Upload
others
View
6
Download
0
Embed Size (px)
Citation preview
1500
NOTE
ALL DIMENSIONS ARE IN
MILLIMETRES. USE TREE
SPECIES TOLERANT TO
POORLY DRAINED SOIL
CONDITIONS
3
1
PLACE 1/3 OF ROOT BALL ABOVE GRADE. CUT AND
REMOVE BURLAP AND WIRE BASKET FROM TOP 1/3 OF
ROOTBALL WITHOUT DISTURBING ROOTS.
CONSTRUCT 100mm SAUCER AROUND TREE BASE. FILL WITH
75mm WOODCHIP MULCH. PULL BACK MULCH FROM BASE OF
TREE. ENSURE THAT MULCH COVERS ALL EXPOSED SOIL.
TREE WRAP APPLIED SPIRALLY FROM GROUND UP TO
HEIGHT OF SECOND BRANCHES.
REMOVE DAMAGED OR OBJECTIONABLE BRANCHES.
FOLLOW PROPER HORTICULTURAL PRACTICE. DO NOT
PRUNE LEADER
2 STAKES MIN 2400mm LONG WITH NO. 12 GALVANIZED WIRE
ENCASED IN 12mm DIAMETER RUBBER HOSE ALLOWING SLACK
IN GALVANIZED WIRE. REMOVE STAKES AFTER ONE YEAR. STAKE
BEYOND EDGE OF ROOTBALL.
ROOT COLLAR TO BE
SET 100mm ABOVE
FINISHED GRADE.
TAPER TO BLEND NATURALLY WITH FINISHED GRADE
TOPSOIL MIXTURE AS PER SPECIFICATIONS
COMPACTED
ROOTBALL
SUPPORT PAD
2300
ROOTBALL
CONSTRUCT 100mm SAUCER AROUND TREE BASE. FILL WITH
75mm WOODCHIP MULCH. PULL BACK MULCH FROM BASE OF
TREE. ENSURE THAT MULCH COVERS ALL EXPOSED SOIL.
REMOVE DAMAGED OR OBJECTIONABLE BRANCHES.
FOLLOW PROPER HORTICULTURAL PRACTICE. DO NOT
PRUNE LEADER
PLACE 1/3 OF ROOT BALL ABOVE GRADE. CUT
AND REMOVE BURLAP AND WIRE BASKET FROM
TOP 1/3 OF ROOTBALL WITHOUT DISTURBING
ROOTS.
COMPACTED ROOTBALL SUPPORT PAD
TOPSOIL MIXTURE AS PER SPECIFICATIONS.
600mm WOODEN STAKE TO EXTEND INTO UNDISTURBED SOIL
TAPER TO BLEND NATURALLY WITH FINISHED
GRADE
ROOT COLLAR TO BE SET 100mm ABOVE
FINISHED GRADE.
NOTE
ALL DIMENSIONS ARE IN MILLIMETRES. USE TREE SPECIES TOLERANT TO POORLY DRAINED SOIL CONDITIONS
2300
1500
ROOTBALL
PLANTING BED AROUND SHRUBS. COVER ENTIRE BED WITH 75mm DEPTH
WOODCHIP MULCH. PULL BACK MULCH FROM BASE OF SHRUBS. ENSURE THAT
MULCH COVERS ALL EXPOSED SOIL.
REMOVE POTS COMPLETELY FROM POTTED STOCK OR CUT AND REMOVE
BURLAP AND WIRE FROM TOP 1/3 OF ROOTBALL
REMOVE DAMAGED OR OBJECTIONABLE BRANCHES. FOLLOW PROPER
HORTICULTURAL PRACTICE.
TAPER TO BLEND NATURALLY WITH FINISHED GRADE
TOPSOIL MIXTURE AS PER SPECIFICATIONS.
15
0
EXISTING TREE
1.2m SNOW FENCE WIRED (MIN 3) TO STEEL 'T'
BAR POSTS (@ 2.4m O.C. MAX.) 50 x 150 WOOD
TOP RAIL BOLTED TO POSTS.
NOTES:
• INSTALL FENCE PRIOR TO ANY CONSTRUCTION
ACTIVITY.
• NO CONSTRUCTION ACTIVITIES INCLUDING
MATERIAL STORAGE OR DISPOSAL, OR PARKING IS
TO TAKE PLACE WITHIN THE DESIGNATED
PROTECTION AREA.
• ANY ROOTS ENCOUNTERED, ARE TO BE CLEANLY
CUT WITH A SAW OR PRUNERS (DO NOT USE
BACKHOE OR OTHER HEAVY EQUIPMENT). ROOTS
ARE TO BE COVERED IMMEDIATELY WITH TOPSOIL,
BURLAP OR MULCH AND KEPT DAMP.
