198
SOLENOID OPERATED DIRECTIONAL CONTROLS Page SD1 W 20 / 2018 Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512 mail: [email protected]www.tecnord.com 4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 mail: [email protected]www.delta-power.com WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken without independent study, evaluation, and testing for suitability. 2W2P NORMALLY CLOSED POPPET VALVES ............................................................................................................................ SD2 2W2P NORMALLY CLOSED BIDIRECTIONAL VALVES ......................................................................................................... SD41 2W2P NORMALLY CLOSED SPOOL VALVES............................................................................................................................... SD51 2W2P NORMALLY OPEN POPPET VALVES ................................................................................................................................. SD60 2W2P NORMALLY OPEN SPOOL VALVES ................................................................................................................................... SD89 3W2P SPOOL VALVES ............................................................................................................................................................................ SD98 4W2P SPOOL VALVES ............................................................................................................................................................................ SD122 4W3P SPOOL VALVES .......................................................................................................................................................................... SD164 TRANSMISSION & BRAKE SPOOL VALVES ................................................................................................................................ SD197 SOLENOID OPERATED DIRECTIONAL CONTROLS

SOLENOID OPERATED DIRECTIONAL … 1000 38 69 7/8-14 DE-S2F SD18 2 WAY 2 POSITION NORMALLY CLOSED POPPET VALVES SLID PRATD DIRTIAL TRLS Page SD3 Via Malavolti, 36 • 41122 Modena •

Embed Size (px)

Citation preview

Page 1: SOLENOID OPERATED DIRECTIONAL … 1000 38 69 7/8-14 DE-S2F SD18 2 WAY 2 POSITION NORMALLY CLOSED POPPET VALVES SLID PRATD DIRTIAL TRLS Page SD3 Via Malavolti, 36 • 41122 Modena •

SOLENOID OPERATED DIRECTIONAL CONTROLS

Page SD1

W 2

0 /

2018

Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512 mail: [email protected] • www.tecnord.com

4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 mail: [email protected] • www.delta-power.com

WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken without independent study, evaluation, and testing for suitability.

2W2P NORMALLY CLOSED POPPET VALVES ............................................................................................................................ SD2

2W2P NORMALLY CLOSED BIDIRECTIONAL VALVES ......................................................................................................... SD41

2W2P NORMALLY CLOSED SPOOL VALVES ............................................................................................................................... SD51

2W2P NORMALLY OPEN POPPET VALVES ................................................................................................................................. SD60

2W2P NORMALLY OPEN SPOOL VALVES ................................................................................................................................... SD89

3W2P SPOOL VALVES ............................................................................................................................................................................ SD98

4W2P SPOOL VALVES ............................................................................................................................................................................ SD122

4W3P SPOOL VALVES .......................................................................................................................................................................... SD164

TRANSMISSION & BRAKE SPOOL VALVES ................................................................................................................................ SD197

SOLENOID OPERATED DIRECTIONAL CONTROLS

Page 2: SOLENOID OPERATED DIRECTIONAL … 1000 38 69 7/8-14 DE-S2F SD18 2 WAY 2 POSITION NORMALLY CLOSED POPPET VALVES SLID PRATD DIRTIAL TRLS Page SD3 Via Malavolti, 36 • 41122 Modena •

SOLENOID OPERATED DIRECTIONAL CONTROLS

Page SD2

W 20 / 2018

Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512 mail: [email protected] • www.tecnord.com

4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 mail: [email protected] • www.delta-power.com

WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken without independent study, evaluation, and testing for suitability.

2W2P NORMALLY CLOSED GPM PSI LPM BAR CAVITY MODEL PAGE

6 4000 23 276 5/8-18 UA-S2A SD4

8 3500 30 241 3/4-16 PB-S2A SD8

12 5000 45 345 3/4-16 HB-S2A SD10

15 3500 57 241 7/8-14 DE-S2A SD14

15 4000 57 276 7/8-14 HE-S2A SD16

25 3000 95 207 1 1/16-12 TT-S2A SD20

30 3500 114 241 1 5/16-12 SJ-S2A SD22

40 4350 151 300 1 5/16-12 HJ-S2A SD24

8 3500 30 241 3/4-16 PB-S2B SD26

12 5000 45 345 3/4-16 HB-S2B SD28

15 3500 57 241 7/8-14 DE-S2B SD30

15 4000 57 276 7/8-14 HE-S2B SD32

25 3000 95 207 1 1/16-12 TT-S2B SD34

25 5000 95 345 1 1/16-12 HT-S2B SD36

30 3500 114 241 1 5/16-12 SJ-S2B SD38

SOFT SEAT

4 3000 15 207 5/8-18 UA-S2F SD6

6 2500 23 172 3/4-16 PB-S2F SD12

10 1000 38 69 7/8-14 DE-S2F SD18

2 WAY 2 POSITION NORMALLY CLOSED POPPET VALVES

Page 3: SOLENOID OPERATED DIRECTIONAL … 1000 38 69 7/8-14 DE-S2F SD18 2 WAY 2 POSITION NORMALLY CLOSED POPPET VALVES SLID PRATD DIRTIAL TRLS Page SD3 Via Malavolti, 36 • 41122 Modena •

SOLENOID OPERATED DIRECTIONAL CONTROLS

Page SD3

W 2

0 /

2018

Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512 mail: [email protected] • www.tecnord.com

4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 mail: [email protected] • www.delta-power.com

WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken without independent study, evaluation, and testing for suitability.

TYPICAL SCHEMATIC

Typical application for the S2A is load holding and lowering in a lift, check and dump circuit. Typical application for the S2B is load holding and lowering when free flow in both directions is required to float the cylinder. Typical application for the S2F is load holding and lowering of a cylinder in low pressure application where the soft seat gives better leakage control.

Page 4: SOLENOID OPERATED DIRECTIONAL … 1000 38 69 7/8-14 DE-S2F SD18 2 WAY 2 POSITION NORMALLY CLOSED POPPET VALVES SLID PRATD DIRTIAL TRLS Page SD3 Via Malavolti, 36 • 41122 Modena •

SOLENOID OPERATED DIRECTIONAL CONTROLS

Page SD4

Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512 mail: [email protected] • www.tecnord.com

4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 mail: [email protected] • www.delta-power.com

WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken without independent study, evaluation, and testing for suitability.

W 20 / 2018

UA-S2A PILOT OPERATED POPPET, 2 WAY, NORMALLY CLOSED

DESCRIPTION7 size, 5/8-18 thread, “Mini” series, solenoid operated, 2 way normally closed, pilot operated poppet valve with reverse flow de-energized.

OPERATIONWhen de-energized the UA-S2A blocks flow from (1) to (2) and allows reverse flow from (2) to (1). When energized, the valve allows flow from (1) to (2) and restricts flow from (2) to (1).

FEATURES • Hardened parts for long life.• Efficient wet-armature construction.• Cartridges are voltage interchangeable.• Industry common cavity.• Unitized, molded coil design.• Continuous duty rated solenoid.• Optional coil voltages and terminations.

Nominal Flow 6 GPM (23 LPM)Rated Operating Pressure 4000 PSI (276 bar)Typical Internal Leakage (150 SSU) 0-5 drops/minViscosity Range 36 to 3000 SSU (3 to 647 cSt)Filtration ISO 18/16/13Media Operating Temp. Range -40° to 250°F (-40° to 120°C)Weight .13 lbs (.06 kg)Operating Fluid Media General Purpose Hydraulic FluidCartridge Torque Requirements 15 ft-lbs (20.3 Nm)Coil Nut Torque Requirements 4-6 ft-lbs (5.4-8.1 Nm)Cavity MINI 2WCavity Form Tool (Finishing) 40500003Seal Kit 21191000

Actual Test Data (Cartridge Only)

VALVE SPECIFICATIONS

0

50

100

150

200

250

300

0 2 4 6 8Flow (G PM)

0

5

10

15

20

0 5

Pre

ssur

e D

rop

(PS

I)

10 15 20 25 30Flow (LPM )

Pre

ssur

e D

rop

(BA

R)

Port 1 to 2 (eng) Port 2 to 1 (de-eng)

0

50

100

150

200

250

300

0 2 4 6 8Flow (G PM)

0

5

10

15

20

0 5

Pre

ssur

e D

rop

(PS

I)

10 15 20 25 30Flow (LPM )

Pre

ssur

e D

rop

(BA

R)

Port 1 to 2 (eng) Port 2 to 1 (de-eng)

PERFORMANCE

HYDRAULIC SYMBOL Uses “P” or “PI” type coils

2

1

Page 5: SOLENOID OPERATED DIRECTIONAL … 1000 38 69 7/8-14 DE-S2F SD18 2 WAY 2 POSITION NORMALLY CLOSED POPPET VALVES SLID PRATD DIRTIAL TRLS Page SD3 Via Malavolti, 36 • 41122 Modena •

SOLENOID OPERATED DIRECTIONAL CONTROLS

Page SD5

Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512 mail: [email protected] • www.tecnord.com

4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 mail: [email protected] • www.delta-power.com

WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken without independent study, evaluation, and testing for suitability.

W 2

0 /

2018

DIMENSIONS

ORDERING INFORMATIONApproximate Coil Weight: .30 lbs (.14 kg)

OPTIONS BODIESBuna Standard 00 Blank Without BodyViton Standard V0 N 1/4 NPTF PortsBuna, Screen A0 S #6 SAE PortsViton, Screen W0

Note: use screen only if flow direction is from (1) to (2)

VOLTAGE06 6 VDC12 12 VDC24 24 VDC36 36 VDC48 48 VDC25 24 VAC11 120 VAC22 220 VAC

“P” COIL TERMINATION 44 440 VAC(All DC Except as Noted)

IMMERSION PROOF “P” TYPEDL Double Lead SS Single Spade IA “I” Coil AMP Superseal - IntegralDT Deutsch on Leads DT04-2P DS Double Spade ID “I” Coil Deutsch - Integral DT04-2PML Metri-Pack on Leads HC DIN 43650 (Hirschmann) - (AC&DC) IJ “I” Coil AMP Jr. Timer - IntegralPL Packard on Leads CL Conduit Lead - (AC Only) IM “I” Coil Metri-Pack - IntegralWL Weatherpack on Leads DI Deutsch - Integral DT04-2P

UA-S2A – – – –

Note: Aluminum, NOT durability rated for 4000 PSI. Consult factory for body options.

Page 6: SOLENOID OPERATED DIRECTIONAL … 1000 38 69 7/8-14 DE-S2F SD18 2 WAY 2 POSITION NORMALLY CLOSED POPPET VALVES SLID PRATD DIRTIAL TRLS Page SD3 Via Malavolti, 36 • 41122 Modena •

SOLENOID OPERATED DIRECTIONAL CONTROLS

Page SD6

Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512 mail: [email protected] • www.tecnord.com

4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 mail: [email protected] • www.delta-power.com

WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken without independent study, evaluation, and testing for suitability.

W 20 / 2018

UA-S2F PILOT OPERATED POPPET, 2 WAY NORMALLY CLOSED – SOFT SEAT

DESCRIPTION7 size, 5/8-18 thread, “Mini” series, solenoid operated, 2 way normally closed, pilot operated soft seat poppet valve with reverse flow de-energized.

OPERATIONWhen de-energized the UA-S2F blocks flow from (1) to (2) and allows free reverse flow from (2) to (1).When energized, the valve allows flow from (1) to (2) and restricts flow from (2) to (1).

FEATURES • Soft seat for ultra low leakage.• Efficient wet-armature construction.• Cartridges are voltage interchangeable.• Industry common cavity.• Unitized, molded coil design.• Continuous duty rated solenoid.• Optional coil voltages and terminations.

Nominal Flow 4 GPM (15 LPM)Rated Operating Pressure 3000 PSI (207 bar)Typical Internal Leakage (150 SSU) NegligibleViscosity Range 36 to 3000 SSU (3 to 647 cSt)Filtration ISO 18/16/13Media Operating Temp. Range 32° to 160°F (0° to 70°C)Weight .12 lbs (.05 kg)Operating Fluid Media General Purpose Hydraulic FluidCartridge Torque Requirements 15 ft-lbs (20.3 Nm)Coil Nut Torque Requirements 4-6 ft-lbs (5.4-8.1 Nm)Cavity MINI 2WCavity Form Tool (Finishing) 40500003Seal Kit 21191000

Actual Test Data (Cartridge Only)

VALVE SPECIFICATIONS

Uses “P” or “PI” type coils

PERFORMANCE

HYDRAULIC SYMBOL

0

50

100

150

200

250

0 2 4 6 8Flow (GPM)

0

5

10

15

0 5 10 15

Pres

sure

Dro

p (P

SI)

20 25 30

Flow (LPM)

Pres

sure

Dro

p (B

AR)

Port 1 to 2 (eng) Port 2 to 1 (de-eng)

0

50

100

150

200

250

0 2 4 6 8Flow (GPM)

0

5

10

15

0 5 10 15

Pres

sure

Dro

p (P

SI)

20 25 30

Flow (LPM)

Pres

sure

Dro

p (B

AR)

Port 1 to 2 (eng) Port 2 to 1 (de-eng)

2

1

Page 7: SOLENOID OPERATED DIRECTIONAL … 1000 38 69 7/8-14 DE-S2F SD18 2 WAY 2 POSITION NORMALLY CLOSED POPPET VALVES SLID PRATD DIRTIAL TRLS Page SD3 Via Malavolti, 36 • 41122 Modena •

SOLENOID OPERATED DIRECTIONAL CONTROLS

Page SD7

Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512 mail: [email protected] • www.tecnord.com

4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 mail: [email protected] • www.delta-power.com

WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken without independent study, evaluation, and testing for suitability.

W 2

0 /

2018

DIMENSIONS

ORDERING INFORMATIONApproximate Coil Weight: .30 lbs (.14 kg)

OPTIONS BODIESBuna Standard 00 Blank Without BodyViton Standard V0 N 1/4 NPTF PortsBuna, Screen A0 S #6 SAE PortsViton, Screen W0

Note: use screen only if flow direction is from (1) to (2)

VOLTAGE06 6 VDC12 12 VDC24 24 VDC36 36 VDC48 48 VDC25 24 VAC11 120 VAC22 220 VAC

“P” COIL TERMINATION 44 440 VAC(All DC Except as Noted)

IMMERSION PROOF “P” TYPEDL Double Lead SS Single Spade IA “I” Coil AMP Superseal - IntegralDT Deutsch on Leads DT04-2P DS Double Spade ID “I” Coil Deutsch - Integral DT04-2PML Metri-Pack on Leads HC DIN 43650 (Hirschmann) - (AC&DC) IJ “I” Coil AMP Jr. Timer - IntegralPL Packard on Leads CL Conduit Lead - (AC Only) IM “I” Coil Metri-Pack - IntegralWL Weatherpack on Leads DI Deutsch - Integral DT04-2P

UA-S2F – – – –

Page 8: SOLENOID OPERATED DIRECTIONAL … 1000 38 69 7/8-14 DE-S2F SD18 2 WAY 2 POSITION NORMALLY CLOSED POPPET VALVES SLID PRATD DIRTIAL TRLS Page SD3 Via Malavolti, 36 • 41122 Modena •

SOLENOID OPERATED DIRECTIONAL CONTROLS

Page SD8

Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512 mail: [email protected] • www.tecnord.com

4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 mail: [email protected] • www.delta-power.com

WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken without independent study, evaluation, and testing for suitability.

W 20 / 2018

PB-S2A PILOT OPERATED POPPET, 2 WAY NORMALLY CLOSED

DESCRIPTION8 size, 3/4-16 thread, “Power” series, solenoid operated, 2 way normally closed, pilot operated poppet valve with reverse flow de-energized.

OPERATIONWhen de-energized the PB-S2A blocks flow from (1) to (2) and allows reverse flow from (2) to (1). When energized the valve allows flow from (1) to (2) and restricts flow from (2) to (1).OPERATION OF MANUAL OVERRIDE OPTION: to override, pull knob out. On the detented version, after pulling knob out twist 180 degrees and release. The valve will remain in that position.

FEATURES • Hardened parts for long life.• Efficient wet-armature construction.• Cartridges are voltage interchangeable.• Manual override option.• Industry common cavity.• Unitized, molded coil design.• Continuous duty rated solenoid.• Optional coil voltages and terminations.• Optional “I” Coil: Weatherproof, Thermal Shock, Immersion Safe.

Nominal Flow 8 GPM (30 LPM)Rated Operating Pressure 3500 PSI (241 bar)Typical Internal Leakage (150 SSU) 0-5 drops/minViscosity Range 36 to 3000 SSU (3 to 647 cSt)Filtration ISO 18/16/13Media Operating Temp. Range -40° to 250°F (-40° to 120°C)Weight .20 lbs (.09 kg)Operating Fluid Media General Purpose Hydraulic FluidCartridge Torque Requirements 25 ft-lbs (34 Nm)Coil Nut Torque Requirements 4-6 ft-lbs (5.4-8.1 Nm)Cavity POWER 2WCavity Tools Kit (form tool, reamer, tap) 40500005Seal Kit 21191100

Actual Test Data (Cartridge Only)

VALVE SPECIFICATIONS

0

50

100

150

200

250

0 2 4 6 8 10Flow (GPM)

0

5

10

15

0 10 20 30Flow (LPM)

Pre

ssur

e D

rop

(bar

)

Port 1 to 2 (eng) Port 2 to 1 (de-eng)

Pre

ssur

e D

rop

(PS

I)

PERFORMANCE

HYDRAULIC SYMBOL

2

1

Page 9: SOLENOID OPERATED DIRECTIONAL … 1000 38 69 7/8-14 DE-S2F SD18 2 WAY 2 POSITION NORMALLY CLOSED POPPET VALVES SLID PRATD DIRTIAL TRLS Page SD3 Via Malavolti, 36 • 41122 Modena •

SOLENOID OPERATED DIRECTIONAL CONTROLS

Page SD9

Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512 mail: [email protected] • www.tecnord.com

4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 mail: [email protected] • www.delta-power.com

WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken without independent study, evaluation, and testing for suitability.

W 2

0 /

2018

OPTIONS BODIESBuna Standard 00 Blank Without BodyViton Standard V0 N 1/4 NPTF Ports

Buna, Override, Detent 0M S #6 SAE PortsViton, Override, Detent VM

Buna, Screen A0Viton, Screen W0

Buna, Override, Non-Detent B1Viton, Override, Non-Detent V1 VOLTAGE

Buna, Screen, Override, Non-Detent B3 06 6 VDCViton, Screen, Override, Non-Detent V3 12 12 VDC

Buna, Screen, Override, Detent B4 24 24 VDCViton, Screen, Override, Detent V4 36 36 VDC

48 48 VDCNote: use screen only if flow 25 24 VAC

direction is from (1) to (2) 11 120 VAC22 220 VAC

“P” COIL TERMINATION 44 440 VAC(All DC Except as Noted)

IMMERSION PROOF “P” TYPEDL Double Lead SS Single Spade IA “I” Coil AMP Superseal - IntegralDT Deutsch on Leads DT04-2P DS Double Spade ID “I” Coil Deutsch - Integral DT04-2PML Metri-Pack on Leads HC DIN 43650 (Hirschmann) - (AC&DC) IJ “I” Coil AMP Jr. Timer - IntegralPL Packard on Leads CL Conduit Lead - (AC Only) IM “I” Coil Metri-Pack - IntegralWL Weatherpack on Leads DI Deutsch - Integral DT04-2P

PB-S2A – – – –

DIMENSIONS

ORDERING INFORMATIONApproximate Coil Weight: .42 lbs (.19 kg)

SEE COIL DATAFOR TERMINATIONS

.87 [22.1] HEX

3/4-16 UNF-2ATHREAD

2.90 [73.6]

1.09 [27.6]

2.13 [54.2]

1.25 [31.7]

1.54 [39.1]

.75 [19.1]

HEX NUT

STANDARD

MANUAL OVERRIDE

DE

LTA P

OW

ER

CO

BODY WEIGHT: .39 lbs (.18 kg)

.281 [7.1] DIA. MTG. HOLE2X

2.10 [53.5]

.25 [6.4]

1.50 [38.1]

2.00 [50.8]

1.75 [44.5]2.00

[50.8]

.50 [12.7]

1.52 [38.5]

#6 SAE PORT2X

.25 [6.4]

2.04 [51.8]

1.13 [28.6]

1.25 [31.7]

.63 [15.9]

DE

LTA P

OW

ER

CO

Page 10: SOLENOID OPERATED DIRECTIONAL … 1000 38 69 7/8-14 DE-S2F SD18 2 WAY 2 POSITION NORMALLY CLOSED POPPET VALVES SLID PRATD DIRTIAL TRLS Page SD3 Via Malavolti, 36 • 41122 Modena •

SOLENOID OPERATED DIRECTIONAL CONTROLS

Page SD10

Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512 mail: [email protected] • www.tecnord.com

4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 mail: [email protected] • www.delta-power.com

WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken without independent study, evaluation, and testing for suitability.

W 20 / 2018

HB-S2A PILOT OPERATED POPPET, 2 WAY NORMALLY CLOSED

DESCRIPTION8 size, 3/4-16 thread, “Power” series, solenoid operated, 2 way normally closed, pilot operated poppet valve with reverse flow de-energized.

OPERATIONWhen de-energized the HB-S2A blocks flow from (1) to (2) and allows reverse flow from (2) to (1). When energized the valve allows flow from (1) to (2) and restricts flow from (2) to (1).OPERATION OF MANUAL OVERRIDE OPTION: to override, turn the manual override screw counterclockwise. To release, turn the manual override screw clockwise.

FEATURES • Hardened parts for long life.• Efficient wet-armature construction.• Cartridges are voltage interchangeable.• Manual override option.• Industry common cavity.• Unitized, molded coil design.• Continuous duty rated solenoid.• Optional coil voltages and terminations.

Nominal Flow 12 GPM (45 LPM)Rated Operating Pressure 5000 PSI (345 bar)Typical Internal Leakage 0-5 drops/min at 5000 PSI(150 SSU) (345 bar)Viscosity Range 36 to 3000 SSU (3 to 647 cSt)Filtration ISO 18/16/13Media Operating Temp. Range -40° to 210°F (-40° to 100°C) BUNA seals -4° to 250°F (-20° to 120°C) VITON sealsWeight .29 lbs (.13 kg)Operating Fluid Media General Purpose Hydraulic FluidCartridge Torque Requirements 35 ft-lbs (47 Nm)Coil Nut Torque Requirements 4-6 ft-lbs (5.4-8.1 Nm)Cavity POWER 2WCavity Tools Kit 40500005Seal Kit 21191100

Actual Test Data (Cartridge Only)

VALVE SPECIFICATIONS

Pre

ssur

e D

rop

(bar

)

Pre

ssur

e D

rop

(PS

I)

Flow (LPM)

Flow (GPM)

Port 1 to 2 (eng) Port 2 to 1 (de-eng)

PERFORMANCE

HYDRAULIC SYMBOL

Page 11: SOLENOID OPERATED DIRECTIONAL … 1000 38 69 7/8-14 DE-S2F SD18 2 WAY 2 POSITION NORMALLY CLOSED POPPET VALVES SLID PRATD DIRTIAL TRLS Page SD3 Via Malavolti, 36 • 41122 Modena •

SOLENOID OPERATED DIRECTIONAL CONTROLS

Page SD11

Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512 mail: [email protected] • www.tecnord.com

4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 mail: [email protected] • www.delta-power.com

WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken without independent study, evaluation, and testing for suitability.

W 2

0 /

2018

DIMENSIONS

ORDERING INFORMATION

OPTIONS BODIESBuna Standard 00 Blank Without BodyViton Standard V0 N 1/4 NPTF PortsBuna, Override 0M S #6 SAE PortsViton, Override VM

Buna, Screen A0 VOLTAGEViton, Screen W0 06 6 VDC

Buna, Screen, Override B4 12 12 VDCViton, Screen, Override V4 24 24 VDC

36 36 VDCNote: use screen only if flow 48 48 VDC

direction is from (1) to (2) 25 24 VAC11 120 VAC22 220 VAC44 440 VAC

“P” COIL TERMINATION IMMERSION PROOF “I” COIL TERMINATION

DL Double Lead SS Single Spade IA “I” Coil AMP Superseal - IntegralDT Deutsch on Leads DT04-2P DS Double Spade ID “I” Coil Deutsch - Integral DT04-2PML Metri-Pack on Leads HC DIN 43650 (Hirschmann) - (AC&DC) IJ “I” Coil AMP Jr. Timer - IntegralPL Packard on Leads CL Conduit Lead - (AC Only) IM “I” Coil Metri-Pack - IntegralWL Weatherpack on Leads DI Deutsch - Integral DT04-2P

For Optional Coil Terminations See Coil Section

HB-S2A – – – – Approximate Coil Weight: .42 lbs (.19 kg)

“P” COIL IMMERSION PROOF “I” COIL

Note: Aluminum Body Not durability rated for 5000 PSI (345 bar), consult factory for high pressure body options.

Page 12: SOLENOID OPERATED DIRECTIONAL … 1000 38 69 7/8-14 DE-S2F SD18 2 WAY 2 POSITION NORMALLY CLOSED POPPET VALVES SLID PRATD DIRTIAL TRLS Page SD3 Via Malavolti, 36 • 41122 Modena •

SOLENOID OPERATED DIRECTIONAL CONTROLS

Page SD12

Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512 mail: [email protected] • www.tecnord.com

4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 mail: [email protected] • www.delta-power.com

WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken without independent study, evaluation, and testing for suitability.

W 20 / 2018

PB-S2F PILOT OPERATED POPPET, 2 WAY NORMALLY CLOSED, SOFT SEAT

DESCRIPTION8 size, 3/4-16 thread, “Power” series, solenoid operated, 2 way normally closed, pilot operated soft seat poppet valve with reverse flow de-energized.

OPERATIONWhen de-energized the PB-S2F blocks flow from (1) to (2) and allows reverse flow from (2) to (1). When energized the valve allows flow from (1) to (2) and restrict flow from (2) to (1).OPERATION OF MANUAL OVERRIDE OPTION: to override, pull knob out. On the detented version, after pulling knob out twist 180 degrees and release. The valve will remain in that position.

FEATURES • Soft seat for ultra low leakage.• Efficient wet-armature construction.• Cartridges are voltage interchangeable.• Manual override option.• Industry common cavity.• Unitized, molded coil design.• Continuous duty rated solenoid.• Optional coil voltages and terminations.• Optional “I” Coil: Weatherproof, Thermal Shock, Immersion Safe.

Maximum Flow 6 GPM (23 LPM)Rated Operating Pressure 2500 PSI (172 bar)Typical Internal Leakage (150 SSU) NegligibleViscosity Range 36 to 3000 SSU (3 to 647 cSt)Filtration ISO 18/16/13Media Operating Temp. Range -35° to 200°F (-37° to 93°C)Weight .19 lbs (.08 kg)Operating Fluid Media General Purpose Hydraulic FluidCartridge Torque Requirements 25 ft-lbs (34 Nm)Coil Nut Torque Requirements 4-6 ft-lbs (5.4-8.1 Nm)Cavity POWER 2WCavity Tools Kit (form tool, reamer, tap) 40500005Seal Kit 21191100

VALVE SPECIFICATIONS

Actual Test Data (Cartridge Only)

0

50

100

150

200

250

300

0 2 4 6 8 10 12

Flow (GPM)

0

5

10

15

20

0 10 20 30 40Flow (LPM)

Port 1 to 2 (eng) Port 2 to 1 (de-eng)

Pre

ssur

e D

rop

(PS

I)

Pre

ssur

e D

rop

(bar

)

Operational shift limit is 6 GPM (23 LPM).For shifted performance consult chart.

PERFORMANCE

HYDRAULIC SYMBOL

2

1

Page 13: SOLENOID OPERATED DIRECTIONAL … 1000 38 69 7/8-14 DE-S2F SD18 2 WAY 2 POSITION NORMALLY CLOSED POPPET VALVES SLID PRATD DIRTIAL TRLS Page SD3 Via Malavolti, 36 • 41122 Modena •

SOLENOID OPERATED DIRECTIONAL CONTROLS

Page SD13

Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512 mail: [email protected] • www.tecnord.com

4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 mail: [email protected] • www.delta-power.com

WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken without independent study, evaluation, and testing for suitability.

W 2

0 /

2018

OPTIONS BODIESBuna Standard 00 Blank Without BodyViton Standard V0 N 1/4 NPTF Ports

Buna, Override, Detent 0M S #6 SAE PortsViton, Override, Detent VM

Buna, Screen A0Viton, Screen W0

Buna, Override, Non-Detent B1Viton, Override, Non-Detent V1 VOLTAGE

Buna, Screen, Override, Non-Detent B3 06 6 VDCViton, Screen, Override, Non-Detent V3 12 12 VDC

Buna, Screen, Override, Detent B4 24 24 VDCViton, Screen, Override, Detent V4 36 36 VDC

48 48 VDCNote: use screen only if flow 25 24 VAC

direction is from (1) to (2) 11 120 VAC22 220 VAC

“P” COIL TERMINATION 44 440 VAC(All DC Except as Noted)

IMMERSION PROOF “P” TYPEDL Double Lead SS Single Spade IA “I” Coil AMP Superseal - IntegralDT Deutsch on Leads DT04-2P DS Double Spade ID “I” Coil Deutsch - Integral DT04-2PML Metri-Pack on Leads HC DIN 43650 (Hirschmann) - (AC&DC) IJ “I” Coil AMP Jr. Timer - IntegralPL Packard on Leads CL Conduit Lead - (AC Only) IM “I” Coil Metri-Pack - IntegralWL Weatherpack on Leads DI Deutsch - Integral DT04-2P

PB-S2F – – – –

DIMENSIONS

ORDERING INFORMATIONApproximate Coil Weight: .42 lbs (.19 kg)

SEE COIL DATAFOR TERMINATIONS

.87 [22.1] HEX

3/4-16 UNF-2ATHREAD

2.90 [73.6]

1.09 [27.6]

2.13 [54.2]

1.25 [31.7]

1.54 [39.1]

.75 [19.1]

HEX NUT

STANDARD

MANUAL OVERRIDE

DE

LTA P

OW

ER

CO

BODY WEIGHT: .39 lbs (.18 kg)

.281 [7.1] DIA. MTG. HOLE2X

2.10 [53.5]

.25 [6.4]

1.50 [38.1]

2.00 [50.8]

1.75 [44.5]2.00

[50.8]

.50 [12.7]

1.52 [38.5]

#6 SAE PORT2X

.25 [6.4]

2.04 [51.8]

1.13 [28.6]

1.25 [31.7]

.63 [15.9]

DE

LTA P

OW

ER

CO

Page 14: SOLENOID OPERATED DIRECTIONAL … 1000 38 69 7/8-14 DE-S2F SD18 2 WAY 2 POSITION NORMALLY CLOSED POPPET VALVES SLID PRATD DIRTIAL TRLS Page SD3 Via Malavolti, 36 • 41122 Modena •

SOLENOID OPERATED DIRECTIONAL CONTROLS

Page SD14

Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512 mail: [email protected] • www.tecnord.com

4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 mail: [email protected] • www.delta-power.com

WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken without independent study, evaluation, and testing for suitability.

W 20 / 2018

DE-S2A PILOT OPERATED POPPET, 2 WAY NORMALLY CLOSED

DESCRIPTION10 size, 7/8-14 thread, “Delta” series, solenoid operated, 2 way normally closed, pilot operated poppet valve with reverse flow de-energized.

OPERATIONWhen de-energized the DE-S2A blocks flow from (1) to (2) and allows reverse flow from (2) to (1). When energized the valve allows flow from (1) to (2) and restricts flow from (2) to (1).OPERATION OF MANUAL OVERRIDE OPTION: to override, turn the manual override screw counterclockwise. To release turn the manual override screw clockwise.

FEATURES • Hardened parts for long life.• Efficient wet-armature construction.• Cartridges are voltage interchangeable.• Manual override option.• Industry common cavity.• Unitized, molded coil design.• Continuous duty rated solenoid.• Optional coil voltages and terminations.• Optional “I” Coil: Weatherproof, Thermal Shock, Immersion Safe.

Nominal Flow 15 GPM (57 LPM)Rated Operating Pressure 3500 PSI (241 bar)Typical Internal Leakage (150 SSU) 0-5 drops/minViscosity Range 36 to 3000 SSU (3 to 647 cSt)Filtration ISO 18/16/13Media Operating Temp. Range -40° to 250°F (-40° to 120°C)Weight .27 lbs (.12 kg)Operating Fluid Media General Purpose Hydraulic FluidCartridge Torque Requirements 30 ft-lbs (40.6 Nm)Coil Nut Torque Requirements 4-6 ft-lbs (5.4-8.1 Nm)Cavity DELTA 2WCavity Tools Kit (form tool, reamer, tap) 40500000Seal Kit 21191200

VALVE SPECIFICATIONS

Actual Test Data (Cartridge Only)

0

50

100

150

200

250

0 5 10 15 20Flow (GPM)

0

5

10

15

0 25 50 75Flow (LPM)

Port 1 to 2 (eng) Port 2 to 1 (de-eng)

Pre

ssur

e D

rop

(PS

I)

Pre

ssur

e D

rop

(bar

)

PERFORMANCE

HYDRAULIC SYMBOL

2

1

Page 15: SOLENOID OPERATED DIRECTIONAL … 1000 38 69 7/8-14 DE-S2F SD18 2 WAY 2 POSITION NORMALLY CLOSED POPPET VALVES SLID PRATD DIRTIAL TRLS Page SD3 Via Malavolti, 36 • 41122 Modena •

SOLENOID OPERATED DIRECTIONAL CONTROLS

Page SD15

Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512 mail: [email protected] • www.tecnord.com

4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 mail: [email protected] • www.delta-power.com

WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken without independent study, evaluation, and testing for suitability.

W 2

0 /

2018

DIMENSIONS

ORDERING INFORMATIONApproximate Coil Weight: .74 lbs (.33 kg)

OPTIONS BODIESBuna Standard 00 Blank Without BodyViton Standard V0 N 3/8 NPTF Ports

Buna, Override, Detent 0M S #8 SAE PortsViton, Override, Detent VM

Buna, Screen A0Viton, Screen W0

Buna, Override, Non-Detent B1Viton, Override, Non-Detent V1 VOLTAGE

Buna, Screen, Override, Non-Detent B3 06 6 VDCViton, Screen, Override, Non-Detent V3 12 12 VDC

Buna, Screen, Override, Detent B4 24 24 VDCViton, Screen, Override, Detent V4 36 36 VDC

48 48 VDCNote: use screen only if flow 25 24 VAC

direction is from (1) to (2) 11 120 VAC22 220 VAC

“D” COIL TERMINATION 44 440 VAC(All DC Except as Noted)

IMMERSION PROOF “D” TYPEDL Double Lead SS Single Spade IA “I” Coil AMP Superseal - IntegralDT Deutsch on Leads DT04-2P DS Double Spade ID “I” Coil Deutsch - Integral DT04-2PML Metri-Pack on Leads HC DIN 43650 (Hirschmann) - (AC&DC) IJ “I” Coil AMP Jr. Timer - IntegralPL Packard on Leads CL Conduit Lead - (AC Only) IM “I” Coil Metri-Pack - IntegralWL Weatherpack on Leads DI Deutsch - Integral DT04-2P

DE-S2A – – – –

2.35 [59.6]

1.25 [31.7]

.22 [5.6] 7/8-14 UNF 2A

THREAD

1.00 [25.4] HEX

1.56 [39.6]

1.84 [46.6]

SEE COIL DATAFOR TERMINATIONS

DE

LTA PO

WE

R C

O.

3.35 [85.0]

.75 [19.1]

HEX NUT

MANUAL OVERRIDE

STANDARD 7/16-20 UNF 2ATHREAD

.48 [12.2]

#8 SAE PORTS2X

.28 [7.1] DIA.MTG. HOLES2X

1.59 [40.4]

1.63 [41.4]

.63 [16.0]

2.32 [58.8]

2.13 [54.1]

.75 [19.1]

1.75 [44.5]

2.00 [50.8]

.13 [3.2]

1.50 [38.1]

.81 [20.6] D

ELTA

PO

WE

R C

O.

BODY WEIGHT: .47 lbs (.21 kg)

Page 16: SOLENOID OPERATED DIRECTIONAL … 1000 38 69 7/8-14 DE-S2F SD18 2 WAY 2 POSITION NORMALLY CLOSED POPPET VALVES SLID PRATD DIRTIAL TRLS Page SD3 Via Malavolti, 36 • 41122 Modena •

SOLENOID OPERATED DIRECTIONAL CONTROLS

Page SD16

Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512 mail: [email protected] • www.tecnord.com

4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 mail: [email protected] • www.delta-power.com

WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken without independent study, evaluation, and testing for suitability.

W 20 / 2018

HE-S2A PILOT OPERATED POPPET, 2 WAY NORMALLY CLOSED

DESCRIPTION“High Pressure” 10 size, 7/8-14 thread, “Delta” series, solenoid operated, 2 way normally closed, pilot operated poppet valve with reverse flow de-energized.

