SCHWERDT DESIGN GROUP, INC Architecture Interiors Planning
Topeka, Kansas Oklahoma City, Oklahoma
ADDENDUM NO. 1 BLDG A - ADD-1, REV-1 Page 1 of 2
2231 SW Wanamaker Rd. Suite 303 Topeka, Kansas 66614-4275 785.273.7540 www.sdgarch.com
ADDENDUM NO. 1
DATE:
October 2, 2019 10/02/19
PROJECT NO: 190121 AE Gage Center – Building A
RE:
Drawing Revisions
You are instructed to read and to note the following described changes, corrections, clarifications, omissions, deletions, additions and statements pertinent to the Contract Bid and Construction Documents: The Addendum No. 1 is part of the contract Bid and Construction Documents and shall govern in the performance of the Work. Architectural Items: A-1 Sheet A-101 – BUIDLING A – FIRST FLOOR PLAN: Mark South stone wing wall as similar to North stone
wing wall 2/A-301.
A-2 Sheet A-102 – BUILDING A – SECOND FLOOR PLAN:
A-2.A Remove Alternate A1 for the area in the NW corner of the second floor.
A-2.B Remove doors A201 and A220 and walls associated.
A-2.C Remove plan note (6) from the plan note legend.
A-3 Sheet A-112 – REFLECTED CEILING PLAN – BUILDING A – SECOND FLOOR
A-3.A Alternate A1 has been removed from the project
A-3.B Add detail mark 13/A-501 at West soffit Roof drain
A-4 Sheet A-121 – ROOF PLAN – BUILDING A: Add detail mark 13/A-501 at West soffit roof drain
A-5 Sheet A-301 – WALL SECTIONS – BUILDING A:
A-5.A Section 2/A-301 – Building A – Small Fin: Added steel to top of wall, REF STRUCT.
A-6 Sheet A-501 – BUILDING A – DETAILS:
A-6.A 12/A-501 – STONE WALL BRACING AT ROOF: Sealant is required at TPO to flashing joint, typ.
A-6.B ADD detail 13/A-501 – PARAPET AT ROOF DRAIN
A-7 Sheet A-601 – DOOR SCHEDULE:
A-7.A Remove doors A201 and A220
A-7.B Remove all notes referring to alternate A1
A-8 Sheet A-604 – ROOM FINISH SCHEDUEL: Acoustic Panels: PoshFelt shall be considered an acceptable
alternate to FilzFelt
A-9 Specification Section 071326 – SELF-ADHERING SHEET WATERPROOFING: Subject to compliance with
requirements add the following manufacturers and products as approved equals to section 2.1 SHEET
ADDENDUM NO. 1 BLDG A - ADD-1, REV-1 Page 2 of 2
2231 SW Wanamaker Rd. Suite 303 Topeka, Kansas 66614-4275 785.273.7540 www.sdgarch.com
WATERPROOFING FOR VERTICAL APPLICATION: Carlisle Coating & Waterproofing, MiraDRI 860/861:
Polyguard Products, Inc., 650 Membrane; W. R. Meadows, Inc., MEL-ROL.
A-10 Specification Section 071326 – SELF-ADHERING SHEET WATERPROOFING: Subject to compliance with
requirements add the following manufacturers and products as approved equals to section 2.2 SHEET
WATERPROOFING FOR VERTICAL BLIND-SIDE APPLICATION: Carlisle Coating & Waterproofing, Miraply;
Polyguard Products Inc., Underseal Blindside Membrane; W. R. Meadows, Inc., PRECON.
A-11 Specification Section 071326 – SELF-ADHERING SHEET WATERPROOFING: Subject to compliance with
requirements add the following manufacturers and products as approved equals to section 2.4
MOLDED-SHEET DRAINAGE PANELS: Polyguard Products, Inc., Polyflow 15.
A-12 Specification Section 072100-THERMAL INSULATION: Add the following manufacturer to the list of
available manufacturers in section 2.1 POLYISOCYANURATE FOAM-PLASTIC BOARD: Carlisle Coating &
Waterproofing, R2+ SHEATHE.
A-13 Specification Section 072726 – FLUID-APPLIED WEATHER BARRIERS: Subject to compliance with
requirements add the following manufacturers and products as approved equals to section 2.1 VAPOR-
PERMEABLE MEMBRANE AIR BARRIER: Carlisle Coating & Waterproofing, Barrithane VP: Polyguard
Products, Inc., Airlok Flex VP; Prosoco Inc., R-Guard Spray Wrap MVP; TK Poducts, AirMax, 2104 VP.
A-14 Specification Section 081113 HOLLOW METAL DOORS & FRAMES: Add the following manufacturer to the
list of available manufacturers in section 2.1 MANUFACTURERS: Mesker Door Inc.
A-15
Mechanical/Electrical Items: ME-1 Sheet T-102: Added data cable within outlet designation for TV outlet in room A105. Refer to revised
sheet T-102.
ME-2 Sheet T-103: Added data outlet for room scheduler outside of room A213. Refer to revised sheet T-103.
ME-3 Sheet T-202: Added cable outlet designation for the video intercom stations at doors A101.1 and AS1N.
Refer to revised sheet T-202.
ME-4 Sheet T-202: Removed the card readers from doors A111 and A110. Refer to revised sheet T-202.
ME-5 Sheet T-203: Removed card readers at doors A201 and A220. Refer to revised sheet T-203.
ME-6 Sheet E-409: Light Fixture Schedule has been updated. Refer to the attached.
END OF ADDENDUM
UP
DN
DN
UP
A-201
3
1 3 4 5 6 7 8 9
AA
BB
CC
1.5 2
8' -
4 1
/8"
18' - 8 3/8"
7' -
7 1
/8"
24' -
0"
5' -
2 7
/8"
11' -
8 3
/4"
CAB
6' - 0"
CA
B
3' -
6"
1
A-301
MECHCHASE
CO2
7' - 0"
7' -
0"
WINDOW WELL W/ NEW GRATE, TYP.
3' - 0" 3' - 0"
3' -
0"
10' -
0"
10' - 6" 4' - 6"
FOUNDERSOFFICE
A124
JAN
A123
TR
AN
SF
OR
ME
R
LOBBY
A102
RECEPTION
A104
WAITING
A103
11' - 6" +/- 8' - 1" 59' - 11 3/16" 9' - 1 1/2" 2' - 2" 9' - 2 1/2" 9' - 10 7/8" 9' - 9 1/2"
STORAGE
A113
IT
A112TRAFFIC
STORAGE
A114
MENS
A118WOMENS
A117
FOCUS
A108
OPEN OFFICE
A109
TRAFFIC
A110
VESTIBULE
A101
A-401
1
7' -
10 1
/8"
+/-
HUDDLE
A106
CONFERENCE
A105
CORRIDOR
A107
BREAK
A111
RAMP
A115
CORRIDOR
A116
OPEN OFFICE
A119
RAMP
A121OPEN OFFICE
A122
ELEV LOBBY
A125
STAIR
AS1S
ELEV
AE1
STAIR
AS1N
6M
3' x
4' M
B-1
3' x
4' M
B-1
1
A125.1
A112
A113
A114
A117
A118
A123
20' -
0"
12' - 0"
TR
AS
H E
NC
LOS
UR
E
AS-103
C5
1
A-3022
A-302
A-501
2
AS1S
A122
A110
A111
11' - 6" 7' - 9 1/2" 2"
A-205
C1
A-205
A3
A105
A-205
D1
A106
6M
2
A-301
55
B5
A-305 A-305
B1
A B B C
D
E
FBB G
H
H
I
J
KL
J
O
N
M
A-305
C1
FI
JI
CI
T
II
DI
A101.1
1' - 0" 6"
HI
A-205
C2
A-401 3
GI
EI
4S(1)
7' -
0"
4S(1)
3Ma
3Ma
A108
13' - 8 1/2"
3Ma
3Ma
3Ma
2' - 3"
A-205
B1
A1
A101
.2
A-205 D4
A-205 C4
14' - 11 1/2"4' - 6"
4' - 2 1/2"
15' - 6 1/2"5' - 5"
A115
AS1N
B3
AI
BI
FEC
B5
A-305
8' -
2"
1' - 6"
3' - 2"
0Fa0Fa0Fa0Fa0Fa0Fa
2
FEC8M
8M
2
2
2
2 2
2
2
2
2
15
16
17
18
14
14
14
6"
1' - 6"
8' -
11"
1' -
10"
6' -
6"
2
4S(1)
4S(1)
4S(1)
12
13
20
20
20
202' - 0"+
-2' - 0"
0' - 0"
1111
11
11
11
4' x
6' M
B-1
11
11
11
11
11
11
11
11
11
ICE COFFEE/TEA
2 MICRO
DW
REF REF
(3 THUS)
13"
A-205
D5
A-2011
A-201 2
21
A124
B5
A-305
7' -
10 1
/2"
SOFFIT ABOVE
4' -
7 1
/4"
A125.2
LI
2
A-301
SIM
1
GENERAL PLAN NOTES:
