0639-990/02o2013.09
Automatic sliding door
SLADescription
Original
0639-990-01---10o_2013.09.indd
SLA
0639-990/02oPage 2 of 41
Description
TABLE OF CONTENTS1 GENERAL REMARKS .................................................................................................3
1.1 Target group .......................................................................................................31.2 Document structure ...........................................................................................3
1.2.1 Basic documents ..................................................................................31.2.2 Option documents ................................................................................41.2.3 Workshop documents ...........................................................................41.2.4 Layout drawings ...................................................................................5
1.3 Auxiliary tools and service performances ..........................................................61.4 Abbreviations .....................................................................................................7
2 PRODUCT DESCRIPTION ..........................................................................................82.1 General remarks ................................................................................................8
2.1.1 SLAwithprofilesystemPSX,PSXP,PSA,PSF ...................................82.1.2 SLAwithprofilesystemPSW .............................................................10
2.2 Mounting versions ............................................................................................ 112.2.1 SLAwithprofilesystemPSX,PSXP,PSA .......................................... 112.2.2 SLAwithprofilesystemPSW .............................................................21
2.3 Normal operation .............................................................................................222.4 Options ............................................................................................................22
2.4.1 Emergency battery BATPA .................................................................222.4.2 MechanicalemergencyopeningMENO(FranceCO48) ...................222.4.3 LockingoftherunningcarriageLAVERI+LAVERI-FS ......................232.4.4 Door and lock monitoring TUWE ........................................................242.4.5 Manual unlocking inside HERI............................................................252.4.6 HERI monitoring .................................................................................262.4.7 Multi-pointlockingFLUVERI-MPSX,PSXP ........................................272.4.8 Multi-pointlockingFLUVERI-MPSW .................................................282.4.9 Floorlocking .......................................................................................292.4.10 Protection wing ...................................................................................30
2.5 Identification .....................................................................................................312.6 Technical data ..................................................................................................312.7 Applications limits ............................................................................................312.8 Wing weights in kg ...........................................................................................32
2.8.1 SLAwithprofilesystemPSX,PSXP ...................................................322.8.2 SLAwithprofilesystemPSA ..............................................................332.8.3 SLAwithprofilesystemPSF ..............................................................342.8.4 SLAwithprofilesystemPSW .............................................................35
2.9 Control and safety elements ............................................................................36
3 SAFETY .....................................................................................................................393.1 Safety devices .................................................................................................39
3.1.1 Reversing and stopping mechanism ..................................................393.1.2 Limitation of the force .........................................................................393.1.3 Residual current circuit breaker ..........................................................39
3.2 Safety regulations ............................................................................................403.2.1 Principles ............................................................................................403.2.2 Service................................................................................................403.2.3 Slidingwingsandfixedsidepanels ....................................................41
0639-990-01---10o_2013.09.indd
SLA
!
PSX PSA PSW3040
35≤5
44,5
20≥23
34,5
81≤4
65
92
89
≤8
≤8
≥25
PSF
20≤5
≤8
4040
35≤5
50
≤8
PSXP
0639-990/02oPage 3 of 41
Description
1 GENERAL REMARKSThe present description supplies a general summary of the sliding door installation SLA withtheprofilesystemsPSX,PSXP,PSA,PSFandPSW.Itisapplicableinconjunctionwiththedocumentsspecifiedhereafter.Together,thesedocumentsformthebasisforafaultless and safe operation of the installation.
1.1 Target groupThis description is destined for all the persons who are interested in the automatic sliding door SLA.
1.2 Document structure1.2.1 Basic documents
• Description 0639-990/02• Mountinginstructions 0639-990/12• Operatinginstructions 0639-990/22• Operatormanual 0639-991/02• Controlbooklet 0639-991/12
• MountinginstructionsSLAwithprofilesystemPSW 0639-990/32
• MountinginstructionsPSF 0623-990/42
0639-990-01---10o_2013.09.indd
SLA
!
0639-990/02oPage 4 of 41
Description
1.2.2 Option documents
• LockingofrunningcarriageLAVERI 0639-992/02• EmergencybatteryBATPA 0639-992/12• ManualunlockinginsideHERI 0639-992/22• MechanicalemergencyopeningMENO 0639-992/32• SetofwallplatesMAUPLA 0639-992/42• ProtectionwingSLA 0639-992/52• LockingofrunningcarriageLAVERIFailSafe 0639-992/62• DoorandlockmonitoringTUWE-VDSLAVERI-FS 0639-992/72• UnlockingsetLAVERIFailSafe 0639-992/82• AdaptersetLAVERIFailSecure 0639-992/92• DoorandlockmonitoringTUWE-VDSFLUVERI-M 0639-993/02
• HERImonitoring 0635-993/22• DoorandlockmonitoringTUWE-VDS 0635-999/42
• Mountingagainstceilingwithplate 0621-992/02• SidepanelPSXP 0621-992/12• SidepanelPSX 0621-999/06• Mountingagainstlintelwithangle 0621-999/11• Mountingagainstceilingwithangle 0621-999/15• Mountingagainstceilingwithtube 0621-999/19• Fan-lightPSX 0621-999/22
• SidepanelPSA 0623-992/02
1.2.3 Workshopdocuments
• Floorlocking 0621-990/02
• ProfilesystemPSX 0621-999/02• ListofprofilesPSX 0621-090
• ProfilesystemPSXP 0621-990/12• ListofprofilesPSXP 0621-092
• ProfilesystemPSA 0623-990/32• ListofprofilesPSA 0623-090
0639-990-01---10o_2013.09.indd
SLA
PSA
PSX
SLA
PSW
PSF
PSXP
0639-990/02oPage 5 of 41
Description
Wing Supportingprofile Sidepanel Pillar Number 2 x x standard P 03.20.01 2 x x reinforced P 03.20.02 2 x x without P 03.20.03 2 x - - P 03.20.04 2 - - - P 03.20.05 1 L x x standard P 03.20.06 1 L x x reinforced P 03.20.07 1 L x x without P 03.20.08 1 L x - - P 03.20.09 1 L - - - P 03.20.10 1 R x x standard P 03.20.11 1 R x x reinforced P 03.20.12 1 R x x without P 03.20.13 1 R x - - P 03.20.14 1 R - - - P 03.20.15 2 - - - P 03.20.40 2 x - - P 03.20.41 1 L - - - P 03.20.42 1 L x - - P 03.20.43 1 R - - - P 03.20.44 1 R x - - P 03.20.45 2 x x - P 03.30.01 2 x - - P 03.30.02 2 - - - P 03.30.03 1 L x x - P 03.30.04 1 L x - - P 03.30.05 1 L - - - P 03.30.06 1 R x x - P 03.30.07 1 R x - - P 03.30.08 1 R - - - P 03.30.09 2 x x - P 03.40.01 2 x - - P 03.40.02 1 L x x - P 03.40.03 1 L x - - P 03.40.04 1 R x x - P 03.40.05 1 R x - - P 03.40.06 2 - x - P 03.50.03 2 - - - P 03.50.04 1 L - x - P 03.50.07 1 L - - - P 03.50.08 1 R - x - P 03.50.11 1 R - - - P 03.50.12 2 x x standard P 03.60.01 2 x x reinforced P 03.60.02 2 x x without P 03.60.03 2 x - - P 03.60.04 2 - - - P 03.60.05 1 L x x standard P 03.60.06 1 L x x reinforced P 03.60.07 1 L x x without P 03.60.08 1 L x - - P 03.60.09 1 L - - - P 03.60.10 1 R x x standard P 03.60.11 1 R x x reinforced P 03.60.12 1 R x x without P 03.60.13 1 R x - - P 03.60.14 1 R - - - P 03.60.15
1.2.4 Layout drawingsThelayoutdrawingsarefilledinbythesalesagentonthebuildingsite.Theyareusedbytheprojectmanagementdepartmentfororderprocessing.Thelayoutdrawingsignedbythecustomerisalsoanintegralpartoftheorderconfirmation.