OPERATIONWhen de-energized the HE-S2A blocks flow from (1) to (2) and allows reverse flow from (2) to (1). When energized the valve allows flow from (1) to (2) and restricts flow from (2) to (1).

FEATURES • Hardened parts for long life.• Efficient wet-armature construction.• Cartridges are voltage interchangeable.• Industry common cavity.• Unitized, molded coil design.• Continuous duty rated solenoid.• Optional coil voltages and terminations.• Optional “I” Coil: Weatherproof, Thermal Shock, Immersion Safe.

Nominal Flow 15 GPM (57 LPM)Rated Operating Pressure 4000 PSI (276 bar)Typical Internal Leakage (150 SSU) 0-5 drops/minViscosity Range 36 to 3000 SSU (3 to 647 cSt)Filtration ISO 18/16/13Media Operating Temp. Range -40° to 250°F (-40° to 120°C)Weight .39 lbs (.17 kg)Operating Fluid Media General Purpose Hydraulic FluidCartridge Torque Requirements 50 ft-lbs (67.8 Nm)Coil Nut Torque Requirements 4-6 ft-lbs (5.4-8.1 Nm)Cavity DELTA 2WCavity Tools Kit (form tool, reamer, tap) 40500000Seal Kit 21191200

Actual Test Data (Cartridge Only)

VALVE SPECIFICATIONS

0

50

100

150

200

250

0 5 10 15 20Flow (GPM)

0

5

10

15

0 25 50 75

Flow (LPM)

Port 1 to 2 (eng) Port 2 to 1 (de-eng)

Pre

ssur

e D

rop

(bar

)

Pre

ssur

e D

rop

(PS

I)

Uses “L” Coils.

PERFORMANCE

HYDRAULIC SYMBOL

2

1

Page 17: SOLENOID OPERATED DIRECTIONAL … 1000 38 69 7/8-14 DE-S2F SD18 2 WAY 2 POSITION NORMALLY CLOSED POPPET VALVES SLID PRATD DIRTIAL TRLS Page SD3 Via Malavolti, 36 • 41122 Modena •

SOLENOID OPERATED DIRECTIONAL CONTROLS

Page SD17

Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512 mail: [email protected] • www.tecnord.com

4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 mail: [email protected] • www.delta-power.com

WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken without independent study, evaluation, and testing for suitability.

W 2

0 /

2018

Note: Aluminum, NOT durability rated for 4000 PSI. Consult factory for body options.

HE-S2A – – – –

DIMENSIONS

ORDERING INFORMATIONApproximate Coil Weight: .68 lbs (.31 kg)

OPTIONS BODIESBuna Standard 00 Blank Without BodyViton Standard V0 N 3/8 NPTF Ports

S #8 SAE Ports

VOLTAGE06 6 VDC12 12 VDC24 24 VDC36 36 VDC48 48 VDC25 24 VAC11 120 VAC22 220 VAC

“L” COIL TERMINATION 44 440 VAC(All DC Except as Noted)

IMMERSION PROOF “D” TYPEDL Double Lead SS Single Spade IA “I” Coil AMP Superseal - IntegralDT Deutsch on Leads DT04-2P DS Double Spade ID “I” Coil Deutsch - Integral DT04-2PML Metri-Pack on Leads HC DIN 43650 (Hirschmann) - (AC&DC) IJ “I” Coil AMP Jr. Timer - IntegralPL Packard on Leads CL Conduit Lead - (AC Only) IM “I” Coil Metri-Pack - IntegralWL Weatherpack on Leads DI Deutsch - Integral DT04-2P

DE

LTA P

OW

ER

1.83

[46.6]

.75 [19.1]

HEX NUT

1.25 [31.7]

2.66 [67.5]

3.90 [99.2]

.50 [12.7]

1.00 [25.4] HEX

7/8-14 UNF-2A TH'D

1.56 [39.6]

SEE COIL DATAFOR TERMINATIONS

SOLENOID OPERATED DIRECTIONAL CONTROLS

Page SD17

Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512 mail: [email protected] • www.tecnord.com

4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 mail: [email protected] • www.delta-power.com

WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken without independent study, evaluation, and testing for suitability.

W 1

8 /

2017

Note: Aluminum, NOT durability rated for 4000 PSI. Consult factory for body options.

HE-S2A – – – –

DIMENSIONS

ORDERING INFORMATIONApproximate Coil Weight: .68 lbs (.31 kg)

OPTIONS BODIESBuna Standard 00 Blank Without BodyViton Standard V0 N 3/8 NPTF Ports

S #8 SAE Ports

VOLTAGE06 6 VDC12 12 VDC24 24 VDC36 36 VDC48 48 VDC25 24 VAC11 120 VAC22 220 VAC

“L” COIL TERMINATION 44 440 VAC(All DC Except as Noted)

IMMERSION PROOF “D” TYPEDL Double Lead SS Single Spade IA “I” Coil AMP Superseal - IntegralDT Deutsch on Leads DT04-2P DS Double Spade ID “I” Coil Deutsch - Integral DT04-2PML Metri-Pack on Leads HC DIN 43650 (Hirschmann) - (AC&DC) IJ “I” Coil AMP Jr. Timer - IntegralPL Packard on Leads CL Conduit Lead - (AC Only) IM “I” Coil Metri-Pack - IntegralWL Weatherpack on Leads DI Deutsch - Integral DT04-2P

DE

LTA P

OW

ER

1.83

[46.6]

.75 [19.1]

HEX NUT

1.25 [31.7]

2.66 [67.5]

3.90 [99.2]

.50 [12.7]

1.00 [25.4] HEX

7/8-14 UNF-2A TH'D

1.56 [39.6]

SEE COIL DATAFOR TERMINATIONS

SOLENOID OPERATED DIRECTIONAL CONTROLS Delta Power Company4484 Boeing Drive - Rockford, IL 61109

WARNING: The specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken without independent study, evaluation, and testing for suitability.

Phone: (815) 397-6628 Fax: (815) 397-2526 E-mail: [email protected]

DIMENSIONS

ORDERING INFORMATION HE-S2A - - - -

OPTIONS BODIES Note: Aluminum, NOT durability rated for

Buna Standard 00 Blank Without Body 4000 PSI. Consult factory options. Viton Standard V0 N 3/8 NPTF Ports

S #8 SAE Ports VOLTAGE 06 6 VDC

12 12 VDC 24 24 VDC

36 36 VDC 48 48 VAC 25 25 VAC 11 120 VAC 22 220 VAC 44 440 VAC

“L” COIL TERMINATION (All DC Except as Noted)

IMMERSION PROOF “D” TYPE DL Double Lead SS Single Spade IA “I” Coil AMP Superseal - Integral DT Deutsch on Leads DT04-2P DS Double Spade ID “I” Coil Deutsch – Integral DT04-2P ML Metri-Pack on Leads HC DIN 43650 (Hirschman) – (AC & DC) IJ “I” Coil AMP Jr. Timer - Integral PL Packard on Leads CL Conduit Lead – (AC Only) IM “I” Coil Metri-Pack – Integral WL Weatherpack on Leads DI Deutsch – Integral DT04-2P

Approximate Coil Weight: .68 lbs. (.31 kg.)

Page 21

Page 18: SOLENOID OPERATED DIRECTIONAL … 1000 38 69 7/8-14 DE-S2F SD18 2 WAY 2 POSITION NORMALLY CLOSED POPPET VALVES SLID PRATD DIRTIAL TRLS Page SD3 Via Malavolti, 36 • 41122 Modena •

SOLENOID OPERATED DIRECTIONAL CONTROLS

Page SD18

Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512 mail: [email protected] • www.tecnord.com

4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 mail: [email protected] • www.delta-power.com

WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken without independent study, evaluation, and testing for suitability.

W 20 / 2018

DE-S2F PILOT OPERATED POPPET, 2 WAY NORMALLY CLOSED, SOFT SEAT

DESCRIPTION10 size, 7/8-14 thread, “Delta” series, solenoid operated, 2 way normally closed, pilot operated soft seat poppet valve with reverse flow de-energized.

OPERATIONWhen de-energized the DE-S2F blocks flow from (1) to (2) and allows reverse flow from (2) to (1). When energized the valve allows flow from (1) to (2) but restricts reverse flow from (2) to (1).OPERATION OF MANUAL OVERRIDE OPTION: to override, pull knob out. On the detented version, afterpulling knob out twist 180 degrees and release. The valve will remain in that position.

FEATURES • Soft seat for ultra low leakage.• Efficient wet-armature construction.• Cartridges are voltage interchangeable.• Manual override option.• Industry common cavity.• Unitized, molded coil design.• Continuous duty rated solenoid.• Optional coil voltages and terminations.• Optional “I” Coil: Weatherproof, Thermal Shock, Immersion Safe.

Nominal Flow 10 GPM (38 LPM)Rated Operating Pressure 1000 PSI (69 bar)Typical Internal Leakage (150 SSU) NegligibleViscosity Range 36 to 3000 SSU (3 to 647 cSt)Filtration ISO 18/16/13Media Operating Temp. Range 32° to 160°F (0° to 70°C)Weight .25 lbs (.11 kg)Operating Fluid Media General Purpose Hydraulic FluidCartridge Torque Requirements 30 ft-lbs (40.6 Nm)Coil Nut Torque Requirements 4-6 ft-lbs (5.4-8.1 Nm)Cavity DELTA 2WCavity Tools Kit (form tool, reamer, tap) 40500000Seal Kit 21191200

VALVE SPECIFICATIONS

Actual Test Data (Cartridge Only)

0

50

100

150

200

0 5 10 15 20Flow (GPM)

Pre

ssur

e D

rop

(PS

I)

0

5

10

0 25 50 75Flow (LPM)

Port 1 to 2 (eng) Port 2 to 1 (de-eng)

Pre

ssur

e D

rop

(bar

)

Operational shift limit 10 GPM (38 LPM). For shifted flow performance consult chart.

PERFORMANCE

HYDRAULIC SYMBOL

2

1

Page 19: SOLENOID OPERATED DIRECTIONAL … 1000 38 69 7/8-14 DE-S2F SD18 2 WAY 2 POSITION NORMALLY CLOSED POPPET VALVES SLID PRATD DIRTIAL TRLS Page SD3 Via Malavolti, 36 • 41122 Modena •

SOLENOID OPERATED DIRECTIONAL CONTROLS

Page SD19

Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512 mail: [email protected] • www.tecnord.com

4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 mail: [email protected] • www.delta-power.com

WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken without independent study, evaluation, and testing for suitability.

W 2

0 /

2018

DIMENSIONS

ORDERING INFORMATIONApproximate Coil Weight: .74 lbs (.33 kg)

OPTIONS BODIESBuna Standard 00 Blank Without BodyViton Standard V0 N 3/8 NPTF Ports

Buna, Override, Detent 0M S #8 SAE PortsViton, Override, Detent VM

Buna, Screen A0Viton, Screen W0

Buna, Override, Non-Detent B1Viton, Override, Non-Detent V1 VOLTAGE

Buna, Screen, Override, Non-Detent B3 06 6 VDCViton, Screen, Override, Non-Detent V3 12 12 VDC

Buna, Screen, Override, Detent B4 24 24 VDCViton, Screen, Override, Detent V4 36 36 VDC

48 48 VDCNote: use screen only if flow 25 24 VAC

direction is from (1) to (2) 11 120 VAC22 220 VAC

“D” COIL TERMINATION 44 440 VAC(All DC Except as Noted)

IMMERSION PROOF “D” TYPEDL Double Lead SS Single Spade IA “I” Coil AMP Superseal - IntegralDT Deutsch on Leads DT04-2P DS Double Spade ID “I” Coil Deutsch - Integral DT04-2PML Metri-Pack on Leads HC DIN 43650 (Hirschmann) - (AC&DC) IJ “I” Coil AMP Jr. Timer - IntegralPL Packard on Leads CL Conduit Lead - (AC Only) IM “I” Coil Metri-Pack - IntegralWL Weatherpack on Leads DI Deutsch - Integral DT04-2P

DE-S2F – – – –

HY

DR

AU

LIC C

O.

.22 [5.6]

1.25 [31.7]

1.56 [39.6]

1.84 [46.6]

SEE COIL DATAFOR TERMINATIONS

.48 [12.2]

7/8-14 UNF 2ATHREAD

12-24 UNC 2ATHREAD

1.00 [25.4] HEX

MANUAL OVERRIDE

2.31 [58.8]

3.35 [85.0]

STANDARD

.75 [19.1]

HEX NUT

HY

DR

AU

LIC C

O.

2.00 [50.8]

.13 [3.2]

.63 [16.0]

1.75 [44.5]

1.63 [41.4]2.13

[54.1]

.81 [20.6]1.50

[38.1]1.59

[40.4]

.75 [19.1]

BODY WEIGHT: .47 lbs (.21 kg)

.281 [7.1] DIA. MTG. HOLES2X

#8 SAE PORTS2X

2.28 [58.0]

Page 20: SOLENOID OPERATED DIRECTIONAL … 1000 38 69 7/8-14 DE-S2F SD18 2 WAY 2 POSITION NORMALLY CLOSED POPPET VALVES SLID PRATD DIRTIAL TRLS Page SD3 Via Malavolti, 36 • 41122 Modena •

SOLENOID OPERATED DIRECTIONAL CONTROLS

Page SD20

Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512 mail: [email protected] • www.tecnord.com

4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 mail: [email protected] • www.delta-power.com

WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken without independent study, evaluation, and testing for suitability.

W 20 / 2018

TT-S2A PILOT OPERATED POPPET, 2 WAY NORMALLY CLOSED

DESCRIPTION12 size, 1 1/16-12 thread, “Tecnord” series, solenoid operated, 2 way normally closed, pilot operated poppet valve with reverse flow de-energized.

OPERATIONWhen de-energized the TT-S2A blocks flow from (1) to (2) and allows reverse flow from (2) to (1). When energized the valve allows flow from (1) to (2) and restricts flow from (2) to (1).OPERATION OF MANUAL OVERRIDE OPTION: to override, pull knob out. On the detented version, after pulling knob out twist 180 degrees and release. The valve will remain in that position.

FEATURES • Hardened parts for long life.• Efficient wet-armature construction.• Cartridges are voltage interchangeable.• Manual override option.• Industry common cavity.• Unitized, molded coil design.• Continuous duty rated solenoid.• Optional coil voltages and terminations.• Optional “I” Coil: Weatherproof, Thermal Shock, Immersion Safe.

Nominal Flow 25 GPM (95 LPM)Rated Operating Pressure 3000 PSI (207 bar)Typical Internal Leakage (150 SSU) 0-5 drops/minViscosity Range 36 to 3000 SSU (3 to 647 cSt)Filtration ISO 18/16/13Media Operating Temp. Range -40° to 250°F (-40° to 120°C)Weight .49 lbs (.22 kg)Operating Fluid Media General Purpose Hydraulic FluidCartridge Torque Requirements 70 ft-lbs (94.9 Nm)Coil Nut Torque Requirements 4-6 ft-lbs (5.4-8.1 Nm)Cavity TECNORD 2WCavity Tools Kit (form tool, reamer, tap) 40500032Seal Kit 21191300

VALVE SPECIFICATIONS

Actual Test Data (Cartridge Only)

0

50

100

150

200

250

0 10 20 30 40Flow (GPM)

0

5

10

15

0 25 50 75 100 125 150Flow (LPM)

Port 1 to 2 (eng) Port 2 to 1 (de-eng)

Pres

sure

Dro

p (P

SI)

Pres

sure

Dro

p (b

ar)

PERFORMANCE

HYDRAULIC SYMBOL

2

1

Page 21: SOLENOID OPERATED DIRECTIONAL … 1000 38 69 7/8-14 DE-S2F SD18 2 WAY 2 POSITION NORMALLY CLOSED POPPET VALVES SLID PRATD DIRTIAL TRLS Page SD3 Via Malavolti, 36 • 41122 Modena •

SOLENOID OPERATED DIRECTIONAL CONTROLS

Page SD21

Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512 mail: [email protected] • www.tecnord.com

4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 mail: [email protected] • www.delta-power.com

WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken without independent study, evaluation, and testing for suitability.

W 2

0 /

2018

DIMENSIONS

ORDERING INFORMATIONApproximate Coil Weight: .74 lbs (.33 kg)

OPTIONS BODIESBuna Standard 00 Blank Without BodyViton Standard V0 S #12 SAE Ports

Buna, Override, Detent 0MViton, Override, Detent VM

Buna, Screen A0Viton, Screen W0

Buna, Override, Non-Detent B1Viton, Override, Non-Detent V1 VOLTAGE

Buna, Screen, Override, Non-Detent B3 06 6 VDCViton, Screen, Override, Non-Detent V3 12 12 VDC

Buna, Screen, Override, Detent B4 24 24 VDCViton, Screen, Override, Detent V4 36 36 VDC

48 48 VDCNote: use screen only if flow 25 24 VAC

direction is from (1) to (2) 11 120 VAC22 220 VAC

“D” COIL TERMINATION 44 440 VAC(All DC Except as Noted)

IMMERSION PROOF “D” TYPEDL Double Lead SS Single Spade IA “I” Coil AMP Superseal - IntegralDT Deutsch on Leads DT04-2P DS Double Spade ID “I” Coil Deutsch - Integral DT04-2PML Metri-Pack on Leads HC DIN 43650 (Hirschmann) - (AC&DC) IJ “I” Coil AMP Jr. Timer - IntegralPL Packard on Leads CL Conduit Lead - (AC Only) IM “I” Coil Metri-Pack - IntegralWL Weatherpack on Leads DI Deutsch - Integral DT04-2P

TT-S2A – – – –D

ELTA

PO

WE

R C

O

.36 [9.0]

2.53 [64.4]

.75 [19.1]

HEX NUT1.84

[46.6]

3.52 [89.4]

STANDARD

MANUAL OVERRIDE

.48 [12.2]

7/16-20 UNF-2ATHREAD

1.89 [48.0]

SEE COIL DATAFOR TERMINATION

1.25 [31.8] HEX

1 1/16-12 UNF 2ATHREAD

1.56 [39.6]

DE

LTA P

OW

ER

CO

.88 [22.2]

1.75 [44.5]

1.37 [34.8]

2.25 [57.2]

3.09 [78.5]

1.03 [26.2]

#12 SAE PORTS2X

.41 [10.3] DIA.MTG. HOLES2X.17

[4.3]2.20

[55.9]

2.75 [69.9] BODY WEIGHT: 3.71 lbs (1.68 kg)

.36 [9.2]

2.54 [64.6]

Page 22: SOLENOID OPERATED DIRECTIONAL … 1000 38 69 7/8-14 DE-S2F SD18 2 WAY 2 POSITION NORMALLY CLOSED POPPET VALVES SLID PRATD DIRTIAL TRLS Page SD3 Via Malavolti, 36 • 41122 Modena •

SOLENOID OPERATED DIRECTIONAL CONTROLS

Page SD22

Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512 mail: [email protected] • www.tecnord.com

4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 mail: [email protected] • www.delta-power.com

WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken without independent study, evaluation, and testing for suitability.

W 20 / 2018

SJ-S2A PILOT OPERATED POPPET, 2 WAY NORMALLY CLOSED

DESCRIPTION16 size, 1 5/16-12 thread, “Super” series, solenoid operated, 2 way normally closed, pilot operated poppet valve with reverse flow de-energized.

OPERATIONWhen de-energized the SJ-S2A blocks flow from (1) to (2) and allows reverse flow from (2) to (1). When energized the valve allows flow from (1) to (2) and restricted flow from (2) to (1).OPERATION OF MANUAL OVERRIDE OPTION: to override, pull knob out. On the detented version, after pulling knob out twist 180 degrees and release. The valve will remain in that position.

FEATURES • Hardened parts for long life.• Efficient wet-armature construction.• Cartridges are voltage interchangeable.• Manual override option.• Industry common cavity.• Unitized, molded coil design.• Continuous duty rated solenoid.• Optional coil voltages and terminations.• Optional “I” Coil: Weatherproof, Thermal Shock, Immersion Safe.

Nominal Flow 30 GPM (114 LPM)Rated Operating Pressure 3500 PSI (241 bar)Typical Internal Leakage (150 SSU) 0-10 drops/minViscosity Range 36 to 3000 SSU (3 to 647 cSt)Filtration ISO 18/16/13Media Operating Temp. Range -40° to 250°F (-40° to 120°C)Weight .72 lbs (.32 kg)Operating Fluid Media General Purpose Hydraulic FluidCartridge Torque Requirements 90 ft-lbs (122 Nm)Coil Nut Torque Requirements 4-6 ft-lbs (5.4-8.1 Nm)Cavity SUPER 2WCavity Tools Kit (form tool, reamer, tap) 40500017Seal Kit 21191400

VALVE SPECIFICATIONS

Actual Test Data (Cartridge Only)

0

50

100

150

200

250

0 10 20 30 40Flow (GPM)

0

5

10

15

0 25 50 75 100 125 150Flow (LPM)

Port 1 to 2 (eng) Port 2 to 1 (eng) Port 2 to 1 (de-eng)

Pre

ssur

e D

rop

(bar

)

Pre

ssur

e D

rop

(PS

I)

PERFORMANCE

HYDRAULIC SYMBOL

2

1

Page 23: SOLENOID OPERATED DIRECTIONAL … 1000 38 69 7/8-14 DE-S2F SD18 2 WAY 2 POSITION NORMALLY CLOSED POPPET VALVES SLID PRATD DIRTIAL TRLS Page SD3 Via Malavolti, 36 • 41122 Modena •

SOLENOID OPERATED DIRECTIONAL CONTROLS

Page SD23

Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512 mail: [email protected] • www.tecnord.com

4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 mail: [email protected] • www.delta-power.com

WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken without independent study, evaluation, and testing for suitability.

W 2

0 /

2018

DIMENSIONS

ORDERING INFORMATIONApproximate Coil Weight: .74 lbs (.33 kg)

OPTIONS BODIESBuna Standard 00 Blank Without BodyViton Standard V0 N 3/4 NPT Ports

Buna, Override, Detent 0M S #12 SAE PortsViton, Override, Detent VM

Buna, Override, Non-Detent B1Viton, Override, Non-Detent V1

VOLTAGE06 6 VDC12 12 VDC24 24 VDC36 36 VDC48 48 VDC25 24 VAC11 120 VAC22 220 VAC

“D” COIL TERMINATION 44 440 VAC(All DC Except as Noted)

IMMERSION PROOF “D” TYPEDL Double Lead SS Single Spade IA “I” Coil AMP Superseal - IntegralDT Deutsch on Leads DT04-2P DS Double Spade ID “I” Coil Deutsch - Integral DT04-2PML Metri-Pack on Leads HC DIN 43650 (Hirschmann) - (AC&DC) IJ “I” Coil AMP Jr. Timer - IntegralPL Packard on Leads CL Conduit Lead - (AC Only) IM “I” Coil Metri-Pack - IntegralWL Weatherpack on Leads DI Deutsch - Integral DT04-2P

SJ-S2A – – – –

DE

LTA P

OW

ER

CO

2.59 [65.8]

3.59 [91.1]

1.80 [45.8]

1.56 [39.6]

1.85 [47.1]

.75 [19.1]

HEX NUT

1 5/16-12 UN2A THREAD

1.63 [41.3] HEX

MANUAL OVERRIDE

STANDARD

SEE COIL DATAFOR TERMINATIONS.48

[12.2]

7/16-20 UNF2A THREAD

DE

LTA P

OW

ER

C0

2.56 [65.0]

3.00 [76.2]

.96 [24.4]

2.25 [57.2]

3.00 [76.2]

2.44 [61.9]

1.22 [30.9]

.28 [7.1]

2.00 [50.8]

1.00 [25.4]

#12 SAE PORTS2X

.41 [10.3] DIA.MTG. SLOTS2X

BODY WEIGHT: 1.29 lbs (.58 kg)

Page 24: SOLENOID OPERATED DIRECTIONAL … 1000 38 69 7/8-14 DE-S2F SD18 2 WAY 2 POSITION NORMALLY CLOSED POPPET VALVES SLID PRATD DIRTIAL TRLS Page SD3 Via Malavolti, 36 • 41122 Modena •

SOLENOID OPERATED DIRECTIONAL CONTROLS

Page SD26

Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512 mail: [email protected] • www.tecnord.com

4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 mail: [email protected] • www.delta-power.com

WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken without independent study, evaluation, and testing for suitability.

W 20 / 2018

PB-S2B PILOT OPERATED POPPET, 2 WAY NORMALLY CLOSED

DESCRIPTION8 size, 3/4-16 thread, “Power” series, solenoid operated, 2 way normally closed, pilot operated poppet valve with reverse flow energized and de-energized.

OPERATIONWhen de-energized the PB-S2B blocks flow from (1) to (2) and allows reverse flow from (2) to (1). When energized the valve allows flow from (1) to (2) and (2) to (1).OPERATION OF MANUAL OVERRIDE OPTION: to override, pull knob out. On the detented version, after pulling knob out twist 180 degrees and release. The valve will remain in that position.

FEATURES • Hardened parts for long life.• Efficient wet-armature construction.• Cartridges are voltage interchangeable.• Manual override option.• Industry common cavity.• Unitized, molded coil design.• Continuous duty rated solenoid.• Optional coil voltages and terminations.• Optional “I” Coil: Weatherproof, Thermal Shock, Immersion Safe.

Nominal Flow 8 GPM (30 LPM)Rated Operating Pressure 3500 PSI (241 bar)Typical Internal Leakage (150 SSU) 0-5 drops/minViscosity Range 36 to 3000 SSU (3 to 647 cSt)Filtration ISO 18/16/13Media Operating Temp. Range -40° to 250°F (-40° to 120°C)Weight .20 lbs (.09 kg)Operating Fluid Media General Purpose Hydraulic FluidCartridge Torque Requirements 25 ft-lbs (34 Nm)Coil Nut Torque Requirements 4-6 ft-lbs (5.4-8.1 Nm)Cavity POWER 2WCavity Tools Kit (form tool, reamer, tap) 40500005Seal Kit 21191100

VALVE SPECIFICATIONS

Actual Test Data (Cartridge Only)

0

50

100

150

200

0 2 4 6 8 10 12

Flow (GPM)

Pre

ssur

e D

rop

(PS

I)

0

5

10

0 10 20 30 40Flow (LPM)

Pre

ssur

e D

rop

(bar

)

Port 1 to 2 (eng) Port 2 to 1 (eng) Port 2 to 1 (de-eng)

PERFORMANCE

HYDRAULIC SYMBOL

2

1

Page 25: SOLENOID OPERATED DIRECTIONAL … 1000 38 69 7/8-14 DE-S2F SD18 2 WAY 2 POSITION NORMALLY CLOSED POPPET VALVES SLID PRATD DIRTIAL TRLS Page SD3 Via Malavolti, 36 • 41122 Modena •

SOLENOID OPERATED DIRECTIONAL CONTROLS

Page SD27

Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512 mail: [email protected] • www.tecnord.com

4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 mail: [email protected] • www.delta-power.com

WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken without independent study, evaluation, and testing for suitability.

W 2

0 /

2018

DIMENSIONS

ORDERING INFORMATIONApproximate Coil Weight: .42 lbs (.19 kg)

OPTIONS BODIESBuna Standard 00 Blank Without BodyViton Standard V0 N 1/4 NPTF Ports

Buna, Override, Detent 0M S #6 SAE PortsViton, Override, Detent VM

Buna, Screen A0Viton, Screen W0

Buna, Override, Non-Detent B1Viton, Override, Non-Detent V1 VOLTAGE

Buna, Screen, Override, Non-Detent B3 06 6 VDCViton, Screen, Override, Non-Detent V3 12 12 VDC

Buna, Screen, Override, Detent B4 24 24 VDCViton, Screen, Override, Detent V4 36 36 VDC

48 48 VDCNote: use screen only if flow 25 24 VAC

direction is from (1) to (2) 11 120 VAC22 220 VAC

“P” COIL TERMINATION 44 440 VAC(All DC Except as Noted)

IMMERSION PROOF “P” TYPEDL Double Lead SS Single Spade IA “I” Coil AMP Superseal - IntegralDT Deutsch on Leads DT04-2P DS Double Spade ID “I” Coil Deutsch - Integral DT04-2PML Metri-Pack on Leads HC DIN 43650 (Hirschmann) - (AC&DC) IJ “I” Coil AMP Jr. Timer - IntegralPL Packard on Leads CL Conduit Lead - (AC Only) IM “I” Coil Metri-Pack - IntegralWL Weatherpack on Leads DI Deutsch - Integral DT04-2P

PB-S2B – – – –

SEE COIL DATAFOR TERMINATIONS

.87 [22.1] HEX

3/4-16 UNF-2ATHREAD

2.90 [73.6]

1.09 [27.6]

2.13 [54.2]

1.25 [31.7]

1.54 [39.1]

.75 [19.1]

HEX NUT

STANDARD

MANUAL OVERRIDE

DE

LTA P

OW

ER

CO

BODY WEIGHT: .39 lbs (.18 kg)

.281 [7.1] DIA. MTG. HOLE2X

2.10 [53.5]

.25 [6.4]

1.50 [38.1]

2.00 [50.8]

1.75 [44.5]2.00

[50.8]

.50 [12.7]

1.52 [38.5]

#6 SAE PORT2X

.25 [6.4]

2.04 [51.8]

1.13 [28.6]

1.25 [31.7]

.63 [15.9]

DE

LTA P

OW

ER

CO

Page 26: SOLENOID OPERATED DIRECTIONAL … 1000 38 69 7/8-14 DE-S2F SD18 2 WAY 2 POSITION NORMALLY CLOSED POPPET VALVES SLID PRATD DIRTIAL TRLS Page SD3 Via Malavolti, 36 • 41122 Modena •

SOLENOID OPERATED DIRECTIONAL CONTROLS

Page SD28

Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512 mail: [email protected] • www.tecnord.com

4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 mail: [email protected] • www.delta-power.com

WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken without independent study, evaluation, and testing for suitability.

W 20 / 2018

HB-S2B PILOT OPERATED, 2 WAY NORMALLY CLOSED WITH FREE REVERSED FLOW

DESCRIPTION8 size, 3/4-16 thread, “Power” series, solenoid operated, 2 way normally closed, pilot operated poppet valve with reverse flow energized and de-energized.

OPERATIONWhen de-energized the HB-S2B blocks flow from (1) to (2) and allows reverse flow from (2) to (1). When energized the valve allows flow from (1) to (2) and from (2) to (1).MANUAL OVERRIDE OPTION: to override, turn the manual override screw counterclockwise. To release, turn the manual override screw counter-clockwise.

FEATURES • Hardened parts for long life.• Efficient wet-armature construction.• Cartridges are voltage interchangeable.• Industry common cavity.• Unitized, molded coil design.• Continuous duty rated solenoid.• Optional coil voltages and terminations.• Optional “I” Coil: Weatherproof, Thermal Shock, Immersion Safe.• Manual override option.

Nominal Flow 12 GPM (45 LPM)Rated Operating Pressure 5000 PSI (345 bar)Typical Internal Leakage 0-5 drops/min at 5000 PSI(150 SSU) (345 bar)Viscosity Range 36 to 3000 SSU (3 to 647 cSt)Filtration ISO 18/16/13Media Operating Temp. Range -40° to 210°F (-40° to 100°C) BUNA seals -4° to 250°F (-20° to 120°C) VITON sealsWeight .29 lbs (.13 kg)Operating Fluid Media General Purpose Hydraulic FluidCartridge Torque Requirements 35 ft-lbs (47 Nm)Coil Nut Torque Requirements 4-6 ft-lbs (5.4-8.1 Nm)Cavity POWER 2WCavity Tools Kit 40500005Seal Kit 21191100

Actual Test Data (Cartridge Only)

VALVE SPECIFICATIONS

Pre

ssur

e D

rop

(PS

I)

Flow (LPM)

Flow (GPM)

Pre

ssur

e D

rop

(bar

)

PERFORMANCE

HYDRAULIC SYMBOL

Page 27: SOLENOID OPERATED DIRECTIONAL … 1000 38 69 7/8-14 DE-S2F SD18 2 WAY 2 POSITION NORMALLY CLOSED POPPET VALVES SLID PRATD DIRTIAL TRLS Page SD3 Via Malavolti, 36 • 41122 Modena •

SOLENOID OPERATED DIRECTIONAL CONTROLS

Page SD29

Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512 mail: [email protected] • www.tecnord.com

4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 mail: [email protected] • www.delta-power.com

WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken without independent study, evaluation, and testing for suitability.

W 2

0 /

2018

DIMENSIONS

ORDERING INFORMATION

HB-S2B – – – – Approximate Coil Weight: .42 lbs (.19 kg)

“P” COIL IMMERSION PROOF “I” COIL

Note: Aluminum Body Not durability rated for 5000 PSI (345 bar), consult factory for high pressure body options.

OPTIONS BODIESBuna Standard 00 Blank Without BodyViton Standard V0 N 1/4 NPTF PortsBuna, Override 0M S #6 SAE PortsViton, Override VM

Buna, Screen A0 VOLTAGEViton, Screen W0 06 6 VDC

Buna, Screen, Override B4 12 12 VDCViton, Screen, Override V4 24 24 VDC

36 36 VDCNote: use screen only if flow 48 48 VDC

direction is from (1) to (2) 25 24 VAC11 120 VAC22 220 VAC44 440 VAC

“P” COIL TERMINATION IMMERSION PROOF “I” COIL TERMINATION

DL Double Lead SS Single Spade IA “I” Coil AMP Superseal - IntegralDT Deutsch on Leads DT04-2P DS Double Spade ID “I” Coil Deutsch - Integral DT04-2PML Metri-Pack on Leads HC DIN 43650 (Hirschmann) - (AC&DC) IJ “I” Coil AMP Jr. Timer - IntegralPL Packard on Leads CL Conduit Lead - (AC Only) IM “I” Coil Metri-Pack - IntegralWL Weatherpack on Leads DI Deutsch - Integral DT04-2P

For Optional Coil Terminations See Coil Section

Page 28: SOLENOID OPERATED DIRECTIONAL … 1000 38 69 7/8-14 DE-S2F SD18 2 WAY 2 POSITION NORMALLY CLOSED POPPET VALVES SLID PRATD DIRTIAL TRLS Page SD3 Via Malavolti, 36 • 41122 Modena •

SOLENOID OPERATED DIRECTIONAL CONTROLS

Page SD30

Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512 mail: [email protected] • www.tecnord.com

4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 mail: [email protected] • www.delta-power.com

WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken without independent study, evaluation, and testing for suitability.

W 20 / 2018

DE-S2B PILOT OPERATED POPPET, 2 WAY NORMALLY CLOSED

DESCRIPTION10 size, 7/8-14 thread, “Delta” series, solenoid operated, 2 way normally closed, pilot operated poppet valve with reverse flow energized and de-energized.

OPERATIONWhen de-energized the DE-S2B acts as a check valve, allowing flow to pass from (2) to (1), while blocking flow from (1) to (2). When energized the valve opens allowing flow to pass from (1) to (2).OPERATION OF MANUAL OVERRIDE OPTION: too override, pull knob out. On the detented version, after pulling knob out twist 180 degrees and release. The valve will remain in that position.

FEATURES • Hardened parts for long life.• Efficient wet-armature construction.• Cartridges are voltage interchangeable.• Manual override option.• Industry common cavity.• Unitized, molded coil design.• Continuous duty rated solenoid.• Optional coil voltages and terminations.• Optional “I” Coil: Weatherproof, Thermal Shock, Immersion Safe.

Nominal Flow 15 GPM (57 LPM)Rated Operating Pressure 3500 PSI (241 bar)Typical Internal Leakage (150 SSU) 0-5 drops/minViscosity Range 36 to 3000 SSU (3 to 647 cSt)Filtration ISO 18/16/13Media Operating Temp. Range -40° to 250°F (-40° to 120°C)Weight .27 lbs (.12 kg)Operating Fluid Media General Purpose Hydraulic FluidCartridge Torque Requirements 30 ft-lbs (40.6 Nm)Coil Nut Torque Requirements 4-6 ft-lbs (5.4-8.1 Nm)Cavity DELTA 2WCavity Tools Kit (form tool, reamer, tap) 40500000Seal Kit 21191200

VALVE SPECIFICATIONS

Actual Test Data (Cartridge Only)

0

50

100

150

200

250

300

0 5 10 15 20Flow (GPM)

Pre

ssur

e D

rop

(PS

I)

0

5

10

15

20

0 25 50 75Flow (LPM)

Pre

ssur

e D

rop

(bar

)

Port 1 to 2 (eng) Port 2 to 1 (eng) Port 2 to 1 (de-eng)

PERFORMANCE

HYDRAULIC SYMBOL

2

1

Page 29: SOLENOID OPERATED DIRECTIONAL … 1000 38 69 7/8-14 DE-S2F SD18 2 WAY 2 POSITION NORMALLY CLOSED POPPET VALVES SLID PRATD DIRTIAL TRLS Page SD3 Via Malavolti, 36 • 41122 Modena •

SOLENOID OPERATED DIRECTIONAL CONTROLS

Page SD31

Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512 mail: [email protected] • www.tecnord.com

4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 mail: [email protected] • www.delta-power.com

WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken without independent study, evaluation, and testing for suitability.

