Note: This test report is prepared for the customer shown above and for the device described herein. It may not be duplicated or used in part without prior written consent from Bay Area Compliance Laboratories Corp. (Dongguan). ETSI EN 301 489-1 V2.2.0 (2017-03) ETSI EN 301 489-3 V2.1.1 (2017-03) TEST REPORT For United GULF GATE Co. Aladel Tower,F21,Fahad Al Salem St., State of KUWAIT Model: XT-10P Report Type: Amended Report Product Type: IP Video Intercom Report Number: RXM180306052-02A1 Report Date: 2018-05-11 Reviewed By: Jerry Zhang EMC Manager Test Laboratory: Bay Area Compliance Laboratories Corp. (Dongguan) No.69 Pulongcun, Puxinhu Industry Area, Tangxia, Dongguan, Guangdong, China Tel: +86-769-86858888 Fax: +86-769-86858891 www.baclcorp.com.cn

RXM180306052-02A1 ETSI EN 301 489-1 &3 EMC Report€¦ · Note: This test report is prepared for the customer shown above and for the device described herein. It may not be duplicated

  • Upload
    others

  • View
    6

  • Download
    0

Embed Size (px)

Citation preview

Page 1: RXM180306052-02A1 ETSI EN 301 489-1 &3 EMC Report€¦ · Note: This test report is prepared for the customer shown above and for the device described herein. It may not be duplicated

Note: This test report is prepared for the customer shown above and for the device described herein. It may not be duplicated or used in part without prior written consent from Bay Area Compliance Laboratories Corp. (Dongguan).

ETSI EN 301 489-1 V2.2.0 (2017-03) ETSI EN 301 489-3 V2.1.1 (2017-03)

TEST REPORT For

United GULF GATE Co.

Aladel Tower,F21,Fahad Al Salem St., State of KUWAIT

Model: XT-10P

Report Type:

Amended Report

Product Type:

IP Video Intercom

Report Number: RXM180306052-02A1

Report Date: 2018-05-11

Reviewed By: Jerry Zhang EMC Manager

Test Laboratory:

Bay Area Compliance Laboratories Corp. (Dongguan) No.69 Pulongcun, Puxinhu Industry Area, Tangxia, Dongguan, Guangdong, China Tel: +86-769-86858888 Fax: +86-769-86858891 www.baclcorp.com.cn

Page 2: RXM180306052-02A1 ETSI EN 301 489-1 &3 EMC Report€¦ · Note: This test report is prepared for the customer shown above and for the device described herein. It may not be duplicated

Bay Area Compliance Laboratories Corp. (Dongguan) Report No.: RXM180306052-02A1

ETSI EN 301 489-1 &3 Page 2 of 36

TABLE OF CONTENTS DOCUMENT REVISION HISTORY ......................................................................................................................... 3 

GENERAL INFORMATION ...................................................................................................................................... 4 PRODUCT DESCRIPTION FOR EQUIPMENT UNDER TEST (EUT) ................................................................... 4 OBJECTIVE ............................................................................................................................................................... 4 TEST METHODOLOGY ........................................................................................................................................... 4 

SYSTEM TEST CONFIGURATION ......................................................................................................................... 5 DESCRIPTION OF TEST CONFIGURATION ......................................................................................................... 5 EQUIPMENT MODIFICATIONS ............................................................................................................................. 5 EUT EXERCISE SOFTWARE .................................................................................................................................. 5 BLOCK DIAGRAM OF TEST SETUP ...................................................................................................................... 5 SUPPORT EQUIPMENT LIST AND DETAILS ....................................................................................................... 7 SUPPORT CABLE LIST AND DETAILS ................................................................................................................. 7 TEST EQUIPMENT LIST .......................................................................................................................................... 8 ENVIRONMENTAL CONDITIONS ......................................................................................................................... 8 

SUMMARY OF TEST RESULTS .............................................................................................................................. 9 

1 – ENCLOSURE OF ANCILLARY EQUIPMENT MEASURED ON A STAND ALONE BASIS .................. 10 MEASUREMENT UNCERTAINTY ....................................................................................................................... 10 TEST SYSTEM SETUP ........................................................................................................................................... 10 EMI TEST RECEIVER SETUP ............................................................................................................................... 11 TEST PROCEDURE ................................................................................................................................................ 12 CORRECTED AMPLITUDE & MARGIN CALCULATION ................................................................................. 12 TEST DATA ............................................................................................................................................................. 13 

7 – RADIO FREQUENCY ELECTROMAGNETIC FIELDS (80 MHZ TO 6 000 MHZ) .................................. 21 TEST SYSTEM SETUP ........................................................................................................................................... 21 TEST LEVEL ........................................................................................................................................................... 21 PERFORMANCE CRITERION: A .......................................................................................................................... 21 TEST PROCEDURE ................................................................................................................................................ 21 TEST DATA ............................................................................................................................................................. 22 