Fore
ign
win
gs
0639-990-01---10o_2013.09.indd
SLA
0639-990/02oPage 6 of 41
Description
1.3 AuxiliarytoolsandserviceperformancesTheauxiliarytoolsandserviceperformanceslistedhereafterareavailable,dependingontherespectivesituationandauthorization(pleaseaskyourdistributionagent):
• Companyportrait• Homepage• E-shop(authorization)• News• Info-NewsviaE-mail• Productbrochures• Productpresentation(PowerPoint)• Submissiontexts• Referencelist• Test/homologationcertificates• CADdata• Trainingcourses• Spareparts• Maintenancecontracts• Around-the-clockservice(notavai-lableinallthecountries)
Manufacturer:
Gilgen Door Systems AGFreiburgstrasse34CH-3150 SchwarzenburgPhone +41 31 734 41 11Fax [email protected]
Distribution agent/After-salesservice:
0639-990-01---10o_2013.09.indd
SLA
0639-990/02oPage 7 of 41
Description
1.4 AbbreviationsThefollowingabbreviationsareusedinconnectionwiththeSLAslidingdoorinstallation:
BAT-NOT Battery-assisted emergency opening MENO + BATPABATPA Emergencybattery(batteryunit)ENDAN Limit stopFLUVERI-M Multi-pointlockingmanualGEMO Gear motorHERI Manual unlocking insideHSK Main closing edgeLAUWA Running carriageLAVERI Locking of running carriageLAVERI-FS LockingofrunningcarriageFailSafe(unlocked)/FailSecure(locked)LB Clearance widthLH Clearance heightMAUPLA Wall platesMENO Mechanical emergency openingNSK Secondary closing edgeOKA Open contact outsideOKI Open contact insidePSA ProfilesystemA-rangePSF ProfilesystemF-rangefullglassPSX ProfilesystemX-rangePSXP ProfilesystemX-rangewithinterlockingPSW ProfilesystemW-range(Wiconaheat-insulated)RIMI Belt connection pieceSEIDE Side coverSTERE Control unitTUWE Door and lock monitoringULE Guide unitVdS German Association of mobiliar insurance companiesVERSW Covering angleZARI Toothed belt
0639-990-01---10o_2013.09.indd
SLA
140
LH
170
Y-Y
X-X
E
G
IK
B
AK=(LBx2)+100
50
213 350 125 199 7065
50D H JC GA F
LB
LHSK
PSX
PSA
PSF
LH14
014
0LH
Y X
21040 170
25
16
H XYL D MN
22050 170
140
LH
22050 170
28
11
PSXP
0639-990/02oPage 8 of 41
Description
2 PRODUCT DESCRIPTION2.1 Generalremarks2.1.1 SLAwithprofilesystemPSX,PSXP,PSA,PSF
Slidingdoordriveunitofmodularconstruction,inacovereddrivecasewithgearmotorGEMO,controlunitSTERE(230Vor115V)andvariousoptionalcontrolelements.Thedrive unit is equipped with an electric connection cable. The operating characteristics of the door can be determined via a control element (selection of the operating modes and settingoftheirrespectiveparameters).
A Wall plates MAUPLAB End stop ENDANC Covering angle VERSWD Gear motor GEMOE Control unit STEREF Emergencybattery* BATPAG Lockingofrunningcarriage* LAVERIH CarrierprofileI Toothed belt ZARIJ Guide unit ULEK Manualunlockinginside* HERIL Running carriage LAUWAM CoveringN Supportingprofile
AK Length drive caseLB Clearance widthLH Clearance height* Option
0639-990-01---10o_2013.09.indd
SLA
0639-990/02oPage 9 of 41
Description
Inordertoensurethemostoptimalfunctionalperformanceoftheslidingwings,itisre-commended to use the continuous bottom guide rail.
Incaseswherethisshouldnotbepossibleduetothestructuralsituation,afixpointguideshoe can be used.
Continuous bottom guide rail Fixpointguide
0639-990-01---10o_2013.09.indd
SLA
Wicona
Gilgen
Gilgen
Gilgen
Gilgen
0639-990/02oPage 10 of 41
Description
2.1.2 SLAwithprofilesystemPSW
PSW=Profil-SystemWicona• Thermallyinsulatedprofilesystem(withthermalseparation)basedontheWiconaprofi-
le system Wicstyle 65.• ThetechnicalprofiledocumentationisincludedintheWictypdirectivesrespectivelyin
the corresponding processing directives of Wicona.• HeatinsulatingcoefficientU=1,7...1,9W/(m2K)with24mminsulatingglass• Single-wingedandbi-partinginstallations• Withfixpointguideorcontinuousbottomguiderail• FLUVERIpossible• Protectionwingpossible
InterfaceWicona-Gilgen
Wiconafrontwithtransomprofile
with side panels
Wall openingwithouttransomprofile
without side panels
0639-990-01---10o_2013.09.indd
SLA
C
400=
=
400
C
89 0
/+3
140
LH
(51)
220
K
L
M
A
50 170
85,4
0/+
3
140
LH
(54,6)
210
40 170
K
L
M
PSA
PSXPSXP
0639-990/02oPage 11 of 41
Description
2.2 Mountingversions2.2.1 SLAwithprofilesystemPSX,PSXP,PSA
Warning:Thefasteningbasismustofferasufficientcarryingcapacityandbestable!Itisincumbentonthefittertoselecttheappropriatefixingmaterial!Distancebetweenthefasteningscrewsmax.400mm!
Attention:Anyfloorcoveringstobeinstalledatalaterdatemustbetakenintoaccount.Ifavailable,themeterelevationisrelevant.Admissiblehorizontaltolerance:1mmpermeter.Compensateanyunevennessofthefixingbasebymeansofbedplates!Avoidadistortionoftheprofiles.