PROTECTION MEASURES TO BE TAKEN DURING CONSTRUCTION:
1. UNDER THE GUIDANCE OF AN ARBORIST, ERECT A FENCE AT THE CRITICAL ROOT ZONE (CRZ) OF TREES
WHERE THE CRZ IS ESTABLISHED AS BEING 10 CENTIMETRES FROM THE TRUNK OF A TREE FOR EVERY
CENTIMETRE OF TRUNK DIAMETER AT BREAST HEIGHT. THE CRZ IS CALCULATED AS DBH X 10 CM.;
2. DO NOT PLACE ANY MATERIAL OR EQUIPMENT WITHIN THE CRZ OF THE TREE
3. DO NOT ATTACH ANY SIGNS, NOTICES OR POSTERS TO ANY TREE;
4. DO NOT RAISE OR LOWER THE EXISTING GRADE WITHIN THE CRZ WITHOUT APPROVAL;
5. TUNNEL OR BORE WHEN DIGGING WITHIN THE CRZ OF A TREE;
6. DO NOT DAMAGE THE ROOT SYSTEM, TRUNK, OR BRANCHES OR ANY TREE;
7. ENSURE THAT EXHAUST FUMES FROM ALL EQUIPMENT ARE NOT DIRECTED TOWARDS ANY TREE CANOPY.
1200m
m
³
FIRE STATION
ESSO
SERVICE STATION
(TO BE CONFIRMED)
HAZELDEAN ROAD
IB
ER
R
OA
D
FR
IN
GE
WO
OD
D
RIV
E
BLDG G
FUTURE
BLDG B
RETAIL / AM
BLDG A
RETAIL / AM
AM7 ZONE
DRUG STORE
MEDICAL
RETAIL
RETAIL
BICYCLE
BICYCLE
FRINGEWOOD PARK
PUMPING
STATION
SERVICE
BLDG C
NO FRILLS
BLDG D
RETAIL
CRU BB1
AM9 ZONE
IL ZONE
L1 ZONE
BLOCK C PARKING
BOUNDARY
DITCH
EASEMENT
CRU B1
CRU B7
CRU B2
CRU B3
CRU B4
CRU B5
CRU B6
BLDG BB
RETAIL / AM
2
HL
17
JT
52
BF
1
GB
16
SG
20
BF
10
MP
20
BF
10
MP
2
GB
21
MP
1
EL
9
MP
12
BF
35
SG
2
GB
10
MP
20
BF
2
GB
10
MP
20
BF
16
SG
1
GB
52
BF
17
MP
2
HL
20
MP
16
SJ
28
PO
18
DL
28
PO
6
SG
7
AW
19
PO
13
RR
21
SG
12
RR
20
SG
12
RR
15
GS
12
PO
60
DL
9
KF
30
DL
30
DL
19
GS
22
PO
30
DL
26
MP
80
DL
2
SB
2
JL
1
SB
3
SB
3
HL
2
EL
3
BC
3
RM
2
RM
3
FM
2
FM
1
BO
3
FM
7
SW
8
RO
8
SW
7
RO
7
SW
7
RO
8
SW
9
RO
8
SW
7
RO
13
SW
12
RO
5
LS2
5
LS1
18
SW
19
RO
13
RO
12
SW
6
RO
7
SW
11
RO
11
SW
6
LS2
6
LS1
3
FM
2
BO
39
LS1
36
LS1
39
LS2
35
LS2
8
LS1
8
LS2
23
SW
22
RO
1
WS
13
DW
45
AW
31
JT
20
JT
12
MP
1
FM
1
FM
3
HL
1
SB
32
JT
38
KF
4
HL
1
SB
1
SB
41
GS
47
PO
29
SJ
30
SJ
12
SJ
15
RR
1
SB
22
DL
7
SG
6
AW
1
SB
18
BF
3
JL
3
OA
50mmø
3
JL
50mmø
1
CO
50mmø
2
CO
50mmø
3
OA
50mmø
3
LL
50mmø
3
GT
50mmø
1
HB
1
SM
200mmø
*
WC
260mmø
2
FM
2
HB
11
FM
6
KF
6
KF
6
KF
1
AE
150mmø
1
F
600mmø
11
SP
50mmø
1
WP
200mmø
1
SP
200mmø
1
WS
200mmø
2
WS
200mmø
1
SM
450mmø
1
SP
200mmø
80
DL
30
DL
4
KF
1
EL
3
HL
1
WS
200mmø
2
QM
200mmø
3
WS
3
WS
5
BO
55
PO
43
JT
32
JT
TOP (6) SIX TREES TO
BE PLANTED ONCE
ESSO ENTRANCE IS
RESOLVED WITH THE
CITY OF OTTAWA
100
DL
30
SG
51
DW
43
GS
33
MP
7
SW
4
RO
7
RO
5
FM
6
SW
6
RO
8
LS1
8
LS2
3
SW
BOULDER
CLUSTER
BOULDER
CLUSTER
1
GB
37
SG
45
DL
25
KF
24
KF
24
KF
24
KF
8
RR
33
SG
22
SG
24
SG
24
SG
24
SG
22
SG
13
KF
24
KF
24
SG
24
SG
20
FS
15
FS
25
KF14
JT
15
SJ
30
JT
32
SJ
16
JT
17
SJ
30
DL
1
FM
1
FM
2
FM
1
HL
1
HL
1
HL
1
HL
1
HL
2
HL
36
JT
32
JT
DRAWN BY:
CHECKED BY:
SCALE
DATE
PROJECT NO.
