TLD system 53
DKS-96 universal radiation survey meter 54
EXTERNAL PROBES ALPHA
Alpha BDZA-96 55
Alpha BDZA-96B 55
Alpha BDZA-96M 55
Alpha BDZA-96S 55
Alpha BDZA-96T 55
EXTERNAL PROBES BETA
Beta BDZB-96 56
Beta BDZB-99 56
Beta BDZB-96B 56
Beta BDZB-96S 56
EXTERNAL PROBES GAMMA
Gamma BDKS-96B 57
Gamma and beta BDKS-96S 57
Gamma BDMG-96 57
EXTERNAL PROBES GAMMA
Gamma-search BDVG-96 58
Gamma-search BDPG-96 58
ContentsRadiation monitoring systemldquoPELIKANrdquo Radiation monitoring system (RMS) 6
BDMG-101 high range gamma area monitor 10
DBG-S11D wide range gamma area monitor 11
BDRG-52 high range gamma area monitor for accident and post-accident conditions 12
UDGP-01 Liquid technological environments monitor 13
UDMN-100 neutron area monitor 14
UDKG-100 Wel Liquid gamma monitor 14
BOP-1M data processing and transmission unit 15
UDA-1AB particulate monitor 16
UDG-1B noble gas monitor 17
UDG-03D noble gas monitor 18
UDI-1B iodine monitor 19
UDGB-01 noble gasesH-3C-14 monitor 20
UDGP-01 steam generator leakage monitor 21
UPPVM air flow parameters monitor 22
ldquoIMPULSrdquo external display unit 23
BI-2 remote display amp alarm unit 24
BASBAS-1s external alarm 25
SKGAV stack monitor 26
RMS software 28
RMS workstation ndash operator console 29
Configurator software 29
RM RACK radiation monitoring rack 30
SRKS-01D criticality accident alarm system 32
ldquoATLANT-Mrdquo environmental radiation monitoring system 34
ldquoBREEZErdquo high-volume air sampler 35
ldquoGAMMA-SENSORrdquo gamma-survey system 36
Radiation monitoring equipmentAREA MONITOR ldquoFREGATrdquo 38
BPI-1D local display unit 39
80
Gamma-search BDPG-96M 58
Gamma BDKG-96 stainless steel casing for geologic applications well logging 59
EXTERNAL PROBES NEUTRON
Neutron BDMN-96 59
Neutron-search BDKN-96 59
RZB-05D Hand-foot-clothing monitor 60
RZBA-04-04M whole body contamination monitor 61
RZA-05D alpha hand-monitor 62
UMF-2000 low level alpha- beta- counter 63
DRK dose area product meter 64
ldquoPROGRESS-BETArdquo scintillation beta spectrometer 65
ldquoPROGRESS-GAMMArdquo scintillation gamma spectrometer 66
ldquoPROGRESS-G(P)rdquo portable scintillation gamma spectrometer 67
ldquoPROGRESS-ARrdquo alpha radiometer 68
ldquoPROGRESSrdquo whole body counter 69
MKG-01D ldquoSADOVNIKrdquo spectrometry system 70
MKS-01A ldquoMULTIRAD-ASrdquo alpha spectrometer 71
UCRV-2 airflow monitor 72
PVP-06 portable air sampler 73
ldquoALPHARAD PLUSrdquo radon thoron amp their progeny monitor 74
UPG-P desktop gamma beam irradiator 75
UPGD-2M-D gamma beam irradiator 76
UKPN-2M-D neutron beam irradiator 77
SPC ldquoDozardquoRadiation monitoring equipment
46 47Reference standards Nuclear IEC 61526
Measurement of gamma-radiation personal dose equivalent Hp(10)bull Stand-alone dosimeter or composed of dosimetric
system onebull Audible and visual alarmbull Large memory dose accumulation historiesbull Exclusion of unauthorized intervention in dosim-
etry operation
DKG-05D PERSONAL GAMMA DOSIMETER
Physical characteristicsDetectors bull Silicon
Measurement range bull Dose rate 1 μSvh divide 10 Svhbull Dose 01 μSv divide 15 Sv
Energy range bull 005 divide 30 MeV
Electrical characteristicsbull Power supply rechargeable NiMH battery 1
alcaline battery (type AAA)
Operation timebull Till recharging not less 400 hoursbull With one set batteries not less 1000 hours
Mechanical characteristicsOverall dimensions weight bull 47times26times87 mm (with clip) 70 g
Environmental characteristicsbull IP65bull Temperature range minus 20 divide +45 ordmCbull Humidity up to 98 at 35 ordmCbull Shock vibration and drop resistant
Alarmbull Excess of alarm thresholdsbull Warnings of self-test failure and battery discharge bull Audible alarm 80 dB at 40 cmbull Visual alarm blinking LED
Relative equipmentbull One dosimeter charger ZU-1Mbull Chargestorage cassetes KZU-28KZU-56bull ldquoSmart chargingrdquo feature extends battery life timebull DKG-05D reader US-05bull DKG-05D system reader DVS-01D
Reader-PC interfacebull US-05 USB bull DVS-01D Ethernet
KZU-28
Physical characteristicsDetectors bull Silicon Li-6
Gamma measurement range bull Dose rate 1 μSvh divide 10 Svhbull Dose 01 μSv divide 15 Sv
Gamma energy range bull 005 divide 60 MeV
Neutron measurement range bull Dose rate 1 μSvh divide 2 Svhbull Dose 20 μSv divide 15 Sv
Neutron energy range bull 0025 eV divide 20 MeV
Electrical characteristicsPower supply bull Rechargeable NiMH batterybull Operatiion time till recharging not less 200 hours
Mechanical characteristicsOverall dimensions weight bull 47times26times87 mm (with clip) 70 g
Environmental characteristicsbull IP65bull Temperature range minus 20 divide +40 ordmCbull Humidity up to 75 at 30 ordmCbull Shock vibration and drop resistant
Alarmbull Excess of alarm thresholds bull Warnings of self-test failure and battery discharge bull Audible alarm 80 dB at 40 cmbull Visual alarm blinking LED
Relative equipmentbull One dosimeter charger ZU-1Mbull Chargestorage cassetes KZU-28 KZU-56bull ldquoSmart chargingrdquo feature extends battery life timebull DVS-02D reader UZS-01Sbull DVS-02D system reader DVS-01D
Reader-PC interfacebull UZS-01S USB bull DVS-01D Ethernet
UZS-01DReference standards Nuclear IEC 61526
DVS-02D GAMMA-NEUTRON PERSONAL ELECTRONIC DOSIMETER
Measurement of gamma- and neutron radiations personal dose equivalent Hp(10)bull Stand-alone dosimeter or composed of dosimetric
system onebull Audible and visual alarmbull Large memory dose accumulation historiesbull Exclusion of unauthorized intervention in dosim-
etry operationbull Both albedo thermal neutrons and intermediate
fast neutrons registrationbull Usable in the fields of Pu(Be) Po(Be) Cf and other
neutron sources as well as near nuclear reactors without neutron spectrum estimation
SPC ldquoDozardquoRadiation monitoring equipment
48 49
Dosimeters DVG-03D
DVGI-8D NEW PEN-TYPE PERSONAL IONIZATION CHAMBER DOSIMETERS
Measurement of personal dose equivalent Hp(10) of gamma and X-ray radiationbull Hp(10) of continuous and pulsed gamma and
X-ray radiation bull Electronic reader KSU-1bull Dosimeter DVG-03D with electronic ID bull Personal dose histories in the readerrsquos memorybull Readerrsquos connection with PC for database main-
tenance
Physical characteristicsDetector bull Ionization chamber
Measurement range bull 001 mSv divide 25 mSv
Energy range bull 0015 divide 25 MeV
Temperature range bull Reader KSU-1 +10 divide +50 ordmСbull Dosimeter DVG-03D minus 40 divide +50 ordmС
Electrical characteristicsPower supply bull Reader KSU-1 220 V 50 Hz built-in batteries bull Dosimeter DVG-03D four batteries CR 1025 bull Batteries life 3 yearsbull Readers interfaces RS-232USB 20
Mechanical characteristicsOverall dimensions weightbull Dosimeter DVG-03D Oslash 18times126 mm 005 kgbull Reader KSU-1 235times232times125 mm 28 kg
Reference standards Nuclear IEC 62387-1
DKG-02U ldquoARBITERrdquo WIDE RANGE GAMMA-DOSIMETER
Physical characteristicsDetectors bull GM counters
Measurement rangebull Dose-rate 01 μSvh divide 3 Svhbull Dose 1 μSv divide 100 Sv
Energy range bull 005 divide 3 MeV
Electrical characteristicsbull Power supply 2 alcaline batteries (type AA)bull Batteries life not less 200 hours
Mechanical characteristicsOverall dimensions weight bull 152times82times32 mm 03 kg
Environmental characteristicsbull Temperature range minus 20 divide +50 ordmCbull Humidity up to 90 at +25 ordmCbull Shock vibration and drop resistant
Reference standards Nuclear IEC 60846
Measurement of gamma radiation ambient equiva-lent dose H(10) and dose rate H(10)bull Audible signals (clicks) for radiation condition
estimationbull Analog scale for search modebull Audible and visual alarms of the excess of preset
dose and dose rate thresholds bull Shock-resistant water-proof easy decontamina-
tion casebull 100 measurement results memory with date and
time of measurementbull Indication of total dose accumulated during
exploitation time bull Indication of measurement result statistical
uncertainty
SPC ldquoDozardquoRadiation monitoring equipment
50 51
Physical characteristicsDetectors bull GM counter
Measurement rangebull Dose-rate 01 μSvh divide 3 mSvhbull Dose 1 μSv divide 02 Sv
Energy range bull 005 divide 3 MeV
Temperature range bull Minus 20 divide +50 ordmC
Electrical characteristicsbull Power supply 2 alcaline batteries 15 V (type AA)bull Batteries life not less 200 hours
Mechanical characteristicsOverall dimensions weight bull 122times74times29 mm 025 kg
Reference standards Nuclear IEC 60846
DKG-07D ldquoDROZDrdquoGAMMA-DOSIMETER
Measurement of gamma radiation ambient equiva-lent dose H(10) and dose rate H(10)bull Two independent measurement channels dose
and dose ratebull Audible signals (clicks) for radiation condition
estimationbull Continuous measurement with updating meas-
urement resultbull Measurement result can be obtained with any
desired statistical uncertainty (error)bull Automatic restart when radiation level sharply
changesbull Indication of statistical uncertainty (error) during
measurement process
Continuous measurement with updating measure-ment result
Automatic restart when radiation level sharply changes bull Gamma dose H(10) and dose-rate H(10) meas-
urementbull Beta and gamma contamination surveybull Indication of statistical uncertainty during the
measurementbull Continuous measurement with accuracy increas-
ing with time bull Automatic restart triggered by change of gamma
dose-ratebull Compensation of gamma count rate while meas-
uring beta radiationbull Indication of battery charge levelbull Audible signal of the excess of preset threshold
Physical characteristicsDetectors bull GM counter
Measurement range bull Dose-rate 01 microSvh divide 20 mSvhbull Dose 1 microSv divide 100 Svbull Beta flux density (for Sr-90+Y-90)
10 divide 105 cm-2 min-1
Energy range bull Gamma 005 divide 3 MeVbull Beta 01 divide 3 MeV
Temperature range bull Minus 20 divide +50 ordmC
MKS-15D ldquoSnegirrdquo backside
MKS-15D ldquoSNEGIRrdquoMULTI ndash PURPOSE RADIATION SURVEY METER
Reference standards Nuclear IEC 60846 IEC 60325
Electrical characteristicsbull Power supply 2 alcaline batteries (type AA)bull Battery life not less 400 hours
Mechanical characteristicsOverall dimensions weight bull 124times72times35 mm 035 kg
SPC ldquoDozardquoRadiation monitoring equipment
52 53
Physical characteristicsDetectorbull GM counter
Measurement range bull 01 μSvh divide 20 mSvh
Energy range bull 005 divide 30 MeV
Threshold setting range bull 03 μSvh divide 20 mSvh
Step change of the thresholdbull In the range 03 divide 10 μSvh with the step
001 μSvhbull In the range 10 divide 100 μSvh with the step
01 μSvhbull In the range 100 divide 2000 μSvh with the step
10 μSvh
Electrical characteristicsPower supply bull 220 V 50 Hz bull Relay output
Mechanical characteristicsProtection index bull IP 40
Overall dimensions weight bull 226times120times75 mm 07 kg
Alarmbull Sound alarm 80 divide 100 dBA at distance 1 mbull Visual alarm redbull Connection of the external alarm signaling unit
Reference standards Nuclear IEC 60846 IEC 60532
Continuous automatic monitoring of the ambient dose equivalent rate bull Measurement of gamma dose rate H(10)bull Audible and visual alarm signals for preset
thresholdsbull Switching on the external signaling or executive
devices
SRPS-05D GAMMA MONITOR
Measurement ofbull Gamma and X-ray personal dose equivalent
Hp(10)bull Neutron personal dose equivalent Hp(10)bull Lens dose equivalent Hp(3)bull Skin dose equivalent Hp(007)bull TLD reader day-to-day tests using built-in LEDbull No needs nitrogen for heating
Physical charachteristicsDetectors bull 7LiF Mg Ti (gamma beta)bull 6LiF Mg Ti (neutron)
Gamma and X-ray Hp(10) Measurement range bull 500 μSv divide 10 Sv
Energy range bull 0015 divide 30 MeV
Neutron Hp(10)Measurement range bull 01 mSv divide 100 mSv
Energy range bull 0025 eV divide 10 MeV
Beta and photons Hp(007) Hp(3) Measurement range bull 2 mSv divide 100 Sv
Energy range bull Beta 025 divide 35 MeVbull Photons lt15 keV
Mechanical characteristicsDosimeters overall dimensions weight bull Gamma Hp(10) DTL-2 holder - 62times26times16 mm
16 gbull DTU holder - 42times28times18 mm 8 gbull Lens Hp(3) face skin Hp(007) Oslash 32times16 mm 9 gbull Finger skin Hp(007) 90times20times2 mm 1 gbull Neutron gamma Hp(10) 48times40times20 mm 30 g
Reference standards Nuclear IEC 61066
DTL-2 DTU-2
MKD (A-type) DVNG-M
DOZA-TLD MULTIPURPOSE TLD SYSTEM
SPC ldquoDozardquoRadiation monitoring equipment
54 55
Continuous and pulsed gamma and X-ray dose H(10) and dose-rate measurementbull Alpha beta and gamma contamination surveybull Neutron dose H(10) and dose-rate measurementbull Gamma radiation flux density in boreholes and
liquid media measurement
Electrical characteristicsPower supply bull UIK-05 four C-size batteriesbull UIK-05-01 rechargeable batterybull UIK-06 rechargeable battery
Interfaces bull RS-232bull USB (via adapter)
bull Detector type automatic determination and corre-sponding measurement modes selection
bull Alarm threshold settings ndash for dose dose-rate alpha and beta contaminations
bull ldquoDetectrdquo and ldquoLocaterdquo modes for survey probes
Reference standards Nuclear IEC 60846 IEC 60325 IEC 61005 IEC 62363
Case
UIK-06 control unit165times78times48 mm 03 kg
DKS-96UNIVERSAL RADIATION SURVEY METER
UIK-05 control unit202times86times90 mm 10 kg
BDZA-96
BDZA-96B
BDZA-96M
BDZA-96S
BDZA-96T
EXTERNAL PROBES ALPHAALPHA BDZA-96Detector bull ZnS(Ag) 70 cm2
Measurement range (for Pu-239)bull 01 divide 104 min-1cm-2
Overall dimensions weightbull Oslash 130times240 mm 11 kg
ALPHA BDZA-96BDetector bull ZnS(Ag) 300 сm2
Measurement range (for Pu-239)bull 01 divide 2103 min-1cm-2
Overall dimensions weightbull Oslash 230times290 mm 40 kg
ALPHA BDZA-96MDetector bull ZnS(Ag) 10 сm2
Measurement range (for Pu-239)bull 01 divide 105 min-1cm-2
Overall dimensions weightbull Oslash 65times240 mm 09 kg
ALPHA BDZA-96SDetector bull ZnS(Ag) 30 сm2
Measurement range (for Pu-239)bull 01 divide 5104 min-1cm-2
Overall dimensions weightbull Oslash 90times240 mm 10 kg
ALPHA BDZA-96TDetector bull Silicon 5 сm2
Measurement range (for Pu-239)bull 01 divide 106 min-1cm-2
Overall dimensions weightbull Oslash 50times60 mm 015 kg
SPC ldquoDozardquoRadiation monitoring equipment
56 57
BETA BDZB-96Detector Scintillator 28 сm2
Measurement range (for Sr-90+Y-90)bull 10 divide 105 min-1cm-2
Energy rangebull 03 divide 30 MeV
Overall dimensions weightbull Oslash 90times230 mm 09 kg
BETA BDZB-99Detector bull GM counter 30 сm2
Measurement range (for Sr-90+Y-90)bull 20 divide 104 min-1см-2
Energy rangebull 012 divide 30 MeV
Overall dimensions weightbull Oslash 88times80 mm 04 kgbull Telescopic pole length 07 m
BETA BDZB-96BDetector bull GM counter 80 сm2
Measurement range (for Sr-90+Y-90)bull 3 divide 104 min-1сm-2
Energy rangebull 012 divide 30 MeV
Overall dimensions weightbull 150times200times110 mm 15 kg
BETA BDZB-96Sbull Detector GM counter 15 сm2
Measurement range (for Sr-90+Y-90)bull 10 divide 3104 min-1cm-2
Energy rangebull 012 divide 30 MeV
Overall dimensions weightbull Oslash 65times65 mm 03 kgbull Telescopic pole length 07 m
BDZB-96
BDZB-99
BDZB-96B
BDZB-96S
EXTERNAL PROBES BETA
GAMMA BDKS-96BDetector bull Tissue-equivalent scintillator Oslash 45times20 mm
Measurement rangebull Dose rate H(10) 01 μSvh divide 1 Svhbull Dose H(10) 01 μSv divide 10 Sv
Energy rangebull 0015 divide 10 MeV
Overall dimensions weightbull Oslash 60times250 mm 085 kg
GAMMA AND BETA BDKS-96SDetector bull Double GM counters
Measurement rangebull Gamma dose rate H(10) 01 μSvh divide 1 mSvhbull Gamma dose H(10) 01 μSv divide 10 Svbull Beta 10 divide 3104 min-1cm-2
Energy rangebull Gamma 005 divide 3 MeVbull Beta 012 divide 3 MeV
Overall dimensions weightbull Oslash 80times80 mm 035 kgbull Telescopic pole length 07 m
GAMMA BDMG-96Detector bull GM counters
Measurement rangebull Dose rate H(10) 01 μSvh divide 10 Svhbull Dose H(10) 01 μSv divide 10 Sv
Energy range bull 005 divide 3 MeV
Overall dimensions weightbull 40times250 mm 05 kgbull Telescopic pole length 07 m 4 m (by request)
EXTERNAL PROBES GAMMA
BDKS-96B
BDMG-96
BDKS-96S
SPC ldquoDozardquoRadiation monitoring equipment
58 59
GAMMA-SEARCH BDVG-96Detector bull Scintillator NaI(Tl) Oslash 63times63 mm
Measurement rangebull Flux density measurement range 4 divide 2000 s-1cm-2
bull Dose rate H(10) for Cs-137 01 divide 30 μSvhbull Sensitivity for Cs-137 3000 (pulsess-1)( μSvh-1)
Overall dimensions weightbull Oslash 88times400 mm 20 kgbull Modular pole length 16 m
GAMMA-SEARCH BDPG-96Detector bull Scintillator NaI(Tl) Oslash 25times40 mm
Measurement rangebull Flux density measurement range 10 divide 8000 s-1cm-2
bull Dose rate H(10) for Cs-137 01 divide 100 μSvhbull Sensitivity for Cs-137 500 (pulsess-1)( μSvh-1)
Overall dimensions weightbull 50times190times480 mm 10 kgbull Telescopic pole length 07 m
GAMMA-SEARCH BDPG-96MDetector bull Scintillator NaI(Tl) Oslash 18times30 mm
Measurement rangebull Flux density measurement range 10 divide 24000 s-1cm-2
bull Dose rate H(10) for Cs-137 01 divide 300 μSvhbull Sensitivity for Cs-137 200 (pulsess-1)( μSvh-1)
Overall dimensions weightbull Oslash 35times320 mm 05 kgbull Telescopic pole length 07 or 38 m
EXTERNAL PROBES GAMMA
BDVG-96
BDPG-96M
BDPG-96
EXTERNAL PROBESGAMMA BDKG-96 STAINLESS STEEL CASING FOR GEOLOGIC APPLICATIONS WELL LOGGINGDetector bull Scintillator NaI(Tl) Oslash 18times30 mm
Measurement rangebull Flux density measurement range 10 divide 105 s-1cm-2
bull Dose rate H(10) for Cs-137 5 divide 2104 μRhbull Sensitivity for Cs-137 200 (pulsess-1)( μSvh-1)
Overall dimensions weightbull Oslash 38times535 mm 36 kgbull Cable length 10 divide 1000 m
NEUTRON BDMN-96Detector bull Scintillator with ZnS(Ag)
Measurement rangebull Dose rate H(10) 01 μSvh divide 01 Svhbull Dose H(10) 01 μSv divide 10 Sv
Energy range bull 0025 eV divide 10 MeV
Overall dimensions weightbull Detector Oslash 54times200 mm 08 kgbull Moderator Oslash 245 mm 73 kg
NEUTRON-SEARCH BDKN-96Detector bull He-3 counter in polyethilene moderator
Measurement rangebull Dose rate H(10) for Pu-Be 01 μSvh divide 01 Svhbull Dose H(10) for Pu-Be 01 μSv divide 10 Sv
Energy range bull 0025 eV divide 14 MeV
Overall dimensions weightbull 295times142times100 mm 225 kg
BDKG-96M
BDMN-96
BDKN-96
SPC ldquoDozardquoRadiation monitoring equipment
60 61
bull No gas supply neededbull Clothing control detachable right hand detector bull Alpha detector optional connection bull Numeric and color (red green) indication of
control resultsbull LED sensor of hand-foot positioning for start of
measurementbull Automatic compensation of gamma background
and contamination of detectorbull Audible alarm signals of the excess of preset
thresholdsbull Measurement value indication min-1cm-2 or
Bqсm2
Reference standards Nuclear IEC 61098
RZB-05D HAND-FOOT-CLOTHING MONITOR
Physical characteristicsDetectors bull Gamma beta - GM countersbull Alpha - scintillatior ZnS(Ag)
Detecting nuclidesbull Alpha Pu-239 U-234 U-238bull Beta Sr-90+Y-90 F-18 Cs-137 Co-60 Tс-99 O-15
N-13 Sr-89 C-11 I-131 Na-22 Ru-106+Rh-106 Tl-204
bull Gamma Tc-99m I-123
Efficiencybull Alpha
Pu-239 40 U-234 25U-238 15
bull Beta Sr-90 +Y-90 40
Measurement range bull Alpha 1 divide 103 min-1cm-2 bull Beta 10 divide 103 min-1cm-2
bull Gamma 5103 divide 5106 min-1cm-2
Energy range bull Alpha 30 divide 80 MeV bull Beta 008 divide 35 MeV bull Gamma 005 divide 30 MeV
Operation temperature range bull Minus 10 divide +50 ordmС
Electrical characteristicsbull Power supply 220 V 50 Hz
Mechanical characteristicsOverall dimensions weight bull 740times750times1180 mm 45 kg
Versionsbull Withwithout alpha detectorbull Indication (min-1cm-2 ) or (Bqсm2)bull Detectors overall dimensions smbull Hand 178 х 235bull Foot 185 х 436
Whole body contamination monitor RZBA-04-04Mbull No gas supply neededbull Compensation for background gamma radiation
and contamination of detector unitsbull Individual threshold setting for each measure-
ment channelbull Visible and audible alarms ldquoCONTAMINATIONrdquo and
ldquoCLEANrdquo bull Indication of contaminated body parts on the
panel with image of the bodybull Optional remote alpha-detector
Physical characteristicsDetectors bull Beta - GM counters scintillatorsbull Alpha - scintillatior ZnS(Ag)
Measurement range bull Beta 5 divide 15000 min-1cm-2
bull Alpha 01 divide 10000 min-1cm-2
Energy range bull Beta 015 divide 25 MeV bull Alpha 40 divide 56 MeV
Operation temperature range bull +5 divide +50 ordmС
Electrical characteristicsPower supply bull 220 V 50 Hz
Interfaces bull RS-232bull RS-485
Mechanical characteristicsOverall dimensions weight bull 2650times940times930 mm 310 kg
Versionsbull Withwithout alpha detectorbull Indication (min-1cm-2 ) or (Bqсm2)
Reference standards Nuclear IEC 61098
RZBA-04-04MWHOLE BODY CONTAMINATION MONITOR
SPC ldquoDozardquoRadiation monitoring equipment
62 63
RZA-05DALPHA HAND-MONITOR
bull No gas supply needed bull Numeric and color (red green) indication of
control resultsbull LED sensor of hand- positioning for start of
measurementbull Audible alarm signals of the excess of preset
thresholdsbull Measurement value indication min-1cm-2 or
Bqсm2
Physical characteristicsDetectors alpha - scintillatior ZnS(Ag)
Efficiencybull Pu-239 20 bull U-234 14bull U-238 8
Measurement range bull 05 divide 105 min-1cm-2
Energy range bull 41 divide 90 MeV
Operation temperature range bull minus 10 divide +50 ordmС
Electrical characteristicsPower supply bull 220 V 50 Hz
Mechanical characteristicsOverall dimensions weight no more bull 740times1400times1450 mm 70 kg
Reference standards Nuclear IEC 61098
bull Simultaneous measurement of alphabeta activi-ties in the sample
bull Active shielding anti-coincidence background subtraction using GM counters
bull Lead shielding 30 mm
UMF-2000 LOW LEVEL ALPHA- BETA- COUNTER
Physical characteristicsDetectors bull Silicon specrometric detector 500 or 1000 mm2
Measurement range bull Alpha 001 divide 1000 Bq bull Beta 01 divide 3000 Bq
Energy range bull Alpha 35 divide 80 MeV bull Beta 005 divide 35 MeV
Electrical characteristicsPower supply bull 220 V 50 Hz
Interfaces bull RS-232bull USB
Mechanical characteristicsOverall dimensions weight bull 337times286times190 mm 22 kg
Versionsbull Detector area 500 mm2
bull Detector area 1000 mm2
UMF-2000 Detector area 1000 mm2
UMF-2000 Detector area 500 mm2
SpectraDec software for alpha-spectrometric measurements
SPC ldquoDozardquoRadiation monitoring equipment
64 65
DRK DOSE AREA PRODUCT METER
DRK-1bull Diagnostic reference level (DRL) of patients
determinationbull Suitable for all basic types of x-ray machines
Physical characteristicsDetector bull Plane-parallel ionization chamber
Measurement range bull 1 divide 104 cGycm2
Electrical characteristicsPower supply bull 220 V 50 Hz
DRK-1M-CTbull Measuring of dose length product
Physical characteristicsDetector bull Pencil Ionization Chamber
Measurement rangebull 05 divide 109 microGym
DRK-1Mbull Measuring of air kerma on sectional area of the
X-ray beam productbull Measuring of air kerma rate on area productbull Measuring of air kerma ratebull Measuring of air kerma
Physical characteristicsDetector bull Plane-parallel ionization chamber
Measurement rangebull 01 divide 109 microGym2
bull 06 divide 6104 microGym2cbull 30 divide 9105 microGycbull 30 divide 9991011 microGyReference standard IEC 60580 2003
bull Measurement of strontium-90 in the foodstuffs agricultural products etc
bull Measurement of gross beta activity in samplebull Self tests using built-in LED
ldquoPROGRESS-BETArdquo SCINTILLATION BETA SPECTROMETER
Physical characteristicsDetector bull Plastic scintillator Oslash70x10 mm
Sample bull Plate Oslash70 mmbull Weight up to 15 g
Energy range bull 02 divide 30 MeV
Minimum detectable activity of Sr-90 in a 10 g sample on a standard planchet Bqsamplebull In case of absence of K-40 in the sample 01 Bqbull In case the activity of K-40 till 5 Bqg 05 Bq
Electrical characteristics Interface bull USB
Mechanical characteristicsWeight bull No more 50 kg
Complete setBasic complete setbull Detector unit with plastic scintillator integrated
power supply amplifier ADC bull Lead shielding bull ldquoProgressrdquo software bull Сheck source for energetic calibration (Sr-90-Y-90) bull Planchet Oslash 70 mm (5 items) bull Sample dencification device bull Procedure manual for measurement of radio-
nuclidesrsquo activity using the scintillation beta spec-trometer ldquoProgressrdquo
Optional equipment and servicebull Personal computer and printer bull Calibrations for radionuclides not included in the
main library of radionuclides
Progress-Beta
Reference standards IEC 61562
SPC ldquoDozardquoRadiation monitoring equipment
66 67
bull Measurement of gamma activity in foodstuffs soil samples and others environmental objects
bull Identification of radionuclides in the sample bull Automatic correction for sample density bull Self-tests using built-in LED
ldquoPROGRESS-GAMMArdquoSCINTILLATION GAMMA SPECTROMETER
Physical characteristicsDetector bull NaI (Tl) Oslash63times63 mm
Validated measurement geometries bull Marinelli beakers (1 liter) Petri dishes (Oslash90 mm)
etc
Energy range bull 02 divide 30 MeV
Minimum detectable activity Bqsamplebull Cs-137 3 Bqbull Th-232 7 Bqbull Ra-226 8 Bq bull К-40 40 Bq
Electrical characteristics Interface bull USB
Mechanical characteristicsWeight bull No more 120 kg
Complete setBasic complete setbull Scintillation detector unit with NaI (Tl) detector
with integrated power supply amplifier and ADC bull Lead shielding 50 mm bull ldquoProgressrdquo software bull Сheck source for energy calibration (Cs-137 +
K-40)bull Marinelli beakers - 1 liter (5 items) bull Petri dishes Oslash 90 mm (5 items) bull Procedure manual for measurement of activity
of radionuclides using the scintillation gamma spectrometer ldquoProgressrdquo
Optional equipment and servicebull Kit for radon measurements including calibration
of ldquoIC-63rdquo geometry for counting the charcoal samples
bull Personal computer and printer bull Calibrations for user defined geometries bull Calibrations for radionuclides not included in the
main library of radionuclides
Progress-Gamma
Reference standards IEC 61563
ldquoPROGRESS-G(P)rdquoPORTABLE SCINTILLATION GAMMA SPECTROMETERbull Field measurements of gamma activity in environ-
mental objects without sampling (4π geometry)bull Laboratory measurement of gamma activity in
foodstuffs soil samples and others environmental objects
bull Identification of radionuclides in the sample bull Automatic correction for sample densitybull Tests using built-in LED
Physical charachteristicsDetector bull NaI (Tl) Oslash45times50 mmbull Lead shielding 20 mm
Validated measurement geometries bull Marinelli beakers (05 liter) Petri dishes (Oslash90 mm)
etc
Energy range bull 02 divide 30 MeV
Minimum detectable activity in 05-litre Marinelli beaker bull Cs-13710 Bqkgbull К-40100 Bqkgbull Ra-22618 Bqkg bull Th-23216 Bqkg
Minimum detectable activity in 30 min (4π geometry) bull Cs-137 2 Bqkgbull К-40 30 Bqkgbull Ra-226 4 Bqkg bull Th-232 3 Bqkg
Electrical characteristicsPower supply bull Rechargeable batterybull 220 V 50 Hz
Interface bull USB RS-232
Weight bull No more than 60 kg
Complete setBasic complete setbull Scinttillation detector unit with NaI(Tl) bull ldquoProgressrdquo softwarebull Сontrol unit ldquoSputnikrdquo for aquisition and analisys
of spectra with built-in memory for spectral databull Casebull Lead shielding (2 cm) for laboratory usebull 05-litre Marinelli beakers ndash 5 itemsbull Na-22 check sourcebull Power adapter BPS-01bull Operation manualbull Procedure manual for measurement of activity
of radionuclides using the scintillation gamma spectrometer ldquoProgressrdquo
Optional equipment and servicebull Kit for radon measurements with charcoalbull Built-in dose rate meterbull Additional memory (RAM) for storage of 64
spectrabull Additional power adapterbull Notebook and printer
Progress-Gamma
Reference standards IEC 61563
SPC ldquoDozardquoRadiation monitoring equipment
68 69
Physical characteristicsDetectorbull Scintillation detector ZnS (Oslash 60 mm)
Samplebull Thin sample - diameter up to 70 mm bull Preparation technique - electro-depositionbull Thick sample - diameter 70 mm weight
200300 mg bull Preparation technique - application of powders
(prepared by radiochemical concentration by water evaporation or by pounding of mineral samples) onto a planchet with the help of spirit
Energy rangebull 15 divide 8 MeV
Minimum detectable activitybull Thin samples no more than 910-3 Bqsamplebull Thick samples no more than 180 Bqkg
Mechanical characteristicsOverall dimensions weightbull 195times120times210 mm 34 kg
Complete setBasic complete setbull Alpha radiometer ldquoProgress-ARrdquobull Check source (uranium isotopes)
Set of accessoriesbull Procedure manual for measurements of radi-
oactivity using scintillation alpha radiometer ldquoProgress-ARrdquo
bull ldquoProgressrdquo software
ldquoProgress-ARrdquo
bull Measurement of gross activity of alpha emitting radionuclides in thin samples
bull Measurement of gross activity of alpha emitting radionuclides in thick samples
bull Measurement of activity deposited on aerosol filters
ldquoPROGRESS-ARrdquoALPHA RADIOMETER
Several fixed positions of the detector enable to perform measurements in various geometries and to estimate the content ofbull Cs-137 in the whole bodybull I-131 in thyroidbull Co-60 Cs-137 Mn-54 Cr-51 in lungsbull Database for storage of measurement data and
resultsbull Uncertainty calculations based on measurement
databull Self tests using built-in LED
ldquoPROGRESSrdquo WHOLE BODY COUNTER
Physical characteristicsDetectorbull scintillation detector NaI (Tl) Oslash63times63 mm
Energy rangebull 02 divide 28 MeV
Minimum detectable activitybull By Cs-137 in the whole body - 1200 Bqbull By I-131 in thyroid - 100 Bqbull By Co-60 Cs-137 Mn-54 Cr-51 in lungs - 200 Bq
Mechanical characteristicsWeight bull No more than 120 kg
Complete setBasic complete setbull Collimator with rotator and holderbull Detector with incorporated ADCbull Patient chair and table for collimatorbull Check source Na-22bull Procedure manual for lifetime measurement of
gamma-emitting radionuclidesrsquo activity in human body using the gamma-spectrometer of human radiation ldquoProgressrdquo
bull laquoProgressraquo software
Optional equipment and servicebull Program of internal radiation committed internal
radiation effective dose calculation by the stand-ard model
bull Background phantombull Personal computer and printer
Collimator with rotator and holder
SPC ldquoDozardquoRadiation monitoring equipment
70 71
bull Categorization of wastes for the purpose of fur-ther processing including wastes with unknown radionuclide composition
bull Measurements during the incoming waste inspec-tion (accepting for storage disposal)
bull Certification of unconditioned and conditioned wastes in closed containers without opening them (at nuclear plants or at facilities providing collection storage transportation conditioning processing temporal storage and final disposal of radioactive waste)
bull Activity measurement of extended objects in situ without opening the equipment
bull Activity measurement of extended objects after opening (for example assessment of tubes used for oil transportation)
MKG-01D ldquoSADOVNIKrdquoSPECTROMETRY SYSTEM
Physical charachteristicsDetectorbull Detector unit GEM (GMX) with HPGe detector and
multi-positioning cryostat CFG-PMOD4-7 with 7 litre Dewar
bull Dose rate probe BDMG-200
Energy range bull With GEM detector 004 divide 30 MeVbull With GMX detector 0005 divide 15 MeVbull Dose rate probe BDMG-200 ndash 005 divide 30 MeV
Measurement rangebull 110-7 divide 10 Svhbull Relative efficiency of detection (in photopeak) at
13325 MeV (Co-60) 10 divide 150
Electrical characteristicsPower supplybull 220 V 50 Hz
Interfacebull USB
Complete setBasic complete setbull Spectrometric detector unit GEM (GMX) with
HPGe detector and multi-positioning cryostat with 7 litre Dewar
bull Portable digital multichannel analyzer DigiDARTbull Dose rate probe BDMG-200bull Autonomous power supply unit with built-in
batterybull Industrial computer keyboardbull Laser range-finderbull Thermographic printerbull Web-camerabull Device equipped with stepper motor for position-
ing of the spectrometric detectorbull Calibration device with reference sources
(Am-241 Co-60 Ba-133 Eu-152) for energy calibration
bull Removable collimators with end capbull Measurement proceduresbull ldquoClasterrdquo software
bull Measurement of gross alpha activity of alpha-emitting radionuclides
bull Measurement of alpha-emitting radionuclides activity in thin-layer samples meeting alpha-spectrometry requirements
Physical characteristicsDetectorbull Silicon ion-implanted 450 mm2
bull Easy to decontaminate thin windowbull dead layer less than 015 μmbull Background count rate in the range 3 divide 9 MeVbull No more than 09 h-1cm-2 for 450 mm2 detector
Energy rangebull 2 divide 9 MeVbull Lower limit of measurement range (minimum
detectable activity) 01 Bqbull Background count rate no more than 100 counts
in 24 hours
Electrical characteristics Power supplybull 220 V 50 Hz
Interfacebull USB
Complete setBasic complete setbull Detector unit with vacuum measuring chamber
and vacuum control systembull Low noise vacuum pump (type 2FY-05B or
equivalent)bull Check sourcebull ldquoProgressrdquo softwarebull Vacuum tube
MKS-01A ldquoMULTIRAD-ASrdquoALPHA SPECTROMETER
SPC ldquoDozardquoRadiation monitoring equipment
72 73
UCRV-2AIRFLOW MONITOR
bull Monitor of the air flow through filter of centralized multichannel sampling system
bull Radiation monitoring system (RMS) integration for internal exposures determination
bull Volume and flow rate measurements of the air that have passed through a analytical filter
bull Bar-code for filter identificationbull Operation as either standalone unit or as a part of
the RMS
Physical characteristicsMeasurement range of air volume bull 001 divide 9999 m3
Operation temperature range bull minus 20 divide +50 ordmС
Electrical characteristicsPower supply bull 220 V 50 Hz
Interface bull RS-485
PVP-06PORTABLE AIR SAMPLER
Air Sampler PVP-06 is indispensable for monitoring the radiation situation where the concentration of radioactive aerosols in the air does not require a sta-tionary sampling equipment Sampling head PVP-06 provides easy change of filters and cartridges
Purposebull To monitor the concentration of radioactive aero-
sols in the air sites
Controlled aerosolsbull Alpha- and beta-active aerosolsbull Daughter products of decay of radon and thoronbull Iodine isotopes
Physical characteristicsTypes of filtersbull Aerosol AFA-RSP-20bull Iodine AFA SI-20
Flow rate bull 33∙10-4 ndash 233∙10-4 m3s (20 divide 140 l min)
Electrical characteristicsPower supply bull 220 V50 Hzbull The vehicle power supply 108 divide 145 Vbull Internal battery
Minimal working time on internal battery to recharge bull 8 hours
Power consumption (at a flow rate of 100 lmin) bull 40 VA
Environment characteristicsOperating temperature bull minus 10 divide +40 deg C
Maximum humidity bull 90
Pressure bull 860 to 1060 hPA
Noise generated by the pump bull lt 55 dBA at 1 m
Mechanical characteristicsDimensions weight bull 241 times 108 times 160 mm 28 kg
Case material bull Plastic
Complete setbull Air sampler PVP-06bull AC power adapterbull Filters AFA-RSP-20 - 100 pcsbull Packaging for filters - 40 pcsbull Casebull Operation manualbull Calibration certificate
Optional equimpient bull Kit for sampling sorption columns of activated
carbon Ř head of sorption columns with protective
covers Ř activated charcoal SKT-3 - 1 pkg (02 L) Ř charocoal samples SC-13 - 8 pcs
bull Car charger bull Tipod bull Shoulder strapbull Calibration stand bull Filters AFA SI-20 - 100 pcs
Consumablesbull Aerosol filters AFA RSP-20bull Iodine filters AFA SI-20
SPC ldquoDozardquoRadiation monitoring equipment
74 75
Calibration of gamma dose and dose rate meters
Calibration ofbull Ambient equivalent dose H(10) meters (Sv Svh)bull Personal equivalent dose Hp(10) meters (Sv Svh)bull Exposure dose X meters (R Rh)bull Two sources in irradiator bull Select source and collimator opening using
tumbler
UPG-P DESKTOP GAMMA BEAM IRRADIATOR
Physical characteristicsRange of reproduced dose rate bull 05 μSvh divide 10 mSvh (50 μRh divide 100 mRh)
Sources activities bull 6times106 6times108 Bq (02 20 mCi) Cs-137
Overall dimensions bull 1250times400times300 mm
Irradiator weight bull Not more than 37 kg
Calibration bench weight bull Not more than 15 kg
Reference standards IEC 60846 IEC 61526
Physical characteristicsDetectorbull Silicon
Measurement range EEC measurement bull Measurement range of radon EEC
10 divide 10bull106 Bqbullm-3
bull Measurement range of thoron EEC 05 divide 10bull104 Bqbullm-3
bull Air flow through the filter 100plusmn05 lmin
Concentration measurementbull Measurement range of radon-222 concentration
in air 10 divide 20bull106 cpsbull Measurement range of 216Po(ThA)
1bull10-3 divide 1bull102 cpsbull Air sampler flow rate
10plusmn02 lminbull Measurement range of radon-222 concentration
in water samples 6 divide 800 Bqbullkg-1
bull Measurement range of radon-222 flux from soil surface 20 divide 103 mBqsbullm2
bull Measurement range of radon-222 concentration with preliminary sampling of air using air sam-plers 20 divide 107 Bqbullm-3
bull Measurement range of radon-222 concentration in samples of soil air 103 divide 106 Bqbullm-3
Operation temperature range bull 1 divide 35 ordmC
Electrical characteristicsPower supply bull 80 VA
Mechanical characteristicsOverall dimensions weight bull 220times200times165 mm 36 kg
ldquoALPHARAD PLUSrdquoRADON THORON amp THEIR PROGENY MONITORbull Measurement of radon and thoron concentration
and effective equivalent concentration (EEC)bull In the airbull In the indoor air of residential public and industri-
al buildings and structuresbull Measurement of radon in drinking water sourcesbull Measurements of radon flux from the soil surface
at land plots allocated for construction of houses public buildings and industrial facilities
bull Measurements of radon concentration in soil air
Reference standards IEC 61577
SPC ldquoDozardquoRadiation monitoring equipment
76 77
UKPN-2M-D NEUTRON BEAM IRRADIATOR
Reference standards IEC 61005 61322
Calibration of neutron dose and dose rate meters
Calibration ofbull Ambient equivalent dose H(10) meters (Sv Svh)bull Personal equivalent dose Hp(10) meters (Sv Svh)bull Flux density of neutrons (cm-2∙s-1)bull Transfer container for temporary storage of
sources bull Red light signal of source working position
Physical carachteristicsRange of reproduced dose ratebull 20 divide 800 μSvh
Range of reproduced flux densitiesbull 10 divide 400 cm-2∙s-1
Type of a source in use bull Pu-Be
Activity of a source in usebull 24х1011 Bq (with density of 107 s-1)
Overall dimensions weight no morebull 3000x750x2000 mm 300 kg
Required room dimensionsbull not less than 7x3x3 m
Electrical characteristicsPower supply bull 220 V 50 Hz
Calibration of gamma dose and dose rate meters
Calibration ofbull Ambient equivalent dose H(10) meters (Sv Svh)bull Personal equivalent dose Hp(10) meters (Sv Svh)bull Exposure dose X meters (R Rh)bull Four sources in irradiator bull Select source and move to working position
return to storage position using special rodbull Transfer container for temporary storage of
sources bull Red light signal of source working position
UPGD-2M-DGAMMA BEAM IRRADIATOR
Physical characteristicsRange of reproduced dose rate bull 05 μSvh divide 50 mSvh (50 μRh divide 5 Rh)
Maximum activity of source bull 2times1011 Bq (50 Ci) Cs-137
Overall dimensionsbull Irradiator 800times500times500 mmbull Guide rails length 30 mbull Height 16 mbull Weight not more than 700 kgbull Required room dimensions not less than 7x3x3 m
Electrical characteristicsPower supply bull 220 V 50 Hz
UPGD-2M-D
Reference standards IEC 60846 IEC 61526 IEC 61066
SPC ldquoDozardquo
78 79
Contents
MEASURING UNITS
DBG-S11D wide range gamma area monitor 40
UDKS-100 gamma and X-ray area monitor 41
UDMN-100 neutron area monitor 41
ALARM UNITS
BAS-2 ldquoMICROrdquo external visual alarm 42
BZS-2 ldquoMicrordquo external audible alarm 42
Illuminated warning signs 43
ldquoImpulsrdquo external display unit 43
UIM-3D area monitor count rate meter 44
DKG-05D personal gamma dosimeter 46
DVS-02D gamma-neutron personal electronic dosimeter 47
DVGI-8D new pen-type personal ionization chamber dosimeters 48
DKG-02U ldquoARBITERrdquo wide range gamma-dosimeter 49
DKG-07D ldquoDROZDrdquo gamma-dosimeter 50
MKS-15D ldquoSNEGIRrdquo multi ndash purpose radiation survey meter 51
SRPS-05D gamma monitor 52
DOZA-TLD multipurpose TLD system 53
DKS-96 universal radiation survey meter 54
EXTERNAL PROBES ALPHA
Alpha BDZA-96 55
Alpha BDZA-96B 55
Alpha BDZA-96M 55
Alpha BDZA-96S 55
Alpha BDZA-96T 55
EXTERNAL PROBES BETA
Beta BDZB-96 56
Beta BDZB-99 56
Beta BDZB-96B 56
Beta BDZB-96S 56
EXTERNAL PROBES GAMMA
Gamma BDKS-96B 57
Gamma and beta BDKS-96S 57
Gamma BDMG-96 57
EXTERNAL PROBES GAMMA
Gamma-search BDVG-96 58
Gamma-search BDPG-96 58
ContentsRadiation monitoring systemldquoPELIKANrdquo Radiation monitoring system (RMS) 6
BDMG-101 high range gamma area monitor 10
DBG-S11D wide range gamma area monitor 11
BDRG-52 high range gamma area monitor for accident and post-accident conditions 12
UDGP-01 Liquid technological environments monitor 13
UDMN-100 neutron area monitor 14
UDKG-100 Wel Liquid gamma monitor 14
BOP-1M data processing and transmission unit 15
UDA-1AB particulate monitor 16
UDG-1B noble gas monitor 17
UDG-03D noble gas monitor 18
UDI-1B iodine monitor 19
UDGB-01 noble gasesH-3C-14 monitor 20
UDGP-01 steam generator leakage monitor 21
UPPVM air flow parameters monitor 22
ldquoIMPULSrdquo external display unit 23
BI-2 remote display amp alarm unit 24
BASBAS-1s external alarm 25
SKGAV stack monitor 26
RMS software 28
RMS workstation ndash operator console 29
Configurator software 29
RM RACK radiation monitoring rack 30
SRKS-01D criticality accident alarm system 32
ldquoATLANT-Mrdquo environmental radiation monitoring system 34
ldquoBREEZErdquo high-volume air sampler 35
ldquoGAMMA-SENSORrdquo gamma-survey system 36
Radiation monitoring equipmentAREA MONITOR ldquoFREGATrdquo 38
BPI-1D local display unit 39
80
Gamma-search BDPG-96M 58
Gamma BDKG-96 stainless steel casing for geologic applications well logging 59
EXTERNAL PROBES NEUTRON
Neutron BDMN-96 59
Neutron-search BDKN-96 59
RZB-05D Hand-foot-clothing monitor 60
RZBA-04-04M whole body contamination monitor 61
RZA-05D alpha hand-monitor 62
UMF-2000 low level alpha- beta- counter 63
DRK dose area product meter 64
ldquoPROGRESS-BETArdquo scintillation beta spectrometer 65
ldquoPROGRESS-GAMMArdquo scintillation gamma spectrometer 66
ldquoPROGRESS-G(P)rdquo portable scintillation gamma spectrometer 67
ldquoPROGRESS-ARrdquo alpha radiometer 68
ldquoPROGRESSrdquo whole body counter 69
MKG-01D ldquoSADOVNIKrdquo spectrometry system 70
MKS-01A ldquoMULTIRAD-ASrdquo alpha spectrometer 71
UCRV-2 airflow monitor 72
PVP-06 portable air sampler 73
ldquoALPHARAD PLUSrdquo radon thoron amp their progeny monitor 74
UPG-P desktop gamma beam irradiator 75
UPGD-2M-D gamma beam irradiator 76
UKPN-2M-D neutron beam irradiator 77
SPC ldquoDozardquoRadiation monitoring equipment
48 49
Dosimeters DVG-03D
DVGI-8D NEW PEN-TYPE PERSONAL IONIZATION CHAMBER DOSIMETERS
Measurement of personal dose equivalent Hp(10) of gamma and X-ray radiationbull Hp(10) of continuous and pulsed gamma and
X-ray radiation bull Electronic reader KSU-1bull Dosimeter DVG-03D with electronic ID bull Personal dose histories in the readerrsquos memorybull Readerrsquos connection with PC for database main-
tenance
Physical characteristicsDetector bull Ionization chamber
Measurement range bull 001 mSv divide 25 mSv
Energy range bull 0015 divide 25 MeV
Temperature range bull Reader KSU-1 +10 divide +50 ordmСbull Dosimeter DVG-03D minus 40 divide +50 ordmС
Electrical characteristicsPower supply bull Reader KSU-1 220 V 50 Hz built-in batteries bull Dosimeter DVG-03D four batteries CR 1025 bull Batteries life 3 yearsbull Readers interfaces RS-232USB 20
Mechanical characteristicsOverall dimensions weightbull Dosimeter DVG-03D Oslash 18times126 mm 005 kgbull Reader KSU-1 235times232times125 mm 28 kg
Reference standards Nuclear IEC 62387-1
DKG-02U ldquoARBITERrdquo WIDE RANGE GAMMA-DOSIMETER
Physical characteristicsDetectors bull GM counters
Measurement rangebull Dose-rate 01 μSvh divide 3 Svhbull Dose 1 μSv divide 100 Sv
Energy range bull 005 divide 3 MeV
Electrical characteristicsbull Power supply 2 alcaline batteries (type AA)bull Batteries life not less 200 hours
Mechanical characteristicsOverall dimensions weight bull 152times82times32 mm 03 kg
Environmental characteristicsbull Temperature range minus 20 divide +50 ordmCbull Humidity up to 90 at +25 ordmCbull Shock vibration and drop resistant
Reference standards Nuclear IEC 60846
Measurement of gamma radiation ambient equiva-lent dose H(10) and dose rate H(10)bull Audible signals (clicks) for radiation condition
estimationbull Analog scale for search modebull Audible and visual alarms of the excess of preset
dose and dose rate thresholds bull Shock-resistant water-proof easy decontamina-
tion casebull 100 measurement results memory with date and
time of measurementbull Indication of total dose accumulated during
exploitation time bull Indication of measurement result statistical
uncertainty
SPC ldquoDozardquoRadiation monitoring equipment
50 51
Physical characteristicsDetectors bull GM counter
Measurement rangebull Dose-rate 01 μSvh divide 3 mSvhbull Dose 1 μSv divide 02 Sv
Energy range bull 005 divide 3 MeV
Temperature range bull Minus 20 divide +50 ordmC
Electrical characteristicsbull Power supply 2 alcaline batteries 15 V (type AA)bull Batteries life not less 200 hours
Mechanical characteristicsOverall dimensions weight bull 122times74times29 mm 025 kg
Reference standards Nuclear IEC 60846
DKG-07D ldquoDROZDrdquoGAMMA-DOSIMETER
Measurement of gamma radiation ambient equiva-lent dose H(10) and dose rate H(10)bull Two independent measurement channels dose
and dose ratebull Audible signals (clicks) for radiation condition
estimationbull Continuous measurement with updating meas-
urement resultbull Measurement result can be obtained with any
desired statistical uncertainty (error)bull Automatic restart when radiation level sharply
changesbull Indication of statistical uncertainty (error) during
measurement process
Continuous measurement with updating measure-ment result
Automatic restart when radiation level sharply changes bull Gamma dose H(10) and dose-rate H(10) meas-
urementbull Beta and gamma contamination surveybull Indication of statistical uncertainty during the
measurementbull Continuous measurement with accuracy increas-
ing with time bull Automatic restart triggered by change of gamma
dose-ratebull Compensation of gamma count rate while meas-
uring beta radiationbull Indication of battery charge levelbull Audible signal of the excess of preset threshold
Physical characteristicsDetectors bull GM counter
Measurement range bull Dose-rate 01 microSvh divide 20 mSvhbull Dose 1 microSv divide 100 Svbull Beta flux density (for Sr-90+Y-90)