1. CONTRACTOR TO VERIFY EXISTING SITE AND BUILDING CONDITIONS.
2. CONTRACTOR TO PROVIDE BLOCKING, AS REQUIRED, FOR ALL WALL MOUNTED ELEMENTS, TO INCLUDE BUT NOT LIMITED TO SHELVING, EQUIPMENT, HANDRAILS, MARKERBOARDS (MB), DIGITAL DISPLAYS
(TV) ETC.3. VERIFY REQUIREMENTS OF ALL OWNER FURNISHED
ITEMS WITH OWNER BEFORE PROCEEDING W/ WORK.4. ALL INTERIOR WALLS SHALL BE TYPE (3M) UNLESS
NOTED OTHERWISE.5. ALL INTERIOR FURRING ON EXTERIOR MASONRY OR
CONCRETE WALLS SHALL BE TYPE (0Fa) UNLESS NOTED OTHERWISE
6. ALL EXTERIOR WINDOWS SHALL BE PROVIDED WITH ROLLER WINDOW SHADES, TYPICAL. REFERENCE FRAME ELEVATIONS, PLAN NOTES AND SPECIFICATIONS.
7. REFERENCE MEP FOR ALL MECHANICAL EQUIPEMENT NOT INDICATED IN PLANS AND DETAILS. NOTIFY ARCHITECT OF ANY DISCREPANCIES.
8. ALL NEW AND EXISTING PARTITIONS TO BE PAINTED UNLESS NOTED OTHERWISE.
9. OWNER PROVIDED PROJECTORS AND DROP DOWN SCREENS, WHERE INDICATED, TO BE COORDINATED WITH OWNERS A/V PROVIDER.
10. ALL EXPOSED STEEL TO BE PREPPED AND PAINTED
PLAN NOTES:
PIPING CHASE, REF MEP; CHASE IS CONTINUOUS VERTICALLY THROUGH LEVEL 1 & 2, TYP. - REF PLANS
TV AND MOUNT, BY OWNER; COORDINATE W/ MEP; COORDINATE W/ OWNER FOR EXACT MOUNTING LOCATION; GC TO PROVIDE BLOCKING / ANCHORING AS REQUIRED FOR TV MOUNT
OVERHEAD PROJECTOR & SCREEN, BY OWNER; BLOCKING / BRACING FOR MOUNTING BY GC; REF MEP FOR LOCATION COORDINATION; COORDINATE W/ OWNER & OWNER'S AV CONSULTANT AS REQUIRED FOR EQUIPMENT LOCATION,TYP.
PROVIDE NEW STEEL ROOF ACCESS LADDER IN ACCORDANCE W/ OSHA 1926, ENSURE LADDER IS SLIP RESISTANT AND EQUIPPED WITH A POLE EXTENSION LADDER SAFETY DEVICE.
ELECTRICAL PANEL, FULLY RECESSED IN LOCATIONS WHERE A MIN. 6" STUD WALL HAS BEEN PROVIDED; REF ELECT
ALTERNATE REMOVED FROM PROJECT IN ADDENDUM #1
NEW FLOOR SINK, REF PLUMBING
INFILL OPENING WITH CMU TO MATCH EXISTING, TOOTH IN NEW CMU
PROVIDE NEW HANDRAIL, REF TYP. DETAIL; HANDRAIL MUST EXTEND PAST RISER A MIN OF 12" AT TOP AND BOTTOM OF STAIR.
INFILL OPENING WITH METAL STUD, SOUND ATTINUATING BATT INSULATION AND GYPSUM WALL BOARD PARTITION; MATCH EXISTING ADJACENT WALL THICKNESS AND FINISH
CORNER GUARD REQUIRED, CG-1 REF A-604 FINISH LEGEND
OWNER PROVIDED SODA MACHINE, PROVIDE CONDUIT REQUIRED FOR SYRUP LINES AND CO2 TO ADJACENT STORAGE ROOM, REF MEP
OWNER PROVIDED BREAK ROOM EQUIPMENT INCLUDES BUT IS NOT LIMITED TO: (2) REFRIGERATORS, (2) MICROWAVES, COFFEE MACHINE, COMMERCIAL COFFEE GRINDER, TEA MACHINE AND ICE MACHINE; REF PLUMBING FOR REQUIRED WATER LINES AND FLOOR DRAINS AND ELECT FOR POWER REQUIREMENTS
OWNER PROVIDED ROOM SCHEDULER, REF TELECOM FOR CONTRACTOR INSTALLED INFRASTRUCTURE REQUIREMETS
BACK-LIT SIGNAGE BY OWNER, COORDINATE W/ OWNERS SIGNAGE PROVIDER FOR ELECTRICAL AND BLOCKING REQUIREMENTS
ESD FLOOR TILE REQUIRES GROUNDING, REF FINISH SCHEDULE AND ELECT.
SAW CUT FLOOR FOR FLOOR BOX AND CABELING AS REQUIRED, REF ELECT AND TELECOM
ACCESS CONTROL REQUIRED AT ELEVATOR TO RESTRICT ACCESS TO CERTAIN LEVELS. COORDINATE TRAVELING CABLE REQUIREMENTS WITH OWNERS ACCESS CONTROL PROVIDER.
REMOVE GWB WITH ORANGE PEEL TEXTURE AND REPLACE WITH NEW GWB, TYP.
CONCRETE FLOOR AND METAL DECK INFILL, REF STRUCT
ROOF DRAIN LEADER, REF PLUMBING
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
SHEET TITLE
PROJECT NUMBER
SHEET NUMBER
schwerdt design grouparchitecture interiors planning2231 sw wanamaker rd suite 303
A
B
C
D
54321
A
B
C
D
FILE
PA
TH:
DA
TE:
DR
AW
N B
Y:
54321
topeka, kansas 66614-4275phone: 785.273.7540fax: 785.273.7579
500 north broadway suite 200oklahoma city, ok 73102phone: 405.231.3105fax: 405.231.3115
SUBMISSION DATES
C:\U
sers
\Laure
n.S
DG
-SC
I\D
ocum
ents
\2019 0
9-1
6_190121 A
E P
rofe
ssio
nal B
uild
ing P
hase 1
Rem
odel_
Laure
n.r
vt
10/3
/2019 1
1:2
0:3
4 A
M
AD
VIS
OR
S E
XC
EL
-GA
GE
CE
NTE
R C
AM
PU
S
PH
AS
E 1
-B
UIL
DIN
G A
-R
EM
OD
EL
TOP
EK
A, K
AN
SA
S 6
6604
BUILDING A - FIRST FLOORPLAN
190121
A-101
Aut
hor
SCALE: 1/8" = 1'-0"1
BUILDING A - FIRST FLOOR PLAN
PLAN LEGEND & NOTES
N
1
ADD-1, REV #1 10/02/2019
DN
DN
A-2011
A-201
A-201
4
3
1 3 4 5 6 7 8 9
A
B
C
1.5 2
20' - 0" 20' - 0" 20' - 0" 20' - 0" 20' - 0" 20' - 0" 19' - 1 1/2"
5' -
0"
9' -
10"
ADA
MECHCHASE
1
A-301
MECH CHASE
ADAA/V
A215
14' - 10 1/2" 19' - 4 1/2"
MENS
A218
WOMENS
A219
MOTHERS RM
A221
TRAINING
A222
LOUNGE
A220
8' - 1 1/2" +/-
5' -
10"
19' -
0"
6' -
2 1
/2"
27' -
10 1
/2"
+/-
7' - 0 7/8"1' - 6"
MGR OFFICE
A216
CONFERENCE
A213
BREAK ROOM
A209 TEAM
A211
6' - 0"
ELEV
AE2JAN
A203
ELEV LOBBY
A204
STAIR
AS2S
ELEC
A205
COPY/PRINT
A207
HUDDLE
A208
HUDDLE
A210
HUDDLE
A212
MGR OFFICE
A214
TYP.1' - 0"
TY
P.
