31
p/n 2M-Z16955 Rev. B M671 131114 671 OWNERS MANUAL for SINGLE & DUAL SATELLITE COFFEE BREWER with ELECTRO-MECHANICAL CONTROL and EXTERNALLY HEATED SATELLITE SERVERS MODEL: 9121 9221 Includes: Installation Operation Use & Care Servicing Instructions Model 9121 Single Satellite Brewer Fax (707) 448-1521 2060 Cessna Drive, Suite 100 Phone: (707) 448-5151 Wunder-Bar www.wunderbar.com Vacaville, CA 95688 U.S.A

Single & Dual Satellite Brewer - 9121, 9221 · It also does not apply if the serial nameplate has been removed or unauthorized service personnel perform service. upon the limitations

  • Upload
    others

  • View
    1

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Single & Dual Satellite Brewer - 9121, 9221 · It also does not apply if the serial nameplate has been removed or unauthorized service personnel perform service. upon the limitations

p/n 2M-Z16955 Rev. B M671 131114

671

OWNERS MANUALfor

SINGLE & DUAL SATELLITE

COFFEE BREWERwith

ELECTRO-MECHANICALCONTROL

andEXTERNALLY HEATEDSATELLITE SERVERS

MODEL:91219221

Includes:

InstallationOperation

Use & CareServicing Instructions

Model 9121 Single Satellite Brewer

Fax (707) 448-1521

2060 Cessna Drive, Suite 100

Phone: (707) 448-5151

Wunder-Bar

www.wunderbar.com

Vacaville, CA 95688 U.S.A

Page 2: Single & Dual Satellite Brewer - 9121, 9221 · It also does not apply if the serial nameplate has been removed or unauthorized service personnel perform service. upon the limitations

NOTE: For your protection, please note that equipment in this shipment was carefully inspected and packaged by skilled personnel before leaving the factory.Upon acceptance of this shipment, the transportationcompany assumes full responsibility for its safe delivery.

IF SHIPMENT ARRIVES DAMAGED:1. VISIBLE LOSS OR DAMAGE: Be certain that any

visible loss or damage is noted on the freight billor express receipt, and that the note of loss or damage is signed by the delivery person.

2. FILE CLAIM FOR DAMAGE IMMEDIATELY: Regardless of the extent of the damage.

3. CONCEALED LOSS OR DAMAGE: if damage is unnoticed until the merchandise is unpacked, notify thetransportation company or carrier immediately, and

the delivery was made to you. Be sure to retain thecontainer for inspection.

incurred in transit. We will, however, at your request, supply you with the necessary documents to support your claim.

WARRANTY STATEMENT

SERVICE POLICY AND PROCEDURE GUIDEADDITIONAL WARRANTY EXCLUSIONS

SHIPPING DAMAGE CLAIMS PROCEDURE

1. Resetting of safety thermostats, circuit breakers, overload protectors, or fuse replacements.

2. All problems due to operation at voltages other than

correct voltage must be the customer’s responsibility.3. All problems due to electrical connections not made in

accordance with electrical code requirements andwiring diagrams supplied with the equipment.

4. Replacement of items subject to normal wear, to include such items as knobs and light bulbs. Normal maintenance functions including adjustment of thermostats, microswitches, and replacement of fuses and indicating lights are not covered under warranty.

6. All problems due to mineral/calcium deposits, or

considered a preventative maintenance function and is not covered by warranty.

All electrical equipment manufactured by BLOOMFIELD is warranted against defects in materials and workmanship for a period of (1 year labor, two year parts) from the date

purchaser, except that:a. airpots carry a 30 day parts warranty only.b. dispensers; i.e., tea and coffee carry a 90 days parts warranty only, excludes decanters.c. decanters are not covered by this warranty

THE FOREGOING OBLIGATION IS EXPRESSLY GIVEN IN LIEU OF ANY OTHER WARRANTIES, EXPRESSED OR IMPLIED, INCLUDING ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE, WHICH ARE HEREBY EXCLUDED.

BLOOMFIELD, LLC SHALL NOT BE LIABLE FOR INDIRECT, INCIDENTAL OR CONSEQUENTIAL DAMAGES OR LOSSES FROM ANY CAUSE WHATSOEVER.

This warranty is void if it is determined that upon inspection by an authorized service agency that the equipment has

It also does not apply if the serial nameplate has been

removed or unauthorized service personnel perform service.

upon the limitations in this warranty. Seller’s obligation under this warranty is limited to the repair of defects without charge

to the closest authorized service agency, transportation charges prepaid, for services.

principal cities.

This warranty is valid in the United States, Canada and void

or your food service equipment dealer; or, for information and other details concerning warranty, write to:

Service Parts Department

10 Sunnen Drive, St. Louis, MO 63143 Phone: (314) 678-6336... Fax: (314) 781-2714

7. Full use, care and manuals may or may not be sent with each unit, only a condensed version. Please visit our web site to download the full version.

agencies. 9. All labor shall be performed during normal working hours.

