2
www.siemens.com/codereader Product Comments Article no. *) Hand-held reading systems SIMATIC MV320 Rugged industrial barcode and data matrix reader for data matrix codes with medium up to high contrasts; Communication with a host computer via USB or RS232 6GF3320-0HT01 SIMATIC MV325 BT Rugged industrial barcode and data matrix reader for data matrix codes with medium up to high contrasts; suitable for wireless communication with bluetooth radio interface; Communication with a host computer via USB 6GF3325-0HT01 SIMATIC MV340 Rugged industrial barcode and data matrix hand- held reader (even low-contrast codes) with USB cable; RS232 cable can be ordered separately as an option. 6GF3340-0HT01 For accessories, see ID 10 Catalog Power-DIO-RS232/422 cable Cables for communication module interface External ring lights (optional) SIMATIC MV420 devices Accessories PLC, power supply and external light PLC, PC, HMI Communication module (ASM) for further connection possibilities to the PLC, e.g. with PROFIBUS 8 6 4 3 2 1 for connection possibilities to the HMI and PLC, e.g. with PROFINET G_FS10_XX_00436 IE Connecting Cable Power-DIO-RS232/422 cable Cables for communication module interface External ring lights (optional) PLC, PC, HMI Communication module (ASM) for further connection possibilities to the PLC, e.g. with PROFIBUS 8 6 3 SIMATIC MV440 devices Accessories Lenses and protective tubes PLC, trigger, power supply and external light 2 7 1 for connection possibilities to the HMI and PLC, e.g. with PROFINET G_FS10_XX_00421 Power over Ethernet (PoE) IE Connecting Cable SCALANCE X108PoE 4 5 SIMATIC MV420 configuration SIMATIC MV440 configuration Siemens AG Industry Sector Sensors and Communication Postfach 48 48 90026 NÜRNBERG GERMANY Subject to change without prior notice Article no.: 6ZB5330-0BG02-0BA2 MP.R1.SC.0000.66.3.02 / Dispo 26107 BR 0913 1. SB 6 En Printed in Germany © Siemens AG 2013 The information provided in this brochure contains descriptions or charac- teristics of performance which in case of actual use do not always apply as described or which may change as a result of further development of the products. An obligation to provide the respective characteristics shall only exist if expressly agreed in the terms of contract. Availability and technical specifications are subject to change without prior notice. All product designations may be trademarks or product names of Siemens AG or supplier companies whose use by third parties for their own purposes could violate the rights of the owners. SIMATIC Ident SIMATIC code reading systems Portfolio overview Edition October 2013 Ordering overview Answers for industry. Industrial Security Siemens provides automation and drive products with industrial security functions that support the secure operation of plants or machines. They are an important component in a holistic industrial security concept. With this in mind, our products undergo continuous development. We therefore recommend that you keep yourself informed with respect to our product updates. Please find further information and newsletters on this subject at: http://support.automation.siemens.com To ensure the secure operation of a plant or machine it is also necessary to take suitable preventive action (e.g. cell protection concept) and to integrate the automation and drive components into a state-of-the-art holistic industrial security concept for the entire plant or machine. Any third-party products that may be in use must also be taken into account. Please find further information at: http://www.siemens.com/industrialsecurity © Siemens AG 2013

SIMATIC code reading systems - w3app.siemens.com 3 2 1 for connection ... MP.R1.SC.0000.66.3.02 / Dispo 26107 BR 0913 1. SB 6 En ... GP 2x2 (Type A) 4-wire, shielded TP installation

Embed Size (px)

Citation preview

Page 1: SIMATIC code reading systems - w3app.siemens.com 3 2 1 for connection ... MP.R1.SC.0000.66.3.02 / Dispo 26107 BR 0913 1. SB 6 En ... GP 2x2 (Type A) 4-wire, shielded TP installation

www.siemens.com/codereader

Product Comments Article no. *)

Hand-held reading systems

SIMATIC MV320 Rugged industrial barcode and data matrix reader for data matrix codes with medium up to high contrasts; Communication with a host computer via USB or RS232

6GF3320-0HT01

SIMATIC MV325 BT Rugged industrial barcode and data matrix reader for data matrix codes with medium up to high contrasts; suitable for wireless communication with bluetooth radio interface;Communication with a host computer via USB

6GF3325-0HT01

SIMATIC MV340 Rugged industrial barcode and data matrix hand-held reader (even low-contrast codes) with USB cable;RS232 cable can be ordered separately as an option.

