ATC-5000NG ATC/DME Test Set Getting Started Manual EXPORT CONTROL WARNING: This document contains controlled technical data under the jurisdiction of the Export Administration Regulations (EAR), 15 CFR 730-774. It cannot be transferred to any foreign third party without the specific prior approval of the U.S. Department of Commerce, Bureau of Industry and Security (BIS). Violations of these regulations are punishable by fine, imprisonment, or both. Issue-4

SECTION 2 - OPERATION

  • Upload
    others

  • View
    3

  • Download
    0

Embed Size (px)

Citation preview

Page 1: SECTION 2 - OPERATION

ATC-5000NG

ATC/DME Test Set

Getting Started Manual

EXPORT CONTROL WARNING: This document contains controlled technical data under the jurisdiction of the Export Administration Regulations (EAR), 15 CFR 730-774. It cannot be transferred to any foreign third party without the specific prior approval of the U.S. Department of Commerce, Bureau of Industry and Security (BIS). Violations of these regulations are punishable by fine, imprisonment, or both.

Issue-4

Page 2: SECTION 2 - OPERATION

ATC -5000NG Get t ing S ta r ted M anua l

Subject to Export Control, see Cover Page for detai ls.

ATC-5000NG

ATC/DME Test Set

Getting Started Manual

PUBLISHED BY Aerof lex

COPYRIGHT Aerof lex 2017

All r ights reserved. No part of this publ icat ion may be reproduced, stored in a retrieval system, or transmitted in any form or by any means, electronic , mechanical, photocopying, recording or otherwise without the prior permission of the publisher.

Original June 2015 Issue-2 August 2015 Issue-3 March 2016 Issue-4 June 2017

10200 West York / W ichita, Kansas 67215 U.S.A. / (316) 522 -4981 / FAX (316) 529-5330

Page 3: SECTION 2 - OPERATION

ATC -5000NG Get t ing S ta r ted M anua l

Subject to Export Control, see Cover Page for detai ls.

This manual contains essential information relat ing to init ial use of the Unit . Aerof lex recommends the operator become famil iar with the

Operat ion Manual contained on the accompanying CD-ROM.

Aerof lex updates Test Set software on a rout ine basis. As a result , the examples may show images from earl ier software versions. Images are

updated when appropriate.

Page 4: SECTION 2 - OPERATION

ATC -5000NG Get t ing S ta r ted M anua l

Subject to Export Control, see Cover Page for detai ls.

1

Product Warranty

Refer to http:/ /ats.aerof lex.com/warranty for the Product Warranty information.

Electromagnetic Compatibil ity

Double shielded and properly terminated external interface cables must be used with this equipment when interfacing with the REMOTE Connector.

For cont inued EMC compliance, al l external cables must be shielded and 3 meters or less in length.

Nomenclature Statement

In this manual, ATC-5000NG, Test Set or Unit refers to the ATC-5000NG ATC/DME Test Set .

Declaration of Conformity

The Declarat ion of Conformity Cert i f icate included with the Unit should remain with the Unit .

Aerof lex recommends the operator reproduce a copy of the Declarat ion of Conformity Cert i f icate to be stored with the Operat ion Manual for future reference.

Software Version

Aerof lex updates Test Set software on a rout ine basis. As a result , examples may show images from earl ier software versions. Images are updated when appropriate.

Page 5: SECTION 2 - OPERATION

ATC -5000NG Get t ing S ta r ted M anua l

Subject to Export Control, see Cover Page for detai ls.

2

Precautions

SAFETY FIRST - TO ALL OPERATIONS PERSONNEL

General Conditions of Use

This product is designed and tested to comply with the requirements of IEC/EN61010-1 ‘Safety requirements for electrical equipment for measurement, control and laboratory use’ for Class I portable equipment and is for use in a pollut ion degree 2 environment. The equipment is designed to operate from instal lat ion supply Category I I .

The ATC-5000NG should be protected from l iquids such as spi l ls, leaks, etc. and precipitat ion such as rain, snow, etc. When moving the equipment from a cold to hot environment, al low the temperature of the equipment to stabi l ize before the Unit is connected to an AC power supply to avoid condensation forming. The equipment must only be operated within the environmental condit ions specif ied in the product specif icat ions.

This product is not approved for use in hazardous atmospheres or medical appl icat ions. I f the equipment is to be used in a safety-related applicat ion, such as avionics or mil i tary appl icat ions, the suitabi l i ty of the product must be assessed and approved for use by a competent person. Refer al l servicing of Unit to Quali f ied Technical Personnel.