W 2

0 /

2018

DIMENSIONS

ORDERING INFORMATIONApproximate Coil Weight: .74 lbs (.33 kg)

OPTIONS BODIESBuna Standard 00 Blank Without BodyViton Standard V0 N 3/8 NPTF Ports

Buna, Override, Detent 0M S #8 SAE PortsViton, Override, Detent VM

Buna, Screen A0Viton, Screen W0

Buna, Override, Non-Detent B1Viton, Override, Non-Detent V1 VOLTAGE

Buna, Screen, Override, Non-Detent B3 06 6 VDCViton, Screen, Override, Non-Detent V3 12 12 VDC

Buna, Screen, Override, Detent B4 24 24 VDCViton, Screen, Override, Detent V4 36 36 VDC

48 48 VDCNote: use screen only if flow 25 24 VAC

direction is from (1) to (2) 11 120 VAC22 220 VAC

“D” COIL TERMINATION 44 440 VAC(All DC Except as Noted)

IMMERSION PROOF “D” TYPEDL Double Lead SS Single Spade IA “I” Coil AMP Superseal - IntegralDT Deutsch on Leads DT04-2P DS Double Spade ID “I” Coil Deutsch - Integral DT04-2PML Metri-Pack on Leads HC DIN 43650 (Hirschmann) - (AC&DC) IJ “I” Coil AMP Jr. Timer - IntegralPL Packard on Leads CL Conduit Lead - (AC Only) IM “I” Coil Metri-Pack - IntegralWL Weatherpack on Leads DI Deutsch - Integral DT04-2P

DE

LTA P

OW

ER

CO

.

2.00 [50.8]

.13 [3.2]

.63 [16.0]

1.75 [44.5]

1.63 [41.4]2.13

[54.1]

2.28 [57.9]

.81 [20.6]1.50

[38.1]

BODY WEIGHT: .47 lbs (2.1 kg)

.281 [7.1] DIA.MTG. HOLES2X

#8 SAE PORTS2X

.75 [19.1]

SOLENOID OPERATED DIRECTIONAL CONTROLS

Page SD31

Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512 mail: [email protected] • www.tecnord.com

4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 mail: [email protected] • www.delta-power.com

WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken without independent study, evaluation, and testing for suitability.

W 1

8 /

2017

DIMENSIONS

ORDERING INFORMATIONApproximate Coil Weight: .74 lbs (.33 kg)

OPTIONS BODIESBuna Standard 00 Blank Without BodyViton Standard V0 N 3/8 NPTF Ports

Buna, Override, Detent 0M S #8 SAE PortsViton, Override, Detent VM

Buna, Screen A0Viton, Screen W0

Buna, Override, Non-Detent B1Viton, Override, Non-Detent V1 VOLTAGE

Buna, Screen, Override, Non-Detent B3 06 6 VDCViton, Screen, Override, Non-Detent V3 12 12 VDC

Buna, Screen, Override, Detent B4 24 24 VDCViton, Screen, Override, Detent V4 36 36 VDC

48 48 VDCNote: use screen only if flow 25 24 VAC

direction is from (1) to (2) 11 120 VAC22 220 VAC

“D” COIL TERMINATION 44 440 VAC(All DC Except as Noted)

IMMERSION PROOF “D” TYPEDL Double Lead SS Single Spade IA “I” Coil AMP Superseal - IntegralDT Deutsch on Leads DT04-2P DS Double Spade ID “I” Coil Deutsch - Integral DT04-2PML Metri-Pack on Leads HC DIN 43650 (Hirschmann) - (AC&DC) IJ “I” Coil AMP Jr. Timer - IntegralPL Packard on Leads CL Conduit Lead - (AC Only) IM “I” Coil Metri-Pack - IntegralWL Weatherpack on Leads DI Deutsch - Integral DT04-2P

DE

LTA P

OW

ER

CO

.

2.00 [50.8]

.13 [3.2]

.63 [16.0]

1.75 [44.5]

1.63 [41.4]2.13

[54.1]

2.28 [57.9]

.81 [20.6]1.50

[38.1]

BODY WEIGHT: .47 lbs (2.1 kg)

.281 [7.1] DIA.MTG. HOLES2X

#8 SAE PORTS2X

.75 [19.1]

SOLENOID OPERATED DIRECTIONAL CONTROLS Delta Power Company4484 Boeing Drive - Rockford, IL 61109

WARNING: The specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken without independent study, evaluation, and testing for suitability.

Phone: (815) 397-6628 Fax: (815) 397-2526 E-mail: [email protected]

DIMENSIONS

2.35 [59.6]

1.25 [31.7]

.22 [5.6] 7/8-14 UNF 2 A

THREAD

1.00 [25.4] HEX

1.56 [39.6]

1.84 [46.6]

SEE COI L DATAFOR TERMIN ATIONS

DE

LTA PO

WE

R C

O.

3.35 [85.0]

.75 [19.1]

HEX NUT

MANUAL OVERRIDE

STANDARD 7/16-20 UNF 2 ATHREAD

.48 [12.2]

ORDERING INFORMATION DE-S2B - - - -

OPTIONS BODIES

Buna Standard 00 Blank Without Body Viton Standard V0 N 3/8 NPTF Ports Buna, Override 0M S #8 SAE Ports Viton, Override VM Buna & Screen A0 Viton & Screen W0 VOLTAGE

Buna, Override, Non-detent B1 06 6 VDC Viton, Override, Non-detent V1 12 12 VDC

Buna, Screen, Override, Non-detent B3 24 24 VDC Buna, Screen, Override, Detent B4 36 36 VDC

Viton, Screen, Override, Non-detent V3 48 48 VDC Viton, Screen, Override, Detent V4 25 24 VAC

11 120 VAC 22 220 VAC Note: Use screen only if flow direction

is from (1) to (2). 44 440 VAC

“D” COIL TERMINATION (All DC Except as Noted)

IMMERSION PROOF “D” TYPE DL Double Lead SS Single Spade IA “I” Coil AMP Superseal - Integral DT Deutsch on Leads DT04-2P DS Double Spade ID “I” Coil Deutsch – Integral DT04-2P ML Metri-Pack on Leads HC DIN 43650 (Hirschman) – (AC & DC) IJ “I” Coil AMP Jr. Timer - Integral PL Packard on Leads CL Conduit Lead – (AC Only) IM “I” Coil Metri-Pack – Integral WL Weatherpack on Leads DI Deutsch – Integral DT04-2P

Approximate Coil Weight: .74 lbs (.33 kg.)

Page 33

DE-S2B – – – – DE-S2B – – – –

Page 30: SOLENOID OPERATED DIRECTIONAL … 1000 38 69 7/8-14 DE-S2F SD18 2 WAY 2 POSITION NORMALLY CLOSED POPPET VALVES SLID PRATD DIRTIAL TRLS Page SD3 Via Malavolti, 36 • 41122 Modena •

SOLENOID OPERATED DIRECTIONAL CONTROLS

Page SD34

Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512 mail: [email protected] • www.tecnord.com

4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 mail: [email protected] • www.delta-power.com

WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken without independent study, evaluation, and testing for suitability.

W 20 / 2018

TT-S2B PILOT OPERATED POPPET, 2 WAY NORMALLY CLOSED

DESCRIPTION12 size, 1 1/16-12 thread, “Tecnord” series, solenoid operated, 2 way normally closed, pilot operated poppet valve with reverse flow energized and de-energized.

OPERATIONWhen de-energized the TT-S2B blocks flow from (1) to (2) and allows reverse flow from (2) to (1). When energized the valve allows flow from (1) to (2) and from (2) to (1).OPERATION OF MANUAL OVERRIDE OPTION: to override, pull knob out. On the detented version, after pulling knob out twist 180 degrees and release. The valve will remain in that position.

FEATURES • Hardened parts for long life.• Efficient wet-armature construction.• Cartridges are voltage interchangeable.• Manual override option.• Industry common cavity.• Unitized, molded coil design.• Continuous duty rated solenoid.• Optional coil voltages and terminations.• Optional “I” Coil: Weatherproof, Thermal Shock, Immersion Safe.

Nominal Flow 25 GPM (95 LPM)Rated Operating Pressure 3000 PSI (207 bar)Typical Internal Leakage (150 SSU) 0-5 drops/minViscosity Range 36 to 3000 SSU (3 to 647 cSt)Filtration ISO 18/16/13Media Operating Temp. Range -40° to 250°F (-40° to 120°C)Weight .49 lbs (.22 kg)Operating Fluid Media General Purpose Hydraulic FluidCartridge Torque Requirements 70 ft-lbs (94.9 Nm)Coil Nut Torque Requirements 4-6 ft-lbs (5.4-8.1 Nm)Cavity TECNORD 2WCavity Tools Kit (form tool, reamer, tap) 40500032Seal Kit 21191300

VALVE SPECIFICATIONS

Actual Test Data (Cartridge Only)

0

50

100

150

200

250

0 5 10 15 20 25 30 35Flow (GPM)

Pre

ssur

e D

rop

(PS

I)

0

5

10

15

0 25 50 75 100 125Flow (LPM)

Pre

ssur

e D

rop

(bar

)

Port 1 to 2 (eng) Port 2 to 1 (eng) Port 2 to 1 (de-eng)

PERFORMANCE

HYDRAULIC SYMBOL

2

1

Page 31: SOLENOID OPERATED DIRECTIONAL … 1000 38 69 7/8-14 DE-S2F SD18 2 WAY 2 POSITION NORMALLY CLOSED POPPET VALVES SLID PRATD DIRTIAL TRLS Page SD3 Via Malavolti, 36 • 41122 Modena •

SOLENOID OPERATED DIRECTIONAL CONTROLS

Page SD35

Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512 mail: [email protected] • www.tecnord.com

4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 mail: [email protected] • www.delta-power.com

WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken without independent study, evaluation, and testing for suitability.

W 2

0 /

2018

DIMENSIONS

ORDERING INFORMATIONApproximate Coil Weight: .74 lbs (.33 kg)

OPTIONS BODIESBuna Standard 00 Blank Without BodyViton Standard V0 S #12 SAE Ports

Buna, Override, Detent 0MViton, Override, Detent VM

Buna, Screen A0Viton, Screen W0

Buna, Override, Non-Detent B1Viton, Override, Non-Detent V1 VOLTAGE

Buna, Screen, Override, Non-Detent B3 06 6 VDCViton, Screen, Override, Non-Detent V3 12 12 VDC

Buna, Screen, Override, Detent B4 24 24 VDCViton, Screen, Override, Detent V4 36 36 VDC

48 48 VDCNote: use screen only if flow 25 24 VAC

direction is from (1) to (2) 11 120 VAC22 220 VAC

“D” COIL TERMINATION 44 440 VAC(All DC Except as Noted)

IMMERSION PROOF “D” TYPEDL Double Lead SS Single Spade IA “I” Coil AMP Superseal - IntegralDT Deutsch on Leads DT04-2P DS Double Spade ID “I” Coil Deutsch - Integral DT04-2PML Metri-Pack on Leads HC DIN 43650 (Hirschmann) - (AC&DC) IJ “I” Coil AMP Jr. Timer - IntegralPL Packard on Leads CL Conduit Lead - (AC Only) IM “I” Coil Metri-Pack - IntegralWL Weatherpack on Leads DI Deutsch - Integral DT04-2P

TT-S2B – – – –D

ELTA

PO

WE

R C

O

.36 [9.0]

2.53 [64.4]

.75 [19.1]

HEX NUT1.84

[46.6]

3.52 [89.4]

STANDARD

MANUAL OVERRIDE

.48 [12.2]

7/16-20 UNF-2ATHREAD

1.89 [48.0]

SEE COIL DATAFOR TERMINATION

1.25 [31.8] HEX

1 1/16-12 UNF 2ATHREAD

1.56 [39.6]

DE

LTA P

OW

ER

CO

.88 [22.2]

1.75 [44.5]

1.06 [26.9]

2.25 [57.2]

3.09 [78.5]

1.03 [26.2]

#12 SAE PORTS2X

.41 [10.3] DIA.MTG. HOLES2X.17

[4.3]2.20

[55.9]

2.75 [69.9] BODY WEIGHT: 3.7 lbs (1.7 kg)

.36 [9.2]

2.54 [64.6]

Page 32: SOLENOID OPERATED DIRECTIONAL … 1000 38 69 7/8-14 DE-S2F SD18 2 WAY 2 POSITION NORMALLY CLOSED POPPET VALVES SLID PRATD DIRTIAL TRLS Page SD3 Via Malavolti, 36 • 41122 Modena •

SOLENOID OPERATED DIRECTIONAL CONTROLS

Page SD36

Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512 mail: [email protected] • www.tecnord.com

4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 mail: [email protected] • www.delta-power.com

WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken without independent study, evaluation, and testing for suitability.

W 20 / 2018

HT-S2B PILOT OPERATED POPPET, 2 WAY NORMALLY CLOSED

DESCRIPTION“High pressure” 12 size, 1 1/16-12 thread, “Tecnord” series, solenoid operated, 2 way normally closed, pilot operated poppet valve with reverse flow energized and de-energized.

OPERATIONWhen de-energized the HT-S2B blocks flow from (1) to (2) and allows reverse flow from (2) to (1). When energized the valve allows flow from (1) to (2) and from (2) to (1).

FEATURES • Hardened parts for long life.• Efficient wet-armature construction.• Cartridges are voltage interchangeable.• Industry common cavity.• Unitized, molded coil design.• Continuous duty rated solenoid.• Optional coil voltages and terminations.

Nominal Flow 25 GPM (95 LPM)Rated Operating Pressure 5000 PSI (345 bar)Typical Internal Leakage (150 SSU) 0-8 drops/minViscosity Range 36 to 3000 SSU (3 to 647 cSt)Filtration ISO 18/16/13Media Operating Temp. Range -40° to 250°F (-40° to 120°C)Weight .94 lbs (.43 kg)Operating Fluid Media General Purpose Hydraulic FluidCartridge Torque Requirements 70 ft-lbs (94.9 Nm)Coil Nut Torque Requirements 5-7 ft-lbs (6.8-9.5 Nm)Cavity TECNORD 2WCavity Tools Kit (form tool, reamer, tap) 40500032Seal Kit 21191301

Actual Test Data (Cartridge Only)

VALVE SPECIFICATIONS

0

50

100

150

200

250

0 5 10 15 20 25 30 35

Flow (GPM)

Pre

ssur

e D

rop

(PS

I)

0

5

10

15

0 25 50 75 100 125Flow (LPM)

Pre

ssur

e D

rop

(bar

)

Port 1 to 2 (eng) Port 2 to 1 (eng) Port 2 to 1 (de-eng)

PERFORMANCE

HYDRAULIC SYMBOL

2

1

Page 33: SOLENOID OPERATED DIRECTIONAL … 1000 38 69 7/8-14 DE-S2F SD18 2 WAY 2 POSITION NORMALLY CLOSED POPPET VALVES SLID PRATD DIRTIAL TRLS Page SD3 Via Malavolti, 36 • 41122 Modena •

SOLENOID OPERATED DIRECTIONAL CONTROLS

Page SD37

Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512 mail: [email protected] • www.tecnord.com

4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 mail: [email protected] • www.delta-power.com

WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken without independent study, evaluation, and testing for suitability.

W 2

0 /

2018

OPTIONS BODIESBuna Standard 00 Blank Without BodyViton Standard V0 S #12 SAE PortsBuna, Screen A0Viton, Screen W0

Note: use screen only if flow direction is from (1) to (2)

VOLTAGE06 6 VDC

“T” COIL TERMINATION 12 12 VDC(All DC Except as Noted) 24 24 VDC

Double Lead DL 36 36 VDCDeutsch on Leads DT 48 48 VDC

Metri-Pack on Leads ML 25 24 VACPackard on Leads PL 11 120 VAC

Weatherpack on Leads WL 22 220 VACDouble Spade DS

DIN 43650 (Hirschmann) - (AC&DC) HC

HT-S2B – – – –

DIMENSIONS

ORDERING INFORMATIONApproximate Coil Weight: .89 lbs (.41 kg)

DELTA POWER CO

3.82 [97.0]

1.91 [48.5]

1.16 [29.4]

2.09 [53.2]

1.80 [45.7]

1.25 [31.8] HEX

1 1/16-12 UN2A THREAD

SEE COIL DATAFOR TERMINATIONS

1.00 [25.4]

HEX NUT

DELTA POWER CO

1.76 [44.7]

.88 [22.4]

3.84 [97.6]

3.09 [78.5]

2.75 [69.9]

2.20 [55.9]

1.06 [26.9]

.17 [4.3]

1.03 [26.2]

2.25 [57.2]

BODY WEIGHT: 3.71 lbs (1.68 kg)

.41 [10.3] DIA.MTG. HOLES2X

#12 SAE PORTS2X

1.00 [25.4]

HEX NUT

SEE COIL DATAFOR TERMINATIONS

Page 34: SOLENOID OPERATED DIRECTIONAL … 1000 38 69 7/8-14 DE-S2F SD18 2 WAY 2 POSITION NORMALLY CLOSED POPPET VALVES SLID PRATD DIRTIAL TRLS Page SD3 Via Malavolti, 36 • 41122 Modena •

SOLENOID OPERATED DIRECTIONAL CONTROLS

Page SD38

Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512 mail: [email protected] • www.tecnord.com

4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 mail: [email protected] • www.delta-power.com

WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken without independent study, evaluation, and testing for suitability.

W 20 / 2018

SJ-S2B PILOT OPERATED POPPET, 2 WAY NORMALLY CLOSED

DESCRIPTION16 size, 1 5/16-12 thread, “Super” series, solenoid operated, 2 way normally closed, pilot operated poppet valve with reverse flow energized and de-energized.

OPERATIONWhen de-energized the SJ-S2B blocks flow from (1) to (2) and allows reverse flow from (2) to (1). When energized the valve allows flow from (1) to (2) and from (2) to (1).OPERATION OF MANUAL OVERRIDE OPTION: to override, pull knob out. On the detented version, after pulling knob out twist 180 degrees and release. The valve will remain in that position.

FEATURES • Hardened parts for long life.• Efficient wet-armature construction.• Cartridges are voltage interchangeable.• Manual override option.• Industry common cavity.• Unitized, molded coil design.• Continuous duty rated solenoid.• Optional coil voltages and terminations.• Optional “I” Coil: Weatherproof, Thermal Shock, Immersion Safe.

Nominal Flow 30 GPM (114 LPM)Rated Operating Pressure 3500 PSI (241 bar)Typical Internal Leakage (150 SSU) 0-10 drops/minViscosity Range 36 to 3000 SSU (3 to 647 cSt)Filtration ISO 18/16/13Media Operating Temp. Range -40° to 250°F (-40° to 120°C)Weight .72 lbs (.32 kg)Operating Fluid Media General Purpose Hydraulic FluidCartridge Torque Requirements 90 ft-lbs (122 Nm)Coil Nut Torque Requirements 4-6 ft-lbs (5.4-8.1 Nm)Cavity SUPER 2WCavity Tools Kit (form tool, reamer, tap) 40500017Seal Kit 21191401

VALVE SPECIFICATIONS

Actual Test Data (Cartridge Only)

0

50

100

150

200

250

0 10 20 30 40

Flow (GPM)

Pre

ssur

e D

rop

(PS

I)

0

5

10

15

0 25 50 75 100 125 150Flow (LPM)

Pre

ssur

e D

rop

(bar

)

Port 1 to 2 (eng) Port 2 to 1 (eng) Port 2 to 1 (de-eng)

PERFORMANCE

HYDRAULIC SYMBOL

2

1

Page 35: SOLENOID OPERATED DIRECTIONAL … 1000 38 69 7/8-14 DE-S2F SD18 2 WAY 2 POSITION NORMALLY CLOSED POPPET VALVES SLID PRATD DIRTIAL TRLS Page SD3 Via Malavolti, 36 • 41122 Modena •

SOLENOID OPERATED DIRECTIONAL CONTROLS

Page SD39

Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512 mail: [email protected] • www.tecnord.com

4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 mail: [email protected] • www.delta-power.com

WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken without independent study, evaluation, and testing for suitability.

W 2

0 /

2018

DIMENSIONS

ORDERING INFORMATIONApproximate Coil Weight: .74 lbs (.33 kg)

OPTIONS BODIESBuna Standard 00 Blank Without BodyViton Standard V0 N 3/4 NPT Ports

Buna, Override, Detent 0M S #12 SAE PortsViton, Override, Detent VM

Buna, Screen A0Viton, Screen W0

Buna, Override, Non-Detent B1Viton, Override, Non-Detent V1 VOLTAGE

Buna, Screen, Override, Non-Detent B3 06 6 VDCViton, Screen, Override, Non-Detent V3 12 12 VDC

Buna, Screen, Override, Detent B4 24 24 VDCViton, Screen, Override, Detent V4 36 36 VDC

48 48 VDCNote: use screen only if flow 25 24 VAC

direction is from (1) to (2) 11 120 VAC22 220 VAC

“D” COIL TERMINATION 44 440 VAC(All DC Except as Noted)

IMMERSION PROOF “D” TYPEDL Double Lead SS Single Spade IA “I” Coil AMP Superseal - IntegralDT Deutsch on Leads DT04-2P DS Double Spade ID “I” Coil Deutsch - Integral DT04-2PML Metri-Pack on Leads HC DIN 43650 (Hirschmann) - (AC&DC) IJ “I” Coil AMP Jr. Timer - IntegralPL Packard on Leads CL Conduit Lead - (AC Only) IM “I” Coil Metri-Pack - IntegralWL Weatherpack on Leads DI Deutsch - Integral DT04-2P

SJ-S2B – – – –

DE

LTA P

OW

ER

CO

2.59 [65.8]

3.59 [91.1]

1.80 [45.8]

1.56 [39.6]

1.85 [47.1]

.75 [19.1]

HEX NUT

1 5/16-12 UN2A THREAD

1.63 [41.3] HEX

MANUAL OVERRIDE

STANDARD

SEE COIL DATAFOR TERMINATIONS.48

[12.2]

7/16-20 UNF2A THREAD

DE

LTA P

OW

ER

C0

2.56 [65.0]

3.00 [76.2]

.96 [24.4]

2.25 [57.2]

3.00 [76.2]

2.44 [61.9]

1.22 [30.9]

.28 [7.1]

2.00 [50.8]

1.00 [25.4]

#12 SAE PORTS2X

.41 [10.3] DIA.MTG. SLOTS2X

BODY WEIGHT: 1.29 lbs (.58 kg)

Page 36: SOLENOID OPERATED DIRECTIONAL … 1000 38 69 7/8-14 DE-S2F SD18 2 WAY 2 POSITION NORMALLY CLOSED POPPET VALVES SLID PRATD DIRTIAL TRLS Page SD3 Via Malavolti, 36 • 41122 Modena •

SOLENOID OPERATED DIRECTIONAL CONTROLS

Page SD40

W 20 / 2018

Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512 mail: [email protected] • www.tecnord.com

4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 mail: [email protected] • www.delta-power.com

WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken without independent study, evaluation, and testing for suitability.

Page 37: SOLENOID OPERATED DIRECTIONAL … 1000 38 69 7/8-14 DE-S2F SD18 2 WAY 2 POSITION NORMALLY CLOSED POPPET VALVES SLID PRATD DIRTIAL TRLS Page SD3 Via Malavolti, 36 • 41122 Modena •

SOLENOID OPERATED DIRECTIONAL CONTROLS

Page SD41

W 2

0 /

2018

Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512 mail: [email protected] • www.tecnord.com

4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 mail: [email protected] • www.delta-power.com

WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken without independent study, evaluation, and testing for suitability.

2W2P NORMALLY CLOSED GPM PSI LPM BAR CAVITY MODEL PAGE

0.20 4000 0.76 276 5/8-18 UA-S2E SD42

3 3600 11 250 3/4-16 PB-S2I SD44

3 3000 11 207 7/8-14 DE-S2I SD46

12 5000 45 345 3/4-16 HB-S2L SD48

2 WAY 2 POSITION NORMALLY CLOSED BIDIRECTIONAL POPPET VALVES

TYPICAL SCHEMATIC

Typical application for the S2E, S2I, and S2L is where load holding in both directions is required.

SOLENOID OPERATED DIRECTIONAL CONTROLS

(2)

(1)

(2)

(1)

Page 38: SOLENOID OPERATED DIRECTIONAL … 1000 38 69 7/8-14 DE-S2F SD18 2 WAY 2 POSITION NORMALLY CLOSED POPPET VALVES SLID PRATD DIRTIAL TRLS Page SD3 Via Malavolti, 36 • 41122 Modena •

SOLENOID OPERATED DIRECTIONAL CONTROLS

Page SD42

Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512 mail: [email protected] • www.tecnord.com

4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 mail: [email protected] • www.delta-power.com

WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken without independent study, evaluation, and testing for suitability.

W 20 / 2018

UA-S2E POPPET, 2 WAY, NORMALLY CLOSED, BIDIRECTIONAL

DESCRIPTION7 size, 5/8-18 thread, “Mini” series, solenoid operated, 2 way normally closed, bidirectional poppet valve.

OPERATIONWhen de-energized the UA-S2E blocks flow from (1) to (2) and (2) to (1). When energized, the valve allows flow from (1) to (2) and (2) to (1).

FEATURES • Hardened parts for long life.• Efficient wet-armature construction.• Cartridges are voltage interchangeable.• Industry common cavity.• Unitized, molded coil design.• Continuous duty rated solenoid.• Optional coil voltages and terminations.

Nominal Flow 0.20 GPM (0.76 LPM)Rated Operating Pressure 4000 PSI (276 bar)Typical Internal Leakage (150 SSU) 0-10 drops/minViscosity Range 36 to 3000 SSU (3 to 647 cSt)Filtration ISO 18/16/13Media Operating Temp. Range -40° to 250°F (-40° to 120°C)Weight .18 lbs (.08 kg)Operating Fluid Media General Purpose Hydraulic FluidCartridge Torque Requirements 15 ft-lbs (20.3 Nm)Coil Nut Torque Requirements 4-6 ft-lbs (5.4-8.1 Nm)Cavity MINI 2WCavity Form Tool (Finishing) 40500003Seal Kit 21191003

Actual Test Data (Cartridge Only)

VALVE SPECIFICATIONS

0

50

100

150

200

250

300

0 0.05 0.1 0.15 0.2 0.25Flow (GPM)

0

5

10

15

20

0

Pre

ssur

e D

rop

(PS

I)

0.25 0.5 0.75

Flow (LPM)

Pre

ssur

e D

rop

(BA

R)

Port 1 to 2 & 2 to 1 (eng)

0

50

100

150

200

250

300

0 0.05 0.1 0.15 0.2 0.25Flow (GPM)

0

5

10

15

20

0

Pre

ssur

e D

rop

(PS

I)

0.25 0.5 0.75

Flow (LPM)

Pre

ssur

e D

rop

(BA

R)

Port 1 to 2 & 2 to 1 (eng)

PERFORMANCE

HYDRAULIC SYMBOLUses “P” or “PI” type coils

2

1

Page 39: SOLENOID OPERATED DIRECTIONAL … 1000 38 69 7/8-14 DE-S2F SD18 2 WAY 2 POSITION NORMALLY CLOSED POPPET VALVES SLID PRATD DIRTIAL TRLS Page SD3 Via Malavolti, 36 • 41122 Modena •

SOLENOID OPERATED DIRECTIONAL CONTROLS

Page SD43

Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512 mail: [email protected] • www.tecnord.com

4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 mail: [email protected] • www.delta-power.com

WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken without independent study, evaluation, and testing for suitability.

W 2

0 /

2018

DIMENSIONS

ORDERING INFORMATIONApproximate Coil Weight: .30 lbs (.14 kg)

OPTIONS BODIESBuna Standard 00 Blank Without BodyViton Standard V0 N 1/4 NPTF PortsBuna, Screen A0 S #6 SAE PortsViton, Screen W0

Note: use screen only if flow direction is from (1) to (2)

VOLTAGE06 6 VDC12 12 VDC24 24 VDC36 36 VDC48 48 VDC25 24 VAC11 120 VAC22 220 VAC

“P” COIL TERMINATION 44 440 VAC(All DC Except as Noted)

IMMERSION PROOF “P” TYPEDL Double Lead SS Single Spade IA “I” Coil AMP Superseal - IntegralDT Deutsch on Leads DT04-2P DS Double Spade ID “I” Coil Deutsch - Integral DT04-2PML Metri-Pack on Leads HC DIN 43650 (Hirschmann) - (AC&DC) IJ “I” Coil AMP Jr. Timer - IntegralPL Packard on Leads CL Conduit Lead - (AC Only) IM “I” Coil Metri-Pack - IntegralWL Weatherpack on Leads DI Deutsch - Integral DT04-2P

UA-S2E – – – –

Note: Aluminum, NOT durability rated for 4000 PSI. Consult factory for body options.

Page 40: SOLENOID OPERATED DIRECTIONAL … 1000 38 69 7/8-14 DE-S2F SD18 2 WAY 2 POSITION NORMALLY CLOSED POPPET VALVES SLID PRATD DIRTIAL TRLS Page SD3 Via Malavolti, 36 • 41122 Modena •

SOLENOID OPERATED DIRECTIONAL CONTROLS

Page SD44

Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512 mail: [email protected] • www.tecnord.com

4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 mail: [email protected] • www.delta-power.com

WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken without independent study, evaluation, and testing for suitability.

W 20 / 2018

PB-S2I DIRECT ACTING POPPET, 2 WAY, NORMALLY CLOSED, BIDIRECTIONAL

DESCRIPTION8 size, 3/4-16 thread, “Power” series, solenoid operated, 2 way normally closed, bidirectional poppet valve.

OPERATIONWhen de-energized the PB-S2I blocks flow from (1) to (2) and from (2) to (1). When energized the valve allows flow from (1) to (2) and from (2) to (1).MANUAL OVERRIDE OPTION: to override, turn clockwise the manual override screw. To release, turn the manual override screw counter-clockwise.

FEATURES • Hardened parts for long life.• Efficient wet-armature construction.• Cartridges are voltage interchangeable.• Industry common cavity.• Unitized, molded coil design.• Continuous duty rated solenoid.• Optional coil voltages and terminations.

Nominal Flow 3 GPM (11 LPM)Rated Operating Pressure 3600 PSI (250 bar)Typical Internal Leakage 0-10 drops/min at 3600 PSI(150 SSU) (250 bar)Viscosity Range 36 to 3000 SSU (3 to 647 cSt)Filtration ISO 18/16/13Media Operating Temp. Range -40° to 210°F (-40° to 100°C) BUNA seals -4° to 250°F (-20° to 120°C) VITON sealsWeight .29 lbs (.13 kg)Operating Fluid Media General Purpose Hydraulic FluidCartridge Torque Requirements 25 ft-lbs (34 Nm)Coil Nut Torque Requirements 4-6 ft-lb (5.4-8.1 Nm)Cavity POWER 2WCavity Tools Kit 40500005Seal Kit Buna Kit: 64900222 Viton Kit:64900223

Actual Test Data (Cartridge Only)

PERFORMANCE HYDRAULIC SYMBOL

VALVE SPECIFICATIONS

Flow (GPM)

Pre

ssur

e D

rop

(PS

I)

De-Rating of Pressure vs. FolwFlow (LPM)

Pre

ssur

e D

rop

(bar

)

Flow (GPM)

Pre

ssur

e D

rop

(PS

I)

Flow (LPM)

Pre

ssur

e D

rop

(bar

)

TECNORDSERVOCOMANDI E REGOLAZIONE

For higher pressure and higher flow option for this function see HB-S2L

Page 41: SOLENOID OPERATED DIRECTIONAL … 1000 38 69 7/8-14 DE-S2F SD18 2 WAY 2 POSITION NORMALLY CLOSED POPPET VALVES SLID PRATD DIRTIAL TRLS Page SD3 Via Malavolti, 36 • 41122 Modena •

SOLENOID OPERATED DIRECTIONAL CONTROLS

Page SD45

Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512 mail: [email protected] • www.tecnord.com

4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 mail: [email protected] • www.delta-power.com

WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken without independent study, evaluation, and testing for suitability.

W 2

0 /

2018

DIMENSIONS

ORDERING INFORMATION

OPTIONS BODIESBuna Standard 00 Blank Without BodyViton Standard V0 N 1/4 NPTF Ports

Buna Knob 0K S #6 SAE PortsViton Knob VK

VOLTAGE06 6 VDC12 12 VDC24 24 VDC36 36 VDC48 48 VDC25 24 VAC11 120 VAC22 220 VAC44 440 VAC

“P” COIL TERMINATION IMMERSION PROOF “I” COIL TERMINATION

DL Double Lead SS Single Spade IA “I” Coil AMP Superseal - IntegralDT Deutsch on Leads DT04-2P DS Double Spade ID “I” Coil Deutsch - Integral DT04-2PML Metri-Pack on Leads HC DIN 43650 (Hirschmann) - (AC&DC) IJ “I” Coil AMP Jr. Timer - IntegralPL Packard on Leads CL Conduit Lead - (AC Only) IM “I” Coil Metri-Pack - IntegralWL Weatherpack on Leads DI Deutsch - Integral DT04-2P

For Optional Coil Terminations See Coil Section

PB - S2I – – – – Approximate Coil Weight: .42 lbs (.19 kg)

TECNORDSERVOCOMANDI E REGOLAZIONE

TECNORDSERVOCOMANDI E REGOLAZIONE

“P” COIL IMMERSION PROOF “I” COIL

Page 42: SOLENOID OPERATED DIRECTIONAL … 1000 38 69 7/8-14 DE-S2F SD18 2 WAY 2 POSITION NORMALLY CLOSED POPPET VALVES SLID PRATD DIRTIAL TRLS Page SD3 Via Malavolti, 36 • 41122 Modena •

SOLENOID OPERATED DIRECTIONAL CONTROLS

Page SD46

Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512 mail: [email protected] • www.tecnord.com

4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 mail: [email protected] • www.delta-power.com

WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken without independent study, evaluation, and testing for suitability.

W 20 / 2018

DE-S2I DIRECT ACTING POPPET, 2 WAY, NORMALLY CLOSED, BIDIRECTIONAL

DESCRIPTION10 size, 7/8-14 thread, “Delta” series, solenoid operated, 2 way normally closed, bidirectional poppet valve.

OPERATIONWhen de-energized the DE-S2I blocks flow from (1) to (2) and (2) to (1). When energized the valve allows flow from (1) to (2) and (2) to (1).OPERATION OF MANUAL OVERRIDE OPTION: to override, turn the manual override screw clockwise. To release turn the manual override screw counter-clockwise.

FEATURES • Hardened parts for long life.• Efficient wet-armature construction.• Cartridges are voltage interchangeable.• Manual override option.• Industry common cavity.• Unitized, molded coil design.• Continuous duty rated solenoid.• Optional coil voltages and terminations.• Optional “I” Coil: Weatherproof, Thermal Shock, Immersion Safe.

Nominal Flow 3 GPM (11 LPM)Rated Operating Pressure 3000 PSI (207 bar)Typical Internal Leakage (150 SSU) 0-10 drops/minViscosity Range 36 to 3000 SSU (3 to 647 cSt)Filtration ISO 18/16/13Media Operating Temp. Range -40° to 250°F (-40° to 120°C)Weight .21 lbs. (.09 kg)Operating Fluid Media General Purpose Hydraulic FluidCartridge Torque Requirements 30 ft-lbs (40.6 Nm)Coil Nut Torque Requirements 4-6 ft-lbs (5.4-8.1 Nm)Cavity DELTA 2WCavity Tools Kit (form tool, reamer, tap) 40500000Seal Kit 21191202

SOLENOID OPERATED DIRECTIONAL CONTROLS

Page SD46

Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512 mail: [email protected] • www.tecnord.com

4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 mail: [email protected] • www.delta-power.com

WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken without independent study, evaluation, and testing for suitability.

W 18 / 2017

DE-S2I POPPET, 2 WAY, NORMALLY CLOSED, BIDIRECTIONAL

DESCRIPTION10 size, 7/8-14 thread, “Delta” series, solenoid operated, 2 way normally closed, bidirectional poppet valve.

OPERATIONWhen de-energized the DE-S2I blocks flow from (1) to (2) and (2) to (1). When energized the valve allows flow from (1) to (2) and (2) to (1).OPERATION OF MANUAL OVERRIDE OPTION: to override, turn the manual override screw clockwise. To release turn the manual override screw counter-clockwise.

FEATURES • Hardened parts for long life.• Efficient wet-armature construction.• Cartridges are voltage interchangeable.• Manual override option.• Industry common cavity.• Unitized, molded coil design.• Continuous duty rated solenoid.• Optional coil voltages and terminations.• Optional “I” Coil: Weatherproof, Thermal Shock, Immersion Safe.