8 – ELECTROSTATIC DISCHARGES ................................................................................................................... 24 TEST SYSTEM SETUP ........................................................................................................................................... 24 TEST LEVEL ........................................................................................................................................................... 24 PERFORMANCE CRITERION: B .......................................................................................................................... 24 TEST PROCEDURE ................................................................................................................................................ 25 TEST DATA ............................................................................................................................................................. 26 

EXHIBIT A – EUT PHOTOGRAPHS...................................................................................................................... 29 

EXHIBIT B – TEST SETUP PHOTOGRAPHS ...................................................................................................... 32 

BELOW IS THE ORIGINAL REPORT .................................................................................................................. 36 

Page 3: RXM180306052-02A1 ETSI EN 301 489-1 &3 EMC Report€¦ · Note: This test report is prepared for the customer shown above and for the device described herein. It may not be duplicated

Bay Area Compliance Laboratories Corp. (Dongguan) Report No.: RXM180306052-02A1

ETSI EN 301 489-1 &3 Page 3 of 36

DOCUMENT REVISION HISTORY

Note: This is the amended report application basing on the original report. The differences between them as following: 1) Changed the applicant to : United GULF GATE Co. (Address: Aladel Tower,F21,Fahad Al Salem St., State

of KUWAIT). 2) Changed the product name to: IP Video Intercom. 3) Changed the model name to: XT-10P. 4) Changed the trade name to: Xontel. 5) For the appearance, changed the silk-screen of trade name and the label. The changes between the original device and the current one are stated and guaranteed by the applicant, the

differences between them will affect the test results. We will update the related test results, test photos and

EUT photos.

Revision Number Report Number Description of Revision Date of Revision

0 RXM180205051-02 Original Report 2018-03-14

1 RXM180306052-02A1 Amended Report 2018-05-11

Page 4: RXM180306052-02A1 ETSI EN 301 489-1 &3 EMC Report€¦ · Note: This test report is prepared for the customer shown above and for the device described herein. It may not be duplicated

Bay Area Compliance Laboratories Corp. (Dongguan) Report No.: RXM180306052-02A1

ETSI EN 301 489-1 &3 Page 4 of 36

GENERAL INFORMATION Product Description for Equipment under Test (EUT)

EUT Name: IP Video Intercom EUT Model: XT-10P

Rated Input Voltage: DC 12V or PoE External Dimension: 102mm (L)*161.5mm (W)*38mm (H)

Serial Number: 180306052 EUT Received Date: 2018.04.27

Objective This report is prepared on behalf of United GULF GATE Co. in accordance with ETSI EN 301 489-1 V2.2.0 (2017-03) ElectroMagnetic Compatibility (EMC) standard for radio equipment and services; Part 1: Common technical requirements; Harmonised Standard covering the essential requirements of article 3.1(b) of Directive 2014/53/EU and the essential requirements of article 6 of Directive 2014/30/EU; ETSI EN 301 489-3 V2.1.1 (2017-03) ElectroMagnetic Compatibility (EMC) standard for radio equipment and services; Part 3: Specific conditions for Short-Range Devices (SRD) operating on frequencies between 9 kHz and 246 GHz. The objective is to determine the compliance of EUT with: ETSI EN 301 489-1 V2.2.0 (2017-03) ETSI EN 301 489-3 V2.1.1 (2017-03) Test Methodology All measurements contained in this report were conducted with ETSI EN 301 489-1 V2.2.0 (2017-03) ElectroMagnetic Compatibility (EMC) standard for radio equipment and services; Part 1: Common technical requirements; Harmonised Standard covering the essential requirements of article 3.1(b) of Directive 2014/53/EU and the essential requirements of article 6 of Directive 2014/30/EU.

Page 5: RXM180306052-02A1 ETSI EN 301 489-1 &3 EMC Report€¦ · Note: This test report is prepared for the customer shown above and for the device described herein. It may not be duplicated

Bay Area Compliance Laboratories Corp. (Dongguan) Report No.: RXM180306052-02A1

ETSI EN 301 489-1 &3 Page 5 of 36

SYSTEM TEST CONFIGURATION Description of Test Configuration

Test Mode M1 Adapter supply & talking M2 PoE supply & talking

Equipment Modifications No modification was made to the EUT. EUT Exercise Software No EUT software for testing. Block Diagram of Test Setup M1:

1.0M

eter

Page 6: RXM180306052-02A1 ETSI EN 301 489-1 &3 EMC Report€¦ · Note: This test report is prepared for the customer shown above and for the device described herein. It may not be duplicated

Bay Area Compliance Laboratories Corp. (Dongguan) Report No.: RXM180306052-02A1

ETSI EN 301 489-1 &3 Page 6 of 36

M2:

1.0M

eter

Page 7: RXM180306052-02A1 ETSI EN 301 489-1 &3 EMC Report€¦ · Note: This test report is prepared for the customer shown above and for the device described herein. It may not be duplicated

Bay Area Compliance Laboratories Corp. (Dongguan) Report No.: RXM180306052-02A1

ETSI EN 301 489-1 &3 Page 7 of 36

Support Equipment List and Details

Support Cable List and Details

Cable Description Shielding

Type Ferrite Core Length (m)