6GF3340-0HT01

For accessories, see ID 10 Catalog

Power-DIO-RS232/422 cable

Cables for communication module interface

External ring lights(optional)

SIMATIC MV420 devicesAccessories

PLC, power supply and external light PLC, PC, HMI

Communication module (ASM)for further connection possibilities to the PLC, e.g. with PROFIBUS

8

6

4

3

21

for connection possibilities to the HMI and PLC, e.g. with PROFINET

G_F

S10

_XX

_004

36

IE Connecting Cable

Power-DIO-RS232/422 cable

Cables for communication module interface

External ring lights(optional)

PLC, PC, HMI

Communication module (ASM)for further connection possibilities to the PLC, e.g. with PROFIBUS

8

6

3

SIMATIC MV440 devicesAccessoriesLenses and protective tubes

PLC, trigger, power supply and external light

27

1

for connection possibilities to the HMI and PLC, e.g. with PROFINET

G_F

S10

_XX

_004

21

Power over Ethernet (PoE)

IE Connecting Cable

SCALANCE X108PoE

4

5

SIMATIC MV420 configuration

SIMATIC MV440 configuration

Siemens AGIndustry SectorSensors and CommunicationPostfach 48 4890026 NÜRNBERGGERMANY

Subject to change without prior noticeArticle no.: 6ZB5330-0BG02-0BA2MP.R1.SC.0000.66.3.02 / Dispo 26107BR 0913 1. SB 6 EnPrinted in Germany © Siemens AG 2013

The information provided in this brochure contains descriptions or charac-teristics of performance which in case of actual use do not always apply as described or which may change as a result of further development of the products. An obligation to provide the respective characteristics shall only exist if expressly agreed in the terms of contract. Availability and technical specifications are subject to change without prior notice.All product designations may be trademarks or product names of Siemens AG or supplier companies whose use by third parties for their own purposes could violate the rights of the owners.

SIMATIC Ident

SIMATIC code reading systemsPortfolio overview

Edition October 2013

Ordering overview

Answers for industry.

Industrial Security

Siemens provides automation and drive products with industrial security functions that support the secure operation of plants or machines. They are an important component in a holistic industrial security concept. With this in mind, our products undergo continuous development. We therefore recommend that you keep yourself informed with respect to our product updates. Please find further information and newsletters on this subject at: http://support.automation.siemens.com

To ensure the secure operation of a plant or machine it is also necessary to take suitable preventive action (e.g. cell protection concept) and to integrate the automation and drive components into a state-of-the-art holistic industrial security concept for the entire plant or machine. Any third-party products that may be in use must also be taken into account. Please find further information at: http://www.siemens.com/industrialsecurity

© Siemens AG 2013

Page 2: SIMATIC code reading systems - w3app.siemens.com 3 2 1 for connection ... MP.R1.SC.0000.66.3.02 / Dispo 26107 BR 0913 1. SB 6 En ... GP 2x2 (Type A) 4-wire, shielded TP installation

S I M AT I C c o d e r e a d i n g s y s t e m s o r d e r i n g o v e r v i e w

Product Comments Article no. *)

SIMATIC MV420 stationary code reading systems 1

MV420 SR-BBasic model MV420• Pre-configured basic model; incl. lens 6 mm ring lamp, red• Basic model body; without lens, without ring lamp

