Upload
jessica-blake
View
27
Download
2
Embed Size (px)
Citation preview
Europa House, Alfold Road, Cranleigh, GU6 8NQ 01483 269999 [email protected] www.sertussystems.co.uk
Compliance without compromise
THE SMOKE ANDACCESS SPECIALISTS
about sertus
For more than 25 years we’ve been
supplying high-performance, fully
certificated and approved smoke
vents and roof access hatches, and
compatible accessories ranging from
control panels to access ladders.
As well as our unrivalled range of
stock products, we advise, design,
manufacture and install bespoke smoke
ventilation and access systems on
virtually any scale, anywhere in the UK.
The Sertus service is shaped by each
client’s particular needs; you can choose
straightforward supply-only or a full-
service design and support package. Our
offering incorporates certification advice,
design consultation and roof surveys,
through to bespoke CAD drawing and
custom design, as well as a reassuring
level of post-installation support.
This brochure gives you a brief overview
of our most popular products. You’ll
find the full Sertus range, performance
details, CAD and BIM drawings and
NBS+ specifications on our website
www.sertussystems.co.uk
Our expert team are always happy
to help answer any questions, give
technical advice and, of course, ensure
your next project receives the attention
to detail it deserves. Please feel free to
get in touch at any time.
SerTUS IS The SPeCIAlIST SMOKe AND ACCeSS DIvISION
OF WhITeSAleS, ONe OF The UK’S MOST exPerIeNCeD AND
reSPeCTeD SUPPlIerS OF rOOFlIghTS.
For expert technical advice and to place your order,
please contact the Sertus technical team.
a europa house, Alfold road, Cranleigh, gU6 8NQ
t 01483 269999
W www.sertussystems.co.uk
Why performance in smoke control matters
statistics from the Department for
communities and local Government
reveal that 53% of all fire-related fatalities
are attributed to people being overcome
by smoke or gas, rather than dying from
the fire itself. smoke vents are life-saving
devices that greatly increase occupants’
chances of survival in the event of
fire outbreak.
as well as keeping escape and access
routes smoke-free, sheVs delay or
prevent flashover to slow or stop fire
developing to devastating levels. they
help firefighters tackle blazes more
safely, effectively and quickly, resulting in
reduced structural and material damage
to buildings.
essential certificationAs life-saving devices, any smoke vent
supplied must be built to meet or exceed
the eN12101-2 standard. This involves
passing rigorous testing against strict
criteria for:
• Determinationofaerodynamic
free area
• Reliability
• Openingunderload
• Lowambienttemperature
• Windload
• Heatexposure
All ShevS manufacturers’ products must
pass several tests carried out by a fully
independent test laboratory. Always look
out for the compulsory Ce mark, be sure
to obtain your declaration of performance
from the manufacturer and carefully
examine your products before installation.
All Sertus smoke and access products are
designed and manufactured to ISO 9001,
Ce marked and fully certified, and meet
the requirements of Building regulations
ADB and ADl.
The principle behind smoke and heat
exhaust ventilation systems (ShevS) is
to reduce the potentially fatal build-up
of smoke and heat, leaving an area of
clear air above the floor.
For further information on the
legal requirements of smoke vents
and access systems, please visit
www.sertussystems.co.uk, contact
our technical team on 01483 269999
or email [email protected].
02
case stuDy
PrOjeCT: Baylis Old School
SCOPe: Smoke control and natural smoke
ventilation in an award-winning
residential scheme
PrODUCTS: em-vent & control panels
em-Vent smoke Vents
em-vent is a high-performance flat-roof smoke vent, fully
certified to BS eN12101-2 and designed for commercial,
leisure, retail and residential developments and
refurbishments. em-vent electrically operated smoke
vents open to 160° in under 60 seconds, releasing smoke
and heat fast to keep stairwells, corridors and escape
routes clear.
em-vents can also provide natural ventilation and can be
operated for roof access and maintenance.