1' -
0"
4' -
1 1
/2"
12' - 5 1/2"
STAIR
AS2N
OPEN OFFICE
A201
OPEN OFFICE
A206
ELEC
A217
1
4' X
6' M
B-1
PROJECTOR SCREEN
4' X 6' MB-1
3' X
4' M
B-1
3' X
4' M
B-1
3' X
4' M
B-1
3' X
4' M
B-1
A207
A219
A218
A221
A221.1
A221.2
A221
.3
AS2S
A217
A209
A213
A216
A215
1
A-3022
A-302
AS2N
A205
A203
A-401
2
2
A-301
A208
A210
A212
A214
A213
.2
OP P P Q PQ R
UT T T T
TT
S
H
H
O
KI
A-205
A-205 B2D3
A-205
D2
5' - 11" 12' - 0"
A-205C3
9' - 0 1/2" 5' - 11"
3
A-501
A222
SLOPETAPERED CRICKET INSULATION, TYP.
PRE-FINISHED METAL COPING, TYP.
RD
4S(1)
4S(1)
4S(1)
4S(1)
3M
3M
10
3M
10
141410
4S(1)10
5
5
9
4
8
1919
2
3' X
4' M
B-1 2 2 2
19
19
2
2
22
1' - 6"
3' -
6"
4S(1)
22
13
2
2
19' - 1 1/2"
11
11
11 11(3 THUS)
11(4 THUS)
11(4 THUS)
11(4 THUS) 11
(4 THUS)11
(4 THUS)11
(4 THUS)11
(4 THUS)
11
11
11
11
REF
RE
FR
EF
ICE
CO
F-
FE
E
DW
MIC
RO
MIC
RO
11 11
11
11
11
11
A-205C5
A-205B4
A-205B5
A4
I
N
OVERFLOW SCUPPER, PLACE 2" MIN ABOVE ROOF DRAIN LEVEL
A-501
6
REST. VEST.
A224
CORRIDOR
A2251
1
1
2
A-301
SIM
GENERAL PLAN NOTES:
1. CONTRACTOR TO VERIFY EXISTING SITE AND BUILDING CONDITIONS.
2. CONTRACTOR TO PROVIDE BLOCKING, AS REQUIRED, FOR ALL WALL MOUNTED ELEMENTS, TO INCLUDE BUT NOT LIMITED TO SHELVING, EQUIPMENT, HANDRAILS, MARKERBOARDS (MB), DIGITAL DISPLAYS
(TV) ETC.3. VERIFY REQUIREMENTS OF ALL OWNER FURNISHED
ITEMS WITH OWNER BEFORE PROCEEDING W/ WORK.4. ALL INTERIOR WALLS SHALL BE TYPE (3M) UNLESS
NOTED OTHERWISE.5. ALL INTERIOR FURRING ON EXTERIOR MASONRY OR
CONCRETE WALLS SHALL BE TYPE (0Fa) UNLESS NOTED OTHERWISE
6. ALL EXTERIOR WINDOWS SHALL BE PROVIDED WITH ROLLER WINDOW SHADES, TYPICAL. REFERENCE FRAME ELEVATIONS, PLAN NOTES AND SPECIFICATIONS.
7. REFERENCE MEP FOR ALL MECHANICAL EQUIPEMENT NOT INDICATED IN PLANS AND DETAILS. NOTIFY ARCHITECT OF ANY DISCREPANCIES.
8. ALL NEW AND EXISTING PARTITIONS TO BE PAINTED UNLESS NOTED OTHERWISE.
9. OWNER PROVIDED PROJECTORS AND DROP DOWN SCREENS, WHERE INDICATED, TO BE COORDINATED WITH OWNERS A/V PROVIDER.
10. ALL EXPOSED STEEL TO BE PREPPED AND PAINTED
PLAN NOTES:
PIPING CHASE, REF MEP; CHASE IS CONTINUOUS VERTICALLY THROUGH LEVEL 1 & 2, TYP. - REF PLANS
TV AND MOUNT, BY OWNER; COORDINATE W/ MEP; COORDINATE W/ OWNER FOR EXACT MOUNTING LOCATION; GC TO PROVIDE BLOCKING / ANCHORING AS REQUIRED FOR TV MOUNT
OVERHEAD PROJECTOR & SCREEN, BY OWNER; BLOCKING / BRACING FOR MOUNTING BY GC; REF MEP FOR LOCATION COORDINATION; COORDINATE W/ OWNER & OWNER'S AV CONSULTANT AS REQUIRED FOR EQUIPMENT LOCATION,TYP.
PROVIDE NEW STEEL ROOF ACCESS LADDER IN ACCORDANCE W/ OSHA 1926, ENSURE LADDER IS SLIP RESISTANT AND EQUIPPED WITH A POLE EXTENSION LADDER SAFETY DEVICE.
ELECTRICAL PANEL, FULLY RECESSED IN LOCATIONS WHERE A MIN. 6" STUD WALL HAS BEEN PROVIDED; REF ELECT
ALTERNATE REMOVED FROM PROJECT IN ADDENDUM #1
NEW FLOOR SINK, REF PLUMBING
INFILL OPENING WITH CMU TO MATCH EXISTING, TOOTH IN NEW CMU
PROVIDE NEW HANDRAIL, REF TYP. DETAIL; HANDRAIL MUST EXTEND PAST RISER A MIN OF 12" AT TOP AND BOTTOM OF STAIR.
INFILL OPENING WITH METAL STUD, SOUND ATTINUATING BATT INSULATION AND GYPSUM WALL BOARD PARTITION; MATCH EXISTING ADJACENT WALL THICKNESS AND FINISH
CORNER GUARD REQUIRED, CG-1 REF A-604 FINISH LEGEND
OWNER PROVIDED SODA MACHINE, PROVIDE CONDUIT REQUIRED FOR SYRUP LINES AND CO2 TO ADJACENT STORAGE ROOM, REF MEP
OWNER PROVIDED BREAK ROOM EQUIPMENT INCLUDES BUT IS NOT LIMITED TO: (2) REFRIGERATORS, (2) MICROWAVES, COFFEE MACHINE, COMMERCIAL COFFEE GRINDER, TEA MACHINE AND ICE MACHINE; REF PLUMBING FOR REQUIRED WATER LINES AND FLOOR DRAINS AND ELECT FOR POWER REQUIREMENTS
OWNER PROVIDED ROOM SCHEDULER, REF TELECOM FOR CONTRACTOR INSTALLED INFRASTRUCTURE REQUIREMETS
BACK-LIT SIGNAGE BY OWNER, COORDINATE W/ OWNERS SIGNAGE PROVIDER FOR ELECTRICAL AND BLOCKING REQUIREMENTS
ESD FLOOR TILE REQUIRES GROUNDING, REF FINISH SCHEDULE AND ELECT.
SAW CUT FLOOR FOR FLOOR BOX AND CABELING AS REQUIRED, REF ELECT AND TELECOM
ACCESS CONTROL REQUIRED AT ELEVATOR TO RESTRICT ACCESS TO CERTAIN LEVELS. COORDINATE TRAVELING CABLE REQUIREMENTS WITH OWNERS ACCESS CONTROL PROVIDER.
REMOVE GWB WITH ORANGE PEEL TEXTURE AND REPLACE WITH NEW GWB, TYP.
CONCRETE FLOOR AND METAL DECK INFILL, REF STRUCT
ROOF DRAIN LEADER, REF PLUMBING
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
SHEET TITLE
PROJECT NUMBER
SHEET NUMBER
schwerdt design grouparchitecture interiors planning2231 sw wanamaker rd suite 303
A
B
C
D
54321
A
B
C
D
FILE
PA
TH:
DA
TE:
DR
AW
N B
Y:
54321
topeka, kansas 66614-4275phone: 785.273.7540fax: 785.273.7579
500 north broadway suite 200oklahoma city, ok 73102phone: 405.231.3105fax: 405.231.3115
SUBMISSION DATES
C:\U
sers
\Laure
n.S
DG
-SC
I\D
ocum
ents
\2019 0
9-1
6_190121 A
E P
rofe
ssio
nal B
uild
ing P
hase 1
Rem
odel_
Laure
n.r
vt
10/3
/2019 1
1:2
0:3
5 A
M
AD
VIS
OR
S E
XC
EL
-GA
GE
CE
NTE
R C
AM
PU
S
PH
AS
E 1
-B
UIL
DIN
G A
-R
EM
OD
EL
TOP
EK
A, K
AN
SA
S 6
6604
BUILDING A - SECONDFLOOR PLAN
190121
A-102
Aut
hor SCALE: 1/8" = 1'-0"
1BUILDING A - SECOND FLOOR PLAN N
PLAN LEGEND & NOTES
1
ADD-1, REV #1 10/02/2019
1 3 4 5 6 7 8 9
A
B
C
1.5 2
1
A-301
2
A-304
1' - 0" 1' - 0"
OPEN TO STRUCT
MOTHERS RM
A221
TRAINING
A222
WOMENS
A219MENS
A218A/V
A215
CONFERENCE
A213
MGR OFFICE
A216MGR OFFICE
A214HUDDLE
A212HUDDLE
A210HUDDLE
A208
COPY/PRINT
A207STAIR
AS2S
ELEV LOBBY
A204
ELEV
AE2
JAN
A203
OPEN TO STRUCT
BREAK ROOM
A209
OPEN OFFICE
A201ELEC
A217
OPEN TO STRUCT
LOUNGE
A220
STAIR
AS2N
TEAM
A211
CORR.