Overtime premium shall be charged to the customer.

warranted equipment. Any use of non-genuine

11. Installation, labor and job checkouts are not considered warranty.

12. Charges incurred by delays, waiting time or operating restrictions that hinder the service technicians abilityto perform services are not covered by warranty. This includes institutional and correctional facilities.

xi

Page 3: Single & Dual Satellite Brewer - 9121, 9221 · It also does not apply if the serial nameplate has been removed or unauthorized service personnel perform service. upon the limitations

TABLE OF CONTENTSThank You for purchasing this

Proper installation, professional

maintenance of this appliance will ensure that it gives you the very

This manual contains the

appliance in a manner which will

WARRANTY STATEMENT xiSPECIFICATIONS 1FEATURES & OPERATING CONTROLS 2PRECAUTIONS & GENERAL INFORMATION 4AGENCY APPROVAL INFORMATION 4INSTALLATION 5OPERATION 7CLEANING INSTRUCTIONS 10SERVICING INSTRUCTIONS 12

Delime the water tank 12Draining hot water tank 13Timer Adjustment 14Temperature Adjustment 15

TROUBLESHOOTING SUGGESTIONS 16EXPLODED VIEWS 17WIRING DIAGRAM 26

1

SPECIFICATIONS

671

2M

-Z16

955

Ow

ners

Man

ual 9

221

Dua

l Sat

ellit

e B

rew

er

22 1/16”560 mm

3 5/16”84 mm

6 3/8”162 mm 4 1/2”

114 mm

5 13/16”148 mm 16 15/32”

418 mm

5 1/4”133 mm

6 1/4”159 mm19 9/16”

497 mm

16 7/16”417 mm

LINE CORDLOCATIONON BASE

DIMENSION SHOWN IS WITHOUT STRAINERASSY, ALLOW ADDITIONAL 5 INCHES

OPTIONAL DRIP TRAY(P/N WS-3901)

WATER INLETON BASE

WATER LINEON BASE

19 5/32”486 mm

29 5/16”744 mm

IL2302a, M671

MODELVOLTS

Hz WATTS AMPS POWER CORD60 Hz 1ø

9221 120/208-240V 60 Hz 1ø 4700/6250 23/26A Requires 3-wire (L1, L2, N plus Gnd) cord - not provided

9121120/240V 3/W N

50/60 Hz 1ø3150 26.25/13.125

120V 165013.7

5-15P230V 3150 Requires 3-wire (L1, L2, N plus Gnd) cord - not provided

Page 4: Single & Dual Satellite Brewer - 9121, 9221 · It also does not apply if the serial nameplate has been removed or unauthorized service personnel perform service. upon the limitations

FEATURES AND OPERATING CONTROLS

2

Fig 1. SS-2 Satellite Brewing System Features & Operating Controls

671 2M-Z16955 O

wners M

anual 9221 Dual S

atellite Brew

er

IL2303a, M671

BREWCHAMBER(IN POSITION)

FUSE (BEHINDFRONT PANEL)

SALELLITE(IN POSITION)

HOT WATERFAUCET

WARMERSWITCHES

Page 5: Single & Dual Satellite Brewer - 9121, 9221 · It also does not apply if the serial nameplate has been removed or unauthorized service personnel perform service. upon the limitations

FEATURES AND OPERATING CONTROLS (continued)

Brewer

Brewing Controls

Bypass Nozzle

Heater Switch

Hot Water Faucet

Nameplate

System Switch (not shown)

Satellite Locator/Warmer

Warmer Switches

Brew Chamber Brew Chamber

Bypass Diverter

Satellite

Nameplate

Serving Faucet

Sight Glass

Drip Tray (optional)

Turns power to tank heater ON or OFF

brewer ON or OFF

3671

2M

-Z16

955

Ow

ners

Man

ual 9

221

Dua

l Sat

ellit

e B

rew

er

Page 6: Single & Dual Satellite Brewer - 9121, 9221 · It also does not apply if the serial nameplate has been removed or unauthorized service personnel perform service. upon the limitations

Operators of this appliance must be familiar with the appliance use,

Disconnect the brewer from electrical power before performing any

DO NOT splash or pour water over, onto or into any controls,

WARNING:SHOCK HAZARD

components must be

DO NOT open any access

warning can result in severe

CAUTION:BURN HAZARD

Surfaces of this brewer can

on contact

GENERAL INFORMATION AND PRECAUTIONS

4

AGENCY APPROVAL INFORMATION

671 2M-Z16955 O

wners M

anual 9221 Dual S

atellite Brew

er

671 2M-Z16955 O

wners M

anual 9221 Dual S

atellite Brew

er

Page 7: Single & Dual Satellite Brewer - 9121, 9221 · It also does not apply if the serial nameplate has been removed or unauthorized service personnel perform service. upon the limitations

671

2M

-Z16

955

Ow

ners

Man

ual 9

221

Dua

l Sat

ellit

e B

rew

er

5

INSTALLATION INSTRUCTIONS

INSTALL LEGS

LEVEL THE UNIT

PLUMBER’S INSTALLATION INSTRUCTIONSIMPORTANT:

IMPORTANT:

NOTE:

NOTE:

ELECTRICIAN’S INSTALLATION INSTRUCTIONS

NOTE:To enable the installer to make

minimize installation time, these

CAUTION:UNSTABLEEQUIPMENT HAZARD

Failure to properly install thefeet can result in movement of the brewer, which can cause

Fig. 2 Adjustable Legs

CAUTION:SHOCK HAZARD

Brewer must be properly

671

2M

-Z16

955

Ow

ners

Man

ual 9

221

Dua

l Sat

ellit

e B

rew

er

SCREW INTOBREWERFRAME

ADJUSTFORHEIGHT

ATTACHRUBBERFEETIL2304

Page 8: Single & Dual Satellite Brewer - 9121, 9221 · It also does not apply if the serial nameplate has been removed or unauthorized service personnel perform service. upon the limitations

INSTALLATION INSTRUCTIONS (continued)