10 divide 105 cm-2 min-1
Energy range bull Gamma 005 divide 3 MeVbull Beta 01 divide 3 MeV
Temperature range bull Minus 20 divide +50 ordmC
MKS-15D ldquoSnegirrdquo backside
MKS-15D ldquoSNEGIRrdquoMULTI ndash PURPOSE RADIATION SURVEY METER
Reference standards Nuclear IEC 60846 IEC 60325
Electrical characteristicsbull Power supply 2 alcaline batteries (type AA)bull Battery life not less 400 hours
Mechanical characteristicsOverall dimensions weight bull 124times72times35 mm 035 kg
SPC ldquoDozardquoRadiation monitoring equipment
52 53
Physical characteristicsDetectorbull GM counter
Measurement range bull 01 μSvh divide 20 mSvh
Energy range bull 005 divide 30 MeV
Threshold setting range bull 03 μSvh divide 20 mSvh
Step change of the thresholdbull In the range 03 divide 10 μSvh with the step
001 μSvhbull In the range 10 divide 100 μSvh with the step
01 μSvhbull In the range 100 divide 2000 μSvh with the step
10 μSvh
Electrical characteristicsPower supply bull 220 V 50 Hz bull Relay output
Mechanical characteristicsProtection index bull IP 40
Overall dimensions weight bull 226times120times75 mm 07 kg
Alarmbull Sound alarm 80 divide 100 dBA at distance 1 mbull Visual alarm redbull Connection of the external alarm signaling unit
Reference standards Nuclear IEC 60846 IEC 60532
Continuous automatic monitoring of the ambient dose equivalent rate bull Measurement of gamma dose rate H(10)bull Audible and visual alarm signals for preset
thresholdsbull Switching on the external signaling or executive
devices
SRPS-05D GAMMA MONITOR
Measurement ofbull Gamma and X-ray personal dose equivalent
Hp(10)bull Neutron personal dose equivalent Hp(10)bull Lens dose equivalent Hp(3)bull Skin dose equivalent Hp(007)bull TLD reader day-to-day tests using built-in LEDbull No needs nitrogen for heating
Physical charachteristicsDetectors bull 7LiF Mg Ti (gamma beta)bull 6LiF Mg Ti (neutron)
Gamma and X-ray Hp(10) Measurement range bull 500 μSv divide 10 Sv
Energy range bull 0015 divide 30 MeV
Neutron Hp(10)Measurement range bull 01 mSv divide 100 mSv
Energy range bull 0025 eV divide 10 MeV
Beta and photons Hp(007) Hp(3) Measurement range bull 2 mSv divide 100 Sv
Energy range bull Beta 025 divide 35 MeVbull Photons lt15 keV
Mechanical characteristicsDosimeters overall dimensions weight bull Gamma Hp(10) DTL-2 holder - 62times26times16 mm
16 gbull DTU holder - 42times28times18 mm 8 gbull Lens Hp(3) face skin Hp(007) Oslash 32times16 mm 9 gbull Finger skin Hp(007) 90times20times2 mm 1 gbull Neutron gamma Hp(10) 48times40times20 mm 30 g
Reference standards Nuclear IEC 61066
DTL-2 DTU-2
MKD (A-type) DVNG-M
DOZA-TLD MULTIPURPOSE TLD SYSTEM
SPC ldquoDozardquoRadiation monitoring equipment
54 55
Continuous and pulsed gamma and X-ray dose H(10) and dose-rate measurementbull Alpha beta and gamma contamination surveybull Neutron dose H(10) and dose-rate measurementbull Gamma radiation flux density in boreholes and
liquid media measurement
Electrical characteristicsPower supply bull UIK-05 four C-size batteriesbull UIK-05-01 rechargeable batterybull UIK-06 rechargeable battery
Interfaces bull RS-232bull USB (via adapter)
bull Detector type automatic determination and corre-sponding measurement modes selection
bull Alarm threshold settings ndash for dose dose-rate alpha and beta contaminations
bull ldquoDetectrdquo and ldquoLocaterdquo modes for survey probes
Reference standards Nuclear IEC 60846 IEC 60325 IEC 61005 IEC 62363
Case
UIK-06 control unit165times78times48 mm 03 kg
DKS-96UNIVERSAL RADIATION SURVEY METER
UIK-05 control unit202times86times90 mm 10 kg
BDZA-96
BDZA-96B
BDZA-96M
BDZA-96S
BDZA-96T
EXTERNAL PROBES ALPHAALPHA BDZA-96Detector bull ZnS(Ag) 70 cm2
Measurement range (for Pu-239)bull 01 divide 104 min-1cm-2
Overall dimensions weightbull Oslash 130times240 mm 11 kg
ALPHA BDZA-96BDetector bull ZnS(Ag) 300 сm2
Measurement range (for Pu-239)bull 01 divide 2103 min-1cm-2
Overall dimensions weightbull Oslash 230times290 mm 40 kg
ALPHA BDZA-96MDetector bull ZnS(Ag) 10 сm2
Measurement range (for Pu-239)bull 01 divide 105 min-1cm-2
Overall dimensions weightbull Oslash 65times240 mm 09 kg
ALPHA BDZA-96SDetector bull ZnS(Ag) 30 сm2
Measurement range (for Pu-239)bull 01 divide 5104 min-1cm-2
Overall dimensions weightbull Oslash 90times240 mm 10 kg
ALPHA BDZA-96TDetector bull Silicon 5 сm2
Measurement range (for Pu-239)bull 01 divide 106 min-1cm-2
Overall dimensions weightbull Oslash 50times60 mm 015 kg
SPC ldquoDozardquoRadiation monitoring equipment
56 57
BETA BDZB-96Detector Scintillator 28 сm2
Measurement range (for Sr-90+Y-90)bull 10 divide 105 min-1cm-2
Energy rangebull 03 divide 30 MeV
Overall dimensions weightbull Oslash 90times230 mm 09 kg
BETA BDZB-99Detector bull GM counter 30 сm2
Measurement range (for Sr-90+Y-90)bull 20 divide 104 min-1см-2
Energy rangebull 012 divide 30 MeV
Overall dimensions weightbull Oslash 88times80 mm 04 kgbull Telescopic pole length 07 m
BETA BDZB-96BDetector bull GM counter 80 сm2
Measurement range (for Sr-90+Y-90)bull 3 divide 104 min-1сm-2
Energy rangebull 012 divide 30 MeV
Overall dimensions weightbull 150times200times110 mm 15 kg
BETA BDZB-96Sbull Detector GM counter 15 сm2
Measurement range (for Sr-90+Y-90)bull 10 divide 3104 min-1cm-2
Energy rangebull 012 divide 30 MeV
Overall dimensions weightbull Oslash 65times65 mm 03 kgbull Telescopic pole length 07 m
BDZB-96
BDZB-99
BDZB-96B
BDZB-96S
EXTERNAL PROBES BETA
GAMMA BDKS-96BDetector bull Tissue-equivalent scintillator Oslash 45times20 mm
Measurement rangebull Dose rate H(10) 01 μSvh divide 1 Svhbull Dose H(10) 01 μSv divide 10 Sv
Energy rangebull 0015 divide 10 MeV
Overall dimensions weightbull Oslash 60times250 mm 085 kg
GAMMA AND BETA BDKS-96SDetector bull Double GM counters
Measurement rangebull Gamma dose rate H(10) 01 μSvh divide 1 mSvhbull Gamma dose H(10) 01 μSv divide 10 Svbull Beta 10 divide 3104 min-1cm-2
Energy rangebull Gamma 005 divide 3 MeVbull Beta 012 divide 3 MeV
Overall dimensions weightbull Oslash 80times80 mm 035 kgbull Telescopic pole length 07 m
GAMMA BDMG-96Detector bull GM counters
Measurement rangebull Dose rate H(10) 01 μSvh divide 10 Svhbull Dose H(10) 01 μSv divide 10 Sv
Energy range bull 005 divide 3 MeV
Overall dimensions weightbull 40times250 mm 05 kgbull Telescopic pole length 07 m 4 m (by request)
EXTERNAL PROBES GAMMA
BDKS-96B
BDMG-96
BDKS-96S
SPC ldquoDozardquoRadiation monitoring equipment
58 59
GAMMA-SEARCH BDVG-96Detector bull Scintillator NaI(Tl) Oslash 63times63 mm
Measurement rangebull Flux density measurement range 4 divide 2000 s-1cm-2
bull Dose rate H(10) for Cs-137 01 divide 30 μSvhbull Sensitivity for Cs-137 3000 (pulsess-1)( μSvh-1)
Overall dimensions weightbull Oslash 88times400 mm 20 kgbull Modular pole length 16 m
GAMMA-SEARCH BDPG-96Detector bull Scintillator NaI(Tl) Oslash 25times40 mm
Measurement rangebull Flux density measurement range 10 divide 8000 s-1cm-2
bull Dose rate H(10) for Cs-137 01 divide 100 μSvhbull Sensitivity for Cs-137 500 (pulsess-1)( μSvh-1)
Overall dimensions weightbull 50times190times480 mm 10 kgbull Telescopic pole length 07 m
GAMMA-SEARCH BDPG-96MDetector bull Scintillator NaI(Tl) Oslash 18times30 mm
Measurement rangebull Flux density measurement range 10 divide 24000 s-1cm-2
bull Dose rate H(10) for Cs-137 01 divide 300 μSvhbull Sensitivity for Cs-137 200 (pulsess-1)( μSvh-1)
Overall dimensions weightbull Oslash 35times320 mm 05 kgbull Telescopic pole length 07 or 38 m
EXTERNAL PROBES GAMMA
BDVG-96
BDPG-96M
BDPG-96
EXTERNAL PROBESGAMMA BDKG-96 STAINLESS STEEL CASING FOR GEOLOGIC APPLICATIONS WELL LOGGINGDetector bull Scintillator NaI(Tl) Oslash 18times30 mm
Measurement rangebull Flux density measurement range 10 divide 105 s-1cm-2
bull Dose rate H(10) for Cs-137 5 divide 2104 μRhbull Sensitivity for Cs-137 200 (pulsess-1)( μSvh-1)
Overall dimensions weightbull Oslash 38times535 mm 36 kgbull Cable length 10 divide 1000 m
NEUTRON BDMN-96Detector bull Scintillator with ZnS(Ag)
Measurement rangebull Dose rate H(10) 01 μSvh divide 01 Svhbull Dose H(10) 01 μSv divide 10 Sv
Energy range bull 0025 eV divide 10 MeV
Overall dimensions weightbull Detector Oslash 54times200 mm 08 kgbull Moderator Oslash 245 mm 73 kg
NEUTRON-SEARCH BDKN-96Detector bull He-3 counter in polyethilene moderator
Measurement rangebull Dose rate H(10) for Pu-Be 01 μSvh divide 01 Svhbull Dose H(10) for Pu-Be 01 μSv divide 10 Sv
Energy range bull 0025 eV divide 14 MeV
Overall dimensions weightbull 295times142times100 mm 225 kg
BDKG-96M
BDMN-96
BDKN-96
SPC ldquoDozardquoRadiation monitoring equipment
60 61
bull No gas supply neededbull Clothing control detachable right hand detector bull Alpha detector optional connection bull Numeric and color (red green) indication of
control resultsbull LED sensor of hand-foot positioning for start of
measurementbull Automatic compensation of gamma background
and contamination of detectorbull Audible alarm signals of the excess of preset
thresholdsbull Measurement value indication min-1cm-2 or
Bqсm2
Reference standards Nuclear IEC 61098
RZB-05D HAND-FOOT-CLOTHING MONITOR
Physical characteristicsDetectors bull Gamma beta - GM countersbull Alpha - scintillatior ZnS(Ag)
Detecting nuclidesbull Alpha Pu-239 U-234 U-238bull Beta Sr-90+Y-90 F-18 Cs-137 Co-60 Tс-99 O-15
N-13 Sr-89 C-11 I-131 Na-22 Ru-106+Rh-106 Tl-204
bull Gamma Tc-99m I-123
Efficiencybull Alpha
Pu-239 40 U-234 25U-238 15
bull Beta Sr-90 +Y-90 40
Measurement range bull Alpha 1 divide 103 min-1cm-2 bull Beta 10 divide 103 min-1cm-2
bull Gamma 5103 divide 5106 min-1cm-2
Energy range bull Alpha 30 divide 80 MeV bull Beta 008 divide 35 MeV bull Gamma 005 divide 30 MeV
Operation temperature range bull Minus 10 divide +50 ordmС
Electrical characteristicsbull Power supply 220 V 50 Hz
Mechanical characteristicsOverall dimensions weight bull 740times750times1180 mm 45 kg
Versionsbull Withwithout alpha detectorbull Indication (min-1cm-2 ) or (Bqсm2)bull Detectors overall dimensions smbull Hand 178 х 235bull Foot 185 х 436
Whole body contamination monitor RZBA-04-04Mbull No gas supply neededbull Compensation for background gamma radiation
and contamination of detector unitsbull Individual threshold setting for each measure-
ment channelbull Visible and audible alarms ldquoCONTAMINATIONrdquo and
ldquoCLEANrdquo bull Indication of contaminated body parts on the
panel with image of the bodybull Optional remote alpha-detector
Physical characteristicsDetectors bull Beta - GM counters scintillatorsbull Alpha - scintillatior ZnS(Ag)
Measurement range bull Beta 5 divide 15000 min-1cm-2
bull Alpha 01 divide 10000 min-1cm-2
Energy range bull Beta 015 divide 25 MeV bull Alpha 40 divide 56 MeV
Operation temperature range bull +5 divide +50 ordmС
Electrical characteristicsPower supply bull 220 V 50 Hz
Interfaces bull RS-232bull RS-485
Mechanical characteristicsOverall dimensions weight bull 2650times940times930 mm 310 kg
Versionsbull Withwithout alpha detectorbull Indication (min-1cm-2 ) or (Bqсm2)
Reference standards Nuclear IEC 61098
RZBA-04-04MWHOLE BODY CONTAMINATION MONITOR
SPC ldquoDozardquoRadiation monitoring equipment
62 63
RZA-05DALPHA HAND-MONITOR
bull No gas supply needed bull Numeric and color (red green) indication of
control resultsbull LED sensor of hand- positioning for start of
measurementbull Audible alarm signals of the excess of preset
thresholdsbull Measurement value indication min-1cm-2 or
Bqсm2
Physical characteristicsDetectors alpha - scintillatior ZnS(Ag)
Efficiencybull Pu-239 20 bull U-234 14bull U-238 8
Measurement range bull 05 divide 105 min-1cm-2
Energy range bull 41 divide 90 MeV
Operation temperature range bull minus 10 divide +50 ordmС
Electrical characteristicsPower supply bull 220 V 50 Hz
Mechanical characteristicsOverall dimensions weight no more bull 740times1400times1450 mm 70 kg
Reference standards Nuclear IEC 61098
bull Simultaneous measurement of alphabeta activi-ties in the sample
bull Active shielding anti-coincidence background subtraction using GM counters
bull Lead shielding 30 mm
UMF-2000 LOW LEVEL ALPHA- BETA- COUNTER
Physical characteristicsDetectors bull Silicon specrometric detector 500 or 1000 mm2
Measurement range bull Alpha 001 divide 1000 Bq bull Beta 01 divide 3000 Bq
Energy range bull Alpha 35 divide 80 MeV bull Beta 005 divide 35 MeV
Electrical characteristicsPower supply bull 220 V 50 Hz
Interfaces bull RS-232bull USB
Mechanical characteristicsOverall dimensions weight bull 337times286times190 mm 22 kg
Versionsbull Detector area 500 mm2
bull Detector area 1000 mm2
UMF-2000 Detector area 1000 mm2
UMF-2000 Detector area 500 mm2
SpectraDec software for alpha-spectrometric measurements
SPC ldquoDozardquoRadiation monitoring equipment
64 65
DRK DOSE AREA PRODUCT METER
DRK-1bull Diagnostic reference level (DRL) of patients
determinationbull Suitable for all basic types of x-ray machines
Physical characteristicsDetector bull Plane-parallel ionization chamber
Measurement range bull 1 divide 104 cGycm2
Electrical characteristicsPower supply bull 220 V 50 Hz
DRK-1M-CTbull Measuring of dose length product
Physical characteristicsDetector bull Pencil Ionization Chamber
Measurement rangebull 05 divide 109 microGym
DRK-1Mbull Measuring of air kerma on sectional area of the
X-ray beam productbull Measuring of air kerma rate on area productbull Measuring of air kerma ratebull Measuring of air kerma
Physical characteristicsDetector bull Plane-parallel ionization chamber
Measurement rangebull 01 divide 109 microGym2
bull 06 divide 6104 microGym2cbull 30 divide 9105 microGycbull 30 divide 9991011 microGyReference standard IEC 60580 2003
bull Measurement of strontium-90 in the foodstuffs agricultural products etc
bull Measurement of gross beta activity in samplebull Self tests using built-in LED
ldquoPROGRESS-BETArdquo SCINTILLATION BETA SPECTROMETER
Physical characteristicsDetector bull Plastic scintillator Oslash70x10 mm
Sample bull Plate Oslash70 mmbull Weight up to 15 g
Energy range bull 02 divide 30 MeV
Minimum detectable activity of Sr-90 in a 10 g sample on a standard planchet Bqsamplebull In case of absence of K-40 in the sample 01 Bqbull In case the activity of K-40 till 5 Bqg 05 Bq
Electrical characteristics Interface bull USB
Mechanical characteristicsWeight bull No more 50 kg
Complete setBasic complete setbull Detector unit with plastic scintillator integrated
power supply amplifier ADC bull Lead shielding bull ldquoProgressrdquo software bull Сheck source for energetic calibration (Sr-90-Y-90) bull Planchet Oslash 70 mm (5 items) bull Sample dencification device bull Procedure manual for measurement of radio-
nuclidesrsquo activity using the scintillation beta spec-trometer ldquoProgressrdquo
Optional equipment and servicebull Personal computer and printer bull Calibrations for radionuclides not included in the
main library of radionuclides
Progress-Beta
Reference standards IEC 61562
SPC ldquoDozardquoRadiation monitoring equipment
66 67
bull Measurement of gamma activity in foodstuffs soil samples and others environmental objects
bull Identification of radionuclides in the sample bull Automatic correction for sample density bull Self-tests using built-in LED
ldquoPROGRESS-GAMMArdquoSCINTILLATION GAMMA SPECTROMETER
Physical characteristicsDetector bull NaI (Tl) Oslash63times63 mm
Validated measurement geometries bull Marinelli beakers (1 liter) Petri dishes (Oslash90 mm)
etc
Energy range bull 02 divide 30 MeV
Minimum detectable activity Bqsamplebull Cs-137 3 Bqbull Th-232 7 Bqbull Ra-226 8 Bq bull К-40 40 Bq
Electrical characteristics Interface bull USB
Mechanical characteristicsWeight bull No more 120 kg
Complete setBasic complete setbull Scintillation detector unit with NaI (Tl) detector
with integrated power supply amplifier and ADC bull Lead shielding 50 mm bull ldquoProgressrdquo software bull Сheck source for energy calibration (Cs-137 +
K-40)bull Marinelli beakers - 1 liter (5 items) bull Petri dishes Oslash 90 mm (5 items) bull Procedure manual for measurement of activity
of radionuclides using the scintillation gamma spectrometer ldquoProgressrdquo
Optional equipment and servicebull Kit for radon measurements including calibration
of ldquoIC-63rdquo geometry for counting the charcoal samples
bull Personal computer and printer bull Calibrations for user defined geometries bull Calibrations for radionuclides not included in the
main library of radionuclides
Progress-Gamma
Reference standards IEC 61563
ldquoPROGRESS-G(P)rdquoPORTABLE SCINTILLATION GAMMA SPECTROMETERbull Field measurements of gamma activity in environ-
mental objects without sampling (4π geometry)bull Laboratory measurement of gamma activity in
foodstuffs soil samples and others environmental objects
bull Identification of radionuclides in the sample bull Automatic correction for sample densitybull Tests using built-in LED
Physical charachteristicsDetector bull NaI (Tl) Oslash45times50 mmbull Lead shielding 20 mm
Validated measurement geometries bull Marinelli beakers (05 liter) Petri dishes (Oslash90 mm)
etc
Energy range bull 02 divide 30 MeV
Minimum detectable activity in 05-litre Marinelli beaker bull Cs-13710 Bqkgbull К-40100 Bqkgbull Ra-22618 Bqkg bull Th-23216 Bqkg
Minimum detectable activity in 30 min (4π geometry) bull Cs-137 2 Bqkgbull К-40 30 Bqkgbull Ra-226 4 Bqkg bull Th-232 3 Bqkg
Electrical characteristicsPower supply bull Rechargeable batterybull 220 V 50 Hz
Interface bull USB RS-232
Weight bull No more than 60 kg
Complete setBasic complete setbull Scinttillation detector unit with NaI(Tl) bull ldquoProgressrdquo softwarebull Сontrol unit ldquoSputnikrdquo for aquisition and analisys
of spectra with built-in memory for spectral databull Casebull Lead shielding (2 cm) for laboratory usebull 05-litre Marinelli beakers ndash 5 itemsbull Na-22 check sourcebull Power adapter BPS-01bull Operation manualbull Procedure manual for measurement of activity
of radionuclides using the scintillation gamma spectrometer ldquoProgressrdquo
Optional equipment and servicebull Kit for radon measurements with charcoalbull Built-in dose rate meterbull Additional memory (RAM) for storage of 64
spectrabull Additional power adapterbull Notebook and printer
Progress-Gamma
Reference standards IEC 61563
SPC ldquoDozardquoRadiation monitoring equipment
68 69
Physical characteristicsDetectorbull Scintillation detector ZnS (Oslash 60 mm)
Samplebull Thin sample - diameter up to 70 mm bull Preparation technique - electro-depositionbull Thick sample - diameter 70 mm weight
200300 mg bull Preparation technique - application of powders
(prepared by radiochemical concentration by water evaporation or by pounding of mineral samples) onto a planchet with the help of spirit
Energy rangebull 15 divide 8 MeV
Minimum detectable activitybull Thin samples no more than 910-3 Bqsamplebull Thick samples no more than 180 Bqkg
Mechanical characteristicsOverall dimensions weightbull 195times120times210 mm 34 kg
Complete setBasic complete setbull Alpha radiometer ldquoProgress-ARrdquobull Check source (uranium isotopes)
Set of accessoriesbull Procedure manual for measurements of radi-
oactivity using scintillation alpha radiometer ldquoProgress-ARrdquo
bull ldquoProgressrdquo software
ldquoProgress-ARrdquo
bull Measurement of gross activity of alpha emitting radionuclides in thin samples
bull Measurement of gross activity of alpha emitting radionuclides in thick samples
bull Measurement of activity deposited on aerosol filters
ldquoPROGRESS-ARrdquoALPHA RADIOMETER
Several fixed positions of the detector enable to perform measurements in various geometries and to estimate the content ofbull Cs-137 in the whole bodybull I-131 in thyroidbull Co-60 Cs-137 Mn-54 Cr-51 in lungsbull Database for storage of measurement data and
resultsbull Uncertainty calculations based on measurement
databull Self tests using built-in LED
ldquoPROGRESSrdquo WHOLE BODY COUNTER
Physical characteristicsDetectorbull scintillation detector NaI (Tl) Oslash63times63 mm
Energy rangebull 02 divide 28 MeV
Minimum detectable activitybull By Cs-137 in the whole body - 1200 Bqbull By I-131 in thyroid - 100 Bqbull By Co-60 Cs-137 Mn-54 Cr-51 in lungs - 200 Bq
Mechanical characteristicsWeight bull No more than 120 kg
Complete setBasic complete setbull Collimator with rotator and holderbull Detector with incorporated ADCbull Patient chair and table for collimatorbull Check source Na-22bull Procedure manual for lifetime measurement of
gamma-emitting radionuclidesrsquo activity in human body using the gamma-spectrometer of human radiation ldquoProgressrdquo
bull laquoProgressraquo software
Optional equipment and servicebull Program of internal radiation committed internal
radiation effective dose calculation by the stand-ard model
bull Background phantombull Personal computer and printer
Collimator with rotator and holder
SPC ldquoDozardquoRadiation monitoring equipment
70 71
bull Categorization of wastes for the purpose of fur-ther processing including wastes with unknown radionuclide composition
bull Measurements during the incoming waste inspec-tion (accepting for storage disposal)
bull Certification of unconditioned and conditioned wastes in closed containers without opening them (at nuclear plants or at facilities providing collection storage transportation conditioning processing temporal storage and final disposal of radioactive waste)
bull Activity measurement of extended objects in situ without opening the equipment
bull Activity measurement of extended objects after opening (for example assessment of tubes used for oil transportation)
MKG-01D ldquoSADOVNIKrdquoSPECTROMETRY SYSTEM
Physical charachteristicsDetectorbull Detector unit GEM (GMX) with HPGe detector and
multi-positioning cryostat CFG-PMOD4-7 with 7 litre Dewar
bull Dose rate probe BDMG-200
Energy range bull With GEM detector 004 divide 30 MeVbull With GMX detector 0005 divide 15 MeVbull Dose rate probe BDMG-200 ndash 005 divide 30 MeV
Measurement rangebull 110-7 divide 10 Svhbull Relative efficiency of detection (in photopeak) at
13325 MeV (Co-60) 10 divide 150
Electrical characteristicsPower supplybull 220 V 50 Hz
Interfacebull USB
Complete setBasic complete setbull Spectrometric detector unit GEM (GMX) with
HPGe detector and multi-positioning cryostat with 7 litre Dewar
bull Portable digital multichannel analyzer DigiDARTbull Dose rate probe BDMG-200bull Autonomous power supply unit with built-in
batterybull Industrial computer keyboardbull Laser range-finderbull Thermographic printerbull Web-camerabull Device equipped with stepper motor for position-
ing of the spectrometric detectorbull Calibration device with reference sources
(Am-241 Co-60 Ba-133 Eu-152) for energy calibration
bull Removable collimators with end capbull Measurement proceduresbull ldquoClasterrdquo software
bull Measurement of gross alpha activity of alpha-emitting radionuclides
bull Measurement of alpha-emitting radionuclides activity in thin-layer samples meeting alpha-spectrometry requirements
Physical characteristicsDetectorbull Silicon ion-implanted 450 mm2
bull Easy to decontaminate thin windowbull dead layer less than 015 μmbull Background count rate in the range 3 divide 9 MeVbull No more than 09 h-1cm-2 for 450 mm2 detector
Energy rangebull 2 divide 9 MeVbull Lower limit of measurement range (minimum
detectable activity) 01 Bqbull Background count rate no more than 100 counts
in 24 hours
Electrical characteristics Power supplybull 220 V 50 Hz
Interfacebull USB
Complete setBasic complete setbull Detector unit with vacuum measuring chamber
and vacuum control systembull Low noise vacuum pump (type 2FY-05B or
equivalent)bull Check sourcebull ldquoProgressrdquo softwarebull Vacuum tube
MKS-01A ldquoMULTIRAD-ASrdquoALPHA SPECTROMETER
SPC ldquoDozardquoRadiation monitoring equipment
72 73
UCRV-2AIRFLOW MONITOR
bull Monitor of the air flow through filter of centralized multichannel sampling system
bull Radiation monitoring system (RMS) integration for internal exposures determination
bull Volume and flow rate measurements of the air that have passed through a analytical filter
bull Bar-code for filter identificationbull Operation as either standalone unit or as a part of
the RMS
Physical characteristicsMeasurement range of air volume bull 001 divide 9999 m3
Operation temperature range bull minus 20 divide +50 ordmС
Electrical characteristicsPower supply bull 220 V 50 Hz
Interface bull RS-485
PVP-06PORTABLE AIR SAMPLER
Air Sampler PVP-06 is indispensable for monitoring the radiation situation where the concentration of radioactive aerosols in the air does not require a sta-tionary sampling equipment Sampling head PVP-06 provides easy change of filters and cartridges
Purposebull To monitor the concentration of radioactive aero-
sols in the air sites
Controlled aerosolsbull Alpha- and beta-active aerosolsbull Daughter products of decay of radon and thoronbull Iodine isotopes
Physical characteristicsTypes of filtersbull Aerosol AFA-RSP-20bull Iodine AFA SI-20
Flow rate bull 33∙10-4 ndash 233∙10-4 m3s (20 divide 140 l min)
Electrical characteristicsPower supply bull 220 V50 Hzbull The vehicle power supply 108 divide 145 Vbull Internal battery
Minimal working time on internal battery to recharge bull 8 hours
Power consumption (at a flow rate of 100 lmin) bull 40 VA
Environment characteristicsOperating temperature bull minus 10 divide +40 deg C
Maximum humidity bull 90
Pressure bull 860 to 1060 hPA
Noise generated by the pump bull lt 55 dBA at 1 m
Mechanical characteristicsDimensions weight bull 241 times 108 times 160 mm 28 kg
Case material bull Plastic
Complete setbull Air sampler PVP-06bull AC power adapterbull Filters AFA-RSP-20 - 100 pcsbull Packaging for filters - 40 pcsbull Casebull Operation manualbull Calibration certificate
Optional equimpient bull Kit for sampling sorption columns of activated
carbon Ř head of sorption columns with protective
covers Ř activated charcoal SKT-3 - 1 pkg (02 L) Ř charocoal samples SC-13 - 8 pcs
bull Car charger bull Tipod bull Shoulder strapbull Calibration stand bull Filters AFA SI-20 - 100 pcs
Consumablesbull Aerosol filters AFA RSP-20bull Iodine filters AFA SI-20
SPC ldquoDozardquoRadiation monitoring equipment
74 75
Calibration of gamma dose and dose rate meters
Calibration ofbull Ambient equivalent dose H(10) meters (Sv Svh)bull Personal equivalent dose Hp(10) meters (Sv Svh)bull Exposure dose X meters (R Rh)bull Two sources in irradiator bull Select source and collimator opening using
tumbler
UPG-P DESKTOP GAMMA BEAM IRRADIATOR
Physical characteristicsRange of reproduced dose rate bull 05 μSvh divide 10 mSvh (50 μRh divide 100 mRh)
Sources activities bull 6times106 6times108 Bq (02 20 mCi) Cs-137
Overall dimensions bull 1250times400times300 mm
Irradiator weight bull Not more than 37 kg
Calibration bench weight bull Not more than 15 kg
Reference standards IEC 60846 IEC 61526
Physical characteristicsDetectorbull Silicon
Measurement range EEC measurement bull Measurement range of radon EEC
10 divide 10bull106 Bqbullm-3
bull Measurement range of thoron EEC 05 divide 10bull104 Bqbullm-3
bull Air flow through the filter 100plusmn05 lmin
Concentration measurementbull Measurement range of radon-222 concentration
in air 10 divide 20bull106 cpsbull Measurement range of 216Po(ThA)
1bull10-3 divide 1bull102 cpsbull Air sampler flow rate
10plusmn02 lminbull Measurement range of radon-222 concentration
in water samples 6 divide 800 Bqbullkg-1
bull Measurement range of radon-222 flux from soil surface 20 divide 103 mBqsbullm2
bull Measurement range of radon-222 concentration with preliminary sampling of air using air sam-plers 20 divide 107 Bqbullm-3
bull Measurement range of radon-222 concentration in samples of soil air 103 divide 106 Bqbullm-3
Operation temperature range bull 1 divide 35 ordmC
Electrical characteristicsPower supply bull 80 VA
Mechanical characteristicsOverall dimensions weight bull 220times200times165 mm 36 kg
ldquoALPHARAD PLUSrdquoRADON THORON amp THEIR PROGENY MONITORbull Measurement of radon and thoron concentration
and effective equivalent concentration (EEC)bull In the airbull In the indoor air of residential public and industri-
al buildings and structuresbull Measurement of radon in drinking water sourcesbull Measurements of radon flux from the soil surface
at land plots allocated for construction of houses public buildings and industrial facilities
bull Measurements of radon concentration in soil air
Reference standards IEC 61577
SPC ldquoDozardquoRadiation monitoring equipment
76 77
UKPN-2M-D NEUTRON BEAM IRRADIATOR
Reference standards IEC 61005 61322
Calibration of neutron dose and dose rate meters
Calibration ofbull Ambient equivalent dose H(10) meters (Sv Svh)bull Personal equivalent dose Hp(10) meters (Sv Svh)bull Flux density of neutrons (cm-2∙s-1)bull Transfer container for temporary storage of
sources bull Red light signal of source working position
Physical carachteristicsRange of reproduced dose ratebull 20 divide 800 μSvh
Range of reproduced flux densitiesbull 10 divide 400 cm-2∙s-1
Type of a source in use bull Pu-Be
Activity of a source in usebull 24х1011 Bq (with density of 107 s-1)
Overall dimensions weight no morebull 3000x750x2000 mm 300 kg
Required room dimensionsbull not less than 7x3x3 m
Electrical characteristicsPower supply bull 220 V 50 Hz
Calibration of gamma dose and dose rate meters
Calibration ofbull Ambient equivalent dose H(10) meters (Sv Svh)bull Personal equivalent dose Hp(10) meters (Sv Svh)bull Exposure dose X meters (R Rh)bull Four sources in irradiator bull Select source and move to working position
return to storage position using special rodbull Transfer container for temporary storage of
sources bull Red light signal of source working position
UPGD-2M-DGAMMA BEAM IRRADIATOR
Physical characteristicsRange of reproduced dose rate bull 05 μSvh divide 50 mSvh (50 μRh divide 5 Rh)
Maximum activity of source bull 2times1011 Bq (50 Ci) Cs-137
Overall dimensionsbull Irradiator 800times500times500 mmbull Guide rails length 30 mbull Height 16 mbull Weight not more than 700 kgbull Required room dimensions not less than 7x3x3 m
Electrical characteristicsPower supply bull 220 V 50 Hz
UPGD-2M-D
Reference standards IEC 60846 IEC 61526 IEC 61066
SPC ldquoDozardquo
78 79
Contents
MEASURING UNITS
DBG-S11D wide range gamma area monitor 40
UDKS-100 gamma and X-ray area monitor 41
UDMN-100 neutron area monitor 41
ALARM UNITS
BAS-2 ldquoMICROrdquo external visual alarm 42
BZS-2 ldquoMicrordquo external audible alarm 42
Illuminated warning signs 43
ldquoImpulsrdquo external display unit 43
UIM-3D area monitor count rate meter 44
DKG-05D personal gamma dosimeter 46
DVS-02D gamma-neutron personal electronic dosimeter 47
DVGI-8D new pen-type personal ionization chamber dosimeters 48
DKG-02U ldquoARBITERrdquo wide range gamma-dosimeter 49
DKG-07D ldquoDROZDrdquo gamma-dosimeter 50
MKS-15D ldquoSNEGIRrdquo multi ndash purpose radiation survey meter 51
SRPS-05D gamma monitor 52
DOZA-TLD multipurpose TLD system 53
DKS-96 universal radiation survey meter 54
EXTERNAL PROBES ALPHA
Alpha BDZA-96 55
Alpha BDZA-96B 55
Alpha BDZA-96M 55
Alpha BDZA-96S 55
Alpha BDZA-96T 55
EXTERNAL PROBES BETA
Beta BDZB-96 56
Beta BDZB-99 56
Beta BDZB-96B 56
Beta BDZB-96S 56
EXTERNAL PROBES GAMMA
Gamma BDKS-96B 57
Gamma and beta BDKS-96S 57
Gamma BDMG-96 57
EXTERNAL PROBES GAMMA
Gamma-search BDVG-96 58
Gamma-search BDPG-96 58
ContentsRadiation monitoring systemldquoPELIKANrdquo Radiation monitoring system (RMS) 6
BDMG-101 high range gamma area monitor 10
DBG-S11D wide range gamma area monitor 11
BDRG-52 high range gamma area monitor for accident and post-accident conditions 12
UDGP-01 Liquid technological environments monitor 13
UDMN-100 neutron area monitor 14
UDKG-100 Wel Liquid gamma monitor 14
BOP-1M data processing and transmission unit 15
UDA-1AB particulate monitor 16
UDG-1B noble gas monitor 17
UDG-03D noble gas monitor 18
UDI-1B iodine monitor 19
UDGB-01 noble gasesH-3C-14 monitor 20
UDGP-01 steam generator leakage monitor 21
UPPVM air flow parameters monitor 22
ldquoIMPULSrdquo external display unit 23
BI-2 remote display amp alarm unit 24
BASBAS-1s external alarm 25
SKGAV stack monitor 26
RMS software 28
RMS workstation ndash operator console 29
Configurator software 29
RM RACK radiation monitoring rack 30
SRKS-01D criticality accident alarm system 32
ldquoATLANT-Mrdquo environmental radiation monitoring system 34
ldquoBREEZErdquo high-volume air sampler 35
ldquoGAMMA-SENSORrdquo gamma-survey system 36
Radiation monitoring equipmentAREA MONITOR ldquoFREGATrdquo 38
BPI-1D local display unit 39
80
Gamma-search BDPG-96M 58
Gamma BDKG-96 stainless steel casing for geologic applications well logging 59
EXTERNAL PROBES NEUTRON
Neutron BDMN-96 59
Neutron-search BDKN-96 59
RZB-05D Hand-foot-clothing monitor 60
RZBA-04-04M whole body contamination monitor 61
RZA-05D alpha hand-monitor 62
UMF-2000 low level alpha- beta- counter 63
DRK dose area product meter 64
ldquoPROGRESS-BETArdquo scintillation beta spectrometer 65
ldquoPROGRESS-GAMMArdquo scintillation gamma spectrometer 66
ldquoPROGRESS-G(P)rdquo portable scintillation gamma spectrometer 67
ldquoPROGRESS-ARrdquo alpha radiometer 68
ldquoPROGRESSrdquo whole body counter 69
MKG-01D ldquoSADOVNIKrdquo spectrometry system 70
MKS-01A ldquoMULTIRAD-ASrdquo alpha spectrometer 71
UCRV-2 airflow monitor 72
PVP-06 portable air sampler 73
ldquoALPHARAD PLUSrdquo radon thoron amp their progeny monitor 74
UPG-P desktop gamma beam irradiator 75
UPGD-2M-D gamma beam irradiator 76
UKPN-2M-D neutron beam irradiator 77
SPC ldquoDozardquoRadiation monitoring equipment
50 51
Physical characteristicsDetectors bull GM counter
Measurement rangebull Dose-rate 01 μSvh divide 3 mSvhbull Dose 1 μSv divide 02 Sv
Energy range bull 005 divide 3 MeV
Temperature range bull Minus 20 divide +50 ordmC
Electrical characteristicsbull Power supply 2 alcaline batteries 15 V (type AA)bull Batteries life not less 200 hours
Mechanical characteristicsOverall dimensions weight bull 122times74times29 mm 025 kg
Reference standards Nuclear IEC 60846
DKG-07D ldquoDROZDrdquoGAMMA-DOSIMETER
Measurement of gamma radiation ambient equiva-lent dose H(10) and dose rate H(10)bull Two independent measurement channels dose
and dose ratebull Audible signals (clicks) for radiation condition
estimationbull Continuous measurement with updating meas-
urement resultbull Measurement result can be obtained with any
desired statistical uncertainty (error)bull Automatic restart when radiation level sharply
changesbull Indication of statistical uncertainty (error) during
measurement process
Continuous measurement with updating measure-ment result
Automatic restart when radiation level sharply changes bull Gamma dose H(10) and dose-rate H(10) meas-
urementbull Beta and gamma contamination surveybull Indication of statistical uncertainty during the
measurementbull Continuous measurement with accuracy increas-
ing with time bull Automatic restart triggered by change of gamma
dose-ratebull Compensation of gamma count rate while meas-
uring beta radiationbull Indication of battery charge levelbull Audible signal of the excess of preset threshold
Physical characteristicsDetectors bull GM counter
Measurement range bull Dose-rate 01 microSvh divide 20 mSvhbull Dose 1 microSv divide 100 Svbull Beta flux density (for Sr-90+Y-90)
10 divide 105 cm-2 min-1
Energy range bull Gamma 005 divide 3 MeVbull Beta 01 divide 3 MeV
Temperature range bull Minus 20 divide +50 ordmC
MKS-15D ldquoSnegirrdquo backside
MKS-15D ldquoSNEGIRrdquoMULTI ndash PURPOSE RADIATION SURVEY METER
Reference standards Nuclear IEC 60846 IEC 60325
Electrical characteristicsbull Power supply 2 alcaline batteries (type AA)bull Battery life not less 400 hours
Mechanical characteristicsOverall dimensions weight bull 124times72times35 mm 035 kg
SPC ldquoDozardquoRadiation monitoring equipment
52 53
Physical characteristicsDetectorbull GM counter
Measurement range bull 01 μSvh divide 20 mSvh
Energy range bull 005 divide 30 MeV
Threshold setting range bull 03 μSvh divide 20 mSvh
Step change of the thresholdbull In the range 03 divide 10 μSvh with the step
001 μSvhbull In the range 10 divide 100 μSvh with the step
01 μSvhbull In the range 100 divide 2000 μSvh with the step
10 μSvh
Electrical characteristicsPower supply bull 220 V 50 Hz bull Relay output
Mechanical characteristicsProtection index bull IP 40
Overall dimensions weight bull 226times120times75 mm 07 kg
Alarmbull Sound alarm 80 divide 100 dBA at distance 1 mbull Visual alarm redbull Connection of the external alarm signaling unit
Reference standards Nuclear IEC 60846 IEC 60532
Continuous automatic monitoring of the ambient dose equivalent rate bull Measurement of gamma dose rate H(10)bull Audible and visual alarm signals for preset
thresholdsbull Switching on the external signaling or executive
devices
SRPS-05D GAMMA MONITOR
Measurement ofbull Gamma and X-ray personal dose equivalent
Hp(10)bull Neutron personal dose equivalent Hp(10)bull Lens dose equivalent Hp(3)bull Skin dose equivalent Hp(007)bull TLD reader day-to-day tests using built-in LEDbull No needs nitrogen for heating
Physical charachteristicsDetectors bull 7LiF Mg Ti (gamma beta)bull 6LiF Mg Ti (neutron)
Gamma and X-ray Hp(10) Measurement range bull 500 μSv divide 10 Sv
Energy range bull 0015 divide 30 MeV
Neutron Hp(10)Measurement range bull 01 mSv divide 100 mSv
Energy range bull 0025 eV divide 10 MeV
Beta and photons Hp(007) Hp(3) Measurement range bull 2 mSv divide 100 Sv
Energy range bull Beta 025 divide 35 MeVbull Photons lt15 keV
Mechanical characteristicsDosimeters overall dimensions weight bull Gamma Hp(10) DTL-2 holder - 62times26times16 mm
16 gbull DTU holder - 42times28times18 mm 8 gbull Lens Hp(3) face skin Hp(007) Oslash 32times16 mm 9 gbull Finger skin Hp(007) 90times20times2 mm 1 gbull Neutron gamma Hp(10) 48times40times20 mm 30 g
Reference standards Nuclear IEC 61066
DTL-2 DTU-2
MKD (A-type) DVNG-M
DOZA-TLD MULTIPURPOSE TLD SYSTEM
SPC ldquoDozardquoRadiation monitoring equipment
54 55
Continuous and pulsed gamma and X-ray dose H(10) and dose-rate measurementbull Alpha beta and gamma contamination surveybull Neutron dose H(10) and dose-rate measurementbull Gamma radiation flux density in boreholes and
liquid media measurement
Electrical characteristicsPower supply bull UIK-05 four C-size batteriesbull UIK-05-01 rechargeable batterybull UIK-06 rechargeable battery
Interfaces bull RS-232bull USB (via adapter)
bull Detector type automatic determination and corre-sponding measurement modes selection
bull Alarm threshold settings ndash for dose dose-rate alpha and beta contaminations
bull ldquoDetectrdquo and ldquoLocaterdquo modes for survey probes
Reference standards Nuclear IEC 60846 IEC 60325 IEC 61005 IEC 62363
Case
UIK-06 control unit165times78times48 mm 03 kg
DKS-96UNIVERSAL RADIATION SURVEY METER
UIK-05 control unit202times86times90 mm 10 kg
BDZA-96
BDZA-96B
BDZA-96M
BDZA-96S
BDZA-96T
EXTERNAL PROBES ALPHAALPHA BDZA-96Detector bull ZnS(Ag) 70 cm2
Measurement range (for Pu-239)bull 01 divide 104 min-1cm-2
Overall dimensions weightbull Oslash 130times240 mm 11 kg
ALPHA BDZA-96BDetector bull ZnS(Ag) 300 сm2
Measurement range (for Pu-239)bull 01 divide 2103 min-1cm-2
Overall dimensions weightbull Oslash 230times290 mm 40 kg
ALPHA BDZA-96MDetector bull ZnS(Ag) 10 сm2
Measurement range (for Pu-239)bull 01 divide 105 min-1cm-2
Overall dimensions weightbull Oslash 65times240 mm 09 kg
ALPHA BDZA-96SDetector bull ZnS(Ag) 30 сm2
Measurement range (for Pu-239)bull 01 divide 5104 min-1cm-2
Overall dimensions weightbull Oslash 90times240 mm 10 kg
ALPHA BDZA-96TDetector bull Silicon 5 сm2
Measurement range (for Pu-239)bull 01 divide 106 min-1cm-2
Overall dimensions weightbull Oslash 50times60 mm 015 kg
SPC ldquoDozardquoRadiation monitoring equipment
56 57
BETA BDZB-96Detector Scintillator 28 сm2
Measurement range (for Sr-90+Y-90)bull 10 divide 105 min-1cm-2
Energy rangebull 03 divide 30 MeV
Overall dimensions weightbull Oslash 90times230 mm 09 kg
BETA BDZB-99Detector bull GM counter 30 сm2
Measurement range (for Sr-90+Y-90)bull 20 divide 104 min-1см-2
Energy rangebull 012 divide 30 MeV
Overall dimensions weightbull Oslash 88times80 mm 04 kgbull Telescopic pole length 07 m
BETA BDZB-96BDetector bull GM counter 80 сm2
Measurement range (for Sr-90+Y-90)bull 3 divide 104 min-1сm-2
Energy rangebull 012 divide 30 MeV
Overall dimensions weightbull 150times200times110 mm 15 kg
BETA BDZB-96Sbull Detector GM counter 15 сm2
Measurement range (for Sr-90+Y-90)bull 10 divide 3104 min-1cm-2
Energy rangebull 012 divide 30 MeV
Overall dimensions weightbull Oslash 65times65 mm 03 kgbull Telescopic pole length 07 m
BDZB-96
BDZB-99
BDZB-96B
BDZB-96S
EXTERNAL PROBES BETA
GAMMA BDKS-96BDetector bull Tissue-equivalent scintillator Oslash 45times20 mm
Measurement rangebull Dose rate H(10) 01 μSvh divide 1 Svhbull Dose H(10) 01 μSv divide 10 Sv
Energy rangebull 0015 divide 10 MeV
Overall dimensions weightbull Oslash 60times250 mm 085 kg
GAMMA AND BETA BDKS-96SDetector bull Double GM counters
Measurement rangebull Gamma dose rate H(10) 01 μSvh divide 1 mSvhbull Gamma dose H(10) 01 μSv divide 10 Svbull Beta 10 divide 3104 min-1cm-2
Energy rangebull Gamma 005 divide 3 MeVbull Beta 012 divide 3 MeV
Overall dimensions weightbull Oslash 80times80 mm 035 kgbull Telescopic pole length 07 m
GAMMA BDMG-96Detector bull GM counters
Measurement rangebull Dose rate H(10) 01 μSvh divide 10 Svhbull Dose H(10) 01 μSv divide 10 Sv
Energy range bull 005 divide 3 MeV
Overall dimensions weightbull 40times250 mm 05 kgbull Telescopic pole length 07 m 4 m (by request)
EXTERNAL PROBES GAMMA
BDKS-96B
BDMG-96
BDKS-96S
SPC ldquoDozardquoRadiation monitoring equipment
58 59
GAMMA-SEARCH BDVG-96Detector bull Scintillator NaI(Tl) Oslash 63times63 mm
Measurement rangebull Flux density measurement range 4 divide 2000 s-1cm-2
bull Dose rate H(10) for Cs-137 01 divide 30 μSvhbull Sensitivity for Cs-137 3000 (pulsess-1)( μSvh-1)
Overall dimensions weightbull Oslash 88times400 mm 20 kgbull Modular pole length 16 m
GAMMA-SEARCH BDPG-96Detector bull Scintillator NaI(Tl) Oslash 25times40 mm
Measurement rangebull Flux density measurement range 10 divide 8000 s-1cm-2
bull Dose rate H(10) for Cs-137 01 divide 100 μSvhbull Sensitivity for Cs-137 500 (pulsess-1)( μSvh-1)
Overall dimensions weightbull 50times190times480 mm 10 kgbull Telescopic pole length 07 m
GAMMA-SEARCH BDPG-96MDetector bull Scintillator NaI(Tl) Oslash 18times30 mm
Measurement rangebull Flux density measurement range 10 divide 24000 s-1cm-2
bull Dose rate H(10) for Cs-137 01 divide 300 μSvhbull Sensitivity for Cs-137 200 (pulsess-1)( μSvh-1)
Overall dimensions weightbull Oslash 35times320 mm 05 kgbull Telescopic pole length 07 or 38 m
EXTERNAL PROBES GAMMA
BDVG-96
BDPG-96M
BDPG-96
EXTERNAL PROBESGAMMA BDKG-96 STAINLESS STEEL CASING FOR GEOLOGIC APPLICATIONS WELL LOGGINGDetector bull Scintillator NaI(Tl) Oslash 18times30 mm
Measurement rangebull Flux density measurement range 10 divide 105 s-1cm-2
bull Dose rate H(10) for Cs-137 5 divide 2104 μRhbull Sensitivity for Cs-137 200 (pulsess-1)( μSvh-1)
Overall dimensions weightbull Oslash 38times535 mm 36 kgbull Cable length 10 divide 1000 m
NEUTRON BDMN-96Detector bull Scintillator with ZnS(Ag)
Measurement rangebull Dose rate H(10) 01 μSvh divide 01 Svhbull Dose H(10) 01 μSv divide 10 Sv
Energy range bull 0025 eV divide 10 MeV
Overall dimensions weightbull Detector Oslash 54times200 mm 08 kgbull Moderator Oslash 245 mm 73 kg
NEUTRON-SEARCH BDKN-96Detector bull He-3 counter in polyethilene moderator
Measurement rangebull Dose rate H(10) for Pu-Be 01 μSvh divide 01 Svhbull Dose H(10) for Pu-Be 01 μSv divide 10 Sv
Energy range bull 0025 eV divide 14 MeV
Overall dimensions weightbull 295times142times100 mm 225 kg
BDKG-96M
BDMN-96
BDKN-96
SPC ldquoDozardquoRadiation monitoring equipment
60 61
bull No gas supply neededbull Clothing control detachable right hand detector bull Alpha detector optional connection bull Numeric and color (red green) indication of
control resultsbull LED sensor of hand-foot positioning for start of
measurementbull Automatic compensation of gamma background
and contamination of detectorbull Audible alarm signals of the excess of preset
thresholdsbull Measurement value indication min-1cm-2 or
Bqсm2
Reference standards Nuclear IEC 61098
RZB-05D HAND-FOOT-CLOTHING MONITOR
Physical characteristicsDetectors bull Gamma beta - GM countersbull Alpha - scintillatior ZnS(Ag)
Detecting nuclidesbull Alpha Pu-239 U-234 U-238bull Beta Sr-90+Y-90 F-18 Cs-137 Co-60 Tс-99 O-15
N-13 Sr-89 C-11 I-131 Na-22 Ru-106+Rh-106 Tl-204
bull Gamma Tc-99m I-123
Efficiencybull Alpha
Pu-239 40 U-234 25U-238 15
bull Beta Sr-90 +Y-90 40
Measurement range bull Alpha 1 divide 103 min-1cm-2 bull Beta 10 divide 103 min-1cm-2
bull Gamma 5103 divide 5106 min-1cm-2
Energy range bull Alpha 30 divide 80 MeV bull Beta 008 divide 35 MeV bull Gamma 005 divide 30 MeV
Operation temperature range bull Minus 10 divide +50 ordmС
Electrical characteristicsbull Power supply 220 V 50 Hz
Mechanical characteristicsOverall dimensions weight bull 740times750times1180 mm 45 kg
Versionsbull Withwithout alpha detectorbull Indication (min-1cm-2 ) or (Bqсm2)bull Detectors overall dimensions smbull Hand 178 х 235bull Foot 185 х 436
Whole body contamination monitor RZBA-04-04Mbull No gas supply neededbull Compensation for background gamma radiation
and contamination of detector unitsbull Individual threshold setting for each measure-
ment channelbull Visible and audible alarms ldquoCONTAMINATIONrdquo and
ldquoCLEANrdquo bull Indication of contaminated body parts on the
panel with image of the bodybull Optional remote alpha-detector
Physical characteristicsDetectors bull Beta - GM counters scintillatorsbull Alpha - scintillatior ZnS(Ag)
Measurement range bull Beta 5 divide 15000 min-1cm-2
bull Alpha 01 divide 10000 min-1cm-2
Energy range bull Beta 015 divide 25 MeV bull Alpha 40 divide 56 MeV
Operation temperature range bull +5 divide +50 ordmС
Electrical characteristicsPower supply bull 220 V 50 Hz
Interfaces bull RS-232bull RS-485
Mechanical characteristicsOverall dimensions weight bull 2650times940times930 mm 310 kg
Versionsbull Withwithout alpha detectorbull Indication (min-1cm-2 ) or (Bqсm2)
Reference standards Nuclear IEC 61098
RZBA-04-04MWHOLE BODY CONTAMINATION MONITOR
SPC ldquoDozardquoRadiation monitoring equipment
62 63
RZA-05DALPHA HAND-MONITOR
bull No gas supply needed bull Numeric and color (red green) indication of
control resultsbull LED sensor of hand- positioning for start of
measurementbull Audible alarm signals of the excess of preset
thresholdsbull Measurement value indication min-1cm-2 or
Bqсm2
Physical characteristicsDetectors alpha - scintillatior ZnS(Ag)
Efficiencybull Pu-239 20 bull U-234 14bull U-238 8
Measurement range bull 05 divide 105 min-1cm-2
Energy range bull 41 divide 90 MeV
Operation temperature range bull minus 10 divide +50 ordmС
Electrical characteristicsPower supply bull 220 V 50 Hz
Mechanical characteristicsOverall dimensions weight no more bull 740times1400times1450 mm 70 kg
Reference standards Nuclear IEC 61098
bull Simultaneous measurement of alphabeta activi-ties in the sample
bull Active shielding anti-coincidence background subtraction using GM counters