A=Mountingagainstlintelsupportingandcarrierprofile
Fixingset:
K Carrierprofile-Supportingprofile(8p.) 0621-159*
L Supportingprofile-Lintel(8p.) 0621-160*
M Dependingonfixingbase: • Woodscrews(8p.) 0621-161* • Tubtara(8p.) 0621-166* • Dowelsconcrete(8p.) 0621-167* • Dowelsmortar(8p.) 0621-168*
* 2pieces: A > 3'200 mm
0639-990-01---10o_2013.09.indd
SLA
=
A
C200
200200
200200
200C=
LH
170
140
(31)
5851
LM
0639-990/02oPage 12 of 41
Description
Fixingset:
L Carrierprofile-Lintel(8p.) 0621-169*
M Dependingonfixingbase: • Woodscrews(8p.) 0621-161* • Tubtara(8p.) 0621-166* • Dowelsconcrete(8p.) 0621-167* • Dowelsmortar(8p.) 0621-168*
* 2pieces: A > 3'200 mm
B=Mountingagainstlintelcarrierprofile
0639-990-01---10o_2013.09.indd
SLA
max
. 100
LH
210
KLM
195
80
A
120
40 170
max
. 100
LH
220
KLM
195
50 170
PSA
PSXPSXP
0639-990/02oPage 13 of 41
Description
C=Mountingagainstlintelwithangle
K Fixingset:(2pieces:A>3'200mm) Carrierprofile-Supportingprofile(8p.) 0621-159
L Angleset: 0621-162 A = 0...2'899 mm 3 pieces A = 2'900...3'999 mm 4 pieces A = 4'000...5'099 mm 5 pieces A = 5'100...6'100 mm 6 pieces
M Dependingonfixingbase: • Woodscrews(8p.) 0621-170 • Tubtara(8p.) 0621-166 • Dowelsconcrete(8p.) 0621-167 • Dowelsmortar(8p.) 0621-168
0639-990-01---10o_2013.09.indd
SLA
80
A
100.
..170
LH
210
KL
M
140
30...60
120
40 170
100.
..170
LH
220
KL
M
140
30...60
50 170
PSA
PSXPSXP
0639-990/02oPage 14 of 41
Description
D=Mountingagainstceilingwithangle
K Fixingset:(2pieces:A>3'200mm) Carrierprofile-Supportingprofile(8p.) 0621-159
L Angleset: 0621-163 A = 0...2'899 mm 3 pieces A = 2'900...3'999 mm 4 pieces A = 4'000...5'099 mm 5 pieces A = 5'100...6'100 mm 6 pieces
M Dependingonfixingbase: • Woodscrews(8p.) 0621-170 • Dowelsconcrete(8p.) 0621-167
0639-990-01---10o_2013.09.indd
SLA
130
A
H17
0...1
'500
LH
210
140
K
L
M25
80
40 170
H17
0...1
'500
LH
220
140
K
L
M25
50 170
PSA
PSXPSXP
0639-990/02oPage 15 of 41
Description
E=Mountingagainstceilingwithtube
K Fixingset:(2pieces:A>3'200mm) Carrierprofile-Supportingprofile(8p.) 0621-159
L Tubeset: 0621-152
A H Pieces (mm) (mm)
0...3'999 0...749 3
4'000...5'099 0...749 4
5'100...6'100 0...749 5
0...3'999 750...1'500 4
4'000...5'099 750...1'500 5
5'100...6'100 750...1'500 6
M Dependingonfixingbase: • Woodscrews(8p.) 0621-170 • Dowelsconcrete(8p.) 0621-167
0639-990-01---10o_2013.09.indd
SLA
80
A
LH
210
K
L
M
140
70 ±5
22**
40 170
LH
220
K
L
M
140
70 ±5
50 170
PSA
PSXPSXP
140
1212
10*
22** 10*
22**10*
0639-990/02oPage 16 of 41
Description
F=Mountingagainstceilingwithplate
K Fixingset:(2pieces:A>3'200mm) Carrierprofile-Supportingprofile(8p.) 0621-159
L Setofplates: 0621-188 A = 0...2'899 mm 3 pieces A = 2'900...3'999 mm 4 pieces A = 4'000...5'099 mm 5 pieces A = 5'100...6'100 mm 6 pieces
M Dependingonfixingbase: • Woodscrews(8p.) 0621-170 • Tubtara(8p.) 0621-166 • Dowelsconcrete(8p.) 0621-167 • Dowelsmortar(8p.) 0621-168
Calculation clearance height in KDOSCompensation of the building tolerance
0639-990-01---10o_2013.09.indd
SLA
96
86
443427
176
143
62
42
14
LH14
0
170
15
5
40
A
210
5
9686
443427
186
153
72
52
14
LH14
0
170
15
50
220
PSA
PSXPSXP
0639-990/02oPage 17 of 41
Description
G=Self-supportingmountingwithwallplatesMAUPLA
Thickness
1 Set of wall plates 0639-102
Dependingonfixingbase:• ScrewsM10• Dowelsconcrete(6p.) 0630-263• Dowelsmortar(6p.) 0630-264
LengthofdrivemechanismA:• self-supportingmax.4'100mm only with side panel• withoutsidepanel only according to mounting versi-onsC,D,EorF
Thickness
LengthofdrivemechanismA:• self-supporting only according to mounting versions C,D,EorF
0639-990-01---10o_2013.09.indd
SLA
3540-041/..3540-042/..3540-043/..3540-044/..3540-046/..3540-047/..
2,43,02,43,03,03,0
1:61:61:61:61:61:6
2025202532,532,5
28L
M
70
TP 57
13
L
Y≤
480
X
M
K
≤ 48
0≤
480
≤ 48
0
0639-990/02oPage 18 of 41
Description
H=Self-supportingmountingwith"Pillarstandard"onlyprofilesystemPSX,PSXP
The pillars standard are used together with side panels. They are fastened sideways against the wall.
Inthefollowingcasesanadditionalsuspensionisrequired:• Drivemechanismlengthexceeding4'200mmIfatwo-piecefanlight(optional)isbeingused,thecenterpostofthefanlightisregardedas an additional suspension.
Forthefanlight'sglasspanel,thefollowingrequirementsareapplicable:• Maximumheightoffanlight1,5m• Max.weightperglasspanelforaninstallationwithoutauxiliarydevices;60kg(2per-sons)
• Max.weightperglasspanelforaninstallationwithauxiliarydevice;100kg(2persons)• Glasstypesanddimensionsaccordingtothefollowingchart:
Fan-light(option)
FixingsetSLA:
K Carrierprofile-Supportingprofile(8p.) 0621-159*
L Pillar standard 0621-164
M Dependingonfixingbase: • Woodscrews(14p.) 0621-173 • Tubtara(14p.) 0621-171 • Dowelsconcrete(14p.) 0621-172
* 2pieces:A>3'200mm
Designation
IV 24IV 24 temperedIV 24 coatedIV 24 coated temperedIV-VSG 24IV-VSG 24 coated
Max. length (m)
Max. length ratio Weight (kg/m2)
Art. no.
0639-990-01---10o_2013.09.indd
SLA
L
M
L
L
M
70
1040
239
13
57TP
944545
1013
LH
TP
35 14
97
57
K10
min
. 170
0639-990/02oPage 19 of 41
Description
I=Self-supportingmountingwith"Pillarreinforced"onlyprofilesystemPSX,PSXP
The pillars reinforced are used together with side panels. They are fastened at the bottom by means of base plates and on top by means of ceiling adapters. The length must be calculated fromthebareflooruptothebareceiling(intheeventofafalseceiling).
The ceiling adapter is screwed into the same grooeasthesupportingprofileadapter.Forthisreason,aminimumheightof170mmisrequi red between the upper edge of the suppor-tingprofileandtheceiling.Ifafanlightisprovided,thentheminimumheight between the upper edge of the suppor-tingprofileandtheceilingmustbe300mm.
In the following cases an additional suspension isrequired:• Drivemechanismlengthexceeding4'200mmIfatwo-piecefanlight(optional)isbeingused,thecenterpostofthefanlightisregardedas an additional suspension.
Forthefanlight'sglasspanel,thefollowingrequirementsareapplicable:• seetableinmountingversionH.