128
OPEN TO STRUCT
1
A-3022
A-302
2 x 2 ACT9' - 6"
GWB9' - 0"
2 x 2 ACT9' - 2"
2 x 2 ACT9' - 2"
GWB9' - 0"
GWB9' - 0"
2 x 2 ACT9' - 2"
1' -
0"
1' -
0"
1' -
0"
2 x 2 ACT9' - 2"
2 x 2 ACT9' - 0"
2 x 2 ACT9' - 0"
2 x 2 ACT9' - 0"
2 x 2 ACT9' - 0"
2 x 2 ACT9' - 0"
2 x 2 ACT9' - 0"
2 x 2 ACT9' - 0"
2 x 2 ACT9' - 0"
2 x 2 ACT9' - 6"
2 x 2 ACT8' - 0"
2 x 2 ACT8' - 0"2 x 2 ACT
8' - 6"
2 x 2 ACT8' - 0"
2 x 2 ACT9' - 4"
NO CEILING
2 x 2 ACT9' - 2"2 x 2 ACT
9' - 6"
OPEN OFFICE
A206
GWB9' - 0"
2
A-111
SIM
3
A-501
4' - 0"
2' - 7 1/2"
GWB9' - 0"
3
A-111
Sim
2 x 2 ACT9' - 6"GWB
9' - 4"2 x 2 ACT
9' - 6"
2 x 2 ACT9' - 6"
2 x 2 ACT10' - 0"
4
A-502
4
A-501
(ACM-2) SOFFIT, REF SECTIONS AND DETAILS
(ACM-2) SOFFIT, REF SECTIONS AND DETAILS
ROOF DRAIN TO CONNECT TO EXTERIOR DOWN LEADER, TYP.
HOLE IN SOFFIT FOR OVERFLOW, TYP.
13
A-501
1
2 X 2 ACOUSTIC CEILING TILE
2 X 4 ACOUSTIC CEILING TILE
GYP CEILING
RCP HATCH LEGEND
RCP SYMBOLD LEGEND
2 X 4 TROFFER LIGHT
2 X 2 TROFFER LIGHT
8" RECESSED CAN
8' - 0" ELEVATION
1. PREP AND PAINT EXPOSED EXISTING STRUCTURE.
2. NO CEILING WORK IN HATCHED AREA3. COORDINATE W/ OWNERS AV CONSULTANT
FOR ALL CEILING MOUNTED EQUIPMENT NOT SHOWN IN RCT; NOTIFY ARCHITECT OF ANY DISCREPANCIES.
4. INSTALL LIGHT FIXTURES AT THE CENTER OF THE ACOUSTICAL CEILING PANEL, UNO.
5. INSTALL SUSPENDED CEILING GRID TO BE LEVEL WITHIN A TOLERANCE OF 1/8" / 12'-0". ANCHOR AS REQUIRED.
6. ALL LIGHTING NOT SHOWN ON ARCHITECTURAL RCP, REFERENCE ELECTRICAL FOR ALL LIGHTING REQUIREMENTS; NOTIFY ARCHITECT OF ANY DISCREPANCIES.
RCP GENERAL PLAN NOTES
ACT - 1
ACT - 2
ACT - 3
GWB
4 X 4 ACOUSTIC CEILING CLOUDS
ACT - 4
4 X 4 ACOUSTIC CEILING CLOUDS COLOR - 1
ACT - 54 X 4 ACOUSTIC CEILING CLOUDSCOLOR - 2
ACT - 61'-11 X 5'-10" ACOUSTIC CEILING CLOUDS
SHEET TITLE
PROJECT NUMBER
SHEET NUMBER
schwerdt design grouparchitecture interiors planning2231 sw wanamaker rd suite 303
A
B
C
D
54321
A
B
C
D
FILE
PA
TH:
DA
TE:
DR
AW
N B
Y:
54321
topeka, kansas 66614-4275phone: 785.273.7540fax: 785.273.7579
500 north broadway suite 200oklahoma city, ok 73102phone: 405.231.3105fax: 405.231.3115
SUBMISSION DATES
C:\U
sers
\Laure
n.S
DG
-SC
I\D
ocum
ents
\2019 0
9-1
6_190121 A
E P
rofe
ssio
nal B
uild
ing P
hase 1
Rem
odel_
Laure
n.r
vt
10/3
/2019 1
1:2
0:3
6 A
M
AD
VIS
OR
S E
XC
EL
-GA
GE
CE
NTE
R C
AM
PU
S
PH
AS
E 1
-B
UIL
DIN
G A
-R
EM
OD
EL
TOP
EK
A, K
AN
SA
S 6
6604
REFLECTED CEILING PLAN- BUILDING A - SECOND
FLOOR
190121
A-112
Aut
hor
SCALE: 1/8" = 1'-0"1
REFLECTED CEILING PLAN - BUILDING A -SECOND FLOOR
N
REFLECTED CEILING LEGEND
TYP.
ADD-1, REV #1 10/02/2019
1 3 4 5 6 7 8 9
A
B
C
2
1
A-301
20' -
0"
20' -
0"
19' - 1 1/2" 20' - 0" 20' - 0" 20' - 0" 20' - 0" 20' - 0" 20' - 0" 19' - 1 1/2"
RTU - A1, REF MECH RTU - A2, REF MECH RTU - AL, REF MECH
31' -
8 1
/8"
3' - 0"
3' - 0"
TYP.6"
TY
P.
5"
3' -
0"
CURB, TYP.
3' - 0" 3' - 6" 3' - 0" 3' - 0" 3' - 0"
EXISTING HATCH TO REMAIN
SLO
PE
SLO
PE
SLOPE
PROVIDE WALKING PATHS TO EACH RTU, REF. SPEC
38' - 4 1/2"
INSTALL NEW 60 MIL TPO ROOF SYSTEM OVER MIN 5" TAPERED POLYISO INSULATION AND 1/2" HD COVER BOARD, R-30 MIN, REF. SPEC.
PROVIDE WALKING PATHS TO EACH RTU, REF. SPEC
PROVIDE WALKING PATHS TO EACH RTU, REF. SPEC
SLO
PE
LIMESTONE WING WALL
3' - 0"
3' -
0"
1
A-3022
A-302
STAIR BELOW
STAIR BELOW
TAPERED INSULATION CRICKET, TYP.
PRE-FINISHED METAL COPING, TYP.
EXHAUST FAN, REF MECH
EXHAUST FAN, REF MECH
ROOF HYDRANT, REF MEP
3
A-501
PRE-FINISHED METAL COPING, TYP.
A-501
12PRE-FIN METAL COPING OVER BRACING PARTITION
4
A-501
PRE-FIN METAL COPING OVER BRACING PARTITION
SLOPERDOVERFLOW
SCUPPER, PLACE 2" MIN ABOVE ROOF DRAIN LEVEL
RD/OD, TYP.
SLOPE SLOPESLOPE SLOPESLOPE SLOPESLOPE SLOPESLOPE SLOPESLOPE SLOPE
1/4"
/ F
T M
IN
1/4"
/ F
T M
IN
13
A-5011
TYP.
ROOF GENERAL PLAN NOTES:
1. CONTRACTOR TO VERIFY EXISTING SITE AND ROOF CONDITIONS.
2. R-VALUE MUST BE A MINIMUM OF 303. TAPER ROOF TOWARD NEW DRAINS ON
WEST SIDE OF BUILDING.4. REPLACE EXISTING RTU'S WITH NEW
UNITS, NEW RTU'S REQUIRE CURB, FLASHING AND MEMBRANE, REF. MEP, TYP.