Nominal Flow 3 GPM (11 LPM)Rated Operating Pressure 3000 PSI (207 bar)Typical Internal Leakage (150 SSU) 0-10 drops/minViscosity Range 36 to 3000 SSU (3 to 647 cSt)Filtration ISO 18/16/13Media Operating Temp. Range -40° to 250°F (-40° to 120°C)Weight .21 lbs. (.09 kg)Operating Fluid Media General Purpose Hydraulic FluidCartridge Torque Requirements 30 ft-lbs (40.6 Nm)Coil Nut Torque Requirements 4-6 ft-lbs (5.4-8.1 Nm)Cavity DELTA 2WCavity Tools Kit (form tool, reamer, tap) 40500000Seal Kit 21191202

SOLENOID OPERATED DIRECTIONAL CONTROLS Delta Power Company4484 Boeing Drive - Rockford, IL 61109

WARNING: The specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken without independent study, evaluation, and testing for suitability.

Phone: (815) 397-6628 Fax: (815) 397-2526 E-mail: [email protected]

DE-S2I Poppet, 2 Way, Normally Closed, Bi-Directional DESCRIPTION10 size, 7/8-14 thread, “Delta” series, solenoid operated, 2 way normally closed, bi-directional poppet valve.

OPERATION When de-energized the DE-S2I blocks flow from (1) to (2) and (2) to (1). When energized the valve allows flow from (1) to (2) and (2) to (1). OPERATION OF MANUAL OVERRIDE OPTION: To override, turn the manual override screw clockwise. To release turn the manual override screw counter-clockwise.

FEATURES • Hardened parts for long life. • Efficient wet-armature construction. • Cartridges are voltage interchangeable. • Manual override option. • Industry common cavity.• Unitized, molded coil design. • Continuous duty rated solenoid. • Optional coil voltages and terminations. • Optional “I” Coil: Weatherproof, Thermal Shock, Immersion Safe.

HYDRAULIC SYMBOL Higher pressure or higher flow capable, consult factory for options.

For Higher flow see DE-S2L.

PERFORMANCE Actual Test Data (Cartridge Only) VALVE SPECIFICATIONS

Nominal Flow 3 GPM (11 LPM) Rated Operating Pressure 3000 PSI (207 bar) Typical Internal Leakage (150 SSU) 0-10 drops/min

Viscosity Range 36 to 3000 SSU (3 to 647 cSt) Filtration ISO 18/16/13 Media Operating Temperature Range -40° to 250° F (-40° to 120° C)

Weight .21 lbs. (.09 kg) Operating Fluid Media General Purpose Hydraulic Fluid Cartridge Torque Requirements 30 ft-lbs (40.6 Nm)

Coil Nut Torque Requirements 4-6 ft-lbs (5.4-8.1 Nm)

Cavity DELTA 2WCavity Form Tool (Finishing) 40500000 Seal Kit 21191202

0

50

100

150

0 1 2 3 4

Flow (GPM)

Pres

sure

Dro

p (P

SI)

0

5

10

0 5 10 15

Flow (LPM)

Pres

sure

Dro

p (B

AR

)

Port 1 to 2 (eng) Port 2 to 1 (eng)

Page 48

Higher pressure or higher flow capable, consult factory for options. For Higher flow see DE-S2L.

Actual Test Data (Cartridge Only)

PERFORMANCE VALVE SPECIFICATIONS

HYDRAULIC SYMBOL

2

1

For higher flows & pressures use Power Cavity HB-S2L

Actual Test Data (Cartridge Only)

PERFORMANCE VALVE SPECIFICATIONS

HYDRAULIC SYMBOL

2

1

Page 43: SOLENOID OPERATED DIRECTIONAL … 1000 38 69 7/8-14 DE-S2F SD18 2 WAY 2 POSITION NORMALLY CLOSED POPPET VALVES SLID PRATD DIRTIAL TRLS Page SD3 Via Malavolti, 36 • 41122 Modena •

SOLENOID OPERATED DIRECTIONAL CONTROLS

Page SD47

Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512 mail: [email protected] • www.tecnord.com

4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 mail: [email protected] • www.delta-power.com

WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken without independent study, evaluation, and testing for suitability.

W 2

0 /

2018

SOLENOID OPERATED DIRECTIONAL CONTROLS

Page SD47

Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512 mail: [email protected] • www.tecnord.com

4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 mail: [email protected] • www.delta-power.com

WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken without independent study, evaluation, and testing for suitability.

W 1

8 /

2017

SOLENOID OPERATED DIRECTIONAL CONTROLS Delta Power Company4484 Boeing Drive - Rockford, IL 61109

WARNING: The specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken without independent study, evaluation, and testing for suitability.

Phone: (815) 397-6628 Fax: (815) 397-2526 E-mail: [email protected]

DIMENSIONS

ORDERING INFORMATION DE-S2I - - - -

OPTIONS BODIES

Buna Standard 00 Blank Without Body Viton Standard V0 N 3/8 NPTF Ports Buna, Override OM S #8 SAE Ports Viton, Override VM

Buna, Override, Knob OK Viton, Override, Knob VK VOLTAGE

Buna, Screen A0 06 6 VDC Viton, Screen W0 12 12 VDC

Buna, Screen, Override B2 24 24 VDC Viton, Screen, Override V2 36 36 VDC

Buna, Screen, Override, Knob B5 48 48 VDC Viton, Screen, Override, Knob V5 25 24 VAC

11 120 VAC 22 220 VAC Note: Use screen only if flow direction

is from (1) to (2). 44 440 VAC

“D” COIL TERMINATION (All DC Except as Noted)

IMMERSION PROOF “D” TYPE DL Double Lead SS Single Spade IA “I” Coil AMP Superseal - Integral DT Deutsch on Leads DT04-2P DS Double Spade ID “I” Coil Deutsch – Integral DT04-2P ML Metri-Pack on Leads HC DIN 43650 (Hirschman) – (AC & DC) IJ “I” Coil AMP Jr. Timer - Integral PL Packard on Leads CL Conduit Lead – (AC Only) IM “I” Coil Metri-Pack – Integral WL Weatherpack on Leads DI Deutsch – Integral DT04-2P

Approximate Coil Weight: .72 lbs. (.32 kg.)

Page 49

DIMENSIONS

ORDERING INFORMATIONApproximate Coil Weight: .72 lbs (.32 kg)

OPTIONS BODIESBuna Standard 00 Blank Without BodyViton Standard V0 N 3/8 NPT Ports

Buna, Override, Detent 0M S #8 SAE PortsViton, Override, Detent VMBuna, Override, Knob 0KViton, Override, Knob WK

Buna, Screen A0Viton, Screen W0 VOLTAGE

Buna, Screen, Override B2 06 6 VDCViton, Screen, Override V2 12 12 VDC

Buna, Screen, Override, Knob B5 24 24 VDCViton, Screen, Override, Knob V5 36 36 VDC

48 48 VDCNote: use screen only if flow 25 24 VAC

direction is from (1) to (2) 11 120 VAC22 220 VAC

“D” COIL TERMINATION 44 440 VAC(All DC Except as Noted)

IMMERSION PROOF “D” TYPEDL Double Lead SS Single Spade IA “I” Coil AMP Superseal - IntegralDT Deutsch on Leads DT04-2P DS Double Spade ID “I” Coil Deutsch - Integral DT04-2PML Metri-Pack on Leads HC DIN 43650 (Hirschmann) - (AC&DC) IJ “I” Coil AMP Jr. Timer - IntegralPL Packard on Leads CL Conduit Lead - (AC Only) IM “I” Coil Metri-Pack - IntegralWL Weatherpack on Leads DI Deutsch - Integral DT04-2P

DE-S2I – – – –

DIMENSIONS

ORDERING INFORMATIONApproximate Coil Weight: .72 lbs (.32 kg)

OPTIONS BODIESBuna Standard 00 Blank Without BodyViton Standard V0 N 3/8 NPT Ports

Buna, Override, Detent 0M S #8 SAE PortsViton, Override, Detent VMBuna, Override, Knob 0KViton, Override, Knob WK

Buna, Screen A0Viton, Screen W0 VOLTAGE

Buna, Screen, Override B2 06 6 VDCViton, Screen, Override V2 12 12 VDC

Buna, Screen, Override, Knob B5 24 24 VDCViton, Screen, Override, Knob V5 36 36 VDC

48 48 VDCNote: use screen only if flow 25 24 VAC

direction is from (1) to (2) 11 120 VAC22 220 VAC

“D” COIL TERMINATION 44 440 VAC(All DC Except as Noted)

IMMERSION PROOF “D” TYPEDL Double Lead SS Single Spade IA “I” Coil AMP Superseal - IntegralDT Deutsch on Leads DT04-2P DS Double Spade ID “I” Coil Deutsch - Integral DT04-2PML Metri-Pack on Leads HC DIN 43650 (Hirschmann) - (AC&DC) IJ “I” Coil AMP Jr. Timer - IntegralPL Packard on Leads CL Conduit Lead - (AC Only) IM “I” Coil Metri-Pack - IntegralWL Weatherpack on Leads DI Deutsch - Integral DT04-2P

DE-S2I – – – –

Page 44: SOLENOID OPERATED DIRECTIONAL … 1000 38 69 7/8-14 DE-S2F SD18 2 WAY 2 POSITION NORMALLY CLOSED POPPET VALVES SLID PRATD DIRTIAL TRLS Page SD3 Via Malavolti, 36 • 41122 Modena •

SOLENOID OPERATED DIRECTIONAL CONTROLS

Page SD48

Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512 mail: [email protected] • www.tecnord.com

4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 mail: [email protected] • www.delta-power.com

WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken without independent study, evaluation, and testing for suitability.

W 20 / 2018

HB-S2L PILOTED OPERATED POPPET, 2 WAY NORMALLY CLOSED, BIDIRECTIONAL

DESCRIPTION8 size, 3/4-16 thread, “Power” series, solenoid operated, 2 way normally closed, bidirectional poppet valve.

OPERATIONWhen de-energized the HB-S2L blocks flow from (1) to (2) and (2) to (1). When energized the valve allows flow from (1) to (2) and (2) to (1).

FEATURES • Hardened parts for long life.• Efficient wet-armature construction.• Cartridges are voltage interchangeable.• Industry common cavity.• Unitized, molded coil design.• Continuous duty rated solenoid.• Optional coil voltages and terminations.• Optional “I” Coil: Weatherproof, Thermal Shock, Immersion Safe.

Nominal Flow 12 GPM (45 LPM)Rated Operating Pressure 5000 PSI (345 bar)Typical Internal Leakage 0-10 drops/min(150 SSU) Viscosity Range 36 to 3000 SSU (3 to 647 cSt)Filtration ISO 18/16/13Media Operating Temp. Range -40° to 250°F (-40° to 120°C)Weight .26 lbs (.12 kg)Operating Fluid Media General Purpose Hydraulic FluidCartridge Torque Requirements 35 ft-lbs (47 Nm)Coil Nut Torque Requirements 4-6 ft-lbs (5.4-8.1 Nm)Cavity POWER 2WCavity Tools Kit 40500005Seal Kit 21191102

Actual Test Data (Cartridge Only)

VALVE SPECIFICATIONS

TECNORDSERVOCOMANDI E REGOLAZIONE

PERFORMANCE

HYDRAULIC SYMBOL

Page 45: SOLENOID OPERATED DIRECTIONAL … 1000 38 69 7/8-14 DE-S2F SD18 2 WAY 2 POSITION NORMALLY CLOSED POPPET VALVES SLID PRATD DIRTIAL TRLS Page SD3 Via Malavolti, 36 • 41122 Modena •

SOLENOID OPERATED DIRECTIONAL CONTROLS

Page SD49

Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512 mail: [email protected] • www.tecnord.com

4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 mail: [email protected] • www.delta-power.com

WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken without independent study, evaluation, and testing for suitability.

W 2

0 /

2018

DIMENSIONS

TECNORDSERVOCOMANDI E REGOLAZIONE

TECNORDSERVOCOMANDI E REGOLAZIONE

ORDERING INFORMATION

OPTIONSBuna Standard 00Viton Standard V0Buna, Override 0MViton, Override VM

Buna, Screen A0 VOLTAGEViton, Screen W0 06 6 VDC

Buna, Screen, Override B4 12 12 VDCViton, Screen, Override V4 24 24 VDC

36 36 VDCNote: use screen only if flow 48 48 VDC

direction is from (1) to (2) 25 24 VAC11 120 VAC22 220 VAC44 440 VAC

“P” COIL TERMINATION IMMERSION PROOF “I” COIL TERMINATION

DL Double Lead SS Single Spade IA “I” Coil AMP Superseal - IntegralDT Deutsch on Leads DT04-2P DS Double Spade ID “I” Coil Deutsch - Integral DT04-2PML Metri-Pack on Leads HC DIN 43650 (Hirschmann) - (AC&DC) IJ “I” Coil AMP Jr. Timer - IntegralPL Packard on Leads CL Conduit Lead - (AC Only) IM “I” Coil Metri-Pack - IntegralWL Weatherpack on Leads DI Deutsch - Integral DT04-2P

For Optional Coil Terminations See Coil Section

HB - S2L – – – CONSULT FACTORY FOR BODY

Approximate Coil Weight: .42 lbs (.19 kg)

“P” COIL IMMERSION PROOF “I” COIL

Note: Aluminum Body Not durability rated for 5000 PSI (345 bar), consult factory for high pressure body options.

Page 46: SOLENOID OPERATED DIRECTIONAL … 1000 38 69 7/8-14 DE-S2F SD18 2 WAY 2 POSITION NORMALLY CLOSED POPPET VALVES SLID PRATD DIRTIAL TRLS Page SD3 Via Malavolti, 36 • 41122 Modena •

SOLENOID OPERATED DIRECTIONAL CONTROLS

Page SD50

W 20 / 2018

Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512 mail: [email protected] • www.tecnord.com

4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 mail: [email protected] • www.delta-power.com

WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken without independent study, evaluation, and testing for suitability.

Page 47: SOLENOID OPERATED DIRECTIONAL … 1000 38 69 7/8-14 DE-S2F SD18 2 WAY 2 POSITION NORMALLY CLOSED POPPET VALVES SLID PRATD DIRTIAL TRLS Page SD3 Via Malavolti, 36 • 41122 Modena •

SOLENOID OPERATED DIRECTIONAL CONTROLS

Page SD51

W 2

0 /

2018

Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512 mail: [email protected] • www.tecnord.com

4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 mail: [email protected] • www.delta-power.com

WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken without independent study, evaluation, and testing for suitability.

2W2P NORMALLY CLOSED GPM PSI LPM BAR CAVITY MODEL PAGE

1.5 4000 6 276 5/8-18 UA-S2G SD52

8 3000 30 207 3/4-16 PB-S2G SD54

8 3000 30 207 7/8-14 DE-S2G SD56

15 4000 57 276 7/8-14 HE-S2G SD58

2 WAY 2 POSITION NORMALLY CLOSED SPOOL VALVES

Typical application for the S2G is to provide deceleration or unloading of a hydraulic motor.

TYPICAL SCHEMATIC

SOLENOID OPERATED DIRECTIONAL CONTROLS

Page 48: SOLENOID OPERATED DIRECTIONAL … 1000 38 69 7/8-14 DE-S2F SD18 2 WAY 2 POSITION NORMALLY CLOSED POPPET VALVES SLID PRATD DIRTIAL TRLS Page SD3 Via Malavolti, 36 • 41122 Modena •

SOLENOID OPERATED DIRECTIONAL CONTROLS

Page SD52

Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512 mail: [email protected] • www.tecnord.com

4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 mail: [email protected] • www.delta-power.com

WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken without independent study, evaluation, and testing for suitability.

W 20 / 2018

UA-S2G DIRECT ACTING SPOOL, 2 WAY NORMALLY CLOSED

DESCRIPTION7 size, 5/8-18 thread, “Mini” series, solenoid operated, 2 way normally closed, spool valve.

OPERATIONWhen de-energized the UA-S2G blocks flow from (1) to (2) and (2) to (1). When energized, the valve allowsflow from (1) to (2) and (2) to (1).

FEATURES • Efficient wet-armature construction.• Cartridges are voltage interchangeable.• Industry common cavity.• Unitized, molded coil design.• Continuous duty rated solenoid.• Optional coil voltages and terminations.

Nominal Flow 1.5 GPM (6 LPM)Rated Operating Pressure 4000 PSI (276 bar)Typical Internal Leakage (150 SSU) 8 cu in/min (131 ml/min)Viscosity Range 36 to 3000 SSU (3 to 647 cSt)Filtration ISO 18/16/13Media Operating Temp. Range -40° to 250°F (-40° to 120°C)Weight .12 lbs (.05 kg)Operating Fluid Media General Purpose Hydraulic FluidCartridge Torque Requirements 15 ft-lbs (20.3 Nm)Coil Nut Torque Requirements 4-6 ft-lbs (5.4-8.1 Nm)Cavity MINI 2WCavity Form Tool (Finishing) 40500003Seal Kit 21191002

Actual Test Data (Cartridge Only)

VALVE SPECIFICATIONS

0

50

100

0

150

10.5 21.5Flow (GPM)

0

5

10

0 5

Pre

ssur

e D

rop

(PS

I)

Flow (LPM)

Pre

ssur

e D

rop

(BA

R)

Port 1 to 2 (eng) Port 2 to 1 (eng)0

50

100

0

150

10.5 21.5Flow (GPM)

0

5

10

0 5

Pre

ssur

e D

rop

(PS

I)

Flow (LPM)

Pre

ssur

e D

rop

(BA

R)

Port 1 to 2 (eng) Port 2 to 1 (eng)

Uses “P” or “PI” type coils

PERFORMANCE

HYDRAULIC SYMBOL

2

1

Page 49: SOLENOID OPERATED DIRECTIONAL … 1000 38 69 7/8-14 DE-S2F SD18 2 WAY 2 POSITION NORMALLY CLOSED POPPET VALVES SLID PRATD DIRTIAL TRLS Page SD3 Via Malavolti, 36 • 41122 Modena •

SOLENOID OPERATED DIRECTIONAL CONTROLS

Page SD53

Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512 mail: [email protected] • www.tecnord.com

4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 mail: [email protected] • www.delta-power.com

WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken without independent study, evaluation, and testing for suitability.

W 2

0 /

2018

DIMENSIONS

ORDERING INFORMATIONApproximate Coil Weight: .30 lbs (.14 kg)

OPTIONS BODIESBuna Standard 00 Blank Without BodyViton Standard V0 N 1/4 NPTF PortsBuna, Screen A0 S #6 SAE PortsViton, Screen W0

Note: use screen only if flow direction is from (1) to (2)

VOLTAGE06 6 VDC12 12 VDC24 24 VDC36 36 VDC48 48 VDC25 24 VAC11 120 VAC22 220 VAC

“P” COIL TERMINATION 44 440 VAC(All DC Except as Noted)

IMMERSION PROOF “P” TYPEDL Double Lead SS Single Spade IA “I” Coil AMP Superseal - IntegralDT Deutsch on Leads DT04-2P DS Double Spade ID “I” Coil Deutsch - Integral DT04-2PML Metri-Pack on Leads HC DIN 43650 (Hirschmann) - (AC&DC) IJ “I” Coil AMP Jr. Timer - IntegralPL Packard on Leads CL Conduit Lead - (AC Only) IM “I” Coil Metri-Pack - IntegralWL Weatherpack on Leads DI Deutsch - Integral DT04-2P

UA-S2G – – – –

Note: Aluminum, NOT durability rated for 4000 PSI. Consult factory for body options.

Page 50: SOLENOID OPERATED DIRECTIONAL … 1000 38 69 7/8-14 DE-S2F SD18 2 WAY 2 POSITION NORMALLY CLOSED POPPET VALVES SLID PRATD DIRTIAL TRLS Page SD3 Via Malavolti, 36 • 41122 Modena •

SOLENOID OPERATED DIRECTIONAL CONTROLS

Page SD54

Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512 mail: [email protected] • www.tecnord.com

4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 mail: [email protected] • www.delta-power.com

WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken without independent study, evaluation, and testing for suitability.

W 20 / 2018

PB-S2G DIRECT ACTING SPOOL, 2 WAY NORMALLY CLOSED

DESCRIPTION8 size, 3/4-16 thread, “Power” series, solenoid operated, 2 way normally closed, spool valve.

OPERATIONWhen de-energized the PB-S2G blocks flow from (1) to (2) and (2) to (1). When energized the valve allows flow from (1) to (2) and (2) to (1).OPERATION OF MANUAL OVERRIDE OPTION: to override, pull knob out. On the detented version, after pulling knob out twist 180 degrees and release. The valve will remain in that position.

FEATURES • Hardened parts for long life.• Efficient wet-armature construction.• Cartridges are voltage interchangeable.• Manual override option.• Industry common cavity.• Unitized, molded coil design.• Continuous duty rated solenoid.• Optional coil voltages and terminations.• Optional “I” Coil: Weatherproof, Thermal Shock, Immersion Safe.

Nominal Flow 8 GPM (30 LPM) from (1) to (2) 4 GPM (15 LPM) from (2) to (1)Rated Operating Pressure 3000 PSI (207 bar)Typical Internal Leakage (150 SSU) 5 cu in/min (82 ml/min)Viscosity Range 36 to 3000 SSU (3 to 647 cSt)Filtration ISO 18/16/13Media Operating Temp. Range -40° to 250°F (-40° to 120°C)Weight .19 lbs (.09 kg)Operating Fluid Media General Purpose Hydraulic FluidCartridge Torque Requirements 25 ft-lbs (34 Nm)Coil Nut Torque Requirements 4-6 ft-lbs (5.4-8.1 Nm)Cavity POWER 2WCavity Tools Kit (form tool, reamer, tap) 40500005Seal Kit 21191102

Actual Test Data (Cartridge Only)

VALVE SPECIFICATIONS

0

50

100

150

200

250

0 2 4 6 8 10 12Flow (GPM)

Pre

ssur

e D

rop

(PS

I)

0

5

10

15

0 10 20 30 40Flow (LPM)

Pre

ssur

e D

rop

(bar

)

Port 1 to 2 (eng) Port 2 to 1 (eng)

Operational shift limit in (2) to (1) direction is 4 GPM (15 LPM). For shifted flow performance consult chart.

PERFORMANCE

HYDRAULIC SYMBOL

2

1

Page 51: SOLENOID OPERATED DIRECTIONAL … 1000 38 69 7/8-14 DE-S2F SD18 2 WAY 2 POSITION NORMALLY CLOSED POPPET VALVES SLID PRATD DIRTIAL TRLS Page SD3 Via Malavolti, 36 • 41122 Modena •

SOLENOID OPERATED DIRECTIONAL CONTROLS

Page SD55

Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512 mail: [email protected] • www.tecnord.com

4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 mail: [email protected] • www.delta-power.com

WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken without independent study, evaluation, and testing for suitability.

W 2

0 /

2018

DIMENSIONS

ORDERING INFORMATIONApproximate Coil Weight: .42 lbs (.19 kg)

OPTIONS BODIESBuna Standard 00 Blank Without BodyViton Standard V0 N 1/4 NPTF Ports

Buna, Override, Detent 0M S #6 SAE PortsViton, Override, Detent VM

Buna, Screen A0Viton, Screen W0

Buna, Override, Nondetent B1Buna, Override, Nondetent V1 VOLTAGE

Buna, Screen, Override, Nondetent B3 06 6 VDCViton, Screen, Override, Nondetent V3 12 12 VDC

Buna, Screen, Override, Detent B4 24 24 VDCViton, Screen, Override, Detent V4 36 36 VDC

48 48 VDCNote: use screen only if flow 25 24 VAC

direction is from (1) to (2) 11 120 VAC22 220 VAC

“P” COIL TERMINATION 44 440 VAC(All DC Except as Noted)

IMMERSION PROOF “P” TYPEDL Double Lead SS Single Spade IA “I” Coil AMP Superseal - IntegralDT Deutsch on Leads DT04-2P DS Double Spade ID “I” Coil Deutsch - Integral DT04-2PML Metri-Pack on Leads HC DIN 43650 (Hirschmann) - (AC&DC) IJ “I” Coil AMP Jr. Timer - IntegralPL Packard on Leads CL Conduit Lead - (AC Only) IM “I” Coil Metri-Pack - IntegralWL Weatherpack on Leads DI Deutsch - Integral DT04-2P

PB-S2G – – – –

2.00 [50.8]

#6 SAE PORT2X

2.00 [50.8]

1.50 [38.1]

.25 [6.4]

.25 [6.4]

1.52 [38.5]

.28 [7.1] DIA.MTG. HOLES2X

1.75 [44.5]

.50 [12.7]

DE

LTA P

OW

ER

CO

.

BODY WEIGHT: .39 lbs (.18 kg)

1.13 [28.6]

.63 [15.9]

1.25 [31.8]

2.10 [53.3]

SOLENOID OPERATED DIRECTIONAL CONTROLS

Page SD55

Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512 mail: [email protected] • www.tecnord.com

4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 mail: [email protected] • www.delta-power.com

WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken without independent study, evaluation, and testing for suitability.

W 1

8 /

2017

DIMENSIONS

ORDERING INFORMATIONApproximate Coil Weight: .42 lbs (.19 kg)

OPTIONS BODIESBuna Standard 00 Blank Without BodyViton Standard V0 N 1/4 NPTF Ports

Buna, Override, Detent 0M S #6 SAE PortsViton, Override, Detent VM

Buna, Screen A0Viton, Screen W0

Buna, Override, Nondetent B1Buna, Override, Nondetent V1 VOLTAGE

Buna, Screen, Override, Nondetent B3 06 6 VDCViton, Screen, Override, Nondetent V3 12 12 VDC

Buna, Screen, Override, Detent B4 24 24 VDCViton, Screen, Override, Detent V4 36 36 VDC

48 48 VDCNote: use screen only if flow 25 24 VAC

direction is from (1) to (2) 11 120 VAC22 220 VAC

“P” COIL TERMINATION 44 440 VAC(All DC Except as Noted)

IMMERSION PROOF “P” TYPEDL Double Lead SS Single Spade IA “I” Coil AMP Superseal - IntegralDT Deutsch on Leads DT04-2P DS Double Spade ID “I” Coil Deutsch - Integral DT04-2PML Metri-Pack on Leads HC DIN 43650 (Hirschmann) - (AC&DC) IJ “I” Coil AMP Jr. Timer - IntegralPL Packard on Leads CL Conduit Lead - (AC Only) IM “I” Coil Metri-Pack - IntegralWL Weatherpack on Leads DI Deutsch - Integral DT04-2P

PB-S2G – – – –

2.00 [50.8]

#6 SAE PORT2X

2.00 [50.8]

1.50 [38.1]

.25 [6.4]

.25 [6.4]

1.52 [38.5]

.28 [7.1] DIA.MTG. HOLES2X

1.75 [44.5]

.50 [12.7]

DE

LTA P

OW

ER

CO

.

BODY WEIGHT: .39 lbs (.18 kg)

1.13 [28.6]

.63 [15.9]

1.25 [31.8]

2.10 [53.3]

SOLENOID OPERATED DIRECTIONAL CONTROLS Delta Power Company4484 Boeing Drive - Rockford, IL 61109

WARNING: The specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken without independent study, evaluation, and testing for suitability.

Phone: (815) 397-6628 Fax: (815) 397-2526 E-mail: [email protected]

DIMENSIONS

ORDERING INFORMATION PB-S2G - - -

OPTIONS BODIES

Buna Standard 00 Blank Without Body Viton Standard V0 N 1/4 NPTF Ports

Buna, Override, Detent 0M S #6 SAE Ports Viton, Override, Detent VM

Buna, Screen A0 Viton, Screen W0 VOLTAGE

Buna, Override, Nondetent B1 06 6 VDC Viton. Override, Nondetent V1 12 12 VDC

Buna, Screen, Override, Nondetent B3 24 24 VDC Viton, Screen, Override, Nondetent V3 36 36 VDC

Buna, Screen, Override, Detent B4 48 48 VDC Viton, Screen, Override, Detent V4 25 24 VAC

11 120 VAC 22 220 VAC Note: Use screen only if flow direction

is from (1) to (2). 44 440 VAC

“P” COIL TERMINATION (All DC Except as Noted)

IMMERSION PROOF “P” TYPEDL Double Lead SS Single Spade IA “I” Coil AMP Superseal - Integral DT Deutsch on Leads DT04-2P DS Double Spade ID “I” Coil Deutsch – Integral DT04-2P ML Metri-Pack on Leads HC DIN 43650 (Hirschman) – (AC & DC) IJ “I” Coil AMP Jr. Timer - Integral PL Packard on Leads CL Conduit Lead – (AC Only) IM “I” Coil Metri-Pack – Integral WL Weatherpack on Leads DI Deutsch – Integral DT04-2P

Approximate Coil Weight: .42 lbs (.19 kg.)

Page 69

Page 52: SOLENOID OPERATED DIRECTIONAL … 1000 38 69 7/8-14 DE-S2F SD18 2 WAY 2 POSITION NORMALLY CLOSED POPPET VALVES SLID PRATD DIRTIAL TRLS Page SD3 Via Malavolti, 36 • 41122 Modena •

SOLENOID OPERATED DIRECTIONAL CONTROLS

Page SD56

Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512 mail: [email protected] • www.tecnord.com

4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 mail: [email protected] • www.delta-power.com

WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken without independent study, evaluation, and testing for suitability.

W 20 / 2018

DE-S2G DIRECT ACTING SPOOL, 2 WAY NORMALLY CLOSED

DESCRIPTION10 size, 7/8-14 thread, “Delta” series, solenoid operated, 2 way normally closed, spool valve.

OPERATIONWhen de-energized the DE-S2G blocks flow from (1) to (2) and (2) to (1). When energized the valve allows flow from (1) to (2) and (2) to (1).OPERATION OF MANUAL OVERRIDE OPTION: to override, pull knob out. On the detented version, after pulling knob out twist 180 degrees and release. The valve will remain in that position.

FEATURES • Hardened parts for long life.• Efficient wet-armature construction.• Cartridges are voltage interchangeable.• Manual override option.• Industry common cavity.• Unitized, molded coil design.• Continuous duty rated solenoid.• Optional coil voltages and terminations.• Optional “I” Coil: Weatherproof, Thermal Shock, Immersion Safe.

Nominal Flow 8 GPM (30 LPM) from (1) to (2) 5 GPM (19 LPM) from (2) to (1)Rated Operating Pressure 3000 PSI (207 bar)Typical Internal Leakage (150 SSU) 5 cu in/min (82 ml/min)Viscosity Range 36 to 3000 SSU (3 to 647 cSt)Filtration ISO 18/16/13Media Operating Temp. Range -40° to 250°F (-40° to 120°C)Weight .26 lbs (.12 kg)Operating Fluid Media General Purpose Hydraulic FluidCartridge Torque Requirements 30 ft-lbs (40.6 Nm)Coil Nut Torque Requirements 4-6 ft-lbs (5.4-8.1 Nm)Cavity DELTA 2WCavity Tools Kit (form tool, reamer, tap) 40500000Seal Kit 21191202

Actual Test Data (Cartridge Only)

VALVE SPECIFICATIONS

0

50

100

150

0 5 10 15 20Flow (GPM)

Pre

ssur

e D

rop

(PS

I)

0

5

10

0 25 50 75Flow (LPM)

Pre

ssur

e D

rop

(bar

)

Port 1 to 2 (eng) Port 2 to 1 (eng)

Operational shift limit 8 GPM (30 LPM) and 5 GPM (19 LPM). For shifted flow performance consult chart. For higher flow or pressure see HE-S2G.

PERFORMANCE

HYDRAULIC SYMBOL

2

1

Page 53: SOLENOID OPERATED DIRECTIONAL … 1000 38 69 7/8-14 DE-S2F SD18 2 WAY 2 POSITION NORMALLY CLOSED POPPET VALVES SLID PRATD DIRTIAL TRLS Page SD3 Via Malavolti, 36 • 41122 Modena •

SOLENOID OPERATED DIRECTIONAL CONTROLS

Page SD57

Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512 mail: [email protected] • www.tecnord.com

4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 mail: [email protected] • www.delta-power.com

WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken without independent study, evaluation, and testing for suitability.

W 2

0 /

2018

DIMENSIONS

ORDERING INFORMATIONApproximate Coil Weight: .74 lbs (.33 kg)

OPTIONS BODIESBuna Standard 00 Blank Without BodyViton Standard V0 N 3/8 NPTF Ports

Buna, Override, Detent 0M S #8 SAE PortsViton, Override, Detent VM

Buna, Screen A0Viton, Screen W0

Buna, Override, Nondetent B1Buna, Override, Nondetent V1 VOLTAGE

Buna, Screen, Override, Nondetent B3 06 6 VDCViton, Screen, Override, Nondetent V3 12 12 VDC

Buna, Screen, Override, Detent B4 24 24 VDCViton, Screen, Override, Detent V4 36 36 VDC

48 48 VDCNote: use screen only if flow 25 24 VAC

direction is from (1) to (2) 11 120 VAC22 220 VAC

“D” COIL TERMINATION 44 440 VAC(All DC Except as Noted)

IMMERSION PROOF “D” TYPEDL Double Lead SS Single Spade IA “I” Coil AMP Superseal - IntegralDT Deutsch on Leads DT04-2P DS Double Spade ID “I” Coil Deutsch - Integral DT04-2PML Metri-Pack on Leads HC DIN 43650 (Hirschmann) - (AC&DC) IJ “I” Coil AMP Jr. Timer - IntegralPL Packard on Leads CL Conduit Lead - (AC Only) IM “I” Coil Metri-Pack - IntegralWL Weatherpack on Leads DI Deutsch - Integral DT04-2P

DE-S2G – – – –

DE

LTA P

OW

ER

CO

.

2.00 [50.8]

.13 [3.2]

.63 [16.0]

1.75 [44.5]

1.63 [41.4]2.13

[54.1]

.81 [20.6]1.50

[38.1]

.75 [19.1]

BODY WEIGHT: .47 lbs (.21 kg)

.28 [7.1] DIA.MTG. SLOTS2X

#8 SAE PORTS2X

2.28 [58.0]

SOLENOID OPERATED DIRECTIONAL CONTROLS

Page SD57

Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512 mail: [email protected] • www.tecnord.com

4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 mail: [email protected] • www.delta-power.com

WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken without independent study, evaluation, and testing for suitability.

W 1

8 /

2017

DIMENSIONS

ORDERING INFORMATIONApproximate Coil Weight: .74 lbs (.33 kg)

OPTIONS BODIESBuna Standard 00 Blank Without BodyViton Standard V0 N 3/8 NPTF Ports

Buna, Override, Detent 0M S #8 SAE PortsViton, Override, Detent VM

Buna, Screen A0Viton, Screen W0

Buna, Override, Nondetent B1Buna, Override, Nondetent V1 VOLTAGE

Buna, Screen, Override, Nondetent B3 06 6 VDCViton, Screen, Override, Nondetent V3 12 12 VDC

Buna, Screen, Override, Detent B4 24 24 VDCViton, Screen, Override, Detent V4 36 36 VDC

48 48 VDCNote: use screen only if flow 25 24 VAC

direction is from (1) to (2) 11 120 VAC22 220 VAC

“D” COIL TERMINATION 44 440 VAC(All DC Except as Noted)

IMMERSION PROOF “D” TYPEDL Double Lead SS Single Spade IA “I” Coil AMP Superseal - IntegralDT Deutsch on Leads DT04-2P DS Double Spade ID “I” Coil Deutsch - Integral DT04-2PML Metri-Pack on Leads HC DIN 43650 (Hirschmann) - (AC&DC) IJ “I” Coil AMP Jr. Timer - IntegralPL Packard on Leads CL Conduit Lead - (AC Only) IM “I” Coil Metri-Pack - IntegralWL Weatherpack on Leads DI Deutsch - Integral DT04-2P

DE-S2G – – – –

DE

LTA P

OW

ER

CO

.

2.00 [50.8]

.13 [3.2]

.63 [16.0]

1.75 [44.5]

1.63 [41.4]2.13

[54.1]

.81 [20.6]1.50

[38.1]

.75 [19.1]

BODY WEIGHT: .47 lbs (.21 kg)

.28 [7.1] DIA.MTG. SLOTS2X

#8 SAE PORTS2X

2.28 [58.0]

SOLENOID OPERATED DIRECTIONAL CONTROLS Delta Power Company4484 Boeing Drive - Rockford, IL 61109

WARNING: The specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken without independent study, evaluation, and testing for suitability.

Phone: (815) 397-6628 Fax: (815) 397-2526 E-mail: [email protected]

DIMENSIONS

2.35 [59.6]

1.25 [31.7]

.22 [5.6] 7/8-14 UNF 2 A

THREAD

1.00 [25.4] HEX

1.56 [39.6]

1.84 [46.6]

SEE COI L DATAFOR TERMIN ATIONS

DE

LTA POW

ER

CO

.