6

IMPORTANT:

IMPORTANT:Complete water line installation before connecting brewer to

MAKE SURE THE FRONT PANEL “HEATER ON/OFF” SWITCH IS IN THE OFF POSITION BEFORE CONNECTING BREWER TO ELECTRICAL POWER.DO NOT turn the HEATER ON/OFF switch on until the water

operate unless the appropriate

ON

INITIAL SET-UP INSTRUCTIONS

Be sure HEATER ON/OFF switch is OFF, then press

Press HEATER ON/OFF switch ON

the water temperature reaches the brew temperature set

operate unless the appropriate SATELLITE WARMER

671 2M-Z16955 O

wners M

anual 9221 Dual S

atellite Brew

er

671 2M-Z16955 O

wners M

anual 9221 Dual S

atellite Brew

er

Page 9: Single & Dual Satellite Brewer - 9121, 9221 · It also does not apply if the serial nameplate has been removed or unauthorized service personnel perform service. upon the limitations

671

2M

-Z16

955

Ow

ners

Man

ual 9

221

Dua

l Sat

ellit

e B

rew

er

7

GETTING STARTED

START-UPPress POWER SWITCH (back of brewer) to ON. Brewer water

HEATER ON/OFF switch to ON

OPERATING INSTRUCTIONS

Fig. 3 Control Panel

STARTBREW

STARTBREW

STOPBREW

STOPBREW

1 1/2 GAL

1 GAL

1 1/2 GAL

1 GAL

VOLUMESELECT

VOLUMESELECT

READY TOBREW

HEATERON / OFF

IL2305, M671

671

2M

-Z16

955

Ow

ners

Man

ual 9

221

Dua

l Sat

ellit

e B

rew

er

Page 10: Single & Dual Satellite Brewer - 9121, 9221 · It also does not apply if the serial nameplate has been removed or unauthorized service personnel perform service. upon the limitations

OPERATING INSTRUCTIONS (continued)

Fig. 4 Operating Controls

Fig. 5 Brew Basket

CAUTION:BURN HAZARD

BREWING COFFEE

Press VOLUME SELECT switch to 1 GAL or 1-1/2 GAL.

Press either the right or left START BREW

the BREW STOP

STARTBREW

STARTBREW

STOPBREW

STOPBREW

1 1/2 GAL

1 GAL

1 1/2 GAL

1 GAL

VOLUMESELECT

VOLUMESELECT

READY TOBREW

HEATERON / OFF

IL2305, M671

IL2306

671 2M-Z16955 O

wners M

anual 9221 Dual S

atellite Brew

er

671 2M-Z16955 O

wners M

anual 9221 Dual S

atellite Brew

er

Page 11: Single & Dual Satellite Brewer - 9121, 9221 · It also does not apply if the serial nameplate has been removed or unauthorized service personnel perform service. upon the limitations

671

2M

-Z16

955

Ow

ners

Man

ual 9

221

Dua

l Sat

ellit

e B

rew

er

OPERATING INSTRUCTIONS (continued)

WATER FLOW

INLET

BREW AND BYPASS

HOT WATER FAUCET

brewers have two

systems sharing a common

by the hot water tank, but

NOTE:Use of the hot water faucet

excessive use of the faucet

IL2307

671

2M

-Z16

955

Ow

ners

Man

ual 9

221

Dua

l Sat

ellit

e B

rew

er

Page 12: Single & Dual Satellite Brewer - 9121, 9221 · It also does not apply if the serial nameplate has been removed or unauthorized service personnel perform service. upon the limitations

PROCEDURE: Clean Coffee Brewer

Bristle Brush

CLEANING INSTRUCTIONS

10

CLEANING INSTRUCTIONS

CAUTION:BURN HAZARD

temperatures of coffee are

Hot coffee will cause serious

IMPORTANT:DO NOT use steel wool, sharp

the brewer, brew baskets or

DO NOT immerse or submerge

671 2M-Z16955 O

wners M

anual 9221 Dual S

atellite Brew

er

671 2M-Z16955 O

wners M

anual 9221 Dual S

atellite Brew

er

Page 13: Single & Dual Satellite Brewer - 9121, 9221 · It also does not apply if the serial nameplate has been removed or unauthorized service personnel perform service. upon the limitations

671

2M

-Z16

955

Ow

ners

Man

ual 9

221

Dua

l Sat

ellit

e B

rew

er

PROCEDURE: Clean Satellite

Soft Clean Cloth, Bucket

CAUTION:BURN HAZARD

temperatures of coffee

Hot coffee will cause

IMPORTANT:DO NOT submerge satellite in

IMPORTANT:DO NOT use steel wool, sharp

Sight Glass

11

CLEANING INSTRUCTIONS (continued)67

1 2

M-Z

1695

5 O

wne

rs M

anua

l 922

1 D

ual S

atel

lite

Bre

wer

IL2308

Page 14: Single & Dual Satellite Brewer - 9121, 9221 · It also does not apply if the serial nameplate has been removed or unauthorized service personnel perform service. upon the limitations

SERVICING INSTRUCTIONSCAUTION:CHEMICAL BURN HAZARD

Deliming chemicals may be

IMPORTANT: DO NOT spill,

solution into or over any internal

IMPORTANT: DO NOT allow any internal components to come into contact with the

keep all internal components

NOTE:

PROCEDURE: Delime the Water Tank

Protective Gloves, Goggles & Apron

Bristle Brush, Bottle BrushLarge Sink (or other appropriate work area)