bull Lead shielding 30 mm
UMF-2000 LOW LEVEL ALPHA- BETA- COUNTER
Physical characteristicsDetectors bull Silicon specrometric detector 500 or 1000 mm2
Measurement range bull Alpha 001 divide 1000 Bq bull Beta 01 divide 3000 Bq
Energy range bull Alpha 35 divide 80 MeV bull Beta 005 divide 35 MeV
Electrical characteristicsPower supply bull 220 V 50 Hz
Interfaces bull RS-232bull USB
Mechanical characteristicsOverall dimensions weight bull 337times286times190 mm 22 kg
Versionsbull Detector area 500 mm2
bull Detector area 1000 mm2
UMF-2000 Detector area 1000 mm2
UMF-2000 Detector area 500 mm2
SpectraDec software for alpha-spectrometric measurements
SPC ldquoDozardquoRadiation monitoring equipment
64 65
DRK DOSE AREA PRODUCT METER
DRK-1bull Diagnostic reference level (DRL) of patients
determinationbull Suitable for all basic types of x-ray machines
Physical characteristicsDetector bull Plane-parallel ionization chamber
Measurement range bull 1 divide 104 cGycm2
Electrical characteristicsPower supply bull 220 V 50 Hz
DRK-1M-CTbull Measuring of dose length product
Physical characteristicsDetector bull Pencil Ionization Chamber
Measurement rangebull 05 divide 109 microGym
DRK-1Mbull Measuring of air kerma on sectional area of the
X-ray beam productbull Measuring of air kerma rate on area productbull Measuring of air kerma ratebull Measuring of air kerma
Physical characteristicsDetector bull Plane-parallel ionization chamber
Measurement rangebull 01 divide 109 microGym2
bull 06 divide 6104 microGym2cbull 30 divide 9105 microGycbull 30 divide 9991011 microGyReference standard IEC 60580 2003
bull Measurement of strontium-90 in the foodstuffs agricultural products etc
bull Measurement of gross beta activity in samplebull Self tests using built-in LED
ldquoPROGRESS-BETArdquo SCINTILLATION BETA SPECTROMETER
Physical characteristicsDetector bull Plastic scintillator Oslash70x10 mm
Sample bull Plate Oslash70 mmbull Weight up to 15 g
Energy range bull 02 divide 30 MeV
Minimum detectable activity of Sr-90 in a 10 g sample on a standard planchet Bqsamplebull In case of absence of K-40 in the sample 01 Bqbull In case the activity of K-40 till 5 Bqg 05 Bq
Electrical characteristics Interface bull USB
Mechanical characteristicsWeight bull No more 50 kg
Complete setBasic complete setbull Detector unit with plastic scintillator integrated
power supply amplifier ADC bull Lead shielding bull ldquoProgressrdquo software bull Сheck source for energetic calibration (Sr-90-Y-90) bull Planchet Oslash 70 mm (5 items) bull Sample dencification device bull Procedure manual for measurement of radio-
nuclidesrsquo activity using the scintillation beta spec-trometer ldquoProgressrdquo
Optional equipment and servicebull Personal computer and printer bull Calibrations for radionuclides not included in the
main library of radionuclides
Progress-Beta
Reference standards IEC 61562
SPC ldquoDozardquoRadiation monitoring equipment
66 67
bull Measurement of gamma activity in foodstuffs soil samples and others environmental objects
bull Identification of radionuclides in the sample bull Automatic correction for sample density bull Self-tests using built-in LED
ldquoPROGRESS-GAMMArdquoSCINTILLATION GAMMA SPECTROMETER
Physical characteristicsDetector bull NaI (Tl) Oslash63times63 mm
Validated measurement geometries bull Marinelli beakers (1 liter) Petri dishes (Oslash90 mm)
etc
Energy range bull 02 divide 30 MeV
Minimum detectable activity Bqsamplebull Cs-137 3 Bqbull Th-232 7 Bqbull Ra-226 8 Bq bull К-40 40 Bq
Electrical characteristics Interface bull USB
Mechanical characteristicsWeight bull No more 120 kg
Complete setBasic complete setbull Scintillation detector unit with NaI (Tl) detector
with integrated power supply amplifier and ADC bull Lead shielding 50 mm bull ldquoProgressrdquo software bull Сheck source for energy calibration (Cs-137 +
K-40)bull Marinelli beakers - 1 liter (5 items) bull Petri dishes Oslash 90 mm (5 items) bull Procedure manual for measurement of activity
of radionuclides using the scintillation gamma spectrometer ldquoProgressrdquo
Optional equipment and servicebull Kit for radon measurements including calibration
of ldquoIC-63rdquo geometry for counting the charcoal samples
bull Personal computer and printer bull Calibrations for user defined geometries bull Calibrations for radionuclides not included in the
main library of radionuclides
Progress-Gamma
Reference standards IEC 61563
ldquoPROGRESS-G(P)rdquoPORTABLE SCINTILLATION GAMMA SPECTROMETERbull Field measurements of gamma activity in environ-
mental objects without sampling (4π geometry)bull Laboratory measurement of gamma activity in
foodstuffs soil samples and others environmental objects
bull Identification of radionuclides in the sample bull Automatic correction for sample densitybull Tests using built-in LED
Physical charachteristicsDetector bull NaI (Tl) Oslash45times50 mmbull Lead shielding 20 mm
Validated measurement geometries bull Marinelli beakers (05 liter) Petri dishes (Oslash90 mm)
etc
Energy range bull 02 divide 30 MeV
Minimum detectable activity in 05-litre Marinelli beaker bull Cs-13710 Bqkgbull К-40100 Bqkgbull Ra-22618 Bqkg bull Th-23216 Bqkg
Minimum detectable activity in 30 min (4π geometry) bull Cs-137 2 Bqkgbull К-40 30 Bqkgbull Ra-226 4 Bqkg bull Th-232 3 Bqkg
Electrical characteristicsPower supply bull Rechargeable batterybull 220 V 50 Hz
Interface bull USB RS-232
Weight bull No more than 60 kg
Complete setBasic complete setbull Scinttillation detector unit with NaI(Tl) bull ldquoProgressrdquo softwarebull Сontrol unit ldquoSputnikrdquo for aquisition and analisys
of spectra with built-in memory for spectral databull Casebull Lead shielding (2 cm) for laboratory usebull 05-litre Marinelli beakers ndash 5 itemsbull Na-22 check sourcebull Power adapter BPS-01bull Operation manualbull Procedure manual for measurement of activity
of radionuclides using the scintillation gamma spectrometer ldquoProgressrdquo
Optional equipment and servicebull Kit for radon measurements with charcoalbull Built-in dose rate meterbull Additional memory (RAM) for storage of 64
spectrabull Additional power adapterbull Notebook and printer
Progress-Gamma
Reference standards IEC 61563
SPC ldquoDozardquoRadiation monitoring equipment
68 69
Physical characteristicsDetectorbull Scintillation detector ZnS (Oslash 60 mm)
Samplebull Thin sample - diameter up to 70 mm bull Preparation technique - electro-depositionbull Thick sample - diameter 70 mm weight
200300 mg bull Preparation technique - application of powders
(prepared by radiochemical concentration by water evaporation or by pounding of mineral samples) onto a planchet with the help of spirit
Energy rangebull 15 divide 8 MeV
Minimum detectable activitybull Thin samples no more than 910-3 Bqsamplebull Thick samples no more than 180 Bqkg
Mechanical characteristicsOverall dimensions weightbull 195times120times210 mm 34 kg
Complete setBasic complete setbull Alpha radiometer ldquoProgress-ARrdquobull Check source (uranium isotopes)
Set of accessoriesbull Procedure manual for measurements of radi-
oactivity using scintillation alpha radiometer ldquoProgress-ARrdquo
bull ldquoProgressrdquo software
ldquoProgress-ARrdquo
bull Measurement of gross activity of alpha emitting radionuclides in thin samples
bull Measurement of gross activity of alpha emitting radionuclides in thick samples
bull Measurement of activity deposited on aerosol filters
ldquoPROGRESS-ARrdquoALPHA RADIOMETER
Several fixed positions of the detector enable to perform measurements in various geometries and to estimate the content ofbull Cs-137 in the whole bodybull I-131 in thyroidbull Co-60 Cs-137 Mn-54 Cr-51 in lungsbull Database for storage of measurement data and
resultsbull Uncertainty calculations based on measurement
databull Self tests using built-in LED
ldquoPROGRESSrdquo WHOLE BODY COUNTER
Physical characteristicsDetectorbull scintillation detector NaI (Tl) Oslash63times63 mm
Energy rangebull 02 divide 28 MeV
Minimum detectable activitybull By Cs-137 in the whole body - 1200 Bqbull By I-131 in thyroid - 100 Bqbull By Co-60 Cs-137 Mn-54 Cr-51 in lungs - 200 Bq
Mechanical characteristicsWeight bull No more than 120 kg
Complete setBasic complete setbull Collimator with rotator and holderbull Detector with incorporated ADCbull Patient chair and table for collimatorbull Check source Na-22bull Procedure manual for lifetime measurement of
gamma-emitting radionuclidesrsquo activity in human body using the gamma-spectrometer of human radiation ldquoProgressrdquo
bull laquoProgressraquo software
Optional equipment and servicebull Program of internal radiation committed internal
radiation effective dose calculation by the stand-ard model
bull Background phantombull Personal computer and printer
Collimator with rotator and holder
SPC ldquoDozardquoRadiation monitoring equipment
70 71
bull Categorization of wastes for the purpose of fur-ther processing including wastes with unknown radionuclide composition
bull Measurements during the incoming waste inspec-tion (accepting for storage disposal)
bull Certification of unconditioned and conditioned wastes in closed containers without opening them (at nuclear plants or at facilities providing collection storage transportation conditioning processing temporal storage and final disposal of radioactive waste)
bull Activity measurement of extended objects in situ without opening the equipment
bull Activity measurement of extended objects after opening (for example assessment of tubes used for oil transportation)
MKG-01D ldquoSADOVNIKrdquoSPECTROMETRY SYSTEM
Physical charachteristicsDetectorbull Detector unit GEM (GMX) with HPGe detector and
multi-positioning cryostat CFG-PMOD4-7 with 7 litre Dewar
bull Dose rate probe BDMG-200
Energy range bull With GEM detector 004 divide 30 MeVbull With GMX detector 0005 divide 15 MeVbull Dose rate probe BDMG-200 ndash 005 divide 30 MeV
Measurement rangebull 110-7 divide 10 Svhbull Relative efficiency of detection (in photopeak) at
13325 MeV (Co-60) 10 divide 150
Electrical characteristicsPower supplybull 220 V 50 Hz
Interfacebull USB
Complete setBasic complete setbull Spectrometric detector unit GEM (GMX) with
HPGe detector and multi-positioning cryostat with 7 litre Dewar
bull Portable digital multichannel analyzer DigiDARTbull Dose rate probe BDMG-200bull Autonomous power supply unit with built-in
batterybull Industrial computer keyboardbull Laser range-finderbull Thermographic printerbull Web-camerabull Device equipped with stepper motor for position-
ing of the spectrometric detectorbull Calibration device with reference sources
(Am-241 Co-60 Ba-133 Eu-152) for energy calibration
bull Removable collimators with end capbull Measurement proceduresbull ldquoClasterrdquo software
bull Measurement of gross alpha activity of alpha-emitting radionuclides
bull Measurement of alpha-emitting radionuclides activity in thin-layer samples meeting alpha-spectrometry requirements
Physical characteristicsDetectorbull Silicon ion-implanted 450 mm2
bull Easy to decontaminate thin windowbull dead layer less than 015 μmbull Background count rate in the range 3 divide 9 MeVbull No more than 09 h-1cm-2 for 450 mm2 detector
Energy rangebull 2 divide 9 MeVbull Lower limit of measurement range (minimum
detectable activity) 01 Bqbull Background count rate no more than 100 counts
in 24 hours
Electrical characteristics Power supplybull 220 V 50 Hz
Interfacebull USB
Complete setBasic complete setbull Detector unit with vacuum measuring chamber
and vacuum control systembull Low noise vacuum pump (type 2FY-05B or
equivalent)bull Check sourcebull ldquoProgressrdquo softwarebull Vacuum tube
MKS-01A ldquoMULTIRAD-ASrdquoALPHA SPECTROMETER
SPC ldquoDozardquoRadiation monitoring equipment
72 73
UCRV-2AIRFLOW MONITOR
bull Monitor of the air flow through filter of centralized multichannel sampling system
bull Radiation monitoring system (RMS) integration for internal exposures determination
bull Volume and flow rate measurements of the air that have passed through a analytical filter
bull Bar-code for filter identificationbull Operation as either standalone unit or as a part of
the RMS
Physical characteristicsMeasurement range of air volume bull 001 divide 9999 m3
Operation temperature range bull minus 20 divide +50 ordmС
Electrical characteristicsPower supply bull 220 V 50 Hz
Interface bull RS-485
PVP-06PORTABLE AIR SAMPLER
Air Sampler PVP-06 is indispensable for monitoring the radiation situation where the concentration of radioactive aerosols in the air does not require a sta-tionary sampling equipment Sampling head PVP-06 provides easy change of filters and cartridges
Purposebull To monitor the concentration of radioactive aero-
sols in the air sites
Controlled aerosolsbull Alpha- and beta-active aerosolsbull Daughter products of decay of radon and thoronbull Iodine isotopes
Physical characteristicsTypes of filtersbull Aerosol AFA-RSP-20bull Iodine AFA SI-20
Flow rate bull 33∙10-4 ndash 233∙10-4 m3s (20 divide 140 l min)
Electrical characteristicsPower supply bull 220 V50 Hzbull The vehicle power supply 108 divide 145 Vbull Internal battery
Minimal working time on internal battery to recharge bull 8 hours
Power consumption (at a flow rate of 100 lmin) bull 40 VA
Environment characteristicsOperating temperature bull minus 10 divide +40 deg C
Maximum humidity bull 90
Pressure bull 860 to 1060 hPA
Noise generated by the pump bull lt 55 dBA at 1 m
Mechanical characteristicsDimensions weight bull 241 times 108 times 160 mm 28 kg
Case material bull Plastic
Complete setbull Air sampler PVP-06bull AC power adapterbull Filters AFA-RSP-20 - 100 pcsbull Packaging for filters - 40 pcsbull Casebull Operation manualbull Calibration certificate
Optional equimpient bull Kit for sampling sorption columns of activated
carbon Ř head of sorption columns with protective
covers Ř activated charcoal SKT-3 - 1 pkg (02 L) Ř charocoal samples SC-13 - 8 pcs
bull Car charger bull Tipod bull Shoulder strapbull Calibration stand bull Filters AFA SI-20 - 100 pcs
Consumablesbull Aerosol filters AFA RSP-20bull Iodine filters AFA SI-20
SPC ldquoDozardquoRadiation monitoring equipment
74 75
Calibration of gamma dose and dose rate meters
Calibration ofbull Ambient equivalent dose H(10) meters (Sv Svh)bull Personal equivalent dose Hp(10) meters (Sv Svh)bull Exposure dose X meters (R Rh)bull Two sources in irradiator bull Select source and collimator opening using
tumbler
UPG-P DESKTOP GAMMA BEAM IRRADIATOR
Physical characteristicsRange of reproduced dose rate bull 05 μSvh divide 10 mSvh (50 μRh divide 100 mRh)
Sources activities bull 6times106 6times108 Bq (02 20 mCi) Cs-137
Overall dimensions bull 1250times400times300 mm
Irradiator weight bull Not more than 37 kg
Calibration bench weight bull Not more than 15 kg
Reference standards IEC 60846 IEC 61526
Physical characteristicsDetectorbull Silicon
Measurement range EEC measurement bull Measurement range of radon EEC
10 divide 10bull106 Bqbullm-3
bull Measurement range of thoron EEC 05 divide 10bull104 Bqbullm-3
bull Air flow through the filter 100plusmn05 lmin
Concentration measurementbull Measurement range of radon-222 concentration
in air 10 divide 20bull106 cpsbull Measurement range of 216Po(ThA)
1bull10-3 divide 1bull102 cpsbull Air sampler flow rate
10plusmn02 lminbull Measurement range of radon-222 concentration
in water samples 6 divide 800 Bqbullkg-1
bull Measurement range of radon-222 flux from soil surface 20 divide 103 mBqsbullm2
bull Measurement range of radon-222 concentration with preliminary sampling of air using air sam-plers 20 divide 107 Bqbullm-3
bull Measurement range of radon-222 concentration in samples of soil air 103 divide 106 Bqbullm-3
Operation temperature range bull 1 divide 35 ordmC
Electrical characteristicsPower supply bull 80 VA
Mechanical characteristicsOverall dimensions weight bull 220times200times165 mm 36 kg
ldquoALPHARAD PLUSrdquoRADON THORON amp THEIR PROGENY MONITORbull Measurement of radon and thoron concentration
and effective equivalent concentration (EEC)bull In the airbull In the indoor air of residential public and industri-
al buildings and structuresbull Measurement of radon in drinking water sourcesbull Measurements of radon flux from the soil surface
at land plots allocated for construction of houses public buildings and industrial facilities
bull Measurements of radon concentration in soil air
Reference standards IEC 61577
SPC ldquoDozardquoRadiation monitoring equipment
76 77
UKPN-2M-D NEUTRON BEAM IRRADIATOR
Reference standards IEC 61005 61322
Calibration of neutron dose and dose rate meters
Calibration ofbull Ambient equivalent dose H(10) meters (Sv Svh)bull Personal equivalent dose Hp(10) meters (Sv Svh)bull Flux density of neutrons (cm-2∙s-1)bull Transfer container for temporary storage of
sources bull Red light signal of source working position
Physical carachteristicsRange of reproduced dose ratebull 20 divide 800 μSvh
Range of reproduced flux densitiesbull 10 divide 400 cm-2∙s-1
Type of a source in use bull Pu-Be
Activity of a source in usebull 24х1011 Bq (with density of 107 s-1)
Overall dimensions weight no morebull 3000x750x2000 mm 300 kg
Required room dimensionsbull not less than 7x3x3 m
Electrical characteristicsPower supply bull 220 V 50 Hz
Calibration of gamma dose and dose rate meters
Calibration ofbull Ambient equivalent dose H(10) meters (Sv Svh)bull Personal equivalent dose Hp(10) meters (Sv Svh)bull Exposure dose X meters (R Rh)bull Four sources in irradiator bull Select source and move to working position
return to storage position using special rodbull Transfer container for temporary storage of
sources bull Red light signal of source working position
UPGD-2M-DGAMMA BEAM IRRADIATOR
Physical characteristicsRange of reproduced dose rate bull 05 μSvh divide 50 mSvh (50 μRh divide 5 Rh)
Maximum activity of source bull 2times1011 Bq (50 Ci) Cs-137
Overall dimensionsbull Irradiator 800times500times500 mmbull Guide rails length 30 mbull Height 16 mbull Weight not more than 700 kgbull Required room dimensions not less than 7x3x3 m
Electrical characteristicsPower supply bull 220 V 50 Hz
UPGD-2M-D
Reference standards IEC 60846 IEC 61526 IEC 61066
SPC ldquoDozardquo
78 79
Contents
MEASURING UNITS
DBG-S11D wide range gamma area monitor 40
UDKS-100 gamma and X-ray area monitor 41
UDMN-100 neutron area monitor 41
ALARM UNITS
BAS-2 ldquoMICROrdquo external visual alarm 42
BZS-2 ldquoMicrordquo external audible alarm 42
Illuminated warning signs 43
ldquoImpulsrdquo external display unit 43
UIM-3D area monitor count rate meter 44
DKG-05D personal gamma dosimeter 46
DVS-02D gamma-neutron personal electronic dosimeter 47
DVGI-8D new pen-type personal ionization chamber dosimeters 48
DKG-02U ldquoARBITERrdquo wide range gamma-dosimeter 49
DKG-07D ldquoDROZDrdquo gamma-dosimeter 50
MKS-15D ldquoSNEGIRrdquo multi ndash purpose radiation survey meter 51
SRPS-05D gamma monitor 52
DOZA-TLD multipurpose TLD system 53
DKS-96 universal radiation survey meter 54
EXTERNAL PROBES ALPHA
Alpha BDZA-96 55
Alpha BDZA-96B 55
Alpha BDZA-96M 55
Alpha BDZA-96S 55
Alpha BDZA-96T 55
EXTERNAL PROBES BETA
Beta BDZB-96 56
Beta BDZB-99 56
Beta BDZB-96B 56
Beta BDZB-96S 56
EXTERNAL PROBES GAMMA
Gamma BDKS-96B 57
Gamma and beta BDKS-96S 57
Gamma BDMG-96 57
EXTERNAL PROBES GAMMA
Gamma-search BDVG-96 58
Gamma-search BDPG-96 58
ContentsRadiation monitoring systemldquoPELIKANrdquo Radiation monitoring system (RMS) 6
BDMG-101 high range gamma area monitor 10
DBG-S11D wide range gamma area monitor 11
BDRG-52 high range gamma area monitor for accident and post-accident conditions 12
UDGP-01 Liquid technological environments monitor 13
UDMN-100 neutron area monitor 14
UDKG-100 Wel Liquid gamma monitor 14
BOP-1M data processing and transmission unit 15
UDA-1AB particulate monitor 16
UDG-1B noble gas monitor 17
UDG-03D noble gas monitor 18
UDI-1B iodine monitor 19
UDGB-01 noble gasesH-3C-14 monitor 20
UDGP-01 steam generator leakage monitor 21
UPPVM air flow parameters monitor 22
ldquoIMPULSrdquo external display unit 23
BI-2 remote display amp alarm unit 24
BASBAS-1s external alarm 25
SKGAV stack monitor 26
RMS software 28
RMS workstation ndash operator console 29
Configurator software 29
RM RACK radiation monitoring rack 30
SRKS-01D criticality accident alarm system 32
ldquoATLANT-Mrdquo environmental radiation monitoring system 34
ldquoBREEZErdquo high-volume air sampler 35
ldquoGAMMA-SENSORrdquo gamma-survey system 36
Radiation monitoring equipmentAREA MONITOR ldquoFREGATrdquo 38
BPI-1D local display unit 39
80
Gamma-search BDPG-96M 58
Gamma BDKG-96 stainless steel casing for geologic applications well logging 59
EXTERNAL PROBES NEUTRON
Neutron BDMN-96 59
Neutron-search BDKN-96 59
RZB-05D Hand-foot-clothing monitor 60
RZBA-04-04M whole body contamination monitor 61
RZA-05D alpha hand-monitor 62
UMF-2000 low level alpha- beta- counter 63
DRK dose area product meter 64
ldquoPROGRESS-BETArdquo scintillation beta spectrometer 65
ldquoPROGRESS-GAMMArdquo scintillation gamma spectrometer 66
ldquoPROGRESS-G(P)rdquo portable scintillation gamma spectrometer 67
ldquoPROGRESS-ARrdquo alpha radiometer 68
ldquoPROGRESSrdquo whole body counter 69
MKG-01D ldquoSADOVNIKrdquo spectrometry system 70
MKS-01A ldquoMULTIRAD-ASrdquo alpha spectrometer 71
UCRV-2 airflow monitor 72
PVP-06 portable air sampler 73
ldquoALPHARAD PLUSrdquo radon thoron amp their progeny monitor 74
UPG-P desktop gamma beam irradiator 75
UPGD-2M-D gamma beam irradiator 76
UKPN-2M-D neutron beam irradiator 77
SPC ldquoDozardquoRadiation monitoring equipment
52 53
Physical characteristicsDetectorbull GM counter
Measurement range bull 01 μSvh divide 20 mSvh
Energy range bull 005 divide 30 MeV
Threshold setting range bull 03 μSvh divide 20 mSvh
Step change of the thresholdbull In the range 03 divide 10 μSvh with the step
001 μSvhbull In the range 10 divide 100 μSvh with the step
01 μSvhbull In the range 100 divide 2000 μSvh with the step
10 μSvh
Electrical characteristicsPower supply bull 220 V 50 Hz bull Relay output
Mechanical characteristicsProtection index bull IP 40
Overall dimensions weight bull 226times120times75 mm 07 kg
Alarmbull Sound alarm 80 divide 100 dBA at distance 1 mbull Visual alarm redbull Connection of the external alarm signaling unit
Reference standards Nuclear IEC 60846 IEC 60532
Continuous automatic monitoring of the ambient dose equivalent rate bull Measurement of gamma dose rate H(10)bull Audible and visual alarm signals for preset
thresholdsbull Switching on the external signaling or executive
devices
SRPS-05D GAMMA MONITOR
Measurement ofbull Gamma and X-ray personal dose equivalent
Hp(10)bull Neutron personal dose equivalent Hp(10)bull Lens dose equivalent Hp(3)bull Skin dose equivalent Hp(007)bull TLD reader day-to-day tests using built-in LEDbull No needs nitrogen for heating
Physical charachteristicsDetectors bull 7LiF Mg Ti (gamma beta)bull 6LiF Mg Ti (neutron)
Gamma and X-ray Hp(10) Measurement range bull 500 μSv divide 10 Sv
Energy range bull 0015 divide 30 MeV
Neutron Hp(10)Measurement range bull 01 mSv divide 100 mSv
Energy range bull 0025 eV divide 10 MeV
Beta and photons Hp(007) Hp(3) Measurement range bull 2 mSv divide 100 Sv
Energy range bull Beta 025 divide 35 MeVbull Photons lt15 keV
Mechanical characteristicsDosimeters overall dimensions weight bull Gamma Hp(10) DTL-2 holder - 62times26times16 mm
16 gbull DTU holder - 42times28times18 mm 8 gbull Lens Hp(3) face skin Hp(007) Oslash 32times16 mm 9 gbull Finger skin Hp(007) 90times20times2 mm 1 gbull Neutron gamma Hp(10) 48times40times20 mm 30 g
Reference standards Nuclear IEC 61066
DTL-2 DTU-2
MKD (A-type) DVNG-M
DOZA-TLD MULTIPURPOSE TLD SYSTEM
SPC ldquoDozardquoRadiation monitoring equipment
54 55
Continuous and pulsed gamma and X-ray dose H(10) and dose-rate measurementbull Alpha beta and gamma contamination surveybull Neutron dose H(10) and dose-rate measurementbull Gamma radiation flux density in boreholes and
liquid media measurement
Electrical characteristicsPower supply bull UIK-05 four C-size batteriesbull UIK-05-01 rechargeable batterybull UIK-06 rechargeable battery
Interfaces bull RS-232bull USB (via adapter)
bull Detector type automatic determination and corre-sponding measurement modes selection
bull Alarm threshold settings ndash for dose dose-rate alpha and beta contaminations
bull ldquoDetectrdquo and ldquoLocaterdquo modes for survey probes
Reference standards Nuclear IEC 60846 IEC 60325 IEC 61005 IEC 62363
Case
UIK-06 control unit165times78times48 mm 03 kg
DKS-96UNIVERSAL RADIATION SURVEY METER
UIK-05 control unit202times86times90 mm 10 kg
BDZA-96
BDZA-96B
BDZA-96M
BDZA-96S
BDZA-96T
EXTERNAL PROBES ALPHAALPHA BDZA-96Detector bull ZnS(Ag) 70 cm2
Measurement range (for Pu-239)bull 01 divide 104 min-1cm-2
Overall dimensions weightbull Oslash 130times240 mm 11 kg
ALPHA BDZA-96BDetector bull ZnS(Ag) 300 сm2
Measurement range (for Pu-239)bull 01 divide 2103 min-1cm-2
Overall dimensions weightbull Oslash 230times290 mm 40 kg
ALPHA BDZA-96MDetector bull ZnS(Ag) 10 сm2
Measurement range (for Pu-239)bull 01 divide 105 min-1cm-2
Overall dimensions weightbull Oslash 65times240 mm 09 kg
ALPHA BDZA-96SDetector bull ZnS(Ag) 30 сm2
Measurement range (for Pu-239)bull 01 divide 5104 min-1cm-2
Overall dimensions weightbull Oslash 90times240 mm 10 kg
ALPHA BDZA-96TDetector bull Silicon 5 сm2
Measurement range (for Pu-239)bull 01 divide 106 min-1cm-2
Overall dimensions weightbull Oslash 50times60 mm 015 kg
SPC ldquoDozardquoRadiation monitoring equipment
56 57
BETA BDZB-96Detector Scintillator 28 сm2
Measurement range (for Sr-90+Y-90)bull 10 divide 105 min-1cm-2
Energy rangebull 03 divide 30 MeV
Overall dimensions weightbull Oslash 90times230 mm 09 kg
BETA BDZB-99Detector bull GM counter 30 сm2
Measurement range (for Sr-90+Y-90)bull 20 divide 104 min-1см-2
Energy rangebull 012 divide 30 MeV
Overall dimensions weightbull Oslash 88times80 mm 04 kgbull Telescopic pole length 07 m
BETA BDZB-96BDetector bull GM counter 80 сm2
Measurement range (for Sr-90+Y-90)bull 3 divide 104 min-1сm-2
Energy rangebull 012 divide 30 MeV
Overall dimensions weightbull 150times200times110 mm 15 kg
BETA BDZB-96Sbull Detector GM counter 15 сm2
Measurement range (for Sr-90+Y-90)bull 10 divide 3104 min-1cm-2
Energy rangebull 012 divide 30 MeV
Overall dimensions weightbull Oslash 65times65 mm 03 kgbull Telescopic pole length 07 m
BDZB-96
BDZB-99
BDZB-96B
BDZB-96S
EXTERNAL PROBES BETA
GAMMA BDKS-96BDetector bull Tissue-equivalent scintillator Oslash 45times20 mm
Measurement rangebull Dose rate H(10) 01 μSvh divide 1 Svhbull Dose H(10) 01 μSv divide 10 Sv
Energy rangebull 0015 divide 10 MeV
Overall dimensions weightbull Oslash 60times250 mm 085 kg
GAMMA AND BETA BDKS-96SDetector bull Double GM counters
Measurement rangebull Gamma dose rate H(10) 01 μSvh divide 1 mSvhbull Gamma dose H(10) 01 μSv divide 10 Svbull Beta 10 divide 3104 min-1cm-2
Energy rangebull Gamma 005 divide 3 MeVbull Beta 012 divide 3 MeV
Overall dimensions weightbull Oslash 80times80 mm 035 kgbull Telescopic pole length 07 m
GAMMA BDMG-96Detector bull GM counters
Measurement rangebull Dose rate H(10) 01 μSvh divide 10 Svhbull Dose H(10) 01 μSv divide 10 Sv
Energy range bull 005 divide 3 MeV
Overall dimensions weightbull 40times250 mm 05 kgbull Telescopic pole length 07 m 4 m (by request)
EXTERNAL PROBES GAMMA
BDKS-96B
BDMG-96
BDKS-96S
SPC ldquoDozardquoRadiation monitoring equipment
58 59
GAMMA-SEARCH BDVG-96Detector bull Scintillator NaI(Tl) Oslash 63times63 mm
Measurement rangebull Flux density measurement range 4 divide 2000 s-1cm-2
bull Dose rate H(10) for Cs-137 01 divide 30 μSvhbull Sensitivity for Cs-137 3000 (pulsess-1)( μSvh-1)
Overall dimensions weightbull Oslash 88times400 mm 20 kgbull Modular pole length 16 m
GAMMA-SEARCH BDPG-96Detector bull Scintillator NaI(Tl) Oslash 25times40 mm
Measurement rangebull Flux density measurement range 10 divide 8000 s-1cm-2
bull Dose rate H(10) for Cs-137 01 divide 100 μSvhbull Sensitivity for Cs-137 500 (pulsess-1)( μSvh-1)
Overall dimensions weightbull 50times190times480 mm 10 kgbull Telescopic pole length 07 m
GAMMA-SEARCH BDPG-96MDetector bull Scintillator NaI(Tl) Oslash 18times30 mm
Measurement rangebull Flux density measurement range 10 divide 24000 s-1cm-2
bull Dose rate H(10) for Cs-137 01 divide 300 μSvhbull Sensitivity for Cs-137 200 (pulsess-1)( μSvh-1)
Overall dimensions weightbull Oslash 35times320 mm 05 kgbull Telescopic pole length 07 or 38 m
EXTERNAL PROBES GAMMA
BDVG-96
BDPG-96M
BDPG-96
EXTERNAL PROBESGAMMA BDKG-96 STAINLESS STEEL CASING FOR GEOLOGIC APPLICATIONS WELL LOGGINGDetector bull Scintillator NaI(Tl) Oslash 18times30 mm
Measurement rangebull Flux density measurement range 10 divide 105 s-1cm-2
bull Dose rate H(10) for Cs-137 5 divide 2104 μRhbull Sensitivity for Cs-137 200 (pulsess-1)( μSvh-1)
Overall dimensions weightbull Oslash 38times535 mm 36 kgbull Cable length 10 divide 1000 m
NEUTRON BDMN-96Detector bull Scintillator with ZnS(Ag)
Measurement rangebull Dose rate H(10) 01 μSvh divide 01 Svhbull Dose H(10) 01 μSv divide 10 Sv
Energy range bull 0025 eV divide 10 MeV
Overall dimensions weightbull Detector Oslash 54times200 mm 08 kgbull Moderator Oslash 245 mm 73 kg
NEUTRON-SEARCH BDKN-96Detector bull He-3 counter in polyethilene moderator
Measurement rangebull Dose rate H(10) for Pu-Be 01 μSvh divide 01 Svhbull Dose H(10) for Pu-Be 01 μSv divide 10 Sv
Energy range bull 0025 eV divide 14 MeV
Overall dimensions weightbull 295times142times100 mm 225 kg
BDKG-96M
BDMN-96
BDKN-96
SPC ldquoDozardquoRadiation monitoring equipment
60 61
bull No gas supply neededbull Clothing control detachable right hand detector bull Alpha detector optional connection bull Numeric and color (red green) indication of
control resultsbull LED sensor of hand-foot positioning for start of
measurementbull Automatic compensation of gamma background
and contamination of detectorbull Audible alarm signals of the excess of preset
thresholdsbull Measurement value indication min-1cm-2 or
Bqсm2
Reference standards Nuclear IEC 61098
RZB-05D HAND-FOOT-CLOTHING MONITOR
Physical characteristicsDetectors bull Gamma beta - GM countersbull Alpha - scintillatior ZnS(Ag)
Detecting nuclidesbull Alpha Pu-239 U-234 U-238bull Beta Sr-90+Y-90 F-18 Cs-137 Co-60 Tс-99 O-15
N-13 Sr-89 C-11 I-131 Na-22 Ru-106+Rh-106 Tl-204
bull Gamma Tc-99m I-123
Efficiencybull Alpha
Pu-239 40 U-234 25U-238 15
bull Beta Sr-90 +Y-90 40
Measurement range bull Alpha 1 divide 103 min-1cm-2 bull Beta 10 divide 103 min-1cm-2
bull Gamma 5103 divide 5106 min-1cm-2
Energy range bull Alpha 30 divide 80 MeV bull Beta 008 divide 35 MeV bull Gamma 005 divide 30 MeV
Operation temperature range bull Minus 10 divide +50 ordmС
Electrical characteristicsbull Power supply 220 V 50 Hz
Mechanical characteristicsOverall dimensions weight bull 740times750times1180 mm 45 kg
Versionsbull Withwithout alpha detectorbull Indication (min-1cm-2 ) or (Bqсm2)bull Detectors overall dimensions smbull Hand 178 х 235bull Foot 185 х 436
Whole body contamination monitor RZBA-04-04Mbull No gas supply neededbull Compensation for background gamma radiation
and contamination of detector unitsbull Individual threshold setting for each measure-
ment channelbull Visible and audible alarms ldquoCONTAMINATIONrdquo and
ldquoCLEANrdquo bull Indication of contaminated body parts on the
panel with image of the bodybull Optional remote alpha-detector
Physical characteristicsDetectors bull Beta - GM counters scintillatorsbull Alpha - scintillatior ZnS(Ag)
Measurement range bull Beta 5 divide 15000 min-1cm-2
bull Alpha 01 divide 10000 min-1cm-2
Energy range bull Beta 015 divide 25 MeV bull Alpha 40 divide 56 MeV
Operation temperature range bull +5 divide +50 ordmС
Electrical characteristicsPower supply bull 220 V 50 Hz
Interfaces bull RS-232bull RS-485
Mechanical characteristicsOverall dimensions weight bull 2650times940times930 mm 310 kg
Versionsbull Withwithout alpha detectorbull Indication (min-1cm-2 ) or (Bqсm2)
Reference standards Nuclear IEC 61098
RZBA-04-04MWHOLE BODY CONTAMINATION MONITOR
SPC ldquoDozardquoRadiation monitoring equipment
62 63
RZA-05DALPHA HAND-MONITOR
bull No gas supply needed bull Numeric and color (red green) indication of
control resultsbull LED sensor of hand- positioning for start of
measurementbull Audible alarm signals of the excess of preset
thresholdsbull Measurement value indication min-1cm-2 or
Bqсm2
Physical characteristicsDetectors alpha - scintillatior ZnS(Ag)
Efficiencybull Pu-239 20 bull U-234 14bull U-238 8
Measurement range bull 05 divide 105 min-1cm-2
Energy range bull 41 divide 90 MeV
Operation temperature range bull minus 10 divide +50 ordmС
Electrical characteristicsPower supply bull 220 V 50 Hz
Mechanical characteristicsOverall dimensions weight no more bull 740times1400times1450 mm 70 kg
Reference standards Nuclear IEC 61098
bull Simultaneous measurement of alphabeta activi-ties in the sample
bull Active shielding anti-coincidence background subtraction using GM counters
bull Lead shielding 30 mm
UMF-2000 LOW LEVEL ALPHA- BETA- COUNTER
Physical characteristicsDetectors bull Silicon specrometric detector 500 or 1000 mm2
Measurement range bull Alpha 001 divide 1000 Bq bull Beta 01 divide 3000 Bq
Energy range bull Alpha 35 divide 80 MeV bull Beta 005 divide 35 MeV
Electrical characteristicsPower supply bull 220 V 50 Hz
Interfaces bull RS-232bull USB
Mechanical characteristicsOverall dimensions weight bull 337times286times190 mm 22 kg
Versionsbull Detector area 500 mm2
bull Detector area 1000 mm2
UMF-2000 Detector area 1000 mm2
UMF-2000 Detector area 500 mm2
SpectraDec software for alpha-spectrometric measurements
SPC ldquoDozardquoRadiation monitoring equipment
64 65
DRK DOSE AREA PRODUCT METER
DRK-1bull Diagnostic reference level (DRL) of patients
determinationbull Suitable for all basic types of x-ray machines
Physical characteristicsDetector bull Plane-parallel ionization chamber
Measurement range bull 1 divide 104 cGycm2
Electrical characteristicsPower supply bull 220 V 50 Hz
DRK-1M-CTbull Measuring of dose length product
Physical characteristicsDetector bull Pencil Ionization Chamber
Measurement rangebull 05 divide 109 microGym
DRK-1Mbull Measuring of air kerma on sectional area of the
X-ray beam productbull Measuring of air kerma rate on area productbull Measuring of air kerma ratebull Measuring of air kerma
Physical characteristicsDetector bull Plane-parallel ionization chamber
Measurement rangebull 01 divide 109 microGym2
bull 06 divide 6104 microGym2cbull 30 divide 9105 microGycbull 30 divide 9991011 microGyReference standard IEC 60580 2003
bull Measurement of strontium-90 in the foodstuffs agricultural products etc
bull Measurement of gross beta activity in samplebull Self tests using built-in LED
ldquoPROGRESS-BETArdquo SCINTILLATION BETA SPECTROMETER
Physical characteristicsDetector bull Plastic scintillator Oslash70x10 mm
Sample bull Plate Oslash70 mmbull Weight up to 15 g
Energy range bull 02 divide 30 MeV
Minimum detectable activity of Sr-90 in a 10 g sample on a standard planchet Bqsamplebull In case of absence of K-40 in the sample 01 Bqbull In case the activity of K-40 till 5 Bqg 05 Bq
Electrical characteristics Interface bull USB
Mechanical characteristicsWeight bull No more 50 kg
Complete setBasic complete setbull Detector unit with plastic scintillator integrated
power supply amplifier ADC bull Lead shielding bull ldquoProgressrdquo software bull Сheck source for energetic calibration (Sr-90-Y-90) bull Planchet Oslash 70 mm (5 items) bull Sample dencification device bull Procedure manual for measurement of radio-
nuclidesrsquo activity using the scintillation beta spec-trometer ldquoProgressrdquo
Optional equipment and servicebull Personal computer and printer bull Calibrations for radionuclides not included in the
main library of radionuclides
Progress-Beta
Reference standards IEC 61562
SPC ldquoDozardquoRadiation monitoring equipment
66 67
bull Measurement of gamma activity in foodstuffs soil samples and others environmental objects
bull Identification of radionuclides in the sample bull Automatic correction for sample density bull Self-tests using built-in LED
ldquoPROGRESS-GAMMArdquoSCINTILLATION GAMMA SPECTROMETER
Physical characteristicsDetector bull NaI (Tl) Oslash63times63 mm
Validated measurement geometries bull Marinelli beakers (1 liter) Petri dishes (Oslash90 mm)
etc
Energy range bull 02 divide 30 MeV
Minimum detectable activity Bqsamplebull Cs-137 3 Bqbull Th-232 7 Bqbull Ra-226 8 Bq bull К-40 40 Bq
Electrical characteristics Interface bull USB
Mechanical characteristicsWeight bull No more 120 kg
Complete setBasic complete setbull Scintillation detector unit with NaI (Tl) detector
with integrated power supply amplifier and ADC bull Lead shielding 50 mm bull ldquoProgressrdquo software bull Сheck source for energy calibration (Cs-137 +
K-40)bull Marinelli beakers - 1 liter (5 items) bull Petri dishes Oslash 90 mm (5 items) bull Procedure manual for measurement of activity
of radionuclides using the scintillation gamma spectrometer ldquoProgressrdquo
Optional equipment and servicebull Kit for radon measurements including calibration
of ldquoIC-63rdquo geometry for counting the charcoal samples
bull Personal computer and printer bull Calibrations for user defined geometries bull Calibrations for radionuclides not included in the
main library of radionuclides
Progress-Gamma
Reference standards IEC 61563
ldquoPROGRESS-G(P)rdquoPORTABLE SCINTILLATION GAMMA SPECTROMETERbull Field measurements of gamma activity in environ-
mental objects without sampling (4π geometry)bull Laboratory measurement of gamma activity in
foodstuffs soil samples and others environmental objects
bull Identification of radionuclides in the sample bull Automatic correction for sample densitybull Tests using built-in LED
Physical charachteristicsDetector bull NaI (Tl) Oslash45times50 mmbull Lead shielding 20 mm
Validated measurement geometries bull Marinelli beakers (05 liter) Petri dishes (Oslash90 mm)
etc
Energy range bull 02 divide 30 MeV
Minimum detectable activity in 05-litre Marinelli beaker bull Cs-13710 Bqkgbull К-40100 Bqkgbull Ra-22618 Bqkg bull Th-23216 Bqkg
Minimum detectable activity in 30 min (4π geometry) bull Cs-137 2 Bqkgbull К-40 30 Bqkgbull Ra-226 4 Bqkg bull Th-232 3 Bqkg
Electrical characteristicsPower supply bull Rechargeable batterybull 220 V 50 Hz
Interface bull USB RS-232
Weight bull No more than 60 kg
Complete setBasic complete setbull Scinttillation detector unit with NaI(Tl) bull ldquoProgressrdquo softwarebull Сontrol unit ldquoSputnikrdquo for aquisition and analisys
of spectra with built-in memory for spectral databull Casebull Lead shielding (2 cm) for laboratory usebull 05-litre Marinelli beakers ndash 5 itemsbull Na-22 check sourcebull Power adapter BPS-01bull Operation manualbull Procedure manual for measurement of activity
of radionuclides using the scintillation gamma spectrometer ldquoProgressrdquo
Optional equipment and servicebull Kit for radon measurements with charcoalbull Built-in dose rate meterbull Additional memory (RAM) for storage of 64
spectrabull Additional power adapterbull Notebook and printer
Progress-Gamma
Reference standards IEC 61563
SPC ldquoDozardquoRadiation monitoring equipment
68 69
Physical characteristicsDetectorbull Scintillation detector ZnS (Oslash 60 mm)
Samplebull Thin sample - diameter up to 70 mm bull Preparation technique - electro-depositionbull Thick sample - diameter 70 mm weight
200300 mg bull Preparation technique - application of powders
(prepared by radiochemical concentration by water evaporation or by pounding of mineral samples) onto a planchet with the help of spirit
Energy rangebull 15 divide 8 MeV
Minimum detectable activitybull Thin samples no more than 910-3 Bqsamplebull Thick samples no more than 180 Bqkg
Mechanical characteristicsOverall dimensions weightbull 195times120times210 mm 34 kg
Complete setBasic complete setbull Alpha radiometer ldquoProgress-ARrdquobull Check source (uranium isotopes)
Set of accessoriesbull Procedure manual for measurements of radi-
oactivity using scintillation alpha radiometer ldquoProgress-ARrdquo
bull ldquoProgressrdquo software
ldquoProgress-ARrdquo
bull Measurement of gross activity of alpha emitting radionuclides in thin samples
bull Measurement of gross activity of alpha emitting radionuclides in thick samples
bull Measurement of activity deposited on aerosol filters
ldquoPROGRESS-ARrdquoALPHA RADIOMETER
Several fixed positions of the detector enable to perform measurements in various geometries and to estimate the content ofbull Cs-137 in the whole bodybull I-131 in thyroidbull Co-60 Cs-137 Mn-54 Cr-51 in lungsbull Database for storage of measurement data and
resultsbull Uncertainty calculations based on measurement
databull Self tests using built-in LED
ldquoPROGRESSrdquo WHOLE BODY COUNTER
Physical characteristicsDetectorbull scintillation detector NaI (Tl) Oslash63times63 mm
Energy rangebull 02 divide 28 MeV
Minimum detectable activitybull By Cs-137 in the whole body - 1200 Bqbull By I-131 in thyroid - 100 Bqbull By Co-60 Cs-137 Mn-54 Cr-51 in lungs - 200 Bq
Mechanical characteristicsWeight bull No more than 120 kg
Complete setBasic complete setbull Collimator with rotator and holderbull Detector with incorporated ADCbull Patient chair and table for collimatorbull Check source Na-22bull Procedure manual for lifetime measurement of
gamma-emitting radionuclidesrsquo activity in human body using the gamma-spectrometer of human radiation ldquoProgressrdquo
bull laquoProgressraquo software
Optional equipment and servicebull Program of internal radiation committed internal
radiation effective dose calculation by the stand-ard model
bull Background phantombull Personal computer and printer
Collimator with rotator and holder
SPC ldquoDozardquoRadiation monitoring equipment
70 71
bull Categorization of wastes for the purpose of fur-ther processing including wastes with unknown radionuclide composition
bull Measurements during the incoming waste inspec-tion (accepting for storage disposal)
bull Certification of unconditioned and conditioned wastes in closed containers without opening them (at nuclear plants or at facilities providing collection storage transportation conditioning processing temporal storage and final disposal of radioactive waste)
bull Activity measurement of extended objects in situ without opening the equipment
bull Activity measurement of extended objects after opening (for example assessment of tubes used for oil transportation)
MKG-01D ldquoSADOVNIKrdquoSPECTROMETRY SYSTEM
Physical charachteristicsDetectorbull Detector unit GEM (GMX) with HPGe detector and
multi-positioning cryostat CFG-PMOD4-7 with 7 litre Dewar
bull Dose rate probe BDMG-200
Energy range bull With GEM detector 004 divide 30 MeVbull With GMX detector 0005 divide 15 MeVbull Dose rate probe BDMG-200 ndash 005 divide 30 MeV
Measurement rangebull 110-7 divide 10 Svhbull Relative efficiency of detection (in photopeak) at
13325 MeV (Co-60) 10 divide 150
Electrical characteristicsPower supplybull 220 V 50 Hz
Interfacebull USB
Complete setBasic complete setbull Spectrometric detector unit GEM (GMX) with
HPGe detector and multi-positioning cryostat with 7 litre Dewar
bull Portable digital multichannel analyzer DigiDARTbull Dose rate probe BDMG-200bull Autonomous power supply unit with built-in
batterybull Industrial computer keyboardbull Laser range-finderbull Thermographic printerbull Web-camerabull Device equipped with stepper motor for position-
ing of the spectrometric detectorbull Calibration device with reference sources
(Am-241 Co-60 Ba-133 Eu-152) for energy calibration
bull Removable collimators with end capbull Measurement proceduresbull ldquoClasterrdquo software
bull Measurement of gross alpha activity of alpha-emitting radionuclides
bull Measurement of alpha-emitting radionuclides activity in thin-layer samples meeting alpha-spectrometry requirements
Physical characteristicsDetectorbull Silicon ion-implanted 450 mm2
bull Easy to decontaminate thin windowbull dead layer less than 015 μmbull Background count rate in the range 3 divide 9 MeVbull No more than 09 h-1cm-2 for 450 mm2 detector
Energy rangebull 2 divide 9 MeVbull Lower limit of measurement range (minimum
detectable activity) 01 Bqbull Background count rate no more than 100 counts
in 24 hours
Electrical characteristics Power supplybull 220 V 50 Hz
Interfacebull USB
Complete setBasic complete setbull Detector unit with vacuum measuring chamber
and vacuum control systembull Low noise vacuum pump (type 2FY-05B or
equivalent)bull Check sourcebull ldquoProgressrdquo softwarebull Vacuum tube
MKS-01A ldquoMULTIRAD-ASrdquoALPHA SPECTROMETER
SPC ldquoDozardquoRadiation monitoring equipment
72 73
UCRV-2AIRFLOW MONITOR
bull Monitor of the air flow through filter of centralized multichannel sampling system
bull Radiation monitoring system (RMS) integration for internal exposures determination
bull Volume and flow rate measurements of the air that have passed through a analytical filter
bull Bar-code for filter identificationbull Operation as either standalone unit or as a part of
the RMS
Physical characteristicsMeasurement range of air volume bull 001 divide 9999 m3
Operation temperature range bull minus 20 divide +50 ordmС
Electrical characteristicsPower supply bull 220 V 50 Hz
Interface bull RS-485
PVP-06PORTABLE AIR SAMPLER
Air Sampler PVP-06 is indispensable for monitoring the radiation situation where the concentration of radioactive aerosols in the air does not require a sta-tionary sampling equipment Sampling head PVP-06 provides easy change of filters and cartridges
Purposebull To monitor the concentration of radioactive aero-
sols in the air sites
Controlled aerosolsbull Alpha- and beta-active aerosolsbull Daughter products of decay of radon and thoronbull Iodine isotopes
Physical characteristicsTypes of filtersbull Aerosol AFA-RSP-20bull Iodine AFA SI-20
Flow rate bull 33∙10-4 ndash 233∙10-4 m3s (20 divide 140 l min)
Electrical characteristicsPower supply bull 220 V50 Hzbull The vehicle power supply 108 divide 145 Vbull Internal battery
Minimal working time on internal battery to recharge bull 8 hours
Power consumption (at a flow rate of 100 lmin) bull 40 VA
Environment characteristicsOperating temperature bull minus 10 divide +40 deg C
Maximum humidity bull 90
Pressure bull 860 to 1060 hPA
Noise generated by the pump bull lt 55 dBA at 1 m
Mechanical characteristicsDimensions weight bull 241 times 108 times 160 mm 28 kg
Case material bull Plastic
Complete setbull Air sampler PVP-06bull AC power adapterbull Filters AFA-RSP-20 - 100 pcsbull Packaging for filters - 40 pcsbull Casebull Operation manualbull Calibration certificate
Optional equimpient bull Kit for sampling sorption columns of activated
carbon Ř head of sorption columns with protective
covers Ř activated charcoal SKT-3 - 1 pkg (02 L) Ř charocoal samples SC-13 - 8 pcs
bull Car charger bull Tipod bull Shoulder strapbull Calibration stand bull Filters AFA SI-20 - 100 pcs
Consumablesbull Aerosol filters AFA RSP-20bull Iodine filters AFA SI-20
SPC ldquoDozardquoRadiation monitoring equipment
74 75
Calibration of gamma dose and dose rate meters