From To

RJ45 Cable No No 5 RJ45 Port of EUT Door Phone

Signal Cable No No 5 Door Port of EUT Switch Button

Signal Cable No No 5 RS485 Port of EUT Exchanger

Signal Cable No No 5 Relay Port of EUT Relay

Power Cable No No 1.4 Power Port of EUT Adapter

RJ45 Cable No No 1 RJ45 Port of EUT PoE

RJ45 Cable No No 5 RJ45 Port of PoE Door Phone

Manufacturer Description Model Serial Number

TOTOLINK PoE G0545-480-050-POE100 N/A TP-LINK Exchanger TL-SF1008P 114A297001782 Schneider Relay RXM2LB2BD N/A AKUVOX Door Phone C313 N/A

Gouldin Switch Button N/A N/A CWT Adapter 2ABB018F N/A

Page 8: RXM180306052-02A1 ETSI EN 301 489-1 &3 EMC Report€¦ · Note: This test report is prepared for the customer shown above and for the device described herein. It may not be duplicated

Bay Area Compliance Laboratories Corp. (Dongguan) Report No.: RXM180306052-02A1

ETSI EN 301 489-1 &3 Page 8 of 36

Test Equipment List

Manufacturer Description Model Serial Number Calibration Date

Calibration Due Date

Sunol Sciences Antenna JB3 A060611-1 2017-11-10 2020-11-10R&S EMI Test Receiver ESCI 100224 2017-12-11 2018-12-11HP Amplifier 8447D 2727A05902 2017-09-05 2018-09-05N/A Coaxial Cable C-NJNJ-50 C-0400-01 2017-09-05 2018-09-05N/A Coaxial Cable C-NJNJ-50 C-0075-01 2017-09-05 2018-09-05N/A Coaxial Cable C-NJNJ-50 C-1000-01 2017-09-05 2018-09-05

ETS-Lindgren Horn Antenna 3115 000 527 35 2016-01-05 2019-01-04Agilent Spectrum Analyzer E4440A SG43360054 2018-01-04 2019-01-04

N/A Coaxial Cable C-SJSJ-50 C-0800-01 2017-09-05 2018-09-05MITEQ Amplifier AFS42-00101800-25-S-42 2001271 2017-09-05 2018-09-05Farad Test Software EZ-EMC V1.1.4.2 N/A N/A HP Signal Generator 8665B 3438a00584 2017-07-18 2018-07-18

Sunol Sciences Antenna JB3 A060611-2 2017-08-25 2020-08-25AR Power Amplifier 100W1000M1 13410 N/A N/A AR Power Amplifier 60S1G6 348711 N/A N/A

SCHAFFNER ESD Tester NSG435 005 101 2017-07-10 2018-07-10

* Statement of Traceability: Bay Area Compliance Laboratories Corp. (Dongguan) attests that all calibrations have been performed, traceable to National Primary Standards and International System of Units (SI). Environmental Conditions

Temperature: 25.1~25.9 oC

Relative Humidity: 49~59%*

ATM Pressure: 100.7~101kPa

Tester: Redick Zhang

Test Date: 2018.05.08~2018.05.09

Note: *The relative humidity of ESD test environment is 53%.

Page 9: RXM180306052-02A1 ETSI EN 301 489-1 &3 EMC Report€¦ · Note: This test report is prepared for the customer shown above and for the device described herein. It may not be duplicated

Bay Area Compliance Laboratories Corp. (Dongguan) Report No.: RXM180306052-02A1

ETSI EN 301 489-1 &3 Page 9 of 36

SUMMARY OF TEST RESULTS

SN Rule and Clause Description of Test Test Result

1 EN 301 489 Clause 8.2

Enclosure of ancillary equipment measured on a stand alone basis Compliance

2 EN 301 489 Clause 8.3 DC power input/output ports Not applicable*

3 EN 301 489 Clause 8.4 AC mains power input/output ports Compliance*

4 EN 301 489 Clause 8.5

Harmonic current emissions (AC mains input port) Not applicable**

5 EN 301 489 Clause 8.6

Voltage fluctuations and flicker (AC mains input port) Compliance*

6 EN 301 489 Clause 8.7 Wired network ports Compliance*

7 EN 301 489 Clause 9.2

Radio frequency electromagnetic fields (80 MHz to 6 000 MHz) Compliance

8 EN 301 489 Clause 9.3 Electrostatic discharges Compliance

9 EN 301 489 Clause 9.4 Fast transients, common mode Compliance*

10 EN 301 489 Clause 9.5 Radio frequency, common mode Compliance*

11 EN 301 489 Clause 9.6

Transients and surges in the vehicular environment Not applicable***

12 EN 301 489 Clause 9.7 Voltage dips and short interruptions Compliance*

13 EN 301 489 Clause 9.8 Surges Compliance*

Note: Not applicable*: Test voltage is AC 230V/50Hz. Not applicable**: EUT power is less than 75w. Not applicable***: EUT is not equipment intended for vehicular use. Compliance*:Please refer to the report No.RDG180205051-02.