SHEET TITLE
PROJECT NUMBER
SHEET NUMBER
schwerdt design grouparchitecture interiors planning2231 sw wanamaker rd suite 303
A
B
C
D
54321
A
B
C
D
FILE
PA
TH:
DA
TE:
DR
AW
N B
Y:
54321
topeka, kansas 66614-4275phone: 785.273.7540fax: 785.273.7579
500 north broadway suite 200oklahoma city, ok 73102phone: 405.231.3105fax: 405.231.3115
SUBMISSION DATES
C:\U
sers
\Laure
n.S
DG
-SC
I\D
ocum
ents
\2019 0
9-1
6_190121 A
E P
rofe
ssio
nal B
uild
ing P
hase 1
Rem
odel_
Laure
n.r
vt
10/3
/2019 1
1:2
0:3
8 A
M
AD
VIS
OR
S E
XC
EL
-GA
GE
CE
NTE
R C
AM
PU
S
PH
AS
E 1
-B
UIL
DIN
G A
-R
EM
OD
EL
TOP
EK
A, K
AN
SA
S 6
6604
ROOF PLAN - BUILDING A
190121
A-121
Aut
hor
SCALE: 1/8" = 1'-0"1
BUILDING A - ROOF PLAN N
ADD-1, REV #1 10/02/2019
SECOND FLOOR113' - 11"
B.O. DECK126' - 4"
ABC
RTU
SPLIT FACE STONE WING WALL
BACK LIT SIGNAGE BY OWNER, REF. ELECTRICAL
H I H
SPLIT FACE STONE WING WALL
NEW ROOF TOP UNITREF: MEP
ALUMUNUM COMPOSITE METAL PANEL (ACM - 3)
3
A-501
6"
EQ EQ EQ EQ5' - 0" 5' - 0" 5' - 0" 5' - 0" EQ EQ EQ EQ EQ4' - 11 1/8" 4' - 11 1/8"
ALUMINUM COMPOSITE METAL PANEL (ACM - 2)
PRE FINISHED METAL COPING TO MATCH ACM - 2ALUMINUM STOREFRONT, REF FRAME ELEVATIONS, TYP.
EXISTING FACE BRICK
EXISTING STEEL CANOPY, PAINT TO MATCH ACM - 3
4
A-501
SIM
STONE COPING
SECOND FLOOR113' - 11"
B.O. DECK126' - 4"
FIRST FLOORLEVEL - SOUTH
102' - 0"
A B C
FIRST FLOORLEVEL - EAST
ENTRY100' - 0"
20' - 0" 19' - 4" 8" 31' - 8"
31' -
2"
RTU
SPLIT FACE STONE WING WALL
BACK LIT SIGNAFE BY OWNER, REF. ELECTRICAL
ON
ACM PANEL - 3
SPLIT FACE STONE WING WALL
NEW ROOF TOP UNITREF: MEP
4' -
6"
SCUPPER
ALUM STOREFRONT
EQ EQ EQ 5' - 0" 5' - 0" EQ EQ 5' - 0" 5' - 0" EQ EQ EQ EQ EQ EQ
6"
ALUMINUM COMPOSITE METAL PANEL (ACM - 2)
PRE FINISHED METAL COPING TO MATCH ACM - 2
ALUMINUM STOREFRONT, REF FRAME ELEVATIONS, TYP.
EXISTING STEEL CANOPY, PAINT TO MATCH ACM - 3
EXISTING FACE BRICK
ILLUMINATED BOLLARD, REF ELECT
4
A-501
3
A-501
SIM
FIRST FLOORLEVEL - NORTH
98' - 0"
SECOND FLOOR113' - 11"
B.O. DECK126' - 4"
1 3 4 5 6 7 8 9
FIRST FLOORLEVEL - SOUTH102' - 0"
1.5
FIRST FLOORLEVEL - EAST
ENTRY100' - 0"
2
1
A-301
1
A-302
2
A-302
2
A-301
SPLIT FACE STONE WING WALL
BACK LIT SIGNAGE, COORDINATE W/ OWNERS SIGNAGE MFGR; REF. ELECTRICAL
SPLIT FACE STONE WING WALL
BACK LIT SIGNAGE BY OWNER, REF. ELECTRICAL
RTU RTU RTU
ACM PANEL - 1
ACM PANEL - 2
A B B C
E
BB G
P Q Q Q QQ R
PAINT EXISTING CANOPIES TO REMAIN
STOREFRONT, TYP.
ACM PANEL - 1
Q
STONE COPING
PRE-FIN METAL COPING TO MATCH ACM-2
ALUMIMUM COMPOSITE METAL PANEL (ACM - 3)
STONE COPING
EXISTING CANOPY STRUTURE TO REMAIN, PAINT TO MATCH ACM-3
ILLUMINATED BOLLARD, REF ELEC; TYP.
FACE STONE
STONE COPING
B.O. DECK126' - 4"
13456789
FIRST FLOORLEVEL - SOUTH
102' - 0"
1.52
8' - 4"
8' - 4"
2
A-301
RTU RTU RTU
SPLIT FACE STONE
18' -
8"
J K
L JM
UTTTTT TS
3' -
0"
1' -
6"
STONE COPING
EXISTING CANOPY STRUCTURE TO REMAIN, PAINT TO MATCH ACM-3
RETAINING WALL, REF CIVIL SITE PACKAGE
TRANSFORMER, REF MEP
EXISTING CONCRETE WINDOW WELL, APPLY EIFS PARGE COAT TO OUTSTIDE, TYP.
PREP AND PAINT EXISTING STEEL
APPLY EIFS PARGE COAT
PRE-FIN METAL COPING TO MATCH ACM-2
ALUMINUM COMPOSTIE METAL PANEL (ACM - 2)
ALUMINUM COMPOSTIE METAL PANEL (ACM - 1)
EXISTING FACE BRICK
ALUMINUM STOREFRONT, TYP.
STONE COPING
FACE STONE
EXISTING CANOPY STRUCTURE, PAINT TO MATCH ACM-3
REPLACE EXISTING DOWNSPOUTS, TYP.
13
A-501
17' -
4"
TYP.
1
2
A-301
SIM
1
SHEET TITLE
PROJECT NUMBER
SHEET NUMBER
schwerdt design grouparchitecture interiors planning2231 sw wanamaker rd suite 303
A
B
C
D
54321
A
B
C
D
FILE
PA
TH:
DA
TE:
DR
AW
N B
Y:
54321
topeka, kansas 66614-4275phone: 785.273.7540fax: 785.273.7579
500 north broadway suite 200oklahoma city, ok 73102phone: 405.231.3105fax: 405.231.3115
SUBMISSION DATES
C:\U
sers
\Laure
n.S
DG
-SC
I\D
ocum
ents
\2019 0
9-1
6_190121 A
E P
rofe
ssio
nal B
uild
ing P
hase 1
Rem
odel_
Laure
n.r
vt
10/3
/2019 1
1:2
0:4
3 A
M
AD
VIS
OR
S E
XC
EL
-GA
GE
CE
NTE
R C
AM
PU
S
PH
AS
E 1
-B
UIL
DIN
G A
-R
EM
OD
EL
TOP
EK
A, K
AN
SA
S 6
6604
EXTERIOR ELEVATIONS -BUILDING A
190121
A-201
Aut
hor
SCALE: 1/8" = 1'-0"1
NORTH ELEVATIONSCALE: 1/8" = 1'-0"
2SOUTH ELEVATION
SCALE: 1/8" = 1'-0"4
East Elevation
SCALE: 1/8" = 1'-0"3
WEST ELEVATION
ADD-1, REV #1 10/02/2019
FIRST FLOORLEVEL - NORTH
98' - 0"
SECOND FLOOR113' - 11"
B.O. DECK126' - 4"
FIRST FLOORLEVEL - EAST
ENTRY100' - 0"
4 1/2"
1' -
11"
9"
9 1/2"
8"
MI N
.
1' - 4"
8' - 2 3/4"
8"
5 1
/2"
4"
B.O.S. 122' - 2 1/4"
12' -
0"
STONE COPING
FACE STONE
BACK-LIT SIGNAGE, COORDINATE WITH OWNER SIGNAGE PROVIDER, REF ELECT
STONE WALL BRACING, REF STRUCT; REF DETAILS FOR STUD, SHEATHING, FLASHING AND COPING REQUIREMENTS
12 (MIN)
3 5/8" X 1 5/8" X 20 GA METAL STUD BRACING @ 16" O.C.
12"
MA
X
A-501
7
A-501
8
A-501
11
A-501
5
(ACM -2) TYP METAL WALL PANEL ASSEMBLY
8' - 1"
(ACM-2) TYP METAL SOFFIT ASSEMBLY
(ACM -1) TYP METAL WALL PANEL ASSEMBLY
PRE-FIN METAL FLASHING TO MATCH ACM
STEEL LINTEL, REF STRUCT
WINDOW ROLLER SHADE, TYP.
ALUMINUM STOREFRONT, TYP.
