2
Small Size, Greater Diagnostic Insight Key Features Cannulate deep into the CS and its side branches to map ventricular arrhythmias Ideal for left-sided WPW cases to more precisely locate the site of the accessory pathway Provides mapping within the middle cardiac vein (MCV) for posteroseptal pathways Ideal for Vein of Marshall mapping for inferior left atrial pathways Catheter Specifications • 4/3.3F • Guidewire Tip: 15mm / 0.026” • Length: 120cm • Electrodes: 10 & 20 • Electrode spacing: 2-2-2 mm, 5-5-5mm, 2-5-2mm, 2-8-2mm & 2-10-2mm • Curve type: S (straight) Access Point Technologies EP, Inc. 12560 Fletcher Lane Suite 300, Rogers MN 55374 763-432-9004, www.accesspointus.com

Small Size, Greater Diagnostic Insight … · Small Size, Greater Diagnostic Insight Key Features •Cannulate deep into the CS and its side branches to map ventricular arrhythmias

  • Upload
    others

  • View
    11

  • Download
    1

Embed Size (px)

Citation preview

Page 1: Small Size, Greater Diagnostic Insight … · Small Size, Greater Diagnostic Insight Key Features •Cannulate deep into the CS and its side branches to map ventricular arrhythmias

Small Size, Greater Diagnostic Insight

Key Features •Cannulate deep into the CS and itsside branches to map ventriculararrhythmias

•Ideal for left-sided WPW cases tomore precisely locate the site of theaccessory pathway

•Provides mapping within the middle

cardiac vein (MCV) for posteroseptal

pathways

•Ideal for Vein of Marshall mappingfor inferior left atrial pathways

Catheter Specifications • 4/3.3F

• Guidewire Tip: 15mm / 0.026”

• Length: 120cm

• Electrodes: 10 & 20

• Electrode spacing:2-2-2 mm, 5-5-5mm, 2-5-2mm,

2-8-2mm & 2-10-2mm

• Curve type: S (straight)

Access Point Technologies EP, Inc. 12560 Fletcher Lane Suite 300, Rogers MN 55374

763-432-9004, www.accesspointus.com

Page 2: Small Size, Greater Diagnostic Insight … · Small Size, Greater Diagnostic Insight Key Features •Cannulate deep into the CS and its side branches to map ventricular arrhythmias

APT EP Map-iT™ 4/3.3F Decapolar Fixed Curve Electrophysiology Catheter

Ref No. 903226

Usable length (cm)

120

Electrode Spacing (mm)

2-2-2

Ring Electrode (mm) Tip 1 .026” guidewire

Curve S

903219 120 2-5-2 1 .026” guidewire S 903215 120 2-8-2 1 .026” guidewire S 903217 120 5-5-5 1 .026” guidewire S

Connection cable: Ref No. 901957

APT EP Map-iT™ 4/3.3F Duo-Decapolar Fixed Curve Electrophysiology Catheter Ref No.

903269 Usable length (cm)

120 Electrode Spacing (mm)

2-2-2

Ring Electrode (mm) Tip 1 .026” guidewire

Curve

S

903273 120 2-5-2 1 .026” guidewire S 903256 1 S

903271

903257

120

120

5-5-5

2-10-2 1

.026” guidewire

.026” guidewire

S

S

Connection cable: Ref No. 901957 2 cables required

12560 Fletcher Lane, Suite 300, Rogers MN 55374

763-432-9004, www.accesspointus.comAccess Point Technologies EP, Inc.

200654-000 Rev. B

903221 120 2-10-2 1 .026” guidewire S

120 2-8-21

.026" guidewire