PROTECTION PROVIDED BY EQUIPMENT

MAY BE IMPAIRED IF THE TEST SET IS

USED IN A MANNER NOT SPECIFIED BY

THE MANUFACTURER.

AVERTISSEMENT LA PROTECTION FOURNIE AVEC

L'EQUIPEMENT PEUT S'AVERER

INEFFICACE EN CAS

D'UTILISATION D'UNE MANIERE

NON SPECIFIEE PAR LE

FABRICANT.

Safety Identification in Technical Manual This manual uses the fol lowing terms to draw attent ion to possible safety hazards that may exist when operat ing or servicing this equipment:

IDENTIFIES CONDITIONS OR ACTIVITIES THAT, IF IGNORED, CAN RESULT IN EQUIPMENT OR PROPERTY DAMAGE, E.G. FIRE.

IDENTIFIES CONDITIONS OR ACTIVITIES

THAT, IF IGNORED, CAN RESULT IN

PERSONAL INJURY OR DEATH.

Page 6: SECTION 2 - OPERATION

ATC -5000NG Get t ing S ta r ted M anua l

Subject to Export Control, see Cover Page for detai ls.

3

Safety Symbols in Manuals and on Units

CAUTION : Refer to accompanying documents. (Symbol refers to specif ic CAUTIONS represented on the Unit and clari f ied in the text.)

Indicates a Toxic hazard.

Indicates i tem is stat ic sensit ive.

AC TERMINAL: Terminal that may supply or be supplied with AC or alternat ing voltage.

Indicates a fuse (AC or DC).

HOT SURFACE: This surface may be hot to the touch.

Case, Cover or Panel Removal

Opening the Case Assembly exposes the operator to electrical hazards that may result in electrical shock or equipment damage. Do not operate this Test Set with the Case Assembly open.

AVERTISSEMENT | ATTENTION

L'ouverture de l 'enceinte expose l 'opérateur à des dangers électriques pouvant être à l 'origine d'un choc ou de l 'endommagement de l 'équipement. Ne faites pas fonct ionner ce Test Set avec son enceinte ouverte.

Equipment Grounding Protection

Improper grounding of equipment can result in electrical shock.

AVERTISSEMENT | ATTENTION

Une masse défectueuse de l 'équipement peut être à l 'origine d'un choc électrique.

Page 7: SECTION 2 - OPERATION

ATC -5000NG Get t ing S ta r ted M anua l

Subject to Export Control, see Cover Page for detai ls.

4

Case, Cover or Panel Removal

Opening the Case Assembly exposes the operator to electrical hazards that may result in electrical shock or equipment damage. Do not operate this Test Set with the Case Assembly open.

AVERTISSEMENT | ATTENTION

L'ouverture de l 'enceinte expose l 'opérateur à des dangers électriques pouvant être à l 'origine d'un choc ou de l 'endommagement de l 'équipement. Ne faites pas fonct ionner ce Test Set avec son enceinte ouverte.

Equipment Grounding Protection

Improper grounding of equipment can result in electrical shock.

AVERTISSEMENT | ATTENTION

Une masse défectueuse de l 'équipement peut être à l 'origine d'un choc électrique.

Use of Probes

To prevent electrical shock or damage to equipment: Verify that al l the connect ions between the equipmen t and a device under test do not exceed maximum port rat ings for voltage, current and power.

AVERTISSEMENT | ATTENTION

Pour éviter tout choc électrique ou D’endommageR l 'équipement:Vérif iez que toutes les interconnexions entre l 'équipement et un périphér ique testé ne dépassent pas les valeurs maximales pour la tension, le courant et la puissance DE CHAQUE PORT.

DMM Measurement Category

The Digital Mult imeter (DMM) is classif ied in Measurement Category I I . Measurement Category I I is designated for equipment which performs measurements on circuits direct ly connected to low voltage instal lat ion.

Page 8: SECTION 2 - OPERATION

ATC -5000NG Get t ing S ta r ted M anua l

Subject to Export Control, see Cover Page for detai ls.

5

Power Cords The AC Power Cord included with the Test Set , or an appropriate replacement, should be used to connect the Test Set to a grounded AC power supply. Fai l ure to ground the Test Set may expose the operator to hazardous voltage levels.

To connect the Test Set to a Class I I (ungrounded) 2-terminal socket out let, f i t the power cord with either a 3-pin Class I plug used in conjunct ion with an adapter incorporat ing a ground wire or f i t the power cord with a Class I I plug containing an integral ground wire. The ground wire must be securely fastened to ground; grounding one terminal on a 2-terminal socket does not provide adequate protect ion.

Power cords must be in good operat ing condit ion. Power cords must not be frayed or broken, nor expose bare wiring. Using a damaged power cord may expose the operator to hazardous voltage levels.