(ACM-1) METAL PANEL COLUMN WRAP BEYOND, REF DETAILS
WOOD SILL, TYP; REF DETAILS
(ACM-1) TYP METAL WALL PANEL ASSEMBLY ON EXISTING CMU
DECORATIVE ROOF ROCK
PRE-FIN METAL COPING TO MATCH ACM, SLOPE 1/4" PER FT. MIN, TYP.
PRE-FIN METAL COPING TO MATCH ACM
(ACM-3) TYP METAL SOFFIT PANEL ASSEMBLIES
STEEL BEAM AND ANGLE SUPPORTS, REF STRUCT
VESTIBULE
A101LOBBY
A102
OPEN OFFICE
A201
CEILING, REF RCP
REINFORCED CONCRETE SLAB ON GRADE, DOWEL INTO EXISTING FOUNDATION; REF STRUCT
DECORATIVE CONCRETE SLAB ON GRADE, REF CIVIL FOR ELEVATIONS
LOWER LEVEL
A002
A-501
1
A-501
9
(ACM-3) METAL WALL PANEL ASSEMBY W/ 6" CFMF
CONCRETE FOOTING, REF STRUCT
WALL ASSEMBLIES:
(SC1) TYP STONE CLAD ASSEMBLY:• FULL DEPTH STONE• BRACING & CLIPS TO SHEATHING AS REQUIRED BY INSTALLER• 1" NOM AIR GAP• CONTINUOUS FLUID-APPLIED MOISTURE BARRIER• 5/8" GYPSUM SHEATHING• 6" CFM STUD FRAMING (18 GA, MIN) @ 16 O.C.
(ACM) TYP METAL WALL PANEL ASSEMBLY: NUMBER AFTER DESIGNATES FINISH, REF SPEC• ALUMINUM COMPOSITE METAL PANEL W/ EXTRUSIONS AND CLIPS PER MFR• 2" POLYSIO INSULATION• CONTINUOUS FLUID APPLIED MOISTURE BARRIER• 5/8" GYPSUM SHEATHING• 3 5/8" CFM STUD FRAMING (18 GA, MIN.) W/ FIBERGLASS BATT INSULATION;
7/8" FURRING CHANNELS AT EXISTING CMU LOCATIONS; U.N.O
(OS) TYP METAL SOFFIT PANEL ASSEMBLY• ALUMINUM COMPOSITE METAL PANEL W/ EXTRUSTIONS AND CLIPS PER MFR• 2" POLYISO INSULATION• CONTINUOUS FLUID APPLIED MOISTURE BARRIER• 5/8" GYPSUM SHEATHING• FURRING CHANNELS OR 3 5/8" METAL STUD FRAMING, REF DETAILS
FIRST FLOORLEVEL - NORTH
98' - 0"
SECOND FLOOR113' - 11"
B
FIRST FLOORLEVEL - EAST
ENTRY100' - 0"
18' -
8"
4"
MIN.1"
1/2" COMPRESSIBLE FILLER
REINFORCED CONCRETE SIDEWALK, REF CIVIL FOR GRADES
REINFORCED CONCRETE FOOTING, REF STRUCT
FULL DEPTH STONE W/ BRACING AND CLIPS AS REQUIRED BY MFR
6" CFM FRAMING @ 16" O.C.
EXISTING CANOPY STRUCTURE, PAINT TO MATCH ACM-3
HSS 12X10X5/16 REF STRUCT
STONE COPING, SLOPE 1/4" PER FT
EXISTING 12" CANOPY COLUMN ENCLOSED IN NEW WALL
1
SHEET TITLE
PROJECT NUMBER
SHEET NUMBER
schwerdt design grouparchitecture interiors planning2231 sw wanamaker rd suite 303
A
B
C
D
54321
A
B
C
D
FILE
PA
TH:
DA
TE:
DR
AW
N B
Y:
54321
topeka, kansas 66614-4275phone: 785.273.7540fax: 785.273.7579
500 north broadway suite 200oklahoma city, ok 73102phone: 405.231.3105fax: 405.231.3115
SUBMISSION DATES
C:\U
sers
\Laure
n.S
DG
-SC
I\D
ocum
ents
\2019 0
9-1
6_190121 A
E P
rofe
ssio
nal B
uild
ing P
hase 1
Rem
odel_
Laure
n.r
vt
10/3
/2019 1
1:2
0:4
4 A
M
AD
VIS
OR
S E
XC
EL
-GA
GE
CE
NTE
R C
AM
PU
S
PH
AS
E 1
-B
UIL
DIN
G A
-R
EM
OD
EL
TOP
EK
A, K
AN
SA
S 6
6604
WALL SECTIONS -BUILDING A
190121
A-301
Aut
hor
SCALE: 1/2" = 1'-0"1
BUILDING A - EAST ENTRYSCALE: 1/2" = 1'-0"
2BUILDING A - SMALL FIN
ADD-1, REV #1 10/02/2019
5
8"
6"
8"
9" 9"
1' - 6"
6 3/4"
5/8" GWB ON 3 5/8" METAL STUD FRAMING
EXISTING STEEL COLUMN
ALUMINUM STOREFRONT, SEALANT BOTH SIDES, TYP.
2X BLOCKING AND/OR SHIMS AS REQUIRED
ALUMINUM COMPOSITE METAL PANEL (ACM - 1)
2" POLYISO INSULATION
FLUID APPLIED MOISTURE BARRIER OVER GYP SHEATHING
ROOF DRAIN LEADER, REF PLUMBING
TOP OF WALL EL: 129' - 4"
PREFINISHED METAL COPING TO MACTH ACM, SLOPE 1/4" PER FT MIN.
PRE TREATED 2X BLOCKING AND PLYWOOD PARAPET FRAMING
EXTEND ROOF MEMBRANE OVER TOP OF PARAPET WALL
• PREFINISHED (ACM PANEL - 1)• 3" RIGID INSULATION• FLUID VAPOR AIR BARRIER• 5/8" GYP. BOARD SHEATHING• 6" MTL. STUD W/ BATT. INSULATION• 5/8" GYP. BOARD PARAPET SHEATHING• 60 MIL TPO TO WRAP UP PARAPET
B.O. DECK126' - 4"
SIMPSON FCB43.5 @ EA STUD
STEEL BEAM AND CHANNEL, REF STRUCT
ALUMINUM COMPOSITE METAL PANEL W/ 2" POLYISO INSULATION AND FLUID APPLIED
MOISTURE BARRIER OVER GYP SHEATHING
3 5/8" x 1 5/8" x 20GA METAL STUD FRAMING @ 16" O.C.
FIBERGLASS BATT INSULATION
ACM SOFFIT PANEL
1/2" FURRING STRIPS AS REQUIRED TO FASTEN METAL PANEL
F.V. LOCATION OF BRICK WALL BEYOND, ACM PANEL TO EXTEND PAST BRICK WALL
1' -
1"
6"
B.O. DECK126' - 4"
3/8" STIFFENER
SIMPSON FCB43.5 @ EA BRACE
3 5/8" X 1 5/8" X 20GA METAL STUD BRACING @ 16" O.C.
STEEL BEAM, REF STRUCT
ALUMINUM COMPOSITE METAL WALL AND
SOFFIT PANEL (ACM-2)
2" POLYISO INSULATION
FLUID-APPLIED MOISTURE BARRIER
5/8" GYP WALL SHEATHING
3 5/8" METAL STUD FRAMING W/ FIBERGALSS
BATT INSULATION
VAPOR BARRIER ON GYP ROOF SHEATHING
EXISTING STRUCTURE INDICATED BY GREY
POCHE, TYP.
STEEL ANGLE WELDED AT EA JOIST, REF STRUCT
WALL SECTIONS
VARIES, REF
• PREFINISHED (ACM PANEL - 1)• 3" RIGID INSULATION• FLUID VAPOR AIR BARRIER• 5/8" GYP. BOARD SHEATHING
ALUMINUM STOREFRONT
PREFINISHED METAL FLASHING TO MATCH ACM
WINDOW ROLLER SHADE
B.O.S. 122' - 2 1/4"
STEEL LINTEL, REF STRUCT
3 5/8" METAL STUD FRAMING W/ FIBERGLASS BATT INSULATION
2X BLOCKING AS REQUIRED
7 1/2"ALUMINUM STOREFRONT
PREFINISHED METAL FLASHING TO MATCH ACM - 1
PREFINISHED METAL PANEL (ACM PANEL - 1)
2" RIGID INSULATION
1 1
/2"3
/4"
3/4"
WOOD SILL; TYP. ALL WINDOWS
5/8" GYP SHEATHING
7/8" FURRING HAT CHANNEL
EXISTING CMU
FLUID-APPLIED MOISTURE BARRIER
B.O. DECK126' - 4"
9
6"
ALUMINUM STOREFRONT
SEALANT, TYP.