6GF3420-0AA20

6GF3420-0AX20

MV420 SR-P

Performance model MV420 (for very high read rates; includes multicode reading and ID-Genius algorithm)• Pre-configured performance model; incl. lens 6 mm,

ring lamp, red• Performance model body; without lens, without ring lamp

6GF3420-0AA40

6GF3420-0AX40

Lenskit • Lens 6 mm, aperture 5.6, incl. protective tube• Lens 16 mm, aperture 4, incl. protective tube

6GF3420-0AC00-0LK06GF3420-0AC00-1LK0

Protective tube replacement set

2 x protective tubes, 3 x O rings,8 x mounting screws, offset screwdriver 6GF3420-0AC00-2AA0

Built-in ring lamp• red• white• infrared

6GF3420-0AC00-1LT06GF3420-0AC00-2LT06GF3420-0AC00-3LT0

Mounting bracket MV420 WxHxD (mm): 40x54x44; thickness: 2 mm 6GF3420-0AC00-1AA0

Plug-in power supply (EU, US) Demo and storage mode (only office) 6GF3420-0AC00-1PS0

SIMATIC MV440 stationary code reading systems 2

MV440 SRMV440 HRMV440 UR

Resolution: 640 x 480 pixelsResolution: 1024 x 768 pixelsResolution: 1600 x 1200 pixels

6GF3440-1CD106GF3440-1GE106GF3440-1LE10

”Text-Genius” license 1) Plain text detection, OCR recognition 6GF3400-0SL01

”Text-Genius Plus” license 6) Plain text detection, OCR recognition, learning of new fonts 6GF3400-1SL01

“Veri-Genius” license 2) Verification, incl. calibration template 6GF3400-0SL02

“Pat-Genius” license 7)Object recognition (consists of: classification, position detection, presence check, completeness check, symbol recognition)

6GF3400-0SL03

Einbauringlicht

• red• infrared• white• green

6GF3440-8DA116GF3440-8DA416GF3440-8DA216GF3440-8DA31

Mounting bracket MV440 WxHxD (mm): 80x80x60; thickness: 4 mm 6GF3440-8CA01

Tri-plate WxHxD (mm): 80x80x60; thickness: 4 mm 6GF9002-7AD

Lenses and protective tube for SIMATIC MV440 7

Mini lenses 4) 6 mm, 1: 1.4; D = 32 mm, L = 37.5 mm 6GF9001-1BB01

8.5 mm, 1:1.5 PENTAX; D = 42 mm, L=47 mm, MOD = 0.2 m; not suitable for built-in ring lamp 6GF9001-1BE01

12 mm, 1:1.4 PENTAX; D = 29.5 mm, L = 35.7 mm, MOD = 0,25 m 6GF9001-1BL01

16 mm, 1:1,4 PENTAX; D = 29.5 mm, L = 37.2 mm, MOD = 0.25 m 6GF9001-1BF01

25 mm, 1:1.4 PENTAX; D = 29.5 mm, L = 38.9 mm, MOD = 0.25 m 6GF9001-1BG01

35 mm, 1:1.6 PENTAX; D = 29.5 mm, L = 41.4 mm, MOD = 0.35 m 6GF9001-1BH01

50 mm, 1:2.8 PENTAX; D = 29.5 mm, L = 38 mm, MOD = 0.9m 6GF9001-1BJ01

75 mm, 1:2,8 PENTAX; D = 34 mm, L = 63.6 mm, MOD = 0.7 m; not with D65 protective lens tube 6GF9001-1BK01

Intermediate ring set Rings: 0.5/1/5/10/20/40 mm; D = 31 mm, to reduce the operating distance or for reading at close range 6GF9001-1BU

Rings: 0.5/1/1 mm; D = 31 mm, to reduce the operating distance or for reading at close range 6GF9001-1BU01

Infrared filter 5) To be independent of daylight 6GF9001-2AD

Blue filter 5) Improves the reproduction of structures 6GF9001-2AE

Polarization filter 5) Reduction of metallic reflections 6GF9001-2AF

Daylight filter (UV-IR-Cut) Protects the camera sensor against light frequencies other than daylight (e.g. laser rays) 6GF3440-8EA1