Calibration ofbull Ambient equivalent dose H(10) meters (Sv Svh)bull Personal equivalent dose Hp(10) meters (Sv Svh)bull Exposure dose X meters (R Rh)bull Two sources in irradiator bull Select source and collimator opening using
tumbler
UPG-P DESKTOP GAMMA BEAM IRRADIATOR
Physical characteristicsRange of reproduced dose rate bull 05 μSvh divide 10 mSvh (50 μRh divide 100 mRh)
Sources activities bull 6times106 6times108 Bq (02 20 mCi) Cs-137
Overall dimensions bull 1250times400times300 mm
Irradiator weight bull Not more than 37 kg
Calibration bench weight bull Not more than 15 kg
Reference standards IEC 60846 IEC 61526
Physical characteristicsDetectorbull Silicon
Measurement range EEC measurement bull Measurement range of radon EEC
10 divide 10bull106 Bqbullm-3
bull Measurement range of thoron EEC 05 divide 10bull104 Bqbullm-3
bull Air flow through the filter 100plusmn05 lmin
Concentration measurementbull Measurement range of radon-222 concentration
in air 10 divide 20bull106 cpsbull Measurement range of 216Po(ThA)
1bull10-3 divide 1bull102 cpsbull Air sampler flow rate
10plusmn02 lminbull Measurement range of radon-222 concentration
in water samples 6 divide 800 Bqbullkg-1
bull Measurement range of radon-222 flux from soil surface 20 divide 103 mBqsbullm2
bull Measurement range of radon-222 concentration with preliminary sampling of air using air sam-plers 20 divide 107 Bqbullm-3
bull Measurement range of radon-222 concentration in samples of soil air 103 divide 106 Bqbullm-3
Operation temperature range bull 1 divide 35 ordmC
Electrical characteristicsPower supply bull 80 VA
Mechanical characteristicsOverall dimensions weight bull 220times200times165 mm 36 kg
ldquoALPHARAD PLUSrdquoRADON THORON amp THEIR PROGENY MONITORbull Measurement of radon and thoron concentration
and effective equivalent concentration (EEC)bull In the airbull In the indoor air of residential public and industri-
al buildings and structuresbull Measurement of radon in drinking water sourcesbull Measurements of radon flux from the soil surface
at land plots allocated for construction of houses public buildings and industrial facilities
bull Measurements of radon concentration in soil air
Reference standards IEC 61577
SPC ldquoDozardquoRadiation monitoring equipment
76 77
UKPN-2M-D NEUTRON BEAM IRRADIATOR
Reference standards IEC 61005 61322
Calibration of neutron dose and dose rate meters
Calibration ofbull Ambient equivalent dose H(10) meters (Sv Svh)bull Personal equivalent dose Hp(10) meters (Sv Svh)bull Flux density of neutrons (cm-2∙s-1)bull Transfer container for temporary storage of
sources bull Red light signal of source working position
Physical carachteristicsRange of reproduced dose ratebull 20 divide 800 μSvh
Range of reproduced flux densitiesbull 10 divide 400 cm-2∙s-1
Type of a source in use bull Pu-Be
Activity of a source in usebull 24х1011 Bq (with density of 107 s-1)
Overall dimensions weight no morebull 3000x750x2000 mm 300 kg
Required room dimensionsbull not less than 7x3x3 m
Electrical characteristicsPower supply bull 220 V 50 Hz
Calibration of gamma dose and dose rate meters
Calibration ofbull Ambient equivalent dose H(10) meters (Sv Svh)bull Personal equivalent dose Hp(10) meters (Sv Svh)bull Exposure dose X meters (R Rh)bull Four sources in irradiator bull Select source and move to working position
return to storage position using special rodbull Transfer container for temporary storage of
sources bull Red light signal of source working position
UPGD-2M-DGAMMA BEAM IRRADIATOR
Physical characteristicsRange of reproduced dose rate bull 05 μSvh divide 50 mSvh (50 μRh divide 5 Rh)
Maximum activity of source bull 2times1011 Bq (50 Ci) Cs-137
Overall dimensionsbull Irradiator 800times500times500 mmbull Guide rails length 30 mbull Height 16 mbull Weight not more than 700 kgbull Required room dimensions not less than 7x3x3 m
Electrical characteristicsPower supply bull 220 V 50 Hz
UPGD-2M-D
Reference standards IEC 60846 IEC 61526 IEC 61066
SPC ldquoDozardquo
78 79
Contents
MEASURING UNITS
DBG-S11D wide range gamma area monitor 40
UDKS-100 gamma and X-ray area monitor 41
UDMN-100 neutron area monitor 41
ALARM UNITS
BAS-2 ldquoMICROrdquo external visual alarm 42
BZS-2 ldquoMicrordquo external audible alarm 42
Illuminated warning signs 43
ldquoImpulsrdquo external display unit 43
UIM-3D area monitor count rate meter 44
DKG-05D personal gamma dosimeter 46
DVS-02D gamma-neutron personal electronic dosimeter 47
DVGI-8D new pen-type personal ionization chamber dosimeters 48
DKG-02U ldquoARBITERrdquo wide range gamma-dosimeter 49
DKG-07D ldquoDROZDrdquo gamma-dosimeter 50
MKS-15D ldquoSNEGIRrdquo multi ndash purpose radiation survey meter 51
SRPS-05D gamma monitor 52
DOZA-TLD multipurpose TLD system 53
DKS-96 universal radiation survey meter 54
EXTERNAL PROBES ALPHA
Alpha BDZA-96 55
Alpha BDZA-96B 55
Alpha BDZA-96M 55
Alpha BDZA-96S 55
Alpha BDZA-96T 55
EXTERNAL PROBES BETA
Beta BDZB-96 56
Beta BDZB-99 56
Beta BDZB-96B 56
Beta BDZB-96S 56
EXTERNAL PROBES GAMMA
Gamma BDKS-96B 57
Gamma and beta BDKS-96S 57
Gamma BDMG-96 57
EXTERNAL PROBES GAMMA
Gamma-search BDVG-96 58
Gamma-search BDPG-96 58
ContentsRadiation monitoring systemldquoPELIKANrdquo Radiation monitoring system (RMS) 6
BDMG-101 high range gamma area monitor 10
DBG-S11D wide range gamma area monitor 11
BDRG-52 high range gamma area monitor for accident and post-accident conditions 12
UDGP-01 Liquid technological environments monitor 13
UDMN-100 neutron area monitor 14
UDKG-100 Wel Liquid gamma monitor 14
BOP-1M data processing and transmission unit 15
UDA-1AB particulate monitor 16
UDG-1B noble gas monitor 17
UDG-03D noble gas monitor 18
UDI-1B iodine monitor 19
UDGB-01 noble gasesH-3C-14 monitor 20
UDGP-01 steam generator leakage monitor 21
UPPVM air flow parameters monitor 22
ldquoIMPULSrdquo external display unit 23
BI-2 remote display amp alarm unit 24
BASBAS-1s external alarm 25
SKGAV stack monitor 26
RMS software 28
RMS workstation ndash operator console 29
Configurator software 29
RM RACK radiation monitoring rack 30
SRKS-01D criticality accident alarm system 32
ldquoATLANT-Mrdquo environmental radiation monitoring system 34
ldquoBREEZErdquo high-volume air sampler 35
ldquoGAMMA-SENSORrdquo gamma-survey system 36
Radiation monitoring equipmentAREA MONITOR ldquoFREGATrdquo 38
BPI-1D local display unit 39
80
Gamma-search BDPG-96M 58
Gamma BDKG-96 stainless steel casing for geologic applications well logging 59
EXTERNAL PROBES NEUTRON
Neutron BDMN-96 59
Neutron-search BDKN-96 59
RZB-05D Hand-foot-clothing monitor 60
RZBA-04-04M whole body contamination monitor 61
RZA-05D alpha hand-monitor 62
UMF-2000 low level alpha- beta- counter 63
DRK dose area product meter 64
ldquoPROGRESS-BETArdquo scintillation beta spectrometer 65
ldquoPROGRESS-GAMMArdquo scintillation gamma spectrometer 66
ldquoPROGRESS-G(P)rdquo portable scintillation gamma spectrometer 67
ldquoPROGRESS-ARrdquo alpha radiometer 68
ldquoPROGRESSrdquo whole body counter 69
MKG-01D ldquoSADOVNIKrdquo spectrometry system 70
MKS-01A ldquoMULTIRAD-ASrdquo alpha spectrometer 71
UCRV-2 airflow monitor 72
PVP-06 portable air sampler 73
ldquoALPHARAD PLUSrdquo radon thoron amp their progeny monitor 74
UPG-P desktop gamma beam irradiator 75
UPGD-2M-D gamma beam irradiator 76
UKPN-2M-D neutron beam irradiator 77
SPC ldquoDozardquoRadiation monitoring equipment
54 55
Continuous and pulsed gamma and X-ray dose H(10) and dose-rate measurementbull Alpha beta and gamma contamination surveybull Neutron dose H(10) and dose-rate measurementbull Gamma radiation flux density in boreholes and
liquid media measurement
Electrical characteristicsPower supply bull UIK-05 four C-size batteriesbull UIK-05-01 rechargeable batterybull UIK-06 rechargeable battery
Interfaces bull RS-232bull USB (via adapter)
bull Detector type automatic determination and corre-sponding measurement modes selection
bull Alarm threshold settings ndash for dose dose-rate alpha and beta contaminations
bull ldquoDetectrdquo and ldquoLocaterdquo modes for survey probes
Reference standards Nuclear IEC 60846 IEC 60325 IEC 61005 IEC 62363
Case
UIK-06 control unit165times78times48 mm 03 kg
DKS-96UNIVERSAL RADIATION SURVEY METER
UIK-05 control unit202times86times90 mm 10 kg
BDZA-96
BDZA-96B
BDZA-96M
BDZA-96S
BDZA-96T
EXTERNAL PROBES ALPHAALPHA BDZA-96Detector bull ZnS(Ag) 70 cm2
Measurement range (for Pu-239)bull 01 divide 104 min-1cm-2
Overall dimensions weightbull Oslash 130times240 mm 11 kg
ALPHA BDZA-96BDetector bull ZnS(Ag) 300 сm2
Measurement range (for Pu-239)bull 01 divide 2103 min-1cm-2
Overall dimensions weightbull Oslash 230times290 mm 40 kg
ALPHA BDZA-96MDetector bull ZnS(Ag) 10 сm2
Measurement range (for Pu-239)bull 01 divide 105 min-1cm-2
Overall dimensions weightbull Oslash 65times240 mm 09 kg
ALPHA BDZA-96SDetector bull ZnS(Ag) 30 сm2
Measurement range (for Pu-239)bull 01 divide 5104 min-1cm-2
Overall dimensions weightbull Oslash 90times240 mm 10 kg
ALPHA BDZA-96TDetector bull Silicon 5 сm2
Measurement range (for Pu-239)bull 01 divide 106 min-1cm-2
Overall dimensions weightbull Oslash 50times60 mm 015 kg
SPC ldquoDozardquoRadiation monitoring equipment
56 57
BETA BDZB-96Detector Scintillator 28 сm2
Measurement range (for Sr-90+Y-90)bull 10 divide 105 min-1cm-2
Energy rangebull 03 divide 30 MeV
Overall dimensions weightbull Oslash 90times230 mm 09 kg
BETA BDZB-99Detector bull GM counter 30 сm2
Measurement range (for Sr-90+Y-90)bull 20 divide 104 min-1см-2
Energy rangebull 012 divide 30 MeV
Overall dimensions weightbull Oslash 88times80 mm 04 kgbull Telescopic pole length 07 m
BETA BDZB-96BDetector bull GM counter 80 сm2
Measurement range (for Sr-90+Y-90)bull 3 divide 104 min-1сm-2
Energy rangebull 012 divide 30 MeV
Overall dimensions weightbull 150times200times110 mm 15 kg
BETA BDZB-96Sbull Detector GM counter 15 сm2
Measurement range (for Sr-90+Y-90)bull 10 divide 3104 min-1cm-2
Energy rangebull 012 divide 30 MeV
Overall dimensions weightbull Oslash 65times65 mm 03 kgbull Telescopic pole length 07 m
BDZB-96
BDZB-99
BDZB-96B
BDZB-96S
EXTERNAL PROBES BETA
GAMMA BDKS-96BDetector bull Tissue-equivalent scintillator Oslash 45times20 mm
Measurement rangebull Dose rate H(10) 01 μSvh divide 1 Svhbull Dose H(10) 01 μSv divide 10 Sv
Energy rangebull 0015 divide 10 MeV
Overall dimensions weightbull Oslash 60times250 mm 085 kg
GAMMA AND BETA BDKS-96SDetector bull Double GM counters
Measurement rangebull Gamma dose rate H(10) 01 μSvh divide 1 mSvhbull Gamma dose H(10) 01 μSv divide 10 Svbull Beta 10 divide 3104 min-1cm-2
Energy rangebull Gamma 005 divide 3 MeVbull Beta 012 divide 3 MeV
Overall dimensions weightbull Oslash 80times80 mm 035 kgbull Telescopic pole length 07 m
GAMMA BDMG-96Detector bull GM counters
Measurement rangebull Dose rate H(10) 01 μSvh divide 10 Svhbull Dose H(10) 01 μSv divide 10 Sv
Energy range bull 005 divide 3 MeV
Overall dimensions weightbull 40times250 mm 05 kgbull Telescopic pole length 07 m 4 m (by request)
EXTERNAL PROBES GAMMA
BDKS-96B
BDMG-96
BDKS-96S
SPC ldquoDozardquoRadiation monitoring equipment
58 59
GAMMA-SEARCH BDVG-96Detector bull Scintillator NaI(Tl) Oslash 63times63 mm
Measurement rangebull Flux density measurement range 4 divide 2000 s-1cm-2
bull Dose rate H(10) for Cs-137 01 divide 30 μSvhbull Sensitivity for Cs-137 3000 (pulsess-1)( μSvh-1)
Overall dimensions weightbull Oslash 88times400 mm 20 kgbull Modular pole length 16 m
GAMMA-SEARCH BDPG-96Detector bull Scintillator NaI(Tl) Oslash 25times40 mm
Measurement rangebull Flux density measurement range 10 divide 8000 s-1cm-2
bull Dose rate H(10) for Cs-137 01 divide 100 μSvhbull Sensitivity for Cs-137 500 (pulsess-1)( μSvh-1)
Overall dimensions weightbull 50times190times480 mm 10 kgbull Telescopic pole length 07 m
GAMMA-SEARCH BDPG-96MDetector bull Scintillator NaI(Tl) Oslash 18times30 mm
Measurement rangebull Flux density measurement range 10 divide 24000 s-1cm-2
bull Dose rate H(10) for Cs-137 01 divide 300 μSvhbull Sensitivity for Cs-137 200 (pulsess-1)( μSvh-1)
Overall dimensions weightbull Oslash 35times320 mm 05 kgbull Telescopic pole length 07 or 38 m
EXTERNAL PROBES GAMMA
BDVG-96
BDPG-96M
BDPG-96
EXTERNAL PROBESGAMMA BDKG-96 STAINLESS STEEL CASING FOR GEOLOGIC APPLICATIONS WELL LOGGINGDetector bull Scintillator NaI(Tl) Oslash 18times30 mm
Measurement rangebull Flux density measurement range 10 divide 105 s-1cm-2
bull Dose rate H(10) for Cs-137 5 divide 2104 μRhbull Sensitivity for Cs-137 200 (pulsess-1)( μSvh-1)
Overall dimensions weightbull Oslash 38times535 mm 36 kgbull Cable length 10 divide 1000 m
NEUTRON BDMN-96Detector bull Scintillator with ZnS(Ag)
Measurement rangebull Dose rate H(10) 01 μSvh divide 01 Svhbull Dose H(10) 01 μSv divide 10 Sv
Energy range bull 0025 eV divide 10 MeV
Overall dimensions weightbull Detector Oslash 54times200 mm 08 kgbull Moderator Oslash 245 mm 73 kg
NEUTRON-SEARCH BDKN-96Detector bull He-3 counter in polyethilene moderator
Measurement rangebull Dose rate H(10) for Pu-Be 01 μSvh divide 01 Svhbull Dose H(10) for Pu-Be 01 μSv divide 10 Sv
Energy range bull 0025 eV divide 14 MeV
Overall dimensions weightbull 295times142times100 mm 225 kg
BDKG-96M
BDMN-96
BDKN-96
SPC ldquoDozardquoRadiation monitoring equipment
60 61
bull No gas supply neededbull Clothing control detachable right hand detector bull Alpha detector optional connection bull Numeric and color (red green) indication of
control resultsbull LED sensor of hand-foot positioning for start of
measurementbull Automatic compensation of gamma background
and contamination of detectorbull Audible alarm signals of the excess of preset
thresholdsbull Measurement value indication min-1cm-2 or
Bqсm2
Reference standards Nuclear IEC 61098
RZB-05D HAND-FOOT-CLOTHING MONITOR
Physical characteristicsDetectors bull Gamma beta - GM countersbull Alpha - scintillatior ZnS(Ag)
Detecting nuclidesbull Alpha Pu-239 U-234 U-238bull Beta Sr-90+Y-90 F-18 Cs-137 Co-60 Tс-99 O-15
N-13 Sr-89 C-11 I-131 Na-22 Ru-106+Rh-106 Tl-204
bull Gamma Tc-99m I-123
Efficiencybull Alpha
Pu-239 40 U-234 25U-238 15
bull Beta Sr-90 +Y-90 40
Measurement range bull Alpha 1 divide 103 min-1cm-2 bull Beta 10 divide 103 min-1cm-2
bull Gamma 5103 divide 5106 min-1cm-2
Energy range bull Alpha 30 divide 80 MeV bull Beta 008 divide 35 MeV bull Gamma 005 divide 30 MeV
Operation temperature range bull Minus 10 divide +50 ordmС
Electrical characteristicsbull Power supply 220 V 50 Hz
Mechanical characteristicsOverall dimensions weight bull 740times750times1180 mm 45 kg
Versionsbull Withwithout alpha detectorbull Indication (min-1cm-2 ) or (Bqсm2)bull Detectors overall dimensions smbull Hand 178 х 235bull Foot 185 х 436
Whole body contamination monitor RZBA-04-04Mbull No gas supply neededbull Compensation for background gamma radiation
and contamination of detector unitsbull Individual threshold setting for each measure-
ment channelbull Visible and audible alarms ldquoCONTAMINATIONrdquo and
ldquoCLEANrdquo bull Indication of contaminated body parts on the
panel with image of the bodybull Optional remote alpha-detector
Physical characteristicsDetectors bull Beta - GM counters scintillatorsbull Alpha - scintillatior ZnS(Ag)
Measurement range bull Beta 5 divide 15000 min-1cm-2
bull Alpha 01 divide 10000 min-1cm-2
Energy range bull Beta 015 divide 25 MeV bull Alpha 40 divide 56 MeV
Operation temperature range bull +5 divide +50 ordmС
Electrical characteristicsPower supply bull 220 V 50 Hz
Interfaces bull RS-232bull RS-485
Mechanical characteristicsOverall dimensions weight bull 2650times940times930 mm 310 kg
Versionsbull Withwithout alpha detectorbull Indication (min-1cm-2 ) or (Bqсm2)
Reference standards Nuclear IEC 61098
RZBA-04-04MWHOLE BODY CONTAMINATION MONITOR
SPC ldquoDozardquoRadiation monitoring equipment
62 63
RZA-05DALPHA HAND-MONITOR
bull No gas supply needed bull Numeric and color (red green) indication of
control resultsbull LED sensor of hand- positioning for start of
measurementbull Audible alarm signals of the excess of preset
thresholdsbull Measurement value indication min-1cm-2 or
Bqсm2
Physical characteristicsDetectors alpha - scintillatior ZnS(Ag)
Efficiencybull Pu-239 20 bull U-234 14bull U-238 8
Measurement range bull 05 divide 105 min-1cm-2
Energy range bull 41 divide 90 MeV
Operation temperature range bull minus 10 divide +50 ordmС
Electrical characteristicsPower supply bull 220 V 50 Hz
Mechanical characteristicsOverall dimensions weight no more bull 740times1400times1450 mm 70 kg
Reference standards Nuclear IEC 61098
bull Simultaneous measurement of alphabeta activi-ties in the sample
bull Active shielding anti-coincidence background subtraction using GM counters
bull Lead shielding 30 mm
UMF-2000 LOW LEVEL ALPHA- BETA- COUNTER
Physical characteristicsDetectors bull Silicon specrometric detector 500 or 1000 mm2
Measurement range bull Alpha 001 divide 1000 Bq bull Beta 01 divide 3000 Bq
Energy range bull Alpha 35 divide 80 MeV bull Beta 005 divide 35 MeV
Electrical characteristicsPower supply bull 220 V 50 Hz
Interfaces bull RS-232bull USB
Mechanical characteristicsOverall dimensions weight bull 337times286times190 mm 22 kg
Versionsbull Detector area 500 mm2
bull Detector area 1000 mm2
UMF-2000 Detector area 1000 mm2
UMF-2000 Detector area 500 mm2
SpectraDec software for alpha-spectrometric measurements
SPC ldquoDozardquoRadiation monitoring equipment
64 65
DRK DOSE AREA PRODUCT METER
DRK-1bull Diagnostic reference level (DRL) of patients
determinationbull Suitable for all basic types of x-ray machines
Physical characteristicsDetector bull Plane-parallel ionization chamber
Measurement range bull 1 divide 104 cGycm2
Electrical characteristicsPower supply bull 220 V 50 Hz
DRK-1M-CTbull Measuring of dose length product
Physical characteristicsDetector bull Pencil Ionization Chamber
Measurement rangebull 05 divide 109 microGym
DRK-1Mbull Measuring of air kerma on sectional area of the
X-ray beam productbull Measuring of air kerma rate on area productbull Measuring of air kerma ratebull Measuring of air kerma
Physical characteristicsDetector bull Plane-parallel ionization chamber
Measurement rangebull 01 divide 109 microGym2
bull 06 divide 6104 microGym2cbull 30 divide 9105 microGycbull 30 divide 9991011 microGyReference standard IEC 60580 2003
bull Measurement of strontium-90 in the foodstuffs agricultural products etc
bull Measurement of gross beta activity in samplebull Self tests using built-in LED
ldquoPROGRESS-BETArdquo SCINTILLATION BETA SPECTROMETER
Physical characteristicsDetector bull Plastic scintillator Oslash70x10 mm
Sample bull Plate Oslash70 mmbull Weight up to 15 g
Energy range bull 02 divide 30 MeV
Minimum detectable activity of Sr-90 in a 10 g sample on a standard planchet Bqsamplebull In case of absence of K-40 in the sample 01 Bqbull In case the activity of K-40 till 5 Bqg 05 Bq
Electrical characteristics Interface bull USB
Mechanical characteristicsWeight bull No more 50 kg
Complete setBasic complete setbull Detector unit with plastic scintillator integrated
power supply amplifier ADC bull Lead shielding bull ldquoProgressrdquo software bull Сheck source for energetic calibration (Sr-90-Y-90) bull Planchet Oslash 70 mm (5 items) bull Sample dencification device bull Procedure manual for measurement of radio-
nuclidesrsquo activity using the scintillation beta spec-trometer ldquoProgressrdquo
Optional equipment and servicebull Personal computer and printer bull Calibrations for radionuclides not included in the
main library of radionuclides
Progress-Beta
Reference standards IEC 61562
SPC ldquoDozardquoRadiation monitoring equipment
66 67
bull Measurement of gamma activity in foodstuffs soil samples and others environmental objects
bull Identification of radionuclides in the sample bull Automatic correction for sample density bull Self-tests using built-in LED
ldquoPROGRESS-GAMMArdquoSCINTILLATION GAMMA SPECTROMETER
Physical characteristicsDetector bull NaI (Tl) Oslash63times63 mm
Validated measurement geometries bull Marinelli beakers (1 liter) Petri dishes (Oslash90 mm)
etc
Energy range bull 02 divide 30 MeV
Minimum detectable activity Bqsamplebull Cs-137 3 Bqbull Th-232 7 Bqbull Ra-226 8 Bq bull К-40 40 Bq
Electrical characteristics Interface bull USB
Mechanical characteristicsWeight bull No more 120 kg
Complete setBasic complete setbull Scintillation detector unit with NaI (Tl) detector
with integrated power supply amplifier and ADC bull Lead shielding 50 mm bull ldquoProgressrdquo software bull Сheck source for energy calibration (Cs-137 +
K-40)bull Marinelli beakers - 1 liter (5 items) bull Petri dishes Oslash 90 mm (5 items) bull Procedure manual for measurement of activity
of radionuclides using the scintillation gamma spectrometer ldquoProgressrdquo
Optional equipment and servicebull Kit for radon measurements including calibration
of ldquoIC-63rdquo geometry for counting the charcoal samples
bull Personal computer and printer bull Calibrations for user defined geometries bull Calibrations for radionuclides not included in the
main library of radionuclides
Progress-Gamma
Reference standards IEC 61563
ldquoPROGRESS-G(P)rdquoPORTABLE SCINTILLATION GAMMA SPECTROMETERbull Field measurements of gamma activity in environ-
mental objects without sampling (4π geometry)bull Laboratory measurement of gamma activity in
foodstuffs soil samples and others environmental objects
bull Identification of radionuclides in the sample bull Automatic correction for sample densitybull Tests using built-in LED
Physical charachteristicsDetector bull NaI (Tl) Oslash45times50 mmbull Lead shielding 20 mm
Validated measurement geometries bull Marinelli beakers (05 liter) Petri dishes (Oslash90 mm)
etc
Energy range bull 02 divide 30 MeV
Minimum detectable activity in 05-litre Marinelli beaker bull Cs-13710 Bqkgbull К-40100 Bqkgbull Ra-22618 Bqkg bull Th-23216 Bqkg
Minimum detectable activity in 30 min (4π geometry) bull Cs-137 2 Bqkgbull К-40 30 Bqkgbull Ra-226 4 Bqkg bull Th-232 3 Bqkg
Electrical characteristicsPower supply bull Rechargeable batterybull 220 V 50 Hz
Interface bull USB RS-232
Weight bull No more than 60 kg
Complete setBasic complete setbull Scinttillation detector unit with NaI(Tl) bull ldquoProgressrdquo softwarebull Сontrol unit ldquoSputnikrdquo for aquisition and analisys
of spectra with built-in memory for spectral databull Casebull Lead shielding (2 cm) for laboratory usebull 05-litre Marinelli beakers ndash 5 itemsbull Na-22 check sourcebull Power adapter BPS-01bull Operation manualbull Procedure manual for measurement of activity
of radionuclides using the scintillation gamma spectrometer ldquoProgressrdquo
Optional equipment and servicebull Kit for radon measurements with charcoalbull Built-in dose rate meterbull Additional memory (RAM) for storage of 64
spectrabull Additional power adapterbull Notebook and printer
Progress-Gamma
Reference standards IEC 61563
SPC ldquoDozardquoRadiation monitoring equipment
68 69
Physical characteristicsDetectorbull Scintillation detector ZnS (Oslash 60 mm)
Samplebull Thin sample - diameter up to 70 mm bull Preparation technique - electro-depositionbull Thick sample - diameter 70 mm weight
200300 mg bull Preparation technique - application of powders
(prepared by radiochemical concentration by water evaporation or by pounding of mineral samples) onto a planchet with the help of spirit
Energy rangebull 15 divide 8 MeV
Minimum detectable activitybull Thin samples no more than 910-3 Bqsamplebull Thick samples no more than 180 Bqkg
Mechanical characteristicsOverall dimensions weightbull 195times120times210 mm 34 kg
Complete setBasic complete setbull Alpha radiometer ldquoProgress-ARrdquobull Check source (uranium isotopes)
Set of accessoriesbull Procedure manual for measurements of radi-
oactivity using scintillation alpha radiometer ldquoProgress-ARrdquo
bull ldquoProgressrdquo software
ldquoProgress-ARrdquo
bull Measurement of gross activity of alpha emitting radionuclides in thin samples
bull Measurement of gross activity of alpha emitting radionuclides in thick samples
bull Measurement of activity deposited on aerosol filters
ldquoPROGRESS-ARrdquoALPHA RADIOMETER
Several fixed positions of the detector enable to perform measurements in various geometries and to estimate the content ofbull Cs-137 in the whole bodybull I-131 in thyroidbull Co-60 Cs-137 Mn-54 Cr-51 in lungsbull Database for storage of measurement data and
resultsbull Uncertainty calculations based on measurement
databull Self tests using built-in LED
ldquoPROGRESSrdquo WHOLE BODY COUNTER
Physical characteristicsDetectorbull scintillation detector NaI (Tl) Oslash63times63 mm
Energy rangebull 02 divide 28 MeV
Minimum detectable activitybull By Cs-137 in the whole body - 1200 Bqbull By I-131 in thyroid - 100 Bqbull By Co-60 Cs-137 Mn-54 Cr-51 in lungs - 200 Bq
Mechanical characteristicsWeight bull No more than 120 kg
Complete setBasic complete setbull Collimator with rotator and holderbull Detector with incorporated ADCbull Patient chair and table for collimatorbull Check source Na-22bull Procedure manual for lifetime measurement of
gamma-emitting radionuclidesrsquo activity in human body using the gamma-spectrometer of human radiation ldquoProgressrdquo
bull laquoProgressraquo software
Optional equipment and servicebull Program of internal radiation committed internal
radiation effective dose calculation by the stand-ard model
bull Background phantombull Personal computer and printer
Collimator with rotator and holder
SPC ldquoDozardquoRadiation monitoring equipment
70 71
bull Categorization of wastes for the purpose of fur-ther processing including wastes with unknown radionuclide composition
bull Measurements during the incoming waste inspec-tion (accepting for storage disposal)
bull Certification of unconditioned and conditioned wastes in closed containers without opening them (at nuclear plants or at facilities providing collection storage transportation conditioning processing temporal storage and final disposal of radioactive waste)
bull Activity measurement of extended objects in situ without opening the equipment
bull Activity measurement of extended objects after opening (for example assessment of tubes used for oil transportation)
MKG-01D ldquoSADOVNIKrdquoSPECTROMETRY SYSTEM
Physical charachteristicsDetectorbull Detector unit GEM (GMX) with HPGe detector and
multi-positioning cryostat CFG-PMOD4-7 with 7 litre Dewar
bull Dose rate probe BDMG-200
Energy range bull With GEM detector 004 divide 30 MeVbull With GMX detector 0005 divide 15 MeVbull Dose rate probe BDMG-200 ndash 005 divide 30 MeV
Measurement rangebull 110-7 divide 10 Svhbull Relative efficiency of detection (in photopeak) at
13325 MeV (Co-60) 10 divide 150
Electrical characteristicsPower supplybull 220 V 50 Hz
Interfacebull USB
Complete setBasic complete setbull Spectrometric detector unit GEM (GMX) with
HPGe detector and multi-positioning cryostat with 7 litre Dewar
bull Portable digital multichannel analyzer DigiDARTbull Dose rate probe BDMG-200bull Autonomous power supply unit with built-in
batterybull Industrial computer keyboardbull Laser range-finderbull Thermographic printerbull Web-camerabull Device equipped with stepper motor for position-
ing of the spectrometric detectorbull Calibration device with reference sources
(Am-241 Co-60 Ba-133 Eu-152) for energy calibration
bull Removable collimators with end capbull Measurement proceduresbull ldquoClasterrdquo software
bull Measurement of gross alpha activity of alpha-emitting radionuclides
bull Measurement of alpha-emitting radionuclides activity in thin-layer samples meeting alpha-spectrometry requirements
Physical characteristicsDetectorbull Silicon ion-implanted 450 mm2
bull Easy to decontaminate thin windowbull dead layer less than 015 μmbull Background count rate in the range 3 divide 9 MeVbull No more than 09 h-1cm-2 for 450 mm2 detector
Energy rangebull 2 divide 9 MeVbull Lower limit of measurement range (minimum
detectable activity) 01 Bqbull Background count rate no more than 100 counts
in 24 hours
Electrical characteristics Power supplybull 220 V 50 Hz
Interfacebull USB
Complete setBasic complete setbull Detector unit with vacuum measuring chamber
and vacuum control systembull Low noise vacuum pump (type 2FY-05B or
equivalent)bull Check sourcebull ldquoProgressrdquo softwarebull Vacuum tube
MKS-01A ldquoMULTIRAD-ASrdquoALPHA SPECTROMETER
SPC ldquoDozardquoRadiation monitoring equipment
72 73
UCRV-2AIRFLOW MONITOR
bull Monitor of the air flow through filter of centralized multichannel sampling system
bull Radiation monitoring system (RMS) integration for internal exposures determination
bull Volume and flow rate measurements of the air that have passed through a analytical filter
bull Bar-code for filter identificationbull Operation as either standalone unit or as a part of
the RMS
Physical characteristicsMeasurement range of air volume bull 001 divide 9999 m3
Operation temperature range bull minus 20 divide +50 ordmС
Electrical characteristicsPower supply bull 220 V 50 Hz
Interface bull RS-485
PVP-06PORTABLE AIR SAMPLER
Air Sampler PVP-06 is indispensable for monitoring the radiation situation where the concentration of radioactive aerosols in the air does not require a sta-tionary sampling equipment Sampling head PVP-06 provides easy change of filters and cartridges
Purposebull To monitor the concentration of radioactive aero-
sols in the air sites
Controlled aerosolsbull Alpha- and beta-active aerosolsbull Daughter products of decay of radon and thoronbull Iodine isotopes
Physical characteristicsTypes of filtersbull Aerosol AFA-RSP-20bull Iodine AFA SI-20
Flow rate bull 33∙10-4 ndash 233∙10-4 m3s (20 divide 140 l min)
Electrical characteristicsPower supply bull 220 V50 Hzbull The vehicle power supply 108 divide 145 Vbull Internal battery
Minimal working time on internal battery to recharge bull 8 hours
Power consumption (at a flow rate of 100 lmin) bull 40 VA
Environment characteristicsOperating temperature bull minus 10 divide +40 deg C
Maximum humidity bull 90
Pressure bull 860 to 1060 hPA
Noise generated by the pump bull lt 55 dBA at 1 m
Mechanical characteristicsDimensions weight bull 241 times 108 times 160 mm 28 kg
Case material bull Plastic
Complete setbull Air sampler PVP-06bull AC power adapterbull Filters AFA-RSP-20 - 100 pcsbull Packaging for filters - 40 pcsbull Casebull Operation manualbull Calibration certificate
Optional equimpient bull Kit for sampling sorption columns of activated
carbon Ř head of sorption columns with protective
covers Ř activated charcoal SKT-3 - 1 pkg (02 L) Ř charocoal samples SC-13 - 8 pcs
bull Car charger bull Tipod bull Shoulder strapbull Calibration stand bull Filters AFA SI-20 - 100 pcs
Consumablesbull Aerosol filters AFA RSP-20bull Iodine filters AFA SI-20
SPC ldquoDozardquoRadiation monitoring equipment
74 75
Calibration of gamma dose and dose rate meters
Calibration ofbull Ambient equivalent dose H(10) meters (Sv Svh)bull Personal equivalent dose Hp(10) meters (Sv Svh)bull Exposure dose X meters (R Rh)bull Two sources in irradiator bull Select source and collimator opening using
tumbler
UPG-P DESKTOP GAMMA BEAM IRRADIATOR
Physical characteristicsRange of reproduced dose rate bull 05 μSvh divide 10 mSvh (50 μRh divide 100 mRh)
Sources activities bull 6times106 6times108 Bq (02 20 mCi) Cs-137
Overall dimensions bull 1250times400times300 mm
Irradiator weight bull Not more than 37 kg
Calibration bench weight bull Not more than 15 kg
Reference standards IEC 60846 IEC 61526
Physical characteristicsDetectorbull Silicon
Measurement range EEC measurement bull Measurement range of radon EEC
10 divide 10bull106 Bqbullm-3
bull Measurement range of thoron EEC 05 divide 10bull104 Bqbullm-3
bull Air flow through the filter 100plusmn05 lmin
Concentration measurementbull Measurement range of radon-222 concentration
in air 10 divide 20bull106 cpsbull Measurement range of 216Po(ThA)
1bull10-3 divide 1bull102 cpsbull Air sampler flow rate
10plusmn02 lminbull Measurement range of radon-222 concentration
in water samples 6 divide 800 Bqbullkg-1
bull Measurement range of radon-222 flux from soil surface 20 divide 103 mBqsbullm2
bull Measurement range of radon-222 concentration with preliminary sampling of air using air sam-plers 20 divide 107 Bqbullm-3
bull Measurement range of radon-222 concentration in samples of soil air 103 divide 106 Bqbullm-3
Operation temperature range bull 1 divide 35 ordmC
Electrical characteristicsPower supply bull 80 VA
Mechanical characteristicsOverall dimensions weight bull 220times200times165 mm 36 kg
ldquoALPHARAD PLUSrdquoRADON THORON amp THEIR PROGENY MONITORbull Measurement of radon and thoron concentration
and effective equivalent concentration (EEC)bull In the airbull In the indoor air of residential public and industri-
al buildings and structuresbull Measurement of radon in drinking water sourcesbull Measurements of radon flux from the soil surface
at land plots allocated for construction of houses public buildings and industrial facilities
bull Measurements of radon concentration in soil air
Reference standards IEC 61577
SPC ldquoDozardquoRadiation monitoring equipment
76 77
UKPN-2M-D NEUTRON BEAM IRRADIATOR
Reference standards IEC 61005 61322
Calibration of neutron dose and dose rate meters
Calibration ofbull Ambient equivalent dose H(10) meters (Sv Svh)bull Personal equivalent dose Hp(10) meters (Sv Svh)bull Flux density of neutrons (cm-2∙s-1)bull Transfer container for temporary storage of
sources bull Red light signal of source working position
Physical carachteristicsRange of reproduced dose ratebull 20 divide 800 μSvh
Range of reproduced flux densitiesbull 10 divide 400 cm-2∙s-1
Type of a source in use bull Pu-Be
Activity of a source in usebull 24х1011 Bq (with density of 107 s-1)
Overall dimensions weight no morebull 3000x750x2000 mm 300 kg
Required room dimensionsbull not less than 7x3x3 m
Electrical characteristicsPower supply bull 220 V 50 Hz
Calibration of gamma dose and dose rate meters
Calibration ofbull Ambient equivalent dose H(10) meters (Sv Svh)bull Personal equivalent dose Hp(10) meters (Sv Svh)bull Exposure dose X meters (R Rh)bull Four sources in irradiator bull Select source and move to working position
return to storage position using special rodbull Transfer container for temporary storage of
sources bull Red light signal of source working position
UPGD-2M-DGAMMA BEAM IRRADIATOR
Physical characteristicsRange of reproduced dose rate bull 05 μSvh divide 50 mSvh (50 μRh divide 5 Rh)
Maximum activity of source bull 2times1011 Bq (50 Ci) Cs-137
Overall dimensionsbull Irradiator 800times500times500 mmbull Guide rails length 30 mbull Height 16 mbull Weight not more than 700 kgbull Required room dimensions not less than 7x3x3 m
Electrical characteristicsPower supply bull 220 V 50 Hz
UPGD-2M-D
Reference standards IEC 60846 IEC 61526 IEC 61066
SPC ldquoDozardquo
78 79
Contents
MEASURING UNITS
DBG-S11D wide range gamma area monitor 40
UDKS-100 gamma and X-ray area monitor 41
UDMN-100 neutron area monitor 41
ALARM UNITS
BAS-2 ldquoMICROrdquo external visual alarm 42
BZS-2 ldquoMicrordquo external audible alarm 42
Illuminated warning signs 43
ldquoImpulsrdquo external display unit 43
UIM-3D area monitor count rate meter 44
DKG-05D personal gamma dosimeter 46
DVS-02D gamma-neutron personal electronic dosimeter 47
DVGI-8D new pen-type personal ionization chamber dosimeters 48
DKG-02U ldquoARBITERrdquo wide range gamma-dosimeter 49
DKG-07D ldquoDROZDrdquo gamma-dosimeter 50
MKS-15D ldquoSNEGIRrdquo multi ndash purpose radiation survey meter 51
SRPS-05D gamma monitor 52
DOZA-TLD multipurpose TLD system 53
DKS-96 universal radiation survey meter 54
EXTERNAL PROBES ALPHA
Alpha BDZA-96 55
Alpha BDZA-96B 55
Alpha BDZA-96M 55
Alpha BDZA-96S 55
Alpha BDZA-96T 55
EXTERNAL PROBES BETA
Beta BDZB-96 56
Beta BDZB-99 56
Beta BDZB-96B 56
Beta BDZB-96S 56
EXTERNAL PROBES GAMMA
Gamma BDKS-96B 57
Gamma and beta BDKS-96S 57
Gamma BDMG-96 57
EXTERNAL PROBES GAMMA
Gamma-search BDVG-96 58
Gamma-search BDPG-96 58
ContentsRadiation monitoring systemldquoPELIKANrdquo Radiation monitoring system (RMS) 6
BDMG-101 high range gamma area monitor 10
DBG-S11D wide range gamma area monitor 11
BDRG-52 high range gamma area monitor for accident and post-accident conditions 12
UDGP-01 Liquid technological environments monitor 13
UDMN-100 neutron area monitor 14
UDKG-100 Wel Liquid gamma monitor 14
BOP-1M data processing and transmission unit 15
UDA-1AB particulate monitor 16
UDG-1B noble gas monitor 17
UDG-03D noble gas monitor 18
UDI-1B iodine monitor 19
UDGB-01 noble gasesH-3C-14 monitor 20
UDGP-01 steam generator leakage monitor 21
UPPVM air flow parameters monitor 22
ldquoIMPULSrdquo external display unit 23
BI-2 remote display amp alarm unit 24
BASBAS-1s external alarm 25
SKGAV stack monitor 26
RMS software 28
RMS workstation ndash operator console 29
Configurator software 29
RM RACK radiation monitoring rack 30
SRKS-01D criticality accident alarm system 32
ldquoATLANT-Mrdquo environmental radiation monitoring system 34
ldquoBREEZErdquo high-volume air sampler 35
ldquoGAMMA-SENSORrdquo gamma-survey system 36
Radiation monitoring equipmentAREA MONITOR ldquoFREGATrdquo 38
BPI-1D local display unit 39
80
Gamma-search BDPG-96M 58
Gamma BDKG-96 stainless steel casing for geologic applications well logging 59
EXTERNAL PROBES NEUTRON
Neutron BDMN-96 59
Neutron-search BDKN-96 59
RZB-05D Hand-foot-clothing monitor 60
RZBA-04-04M whole body contamination monitor 61
RZA-05D alpha hand-monitor 62
UMF-2000 low level alpha- beta- counter 63
DRK dose area product meter 64
ldquoPROGRESS-BETArdquo scintillation beta spectrometer 65
ldquoPROGRESS-GAMMArdquo scintillation gamma spectrometer 66
ldquoPROGRESS-G(P)rdquo portable scintillation gamma spectrometer 67
ldquoPROGRESS-ARrdquo alpha radiometer 68
ldquoPROGRESSrdquo whole body counter 69
MKG-01D ldquoSADOVNIKrdquo spectrometry system 70
MKS-01A ldquoMULTIRAD-ASrdquo alpha spectrometer 71
UCRV-2 airflow monitor 72
PVP-06 portable air sampler 73
ldquoALPHARAD PLUSrdquo radon thoron amp their progeny monitor 74
UPG-P desktop gamma beam irradiator 75
UPGD-2M-D gamma beam irradiator 76
UKPN-2M-D neutron beam irradiator 77
SPC ldquoDozardquoRadiation monitoring equipment
56 57
BETA BDZB-96Detector Scintillator 28 сm2
Measurement range (for Sr-90+Y-90)bull 10 divide 105 min-1cm-2
Energy rangebull 03 divide 30 MeV
Overall dimensions weightbull Oslash 90times230 mm 09 kg
BETA BDZB-99Detector bull GM counter 30 сm2
Measurement range (for Sr-90+Y-90)bull 20 divide 104 min-1см-2
Energy rangebull 012 divide 30 MeV
Overall dimensions weightbull Oslash 88times80 mm 04 kgbull Telescopic pole length 07 m
BETA BDZB-96BDetector bull GM counter 80 сm2
Measurement range (for Sr-90+Y-90)bull 3 divide 104 min-1сm-2
Energy rangebull 012 divide 30 MeV
Overall dimensions weightbull 150times200times110 mm 15 kg
BETA BDZB-96Sbull Detector GM counter 15 сm2
Measurement range (for Sr-90+Y-90)bull 10 divide 3104 min-1cm-2
Energy rangebull 012 divide 30 MeV
Overall dimensions weightbull Oslash 65times65 mm 03 kgbull Telescopic pole length 07 m
BDZB-96
BDZB-99
BDZB-96B
BDZB-96S
EXTERNAL PROBES BETA
GAMMA BDKS-96BDetector bull Tissue-equivalent scintillator Oslash 45times20 mm
Measurement rangebull Dose rate H(10) 01 μSvh divide 1 Svhbull Dose H(10) 01 μSv divide 10 Sv
Energy rangebull 0015 divide 10 MeV
Overall dimensions weightbull Oslash 60times250 mm 085 kg
GAMMA AND BETA BDKS-96SDetector bull Double GM counters
Measurement rangebull Gamma dose rate H(10) 01 μSvh divide 1 mSvhbull Gamma dose H(10) 01 μSv divide 10 Svbull Beta 10 divide 3104 min-1cm-2
Energy rangebull Gamma 005 divide 3 MeVbull Beta 012 divide 3 MeV
Overall dimensions weightbull Oslash 80times80 mm 035 kgbull Telescopic pole length 07 m
GAMMA BDMG-96Detector bull GM counters
Measurement rangebull Dose rate H(10) 01 μSvh divide 10 Svhbull Dose H(10) 01 μSv divide 10 Sv
Energy range bull 005 divide 3 MeV
Overall dimensions weightbull 40times250 mm 05 kgbull Telescopic pole length 07 m 4 m (by request)
EXTERNAL PROBES GAMMA
BDKS-96B
BDMG-96
BDKS-96S
SPC ldquoDozardquoRadiation monitoring equipment
58 59
GAMMA-SEARCH BDVG-96Detector bull Scintillator NaI(Tl) Oslash 63times63 mm
Measurement rangebull Flux density measurement range 4 divide 2000 s-1cm-2
bull Dose rate H(10) for Cs-137 01 divide 30 μSvhbull Sensitivity for Cs-137 3000 (pulsess-1)( μSvh-1)
Overall dimensions weightbull Oslash 88times400 mm 20 kgbull Modular pole length 16 m
GAMMA-SEARCH BDPG-96Detector bull Scintillator NaI(Tl) Oslash 25times40 mm
Measurement rangebull Flux density measurement range 10 divide 8000 s-1cm-2
bull Dose rate H(10) for Cs-137 01 divide 100 μSvhbull Sensitivity for Cs-137 500 (pulsess-1)( μSvh-1)
Overall dimensions weightbull 50times190times480 mm 10 kgbull Telescopic pole length 07 m
GAMMA-SEARCH BDPG-96MDetector bull Scintillator NaI(Tl) Oslash 18times30 mm
Measurement rangebull Flux density measurement range 10 divide 24000 s-1cm-2
bull Dose rate H(10) for Cs-137 01 divide 300 μSvhbull Sensitivity for Cs-137 200 (pulsess-1)( μSvh-1)
Overall dimensions weightbull Oslash 35times320 mm 05 kgbull Telescopic pole length 07 or 38 m
EXTERNAL PROBES GAMMA
BDVG-96
BDPG-96M
BDPG-96
EXTERNAL PROBESGAMMA BDKG-96 STAINLESS STEEL CASING FOR GEOLOGIC APPLICATIONS WELL LOGGINGDetector bull Scintillator NaI(Tl) Oslash 18times30 mm
Measurement rangebull Flux density measurement range 10 divide 105 s-1cm-2
bull Dose rate H(10) for Cs-137 5 divide 2104 μRhbull Sensitivity for Cs-137 200 (pulsess-1)( μSvh-1)
Overall dimensions weightbull Oslash 38times535 mm 36 kgbull Cable length 10 divide 1000 m
NEUTRON BDMN-96Detector bull Scintillator with ZnS(Ag)
Measurement rangebull Dose rate H(10) 01 μSvh divide 01 Svhbull Dose H(10) 01 μSv divide 10 Sv
Energy range bull 0025 eV divide 10 MeV
Overall dimensions weightbull Detector Oslash 54times200 mm 08 kgbull Moderator Oslash 245 mm 73 kg
NEUTRON-SEARCH BDKN-96Detector bull He-3 counter in polyethilene moderator
Measurement rangebull Dose rate H(10) for Pu-Be 01 μSvh divide 01 Svhbull Dose H(10) for Pu-Be 01 μSv divide 10 Sv
Energy range bull 0025 eV divide 14 MeV
Overall dimensions weightbull 295times142times100 mm 225 kg
BDKG-96M
BDMN-96
BDKN-96
SPC ldquoDozardquoRadiation monitoring equipment
60 61
bull No gas supply neededbull Clothing control detachable right hand detector bull Alpha detector optional connection bull Numeric and color (red green) indication of
control resultsbull LED sensor of hand-foot positioning for start of
measurementbull Automatic compensation of gamma background
and contamination of detectorbull Audible alarm signals of the excess of preset
thresholdsbull Measurement value indication min-1cm-2 or
Bqсm2
Reference standards Nuclear IEC 61098
RZB-05D HAND-FOOT-CLOTHING MONITOR
Physical characteristicsDetectors bull Gamma beta - GM countersbull Alpha - scintillatior ZnS(Ag)
Detecting nuclidesbull Alpha Pu-239 U-234 U-238bull Beta Sr-90+Y-90 F-18 Cs-137 Co-60 Tс-99 O-15
N-13 Sr-89 C-11 I-131 Na-22 Ru-106+Rh-106 Tl-204
bull Gamma Tc-99m I-123
Efficiencybull Alpha
Pu-239 40 U-234 25U-238 15
bull Beta Sr-90 +Y-90 40
Measurement range bull Alpha 1 divide 103 min-1cm-2 bull Beta 10 divide 103 min-1cm-2
bull Gamma 5103 divide 5106 min-1cm-2
Energy range bull Alpha 30 divide 80 MeV bull Beta 008 divide 35 MeV bull Gamma 005 divide 30 MeV
Operation temperature range bull Minus 10 divide +50 ordmС
Electrical characteristicsbull Power supply 220 V 50 Hz
Mechanical characteristicsOverall dimensions weight bull 740times750times1180 mm 45 kg
Versionsbull Withwithout alpha detectorbull Indication (min-1cm-2 ) or (Bqсm2)bull Detectors overall dimensions smbull Hand 178 х 235bull Foot 185 х 436
Whole body contamination monitor RZBA-04-04Mbull No gas supply neededbull Compensation for background gamma radiation
and contamination of detector unitsbull Individual threshold setting for each measure-
ment channelbull Visible and audible alarms ldquoCONTAMINATIONrdquo and
ldquoCLEANrdquo bull Indication of contaminated body parts on the
panel with image of the bodybull Optional remote alpha-detector
Physical characteristicsDetectors bull Beta - GM counters scintillatorsbull Alpha - scintillatior ZnS(Ag)
Measurement range bull Beta 5 divide 15000 min-1cm-2
bull Alpha 01 divide 10000 min-1cm-2
Energy range bull Beta 015 divide 25 MeV bull Alpha 40 divide 56 MeV
Operation temperature range bull +5 divide +50 ordmС
Electrical characteristicsPower supply bull 220 V 50 Hz
Interfaces bull RS-232bull RS-485
Mechanical characteristicsOverall dimensions weight bull 2650times940times930 mm 310 kg
Versionsbull Withwithout alpha detectorbull Indication (min-1cm-2 ) or (Bqсm2)
Reference standards Nuclear IEC 61098
RZBA-04-04MWHOLE BODY CONTAMINATION MONITOR
SPC ldquoDozardquoRadiation monitoring equipment
62 63
RZA-05DALPHA HAND-MONITOR
bull No gas supply needed bull Numeric and color (red green) indication of
control resultsbull LED sensor of hand- positioning for start of
measurementbull Audible alarm signals of the excess of preset
thresholdsbull Measurement value indication min-1cm-2 or
Bqсm2
Physical characteristicsDetectors alpha - scintillatior ZnS(Ag)
Efficiencybull Pu-239 20 bull U-234 14bull U-238 8
Measurement range bull 05 divide 105 min-1cm-2
Energy range bull 41 divide 90 MeV
Operation temperature range bull minus 10 divide +50 ordmС
Electrical characteristicsPower supply bull 220 V 50 Hz
Mechanical characteristicsOverall dimensions weight no more bull 740times1400times1450 mm 70 kg
Reference standards Nuclear IEC 61098
bull Simultaneous measurement of alphabeta activi-ties in the sample
bull Active shielding anti-coincidence background subtraction using GM counters
bull Lead shielding 30 mm
UMF-2000 LOW LEVEL ALPHA- BETA- COUNTER
Physical characteristicsDetectors bull Silicon specrometric detector 500 or 1000 mm2
Measurement range bull Alpha 001 divide 1000 Bq bull Beta 01 divide 3000 Bq
Energy range bull Alpha 35 divide 80 MeV bull Beta 005 divide 35 MeV
Electrical characteristicsPower supply bull 220 V 50 Hz
Interfaces bull RS-232bull USB
Mechanical characteristicsOverall dimensions weight bull 337times286times190 mm 22 kg
Versionsbull Detector area 500 mm2
bull Detector area 1000 mm2
UMF-2000 Detector area 1000 mm2
UMF-2000 Detector area 500 mm2
SpectraDec software for alpha-spectrometric measurements
SPC ldquoDozardquoRadiation monitoring equipment
64 65
DRK DOSE AREA PRODUCT METER
DRK-1bull Diagnostic reference level (DRL) of patients
determinationbull Suitable for all basic types of x-ray machines
Physical characteristicsDetector bull Plane-parallel ionization chamber
Measurement range bull 1 divide 104 cGycm2
Electrical characteristicsPower supply bull 220 V 50 Hz
DRK-1M-CTbull Measuring of dose length product
Physical characteristicsDetector bull Pencil Ionization Chamber
Measurement rangebull 05 divide 109 microGym
DRK-1Mbull Measuring of air kerma on sectional area of the
X-ray beam productbull Measuring of air kerma rate on area productbull Measuring of air kerma ratebull Measuring of air kerma
Physical characteristicsDetector bull Plane-parallel ionization chamber
Measurement rangebull 01 divide 109 microGym2