International Power Requirements

The AC power cord must meet local regulat ions and power requirements. Check with local standards and regulat ions to ensure the power cord being used meets al l local safety regulat ions.

Page 9: SECTION 2 - OPERATION

ATC -5000NG Get t ing S ta r ted M anua l

Subject to Export Control, see Cover Page for detai ls.

6

EMI (Electromagnetic Interference)

SIGNAL GENERATORS CAN BE A SOURCE OF ELECTROMAGNETIC INTERFERENCE (EMI) TO COMMUNICATION RECEIVERS. SOME TRANSMITTED SIGNALS CAN CAUSE DISRUPTION AND INTERFERENCE TO COMMUNICATION SERVICE OUT TO A DISTANCE OF SEVERAL MILES. USER OF THIS EQUIPMENT SHOULD SCRUTINIZE ANY OPERATION THAT RESULTS IN RADIATION OF A SIGNAL (DIRECTLY OR INDIRECTLY) AND SHOULD TAKE NECESSARY PRECAUTIONS TO AVOID POTENTIAL COMMUNICATION INTERFERENCE PROBLEMS.

ATTENTION LES GENERATEURS DE SIGNAUX PEUVENT CONSTITUER UNE SOURCE D'INTERFERENCES ELECTROMAGNETIQUES ( IME) POUR LES RECEPTEURS RADIO. CERTAINS SIGNAUX EMIS PEUVENT PROVOQUER DES INTERFERENCES ET DES INTERRUPTIONS DES COMMUNICATIONS SUR UNE DISTANCE DE PLUSIEURS KILOMETRES. L'UTILISATEUR DE CET EQUIPEMENT DOIT EXAMINER SOIGNEUSEMENT TOUT FONCTIONNEMENT PROVOQUANT LE RAYONNEMENT D'UN SIGNAL (DIRECT OU INDIRECT) ET IL DOIT PRENDRE LES DISPOSITIONS NECESSAIRES AFIN D'EVITER DES PROBLEMES POTENTIELS D'INTERFERENCES SUR LES COMMUNICATIONS.

Page 10: SECTION 2 - OPERATION

ATC -5000NG Get t ing S ta r ted M anua l

Subject to Export Control, see Cover Page for detai ls.

7

Input Overload

REFER TO PRODUCT SPECIFICATIONS FOR MAXIMUM INPUT RATINGS FOR INPUT CONNECTORS.

ATTENTION REPORTEZ-VOUS AUX SPECIFICATIONS DU PRODUIT POUR LES CLASSIFICATIONS D'ENTREE MAXIMUM SUR LES CONNECTEURS D'ENTREE.

Toxic Hazards

SOME OF THE COMPONENTS USED IN

THIS EQUIPMENT MAY INCLUDE RESINS

AND OTHER MATERIALS WHICH GIVE OFF

TOXIC FUMES IF INCINERATED. TAKE

APPROPRIATE PRECAUTIONS IN THE

DISPOSAL OF THESE ITEMS.

AVERTISSEMENT CERTAINS DES COMPOSANTS

UTILISES DANS CET

EQUIPEMENT PEUVENT

CONTENIR DES RESINES ET

D'AUTRES MATERIAUX QUI

PRODUIRONT DES EMANATIONS

TOXIQUES EN CAS

D'INCINERATION. PRENEZ

TOUTES LES DISPOSITIONS

NECESSAIRES LORS DE LA MISE

AU REBUT DE CES

EQUIPEMENTS.

Page 11: SECTION 2 - OPERATION

ATC -5000NG Get t ing S ta r ted M anua l

Subject to Export Control, see Cover Page for detai ls.

8

Toxic Hazards (cont)

BERYLLIA

BERYLLIA (BERYLLIUM OXIDE) IS USED IN

THE CONSTRUCTION OF SOME OF THE

COMPONENTS IN THIS EQUIPMENT.

THIS MATERIAL, WHEN IN THE FORM OF

FINE DUST OR VAPOR AND INHALED INTO

THE LUNGS, CAN CAUSE A RESPIRATORY

DISEASE. IN ITS SOLID FORM, AS USED

HERE, IT CAN BE HANDLED SAFELY,

HOWEVER, AVOID HANDLING CONDITIONS

WHICH PROMOTE DUST FORMATION BY

SURFACE ABRASION.

