8
Wind power cables

Reka`s cables for wind power technology · NAHH-O-M Max. d.c.-resistance of the conductor at +20°C Ω/km Nominal diameter of the conductor mm Weight kg/km 3x150 0,206 36 1650 3x240

  • Upload
    others

  • View
    10

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Reka`s cables for wind power technology · NAHH-O-M Max. d.c.-resistance of the conductor at +20°C Ω/km Nominal diameter of the conductor mm Weight kg/km 3x150 0,206 36 1650 3x240

Wind power cables

Page 2: Reka`s cables for wind power technology · NAHH-O-M Max. d.c.-resistance of the conductor at +20°C Ω/km Nominal diameter of the conductor mm Weight kg/km 3x150 0,206 36 1650 3x240

2.

Wind power farms that are located in wide open areas are ideal for the production of clean renewable wind energy. Such places can be found inland close to fields and lakeareas, as well as close to the shoreline. On land the variable landscape with its hillsoffers more good sites for wind power generators.

Reka`s cables for wind power technology

Dryrex WIND products are 10, 20 and 36 kV medium voltage cables, suitable for the wind farm energy transfer network. They can be installed directly into the ground on the shoreline and on the terracing protruding out-wards from the shoreline. Dryrex WIND cables are suit-able for ground that is repeatedly or continuously wet.

For investments costs, the construction of a wind farm at a site onshore and inland is especially efficient when compared to sites planned further offshore or on islands. This is indicated by the clear majority of Nordic wind power projects. They can be executed reliably using Reka Cables’ Dryrex WIND and Rekoclean WIND power cables.

Reka Cables Ltd has years of experience in the feedcables mains installed inside wind mills. The halogen-free and flame-retardant 0.6/1 kV power cables in ourRekoclean WIND product range have been tested in practice and are cost efficient alternatives for compnents inside the wind power plants.

Page 3: Reka`s cables for wind power technology · NAHH-O-M Max. d.c.-resistance of the conductor at +20°C Ω/km Nominal diameter of the conductor mm Weight kg/km 3x150 0,206 36 1650 3x240

AHXAMK-W

3.

AHXAMK-W

Cenelec HD 620 S2:2010 Part 10 Section F

Cable typeAHXAMK-W

Nominaldiameter ofconductor

mm

Nominaldiameter of the

cablemm

Weightkg/km

3x70+35 9,5 65 26703x95+35 11,2 69 30503x120+35 12,6 73 34203x150+35 14,1 76 37803x185+35 15,8 80 42803x240+70 18,0 86 5440

Cable typeAHXAMK-W

Nominaldiameter ofconductor

mm

Nominaldiameter of the

cablemm

Weightkg/km

3x70+35 9,5 55 21503x95+35 11,2 59 25503x120+35 12,6 62 27103x150+35 14,1 66 31903x185+35 15,8 71 36403x240+35 18,0 76 43503x300+35 20,3 81 5030

Product examples Also available in other screen sizes.6/10 (12) kV

12/20 (24) kV

Conductor: Longitudinally watertight, round stranded and compacted aluminium conductor (EN 60228, class 2)Conductor screen: Extruded semiconducting polyethyleneInsulation: Extruded crosslinked polyethylene (XLPE)Insulation screen: Extruded semiconducting polyethyleneLongitudinal watertightness: Waterswellable material inside the conductor and semiconducting waterswelling tape over the insulation screen.Radial watertightness: Longitudinal aluminium laminated foil adhered to the inner surface of the sheath acts as a radial water barrier and the path for charging and earth fault currents.Sheath: Black weather resistant polyethylene (PE)Earthing conductor: Round stranded and compacted copper conductor (EN 60228, class 2)Assembly: Three sheathed phase conductors laid-up together with the earthing conductorApplications: For fixed installation outdoors and directly into the ground. The cable construction is both longitudinally and radially watertight and therefore suitable for very wet conditions. Not for submarine applications

Voltage levels: 6/10 (12) kV 12/20 (24) kV

Page 4: Reka`s cables for wind power technology · NAHH-O-M Max. d.c.-resistance of the conductor at +20°C Ω/km Nominal diameter of the conductor mm Weight kg/km 3x150 0,206 36 1650 3x240

AXLJ-F TT

AXLJ-F TT

4.

CENELEC HD 620 S2:2010 Part 10 Section M

Cable typeAXLJ-F TT

Nominaldiameter ofconductor

mm

Nominaldiameter of the

cablemm

Weightkg/km

3x50/16 8,1 54 18503x70/16 9,5 57 21003x95/16 11,2 61 25003x120/16 12,6 64 29003x150/25 14,1 68 33503x185/25 15,8 72 38003x240/25 18,0 77 4500

Cable typeAXLJ-F TT

Nominaldiameter ofconductor

mm

Nominaldiameter of the

cablemm

Weightkg/km

3x50/16 8,1 45 14003x70/16 9,5 48 16203x95/16 11,2 52 19503x120/16 12,6 55 23003x150/25 14,1 59 28003x185/25 15,8 63 32003x240/25 18,0 68 38003x300/25 20,3 73 4600

Product examples Also available in other screen sizes.6/10 (12) kV

12/20 (24) kV

Conductor: Longitudinally watertight, round stranded and compacted aluminium conductor (EN 60228, class 2)Conductor screen: Extruded semiconducting polyethyleneInsulation: Extruded crosslinked polyethylene (XLPE)Insulation screen: Extruded semiconducting polyethyleneLongitudinal watertightness: Three insulated watertight conductors laid-up together with water-swellable fillersMetallic screen: Layer of copper wires and a copper tape twisted around the phase conductorsRadial watertightness: Lapped aluminium laminated foil adhered to the inner surface of the sheathSheath: Black weather resistant polyethylene (PE)Applications: For fixed installation outdoors and directly into the ground. The cable construction is both longitudinally and radially watertight and therefore suitable for very wet conditions. Not for submarine applications.