bull 06 divide 6104 microGym2cbull 30 divide 9105 microGycbull 30 divide 9991011 microGyReference standard IEC 60580 2003
bull Measurement of strontium-90 in the foodstuffs agricultural products etc
bull Measurement of gross beta activity in samplebull Self tests using built-in LED
ldquoPROGRESS-BETArdquo SCINTILLATION BETA SPECTROMETER
Physical characteristicsDetector bull Plastic scintillator Oslash70x10 mm
Sample bull Plate Oslash70 mmbull Weight up to 15 g
Energy range bull 02 divide 30 MeV
Minimum detectable activity of Sr-90 in a 10 g sample on a standard planchet Bqsamplebull In case of absence of K-40 in the sample 01 Bqbull In case the activity of K-40 till 5 Bqg 05 Bq
Electrical characteristics Interface bull USB
Mechanical characteristicsWeight bull No more 50 kg
Complete setBasic complete setbull Detector unit with plastic scintillator integrated
power supply amplifier ADC bull Lead shielding bull ldquoProgressrdquo software bull Сheck source for energetic calibration (Sr-90-Y-90) bull Planchet Oslash 70 mm (5 items) bull Sample dencification device bull Procedure manual for measurement of radio-
nuclidesrsquo activity using the scintillation beta spec-trometer ldquoProgressrdquo
Optional equipment and servicebull Personal computer and printer bull Calibrations for radionuclides not included in the
main library of radionuclides
Progress-Beta
Reference standards IEC 61562
SPC ldquoDozardquoRadiation monitoring equipment
66 67
bull Measurement of gamma activity in foodstuffs soil samples and others environmental objects
bull Identification of radionuclides in the sample bull Automatic correction for sample density bull Self-tests using built-in LED
ldquoPROGRESS-GAMMArdquoSCINTILLATION GAMMA SPECTROMETER
Physical characteristicsDetector bull NaI (Tl) Oslash63times63 mm
Validated measurement geometries bull Marinelli beakers (1 liter) Petri dishes (Oslash90 mm)
etc
Energy range bull 02 divide 30 MeV
Minimum detectable activity Bqsamplebull Cs-137 3 Bqbull Th-232 7 Bqbull Ra-226 8 Bq bull К-40 40 Bq
Electrical characteristics Interface bull USB
Mechanical characteristicsWeight bull No more 120 kg
Complete setBasic complete setbull Scintillation detector unit with NaI (Tl) detector
with integrated power supply amplifier and ADC bull Lead shielding 50 mm bull ldquoProgressrdquo software bull Сheck source for energy calibration (Cs-137 +
K-40)bull Marinelli beakers - 1 liter (5 items) bull Petri dishes Oslash 90 mm (5 items) bull Procedure manual for measurement of activity
of radionuclides using the scintillation gamma spectrometer ldquoProgressrdquo
Optional equipment and servicebull Kit for radon measurements including calibration
of ldquoIC-63rdquo geometry for counting the charcoal samples
bull Personal computer and printer bull Calibrations for user defined geometries bull Calibrations for radionuclides not included in the
main library of radionuclides
Progress-Gamma
Reference standards IEC 61563
ldquoPROGRESS-G(P)rdquoPORTABLE SCINTILLATION GAMMA SPECTROMETERbull Field measurements of gamma activity in environ-
mental objects without sampling (4π geometry)bull Laboratory measurement of gamma activity in
foodstuffs soil samples and others environmental objects
bull Identification of radionuclides in the sample bull Automatic correction for sample densitybull Tests using built-in LED
Physical charachteristicsDetector bull NaI (Tl) Oslash45times50 mmbull Lead shielding 20 mm
Validated measurement geometries bull Marinelli beakers (05 liter) Petri dishes (Oslash90 mm)
etc
Energy range bull 02 divide 30 MeV
Minimum detectable activity in 05-litre Marinelli beaker bull Cs-13710 Bqkgbull К-40100 Bqkgbull Ra-22618 Bqkg bull Th-23216 Bqkg
Minimum detectable activity in 30 min (4π geometry) bull Cs-137 2 Bqkgbull К-40 30 Bqkgbull Ra-226 4 Bqkg bull Th-232 3 Bqkg
Electrical characteristicsPower supply bull Rechargeable batterybull 220 V 50 Hz
Interface bull USB RS-232
Weight bull No more than 60 kg
Complete setBasic complete setbull Scinttillation detector unit with NaI(Tl) bull ldquoProgressrdquo softwarebull Сontrol unit ldquoSputnikrdquo for aquisition and analisys
of spectra with built-in memory for spectral databull Casebull Lead shielding (2 cm) for laboratory usebull 05-litre Marinelli beakers ndash 5 itemsbull Na-22 check sourcebull Power adapter BPS-01bull Operation manualbull Procedure manual for measurement of activity
of radionuclides using the scintillation gamma spectrometer ldquoProgressrdquo
Optional equipment and servicebull Kit for radon measurements with charcoalbull Built-in dose rate meterbull Additional memory (RAM) for storage of 64
spectrabull Additional power adapterbull Notebook and printer
Progress-Gamma
Reference standards IEC 61563
SPC ldquoDozardquoRadiation monitoring equipment
68 69
Physical characteristicsDetectorbull Scintillation detector ZnS (Oslash 60 mm)
Samplebull Thin sample - diameter up to 70 mm bull Preparation technique - electro-depositionbull Thick sample - diameter 70 mm weight
200300 mg bull Preparation technique - application of powders
(prepared by radiochemical concentration by water evaporation or by pounding of mineral samples) onto a planchet with the help of spirit
Energy rangebull 15 divide 8 MeV
Minimum detectable activitybull Thin samples no more than 910-3 Bqsamplebull Thick samples no more than 180 Bqkg
Mechanical characteristicsOverall dimensions weightbull 195times120times210 mm 34 kg
Complete setBasic complete setbull Alpha radiometer ldquoProgress-ARrdquobull Check source (uranium isotopes)
Set of accessoriesbull Procedure manual for measurements of radi-
oactivity using scintillation alpha radiometer ldquoProgress-ARrdquo
bull ldquoProgressrdquo software
ldquoProgress-ARrdquo
bull Measurement of gross activity of alpha emitting radionuclides in thin samples
bull Measurement of gross activity of alpha emitting radionuclides in thick samples
bull Measurement of activity deposited on aerosol filters
ldquoPROGRESS-ARrdquoALPHA RADIOMETER
Several fixed positions of the detector enable to perform measurements in various geometries and to estimate the content ofbull Cs-137 in the whole bodybull I-131 in thyroidbull Co-60 Cs-137 Mn-54 Cr-51 in lungsbull Database for storage of measurement data and
resultsbull Uncertainty calculations based on measurement
databull Self tests using built-in LED
ldquoPROGRESSrdquo WHOLE BODY COUNTER
Physical characteristicsDetectorbull scintillation detector NaI (Tl) Oslash63times63 mm
Energy rangebull 02 divide 28 MeV
Minimum detectable activitybull By Cs-137 in the whole body - 1200 Bqbull By I-131 in thyroid - 100 Bqbull By Co-60 Cs-137 Mn-54 Cr-51 in lungs - 200 Bq
Mechanical characteristicsWeight bull No more than 120 kg
Complete setBasic complete setbull Collimator with rotator and holderbull Detector with incorporated ADCbull Patient chair and table for collimatorbull Check source Na-22bull Procedure manual for lifetime measurement of
gamma-emitting radionuclidesrsquo activity in human body using the gamma-spectrometer of human radiation ldquoProgressrdquo
bull laquoProgressraquo software
Optional equipment and servicebull Program of internal radiation committed internal
radiation effective dose calculation by the stand-ard model
bull Background phantombull Personal computer and printer
Collimator with rotator and holder
SPC ldquoDozardquoRadiation monitoring equipment
70 71
bull Categorization of wastes for the purpose of fur-ther processing including wastes with unknown radionuclide composition
bull Measurements during the incoming waste inspec-tion (accepting for storage disposal)
bull Certification of unconditioned and conditioned wastes in closed containers without opening them (at nuclear plants or at facilities providing collection storage transportation conditioning processing temporal storage and final disposal of radioactive waste)
bull Activity measurement of extended objects in situ without opening the equipment
bull Activity measurement of extended objects after opening (for example assessment of tubes used for oil transportation)
MKG-01D ldquoSADOVNIKrdquoSPECTROMETRY SYSTEM
Physical charachteristicsDetectorbull Detector unit GEM (GMX) with HPGe detector and
multi-positioning cryostat CFG-PMOD4-7 with 7 litre Dewar
bull Dose rate probe BDMG-200
Energy range bull With GEM detector 004 divide 30 MeVbull With GMX detector 0005 divide 15 MeVbull Dose rate probe BDMG-200 ndash 005 divide 30 MeV
Measurement rangebull 110-7 divide 10 Svhbull Relative efficiency of detection (in photopeak) at
13325 MeV (Co-60) 10 divide 150
Electrical characteristicsPower supplybull 220 V 50 Hz
Interfacebull USB
Complete setBasic complete setbull Spectrometric detector unit GEM (GMX) with
HPGe detector and multi-positioning cryostat with 7 litre Dewar
bull Portable digital multichannel analyzer DigiDARTbull Dose rate probe BDMG-200bull Autonomous power supply unit with built-in
batterybull Industrial computer keyboardbull Laser range-finderbull Thermographic printerbull Web-camerabull Device equipped with stepper motor for position-
ing of the spectrometric detectorbull Calibration device with reference sources
(Am-241 Co-60 Ba-133 Eu-152) for energy calibration
bull Removable collimators with end capbull Measurement proceduresbull ldquoClasterrdquo software
bull Measurement of gross alpha activity of alpha-emitting radionuclides
bull Measurement of alpha-emitting radionuclides activity in thin-layer samples meeting alpha-spectrometry requirements
Physical characteristicsDetectorbull Silicon ion-implanted 450 mm2
bull Easy to decontaminate thin windowbull dead layer less than 015 μmbull Background count rate in the range 3 divide 9 MeVbull No more than 09 h-1cm-2 for 450 mm2 detector
Energy rangebull 2 divide 9 MeVbull Lower limit of measurement range (minimum
detectable activity) 01 Bqbull Background count rate no more than 100 counts
in 24 hours
Electrical characteristics Power supplybull 220 V 50 Hz
Interfacebull USB
Complete setBasic complete setbull Detector unit with vacuum measuring chamber
and vacuum control systembull Low noise vacuum pump (type 2FY-05B or
equivalent)bull Check sourcebull ldquoProgressrdquo softwarebull Vacuum tube
MKS-01A ldquoMULTIRAD-ASrdquoALPHA SPECTROMETER
SPC ldquoDozardquoRadiation monitoring equipment
72 73
UCRV-2AIRFLOW MONITOR
bull Monitor of the air flow through filter of centralized multichannel sampling system
bull Radiation monitoring system (RMS) integration for internal exposures determination
bull Volume and flow rate measurements of the air that have passed through a analytical filter
bull Bar-code for filter identificationbull Operation as either standalone unit or as a part of
the RMS
Physical characteristicsMeasurement range of air volume bull 001 divide 9999 m3
Operation temperature range bull minus 20 divide +50 ordmС
Electrical characteristicsPower supply bull 220 V 50 Hz
Interface bull RS-485
PVP-06PORTABLE AIR SAMPLER
Air Sampler PVP-06 is indispensable for monitoring the radiation situation where the concentration of radioactive aerosols in the air does not require a sta-tionary sampling equipment Sampling head PVP-06 provides easy change of filters and cartridges
Purposebull To monitor the concentration of radioactive aero-
sols in the air sites
Controlled aerosolsbull Alpha- and beta-active aerosolsbull Daughter products of decay of radon and thoronbull Iodine isotopes
Physical characteristicsTypes of filtersbull Aerosol AFA-RSP-20bull Iodine AFA SI-20
Flow rate bull 33∙10-4 ndash 233∙10-4 m3s (20 divide 140 l min)
Electrical characteristicsPower supply bull 220 V50 Hzbull The vehicle power supply 108 divide 145 Vbull Internal battery
Minimal working time on internal battery to recharge bull 8 hours
Power consumption (at a flow rate of 100 lmin) bull 40 VA
Environment characteristicsOperating temperature bull minus 10 divide +40 deg C
Maximum humidity bull 90
Pressure bull 860 to 1060 hPA
Noise generated by the pump bull lt 55 dBA at 1 m
Mechanical characteristicsDimensions weight bull 241 times 108 times 160 mm 28 kg
Case material bull Plastic
Complete setbull Air sampler PVP-06bull AC power adapterbull Filters AFA-RSP-20 - 100 pcsbull Packaging for filters - 40 pcsbull Casebull Operation manualbull Calibration certificate
Optional equimpient bull Kit for sampling sorption columns of activated
carbon Ř head of sorption columns with protective
covers Ř activated charcoal SKT-3 - 1 pkg (02 L) Ř charocoal samples SC-13 - 8 pcs
bull Car charger bull Tipod bull Shoulder strapbull Calibration stand bull Filters AFA SI-20 - 100 pcs
Consumablesbull Aerosol filters AFA RSP-20bull Iodine filters AFA SI-20
SPC ldquoDozardquoRadiation monitoring equipment
74 75
Calibration of gamma dose and dose rate meters
Calibration ofbull Ambient equivalent dose H(10) meters (Sv Svh)bull Personal equivalent dose Hp(10) meters (Sv Svh)bull Exposure dose X meters (R Rh)bull Two sources in irradiator bull Select source and collimator opening using
tumbler
UPG-P DESKTOP GAMMA BEAM IRRADIATOR
Physical characteristicsRange of reproduced dose rate bull 05 μSvh divide 10 mSvh (50 μRh divide 100 mRh)
Sources activities bull 6times106 6times108 Bq (02 20 mCi) Cs-137
Overall dimensions bull 1250times400times300 mm
Irradiator weight bull Not more than 37 kg
Calibration bench weight bull Not more than 15 kg
Reference standards IEC 60846 IEC 61526
Physical characteristicsDetectorbull Silicon
Measurement range EEC measurement bull Measurement range of radon EEC
10 divide 10bull106 Bqbullm-3
bull Measurement range of thoron EEC 05 divide 10bull104 Bqbullm-3
bull Air flow through the filter 100plusmn05 lmin
Concentration measurementbull Measurement range of radon-222 concentration
in air 10 divide 20bull106 cpsbull Measurement range of 216Po(ThA)
1bull10-3 divide 1bull102 cpsbull Air sampler flow rate
10plusmn02 lminbull Measurement range of radon-222 concentration
in water samples 6 divide 800 Bqbullkg-1
bull Measurement range of radon-222 flux from soil surface 20 divide 103 mBqsbullm2
bull Measurement range of radon-222 concentration with preliminary sampling of air using air sam-plers 20 divide 107 Bqbullm-3
bull Measurement range of radon-222 concentration in samples of soil air 103 divide 106 Bqbullm-3
Operation temperature range bull 1 divide 35 ordmC
Electrical characteristicsPower supply bull 80 VA
Mechanical characteristicsOverall dimensions weight bull 220times200times165 mm 36 kg
ldquoALPHARAD PLUSrdquoRADON THORON amp THEIR PROGENY MONITORbull Measurement of radon and thoron concentration
and effective equivalent concentration (EEC)bull In the airbull In the indoor air of residential public and industri-
al buildings and structuresbull Measurement of radon in drinking water sourcesbull Measurements of radon flux from the soil surface
at land plots allocated for construction of houses public buildings and industrial facilities
bull Measurements of radon concentration in soil air
Reference standards IEC 61577
SPC ldquoDozardquoRadiation monitoring equipment
76 77
UKPN-2M-D NEUTRON BEAM IRRADIATOR
Reference standards IEC 61005 61322
Calibration of neutron dose and dose rate meters
Calibration ofbull Ambient equivalent dose H(10) meters (Sv Svh)bull Personal equivalent dose Hp(10) meters (Sv Svh)bull Flux density of neutrons (cm-2∙s-1)bull Transfer container for temporary storage of
sources bull Red light signal of source working position
Physical carachteristicsRange of reproduced dose ratebull 20 divide 800 μSvh
Range of reproduced flux densitiesbull 10 divide 400 cm-2∙s-1
Type of a source in use bull Pu-Be
Activity of a source in usebull 24х1011 Bq (with density of 107 s-1)
Overall dimensions weight no morebull 3000x750x2000 mm 300 kg
Required room dimensionsbull not less than 7x3x3 m
Electrical characteristicsPower supply bull 220 V 50 Hz
Calibration of gamma dose and dose rate meters
Calibration ofbull Ambient equivalent dose H(10) meters (Sv Svh)bull Personal equivalent dose Hp(10) meters (Sv Svh)bull Exposure dose X meters (R Rh)bull Four sources in irradiator bull Select source and move to working position
return to storage position using special rodbull Transfer container for temporary storage of
sources bull Red light signal of source working position
UPGD-2M-DGAMMA BEAM IRRADIATOR
Physical characteristicsRange of reproduced dose rate bull 05 μSvh divide 50 mSvh (50 μRh divide 5 Rh)
Maximum activity of source bull 2times1011 Bq (50 Ci) Cs-137
Overall dimensionsbull Irradiator 800times500times500 mmbull Guide rails length 30 mbull Height 16 mbull Weight not more than 700 kgbull Required room dimensions not less than 7x3x3 m
Electrical characteristicsPower supply bull 220 V 50 Hz
UPGD-2M-D
Reference standards IEC 60846 IEC 61526 IEC 61066
SPC ldquoDozardquo
78 79
Contents
MEASURING UNITS
DBG-S11D wide range gamma area monitor 40
UDKS-100 gamma and X-ray area monitor 41
UDMN-100 neutron area monitor 41
ALARM UNITS
BAS-2 ldquoMICROrdquo external visual alarm 42
BZS-2 ldquoMicrordquo external audible alarm 42
Illuminated warning signs 43
ldquoImpulsrdquo external display unit 43
UIM-3D area monitor count rate meter 44
DKG-05D personal gamma dosimeter 46
DVS-02D gamma-neutron personal electronic dosimeter 47
DVGI-8D new pen-type personal ionization chamber dosimeters 48
DKG-02U ldquoARBITERrdquo wide range gamma-dosimeter 49
DKG-07D ldquoDROZDrdquo gamma-dosimeter 50
MKS-15D ldquoSNEGIRrdquo multi ndash purpose radiation survey meter 51
SRPS-05D gamma monitor 52
DOZA-TLD multipurpose TLD system 53
DKS-96 universal radiation survey meter 54
EXTERNAL PROBES ALPHA
Alpha BDZA-96 55
Alpha BDZA-96B 55
Alpha BDZA-96M 55
Alpha BDZA-96S 55
Alpha BDZA-96T 55
EXTERNAL PROBES BETA
Beta BDZB-96 56
Beta BDZB-99 56
Beta BDZB-96B 56
Beta BDZB-96S 56
EXTERNAL PROBES GAMMA
Gamma BDKS-96B 57
Gamma and beta BDKS-96S 57
Gamma BDMG-96 57
EXTERNAL PROBES GAMMA
Gamma-search BDVG-96 58
Gamma-search BDPG-96 58
ContentsRadiation monitoring systemldquoPELIKANrdquo Radiation monitoring system (RMS) 6
BDMG-101 high range gamma area monitor 10
DBG-S11D wide range gamma area monitor 11
BDRG-52 high range gamma area monitor for accident and post-accident conditions 12
UDGP-01 Liquid technological environments monitor 13
UDMN-100 neutron area monitor 14
UDKG-100 Wel Liquid gamma monitor 14
BOP-1M data processing and transmission unit 15
UDA-1AB particulate monitor 16
UDG-1B noble gas monitor 17
UDG-03D noble gas monitor 18
UDI-1B iodine monitor 19
UDGB-01 noble gasesH-3C-14 monitor 20
UDGP-01 steam generator leakage monitor 21
UPPVM air flow parameters monitor 22
ldquoIMPULSrdquo external display unit 23
BI-2 remote display amp alarm unit 24
BASBAS-1s external alarm 25
SKGAV stack monitor 26
RMS software 28
RMS workstation ndash operator console 29
Configurator software 29
RM RACK radiation monitoring rack 30
SRKS-01D criticality accident alarm system 32
ldquoATLANT-Mrdquo environmental radiation monitoring system 34
ldquoBREEZErdquo high-volume air sampler 35
ldquoGAMMA-SENSORrdquo gamma-survey system 36
Radiation monitoring equipmentAREA MONITOR ldquoFREGATrdquo 38
BPI-1D local display unit 39
80
Gamma-search BDPG-96M 58
Gamma BDKG-96 stainless steel casing for geologic applications well logging 59
EXTERNAL PROBES NEUTRON
Neutron BDMN-96 59
Neutron-search BDKN-96 59
RZB-05D Hand-foot-clothing monitor 60
RZBA-04-04M whole body contamination monitor 61
RZA-05D alpha hand-monitor 62
UMF-2000 low level alpha- beta- counter 63
DRK dose area product meter 64
ldquoPROGRESS-BETArdquo scintillation beta spectrometer 65
ldquoPROGRESS-GAMMArdquo scintillation gamma spectrometer 66
ldquoPROGRESS-G(P)rdquo portable scintillation gamma spectrometer 67
ldquoPROGRESS-ARrdquo alpha radiometer 68
ldquoPROGRESSrdquo whole body counter 69
MKG-01D ldquoSADOVNIKrdquo spectrometry system 70
MKS-01A ldquoMULTIRAD-ASrdquo alpha spectrometer 71
UCRV-2 airflow monitor 72
PVP-06 portable air sampler 73
ldquoALPHARAD PLUSrdquo radon thoron amp their progeny monitor 74
UPG-P desktop gamma beam irradiator 75
UPGD-2M-D gamma beam irradiator 76
UKPN-2M-D neutron beam irradiator 77
SPC ldquoDozardquoRadiation monitoring equipment
58 59
GAMMA-SEARCH BDVG-96Detector bull Scintillator NaI(Tl) Oslash 63times63 mm
Measurement rangebull Flux density measurement range 4 divide 2000 s-1cm-2
bull Dose rate H(10) for Cs-137 01 divide 30 μSvhbull Sensitivity for Cs-137 3000 (pulsess-1)( μSvh-1)
Overall dimensions weightbull Oslash 88times400 mm 20 kgbull Modular pole length 16 m
GAMMA-SEARCH BDPG-96Detector bull Scintillator NaI(Tl) Oslash 25times40 mm
Measurement rangebull Flux density measurement range 10 divide 8000 s-1cm-2
bull Dose rate H(10) for Cs-137 01 divide 100 μSvhbull Sensitivity for Cs-137 500 (pulsess-1)( μSvh-1)
Overall dimensions weightbull 50times190times480 mm 10 kgbull Telescopic pole length 07 m
GAMMA-SEARCH BDPG-96MDetector bull Scintillator NaI(Tl) Oslash 18times30 mm
Measurement rangebull Flux density measurement range 10 divide 24000 s-1cm-2
bull Dose rate H(10) for Cs-137 01 divide 300 μSvhbull Sensitivity for Cs-137 200 (pulsess-1)( μSvh-1)
Overall dimensions weightbull Oslash 35times320 mm 05 kgbull Telescopic pole length 07 or 38 m
EXTERNAL PROBES GAMMA
BDVG-96
BDPG-96M
BDPG-96
EXTERNAL PROBESGAMMA BDKG-96 STAINLESS STEEL CASING FOR GEOLOGIC APPLICATIONS WELL LOGGINGDetector bull Scintillator NaI(Tl) Oslash 18times30 mm
Measurement rangebull Flux density measurement range 10 divide 105 s-1cm-2
bull Dose rate H(10) for Cs-137 5 divide 2104 μRhbull Sensitivity for Cs-137 200 (pulsess-1)( μSvh-1)
Overall dimensions weightbull Oslash 38times535 mm 36 kgbull Cable length 10 divide 1000 m
NEUTRON BDMN-96Detector bull Scintillator with ZnS(Ag)
Measurement rangebull Dose rate H(10) 01 μSvh divide 01 Svhbull Dose H(10) 01 μSv divide 10 Sv
Energy range bull 0025 eV divide 10 MeV
Overall dimensions weightbull Detector Oslash 54times200 mm 08 kgbull Moderator Oslash 245 mm 73 kg
NEUTRON-SEARCH BDKN-96Detector bull He-3 counter in polyethilene moderator
Measurement rangebull Dose rate H(10) for Pu-Be 01 μSvh divide 01 Svhbull Dose H(10) for Pu-Be 01 μSv divide 10 Sv
Energy range bull 0025 eV divide 14 MeV
Overall dimensions weightbull 295times142times100 mm 225 kg
BDKG-96M
BDMN-96
BDKN-96
SPC ldquoDozardquoRadiation monitoring equipment
60 61
bull No gas supply neededbull Clothing control detachable right hand detector bull Alpha detector optional connection bull Numeric and color (red green) indication of
control resultsbull LED sensor of hand-foot positioning for start of
measurementbull Automatic compensation of gamma background
and contamination of detectorbull Audible alarm signals of the excess of preset
thresholdsbull Measurement value indication min-1cm-2 or
Bqсm2
Reference standards Nuclear IEC 61098
RZB-05D HAND-FOOT-CLOTHING MONITOR
Physical characteristicsDetectors bull Gamma beta - GM countersbull Alpha - scintillatior ZnS(Ag)
Detecting nuclidesbull Alpha Pu-239 U-234 U-238bull Beta Sr-90+Y-90 F-18 Cs-137 Co-60 Tс-99 O-15
N-13 Sr-89 C-11 I-131 Na-22 Ru-106+Rh-106 Tl-204
bull Gamma Tc-99m I-123
Efficiencybull Alpha
Pu-239 40 U-234 25U-238 15
bull Beta Sr-90 +Y-90 40
Measurement range bull Alpha 1 divide 103 min-1cm-2 bull Beta 10 divide 103 min-1cm-2
bull Gamma 5103 divide 5106 min-1cm-2
Energy range bull Alpha 30 divide 80 MeV bull Beta 008 divide 35 MeV bull Gamma 005 divide 30 MeV
Operation temperature range bull Minus 10 divide +50 ordmС
Electrical characteristicsbull Power supply 220 V 50 Hz
Mechanical characteristicsOverall dimensions weight bull 740times750times1180 mm 45 kg
Versionsbull Withwithout alpha detectorbull Indication (min-1cm-2 ) or (Bqсm2)bull Detectors overall dimensions smbull Hand 178 х 235bull Foot 185 х 436
Whole body contamination monitor RZBA-04-04Mbull No gas supply neededbull Compensation for background gamma radiation
and contamination of detector unitsbull Individual threshold setting for each measure-
ment channelbull Visible and audible alarms ldquoCONTAMINATIONrdquo and
ldquoCLEANrdquo bull Indication of contaminated body parts on the
panel with image of the bodybull Optional remote alpha-detector
Physical characteristicsDetectors bull Beta - GM counters scintillatorsbull Alpha - scintillatior ZnS(Ag)
Measurement range bull Beta 5 divide 15000 min-1cm-2
bull Alpha 01 divide 10000 min-1cm-2
Energy range bull Beta 015 divide 25 MeV bull Alpha 40 divide 56 MeV
Operation temperature range bull +5 divide +50 ordmС
Electrical characteristicsPower supply bull 220 V 50 Hz
Interfaces bull RS-232bull RS-485
Mechanical characteristicsOverall dimensions weight bull 2650times940times930 mm 310 kg
Versionsbull Withwithout alpha detectorbull Indication (min-1cm-2 ) or (Bqсm2)
Reference standards Nuclear IEC 61098
RZBA-04-04MWHOLE BODY CONTAMINATION MONITOR
SPC ldquoDozardquoRadiation monitoring equipment
62 63
RZA-05DALPHA HAND-MONITOR
bull No gas supply needed bull Numeric and color (red green) indication of
control resultsbull LED sensor of hand- positioning for start of
measurementbull Audible alarm signals of the excess of preset
thresholdsbull Measurement value indication min-1cm-2 or
Bqсm2
Physical characteristicsDetectors alpha - scintillatior ZnS(Ag)
Efficiencybull Pu-239 20 bull U-234 14bull U-238 8
Measurement range bull 05 divide 105 min-1cm-2
Energy range bull 41 divide 90 MeV
Operation temperature range bull minus 10 divide +50 ordmС
Electrical characteristicsPower supply bull 220 V 50 Hz
Mechanical characteristicsOverall dimensions weight no more bull 740times1400times1450 mm 70 kg
Reference standards Nuclear IEC 61098
bull Simultaneous measurement of alphabeta activi-ties in the sample
bull Active shielding anti-coincidence background subtraction using GM counters
bull Lead shielding 30 mm
UMF-2000 LOW LEVEL ALPHA- BETA- COUNTER
Physical characteristicsDetectors bull Silicon specrometric detector 500 or 1000 mm2
Measurement range bull Alpha 001 divide 1000 Bq bull Beta 01 divide 3000 Bq
Energy range bull Alpha 35 divide 80 MeV bull Beta 005 divide 35 MeV
Electrical characteristicsPower supply bull 220 V 50 Hz
Interfaces bull RS-232bull USB
Mechanical characteristicsOverall dimensions weight bull 337times286times190 mm 22 kg
Versionsbull Detector area 500 mm2
bull Detector area 1000 mm2
UMF-2000 Detector area 1000 mm2
UMF-2000 Detector area 500 mm2
SpectraDec software for alpha-spectrometric measurements
SPC ldquoDozardquoRadiation monitoring equipment
64 65
DRK DOSE AREA PRODUCT METER
DRK-1bull Diagnostic reference level (DRL) of patients
determinationbull Suitable for all basic types of x-ray machines
Physical characteristicsDetector bull Plane-parallel ionization chamber
Measurement range bull 1 divide 104 cGycm2
Electrical characteristicsPower supply bull 220 V 50 Hz
DRK-1M-CTbull Measuring of dose length product
Physical characteristicsDetector bull Pencil Ionization Chamber
Measurement rangebull 05 divide 109 microGym
DRK-1Mbull Measuring of air kerma on sectional area of the
X-ray beam productbull Measuring of air kerma rate on area productbull Measuring of air kerma ratebull Measuring of air kerma
Physical characteristicsDetector bull Plane-parallel ionization chamber
Measurement rangebull 01 divide 109 microGym2
bull 06 divide 6104 microGym2cbull 30 divide 9105 microGycbull 30 divide 9991011 microGyReference standard IEC 60580 2003
bull Measurement of strontium-90 in the foodstuffs agricultural products etc
bull Measurement of gross beta activity in samplebull Self tests using built-in LED
ldquoPROGRESS-BETArdquo SCINTILLATION BETA SPECTROMETER
Physical characteristicsDetector bull Plastic scintillator Oslash70x10 mm
Sample bull Plate Oslash70 mmbull Weight up to 15 g
Energy range bull 02 divide 30 MeV
Minimum detectable activity of Sr-90 in a 10 g sample on a standard planchet Bqsamplebull In case of absence of K-40 in the sample 01 Bqbull In case the activity of K-40 till 5 Bqg 05 Bq
Electrical characteristics Interface bull USB
Mechanical characteristicsWeight bull No more 50 kg
Complete setBasic complete setbull Detector unit with plastic scintillator integrated
power supply amplifier ADC bull Lead shielding bull ldquoProgressrdquo software bull Сheck source for energetic calibration (Sr-90-Y-90) bull Planchet Oslash 70 mm (5 items) bull Sample dencification device bull Procedure manual for measurement of radio-
nuclidesrsquo activity using the scintillation beta spec-trometer ldquoProgressrdquo
Optional equipment and servicebull Personal computer and printer bull Calibrations for radionuclides not included in the
main library of radionuclides
Progress-Beta
Reference standards IEC 61562
SPC ldquoDozardquoRadiation monitoring equipment
66 67
bull Measurement of gamma activity in foodstuffs soil samples and others environmental objects
bull Identification of radionuclides in the sample bull Automatic correction for sample density bull Self-tests using built-in LED
ldquoPROGRESS-GAMMArdquoSCINTILLATION GAMMA SPECTROMETER
Physical characteristicsDetector bull NaI (Tl) Oslash63times63 mm
Validated measurement geometries bull Marinelli beakers (1 liter) Petri dishes (Oslash90 mm)
etc
Energy range bull 02 divide 30 MeV
Minimum detectable activity Bqsamplebull Cs-137 3 Bqbull Th-232 7 Bqbull Ra-226 8 Bq bull К-40 40 Bq
Electrical characteristics Interface bull USB
Mechanical characteristicsWeight bull No more 120 kg
Complete setBasic complete setbull Scintillation detector unit with NaI (Tl) detector
with integrated power supply amplifier and ADC bull Lead shielding 50 mm bull ldquoProgressrdquo software bull Сheck source for energy calibration (Cs-137 +
K-40)bull Marinelli beakers - 1 liter (5 items) bull Petri dishes Oslash 90 mm (5 items) bull Procedure manual for measurement of activity
of radionuclides using the scintillation gamma spectrometer ldquoProgressrdquo
Optional equipment and servicebull Kit for radon measurements including calibration
of ldquoIC-63rdquo geometry for counting the charcoal samples
bull Personal computer and printer bull Calibrations for user defined geometries bull Calibrations for radionuclides not included in the
main library of radionuclides
Progress-Gamma
Reference standards IEC 61563
ldquoPROGRESS-G(P)rdquoPORTABLE SCINTILLATION GAMMA SPECTROMETERbull Field measurements of gamma activity in environ-
mental objects without sampling (4π geometry)bull Laboratory measurement of gamma activity in
foodstuffs soil samples and others environmental objects
bull Identification of radionuclides in the sample bull Automatic correction for sample densitybull Tests using built-in LED
Physical charachteristicsDetector bull NaI (Tl) Oslash45times50 mmbull Lead shielding 20 mm
Validated measurement geometries bull Marinelli beakers (05 liter) Petri dishes (Oslash90 mm)
etc
Energy range bull 02 divide 30 MeV
Minimum detectable activity in 05-litre Marinelli beaker bull Cs-13710 Bqkgbull К-40100 Bqkgbull Ra-22618 Bqkg bull Th-23216 Bqkg
Minimum detectable activity in 30 min (4π geometry) bull Cs-137 2 Bqkgbull К-40 30 Bqkgbull Ra-226 4 Bqkg bull Th-232 3 Bqkg
Electrical characteristicsPower supply bull Rechargeable batterybull 220 V 50 Hz
Interface bull USB RS-232
Weight bull No more than 60 kg
Complete setBasic complete setbull Scinttillation detector unit with NaI(Tl) bull ldquoProgressrdquo softwarebull Сontrol unit ldquoSputnikrdquo for aquisition and analisys
of spectra with built-in memory for spectral databull Casebull Lead shielding (2 cm) for laboratory usebull 05-litre Marinelli beakers ndash 5 itemsbull Na-22 check sourcebull Power adapter BPS-01bull Operation manualbull Procedure manual for measurement of activity
of radionuclides using the scintillation gamma spectrometer ldquoProgressrdquo
Optional equipment and servicebull Kit for radon measurements with charcoalbull Built-in dose rate meterbull Additional memory (RAM) for storage of 64
spectrabull Additional power adapterbull Notebook and printer
Progress-Gamma
Reference standards IEC 61563
SPC ldquoDozardquoRadiation monitoring equipment
68 69
Physical characteristicsDetectorbull Scintillation detector ZnS (Oslash 60 mm)
Samplebull Thin sample - diameter up to 70 mm bull Preparation technique - electro-depositionbull Thick sample - diameter 70 mm weight
200300 mg bull Preparation technique - application of powders
(prepared by radiochemical concentration by water evaporation or by pounding of mineral samples) onto a planchet with the help of spirit
Energy rangebull 15 divide 8 MeV
Minimum detectable activitybull Thin samples no more than 910-3 Bqsamplebull Thick samples no more than 180 Bqkg
Mechanical characteristicsOverall dimensions weightbull 195times120times210 mm 34 kg
Complete setBasic complete setbull Alpha radiometer ldquoProgress-ARrdquobull Check source (uranium isotopes)
Set of accessoriesbull Procedure manual for measurements of radi-
oactivity using scintillation alpha radiometer ldquoProgress-ARrdquo
bull ldquoProgressrdquo software
ldquoProgress-ARrdquo
bull Measurement of gross activity of alpha emitting radionuclides in thin samples
bull Measurement of gross activity of alpha emitting radionuclides in thick samples
bull Measurement of activity deposited on aerosol filters
ldquoPROGRESS-ARrdquoALPHA RADIOMETER
Several fixed positions of the detector enable to perform measurements in various geometries and to estimate the content ofbull Cs-137 in the whole bodybull I-131 in thyroidbull Co-60 Cs-137 Mn-54 Cr-51 in lungsbull Database for storage of measurement data and
resultsbull Uncertainty calculations based on measurement
databull Self tests using built-in LED
ldquoPROGRESSrdquo WHOLE BODY COUNTER
Physical characteristicsDetectorbull scintillation detector NaI (Tl) Oslash63times63 mm
Energy rangebull 02 divide 28 MeV
Minimum detectable activitybull By Cs-137 in the whole body - 1200 Bqbull By I-131 in thyroid - 100 Bqbull By Co-60 Cs-137 Mn-54 Cr-51 in lungs - 200 Bq
Mechanical characteristicsWeight bull No more than 120 kg
Complete setBasic complete setbull Collimator with rotator and holderbull Detector with incorporated ADCbull Patient chair and table for collimatorbull Check source Na-22bull Procedure manual for lifetime measurement of
gamma-emitting radionuclidesrsquo activity in human body using the gamma-spectrometer of human radiation ldquoProgressrdquo
bull laquoProgressraquo software
Optional equipment and servicebull Program of internal radiation committed internal
radiation effective dose calculation by the stand-ard model
bull Background phantombull Personal computer and printer
Collimator with rotator and holder
SPC ldquoDozardquoRadiation monitoring equipment
70 71
bull Categorization of wastes for the purpose of fur-ther processing including wastes with unknown radionuclide composition
bull Measurements during the incoming waste inspec-tion (accepting for storage disposal)
bull Certification of unconditioned and conditioned wastes in closed containers without opening them (at nuclear plants or at facilities providing collection storage transportation conditioning processing temporal storage and final disposal of radioactive waste)
bull Activity measurement of extended objects in situ without opening the equipment
bull Activity measurement of extended objects after opening (for example assessment of tubes used for oil transportation)
MKG-01D ldquoSADOVNIKrdquoSPECTROMETRY SYSTEM
Physical charachteristicsDetectorbull Detector unit GEM (GMX) with HPGe detector and
multi-positioning cryostat CFG-PMOD4-7 with 7 litre Dewar
bull Dose rate probe BDMG-200
Energy range bull With GEM detector 004 divide 30 MeVbull With GMX detector 0005 divide 15 MeVbull Dose rate probe BDMG-200 ndash 005 divide 30 MeV
Measurement rangebull 110-7 divide 10 Svhbull Relative efficiency of detection (in photopeak) at
13325 MeV (Co-60) 10 divide 150
Electrical characteristicsPower supplybull 220 V 50 Hz
Interfacebull USB
Complete setBasic complete setbull Spectrometric detector unit GEM (GMX) with
HPGe detector and multi-positioning cryostat with 7 litre Dewar
bull Portable digital multichannel analyzer DigiDARTbull Dose rate probe BDMG-200bull Autonomous power supply unit with built-in
batterybull Industrial computer keyboardbull Laser range-finderbull Thermographic printerbull Web-camerabull Device equipped with stepper motor for position-
ing of the spectrometric detectorbull Calibration device with reference sources
(Am-241 Co-60 Ba-133 Eu-152) for energy calibration
bull Removable collimators with end capbull Measurement proceduresbull ldquoClasterrdquo software
bull Measurement of gross alpha activity of alpha-emitting radionuclides
bull Measurement of alpha-emitting radionuclides activity in thin-layer samples meeting alpha-spectrometry requirements
Physical characteristicsDetectorbull Silicon ion-implanted 450 mm2
bull Easy to decontaminate thin windowbull dead layer less than 015 μmbull Background count rate in the range 3 divide 9 MeVbull No more than 09 h-1cm-2 for 450 mm2 detector
Energy rangebull 2 divide 9 MeVbull Lower limit of measurement range (minimum
detectable activity) 01 Bqbull Background count rate no more than 100 counts
in 24 hours
Electrical characteristics Power supplybull 220 V 50 Hz
Interfacebull USB
Complete setBasic complete setbull Detector unit with vacuum measuring chamber
and vacuum control systembull Low noise vacuum pump (type 2FY-05B or
equivalent)bull Check sourcebull ldquoProgressrdquo softwarebull Vacuum tube
MKS-01A ldquoMULTIRAD-ASrdquoALPHA SPECTROMETER
SPC ldquoDozardquoRadiation monitoring equipment
72 73
UCRV-2AIRFLOW MONITOR
bull Monitor of the air flow through filter of centralized multichannel sampling system
bull Radiation monitoring system (RMS) integration for internal exposures determination
bull Volume and flow rate measurements of the air that have passed through a analytical filter
bull Bar-code for filter identificationbull Operation as either standalone unit or as a part of
the RMS
Physical characteristicsMeasurement range of air volume bull 001 divide 9999 m3
Operation temperature range bull minus 20 divide +50 ordmС
Electrical characteristicsPower supply bull 220 V 50 Hz
Interface bull RS-485
PVP-06PORTABLE AIR SAMPLER
Air Sampler PVP-06 is indispensable for monitoring the radiation situation where the concentration of radioactive aerosols in the air does not require a sta-tionary sampling equipment Sampling head PVP-06 provides easy change of filters and cartridges
Purposebull To monitor the concentration of radioactive aero-
sols in the air sites
Controlled aerosolsbull Alpha- and beta-active aerosolsbull Daughter products of decay of radon and thoronbull Iodine isotopes
Physical characteristicsTypes of filtersbull Aerosol AFA-RSP-20bull Iodine AFA SI-20
Flow rate bull 33∙10-4 ndash 233∙10-4 m3s (20 divide 140 l min)
Electrical characteristicsPower supply bull 220 V50 Hzbull The vehicle power supply 108 divide 145 Vbull Internal battery
Minimal working time on internal battery to recharge bull 8 hours
Power consumption (at a flow rate of 100 lmin) bull 40 VA
Environment characteristicsOperating temperature bull minus 10 divide +40 deg C
Maximum humidity bull 90
Pressure bull 860 to 1060 hPA
Noise generated by the pump bull lt 55 dBA at 1 m
Mechanical characteristicsDimensions weight bull 241 times 108 times 160 mm 28 kg
Case material bull Plastic
Complete setbull Air sampler PVP-06bull AC power adapterbull Filters AFA-RSP-20 - 100 pcsbull Packaging for filters - 40 pcsbull Casebull Operation manualbull Calibration certificate
Optional equimpient bull Kit for sampling sorption columns of activated
carbon Ř head of sorption columns with protective
covers Ř activated charcoal SKT-3 - 1 pkg (02 L) Ř charocoal samples SC-13 - 8 pcs
bull Car charger bull Tipod bull Shoulder strapbull Calibration stand bull Filters AFA SI-20 - 100 pcs
Consumablesbull Aerosol filters AFA RSP-20bull Iodine filters AFA SI-20
SPC ldquoDozardquoRadiation monitoring equipment
74 75
Calibration of gamma dose and dose rate meters
Calibration ofbull Ambient equivalent dose H(10) meters (Sv Svh)bull Personal equivalent dose Hp(10) meters (Sv Svh)bull Exposure dose X meters (R Rh)bull Two sources in irradiator bull Select source and collimator opening using
tumbler
UPG-P DESKTOP GAMMA BEAM IRRADIATOR
Physical characteristicsRange of reproduced dose rate bull 05 μSvh divide 10 mSvh (50 μRh divide 100 mRh)
Sources activities bull 6times106 6times108 Bq (02 20 mCi) Cs-137
Overall dimensions bull 1250times400times300 mm
Irradiator weight bull Not more than 37 kg
Calibration bench weight bull Not more than 15 kg
Reference standards IEC 60846 IEC 61526
Physical characteristicsDetectorbull Silicon
Measurement range EEC measurement bull Measurement range of radon EEC
10 divide 10bull106 Bqbullm-3
bull Measurement range of thoron EEC 05 divide 10bull104 Bqbullm-3
bull Air flow through the filter 100plusmn05 lmin
Concentration measurementbull Measurement range of radon-222 concentration
in air 10 divide 20bull106 cpsbull Measurement range of 216Po(ThA)
1bull10-3 divide 1bull102 cpsbull Air sampler flow rate
10plusmn02 lminbull Measurement range of radon-222 concentration
in water samples 6 divide 800 Bqbullkg-1
bull Measurement range of radon-222 flux from soil surface 20 divide 103 mBqsbullm2
bull Measurement range of radon-222 concentration with preliminary sampling of air using air sam-plers 20 divide 107 Bqbullm-3
bull Measurement range of radon-222 concentration in samples of soil air 103 divide 106 Bqbullm-3
Operation temperature range bull 1 divide 35 ordmC
Electrical characteristicsPower supply bull 80 VA
Mechanical characteristicsOverall dimensions weight bull 220times200times165 mm 36 kg
ldquoALPHARAD PLUSrdquoRADON THORON amp THEIR PROGENY MONITORbull Measurement of radon and thoron concentration
and effective equivalent concentration (EEC)bull In the airbull In the indoor air of residential public and industri-
al buildings and structuresbull Measurement of radon in drinking water sourcesbull Measurements of radon flux from the soil surface
at land plots allocated for construction of houses public buildings and industrial facilities
bull Measurements of radon concentration in soil air
Reference standards IEC 61577
SPC ldquoDozardquoRadiation monitoring equipment
76 77
UKPN-2M-D NEUTRON BEAM IRRADIATOR
Reference standards IEC 61005 61322
Calibration of neutron dose and dose rate meters
Calibration ofbull Ambient equivalent dose H(10) meters (Sv Svh)bull Personal equivalent dose Hp(10) meters (Sv Svh)bull Flux density of neutrons (cm-2∙s-1)bull Transfer container for temporary storage of
sources bull Red light signal of source working position
Physical carachteristicsRange of reproduced dose ratebull 20 divide 800 μSvh
Range of reproduced flux densitiesbull 10 divide 400 cm-2∙s-1
Type of a source in use bull Pu-Be
Activity of a source in usebull 24х1011 Bq (with density of 107 s-1)
Overall dimensions weight no morebull 3000x750x2000 mm 300 kg
Required room dimensionsbull not less than 7x3x3 m
Electrical characteristicsPower supply bull 220 V 50 Hz
Calibration of gamma dose and dose rate meters
Calibration ofbull Ambient equivalent dose H(10) meters (Sv Svh)bull Personal equivalent dose Hp(10) meters (Sv Svh)bull Exposure dose X meters (R Rh)bull Four sources in irradiator bull Select source and move to working position
return to storage position using special rodbull Transfer container for temporary storage of
sources bull Red light signal of source working position
UPGD-2M-DGAMMA BEAM IRRADIATOR
Physical characteristicsRange of reproduced dose rate bull 05 μSvh divide 50 mSvh (50 μRh divide 5 Rh)
Maximum activity of source bull 2times1011 Bq (50 Ci) Cs-137
Overall dimensionsbull Irradiator 800times500times500 mmbull Guide rails length 30 mbull Height 16 mbull Weight not more than 700 kgbull Required room dimensions not less than 7x3x3 m
Electrical characteristicsPower supply bull 220 V 50 Hz
UPGD-2M-D
Reference standards IEC 60846 IEC 61526 IEC 61066
SPC ldquoDozardquo
78 79
Contents
MEASURING UNITS
DBG-S11D wide range gamma area monitor 40
UDKS-100 gamma and X-ray area monitor 41
UDMN-100 neutron area monitor 41
ALARM UNITS
BAS-2 ldquoMICROrdquo external visual alarm 42
BZS-2 ldquoMicrordquo external audible alarm 42
Illuminated warning signs 43
ldquoImpulsrdquo external display unit 43
UIM-3D area monitor count rate meter 44
DKG-05D personal gamma dosimeter 46
DVS-02D gamma-neutron personal electronic dosimeter 47
DVGI-8D new pen-type personal ionization chamber dosimeters 48
DKG-02U ldquoARBITERrdquo wide range gamma-dosimeter 49
DKG-07D ldquoDROZDrdquo gamma-dosimeter 50
MKS-15D ldquoSNEGIRrdquo multi ndash purpose radiation survey meter 51
SRPS-05D gamma monitor 52
DOZA-TLD multipurpose TLD system 53
DKS-96 universal radiation survey meter 54
EXTERNAL PROBES ALPHA
Alpha BDZA-96 55
Alpha BDZA-96B 55
Alpha BDZA-96M 55
Alpha BDZA-96S 55
Alpha BDZA-96T 55
EXTERNAL PROBES BETA
Beta BDZB-96 56
Beta BDZB-99 56
Beta BDZB-96B 56
Beta BDZB-96S 56
EXTERNAL PROBES GAMMA
Gamma BDKS-96B 57
Gamma and beta BDKS-96S 57
Gamma BDMG-96 57
EXTERNAL PROBES GAMMA
Gamma-search BDVG-96 58
Gamma-search BDPG-96 58
ContentsRadiation monitoring systemldquoPELIKANrdquo Radiation monitoring system (RMS) 6
BDMG-101 high range gamma area monitor 10
DBG-S11D wide range gamma area monitor 11
BDRG-52 high range gamma area monitor for accident and post-accident conditions 12
UDGP-01 Liquid technological environments monitor 13
UDMN-100 neutron area monitor 14
UDKG-100 Wel Liquid gamma monitor 14
BOP-1M data processing and transmission unit 15
UDA-1AB particulate monitor 16
UDG-1B noble gas monitor 17
UDG-03D noble gas monitor 18
UDI-1B iodine monitor 19
UDGB-01 noble gasesH-3C-14 monitor 20
UDGP-01 steam generator leakage monitor 21
UPPVM air flow parameters monitor 22
ldquoIMPULSrdquo external display unit 23
BI-2 remote display amp alarm unit 24
BASBAS-1s external alarm 25
SKGAV stack monitor 26
RMS software 28
RMS workstation ndash operator console 29
Configurator software 29
RM RACK radiation monitoring rack 30
SRKS-01D criticality accident alarm system 32
ldquoATLANT-Mrdquo environmental radiation monitoring system 34
ldquoBREEZErdquo high-volume air sampler 35
ldquoGAMMA-SENSORrdquo gamma-survey system 36
Radiation monitoring equipmentAREA MONITOR ldquoFREGATrdquo 38
BPI-1D local display unit 39
80
Gamma-search BDPG-96M 58
Gamma BDKG-96 stainless steel casing for geologic applications well logging 59
EXTERNAL PROBES NEUTRON
Neutron BDMN-96 59
Neutron-search BDKN-96 59
RZB-05D Hand-foot-clothing monitor 60
RZBA-04-04M whole body contamination monitor 61
RZA-05D alpha hand-monitor 62
UMF-2000 low level alpha- beta- counter 63
DRK dose area product meter 64
ldquoPROGRESS-BETArdquo scintillation beta spectrometer 65
ldquoPROGRESS-GAMMArdquo scintillation gamma spectrometer 66
ldquoPROGRESS-G(P)rdquo portable scintillation gamma spectrometer 67
ldquoPROGRESS-ARrdquo alpha radiometer 68
ldquoPROGRESSrdquo whole body counter 69
MKG-01D ldquoSADOVNIKrdquo spectrometry system 70
MKS-01A ldquoMULTIRAD-ASrdquo alpha spectrometer 71
UCRV-2 airflow monitor 72
PVP-06 portable air sampler 73
ldquoALPHARAD PLUSrdquo radon thoron amp their progeny monitor 74
UPG-P desktop gamma beam irradiator 75
UPGD-2M-D gamma beam irradiator 76
UKPN-2M-D neutron beam irradiator 77
SPC ldquoDozardquoRadiation monitoring equipment