Page 10: RXM180306052-02A1 ETSI EN 301 489-1 &3 EMC Report€¦ · Note: This test report is prepared for the customer shown above and for the device described herein. It may not be duplicated

Bay Area Compliance Laboratories Corp. (Dongguan) Report No.: RXM180306052-02A1

ETSI EN 301 489-1 &3 Page 10 of 36

1 – ENCLOSURE OF ANCILLARY EQUIPMENT MEASURED ON A STAND ALONE BASIS Measurement Uncertainty Compliance or non- compliance with a disturbance limit shall be determined in the following manner: If Ulab is less than or equal to Ucispr of Table 1, then: –compliance is deemed to occur if no measured disturbance level exceeds the disturbance limit; –non - compliance is deemed to occur if any measured disturbance level exceeds the disturbance limit. If Ulab is greater than Ucispr of Table 1, then: –compliance is deemed to occur if no measured disturbance level, increased by (Ulab − Ucispr), exceeds the disturbance limit; –non - compliance is deemed to occur if any measured disturbance level, increased by (Ulab − Ucispr), exceeds the disturbance limit. Based on CISPR 16-4-2: 2011, measurement uncertainty of radiated emission at a distance of 10m at Bay Area Compliance Laboratories Corp. (Dongguan) is:30M~200MHz: 4.55 dB for Horizontal, 4.57 dB for Vertical; 200M~1GHz: 4.66 dB for Horizontal, 4.56 dB for Vertical; measurement uncertainty of radiated emission at a distance of 3m at Bay Area Compliance Laboratories Corp. (Dongguan) is:30M~200MHz: 4.58 dB for Horizontal, 4.59 dB for Vertical; 200M~1GHz: 4.83 dB for Horizontal, 5.85 dB for Vertical; 1G~6GHz: 4.45 dB, 6G~18GHz: 5.23 dB

Table 1 – Values of Ucispr

Measurement Ucispr

Radiated disturbance (electric field strength at an OATS or in a SAC) (30 MHz to 1000 MHz) Radiated disturbance (electric field strength in a FAR) (1 GHz to 6 GHz) Radiated disturbance (electric field strength in a FAR) (6 GHz to 18 GHz)

6.3 dB5.2 dB5.5 dB

Test System Setup Below 1GHz:

Page 11: RXM180306052-02A1 ETSI EN 301 489-1 &3 EMC Report€¦ · Note: This test report is prepared for the customer shown above and for the device described herein. It may not be duplicated

Bay Area Compliance Laboratories Corp. (Dongguan) Report No.: RXM180306052-02A1

ETSI EN 301 489-1 &3 Page 11 of 36

Above 1GHz:

The radiated emission tests below 1GHz were performed in 10 meters, above 1GHz were performed in the 3 meters. The specification used was EN 55032 Class B limits. The external I/O cables were draped along the test table and formed a bundle 30 to 40 cm long in the middle. The spacing between the peripherals was 10 cm. EMI Test Receiver Setup The system was investigated from 30 MHz to 6 GHz. During the radiated emission test, the EMI test receiver Setup was set with the following configurations:

Frequency Range  RBW  Video B/W  IF B/W  Detector 30 MHz – 1000 MHz  120 kHz  300 kHz  120 kHz  QP 

Above 1 GHz 1MHz  3 MHz  /  Peak 1MHz  10Hz  /  Peak 

Page 12: RXM180306052-02A1 ETSI EN 301 489-1 &3 EMC Report€¦ · Note: This test report is prepared for the customer shown above and for the device described herein. It may not be duplicated

Bay Area Compliance Laboratories Corp. (Dongguan) Report No.: RXM180306052-02A1

ETSI EN 301 489-1 &3 Page 12 of 36

Test Procedure Maximizing procedure was performed on the highest emissions to ensure that the EUT complied with all installation combinations. All data was recorded in the Quasi-peak detection mode from 30MHz to 1GHz, Peak and average detection mode above 1 GHz. Corrected Amplitude & Margin Calculation The basic equation is as follows: Result = Meter Reading+ Corrected Note: Corrected = Antenna Factor + Cable Loss - Amplifier Gain or Corrected = Antenna Factor + Cable Loss + Insertion loss of attenuator - Amplifier Gain The “Margin” column of the following data tables indicates the degree of compliance with the applicable limit. For example, a margin of 7dB means the emission is 7dB below the limit. The equation for margin calculation is as follows: Margin = Limit – Result

Page 13: RXM180306052-02A1 ETSI EN 301 489-1 &3 EMC Report€¦ · Note: This test report is prepared for the customer shown above and for the device described herein. It may not be duplicated

Bay Area Compliance Laboratories Corp. (Dongguan) Report No.: RXM180306052-02A1

ETSI EN 301 489-1 &3 Page 13 of 36

Test Data Please refer to following table and plots: Condition: EN301 489 Polarization: Horizontal EUT: IP Video Intercom Power: AC 230V/50Hz Model: XT-10P Distance: 10m Test Mode: M1 Note:

No. Frequency Reading Detector Corrected Result Limit Margin (MHz) (dBμV) dB/m (dBμV/m) (dBμV/m) (dB)

1 43.5800 37.92 QP -15.02 22.90 30.00 7.10 2 149.3100 28.55 QP -12.85 15.70 30.00 14.30 3 250.1900 44.26 QP -13.56 30.70 37.00 6.30 4 500.4500 33.31 QP -6.21 27.10 37.00 9.90 5 587.7500 26.52 QP -3.52 23.00 37.00 14.00 6 734.2200 23.45 QP -1.45 22.00 37.00 15.00

Page 14: RXM180306052-02A1 ETSI EN 301 489-1 &3 EMC Report€¦ · Note: This test report is prepared for the customer shown above and for the device described herein. It may not be duplicated

Bay Area Compliance Laboratories Corp. (Dongguan) Report No.: RXM180306052-02A1

ETSI EN 301 489-1 &3 Page 14 of 36

Condition: EN301 489 Polarization: Vertical EUT: IP Video Intercom Power: AC 230V/50Hz Model: XT-10P Distance: 10m Test Mode: M1 Note:

No. Frequency Reading Detector Corrected Result Limit Margin (MHz) (dBμV) dB/m (dBμV/m) (dBμV/m) (dB)

1 30.0000 30.71 QP -7.91 22.80 30.00 7.20 2 87.2300 41.76 QP -18.86 22.90 30.00 7.10 3 125.0600 33.72 QP -14.82 18.90 30.00 11.10 4 149.3100 31.65 QP -12.85 18.80 30.00 11.20 5 250.1900 38.96 QP -13.56 25.40 37.00 11.60 6 500.4500 33.21 QP -6.21 27.00 37.00 10.00

Page 15: RXM180306052-02A1 ETSI EN 301 489-1 &3 EMC Report€¦ · Note: This test report is prepared for the customer shown above and for the device described herein. It may not be duplicated

Bay Area Compliance Laboratories Corp. (Dongguan) Report No.: RXM180306052-02A1

ETSI EN 301 489-1 &3 Page 15 of 36

Condition: EN301 489 Polarization: Vertical EUT: IP Video Intercom Power: AC 230V/50Hz Model: XT-10P Distance: 10m Test Mode: M2 Note:

No. Frequency Reading Detector Corrected Result Limit Margin (MHz) (dBμV) dB/m (dBμV/m) (dBμV/m) (dB)

1 32.9100 33.24 QP -9.34 23.90 30.00 6.10 2 45.5200 34.96 QP -16.26 18.70 30.00 11.30 3 250.1900 40.36 QP -13.56 26.80 37.00 10.20 4 411.2100 24.90 QP -8.20 16.70 37.00 20.30 5 587.7500 29.82 QP -3.52 26.30 37.00 10.70 6 749.7400 22.74 QP -1.21 21.53 37.00 15.47

Page 16: RXM180306052-02A1 ETSI EN 301 489-1 &3 EMC Report€¦ · Note: This test report is prepared for the customer shown above and for the device described herein. It may not be duplicated

Bay Area Compliance Laboratories Corp. (Dongguan) Report No.: RXM180306052-02A1

ETSI EN 301 489-1 &3 Page 16 of 36

Condition: EN301 489 Polarization: Horizontal EUT: IP Video Intercom Power: AC 230V/50Hz Model: XT-10P Distance: 10m Test Mode: M2 Note:

No. Frequency Reading Detector Corrected Result Limit Margin (MHz) (dBμV) dB/m (dBμV/m) (dBμV/m) (dB)

1 45.5200 38.76 QP -16.26 22.50 30.00 7.50 2 87.2300 40.46 QP -18.86 21.60 30.00 8.40 3 250.1900 39.16 QP -13.56 25.60 37.00 11.40 4 500.4500 32.91 QP -6.21 26.70 37.00 10.30 5 587.7500 32.02 QP -3.52 28.50 37.00 8.50 6 772.0500 22.93 QP -0.83 22.10 37.00 14.90

Page 17: RXM180306052-02A1 ETSI EN 301 489-1 &3 EMC Report€¦ · Note: This test report is prepared for the customer shown above and for the device described herein. It may not be duplicated

Bay Area Compliance Laboratories Corp. (Dongguan) Report No.: RXM180306052-02A1

ETSI EN 301 489-1 &3 Page 17 of 36

Condition: EN 301489 Class B(PeaK) Polarization: Horizontal EUT: IP Video Intercom Power: AC 230V/50Hz Model: XT-10P Distance: 3m Test Mode: M1 Note:

No. Frequency Reading Detector Corrected Result Limit Margin (MHz) (dBμV) dB/m (dBμV/m) (dBμV/m) (dB)

1 1737.500 50.93 peak -8.20 42.73 70.00 27.27 2 1737.500 40.38 AVG -8.20 32.18 50.00 17.82 3 1800.000 52.40 peak -7.77 44.63 70.00 25.37 4 1800.000 42.43 AVG -7.77 34.66 50.00 15.34 5 2412.500 56.42 peak -6.47 49.95 70.00 20.05 6 2412.500 46.57 AVG -6.47 40.10 50.00 9.90