FixingsetSLA:
K Carrierprofile-Supportingprofile(8p.) 0621-159*
L Pillar reinforced 0621-165
M Dependingonfixingbase: • Woodscrews(8p.) 0621-170
* 2pieces:A>3'200mm
Ceiling adapter
Supporting profileadapter w
ithfanlight:m
in.300
0639-990-01---10o_2013.09.indd
SLA
0621-468/..
0621-469/..
LH
0639-990/02oPage 20 of 41
Description
ConnectionprofileforsidepanelonlyprofilesystemPSX,PSXP
Iftheinstallationiscarriedoutwithasidepanel,andprovidedthatthesupportingprofileisinstalledaccordingtothepreviouslymentionedassemblyversions,theconnectionprofilecanbeusedinsteadofthepillar(standard/reinforced).
Theconnectionprofilecanbeinstalledonthesideofthelintelorofthewall.Itslengthcorresponds to the clearance height LH.
0639-990-01---10o_2013.09.indd
SLA
HSK HSK
HSK HSK
0639-990/02oPage 21 of 41
Description
2.2.2 SLAwithprofilesystemPSW
2-winged
1-wingedopeningtotheleft(openingtotheright=mirror-inverted)
with/without fan-light
Connection to the Wicona front
Connection in the wall opening
Connection to the wall opening
Connection to the Wicona front
Connection in the wall opening
Connection to the wall opening
Wiconafront Wall opening
1-wingedopeningtotheleft(openingtotheright=mirror-inverted)
2-winged
with/without fan-light
0639-990-01---10o_2013.09.indd
SLA
0639-990/02oPage 22 of 41
Description
2.3 Normal operationThe door opening is performed automat. via impulse generator or manually by means of a push-button. The door is automat. closed as soon as the programmed hold-open time has expired.
2.4 Options2.4.1 Emergency battery BATPA
Withtheemergencybattery,thedoorcon-tinues to function normally during 15...30 minutes after a mains failure has occurred.The accelerations and the speed in the end positions of the sliding wings are reduced with regard to the mains-operated mode.
IntheoperatingmodeNIGHT,theinstalla-tion can be activated for one opening and closingmotionbymeansof:• Manualunlocking(actuateduringatleast5seconds)
• Keycommand.
Attention:Repeated activation of the installation might destroy the emergency battery.
2.4.2 MechanicalemergencyopeningMENO(FranceCO48)
Incaseofpowerfailureorfailureoftheemergencybattery(option)themechanicalemer-gency opening system triggers an immediate opening of the unlocked door. During every normalclosingprocedureoftheslidingdoor,arubbercableisstretched.Incaseofanemergency,thiscableopenstheslidingwingviaarunningcarriage.
Inthecaseofabi-partinginstallation,themovementistransmittedtothesecondslidingwing by means of the toothed belt ZARI.
0639-990-01---10o_2013.09.indd
SLA
0639-990/02oPage 23 of 41
Description
2.4.3 LockingoftherunningcarriageLAVERI+LAVERI-FS
Thelockingoftherunningcarriageismountedinthecarrierprofile(withintheareaoftheclosingedge).ItfeaturestwointerfaceswheretheBowdencablesoftwomanualunlo-cking mechanisms can be connected.The locking latch resp. the locking hook is engagedintotherunningcarriage(s),thuspreventing the sliding wings from being forced open.
LAVERI
Thelockingisbistable,e.g.thelockinglatchis held independently in the locked and unlocked position. The locking state is not confirmed.Correctlockingisnotchecked!
Behaviour in the event of a mains and batte-ryfailure:Door positionclosed lockedopen unlockedmoving unlockedclosed locked manuallly unlocked manually opened
LAVERIremains lockedremains unlockedremains unlockedis automatically locked upon manual clo-sing
Behaviour in the event of a mains and batte-ryfailure:
LAVERI-FS
Thelockingmechanismismono-stable,i.e.the locking hook is electrically maintained onlyinoneposition,whileitautomaticallydrops into the other position in the event of a mains failure. Whether the locking mecha-nism is locked or unlocked without mains power is determined by the way in which the locking hook has been installed.
Locking latch
Locking hook
Door positionclosed locked
open unlocked
moving unlocked
FailSafeunlocked Door remains closed.unlocked Door remains open.
unlocked Door slows down to a full stop.
FailSecureremains locked Door remains closed.locked After being manually closed,thedoorislocked.
locked Door slows down to a full stop. After being manually closed,thedoorislocked.
0639-990-01---10o_2013.09.indd
SLA
0639-990/02oPage 24 of 41
Description
2.4.4 DoorandlockmonitoringTUWE
ThedoorandlockmonitoringTUWEprovidesthefollowingtwo(separate)potential-freecontacts:• Doorclosed• Lockmonitoring
These two contacts are available for evaluation by customers (for example by an alarm system).Thesignal"Doorclosedandlocked"isgeneratedasaresultofaserialswit-ching of both contacts.
Note:Ifadditionallinkagesarerequired,e.g.thebridgingofanalarmduringanauthorized door opening or the inhibition of the opening elements (key-operatedimpulseswitch,badgereader,etc.)whilethealarmisactive,thesehavetobeprovidedbycustomers.Inthesecases,theopeningelements(key-operatedimpulseswitch,badgereader,etc.)mustbeconnectedviathealarm system.In the event of an authorized opening the door receives an OPEN command (potential-freecontact/makecontact)fromthealarmsystem.
The door and lock monitoring TUWE-VdS a lock monitoring unit tested by the VdS on thebasisonthedirectivesforburlaralarminstallations,withC-classratingundertheconditions of the environmental class II. VdS = Association of loss and damage insurance company(Germany).
• TUWE-VdS 0635-119 LAVERIstandard
• TUWE-VdSLAVERI-FS 0639-143 LAVERI-FS
• TUWE-VdSFLUVERI-MPSW 0621-275 FLUVERI-M ProfilesystemPSW
0639-990-01---10o_2013.09.indd
SLA
0639-990/02oPage 25 of 41
Description
2.4.5 ManualunlockinginsideHERI
The manual unlocking inside HERI can be locatedwithinthecarrierprofile,accordingtothe respective situation. It is connected with the locking of the running carriage LAVERI by means of a Bowden cable.
Pulling the manual unlocking handle causes the locking of the running carriage LAVERI to be actuated (the locking latch resp. the lockinghookreleasestheslidingwing(s).
FunctioninthemodeNIGHT:
Pull HERI < 5 s
> 5 s
Mains supply functioning
mechanicalunlocking,Keycom-mand(dooropens)mechanicalunlocking,Keycom-mand(dooropens)
Without mains supply With option BATPAmechanical unlocking
mechanicalunlocking,Keycom-mandafterWake-Up(dooropens)
Without mains supply Without option BATPAmechanical unlocking
mechanical unlocking
0639-990-01---10o_2013.09.indd
SLA
0639-990/02oPage 26 of 41
Description
2.4.6 HERImonitoring
The HERI monitoring can be used with the LAVERI. This option provides the following potential-freecontact:• Manualunlockingoperated.Thiscontactisavailableforevaluationbycustomers(forexamplebyanalarmsystem).