Focal length doubler Increases the focal length by a factor of 2 6GF9001-1BV

Protective tube D65 Made of metal; IP67

• Glass front pane 6GF3440-8AC11

• Plastic front pane 6GF3440-8AC21

Protective tube D65 3) Housing an front pane: plastic; IP67 6GF3440-8AC12

Industrial Ethernet switches for Power over Ethernet (PoE) 5

SCALANCE X108PoE 6 x 10/100 Mbit/s electrical RJ45 ports 2 x 10/100 Mbit/s electrical RJ45 PoE ports 6GK5108-0PA00-2AA3

For further Industrial Ethernet switches for PoE, please refer to the IK PI Catalog under “Industrial Ethernet switches/Media converters”

External ring lamps 8

External ring lamp:

• Metal, IR, clear IP67, range of illumination 500 … 3000 mm, 24 Volt 6GF3400-0LT01-7BA1

• Metal, red, clear IP67, range of illumination 500 … 3000 mm, 24 Volt 6GF3400-0LT01-8BA1

Mounting plate For external ring lamps for coaxial mounting on the MV440 6GF3440-8CD01

Cable M12, unconnected end, 4-pole, not trailable, 10 m 6GF3440-8BC4

Adapter Cable

M12, 4-pole (light), M16 12-pole (MV400); M16, 12-pole (power IO RS232 cable); connects MV440 directly with the light;25 cm

6GF3440-8BD1

Cable power supply, IO-RS232 and external lighting 3

Power-IO-RS232 cable M16 pre-assembled at one end, other end unconnected, 10 m 6GF3440-8BA2

M16 pre-assembled at one end, other end unconnected, 30 m 6GF3440-8BA4

Cables 4

IE Connecting Cable from M12 (D-coded) to RJ45 2 m; for commissioning and test 6XV1871-5TH20

IE Connecting CableM12-180/IE FC RJ45 Plug-145 For commissioning/service/installation; 2 m ... 15 m 6XV1871-5T...

IE Connecting Cable M12-180/M12-180 For installation; 0,3 m … 15 m 6XV1870-8A…

Cables can be assembled by the user for any cable lengths or connector versions

IE FC TP Standard Cable GP 2x2 (Type A)

4-wire, shielded TP installation cable; sold by the meter; price/meter 6XV1840-2AH10

IE FC Stripping Tool Stripping tool for IE FC cables 6GK1901-1GA00

IE FC RJ45 Plug 180 IE FC RJ45 Plug 2x2, 180° cable outlet 6GK1901-1BB10-2AA0

IE FC M12 Plug PRO M12 plug connector for assembly in the field (D-coded IP65/67) 6GK1901-0DB20-6AA0

For further cables, see IK PI Catalog under “Cabling systems”

Cables for the communication module interface 6

Standard cable without communication modules

For the direct connection of MV440 to ASM456, RF160C/170C/180C/182C, 2 m ... 50 m; or as extension cable for 6GF3420-0AC00-2CB0

6GT2891-4F…

Adapter cable for communication modules

For the direct connection of MV420 to ASM 456, RF160C/170C/180C/182C; 2 m; can be extended with the cable 6GT2891-4F...

6GF3420-0AC00-2CB0

For communication modules, see ID 10 Catalog - chapter 6

1) Executable on MV440, firmware 3.0 or higher2) Executable on MV440, firmware 4.0 or higher3) Included in scope of delivery of MV440n4) MOD = minimum object distance5) External lighting (e.g. IR for infrared6) Executable on MV440, firmware V5.0 or higher7) Executable on MV440, firmware V6.0 or higher

*) You will find up-to-date ordering data on the Internet at: www.siemens.com/industrymall

Conditions of sales and delivery are available at: www.siemens.com/automation/salesmaterial-as/catalog/en/terms_of_trade_en.pdf

© Siemens AG 2013