USE CARE WHEN REMOVING AND

DISPOSING OF THESE COMPONENTS. DO

NOT PUT THE COMPONENTS IN THE

GENERAL INDUSTRIAL OR DOMESTIC

WASTE OR DISPATCH BY POST. THE

COMPONENTS SHOULD BE SEPARATELY

AND SECURELY PACKED AND CLEARLY

IDENTIFIED TO SHOW THE NATURE OF

THE HAZARD AND THEN DISPOSED OF IN

A SAFE MANNER BY AN AUTHORIZED

TOXIC WASTE CONTRACTOR.

OXYDE DE BERYLLIUM

AVERTISSEMENT DU BERYLLIUM (OXYDE DE

BERYLLIUM) EST UTILISE DANS

LA FABRICATION DE CERTAINS

DES COMPOSANTS DE CET

EQUIPEMENT.

CE MATERIAU PEUT

PROVOQUER UNE AFFECTION

DES VOIES RESPIRATOIRES

LORSQU'IL SE PRESENTE SOUS

LA FORME D'UNE POUSSIERE

FINE OU DE VAPEUR ET QU'IL

ATTEINT LES POUMONS. SOUS

SA FORME SOLIDE, TEL QU'IL

EST UTILISE ICI, IL PEUT ETRE

MANIPULE SANS DANGER, MAIS

IL EST PREFERABLE D'EVITER

TOUTE FORME DE

MANIPULATION POUVANT

AMENER LA FORMATION DE

POUSSIERES PAR ABRASION

DES SURFACES.

Page 12: SECTION 2 - OPERATION

ATC -5000NG Get t ing S ta r ted M anua l

Subject to Export Control, see Cover Page for detai ls.

9

Toxic Hazards (cont)

OXYDE DE BERYLLIUM

AVERTISSEMENT SOYEZ PRUDENT LORS DE LA

DEPOSE ET DE LA MISE AU

REBUT DE CES COMPOSANTS.

NE LES TRAITEZ PAS EN TANT

QUE DECHETS INDUSTRIELS OU

MENAGERS HABITUELS; NE LES

INTRODUISEZ PAS DANS LE

CIRCUIT POSTAL. ILS DOIVENT

ETRE EMBALLES SEPAREMENT

ET SOLIDEMENT, ET

CLAIREMENT IDENTIFIES AFIN

DE PRESENTER LA NATURE DU

DANGER ET D'ETRE ENSUITE

MIS AU REBUT SANS DANGER

PAR UNE ENTREPRISE

AUTORISEE DE TRAITEMENT

DES DECHETS TOXIQUES.

Page 13: SECTION 2 - OPERATION

ATC -5000NG Get t ing S ta r ted M anua l

Subject to Export Control, see Cover Page for detai ls.

10

Toxic Hazards (cont)

BERYLLIUM COPPER

SOME MECHANICAL COMPONENTS WITHIN

THIS INSTRUMENT ARE MANUFACTURED

FROM BERYLLIUM COPPER. THIS IS AN

ALLOY WITH A BERYLLIUM CONTENT OF

APPROXIMATELY 5% THAT REPRESENTS

NO RISK IN NORMAL USE.

THIS MATERIAL SHOULD NOT BE

MACHINED, WELDED OR SUBJECTED TO

ANY PROCESS WHERE HEAT IS

INVOLVED.

THIS MATERIAL MUST BE DISPOSED OF

AS “SPECIAL WASTE.”

THIS MATERIAL MUST NOT BE DISPOSED

OF BY INCINERATION.

CUPROBERYLLIUM

AVERTISSEMENT CERTAINS COMPOSANTS

MECANIQUES A L'INTERIEUR DE

CET INSTRUMENT SONT

FABRIQUES AVEC DU

CUPROBERYLLIUM. IL S 'AGIT

D'UN ALLIAGE CONTENANT

ENVIRON 5 % DE BERYLLIUM. IL

NE PRESENTE AUCUN RISQUE

DANS LE CADRE D'UNE

UTILISATION NORMALE.

CE MATERIAU NE DOIT PAS

ETRE USINE, SOUDE OU SOUMIS

A AUCUN PROCESSUS

IMPLIQUANT DE LA CHALEUR.

IL DOIT ETRE MIS AU REBUT EN

TANT QUE « DECHET SPECIAL ».

IL NE DOIT PAS ÊTRE MIS AU

REBUT PAR INCINERATION.

Page 14: SECTION 2 - OPERATION

ATC -5000NG Get t ing S ta r ted M anua l

Subject to Export Control, see Cover Page for detai ls.

11

Static Sensitive Components

CAUTION

THIS EQUIPMENT CONTAINS PARTS

SENSITIVE TO DAMAGE

BY ELECTROSTATIC DISCHARGE (ESD)

This equipment contains components sensi t ive to damage by Electrostat ic Discharge (ESD). Al l personnel performing maintenance or cal ibrat ion procedures should have knowledge of accepted ESD pract ices and/or be ESD cert i f ied.