12

671 2M-Z16955 O

wners M

anual 9221 Dual S

atellite Brew

er

671 2M-Z16955 O

wners M

anual 9221 Dual S

atellite Brew

er

Page 15: Single & Dual Satellite Brewer - 9121, 9221 · It also does not apply if the serial nameplate has been removed or unauthorized service personnel perform service. upon the limitations

671

2M

-Z16

955

Ow

ners

Man

ual 9

221

Dua

l Sat

ellit

e B

rew

er

SERVICING INSTRUCTIONS (continued)

DRAINING HOT WATER TANK

CAUTION:HOT WATER,

NOTE: Normally, silicone

13671

2M

-Z16

955

Ow

ners

Man

ual 9

221

Dua

l Sat

ellit

e B

rew

er

Page 16: Single & Dual Satellite Brewer - 9121, 9221 · It also does not apply if the serial nameplate has been removed or unauthorized service personnel perform service. upon the limitations

SERVICING INSTRUCTIONS (continued)CAUTION:SHOCK HAZARD

Disconnect brewer from electric power before opening the

TIMER ADJUSTMENT

Satellite or other container to calibrate volume

OFF. Turn POWER switch on back of brewer OFF.

NOTE:

Turn CLOCKWISE to increase time; Turn COUNTER-CLOCKWISE

ON. PressHEATER ON/OFF switch to ON.

14

SECONDS

1/16 TURNMAXIMUM

500187IL2550

671 2M-Z16955 O

wners M

anual 9221 Dual S

atellite Brew

er

671 2M-Z16955 O

wners M

anual 9221 Dual S

atellite Brew

er

Page 17: Single & Dual Satellite Brewer - 9121, 9221 · It also does not apply if the serial nameplate has been removed or unauthorized service personnel perform service. upon the limitations

671

2M

-Z16

955

Ow

ners

Man

ual 9

221

Dua

l Sat

ellit

e B

rew

er

SERVICING INSTRUCTIONS (continued)

15

CAUTION:SHOCK HAZARD

Live electrical circuits are

NOTE:Optimum brewing temperature

IMPORTANT:A mechanical thermostat will maintain temperature within

NOTE:

TEMPERATURE ADJUSTMENT

Satellite or other container to calibrate volume

OFF. Turn POWER switch on back of brewer OFF.

Turn CLOCKWISE to increase temperature Turn COUNTER-CLOCKWISE

ON. Press HEATER ON/OFF switch to ON.

6.

IL1606

671

2M

-Z16

955

Ow

ners

Man

ual 9

221

Dua

l Sat

ellit

e B

rew

er

Page 18: Single & Dual Satellite Brewer - 9121, 9221 · It also does not apply if the serial nameplate has been removed or unauthorized service personnel perform service. upon the limitations

16

TROUBLESHOOTING SUGGESTIONS

DESCRIPTION OF PROBLEM POSSIBLE CAUSE SUGGESTED REMEDY

No lights or heat Unit not plugged in or circuit breaker tripped Restore electric power

No heat

Power switch OFF Turn power switch ON

Hi-limit safety tripped Allow brewer to cool, verify water level, reset hi-limit

Thermostat damaged Replace thermostatDamaged hi-limit safety Replace hi-limitDamaged heater switch Replace heater switchDamaged heating element Replace heating elementWater level probe corroded Clean water level probePoor ground connection Verify ground connectionDirt in inlet valve or valve damaged Replace inlet valveBrew valve damaged Replace brew valveTank water boiling Adjust or replace thermostat

used. per brewChamber discharge hole plugged Clean brew chamberTimer not set properly Set timer

Check with coffee supplier for recommended grind and quantity

Heats slowConnected to wrong voltage Verify supply voltageScale build-up on heating elements De-lime hot water tankDamaged heating element Replace element

Brewer must be operated on a dedicated water line. Other equipment on line may be robbing water volume.

Plugged water line strainer Clean strainer

No heat to satelliteWarmer switch not on Turn warmer switch onDamaged element or wiring Replace as required

Poor coffee quality replace cartridges regularly. Use a quality coffee with a consistent roast. Use proper grind and amount of coffee per brew.

671 2M-Z16955 O

wners M

anual 9221 Dual S

atellite Brew

er

671 2M-Z16955 O

wners M

anual 9221 Dual S

atellite Brew

er

Page 19: Single & Dual Satellite Brewer - 9121, 9221 · It also does not apply if the serial nameplate has been removed or unauthorized service personnel perform service. upon the limitations

671

2M

-Z16

955

Ow

ners

Man

ual 9

221

Dua

l Sat

ellit

e B

rew

er

17

SATELLITE EXPLODED VIEW & PARTS LISTSATELLITE MODEL 9440

P/N: BLSRLH 74337 Rev. D 02/12/04

4.1

4.2

4.7

4.6 4.4 4.54.9 4.8

PART OFITEM 4

4 PL

2 PL

2

3

9

4

5

76

810

111

IL1855b

671

2M

-Z16

955

Ow

ners

Man

ual 9

221

Dua

l Sat

ellit

e B

rew

er

SATELLITE ASSEMBLY 9440Fig No Part No Quantity Description

1 D7-76657 1 WELDMENT SATELLITE ASSY2 2L-73863 1 TANK LID ASSY, SRL-DP3 2R-74313 1 HANDLE FAUCET GUARD4 2U-76577 1 FAUCET & SHANK ASY