0639-990-01---10o_2013.09.indd
SLA
A
B
A 66
22
228
74 6 74 B
45
0639-990/02oPage 27 of 41
Description
2.4.7 Multi-pointlocking FLUVERI-MPSX,PSXPProfilesystemPSX,PSXP
• Two-wayinterlockingoftheslidingwings.• Concealedmountingintotheslidingwings.• Operationviakeyorrotary-typeknob(half-cy-linderfrominside,doublecylinderfrominsideandoutside,seeapplicationsheet P08.14.02).
• Unlockinglever(option).• DoorandlockmonitoringTUWE-VdS(opti-on).
• Merelymanualoperation.• Bottombolt(option)onlywithfixpointguide
shoe.
Bottombolt(option)onlyFLUVERI-M
Unlockinglever(option)
Reducedopeningwidth: FLUVERI-Mwithbottomboltandfixpointguide
0639-990-01---10o_2013.09.indd
SLA
A
B
B
A
50
0639-990/02oPage 28 of 41
Description
2.4.8 Multi-pointlocking FLUVERI-MPSWProfilesystemPSW
• Two-wayinterlockingoftheslidingwings.• Concealedmountingintotheslidingwings.• Operationviakeyorrotary-typeknob(doublecylinderfrominsideandoutside,seeapplica-tionsheetP08.14.03).
• Unlockinglever(option).• DoorandlockmonitoringTUWE-VdS(opti-on).
• Merelymanualoperation.• Bottombolt(option)onlywithfixpointguide
shoe.
Bottombolt(option)onlyFLUVERI-M
Unlockinglever(option)Reducedopeningwidth: FLUVERI-Mwithbottomboltandfixpointguide.
0639-990-01---10o_2013.09.indd
SLA
!
0639-990/02oPage 29 of 41
Description
2.4.9 Floorlocking
Withsingle-wingedandbi-partinginstallations,thefloorlockingcanbeusedinconnec-tionwiththefollowingprofilesystems:• PSX• PSXP• PSA
Thefloorlockingisattachedtotheplinthprofile(ontheinsideofthedoorwing).Itcon-sistsofthefollowingelements:• Floorlock ontheleftorrightside,forKabaorprofilecylinder Halfcylinder operableonlyfromtheinside(lockside) Double cylinder operable from inside and outside Cylinderdelivery bycustomers(cylindertypesandlengths:seeinstructions 0621-990/02Floorlocking)
• Housing powder-coatedblackRAL9005mattedoruntreated,for powder-coating in a shade matching the installation Attention: Anodizing(whethernaturalnorcolored)isnotrecommended (asthesurfacewouldresultunattractiveandblotchy)!• Distanceset dependingontheprofilesystem• Strikeplate ifwithfix-pointguideshoe• Closingcase ifwithcontinuousbottomguiderail
dependingontheversion:turn horizontally by 180°
Distance setThickness: 10mm=PSX,PSXP 20 mm = PSA
Closing case
Cylinder (by custo-mer)
HousingWidth = 126 mmHeight = 66 mmDepth = 41 mm
Floorlock
Strike plate
Continuous bottom guide rail
Fixpointguide
0639-990-01---10o_2013.09.indd
SLA
0639-990/02oPage 30 of 41
Description
2.4.10 Protectionwing
The protection wing can be ordered either as acompleteKitoronlyasafixingsetallo-wing to use a protection wing to be supplied by customers.
Preliminaryrequirementsforthemounting:• Withfixpointguide: Thefloorontheinsideofthedoormustbefinished.
• Withcontinuousbottomguiderail: The continuous bottom guide rail must be installed.
Thefloorontheinsideofthedoormustbefinished.
0639-990-01---10o_2013.09.indd
SLA
PSX,PSXP,PSF2'500 mm
160 kg1:6
PSA1'500 mm
110 kg1:6
0639-990/02oPage 31 of 41
Description
2.7 Applications limits
Attention:Themaximumratiobetweenthewingwidthandheightof1:6mustbeobserved in any case.
2.6 TechnicaldataPower transmissionNumber of revolutions toothed belt pulleyOperating voltage
Control voltagePower consumptionAmbient temperature
The unit may only be used in dry rooms
Toothed belt10...225 min-1
230VAC(+10%/-15%),50...60Hz,1A 115VAC(+10%/-15%),50...60Hz,2A24VDC(1A)120 W-15...+50 °C if the installation remains permanently connected to the mains supplymax. relative humidity 70 %
DriveunitMinimumlengthPSX,PSXP,PSA,PSFMinimum length PSWSliding wingClearance width LBMinimum wing widthMaximum wing heightMaximum wing weightHeightadjustmentDepthadjustmentWing speed
1wingL+R2 x LB + 100 mm2 x LB + 200 mm
700...2'000 mm700 mm
3'000 mm120 kg
±10 mm±15 mm
max.0,6m/s
bi-parting2 x LB + 100 mm2 x LB + 200 mm
900...3'000 mm450 mm
3'000 mm2 x 120 kg±10 mm±15 mm
max.0,6m/s
Side panelMax. widthMax. weightMax. ratio between glass width and height
2.5 IdentificationThe rating plate (including TÜV and EC identification)canbefoundinsidethedrivecase(onthedriveunitcovering).
0639-990-01---10o_2013.09.indd
SLA
90
0 -
483
22
24
26
28
31
26
29
31
34
37
31
34
36
39
43
32
35
38
41
46
37
41
44
48
53
40
44
47
51
56
33
36
39
42
46
1'
000
- 53
3 24
26
28
30
33
29
32
34
36
40
34
37
40
43
47
35
39
42
45
50
41
45
49
52
58
44
48
52
56
62
36
40
43
46
51
1'
100
- 58
3 26
28
30
32
36
31
34
37
39
43
36
40
43
46
51
38
42
45
49
54
45
49
53
57
63
48
52
56
61
67
39
43
46
50
55
1'
200
- 63
3 27
30
32
34
38
33
36
39
42
47
39
43
46
50
55
41
45
49
52
58
48
53
57
61
68
51
56
61
66
73
42
46
50
53
59
1'
300
- 68
3 29
32
34
37
40
35
39
42
45
50
42
46
49
53
59
44
48
52
56
62
52
56
61
66
73
55
60
65
70
78
45
49
53
57
63
1'
400
700
733
31
33
36
39
43
38
41
44
48
53
45
49
53
57
63
47
51
56
60
66
55
60
65
71
78
59
64
70
75
84
48
52
57
61
68
1'
500
78
3 32
35
38
41
45
40
44
47
51
56
47
52
56
60
67
50
55
59
64
71
59
64
70
75
83
63
69
74
80
89
51
56
60
65
72
1'
600
800
833
34
37
40
43
48
42
46
50
54
59
50
55
59
64
70
53
58
63
67
75
62
68