Table of Contents

Service Upon Receipt of Material . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12

Unpacking.. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12

Checking Unpacked Equipment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13

Specif icat ions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15

Instal lat ion . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16

Safety Precautions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16

Complying with Instruct ions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16

AC Power Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16

Venti lat ion . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16

Grounding Power Cord . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16

Operat ing Safety . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17

Instal lat ion Procedure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17

Bench Use . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17

Rack Mount . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17

External Cleaning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18

Controls, Connectors and Indicators . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19

Front Panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19

Rear Panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20

Power On/Off Procedures . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22

Power ON Test Set . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22

Power OFF Test Set . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22

Touch Screen . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23

Screen Features and Icons . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23

Menus and Screens . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26

Page 15: SECTION 2 - OPERATION

ATC -5000NG Get t ing S ta r ted M anua l

Subject to Export Control, see Cover Page for detai ls.

12

1.0 SERVICE UPON RECEIPT OF MATERIAL

1.1 Unpacking

Special-design packing material inside the shipping container provides maximum protect ion for the ATC-5000NG. Avoid damaging the shipping container and packing material during equipment unpacking.

Use the fol lowing steps to unpack the Test Set:

STEP PROCEDURE

1. Cut and remove the seal ing tape on top of the shipping container and open the shipping container.

2. Remove the top packing mold.

3. Remove ATC-5000NG and packing material f rom the bottom packing mold.

4. Remove the protect ive p last ic bag from the ATC-5000NG and inspect the contents.

5. Place the protect ive plast ic bag and packing material inside the shipping container.

6. Store the shipping container for future use should the ATC-5000NG need to be returned/shipped.

Page 16: SECTION 2 - OPERATION

ATC -5000NG Get t ing S ta r ted M anua l

Subject to Export Control, see Cover Page for detai ls.

13

1.2 Checking Unpacked Equipment

Check the equipment for damage incurred during shipment. I f the equipment has been damaged or i f i tems seem to be absent from the shipment, report the damage and/or discrepancies to Aerof lex Customer Service.

Contact:

Aeroflex

Attn: Customer Service

10200 West York Street

W ichita, Kansas 67215

Telephone: (800) 835-2350 (U.S. only)

(316) 522-4981

FAX: (316) 529-5330

email : [email protected]

Standard Items

DESCRIPTION PART

NUMBER

QTY

ATC-5000NG 138156 1

Manual, Gett ing Started (Paper) 139189 1

Manual, Operat ion (CD) 139188 1

Power Cable (AC) (110 Use) (US Only)

62302 1

Power Cables (AC) (220 Use) (Europe)

64020 1

Touchpad 114114 1

Refer to the ATC-5000NG Operat ion Manual for Optional I tems avai lable for the ATC-5000NG ATC/DME Test Set .

Page 17: SECTION 2 - OPERATION

ATC -5000NG Get t ing S ta r ted M anua l

Subject to Expor t Control, see Cover Page for detai ls.

14

ATC-5000NG Manual, Getting Started

(Paper)

Manual, Operation

(CD)

Power Cable (AC)

(110 Use) (US Only)

138156 139189 139188 62302

Operation / ICW Manual

(61105 (1002-6200-2C0)

Power Cable ( AC ) ( North America )

( 27478 )

Power Cables (AC)

(220 Use) (Europe)

Touchpad

64020 114114

Page 18: SECTION 2 - OPERATION

ATC -5000NG Get t ing S ta r ted M anua l

Subject to Export Control, see Cover Page for detai ls.

15

2.0 SPECIFICATIONS

ENVIRONMENTAL / PHYSICAL

Overall Dimensions 10.5 in (H) X 19 in (W) X 24 in (D) (26.7 cm, 48.3 cm, 60.9 cm)

Weight 41 lbs. (19 kg)

AC INPUT POWER

Voltage Range 100 to 240 VAC, 50 to 60 Hz

Usage Environment Indoor Use

Operating Temperature

0C to +40C

23C (5C) Ful l Specif ied Performance

Storage Temperature

0C to +71C

Relative Humidity 0% to 95% non-condensing

Degree of Protection IPX-0

(Specifications are subject to change without notice.)

Page 19: SECTION 2 - OPERATION

ATC -5000NG Get t ing S ta r ted M anua l

Subject to Export Control, see Cover Page for detai ls.

16

3.0 INSTALLATION

3.1 Safety Precautions

The fol lowing safety precautions must be observed during instal lat ion and operat ion. Aerof lex assumes no l iabi l i ty for fai lure to comply with any safety precaution out l ined in this manual.