4.1 2V-Z15411 1 FAUCET ESP ULTEM HI TEMP4.2 2U-71460 1 SEAT CUP TEA DISP FAUCET4.4 2C-84393 1 HEX NUT-SPOUT VALVE4.5 2C-H2016 1 WASHER-C-TOMLINSON4.6 2A-84395 1 SHANK-FAUCET4.7 2U-84396 1 SHANK ASSY FAUCET4.8 2C-84489 1 WASHER-FIBER4.9 2A-84488 1 FERRULE-VALVE SHANK5 D7-74539 1 ASSY SIGHT GAUGE HOUSING6 D7-74300 1 BRKT SIGHT GAUGE7 D7-74354 1 TUBE SIGHT GAUGE8 2K-70130 1 ELBOW SPRAYER9 2C-76008 4 SCREW 8X1/2 PAN PH DRILL

10 2C-76007 2 SCREW 8AX1/2 SS TR PH SMS11 2M-74342 1 DECAL SRL-H SATELLITE FRO

Page 20: Single & Dual Satellite Brewer - 9121, 9221 · It also does not apply if the serial nameplate has been removed or unauthorized service personnel perform service. upon the limitations

IL2309, PL671

EXPLODED VIEW 9221 CABINET AND EXTERIOR COMPONENTS671 2M

-Z16955 Ow

ners Manual 9221 D

ual Satellite B

rewer

671 2M-Z16955 O

wners M

anual 9221 Dual S

atellite Brew

er

Page 21: Single & Dual Satellite Brewer - 9121, 9221 · It also does not apply if the serial nameplate has been removed or unauthorized service personnel perform service. upon the limitations

671

2M

-Z16

955

Ow

ners

Man

ual 9

221

Dua

l Sat

ellit

e B

rew

er

PARTS LIST : 9221 CABINET AND EXTERIOR COMPONENTS67

1 2

M-Z

1695

5 O

wne

rs M

anua

l 922

1 D

ual S

atel

lite

Bre

wer

March 11, 2013

Model: Dual Satelite Brewers, Cabinet & Exterior CompFig No. Part Number Qty Description

1 2K-300102 1 STRAIN RELIEF 1NPT.375-1.2 2C-35485 6 NUT 1/4-20 HEX FINISHED S3 WS-50131 1 TERM BLK KIT-3 POLE .85AMP4 D7-76588 1 BRKT THERMOSTAT5 2C-46672 1 LUG GROUND SOLDERLESS 6-16 2C-35736 1 NUT 8-32 HEX KEPS MS GREE7 2C-70405 6 SCREW 6-32X1/4 PH RD HD M8 2N-70091UL 2 ELEM WARMER 120V 100W9 2E-306865 1 CONTROL LIQ LEVEL 208/24010 2C-70866 2 SCREW 6-32X7/8 PH PAN HD11 D7-71220 2 RETAINER WARMER ELEMENT12 D7-76583 1 TANK SUPPORT13 2I-72215 2 GASKET SPRAY HEAD 1.5 ID14 A6-72727 2 SPRAY HEAD DISC EMBOSSED15 2A-73098 4 LEG 4 BLK PLASTIC W/FLAN16 2A-73107 4 FEET RUBBER BLACK17 2M-Z16267 1 GRAPHIC CONTROL PANEL18 D7-76631 2 BRKT TANK SUPPORT TOP19 2E-74620 2 SWITCH LIGHTED SP OFF MOM20 2E-74621 2 SWITCH DP ON MOM OFF 10A21 2C-73457 25 NUT 8-32 HEX HEAD KEPS MS22 2E-74622 2 SWITCH DP ON NONE ON 10A23 2E-72395 1 SWITCH ROCKER 250V 20A AM24 2E-74098 1 SWITCH 2 POLE 50A 50/60HZ25 D7-76573 1 HOUSING LOWER26 D7-76589 1 COVER TOP HOUSING27 D7-76587 1 PANEL FRONT28 D7-76584 1 PLATE BOTTOM ASSY29 D7-Z16271 1 BASE WRAP30 2P-74623 2 TIMER FULL 2/3 1/331 D7-74327 1 WARMER BASE ASSY32 D7-WL0331 1 HOUSING UPPER ASSEMBLY33 2E-74382 2 SWITCH ON OFF VISIROCKER(35 2L-72387M 2 BREW CHAMBER MOLDED BLACK36 D7-76652 2 CHAMBER BREW ASSY36a D7-76651 2 BRKT BYPASS PLASTIC BREW41 2J-70644 1 LIGHT PILOT GREEN 250V 1/42 2E-37728 1 CONTACTOR 2P 240V 35A RES43 2I-73885 1 SHEILD DRIP CONTACTOR44 D7-74719 2 GUIDE SATELLITE 9441 944245 2C-70049 2 SCREW #8-32X1/2 PAN HD PH46 2A-73362 2 SPACER .375 OD .250 L .1747 D7-76590 2 BRKT TIMER48 2V-74427 1 SOLENOID SINGLE 120V 1.049 2C-73205 2 SCREW 4MMX6MM SL PAN MS S50 D7-76592 2 STIFFENER BOTTOM PLATE51 2C-35496 4 WASHER FLAT SS #4 .312OD

Page 22: Single & Dual Satellite Brewer - 9121, 9221 · It also does not apply if the serial nameplate has been removed or unauthorized service personnel perform service. upon the limitations