3.35 [85.0]

.75 [19.1]

HEX NU T

MANUAL OVERRIDE

STANDARD 7/16-20 UNF 2 ATHREAD

.48 [12.2]

ORDERING INFORMATION DE-S2G - - - -

OPTIONS BODIES

Buna Standard 00 Blank Without Body Viton Standard V0 N 3/8 NPTF Ports Buna, Override 0M S #8 SAE Ports Viton, Override VM

Buna, Screen A0 Viton, Screen W0 VOLTAGE

Buna, Override, Non-detent B1 06 6 VDC Viton, Override, Non-detent V1 12 12 VDC

Buna, Screen, Override, Non-detent B3 24 24 VDC Buna, Screen, Override, Detent B4 36 36 VDC

Viton, Screen, Override, Non-detent V3 48 48 VDC Viton, Screen, Override, Detent V4 25 24 VAC

11 120 VAC 22 220 VAC Note: Use screen only if flow direction

is from (1) to (2). 44 440 VAC

“D” COIL TERMINATION (All DC Except as Noted)

IMMERSION PROOF “D” TYPE DL Double Lead SS Single Spade IA “I” Coil AMP Superseal - Integral DT Deutsch on Leads DT04-2P DS Double Spade ID “I” Coil Deutsch – Integral DT04-2P ML Metri-Pack on Leads HC DIN 43650 (Hirschman) – (AC & DC) IJ “I” Coil AMP Jr. Timer - Integral PL Packard on Leads CL Conduit Lead – (AC Only) IM “I” Coil Metri-Pack – Integral WL Weatherpack on Leads DI Deutsch – Integral DT04-2P

Approximate Coil Weight: .74 lbs (.33 kg.)

Page 71

Page 54: SOLENOID OPERATED DIRECTIONAL … 1000 38 69 7/8-14 DE-S2F SD18 2 WAY 2 POSITION NORMALLY CLOSED POPPET VALVES SLID PRATD DIRTIAL TRLS Page SD3 Via Malavolti, 36 • 41122 Modena •

SOLENOID OPERATED DIRECTIONAL CONTROLS

Page SD58

Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512 mail: [email protected] • www.tecnord.com

4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 mail: [email protected] • www.delta-power.com

WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken without independent study, evaluation, and testing for suitability.

W 20 / 2018

HE-S2G DIRECT ACTING SPOOL, 2 WAY NORMALLY CLOSED

DESCRIPTION“High Pressure” 10 size, 7/8-14 thread, “Delta” series, solenoid operated, 2 way normally closed, spool valve.

OPERATIONWhen de-energized the HE-S2G blocks flow from (1) to (2) and (2) to (1). When energized the valve allows flow from (1) to (2) and (2) to (1).

FEATURES • Hardened parts for long life.• Efficient wet-armature construction.• Cartridges are voltage interchangeable.• Industry common cavity.• Unitized, molded coil design.• Continuous duty rated solenoid.• Optional coil voltages and terminations.• Optional “I” Coil: Weatherproof, Thermal Shock, Immersion Safe.

Nominal Flow 15 GPM (57 LPM) from (1) to (2) 6 GPM (23 LPM) from (2) to (1)Rated Operating Pressure 4000 PSI (276 bar)Typical Internal Leakage (150 SSU) 8 cu in/min (131 ml/min)Viscosity Range 36 to 3000 SSU (3 to 647 cSt)Filtration ISO 18/16/13Media Operating Temp. Range -40° to 250°F (-40° to 120°C)Weight .39 lbs (.17 kg)Operating Fluid Media General Purpose Hydraulic FluidCartridge Torque Requirements 35 ft-lbs (47.5 Nm)Coil Nut Torque Requirements 4-6 ft-lbs (5.4-8.1 Nm)Cavity DELTA 2WCavity Tools Kit (form tool, reamer, tap) 40500000Seal Kit 21191202

Actual Test Data (Cartridge Only)

VALVE SPECIFICATIONS

0

50

100

150

200

250

0 5 10 15 20Flow (GPM)

Pre

ssur

e D

rop

(PS

I)

0

5

10

15

0 25 50 75Flow (LPM)

Pre

ssur

e D

rop

(bar

)

Port 1 to 2 (eng) Port 2 to 1 (eng)

Uses “L” Coils.

PERFORMANCE

HYDRAULIC SYMBOL

2

1

Page 55: SOLENOID OPERATED DIRECTIONAL … 1000 38 69 7/8-14 DE-S2F SD18 2 WAY 2 POSITION NORMALLY CLOSED POPPET VALVES SLID PRATD DIRTIAL TRLS Page SD3 Via Malavolti, 36 • 41122 Modena •

SOLENOID OPERATED DIRECTIONAL CONTROLS

Page SD59

Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512 mail: [email protected] • www.tecnord.com

4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 mail: [email protected] • www.delta-power.com

WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken without independent study, evaluation, and testing for suitability.

W 2

0 /

2018

Note: Aluminum, NOT durability rated for 4000 PSI. Consult factory for body options.

DIMENSIONS

ORDERING INFORMATIONApproximate Coil Weight: .68 lbs (.31 kg)

OPTIONS BODIESBuna Standard 00 Blank Without BodyViton Standard V0 N 3/8 NPTF Ports

S #8 SAE Ports

VOLTAGE06 6 VDC12 12 VDC24 24 VDC36 36 VDC48 48 VDC25 25 VAC11 120 VAC22 220 VAC

“L” COIL TERMINATION 44 440 VAC(All DC Except as Noted)

IMMERSION PROOF “L” TYPEDL Double Lead SS Single Spade IA “I” Coil AMP Superseal - IntegralDT Deutsch on Leads DT04-2P DS Double Spade ID “I” Coil Deutsch - Integral DT04-2PML Metri-Pack on Leads HC DIN 43650 (Hirschmann) - (AC&DC) IJ “I” Coil AMP Jr. Timer - IntegralPL Packard on Leads CL Conduit Lead - (AC Only) IM “I” Coil Metri-Pack - IntegralWL Weatherpack on Leads DI Deutsch - Integral DT04-2P

HE-S2G – – – – D

ELTA

PO

WE

R

1.83

[46.6]

.75 [19.1]

HEX NUT

1.25 [31.7]

2.66 [67.5]

3.91 [99.2]

.50 [12.7]

1.00 [25.4] HEX

7/8-14 UNF-2A THREAD

1.56 [39.6]

SEE COIL DATAFOR TERMINATIONS

DE

LTA P

OW

ER

1.59 [40.4]

#8 SAE PORTS2X

.281 [7.1] DIA. MTG. HOLES2X

BODY WEIGHT: .47 lbs (.21 kg)

1.50 [38.1]

.81 [20.6]

2.63 [66.7]

.47 [11.9]

.63 [16.0]

1.63 [41.4]2.13

[54.1]

.13 [3.2]

.75 [19.1] 1.75

[44.5]2.00

[50.8]

Page 56: SOLENOID OPERATED DIRECTIONAL … 1000 38 69 7/8-14 DE-S2F SD18 2 WAY 2 POSITION NORMALLY CLOSED POPPET VALVES SLID PRATD DIRTIAL TRLS Page SD3 Via Malavolti, 36 • 41122 Modena •

SOLENOID OPERATED DIRECTIONAL CONTROLS

Page SD60

W 20 / 2018

Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512 mail: [email protected] • www.tecnord.com

4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 mail: [email protected] • www.delta-power.com

WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken without independent study, evaluation, and testing for suitability.

2W2P NORMALLY OPEN GPM PSI LPM BAR CAVITY MODEL PAGE

10 3500 38 241 3/4-16 PB-S2C SD62

12 5000 45 345 3/4-16 HB-S2C SD64

15 3500 57 241 7/8-14 DE-S2C SD68

30 3000 114 207 1 1/16-12 TT-S2C SD70

40 3000 151 207 1 5/16-12 SJ-S2C SD72

40 4350 151 300 1 5/16-12 HJ-S2C SD74

10 3500 38 241 3/4-16 PB-S2D SD76

12 5000 45 345 3/4-16 HB-S2D SD78

15 3500 57 241 7/8-14 DE-S2D SD80

30 3000 114 207 1 1/16-12 TT-S2D SD82

40 3000 151 207 1 5/16-12 SJ-S2D SD84

8 2000 30 138 3/4-16 PB-S2J SD66

2W2P NORMALLY OPEN GPM PSI LPM BAR CAVITY MODEL PAGE

12 5000 45 345 3/4-16 HB-S2K SD86

2 WAY 2 POSITION NORMALLY OPEN POPPET VALVES

2 WAY 2 POSITION NORMALLY OPEN BIDIRECTIONAL POPPET VALVES

Page 57: SOLENOID OPERATED DIRECTIONAL … 1000 38 69 7/8-14 DE-S2F SD18 2 WAY 2 POSITION NORMALLY CLOSED POPPET VALVES SLID PRATD DIRTIAL TRLS Page SD3 Via Malavolti, 36 • 41122 Modena •

SOLENOID OPERATED DIRECTIONAL CONTROLS

Page SD61

W 2

0 /

2018

Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512 mail: [email protected] • www.tecnord.com

4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 mail: [email protected] • www.delta-power.com

WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken without independent study, evaluation, and testing for suitability.

Typical application for the S2C is a pump unloading circuit when high flow and low pressure drop is required.Typical application for the S2D is for when free flow is required in both directions to float the cylinder.Typical application for the S2J is for low pressure applications where the soft seat gives better leakage control.

TYPICAL SCHEMATIC

SOLENOID OPERATED DIRECTIONAL CONTROLS

Page 58: SOLENOID OPERATED DIRECTIONAL … 1000 38 69 7/8-14 DE-S2F SD18 2 WAY 2 POSITION NORMALLY CLOSED POPPET VALVES SLID PRATD DIRTIAL TRLS Page SD3 Via Malavolti, 36 • 41122 Modena •

SOLENOID OPERATED DIRECTIONAL CONTROLS

Page SD62

Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512 mail: [email protected] • www.tecnord.com

4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 mail: [email protected] • www.delta-power.com

WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken without independent study, evaluation, and testing for suitability.

W 20 / 2018

PB-S2C PILOT OPERATED POPPET, 2 WAY NORMALLY OPEN

DESCRIPTION8 size, 3/4-16 thread, “Power” series, solenoid operated, 2 way normally open, pilot operated poppet valve with free reverse flow energized.

OPERATIONWhen de-energized the PB-S2C allows flow from (1) to (2) and restricted flow from (2) to (1). When energized the valve blocks flow from (1) to (2) and allows flow from (2) to (1).OPERATION OF MANUAL OVERRIDE OPTION: to override, turn the manual override screw clockwise.To release turn the manual override screw counterclockwise.

FEATURES • Hardened parts for long life.• Efficient wet-armature construction.• Cartridges are voltage interchangeable.• Manual override option.• Industry common cavity.• Unitized, molded coil design.• Continuous duty rated solenoid.• Optional coil voltages and terminations.• Optional “I” Coil: Weatherproof, Thermal Shock, Immersion Safe.

Nominal Flow 10 GPM (38 LPM)Rated Operating Pressure 3500 PSI (241 bar)Typical Internal Leakage (150 SSU) 0-5 drops/minViscosity Range 36 to 3000 SSU (3 to 647 cSt)Filtration ISO 18/16/13Media Operating Temp. Range -40° to 250°F (-40° to 120°C)Weight .22 lbs (.10 kg)Operating Fluid Media General Purpose Hydraulic FluidCartridge Torque Requirements 25 ft-lbs (34 Nm)Coil Nut Torque Requirements 4-6 ft-lbs (5.4-8.1 Nm)Cavity POWER 2WCavity Tools Kit (form tool, reamer, tap) 40500005Seal Kit 21191100

Actual Test Data (Cartridge Only)

VALVE SPECIFICATIONS

0

50

100

150

200

250

0 62 4 8 10 120

Flow (GPM)

5

Pre

ssur

e D

rop

(PS

I)

10

15

0 10 3020 40

Pre

ssur

e D

rop

(bar

)

Flow (LPM)

Port 1 to 2 (de-eng) Port 2 to 1 (eng)

Unshifted limit 10 GPM (38 LPM) from (1) to (2) when deenergized. For shifted flow performance consult chart.

PERFORMANCE

HYDRAULIC SYMBOL

2

1

Page 59: SOLENOID OPERATED DIRECTIONAL … 1000 38 69 7/8-14 DE-S2F SD18 2 WAY 2 POSITION NORMALLY CLOSED POPPET VALVES SLID PRATD DIRTIAL TRLS Page SD3 Via Malavolti, 36 • 41122 Modena •

SOLENOID OPERATED DIRECTIONAL CONTROLS

Page SD63

Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512 mail: [email protected] • www.tecnord.com

4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 mail: [email protected] • www.delta-power.com

WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken without independent study, evaluation, and testing for suitability.

W 2

0 /

2018

DIMENSIONS

ORDERING INFORMATIONApproximate Coil Weight: .42 lbs (.19 kg)

OPTIONS BODIESBuna Standard 00 Blank Without BodyViton Standard V0 N 1/4 NPTF Ports

Buna, Override, Detent 0M S #6 SAE PortsViton, Override, Detent VMBuna, Override, Knob 0KViton, Override, Knob VK

Buna, Screen A0Viton, Screen W0 VOLTAGE

Buna, Screen, Override B2 06 6 VDCViton, Screen, Override V2 12 12 VDC

Buna, Screen, Override, Knob B5 24 24 VDCViton, Screen, Override, Knob V5 36 36 VDC

48 48 VDCNote: use screen only if flow 25 24 VAC

direction is from (1) to (2) 11 120 VAC22 220 VAC

“P” COIL TERMINATION 44 440 VAC(All DC Except as Noted)

IMMERSION PROOF “P” TYPEDL Double Lead SS Single Spade IA “I” Coil AMP Superseal - IntegralDT Deutsch on Leads DT04-2P DS Double Spade ID “I” Coil Deutsch - Integral DT04-2PML Metri-Pack on Leads HC DIN 43650 (Hirschmann) - (AC&DC) IJ “I” Coil AMP Jr. Timer - IntegralPL Packard on Leads CL Conduit Lead - (AC Only) IM “I” Coil Metri-Pack - IntegralWL Weatherpack on Leads DI Deutsch - Integral DT04-2P

PB-S2C – – – –

1.25 [31.7]

1.54 [39.1]

.75 [19.0]

HEX NUT

DE

LTA P

OW

ER

CO

.

SEE COIL DATAFOR TERMINATIONS

.25 [6.3]

1.09 [27.8]

2.53 [64.3]

2.88 [73.2]

.87 [22.1] HEX

3/4-16 UNF-2ATHREAD

#12-24 UNC-2A THREAD

MANUAL OVERRIDE

STANDARD

3.16 [80.3]

OVERRIDE W/KNOB

2.00 [50.8]

#6 SAE PORT2X

2.00 [50.8]

1.50 [38.1]

.25 [6.4]

.25 [6.4]

1.52 [38.5]

.28 [7.1] DIA.MTG. HOLES2X

1.75 [44.5]

.50 [12.7]

DE

LTA P

OW

ER

CO

.

BODY WEIGHT: .39 lbs (.18 kg)

1.13 [28.6]

.63 [15.9]

1.25 [31.8]

2.50 [63.4]

Page 60: SOLENOID OPERATED DIRECTIONAL … 1000 38 69 7/8-14 DE-S2F SD18 2 WAY 2 POSITION NORMALLY CLOSED POPPET VALVES SLID PRATD DIRTIAL TRLS Page SD3 Via Malavolti, 36 • 41122 Modena •

SOLENOID OPERATED DIRECTIONAL CONTROLS

Page SD64

Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512 mail: [email protected] • www.tecnord.com

4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 mail: [email protected] • www.delta-power.com

WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken without independent study, evaluation, and testing for suitability.

W 20 / 2018

HB-S2C PILOT OPERATED POPPET, 2 WAY NORMALLY OPEN

DESCRIPTION8 size, 3/4-16 thread, “Power” series, solenoid operated, 2 way normally open, pilot operated poppet valve with reverse flow energized.

OPERATIONWhen de-energized the HB-S2C allows flow from (1) to (2) and restricted flow from (2) to (1). When energized the valve blocks flow from (1) to (2) and allows flow from (2) to (1).MANUAL OVERRIDE OPTION: to override, turn the manual override screw clockwise. To release, turn the manual override screw counter-clockwise.

FEATURES • Hardened parts for long life.• Efficient wet-armature construction.• Cartridges are voltage interchangeable.• Manual override option.• Industry common cavity.• Unitized, molded coil design.• Continuous duty rated solenoid.• Optional coil voltages and terminations.• Optional “I” Coil: Weatherproof, Thermal Shock, Immersion Safe.

Nominal Flow 12 GPM (45 LPM)Rated Operating Pressure 5000 PSI (345 bar)Typical Internal Leakage 0-5 drops/min at 5000 PSI(150 SSU) (345 bar)Viscosity Range 36 to 3000 SSU (3 to 647 cSt)Filtration ISO 18/16/13Media Operating Temp. Range -40° to 210°F (-40° to 100°C) BUNA seals -4° to 250°F (-20° to 120°C) VITON sealsWeight .29 lbs (.13 kg)Operating Fluid Media General Purpose Hydraulic FluidCartridge Torque Requirements 35 ft-lbs (47 Nm)Coil Nut Torque Requirements 4-6 ft-lbs (5.4-8.1 Nm)Cavity POWER 2WCavity Tools Kit 40500005Seal Kit 21191100

Actual Test Data (Cartridge Only)

VALVE SPECIFICATIONS

Flow (GPM)

Pre

ssur

e D

rop

(PS

I)

Pre

ssur

e D

rop

(bar

)

Flow (LPM)

PERFORMANCE

HYDRAULIC SYMBOL

TECNORDSERVOCOMANDI E REGOLAZIONE

Page 61: SOLENOID OPERATED DIRECTIONAL … 1000 38 69 7/8-14 DE-S2F SD18 2 WAY 2 POSITION NORMALLY CLOSED POPPET VALVES SLID PRATD DIRTIAL TRLS Page SD3 Via Malavolti, 36 • 41122 Modena •

SOLENOID OPERATED DIRECTIONAL CONTROLS

Page SD65

Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512 mail: [email protected] • www.tecnord.com

4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 mail: [email protected] • www.delta-power.com

WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken without independent study, evaluation, and testing for suitability.

W 2

0 /

2018

DIMENSIONS

ORDERING INFORMATIONApproximate Coil Weight: .42 lbs (.19 kg)

TECNORDSERVOCOMANDI E REGOLAZIONE

TECNORDSERVOCOMANDI E REGOLAZIONE

“P” COIL IMMERSION PROOF “I” COIL

OPTIONS BODIESBuna Standard 00 Blank Without BodyViton Standard V0 N 1/4 NPTF Ports

Buna, Override, Knob 0K S #6 SAE PortsViton, Override, Knob VK

Buna, Screen A0 VOLTAGEViton, Screen W0 06 6 VDC

Buna, Screen, Override, Knob B5 12 12 VDCViton, Screen, Override, Knob V5 24 24 VDC

36 36 VDC48 48 VDC

Note: use screen only if flow 25 24 VACdirection is from (1) to (2) 11 120 VAC

22 220 VAC44 440 VAC

“P” COIL TERMINATION IMMERSION PROOF “I” COIL TERMINATION

DL Double Lead SS Single Spade IA “I” Coil AMP Superseal - IntegralDT Deutsch on Leads DT04-2P DS Double Spade ID “I” Coil Deutsch - Integral DT04-2PML Metri-Pack on Leads HC DIN 43650 (Hirschmann) - (AC&DC) IJ “I” Coil AMP Jr. Timer - IntegralPL Packard on Leads CL Conduit Lead - (AC Only) IM “I” Coil Metri-Pack - IntegralWL Weatherpack on Leads DI Deutsch - Integral DT04-2P

For Optional Coil Terminations See Coil Section

HB-S2C – – – –

Note: Aluminum Body Not durability rated for 5000 PSI (345 bar), consult factory for high pressure body options.

Page 62: SOLENOID OPERATED DIRECTIONAL … 1000 38 69 7/8-14 DE-S2F SD18 2 WAY 2 POSITION NORMALLY CLOSED POPPET VALVES SLID PRATD DIRTIAL TRLS Page SD3 Via Malavolti, 36 • 41122 Modena •

SOLENOID OPERATED DIRECTIONAL CONTROLS

Page SD66

Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512 mail: [email protected] • www.tecnord.com

4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 mail: [email protected] • www.delta-power.com

WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken without independent study, evaluation, and testing for suitability.

W 20 / 2018

PB-S2J PILOT OPERATED POPPET, 2 WAY NORMALLY OPEN, SOFT SEAT

DESCRIPTION8 size, 3/4-16 thread, “Power” series, solenoid operated, 2 way normally open, pilot operated soft seat poppet valve with free reverse flow energized.

OPERATIONWhen de-energized the PB-S2J allows flow from (1) to (2) and restricts flow from (2) to (1). When energized the valve blocks flow from (1) to (2) and allows free flow from (2) to (1).OPERATION OF MANUAL OVERRIDE OPTION: to override, turn the manual override screw clockwise.To release turn the manual override screw counterclockwise.

FEATURES • Soft seat for ultra low leakage.• Efficient wet-armature construction.• Cartridges are voltage interchangeable.• Manual override option.• Industry common cavity.• Unitized, molded coil design.• Continuous duty rated solenoid.• Optional coil voltages and terminations.• Optional “I” Coil: Weatherproof, Thermal Shock, Immersion Safe.

Nominal Flow 8 GPM (30 LPM)Rated Operating Pressure 2000 PSI (138 bar)Typical Internal Leakage (150 SSU) NegligibleViscosity Range 36 to 3000 SSU (3 to 647 cSt)Filtration ISO 18/16/13Media Operating Temp. Range -35° to 200°F (-37° to 93°C)Weight .21 lbs (.10 kg)Operating Fluid Media General Purpose Hydraulic FluidCartridge Torque Requirements 25 ft-lbs (34 Nm)Coil Nut Torque Requirements 4-6 ft-lbs (5.4-8.1 Nm)Cavity POWER 2WCavity Tools Kit (form tool, reamer, tap) 40500005Seal Kit 21191100

Actual Test Data (Cartridge Only)

VALVE SPECIFICATIONS

0

50

100

150

200

250

300

350

0 42 86 100

Pre

ssur

e D

rop

(PS

I)

5

10

15

Flow (GPM)

20

0 5 10 2015 25 3530

Pre

ssur

e D

rop

(bar

)

Flow (LPM)

Port 1 to 2 (de-eng) Port 2 to 1 (eng)

Unshifted limit 6 GPM (23 LPM) from (1) to (2) energized. For shifted flow performance consult chart.

PERFORMANCE

HYDRAULIC SYMBOL

2

1

Page 63: SOLENOID OPERATED DIRECTIONAL … 1000 38 69 7/8-14 DE-S2F SD18 2 WAY 2 POSITION NORMALLY CLOSED POPPET VALVES SLID PRATD DIRTIAL TRLS Page SD3 Via Malavolti, 36 • 41122 Modena •

SOLENOID OPERATED DIRECTIONAL CONTROLS

Page SD67

Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512 mail: [email protected] • www.tecnord.com

4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 mail: [email protected] • www.delta-power.com

WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken without independent study, evaluation, and testing for suitability.

W 2

0 /

2018

DIMENSIONS

ORDERING INFORMATIONApproximate Coil Weight: .42 lbs (.19 kg)

OPTIONS BODIESBuna Standard 00 Blank Without BodyViton Standard V0 N 1/4 NPTF Ports

Buna, Override, Detent 0M S #6 SAE PortsViton, Override, Detent VM

Buna, Screen A0Viton, Screen W0

Buna, Screen Override B2Viton, Screen, Override V2 VOLTAGE

06 6 VDC12 12 VDC

Note: use screen only if flow 24 24 VDCdirection is from (1) to (2) 36 36 VDC

48 48 VDC25 24 VAC11 120 VAC22 220 VAC

“P” COIL TERMINATION 44 440 VAC(All DC Except as Noted)

IMMERSION PROOF “P” TYPEDL Double Lead SS Single Spade IA “I” Coil AMP Superseal - IntegralDT Deutsch on Leads DT04-2P DS Double Spade ID “I” Coil Deutsch - Integral DT04-2PML Metri-Pack on Leads HC DIN 43650 (Hirschmann) - (AC&DC) IJ “I” Coil AMP Jr. Timer - IntegralPL Packard on Leads CL Conduit Lead - (AC Only) IM “I” Coil Metri-Pack - IntegralWL Weatherpack on Leads DI Deutsch - Integral DT04-2P

PB-S2J – – – – Approximate Coil Weight: .42 lbs (.19 kg)

1.25 [31.7]

1.54 [39.1]

.75 [19.0]

HEX NUT

DE

LTA P

OW

ER

CO

.

SEE COIL DATAFOR TERMINATIONS

.25 [6.3]

1.09 [27.8]

2.53 [64.3]

2.88 [73.2]

.87 [22.1] HEX

3/4-16 UNF-2ATHREAD

#12-24 UNC-2A THREAD

MANUAL OVERRIDE

STANDARD

3.16 [80.3]

OVERRIDE W/KNOB

2.00 [50.8]

#6 SAE PORT2X

2.00 [50.8]

1.50 [38.1]

.25 [6.4]

.25 [6.4]

1.52 [38.5]

.28 [7.1] DIA.MTG. HOLES2X

1.75 [44.5]

.50 [12.7]

DE

LTA P

OW

ER

CO

.

BODY WEIGHT: .39 lbs (.18 kg)

1.13 [28.6]

.63 [15.9]

1.25 [31.8]

2.50 [63.4]

Page 64: SOLENOID OPERATED DIRECTIONAL … 1000 38 69 7/8-14 DE-S2F SD18 2 WAY 2 POSITION NORMALLY CLOSED POPPET VALVES SLID PRATD DIRTIAL TRLS Page SD3 Via Malavolti, 36 • 41122 Modena •

SOLENOID OPERATED DIRECTIONAL CONTROLS

Page SD68

Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512 mail: [email protected] • www.tecnord.com

4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 mail: [email protected] • www.delta-power.com

WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken without independent study, evaluation, and testing for suitability.

W 20 / 2018

DE-S2C PILOT OPERATED POPPET, 2 WAY NORMALLY OPEN

DESCRIPTION10 size, 7/8-14 thread, “Delta” series, solenoid operated, 2 way normally open, pilot operated poppet valve with free reverse flow energized.

OPERATIONWhen de-energized the DE-S2C allows flow to pass from (1) to (2), but restricts flow from (2) to (1). When energized the valve blocks flow from (1) to (2) but allows free reverse flow from (2) to (1).OPERATION OF MANUAL OVERRIDE OPTION: to override, turn the manual override screw clockwise.To release turn the manual override screw counterclockwise.

FEATURES • Hardened parts for long life.• Efficient wet-armature construction.• Cartridges are voltage interchangeable.• Manual override option.• Industry common cavity.• Unitized, molded coil design.• Continuous duty rated solenoid.• Optional coil voltages and terminations.• Optional “I” Coil: Weatherproof, Thermal Shock, Immersion Safe.

Nominal Flow 15 GPM (57 LPM)Rated Operating Pressure 3500 PSI (241 bar)Typical Internal Leakage (150 SSU) 0-5 drops/minViscosity Range 36 to 3000 SSU (3 to 647 cSt)Filtration ISO 18/16/13Media Operating Temp. Range -40° to 250°F (-40° to 120°C)Weight .29 lbs (.13 kg)Operating Fluid Media General Purpose Hydraulic FluidCartridge Torque Requirements 30 ft-lbs (40.6 Nm)Coil Nut Torque Requirements 4-6 ft-lbs (5.4-8.1 Nm)Cavity DELTA 2WCavity Tools Kit (form tool, reamer, tap) 40500000Seal Kit 21191200

Actual Test Data (Cartridge Only)

VALVE SPECIFICATIONS

0

50

100

150

200

0 5 1510 20

Flow (GPM)

0

5

0

10

Pre

ssur

e D

rop

(PS

I)

25 50 75Flow (LPM)

Pre

ssur

e D

rop

(bar

)

Port 1 to 2 (de-eng) Port 2 to 1 (eng)

PERFORMANCE

HYDRAULIC SYMBOL

2

1

Page 65: SOLENOID OPERATED DIRECTIONAL … 1000 38 69 7/8-14 DE-S2F SD18 2 WAY 2 POSITION NORMALLY CLOSED POPPET VALVES SLID PRATD DIRTIAL TRLS Page SD3 Via Malavolti, 36 • 41122 Modena •

SOLENOID OPERATED DIRECTIONAL CONTROLS

Page SD69

Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512 mail: [email protected] • www.tecnord.com

4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 mail: [email protected] • www.delta-power.com

WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken without independent study, evaluation, and testing for suitability.

W 2

0 /

2018

DIMENSIONS

ORDERING INFORMATIONApproximate Coil Weight: .74 lbs (.33 kg)

OPTIONS BODIESBuna Standard 00 Blank Without BodyViton Standard V0 N 3/8 NPTF Ports

Buna, Override, Detent 0M S #8 SAE PortsViton, Override, Detent VMBuna, Override, Knob 0KViton, Override, Knob VK

Buna, Screen A0Viton, Screen W0 VOLTAGE

Buna, Screen, Override B2 06 6 VDCViton, Screen, Override V2 12 12 VDC

Buna, Screen, Override, Knob B5 24 24 VDCViton, Screen, Override, Knob V5 36 36 VDC

48 48 VDCNote: use screen only if flow 25 24 VAC

direction is from (1) to (2) 11 120 VAC22 220 VAC

“D” COIL TERMINATION 44 440 VAC(All DC Except as Noted)

IMMERSION PROOF “D” TYPEDL Double Lead SS Single Spade IA “I” Coil AMP Superseal - IntegralDT Deutsch on Leads DT04-2P DS Double Spade ID “I” Coil Deutsch - Integral DT04-2PML Metri-Pack on Leads HC DIN 43650 (Hirschmann) - (AC&DC) IJ “I” Coil AMP Jr. Timer - IntegralPL Packard on Leads CL Conduit Lead - (AC Only) IM “I” Coil Metri-Pack - IntegralWL Weatherpack on Leads DI Deutsch - Integral DT04-2P

DE-S2C – – – –D

ELTA

PO

WE

R C

O.

.22 [5.6]

2.74 [69.6]

1.25 [31.7]

3.12[79.2]

1.56 [39.6]

SEE COIL DATAFOR TERMINATIONS1.84

[46.6]

#12-24 UNC2A THREAD

MANUAL OVERRIDE W / KNOB

3.39 [86.0]

7/8-14 UNF-2ATHREAD

.75 [19.1]

HEX NUT

1.00 [25.4] HEX

MANUAL OVERRIDE

STANDARD

DE

LTA P

OW

ER

CO

.

2.00 [50.8]

.13 [3.2]

.63 [16.0]

1.75 [44.5]

1.63 [41.4]2.13

[54.1]

2.69 [68.3]

.81 [20.6]1.50

[38.1] 1.59 [40.4]

BODY WEIGHT: .47 lbs (.21 kg)

.28 [7.1] DIA.MTG. SLOTS2X

#8 SAE PORTS2X

.75 [19.1]

Page 66: SOLENOID OPERATED DIRECTIONAL … 1000 38 69 7/8-14 DE-S2F SD18 2 WAY 2 POSITION NORMALLY CLOSED POPPET VALVES SLID PRATD DIRTIAL TRLS Page SD3 Via Malavolti, 36 • 41122 Modena •

SOLENOID OPERATED DIRECTIONAL CONTROLS

Page SD70

Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512 mail: [email protected] • www.tecnord.com

4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 mail: [email protected] • www.delta-power.com

WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken without independent study, evaluation, and testing for suitability.

W 20 / 2018

TT-S2C PILOT OPERATED POPPET, 2 WAY NORMALLY OPEN

DESCRIPTION12 size, 1 1/16-12 thread, “Tecnord” series, solenoid operated, 2 way normally open, pilot operated poppet valve with free reverse flow energized.

OPERATIONWhen de-energized the TT-S2C allows flow to pass from (1) to (2), but restricts flow from (2) to (1). When energized the valve blocks flow from (1) to (2) but allows free reverse flow from (2) to (1).OPERATION OF MANUAL OVERRIDE OPTION: to override, turn the manual override screw clockwise.To release turn the manual override screw counterclockwise.

FEATURES • Hardened parts for long life.• Efficient wet-armature construction.• Cartridges are voltage interchangeable.• Manual override option.• Industry common cavity.• Unitized, molded coil design.• Continuous duty rated solenoid.• Optional coil voltages and terminations.• Optional “I” Coil: Weatherproof, Thermal Shock, Immersion Safe.

Nominal Flow 30 GPM (114 LPM)Rated Operating Pressure 3000 PSI (207 bar)Typical Internal Leakage (150 SSU) 0-10 drops/minViscosity Range 36 to 3000 SSU (3 to 647 cSt)Filtration ISO 18/16/13Media Operating Temp. Range -40° to 250°F (-40° to 120°C)Weight .51 lbs (.23 kg)Operating Fluid Media General Purpose Hydraulic FluidCartridge Torque Requirements 70 ft-lbs (94.9 Nm)Coil Nut Torque Requirements 4-6 ft-lbs (5.4-8.1 Nm)Cavity TECNORD 2WCavity Tools Kit (form tool, reamer, tap) 40500032Seal Kit 21191300

Actual Test Data (Cartridge Only)

VALVE SPECIFICATIONS

0

50

100

150

200

0 5 10 2015 25 30 35 40

Flow (GPM)

0

5

10

0

Pre

ssur

e D

rop

(PS

I)

5025 75 100 150125Flow (LPM)

Pre

ssur

e D

rop

(bar

)

Port 1 to 2 (de-eng) Port 2 to 1 (eng)

PERFORMANCE

HYDRAULIC SYMBOL

2

1

Page 67: SOLENOID OPERATED DIRECTIONAL … 1000 38 69 7/8-14 DE-S2F SD18 2 WAY 2 POSITION NORMALLY CLOSED POPPET VALVES SLID PRATD DIRTIAL TRLS Page SD3 Via Malavolti, 36 • 41122 Modena •

SOLENOID OPERATED DIRECTIONAL CONTROLS

Page SD71

Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512 mail: [email protected] • www.tecnord.com

4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 mail: [email protected] • www.delta-power.com

WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken without independent study, evaluation, and testing for suitability.

W 2

0 /

2018

DIMENSIONS

ORDERING INFORMATIONApproximate Coil Weight: .74 lbs (.33 kg)

OPTIONS BODIESBuna Standard 00 Blank Without BodyViton Standard V0 S #12 SAE Ports

Buna, Override, Knob 0KViton, Override, Knob VK

Buna, Screen A0Viton, Screen W0

Buna, Screen, Override, Knob B5Viton, Screen, Override, Knob V5 VOLTAGE

06 6 VDC12 12 VDC24 24 VDC

Note: use screen only if flow 36 36 VDCdirection is from (1) to (2) 48 48 VDC

25 24 VAC11 120 VAC22 220 VAC

“D” COIL TERMINATION 44 440 VAC(All DC Except as Noted)

IMMERSION PROOF “D” TYPEDL Double Lead SS Single Spade IA “I” Coil AMP Superseal - IntegralDT Deutsch on Leads DT04-2P DS Double Spade ID “I” Coil Deutsch - Integral DT04-2PML Metri-Pack on Leads HC DIN 43650 (Hirschmann) - (AC&DC) IJ “I” Coil AMP Jr. Timer - IntegralPL Packard on Leads CL Conduit Lead - (AC Only) IM “I” Coil Metri-Pack - IntegralWL Weatherpack on Leads DI Deutsch - Integral DT04-2P

TT-S2C – – – –D

ELTA

PO

WE

R C

O.

STANDARD

1 1/16-12 UN-2ATHREAD

1.25 [31.7] HEX

SEE COIL DATAFOR TERMINATIONS

1.83 [46.6]

.75 [19.0]

HEX NUT

1.56 [39.6]

1.90 [48.2]

3.00 [76.2]

3.50 [88.8]

.36 [9.2]

MANUAL OVERRIDE

DE

LTA P

OW

ER

CO

.

#12 SAE PORTS2X

.41 [10.3] DIA.MTG. HOLES2X

BODY WEIGHT: 3.71 lbs (1.68 kg)

.88 [22.4]

1.81 [46.0]

1.06 [27.0]

2.87 [72.9]

3.09 [78.5]

1.03 [26.2]

2.25 [57.2]

2.69 [68.4]

.17 [4.3]

2.20 [55.9]

Page 68: SOLENOID OPERATED DIRECTIONAL … 1000 38 69 7/8-14 DE-S2F SD18 2 WAY 2 POSITION NORMALLY CLOSED POPPET VALVES SLID PRATD DIRTIAL TRLS Page SD3 Via Malavolti, 36 • 41122 Modena •

SOLENOID OPERATED DIRECTIONAL CONTROLS

Page SD72

Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512 mail: [email protected] • www.tecnord.com

4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 mail: [email protected] • www.delta-power.com

WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken without independent study, evaluation, and testing for suitability.

W 20 / 2018

SJ-S2C PILOT OPERATED POPPET, 2 WAY NORMALLY OPEN

DESCRIPTION16 size, 1 5/16-12 thread, “Super” series, solenoid operated, 2 way normally open, pilot operated poppet valve with free reverse flow energized.

OPERATIONWhen de-energized the SJ-S2C allows flow to pass from (1) to (2), but restricts flow from (2) to (1).When energized the valve blocks flow from (1) to (2) but allows free reverse flow from (2) to (1).

