2
RedOne™ Rock Shield Pipe Coating Protection Keymay Industries • 53169 RR 225 • Sherwood Park, AB T8A 4T7 Office: 780-417-1955 Fax: 780-417-1104 www.keymay.com April 2015 Rev 0 Issued for Use Control # PDS-012 KEYMAYstandsproudly behind our productsand has completedover 1150 hours of material testing at ISO 17025accredited labs.Designed with the environment in mind, RedOne™passes all composition testingin accordance with the Environmental Protection Act. COST SAVINGS SUPERIOR CORROSION PROTECTION WORKER SAFETY RedOne Advantage FEATURES: RedOne rock shield provides long-term protection to pipeline coatings at risk of mechanical damage during backfill or while in service without shielding cathodic protection. RECOMMENDED USE: RedOne is installed over the finished coating on steel and plastic pipelines from sizes 2” to 56” NPS. Spiral Wrap: Wrap RedOne around pipe, keeping a recommended 4” overlap between seams. Sheets: Cut to match pipe circumference plus a recommended 4” overlapand secure with ties or tape. Parallel Installation: Unroll entire RedOne roll along the length of pipe so overlap meets at 6 o’clock and secure with ties or tape.

RedOne™ FEATURES: Rock Shield - KEYMAY Industries · RedOne Advantage FEATURES: RedOne rock shield provides long-term protection to pipeline coatings at risk of mechanical damage

  • Upload
    others

  • View
    8

  • Download
    0

Embed Size (px)

Citation preview

Page 1: RedOne™ FEATURES: Rock Shield - KEYMAY Industries · RedOne Advantage FEATURES: RedOne rock shield provides long-term protection to pipeline coatings at risk of mechanical damage

RedOne™Rock ShieldPipe Coating Protection

Keymay Industries • 53169 RR 225 • Sherwood Park, AB T8A 4T7Office: 780-417-1955 Fax: 780-417-1104

www.keymay.com

April 2015Rev 0 Issued for Use

Control # PDS-012

KEYMAYstandsproudly behind our productsand has completedover 1150 hours of material testing at ISO 17025accredited labs.Designed with the environment in mind, RedOne™passes all composition testingin accordance with the Environmental Protection Act.

COSTSAVINGS

SUPERIORCORROSION PROTECTION

WORKERSAFETY

RedOneAdvantage

FEATURES: RedOne rock shield provides long-term protection to pipeline coatings at risk of mechanical damage during backfill or while in service without shielding cathodic protection.

RECOMMENDED USE: RedOne is installed over the finished coating on steel and plastic pipelines from sizes 2” to 56” NPS.

Spiral Wrap: Wrap RedOne around pipe, keeping a recommended 4” overlap between seams.

Sheets: Cut to match pipe circumference plus a recommended 4” overlapand secure with ties or tape.

Parallel Installation: Unroll entire RedOne roll along the length of pipe so overlap meets at 6 o’clock and secure with ties or tape.

Page 2: RedOne™ FEATURES: Rock Shield - KEYMAY Industries · RedOne Advantage FEATURES: RedOne rock shield provides long-term protection to pipeline coatings at risk of mechanical damage

April 2015Rev 0 Issued for Use

Control # PDS-012

Keymay Industries • 53169 RR 225 • Sherwood Park, AB T8A 4T7Office: 780-417-1955 Fax: 780-417-1104

www.keymay.com

Available Sizes:

*Customsheet sizes available upon request

*Modified to cover intentional holiday with rock shield sample

Roll

Width

Roll

Length

Roll

Weight

Roll

Area

ft.

m

ft.

m

lbs.

kg

ft2

m2

2.0

0.61

30

9.1

55

25

60

5.6

3.0

0.91

30

9.1

80

36

90

8.3

4.0

1.2

34

10.4

120

55

136

12.9

6.0

1.8

34

10.4

182

83

204

18.9

24” x 30’ RedOne™Unit

36” x 30’ RedOne™

48” x 34’ RedOne™

72” x 34’ RedOne™

Impact Resistance(Falling Weight Test)

Impact Resistance (Limestone Drop Test @ Ambient conditions)

Impact Resistance (Limestone Drop Test @ -30 °C)

Cathodic Protection(CP) Shielding*

Heavy Metal Analysis by ICP-OES

IEC 62321-5:2013

Leachate Analysis

Tear Strength

ASTM G14-04 PASS (> 154 lbs.)

PASS

PASS

15.1 lbf/in

Non-shielding

Not Detected

Not Detected

ASTM G13/G13M-13

ASTM G13/G13M-13

CSA Z245.20-2014, Section 12.8

EPA: Ontario Regulation 347, Schedule 4, Revision 588

ASTM D624-00 (2012)

Presence of Cadmium, Lead, Mercury, Hexavalent Chromium

Impact Strength @ 48” drop height

10 drops (max) from 6 ft. with 35 lbs. limestone

10 drops (max) from 6 ft. with 35 lbs. limestone

Disbondment radius and hydrogen gas evolution

EPA: Ontario Regulation 347, Schedule 4, Revision 588

Tear strength average

Property Test Method Test Focus Typical Results