EXPLODED VIEW 9221 INTERIOR COMPONENTS

20

671 2M-Z16955 O

wners M

anual 9221 Dual S

atellite Brew

er

IL2310, PL671

671 2M-Z16955 O

wners M

anual 9221 Dual S

atellite Brew

er

Page 23: Single & Dual Satellite Brewer - 9121, 9221 · It also does not apply if the serial nameplate has been removed or unauthorized service personnel perform service. upon the limitations

671

2M

-Z16

955

Ow

ners

Man

ual 9

221

Dua

l Sat

ellit

e B

rew

er

PARTS LIST: 9221 INTERIOR COMPONENTS

21671

2M

-Z16

955

Ow

ners

Man

ual 9

221

Dua

l Sat

ellit

e B

rew

er

Model: Dual Satelite Brewers, Interior ComponentsFig No. Part Number Qty Description

1 D7-73778 4 RETAINING CLIP TANK LID3 2I-70147 1 GASKET TANK COVER4 2U-71061 1 FAUCET HOT WATER5 D7-76576 2 BRKT OUTLET VALVE6 A6-73521 1 PROBE ASSY WATER LEVEL7 2A-73532 1 SLEEVE WATER LEVEL PROBE8 2I-72390 1 GROMMET .375 ID TRANSLUCE9 F4-73978 1 TUBE SIL .312 ID X 30

10 2K-73152 2 ELBOW SPRAYER 1/4 ID11 D7-74309 1 TANK WELDMENT12 2N-74344UL 2 ELEM 240V/3000W13 2I-73309 2 GASKET TANK HEATER14 2A-74343 1 TUBE FILL 90 DEGREE15 2T-73312 1 THERMO HI LIMIT DBL POLE16 D7-76586 2 TANK/LID ASSY17 D7-74630 2 TUBE SIL .50 ID X 4.2518 2K-70103 2 ELBOW OUTLET19 2A-73384 4 TUBE SPRAY HEAD 2 3/8 LG20 A6-73537 1 TUBE SIL .312 ID X 9 LG21 2V-73388 2 VALVE ADJUST WATER OUTLET22 2C-72148 1 WASHER LOCK 1/2 ID INT SE23 2C-35485 1 NUT 1/4-20 HEX FINISHD SS24 2C-76007 4 SCREW 8AX1/2 SS TR PH SMS25 WS-8512-51 1 THERMO CNTRL,W-WSHR/SCREW26 D7-73414 1 SHIELD HI-LIMIT27 2C-73415 2 NUT 6-32 HEX 1.00 LG ALUM28 2G-73571 2 INSERT SPRAY HEAD29 2C-33926 2 WASHER FLAT #8 SS .38 O.D30 2C-44355 2 WELD SCREW 6-32X1/4 NELSO32 2A-76574 2 TUBE BYPASS33 2A-76582 2 FTG TEE REDUCING BRASS34 D7-76773 2 TUBE SIL .312 ID X 1.535 D7-74433 3 TUBE SIL .312 ID X 6 LG

March 11, 2013

Page 24: Single & Dual Satellite Brewer - 9121, 9221 · It also does not apply if the serial nameplate has been removed or unauthorized service personnel perform service. upon the limitations

EXPLODED VIEW 9121 CABINET AND EXTERIOR COMPONENTS

22

671 2M-Z16955 O

wners M

anual 9121, 9221 Dual S

atellite Brew

er

SK2651 Rev. - 5/8/13Model: 9121, Single Satellite Brewer

1

3

4

5

6

7

8

2

9

10

12

11

1314

1516

1718

32

33

34

35

1

1

3130

2324

22

See Detail A

21

1920

2928

27

26

25

36

37

38

39

40

671 2M-Z16955 O

wners M

anual 9121, 9221 Dual S

atellite Brew

er

Page 25: Single & Dual Satellite Brewer - 9121, 9221 · It also does not apply if the serial nameplate has been removed or unauthorized service personnel perform service. upon the limitations

671

2M

-Z16

955

Ow

ners

Man

ual 9

121,

922

1 D

ual S

atel

lite

Bre

wer

PARTS LIST : 9121 CABINET AND EXTERIOR COMPONENTS

23671

2M

-Z16

955

Ow

ners

Man

ual 9

121,

922

1 D

ual S

atel

lite

Bre

wer

Model 9121: Single Satelite Brewers, Main AssyFig No. Part Number Qty Description Applications

1 2C-76007 14 SCREW 8AX1/2 SS TR PH SMS2 D7-Z16698 1 TOP COVER3 2V-73388 1 VALVE ADJUST WATER OUTLET4 2A-73384 1 TUBE SPRAY HEAD 2 3/8 LG5 2A-76582 1 FTG TEE REDUCING BRASS6 2A-76574 1 TUBE BYPASS7 2A-73362 2 SPACER .375 OD .250 L .17

82E-46604

1CONTROL WATER LEVEL 120V

2E-306865 CONTROL LIQ LEVEL 208/240 120/240V, 230V9 2K-70103 1 ELBOW OUTLET

10 2K-73152 1 ELBOW SPRAYER 1/4 ID

112P-74623

1TIMER FULL 2/3 1/3 120/240V

2P-75123 TIMER 3 LEVEL 220V 230V12 2T-70109 1 THERMO CTRL BREWERS13 2M-Z16702 1 GRAPHIC PANEL

142J-72671

1LIGHT PILOT GREEN 125V 120V

2J-70644 LIGHT PILOT GREEN 250V 1/ 120/240V, 230V15 2E-72395 1 SWITCH ROCKER 250V 20A AM16 2E-74622 1 SWITCH DP ON NONE ON 10A17 2E-74621 1 SWITCH DP ON MOM OFF 10A18 2E-74620 1 SWITCH LIGHTED SP OFF MOM19 D7-Z17065 1 BRKT- TERMINAL BLOCK20 2E-37465 1 TERM BLOCK 3POLE 85AMP21 2C-46672 1 LUG GROUND SOLDERLESS 6-122 2E-Z14960 1 CONTACTOR, 40A23 Z1-70-07-0343 1 SWITCH GUARD24 2E-30330 1 SWITCH ON OFF TOGGLE 20A25 2A-73098 4 LEG 4 BLK PLASTIC W/FLAN26 2Q-75089 1 DOOR ACCESS PLASTIC