60 61
bull No gas supply neededbull Clothing control detachable right hand detector bull Alpha detector optional connection bull Numeric and color (red green) indication of
control resultsbull LED sensor of hand-foot positioning for start of
measurementbull Automatic compensation of gamma background
and contamination of detectorbull Audible alarm signals of the excess of preset
thresholdsbull Measurement value indication min-1cm-2 or
Bqсm2
Reference standards Nuclear IEC 61098
RZB-05D HAND-FOOT-CLOTHING MONITOR
Physical characteristicsDetectors bull Gamma beta - GM countersbull Alpha - scintillatior ZnS(Ag)
Detecting nuclidesbull Alpha Pu-239 U-234 U-238bull Beta Sr-90+Y-90 F-18 Cs-137 Co-60 Tс-99 O-15
N-13 Sr-89 C-11 I-131 Na-22 Ru-106+Rh-106 Tl-204
bull Gamma Tc-99m I-123
Efficiencybull Alpha
Pu-239 40 U-234 25U-238 15
bull Beta Sr-90 +Y-90 40
Measurement range bull Alpha 1 divide 103 min-1cm-2 bull Beta 10 divide 103 min-1cm-2
bull Gamma 5103 divide 5106 min-1cm-2
Energy range bull Alpha 30 divide 80 MeV bull Beta 008 divide 35 MeV bull Gamma 005 divide 30 MeV
Operation temperature range bull Minus 10 divide +50 ordmС
Electrical characteristicsbull Power supply 220 V 50 Hz
Mechanical characteristicsOverall dimensions weight bull 740times750times1180 mm 45 kg
Versionsbull Withwithout alpha detectorbull Indication (min-1cm-2 ) or (Bqсm2)bull Detectors overall dimensions smbull Hand 178 х 235bull Foot 185 х 436
Whole body contamination monitor RZBA-04-04Mbull No gas supply neededbull Compensation for background gamma radiation
and contamination of detector unitsbull Individual threshold setting for each measure-
ment channelbull Visible and audible alarms ldquoCONTAMINATIONrdquo and
ldquoCLEANrdquo bull Indication of contaminated body parts on the
panel with image of the bodybull Optional remote alpha-detector
Physical characteristicsDetectors bull Beta - GM counters scintillatorsbull Alpha - scintillatior ZnS(Ag)
Measurement range bull Beta 5 divide 15000 min-1cm-2
bull Alpha 01 divide 10000 min-1cm-2
Energy range bull Beta 015 divide 25 MeV bull Alpha 40 divide 56 MeV
Operation temperature range bull +5 divide +50 ordmС
Electrical characteristicsPower supply bull 220 V 50 Hz
Interfaces bull RS-232bull RS-485
Mechanical characteristicsOverall dimensions weight bull 2650times940times930 mm 310 kg
Versionsbull Withwithout alpha detectorbull Indication (min-1cm-2 ) or (Bqсm2)
Reference standards Nuclear IEC 61098
RZBA-04-04MWHOLE BODY CONTAMINATION MONITOR
SPC ldquoDozardquoRadiation monitoring equipment
62 63
RZA-05DALPHA HAND-MONITOR
bull No gas supply needed bull Numeric and color (red green) indication of
control resultsbull LED sensor of hand- positioning for start of
measurementbull Audible alarm signals of the excess of preset
thresholdsbull Measurement value indication min-1cm-2 or
Bqсm2
Physical characteristicsDetectors alpha - scintillatior ZnS(Ag)
Efficiencybull Pu-239 20 bull U-234 14bull U-238 8
Measurement range bull 05 divide 105 min-1cm-2
Energy range bull 41 divide 90 MeV
Operation temperature range bull minus 10 divide +50 ordmС
Electrical characteristicsPower supply bull 220 V 50 Hz
Mechanical characteristicsOverall dimensions weight no more bull 740times1400times1450 mm 70 kg
Reference standards Nuclear IEC 61098
bull Simultaneous measurement of alphabeta activi-ties in the sample
bull Active shielding anti-coincidence background subtraction using GM counters
bull Lead shielding 30 mm
UMF-2000 LOW LEVEL ALPHA- BETA- COUNTER
Physical characteristicsDetectors bull Silicon specrometric detector 500 or 1000 mm2
Measurement range bull Alpha 001 divide 1000 Bq bull Beta 01 divide 3000 Bq
Energy range bull Alpha 35 divide 80 MeV bull Beta 005 divide 35 MeV
Electrical characteristicsPower supply bull 220 V 50 Hz
Interfaces bull RS-232bull USB
Mechanical characteristicsOverall dimensions weight bull 337times286times190 mm 22 kg
Versionsbull Detector area 500 mm2
bull Detector area 1000 mm2
UMF-2000 Detector area 1000 mm2
UMF-2000 Detector area 500 mm2
SpectraDec software for alpha-spectrometric measurements
SPC ldquoDozardquoRadiation monitoring equipment
64 65
DRK DOSE AREA PRODUCT METER
DRK-1bull Diagnostic reference level (DRL) of patients
determinationbull Suitable for all basic types of x-ray machines
Physical characteristicsDetector bull Plane-parallel ionization chamber
Measurement range bull 1 divide 104 cGycm2
Electrical characteristicsPower supply bull 220 V 50 Hz
DRK-1M-CTbull Measuring of dose length product
Physical characteristicsDetector bull Pencil Ionization Chamber
Measurement rangebull 05 divide 109 microGym
DRK-1Mbull Measuring of air kerma on sectional area of the
X-ray beam productbull Measuring of air kerma rate on area productbull Measuring of air kerma ratebull Measuring of air kerma
Physical characteristicsDetector bull Plane-parallel ionization chamber
Measurement rangebull 01 divide 109 microGym2
bull 06 divide 6104 microGym2cbull 30 divide 9105 microGycbull 30 divide 9991011 microGyReference standard IEC 60580 2003
bull Measurement of strontium-90 in the foodstuffs agricultural products etc
bull Measurement of gross beta activity in samplebull Self tests using built-in LED
ldquoPROGRESS-BETArdquo SCINTILLATION BETA SPECTROMETER
Physical characteristicsDetector bull Plastic scintillator Oslash70x10 mm
Sample bull Plate Oslash70 mmbull Weight up to 15 g
Energy range bull 02 divide 30 MeV
Minimum detectable activity of Sr-90 in a 10 g sample on a standard planchet Bqsamplebull In case of absence of K-40 in the sample 01 Bqbull In case the activity of K-40 till 5 Bqg 05 Bq
Electrical characteristics Interface bull USB
Mechanical characteristicsWeight bull No more 50 kg
Complete setBasic complete setbull Detector unit with plastic scintillator integrated
power supply amplifier ADC bull Lead shielding bull ldquoProgressrdquo software bull Сheck source for energetic calibration (Sr-90-Y-90) bull Planchet Oslash 70 mm (5 items) bull Sample dencification device bull Procedure manual for measurement of radio-
nuclidesrsquo activity using the scintillation beta spec-trometer ldquoProgressrdquo
Optional equipment and servicebull Personal computer and printer bull Calibrations for radionuclides not included in the
main library of radionuclides
Progress-Beta
Reference standards IEC 61562
SPC ldquoDozardquoRadiation monitoring equipment
66 67
bull Measurement of gamma activity in foodstuffs soil samples and others environmental objects
bull Identification of radionuclides in the sample bull Automatic correction for sample density bull Self-tests using built-in LED
ldquoPROGRESS-GAMMArdquoSCINTILLATION GAMMA SPECTROMETER
Physical characteristicsDetector bull NaI (Tl) Oslash63times63 mm
Validated measurement geometries bull Marinelli beakers (1 liter) Petri dishes (Oslash90 mm)
etc
Energy range bull 02 divide 30 MeV
Minimum detectable activity Bqsamplebull Cs-137 3 Bqbull Th-232 7 Bqbull Ra-226 8 Bq bull К-40 40 Bq
Electrical characteristics Interface bull USB
Mechanical characteristicsWeight bull No more 120 kg
Complete setBasic complete setbull Scintillation detector unit with NaI (Tl) detector
with integrated power supply amplifier and ADC bull Lead shielding 50 mm bull ldquoProgressrdquo software bull Сheck source for energy calibration (Cs-137 +
K-40)bull Marinelli beakers - 1 liter (5 items) bull Petri dishes Oslash 90 mm (5 items) bull Procedure manual for measurement of activity
of radionuclides using the scintillation gamma spectrometer ldquoProgressrdquo
Optional equipment and servicebull Kit for radon measurements including calibration
of ldquoIC-63rdquo geometry for counting the charcoal samples
bull Personal computer and printer bull Calibrations for user defined geometries bull Calibrations for radionuclides not included in the
main library of radionuclides
Progress-Gamma
Reference standards IEC 61563
ldquoPROGRESS-G(P)rdquoPORTABLE SCINTILLATION GAMMA SPECTROMETERbull Field measurements of gamma activity in environ-
mental objects without sampling (4π geometry)bull Laboratory measurement of gamma activity in
foodstuffs soil samples and others environmental objects
bull Identification of radionuclides in the sample bull Automatic correction for sample densitybull Tests using built-in LED
Physical charachteristicsDetector bull NaI (Tl) Oslash45times50 mmbull Lead shielding 20 mm
Validated measurement geometries bull Marinelli beakers (05 liter) Petri dishes (Oslash90 mm)
etc
Energy range bull 02 divide 30 MeV
Minimum detectable activity in 05-litre Marinelli beaker bull Cs-13710 Bqkgbull К-40100 Bqkgbull Ra-22618 Bqkg bull Th-23216 Bqkg
Minimum detectable activity in 30 min (4π geometry) bull Cs-137 2 Bqkgbull К-40 30 Bqkgbull Ra-226 4 Bqkg bull Th-232 3 Bqkg
Electrical characteristicsPower supply bull Rechargeable batterybull 220 V 50 Hz
Interface bull USB RS-232
Weight bull No more than 60 kg
Complete setBasic complete setbull Scinttillation detector unit with NaI(Tl) bull ldquoProgressrdquo softwarebull Сontrol unit ldquoSputnikrdquo for aquisition and analisys
of spectra with built-in memory for spectral databull Casebull Lead shielding (2 cm) for laboratory usebull 05-litre Marinelli beakers ndash 5 itemsbull Na-22 check sourcebull Power adapter BPS-01bull Operation manualbull Procedure manual for measurement of activity
of radionuclides using the scintillation gamma spectrometer ldquoProgressrdquo
Optional equipment and servicebull Kit for radon measurements with charcoalbull Built-in dose rate meterbull Additional memory (RAM) for storage of 64
spectrabull Additional power adapterbull Notebook and printer
Progress-Gamma
Reference standards IEC 61563
SPC ldquoDozardquoRadiation monitoring equipment
68 69
Physical characteristicsDetectorbull Scintillation detector ZnS (Oslash 60 mm)
Samplebull Thin sample - diameter up to 70 mm bull Preparation technique - electro-depositionbull Thick sample - diameter 70 mm weight
200300 mg bull Preparation technique - application of powders
(prepared by radiochemical concentration by water evaporation or by pounding of mineral samples) onto a planchet with the help of spirit
Energy rangebull 15 divide 8 MeV
Minimum detectable activitybull Thin samples no more than 910-3 Bqsamplebull Thick samples no more than 180 Bqkg
Mechanical characteristicsOverall dimensions weightbull 195times120times210 mm 34 kg
Complete setBasic complete setbull Alpha radiometer ldquoProgress-ARrdquobull Check source (uranium isotopes)
Set of accessoriesbull Procedure manual for measurements of radi-
oactivity using scintillation alpha radiometer ldquoProgress-ARrdquo
bull ldquoProgressrdquo software
ldquoProgress-ARrdquo
bull Measurement of gross activity of alpha emitting radionuclides in thin samples
bull Measurement of gross activity of alpha emitting radionuclides in thick samples
bull Measurement of activity deposited on aerosol filters
ldquoPROGRESS-ARrdquoALPHA RADIOMETER
Several fixed positions of the detector enable to perform measurements in various geometries and to estimate the content ofbull Cs-137 in the whole bodybull I-131 in thyroidbull Co-60 Cs-137 Mn-54 Cr-51 in lungsbull Database for storage of measurement data and
resultsbull Uncertainty calculations based on measurement
databull Self tests using built-in LED
ldquoPROGRESSrdquo WHOLE BODY COUNTER
Physical characteristicsDetectorbull scintillation detector NaI (Tl) Oslash63times63 mm
Energy rangebull 02 divide 28 MeV
Minimum detectable activitybull By Cs-137 in the whole body - 1200 Bqbull By I-131 in thyroid - 100 Bqbull By Co-60 Cs-137 Mn-54 Cr-51 in lungs - 200 Bq
Mechanical characteristicsWeight bull No more than 120 kg
Complete setBasic complete setbull Collimator with rotator and holderbull Detector with incorporated ADCbull Patient chair and table for collimatorbull Check source Na-22bull Procedure manual for lifetime measurement of
gamma-emitting radionuclidesrsquo activity in human body using the gamma-spectrometer of human radiation ldquoProgressrdquo
bull laquoProgressraquo software
Optional equipment and servicebull Program of internal radiation committed internal
radiation effective dose calculation by the stand-ard model
bull Background phantombull Personal computer and printer
Collimator with rotator and holder
SPC ldquoDozardquoRadiation monitoring equipment
70 71
bull Categorization of wastes for the purpose of fur-ther processing including wastes with unknown radionuclide composition
bull Measurements during the incoming waste inspec-tion (accepting for storage disposal)
bull Certification of unconditioned and conditioned wastes in closed containers without opening them (at nuclear plants or at facilities providing collection storage transportation conditioning processing temporal storage and final disposal of radioactive waste)
bull Activity measurement of extended objects in situ without opening the equipment
bull Activity measurement of extended objects after opening (for example assessment of tubes used for oil transportation)
MKG-01D ldquoSADOVNIKrdquoSPECTROMETRY SYSTEM
Physical charachteristicsDetectorbull Detector unit GEM (GMX) with HPGe detector and
multi-positioning cryostat CFG-PMOD4-7 with 7 litre Dewar
bull Dose rate probe BDMG-200
Energy range bull With GEM detector 004 divide 30 MeVbull With GMX detector 0005 divide 15 MeVbull Dose rate probe BDMG-200 ndash 005 divide 30 MeV
Measurement rangebull 110-7 divide 10 Svhbull Relative efficiency of detection (in photopeak) at
13325 MeV (Co-60) 10 divide 150
Electrical characteristicsPower supplybull 220 V 50 Hz
Interfacebull USB
Complete setBasic complete setbull Spectrometric detector unit GEM (GMX) with
HPGe detector and multi-positioning cryostat with 7 litre Dewar
bull Portable digital multichannel analyzer DigiDARTbull Dose rate probe BDMG-200bull Autonomous power supply unit with built-in
batterybull Industrial computer keyboardbull Laser range-finderbull Thermographic printerbull Web-camerabull Device equipped with stepper motor for position-
ing of the spectrometric detectorbull Calibration device with reference sources
(Am-241 Co-60 Ba-133 Eu-152) for energy calibration
bull Removable collimators with end capbull Measurement proceduresbull ldquoClasterrdquo software
bull Measurement of gross alpha activity of alpha-emitting radionuclides
bull Measurement of alpha-emitting radionuclides activity in thin-layer samples meeting alpha-spectrometry requirements
Physical characteristicsDetectorbull Silicon ion-implanted 450 mm2
bull Easy to decontaminate thin windowbull dead layer less than 015 μmbull Background count rate in the range 3 divide 9 MeVbull No more than 09 h-1cm-2 for 450 mm2 detector
Energy rangebull 2 divide 9 MeVbull Lower limit of measurement range (minimum
detectable activity) 01 Bqbull Background count rate no more than 100 counts
in 24 hours
Electrical characteristics Power supplybull 220 V 50 Hz
Interfacebull USB
Complete setBasic complete setbull Detector unit with vacuum measuring chamber
and vacuum control systembull Low noise vacuum pump (type 2FY-05B or
equivalent)bull Check sourcebull ldquoProgressrdquo softwarebull Vacuum tube
MKS-01A ldquoMULTIRAD-ASrdquoALPHA SPECTROMETER
SPC ldquoDozardquoRadiation monitoring equipment
72 73
UCRV-2AIRFLOW MONITOR
bull Monitor of the air flow through filter of centralized multichannel sampling system
bull Radiation monitoring system (RMS) integration for internal exposures determination
bull Volume and flow rate measurements of the air that have passed through a analytical filter
bull Bar-code for filter identificationbull Operation as either standalone unit or as a part of
the RMS
Physical characteristicsMeasurement range of air volume bull 001 divide 9999 m3
Operation temperature range bull minus 20 divide +50 ordmС
Electrical characteristicsPower supply bull 220 V 50 Hz
Interface bull RS-485
PVP-06PORTABLE AIR SAMPLER
Air Sampler PVP-06 is indispensable for monitoring the radiation situation where the concentration of radioactive aerosols in the air does not require a sta-tionary sampling equipment Sampling head PVP-06 provides easy change of filters and cartridges
Purposebull To monitor the concentration of radioactive aero-
sols in the air sites
Controlled aerosolsbull Alpha- and beta-active aerosolsbull Daughter products of decay of radon and thoronbull Iodine isotopes
Physical characteristicsTypes of filtersbull Aerosol AFA-RSP-20bull Iodine AFA SI-20
Flow rate bull 33∙10-4 ndash 233∙10-4 m3s (20 divide 140 l min)
Electrical characteristicsPower supply bull 220 V50 Hzbull The vehicle power supply 108 divide 145 Vbull Internal battery
Minimal working time on internal battery to recharge bull 8 hours
Power consumption (at a flow rate of 100 lmin) bull 40 VA
Environment characteristicsOperating temperature bull minus 10 divide +40 deg C
Maximum humidity bull 90
Pressure bull 860 to 1060 hPA
Noise generated by the pump bull lt 55 dBA at 1 m
Mechanical characteristicsDimensions weight bull 241 times 108 times 160 mm 28 kg
Case material bull Plastic
Complete setbull Air sampler PVP-06bull AC power adapterbull Filters AFA-RSP-20 - 100 pcsbull Packaging for filters - 40 pcsbull Casebull Operation manualbull Calibration certificate
Optional equimpient bull Kit for sampling sorption columns of activated
carbon Ř head of sorption columns with protective
covers Ř activated charcoal SKT-3 - 1 pkg (02 L) Ř charocoal samples SC-13 - 8 pcs
bull Car charger bull Tipod bull Shoulder strapbull Calibration stand bull Filters AFA SI-20 - 100 pcs
Consumablesbull Aerosol filters AFA RSP-20bull Iodine filters AFA SI-20
SPC ldquoDozardquoRadiation monitoring equipment
74 75
Calibration of gamma dose and dose rate meters
Calibration ofbull Ambient equivalent dose H(10) meters (Sv Svh)bull Personal equivalent dose Hp(10) meters (Sv Svh)bull Exposure dose X meters (R Rh)bull Two sources in irradiator bull Select source and collimator opening using
tumbler
UPG-P DESKTOP GAMMA BEAM IRRADIATOR
Physical characteristicsRange of reproduced dose rate bull 05 μSvh divide 10 mSvh (50 μRh divide 100 mRh)
Sources activities bull 6times106 6times108 Bq (02 20 mCi) Cs-137
Overall dimensions bull 1250times400times300 mm
Irradiator weight bull Not more than 37 kg
Calibration bench weight bull Not more than 15 kg
Reference standards IEC 60846 IEC 61526
Physical characteristicsDetectorbull Silicon
Measurement range EEC measurement bull Measurement range of radon EEC
10 divide 10bull106 Bqbullm-3
bull Measurement range of thoron EEC 05 divide 10bull104 Bqbullm-3
bull Air flow through the filter 100plusmn05 lmin
Concentration measurementbull Measurement range of radon-222 concentration
in air 10 divide 20bull106 cpsbull Measurement range of 216Po(ThA)
1bull10-3 divide 1bull102 cpsbull Air sampler flow rate
10plusmn02 lminbull Measurement range of radon-222 concentration
in water samples 6 divide 800 Bqbullkg-1
bull Measurement range of radon-222 flux from soil surface 20 divide 103 mBqsbullm2
bull Measurement range of radon-222 concentration with preliminary sampling of air using air sam-plers 20 divide 107 Bqbullm-3
bull Measurement range of radon-222 concentration in samples of soil air 103 divide 106 Bqbullm-3
Operation temperature range bull 1 divide 35 ordmC
Electrical characteristicsPower supply bull 80 VA
Mechanical characteristicsOverall dimensions weight bull 220times200times165 mm 36 kg
ldquoALPHARAD PLUSrdquoRADON THORON amp THEIR PROGENY MONITORbull Measurement of radon and thoron concentration
and effective equivalent concentration (EEC)bull In the airbull In the indoor air of residential public and industri-
al buildings and structuresbull Measurement of radon in drinking water sourcesbull Measurements of radon flux from the soil surface
at land plots allocated for construction of houses public buildings and industrial facilities
bull Measurements of radon concentration in soil air
Reference standards IEC 61577
SPC ldquoDozardquoRadiation monitoring equipment
76 77
UKPN-2M-D NEUTRON BEAM IRRADIATOR
Reference standards IEC 61005 61322
Calibration of neutron dose and dose rate meters
Calibration ofbull Ambient equivalent dose H(10) meters (Sv Svh)bull Personal equivalent dose Hp(10) meters (Sv Svh)bull Flux density of neutrons (cm-2∙s-1)bull Transfer container for temporary storage of
sources bull Red light signal of source working position
Physical carachteristicsRange of reproduced dose ratebull 20 divide 800 μSvh
Range of reproduced flux densitiesbull 10 divide 400 cm-2∙s-1
Type of a source in use bull Pu-Be
Activity of a source in usebull 24х1011 Bq (with density of 107 s-1)
Overall dimensions weight no morebull 3000x750x2000 mm 300 kg
Required room dimensionsbull not less than 7x3x3 m
Electrical characteristicsPower supply bull 220 V 50 Hz
Calibration of gamma dose and dose rate meters
Calibration ofbull Ambient equivalent dose H(10) meters (Sv Svh)bull Personal equivalent dose Hp(10) meters (Sv Svh)bull Exposure dose X meters (R Rh)bull Four sources in irradiator bull Select source and move to working position
return to storage position using special rodbull Transfer container for temporary storage of
sources bull Red light signal of source working position
UPGD-2M-DGAMMA BEAM IRRADIATOR
Physical characteristicsRange of reproduced dose rate bull 05 μSvh divide 50 mSvh (50 μRh divide 5 Rh)
Maximum activity of source bull 2times1011 Bq (50 Ci) Cs-137
Overall dimensionsbull Irradiator 800times500times500 mmbull Guide rails length 30 mbull Height 16 mbull Weight not more than 700 kgbull Required room dimensions not less than 7x3x3 m
Electrical characteristicsPower supply bull 220 V 50 Hz
UPGD-2M-D
Reference standards IEC 60846 IEC 61526 IEC 61066
SPC ldquoDozardquo
78 79
Contents
MEASURING UNITS
DBG-S11D wide range gamma area monitor 40
UDKS-100 gamma and X-ray area monitor 41
UDMN-100 neutron area monitor 41
ALARM UNITS
BAS-2 ldquoMICROrdquo external visual alarm 42
BZS-2 ldquoMicrordquo external audible alarm 42
Illuminated warning signs 43
ldquoImpulsrdquo external display unit 43
UIM-3D area monitor count rate meter 44
DKG-05D personal gamma dosimeter 46
DVS-02D gamma-neutron personal electronic dosimeter 47
DVGI-8D new pen-type personal ionization chamber dosimeters 48
DKG-02U ldquoARBITERrdquo wide range gamma-dosimeter 49
DKG-07D ldquoDROZDrdquo gamma-dosimeter 50
MKS-15D ldquoSNEGIRrdquo multi ndash purpose radiation survey meter 51
SRPS-05D gamma monitor 52
DOZA-TLD multipurpose TLD system 53
DKS-96 universal radiation survey meter 54
EXTERNAL PROBES ALPHA
Alpha BDZA-96 55
Alpha BDZA-96B 55
Alpha BDZA-96M 55
Alpha BDZA-96S 55
Alpha BDZA-96T 55
EXTERNAL PROBES BETA
Beta BDZB-96 56
Beta BDZB-99 56
Beta BDZB-96B 56
Beta BDZB-96S 56
EXTERNAL PROBES GAMMA
Gamma BDKS-96B 57
Gamma and beta BDKS-96S 57
Gamma BDMG-96 57
EXTERNAL PROBES GAMMA
Gamma-search BDVG-96 58
Gamma-search BDPG-96 58
ContentsRadiation monitoring systemldquoPELIKANrdquo Radiation monitoring system (RMS) 6
BDMG-101 high range gamma area monitor 10
DBG-S11D wide range gamma area monitor 11
BDRG-52 high range gamma area monitor for accident and post-accident conditions 12
UDGP-01 Liquid technological environments monitor 13
UDMN-100 neutron area monitor 14
UDKG-100 Wel Liquid gamma monitor 14
BOP-1M data processing and transmission unit 15
UDA-1AB particulate monitor 16
UDG-1B noble gas monitor 17
UDG-03D noble gas monitor 18
UDI-1B iodine monitor 19
UDGB-01 noble gasesH-3C-14 monitor 20
UDGP-01 steam generator leakage monitor 21
UPPVM air flow parameters monitor 22
ldquoIMPULSrdquo external display unit 23
BI-2 remote display amp alarm unit 24
BASBAS-1s external alarm 25
SKGAV stack monitor 26
RMS software 28
RMS workstation ndash operator console 29
Configurator software 29
RM RACK radiation monitoring rack 30
SRKS-01D criticality accident alarm system 32
ldquoATLANT-Mrdquo environmental radiation monitoring system 34
ldquoBREEZErdquo high-volume air sampler 35
ldquoGAMMA-SENSORrdquo gamma-survey system 36
Radiation monitoring equipmentAREA MONITOR ldquoFREGATrdquo 38
BPI-1D local display unit 39
80
Gamma-search BDPG-96M 58
Gamma BDKG-96 stainless steel casing for geologic applications well logging 59
EXTERNAL PROBES NEUTRON
Neutron BDMN-96 59
Neutron-search BDKN-96 59
RZB-05D Hand-foot-clothing monitor 60
RZBA-04-04M whole body contamination monitor 61
RZA-05D alpha hand-monitor 62
UMF-2000 low level alpha- beta- counter 63
DRK dose area product meter 64
ldquoPROGRESS-BETArdquo scintillation beta spectrometer 65
ldquoPROGRESS-GAMMArdquo scintillation gamma spectrometer 66
ldquoPROGRESS-G(P)rdquo portable scintillation gamma spectrometer 67
ldquoPROGRESS-ARrdquo alpha radiometer 68
ldquoPROGRESSrdquo whole body counter 69
MKG-01D ldquoSADOVNIKrdquo spectrometry system 70
MKS-01A ldquoMULTIRAD-ASrdquo alpha spectrometer 71
UCRV-2 airflow monitor 72
PVP-06 portable air sampler 73
ldquoALPHARAD PLUSrdquo radon thoron amp their progeny monitor 74
UPG-P desktop gamma beam irradiator 75
UPGD-2M-D gamma beam irradiator 76
UKPN-2M-D neutron beam irradiator 77
SPC ldquoDozardquoRadiation monitoring equipment
62 63
RZA-05DALPHA HAND-MONITOR
bull No gas supply needed bull Numeric and color (red green) indication of
control resultsbull LED sensor of hand- positioning for start of
measurementbull Audible alarm signals of the excess of preset
thresholdsbull Measurement value indication min-1cm-2 or
Bqсm2
Physical characteristicsDetectors alpha - scintillatior ZnS(Ag)
Efficiencybull Pu-239 20 bull U-234 14bull U-238 8
Measurement range bull 05 divide 105 min-1cm-2
Energy range bull 41 divide 90 MeV
Operation temperature range bull minus 10 divide +50 ordmС
Electrical characteristicsPower supply bull 220 V 50 Hz
Mechanical characteristicsOverall dimensions weight no more bull 740times1400times1450 mm 70 kg
Reference standards Nuclear IEC 61098
bull Simultaneous measurement of alphabeta activi-ties in the sample
bull Active shielding anti-coincidence background subtraction using GM counters
bull Lead shielding 30 mm
UMF-2000 LOW LEVEL ALPHA- BETA- COUNTER
Physical characteristicsDetectors bull Silicon specrometric detector 500 or 1000 mm2
Measurement range bull Alpha 001 divide 1000 Bq bull Beta 01 divide 3000 Bq
Energy range bull Alpha 35 divide 80 MeV bull Beta 005 divide 35 MeV
Electrical characteristicsPower supply bull 220 V 50 Hz
Interfaces bull RS-232bull USB
Mechanical characteristicsOverall dimensions weight bull 337times286times190 mm 22 kg
Versionsbull Detector area 500 mm2
bull Detector area 1000 mm2
UMF-2000 Detector area 1000 mm2
UMF-2000 Detector area 500 mm2
SpectraDec software for alpha-spectrometric measurements
SPC ldquoDozardquoRadiation monitoring equipment
64 65
DRK DOSE AREA PRODUCT METER
DRK-1bull Diagnostic reference level (DRL) of patients
determinationbull Suitable for all basic types of x-ray machines
Physical characteristicsDetector bull Plane-parallel ionization chamber
Measurement range bull 1 divide 104 cGycm2
Electrical characteristicsPower supply bull 220 V 50 Hz
DRK-1M-CTbull Measuring of dose length product
Physical characteristicsDetector bull Pencil Ionization Chamber
Measurement rangebull 05 divide 109 microGym
DRK-1Mbull Measuring of air kerma on sectional area of the
X-ray beam productbull Measuring of air kerma rate on area productbull Measuring of air kerma ratebull Measuring of air kerma
Physical characteristicsDetector bull Plane-parallel ionization chamber
Measurement rangebull 01 divide 109 microGym2
bull 06 divide 6104 microGym2cbull 30 divide 9105 microGycbull 30 divide 9991011 microGyReference standard IEC 60580 2003
bull Measurement of strontium-90 in the foodstuffs agricultural products etc
bull Measurement of gross beta activity in samplebull Self tests using built-in LED
ldquoPROGRESS-BETArdquo SCINTILLATION BETA SPECTROMETER
Physical characteristicsDetector bull Plastic scintillator Oslash70x10 mm
Sample bull Plate Oslash70 mmbull Weight up to 15 g
Energy range bull 02 divide 30 MeV
Minimum detectable activity of Sr-90 in a 10 g sample on a standard planchet Bqsamplebull In case of absence of K-40 in the sample 01 Bqbull In case the activity of K-40 till 5 Bqg 05 Bq
Electrical characteristics Interface bull USB
Mechanical characteristicsWeight bull No more 50 kg
Complete setBasic complete setbull Detector unit with plastic scintillator integrated
power supply amplifier ADC bull Lead shielding bull ldquoProgressrdquo software bull Сheck source for energetic calibration (Sr-90-Y-90) bull Planchet Oslash 70 mm (5 items) bull Sample dencification device bull Procedure manual for measurement of radio-
nuclidesrsquo activity using the scintillation beta spec-trometer ldquoProgressrdquo
Optional equipment and servicebull Personal computer and printer bull Calibrations for radionuclides not included in the
main library of radionuclides
Progress-Beta
Reference standards IEC 61562
SPC ldquoDozardquoRadiation monitoring equipment
66 67
bull Measurement of gamma activity in foodstuffs soil samples and others environmental objects
bull Identification of radionuclides in the sample bull Automatic correction for sample density bull Self-tests using built-in LED
ldquoPROGRESS-GAMMArdquoSCINTILLATION GAMMA SPECTROMETER
Physical characteristicsDetector bull NaI (Tl) Oslash63times63 mm
Validated measurement geometries bull Marinelli beakers (1 liter) Petri dishes (Oslash90 mm)
etc
Energy range bull 02 divide 30 MeV
Minimum detectable activity Bqsamplebull Cs-137 3 Bqbull Th-232 7 Bqbull Ra-226 8 Bq bull К-40 40 Bq
Electrical characteristics Interface bull USB
Mechanical characteristicsWeight bull No more 120 kg
Complete setBasic complete setbull Scintillation detector unit with NaI (Tl) detector
with integrated power supply amplifier and ADC bull Lead shielding 50 mm bull ldquoProgressrdquo software bull Сheck source for energy calibration (Cs-137 +
K-40)bull Marinelli beakers - 1 liter (5 items) bull Petri dishes Oslash 90 mm (5 items) bull Procedure manual for measurement of activity
of radionuclides using the scintillation gamma spectrometer ldquoProgressrdquo
Optional equipment and servicebull Kit for radon measurements including calibration
of ldquoIC-63rdquo geometry for counting the charcoal samples
bull Personal computer and printer bull Calibrations for user defined geometries bull Calibrations for radionuclides not included in the
main library of radionuclides
Progress-Gamma
Reference standards IEC 61563
ldquoPROGRESS-G(P)rdquoPORTABLE SCINTILLATION GAMMA SPECTROMETERbull Field measurements of gamma activity in environ-
mental objects without sampling (4π geometry)bull Laboratory measurement of gamma activity in
foodstuffs soil samples and others environmental objects
bull Identification of radionuclides in the sample bull Automatic correction for sample densitybull Tests using built-in LED
Physical charachteristicsDetector bull NaI (Tl) Oslash45times50 mmbull Lead shielding 20 mm
Validated measurement geometries bull Marinelli beakers (05 liter) Petri dishes (Oslash90 mm)
etc
Energy range bull 02 divide 30 MeV
Minimum detectable activity in 05-litre Marinelli beaker bull Cs-13710 Bqkgbull К-40100 Bqkgbull Ra-22618 Bqkg bull Th-23216 Bqkg
Minimum detectable activity in 30 min (4π geometry) bull Cs-137 2 Bqkgbull К-40 30 Bqkgbull Ra-226 4 Bqkg bull Th-232 3 Bqkg
Electrical characteristicsPower supply bull Rechargeable batterybull 220 V 50 Hz
Interface bull USB RS-232
Weight bull No more than 60 kg
Complete setBasic complete setbull Scinttillation detector unit with NaI(Tl) bull ldquoProgressrdquo softwarebull Сontrol unit ldquoSputnikrdquo for aquisition and analisys
of spectra with built-in memory for spectral databull Casebull Lead shielding (2 cm) for laboratory usebull 05-litre Marinelli beakers ndash 5 itemsbull Na-22 check sourcebull Power adapter BPS-01bull Operation manualbull Procedure manual for measurement of activity
of radionuclides using the scintillation gamma spectrometer ldquoProgressrdquo
Optional equipment and servicebull Kit for radon measurements with charcoalbull Built-in dose rate meterbull Additional memory (RAM) for storage of 64
spectrabull Additional power adapterbull Notebook and printer
Progress-Gamma
Reference standards IEC 61563
SPC ldquoDozardquoRadiation monitoring equipment
68 69
Physical characteristicsDetectorbull Scintillation detector ZnS (Oslash 60 mm)
Samplebull Thin sample - diameter up to 70 mm bull Preparation technique - electro-depositionbull Thick sample - diameter 70 mm weight
200300 mg bull Preparation technique - application of powders
(prepared by radiochemical concentration by water evaporation or by pounding of mineral samples) onto a planchet with the help of spirit
Energy rangebull 15 divide 8 MeV
Minimum detectable activitybull Thin samples no more than 910-3 Bqsamplebull Thick samples no more than 180 Bqkg
Mechanical characteristicsOverall dimensions weightbull 195times120times210 mm 34 kg
Complete setBasic complete setbull Alpha radiometer ldquoProgress-ARrdquobull Check source (uranium isotopes)
Set of accessoriesbull Procedure manual for measurements of radi-
oactivity using scintillation alpha radiometer ldquoProgress-ARrdquo
bull ldquoProgressrdquo software
ldquoProgress-ARrdquo
bull Measurement of gross activity of alpha emitting radionuclides in thin samples
bull Measurement of gross activity of alpha emitting radionuclides in thick samples
bull Measurement of activity deposited on aerosol filters
ldquoPROGRESS-ARrdquoALPHA RADIOMETER
Several fixed positions of the detector enable to perform measurements in various geometries and to estimate the content ofbull Cs-137 in the whole bodybull I-131 in thyroidbull Co-60 Cs-137 Mn-54 Cr-51 in lungsbull Database for storage of measurement data and
resultsbull Uncertainty calculations based on measurement
databull Self tests using built-in LED
ldquoPROGRESSrdquo WHOLE BODY COUNTER
Physical characteristicsDetectorbull scintillation detector NaI (Tl) Oslash63times63 mm
Energy rangebull 02 divide 28 MeV
Minimum detectable activitybull By Cs-137 in the whole body - 1200 Bqbull By I-131 in thyroid - 100 Bqbull By Co-60 Cs-137 Mn-54 Cr-51 in lungs - 200 Bq
Mechanical characteristicsWeight bull No more than 120 kg
Complete setBasic complete setbull Collimator with rotator and holderbull Detector with incorporated ADCbull Patient chair and table for collimatorbull Check source Na-22bull Procedure manual for lifetime measurement of
gamma-emitting radionuclidesrsquo activity in human body using the gamma-spectrometer of human radiation ldquoProgressrdquo
bull laquoProgressraquo software
Optional equipment and servicebull Program of internal radiation committed internal
radiation effective dose calculation by the stand-ard model
bull Background phantombull Personal computer and printer
Collimator with rotator and holder
SPC ldquoDozardquoRadiation monitoring equipment
70 71
bull Categorization of wastes for the purpose of fur-ther processing including wastes with unknown radionuclide composition
bull Measurements during the incoming waste inspec-tion (accepting for storage disposal)
bull Certification of unconditioned and conditioned wastes in closed containers without opening them (at nuclear plants or at facilities providing collection storage transportation conditioning processing temporal storage and final disposal of radioactive waste)
bull Activity measurement of extended objects in situ without opening the equipment
bull Activity measurement of extended objects after opening (for example assessment of tubes used for oil transportation)
MKG-01D ldquoSADOVNIKrdquoSPECTROMETRY SYSTEM
Physical charachteristicsDetectorbull Detector unit GEM (GMX) with HPGe detector and
multi-positioning cryostat CFG-PMOD4-7 with 7 litre Dewar
bull Dose rate probe BDMG-200
Energy range bull With GEM detector 004 divide 30 MeVbull With GMX detector 0005 divide 15 MeVbull Dose rate probe BDMG-200 ndash 005 divide 30 MeV
Measurement rangebull 110-7 divide 10 Svhbull Relative efficiency of detection (in photopeak) at
13325 MeV (Co-60) 10 divide 150
Electrical characteristicsPower supplybull 220 V 50 Hz
Interfacebull USB
Complete setBasic complete setbull Spectrometric detector unit GEM (GMX) with
HPGe detector and multi-positioning cryostat with 7 litre Dewar
bull Portable digital multichannel analyzer DigiDARTbull Dose rate probe BDMG-200bull Autonomous power supply unit with built-in
batterybull Industrial computer keyboardbull Laser range-finderbull Thermographic printerbull Web-camerabull Device equipped with stepper motor for position-
ing of the spectrometric detectorbull Calibration device with reference sources
(Am-241 Co-60 Ba-133 Eu-152) for energy calibration
bull Removable collimators with end capbull Measurement proceduresbull ldquoClasterrdquo software
bull Measurement of gross alpha activity of alpha-emitting radionuclides
bull Measurement of alpha-emitting radionuclides activity in thin-layer samples meeting alpha-spectrometry requirements
Physical characteristicsDetectorbull Silicon ion-implanted 450 mm2
bull Easy to decontaminate thin windowbull dead layer less than 015 μmbull Background count rate in the range 3 divide 9 MeVbull No more than 09 h-1cm-2 for 450 mm2 detector
Energy rangebull 2 divide 9 MeVbull Lower limit of measurement range (minimum
detectable activity) 01 Bqbull Background count rate no more than 100 counts
in 24 hours
Electrical characteristics Power supplybull 220 V 50 Hz
Interfacebull USB
Complete setBasic complete setbull Detector unit with vacuum measuring chamber
and vacuum control systembull Low noise vacuum pump (type 2FY-05B or
equivalent)bull Check sourcebull ldquoProgressrdquo softwarebull Vacuum tube
MKS-01A ldquoMULTIRAD-ASrdquoALPHA SPECTROMETER
SPC ldquoDozardquoRadiation monitoring equipment
72 73
UCRV-2AIRFLOW MONITOR
bull Monitor of the air flow through filter of centralized multichannel sampling system
bull Radiation monitoring system (RMS) integration for internal exposures determination
bull Volume and flow rate measurements of the air that have passed through a analytical filter
bull Bar-code for filter identificationbull Operation as either standalone unit or as a part of
the RMS
Physical characteristicsMeasurement range of air volume bull 001 divide 9999 m3
Operation temperature range bull minus 20 divide +50 ordmС
Electrical characteristicsPower supply bull 220 V 50 Hz
Interface bull RS-485
PVP-06PORTABLE AIR SAMPLER
Air Sampler PVP-06 is indispensable for monitoring the radiation situation where the concentration of radioactive aerosols in the air does not require a sta-tionary sampling equipment Sampling head PVP-06 provides easy change of filters and cartridges
Purposebull To monitor the concentration of radioactive aero-
sols in the air sites
Controlled aerosolsbull Alpha- and beta-active aerosolsbull Daughter products of decay of radon and thoronbull Iodine isotopes
Physical characteristicsTypes of filtersbull Aerosol AFA-RSP-20bull Iodine AFA SI-20
Flow rate bull 33∙10-4 ndash 233∙10-4 m3s (20 divide 140 l min)
Electrical characteristicsPower supply bull 220 V50 Hzbull The vehicle power supply 108 divide 145 Vbull Internal battery
Minimal working time on internal battery to recharge bull 8 hours
Power consumption (at a flow rate of 100 lmin) bull 40 VA
Environment characteristicsOperating temperature bull minus 10 divide +40 deg C
Maximum humidity bull 90
Pressure bull 860 to 1060 hPA
Noise generated by the pump bull lt 55 dBA at 1 m
Mechanical characteristicsDimensions weight bull 241 times 108 times 160 mm 28 kg
Case material bull Plastic
Complete setbull Air sampler PVP-06bull AC power adapterbull Filters AFA-RSP-20 - 100 pcsbull Packaging for filters - 40 pcsbull Casebull Operation manualbull Calibration certificate
Optional equimpient bull Kit for sampling sorption columns of activated
carbon Ř head of sorption columns with protective
covers Ř activated charcoal SKT-3 - 1 pkg (02 L) Ř charocoal samples SC-13 - 8 pcs
bull Car charger bull Tipod bull Shoulder strapbull Calibration stand bull Filters AFA SI-20 - 100 pcs
Consumablesbull Aerosol filters AFA RSP-20bull Iodine filters AFA SI-20
SPC ldquoDozardquoRadiation monitoring equipment
74 75
Calibration of gamma dose and dose rate meters
Calibration ofbull Ambient equivalent dose H(10) meters (Sv Svh)bull Personal equivalent dose Hp(10) meters (Sv Svh)bull Exposure dose X meters (R Rh)bull Two sources in irradiator bull Select source and collimator opening using
tumbler
UPG-P DESKTOP GAMMA BEAM IRRADIATOR
Physical characteristicsRange of reproduced dose rate bull 05 μSvh divide 10 mSvh (50 μRh divide 100 mRh)
Sources activities bull 6times106 6times108 Bq (02 20 mCi) Cs-137
Overall dimensions bull 1250times400times300 mm
Irradiator weight bull Not more than 37 kg
Calibration bench weight bull Not more than 15 kg
Reference standards IEC 60846 IEC 61526
Physical characteristicsDetectorbull Silicon
Measurement range EEC measurement bull Measurement range of radon EEC
10 divide 10bull106 Bqbullm-3
bull Measurement range of thoron EEC 05 divide 10bull104 Bqbullm-3
bull Air flow through the filter 100plusmn05 lmin
Concentration measurementbull Measurement range of radon-222 concentration
in air 10 divide 20bull106 cpsbull Measurement range of 216Po(ThA)
1bull10-3 divide 1bull102 cpsbull Air sampler flow rate
10plusmn02 lminbull Measurement range of radon-222 concentration
in water samples 6 divide 800 Bqbullkg-1
bull Measurement range of radon-222 flux from soil surface 20 divide 103 mBqsbullm2
bull Measurement range of radon-222 concentration with preliminary sampling of air using air sam-plers 20 divide 107 Bqbullm-3
bull Measurement range of radon-222 concentration in samples of soil air 103 divide 106 Bqbullm-3
Operation temperature range bull 1 divide 35 ordmC
Electrical characteristicsPower supply bull 80 VA
Mechanical characteristicsOverall dimensions weight bull 220times200times165 mm 36 kg
ldquoALPHARAD PLUSrdquoRADON THORON amp THEIR PROGENY MONITORbull Measurement of radon and thoron concentration
and effective equivalent concentration (EEC)bull In the airbull In the indoor air of residential public and industri-
al buildings and structuresbull Measurement of radon in drinking water sourcesbull Measurements of radon flux from the soil surface
at land plots allocated for construction of houses public buildings and industrial facilities
bull Measurements of radon concentration in soil air
Reference standards IEC 61577
SPC ldquoDozardquoRadiation monitoring equipment
76 77
UKPN-2M-D NEUTRON BEAM IRRADIATOR
Reference standards IEC 61005 61322
Calibration of neutron dose and dose rate meters
Calibration ofbull Ambient equivalent dose H(10) meters (Sv Svh)bull Personal equivalent dose Hp(10) meters (Sv Svh)bull Flux density of neutrons (cm-2∙s-1)bull Transfer container for temporary storage of
sources bull Red light signal of source working position
Physical carachteristicsRange of reproduced dose ratebull 20 divide 800 μSvh
Range of reproduced flux densitiesbull 10 divide 400 cm-2∙s-1
Type of a source in use bull Pu-Be
Activity of a source in usebull 24х1011 Bq (with density of 107 s-1)
Overall dimensions weight no morebull 3000x750x2000 mm 300 kg
Required room dimensionsbull not less than 7x3x3 m
Electrical characteristicsPower supply bull 220 V 50 Hz
Calibration of gamma dose and dose rate meters
Calibration ofbull Ambient equivalent dose H(10) meters (Sv Svh)bull Personal equivalent dose Hp(10) meters (Sv Svh)bull Exposure dose X meters (R Rh)bull Four sources in irradiator bull Select source and move to working position
return to storage position using special rodbull Transfer container for temporary storage of
sources bull Red light signal of source working position
UPGD-2M-DGAMMA BEAM IRRADIATOR
Physical characteristicsRange of reproduced dose rate bull 05 μSvh divide 50 mSvh (50 μRh divide 5 Rh)
Maximum activity of source bull 2times1011 Bq (50 Ci) Cs-137
Overall dimensionsbull Irradiator 800times500times500 mmbull Guide rails length 30 mbull Height 16 mbull Weight not more than 700 kgbull Required room dimensions not less than 7x3x3 m
Electrical characteristicsPower supply bull 220 V 50 Hz
UPGD-2M-D
Reference standards IEC 60846 IEC 61526 IEC 61066
SPC ldquoDozardquo
78 79
Contents
MEASURING UNITS
DBG-S11D wide range gamma area monitor 40
UDKS-100 gamma and X-ray area monitor 41
UDMN-100 neutron area monitor 41
ALARM UNITS
BAS-2 ldquoMICROrdquo external visual alarm 42
BZS-2 ldquoMicrordquo external audible alarm 42
Illuminated warning signs 43
ldquoImpulsrdquo external display unit 43
UIM-3D area monitor count rate meter 44
DKG-05D personal gamma dosimeter 46
DVS-02D gamma-neutron personal electronic dosimeter 47
DVGI-8D new pen-type personal ionization chamber dosimeters 48
DKG-02U ldquoARBITERrdquo wide range gamma-dosimeter 49
DKG-07D ldquoDROZDrdquo gamma-dosimeter 50
MKS-15D ldquoSNEGIRrdquo multi ndash purpose radiation survey meter 51
SRPS-05D gamma monitor 52
DOZA-TLD multipurpose TLD system 53
DKS-96 universal radiation survey meter 54
EXTERNAL PROBES ALPHA
Alpha BDZA-96 55
Alpha BDZA-96B 55
Alpha BDZA-96M 55
Alpha BDZA-96S 55
Alpha BDZA-96T 55
EXTERNAL PROBES BETA
Beta BDZB-96 56
Beta BDZB-99 56
Beta BDZB-96B 56
Beta BDZB-96S 56
EXTERNAL PROBES GAMMA
Gamma BDKS-96B 57
Gamma and beta BDKS-96S 57
Gamma BDMG-96 57
EXTERNAL PROBES GAMMA
Gamma-search BDVG-96 58
Gamma-search BDPG-96 58
ContentsRadiation monitoring systemldquoPELIKANrdquo Radiation monitoring system (RMS) 6
BDMG-101 high range gamma area monitor 10
DBG-S11D wide range gamma area monitor 11
BDRG-52 high range gamma area monitor for accident and post-accident conditions 12
UDGP-01 Liquid technological environments monitor 13
UDMN-100 neutron area monitor 14
UDKG-100 Wel Liquid gamma monitor 14
BOP-1M data processing and transmission unit 15
UDA-1AB particulate monitor 16
UDG-1B noble gas monitor 17
UDG-03D noble gas monitor 18
UDI-1B iodine monitor 19
UDGB-01 noble gasesH-3C-14 monitor 20
UDGP-01 steam generator leakage monitor 21
UPPVM air flow parameters monitor 22
ldquoIMPULSrdquo external display unit 23
BI-2 remote display amp alarm unit 24
BASBAS-1s external alarm 25
SKGAV stack monitor 26
RMS software 28
RMS workstation ndash operator console 29
Configurator software 29
RM RACK radiation monitoring rack 30
SRKS-01D criticality accident alarm system 32
ldquoATLANT-Mrdquo environmental radiation monitoring system 34
ldquoBREEZErdquo high-volume air sampler 35
ldquoGAMMA-SENSORrdquo gamma-survey system 36
Radiation monitoring equipmentAREA MONITOR ldquoFREGATrdquo 38
BPI-1D local display unit 39
80
Gamma-search BDPG-96M 58
Gamma BDKG-96 stainless steel casing for geologic applications well logging 59
EXTERNAL PROBES NEUTRON
Neutron BDMN-96 59
Neutron-search BDKN-96 59
RZB-05D Hand-foot-clothing monitor 60
RZBA-04-04M whole body contamination monitor 61
RZA-05D alpha hand-monitor 62
UMF-2000 low level alpha- beta- counter 63
DRK dose area product meter 64
ldquoPROGRESS-BETArdquo scintillation beta spectrometer 65
ldquoPROGRESS-GAMMArdquo scintillation gamma spectrometer 66
ldquoPROGRESS-G(P)rdquo portable scintillation gamma spectrometer 67
ldquoPROGRESS-ARrdquo alpha radiometer 68
ldquoPROGRESSrdquo whole body counter 69
MKG-01D ldquoSADOVNIKrdquo spectrometry system 70
MKS-01A ldquoMULTIRAD-ASrdquo alpha spectrometer 71
