M0.1 8X12 14X12 R R 18X12 18X12 20X12 DEPTH 20X12 WIDTH 18X12 HEIGHT WIDTH AD AD 12X12 CMD FD FD UC CMD AD AD 20X12 EX.18X12 EX.18X12 SYMBOL DESCRIPTION DUCTWORK LEGEND 18X12 HEIGHT WIDTH DEPTH WIDTH DUCTWORK, DOUBLE LINE & SINGLE LINE INSIDE "FREE AREA" DIMENSIONS ARE SHOWN DUCTWORK DOUBLE LINE & SINGLE LINE INSIDE "FREE AREA" DIMENSIONS SHOWN 5281' FLEXIBLE ROUND DUCT MAX. LENGTH = 5'-0" EXISTING DUCT TO REMAIN NOTATIONS & DIMENSIONS SAME AS NEW DUCT EXISTING DUCT, AIR DEVICES, EQUIPMENT, ETC. TO BE REMOVED. SUPPLY DUCTWORK SECTION INSIDE DIMENSIONS ARE SHOWN RETURN OR EXHAUST DUCTWORK SECTION OUTSIDE DIMENSIONS ARE SHOWN CLEAR DUCTWORK RISE (R) OR DROP (D) ARROW SHOWS DIRECTION OF AIR FLOW ELBOW TURNED UP WITH TURNING VANES ELBOW TURNED DOWN WITH TURNING VANES RADIUS TYPE ELBOW CENTERLINE RADIUS = 1.5 X WIDTH SQUARE TYPE ELBOW WITH DOUBLE THICKNESS VANES. VANES REQUIRED IN ALL DUCTWORK ELBOWS U.N.O. ACCESS DOOR (AD) 12X12 UNLESS NOTED OTHERWISE FIRE DAMPER (FD), FIRE DAMPER-3 HOUR RATED (FD(3HR)), FIRE DAMPER W/SIDEWALL GRILLE (FD(THINLINE) (RUSKIN IBD20G)). ALL FD'S, SHALL HAVE A 12X12 MINIMUM AD U.N.O. MANUAL VOLUME DAMPER (MD) MANUAL VOLUME DAMPER WITH CONCEALED DAMPER REGULATOR (CMD) (YOUNG'S REGULATOR- BOWDEN CABLE TYPE) AUTOMATIC MOTOR OPERATED DAMPER (AD) ALL AD SHALL HAVE A 12X12 ACCESS DOOR U.N.O. FLEXIBLE DUCTWORK CONNECTION ROUND RUNOUT TO DIFFUSER OR GRILLE WITH SQUARE-TO-ROUND TRANSITION. SEE DETAIL. "LOW PRESSURE SQUARE TO ROUND BRANCH DUCT CONNECTOR DETAIL". RUNOUT SIZE DETERMINED BY SIZE OF DIFFUSER U.N.O. 3/4" DOOR UNDERCUT - SEE ARCH. EQUAL AREA SPLITTER CONNECT TO EXISTING VERIFY EXACT SIZE & LOCATION AFM ACCESS DOOR AIR FLOW MONITOR - PROVIDE ACCESS DOOR UPSTREAM OF DEVICE. MARK TYPE AIR DEVICE LEGEND LEGEND RUNOUT REMARKS MFG / MODEL R = RETURN T = TRANSFER X = SQUARE NECK SIZE XY = RECTANGULAR NECK SIZE DAMPER & BLANKET X = SQUARE NECK SIZE FOR NECK SIZES 6X6 TO 9X9 * OBD - W/ ACCESSIBLE OPERATING PROVIDE SQUARE TO ROUND ADAPTOR. (1/2"X1/2"X1/2") EQUALIZING GRID Z = THROW, 4-WAY U.N.O. /FD = WITH CEILING RADIATION TITUS / 50F, ALUMINUM OMIT OBD ON T'S FOR NECK SIZES 6X6 TO 9X9 * BORDER NO.3 BORDER NO.6 MOUNTED CLG DIFFUSER * FOR NECK SIZES 12X12 & LARGER FACE TITUS / TDC FOR USE WITH CEILING XY = RECTANGULAR NECK SIZE DAMPER & BLANKET X = SQUARE NECK SIZE Z = THROW, 4-WAY U.N.O. /FD = WITH CEILING RADIATION