272V-74427

1SOLENOID SINGLE 120V 1.0 120/240V

2E-75760 SOLENOID SINGLE 220/240V 230V

282K-76118

1STRAIN RELIEF 120V

2K-300102 STRAIN RELIEF 1NPT.375-1. 120/240V, 230V29 2E-74382 1 SWITCH ON OFF VISIROCKER(30 2U-71061 1 FAUCET HOT WATER31 D7-Z16691 1 LOWER FRONT PANEL32 2I-72215 1 GASKET SPRAY HEAD 1.5 ID33 A6-72727 1 SPRAY HEAD DISC EMBOSSED34 D7-76652 1 BREW CHAMBER ASSY35 D7-74336 1 SATELLITE ASSY SRL-H36 D7-74719 2 GUIDE SATELLITE 9441 944237 D7-WL0365 1 BASE WARMER COVER ASSY

382N-70091UL

1ELEM WARMER 120V 100W 120/240V

2N-70635UL ELEM WARMER 100W 240V/85W 230V39 D7-71220 1 RETAINER WARMER ELEMENT40 2C-35485 1 NUT 1/4-20 HEX FINISHED SNI D7-Z17081 1 TUBE SIL .50ID X 8.5LNI 2E-41050 1 CORD SET 120V 14/3 5-15P 120V

Page 26: Single & Dual Satellite Brewer - 9121, 9221 · It also does not apply if the serial nameplate has been removed or unauthorized service personnel perform service. upon the limitations

EXPLODED VIEW CABINET AND EXTERIOR COMPONENTS

24

671 2M-Z16955 O

wners M

anual 9121, 9221 Dual S

atellite Brew

er

SK2652 Rev. - 5/8/13Model: 9121, Single Satellite Brewer Tank Assy

1

2

3

4

5

6

7

89

10

11

12

13

15

16

17

14

Detail A

671 2M-Z16955 O

wners M

anual 9121, 9221 Dual S

atellite Brew

er

Page 27: Single & Dual Satellite Brewer - 9121, 9221 · It also does not apply if the serial nameplate has been removed or unauthorized service personnel perform service. upon the limitations

671

2M

-Z16

955

Ow

ners

Man

ual 9

121,

922

1 D

ual S

atel

lite

Bre

wer

PARTS LIST : CABINET AND EXTERIOR COMPONENTS

25671

2M

-Z16

955

Ow

ners

Man

ual 9

121,

922

1 D

ual S

atel

lite

Bre

wer

Model 9121: Single Satelite Brewers, Tank AssyFig No. Part Number Qty Description Application

1 2I-72390 1 GROMMET .375 ID TRANSLUCE2 2A-74343 1 TUBE FILL 90 DEGREE3 D7-73414 1 SHIELD HI-LIMIT4 2T-73312 1 THERMO HI LIMIT DBL POLE5 2C-73415 2 NUT 6-32 HEX 1.00 LG ALUM

6A6-73521

1PROBE ASSY WATER LEVEL 120/240V, 230V

L2-75976 PROBE ASSY WATER LEVEL 1.61 120V7 2A-73532 1 SLEEVE WATER LEVEL PROBE8 D7-WL0347 1 TANK COVER ASSY9 2K-70103 1 ELBOW OUTLET10 2A-73384 1 TUBE SPRAY HEAD 2 3/8 LG11 2I-Z16545 1 TANK GASKET

12 2N-76571UL1

ELEM HEATIN 120V 1500W HW120V

2 120/240V, 230V13 2C-43914 1 TIE WIRE MTG STUD M4200-214 D7-Z16700 1 BRACKET, TANK TOP15 D7-Z16694 1 TANK SUPPORT BOTTOM16 2K-Y5093 3 BUSHING-SNAP #SB-1000-1217 D7-WL0346 1 TANK WELDMENT

Page 28: Single & Dual Satellite Brewer - 9121, 9221 · It also does not apply if the serial nameplate has been removed or unauthorized service personnel perform service. upon the limitations

26

WIRING DIAGRAM: 9221 DUAL SATELLITE BREWER

50/60

HZ

9221

MODEL

23/26.0

AMPS

4700/6250120/208-240

WATTSVOLTS

C C18 RED

WHITE

BLACK

BLAC

K

22

30

RED

12 G

A

8

RED

12 G

A

4

BLUE

12

GA

29

BLAC

K 12

GA

32

BLAC

K

31

BLUE

CO

NTA

CTO

R

WHITE

BLUE

25

WHITE20

WHITE20

19

BLACK17

12

WHI

TE

16

15

LIQUIDLEVELPROBE

BLACK14

WHITE13

WHITE10

WHITE10

RIGHTDUMP VALVE

LEFTDUMP VALVE

RED 12 GA9

RED

12 G

A

RED

12 G

A6

BLUE 12 GA5

HTG ELEMENT RIGHT208V 2750W240V 3000W

LEFTWARMER SWITCH

RIGHTWARMER SWITCH

RIGHTWARMER ELEMENT

LEFTWARMER ELEMENT

LOAD

LOAD

1

L2

LINE

1LI

NE 2

T1

BLACK(L1)