74
80
88
67
73
79
85
94
54
59
64
69
76
1'
700
88
3 36
39
42
45
50
44
48
52
56
62
53
58
62
67
74
56
61
66
71
79
66
72
78
84
93
70
77
83
90
10
0 57
62
67
73
80
1'
800
900
933
38
41
44
48
52
47
51
55
59
65
56
61
66
71
78
59
64
70
75
83
69
76
82
89
98
74
81
88
95
105
60
66
71
77
85
1'
900
98
3 39
43
46
50
55
49
53
58
62
69
58
64
69
74
82
62
67
73
79
87
73
80
86
93
10
3 78
85
93
10
0 11
1 63
69
75
80
89
2'
000
1'00
0 1'
033
41
45
48
52
57
51
56
60
65
72
61
67
72
78
86
65
71
77
82
91
77
84
91
98
108
82
90
97
105
116
66
72
78
84
93
2'
100
1'
083
43
47
50
54
60
54
58
63
68
75
64
70
76
81
90
68
74
80
86
95
80
87
95
102
113
86
94
102
110
- 69
75
82
88
98
2'
200
1'10
0 1'
133
45
49
52
56
62
56
61
66
71
78
67
73
79
85
94
71
77
84
90
100
84
91
99
107
118
90
98
106
114
- 72
79
85
92
10
2
2'
300
1'
183
46
50
55
58
65
58
63
68
73
81
69
76
82
88
98
74
80
87
94
104
87
95
103
111
- 93
10
2 11
1 11
9 -
75
82
89
96
106
2'
400
1'20
0 1'
233
48
52
57
61
67
60
66
71
76
84
72
79
85
92
102
77
83
90
97
108
91
99
107
116
- 97
10
6 11
5 -
- 78
85
92
10
0 11
0
2'
500
1'
283
50
54
58
63
69
63
68
74
79
87
75
82
89
95
105
80
87
94
101
112
94
103
112
120
- 10
1 11
0 12
0 -
- 81
89
96
10
3 11
5
2'
600
1'30
0 1'
333
52
56
61
65
72
65
71
76
82
91
78
85
92
99
109
82
90
97
105
116
98
107
116
- -
105
115
- -
- 84
92
10
0 10
7 11
9
2'
700
1'
383
53
58
63
67
74
67
73
79
85
94
81
88
95
102
113
85
93
101
109
120
101
111
120
- -
109
119
- -
- 87
95
10
3 11
1 -
2'
800
1'40
0 1'
433
55
60
65
69
77
69
75
82
88
97
83
91
98
106
117
88
96
104
112
- 10
5 11
5 -
- -
113
- -
- -
90
98
107
115
-
2'
900
1'
483
57
62
67
72
79
72
78
84
91
100
86
94
102
109
- 91
10
0 10
8 11
6 -
109
119
- -
- 11
6 -
- -
- 93
10
2 11
0 11
9 -
3'
000
1'50
0 1'
533
59
64
69
74
81
74
80
87
93
103
89
97
105
113
- 94
10
3 11
1 12
0 -
112
- -
- -
120
- -
- -
96
105
114
- -
-
1'60
0 1'
633
62
67
73
78
86
78
85
92
99
110
94
103
111
120
- 10
0 10
9 11
8 -
- 11
9 -
- -
- -
- -
- -
102
112
- -
-
-
1'70
0 1'
733
66
71
77
83
91
83
90
97
105
116
100
109
118
- -
106
116
- -
- -
- -
- -
- -
- -
- 10
8 11
8 -
- -
-
1'80
0 1'
833
69
75
81
87
96
87
95
103
111
- 10
5 11
5 -
- -
112
- -
- -
- -
- -
- -
- -
- -
114
- -
- -
-
1'90
0 1'
933
72
79
85
91
101
92
100
108
116
- 11
1 -
- -
- 11
8 -
- -
- -
- -
- -
- -
- -
- -
- -
- -
-
2'00
0 2'
033
76
83
89
96
106
96
105
113
- -
116
- -
- -
- -
- -
- -
- -
- -
- -
- -
- -
- -
- -
0639-990/02oPage 32 of 41
Description
2.8 Wingweightsinkg2.8.1 SLAwithprofilesystemPSX,PSXP
Ex
ecutionversions
Glasstypes/W
ingweigh
ts
ESG6mm
(15
kg/m
2 )ES
G8mm
(20
kg/m
2 )ES
G10mm(2
5 kg
/m2 )
VSG12mm(26,8kg/m
2 )VS
G14mm(32,7kg/m
2 )VS
G16mm(35,4kg/m
2 )IV24mm(27,5kg/m
2 )
Clearancewidth
Wing-
Wei
ght p
er w
ing
Wei
ght p
er w
ing
Wei
ght p
er w
ing
Wei
ght p
er w
ing
Wei
ght p
er w
ing
Wei
ght p
er w
ing
Wei
ght p
er w
ing
LB
width
at
cle
aran
ce h
eigh
t LH
at
cle
aran
ce h
eigh
t LH
at
cle
aran
ce h
eigh
t LH
at
cle
aran
ce h
eigh
t LH
at
cle
aran
ce h
eigh
t LH
at
cle
aran
ce h
eigh
t LH
at
cle
aran
ce h
eigh
t LH
2
win
gs
1 w
ing
2'10
0 2'
300
2'50
0 2'
700
3'00
0 2'
100
2'30
0 2'
500
2'70
0 3'
000
2'10
0 2'
300
2'50
0 2'
700
3'00
0 2'
100
2'30
0 2'
500
2'70
0 3'
000
2'10
0 2'
300
2'50
0 2'
700
3'00
0 2'
100
2'30
0 2'
500
2'70
0 3'
000
2'10
0 2'
300
2'50
0 2'
700
3'00
0
Thewingsizeislimitedbythemaximum
wingweightof120kganbythemaximum
dimensionsoftheglasspanelspecifiedbytheglassmanufacturer.
ES
G
Tem
pere
d sa
fety
gla
ss
VS
G
Lam
inat
ed g
lass
IV
In
sula
ted
glas
s
0639-990-01---10o_2013.09.indd
SLA
1'
000
- 52
8 19
20
22
24
26
28
29
32
34
30
33
36
1'
100
- 57
8 20
22
24
26
28
31
32
34
37
33
36
39
1'
200
- 62
8 22
24
26
28
31
33
34
37
41
36
39
42
1'
300
- 67
8 24
26
28
30
33
36
37
40
44
38
42
46
1'
400
700
728
25
28
30
32
35
38
40
43
47
41
45
49
1'
500
77
8 27
29
32
35
38
41
42
46
50
44
48
52
1'
600
800
828
29
31
34
37
40
44
45
49
53
47
51
56
1'
700
87
8 30
33
36
39
43
46
48
52
57
50
54
59
1'
800
900
928
32
35
38
41
45
49
50
55
60
52
57
62
1'
900
97
8 33
37
40
43
47
51
53
58
63
55
60
66
2'
000
1'00
0 1'
028
35
38
42
45
50
54
56
61
66
58
63
69
2'
100
1'
078
37
40
44
48
52
57
58
64
69
61
67
72
2'
200
1'10
0 1'
128
38
42
46
50
54
59
61
67
73
64
70
76
2'
300
1'
178
40
44
48
52
57
62
64
70
76
66
73
79
2'
400
1'20
0 1'
228
42
46
49
54
59
64
66
73
79
69
76
82
2'
500
1'
278
43
47
51
56
62
67
69
76
82
72
79
86
-
1'30
0 1'
328
45
49
53
58
64
69
72
79
85
75
82
89
0639-990/02oPage 33 of 41
Description
2.8.2 SLAwithprofilesystemPSA
Ex
ecutionversions
Glasstypes/W
ingweigh
ts
ES
G6mm(15,3kg/m
2 )ES
G8mm(20,4kg/m
2 )ES
G10mm(25,5kg/m
2 )VS
G10mm(26,6kg/m
2 )
Clearancewidth
Wing-
Wei
ght p
er w
ing
Wei
ght p
er w
ing
Wei
ght p
er w
ing
Wei
ght p
er w
ing
LB
width
at
cle
aran
ce h
eigh
t LH
at
cle
aran
ce h
eigh
t LH
at
cle
aran
ce h
eigh
t LH
at
cle
aran
ce h
eigh
t LH
2 w
ings
1
win
g
2'10
0 2'
300
2'50
0 2'
100
2'30
0 2'
500
2'10
0 2'
300
2'50
0 2'
100
2'30
0 2'
500
Thewingsizeislimitedbythemaximum
wingweightof100kganbythemaximum
dimensionsoftheglasspanelspecifiedbytheglassmanufacturer.