FEATURES • Hardened parts for long life.• Efficient wet-armature construction.• Cartridges are voltage interchangeable.• Industry common cavity.• Unitized, molded coil design.• Continuous duty rated solenoid.• Optional coil voltages and terminations.• Optional “I” Coil: Weatherproof, Thermal Shock, Immersion Safe.

Nominal Flow 40 GPM (151 LPM)Rated Operating Pressure 3000 PSI (207 bar)Typical Internal Leakage (150 SSU) 0-10 drops/minViscosity Range 36 to 3000 SSU (3 to 647 cSt)Filtration ISO 18/16/13Media Operating Temp. Range -40° to 250°F (-40° to 120°C)Weight .74 lbs (.33 kg)Operating Fluid Media General Purpose Hydraulic FluidCartridge Torque Requirements 90 ft-lbs (122 Nm)Coil Nut Torque Requirements 4-6 ft-lbs (5.4-8.1 Nm)Cavity SUPER 2WCavity Tools Kit (form tool, reamer, tap) 40500017Seal Kit 21191400

Actual Test Data (Cartridge Only)

VALVE SPECIFICATIONS

0

50

100

150

0 5 10 15 20 25 30 35 40

Flow (GPM)

0

5

10

0

Pre

ssur

e D

rop

(PS

I)

5025 75 100 150125Flow (LPM)

Pre

ssur

e D

rop

(bar

)

Port 1 to 2 (de-eng) Port 2 to 1 (eng)

PERFORMANCE

HYDRAULIC SYMBOL

2

1

Page 69: SOLENOID OPERATED DIRECTIONAL … 1000 38 69 7/8-14 DE-S2F SD18 2 WAY 2 POSITION NORMALLY CLOSED POPPET VALVES SLID PRATD DIRTIAL TRLS Page SD3 Via Malavolti, 36 • 41122 Modena •

SOLENOID OPERATED DIRECTIONAL CONTROLS

Page SD73

Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512 mail: [email protected] • www.tecnord.com

4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 mail: [email protected] • www.delta-power.com

WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken without independent study, evaluation, and testing for suitability.

W 2

0 /

2018

DIMENSIONS

ORDERING INFORMATIONApproximate Coil Weight: .74 lbs (.33 kg)

OPTIONS BODIESBuna Standard 00 Blank Without BodyViton Standard V0 N 3/4 NPTF PortsBuna, Screen A0 S #12 SAE PortsViton, Screen W0

Buna, Override, Knob 0KViton, Override, Knob VK

Buna, Screen, Override B2Viton, Screen, Override V2 VOLTAGE

06 6 VDC12 12 VDC24 24 VDC

Note: use screen only if flow 36 36 VDCdirection is from (1) to (2) 48 48 VDC

25 24 VAC11 120 VAC22 220 VAC

“D” COIL TERMINATION 44 440 VAC(All DC Except as Noted)

IMMERSION PROOF “D” TYPEDL Double Lead SS Single Spade IA “I” Coil AMP Superseal - IntegralDT Deutsch on Leads DT04-2P DS Double Spade ID “I” Coil Deutsch - Integral DT04-2PML Metri-Pack on Leads HC DIN 43650 (Hirschmann) - (AC&DC) IJ “I” Coil AMP Jr. Timer - IntegralPL Packard on Leads CL Conduit Lead - (AC Only) IM “I” Coil Metri-Pack - IntegralWL Weatherpack on Leads DI Deutsch - Integral DT04-2P

SJ-S2C – – – –D

ELTA

PO

WE

R C

O.

2.93 [74.5]

1.80 [45.8]

.41 [10.5]

1.56 [39.6]

1.85 [47.1].75

[19.1]HEX NUT

1.63 [41.3] HEX

1 5/16-12 UN2A THREAD

SEE COIL DATAFOR TERMINATIONS

3.57 [90.7]

MANUAL OVERRIDE

STANDARD

DE

LTA PO

WE

R C

O.

.41 [10.3] DIA.MTG. HOLES2X

#12 SAE PORTS2X

1.00 [25.4]

2.00 [50.8]

2.90 [73.7]

1.22 [30.9]

3.00 [76.2]

.28 [7.1]

2.44 [61.9]3.00

[76.2]

2.25 [57.2]

.96 [24.4]

BODY WEIGHT: 1.29 lbs (.58 kg)

Page 70: SOLENOID OPERATED DIRECTIONAL … 1000 38 69 7/8-14 DE-S2F SD18 2 WAY 2 POSITION NORMALLY CLOSED POPPET VALVES SLID PRATD DIRTIAL TRLS Page SD3 Via Malavolti, 36 • 41122 Modena •

SOLENOID OPERATED DIRECTIONAL CONTROLS

Page SD74

Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512 mail: [email protected] • www.tecnord.com

4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 mail: [email protected] • www.delta-power.com

WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken without independent study, evaluation, and testing for suitability.

W 20 / 2018

HJ-S2C PILOT OPERATED POPPET, 2 WAY NORMALLY OPEN

DESCRIPTION“High Pressure” 16 size, 1 5/16-12 thread, “Super” series, solenoid operated, 2 way normally open, pilot operated poppet valve with free reverse flow energized.

OPERATIONWhen de-energized the HJ-S2C allows flow to pass from (1) to (2), but restricts flow from (2) to (1). When energized the valve blocks flow from (1) to (2) but allows free reverse flow from (2) to (1).

FEATURES • Hardened parts for long life.• Efficient wet-armature construction.• Cartridges are voltage interchangeable.• Industry common cavity.• Unitized, molded coil design.• Continuous duty rated solenoid.• Optional coil voltages and terminations.

Nominal Flow 40 GPM (151 LPM)Rated Operating Pressure 4350 PSI (300 bar)Typical Internal Leakage (150 SSU) 0-10 drops/minViscosity Range 36 to 3000 SSU (3 to 647 cSt)Filtration ISO 18/16/13Media Operating Temp. Range -40° to 250°F (-40° to 120°C)Weight .74 lbs (.33 kg)Operating Fluid Media General Purpose Hydraulic FluidCartridge Torque Requirements 115 ft-lbs (156 Nm)Coil Nut Torque Requirements 4-6 ft-lbs (5.4-8.1 Nm)Cavity SUPER 2WCavity Tools Kit (form tool, reamer, tap) 40500017Seal Kit 21191400

VALVE SPECIFICATIONS

Actual Test Data (Cartridge Only)

0 25 50 75 100 125 150

0

5

10

0

50

100

150

0 5 10 15 20 25 30 35 40 45

Flow (LPM)

Pre

ssur

e D

rop

(bar

)

Pre

ssur

e D

rop

(PS

I)

Flow (GPM)

Port 1 to 2 (de-eng) Port 2 to 1 (eng)

PERFORMANCE

HYDRAULIC SYMBOL

2

1

Page 71: SOLENOID OPERATED DIRECTIONAL … 1000 38 69 7/8-14 DE-S2F SD18 2 WAY 2 POSITION NORMALLY CLOSED POPPET VALVES SLID PRATD DIRTIAL TRLS Page SD3 Via Malavolti, 36 • 41122 Modena •

SOLENOID OPERATED DIRECTIONAL CONTROLS

Page SD75

Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512 mail: [email protected] • www.tecnord.com

4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 mail: [email protected] • www.delta-power.com

WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken without independent study, evaluation, and testing for suitability.

W 2

0 /

2018

DIMENSIONS

ORDERING INFORMATIONApproximate Coil Weight: .74 lbs (.33 kg)

Note: Aluminum, NOT durability rated for 4350 PSI. Consult factory for body options.

OPTIONS BODIESBuna Standard 00 Blank Without BodyViton Standard V0 N 3/4 NPTF Ports

S #12 SAE Ports

VOLTAGE06 6 VDC12 12 VDC24 24 VDC36 36 VDC48 48 VDC25 24 VAC11 120 VAC

“D” COIL TERMINATION 22 220 VAC(All DC Except as Noted) 44 440 VAC

DL Double Lead SS Single SpadeDT Deutsch on Leads DT04-2P DS Double SpadeML Metri-Pack on Leads HC DIN 43650 (Hirschmann) - (AC&DC)PL Packard on Leads CL Conduit Lead - (AC Only)WL Weatherpack on Leads DI Deutsch - Integral DT04-2P

HJ-S2C – – – –

Page 72: SOLENOID OPERATED DIRECTIONAL … 1000 38 69 7/8-14 DE-S2F SD18 2 WAY 2 POSITION NORMALLY CLOSED POPPET VALVES SLID PRATD DIRTIAL TRLS Page SD3 Via Malavolti, 36 • 41122 Modena •

SOLENOID OPERATED DIRECTIONAL CONTROLS

Page SD76

Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512 mail: [email protected] • www.tecnord.com

4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 mail: [email protected] • www.delta-power.com

WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken without independent study, evaluation, and testing for suitability.

W 20 / 2018

PB-S2D PILOT OPERATED POPPET, 2 WAY NORMALLY OPEN

DESCRIPTION8 size, 3/4-16 thread, “Power” series, solenoid operated, 2 way normally open, pilot operated poppet valve with free reverse flow energized and de-energized.

OPERATIONWhen de-energized the PB-S2D allows flow from (1) to (2) or (2) to (1). When energized the valve blocks flow from (1) to (2) and allows flow from (2) to (1).OPERATION OF MANUAL OVERRIDE OPTION: to override, turn the manual override screw clockwise.To release turn the manual override screw counterclockwise.

FEATURES • Hardened parts for long life.• Efficient wet-armature construction.• Cartridges are voltage interchangeable.• Manual override option.• Industry common cavity.• Unitized, molded coil design.• Continuous duty rated solenoid.• Optional coil voltages and terminations.• Optional “I” Coil: Weatherproof, Thermal Shock, Immersion Safe.

Nominal Flow 10 GPM (38 LPM)Rated Operating Pressure 3500 PSI (241 bar)Typical Internal Leakage (150 SSU) 0-5 drops/minViscosity Range 36 to 3000 SSU (3 to 647 cSt)Filtration ISO 18/16/13Media Operating Temp. Range -40° to 250°F (-40° to 120°C)Weight .22 lbs (.10 kg)Operating Fluid Media General Purpose Hydraulic FluidCartridge Torque Requirements 25 ft-lbs (34 Nm)Coil Nut Torque Requirements 4-6 ft-lbs (5.4-8.1 Nm)Cavity POWER 2WCavity Tools Kit (form tool, reamer, tap) 40500005Seal Kit 21191100

Actual Test Data (Cartridge Only)

VALVE SPECIFICATIONS

0

50

100

150

200

250

0 2 4 6 8 10 12

Pre

ssur

e D

rop

(PS

I)

0

5

10

15

Flow (GPM)

0 10 20 30 40

Pre

ssur

e D

rop

(bar

)

Flow (LPM)

Port 1 to 2 (de-eng) Port 2 to 1 (de-eng) Port 2 to 1 (eng)

Unshifted limit of 10 GPM (38 LPM) from (1) to (2) energized and from (2) to (1) de-energized. For shifted flow performance consult chart.

PERFORMANCE

HYDRAULIC SYMBOL

2

1

Page 73: SOLENOID OPERATED DIRECTIONAL … 1000 38 69 7/8-14 DE-S2F SD18 2 WAY 2 POSITION NORMALLY CLOSED POPPET VALVES SLID PRATD DIRTIAL TRLS Page SD3 Via Malavolti, 36 • 41122 Modena •

SOLENOID OPERATED DIRECTIONAL CONTROLS

Page SD77

Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512 mail: [email protected] • www.tecnord.com

4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 mail: [email protected] • www.delta-power.com

WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken without independent study, evaluation, and testing for suitability.

W 2

0 /

2018

DIMENSIONS

ORDERING INFORMATIONApproximate Coil Weight: .42 lbs (.19 kg)

OPTIONS BODIESBuna Standard 00 Blank Without BodyViton Standard V0 N 1/4 NPTF Ports

Buna, Override, Detent 0M S #6 SAE PortsViton, Override, Detent VMBuna, Override, Knob 0KViton, Override, Knob VK

Buna, Screen A0Viton, Screen W0 VOLTAGE

Buna, Screen, Override B2 06 6 VDCViton, Screen, Override V2 12 12 VDC

Buna, Screen, Override, Knob B5 24 24 VDCViton, Screen, Override, Knob V5 36 36 VDC

48 48 VDCNote: use screen only if flow 25 24 VAC

direction is from (1) to (2) 11 120 VAC22 220 VAC

“P” COIL TERMINATION 44 440 VAC(All DC Except as Noted)

IMMERSION PROOF “P” TYPEDL Double Lead SS Single Spade IA “I” Coil AMP Superseal - IntegralDT Deutsch on Leads DT04-2P DS Double Spade ID “I” Coil Deutsch - Integral DT04-2PML Metri-Pack on Leads HC DIN 43650 (Hirschmann) - (AC&DC) IJ “I” Coil AMP Jr. Timer - IntegralPL Packard on Leads CL Conduit Lead - (AC Only) IM “I” Coil Metri-Pack - IntegralWL Weatherpack on Leads DI Deutsch - Integral DT04-2P

PB-S2D – – – –

1.25 [31.7]

1.54 [39.1]

.75 [19.0]

HEX NUT

DE

LTA P

OW

ER

CO

.

SEE COIL DATAFOR TERMINATIONS

.25 [6.3]

1.09 [27.8]

2.53 [64.3]

2.88 [73.2]

.87 [22.1] HEX

3/4-16 UNF-2ATHREAD

#12-24 UNC-2A THREAD

MANUAL OVERRIDE

STANDARD

3.16 [80.3]

OVERRIDE W/KNOB

2.00 [50.8]

#6 SAE PORT2X

2.00 [50.8]

1.50 [38.1]

.25 [6.4]

.25 [6.4]

1.52 [38.5]

.28 [7.1] DIA.MTG. HOLES2X

1.75 [44.5]

.50 [12.7]

DE

LTA P

OW

ER

CO

.

BODY WEIGHT: .39 lbs (.18 kg)

1.13 [28.6]

.63 [15.9]

1.25 [31.8]

2.50 [63.4]

Page 74: SOLENOID OPERATED DIRECTIONAL … 1000 38 69 7/8-14 DE-S2F SD18 2 WAY 2 POSITION NORMALLY CLOSED POPPET VALVES SLID PRATD DIRTIAL TRLS Page SD3 Via Malavolti, 36 • 41122 Modena •

SOLENOID OPERATED DIRECTIONAL CONTROLS

Page SD78

Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512 mail: [email protected] • www.tecnord.com

4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 mail: [email protected] • www.delta-power.com

WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken without independent study, evaluation, and testing for suitability.

W 20 / 2018

HB-S2D PILOT OPERATED POPPET, 2 WAY NORMALLY OPEN

DESCRIPTION8 size, 3/4-16 thread, “Power” series, solenoid operated, 2 way normally open, pilot operated poppet valve with reverse flow energized and de-energized.

OPERATIONWhen de-energized the HB-S2D allows flow from (1) to (2) or from (2) to (1). When energized the valve blocks flow from (1) to (2) and allows flow from (2) to (1).MANUAL OVERRIDE OPTION: to override, turn the manual override screw clockwise. To release, turn the manual override screw counter-clockwise.

FEATURES • Hardened parts for long life.• Efficient wet-armature construction.• Cartridges are voltage interchangeable.• Manual override option.• Industry common cavity.• Unitized, molded coil design.• Continuous duty rated solenoid.• Optional coil voltages and terminations.• Optional “I” Coil: Weatherproof, Thermal Shock, Immersion Safe.

Nominal Flow 12 GPM (45 LPM)Rated Operating Pressure 5000 PSI (345 bar)Typical Internal Leakage 0-5 drops/min at 5000 PSI (150 SSU) (345 bar)Viscosity Range 36 to 3000 SSU (3 to 647 cSt)Filtration ISO 18/16/13Media Operating Temp. Range -40° to 210°F (-40° to 100°C) BUNA seals -4° to 250°F (-20° to 120°C) VITON sealsWeight .29 lbs (.13 kg)Operating Fluid Media General Purpose Hydraulic FluidCartridge Torque Requirements 35 ft-lbs (47 Nm)Coil Nut Torque Requirements 4-6 ft-lbs (5.4-8.1 Nm)Cavity POWER 2WCavity Tools Kit 40500005Seal Kit 21191100

Actual Test Data (Cartridge Only)

VALVE SPECIFICATIONS

Pre

ssur

e D

rop

(PS

I)

Flow (GPM)

Pre

ssur

e D

rop

(bar

)

Flow (LPM)

PERFORMANCE

HYDRAULIC SYMBOL

TECNORDSERVOCOMANDI E REGOLAZIONE

Page 75: SOLENOID OPERATED DIRECTIONAL … 1000 38 69 7/8-14 DE-S2F SD18 2 WAY 2 POSITION NORMALLY CLOSED POPPET VALVES SLID PRATD DIRTIAL TRLS Page SD3 Via Malavolti, 36 • 41122 Modena •

SOLENOID OPERATED DIRECTIONAL CONTROLS

Page SD79

Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512 mail: [email protected] • www.tecnord.com

4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 mail: [email protected] • www.delta-power.com

WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken without independent study, evaluation, and testing for suitability.

W 2

0 /

2018

DIMENSIONS

ORDERING INFORMATIONApproximate Coil Weight: .42 lbs (.19 kg)

“P” COIL IMMERSION PROOF “I” COIL

HB-S2D – – – –

Note: Aluminum Body Not durability rated for 5000 PSI (345 bar), consult factory for high pressure body options.

TECNORDSERVOCOMANDI E REGOLAZIONE

TECNORDSERVOCOMANDI E REGOLAZIONE

OPTIONS BODIESBuna Standard 00 Blank Without BodyViton Standard V0 N 1/4 NPTF Ports

Buna, Override, Knob 0K S #6 SAE PortsViton, Override, Knob VK

Buna, Screen A0 VOLTAGEViton, Screen W0 06 6 VDC

Buna, Screen, Override, Knob B5 12 12 VDCViton, Screen, Override, Knob V5 24 24 VDC

36 36 VDC48 48 VDC

Note: use screen only if flow 25 24 VACdirection is from (1) to (2) 11 120 VAC

22 220 VAC44 440 VAC

“P” COIL TERMINATION IMMERSION PROOF “I” COIL TERMINATION

DL Double Lead SS Single Spade IA “I” Coil AMP Superseal - IntegralDT Deutsch on Leads DT04-2P DS Double Spade ID “I” Coil Deutsch - Integral DT04-2PML Metri-Pack on Leads HC DIN 43650 (Hirschmann) - (AC&DC) IJ “I” Coil AMP Jr. Timer - IntegralPL Packard on Leads CL Conduit Lead - (AC Only) IM “I” Coil Metri-Pack - IntegralWL Weatherpack on Leads DI Deutsch - Integral DT04-2P

For Optional Coil Terminations See Coil Section

Page 76: SOLENOID OPERATED DIRECTIONAL … 1000 38 69 7/8-14 DE-S2F SD18 2 WAY 2 POSITION NORMALLY CLOSED POPPET VALVES SLID PRATD DIRTIAL TRLS Page SD3 Via Malavolti, 36 • 41122 Modena •

SOLENOID OPERATED DIRECTIONAL CONTROLS

Page SD80

Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512 mail: [email protected] • www.tecnord.com

4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 mail: [email protected] • www.delta-power.com

WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken without independent study, evaluation, and testing for suitability.

W 20 / 2018

DE-S2D PILOT OPERATED POPPET, 2 WAY NORMALLY OPEN

DESCRIPTION10 size, 7/8-14 thread, “Delta” series, solenoid operated, 2 way normally open, pilot operated poppet valve with free reverse flow energized and de-energized.

OPERATIONWhen de-energized the DE-S2D allows flow to pass from (1) to (2) and (2) to (1). When energized the valve blocks flow from (1) to (2) but allows free reverse flow from (2) to (1).OPERATION OF MANUAL OVERRIDE OPTION: to override, turn the manual override screw clockwise.To release turn the turn the manual override screw counterclockwise.

FEATURES • Hardened parts for long life.• Efficient wet-armature construction.• Cartridges are voltage interchangeable.• Manual override option.• Industry common cavity.• Unitized, molded coil design.• Continuous duty rated solenoid.• Optional coil voltages and terminations.• Optional “I” Coil: Weatherproof, Thermal Shock, Immersion Safe.

Nominal Flow 15 GPM (57 LPM)Rated Operating Pressure 3500 PSI (241 bar)Typical Internal Leakage (150 SSU) 0-5 drops/minViscosity Range 36 to 3000 SSU (3 to 647 cSt)Filtration ISO 18/16/13Media Operating Temp. Range -40° to 250°F (-40° to 120°C)Weight .29 lbs (.13 kg)Operating Fluid Media General Purpose Hydraulic FluidCartridge Torque Requirements 30 ft-lbs (40.6 Nm)Coil Nut Torque Requirements 4-6 ft-lbs (5.4-8.1 Nm)Cavity DELTA 2WCavity Tools Kit (form tool, reamer, tap) 40500000Seal Kit 21191200

Actual Test Data (Cartridge Only)

VALVE SPECIFICATIONS

0

50

100

150

200

0

250

5 10 15 20

Pre

ssur

e D

rop

(PS

I)

0

5

10

15

0 25 50 75

Pre

ssur

e D

rop

(bar

)

Flow (LPM)

Port 1 to 2 (de-eng)

Flow (GPM)

Port 2 to 1 (de-eng) Port 2 to 1 (eng)

PERFORMANCE

HYDRAULIC SYMBOL

2

1

Page 77: SOLENOID OPERATED DIRECTIONAL … 1000 38 69 7/8-14 DE-S2F SD18 2 WAY 2 POSITION NORMALLY CLOSED POPPET VALVES SLID PRATD DIRTIAL TRLS Page SD3 Via Malavolti, 36 • 41122 Modena •

SOLENOID OPERATED DIRECTIONAL CONTROLS

Page SD81

Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512 mail: [email protected] • www.tecnord.com

4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 mail: [email protected] • www.delta-power.com

WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken without independent study, evaluation, and testing for suitability.

W 2

0 /

2018

DIMENSIONS

ORDERING INFORMATIONApproximate Coil Weight: .74 lbs (.33 kg)

OPTIONS BODIESBuna Standard 00 Blank Without BodyViton Standard V0 N 3/8 NPTF Ports

Buna, Override, Detent 0M S #8 SAE PortsViton, Override, Detent VMBuna, Override, Knob 0KViton, Override, Knob VK

Buna, Screen A0Viton, Screen W0 VOLTAGE

Buna, Screen, Override B2 06 6 VDCViton, Screen, Override V2 12 12 VDC

Buna, Screen, Override, Knob B5 24 24 VDCViton, Screen, Override, Knob V5 36 36 VDC

48 48 VDCNote: use screen only if flow 25 24 VAC

direction is from (1) to (2) 11 120 VAC22 220 VAC

“D” COIL TERMINATION 44 440 VAC(All DC Except as Noted)

IMMERSION PROOF “D” TYPEDL Double Lead SS Single Spade IA “I” Coil AMP Superseal - IntegralDT Deutsch on Leads DT04-2P DS Double Spade ID “I” Coil Deutsch - Integral DT04-2PML Metri-Pack on Leads HC DIN 43650 (Hirschmann) - (AC&DC) IJ “I” Coil AMP Jr. Timer - IntegralPL Packard on Leads CL Conduit Lead - (AC Only) IM “I” Coil Metri-Pack - IntegralWL Weatherpack on Leads DI Deutsch - Integral DT04-2P

DE-S2D – – – – H

YD

RA

ULIC

CO

.

.22 [5.6]

2.72 [69.2]

1.25 [31.7]

3.12[79.2]

1.56 [39.6]

SEE COIL DATAFOR TERMINATIONS

1.84 [46.6]

7/8-14 UNF 2ATHREAD

.75 [19.1]HEX NUT

1.00 [25.4] HEX

SOLENOID OPERATED DIRECTIONAL CONTROLS

Page SD81

Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512 mail: [email protected] • www.tecnord.com

4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 mail: [email protected] • www.delta-power.com

WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken without independent study, evaluation, and testing for suitability.

W 1

8 /

2017

DIMENSIONS

ORDERING INFORMATIONApproximate Coil Weight: .74 lbs (.33 kg)

OPTIONS BODIESBuna Standard 00 Blank Without BodyViton Standard V0 N 3/8 NPTF Ports

Buna, Override, Detent 0M S #8 SAE PortsViton, Override, Detent VMBuna, Override, Knob 0KViton, Override, Knob VK

Buna, Screen A0Viton, Screen W0 VOLTAGE

Buna, Screen, Override B2 06 6 VDCViton, Screen, Override V2 12 12 VDC

Buna, Screen, Override, Knob B5 24 24 VDCViton, Screen, Override, Knob V5 36 36 VDC

48 48 VDCNote: use screen only if flow 25 24 VAC

direction is from (1) to (2) 11 120 VAC22 220 VAC

“D” COIL TERMINATION 44 440 VAC(All DC Except as Noted)

IMMERSION PROOF “D” TYPEDL Double Lead SS Single Spade IA “I” Coil AMP Superseal - IntegralDT Deutsch on Leads DT04-2P DS Double Spade ID “I” Coil Deutsch - Integral DT04-2PML Metri-Pack on Leads HC DIN 43650 (Hirschmann) - (AC&DC) IJ “I” Coil AMP Jr. Timer - IntegralPL Packard on Leads CL Conduit Lead - (AC Only) IM “I” Coil Metri-Pack - IntegralWL Weatherpack on Leads DI Deutsch - Integral DT04-2P

DE-S2D – – – – H

YD

RA

ULIC

CO

.

.22 [5.6]

2.72 [69.2]

1.25 [31.7]

3.12[79.2]

1.56 [39.6]

SEE COIL DATAFOR TERMINATIONS

1.84 [46.6]

7/8-14 UNF 2ATHREAD

.75 [19.1]HEX NUT

1.00 [25.4] HEX

SOLENOID OPERATED DIRECTIONAL CONTROLS Delta Power Company4484 Boeing Drive - Rockford, IL 61109

WARNING: The specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken without independent study, evaluation, and testing for suitability.

Phone: (815) 397-6628 Fax: (815) 397-2526 E-mail: [email protected]

DIMENSIONS

ORDERING INFORMATION DE-S2D - - - -

OPTIONS BODIES

Buna Standard 00 Blank Without Body Viton Standard V0 N 3/8 NPTF Ports Buna, Override 0M S #8 SAE Ports Viton, Override VM

Buna, Override, Knob OK Viton, Override, Knob VK VOLTAGE

Buna, Screen A0 06 6 VDC Viton, Screen W0 12 12 VDC

Buna, Screen, Override B2 24 24 VDC Viton, Screen, Override V2 36 36 VDC

Buna, Screen, Override, Knob B5 48 48 VDC Viton, Screen, Override, Knob V5 25 24 VAC

11 120 VAC 22 220 VAC Note: Use screen only if flow direction

is from (1) to (2). 44 440 VAC

“D” COIL TERMINATION (All DC Except as Noted)

IMMERSION PROOF “D” TYPE DL Double Lead SS Single Spade IA “I” Coil AMP Superseal - Integral DT Deutsch on Leads DT04-2P DS Double Spade ID “I” Coil Deutsch – Integral DT04-2P MI Metri-Pack on Leads HC DIN 43650 (Hirschmann) – (AC & DC) IJ “I” Coil AMP Jr. Timer - Integral PI Packard on Leads CL Conduit Lead – (AC Only) IM “I” Coil Metri-Pack - Integral WL Weatherpack on Leads DI Deutsch – Integral DT04-2P

Approximate Coil Weight: .74 lbs/.33 kg.

Page 95

Page 78: SOLENOID OPERATED DIRECTIONAL … 1000 38 69 7/8-14 DE-S2F SD18 2 WAY 2 POSITION NORMALLY CLOSED POPPET VALVES SLID PRATD DIRTIAL TRLS Page SD3 Via Malavolti, 36 • 41122 Modena •

SOLENOID OPERATED DIRECTIONAL CONTROLS

Page SD82

Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512 mail: [email protected] • www.tecnord.com

4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 mail: [email protected] • www.delta-power.com

WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken without independent study, evaluation, and testing for suitability.

W 20 / 2018

TT-S2D PILOT OPERATED POPPET, 2 WAY NORMALLY OPEN

DESCRIPTION12 size, 1 1/16-12 thread, “Tecnord” series, solenoid operated, 2 way normally open, pilot operated poppet valve with free reverse flow energized and de-energized.

OPERATIONWhen de-energized the TT-S2D allows flow to pass from (1) to (2) and (2) to (1). When energized the valve blocks flow from (1) to (2) but allows free reverse flow from (2) to (1).OPERATION OF MANUAL OVERRIDE OPTION: to override, turn the manual override screw clockwise.To release turn the manual override screw counterclockwise.

FEATURES • Hardened parts for long life.• Efficient wet-armature construction.• Cartridges are voltage interchangeable.• Manual override option.• Industry common cavity.• Unitized, molded coil design.• Continuous duty rated solenoid.• Optional coil voltages and terminations.• Optional “I” Coil: Weatherproof, Thermal Shock, Immersion Safe.

Nominal Flow 30 GPM (114 LPM)Rated Operating Pressure 3000 PSI (207 bar)Typical Internal Leakage (150 SSU) 0-10 drops/minViscosity Range 36 to 3000 SSU (3 to 647 cSt)Filtration ISO 18/16/13Media Operating Temp. Range -40° to 250°F (-40° to 120°C)Weight .51 lbs (.23 kg)Operating Fluid Media General Purpose Hydraulic FluidCartridge Torque Requirements 70 ft-lbs (94.9 Nm)Coil Nut Torque Requirements 4-6 ft-lbs (4.5-8.1 Nm)Cavity TECNORD 2WCavity Tools Kit (form tool, reamer, tap) 40500032Seal Kit 21191300

Actual Test Data (Cartridge Only)

VALVE SPECIFICATIONS

0

50

100

150

200

250

0 10 20 30 400

5

10

15

Pre

ssur

e D

rop

(PS

I)

0 5025 75 100 125 150Flow (LPM)

Pre

ssur

e D

rop

(bar

)

Flow (GPM)

Port 1 to 2 (de-eng) Port 2 to 1 (eng)Port 2 to 1 (de-eng)

PERFORMANCE

HYDRAULIC SYMBOL

2

1

Page 79: SOLENOID OPERATED DIRECTIONAL … 1000 38 69 7/8-14 DE-S2F SD18 2 WAY 2 POSITION NORMALLY CLOSED POPPET VALVES SLID PRATD DIRTIAL TRLS Page SD3 Via Malavolti, 36 • 41122 Modena •

SOLENOID OPERATED DIRECTIONAL CONTROLS

Page SD83

Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512 mail: [email protected] • www.tecnord.com

4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 mail: [email protected] • www.delta-power.com

WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken without independent study, evaluation, and testing for suitability.

W 2

0 /

2018

DIMENSIONS

ORDERING INFORMATIONApproximate Coil Weight: .74 lbs (.33 kg)

OPTIONS BODIESBuna Standard 00 Blank Without BodyViton Standard V0 S #12 SAE Ports

Buna, Override, Knob 0KViton, Override, Knob VK

Buna, Screen A0Viton, Screen W0

Buna, Screen, Override, Knob B5Viton, Screen, Override, Knob V5 VOLTAGE

06 6 VDC12 12 VDC

Note: use screen only if flow 24 24 VDCdirection is from (1) to (2) 36 36 VDC

48 48 VDC25 24 VAC11 120 VAC22 220 VAC

“D” COIL TERMINATION 44 440 VAC(All DC Except as Noted)

IMMERSION PROOF “D” TYPEDL Double Lead SS Single Spade IA “I” Coil AMP Superseal - IntegralDT Deutsch on Leads DT04-2P DS Double Spade ID “I” Coil Deutsch - Integral DT04-2PML Metri-Pack on Leads HC DIN 43650 (Hirschmann) - (AC&DC) IJ “I” Coil AMP Jr. Timer - IntegralPL Packard on Leads CL Conduit Lead - (AC Only) IM “I” Coil Metri-Pack - IntegralWL Weatherpack on Leads DI Deutsch - Integral DT04-2P

TT-S2D – – – –

DE

LTA P

OW

ER

CO

.

STANDARD

1 1/16-12 UN-2ATHREAD

1.25 [31.7] HEX

SEE COIL DATAFOR TERMINATIONS

1.83 [46.6]

.75 [19.0]

HEX NUT

1.56 [39.6]

1.90 [48.2]

3.00 [76.2]

3.50 [88.8]

.36 [9.2]

MANUAL OVERRIDE

DE

LTA P

OW

ER

CO

.

#12 SAE PORTS2X

.41 [10.3] DIA.MTG. HOLES2X

BODY WEIGHT: 3.71 lbs (1.68 kg)

.88 [22.4]

1.81 [46.0]

1.06 [27.0]

2.87 [72.9]

3.09 [78.5]

1.03 [26.2]

2.25 [57.2]

2.69 [68.4]

.17 [4.3]

2.20 [55.9]

Page 80: SOLENOID OPERATED DIRECTIONAL … 1000 38 69 7/8-14 DE-S2F SD18 2 WAY 2 POSITION NORMALLY CLOSED POPPET VALVES SLID PRATD DIRTIAL TRLS Page SD3 Via Malavolti, 36 • 41122 Modena •

SOLENOID OPERATED DIRECTIONAL CONTROLS

Page SD84

Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512 mail: [email protected] • www.tecnord.com

4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 mail: [email protected] • www.delta-power.com

WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken without independent study, evaluation, and testing for suitability.

W 20 / 2018

SJ-S2D PILOT OPERATED POPPET, 2 WAY NORMALLY OPEN

DESCRIPTION16 size, 1 5/16-12 thread, “Super” series, solenoid operated, 2 way normally open, pilot operated poppet valve with free reverse flow energized and de-energized.

OPERATIONWhen de-energized the SJ-S2D allows flow to pass from (1) to (2), and (2) to (1). When energized the valve blocks flow from (1) to (2) but allows free reverse flow from (2) to (1).

FEATURES • Hardened parts for long life.• Efficient wet-armature construction.• Cartridges are voltage interchangeable.• Industry common cavity.• Unitized, molded coil design.• Continuous duty rated solenoid.• Optional coil voltages and terminations.• Optional “I” Coil: Weatherproof, Thermal Shock, Immersion Safe.

Nominal Flow 40 GPM (151 LPM)Rated Operating Pressure 3000 PSI (207 bar)Typical Internal Leakage (150 SSU) 0-10 drops/minViscosity Range 36 to 3000 SSU (3 to 647 cSt)Filtration ISO 18/16/13Media Operating Temp. Range -40° to 250°F (-40° to 120°C)Weight .74 lbs (.33 kg)Operating Fluid Media General Purpose Hydraulic FluidCartridge Torque Requirements 90 ft-lbs (122 Nm)Coil Nut Torque Requirements 4-6 ft-lbs (5.4-8.1 Nm)Cavity SUPER 2WCavity Tools Kit (form tool, reamer, tap) 40500017Seal Kit 21191400

Actual Test Data (Cartridge Only)

VALVE SPECIFICATIONS

0

50

100

0

150

10 20 30 400

5

Pre

ssur

e D

rop

(PS

I)

10

0 25 7550 125100 150

Flow (LPM)

Pre

ssur

e D

rop

(bar

)

Port 1 to 2 (de-eng) Port 2 to 1 (eng)

Flow (GPM)

Port 2 to 1 (de-eng)

PERFORMANCE

HYDRAULIC SYMBOL

2

1

Page 81: SOLENOID OPERATED DIRECTIONAL … 1000 38 69 7/8-14 DE-S2F SD18 2 WAY 2 POSITION NORMALLY CLOSED POPPET VALVES SLID PRATD DIRTIAL TRLS Page SD3 Via Malavolti, 36 • 41122 Modena •

SOLENOID OPERATED DIRECTIONAL CONTROLS

Page SD85

Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512 mail: [email protected] • www.tecnord.com

4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 mail: [email protected] • www.delta-power.com

WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken without independent study, evaluation, and testing for suitability.

W 2

0 /

2018

SOLENOID OPERATED DIRECTIONAL CONTROLS

Page SD85

Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512 mail: [email protected] • www.tecnord.com

4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 mail: [email protected] • www.delta-power.com

WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken without independent study, evaluation, and testing for suitability.

W 1

8 /

2017

SOLENOID OPERATED DIRECTIONAL CONTROLS Delta Power Company4484 Boeing Drive - Rockford, IL 61109

WARNING: The specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken without independent study, evaluation, and testing for suitability.

Phone: (815) 397-6628 Fax: (815) 397-2526 E-mail: [email protected]

DIMENSIONS

DE

LTA PO

WE

R C

O.