Page 18: RXM180306052-02A1 ETSI EN 301 489-1 &3 EMC Report€¦ · Note: This test report is prepared for the customer shown above and for the device described herein. It may not be duplicated

Bay Area Compliance Laboratories Corp. (Dongguan) Report No.: RXM180306052-02A1

ETSI EN 301 489-1 &3 Page 18 of 36

Condition: EN 301489 Class B(PeaK) Polarization: Vertical EUT: IP Video Intercom Power: AC 230V/50Hz Model: XT-10P Distance: 3m Test Mode: M1 Note:

No. Frequency Reading Detector Corrected Result Limit Margin (MHz) (dBμV) dB/m (dBμV/m) (dBμV/m) (dB)

1 1000.0000 48.21 peak -10.77 37.44 70.00 32.56 2 1000.0000 38.46 AVG -10.77 27.69 50.00 22.31 3 1192.500 47.40 peak -9.99 37.41 70.00 32.59 4 1192.500 37.52 AVG -9.99 27.53 50.00 22.47 5 2412.500 50.81 peak -6.47 44.34 70.00 25.66 6 2412.500 40.58 AVG -6.47 34.11 50.00 15.89

Page 19: RXM180306052-02A1 ETSI EN 301 489-1 &3 EMC Report€¦ · Note: This test report is prepared for the customer shown above and for the device described herein. It may not be duplicated

Bay Area Compliance Laboratories Corp. (Dongguan) Report No.: RXM180306052-02A1

ETSI EN 301 489-1 &3 Page 19 of 36

Condition: EN 301489 Class B(PeaK) Polarization: Horizontal EUT: IP Video Intercom Power: AC 230V/50Hz Model: XT-10P Distance: 3m Test Mode: M2 Note:

No. Frequency Reading Detector Corrected Result Limit Margin (MHz) (dBμV) dB/m (dBμV/m) (dBμV/m) (dB)

1 1440.000 48.12 peak -9.36 38.76 70.00 31.24 2 1440.000 38.33 AVG -9.36 28.97 50.00 21.03 3 1975.000 55.52 peak -7.27 48.25 70.00 21.75 4 1975.000 45.92 AVG -7.27 38.65 50.00 11.35 5 4285.000 47.22 peak -1.84 45.38 74.00 28.62 6 4285.000 38.09 AVG -1.84 36.25 54.00 17.75

Page 20: RXM180306052-02A1 ETSI EN 301 489-1 &3 EMC Report€¦ · Note: This test report is prepared for the customer shown above and for the device described herein. It may not be duplicated

Bay Area Compliance Laboratories Corp. (Dongguan) Report No.: RXM180306052-02A1

ETSI EN 301 489-1 &3 Page 20 of 36

Condition: EN 301489 Class B(PeaK) Polarization: Vertical EUT: IP Video Intercom Power: AC 230V/50Hz Model: XT-10P Distance: 3m Test Mode: M2 Note:

No. Frequency Reading Detector Corrected Result Limit Margin (MHz) (dBμV) dB/m (dBμV/m) (dBμV/m) (dB)

1 1205.000 50.32 peak -9.95 40.37 70.00 29.63 2 1205.000 41.20 AVG -9.95 31.25 50.00 18.75 3 1762.500 55.31 peak -8.04 47.27 70.00 22.73 4 1762.500 45.73 AVG -8.04 37.69 50.00 12.31 5 1957.500 58.88 peak -7.33 51.55 70.00 18.45 6 1957.500 48.76 AVG -7.33 41.43 50.00 8.57

Page 21: RXM180306052-02A1 ETSI EN 301 489-1 &3 EMC Report€¦ · Note: This test report is prepared for the customer shown above and for the device described herein. It may not be duplicated

Bay Area Compliance Laboratories Corp. (Dongguan) Report No.: RXM180306052-02A1

ETSI EN 301 489-1 &3 Page 21 of 36

7 – RADIO FREQUENCY ELECTROMAGNETIC FIELDS (80 MHZ TO 6 000 MHZ) Test System Setup Note:d=3m(below 1G)/1m(above 1G); Test Level

Level Field Strength V/m 1. 12. 33. 10X. Special

Performance Criterion: A Test Procedure

The EUT and its simulators are placed on a turn table which is 0.8 meter above the ground. The EUT is set 3 meters away from the Receiving antenna which is mounted on an antenna tower. Both horizontal and vertical polarizations of the antenna are set on test. Each of the four sides of EUT must be faced this Receiving antenna and measured individually. In order to judge the EUT performance, a CCD camera and C313 were used to monitor the EUT.

d EUT

System

80 cm

Anechoic Chamber

Power Amplifier

Signal Generator

Wooden table

Page 22: RXM180306052-02A1 ETSI EN 301 489-1 &3 EMC Report€¦ · Note: This test report is prepared for the customer shown above and for the device described herein. It may not be duplicated