SPANDREL PANEL, REF FRAME ELEVATIONS
5/8" GWB ON 3 5/8" METAL FRAMING
ACOUSTIC CEILING TILE, REF RCP
WINDOW ROLLER SHADE
1' -
6"
3' -
0"
12 (MIN)
3 5/8" x 1 5/8" x 20GA METAL STUD BRACING @ 16" O.C.
GYP ROOF SHEATHING
PRE-FIN METAL COPING TO MATCH ACM-2
EXTEND ROOF MEMBRANE OVER TOP OF PARAPET WALL
ALUMINUM COMPOSITE METAL PANEL (ACM - 2), ALIGN WITH PANELS BEYOND AT BRICK
2" POLYISO INSULATION
1/4" / 1'-0 MIN
FLUID APPLIED MOISTURE BARRIER
GYP SHEATHING
3 5/8" x 1 5/8" x 20GA METAL STUD FRAMING @ 16" O.C.
FIBERGLASS BATT INSULATION
SEALANT
2 X 8 HEADER2"
PRE-FINISHED METAL CLOSURE TRIM TO MATCH STOREFRONT
EXISTING FACE BRICK BEYOND
1 1/2" RIGID POLYISO INSULATION
FILL CAVITY W/ UNFACED BATT INSULATION
TPO ROOF MEMBRANE
METAL SILL BELOW
ALUMINUM STOREFRONT
WOOD SILL BELOW
BREAK METAL END CAP TO MATCH STOREFRONT, PUSHED
TIGHT AGAINST GLAZING
FILL WALL CAP WITH FIBERGLASS BATT INSULATION
EXISTING PARTITION
6
C
PRE- FIN FLASHING TO WRAP CORNER, 2" MIN
COUNTERFLASHING SET IN REGLET, SET IN SEALANT; PROVIDE COPING ABOVE TO COVER OVER FLASHING
TPO ROOF MEMBRANE TO TERM AT TERM BAR
SEALANT
HSS STEEL BRACING, REF STRUCT
HSS STEEL COLUMN, REF STRUCT
TPO MEMBRANE ADHERED TO GYP
SHEATHING ON 3 5/8" MTL STUD FRAMING
FACE STONE, 1" NOM AIR GAP, FLUID APPLIED MOISTURE BARRIER
ON GYP SHEATHING ON 6" CFMF
STONE TIE, TYP.
SEALANT REQUIRED AT TPO TO FLASHING
JOINT, TYP.
1
B.O. DECK126' - 4"
1
1' -
6"
3' -
0"
EXISTING FACE BRICK WALL
5/8" GWB ON 2 1/2" METAL STUD FURRING W/ BATT
INSULATION, TYP. ON EXTERIOR WALLS
12 (MIN)
3 5/8" x 1 5/8" x 20GA METAL STUD BRACING @ 16" O.C.
GYP ROOF SHEATHING
TPO MEMBRANE
PRE-FIN METAL COPING TO MATCH ACM-2
EXTEND ROOF MEMBRANE OVER TOP OF PARAPET WALL
ALUMINUM COMPOSITE METAL PANEL (ACM - 2)
2" POLYISO INSULATION
1/4" / 1'-0 MIN
FLUID APPLIED MOISTURE BARRIER
GYP SHEATHING
3 5/8" x 1 5/8" x 20GA METAL STUD FRAMING @ 16" O.C.
FIBERGLASS BATT INSULATION
SEALANT
FILL CAVITY W/ UNFACED BATT INSULATION
SECOND FLOOR113' - 11"
8"
MI N
.
FLEXIBLE FLASHING W/ TERM BAR, CAULK TOP OF BAR
(ACM - 1) METAL PANEL ASSEMBLY W/ 7/8" FURRING STRIPS ON EXISTING CMU
PRE-FIN METAL FLASHING W/ REGLET SET UNDER METAL PANEL
CONTINUOUS FLUID-APPLIED MOISTURE BARRIER
COUNTERFLASHING
WRAP TPO UP FACE OF WALL & TERM AT TERM BAR UNDER COUNTERFLASHING
2" OF DECORATIVE ROCK
METAL DECK, REF STRUCT
5" POLYISO ROOF INSULATION
STEEL BEAM, REF STRUCT
B.O. DECK126' - 4"
3 5/8" X 1 5/8" X 20 GA METAL STUD BRACING @ 16" O.C.
(ACM -2) TYP METAL WALL PANEL ASSEMBLY
PRE-FIN METAL COPING TO MATCH ACM, SLOPE 1/4" PER FT. MIN, TYP.
FACE OF TPO ROOF MEMBRANE BEYOND
BRICK WALL BEYOND
F.V. EDGE OF
3X3X3/8 STEEL ANGLE DECK SUPPORT
1 1/2" METAL DECK , FASTEN TO EXISTING DECK
SIMPSON FCB43.5 @ EA STUD
3 5/8" x 1 5/8" x 20GA METAL STUD FRAMING @ 16" O.C.
STEEL BEAM AND CHANNELS, REF STRUCT
ROOF DRAIN
1/4" PER FT SLOPED INSULATION
ROOF DRAIN LEADER
SHEET TITLE
PROJECT NUMBER
SHEET NUMBER
schwerdt design grouparchitecture interiors planning2231 sw wanamaker rd suite 303
A
B
C
D
54321
A
B
C
D
FILE
PA
TH:
DA
TE:
DR
AW
N B
Y:
54321
topeka, kansas 66614-4275phone: 785.273.7540fax: 785.273.7579
500 north broadway suite 200oklahoma city, ok 73102phone: 405.231.3105fax: 405.231.3115
SUBMISSION DATES
C:\U
sers
\Laure
n.S
DG
-SC
I\D
ocum
ents
\2019 0
9-1
6_190121 A
E P
rofe
ssio
nal B
uild
ing P
hase 1
Rem
odel_
Laure
n.r
vt
10/3
/2019 1
1:2
0:4
6 A
M
AD
VIS
OR
S E
XC
EL
-GA
GE
CE
NTE
R C
AM
PU
S
PH
AS
E 1
-B
UIL
DIN
G A
-R
EM
OD
EL
TOP
EK
A, K
AN
SA
S 6
6604
BUILDING A - DETAILS
190121
A-501
Aut
hor
SCALE: 1 1/2" = 1'-0"2
BUILDING A - VESTIBULE DETAIL
SCALE: 1 1/2" = 1'-0"11
BUILDING A - PARAPET CAP
SCALE: 1 1/2" = 1'-0"8
ACM SOFFIT OUTSIDE CORNERSCALE: 1 1/2" = 1'-0"
7ACM SOFFIT INSIDE CORNER
SCALE: 1 1/2" = 1'-0"5
ACM AT STOREFRONT HEAD
SCALE: 1 1/2" = 1'-0"1
ACM AT STOREFRONT SILLSCALE: 1 1/2" = 1'-0"
3ROOF AT N/S STOREFRONT
SCALE: 1 1/2" = 1'-0"6
EXISTING WALL AT SF
SCALE: 1 1/2" = 1'-0"12
STONE WALL BRACING AT ROOF
SCALE: 1 1/2" = 1'-0"4
ACM AT BRICK
SCALE: 1 1/2" = 1'-0"9
WALL TO LOW ROOF TRANSITION
SCALE: 1 1/2" = 1'-0"13
PARAPET AT ROOF DRAIN
1
ADD-1, REV #1 10/02/2019
SHEET TITLE
PROJECT NUMBER
SHEET NUMBER
schwerdt design grouparchitecture interiors planning
2231 sw wanamaker rd suite 303
A
B
C
D
54321
A
B
C
D
54321
topeka, kansas 66614-4275phone: 785.273.7540fax: 785.273.7579500 north broadway suite 200oklahoma city, ok 73102phone: 405.231.3105fax: 405.231.3115
SUBMISSION DATES
09-19-19
3639 SW Summerfield Drive, Suite A
Telephone: (785) 233-3232
Latimer Sommers& Associates, P.A.