DRAWING NO.
PROJECT NORTH
STAMP
No. Revision Date By
ML
1 : 500
JAMES LENNOX
PROJECT
December 2017
PLOT SIZE ARCH-D
TREE CONSERVATION REPORT &
LANDSCAPE PLAN
L.1
ISSUED FOR SITE PLAN APPROVAL1 12/12/2017 ML
13-MIS-1333
DRAWING
PROPOSED PLANT LIST
KEY QTY. BOTANICAL NAME COMMON NAME SIZE CONDITION REMARKS
TREES
RM 5 Acer rubrum Red Maple 60mm ø B&B
FM 35 Acer x freemanii Freeman Maple 60mm ø B&B
HB 3 Celtis occidentalis Common Hackberry 60mm ø B&B
SB 11 Amelanchier canadensis Serviceberry 60mm ø B&B
GB 9 Ginkgo biloba 'Princeton Sentry' Princeton Sentry Ginkgo 60 mm ø B&B
HL 24 Gleditsia triacanthos 'Skyline' Skyline Honey Locust 60 mm ø B&B
WS 7 Picea glauca White Spruce 1800 mm ht. B&B
BC 3 Prunus serotina Black Cherry 60mm ø B&B
BO 8 Quercus macrocarpa Bur Oak 60mm ø B&B
JL 5 Syringa recticulata Japanese Tree Lilac 70mm ø B&B
EL 4 Ulmus japonica x wilsoniana Accolade Elm 50 mm ø B&B
'Morton'
SHRUBS
DW 64 Cornus alba 'Spaethii' Yellowedge Dogwood 800 mm ht. Potted 1000mm o.c.
RO 138 Cornus sericea Red Osier Dogwood 800 mm ht. Potted 1000mm o.c.
LS1 102 Cornus sericea Red Osier Dogwood 50-50mm ø Live Stake 1000 mm o.c.
SJ 151 Hypericum kalmianum Kalm's St. John's Wort 300 mm ht. Potted 800 mm o.c.
JT 303 Juniperus sabina 'Tamariscifolia' Tamarix Juniper 600 mm spr. Potted 1000 mm o.c.
MP 178 Pinus mugo 'Pumilio' Dwarf Mugo Pine 600 mm spr. Potted 1200mm o.c.
PO 211 Potentilla fruticosa 'Pink Beauty' Pink Beauty Potentilla 600 mm spr. Potted 800 mm o.c.
RR 60 Rosa rugosa Rugosa Rose 800 mm ht. Potted 800 mm o.c.
SW 138 Salix exigua Sandbar Willow 800 mm ht. Potted 1000mm o.c.
LS2 101 Salix exigua Sandbar Willow 20-50mm ø Live Stake 1000mm o.c.
FS 35 Sorbaria sorbifolia 'Sem' Sem False Spirea 600mm ht. Potted 1000mm o.c.
AW 58 Spiraea x bumalda Anthony Waterer Spirea 600 mm ht. Potted 1000 mm o.c.
Anthony Waterer'
GS 118 Spiraea x arguta Garland Spirea 600 mm ht. Potted 1000mm o.c.
PERENNIALS & GRASSES
BF 214 Festuca glauca Blue Fescue 50 mm plug Cell Pack 400 mm o.c.
DL 555 Hemerocallis 'Stella D'Oro' Stella D'Oro Day Lily 150 mm pot Potted 300 mm o.c.
KF 228 Calamagrostis 'Karl Forester' Karl Forester Grass 250 mm pot Potted 800 mm o.c.
SG 385 Panicum virgatum Prairie Fire Switch 250 mm pot Potted 800 mm o.c.
'Prairie Fire'
1. It is the responsibility of the appropriate contractor or official to report any errors, omissions
or discrepancies on this plan with actual site conditions to the Landscape Architect before
proceeding with construction.