Bay Area Compliance Laboratories Corp. (Dongguan) Report No.: RXM180306052-02A1

ETSI EN 301 489-1 &3 Page 22 of 36

Test Data Please refer to following tables: Test Mode: M1,M2 Note:

Condition of Test Remarks Field Strength 3 V/m (Test Level 2)

RF Signal 1 kHz, 80% AM, sine wave Sweep Frequency Step 1%, logarithmic

Dwell Time 1 Sec Frequency

Range (MHz)

Front Side Rear Side Left Side Right Side VERT HORI VERT HORI VERT HORI VERT HORI

80-1000 A A A A A A A A

1000-6000 A A A A A A A A

Test Setup Photo-M1

Page 23: RXM180306052-02A1 ETSI EN 301 489-1 &3 EMC Report€¦ · Note: This test report is prepared for the customer shown above and for the device described herein. It may not be duplicated

Bay Area Compliance Laboratories Corp. (Dongguan) Report No.: RXM180306052-02A1

ETSI EN 301 489-1 &3 Page 23 of 36

Test Setup Photo-M2

Page 24: RXM180306052-02A1 ETSI EN 301 489-1 &3 EMC Report€¦ · Note: This test report is prepared for the customer shown above and for the device described herein. It may not be duplicated

Bay Area Compliance Laboratories Corp. (Dongguan) Report No.: RXM180306052-02A1

ETSI EN 301 489-1 &3 Page 24 of 36

8 – ELECTROSTATIC DISCHARGES Test System Setup EN 61000-4-2 specifies that a tabletop EUT shall be placed on a non-conducting table which is 80 centimeters above a ground reference plane and that floor mounted equipment shall be placed on a insulating support approximately 10 centimeters above a ground plane. During the tests, the EUT is positioned over a ground reference plane in conformance with this requirement. For tabletop equipment, a 1.6 by 0.8-meter metal sheet (HCP) is placed on the table and connected to the ground plane via a metal strap with two 470 k Ohms resistors in series. The EUT and attached cables are isolated from this metal sheet by 0.5-millimeter thick insulating material. A Vertical Coupling Plane (VCP) grounded on the ground plane through the same configuration as in the HCP is used. Test Level

Level Test Voltage Contact Discharge (±kV)

Test Voltage Air Discharge (±kV)

1. 2 2 2. 4 4 3. 6 8 4. 8 15 X. Special Special

Test Level 3 for Air Discharge at ±8 kV Test Level 2 for Direct Discharge at ±4 kV

Performance criterion: B

AC Mains

EUT System

ESD Tester

Wooden Table

Remark: is the tip of the electrode

80

Adapter

Page 25: RXM180306052-02A1 ETSI EN 301 489-1 &3 EMC Report€¦ · Note: This test report is prepared for the customer shown above and for the device described herein. It may not be duplicated

Bay Area Compliance Laboratories Corp. (Dongguan) Report No.: RXM180306052-02A1

ETSI EN 301 489-1 &3 Page 25 of 36

Test Procedure Air Discharge:

This test is done on a non-conductive surface. The round discharge tip of the discharge electrode shall be approached as fast as possible to touch the EUT. After each discharge, the discharge electrode shall be removed from the EUT. The generator is then re-triggered for a new single discharge and repeated 10 times for each pre-selected test point. This procedure shall be repeated until all the air discharge completed.

Contact Discharge:

All the procedure shall be same as Section 8.3.1 of EN 61000-4-2, except that the tip of the discharge electrode shall touch the EUT before the discharge switch is operated.

Indirect discharge for horizontal coupling plane

At least 50 single discharges shall be applied to the horizontal coupling plane, at points on each side of the EUT. The discharge electrode positions vertically at a distance of 0.1m from the EUT and with the discharge electrode touching the coupling plane.

Indirect discharge for vertical coupling plane

At least 50 single discharges shall be applied to the center of one vertical edge of the coupling plane. The coupling plane, of dimensions 0.5m X 0.5m, is placed parallel to, and positioned at a distance of 0.1m from the EUT. Discharges shall be applied to the coupling plane, with this plane in sufficient different positions that the four faces of the EUT are completely illuminated.

Page 26: RXM180306052-02A1 ETSI EN 301 489-1 &3 EMC Report€¦ · Note: This test report is prepared for the customer shown above and for the device described herein. It may not be duplicated

Bay Area Compliance Laboratories Corp. (Dongguan) Report No.: RXM180306052-02A1

ETSI EN 301 489-1 &3 Page 26 of 36

Test Data Please refer to following tables: Test Mode: M1,M2 Note: Table 1: Electrostatic Discharge Immunity (Air Discharge)

Test Points Location Test Levels -2 kV +2 kV -4 kV +4 kV -8 kV +8 kV -15 kV +15 kV

Plastic Shell A A A A A A / / Port A A A A A A / / Seam A A A A A A / / Camera A A A A A A / /

Table 2: Electrostatic Discharge Immunity (Direct Contact)