3.1.A Complying with Instructions

Instal lat ion/operat ing personnel should not attempt to instal l or operate the Test Set without reading and complying with instruct ions contained in this manual. Al l procedures contained in this manual must be performed in exact sequence and manner described.

3.1.B AC Power Requirements

The ATC-5000NG power supply operates over a voltage range of 100 to 120 VAC at 60 Hz or 220 to 240 VAC at 50 Hz.

3.1.C Ventilation

The RGS-2000NG is air-cooled by fans that draw air through vents in the case. Do not onstruct the air vents while the instrument is in use. Avoid standing the instrument on or close to other equipment that is hot .

3.1.D Grounding Power Cord

Use a 3-prong AC Power Cord to connect the Test Set to a grounded AC Power Supply.

DO NOT USE A THREE-PRONG TO TWO-

PRONG ADAPTER PLUG. DOING SO

CREATES A SHOCK HAZARD BETWEEN

THE CHASSIS AND ELECTRICAL GROUND.

AVERTISSEMENT N’UTILISEZ PAS D’ADAPTATEUR

À TROIS BROCHES SUR UNE

PRISE À DEUX BROCHES.

L'INOBSERVATION DE CETTE

CONSIGNE PEUT CRÉER UN

DANGER DE CHOC ENTRE LE

CHÂSSIS ET LA MASSE

ÉLECTRIQUE.

For AC operat ion, the AC Line Cable, connected to the External DC Power Supply, is equipped with a standard three-prong plug and must be connected to a properly grounded three-prong receptacle.

I t is the customer's responsibi l i ty to:

Have a qual i f ied electric ian check receptacle(s) for proper grounding.

Replace any standard two-prong receptacle(s) with properly grounded three-prong receptacle(s).

Page 20: SECTION 2 - OPERATION

ATC -5000NG Get t ing S ta r ted M anua l

Subject to Export Control, see Cover Page for detai ls.

17

3.1.E Operating Safety

DUE TO POTENTIAL FOR ELECTRICAL

SHOCK WITHIN THE TEST SET, THE CASE

ASSEMBLY MUST BE CLOSED WHEN THE

TEST SET IS CONNECTED TO AN

EXTERNAL POWER SOURCE.

AVERTISSEMENT L'ENCEINTE DU TEST SET DOIT

ETRE FERMEE EN RAISON DE

CHOCS ELECTRIQUES

POSSIBLES LORSQUE

L'APPAREIL EST CONNECTE A

UNE SOURCE D'ALIMENTATION

EXTERNE.

Extreme care should be exercised when performing any operat ions preceded by a CAUTION or WARNING label. CAUTION labels appear where possibi l i ty of damage to equipment exists and WARNING labels denote condit ions where bodily injury or death may result .

3.2 Installation Procedure

3.2.A Bench Use

STEP PROCEDURE

1. Set the ATC-5000NG into operat ing posit ion.

2. Connect the AC Power Cable from the AC INPUT Connector to an external AC power source (100 to 240 VAC at 60 to 50 Hz).

The AC Power Cable is used to ful ly disconnect the Test Set from AC Power. The Test Set should not be posit ioned so the disconnect ion of the AC Power Cable is prevented.

3. Set the Power Switch (on the Test Set Rear Panel) to the ON posit ion (I).

4. Press the Power Switch (on the Test Set Front Panel). The Power Switch Indicator l ights and the Test Set starts the power-up sequence.

3.2.B Rack Mount

Contact Aerof lex for information on instal l ing the ATC-5000NG in a rack.

Page 21: SECTION 2 - OPERATION

ATC -5000NG Get t ing S ta r ted M anua l

Subject to Export Control, see Cover Page for detai ls.

18

4.0 EXTERNAL CLEANING

This sect ion contains rout ine instruct ions for c leaning the outside of the Test Set.

DISCONNECT POWER FROM TEST SET TO AVOID POSSIBLE DAMAGE TO ELECTRONIC CIRCUITS.

ATTENTION DEBRANCHEZ L'ALIMENTATION DU TEST SET AFIN D'EVITER D'ENDOMMAGER LES CIRCUITS ELECTRIQUES.

Clean front panel buttons with soft l int -free cloth. I f

dirt is dif f icult to remove, dampen cloth with water and a mild l iquid detergent.

Clean Front Panel display with soft l int -free cloth dampened (not soaked) with non-ammonia based glass cleaner.

Remove grease, fungus and ground-in dirt f rom surfaces with soft l int -free cloth dampened (not soaked) with isopropyl alcohol.