.41 [10.3] DIA.MTG. HOLES2X

#12 SAE PORTS2X

BODY WEIGHT: 1.29 lbs [.58 kg]

1.00 [25.4]

2.00 [50.8]

2.90 [73.7]

1.22 [30.9]

3.00 [76.2]

.28 [7.1]

2.44 [61.9]3.00

[76.2]

2.25 [57.2]

.96 [24.4]

ORDERING INFORMATION SJ-S2D - - - -

OPTIONS BODIES

Buna Standard 00 Blank Without Body Viton Standard V0 N 3/4 NPTF Ports

Buna, Screen A0 S #12 SAE Ports Viton, Screen W0

Buna, Override 0K VOLTAGEViton, Override VK 06 6 VDC

Buna, Screen, Override B2 12 12 VDCViton, Screen, Override V2 24 24 VDC

36 36 VDC 48 48 VDC Note: Use screen only if flow direction

is from (1) to (2). 25 24 VAC 11 120 VAC 22 220 VAC 44 440 VAC

“D” COIL TERMINATION (All DC Except as Noted)

IMMERSION PROOF “D” TYPE DL Double Lead SS Single Spade IA “I” Coil AMP Superseal – Integral DT Deutsch on Leads DT04—2P DS Double Spade ID “I” Coil Deutsch – Integral DT04-2P MI Metri-Pack on Leads HC Din 43650 (Hirschmann) – (AC & DC) IJ “I” Coil AMP Jr. Timer – Integral PI Packard on Leads CL Conduit Lead – (AC Only) IM “I” Coil Metri-Pack – Integral WL Weatherpack on Leads DI Deutsch – Integral DT04—2P

Approximate Coil Weight: .74 lbs/.33 kg.

Page 99

DIMENSIONS

ORDERING INFORMATIONApproximate Coil Weight: .74 lbs (.33 kg)

OPTIONS BODIESBuna Standard 00 Blank Without BodyViton Standard V0 N 3/4 NPTF PortsBuna, Override 0K S #12 SAE PortsViton, Override VK

Buna, Screen A0Viton, Screen W0

Buna, Screen, Override B2Viton, Screen, Override V2 VOLTAGE

06 6 VDC12 12 VDC

Note: use screen only if flow 24 24 VDCdirection is from (1) to (2) 36 36 VDC

48 48 VDC25 24 VAC11 120 VAC22 220 VAC

“D” COIL TERMINATION 44 440 VAC(All DC Except as Noted)

IMMERSION PROOF “D” TYPEDL Double Lead SS Single Spade IA “I” Coil AMP Superseal - IntegralDT Deutsch on Leads DT04-2P DS Double Spade ID “I” Coil Deutsch - Integral DT04-2PML Metri-Pack on Leads HC DIN 43650 (Hirschmann) - (AC&DC) IJ “I” Coil AMP Jr. Timer - IntegralPL Packard on Leads CL Conduit Lead - (AC Only) IM “I” Coil Metri-Pack - IntegralWL Weatherpack on Leads DI Deutsch - Integral DT04-2P

SJ-S2D – – – –

DIMENSIONS

ORDERING INFORMATIONApproximate Coil Weight: .74 lbs (.33 kg)

OPTIONS BODIESBuna Standard 00 Blank Without BodyViton Standard V0 N 3/4 NPTF PortsBuna, Override 0K S #12 SAE PortsViton, Override VK

Buna, Screen A0Viton, Screen W0

Buna, Screen, Override B2Viton, Screen, Override V2 VOLTAGE

06 6 VDC12 12 VDC

Note: use screen only if flow 24 24 VDCdirection is from (1) to (2) 36 36 VDC

48 48 VDC25 24 VAC11 120 VAC22 220 VAC

“D” COIL TERMINATION 44 440 VAC(All DC Except as Noted)

IMMERSION PROOF “D” TYPEDL Double Lead SS Single Spade IA “I” Coil AMP Superseal - IntegralDT Deutsch on Leads DT04-2P DS Double Spade ID “I” Coil Deutsch - Integral DT04-2PML Metri-Pack on Leads HC DIN 43650 (Hirschmann) - (AC&DC) IJ “I” Coil AMP Jr. Timer - IntegralPL Packard on Leads CL Conduit Lead - (AC Only) IM “I” Coil Metri-Pack - IntegralWL Weatherpack on Leads DI Deutsch - Integral DT04-2P

SJ-S2D – – – –

Page 82: SOLENOID OPERATED DIRECTIONAL … 1000 38 69 7/8-14 DE-S2F SD18 2 WAY 2 POSITION NORMALLY CLOSED POPPET VALVES SLID PRATD DIRTIAL TRLS Page SD3 Via Malavolti, 36 • 41122 Modena •

SOLENOID OPERATED DIRECTIONAL CONTROLS

Page SD86

Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512 mail: [email protected] • www.tecnord.com

4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 mail: [email protected] • www.delta-power.com

WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken without independent study, evaluation, and testing for suitability.

W 20 / 2018

HB-S2K PILOTED OPERATED POPPET, 2 WAY DOUBLE LOCK NORMALLY OPEN

DESCRIPTION8 size, 3/4-16 thread, “Power” series, solenoid operated, 2 way double lock normally open, pilot operated bidirectional poppet valve.

OPERATIONWhen de-energized the HB-S2K allows flow from (1) to (2) or from (2) to (1). When energized the valve blocks flow from (1) to (2) and block flow from (2) to (1).

FEATURES • Hardened parts for long life.• Efficient wet-armature construction.• Cartridges are voltage interchangeable.• Manual override option.• Industry common cavity.• Unitized, molded coil design.• Continuous duty rated solenoid.• Optional coil voltages and terminations.• 720 hour salt spray protection.

Nominal Flow 12 GPM (45 LPM)Rated Operating Pressure 5000 PSI (345 bar)Typical Internal Leakage 0-5 drops/min at 5000 PSI(150 SSU) (345 bar)Viscosity Range 36 to 3000 SSU (3 to 647 cSt)Filtration ISO 18/16/13Media Operating Temp. Range -40° to 210°F (-40° to 100°C) BUNA seals -4° to 250°F (-20° to 120°C) VITON sealsWeight .29 lbs (.13 kg)Operating Fluid Media General Purpose Hydraulic FluidCartridge Torque Requirements 30-35 ft-lbs (41-47 Nm)Coil Nut Torque Requirements 3-4.5 ft-lbs (4-6 Nm)Cavity POWER 2WCavity Tools Kit 40500005Seal Kit 21191102

Actual Test Data (Cartridge Only)

VALVE SPECIFICATIONS

Pre

ssur

e D

rop

(PS

I)

Flow (LPM)

Pre

ssur

e D

rop

(bar

)

Flow (GPM)

PERFORMANCE

HYDRAULIC SYMBOL

TECNORDSERVOCOMANDI E REGOLAZIONE

Page 83: SOLENOID OPERATED DIRECTIONAL … 1000 38 69 7/8-14 DE-S2F SD18 2 WAY 2 POSITION NORMALLY CLOSED POPPET VALVES SLID PRATD DIRTIAL TRLS Page SD3 Via Malavolti, 36 • 41122 Modena •

SOLENOID OPERATED DIRECTIONAL CONTROLS

Page SD87

Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512 mail: [email protected] • www.tecnord.com

4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 mail: [email protected] • www.delta-power.com

WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken without independent study, evaluation, and testing for suitability.

W 2

0 /

2018

DIMENSIONS

ORDERING INFORMATION

DIMENSIONS

ORDERING INFORMATION

TECNORDSERVOCOMANDI E REGOLAZIONE

TECNORDSERVOCOMANDI E REGOLAZIONE

“P” COIL IMMERSION PROOF “I” COIL

OPTIONSBuna Standard 00Viton Standard V0

Buna, Override, Knob 0KViton, Override, Knob VK

Buna, Screen A0 VOLTAGEViton, Screen W0 06 6 VDC

Buna, Screen, Override, Knob B5 12 12 VDCViton, Screen, Override, Knob V5 24 24 VDC

36 36 VDC48 48 VDC

Note: use screen only if flow 25 24 VACdirection is from (1) to (2) 11 120 VAC

22 220 VAC44 440 VAC

“P” COIL TERMINATION IMMERSION PROOF “I” COIL TERMINATION

DL Double Lead SS Single Spade IA “I” Coil AMP Superseal - IntegralDT Deutsch on Leads DT04-2P DS Double Spade ID “I” Coil Deutsch - Integral DT04-2PML Metri-Pack on Leads HC DIN 43650 (Hirschmann) - (AC&DC) IJ “I” Coil AMP Jr. Timer - IntegralPL Packard on Leads CL Conduit Lead - (AC Only) IM “I” Coil Metri-Pack - IntegralWL Weatherpack on Leads DI Deutsch - Integral DT04-2P

For Optional Coil Terminations See Coil Section

HB - S2K – – – CONSULT FACTORY FOR BODY

Approximate Coil Weight: .42 lbs (.19 kg)

Page 84: SOLENOID OPERATED DIRECTIONAL … 1000 38 69 7/8-14 DE-S2F SD18 2 WAY 2 POSITION NORMALLY CLOSED POPPET VALVES SLID PRATD DIRTIAL TRLS Page SD3 Via Malavolti, 36 • 41122 Modena •

SOLENOID OPERATED DIRECTIONAL CONTROLS

Page SD88

W 20 / 2018

Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512 mail: [email protected] • www.tecnord.com

4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 mail: [email protected] • www.delta-power.com

WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken without independent study, evaluation, and testing for suitability.

Page 85: SOLENOID OPERATED DIRECTIONAL … 1000 38 69 7/8-14 DE-S2F SD18 2 WAY 2 POSITION NORMALLY CLOSED POPPET VALVES SLID PRATD DIRTIAL TRLS Page SD3 Via Malavolti, 36 • 41122 Modena •

SOLENOID OPERATED DIRECTIONAL CONTROLS

Page SD89

W 2

0 /

2018

Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512 mail: [email protected] • www.tecnord.com

4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 mail: [email protected] • www.delta-power.com

WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken without independent study, evaluation, and testing for suitability.

2W2P NORMALLY OPEN GPM PSI LPM BAR CAVITY MODEL PAGE

1.5 4000 6 276 5/8-18 UA-S2H SD90

5 3000 19 207 3/4-16 PB-S2H SD92

8 3500 30 241 7/8-14 DE-S2H SD94

8 4000 30 276 7/8-14 HE-S2H SD96

2 WAY 2 POSITION NORMALLY OPEN SPOOL VALVES

Typical application for the S2H is to provide deceleration or unloading of a hydraulic motor.

TYPICAL SCHEMATIC

SOLENOID OPERATED DIRECTIONAL CONTROLS

Page 86: SOLENOID OPERATED DIRECTIONAL … 1000 38 69 7/8-14 DE-S2F SD18 2 WAY 2 POSITION NORMALLY CLOSED POPPET VALVES SLID PRATD DIRTIAL TRLS Page SD3 Via Malavolti, 36 • 41122 Modena •

SOLENOID OPERATED DIRECTIONAL CONTROLS

Page SD90

Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512 mail: [email protected] • www.tecnord.com

4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 mail: [email protected] • www.delta-power.com

WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken without independent study, evaluation, and testing for suitability.

W 20 / 2018

UA-S2H DIRECT ACTING SPOOL, 2 WAY NORMALLY OPEN

DESCRIPTION7 size, 5/8-18 thread, “Mini” series, solenoid operated, 2 way normally open, spool valve.

OPERATIONWhen de-energized the UA-S2H allows flow from (1) to (2) and (2) to (1). When energized, the valve blocks flow from (1) to (2) and (2) to (1).

FEATURES • Hardened parts for long life.• Efficient wet-armature construction.• Cartridges are voltage interchangeable.• Industry common cavity.• Unitized, molded coil design.• Continuous duty rated solenoid.• Optional coil voltages and terminations.

Nominal Flow 2 GPM (8 LPM) from (1) to (2) 1 GPM (4 LPM) from (2) to (1)Rated Operating Pressure 4000 PSI (276 bar)Typical Internal Leakage (150 SSU) 8 cu in/min (131 ml/min)Viscosity Range 36 to 3000 SSU (3 to 647 cSt)Filtration ISO 18/16/13Media Operating Temp. Range -40° to 250°F (-40° to 120°C)Weight .12 lbs (.05 kg)Operating Fluid Media General Purpose Hydraulic FluidCartridge Torque Requirements 15 ft-lbs (20.3 Nm)Coil Nut Torque Requirements 4-6 ft-lbs (5.4-8.1 Nm)Cavity MINI 2WCavity Form Tool (Finishing) 40500003Seal Kit 21191002

Actual Test Data (Cartridge Only)

VALVE SPECIFICATIONS

0

50

100

150

200

250

0 1 2 3 4Flow (GPM)

0

5

10

15

0 5 10

Pre

ssur

e D

rop

(PSI

)

15Flow (LPM)

Pre

ssur

e D

rop

(BAR

)

Port 1 to 2 (de-eng) Port 2 to 1 (de-eng)

0

50

100

150

200

250

0 1 2 3 4Flow (GPM)

0

5

10

15

0 5 10

Pre

ssur

e D

rop

(PSI

)

15Flow (LPM)

Pre

ssur

e D

rop

(BAR

)

Port 1 to 2 (de-eng) Port 2 to 1 (de-eng)

Uses “P” or “PI” type coils

PERFORMANCE

HYDRAULIC SYMBOL

2

1

Page 87: SOLENOID OPERATED DIRECTIONAL … 1000 38 69 7/8-14 DE-S2F SD18 2 WAY 2 POSITION NORMALLY CLOSED POPPET VALVES SLID PRATD DIRTIAL TRLS Page SD3 Via Malavolti, 36 • 41122 Modena •

SOLENOID OPERATED DIRECTIONAL CONTROLS

Page SD91

Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512 mail: [email protected] • www.tecnord.com

4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 mail: [email protected] • www.delta-power.com

WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken without independent study, evaluation, and testing for suitability.

W 2

0 /

2018

DIMENSIONS

ORDERING INFORMATIONApproximate Coil Weight: .30 lbs (.14 kg)

OPTIONS BODIESBuna Standard 00 Blank Without BodyViton Standard V0 N 1/4 NPTF PortsBuna, Screen A0 S #6 SAE PortsViton, Screen W0

Note: use screen only if flow direction is from (1) to (2)

VOLTAGE06 6 VDC12 12 VDC24 24 VDC36 36 VDC48 48 VDC25 24 VAC11 120 VAC22 220 VAC

“P” COIL TERMINATION 44 440 VAC(All DC Except as Noted)

IMMERSION PROOF “P” TYPEDL Double Lead SS Single Spade IA “I” Coil AMP Superseal - IntegralDT Deutsch on Leads DT04-2P DS Double Spade ID “I” Coil Deutsch - Integral DT04-2PML Metri-Pack on Leads HC DIN 43650 (Hirschmann) - (AC&DC) IJ “I” Coil AMP Jr. Timer - IntegralPL Packard on Leads CL Conduit Lead - (AC Only) IM “I” Coil Metri-Pack - IntegralWL Weatherpack on Leads DI Deutsch - Integral DT04-2P

UA-S2H – – – –

Note: Aluminum, NOT durability rated for 4000 PSI. Consult factory for body options.

Page 88: SOLENOID OPERATED DIRECTIONAL … 1000 38 69 7/8-14 DE-S2F SD18 2 WAY 2 POSITION NORMALLY CLOSED POPPET VALVES SLID PRATD DIRTIAL TRLS Page SD3 Via Malavolti, 36 • 41122 Modena •

SOLENOID OPERATED DIRECTIONAL CONTROLS

Page SD92

Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512 mail: [email protected] • www.tecnord.com

4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 mail: [email protected] • www.delta-power.com

WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken without independent study, evaluation, and testing for suitability.

W 20 / 2018

PB-S2H DIRECT ACTING SPOOL, 2 WAY NORMALLY OPEN

DESCRIPTION8 size, 3/4-16 thread, “Power” series, solenoid operated, 2 way normally open, spool valve.

OPERATIONWhen de-energized the PB-S2H allows flow from (1) to (2) and (2) to (1). When energized the valve blocks flow from (1) to (2) and (2) to (1).OPERATION OF MANUAL OVERRIDE OPTION: to override, pull knob out. On the detented version, after pulling knob out twist 180 degrees and release. The valve will remain in that position.

FEATURES • Hardened parts for long life.• Efficient wet-armature construction.• Cartridges are voltage interchangeable.• Manual override option.• Industry common cavity.• Unitized, molded coil design.• Continuous duty rated solenoid.• Optional coil voltages and terminations.• Optional “I” Coil: Weatherproof, Thermal Shock, Imersion Safe.

Nominal Flow 5 GPM (19 LPM) from (1) to (2) 3 GPM (11 LPM) from (2) to (1)Rated Operating Pressure 3000 PSI (207 bar)Typical Internal Leakage (150 SSU) 5 cu in/min (82 ml/min)Viscosity Range 36 to 3000 SSU (3 to 647 cSt)Filtration ISO 18/16/13Media Operating Temp. Range -40° to 250°F (-40° to 120°C)Weight .19 lbs (.09 kg)Operating Fluid Media General Purpose Hydraulic FluidCartridge Torque Requirements 25 ft-lbs (34 Nm)Coil Nut Torque Requirements 4-6 ft-lbs (5.4-8.1 Nm)Cavity POWER 2WCavity Tools Kit (form tool, reamer, tap) 40500005Seal Kit 21191102

Actual Test Data (Cartridge Only)

VALVE SPECIFICATIONS

0

50

100

150200

250

300

350

20 4 60

Pre

ssur

e D

rop

(PS

I)

5

Flow (GPM)

10

15

20

0 5 1510 20

Pre

ssur

e D

rop

(bar

)

Flow (LPM)

Port 1 to 2 (de-eng) Port 2 to 1 (de-eng)

PERFORMANCE

HYDRAULIC SYMBOL

2

1

Page 89: SOLENOID OPERATED DIRECTIONAL … 1000 38 69 7/8-14 DE-S2F SD18 2 WAY 2 POSITION NORMALLY CLOSED POPPET VALVES SLID PRATD DIRTIAL TRLS Page SD3 Via Malavolti, 36 • 41122 Modena •

SOLENOID OPERATED DIRECTIONAL CONTROLS

Page SD93

Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512 mail: [email protected] • www.tecnord.com

4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 mail: [email protected] • www.delta-power.com

WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken without independent study, evaluation, and testing for suitability.

W 2

0 /

2018

DIMENSIONS

ORDERING INFORMATIONApproximate Coil Weight: .42 lbs (.19 kg)

OPTIONS BODIESBuna Standard 00 Blank Without BodyViton Standard V0 N 1/4 NPTF Ports

Buna, Override, Detent 0M S #6 SAE PortsViton, Override, Detent VM

Buna, Screen A0Viton, Screen W0

Buna, Override, Nondetent B1Buna, Override, Nondetent V1 VOLTAGE

Buna, Screen, Override, Nondetent B3 06 6 VDCViton, Screen, Override, Nondetent V3 12 12 VDC

Buna, Screen, Override, Detent B4 24 24 VDCViton, Screen, Override, Detent V4 36 36 VDC

48 48 VDCNote: use screen only if flow 25 24 VAC

direction is from (1) to (2) 11 120 VAC22 220 VAC

“P” COIL TERMINATION 44 440 VAC(All DC Except as Noted)

IMMERSION PROOF “P” TYPEDL Double Lead SS Single Spade IA “I” Coil AMP Superseal - IntegralDT Deutsch on Leads DT04-2P DS Double Spade ID “I” Coil Deutsch - Integral DT04-2PML Metri-Pack on Leads HC DIN 43650 (Hirschmann) - (AC&DC) IJ “I” Coil AMP Jr. Timer - IntegralPL Packard on Leads CL Conduit Lead - (AC Only) IM “I” Coil Metri-Pack - IntegralWL Weatherpack on Leads DI Deutsch - Integral DT04-2P

PB-S2H – – – –

SEE COIL DATAFOR TERMINATIONS

.87 [22.1] HEX

3/4-16 UNF-2ATHREAD

2.90 [73.6]

1.12 [28.4]

2.13 [54.2]

1.25 [31.7]

1.54 [39.1]

.75 [19.1]

HEX NUT

STANDARD

MANUAL OVERRIDE

DE

LTA P

OW

ER

CO

SOLENOID OPERATED DIRECTIONAL CONTROLS

Page SD93

Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512 mail: [email protected] • www.tecnord.com

4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 mail: [email protected] • www.delta-power.com

WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken without independent study, evaluation, and testing for suitability.

W 1

8 /

2017

DIMENSIONS

ORDERING INFORMATIONApproximate Coil Weight: .42 lbs (.19 kg)

OPTIONS BODIESBuna Standard 00 Blank Without BodyViton Standard V0 N 1/4 NPTF Ports

Buna, Override, Detent 0M S #6 SAE PortsViton, Override, Detent VM

Buna, Screen A0Viton, Screen W0

Buna, Override, Nondetent B1Buna, Override, Nondetent V1 VOLTAGE

Buna, Screen, Override, Nondetent B3 06 6 VDCViton, Screen, Override, Nondetent V3 12 12 VDC

Buna, Screen, Override, Detent B4 24 24 VDCViton, Screen, Override, Detent V4 36 36 VDC

48 48 VDCNote: use screen only if flow 25 24 VAC

direction is from (1) to (2) 11 120 VAC22 220 VAC

“P” COIL TERMINATION 44 440 VAC(All DC Except as Noted)

IMMERSION PROOF “P” TYPEDL Double Lead SS Single Spade IA “I” Coil AMP Superseal - IntegralDT Deutsch on Leads DT04-2P DS Double Spade ID “I” Coil Deutsch - Integral DT04-2PML Metri-Pack on Leads HC DIN 43650 (Hirschmann) - (AC&DC) IJ “I” Coil AMP Jr. Timer - IntegralPL Packard on Leads CL Conduit Lead - (AC Only) IM “I” Coil Metri-Pack - IntegralWL Weatherpack on Leads DI Deutsch - Integral DT04-2P

PB-S2H – – – –

SEE COIL DATAFOR TERMINATIONS

.87 [22.1] HEX

3/4-16 UNF-2ATHREAD

2.90 [73.6]

1.12 [28.4]

2.13 [54.2]

1.25 [31.7]

1.54 [39.1]

.75 [19.1]

HEX NUT

STANDARD

MANUAL OVERRIDE

DE

LTA P

OW

ER

CO

SOLENOID OPERATED DIRECTIONAL CONTROLS Delta Power Company4484 Boeing Drive - Rockford, IL 61109

WARNING: The specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken without independent study, evaluation, and testing for suitability.

Phone: (815) 397-6628 Fax: (815) 397-2526 E-mail: [email protected]

DIMENSIONS

ORDERING INFORMATION PB-S2H - - - -

OPTIONS BODIES

Buna Standard 00 Blank Without Body Viton Standard V0 N 1/4 NPTF Ports

Buna, Override, Detent 0M S #6 SAE Ports Viton, Override, Detent VM

Buna, Screen A0 Viton, Screen W0 VOLTAGE

Buna, Override, Nondetent B1 06 6 VDC Viton. Override, Nondetent V1 12 12 VDC

Buna, Screen, Override, Nondetent B3 24 24 VDC Viton, Screen, Override, Nondetent V3 36 36 VDC

Buna, Screen, Override, Detent B4 48 48 VDC Viton, Screen, Override, Detent V4 25 24 VAC

11 120 VAC Note: Use screen only if flow direction

is from (1) to (2). 22 220 VAC 44 440 VAC

“P” COIL TERMINATION (All DC Except as Noted)

IMMERSION PROOF “P” TYPE DL Double Lead SS Single Spade IA “I” COIL AMP Superseal - Integral DT Deutsch on Leads DT04-2P DS Double Spade ID “I” COIL Deutsch – Integral DT04-2P ML Metri-Pack on Leads HC Din 43650 (Hirschmann) – (AC & DC) IJ “I” COIL AMP Jr. Timer – Integral PL Packard on Leads CL Conduit Lead – (AC Only) IM “I” COIL Metri-Pack – Integral WL Weatherpack on Leads DI Deutsch – Integral DT04-2P

Approximate Coil Weight: .42 lbs/.19 kg.

Page 109

Page 90: SOLENOID OPERATED DIRECTIONAL … 1000 38 69 7/8-14 DE-S2F SD18 2 WAY 2 POSITION NORMALLY CLOSED POPPET VALVES SLID PRATD DIRTIAL TRLS Page SD3 Via Malavolti, 36 • 41122 Modena •

SOLENOID OPERATED DIRECTIONAL CONTROLS

Page SD94

Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512 mail: [email protected] • www.tecnord.com

4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 mail: [email protected] • www.delta-power.com

WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken without independent study, evaluation, and testing for suitability.

W 20 / 2018

DE-S2H DIRECT ACTING SPOOL, 2 WAY NORMALLY OPEN

DESCRIPTION10 size, 7/8-14 thread, “Delta” series, solenoid operated, 2 way normally open, spool valve.

OPERATIONWhen de-energized the DE-S2H allows flow from (1) to (2) and (2) to (1). When energized the valve blocks flow from (1) to (2) and (2) to (1).OPERATION OF MANUAL OVERRIDE OPTION: to override, pull knob out. On the detented version, after pulling knob out twist 180 degrees and release. The valve will remain in that position.

FEATURES • Hardened parts for long life.• Efficient wet-armature construction.• Manual override option.• Industry common cavity.• Unitized, molded coil design.• Continuous duty rated solenoid.• Optional coil voltages and terminations.• Optional “I” Coil: Weatherproof, Thermal Shock, Immersion Safe.

Nominal Flow 8 GPM (30 LPM) from (1) to (2) 4 GPM (15 LPM) from (2) to (1)Rated Operating Pressure 3500 PSI (241 bar)Typical Internal Leakage (150 SSU) 5 cu in/min (82 ml/min)Viscosity Range 36 to 3000 SSU (3 to 647 cSt)Filtration ISO 18/16/13Media Operating Temp. Range -40° to 250°F (-40° to 120°C)Weight .26 lbs (.12 kg)Operating Fluid Media General Purpose Hydraulic FluidCartridge Torque Requirements 30 ft-lbs (40.6 Nm)Coil Nut Torque Requirements 4-6 ft-lbs (5.4-8.1 Nm)Cavity DELTA 2WCavity Tools Kit (form tool, reamer, tap) 40500000Seal Kit 21191202

Actual Test Data (Cartridge Only)

VALVE SPECIFICATIONS

0

50

100

150

200

250

0 2 6 84 100

5

Pre

ssur

e D

rop

(PS

I)

10

Flow (GPM)

15

0 10 20 30

Pre

ssur

e D

rop

(bar

)

Flow (LPM)

Port 1 to 2 (de-eng) Port 2 to 1 (de-eng)

For higher pressure systems see HE-S2H.

PERFORMANCE

HYDRAULIC SYMBOL

2

1

Page 91: SOLENOID OPERATED DIRECTIONAL … 1000 38 69 7/8-14 DE-S2F SD18 2 WAY 2 POSITION NORMALLY CLOSED POPPET VALVES SLID PRATD DIRTIAL TRLS Page SD3 Via Malavolti, 36 • 41122 Modena •

SOLENOID OPERATED DIRECTIONAL CONTROLS

Page SD95

Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512 mail: [email protected] • www.tecnord.com

4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 mail: [email protected] • www.delta-power.com

WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken without independent study, evaluation, and testing for suitability.

W 2

0 /

2018

DIMENSIONS

ORDERING INFORMATIONApproximate Coil Weight: .74 lbs (.33 kg)

OPTIONS BODIESBuna Standard 00 Blank Without BodyViton Standard V0 N 3/8 NPTF Ports

Buna, Override, Detent 0M S #8 SAE PortsViton, Override, Detent VM

Buna, Screen A0Viton, Screen W0

Buna, Override, Nondetent B1Buna, Override, Nondetent V1 VOLTAGE

Buna, Screen, Override, Nondetent B3 06 6 VDCViton, Screen, Override, Nondetent V3 12 12 VDC

Buna, Screen, Override, Detent B4 24 24 VDCViton, Screen, Override, Detent V4 36 36 VDC

48 48 VDCNote: use screen only if flow 25 24 VAC

direction is from (1) to (2) 11 120 VAC22 220 VAC

“D” COIL TERMINATION 44 440 VAC(All DC Except as Noted)

IMMERSION PROOF “D” TYPEDL Double Lead SS Single Spade IA “I” Coil AMP Superseal - IntegralDT Deutsch on Leads DT04-2P DS Double Spade ID “I” Coil Deutsch - Integral DT04-2PML Metri-Pack on Leads HC DIN 43650 (Hirschmann) - (AC&DC) IJ “I” Coil AMP Jr. Timer - IntegralPL Packard on Leads CL Conduit Lead - (AC Only) IM “I” Coil Metri-Pack - IntegralWL Weatherpack on Leads DI Deutsch - Integral DT04-2P

DE-S2H – – – –D

ELTA

PO

WE

R

.22 [5.6]

1.25 [31.7]

1.56 [39.6]

1.84 [46.6]

SEE COIL DATAFOR TERMINATIONS

.48 [12.2]

7/8-14 UNF 2ATHREAD

12-24 UNC 2ATHREAD

1.00 [25.4] HEX

MANUAL OVERRIDE

2.31 [58.8]

3.50 [88.9]

STANDARD

.75 [19.1]

HEX NUT

SOLENOID OPERATED DIRECTIONAL CONTROLS

Page SD95

Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512 mail: [email protected] • www.tecnord.com

4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 mail: [email protected] • www.delta-power.com

WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken without independent study, evaluation, and testing for suitability.

W 1

8 /

2017

DIMENSIONS

ORDERING INFORMATIONApproximate Coil Weight: .74 lbs (.33 kg)

OPTIONS BODIESBuna Standard 00 Blank Without BodyViton Standard V0 N 3/8 NPTF Ports

Buna, Override, Detent 0M S #8 SAE PortsViton, Override, Detent VM

Buna, Screen A0Viton, Screen W0

Buna, Override, Nondetent B1Buna, Override, Nondetent V1 VOLTAGE

Buna, Screen, Override, Nondetent B3 06 6 VDCViton, Screen, Override, Nondetent V3 12 12 VDC

Buna, Screen, Override, Detent B4 24 24 VDCViton, Screen, Override, Detent V4 36 36 VDC

48 48 VDCNote: use screen only if flow 25 24 VAC

direction is from (1) to (2) 11 120 VAC22 220 VAC

“D” COIL TERMINATION 44 440 VAC(All DC Except as Noted)

IMMERSION PROOF “D” TYPEDL Double Lead SS Single Spade IA “I” Coil AMP Superseal - IntegralDT Deutsch on Leads DT04-2P DS Double Spade ID “I” Coil Deutsch - Integral DT04-2PML Metri-Pack on Leads HC DIN 43650 (Hirschmann) - (AC&DC) IJ “I” Coil AMP Jr. Timer - IntegralPL Packard on Leads CL Conduit Lead - (AC Only) IM “I” Coil Metri-Pack - IntegralWL Weatherpack on Leads DI Deutsch - Integral DT04-2P

DE-S2H – – – –D

ELTA

PO

WE

R

.22 [5.6]

1.25 [31.7]

1.56 [39.6]

1.84 [46.6]

SEE COIL DATAFOR TERMINATIONS

.48 [12.2]

7/8-14 UNF 2ATHREAD

12-24 UNC 2ATHREAD

1.00 [25.4] HEX

MANUAL OVERRIDE

2.31 [58.8]

3.50 [88.9]

STANDARD

.75 [19.1]

HEX NUT

SOLENOID OPERATED DIRECTIONAL CONTROLS Delta Power Company4484 Boeing Drive - Rockford, IL 61109

WARNING: The specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken without independent study, evaluation, and testing for suitability.

Phone: (815) 397-6628 Fax: (815) 397-2526 E-mail: [email protected]

DIMENSIONS

2.35 [59.6]

1.25 [31.7]

.22 [5.6] 7/8-14 UNF 2 A

THREAD

1.00 [25.4] HEX

1.56 [39.6]

1.84 [46.6]

SEE COI L DATAFOR TERMIN ATIONS

DE

LTA PO

WE

R C

O.

3.35 [85.0]

.75 [19.1]

HEX NU T

MANUAL OVERRIDE

STANDARD 7/16-20 UNF 2 ATHREAD

.48 [12.2]

ORDERING INFORMATION DE-S2H - - - -

OPTIONS BODIES

Buna Standard 00 Blank Without Body Viton Standard V0 N 3/8 NPTF Ports Buna, Override 0M S #8 SAE Ports Viton, Override VM

Buna, Screen A0 Viton, Screen W0 VOLTAGE

Buna, Override, Non-detent B1 06 6 VDC Viton, Override, Non-detent V1 12 12 VDC

Buna, Screen, Override, Non-detent B3 24 24 VDC Buna, Screen, Override, Detent B4 36 36 VDC

Viton, Screen, Override, Non-detent V3 48 48 VDC Viton, Screen, Override, Detent V4 25 24 VAC

11 120 VAC 22 220 VAC Note: Use screen only if flow direction

is from (1) to (2). 44 440 VAC

“D” COIL TERMINATION (All DC Except as Noted)

IMMERSION PROOF “D” TYPE DL Double Lead SS Single Spade IA “I” Coil AMP Superseal - Integral DT Deutsch on Leads DT04-2P DS Double Spade ID “I” Coil Deutsch – Integral DT04-2P ML Metri-Pack on Leads HC DIN 43650 (Hirschman) – (AC & DC) IJ “I” Coil AMP Jr. Timer - Integral PL Packard on Leads CL Conduit Lead – (AC Only) IM “I” Coil Metri-Pack – Integral WL Weatherpack on Leads DI Deutsch – Integral DT04-2P

Approximate Coil Weight: .74 lbs/.33 kg.

Page 111

Page 92: SOLENOID OPERATED DIRECTIONAL … 1000 38 69 7/8-14 DE-S2F SD18 2 WAY 2 POSITION NORMALLY CLOSED POPPET VALVES SLID PRATD DIRTIAL TRLS Page SD3 Via Malavolti, 36 • 41122 Modena •

SOLENOID OPERATED DIRECTIONAL CONTROLS

Page SD96

Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512 mail: [email protected] • www.tecnord.com

4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 mail: [email protected] • www.delta-power.com

WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken without independent study, evaluation, and testing for suitability.

W 20 / 2018

HE-S2H DIRECT ACTING SPOOL, 2 WAY NORMALLY OPEN

DESCRIPTION“High Pressure” 10 size, 7/8-14 thread, “Delta” series, solenoid operated, 2 way normally open, spool valve.

OPERATIONWhen de-energized the HE-S2H allows flow from (1) to (2) and (2) to (1). When energized the valve blocks flow from (1) to (2) and (2) to (1).

FEATURES • Hardened parts for long life.• Efficient wet-armature construction.• Cartridges are voltage interchangeable.• Industry common cavity.• Unitized, molded coil design.• Continuous duty rated solenoid.• Optional coil voltages and terminations.• Optional “I” Coil: Weatherproof, Thermal Shock, Immersion Safe.

Nominal Flow 8 GPM (30 LPM) from (1) to (2) 4 GPM (15 LPM) from (2) to (1)Rated Operating Pressure 4000 PSI (276 bar)Typical Internal Leakage (150 SSU) 8 cu in/min (131 ml/min)Viscosity Range 36 to 3000 SSU (3 to 647 cSt)Filtration ISO 18/16/13Media Operating Temp. Range -40° to 250°F (-40° to 120°C)Weight .38 lbs (.17 kg)Operating Fluid Media General Purpose Hydraulic FluidCartridge Torque Requirements 35 ft-lbs (47.5 Nm)Coil Nut Torque Requirements 4-6 ft-lbs (5.4-8.1 Nm)Cavity DELTA 2WCavity Tools Kit (form tool, reamer, tap) 40500000Seal Kit 21191202

Actual Test Data (Cartridge Only)

VALVE SPECIFICATIONS

0

50

100

150

200

250

0

300

62 4 8 100

Flow (GPM)

5

10

15

20

0

Pre

ssur

e D

rop

(PS

I)

5 10 15 20 3025 35Flow (LPM)

Pre

ssur

e D

rop

(bar

)

Port 1 to 2 (de-eng) Port 2 to 1 (de-eng)

PERFORMANCE

HYDRAULIC SYMBOL Uses “L” Coils.

2

1

Page 93: SOLENOID OPERATED DIRECTIONAL … 1000 38 69 7/8-14 DE-S2F SD18 2 WAY 2 POSITION NORMALLY CLOSED POPPET VALVES SLID PRATD DIRTIAL TRLS Page SD3 Via Malavolti, 36 • 41122 Modena •

SOLENOID OPERATED DIRECTIONAL CONTROLS

Page SD97

Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512 mail: [email protected] • www.tecnord.com

4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 mail: [email protected] • www.delta-power.com

WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken without independent study, evaluation, and testing for suitability.

W 2

0 /

2018

Note: Aluminum, NOT durability rated for 4000 PSI. Consult factory for body options.