ES
G
Tem
pere
d sa
fety
gla
ss
VS
G
Lam
inat
ed g
lass
0639-990-01---10o_2013.09.indd
SLA
90
0 -
488
26
29
31
34
37
31
34
37
40
45
27
30
32
35
39
33
36
39
42
46
1'
000
- 53
8 29
32
34
37
41
35
38
41
44
49
30
33
36
39
43
36
39
43
46
51
1'
100
- 58
8 31
34
37
40
45
38
41
45
49
54
33
36
39
42
47
39
43
47
50
56
1'
200
- 63
8 34
37
41
44
49
41
45
49
53
59
36
39
42
46
51
43
47
51
55
61
1'
300
- 68
8 37
40
44
47
53
44
48
53
57
63
38
42
46
49
55
46
50
55
59
65
1'
400
700
738
40
43
47
51
56
47
52
56
61
68
41
45
49
53
59
49
54
59
63
70
1'
500
78
8 42
46
50
54
60
51
55
60
65
72
44
48
52
57
63
52
57
62
67
75
1'
600
800
838
45
49
53
58
64
54
59
64
69
77
47
51
56
60
67
56
61
66
72
80
1'
700
88
8 48
52
57
61
68
57
62
68
73
82
50
54
59
64
71
59
65
70
76
85
1'
800
900
938
50
55
60
65
72
60
66
72
77
86
52
57
62
67
75
62
68
74
80
89
1'
900
98
8 53
58
63
68
76
63
70
76
82
91
55
61
66
71
79
66
72
78
85
94
2'
000
1'00
0 1'
038
56
61
66
71
79
67
73
79
86
95
58
64
69
75
83
69
76
82
89
99
2'
100
1'
088
58
64
69
75
83
70
77
83
90
100
61
67
72
78
87
72
79
86
93
104
2'
200
1'10
0 1'
138
61
67
73
78
87
73
80
87
94
104
64
70
76
82
91
76
83
90
97
108
2'
300
1'
188
64
70
76
82
91
76
84
91
98
109
66
73
79
85
95
79
87
94
102
113
2'
400
1'20
0 1'
238
66
73
79
85
95
80
87
95
102
114
69
76
82
89
99
82
90
98
106
118
2'
500
1'
288
69
76
82
89
99
83
91
99
106
118
72
79
86
93
103
86
94
102
110
-
-
1'30
0 1'
338
72
78
85
92
102
86
94
102
111
- 75
82
89
96
10
7 89
98
10
6 11
5 -
-
1'40
0 1'
438
77
84
92
99
110
92
101
110
119
- 80
88
96
10
3 11
5 96
10
5 11
4 -
-
-
1'50
0 1'
538
82
90
98
106
118
99
108
118
- -
86
94
102
111
120
102
112
120
- -
0639-990/02oPage 34 of 41
Description
2.8.3 SLAwithprofilesystemPSF
Ex
ecutionversions
Glasstypes/W
ingweigh
ts
ESG10mm(25,5kg/m
2 ) ES
G 1
2 m
m(30,6kg/m
2 )VS
G/TVG
10mm(26,6kg/m
2 )VS
G/TVG
12mm(31,7kg/m
2 )
Clearancewidth
Glass
Wei
ght p
er w
ing
Wei
ght p
er w
ing
Wei
ght p
er w
ing
Wei
ght p
er w
ing
LB
width
at
cle
aran
ce h
eigh
t LH
at
cle
aran
ce h
eigh
t LH
at
cle
aran
ce h
eigh
t LH
at
cle
aran
ce h
eigh
t LH
2
win
gs
1 w
ing
2'10
0 2'
300
2'50
0 2'
700
3'00
0 2'
100
2'30
0 2'
500
2'70
0 3'
000
2'10
0 2'
300
2'50
0 2'
700
3'00
0 2'
100
2'30
0 2'
500
2'70
0 3'
000
Thewingsizeislimitedbythemaximum
wingweightof150kganbythemaximum
dimensionsoftheglasspanelspecifiedbytheglassmanufacturer.
ES
G
Tem
pere
d sa
fety
gla
ss
VS
G
Lam
inat
ed g
lass
TV
G
sem
i-tem
pere
d
0639-990-01---10o_2013.09.indd
SLA
90
0 -
535
36
39
43
46
50
41
44
48
51
57
1'
000
- 58
5 39
42
46
49
54
44
48
52
56
61
1'
100
- 63
5 42
46
49
53
58
48
52
56
60
66
1'
200
- 68
5 45
49
53
56
62
51
55
60
64
71
1'
300
- 73
5 48
52
56
60
66
54
59
64
69
76
1'
400
700
785
51
55
59
64
70
58
63
68
73
80
1'
500
- 83
5 54
58
63
67
74
61
66
72
77
85
1'
600
800
885
56
61
66
71
78
64
70
76
81
90
1'
700
- 93
5 59
64
69
74
82
68
74
80
86
95
1'
800
900
985
62
67
73
78
86
71
77
84
90
99
1'
900
- 1'
035
65
70
76
82
90
74
81
88
94
104
2'
000
1'00
0 1'
085
68
74
79
85
94
78
85
92
98
109
2'
100
- 1'
135
71
77
83
89
98
81
88
96
103
113
2'
200
1'10
0 1'
185
74
80
86
93
102
85
92
100
107
118
2'
300
- 1'
235
76
83
89
96
106
88
96
104
111
-
2'
400
1'20
0 1'
285
79
86
93
100
110
91
99
107
116
-
2'
500
- 1'
335
82
89
96
103
114
95
103
111
120
-
2'
600
1'30
0 1'
385
85
92
99
107
118
98
107
115
- -
2'
700
- 1'
435
88
95
103
111
- 10
1 11
0 11
9 -
-
2'
800
1'40
0 1'
485
90
98
106
114
- 10
5 11
4 -
- -
2'
900
- 1'
535
93
101
110
118
- 10
8 11
8 -
- -
3'
000
1'50
0 1'
585
96
105
113
- -
111
- -
- -
-
1'60
0 1'
685
101
111
120
- -
118
- -
- -
-
1'70
0 1'
785
107
117
- -
- -
- -
- -
-
1'80
0 1'
885
113
- -
- -
- -
- -
-
-
1'90
0 1'
985
119
- -
- -
- -
- -
-
-
2'00
0 2'
085
- -
- -
- -
- -
- -
0639-990/02oPage 35 of 41
Description
2.8.4 SLAwithprofilesystemPSW
Ex
ecutionversions
Glasstypes/W
ingweigh
ts
IV24mm(5/14/5)25,5kg/m
2 IV24mm(6/12/6)30,6kg/m
2
Clearancewidth
Wing-
Wei
ght p
er w
ing
Wei
ght p
er w
ing
LB
width
at
cle
aran
ce h
eigh
t LH
at
cle
aran
ce h
eigh
t LH
2 w
ings
1
win
g
2'10
0 2'
300
2'50
0 2'
700
3'00
0 2'
100
2'30
0 2'
500
2'70
0 3'
000
Thewingsizeislimitedbythemaximum
wingweightof120kganbythemaximum
dimensionsoftheglasspanelspecifiedbytheglass
man
ufac
ture
r.