Remove dust and dirt f rom connectors with soft -brist led brush.

Cover connectors, not in use, wi th suitable dust cover to prevent tarnishing of connector contacts.

Clean cables with soft l int -free cloth.

Paint exposed metal surface to avoid corrosion.

Page 22: SECTION 2 - OPERATION

ATC -5000NG Get t ing S ta r ted M anua l

Subject to Export Control, see Cover Page for detai ls.

19

5.0 CONTROLS, CONNECTORS AND

INDICATORS

5.1 Front Panel Controls, Connectors and

Indicators

Refer to Numerical Reference Charts for connector cross -reference. Controls, Connectors and Indicators are l isted by numerical reference.

# Name Description

1 Color LCD

Touch Screen

Used to interact with the Test Set menus.

2 Power Switch /

Indicator

Used for turning the Test Set ON and OFF. Indicator is l i t when the Test Set is ON.

3 USB Connectors Type A Connectors used for interface to external USB devices (keypad, mouse, f lash drive, etc.) .

Type B Connector used for remote control of the Test Set.

4 LAN Connector Used for remote control of the Test Set via TCP/IP.

5 SUPP Connector Used for test ing of the UUT (suppressor output) .

6 SCOPE

Connectors

Used for test ing of the UUT.

7 RF I/O

Connectors

(TOP, BOTTOM)

Used for test ing of the UUT.

Page 23: SECTION 2 - OPERATION

ATC -5000NG Get t ing S ta r ted M anua l

Subject to Export Control, see Cover Page for detai ls.

20

5.2 Rear Panel Connectors

Refer to Numerical Reference Charts for connector cross -reference. Connectors are l isted by numerical reference.

# Name Description

1 LAN Connector Used for remote control of the Test Set via TCP/IP.

2 AUX CONTROL

Connector

Future Use

3 SA TOP

Connector

Used for coupled output from the Top Receiver (Spectrum Analyzer).

4 SA BOTTOM

Connector

Used for coupled output from the Bottom Receiver (Spectrum Analyzer).

5 EXTERNAL

PULSE

MODULATION

Connectors

Used for I /O applicat ions with external equipment.

6 SCOPE

Connectors

Used for test ing of the UUT.

7 SUPP Connector Used for test ing of the UUT (suppressor output).

8 ATE Line

Connector

Used for connect ion to external equipment. The connector contains discrete inputs, discrete outputs and 429 Tx/Rx.

Page 24: SECTION 2 - OPERATION

ATC -5000NG Get t ing S ta r ted M anua l

Subject to Export Control, see Cover Page for detai ls.

21

5.2 Rear Panel Connectors (cont)

# Name Description

9 GPIB Bus

Connector

24-pin female connector conforming to IEEE standard 488-1978 for interface of general purpose programmable instrumentat ion.

10 Power

Connector

Standard 3-prong power receptacle for connect ion to AC power source (100 to 240 VAC, 50 to 60 Hz).

11 Power Switch Connects (I) or disconnects (O) external AC power from the ATC-5000NG.

Page 25: SECTION 2 - OPERATION

ATC -5000NG Get t ing S ta r ted M anua l

Subject to Export Control, see Cover Page for detai ls.

22

6.0 POWER ON/OFF PROCEDURES

6.1 Power ON Test Set

STEP PROCEDURE

1. Press the Power Switch (Front Panel) to power ON the Test Set.

2. Verify the Power Switch Indicator i l luminates.

3. Wait while the Test Set completes the power-up sequence.

The ATC-5000NG Main Menu is displayed.

6.2 Power OFF Test Set

STEP PROCEDURE

1. Press the Power Switch (Front Panel) to power OFF the Test Set.

2. Verify the Power Switch Indicator is not i l luminated.

(Th is scr een is a r epr esenta t ion o f the scr een tha t appear s . )

(Opt iona l Funct ions a r e shown for d isp lay pur poses on ly . )

Page 26: SECTION 2 - OPERATION

ATC -5000NG Get t ing S ta r ted M anua l

Subject to Export Control, see Cover Page for detai ls.

23

7.0 TOUCH SCREEN

The ATC-5000NG contains a resist ive Touch Screen that is responsive to the touch of a human f inger. Gloves can be worn when ut i l izing the Touch Screen or a writ ing instrument (e.g. stylus) can be used on the Touch Screen.

8.0 SCREEN FEATURES AND ICONS

Screen Icons

Screen Features

Page 27: SECTION 2 - OPERATION

ATC -5000NG Get t ing S ta r ted M anua l

Subject to Export Control, see Cover Page for detai ls.