You can choose a solid insulated aluminium cover, or glass
or polycarbonate glazed rooflight to fill internal areas with
daylight.
benefits
• 74+sizesavailable,manystraightfromstock,insquare,
rectangular and circular shapes
• Opensto160°within60secondsforimmediate,effective
smoke and heat clearance
• Choiceofcleardoubleglazedglassorsingle,double,
triple or quad-skin polycarbonate glazing, with clear, opal
diffused, bronze or heatreflect finish
• Polycarbonateandglassarenon-fragileandimpact-
resistanttoEN18731200joules
• Optionalwinddeflectorincreasesaerodynamicvalue
• Choiceofupstandtypesandheightsavailable
• Em-VentSmokeControlPanelandaccessoriesprovide
fully compliant control
• Fallarrestgridtopreventfallsfromheightwhenopen
Exceedingminimumstandards
• CEmarkedandfullycertifiedtoBSEN12101-2
• ManufacturedtoISO9001
• AssistscompliancewithBuildingRegulationsADB
and aDl
europa house, Alfold road, Cranleigh, gU6 8NQ t 01483 269999 e [email protected] W www.sertussystems.co.uk
04
es-Vent inDustrial smoke Vents
es-vent smoke vents are single and double-leaf smoke
ventilators designed for use in industrial buildings.
They’re certified to exceed all the requirements of BS
eN12101-2. The integral 24v actuator automatically opens
the single-leaf vent to 140° and the double-leaf to 90°
in less than a minute, to clear stairwells, corridors and
factory areas of smoke and heat build-up fast.
They can also provide natural comfort ventilation and
roof access.
All es-vents can be specified with solid insulated covers
or impact-resistant multiwall polycarbonate covers to
double as skylights.
benefits
• 80standardsizesavailableupto3mx3m,delivered
preassembled
• Fullyopenswithin60secondsforeffectivesmokeand
heat clearance
• Variousmultiwallpolycarbonateglazingoptions,with
clear or opal diffused finish
• Polycarbonateglazingis250timesstrongerthanglass,
non-fragileandimpact-resistanttoEN18731200joules
• Optionalwinddeflectorsincreaseaerodynamicvalue
• Choiceofinsulatedupstandsavailableinvariousheights
• Em-VentSmokeControlPanelsandaccessoriesprovide
fully compliant control
• Fallarrestgridtopreventfallsfromheightwhenopen
Exceedingminimumstandards
• CEmarkedandfullycertifiedtoBSEN12101-2
• AssistscompliancewithBuildingRegulationsADB
and aDl
es-louVre air supply Vents
es-louvre is a specialist smoke vent for rapid smoke and
heat exhaust from large buildings, particularly those
exposed to high wind loads. Its superlative performance
has been independently tested and certified to
eN12101-2. The smoke ventilators can be supplied in
various standard sizes or custom-built for specific smoke
ventilation requirements.
You can select aluminium insulated louvre blades or
polycarbonate multiwall glazing for additional daylight.
benefits
• Rapidheatandsmokeexhaust
• CanbeintegratedintoBMSorsuppliedwith
dedicated controls
• Excellentresistancetowindload
• Availableinstandardstocksizesormadetomeasure
upto2500mmx3800mm.
• Availablewithpolycarbonateglazingorsolidblades
• Highsecurityandfallarrest
• Certifiednon-fragiletoEN18731200joules
Exceedingminimumstandards
• CEmarkedandfullycertifiedtoEN12101-2
• AssistscompliancewithBuildingRegulationsADB
and aDl
06
europa house, Alfold road, Cranleigh, gU6 8NQ t 01483 269999 e [email protected] W www.sertussystems.co.uk
em-hatch roof access hatches
Access hatches allow direct, safe and easy access to flat
roofs for maintenance or as part of a fire escape route.
The em-hatch is a modular roof hatch, fully certified to
eN1873, designed for new-build or refurbishments of
residential and commercial schemes.
The em-hatch can be controlled with telescopic gas
or friction struts, electrically, and as part of a smoke
ventilation system. It can be specified with either glass or
polycarbonate glazing to maximise natural light.
benefits
• Availableinawiderangeofsizes(forlargersizessee
our es-hatch range)
• Safe,directaccesstoroofs–noexternalstairwaysor
ladders needed
• Canbeintegratedintofireescapeandsmoke
ventilation systems
• Manuallyorelectricallyopening
• Hinged,solidinsulatedpolycarbonateorglass,and
cantilevered sliding glass options
• Accessoriesincludeladders,ladderpostsandhandrails
Exceedingminimumstandards
• CEmarkedandfullycertifiedtoEN1873
• AssistscompliancewithBuildingRegulationsADB
and aDl
08
es-hatch inDustrial roof access hatches
es-hatch is our industrial roof access hatch, Ce marked
and certified to eN1873. It’s designed to give safe access
to flat roofs on manufacturing and industrial buildings,
eradicating the need for additional stairways and ladders.
We can deliver our industrial access hatches from stock
in sizes up to more than 3300mm long. We can even
supply bespoke sizes made to measure.