U.N.O. 6X6 9X9 12X12 15X15 NECK SIZE RUNOUT PROVIDE EXTERNALLY INSULATED PROVIDE EXTERNALLY INSULATED SIDE TAP SUPPLY PLENUM. SIDE TAP SUPPLY PLENUM. OBD LOUVER FACE LAY-IN CEILING DIFFUSER AIR DEVICE SCHEDULE NOTES: CFM/FD SEE PLANS U.N.O. X = NUMBER OF 1" SLOTS 4'-0" LONG CFM/FD E = EXHAUST TITUS / TDC LD(XY)-(Z) CFM/FD SD(XY)-(Z) W/ BEVELED DROPPED TITUS / 50R, STEEL BORDER LOUVER FACE SURFACE TITUS / TBDI-30 INSULATED PLENUM PLASTER FRAME SEE PLANS LINEAR SLOT DIFFUSER 6X6 9X9 12X12 15X15 NECK SIZE ALUMINUM CUBE CORE REGISTER * FOR NECK SIZES 12X12 & LARGER LSD2(X) CFM EQUALIZING GRID E(X) PROVIDE SQUARE TO ROUND ADAPTOR. RUNOUT LEVER. (SEE NOTE 4 & 5 BELOW) BORDER AIR DEVICE SCHEDULE NOTES: 1. CFM = AIR FLOW (TYPICAL ALL AIR DEVICES). 2. COORDINATE BORDER/FRAME TYPE WITH ARCH REFLECTED CEILING PLAN. 3. DIRECTION ARROWS ON DRAWINGS SHOW FLOW PATTERN. 4. USE SUPPLY DIFFUSERS WITH O.B.D. IN DRYWALL OR INACCESSIBLE CEILINGS. 5. USE SUPPLY DIFFUSERS WITHOUT O.B.D. IN LAY-IN OR ACCESSIBLE CEILINGS. X = NUMBER OF 3/4" SLOTS 4'-0" LONG TITUS / TBDI-30 INSULATED PLENUM PLASTER FRAME SEE PLANS LINEAR SLOT DIFFUSER LSD1(X) CFM HORIZONTAL REAR BLADES SIDE WALL SUPPLY SEE PLANS XY = RECTANGULAR NECK SIZE GRILLE TITUS / 300RS SR(XY) CFM BLACK PATTERN CONTROLLERS BLACK PATTERN CONTROLLERS X = SQUARE NECK SIZE TITUS / 350RL +25,=217$/ %$56 $7 $7 OMIT OBD. CFM SEE PLANS WALL TRANSFER GRILLE WTG(XY) SURFACE MOUNTED XY = RECTANGULAR NECK SIZE 1/2" SPACING. X = SQUARE NECK SIZE TITUS / 350RL-SS +25,=217$/ %$56 $7 $7 CFM SEE PLANS RETURN GRILLE RG(XY) SURFACE MOUNTED XY = RECTANGULAR NECK SIZE 3/4" SPACING DRAWING NO. DRAWING TITLE REVISIONS PROJECT K P S Group, Inc. 2101 First Avenue North Birmingham, AL 35203 205.251.0125 205.458.1513 FAX ISSUE DATE PROJECT NUMBER PROJECT ADDRESS 147021-02 RELOCATION OF TIME INC. LIFESTYLE GROUP 2100 LAKESHORE DRIVE HOMEWOOD AL 35209 04/22/15 No. Description Date 3332 Old Montgomery Hwy Suite 103 Mark Harris Bldg Birmingham, AL. 35209 Phone: 205-870-0801 Fax: 205-870-0891 www.whitakerandrawson.com Whitaker & Rawson, LLC Mechanical: Direct Line: Plumbing: Direct Line: W&R PROJECT NUMBER: Mark D'Andrea (205) 949-5128 Erik Hartwig (205) 949-5107 14101 TEST AND BALANCE SCOPE OF WORK FIFTH FLOOR: ALL NEW AND EXISTING FANS, AIR TERMINAL UNITS, GRILLES, REGISTERS, AND DIFFUSERS. 1 1 1 1 1 ADDENDUM #02 5/1/2015 1