C O N S U L T I N G E N G I N E E R S
Topeka, Kansas 66614-3974
FAX: (785) 233-0647Email: [email protected]
LSA PROJECT NO. 1908004
190121
AD
VIS
OR
S E
XC
EL
- G
AG
E C
EN
TE
R C
AM
PU
S
PH
AS
E 1
- B
UIL
DIN
G A
- R
EM
OD
EL
TO
PE
KA
, K
AN
SA
S 6
66
04
ELECTRICAL SCHEDULES -
BUILDING A
E-409
UP
UP
DN
DN
1 3 4 5 6 7 8 9
A
B
C
1.5 2
WINDOW WELL WINDOW WELL
WINDOW WELL
FOUNDERS
OFFICE
A124
JAN
A123
TR
AN
SF
OR
ME
R
LOBBY
A102
RECEPTION
A104
WAITING
A103
STORAGE
A113
IT
A112
TRAFFIC
STORAGE
A114
MENS
A118
WOMENS
A117
FOCUS
A108
OPEN OFFICE
A109
TRAFFIC
A110
VESTIBULE
A101
HUDDLE
A106
CONFERENCE
A105
CORRIDOR
A107
BREAK
A111
RAMP
A115
CORRIDOR
A116
OPEN OFFICE
A119
RAMP
A121
OPEN OFFICE
A122
ELEV LOBBY
A125
STAIR
AS1S
ELEV
AE1
STAIR
AS1N
TR
AS
H E
NC
LO
SU
RE
WINDOW WELL
STORAGE
IT
A112
BREAK
SHEET TITLE
PROJECT NUMBER
SHEET NUMBER
schwerdt design grouparchitecture interiors planning
2231 sw wanamaker rd suite 303
A
B
C
D
54321
A
B
C
D
54321
topeka, kansas 66614-4275phone: 785.273.7540fax: 785.273.7579500 north broadway suite 200oklahoma city, ok 73102phone: 405.231.3105fax: 405.231.3115
SUBMISSION DATES
09-19-19
3639 SW Summerfield Drive, Suite A
Telephone: (785) 233-3232
Latimer Sommers& Associates, P.A.
C O N S U L T I N G E N G I N E E R S
Topeka, Kansas 66614-3974
FAX: (785) 233-0647Email: [email protected]
LSA PROJECT NO. 1908004
190121
AD
VIS
OR
S E
XC
EL
- G
AG
E C
EN
TE
R C
AM
PU
S
PH
AS
E 1
- B
UIL
DIN
G A
- R
EM
OD
EL
TO
PE
KA
, K
AN
SA
S 6
66
04
FIRST FLOOR PLAN -
BUILDING A - TELECOM
T-102
2 TELECOM1/4"=1'-0"FLOOR PLAN - BUILDING A
.
PARTIAL FIRST
1 TELECOM1/8"=1'-0"FIRST FLOOR PLAN - BUILDING A
NORTH
DN
DN
1 3 4 5 6 7 8 9
A
B
C
1.5 2
A/V
A215
MENS
A218
WOMENS
A219
MOTHERS RM
A221
TRAINING
A222
LOUNGE
A220
MGR OFFICE
A216
CONFERENCE
A213
BREAK ROOM
A209 TEAM
A211
ELEV
AE2
JAN
A203
ELEV LOBBY
A204
STAIR
AS2S
ELEC
A205
COPY/PRINT
A207
HUDDLE
A208
HUDDLE
A210
HUDDLE
A212
MRG OFFICE
A214
STAIR
AS2N
OPEN OFFICE
A201
OPEN OFFICE
A206
ELEC
A217
1 TELECOM1/8"=1'-0"SECOND FLOOR PLAN - BUILDING A
NORTH
SHEET TITLE
PROJECT NUMBER
SHEET NUMBER
schwerdt design grouparchitecture interiors planning
2231 sw wanamaker rd suite 303
A
B
C
D
54321
A
B
C
D
54321
topeka, kansas 66614-4275phone: 785.273.7540fax: 785.273.7579500 north broadway suite 200oklahoma city, ok 73102phone: 405.231.3105fax: 405.231.3115
SUBMISSION DATES
09-19-19
3639 SW Summerfield Drive, Suite A
Telephone: (785) 233-3232
Latimer Sommers& Associates, P.A.
C O N S U L T I N G E N G I N E E R S
Topeka, Kansas 66614-3974
FAX: (785) 233-0647Email: [email protected]
LSA PROJECT NO. 1908004
190121
AD
VIS
OR
S E
XC
EL
- G
AG
E C
EN
TE
R C
AM
PU
S
PH
AS
E 1
- B
UIL
DIN
G A
- R
EM
OD
EL
TO
PE
KA
, K
AN
SA
S 6
66
04
SECOND FLOOR PLAN -
BUILDING A - TELECOM
T-103
UP
UP
DN
DN
1 3 4 5 6 7 8 9
A
B
C
1.5 2
WINDOW WELL WINDOW WELL
WINDOW WELL
FOUNDERS
OFFICE
A124
JAN
A123
TR
AN
SF
OR
ME
R
LOBBY
A102
RECEPTION
A104
WAITING
A103
STORAGE
A113
IT
A112
TRAFFIC
STORAGE
A114
MENS
A118
WOMENS
A117
FOCUS
A108
OPEN OFFICE
A109
TRAFFIC
A110
VESTIBULE
A101
HUDDLE
A106
CONFERENCE
A105
CORRIDOR
A107
BREAK
A111
RAMP
A115
CORRIDOR
A116
OPEN OFFICE
A119
RAMP
A121
OPEN OFFICE
A122
ELEV LOBBY
A125
STAIR
AS1S
ELEV
AE1
STAIR
AS1N
TR
AS
H E
NC
LO
SU
RE
A125.2
A125.1
A105
A1
06
A1
01
.2
A1
01
.1
A1
12
A1
13
A1
14
A1
17
A1
18
10
8
19
6
A1
24
A1
23
AS1N
AS
1S
A1
22
A110
A111
AE1
SHEET TITLE
PROJECT NUMBER
SHEET NUMBER
schwerdt design grouparchitecture interiors planning
2231 sw wanamaker rd suite 303
A
B
C
D
54321
A
B
C
D
54321
topeka, kansas 66614-4275phone: 785.273.7540fax: 785.273.7579500 north broadway suite 200oklahoma city, ok 73102phone: 405.231.3105fax: 405.231.3115
SUBMISSION DATES
09-19-19
3639 SW Summerfield Drive, Suite A
Telephone: (785) 233-3232
Latimer Sommers& Associates, P.A.
C O N S U L T I N G E N G I N E E R S
Topeka, Kansas 66614-3974
FAX: (785) 233-0647Email: [email protected]
LSA PROJECT NO. 1908004
190121
AD
VIS
OR
S E
XC
EL
- G
AG
E C
EN
TE
R C
AM
PU
S
PH
AS
E 1
- B
UIL
DIN
G A
- R
EM
OD
EL
TO
PE
KA
, K
AN
SA
S 6
66
04
FIRST FLOOR PLAN -
BUILDING A - SECURITY
T-202
1 SECURITY1/8"=1'-0"FIRST FLOOR PLAN - BUILDING A
NORTH
DN
DN
1 3 4 5 6 7 8 9
A
B
C
1.5 2
A/V
A215
MENS
A218
WOMENS
A219
MOTHERS RM
A221
TRAINING
A222
LOUNGE
A220
MGR OFFICE
A216
CONFERENCE
A213
BREAK ROOM
A209 TEAM
A211
ELEV
AE2
JAN
A203
ELEV LOBBY
A204
STAIR
AS2S
ELEC
A205
COPY/PRINT
A207
HUDDLE
A208
HUDDLE
A210
HUDDLE
A212
MRG OFFICE
A214
STAIR
AS2N
OPEN OFFICE
A201
OPEN OFFICE
A206
ELEC
A217
1 SECURITY1/8"=1'-0"SECOND FLOOR PLAN - BUILDING A
NORTH
A2
07
A219
A2
18
A222
A221
A221.1
A221.2
A2
21
.3
AS
2S
A2
17
A2
09
A2
13
A220
A201
A2
16
A2
15
AS2N
A205
A203
SHEET TITLE
PROJECT NUMBER
SHEET NUMBER
schwerdt design grouparchitecture interiors planning
2231 sw wanamaker rd suite 303
A
B
C
D
54321
A
B
C
D
54321
topeka, kansas 66614-4275phone: 785.273.7540fax: 785.273.7579500 north broadway suite 200oklahoma city, ok 73102phone: 405.231.3105fax: 405.231.3115
SUBMISSION DATES
09-19-19
3639 SW Summerfield Drive, Suite A
Telephone: (785) 233-3232
Latimer Sommers& Associates, P.A.
C O N S U L T I N G E N G I N E E R S
Topeka, Kansas 66614-3974
FAX: (785) 233-0647Email: [email protected]
LSA PROJECT NO. 1908004
190121
AD
VIS
OR
S E
XC
EL
- G
AG
E C
EN
TE
R C
AM
PU
S
PH
AS
E 1
- B
UIL
DIN
G A
- R
EM
OD
EL
TO
PE
KA
, K
AN
SA
S 6
66
04
SECOND FLOOR PLAN -
BUILDING A - SECURITY
T-203