Voltage levels: 6/10(12) kV 12/20(24) kV

Page 5: Reka`s cables for wind power technology · NAHH-O-M Max. d.c.-resistance of the conductor at +20°C Ω/km Nominal diameter of the conductor mm Weight kg/km 3x150 0,206 36 1650 3x240

Cable typeAXLJ-F TT

Nominaldiameter ofconductor

mm

Nominaldiameter of the

cablemm

Weightkg/km

1x95/16 11,2 39 12501x150/25 14,1 41 15001x240/25 18,0 46 19501x300/25 20,3 49 23001x400/35 23,0 52 26501x500/35 25,7 54 29501x630/35 29,4 58 34501x800/35 33,3 63 43001x1000/35 37,8 69 52001x1200/35 41,4 73 5750

Cable typeAXLJ-F TT

Nominaldiameter ofconductor

mm

Nominaldiameter of the

cable mm

Weightkg/km

1x50/16 8,1 30 6901x95/16 11,2 33 9401x150/25 14,1 36 11901x240/25 18,0 41 15801x300/25 20,3 43 18501x400/35 23,0 46 22401x500/35 25,7 49 25501x630/35 29,4 53 30801x800/35 33,3 57 40001x1000/35 37,8 63 46701x1200/35 41,4 68 5400

AXLJ-F TT

AXLJ-F TT

18/30 (36) kV

5.

CENELEC HD 620 S2:2010 Part 10 Section M

Product examples Also available in other screen sizes.6/10 (12) kV

Conductor: Longitudinally watertight, round stranded and compacted aluminium conductor (EN 60228, class 2)Conductor screen: Extruded semiconducting polyethyleneInsulation: Extruded crosslinked polyethylene (XLPE)Insulation screen: Extruded semiconducting polyethyleneLongitudinal watertightness: Waterswellable material inside the conductor and semiconducting waterswelling tape over the insulation screen.Metallic screen: Layer of copper wires and a copper tape twisted around the phase conductorRadial watertightness: Longitudinal aluminium laminated foil adhered to the inner surface of the sheathSheath: Black weather resistant black polyethylene (PE)Applications: For fixed installations outdoors and directly into the ground. The cable construction is both longitudinally and radially watertight and therefore suitable for very wet locations. Not for submarine applications.

Voltage levels: 12/20(24) kV 18/30(36) kV

Page 6: Reka`s cables for wind power technology · NAHH-O-M Max. d.c.-resistance of the conductor at +20°C Ω/km Nominal diameter of the conductor mm Weight kg/km 3x150 0,206 36 1650 3x240

Cable typeNAHH-O-M

Max. d.c.-resistance of the

conductor at +20°CΩ/km

Nominaldiameter of the

conductormm

Weightkg/km

3x150 0,206 36 16503x240 0,125 44 25503x300 0,100 51 3400

NAHH-O-M

NAHH-O-M

Product examples0,6/1 (1,2) kV

6.

CENELEC HD 604 S1:2005 Part 5 Section F

Conductor: Solid sector shaped aluminium conductors (EN 60228, class 1)Insulation: Extruded crosslinked polyethylene (XLPE)Assembly: Three sheathed phase conductors laid-up together with a polypropylene binder tapeSheath: Grey halogen-free polyolefin compoundApplication: For fixed installation indoors and outdoors. Especially for power transmission from the wind turbine machine room down to the transformer.

Voltage level: 0.6/1(1.2) kV

Page 7: Reka`s cables for wind power technology · NAHH-O-M Max. d.c.-resistance of the conductor at +20°C Ω/km Nominal diameter of the conductor mm Weight kg/km 3x150 0,206 36 1650 3x240

Cable typeHK

Max. d.c.-resistance of the

conductor at +20°CΩ/km

Nominaldiameter of the

conductor mm

Weightkg/km

16 1,15 5,0 14525 0,727 6,4 22535 0,524 7,5 31550 0,387 8,8 42570 0,268 11,0 61595 0,193 13,0 860

HK

HK

7.

EN 60228

Conductor: Round stranded copper conductor (EN 60228, class 2)Applications: As a earthing conductor and an electrode

Page 8: Reka`s cables for wind power technology · NAHH-O-M Max. d.c.-resistance of the conductor at +20°C Ω/km Nominal diameter of the conductor mm Weight kg/km 3x150 0,206 36 1650 3x240

Häm

een

Kirj

apai

no O

y 6/

2012

Reka Cables Ltd.Niinistönkatu 8–12P.O.Box 12, FI-05801 HyvinkääFinlandTel. +358 207 200 20Fax +358 207 200 300

Agantie 3FI-11319 RiihimäkiFinlandTel. +358 207 200 20Fax +358 200 300