2. The contractor is to notify all utility companies and authorities prior to any excavation and
ascertain locations of underground services.
3. The contractor is to reinstate all areas and items damaged as a result of construction
activity.
4. The contractor is to comply with all pertinent codes and by-laws.
5. The contractor is to maintain a positive surface run-off throughout the entire construction
period.
6. The Landscape Architect is not responsible for subsurface conditions.
7. The contractor is to identify all existing trees to remain on site with the Landscape Architect
prior to construction.
8. The contractor is to stake the proposed location of all plant material in conjunction with the
Landscape Architect prior to excavation.
9. Minimum distances for selected deciduous trees are as follows:
- Sidewalks 1.5m
- Public Streets 2.5m
- Underground Infrastructure 2.0m
10. All trees within 1m of underground utility trenches are to be excavated by hand.
11. Remove all protective wrapping from tree trunks after installation.
12. Staking of trees shall only be performed if necessary.
13. Ensure that mulch is pulled back a min. distance of 75mm from base of tree trunk.
14. Deciduous trees to be planted on private property 450mm inside of property line.
GENERAL NOTES:
KEY
QTY.
ARCHITECTS:
SURVEYORS:
CIVIL
ENGINEERS:
CLIENT:
CONSULTANTS
LOCATION PLAN
LEGEND
David Schaeffer Engineering Ltd.
120 Iber Road Unit 203
Stittsville Ontario K2S 1E2
Tel : (613) 836-7183
www.DSEL.ca
14 Concourse Gate, Suite 500
Nepean, Ont. K2E 7S6
Phone: (613) 727-0850 / Fax: (613) 727-1079
Email: [email protected]
PROPOSED DECIDUOUS TREE
PROPOSED CONIFEROUS TREE
PROPOSED DECIDUOUS SHRUB/
ORNAMENTAL GRASS
PROPOSED CONIFEROUS SHRUB
PROPOSED SHRUB / PERENNIAL
GROUPING
PROPOSED SOD
PROPOSED CREEK BANK SEED
MIXTURE
PROPOSED TREE PROTECTION FENCE
EXISTING TREE TO REMAIN
SITE
NTS
5734, 5754 HAZELDEAN ROAD AND
24 IBER ROAD
OTTAWA, ON
HUNTINGTON PROPERTIES
2L.1
DECIDUOUS TREE PLANTINGNTS
3L.1
CONIFEROUS TREE PLANTINGNTS
4L.1
SHRUB PLANTINGNTS
5L.1
TREE PROTECTION FENCE (TEMPORARY DURING CONSTRUCTION)NTS
EXISTING TREES TO REMAIN
KEY QTY. BOTANICAL NAME COMMON NAME SIZE CONDITION REMARKS
TREES
AE 1 Ulmus americana American Elm 150 mmø Good Off site, to remain
QM 1 Quercus macrocarpa Bur Oak 150-1400mmø Good Off site, to remain
F 1 Fraxinus sp. Ash 600mmø Good Off site, to remain
AF 2 Acer x freemanii Freeman's Maple 70 mmø Good Off site, to remain
CO 3 Celtis occidentalis Hackberry 50 mmø Good Off site, to remain
GT 3 Gleditsia triacanthos Honey Locust 50 mmø Good Off site, to remain
JL 3 Syringa reticulata Japanese Tree Lilac 50 mmø Good Off site, to remain
LL 3 Tilia cordata Littleleaf Linden 50 mmø Good Off site, to remain
RO 6 Quercus rubra Red Oak 50 mmø Good Off site, to remain
SM 2 Acer saccharum Sugar Maple 200-450mmø Good Off site, to remain
SP 13 Pinus sylvestris Scots Pine 50-200mmø Good Off site, to remain
WC * Thuja occidentalis White Cedar Hedge 50-100mmø Good Off site, to remain
WS 3 Picea glauca White Spruce 200mmø Good Off site, to remain
* Denotes numerous
SIZE
KEY
QTY.
APPROVED REFUSED
THIS ______DAY OF ____________________, 20_____
____________________________________________________
DERRICK MOODIE,
MANAGER, DEVELOPMENT REVIEW - WEST,
PLANNING, INFRASTRUCTURE AND ECONOMIC
DEVELOPMENT DEPARTMENT, CITY OF OTTAWA
JAMES B. LENNOX & ASSOCIATES INC.LANDSCAPE ARCHITECTS3332 CARLING AVE. OTTAWA, ONTARIO K2H 5A8Tel. (613) 722-5168 Fax. 1(866) 343-3942
1L.1
TREE CONSERVATION REPORT AND LANDSCAPE PLANSCALE 1:500