2

3

4

RED(L2)

WHITE(N)

HI-LIMITTHERMOSTAT

TERMINAL BLOCK

HTG ELEMENT LEFT208V 2750W240V 3000W

SWITCHPOWER

INLETVALVE

BOARDLIQUID LEVEL

THERMOSTAT

LEFT TIMER

BREWLIGHT

HEATERSWITCH

R. STOP BREWSWITCH

R. VOLUME SELECT SWITCH

21

BLACK23BLACK23

BLUE26

BLUE28

WHI

TE

20

7

1 BLACK12 GA

BRO

WN

12 G

A

2

BLUE

ORANGE

BLACK17

21

21

22

23 R. START BREW SWITCH

L. VOLUME SELECT SWITCH

L. START BREW SWITCH

L. STOP BREWSWITCH

BLUE

24LOAD

WIRE L2

L1

27

BLUE

RED

YELLOW

RED

BLACK

23

BLUE

3

BLAC

K

L2 L1

T2 T1

YELLOW 1G

1 1/2G 1 1/2G

1G

L1

WIRE L2

LOAD

RIGHT TIMER

INPU

T

NO

COMMAX

NC

BRO

WN

18 RED

11 ORANGE

TANKGROUND

GREEN33

22

JUMPER

2M-76634 REV D

IL2371

671 2M-Z16955 O

wners M

anual 9121, 9221 Dual S

atellite Brew

er

671 2M-Z16955 O

wners M

anual 9121, 9221 Dual S

atellite Brew

er

Page 29: Single & Dual Satellite Brewer - 9121, 9221 · It also does not apply if the serial nameplate has been removed or unauthorized service personnel perform service. upon the limitations

671

2M

-Z16

955

Ow

ners

Man

ual 9

121,

922

1 D

ual S

atel

lite

Bre

wer

WIRING DIAGRAM: 9121 SINGLE SATELLITE BREWER

27671

2M

-Z16

955

Ow

ners

Man

ual 9

121,

922

1 D

ual S

atel

lite

Bre

wer

18

30

8 4

29

32

31

CO

NTA

CTO

R

20

19

LIQUIDLEVELPROBE

14

10

10

DUMP VALVE

6

5

HTG ELEMENT RIGHT

120V 1500W

LOA

DLO

AD

1

L2

LIN

E 1

LIN

E 2

T1

BLACK(L1)

2

3

4

RED(L2)

WHITE(N)

HI-LIMITTHERMOSTAT

TERMINAL BLOCK

HTG ELEMENT LEFT

120V 1500W

SWITCHPOWER

INLETVALVE

BOARDLIQUID LEVEL

THERMOSTAT

BREWLIGHT

HEATERSWITCH

STOPBREWSWITCH

VOLUMESELECTSWITCH

21

23

26

28

7

1

2

21

21

STARTBREWSWITCH

24

27

RED

YELLOW

23

3

L2 L1

T2 T1

1 1/2G

1G

L1

WIRE L2

LOAD

TIMER

INP

UT

NO

CO

M

MA

XN

C

18

11

TANKGROUND

33

JUMPER

50/6013.73150120/2409121

HZMODEL AMPSWATTSVOLTS

2M-Z16953 REV (A)

L3

T3

17

1613

WARMER SWITCH

WARMER ELEMENT

GROUND

Page 30: Single & Dual Satellite Brewer - 9121, 9221 · It also does not apply if the serial nameplate has been removed or unauthorized service personnel perform service. upon the limitations

WIRING DIAGRAM: 9121-230V SINGLE SATELLITE BREWER671 2M

-Z16955 Ow

ners Manual 9121, 9221 D

ual Satellite B

rewer

CONTACTOR

L2L1

T2T1

L3

T3

STOPBREWSWITCHMOMNC

WARMER SWITCH

WARMERELEMENT

POWERSWITCHDPST

POWERSWITCHDPST

HILIMITSWITCH

HILIMITSWITCH

HEATERSWITCH

HEATERSWITCH

BREWLIGHT

THERMOSTAT

INLETVALVE

DUMPVALVE

230V

N

LIQUIDLEVELPROBE

BOARDLIQUID LEVEL

TANKGROUND HTG ELEMENT

LEFT120V 1500W

HTG ELEMENT RIGHT120V 1500W

STARTBREWSWITCHMOMNO

L1

WIRE L2

LOAD

TIMER

RED

YELLOW

VOLUMESELECTSWITCH

1 1/2G

1G

2M-Z17228 REV (-)

50/6013.731502309121

HZMODEL AMPSWATTSVOLTS

50/6013.330502308795

INPUT

JUMPER

NC

NO

COM

MAX

671 2M-Z16955 O

wners M

anual 9121, 9221 Dual S

atellite Brew

er

Page 31: Single & Dual Satellite Brewer - 9121, 9221 · It also does not apply if the serial nameplate has been removed or unauthorized service personnel perform service. upon the limitations

671

2M

-Z16

955

Ow

ners

Man

ual 9

121,

922

1 D

ual S

atel

lite

Bre

wer

NOTES67

1 2

M-Z

1695

5 O

wne

rs M

anua

l 912

1, 9

221

Dua

l Sat

ellit

e B

rew

er