24

8.0 SCREEN FEATURES AND ICONS (cont)

Icon Description

External equipment is connected to the LAN Connector (Front or Rear Panel) .

External equipment is not connected to the LAN Connector (Front or Rear Panel).

External equipment is connected to the USB Connector.

External equipment is not connected to the USB Connector.

External equipment is connected to the GPIB Connector.

External equipment is not connected to the GPIB Connector.

The conf igurat ion does not match with the subassemblies present in the system or a DSP or FPGA f irmware version is incorrect.

Icon Description

An error has occurred. Place the mouse cursor over the icon to see a descript ion of the error or double cl ick on the icon to go to the Error Menu to see a l ist of errors.

Press this icon to open safely remove hardware dialog.

Opens the on-screen keyboard for data entry.

Press this icon to open Windows Explorer.

Page 28: SECTION 2 - OPERATION

ATC -5000NG Get t ing S ta r ted M anua l

Subject to Export Control, see Cover Page for detai ls.

25

8.0 SCREEN FEATURES AND ICONS (cont)

Feature Description

Local Mode - Al l controls on the Touchscreen are enabled.

Remote Mode - Al l controls on the touchscreen are disabled.

Softkeys are used to display a menu, funct ion screen or access a menu f ield.

A green arrow to the right on the Softkeydisplays addit ional Softkeys.

When green, press the arrow to display addit ional Softkeys.

Inact ive when gray.

When green, press the arrow to display addit ional Softkeys.

Inact ive when gray.

Touchscreen Mode - Press a control to display a numeric keypad, keyboard or l istbox for select ion or entry of the parameter.

Feature Description

Normal Mode - Controls are modif ied using an external mouse or keypad.

When green, the previous menu is displayed.

Inact ive when gray.

Page 29: SECTION 2 - OPERATION

ATC -5000NG Get t ing S ta r ted M anua l

Subject to Export Control, see Cover Page for detai ls.

26

9.0 MENUS AND SCREENS

Main Menu

(Th is scr een is a r epr esenta t ion o f the scr een tha t appear s . )

(Opt iona l Funct ions a r e shown for d isp lay pur poses on ly . )

Multi-Receiver Menu

(Th is scr een is a r epr esenta t ion o f the scr een tha t appear s . )

Page 30: SECTION 2 - OPERATION

ATC -5000NG Get t ing S ta r ted M anua l

Subject to Export Control, see Cover Page for detai ls.

27

9.0 MENUS AND SCREENS (cont)

Transponder Menu

(Th is scr een is a r epr esenta t ion o f the scr een tha t appear s . )

DME Menu

(Th is scr een is a r epr esenta t ion o f the scr een tha t appear s . )

(The DME Menu is an Opt iona l F unct ion in the ATC -5000NG . )

Page 31: SECTION 2 - OPERATION

ATC -5000NG Get t ing S ta r ted M anua l

Subject to Export Control, see Cover Page for detai ls.

28

9.0 MENUS AND SCREENS (cont)

UAT Menu

(Th is scr een is a r epr esenta t ion o f the scr een tha t appear s . )

(The UAT Menu is an Opt iona l Funct ion in the ATC -5000NG . )

System Menu

(Th is scr een is a r epr esenta t ion o f t he scr een tha t appear s . )

Page 32: SECTION 2 - OPERATION

ATC -5000NG Get t ing S ta r ted M anua l

Subject to Export Control, see Cover Page for detai ls.

29

9.0 MENUS AND SCREENS (cont)

Support Menu

(Th is scr een is a r epr esenta t ion o f the scr een tha t appear s . )

Page 33: SECTION 2 - OPERATION

ATC -5000NG Get t ing S ta r ted M anua l

Subject to Export Control, see Cover Page for detai ls.

30

THIS PAGE INTENTIONALLY LEFT BLANK.

Page 34: SECTION 2 - OPERATION

Our passion for performance is defined by threeattributes represented by these three icons:

solution-minded, performance-driven, customer-focused.

As we are always seeking to improve our products, the information in

this document gives only a general indication of the product capacity,

performance and suitability, none of which shall form part of any

contract. We reserve the right to make design changes without notice.

EXPORT CONTROL WARNING: This document contains controlled technicaldata under the jurisdiction of the Export Administration Regulations (EAR), 15 CFR 730-774. It cannot be transferred to any foreign third party withoutthe specific prior approval of the U.S. Department of Commerce, Bureau ofIndustry and Security (BIS). Violations of these regulations are punishable by fine, imprisonment, or both.

*139189*139189 D0

DIR: 10000040378 DA

Go to http://ats.aeroflex.com/contact/sales-distribution for Sales and Service contact information.