RELOCATION OF TIME INC. LIFESTYLErives.com/wp-content/uploads/2015/04/M0.1-LEGEND...INSULATED PLENUM TITUS / TBDI-30 PLASTER FRAME LINEAR SLOT SEE PLANS DIFFUSER 6X6 9X9 12X12 15X15

  • Upload
    others

  • View
    1

  • Download
    0

Embed Size (px)

Citation preview

Page 1: RELOCATION OF TIME INC. LIFESTYLErives.com/wp-content/uploads/2015/04/M0.1-LEGEND...INSULATED PLENUM TITUS / TBDI-30 PLASTER FRAME LINEAR SLOT SEE PLANS DIFFUSER 6X6 9X9 12X12 15X15

M0.1

8X1214X12

R R

18X12 18X12

20X12DEPTH

20X12

WIDTH

18X12HEIGHT

WIDTH

AD AD

12X12

CMD

FDFD

UC

CMD

ADAD

20X12

EX.18X12 EX.18X12

SYMBOL DESCRIPTION

DUCTWORK LEGEND

16"Ø16"Ø

18X12HEIGHT

WIDTH

DEPTHWIDTH

DUCTWORK, DOUBLE LINE & SINGLE LINEINSIDE "FREE AREA" DIMENSIONS ARE SHOWN

DUCTWORK DOUBLE LINE & SINGLE LINEINSIDE "FREE AREA" DIMENSIONS SHOWNØ = ROUND

FLEXIBLE ROUND DUCTMAX. LENGTH = 5'-0"

EXISTING DUCT TO REMAINNOTATIONS & DIMENSIONS SAMEAS NEW DUCT

EXISTING DUCT, AIR DEVICES, EQUIPMENT,ETC. TO BE REMOVED.

SUPPLY DUCTWORK SECTIONINSIDE DIMENSIONS ARE SHOWN

RETURN OR EXHAUST DUCTWORK SECTIONOUTSIDE DIMENSIONS ARE SHOWN CLEAR

DUCTWORK RISE (R) OR DROP (D)ARROW SHOWS DIRECTION OF AIR FLOW

ELBOW TURNED UP WITH TURNING VANES

ELBOW TURNED DOWN WITH TURNING VANES

RADIUS TYPE ELBOWCENTERLINE RADIUS = 1.5 X WIDTH

SQUARE TYPE ELBOW WITH DOUBLETHICKNESS VANES. VANES REQUIRED IN ALLDUCTWORK ELBOWS U.N.O.

ACCESS DOOR (AD)12X12 UNLESS NOTED OTHERWISE

FIRE DAMPER (FD), FIRE DAMPER-3 HOUR RATED(FD(3HR)), FIRE DAMPER W/SIDEWALL GRILLE(FD(THINLINE) (RUSKIN IBD20G)). ALL FD'S, SHALLHAVE A 12X12 MINIMUM AD U.N.O.

MANUAL VOLUME DAMPER (MD)

MANUAL VOLUME DAMPER WITH CONCEALEDDAMPER REGULATOR (CMD)(YOUNG'S REGULATOR- BOWDEN CABLE TYPE)

AUTOMATIC MOTOR OPERATED DAMPER (AD)ALL AD SHALL HAVE A 12X12 ACCESS DOORU.N.O.

FLEXIBLE DUCTWORK CONNECTION

ROUND RUNOUT TO DIFFUSER OR GRILLE WITHSQUARE-TO-ROUND TRANSITION. SEE DETAIL. "LOWPRESSURE SQUARE TO ROUND BRANCH DUCTCONNECTOR DETAIL". RUNOUT SIZE DETERMINED BYSIZE OF DIFFUSER U.N.O.

3/4" DOOR UNDERCUT - SEE ARCH.

EQUAL AREA SPLITTER

CONNECT TO EXISTINGVERIFY EXACT SIZE & LOCATION

AFM

ACCESS DOOR

AIR FLOW MONITOR - PROVIDEACCESS DOOR UPSTREAM OFDEVICE.

MARK TYPE

AIR DEVICE LEGENDLEGEND RUNOUT REMARKS MFG / MODEL

R = RETURNT = TRANSFERX = SQUARE NECK SIZE

XY = RECTANGULAR NECK SIZE

DAMPER & BLANKET

X = SQUARE NECK SIZE

FOR NECK SIZES 6X6 TO 9X9

*

OBD - W/ ACCESSIBLE OPERATING

PROVIDE SQUARE TO ROUND ADAPTOR.

(1/2"X1/2"X1/2")

EQUALIZING GRID

Z = THROW, 4-WAY U.N.O./FD = WITH CEILING RADIATION

TITUS / 50F, ALUMINUMOMIT OBD ON T'S

FOR NECK SIZES 6X6 TO 9X9

*

BORDER NO.3

BORDER NO.6MOUNTED CLG DIFFUSER

*

FOR NECK SIZES 12X12 & LARGER

FACE

12"Ø

TITUS / TDC

FOR USE WITH CEILING

XY = RECTANGULAR NECK SIZE

DAMPER & BLANKET

X = SQUARE NECK SIZE

Z = THROW, 4-WAY U.N.O./FD = WITH CEILING RADIATION

12"Ø

U.N.O.6X69X912X1215X15

6"Ø8"Ø10"Ø

NECK SIZE RUNOUT

PROVIDE EXTERNALLY INSULATED

PROVIDE EXTERNALLY INSULATEDSIDE TAP SUPPLY PLENUM.