Test Points Location Test Levels -2 kV +2 kV -4 kV +4 kV -6 kV +6 kV -8 kV +8 kV

Screw A A A A Button A A A A Metal Shell A A A A / / / / RJ45 Port A A A A / / / /

Table 3: Electrostatic Discharge Immunity (Indirect Contact HCP)

Test Points Location Test Levels -2 kV +2 kV -4 kV +4 kV -6 kV +6 kV -8 kV +8 kV

Front Side A A A A / / / / Back Side A A A A / / / / Left Side A A A A / / / / Right Side A A A A / / / /

Table 4: Electrostatic Discharge Immunity (Indirect Contact VCP)

Test Points Location Test Levels -2 kV +2 kV -4 kV +4 kV -6 kV +6 kV -8 kV +8 kV

Front Side A A A A / / / / Back Side A A A A / / / / Left Side A A A A / / / / Right Side A A A A / / / /

Page 27: RXM180306052-02A1 ETSI EN 301 489-1 &3 EMC Report€¦ · Note: This test report is prepared for the customer shown above and for the device described herein. It may not be duplicated

Bay Area Compliance Laboratories Corp. (Dongguan) Report No.: RXM180306052-02A1

ETSI EN 301 489-1 &3 Page 27 of 36

ESD Location Photo

Air Discharge: Direct Contact:

Page 28: RXM180306052-02A1 ETSI EN 301 489-1 &3 EMC Report€¦ · Note: This test report is prepared for the customer shown above and for the device described herein. It may not be duplicated

Bay Area Compliance Laboratories Corp. (Dongguan) Report No.: RXM180306052-02A1

ETSI EN 301 489-1 &3 Page 28 of 36

M1 Test Setup Photo

M2 Test Setup Photo

Page 29: RXM180306052-02A1 ETSI EN 301 489-1 &3 EMC Report€¦ · Note: This test report is prepared for the customer shown above and for the device described herein. It may not be duplicated

Bay Area Compliance Laboratories Corp. (Dongguan) Report No.: RXM180306052-02A1

ETSI EN 301 489-1 &3 Page 29 of 36

EXHIBIT A – EUT PHOTOGRAPHS

EUT – All View

EUT – Bottom View

Page 30: RXM180306052-02A1 ETSI EN 301 489-1 &3 EMC Report€¦ · Note: This test report is prepared for the customer shown above and for the device described herein. It may not be duplicated

Bay Area Compliance Laboratories Corp. (Dongguan) Report No.: RXM180306052-02A1

ETSI EN 301 489-1 &3 Page 30 of 36

EUT – Side View

EUT – Label View

Page 31: RXM180306052-02A1 ETSI EN 301 489-1 &3 EMC Report€¦ · Note: This test report is prepared for the customer shown above and for the device described herein. It may not be duplicated

Bay Area Compliance Laboratories Corp. (Dongguan) Report No.: RXM180306052-02A1

ETSI EN 301 489-1 &3 Page 31 of 36

EUT – Port View

Page 32: RXM180306052-02A1 ETSI EN 301 489-1 &3 EMC Report€¦ · Note: This test report is prepared for the customer shown above and for the device described herein. It may not be duplicated

Bay Area Compliance Laboratories Corp. (Dongguan) Report No.: RXM180306052-02A1

ETSI EN 301 489-1 &3 Page 32 of 36

EXHIBIT B – TEST SETUP PHOTOGRAPHS

RE Below 1G Front-M1 View

RE Below 1G Rear-M1 View

Page 33: RXM180306052-02A1 ETSI EN 301 489-1 &3 EMC Report€¦ · Note: This test report is prepared for the customer shown above and for the device described herein. It may not be duplicated

Bay Area Compliance Laboratories Corp. (Dongguan) Report No.: RXM180306052-02A1

ETSI EN 301 489-1 &3 Page 33 of 36

RE Below 1G Front-M2 View

RE Below 1G Rear-M2 View

Page 34: RXM180306052-02A1 ETSI EN 301 489-1 &3 EMC Report€¦ · Note: This test report is prepared for the customer shown above and for the device described herein. It may not be duplicated

Bay Area Compliance Laboratories Corp. (Dongguan) Report No.: RXM180306052-02A1

ETSI EN 301 489-1 &3 Page 34 of 36

RE Above 1G Front-M1 View

RE Above 1G Rear-M1 View

Page 35: RXM180306052-02A1 ETSI EN 301 489-1 &3 EMC Report€¦ · Note: This test report is prepared for the customer shown above and for the device described herein. It may not be duplicated

Bay Area Compliance Laboratories Corp. (Dongguan) Report No.: RXM180306052-02A1

ETSI EN 301 489-1 &3 Page 35 of 36

RE Above 1G Front-M2 View

RE Above 1G Rear-M2 View

Page 36: RXM180306052-02A1 ETSI EN 301 489-1 &3 EMC Report€¦ · Note: This test report is prepared for the customer shown above and for the device described herein. It may not be duplicated

Bay Area Compliance Laboratories Corp. (Dongguan) Report No.: RXM180306052-02A1

ETSI EN 301 489-1 &3 Page 36 of 36