UCRV-2 airflow monitor 72
PVP-06 portable air sampler 73
ldquoALPHARAD PLUSrdquo radon thoron amp their progeny monitor 74
UPG-P desktop gamma beam irradiator 75
UPGD-2M-D gamma beam irradiator 76
UKPN-2M-D neutron beam irradiator 77
SPC ldquoDozardquoRadiation monitoring equipment
64 65
DRK DOSE AREA PRODUCT METER
DRK-1bull Diagnostic reference level (DRL) of patients
determinationbull Suitable for all basic types of x-ray machines
Physical characteristicsDetector bull Plane-parallel ionization chamber
Measurement range bull 1 divide 104 cGycm2
Electrical characteristicsPower supply bull 220 V 50 Hz
DRK-1M-CTbull Measuring of dose length product
Physical characteristicsDetector bull Pencil Ionization Chamber
Measurement rangebull 05 divide 109 microGym
DRK-1Mbull Measuring of air kerma on sectional area of the
X-ray beam productbull Measuring of air kerma rate on area productbull Measuring of air kerma ratebull Measuring of air kerma
Physical characteristicsDetector bull Plane-parallel ionization chamber
Measurement rangebull 01 divide 109 microGym2
bull 06 divide 6104 microGym2cbull 30 divide 9105 microGycbull 30 divide 9991011 microGyReference standard IEC 60580 2003
bull Measurement of strontium-90 in the foodstuffs agricultural products etc
bull Measurement of gross beta activity in samplebull Self tests using built-in LED
ldquoPROGRESS-BETArdquo SCINTILLATION BETA SPECTROMETER
Physical characteristicsDetector bull Plastic scintillator Oslash70x10 mm
Sample bull Plate Oslash70 mmbull Weight up to 15 g
Energy range bull 02 divide 30 MeV
Minimum detectable activity of Sr-90 in a 10 g sample on a standard planchet Bqsamplebull In case of absence of K-40 in the sample 01 Bqbull In case the activity of K-40 till 5 Bqg 05 Bq
Electrical characteristics Interface bull USB
Mechanical characteristicsWeight bull No more 50 kg
Complete setBasic complete setbull Detector unit with plastic scintillator integrated
power supply amplifier ADC bull Lead shielding bull ldquoProgressrdquo software bull Сheck source for energetic calibration (Sr-90-Y-90) bull Planchet Oslash 70 mm (5 items) bull Sample dencification device bull Procedure manual for measurement of radio-
nuclidesrsquo activity using the scintillation beta spec-trometer ldquoProgressrdquo
Optional equipment and servicebull Personal computer and printer bull Calibrations for radionuclides not included in the
main library of radionuclides
Progress-Beta
Reference standards IEC 61562
SPC ldquoDozardquoRadiation monitoring equipment
66 67
bull Measurement of gamma activity in foodstuffs soil samples and others environmental objects
bull Identification of radionuclides in the sample bull Automatic correction for sample density bull Self-tests using built-in LED
ldquoPROGRESS-GAMMArdquoSCINTILLATION GAMMA SPECTROMETER
Physical characteristicsDetector bull NaI (Tl) Oslash63times63 mm
Validated measurement geometries bull Marinelli beakers (1 liter) Petri dishes (Oslash90 mm)
etc
Energy range bull 02 divide 30 MeV
Minimum detectable activity Bqsamplebull Cs-137 3 Bqbull Th-232 7 Bqbull Ra-226 8 Bq bull К-40 40 Bq
Electrical characteristics Interface bull USB
Mechanical characteristicsWeight bull No more 120 kg
Complete setBasic complete setbull Scintillation detector unit with NaI (Tl) detector
with integrated power supply amplifier and ADC bull Lead shielding 50 mm bull ldquoProgressrdquo software bull Сheck source for energy calibration (Cs-137 +
K-40)bull Marinelli beakers - 1 liter (5 items) bull Petri dishes Oslash 90 mm (5 items) bull Procedure manual for measurement of activity
of radionuclides using the scintillation gamma spectrometer ldquoProgressrdquo
Optional equipment and servicebull Kit for radon measurements including calibration
of ldquoIC-63rdquo geometry for counting the charcoal samples
bull Personal computer and printer bull Calibrations for user defined geometries bull Calibrations for radionuclides not included in the
main library of radionuclides
Progress-Gamma
Reference standards IEC 61563
ldquoPROGRESS-G(P)rdquoPORTABLE SCINTILLATION GAMMA SPECTROMETERbull Field measurements of gamma activity in environ-
mental objects without sampling (4π geometry)bull Laboratory measurement of gamma activity in
foodstuffs soil samples and others environmental objects
bull Identification of radionuclides in the sample bull Automatic correction for sample densitybull Tests using built-in LED
Physical charachteristicsDetector bull NaI (Tl) Oslash45times50 mmbull Lead shielding 20 mm
Validated measurement geometries bull Marinelli beakers (05 liter) Petri dishes (Oslash90 mm)
etc
Energy range bull 02 divide 30 MeV
Minimum detectable activity in 05-litre Marinelli beaker bull Cs-13710 Bqkgbull К-40100 Bqkgbull Ra-22618 Bqkg bull Th-23216 Bqkg
Minimum detectable activity in 30 min (4π geometry) bull Cs-137 2 Bqkgbull К-40 30 Bqkgbull Ra-226 4 Bqkg bull Th-232 3 Bqkg
Electrical characteristicsPower supply bull Rechargeable batterybull 220 V 50 Hz
Interface bull USB RS-232
Weight bull No more than 60 kg
Complete setBasic complete setbull Scinttillation detector unit with NaI(Tl) bull ldquoProgressrdquo softwarebull Сontrol unit ldquoSputnikrdquo for aquisition and analisys
of spectra with built-in memory for spectral databull Casebull Lead shielding (2 cm) for laboratory usebull 05-litre Marinelli beakers ndash 5 itemsbull Na-22 check sourcebull Power adapter BPS-01bull Operation manualbull Procedure manual for measurement of activity
of radionuclides using the scintillation gamma spectrometer ldquoProgressrdquo
Optional equipment and servicebull Kit for radon measurements with charcoalbull Built-in dose rate meterbull Additional memory (RAM) for storage of 64
spectrabull Additional power adapterbull Notebook and printer
Progress-Gamma
Reference standards IEC 61563
SPC ldquoDozardquoRadiation monitoring equipment
68 69
Physical characteristicsDetectorbull Scintillation detector ZnS (Oslash 60 mm)
Samplebull Thin sample - diameter up to 70 mm bull Preparation technique - electro-depositionbull Thick sample - diameter 70 mm weight
200300 mg bull Preparation technique - application of powders
(prepared by radiochemical concentration by water evaporation or by pounding of mineral samples) onto a planchet with the help of spirit
Energy rangebull 15 divide 8 MeV
Minimum detectable activitybull Thin samples no more than 910-3 Bqsamplebull Thick samples no more than 180 Bqkg
Mechanical characteristicsOverall dimensions weightbull 195times120times210 mm 34 kg
Complete setBasic complete setbull Alpha radiometer ldquoProgress-ARrdquobull Check source (uranium isotopes)
Set of accessoriesbull Procedure manual for measurements of radi-
oactivity using scintillation alpha radiometer ldquoProgress-ARrdquo
bull ldquoProgressrdquo software
ldquoProgress-ARrdquo
bull Measurement of gross activity of alpha emitting radionuclides in thin samples
bull Measurement of gross activity of alpha emitting radionuclides in thick samples
bull Measurement of activity deposited on aerosol filters
ldquoPROGRESS-ARrdquoALPHA RADIOMETER
Several fixed positions of the detector enable to perform measurements in various geometries and to estimate the content ofbull Cs-137 in the whole bodybull I-131 in thyroidbull Co-60 Cs-137 Mn-54 Cr-51 in lungsbull Database for storage of measurement data and
resultsbull Uncertainty calculations based on measurement
databull Self tests using built-in LED
ldquoPROGRESSrdquo WHOLE BODY COUNTER
Physical characteristicsDetectorbull scintillation detector NaI (Tl) Oslash63times63 mm
Energy rangebull 02 divide 28 MeV
Minimum detectable activitybull By Cs-137 in the whole body - 1200 Bqbull By I-131 in thyroid - 100 Bqbull By Co-60 Cs-137 Mn-54 Cr-51 in lungs - 200 Bq
Mechanical characteristicsWeight bull No more than 120 kg
Complete setBasic complete setbull Collimator with rotator and holderbull Detector with incorporated ADCbull Patient chair and table for collimatorbull Check source Na-22bull Procedure manual for lifetime measurement of
gamma-emitting radionuclidesrsquo activity in human body using the gamma-spectrometer of human radiation ldquoProgressrdquo
bull laquoProgressraquo software
Optional equipment and servicebull Program of internal radiation committed internal
radiation effective dose calculation by the stand-ard model
bull Background phantombull Personal computer and printer
Collimator with rotator and holder
SPC ldquoDozardquoRadiation monitoring equipment
70 71
bull Categorization of wastes for the purpose of fur-ther processing including wastes with unknown radionuclide composition
bull Measurements during the incoming waste inspec-tion (accepting for storage disposal)
bull Certification of unconditioned and conditioned wastes in closed containers without opening them (at nuclear plants or at facilities providing collection storage transportation conditioning processing temporal storage and final disposal of radioactive waste)
bull Activity measurement of extended objects in situ without opening the equipment
bull Activity measurement of extended objects after opening (for example assessment of tubes used for oil transportation)
MKG-01D ldquoSADOVNIKrdquoSPECTROMETRY SYSTEM
Physical charachteristicsDetectorbull Detector unit GEM (GMX) with HPGe detector and
multi-positioning cryostat CFG-PMOD4-7 with 7 litre Dewar
bull Dose rate probe BDMG-200
Energy range bull With GEM detector 004 divide 30 MeVbull With GMX detector 0005 divide 15 MeVbull Dose rate probe BDMG-200 ndash 005 divide 30 MeV
Measurement rangebull 110-7 divide 10 Svhbull Relative efficiency of detection (in photopeak) at
13325 MeV (Co-60) 10 divide 150
Electrical characteristicsPower supplybull 220 V 50 Hz
Interfacebull USB
Complete setBasic complete setbull Spectrometric detector unit GEM (GMX) with
HPGe detector and multi-positioning cryostat with 7 litre Dewar
bull Portable digital multichannel analyzer DigiDARTbull Dose rate probe BDMG-200bull Autonomous power supply unit with built-in
batterybull Industrial computer keyboardbull Laser range-finderbull Thermographic printerbull Web-camerabull Device equipped with stepper motor for position-
ing of the spectrometric detectorbull Calibration device with reference sources
(Am-241 Co-60 Ba-133 Eu-152) for energy calibration
bull Removable collimators with end capbull Measurement proceduresbull ldquoClasterrdquo software
bull Measurement of gross alpha activity of alpha-emitting radionuclides
bull Measurement of alpha-emitting radionuclides activity in thin-layer samples meeting alpha-spectrometry requirements
Physical characteristicsDetectorbull Silicon ion-implanted 450 mm2
bull Easy to decontaminate thin windowbull dead layer less than 015 μmbull Background count rate in the range 3 divide 9 MeVbull No more than 09 h-1cm-2 for 450 mm2 detector
Energy rangebull 2 divide 9 MeVbull Lower limit of measurement range (minimum
detectable activity) 01 Bqbull Background count rate no more than 100 counts
in 24 hours
Electrical characteristics Power supplybull 220 V 50 Hz
Interfacebull USB
Complete setBasic complete setbull Detector unit with vacuum measuring chamber
and vacuum control systembull Low noise vacuum pump (type 2FY-05B or
equivalent)bull Check sourcebull ldquoProgressrdquo softwarebull Vacuum tube
MKS-01A ldquoMULTIRAD-ASrdquoALPHA SPECTROMETER
SPC ldquoDozardquoRadiation monitoring equipment
72 73
UCRV-2AIRFLOW MONITOR
bull Monitor of the air flow through filter of centralized multichannel sampling system
bull Radiation monitoring system (RMS) integration for internal exposures determination
bull Volume and flow rate measurements of the air that have passed through a analytical filter
bull Bar-code for filter identificationbull Operation as either standalone unit or as a part of
the RMS
Physical characteristicsMeasurement range of air volume bull 001 divide 9999 m3
Operation temperature range bull minus 20 divide +50 ordmС
Electrical characteristicsPower supply bull 220 V 50 Hz
Interface bull RS-485
PVP-06PORTABLE AIR SAMPLER
Air Sampler PVP-06 is indispensable for monitoring the radiation situation where the concentration of radioactive aerosols in the air does not require a sta-tionary sampling equipment Sampling head PVP-06 provides easy change of filters and cartridges
Purposebull To monitor the concentration of radioactive aero-
sols in the air sites
Controlled aerosolsbull Alpha- and beta-active aerosolsbull Daughter products of decay of radon and thoronbull Iodine isotopes
Physical characteristicsTypes of filtersbull Aerosol AFA-RSP-20bull Iodine AFA SI-20
Flow rate bull 33∙10-4 ndash 233∙10-4 m3s (20 divide 140 l min)
Electrical characteristicsPower supply bull 220 V50 Hzbull The vehicle power supply 108 divide 145 Vbull Internal battery
Minimal working time on internal battery to recharge bull 8 hours
Power consumption (at a flow rate of 100 lmin) bull 40 VA
Environment characteristicsOperating temperature bull minus 10 divide +40 deg C
Maximum humidity bull 90
Pressure bull 860 to 1060 hPA
Noise generated by the pump bull lt 55 dBA at 1 m
Mechanical characteristicsDimensions weight bull 241 times 108 times 160 mm 28 kg
Case material bull Plastic
Complete setbull Air sampler PVP-06bull AC power adapterbull Filters AFA-RSP-20 - 100 pcsbull Packaging for filters - 40 pcsbull Casebull Operation manualbull Calibration certificate
Optional equimpient bull Kit for sampling sorption columns of activated
carbon Ř head of sorption columns with protective
covers Ř activated charcoal SKT-3 - 1 pkg (02 L) Ř charocoal samples SC-13 - 8 pcs
bull Car charger bull Tipod bull Shoulder strapbull Calibration stand bull Filters AFA SI-20 - 100 pcs
Consumablesbull Aerosol filters AFA RSP-20bull Iodine filters AFA SI-20
SPC ldquoDozardquoRadiation monitoring equipment
74 75
Calibration of gamma dose and dose rate meters
Calibration ofbull Ambient equivalent dose H(10) meters (Sv Svh)bull Personal equivalent dose Hp(10) meters (Sv Svh)bull Exposure dose X meters (R Rh)bull Two sources in irradiator bull Select source and collimator opening using
tumbler
UPG-P DESKTOP GAMMA BEAM IRRADIATOR
Physical characteristicsRange of reproduced dose rate bull 05 μSvh divide 10 mSvh (50 μRh divide 100 mRh)
Sources activities bull 6times106 6times108 Bq (02 20 mCi) Cs-137
Overall dimensions bull 1250times400times300 mm
Irradiator weight bull Not more than 37 kg
Calibration bench weight bull Not more than 15 kg
Reference standards IEC 60846 IEC 61526
Physical characteristicsDetectorbull Silicon
Measurement range EEC measurement bull Measurement range of radon EEC
10 divide 10bull106 Bqbullm-3
bull Measurement range of thoron EEC 05 divide 10bull104 Bqbullm-3
bull Air flow through the filter 100plusmn05 lmin
Concentration measurementbull Measurement range of radon-222 concentration
in air 10 divide 20bull106 cpsbull Measurement range of 216Po(ThA)
1bull10-3 divide 1bull102 cpsbull Air sampler flow rate
10plusmn02 lminbull Measurement range of radon-222 concentration
in water samples 6 divide 800 Bqbullkg-1
bull Measurement range of radon-222 flux from soil surface 20 divide 103 mBqsbullm2
bull Measurement range of radon-222 concentration with preliminary sampling of air using air sam-plers 20 divide 107 Bqbullm-3
bull Measurement range of radon-222 concentration in samples of soil air 103 divide 106 Bqbullm-3
Operation temperature range bull 1 divide 35 ordmC
Electrical characteristicsPower supply bull 80 VA
Mechanical characteristicsOverall dimensions weight bull 220times200times165 mm 36 kg
ldquoALPHARAD PLUSrdquoRADON THORON amp THEIR PROGENY MONITORbull Measurement of radon and thoron concentration
and effective equivalent concentration (EEC)bull In the airbull In the indoor air of residential public and industri-
al buildings and structuresbull Measurement of radon in drinking water sourcesbull Measurements of radon flux from the soil surface
at land plots allocated for construction of houses public buildings and industrial facilities
bull Measurements of radon concentration in soil air
Reference standards IEC 61577
SPC ldquoDozardquoRadiation monitoring equipment
76 77
UKPN-2M-D NEUTRON BEAM IRRADIATOR
Reference standards IEC 61005 61322
Calibration of neutron dose and dose rate meters
Calibration ofbull Ambient equivalent dose H(10) meters (Sv Svh)bull Personal equivalent dose Hp(10) meters (Sv Svh)bull Flux density of neutrons (cm-2∙s-1)bull Transfer container for temporary storage of
sources bull Red light signal of source working position
Physical carachteristicsRange of reproduced dose ratebull 20 divide 800 μSvh
Range of reproduced flux densitiesbull 10 divide 400 cm-2∙s-1
Type of a source in use bull Pu-Be
Activity of a source in usebull 24х1011 Bq (with density of 107 s-1)
Overall dimensions weight no morebull 3000x750x2000 mm 300 kg
Required room dimensionsbull not less than 7x3x3 m
Electrical characteristicsPower supply bull 220 V 50 Hz
Calibration of gamma dose and dose rate meters
Calibration ofbull Ambient equivalent dose H(10) meters (Sv Svh)bull Personal equivalent dose Hp(10) meters (Sv Svh)bull Exposure dose X meters (R Rh)bull Four sources in irradiator bull Select source and move to working position
return to storage position using special rodbull Transfer container for temporary storage of
sources bull Red light signal of source working position
UPGD-2M-DGAMMA BEAM IRRADIATOR
Physical characteristicsRange of reproduced dose rate bull 05 μSvh divide 50 mSvh (50 μRh divide 5 Rh)
Maximum activity of source bull 2times1011 Bq (50 Ci) Cs-137
Overall dimensionsbull Irradiator 800times500times500 mmbull Guide rails length 30 mbull Height 16 mbull Weight not more than 700 kgbull Required room dimensions not less than 7x3x3 m
Electrical characteristicsPower supply bull 220 V 50 Hz
UPGD-2M-D
Reference standards IEC 60846 IEC 61526 IEC 61066
SPC ldquoDozardquo
78 79
Contents
MEASURING UNITS
DBG-S11D wide range gamma area monitor 40
UDKS-100 gamma and X-ray area monitor 41
UDMN-100 neutron area monitor 41
ALARM UNITS
BAS-2 ldquoMICROrdquo external visual alarm 42
BZS-2 ldquoMicrordquo external audible alarm 42
Illuminated warning signs 43
ldquoImpulsrdquo external display unit 43
UIM-3D area monitor count rate meter 44
DKG-05D personal gamma dosimeter 46
DVS-02D gamma-neutron personal electronic dosimeter 47
DVGI-8D new pen-type personal ionization chamber dosimeters 48
DKG-02U ldquoARBITERrdquo wide range gamma-dosimeter 49
DKG-07D ldquoDROZDrdquo gamma-dosimeter 50
MKS-15D ldquoSNEGIRrdquo multi ndash purpose radiation survey meter 51
SRPS-05D gamma monitor 52
DOZA-TLD multipurpose TLD system 53
DKS-96 universal radiation survey meter 54
EXTERNAL PROBES ALPHA
Alpha BDZA-96 55
Alpha BDZA-96B 55
Alpha BDZA-96M 55
Alpha BDZA-96S 55
Alpha BDZA-96T 55
EXTERNAL PROBES BETA
Beta BDZB-96 56
Beta BDZB-99 56
Beta BDZB-96B 56
Beta BDZB-96S 56
EXTERNAL PROBES GAMMA
Gamma BDKS-96B 57
Gamma and beta BDKS-96S 57
Gamma BDMG-96 57
EXTERNAL PROBES GAMMA
Gamma-search BDVG-96 58
Gamma-search BDPG-96 58
ContentsRadiation monitoring systemldquoPELIKANrdquo Radiation monitoring system (RMS) 6
BDMG-101 high range gamma area monitor 10
DBG-S11D wide range gamma area monitor 11
BDRG-52 high range gamma area monitor for accident and post-accident conditions 12
UDGP-01 Liquid technological environments monitor 13
UDMN-100 neutron area monitor 14
UDKG-100 Wel Liquid gamma monitor 14
BOP-1M data processing and transmission unit 15
UDA-1AB particulate monitor 16
UDG-1B noble gas monitor 17
UDG-03D noble gas monitor 18
UDI-1B iodine monitor 19
UDGB-01 noble gasesH-3C-14 monitor 20
UDGP-01 steam generator leakage monitor 21
UPPVM air flow parameters monitor 22
ldquoIMPULSrdquo external display unit 23
BI-2 remote display amp alarm unit 24
BASBAS-1s external alarm 25
SKGAV stack monitor 26
RMS software 28
RMS workstation ndash operator console 29
Configurator software 29
RM RACK radiation monitoring rack 30
SRKS-01D criticality accident alarm system 32
ldquoATLANT-Mrdquo environmental radiation monitoring system 34
ldquoBREEZErdquo high-volume air sampler 35
ldquoGAMMA-SENSORrdquo gamma-survey system 36
Radiation monitoring equipmentAREA MONITOR ldquoFREGATrdquo 38
BPI-1D local display unit 39
80
Gamma-search BDPG-96M 58
Gamma BDKG-96 stainless steel casing for geologic applications well logging 59
EXTERNAL PROBES NEUTRON
Neutron BDMN-96 59
Neutron-search BDKN-96 59
RZB-05D Hand-foot-clothing monitor 60
RZBA-04-04M whole body contamination monitor 61
RZA-05D alpha hand-monitor 62
UMF-2000 low level alpha- beta- counter 63
DRK dose area product meter 64
ldquoPROGRESS-BETArdquo scintillation beta spectrometer 65
ldquoPROGRESS-GAMMArdquo scintillation gamma spectrometer 66
ldquoPROGRESS-G(P)rdquo portable scintillation gamma spectrometer 67
ldquoPROGRESS-ARrdquo alpha radiometer 68
ldquoPROGRESSrdquo whole body counter 69
MKG-01D ldquoSADOVNIKrdquo spectrometry system 70
MKS-01A ldquoMULTIRAD-ASrdquo alpha spectrometer 71
UCRV-2 airflow monitor 72
PVP-06 portable air sampler 73
ldquoALPHARAD PLUSrdquo radon thoron amp their progeny monitor 74
UPG-P desktop gamma beam irradiator 75
UPGD-2M-D gamma beam irradiator 76
UKPN-2M-D neutron beam irradiator 77
SPC ldquoDozardquoRadiation monitoring equipment
66 67
bull Measurement of gamma activity in foodstuffs soil samples and others environmental objects
bull Identification of radionuclides in the sample bull Automatic correction for sample density bull Self-tests using built-in LED
ldquoPROGRESS-GAMMArdquoSCINTILLATION GAMMA SPECTROMETER
Physical characteristicsDetector bull NaI (Tl) Oslash63times63 mm
Validated measurement geometries bull Marinelli beakers (1 liter) Petri dishes (Oslash90 mm)
etc
Energy range bull 02 divide 30 MeV
Minimum detectable activity Bqsamplebull Cs-137 3 Bqbull Th-232 7 Bqbull Ra-226 8 Bq bull К-40 40 Bq
Electrical characteristics Interface bull USB
Mechanical characteristicsWeight bull No more 120 kg
Complete setBasic complete setbull Scintillation detector unit with NaI (Tl) detector
with integrated power supply amplifier and ADC bull Lead shielding 50 mm bull ldquoProgressrdquo software bull Сheck source for energy calibration (Cs-137 +
K-40)bull Marinelli beakers - 1 liter (5 items) bull Petri dishes Oslash 90 mm (5 items) bull Procedure manual for measurement of activity
of radionuclides using the scintillation gamma spectrometer ldquoProgressrdquo
Optional equipment and servicebull Kit for radon measurements including calibration
of ldquoIC-63rdquo geometry for counting the charcoal samples
bull Personal computer and printer bull Calibrations for user defined geometries bull Calibrations for radionuclides not included in the
main library of radionuclides
Progress-Gamma
Reference standards IEC 61563
ldquoPROGRESS-G(P)rdquoPORTABLE SCINTILLATION GAMMA SPECTROMETERbull Field measurements of gamma activity in environ-
mental objects without sampling (4π geometry)bull Laboratory measurement of gamma activity in
foodstuffs soil samples and others environmental objects
bull Identification of radionuclides in the sample bull Automatic correction for sample densitybull Tests using built-in LED
Physical charachteristicsDetector bull NaI (Tl) Oslash45times50 mmbull Lead shielding 20 mm
Validated measurement geometries bull Marinelli beakers (05 liter) Petri dishes (Oslash90 mm)
etc
Energy range bull 02 divide 30 MeV
Minimum detectable activity in 05-litre Marinelli beaker bull Cs-13710 Bqkgbull К-40100 Bqkgbull Ra-22618 Bqkg bull Th-23216 Bqkg
Minimum detectable activity in 30 min (4π geometry) bull Cs-137 2 Bqkgbull К-40 30 Bqkgbull Ra-226 4 Bqkg bull Th-232 3 Bqkg
Electrical characteristicsPower supply bull Rechargeable batterybull 220 V 50 Hz
Interface bull USB RS-232
Weight bull No more than 60 kg
Complete setBasic complete setbull Scinttillation detector unit with NaI(Tl) bull ldquoProgressrdquo softwarebull Сontrol unit ldquoSputnikrdquo for aquisition and analisys
of spectra with built-in memory for spectral databull Casebull Lead shielding (2 cm) for laboratory usebull 05-litre Marinelli beakers ndash 5 itemsbull Na-22 check sourcebull Power adapter BPS-01bull Operation manualbull Procedure manual for measurement of activity
of radionuclides using the scintillation gamma spectrometer ldquoProgressrdquo
Optional equipment and servicebull Kit for radon measurements with charcoalbull Built-in dose rate meterbull Additional memory (RAM) for storage of 64
spectrabull Additional power adapterbull Notebook and printer
Progress-Gamma
Reference standards IEC 61563
SPC ldquoDozardquoRadiation monitoring equipment
68 69
Physical characteristicsDetectorbull Scintillation detector ZnS (Oslash 60 mm)
Samplebull Thin sample - diameter up to 70 mm bull Preparation technique - electro-depositionbull Thick sample - diameter 70 mm weight
200300 mg bull Preparation technique - application of powders
(prepared by radiochemical concentration by water evaporation or by pounding of mineral samples) onto a planchet with the help of spirit
Energy rangebull 15 divide 8 MeV
Minimum detectable activitybull Thin samples no more than 910-3 Bqsamplebull Thick samples no more than 180 Bqkg
Mechanical characteristicsOverall dimensions weightbull 195times120times210 mm 34 kg
Complete setBasic complete setbull Alpha radiometer ldquoProgress-ARrdquobull Check source (uranium isotopes)
Set of accessoriesbull Procedure manual for measurements of radi-
oactivity using scintillation alpha radiometer ldquoProgress-ARrdquo
bull ldquoProgressrdquo software
ldquoProgress-ARrdquo
bull Measurement of gross activity of alpha emitting radionuclides in thin samples
bull Measurement of gross activity of alpha emitting radionuclides in thick samples
bull Measurement of activity deposited on aerosol filters
ldquoPROGRESS-ARrdquoALPHA RADIOMETER
Several fixed positions of the detector enable to perform measurements in various geometries and to estimate the content ofbull Cs-137 in the whole bodybull I-131 in thyroidbull Co-60 Cs-137 Mn-54 Cr-51 in lungsbull Database for storage of measurement data and
resultsbull Uncertainty calculations based on measurement
databull Self tests using built-in LED
ldquoPROGRESSrdquo WHOLE BODY COUNTER
Physical characteristicsDetectorbull scintillation detector NaI (Tl) Oslash63times63 mm
Energy rangebull 02 divide 28 MeV
Minimum detectable activitybull By Cs-137 in the whole body - 1200 Bqbull By I-131 in thyroid - 100 Bqbull By Co-60 Cs-137 Mn-54 Cr-51 in lungs - 200 Bq
Mechanical characteristicsWeight bull No more than 120 kg
Complete setBasic complete setbull Collimator with rotator and holderbull Detector with incorporated ADCbull Patient chair and table for collimatorbull Check source Na-22bull Procedure manual for lifetime measurement of
gamma-emitting radionuclidesrsquo activity in human body using the gamma-spectrometer of human radiation ldquoProgressrdquo
bull laquoProgressraquo software
Optional equipment and servicebull Program of internal radiation committed internal
radiation effective dose calculation by the stand-ard model
bull Background phantombull Personal computer and printer
Collimator with rotator and holder
SPC ldquoDozardquoRadiation monitoring equipment
70 71
bull Categorization of wastes for the purpose of fur-ther processing including wastes with unknown radionuclide composition
bull Measurements during the incoming waste inspec-tion (accepting for storage disposal)
bull Certification of unconditioned and conditioned wastes in closed containers without opening them (at nuclear plants or at facilities providing collection storage transportation conditioning processing temporal storage and final disposal of radioactive waste)
bull Activity measurement of extended objects in situ without opening the equipment
bull Activity measurement of extended objects after opening (for example assessment of tubes used for oil transportation)
MKG-01D ldquoSADOVNIKrdquoSPECTROMETRY SYSTEM
Physical charachteristicsDetectorbull Detector unit GEM (GMX) with HPGe detector and
multi-positioning cryostat CFG-PMOD4-7 with 7 litre Dewar
bull Dose rate probe BDMG-200
Energy range bull With GEM detector 004 divide 30 MeVbull With GMX detector 0005 divide 15 MeVbull Dose rate probe BDMG-200 ndash 005 divide 30 MeV
Measurement rangebull 110-7 divide 10 Svhbull Relative efficiency of detection (in photopeak) at
13325 MeV (Co-60) 10 divide 150
Electrical characteristicsPower supplybull 220 V 50 Hz
Interfacebull USB
Complete setBasic complete setbull Spectrometric detector unit GEM (GMX) with
HPGe detector and multi-positioning cryostat with 7 litre Dewar
bull Portable digital multichannel analyzer DigiDARTbull Dose rate probe BDMG-200bull Autonomous power supply unit with built-in
batterybull Industrial computer keyboardbull Laser range-finderbull Thermographic printerbull Web-camerabull Device equipped with stepper motor for position-
ing of the spectrometric detectorbull Calibration device with reference sources
(Am-241 Co-60 Ba-133 Eu-152) for energy calibration
bull Removable collimators with end capbull Measurement proceduresbull ldquoClasterrdquo software
bull Measurement of gross alpha activity of alpha-emitting radionuclides
bull Measurement of alpha-emitting radionuclides activity in thin-layer samples meeting alpha-spectrometry requirements
Physical characteristicsDetectorbull Silicon ion-implanted 450 mm2
bull Easy to decontaminate thin windowbull dead layer less than 015 μmbull Background count rate in the range 3 divide 9 MeVbull No more than 09 h-1cm-2 for 450 mm2 detector
Energy rangebull 2 divide 9 MeVbull Lower limit of measurement range (minimum
detectable activity) 01 Bqbull Background count rate no more than 100 counts
in 24 hours
Electrical characteristics Power supplybull 220 V 50 Hz
Interfacebull USB
Complete setBasic complete setbull Detector unit with vacuum measuring chamber
and vacuum control systembull Low noise vacuum pump (type 2FY-05B or
equivalent)bull Check sourcebull ldquoProgressrdquo softwarebull Vacuum tube
MKS-01A ldquoMULTIRAD-ASrdquoALPHA SPECTROMETER
SPC ldquoDozardquoRadiation monitoring equipment
72 73
UCRV-2AIRFLOW MONITOR
bull Monitor of the air flow through filter of centralized multichannel sampling system
bull Radiation monitoring system (RMS) integration for internal exposures determination
bull Volume and flow rate measurements of the air that have passed through a analytical filter
bull Bar-code for filter identificationbull Operation as either standalone unit or as a part of
the RMS
Physical characteristicsMeasurement range of air volume bull 001 divide 9999 m3
Operation temperature range bull minus 20 divide +50 ordmС
Electrical characteristicsPower supply bull 220 V 50 Hz
Interface bull RS-485
PVP-06PORTABLE AIR SAMPLER
Air Sampler PVP-06 is indispensable for monitoring the radiation situation where the concentration of radioactive aerosols in the air does not require a sta-tionary sampling equipment Sampling head PVP-06 provides easy change of filters and cartridges
Purposebull To monitor the concentration of radioactive aero-
sols in the air sites
Controlled aerosolsbull Alpha- and beta-active aerosolsbull Daughter products of decay of radon and thoronbull Iodine isotopes
Physical characteristicsTypes of filtersbull Aerosol AFA-RSP-20bull Iodine AFA SI-20
Flow rate bull 33∙10-4 ndash 233∙10-4 m3s (20 divide 140 l min)
Electrical characteristicsPower supply bull 220 V50 Hzbull The vehicle power supply 108 divide 145 Vbull Internal battery
Minimal working time on internal battery to recharge bull 8 hours
Power consumption (at a flow rate of 100 lmin) bull 40 VA
Environment characteristicsOperating temperature bull minus 10 divide +40 deg C
Maximum humidity bull 90
Pressure bull 860 to 1060 hPA
Noise generated by the pump bull lt 55 dBA at 1 m
Mechanical characteristicsDimensions weight bull 241 times 108 times 160 mm 28 kg
Case material bull Plastic
Complete setbull Air sampler PVP-06bull AC power adapterbull Filters AFA-RSP-20 - 100 pcsbull Packaging for filters - 40 pcsbull Casebull Operation manualbull Calibration certificate
Optional equimpient bull Kit for sampling sorption columns of activated
carbon Ř head of sorption columns with protective
covers Ř activated charcoal SKT-3 - 1 pkg (02 L) Ř charocoal samples SC-13 - 8 pcs
bull Car charger bull Tipod bull Shoulder strapbull Calibration stand bull Filters AFA SI-20 - 100 pcs
Consumablesbull Aerosol filters AFA RSP-20bull Iodine filters AFA SI-20
SPC ldquoDozardquoRadiation monitoring equipment
74 75
Calibration of gamma dose and dose rate meters
Calibration ofbull Ambient equivalent dose H(10) meters (Sv Svh)bull Personal equivalent dose Hp(10) meters (Sv Svh)bull Exposure dose X meters (R Rh)bull Two sources in irradiator bull Select source and collimator opening using
tumbler
UPG-P DESKTOP GAMMA BEAM IRRADIATOR
Physical characteristicsRange of reproduced dose rate bull 05 μSvh divide 10 mSvh (50 μRh divide 100 mRh)
Sources activities bull 6times106 6times108 Bq (02 20 mCi) Cs-137
Overall dimensions bull 1250times400times300 mm
Irradiator weight bull Not more than 37 kg
Calibration bench weight bull Not more than 15 kg
Reference standards IEC 60846 IEC 61526
Physical characteristicsDetectorbull Silicon
Measurement range EEC measurement bull Measurement range of radon EEC
10 divide 10bull106 Bqbullm-3
bull Measurement range of thoron EEC 05 divide 10bull104 Bqbullm-3
bull Air flow through the filter 100plusmn05 lmin
Concentration measurementbull Measurement range of radon-222 concentration
in air 10 divide 20bull106 cpsbull Measurement range of 216Po(ThA)
1bull10-3 divide 1bull102 cpsbull Air sampler flow rate
10plusmn02 lminbull Measurement range of radon-222 concentration
in water samples 6 divide 800 Bqbullkg-1
bull Measurement range of radon-222 flux from soil surface 20 divide 103 mBqsbullm2
bull Measurement range of radon-222 concentration with preliminary sampling of air using air sam-plers 20 divide 107 Bqbullm-3
bull Measurement range of radon-222 concentration in samples of soil air 103 divide 106 Bqbullm-3
Operation temperature range bull 1 divide 35 ordmC
Electrical characteristicsPower supply bull 80 VA
Mechanical characteristicsOverall dimensions weight bull 220times200times165 mm 36 kg
ldquoALPHARAD PLUSrdquoRADON THORON amp THEIR PROGENY MONITORbull Measurement of radon and thoron concentration
and effective equivalent concentration (EEC)bull In the airbull In the indoor air of residential public and industri-
al buildings and structuresbull Measurement of radon in drinking water sourcesbull Measurements of radon flux from the soil surface
at land plots allocated for construction of houses public buildings and industrial facilities
bull Measurements of radon concentration in soil air
Reference standards IEC 61577
SPC ldquoDozardquoRadiation monitoring equipment
76 77
UKPN-2M-D NEUTRON BEAM IRRADIATOR
Reference standards IEC 61005 61322
Calibration of neutron dose and dose rate meters
Calibration ofbull Ambient equivalent dose H(10) meters (Sv Svh)bull Personal equivalent dose Hp(10) meters (Sv Svh)bull Flux density of neutrons (cm-2∙s-1)bull Transfer container for temporary storage of
sources bull Red light signal of source working position
Physical carachteristicsRange of reproduced dose ratebull 20 divide 800 μSvh
Range of reproduced flux densitiesbull 10 divide 400 cm-2∙s-1
Type of a source in use bull Pu-Be
Activity of a source in usebull 24х1011 Bq (with density of 107 s-1)
Overall dimensions weight no morebull 3000x750x2000 mm 300 kg
Required room dimensionsbull not less than 7x3x3 m
Electrical characteristicsPower supply bull 220 V 50 Hz
Calibration of gamma dose and dose rate meters
Calibration ofbull Ambient equivalent dose H(10) meters (Sv Svh)bull Personal equivalent dose Hp(10) meters (Sv Svh)bull Exposure dose X meters (R Rh)bull Four sources in irradiator bull Select source and move to working position
return to storage position using special rodbull Transfer container for temporary storage of
sources bull Red light signal of source working position
UPGD-2M-DGAMMA BEAM IRRADIATOR
Physical characteristicsRange of reproduced dose rate bull 05 μSvh divide 50 mSvh (50 μRh divide 5 Rh)
Maximum activity of source bull 2times1011 Bq (50 Ci) Cs-137
Overall dimensionsbull Irradiator 800times500times500 mmbull Guide rails length 30 mbull Height 16 mbull Weight not more than 700 kgbull Required room dimensions not less than 7x3x3 m
Electrical characteristicsPower supply bull 220 V 50 Hz
UPGD-2M-D
Reference standards IEC 60846 IEC 61526 IEC 61066
SPC ldquoDozardquo
78 79
Contents
MEASURING UNITS
DBG-S11D wide range gamma area monitor 40
UDKS-100 gamma and X-ray area monitor 41
UDMN-100 neutron area monitor 41
ALARM UNITS
BAS-2 ldquoMICROrdquo external visual alarm 42
BZS-2 ldquoMicrordquo external audible alarm 42
Illuminated warning signs 43
ldquoImpulsrdquo external display unit 43
UIM-3D area monitor count rate meter 44
DKG-05D personal gamma dosimeter 46
DVS-02D gamma-neutron personal electronic dosimeter 47
DVGI-8D new pen-type personal ionization chamber dosimeters 48
DKG-02U ldquoARBITERrdquo wide range gamma-dosimeter 49
DKG-07D ldquoDROZDrdquo gamma-dosimeter 50
MKS-15D ldquoSNEGIRrdquo multi ndash purpose radiation survey meter 51
SRPS-05D gamma monitor 52
DOZA-TLD multipurpose TLD system 53
DKS-96 universal radiation survey meter 54
EXTERNAL PROBES ALPHA
Alpha BDZA-96 55
Alpha BDZA-96B 55
Alpha BDZA-96M 55
Alpha BDZA-96S 55
Alpha BDZA-96T 55
EXTERNAL PROBES BETA
Beta BDZB-96 56
Beta BDZB-99 56
Beta BDZB-96B 56
Beta BDZB-96S 56
EXTERNAL PROBES GAMMA
Gamma BDKS-96B 57
Gamma and beta BDKS-96S 57
Gamma BDMG-96 57
EXTERNAL PROBES GAMMA
Gamma-search BDVG-96 58
Gamma-search BDPG-96 58
ContentsRadiation monitoring systemldquoPELIKANrdquo Radiation monitoring system (RMS) 6
BDMG-101 high range gamma area monitor 10
DBG-S11D wide range gamma area monitor 11
BDRG-52 high range gamma area monitor for accident and post-accident conditions 12
UDGP-01 Liquid technological environments monitor 13
UDMN-100 neutron area monitor 14
UDKG-100 Wel Liquid gamma monitor 14
BOP-1M data processing and transmission unit 15
UDA-1AB particulate monitor 16
UDG-1B noble gas monitor 17
UDG-03D noble gas monitor 18
UDI-1B iodine monitor 19
UDGB-01 noble gasesH-3C-14 monitor 20
UDGP-01 steam generator leakage monitor 21
UPPVM air flow parameters monitor 22
ldquoIMPULSrdquo external display unit 23
BI-2 remote display amp alarm unit 24
BASBAS-1s external alarm 25
SKGAV stack monitor 26
RMS software 28
RMS workstation ndash operator console 29
Configurator software 29
RM RACK radiation monitoring rack 30
SRKS-01D criticality accident alarm system 32
ldquoATLANT-Mrdquo environmental radiation monitoring system 34
ldquoBREEZErdquo high-volume air sampler 35
ldquoGAMMA-SENSORrdquo gamma-survey system 36
Radiation monitoring equipmentAREA MONITOR ldquoFREGATrdquo 38
BPI-1D local display unit 39
80
Gamma-search BDPG-96M 58
Gamma BDKG-96 stainless steel casing for geologic applications well logging 59
EXTERNAL PROBES NEUTRON
Neutron BDMN-96 59
Neutron-search BDKN-96 59
RZB-05D Hand-foot-clothing monitor 60
RZBA-04-04M whole body contamination monitor 61
RZA-05D alpha hand-monitor 62
UMF-2000 low level alpha- beta- counter 63
DRK dose area product meter 64
ldquoPROGRESS-BETArdquo scintillation beta spectrometer 65
ldquoPROGRESS-GAMMArdquo scintillation gamma spectrometer 66
ldquoPROGRESS-G(P)rdquo portable scintillation gamma spectrometer 67
ldquoPROGRESS-ARrdquo alpha radiometer 68
ldquoPROGRESSrdquo whole body counter 69
MKG-01D ldquoSADOVNIKrdquo spectrometry system 70
MKS-01A ldquoMULTIRAD-ASrdquo alpha spectrometer 71
UCRV-2 airflow monitor 72
PVP-06 portable air sampler 73
ldquoALPHARAD PLUSrdquo radon thoron amp their progeny monitor 74
UPG-P desktop gamma beam irradiator 75
UPGD-2M-D gamma beam irradiator 76
UKPN-2M-D neutron beam irradiator 77
SPC ldquoDozardquoRadiation monitoring equipment
68 69
Physical characteristicsDetectorbull Scintillation detector ZnS (Oslash 60 mm)
Samplebull Thin sample - diameter up to 70 mm bull Preparation technique - electro-depositionbull Thick sample - diameter 70 mm weight
200300 mg bull Preparation technique - application of powders
(prepared by radiochemical concentration by water evaporation or by pounding of mineral samples) onto a planchet with the help of spirit
Energy rangebull 15 divide 8 MeV
Minimum detectable activitybull Thin samples no more than 910-3 Bqsamplebull Thick samples no more than 180 Bqkg
Mechanical characteristicsOverall dimensions weightbull 195times120times210 mm 34 kg
Complete setBasic complete setbull Alpha radiometer ldquoProgress-ARrdquobull Check source (uranium isotopes)
Set of accessoriesbull Procedure manual for measurements of radi-
oactivity using scintillation alpha radiometer ldquoProgress-ARrdquo
bull ldquoProgressrdquo software
ldquoProgress-ARrdquo
bull Measurement of gross activity of alpha emitting radionuclides in thin samples
bull Measurement of gross activity of alpha emitting radionuclides in thick samples
bull Measurement of activity deposited on aerosol filters
ldquoPROGRESS-ARrdquoALPHA RADIOMETER
Several fixed positions of the detector enable to perform measurements in various geometries and to estimate the content ofbull Cs-137 in the whole bodybull I-131 in thyroidbull Co-60 Cs-137 Mn-54 Cr-51 in lungsbull Database for storage of measurement data and
resultsbull Uncertainty calculations based on measurement
databull Self tests using built-in LED
ldquoPROGRESSrdquo WHOLE BODY COUNTER
Physical characteristicsDetectorbull scintillation detector NaI (Tl) Oslash63times63 mm
Energy rangebull 02 divide 28 MeV
Minimum detectable activitybull By Cs-137 in the whole body - 1200 Bqbull By I-131 in thyroid - 100 Bqbull By Co-60 Cs-137 Mn-54 Cr-51 in lungs - 200 Bq
Mechanical characteristicsWeight bull No more than 120 kg
Complete setBasic complete setbull Collimator with rotator and holderbull Detector with incorporated ADCbull Patient chair and table for collimatorbull Check source Na-22bull Procedure manual for lifetime measurement of
gamma-emitting radionuclidesrsquo activity in human body using the gamma-spectrometer of human radiation ldquoProgressrdquo
bull laquoProgressraquo software
Optional equipment and servicebull Program of internal radiation committed internal
radiation effective dose calculation by the stand-ard model
bull Background phantombull Personal computer and printer
Collimator with rotator and holder
SPC ldquoDozardquoRadiation monitoring equipment
70 71
bull Categorization of wastes for the purpose of fur-ther processing including wastes with unknown radionuclide composition
bull Measurements during the incoming waste inspec-tion (accepting for storage disposal)
bull Certification of unconditioned and conditioned wastes in closed containers without opening them (at nuclear plants or at facilities providing collection storage transportation conditioning processing temporal storage and final disposal of radioactive waste)
bull Activity measurement of extended objects in situ without opening the equipment
bull Activity measurement of extended objects after opening (for example assessment of tubes used for oil transportation)
MKG-01D ldquoSADOVNIKrdquoSPECTROMETRY SYSTEM
Physical charachteristicsDetectorbull Detector unit GEM (GMX) with HPGe detector and
multi-positioning cryostat CFG-PMOD4-7 with 7 litre Dewar
bull Dose rate probe BDMG-200
Energy range bull With GEM detector 004 divide 30 MeVbull With GMX detector 0005 divide 15 MeVbull Dose rate probe BDMG-200 ndash 005 divide 30 MeV
Measurement rangebull 110-7 divide 10 Svhbull Relative efficiency of detection (in photopeak) at
13325 MeV (Co-60) 10 divide 150
Electrical characteristicsPower supplybull 220 V 50 Hz
Interfacebull USB
Complete setBasic complete setbull Spectrometric detector unit GEM (GMX) with
HPGe detector and multi-positioning cryostat with 7 litre Dewar
bull Portable digital multichannel analyzer DigiDARTbull Dose rate probe BDMG-200bull Autonomous power supply unit with built-in
batterybull Industrial computer keyboardbull Laser range-finderbull Thermographic printerbull Web-camerabull Device equipped with stepper motor for position-
ing of the spectrometric detectorbull Calibration device with reference sources
(Am-241 Co-60 Ba-133 Eu-152) for energy calibration
bull Removable collimators with end capbull Measurement proceduresbull ldquoClasterrdquo software
bull Measurement of gross alpha activity of alpha-emitting radionuclides
bull Measurement of alpha-emitting radionuclides activity in thin-layer samples meeting alpha-spectrometry requirements
Physical characteristicsDetectorbull Silicon ion-implanted 450 mm2
bull Easy to decontaminate thin windowbull dead layer less than 015 μmbull Background count rate in the range 3 divide 9 MeVbull No more than 09 h-1cm-2 for 450 mm2 detector
Energy rangebull 2 divide 9 MeVbull Lower limit of measurement range (minimum
detectable activity) 01 Bqbull Background count rate no more than 100 counts
in 24 hours
Electrical characteristics Power supplybull 220 V 50 Hz
Interfacebull USB
Complete setBasic complete setbull Detector unit with vacuum measuring chamber
and vacuum control systembull Low noise vacuum pump (type 2FY-05B or
equivalent)bull Check sourcebull ldquoProgressrdquo softwarebull Vacuum tube
MKS-01A ldquoMULTIRAD-ASrdquoALPHA SPECTROMETER
SPC ldquoDozardquoRadiation monitoring equipment
72 73
UCRV-2AIRFLOW MONITOR
bull Monitor of the air flow through filter of centralized multichannel sampling system
bull Radiation monitoring system (RMS) integration for internal exposures determination
bull Volume and flow rate measurements of the air that have passed through a analytical filter
bull Bar-code for filter identificationbull Operation as either standalone unit or as a part of
the RMS
Physical characteristicsMeasurement range of air volume bull 001 divide 9999 m3
Operation temperature range bull minus 20 divide +50 ordmС
Electrical characteristicsPower supply bull 220 V 50 Hz
Interface bull RS-485
PVP-06PORTABLE AIR SAMPLER
Air Sampler PVP-06 is indispensable for monitoring the radiation situation where the concentration of radioactive aerosols in the air does not require a sta-tionary sampling equipment Sampling head PVP-06 provides easy change of filters and cartridges
Purposebull To monitor the concentration of radioactive aero-
sols in the air sites
Controlled aerosolsbull Alpha- and beta-active aerosolsbull Daughter products of decay of radon and thoronbull Iodine isotopes
Physical characteristicsTypes of filtersbull Aerosol AFA-RSP-20bull Iodine AFA SI-20
Flow rate bull 33∙10-4 ndash 233∙10-4 m3s (20 divide 140 l min)
Electrical characteristicsPower supply bull 220 V50 Hzbull The vehicle power supply 108 divide 145 Vbull Internal battery
Minimal working time on internal battery to recharge bull 8 hours
Power consumption (at a flow rate of 100 lmin) bull 40 VA
Environment characteristicsOperating temperature bull minus 10 divide +40 deg C
Maximum humidity bull 90
Pressure bull 860 to 1060 hPA
Noise generated by the pump bull lt 55 dBA at 1 m
Mechanical characteristicsDimensions weight bull 241 times 108 times 160 mm 28 kg
Case material bull Plastic
Complete setbull Air sampler PVP-06bull AC power adapterbull Filters AFA-RSP-20 - 100 pcsbull Packaging for filters - 40 pcsbull Casebull Operation manualbull Calibration certificate