SIDE TAP SUPPLY PLENUM.

OBD

LOUVER FACE LAY-INCEILING DIFFUSER

AIR DEVICE SCHEDULE NOTES:

CFM/FD

SEE PLANS

U.N.O.

X = NUMBER OF 1" SLOTS4'-0" LONG

CFM/FD

E = EXHAUST

TITUS / TDC

LD(XY)-(Z)CFM/FD

SD(XY)-(Z)

W/ BEVELED DROPPED

TITUS / 50R, STEEL BORDER

LOUVER FACE SURFACE

TITUS / TBDI-30INSULATED PLENUMPLASTER FRAME

SEE PLANSLINEAR SLOTDIFFUSER

6X69X912X1215X15

6"Ø8"Ø10"Ø

NECK SIZE

ALUMINUM CUBECORE REGISTER

*

FOR NECK SIZES 12X12 & LARGER

LSD2(X)CFM

EQUALIZING GRID

E(X)

PROVIDE SQUARE TO ROUND ADAPTOR.

RUNOUT

LEVER. (SEE NOTE 4 & 5 BELOW)

BORDER

AIR DEVICE SCHEDULE NOTES:

1. CFM = AIR FLOW (TYPICAL ALL AIR DEVICES).

2. COORDINATE BORDER/FRAME TYPE WITH ARCH REFLECTED CEILING PLAN.

3. DIRECTION ARROWS ON DRAWINGS SHOW FLOW PATTERN.

4. USE SUPPLY DIFFUSERS WITH O.B.D. IN DRYWALL OR INACCESSIBLE CEILINGS.

5. USE SUPPLY DIFFUSERS WITHOUT O.B.D. IN LAY-IN OR ACCESSIBLE CEILINGS.

X = NUMBER OF 3/4" SLOTS4'-0" LONG

TITUS / TBDI-30INSULATED PLENUMPLASTER FRAME

SEE PLANSLINEAR SLOTDIFFUSERLSD1(X)

CFM

HORIZONTAL REAR BLADESSIDE WALL SUPPLY SEE PLANSXY = RECTANGULAR NECK SIZEGRILLE

TITUS / 300RSSR(XY)CFM

BLACK PATTERN CONTROLLERS

BLACK PATTERN CONTROLLERS

X = SQUARE NECK SIZE TITUS / 350RLHORIZONTAL BARS AT 35° ATOMIT OBD.

CFMSEE PLANSWALL TRANSFER

GRILLEWTG(XY)

SURFACE MOUNTEDXY = RECTANGULAR NECK SIZE 1/2" SPACING.

X = SQUARE NECK SIZE TITUS / 350RL-SSHORIZONTAL BARS AT 45° ATCFM

SEE PLANSRETURN GRILLERG(XY)SURFACE MOUNTEDXY = RECTANGULAR NECK SIZE 3/4" SPACING

DRAWING NO.

DRAWING TITLE

REVISIONS

PROJECT

K P S Group, Inc.

2101 First Avenue North

Birmingham, AL 35203

205.251.0125

205.458.1513 FAX

ISSUE DATE

PROJECT NUMBER

PROJECT ADDRESS

147021-02

RELOCATION

OF TIME INC.

LIFESTYLE

GROUP

2100 LAKESHORE DRIVE

HOMEWOOD AL 35209

04/22/15

No. Description Date

3332 Old Montgomery HwySuite 103 Mark Harris BldgBirmingham, AL. 35209

Phone: 205-870-0801Fax: 205-870-0891

www.whitakerandrawson.com

Whitaker & Rawson, LLC

Mechanical: Direct Line:Plumbing: Direct Line:

W&R PROJECT NUMBER:

Mark D'Andrea(205) 949-5128

Erik Hartwig(205) 949-5107

14101

TEST AND BALANCE SCOPE OF WORK

FIFTH FLOOR: ALL NEW ANDEXISTING FANS, AIR TERMINAL UNITS,GRILLES, REGISTERS, AND DIFFUSERS.

1

1

1

1

1 ADDENDUM #02 5/1/2015

1