Internal and external locking options ensure high
security, and thermal and acoustic insulation is excellent.
Privacy is assured with a solid insulated aluminium cover
or, for additional daylighting, polycarbonate glazing.
benefits
• Awiderangeofstandardstocksizesupto3300mmlong
• Safe,directaccesstoroofs–noexternalstairwaysor
ladders needed
• Canbeintegratedintofireescaperoutes
• Internalandexternallocking
• 40mmrigidinsulatedcoverordaylight-enhancing
polycarbonate glazing
• Certifiednon-fragiletoEN18731200joules
• Accessoriesincludeladders,ladderpostsandhandrails
Exceedingminimumstandards
• CEmarkedandfullycertifiedtoEN1873
• AssistscompliancewithBuildingRegulationsADB
and aDl
europa house, Alfold road, Cranleigh, gU6 8NQ t 01483 269999 e [email protected] W www.sertussystems.co.uk
em-hatch roof access hatches
Access hatches allow direct, safe and easy access to flat
roofs for maintenance or as part of a fire escape route.
The em-hatch is a modular roof hatch, fully certified to
eN1873, designed for new-build or refurbishments of
residential, commercial and industrial schemes.
The em-hatch can be controlled with telescopic gas
or friction struts, electrically, and as part of a smoke
ventilation system. It can be specified with either glass
or polycarbonate glazing to maximise natural light.
benefits• Availableinawiderangeofsizes(forlargersizesseeourEs-hatch range)• Safe,directaccesstoroofs–noexternalstairwaysorladdersneeded• Canbeintegratedintofireescapeandsmokeventilationsystems• Manuallyorelectricalopening• Hinged,solidinsulatedpolycarbonateorglass,andcantilevered sliding glass options• Accessoriesincludeladders,ladderpostsandhandrails
Exceedingminimumstandards• CEmarkedandfullycertifiedtoEN1873• ManufacturedtoISO9001• AssistscompliancewithBuildingRegulationsADBandADL
em-Vent smoke control panels
The em-vent Smoke Control Panel allows full control
of smoke and heat ventilation when using electrically
operated opening systems. Accessories include a
fireman’s priority switch, manual control point, or smoke
and heat detectors. The control panel is certified to BS
eN12101-10 and designed to BS eN12101-9 (draft).
As well as its smoke-safety attributes, the control panel
is also effective at controlling comfort ventilation using
room thermostats, wind and rain sensors, or comfort and
key switches.
The control panel is equally efficient whether used as
a stand-alone zone system, integrated into a fire-alarm
system or building-management system, or as part of a
network of control panels. When combined with the em-
vent, es-vent, or es-louvre smoke vents, the em-vent
Smoke Control Panel offers the complete solution to
your smoke ventilation needs.
benefits
• Fireman’spriorityswitchgivingthehighest
priority control
• Smokeandheatdetectorsforearlyfiredetection
• Comfortswitchformanualcontrolofventilation
• Roomthermostatthatautomatesopeningandclosing
• Windandrainsensorsforautomaticclosureduring
bad weather
• VisibleLEDindicatorsand72-hourbatteryback-up.
Exceedingminimumstandards
• FullCEmarkings
• CertifiedtoBSEN12101-9andBSEN12101-10
control panel smoke controls comfort controls
10
The Sertus service doesn’t stop at supplying smoke vents
and roof access hatches. We also offer help and expertise to
architects, mechanical consultants, electrical consultants,
building control officers, and fire officers operating in both
the new-build and refurbishment markets.
Helpingyouandyourproject
Whether you need fire strategy support, data, detailed
drawings and specifications or wiring schematics, our
team is here to help you. We also run CPD seminars
to help you with the design and installation of smoke
control systems.
Guiding you on certification and compliance
When it comes to regulation and legislation we
know what’s what. If you need help we can guide you
through the plethora of British Standards certification
and codes of practice that surround smoke and heat
ventilation systems.
the sertus serVice
For an at-a-glance view of how our products will work on your building or project, we’ve developed a visual roofscape product selector.
try out the interactiVe
Version at
WWW.sertussystems.co.uk
europa house, Alfold road, Cranleigh, gU6 8NQ t 01483 269999 e [email protected] W www.sertussystems.co.uk
Europa House, Alfold Road, Cranleigh, GU6 8NQ 01483 269999 [email protected] www.sertussystems.co.uk
Compliance without compromise
THE SMOKE ANDACCESS SPECIALISTS