Optional equimpient bull Kit for sampling sorption columns of activated
carbon Ř head of sorption columns with protective
covers Ř activated charcoal SKT-3 - 1 pkg (02 L) Ř charocoal samples SC-13 - 8 pcs
bull Car charger bull Tipod bull Shoulder strapbull Calibration stand bull Filters AFA SI-20 - 100 pcs
Consumablesbull Aerosol filters AFA RSP-20bull Iodine filters AFA SI-20
SPC ldquoDozardquoRadiation monitoring equipment
74 75
Calibration of gamma dose and dose rate meters
Calibration ofbull Ambient equivalent dose H(10) meters (Sv Svh)bull Personal equivalent dose Hp(10) meters (Sv Svh)bull Exposure dose X meters (R Rh)bull Two sources in irradiator bull Select source and collimator opening using
tumbler
UPG-P DESKTOP GAMMA BEAM IRRADIATOR
Physical characteristicsRange of reproduced dose rate bull 05 μSvh divide 10 mSvh (50 μRh divide 100 mRh)
Sources activities bull 6times106 6times108 Bq (02 20 mCi) Cs-137
Overall dimensions bull 1250times400times300 mm
Irradiator weight bull Not more than 37 kg
Calibration bench weight bull Not more than 15 kg
Reference standards IEC 60846 IEC 61526
Physical characteristicsDetectorbull Silicon
Measurement range EEC measurement bull Measurement range of radon EEC
10 divide 10bull106 Bqbullm-3
bull Measurement range of thoron EEC 05 divide 10bull104 Bqbullm-3
bull Air flow through the filter 100plusmn05 lmin
Concentration measurementbull Measurement range of radon-222 concentration
in air 10 divide 20bull106 cpsbull Measurement range of 216Po(ThA)
1bull10-3 divide 1bull102 cpsbull Air sampler flow rate
10plusmn02 lminbull Measurement range of radon-222 concentration
in water samples 6 divide 800 Bqbullkg-1
bull Measurement range of radon-222 flux from soil surface 20 divide 103 mBqsbullm2
bull Measurement range of radon-222 concentration with preliminary sampling of air using air sam-plers 20 divide 107 Bqbullm-3
bull Measurement range of radon-222 concentration in samples of soil air 103 divide 106 Bqbullm-3
Operation temperature range bull 1 divide 35 ordmC
Electrical characteristicsPower supply bull 80 VA
Mechanical characteristicsOverall dimensions weight bull 220times200times165 mm 36 kg
ldquoALPHARAD PLUSrdquoRADON THORON amp THEIR PROGENY MONITORbull Measurement of radon and thoron concentration
and effective equivalent concentration (EEC)bull In the airbull In the indoor air of residential public and industri-
al buildings and structuresbull Measurement of radon in drinking water sourcesbull Measurements of radon flux from the soil surface
at land plots allocated for construction of houses public buildings and industrial facilities
bull Measurements of radon concentration in soil air
Reference standards IEC 61577
SPC ldquoDozardquoRadiation monitoring equipment
76 77
UKPN-2M-D NEUTRON BEAM IRRADIATOR
Reference standards IEC 61005 61322
Calibration of neutron dose and dose rate meters
Calibration ofbull Ambient equivalent dose H(10) meters (Sv Svh)bull Personal equivalent dose Hp(10) meters (Sv Svh)bull Flux density of neutrons (cm-2∙s-1)bull Transfer container for temporary storage of
sources bull Red light signal of source working position
Physical carachteristicsRange of reproduced dose ratebull 20 divide 800 μSvh
Range of reproduced flux densitiesbull 10 divide 400 cm-2∙s-1
Type of a source in use bull Pu-Be
Activity of a source in usebull 24х1011 Bq (with density of 107 s-1)
Overall dimensions weight no morebull 3000x750x2000 mm 300 kg
Required room dimensionsbull not less than 7x3x3 m
Electrical characteristicsPower supply bull 220 V 50 Hz
Calibration of gamma dose and dose rate meters
Calibration ofbull Ambient equivalent dose H(10) meters (Sv Svh)bull Personal equivalent dose Hp(10) meters (Sv Svh)bull Exposure dose X meters (R Rh)bull Four sources in irradiator bull Select source and move to working position
return to storage position using special rodbull Transfer container for temporary storage of
sources bull Red light signal of source working position
UPGD-2M-DGAMMA BEAM IRRADIATOR
Physical characteristicsRange of reproduced dose rate bull 05 μSvh divide 50 mSvh (50 μRh divide 5 Rh)
Maximum activity of source bull 2times1011 Bq (50 Ci) Cs-137
Overall dimensionsbull Irradiator 800times500times500 mmbull Guide rails length 30 mbull Height 16 mbull Weight not more than 700 kgbull Required room dimensions not less than 7x3x3 m
Electrical characteristicsPower supply bull 220 V 50 Hz
UPGD-2M-D
Reference standards IEC 60846 IEC 61526 IEC 61066
SPC ldquoDozardquo
78 79
Contents
MEASURING UNITS
DBG-S11D wide range gamma area monitor 40
UDKS-100 gamma and X-ray area monitor 41
UDMN-100 neutron area monitor 41
ALARM UNITS
BAS-2 ldquoMICROrdquo external visual alarm 42
BZS-2 ldquoMicrordquo external audible alarm 42
Illuminated warning signs 43
ldquoImpulsrdquo external display unit 43
UIM-3D area monitor count rate meter 44
DKG-05D personal gamma dosimeter 46
DVS-02D gamma-neutron personal electronic dosimeter 47
DVGI-8D new pen-type personal ionization chamber dosimeters 48
DKG-02U ldquoARBITERrdquo wide range gamma-dosimeter 49
DKG-07D ldquoDROZDrdquo gamma-dosimeter 50
MKS-15D ldquoSNEGIRrdquo multi ndash purpose radiation survey meter 51
SRPS-05D gamma monitor 52
DOZA-TLD multipurpose TLD system 53
DKS-96 universal radiation survey meter 54
EXTERNAL PROBES ALPHA
Alpha BDZA-96 55
Alpha BDZA-96B 55
Alpha BDZA-96M 55
Alpha BDZA-96S 55
Alpha BDZA-96T 55
EXTERNAL PROBES BETA
Beta BDZB-96 56
Beta BDZB-99 56
Beta BDZB-96B 56
Beta BDZB-96S 56
EXTERNAL PROBES GAMMA
Gamma BDKS-96B 57
Gamma and beta BDKS-96S 57
Gamma BDMG-96 57
EXTERNAL PROBES GAMMA
Gamma-search BDVG-96 58
Gamma-search BDPG-96 58
ContentsRadiation monitoring systemldquoPELIKANrdquo Radiation monitoring system (RMS) 6
BDMG-101 high range gamma area monitor 10
DBG-S11D wide range gamma area monitor 11
BDRG-52 high range gamma area monitor for accident and post-accident conditions 12
UDGP-01 Liquid technological environments monitor 13
UDMN-100 neutron area monitor 14
UDKG-100 Wel Liquid gamma monitor 14
BOP-1M data processing and transmission unit 15
UDA-1AB particulate monitor 16
UDG-1B noble gas monitor 17
UDG-03D noble gas monitor 18
UDI-1B iodine monitor 19
UDGB-01 noble gasesH-3C-14 monitor 20
UDGP-01 steam generator leakage monitor 21
UPPVM air flow parameters monitor 22
ldquoIMPULSrdquo external display unit 23
BI-2 remote display amp alarm unit 24
BASBAS-1s external alarm 25
SKGAV stack monitor 26
RMS software 28
RMS workstation ndash operator console 29
Configurator software 29
RM RACK radiation monitoring rack 30
SRKS-01D criticality accident alarm system 32
ldquoATLANT-Mrdquo environmental radiation monitoring system 34
ldquoBREEZErdquo high-volume air sampler 35
ldquoGAMMA-SENSORrdquo gamma-survey system 36
Radiation monitoring equipmentAREA MONITOR ldquoFREGATrdquo 38
BPI-1D local display unit 39
80
Gamma-search BDPG-96M 58
Gamma BDKG-96 stainless steel casing for geologic applications well logging 59
EXTERNAL PROBES NEUTRON
Neutron BDMN-96 59
Neutron-search BDKN-96 59
RZB-05D Hand-foot-clothing monitor 60
RZBA-04-04M whole body contamination monitor 61
RZA-05D alpha hand-monitor 62
UMF-2000 low level alpha- beta- counter 63
DRK dose area product meter 64
ldquoPROGRESS-BETArdquo scintillation beta spectrometer 65
ldquoPROGRESS-GAMMArdquo scintillation gamma spectrometer 66
ldquoPROGRESS-G(P)rdquo portable scintillation gamma spectrometer 67
ldquoPROGRESS-ARrdquo alpha radiometer 68
ldquoPROGRESSrdquo whole body counter 69
MKG-01D ldquoSADOVNIKrdquo spectrometry system 70
MKS-01A ldquoMULTIRAD-ASrdquo alpha spectrometer 71
UCRV-2 airflow monitor 72
PVP-06 portable air sampler 73
ldquoALPHARAD PLUSrdquo radon thoron amp their progeny monitor 74
UPG-P desktop gamma beam irradiator 75
UPGD-2M-D gamma beam irradiator 76
UKPN-2M-D neutron beam irradiator 77
SPC ldquoDozardquoRadiation monitoring equipment
70 71
bull Categorization of wastes for the purpose of fur-ther processing including wastes with unknown radionuclide composition
bull Measurements during the incoming waste inspec-tion (accepting for storage disposal)
bull Certification of unconditioned and conditioned wastes in closed containers without opening them (at nuclear plants or at facilities providing collection storage transportation conditioning processing temporal storage and final disposal of radioactive waste)
bull Activity measurement of extended objects in situ without opening the equipment
bull Activity measurement of extended objects after opening (for example assessment of tubes used for oil transportation)
MKG-01D ldquoSADOVNIKrdquoSPECTROMETRY SYSTEM
Physical charachteristicsDetectorbull Detector unit GEM (GMX) with HPGe detector and
multi-positioning cryostat CFG-PMOD4-7 with 7 litre Dewar
bull Dose rate probe BDMG-200
Energy range bull With GEM detector 004 divide 30 MeVbull With GMX detector 0005 divide 15 MeVbull Dose rate probe BDMG-200 ndash 005 divide 30 MeV
Measurement rangebull 110-7 divide 10 Svhbull Relative efficiency of detection (in photopeak) at
13325 MeV (Co-60) 10 divide 150
Electrical characteristicsPower supplybull 220 V 50 Hz
Interfacebull USB
Complete setBasic complete setbull Spectrometric detector unit GEM (GMX) with
HPGe detector and multi-positioning cryostat with 7 litre Dewar
bull Portable digital multichannel analyzer DigiDARTbull Dose rate probe BDMG-200bull Autonomous power supply unit with built-in
batterybull Industrial computer keyboardbull Laser range-finderbull Thermographic printerbull Web-camerabull Device equipped with stepper motor for position-
ing of the spectrometric detectorbull Calibration device with reference sources
(Am-241 Co-60 Ba-133 Eu-152) for energy calibration
bull Removable collimators with end capbull Measurement proceduresbull ldquoClasterrdquo software
bull Measurement of gross alpha activity of alpha-emitting radionuclides
bull Measurement of alpha-emitting radionuclides activity in thin-layer samples meeting alpha-spectrometry requirements
Physical characteristicsDetectorbull Silicon ion-implanted 450 mm2
bull Easy to decontaminate thin windowbull dead layer less than 015 μmbull Background count rate in the range 3 divide 9 MeVbull No more than 09 h-1cm-2 for 450 mm2 detector
Energy rangebull 2 divide 9 MeVbull Lower limit of measurement range (minimum
detectable activity) 01 Bqbull Background count rate no more than 100 counts
in 24 hours
Electrical characteristics Power supplybull 220 V 50 Hz
Interfacebull USB
Complete setBasic complete setbull Detector unit with vacuum measuring chamber
and vacuum control systembull Low noise vacuum pump (type 2FY-05B or
equivalent)bull Check sourcebull ldquoProgressrdquo softwarebull Vacuum tube
MKS-01A ldquoMULTIRAD-ASrdquoALPHA SPECTROMETER
SPC ldquoDozardquoRadiation monitoring equipment
72 73
UCRV-2AIRFLOW MONITOR
bull Monitor of the air flow through filter of centralized multichannel sampling system
bull Radiation monitoring system (RMS) integration for internal exposures determination
bull Volume and flow rate measurements of the air that have passed through a analytical filter
bull Bar-code for filter identificationbull Operation as either standalone unit or as a part of
the RMS
Physical characteristicsMeasurement range of air volume bull 001 divide 9999 m3
Operation temperature range bull minus 20 divide +50 ordmС
Electrical characteristicsPower supply bull 220 V 50 Hz
Interface bull RS-485
PVP-06PORTABLE AIR SAMPLER
Air Sampler PVP-06 is indispensable for monitoring the radiation situation where the concentration of radioactive aerosols in the air does not require a sta-tionary sampling equipment Sampling head PVP-06 provides easy change of filters and cartridges
Purposebull To monitor the concentration of radioactive aero-
sols in the air sites
Controlled aerosolsbull Alpha- and beta-active aerosolsbull Daughter products of decay of radon and thoronbull Iodine isotopes
Physical characteristicsTypes of filtersbull Aerosol AFA-RSP-20bull Iodine AFA SI-20
Flow rate bull 33∙10-4 ndash 233∙10-4 m3s (20 divide 140 l min)
Electrical characteristicsPower supply bull 220 V50 Hzbull The vehicle power supply 108 divide 145 Vbull Internal battery
Minimal working time on internal battery to recharge bull 8 hours
Power consumption (at a flow rate of 100 lmin) bull 40 VA
Environment characteristicsOperating temperature bull minus 10 divide +40 deg C
Maximum humidity bull 90
Pressure bull 860 to 1060 hPA
Noise generated by the pump bull lt 55 dBA at 1 m
Mechanical characteristicsDimensions weight bull 241 times 108 times 160 mm 28 kg
Case material bull Plastic
Complete setbull Air sampler PVP-06bull AC power adapterbull Filters AFA-RSP-20 - 100 pcsbull Packaging for filters - 40 pcsbull Casebull Operation manualbull Calibration certificate
Optional equimpient bull Kit for sampling sorption columns of activated
carbon Ř head of sorption columns with protective
covers Ř activated charcoal SKT-3 - 1 pkg (02 L) Ř charocoal samples SC-13 - 8 pcs
bull Car charger bull Tipod bull Shoulder strapbull Calibration stand bull Filters AFA SI-20 - 100 pcs
Consumablesbull Aerosol filters AFA RSP-20bull Iodine filters AFA SI-20
SPC ldquoDozardquoRadiation monitoring equipment
74 75
Calibration of gamma dose and dose rate meters
Calibration ofbull Ambient equivalent dose H(10) meters (Sv Svh)bull Personal equivalent dose Hp(10) meters (Sv Svh)bull Exposure dose X meters (R Rh)bull Two sources in irradiator bull Select source and collimator opening using
tumbler
UPG-P DESKTOP GAMMA BEAM IRRADIATOR
Physical characteristicsRange of reproduced dose rate bull 05 μSvh divide 10 mSvh (50 μRh divide 100 mRh)
Sources activities bull 6times106 6times108 Bq (02 20 mCi) Cs-137
Overall dimensions bull 1250times400times300 mm
Irradiator weight bull Not more than 37 kg
Calibration bench weight bull Not more than 15 kg
Reference standards IEC 60846 IEC 61526
Physical characteristicsDetectorbull Silicon
Measurement range EEC measurement bull Measurement range of radon EEC
10 divide 10bull106 Bqbullm-3
bull Measurement range of thoron EEC 05 divide 10bull104 Bqbullm-3
bull Air flow through the filter 100plusmn05 lmin
Concentration measurementbull Measurement range of radon-222 concentration
in air 10 divide 20bull106 cpsbull Measurement range of 216Po(ThA)
1bull10-3 divide 1bull102 cpsbull Air sampler flow rate
10plusmn02 lminbull Measurement range of radon-222 concentration
in water samples 6 divide 800 Bqbullkg-1
bull Measurement range of radon-222 flux from soil surface 20 divide 103 mBqsbullm2
bull Measurement range of radon-222 concentration with preliminary sampling of air using air sam-plers 20 divide 107 Bqbullm-3
bull Measurement range of radon-222 concentration in samples of soil air 103 divide 106 Bqbullm-3
Operation temperature range bull 1 divide 35 ordmC
Electrical characteristicsPower supply bull 80 VA
Mechanical characteristicsOverall dimensions weight bull 220times200times165 mm 36 kg
ldquoALPHARAD PLUSrdquoRADON THORON amp THEIR PROGENY MONITORbull Measurement of radon and thoron concentration
and effective equivalent concentration (EEC)bull In the airbull In the indoor air of residential public and industri-
al buildings and structuresbull Measurement of radon in drinking water sourcesbull Measurements of radon flux from the soil surface
at land plots allocated for construction of houses public buildings and industrial facilities
bull Measurements of radon concentration in soil air
Reference standards IEC 61577
SPC ldquoDozardquoRadiation monitoring equipment
76 77
UKPN-2M-D NEUTRON BEAM IRRADIATOR
Reference standards IEC 61005 61322
Calibration of neutron dose and dose rate meters
Calibration ofbull Ambient equivalent dose H(10) meters (Sv Svh)bull Personal equivalent dose Hp(10) meters (Sv Svh)bull Flux density of neutrons (cm-2∙s-1)bull Transfer container for temporary storage of
sources bull Red light signal of source working position
Physical carachteristicsRange of reproduced dose ratebull 20 divide 800 μSvh
Range of reproduced flux densitiesbull 10 divide 400 cm-2∙s-1
Type of a source in use bull Pu-Be
Activity of a source in usebull 24х1011 Bq (with density of 107 s-1)
Overall dimensions weight no morebull 3000x750x2000 mm 300 kg
Required room dimensionsbull not less than 7x3x3 m
Electrical characteristicsPower supply bull 220 V 50 Hz
Calibration of gamma dose and dose rate meters
Calibration ofbull Ambient equivalent dose H(10) meters (Sv Svh)bull Personal equivalent dose Hp(10) meters (Sv Svh)bull Exposure dose X meters (R Rh)bull Four sources in irradiator bull Select source and move to working position
return to storage position using special rodbull Transfer container for temporary storage of
sources bull Red light signal of source working position
UPGD-2M-DGAMMA BEAM IRRADIATOR
Physical characteristicsRange of reproduced dose rate bull 05 μSvh divide 50 mSvh (50 μRh divide 5 Rh)
Maximum activity of source bull 2times1011 Bq (50 Ci) Cs-137
Overall dimensionsbull Irradiator 800times500times500 mmbull Guide rails length 30 mbull Height 16 mbull Weight not more than 700 kgbull Required room dimensions not less than 7x3x3 m
Electrical characteristicsPower supply bull 220 V 50 Hz
UPGD-2M-D
Reference standards IEC 60846 IEC 61526 IEC 61066
SPC ldquoDozardquo
78 79
Contents
MEASURING UNITS
DBG-S11D wide range gamma area monitor 40
UDKS-100 gamma and X-ray area monitor 41
UDMN-100 neutron area monitor 41
ALARM UNITS
BAS-2 ldquoMICROrdquo external visual alarm 42
BZS-2 ldquoMicrordquo external audible alarm 42
Illuminated warning signs 43
ldquoImpulsrdquo external display unit 43
UIM-3D area monitor count rate meter 44
DKG-05D personal gamma dosimeter 46
DVS-02D gamma-neutron personal electronic dosimeter 47
DVGI-8D new pen-type personal ionization chamber dosimeters 48
DKG-02U ldquoARBITERrdquo wide range gamma-dosimeter 49
DKG-07D ldquoDROZDrdquo gamma-dosimeter 50
MKS-15D ldquoSNEGIRrdquo multi ndash purpose radiation survey meter 51
SRPS-05D gamma monitor 52
DOZA-TLD multipurpose TLD system 53
DKS-96 universal radiation survey meter 54
EXTERNAL PROBES ALPHA
Alpha BDZA-96 55
Alpha BDZA-96B 55
Alpha BDZA-96M 55
Alpha BDZA-96S 55
Alpha BDZA-96T 55
EXTERNAL PROBES BETA
Beta BDZB-96 56
Beta BDZB-99 56
Beta BDZB-96B 56
Beta BDZB-96S 56
EXTERNAL PROBES GAMMA
Gamma BDKS-96B 57
Gamma and beta BDKS-96S 57
Gamma BDMG-96 57
EXTERNAL PROBES GAMMA
Gamma-search BDVG-96 58
Gamma-search BDPG-96 58
ContentsRadiation monitoring systemldquoPELIKANrdquo Radiation monitoring system (RMS) 6
BDMG-101 high range gamma area monitor 10
DBG-S11D wide range gamma area monitor 11
BDRG-52 high range gamma area monitor for accident and post-accident conditions 12
UDGP-01 Liquid technological environments monitor 13
UDMN-100 neutron area monitor 14
UDKG-100 Wel Liquid gamma monitor 14
BOP-1M data processing and transmission unit 15
UDA-1AB particulate monitor 16
UDG-1B noble gas monitor 17
UDG-03D noble gas monitor 18
UDI-1B iodine monitor 19
UDGB-01 noble gasesH-3C-14 monitor 20
UDGP-01 steam generator leakage monitor 21
UPPVM air flow parameters monitor 22
ldquoIMPULSrdquo external display unit 23
BI-2 remote display amp alarm unit 24
BASBAS-1s external alarm 25
SKGAV stack monitor 26
RMS software 28
RMS workstation ndash operator console 29
Configurator software 29
RM RACK radiation monitoring rack 30
SRKS-01D criticality accident alarm system 32
ldquoATLANT-Mrdquo environmental radiation monitoring system 34
ldquoBREEZErdquo high-volume air sampler 35
ldquoGAMMA-SENSORrdquo gamma-survey system 36
Radiation monitoring equipmentAREA MONITOR ldquoFREGATrdquo 38
BPI-1D local display unit 39
80
Gamma-search BDPG-96M 58
Gamma BDKG-96 stainless steel casing for geologic applications well logging 59
EXTERNAL PROBES NEUTRON
Neutron BDMN-96 59
Neutron-search BDKN-96 59
RZB-05D Hand-foot-clothing monitor 60
RZBA-04-04M whole body contamination monitor 61
RZA-05D alpha hand-monitor 62
UMF-2000 low level alpha- beta- counter 63
DRK dose area product meter 64
ldquoPROGRESS-BETArdquo scintillation beta spectrometer 65
ldquoPROGRESS-GAMMArdquo scintillation gamma spectrometer 66
ldquoPROGRESS-G(P)rdquo portable scintillation gamma spectrometer 67
ldquoPROGRESS-ARrdquo alpha radiometer 68
ldquoPROGRESSrdquo whole body counter 69
MKG-01D ldquoSADOVNIKrdquo spectrometry system 70
MKS-01A ldquoMULTIRAD-ASrdquo alpha spectrometer 71
UCRV-2 airflow monitor 72
PVP-06 portable air sampler 73
ldquoALPHARAD PLUSrdquo radon thoron amp their progeny monitor 74
UPG-P desktop gamma beam irradiator 75
UPGD-2M-D gamma beam irradiator 76
UKPN-2M-D neutron beam irradiator 77
SPC ldquoDozardquoRadiation monitoring equipment
72 73
UCRV-2AIRFLOW MONITOR
bull Monitor of the air flow through filter of centralized multichannel sampling system
bull Radiation monitoring system (RMS) integration for internal exposures determination
bull Volume and flow rate measurements of the air that have passed through a analytical filter
bull Bar-code for filter identificationbull Operation as either standalone unit or as a part of
the RMS
Physical characteristicsMeasurement range of air volume bull 001 divide 9999 m3
Operation temperature range bull minus 20 divide +50 ordmС
Electrical characteristicsPower supply bull 220 V 50 Hz
Interface bull RS-485
PVP-06PORTABLE AIR SAMPLER
Air Sampler PVP-06 is indispensable for monitoring the radiation situation where the concentration of radioactive aerosols in the air does not require a sta-tionary sampling equipment Sampling head PVP-06 provides easy change of filters and cartridges
Purposebull To monitor the concentration of radioactive aero-
sols in the air sites
Controlled aerosolsbull Alpha- and beta-active aerosolsbull Daughter products of decay of radon and thoronbull Iodine isotopes
Physical characteristicsTypes of filtersbull Aerosol AFA-RSP-20bull Iodine AFA SI-20
Flow rate bull 33∙10-4 ndash 233∙10-4 m3s (20 divide 140 l min)
Electrical characteristicsPower supply bull 220 V50 Hzbull The vehicle power supply 108 divide 145 Vbull Internal battery
Minimal working time on internal battery to recharge bull 8 hours
Power consumption (at a flow rate of 100 lmin) bull 40 VA
Environment characteristicsOperating temperature bull minus 10 divide +40 deg C
Maximum humidity bull 90
Pressure bull 860 to 1060 hPA
Noise generated by the pump bull lt 55 dBA at 1 m
Mechanical characteristicsDimensions weight bull 241 times 108 times 160 mm 28 kg
Case material bull Plastic
Complete setbull Air sampler PVP-06bull AC power adapterbull Filters AFA-RSP-20 - 100 pcsbull Packaging for filters - 40 pcsbull Casebull Operation manualbull Calibration certificate
Optional equimpient bull Kit for sampling sorption columns of activated
carbon Ř head of sorption columns with protective
covers Ř activated charcoal SKT-3 - 1 pkg (02 L) Ř charocoal samples SC-13 - 8 pcs
bull Car charger bull Tipod bull Shoulder strapbull Calibration stand bull Filters AFA SI-20 - 100 pcs
Consumablesbull Aerosol filters AFA RSP-20bull Iodine filters AFA SI-20
SPC ldquoDozardquoRadiation monitoring equipment
74 75
Calibration of gamma dose and dose rate meters
Calibration ofbull Ambient equivalent dose H(10) meters (Sv Svh)bull Personal equivalent dose Hp(10) meters (Sv Svh)bull Exposure dose X meters (R Rh)bull Two sources in irradiator bull Select source and collimator opening using
tumbler
UPG-P DESKTOP GAMMA BEAM IRRADIATOR
Physical characteristicsRange of reproduced dose rate bull 05 μSvh divide 10 mSvh (50 μRh divide 100 mRh)
Sources activities bull 6times106 6times108 Bq (02 20 mCi) Cs-137
Overall dimensions bull 1250times400times300 mm
Irradiator weight bull Not more than 37 kg
Calibration bench weight bull Not more than 15 kg
Reference standards IEC 60846 IEC 61526
Physical characteristicsDetectorbull Silicon
Measurement range EEC measurement bull Measurement range of radon EEC
10 divide 10bull106 Bqbullm-3
bull Measurement range of thoron EEC 05 divide 10bull104 Bqbullm-3
bull Air flow through the filter 100plusmn05 lmin
Concentration measurementbull Measurement range of radon-222 concentration
in air 10 divide 20bull106 cpsbull Measurement range of 216Po(ThA)
1bull10-3 divide 1bull102 cpsbull Air sampler flow rate
10plusmn02 lminbull Measurement range of radon-222 concentration
in water samples 6 divide 800 Bqbullkg-1
bull Measurement range of radon-222 flux from soil surface 20 divide 103 mBqsbullm2
bull Measurement range of radon-222 concentration with preliminary sampling of air using air sam-plers 20 divide 107 Bqbullm-3
bull Measurement range of radon-222 concentration in samples of soil air 103 divide 106 Bqbullm-3
Operation temperature range bull 1 divide 35 ordmC
Electrical characteristicsPower supply bull 80 VA
Mechanical characteristicsOverall dimensions weight bull 220times200times165 mm 36 kg
ldquoALPHARAD PLUSrdquoRADON THORON amp THEIR PROGENY MONITORbull Measurement of radon and thoron concentration
and effective equivalent concentration (EEC)bull In the airbull In the indoor air of residential public and industri-
al buildings and structuresbull Measurement of radon in drinking water sourcesbull Measurements of radon flux from the soil surface
at land plots allocated for construction of houses public buildings and industrial facilities
bull Measurements of radon concentration in soil air
Reference standards IEC 61577
SPC ldquoDozardquoRadiation monitoring equipment
76 77
UKPN-2M-D NEUTRON BEAM IRRADIATOR
Reference standards IEC 61005 61322
Calibration of neutron dose and dose rate meters
Calibration ofbull Ambient equivalent dose H(10) meters (Sv Svh)bull Personal equivalent dose Hp(10) meters (Sv Svh)bull Flux density of neutrons (cm-2∙s-1)bull Transfer container for temporary storage of
sources bull Red light signal of source working position
Physical carachteristicsRange of reproduced dose ratebull 20 divide 800 μSvh
Range of reproduced flux densitiesbull 10 divide 400 cm-2∙s-1
Type of a source in use bull Pu-Be
Activity of a source in usebull 24х1011 Bq (with density of 107 s-1)
Overall dimensions weight no morebull 3000x750x2000 mm 300 kg
Required room dimensionsbull not less than 7x3x3 m
Electrical characteristicsPower supply bull 220 V 50 Hz
Calibration of gamma dose and dose rate meters
Calibration ofbull Ambient equivalent dose H(10) meters (Sv Svh)bull Personal equivalent dose Hp(10) meters (Sv Svh)bull Exposure dose X meters (R Rh)bull Four sources in irradiator bull Select source and move to working position
return to storage position using special rodbull Transfer container for temporary storage of
sources bull Red light signal of source working position
UPGD-2M-DGAMMA BEAM IRRADIATOR
Physical characteristicsRange of reproduced dose rate bull 05 μSvh divide 50 mSvh (50 μRh divide 5 Rh)
Maximum activity of source bull 2times1011 Bq (50 Ci) Cs-137
Overall dimensionsbull Irradiator 800times500times500 mmbull Guide rails length 30 mbull Height 16 mbull Weight not more than 700 kgbull Required room dimensions not less than 7x3x3 m
Electrical characteristicsPower supply bull 220 V 50 Hz
UPGD-2M-D
Reference standards IEC 60846 IEC 61526 IEC 61066
SPC ldquoDozardquo
78 79
Contents
MEASURING UNITS
DBG-S11D wide range gamma area monitor 40
UDKS-100 gamma and X-ray area monitor 41
UDMN-100 neutron area monitor 41
ALARM UNITS
BAS-2 ldquoMICROrdquo external visual alarm 42
BZS-2 ldquoMicrordquo external audible alarm 42
Illuminated warning signs 43
ldquoImpulsrdquo external display unit 43
UIM-3D area monitor count rate meter 44
DKG-05D personal gamma dosimeter 46
DVS-02D gamma-neutron personal electronic dosimeter 47
DVGI-8D new pen-type personal ionization chamber dosimeters 48
DKG-02U ldquoARBITERrdquo wide range gamma-dosimeter 49
DKG-07D ldquoDROZDrdquo gamma-dosimeter 50
MKS-15D ldquoSNEGIRrdquo multi ndash purpose radiation survey meter 51
SRPS-05D gamma monitor 52
DOZA-TLD multipurpose TLD system 53
DKS-96 universal radiation survey meter 54
EXTERNAL PROBES ALPHA
Alpha BDZA-96 55
Alpha BDZA-96B 55
Alpha BDZA-96M 55
Alpha BDZA-96S 55
Alpha BDZA-96T 55
EXTERNAL PROBES BETA
Beta BDZB-96 56
Beta BDZB-99 56
Beta BDZB-96B 56
Beta BDZB-96S 56
EXTERNAL PROBES GAMMA
Gamma BDKS-96B 57
Gamma and beta BDKS-96S 57
Gamma BDMG-96 57
EXTERNAL PROBES GAMMA
Gamma-search BDVG-96 58
Gamma-search BDPG-96 58
ContentsRadiation monitoring systemldquoPELIKANrdquo Radiation monitoring system (RMS) 6
BDMG-101 high range gamma area monitor 10
DBG-S11D wide range gamma area monitor 11
BDRG-52 high range gamma area monitor for accident and post-accident conditions 12
UDGP-01 Liquid technological environments monitor 13
UDMN-100 neutron area monitor 14
UDKG-100 Wel Liquid gamma monitor 14
BOP-1M data processing and transmission unit 15
UDA-1AB particulate monitor 16
UDG-1B noble gas monitor 17
UDG-03D noble gas monitor 18
UDI-1B iodine monitor 19
UDGB-01 noble gasesH-3C-14 monitor 20
UDGP-01 steam generator leakage monitor 21
UPPVM air flow parameters monitor 22
ldquoIMPULSrdquo external display unit 23
BI-2 remote display amp alarm unit 24
BASBAS-1s external alarm 25
SKGAV stack monitor 26
RMS software 28
RMS workstation ndash operator console 29
Configurator software 29
RM RACK radiation monitoring rack 30
SRKS-01D criticality accident alarm system 32
ldquoATLANT-Mrdquo environmental radiation monitoring system 34
ldquoBREEZErdquo high-volume air sampler 35
ldquoGAMMA-SENSORrdquo gamma-survey system 36
Radiation monitoring equipmentAREA MONITOR ldquoFREGATrdquo 38
BPI-1D local display unit 39
80
Gamma-search BDPG-96M 58
Gamma BDKG-96 stainless steel casing for geologic applications well logging 59
EXTERNAL PROBES NEUTRON
Neutron BDMN-96 59
Neutron-search BDKN-96 59
RZB-05D Hand-foot-clothing monitor 60
RZBA-04-04M whole body contamination monitor 61
RZA-05D alpha hand-monitor 62
UMF-2000 low level alpha- beta- counter 63
DRK dose area product meter 64
ldquoPROGRESS-BETArdquo scintillation beta spectrometer 65
ldquoPROGRESS-GAMMArdquo scintillation gamma spectrometer 66
ldquoPROGRESS-G(P)rdquo portable scintillation gamma spectrometer 67
ldquoPROGRESS-ARrdquo alpha radiometer 68
ldquoPROGRESSrdquo whole body counter 69
MKG-01D ldquoSADOVNIKrdquo spectrometry system 70
MKS-01A ldquoMULTIRAD-ASrdquo alpha spectrometer 71
UCRV-2 airflow monitor 72
PVP-06 portable air sampler 73
ldquoALPHARAD PLUSrdquo radon thoron amp their progeny monitor 74
UPG-P desktop gamma beam irradiator 75
UPGD-2M-D gamma beam irradiator 76
UKPN-2M-D neutron beam irradiator 77
SPC ldquoDozardquoRadiation monitoring equipment
74 75
Calibration of gamma dose and dose rate meters
Calibration ofbull Ambient equivalent dose H(10) meters (Sv Svh)bull Personal equivalent dose Hp(10) meters (Sv Svh)bull Exposure dose X meters (R Rh)bull Two sources in irradiator bull Select source and collimator opening using
tumbler
UPG-P DESKTOP GAMMA BEAM IRRADIATOR
Physical characteristicsRange of reproduced dose rate bull 05 μSvh divide 10 mSvh (50 μRh divide 100 mRh)
Sources activities bull 6times106 6times108 Bq (02 20 mCi) Cs-137
Overall dimensions bull 1250times400times300 mm
Irradiator weight bull Not more than 37 kg
Calibration bench weight bull Not more than 15 kg
Reference standards IEC 60846 IEC 61526
Physical characteristicsDetectorbull Silicon
Measurement range EEC measurement bull Measurement range of radon EEC
10 divide 10bull106 Bqbullm-3
bull Measurement range of thoron EEC 05 divide 10bull104 Bqbullm-3
bull Air flow through the filter 100plusmn05 lmin
Concentration measurementbull Measurement range of radon-222 concentration
in air 10 divide 20bull106 cpsbull Measurement range of 216Po(ThA)
1bull10-3 divide 1bull102 cpsbull Air sampler flow rate
10plusmn02 lminbull Measurement range of radon-222 concentration
in water samples 6 divide 800 Bqbullkg-1
bull Measurement range of radon-222 flux from soil surface 20 divide 103 mBqsbullm2
bull Measurement range of radon-222 concentration with preliminary sampling of air using air sam-plers 20 divide 107 Bqbullm-3
bull Measurement range of radon-222 concentration in samples of soil air 103 divide 106 Bqbullm-3
Operation temperature range bull 1 divide 35 ordmC
Electrical characteristicsPower supply bull 80 VA
Mechanical characteristicsOverall dimensions weight bull 220times200times165 mm 36 kg
ldquoALPHARAD PLUSrdquoRADON THORON amp THEIR PROGENY MONITORbull Measurement of radon and thoron concentration
and effective equivalent concentration (EEC)bull In the airbull In the indoor air of residential public and industri-
al buildings and structuresbull Measurement of radon in drinking water sourcesbull Measurements of radon flux from the soil surface
at land plots allocated for construction of houses public buildings and industrial facilities
bull Measurements of radon concentration in soil air
Reference standards IEC 61577
SPC ldquoDozardquoRadiation monitoring equipment
76 77
UKPN-2M-D NEUTRON BEAM IRRADIATOR
Reference standards IEC 61005 61322
Calibration of neutron dose and dose rate meters
Calibration ofbull Ambient equivalent dose H(10) meters (Sv Svh)bull Personal equivalent dose Hp(10) meters (Sv Svh)bull Flux density of neutrons (cm-2∙s-1)bull Transfer container for temporary storage of
sources bull Red light signal of source working position
Physical carachteristicsRange of reproduced dose ratebull 20 divide 800 μSvh
Range of reproduced flux densitiesbull 10 divide 400 cm-2∙s-1
Type of a source in use bull Pu-Be
Activity of a source in usebull 24х1011 Bq (with density of 107 s-1)
Overall dimensions weight no morebull 3000x750x2000 mm 300 kg
Required room dimensionsbull not less than 7x3x3 m
Electrical characteristicsPower supply bull 220 V 50 Hz
Calibration of gamma dose and dose rate meters
Calibration ofbull Ambient equivalent dose H(10) meters (Sv Svh)bull Personal equivalent dose Hp(10) meters (Sv Svh)bull Exposure dose X meters (R Rh)bull Four sources in irradiator bull Select source and move to working position
return to storage position using special rodbull Transfer container for temporary storage of
sources bull Red light signal of source working position
UPGD-2M-DGAMMA BEAM IRRADIATOR
Physical characteristicsRange of reproduced dose rate bull 05 μSvh divide 50 mSvh (50 μRh divide 5 Rh)
Maximum activity of source bull 2times1011 Bq (50 Ci) Cs-137
Overall dimensionsbull Irradiator 800times500times500 mmbull Guide rails length 30 mbull Height 16 mbull Weight not more than 700 kgbull Required room dimensions not less than 7x3x3 m
Electrical characteristicsPower supply bull 220 V 50 Hz
UPGD-2M-D
Reference standards IEC 60846 IEC 61526 IEC 61066
SPC ldquoDozardquo
78 79
Contents
MEASURING UNITS
DBG-S11D wide range gamma area monitor 40
UDKS-100 gamma and X-ray area monitor 41
UDMN-100 neutron area monitor 41
ALARM UNITS
BAS-2 ldquoMICROrdquo external visual alarm 42
BZS-2 ldquoMicrordquo external audible alarm 42
Illuminated warning signs 43
ldquoImpulsrdquo external display unit 43
UIM-3D area monitor count rate meter 44
DKG-05D personal gamma dosimeter 46
DVS-02D gamma-neutron personal electronic dosimeter 47
DVGI-8D new pen-type personal ionization chamber dosimeters 48
DKG-02U ldquoARBITERrdquo wide range gamma-dosimeter 49
DKG-07D ldquoDROZDrdquo gamma-dosimeter 50
MKS-15D ldquoSNEGIRrdquo multi ndash purpose radiation survey meter 51
SRPS-05D gamma monitor 52
DOZA-TLD multipurpose TLD system 53
DKS-96 universal radiation survey meter 54
EXTERNAL PROBES ALPHA
Alpha BDZA-96 55
Alpha BDZA-96B 55
Alpha BDZA-96M 55
Alpha BDZA-96S 55
Alpha BDZA-96T 55
EXTERNAL PROBES BETA
Beta BDZB-96 56
Beta BDZB-99 56
Beta BDZB-96B 56
Beta BDZB-96S 56
EXTERNAL PROBES GAMMA
Gamma BDKS-96B 57
Gamma and beta BDKS-96S 57
Gamma BDMG-96 57
EXTERNAL PROBES GAMMA
Gamma-search BDVG-96 58
Gamma-search BDPG-96 58
ContentsRadiation monitoring systemldquoPELIKANrdquo Radiation monitoring system (RMS) 6
BDMG-101 high range gamma area monitor 10
DBG-S11D wide range gamma area monitor 11
BDRG-52 high range gamma area monitor for accident and post-accident conditions 12
UDGP-01 Liquid technological environments monitor 13
UDMN-100 neutron area monitor 14
UDKG-100 Wel Liquid gamma monitor 14
BOP-1M data processing and transmission unit 15
UDA-1AB particulate monitor 16
UDG-1B noble gas monitor 17
UDG-03D noble gas monitor 18
UDI-1B iodine monitor 19
UDGB-01 noble gasesH-3C-14 monitor 20
UDGP-01 steam generator leakage monitor 21
UPPVM air flow parameters monitor 22
ldquoIMPULSrdquo external display unit 23
BI-2 remote display amp alarm unit 24
BASBAS-1s external alarm 25
SKGAV stack monitor 26
RMS software 28
RMS workstation ndash operator console 29
Configurator software 29
RM RACK radiation monitoring rack 30
SRKS-01D criticality accident alarm system 32
ldquoATLANT-Mrdquo environmental radiation monitoring system 34
ldquoBREEZErdquo high-volume air sampler 35
ldquoGAMMA-SENSORrdquo gamma-survey system 36
Radiation monitoring equipmentAREA MONITOR ldquoFREGATrdquo 38
BPI-1D local display unit 39
80
Gamma-search BDPG-96M 58
Gamma BDKG-96 stainless steel casing for geologic applications well logging 59
EXTERNAL PROBES NEUTRON
Neutron BDMN-96 59
Neutron-search BDKN-96 59
RZB-05D Hand-foot-clothing monitor 60
RZBA-04-04M whole body contamination monitor 61
RZA-05D alpha hand-monitor 62
UMF-2000 low level alpha- beta- counter 63
DRK dose area product meter 64
ldquoPROGRESS-BETArdquo scintillation beta spectrometer 65
ldquoPROGRESS-GAMMArdquo scintillation gamma spectrometer 66
ldquoPROGRESS-G(P)rdquo portable scintillation gamma spectrometer 67
ldquoPROGRESS-ARrdquo alpha radiometer 68
ldquoPROGRESSrdquo whole body counter 69
MKG-01D ldquoSADOVNIKrdquo spectrometry system 70
MKS-01A ldquoMULTIRAD-ASrdquo alpha spectrometer 71
UCRV-2 airflow monitor 72
PVP-06 portable air sampler 73
ldquoALPHARAD PLUSrdquo radon thoron amp their progeny monitor 74
UPG-P desktop gamma beam irradiator 75
UPGD-2M-D gamma beam irradiator 76
UKPN-2M-D neutron beam irradiator 77
SPC ldquoDozardquoRadiation monitoring equipment
76 77
UKPN-2M-D NEUTRON BEAM IRRADIATOR
Reference standards IEC 61005 61322
Calibration of neutron dose and dose rate meters
Calibration ofbull Ambient equivalent dose H(10) meters (Sv Svh)bull Personal equivalent dose Hp(10) meters (Sv Svh)bull Flux density of neutrons (cm-2∙s-1)bull Transfer container for temporary storage of
sources bull Red light signal of source working position
Physical carachteristicsRange of reproduced dose ratebull 20 divide 800 μSvh
Range of reproduced flux densitiesbull 10 divide 400 cm-2∙s-1
Type of a source in use bull Pu-Be
Activity of a source in usebull 24х1011 Bq (with density of 107 s-1)
Overall dimensions weight no morebull 3000x750x2000 mm 300 kg
Required room dimensionsbull not less than 7x3x3 m
Electrical characteristicsPower supply bull 220 V 50 Hz
Calibration of gamma dose and dose rate meters
Calibration ofbull Ambient equivalent dose H(10) meters (Sv Svh)bull Personal equivalent dose Hp(10) meters (Sv Svh)bull Exposure dose X meters (R Rh)bull Four sources in irradiator bull Select source and move to working position
return to storage position using special rodbull Transfer container for temporary storage of
sources bull Red light signal of source working position
UPGD-2M-DGAMMA BEAM IRRADIATOR
Physical characteristicsRange of reproduced dose rate bull 05 μSvh divide 50 mSvh (50 μRh divide 5 Rh)
Maximum activity of source bull 2times1011 Bq (50 Ci) Cs-137
Overall dimensionsbull Irradiator 800times500times500 mmbull Guide rails length 30 mbull Height 16 mbull Weight not more than 700 kgbull Required room dimensions not less than 7x3x3 m
Electrical characteristicsPower supply bull 220 V 50 Hz
UPGD-2M-D
Reference standards IEC 60846 IEC 61526 IEC 61066
SPC ldquoDozardquo
78 79
Contents
MEASURING UNITS
DBG-S11D wide range gamma area monitor 40
UDKS-100 gamma and X-ray area monitor 41
UDMN-100 neutron area monitor 41
ALARM UNITS
BAS-2 ldquoMICROrdquo external visual alarm 42
BZS-2 ldquoMicrordquo external audible alarm 42
Illuminated warning signs 43
ldquoImpulsrdquo external display unit 43
UIM-3D area monitor count rate meter 44
DKG-05D personal gamma dosimeter 46
DVS-02D gamma-neutron personal electronic dosimeter 47
DVGI-8D new pen-type personal ionization chamber dosimeters 48
DKG-02U ldquoARBITERrdquo wide range gamma-dosimeter 49
DKG-07D ldquoDROZDrdquo gamma-dosimeter 50
MKS-15D ldquoSNEGIRrdquo multi ndash purpose radiation survey meter 51
SRPS-05D gamma monitor 52
DOZA-TLD multipurpose TLD system 53
DKS-96 universal radiation survey meter 54
EXTERNAL PROBES ALPHA
Alpha BDZA-96 55
Alpha BDZA-96B 55
Alpha BDZA-96M 55
Alpha BDZA-96S 55
Alpha BDZA-96T 55
EXTERNAL PROBES BETA
Beta BDZB-96 56
Beta BDZB-99 56
Beta BDZB-96B 56
Beta BDZB-96S 56
EXTERNAL PROBES GAMMA
Gamma BDKS-96B 57
Gamma and beta BDKS-96S 57
Gamma BDMG-96 57
EXTERNAL PROBES GAMMA
Gamma-search BDVG-96 58
Gamma-search BDPG-96 58
ContentsRadiation monitoring systemldquoPELIKANrdquo Radiation monitoring system (RMS) 6
BDMG-101 high range gamma area monitor 10
DBG-S11D wide range gamma area monitor 11
BDRG-52 high range gamma area monitor for accident and post-accident conditions 12
UDGP-01 Liquid technological environments monitor 13
UDMN-100 neutron area monitor 14
UDKG-100 Wel Liquid gamma monitor 14
BOP-1M data processing and transmission unit 15
UDA-1AB particulate monitor 16
UDG-1B noble gas monitor 17
UDG-03D noble gas monitor 18
UDI-1B iodine monitor 19
UDGB-01 noble gasesH-3C-14 monitor 20
UDGP-01 steam generator leakage monitor 21
UPPVM air flow parameters monitor 22
ldquoIMPULSrdquo external display unit 23
BI-2 remote display amp alarm unit 24
BASBAS-1s external alarm 25
SKGAV stack monitor 26
RMS software 28
RMS workstation ndash operator console 29
Configurator software 29
RM RACK radiation monitoring rack 30
SRKS-01D criticality accident alarm system 32
ldquoATLANT-Mrdquo environmental radiation monitoring system 34
ldquoBREEZErdquo high-volume air sampler 35
ldquoGAMMA-SENSORrdquo gamma-survey system 36
Radiation monitoring equipmentAREA MONITOR ldquoFREGATrdquo 38
BPI-1D local display unit 39
80
Gamma-search BDPG-96M 58
Gamma BDKG-96 stainless steel casing for geologic applications well logging 59
EXTERNAL PROBES NEUTRON
Neutron BDMN-96 59
Neutron-search BDKN-96 59
RZB-05D Hand-foot-clothing monitor 60
RZBA-04-04M whole body contamination monitor 61
RZA-05D alpha hand-monitor 62
UMF-2000 low level alpha- beta- counter 63
DRK dose area product meter 64
ldquoPROGRESS-BETArdquo scintillation beta spectrometer 65
ldquoPROGRESS-GAMMArdquo scintillation gamma spectrometer 66
ldquoPROGRESS-G(P)rdquo portable scintillation gamma spectrometer 67
ldquoPROGRESS-ARrdquo alpha radiometer 68
ldquoPROGRESSrdquo whole body counter 69
MKG-01D ldquoSADOVNIKrdquo spectrometry system 70
MKS-01A ldquoMULTIRAD-ASrdquo alpha spectrometer 71
UCRV-2 airflow monitor 72
PVP-06 portable air sampler 73
ldquoALPHARAD PLUSrdquo radon thoron amp their progeny monitor 74
UPG-P desktop gamma beam irradiator 75
UPGD-2M-D gamma beam irradiator 76
UKPN-2M-D neutron beam irradiator 77
SPC ldquoDozardquo
78 79
Contents
MEASURING UNITS
DBG-S11D wide range gamma area monitor 40
UDKS-100 gamma and X-ray area monitor 41
UDMN-100 neutron area monitor 41
ALARM UNITS
BAS-2 ldquoMICROrdquo external visual alarm 42
BZS-2 ldquoMicrordquo external audible alarm 42
Illuminated warning signs 43
ldquoImpulsrdquo external display unit 43
UIM-3D area monitor count rate meter 44
DKG-05D personal gamma dosimeter 46
DVS-02D gamma-neutron personal electronic dosimeter 47
DVGI-8D new pen-type personal ionization chamber dosimeters 48
DKG-02U ldquoARBITERrdquo wide range gamma-dosimeter 49
DKG-07D ldquoDROZDrdquo gamma-dosimeter 50
MKS-15D ldquoSNEGIRrdquo multi ndash purpose radiation survey meter 51
SRPS-05D gamma monitor 52
DOZA-TLD multipurpose TLD system 53
DKS-96 universal radiation survey meter 54
EXTERNAL PROBES ALPHA
Alpha BDZA-96 55
Alpha BDZA-96B 55
Alpha BDZA-96M 55
Alpha BDZA-96S 55
Alpha BDZA-96T 55
EXTERNAL PROBES BETA
Beta BDZB-96 56
Beta BDZB-99 56
Beta BDZB-96B 56
Beta BDZB-96S 56
EXTERNAL PROBES GAMMA
Gamma BDKS-96B 57
Gamma and beta BDKS-96S 57
Gamma BDMG-96 57
EXTERNAL PROBES GAMMA
Gamma-search BDVG-96 58
Gamma-search BDPG-96 58
ContentsRadiation monitoring systemldquoPELIKANrdquo Radiation monitoring system (RMS) 6
BDMG-101 high range gamma area monitor 10
DBG-S11D wide range gamma area monitor 11
BDRG-52 high range gamma area monitor for accident and post-accident conditions 12
UDGP-01 Liquid technological environments monitor 13
UDMN-100 neutron area monitor 14
UDKG-100 Wel Liquid gamma monitor 14
BOP-1M data processing and transmission unit 15
UDA-1AB particulate monitor 16
UDG-1B noble gas monitor 17
UDG-03D noble gas monitor 18
UDI-1B iodine monitor 19
UDGB-01 noble gasesH-3C-14 monitor 20
UDGP-01 steam generator leakage monitor 21
UPPVM air flow parameters monitor 22
ldquoIMPULSrdquo external display unit 23
BI-2 remote display amp alarm unit 24
BASBAS-1s external alarm 25
SKGAV stack monitor 26
RMS software 28
RMS workstation ndash operator console 29
Configurator software 29
RM RACK radiation monitoring rack 30
SRKS-01D criticality accident alarm system 32
ldquoATLANT-Mrdquo environmental radiation monitoring system 34
ldquoBREEZErdquo high-volume air sampler 35
ldquoGAMMA-SENSORrdquo gamma-survey system 36
Radiation monitoring equipmentAREA MONITOR ldquoFREGATrdquo 38
BPI-1D local display unit 39
80
Gamma-search BDPG-96M 58
Gamma BDKG-96 stainless steel casing for geologic applications well logging 59
EXTERNAL PROBES NEUTRON
Neutron BDMN-96 59
Neutron-search BDKN-96 59
RZB-05D Hand-foot-clothing monitor 60
RZBA-04-04M whole body contamination monitor 61
RZA-05D alpha hand-monitor 62
UMF-2000 low level alpha- beta- counter 63
DRK dose area product meter 64
ldquoPROGRESS-BETArdquo scintillation beta spectrometer 65
ldquoPROGRESS-GAMMArdquo scintillation gamma spectrometer 66
ldquoPROGRESS-G(P)rdquo portable scintillation gamma spectrometer 67
ldquoPROGRESS-ARrdquo alpha radiometer 68
ldquoPROGRESSrdquo whole body counter 69
MKG-01D ldquoSADOVNIKrdquo spectrometry system 70
MKS-01A ldquoMULTIRAD-ASrdquo alpha spectrometer 71
UCRV-2 airflow monitor 72
PVP-06 portable air sampler 73
ldquoALPHARAD PLUSrdquo radon thoron amp their progeny monitor 74
UPG-P desktop gamma beam irradiator 75
UPGD-2M-D gamma beam irradiator 76
UKPN-2M-D neutron beam irradiator 77
80
Gamma-search BDPG-96M 58
Gamma BDKG-96 stainless steel casing for geologic applications well logging 59
EXTERNAL PROBES NEUTRON
Neutron BDMN-96 59
Neutron-search BDKN-96 59
RZB-05D Hand-foot-clothing monitor 60
RZBA-04-04M whole body contamination monitor 61
RZA-05D alpha hand-monitor 62
UMF-2000 low level alpha- beta- counter 63
DRK dose area product meter 64
ldquoPROGRESS-BETArdquo scintillation beta spectrometer 65
ldquoPROGRESS-GAMMArdquo scintillation gamma spectrometer 66
ldquoPROGRESS-G(P)rdquo portable scintillation gamma spectrometer 67
ldquoPROGRESS-ARrdquo alpha radiometer 68
ldquoPROGRESSrdquo whole body counter 69
MKG-01D ldquoSADOVNIKrdquo spectrometry system 70
MKS-01A ldquoMULTIRAD-ASrdquo alpha spectrometer 71
UCRV-2 airflow monitor 72
PVP-06 portable air sampler 73
ldquoALPHARAD PLUSrdquo radon thoron amp their progeny monitor 74
UPG-P desktop gamma beam irradiator 75
UPGD-2M-D gamma beam irradiator 76
UKPN-2M-D neutron beam irradiator 77