IV
Insu
late
d gl
ass
0639-990-01---10o_2013.09.indd
SLA
56
56
M3
65±2
90
60
90
EU
82
67 63
6982-501
CH 78
77
56
717,5
86
Ø16
30
15
Ø4,25
Ø91431
27,5
0635-142 0723-170 0630-431
13 1086
0635-143
Feller-KIT
28,3 986
0639-990/02oPage 36 of 41
Description
2.9 Controlandsafetyelements
Flush-typebox
Dim
ensi
ons
Cutout in the wall frame
Wall cutout
AUTOM. NIGHT OPEN MAN. EXIT
by customer
D-BEDIXProgram selector keyFlush-type/panel/wallframeProtection type IP 40
Surface-type frameProtection type IP 40
Attention:We advise to use control elements (radars,push-buttons,codelock,etc.)fromtheGilgenproductrange.Gilgen cannot assume any functio-nal guarantee if elements from other suppliersarebeingused!
by customer
byD-BEDIX
Key-operated program switchFlush-type/panel/wallframeProtection type IP 40
NIGHT AUTOM. MANUAL EXIT
0639-990-01---10o_2013.09.indd
SLA
CH EU
0635-148/04 0635-148/02
87
148
43 15
7,3
6982-502
77,5 57
140
65 63
148,5
BKS 8900 N BL 31BKS 3101 N BL 31BKS 3301 N BL 31
ZEISS IKON 0040ZEISS IKON 5040ZEISS IKON 5044ZEISS IKON 6044ZEISS IKON 7044
74
54
140
0635-148/04
0635-148/02
88
158
43 15
7,3
CH EUCH
0635-144/02
0635-144/04
0635-148/02
+Se
t0635-219
6442-970
0635-148/02
+6442-970
0635-143
Feller-KIT
56
117
60
M3
Ø62
6442-971
6442-972Set0635-219
Ø62
M3
130,5
62
70
0639-990/02oPage 37 of 41
Description
KOMBI-D
-BEDIX
Pro
gram
sel
ecto
r key
.C
ylin
der s
uppl
ied
by
cust
omer
Function
MANUAL NIGHT AUTOMATIC EXIT OPEN
Application Surface-type frameProtection type IP 40
Dimensi-ons
Flush-type/panel/wallframeProtection type IP 40
Lock
out o
fKOMBI-D
-BEDIX
Cylinder type
supplied by custo-mer
KABA 1514SEA 1.043.0DOM 2222H ix5Driverwith8adjus.possibilities
KESO 11.014.045KESO 21.014.045KESO 31.014.045AdjustablebeardE201
KESO 21.214.040AdjustablebeardE200
DOM 333 ix-5Driverwith8adjustingpossibilities
Cutout in the wall frame
Flush-typebox
by c
usto
mer
Switch kit
Covering frame
by customer
byD-BEDIX
0639-990-01---10o_2013.09.indd
SLA
P20.04.37
Radar DOMINO
P20.04.32
Radar MERKUR
P20.04.53
Radar Activ 8 ONE ON
P20.04.60
P20.06.01
T20.40.21 T20.37.11
6452-170
0639-990/02oPage 38 of 41
Description
Key-operated pivoting switchPush-button
Ifrared light detector ATC
Light barrier GLS-05 Set button light barrier
0639-990-01---10o_2013.09.indd
SLA
!
0639-990/02oPage 39 of 41
Description
3 SAFETYThe required safety elements must be installed in accordance with the EU directives as well as with the safety regulations valid in the country of application.
Attention:We advise to use safety elements from the Gilgen product range. Gilgen cannot assume any functional guarantee if elements from other suppliers are beingused!
3.1 Safetydevices3.1.1 Reversingandstoppingmechanism
Ifthedoorwingsmeetanobstacleduringtheclosingprocess,thedriveunitimmediatelystopsandreopensthewings.Forreasonsofpersonalsafety,thenextclosingattemptis performed after 3 seconds with reduced speed from the point where the obstacle had been detected.
Ifthedoortouchesanobstacleduringtheopeningprocedure,itisimmediatelystopped.Forreasonsofpersonalsafety,thenextopeningattemptisperformedwithreducedspeed from the point where the obstacle had been detected.
3.1.2 Limitationoftheforce
The static driving powerislimitedto150N(accordingtoDIN18650).
Warning:In cases where the main closing edge/the secondary closing edge are not monitored/protectedbyapresencedetector/aprotectionwing,thisprotectionmust be ensured by means of a reduction of the dynamic forces of the door wing(seeOperatinginstructions0639-990/22).
3.1.3 Residualcurrentcircuitbreaker
We advise to protect the mains supply line by installing a residual current circuit breaker.
0639-990-01---10o_2013.09.indd
SLA
0639-990/02oPage 40 of 41
Description
3.2 Safetyregulations3.2.1 Principles
The installation may only be installed and operated in dry rooms. If this condition cannot befulfilled,thecustomermustprovidesufficientprotectionfrommoisture.
The installation must not be mounted within locations presenting explosion hazards. The presenceofflammablegasesorsmokerepresentsaconsiderablesafetyhazard.
3.2.2 Service
Inordertoguaranteethesafetyoftheusersatalltimes,theinstallationmustbecheckedwithregardtoitssafeconditionbeforethefirstcommissioningandduringnormalopera-tion,atleastonceayear, by a competent specialist. The correct maintenance/checking mustbeconfirmedbyenteringthedateandsignatureintothecontrolbooklet.
0639-990-01---10o_2013.09.indd
SLA
25*
30
15 15
15 15
LB
X X
25*
LB+2X+80
FB FB
Amin.=LB+2FB+50
S
FBFB
XX
0639-990/02oPage 41 of 41
Description
Door closed
Door open
Monitoring of the main/secondary closing edge according to DIN 18650 (see Risk evalua-tionforanautomaticslidingdoorP01.02.01resp.P01.02.40).
3.2.3 Slidingwingsandfixedsidepanels
Theslidingwingsaswellasthesidepanels(includingtheirfillings)mustbemanufac-turedofamaterialthatexcludesallriskofinjuryfortheusers.Itshallbefreeofsharpedges and in the event of a glass breakage must not produce any cutting splinters. In caseswheretheglazedslidingwingsarenotfittedwithaperipheralframe,nocontact„glass on glass“ shall take place while the door is being operated.
The sliding wings must be solidly built and must be protected against derailing from the guideprofiles.
Transparentsslidingwingsandfixedsidepanels(ortheirsurfaces)mustbeclearlyreco-gnizable,e.g.bymeansofapermanentmarkingordyedmaterials.
Warning:Incaseswherethedistance(S)betweenthemainsurfaceoftheslidingwingandofthesealingprofilemeasuresbetween8and25mm,aminimumsafetydistance*of25mm*mustabsolutelyberespected,whichmeansthatthe sliding wings must not be completely opened.