DIMENSIONS

ORDERING INFORMATIONApproximate Coil Weight: .68 lbs (.31 kg)

OPTIONS BODIESBuna Standard 00 Blank Without BodyViton Standard V0 N 3/8 NPTF Ports

S #8 SAE Ports

VOLTAGE06 6 VDC12 12 VDC24 24 VDC36 36 VDC48 48 VDC25 24 VAC11 120 VAC22 220 VAC

“L” COIL TERMINATION 44 440 VAC(All DC Except as Noted)

IMMERSION PROOF “L” TYPEDL Double Lead SS Single Spade IA “I” Coil AMP Superseal - IntegralDT Deutsch on Leads DT04-2P DS Double Spade ID “I” Coil Deutsch - Integral DT04-2PML Metri-Pack on Leads HC DIN 43650 (Hirschmann) - (AC&DC) IJ “I” Coil AMP Jr. Timer - IntegralPL Packard on Leads CL Conduit Lead - (AC Only) IM “I” Coil Metri-Pack - IntegralWL Weatherpack on Leads DI Deutsch - Integral DT04-2P

HE-S2H – – – –D

ELTA

PO

WE

R

1.83

[46.6]

.75 [19.1]

HEX NUT

1.25 [31.7]

2.66 [67.5]

3.91 [99.2]

.50 [12.7]

1.00 [24.5] HEX

7/8-14 UNF-2A TH'D

1.56 [39.6]

SOLENOID OPERATED DIRECTIONAL CONTROLS

Page SD97

Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512 mail: [email protected] • www.tecnord.com

4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 mail: [email protected] • www.delta-power.com

WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken without independent study, evaluation, and testing for suitability.

W 1

8 /

2017

Note: Aluminum, NOT durability rated for 4000 PSI. Consult factory for body options.

DIMENSIONS

ORDERING INFORMATIONApproximate Coil Weight: .68 lbs (.31 kg)

OPTIONS BODIESBuna Standard 00 Blank Without BodyViton Standard V0 N 3/8 NPTF Ports

S #8 SAE Ports

VOLTAGE06 6 VDC12 12 VDC24 24 VDC36 36 VDC48 48 VDC25 24 VAC11 120 VAC22 220 VAC

“L” COIL TERMINATION 44 440 VAC(All DC Except as Noted)

IMMERSION PROOF “L” TYPEDL Double Lead SS Single Spade IA “I” Coil AMP Superseal - IntegralDT Deutsch on Leads DT04-2P DS Double Spade ID “I” Coil Deutsch - Integral DT04-2PML Metri-Pack on Leads HC DIN 43650 (Hirschmann) - (AC&DC) IJ “I” Coil AMP Jr. Timer - IntegralPL Packard on Leads CL Conduit Lead - (AC Only) IM “I” Coil Metri-Pack - IntegralWL Weatherpack on Leads DI Deutsch - Integral DT04-2P

HE-S2H – – – –D

ELTA

PO

WE

R

1.83

[46.6]

.75 [19.1]

HEX NUT

1.25 [31.7]

2.66 [67.5]

3.91 [99.2]

.50 [12.7]

1.00 [24.5] HEX

7/8-14 UNF-2A TH'D

1.56 [39.6]

SOLENOID OPERATED DIRECTIONAL CONTROLS Delta Power Company4484 Boeing Drive - Rockford, IL 61109

WARNING: The specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken without independent study, evaluation, and testing for suitability.

Phone: (815) 397-6628 Fax: (815) 397-2526 E-mail: [email protected]

DIMENSIONS

ORDERING INFORMATION HE-S2H - - -

OPTIONS BODIES Note: Aluminum, NOT durability rated for

Buna Standard 00 Blank Without Body 4000 PSI. Consult factory options. Viton Standard V0 N 3/8 NPTF Ports

S #8 SAE Ports VOLTAGE 06 6 VDC

12 12 VDC 24 24 VDC

36 36 VDC 48 48 VAC 25 25 VAC 11 120 VAC 22 220 VAC 44 440 VAC

“L” - COIL TERMINATION (All DC Except as Noted)

IMMERSION PROOF “L” TYPE DL Double Lead SS Single Spade IA “I” Coil AMP Superseal - Integral DT Deutsch on Leads DT04-2P DS Double Spade ID “I” Coil Deutsch – Integral DT04-2P ML Metri-Pack on Leads HC DIN 43650 (Hirschman) – (AC & DC) IJ “I” Coil AMP Jr. Timer - Integral PL Packard on Leads CL Conduit Lead – (AC Only) IM “I” Coil Metri-Pack – Integral WL Weatherpack on Leads DI Deutsch – Integral DT04-2P

Approximate Coil Weight: .68 lbs. (.31 kg.)

Page 113

Page 94: SOLENOID OPERATED DIRECTIONAL … 1000 38 69 7/8-14 DE-S2F SD18 2 WAY 2 POSITION NORMALLY CLOSED POPPET VALVES SLID PRATD DIRTIAL TRLS Page SD3 Via Malavolti, 36 • 41122 Modena •

SOLENOID OPERATED DIRECTIONAL CONTROLS

Page SD98

W 20 / 2018

Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512 mail: [email protected] • www.tecnord.com

4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 mail: [email protected] • www.delta-power.com

WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken without independent study, evaluation, and testing for suitability.

3W2P SPOOL GPM PSI LPM BAR CAVITY MODEL PAGE

1 4000 4 276 5/8-18 UC-S3A SD100

3 3000 11 207 3/4-16 PP-S3A SD102

10 3000 38 207 7/8-14 DF-S3A SD104

10 4000 38 276 7/8-14 HF-S3A SD106

2.5 3000 9.5 207 3/4-16 PP-S3B SD108

8 3000 30 207 7/8-14 DF-S3B SD110

8 4000 30 276 7/8-14 HF-S3B SD112

15 5000 57 345 1 1/16-12 HU-S3E SD114

15 5000 57 345 1 1/16-12 HU-S3F SD116

3 3000 11 207 3/4-16 PP-S3X SD118

3 3000 11 207 3/4-16 PP-S3D

3 WAY 2 POSITION SPOOL VALVES

Page 95: SOLENOID OPERATED DIRECTIONAL … 1000 38 69 7/8-14 DE-S2F SD18 2 WAY 2 POSITION NORMALLY CLOSED POPPET VALVES SLID PRATD DIRTIAL TRLS Page SD3 Via Malavolti, 36 • 41122 Modena •

SOLENOID OPERATED DIRECTIONAL CONTROLS

Page SD99

W 2

0 /

2018

Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512 mail: [email protected] • www.tecnord.com

4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 mail: [email protected] • www.delta-power.com

WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken without independent study, evaluation, and testing for suitability.

3 WAY 2 POSITION SPOOL VALVES

The typical application for the S3A and S3E is to have the pump supply port blocked, with the work port vented to tank. In the examples shown, two valves are used to make a 4w3p motor center spool valve control function. The S3T is typically used for clutch and transmission applications. The MC-S3P is a low flow, low leakage, high pressure valve, used for pilot control of a larger main stage valve.The S3B, S3D, S3F and S3X valves are often used in selector applications, depending on flow, pressure and porting logic.

TYPICAL SCHEMATIC

SOLENOID OPERATED DIRECTIONAL CONTROLS

(3)

(1) (2)

(3)

(1) (2)

(3)

(1) (2)

(3)

(2) (1)a

(3)

(2)(1)

(3)

(1) (2)

(3)

(2) (1)

(3)

(2) (1)

(3)

(1)(2)

Page 96: SOLENOID OPERATED DIRECTIONAL … 1000 38 69 7/8-14 DE-S2F SD18 2 WAY 2 POSITION NORMALLY CLOSED POPPET VALVES SLID PRATD DIRTIAL TRLS Page SD3 Via Malavolti, 36 • 41122 Modena •

SOLENOID OPERATED DIRECTIONAL CONTROLS

Page SD100

Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512 mail: [email protected] • www.tecnord.com

4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 mail: [email protected] • www.delta-power.com

WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken without independent study, evaluation, and testing for suitability.

W 46 / 2018

UC-S3A DIRECT ACTING SPOOL, 3 WAY 2 POSITION

DESCRIPTION7 size, 5/8-18 thread, “Mini” series, solenoid operated, 3 way 2 position, spool valve.

OPERATIONWhen de-energized the UC-S3A blocks flow at (1) and allows flow from (3) to (2). When energized, the valve allows flow from (1) to (3) and blocks flow at (2).

FEATURES • Hardened parts for long life.• Efficient wet-armature construction.• Cartridges are voltage interchangeable.• Industry common cavity.• Unitized, molded coil design.• Continuous duty rated solenoid.• Optional coil voltages and terminations.

Nominal Flow 1 GPM (3.8 LPM) from (1) to (3) 2 GPM (7.6 LPM) from (3) to (2)Rated Operating Pressure 3500 PSI (241 bar)Typical Internal Leakage (150 SSU) 8 cu in/min (131 ml/min)Viscosity Range 36 to 3000 SSU (3 to 647 cSt)Filtration ISO 18/16/13Media Operating Temp. Range -40° to 250°F (-40° to 120°C)Weight .14 lbs (.06 kg)Operating Fluid Media General Purpose Hydraulic FluidCartridge Torque Requirements 15 ft-lbs (20.3 Nm)Coil Nut Torque Requirements 4-6 ft-lbs (5.4-8.1 Nm)Cavity MINI 3WCavity Form Tool (Finishing) 40500004Seal Kit 21191004

Actual Test Data (Cartridge Only)

VALVE SPECIFICATIONS

0

50

100

150

0

200

1 2Flow (GPM)

0

5

10

0 5

Pres

sure

Dro

p (P

SI)

Flow (LPM)

Pres

sure

Dro

p (B

AR)

Port 1 to 3 (eng) Port 3 to 2 (de-eng)

0

50

100

150

0

200

1 2Flow (GPM)

0

5

10

0 5

Pres

sure

Dro

p (P

SI)

Flow (LPM)

Pres

sure

Dro

p (B

AR)

Port 1 to 3 (eng) Port 3 to 2 (de-eng)

PERFORMANCE

HYDRAULIC SYMBOL

3

1

2

Uses “P” or “PI” type coils

Page 97: SOLENOID OPERATED DIRECTIONAL … 1000 38 69 7/8-14 DE-S2F SD18 2 WAY 2 POSITION NORMALLY CLOSED POPPET VALVES SLID PRATD DIRTIAL TRLS Page SD3 Via Malavolti, 36 • 41122 Modena •

SOLENOID OPERATED DIRECTIONAL CONTROLS

Page SD101

Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512 mail: [email protected] • www.tecnord.com

4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 mail: [email protected] • www.delta-power.com

WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken without independent study, evaluation, and testing for suitability.

W 4

6 /

2018

DIMENSIONS

ORDERING INFORMATIONApproximate Coil Weight: .30 lbs (.14 kg)

OPTIONS BODIESBuna Standard 00 Blank Without BodyViton Standard V0 N 1/4 NPTF Ports

S #6 SAE Ports

VOLTAGE06 6 VDC12 12 VDC24 24 VDC36 36 VDC48 48 VDC25 24 VAC11 120 VAC22 220 VAC

“P” COIL TERMINATION 44 440 VAC(All DC Except as Noted)

IMMERSION PROOF “P” TYPEDL Double Lead SS Single Spade IA “I” Coil AMP Superseal - IntegralDT Deutsch on Leads DT04-2P DS Double Spade ID “I” Coil Deutsch - Integral DT04-2PML Metri-Pack on Leads HC DIN 43650 (Hirschmann) - (AC&DC) IJ “I” Coil AMP Jr. Timer - IntegralPL Packard on Leads CL Conduit Lead - (AC Only) IM “I” Coil Metri-Pack - IntegralWL Weatherpack on Leads DI Deutsch - Integral DT04-2P

UC-S3A – – – –

Note: Aluminum, NOT durability rated for 4000 PSI. Consult factory for body options.

Page 98: SOLENOID OPERATED DIRECTIONAL … 1000 38 69 7/8-14 DE-S2F SD18 2 WAY 2 POSITION NORMALLY CLOSED POPPET VALVES SLID PRATD DIRTIAL TRLS Page SD3 Via Malavolti, 36 • 41122 Modena •

SOLENOID OPERATED DIRECTIONAL CONTROLS

Page SD102

Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512 mail: [email protected] • www.tecnord.com

4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 mail: [email protected] • www.delta-power.com

WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken without independent study, evaluation, and testing for suitability.

W 20 / 2018

PP-S3A DIRECT ACTING SPOOL, 3 WAY 2 POSITION

DESCRIPTION8 size, 3/4-16 thread, “Power” series, solenoid operated, 3 way 2 position, spool valve.

OPERATIONWhen de-energized the PP-S3A allows flow from (3) to (2) and blocks flow at port (1). When energized the valve allows flow from (1) to (3) and blocks flow at port (2).OPERATION OF MANUAL OVERRIDE OPTION: to override, pull knob out. On the detented version, after pulling knob out twist 180 degrees and release. The valve will remain in that position.

FEATURES • Hardened parts for long life.• Efficient wet-armature construction.• Cartridges are voltage interchangeable.• Manual override option.• Industry common cavity.• Unitized, molded coil design.• Continuous duty rated solenoid.• Optional coil voltages and terminations.• Optional “I” Coil: Weatherproof, Thermal Shock, Immersion Safe.

Nominal Flow 3 GPM (11 LPM)Rated Operating Pressure 3000 PSI (207 bar)Typical Internal Leakage (150 SSU) 5 cu in/min (82 ml/min)Viscosity Range 36 to 3000 SSU (3 to 647 cSt)Filtration ISO 18/16/13Media Operating Temp. Range -40° to 250°F (-40° to 120°C)Weight .23 lbs (.10 kg)Operating Fluid Media General Purpose Hydraulic FluidCartridge Torque Requirements 25 ft-lbs (34 Nm)Coil Nut Torque Requirements 4-6 ft-lbs (5.4-8.1 Nm)Cavity POWER 3WCavity Tools Kit (form tool, reamer, tap) 40500024Seal Kit 21191104

Actual Test Data (Cartridge Only)

VALVE SPECIFICATIONS

0

50

100

0 2

150

1 3Flow (GPM)

0

5

Pre

ssur

e D

rop

(PS

I)

10

0 5 10

Pre

ssur

e D

rop

(bar

)

Flow (LPM)

Port 1 to 3 (eng) Port 3 to 2 (de-eng)

Operational shift limit 3 GPM (11 LPM) from (1) to (3) at 3000 PSI (207 bar) and (3) to (2) with no load. For shifted flow performance consult chart.

PERFORMANCE

HYDRAULIC SYMBOL

3

1

2

Page 99: SOLENOID OPERATED DIRECTIONAL … 1000 38 69 7/8-14 DE-S2F SD18 2 WAY 2 POSITION NORMALLY CLOSED POPPET VALVES SLID PRATD DIRTIAL TRLS Page SD3 Via Malavolti, 36 • 41122 Modena •

SOLENOID OPERATED DIRECTIONAL CONTROLS

Page SD103

Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512 mail: [email protected] • www.tecnord.com

4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 mail: [email protected] • www.delta-power.com

WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken without independent study, evaluation, and testing for suitability.

W 2

0 /

2018

DIMENSIONS

ORDERING INFORMATIONApproximate Coil Weight: .42 lbs (.19 kg)

OPTIONS BODIESBuna Standard 00 Blank Without BodyViton Standard V0 N 1/4 NPTF Ports

Buna, Override, Detent 0M S #6 SAE PortsViton, Override, Detent VM

Buna, Screen A0Viton, Screen W0

Buna, Override, Nondetent B1Buna, Override, Nondetent V1 VOLTAGE

Buna, Screen, Override, Nondetent B3 06 6 VDCViton, Screen, Override, Nondetent V3 12 12 VDC

Buna, Screen, Override, Detent B4 24 24 VDCViton, Screen, Override, Detent V4 36 36 VDC

48 48 VDCNote: use screen only if flow 25 24 VAC

direction is from (1) to (2) 11 120 VAC22 220 VAC

“P” COIL TERMINATION 44 440 VAC(All DC Except as Noted)

IMMERSION PROOF “P” TYPEDL Double Lead SS Single Spade IA “I” Coil AMP Superseal - IntegralDT Deutsch on Leads DT04-2P DS Double Spade ID “I” Coil Deutsch - Integral DT04-2PML Metri-Pack on Leads HC DIN 43650 (Hirschmann) - (AC&DC) IJ “I” Coil AMP Jr. Timer - IntegralPL Packard on Leads CL Conduit Lead - (AC Only) IM “I” Coil Metri-Pack - IntegralWL Weatherpack on Leads DI Deutsch - Integral DT04-2P

PP-S3A – – – –

SEE COIL DATAFOR TERMINATIONS

.87 [22.1] HEX

3/4-16 UNF 2ATHREAD

2.90 [73.6] 2.13

[54.2]

1.25 [31.7]

1.54 [39.1]

.75 [19.1]

HEX NUT

1.62 [41.2]

DE

LTA P

OW

ER

CO

.

STANDARD

MANUAL OVERRIDE

DE

LT PO

WE

R C

O.

1.25 [31.8].63

[15.9]

2.10 [53.4]

.58 [14.8]

2.25 [57.2]

.25 [6.4]

1.17 [29.8]

2.50 [63.5]

2.25 [57.2]

1.75 [44.5]

1.13 [28.6]

.25 [6.4]

.28 [7.1] DIA.MTG. HOLES2X

#6 SAE PORTS 3X

BODY WEIGHT: .56 lbs (.25 kg)

Page 100: SOLENOID OPERATED DIRECTIONAL … 1000 38 69 7/8-14 DE-S2F SD18 2 WAY 2 POSITION NORMALLY CLOSED POPPET VALVES SLID PRATD DIRTIAL TRLS Page SD3 Via Malavolti, 36 • 41122 Modena •

SOLENOID OPERATED DIRECTIONAL CONTROLS

Page SD104

Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512 mail: [email protected] • www.tecnord.com

4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 mail: [email protected] • www.delta-power.com

WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken without independent study, evaluation, and testing for suitability.

W 20 / 2018

DF-S3A DIRECT ACTING SPOOL, 3 WAY 2 POSITION

DESCRIPTION10 size, 7/8-14 thread, “Delta” series, solenoid operated, 3 way 2 position, spool valve.

OPERATIONWhen de-energized the DF-S3A allows flow from (3) to (2) and blocks flow at port (1). When energized the valve allows flow from (1) to (3) and blocks flow at port (2).OPERATION OF MANUAL OVERRIDE OPTION: to override, pull knob out. On the detented version, after pulling knob out twist 180 degrees and release. The valve will remain in that position.

FEATURES • Hardened parts for long life.• Efficient wet-armature construction.• Cartridges are voltage interchangeable.• Manual override option.• Industry common cavity.• Unitized, molded coil design.• Continuous duty rated solenoid.• Optional coil voltages and terminations.• Optional “I” Coil: Weatherproof, Thermal Shock, Immersion Safe.

Nominal Flow 10 GPM (38 LPM)Rated Operating Pressure 3000 PSI (207 bar)Typical Internal Leakage (150 SSU) 5 cu in/min (82 ml/min)Viscosity Range 36 to 3000 SSU (3 to 647 cSt)Filtration ISO 18/16/13Media Operating Temp. Range -40° to 250°F (-40° to 120°C)Weight .28 lbs (.12 kg)Operating Fluid Media General Purpose Hydraulic FluidCartridge Torque Requirements 30 ft-lbs (40.6 Nm)Coil Nut Torque Requirements 4-6 ft-lbs (5.4-8.1 Nm)Cavity DELTA 3WCavity Tools Kit (form tool, reamer, tap) 40500001Seal Kit 21191210

Actual Test Data (Cartridge Only)

VALVE SPECIFICATIONS

Common lift/lower valve where load holding is not required. For higher pressures see HF-S3A.

PERFORMANCE

HYDRAULIC SYMBOL

3

1

2

0

50

100

150

200

0 2 64 8 10Flow (GPM)

Pre

ssur

e D

rop

(PS

I)

0

5

10

0 5 10 15 20 25 30 35

Pre

ssur

e D

rop

(bar

)

Flow (LPM)

Port 1 to 3 (eng) Port 3 to 2 (de-eng)

Page 101: SOLENOID OPERATED DIRECTIONAL … 1000 38 69 7/8-14 DE-S2F SD18 2 WAY 2 POSITION NORMALLY CLOSED POPPET VALVES SLID PRATD DIRTIAL TRLS Page SD3 Via Malavolti, 36 • 41122 Modena •

SOLENOID OPERATED DIRECTIONAL CONTROLS

Page SD105

Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512 mail: [email protected] • www.tecnord.com

4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 mail: [email protected] • www.delta-power.com

WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken without independent study, evaluation, and testing for suitability.

W 2

0 /

2018

DIMENSIONS

ORDERING INFORMATIONApproximate Coil Weight: .74 lbs (.33 kg)

OPTIONS BODIESBuna Standard 00 Blank Without BodyViton Standard V0 N 1/4 NPTF Ports

Buna, Override, Detent 0M S #6 SAE PortsViton, Override, Detent VM

Buna, Screen A0Viton, Screen W0

Buna, Override, Nondetent B1Buna, Override, Nondetent V1 VOLTAGE

Buna, Screen, Override, Nondetent B3 06 6 VDCViton, Screen, Override, Nondetent V3 12 12 VDC

Buna, Screen, Override, Detent B4 24 24 VDCViton, Screen, Override, Detent V4 36 36 VDC

48 48 VDCNote: use screen only if flow 25 24 VAC

direction is from (1) to (2) 11 120 VAC22 220 VAC

“D” COIL TERMINATION 44 440 VAC(All DC Except as Noted)

IMMERSION PROOF “D” TYPEDL Double Lead SS Single Spade IA “I” Coil AMP Superseal - IntegralDT Deutsch on Leads DT04-2P DS Double Spade ID “I” Coil Deutsch - Integral DT04-2PML Metri-Pack on Leads HC DIN 43650 (Hirschmann) - (AC&DC) IJ “I” Coil AMP Jr. Timer - IntegralPL Packard on Leads CL Conduit Lead - (AC Only) IM “I” Coil Metri-Pack - IntegralWL Weatherpack on Leads DI Deutsch - Integral DT04-2P

DF-S3A – – – –

DE

LTA P

OW

ER

CO

2.35 [59.6]

3.35 [85.1]

1.81 [46.0]

.22 [5.6]

7/8-14 UNF2A THREAD

1.00 [25.4] HEX

1.56 [39.6]

1.83 [46.6]

.75 [19.1]

HEX NUT

SEE COIL DATAFOR TERMINATIONS

STANDARD

MANUAL OVERRIDE

7/16-20 UNF2A THREAD

DE

LTA P

OW

ER

CO

.

2.28 [58.0]

2.50 [63.5]

1.37 [34.8]

.63 [15.9]

2.12 [53.8]

2.50 [63.5]

2.25 [57.2]

1.25 [31.8]

.13 [3.2]

1.56 [39.6]

1.50 [38.1]

.75 [19.1]

.28 [7.14] DIA.MTG. HOLES2X

#6 SAE PORTS3X

BODY WEIGHT: .76 lbs (.35 kg)

Page 102: SOLENOID OPERATED DIRECTIONAL … 1000 38 69 7/8-14 DE-S2F SD18 2 WAY 2 POSITION NORMALLY CLOSED POPPET VALVES SLID PRATD DIRTIAL TRLS Page SD3 Via Malavolti, 36 • 41122 Modena •

SOLENOID OPERATED DIRECTIONAL CONTROLS

Page SD106

Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512 mail: [email protected] • www.tecnord.com

4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 mail: [email protected] • www.delta-power.com

WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken without independent study, evaluation, and testing for suitability.

W 20 / 2018

HF-S3A DIRECT ACTING SPOOL, 3 WAY 2 POSITION

DESCRIPTION“High Pressure” 10 size, 7/8-14 thread, “Delta” series, solenoid operated, 3 way 2 position, spool valve.

OPERATIONWhen de-energized the HF-S3A blocks flow at port (1) and allows flow from (3) to (2). When energized the valve allows flow from (1) to (3) and blocks flow at port (2).

FEATURES • Hardened parts for long life.• Efficient wet-armature construction.• Cartridges are voltage interchangeable.• Industry common cavity.• Unitized, molded coil design.• Continuous duty rated solenoid.• Optional coil voltages and terminations.• Optional “I” Coil: Weatherproof, Thermal Shock, Immersion Safe.

Nominal Flow 10 GPM (38 LPM)Rated Operating Pressure 4000 PSI (276 bar)Typical Internal Leakage (150 SSU) 8 cu in/min (131 ml/min)Viscosity Range 36 to 3000 SSU (3 to 647 cSt)Filtration ISO 18/16/13Media Operating Temp. Range -40° to 250°F (-40° to 120°C)Weight .40 lbs (.18 kg)Operating Fluid Media General Purpose Hydraulic FluidCartridge Torque Requirements 30 ft-lbs (40.6 Nm)Coil Nut Torque Requirements 4-6 ft-lbs (5.4-8.1 Nm)Cavity DELTA 3WCavity Tools Kit (form tool, reamer, tap) 40500001Seal Kit 21191210

Actual Test Data (Cartridge Only)

VALVE SPECIFICATIONS

0

50

100

150

200

250

300

20 4 86 10 12

Flow (GPM)

0

5

10

15

Pre

ssur

e D

rop

(PS

I)

20

0 10 3020 40Flow (LPM)

Pre

ssur

e D

rop

(bar

)

Port 1 to 3 (eng) Port 3 to 2 (de-eng)

PERFORMANCE

HYDRAULIC SYMBOLUses “L” Coils.Pressure differential between ports should not exceed 3500 PSI.

3

1

2

Page 103: SOLENOID OPERATED DIRECTIONAL … 1000 38 69 7/8-14 DE-S2F SD18 2 WAY 2 POSITION NORMALLY CLOSED POPPET VALVES SLID PRATD DIRTIAL TRLS Page SD3 Via Malavolti, 36 • 41122 Modena •

SOLENOID OPERATED DIRECTIONAL CONTROLS

Page SD107

Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512 mail: [email protected] • www.tecnord.com

4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 mail: [email protected] • www.delta-power.com

WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken without independent study, evaluation, and testing for suitability.

W 2

0 /

2018

Note: Aluminum, NOT durability rated for 4000 PSI. Consult factory for body options.

DIMENSIONS

ORDERING INFORMATIONApproximate Coil Weight: .68 lbs (.31 kg)

OPTIONS BODIESBuna Standard 00 Blank Without BodyViton Standard V0 N 1/4 NPTF Ports

S #6 SAE Ports

VOLTAGE06 6 VDC12 12 VDC24 24 VDC36 36 VDC48 48 VDC25 24 VAC11 120 VAC22 220 VAC

“L” COIL TERMINATION 44 440 VAC(All DC Except as Noted)

IMMERSION PROOF “L” TYPEDL Double Lead SS Single Spade IA “I” Coil AMP Superseal - IntegralDT Deutsch on Leads DT04-2P DS Double Spade ID “I” Coil Deutsch - Integral DT04-2PML Metri-Pack on Leads HC DIN 43650 (Hirschmann) - (AC&DC) IJ “I” Coil AMP Jr. Timer - IntegralPL Packard on Leads CL Conduit Lead - (AC Only) IM “I” Coil Metri-Pack - IntegralWL Weatherpack on Leads DI Deutsch - Integral DT04-2P

HF-S3A – – – –

DE

LTA P

OW

ER

1.81 [46.0]

7/8-14 UNF-2A THREAD

1.00 [25.4] HEX

1.56 [39.6]

1.83 [46.6]

.75 [19.1]

HEX NUT

.50 [12.7]

2.60 [65.9]

SEE COIL DATAFOR TERMINATIONS

DE

LTA P

OW

ER

1.56 [39.6]

1.50 [38.1]

2.56 [65.1]

1.37 [34.8]

2.50 [63.5]

.63 [15.9]

2.12 [53.8]

2.50 [63.5]

2.25 [57.2]

.13 [3.2]

.281 [7.14] DIA 2X2X

#6 SAE PORTS 2X

BODY WEIGHT: .76 lbs (.35 kg)

.75 [19.1]

1.25 [31.8]

Page 104: SOLENOID OPERATED DIRECTIONAL … 1000 38 69 7/8-14 DE-S2F SD18 2 WAY 2 POSITION NORMALLY CLOSED POPPET VALVES SLID PRATD DIRTIAL TRLS Page SD3 Via Malavolti, 36 • 41122 Modena •

SOLENOID OPERATED DIRECTIONAL CONTROLS

Page SD110

Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512 mail: [email protected] • www.tecnord.com

4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 mail: [email protected] • www.delta-power.com

WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken without independent study, evaluation, and testing for suitability.

W 20 / 2018

DF-S3B DIRECT ACTING SPOOL, 3 WAY 2 POSITION, SELECTOR

DESCRIPTION10 size, 7/8-14 thread, “Delta” series, solenoid operated, 3 way 2 position, spool valve.

OPERATIONWhen de-energized the DF-S3B allows flow from (3) to (2) and blocks flow at port (1). When energized the valve allows flow from (3) to (1) and blocks flow at port (2).OPERATION OF MANUAL OVERRIDE OPTION: to override, pull knob out. On the detented version, after pulling knob out twist 180 degrees and release. The valve will remain in that position.

FEATURES • Hardened parts for long life.• Efficient wet-armature construction.• Cartridges are voltage interchangeable.• Manual override option.• Industry common cavity.• Unitized, molded coil design.• Continuous duty rated solenoid.• Optional coil voltages and terminations.• Optional “I” Coil: Weatherproof, Thermal Shock, Immersion Safe.

Nominal Flow 8 GPM (30 LPM)Rated Operating Pressure 3000 PSI (207 bar)Typical Internal Leakage (150 SSU) 5 cu in/min (82 ml/min)Viscosity Range 36 to 3000 SSU (3 to 647 cSt)Filtration ISO 18/16/13Media Operating Temp. Range -40° to 250°F (-40° to 120°C)Weight .28 lbs (.12 kg)Operating Fluid Media General Purpose Hydraulic FluidCartridge Torque Requirements 30 ft-lbs (40.6 Nm)Coil Nut Torque Requirements 4-6 ft-lbs (5.4-8.1 Nm)Cavity DELTA 3WCavity Tools Kit (form tool, reamer, tap) 40500001Seal Kit 21191210

Actual Test Data (Cartridge Only)

VALVE SPECIFICATIONSPERFORMANCE Actual Test Data (Cartridge Only)

0

25

50

75

100

0 2 4 6 8 10

Pre

ssur

e D

rop

(PS

I)

0

Flow (GPM)

5

0 5 10 2015 25 30 35

Pre

ssur

e D

rop

(bar

)

Flow (LPM)

Port 3 to 1 (eng) Port 3 to 2 (de-eng)

Trapped differentials above 1500 PSI (103 bar)from ports (2) to (1) can create shift issues near flow rating. Differentials to 3000 PSI from (1) to (2) are not an issue. For higher pressures consult HF-S3B.

PERFORMANCE

HYDRAULIC SYMBOL

3

1

2

Page 105: SOLENOID OPERATED DIRECTIONAL … 1000 38 69 7/8-14 DE-S2F SD18 2 WAY 2 POSITION NORMALLY CLOSED POPPET VALVES SLID PRATD DIRTIAL TRLS Page SD3 Via Malavolti, 36 • 41122 Modena •

SOLENOID OPERATED DIRECTIONAL CONTROLS

Page SD111

Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512 mail: [email protected] • www.tecnord.com

4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 mail: [email protected] • www.delta-power.com

WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken without independent study, evaluation, and testing for suitability.

W 2

0 /

2018

DIMENSIONS

ORDERING INFORMATIONApproximate Coil Weight: .74 lbs (.33 kg)

OPTIONS BODIESBuna Standard 00 Blank Without BodyViton Standard V0 N 1/4 NPTF Ports

Buna, Override, Detent 0M S #6 SAE PortsViton, Override, Detent VM

Buna, Screen A0Viton, Screen W0

Buna, Override, Nondetent B1Buna, Override, Nondetent V1 VOLTAGE

Buna, Screen, Override, Nondetent B3 06 6 VDCViton, Screen, Override, Nondetent V3 12 12 VDC

Buna, Screen, Override, Detent B4 24 24 VDCViton, Screen, Override, Detent V4 36 36 VDC

48 48 VDCNote: use screen only if flow 25 24 VAC

direction is from (1) to (2) 11 120 VAC22 220 VAC

“D” COIL TERMINATION 44 440 VAC(All DC Except as Noted)

IMMERSION PROOF “D” TYPEDL Double Lead SS Single Spade IA “I” Coil AMP Superseal - IntegralDT Deutsch on Leads DT04-2P DS Double Spade ID “I” Coil Deutsch - Integral DT04-2PML Metri-Pack on Leads HC DIN 43650 (Hirschmann) - (AC&DC) IJ “I” Coil AMP Jr. Timer - IntegralPL Packard on Leads CL Conduit Lead - (AC Only) IM “I” Coil Metri-Pack - IntegralWL Weatherpack on Leads DI Deutsch - Integral DT04-2P

DF-S3B – – – –

DE

LTA P

OW

ER

CO

2.35 [59.6]

3.35 [85.1]

1.81 [46.0]

.22 [5.6]

7/8-14 UNF2A THREAD

1.00 [25.4] HEX

1.56 [39.6]

1.83 [46.6]

.75 [19.1]

HEX NUT

SEE COIL DATAFOR TERMINATIONS

STANDARD

MANUAL OVERRIDE

7/16-20 UNF2A THREAD

DE

LTA P

OW

ER

CO

.

2.28 [58.0]

2.50 [63.5]

1.37 [34.8]

.63 [15.9]

2.12 [53.8]

2.50 [63.5]

2.25 [57.2]

1.25 [31.8]

.13 [3.2]

1.56 [39.6]

1.50 [38.1]

.75 [19.1]

.28 [7.14] DIA.MTG. HOLES2X

#6 SAE PORTS3X

BODY WEIGHT: .76 lbs (.35 kg)

Page 106: SOLENOID OPERATED DIRECTIONAL … 1000 38 69 7/8-14 DE-S2F SD18 2 WAY 2 POSITION NORMALLY CLOSED POPPET VALVES SLID PRATD DIRTIAL TRLS Page SD3 Via Malavolti, 36 • 41122 Modena •

SOLENOID OPERATED DIRECTIONAL CONTROLS

Page SD112

Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512 mail: [email protected] • www.tecnord.com

4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 mail: [email protected] • www.delta-power.com

WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken without independent study, evaluation, and testing for suitability.

W 20 / 2018

HF-S3B DIRECT ACTING SPOOL, 3 WAY 2 POSITION

DESCRIPTION“High Pressure” 10 size, 7/8-14 thread, “Delta” series, solenoid operated, 3 way 2 position, spool valve.

OPERATIONWhen de-energized the HF-S3A blocks flow at port (1) and allows flow from (3) to (2). When energized the valve allows flow from (1) to (3) and blocks flow at port (2).

FEATURES • Hardened parts for long life.• Efficient wet-armature construction.• Cartridges are voltage interchangeable.• Industry common cavity.• Unitized, molded coil design.• Continuous duty rated solenoid.• Optional coil voltages and terminations.• Optional “I” Coil: Weatherproof, Thermal Shock, Immersion Safe.

Nominal Flow 8 GPM (30 LPM) Rated Operating Pressure 4000 PSI (276 bar)Typical Internal Leakage (150 SSU) 8 cu in/min (131 ml/min)Viscosity Range 36 to 3000 SSU (3 to 647 cSt)Filtration ISO 18/16/13Media Operating Temp. Range -40° to 250°F (-40° to 120°C)Weight .40 lbs (.18 kg)Operating Fluid Media General Purpose Hydraulic FluidCartridge Torque Requirements 35 ft-lbs (47.5 Nm)Coil Nut Torque Requirements 4-6 ft-lbs (5.4-8.1 Nm)Cavity DELTA 3WCavity Tools Kit (form tool, reamer, tap) 40500001Seal Kit 21191210

Actual Test Data (Cartridge Only)

VALVE SPECIFICATIONS

0

50

100

150

200

250

300

0 5 10 15

Flow (GPM)

0

5

10

Pre

ssur

e D

rop

(PS

I)

15

20

0 5 1510 2520 3530 4540 5550Flow (LPM)

Pre

ssur

e D

rop

(bar

)

Port 3 to 1 (eng) Port 3 to 2 (de-eng)

PERFORMANCE

HYDRAULIC SYMBOL

3

1

2

Uses “L” Coils.Pressure differential between ports should not exceed 3500 PSI.

Page 107: SOLENOID OPERATED DIRECTIONAL … 1000 38 69 7/8-14 DE-S2F SD18 2 WAY 2 POSITION NORMALLY CLOSED POPPET VALVES SLID PRATD DIRTIAL TRLS Page SD3 Via Malavolti, 36 • 41122 Modena •

SOLENOID OPERATED DIRECTIONAL CONTROLS

Page SD113

Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512 mail: [email protected] • www.tecnord.com

4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 mail: [email protected] • www.delta-power.com

WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken without independent study, evaluation, and testing for suitability.

W 2

0 /

2018

Note: Aluminum, NOT durability rated for 4000 PSI. Consult factory for body options.

DIMENSIONS

ORDERING INFORMATIONApproximate Coil Weight: .68 lbs (.31 kg)

OPTIONS BODIESBuna Standard 00 Blank Without BodyViton Standard V0 N 1/4 NPTF Ports

S #6 SAE Ports

VOLTAGE06 6 VDC12 12 VDC24 24 VDC36 36 VDC48 48 VDC25 24 VAC11 120 VAC22 220 VAC

“L” COIL TERMINATION 44 440 VAC(All DC Except as Noted)

IMMERSION PROOF “L” TYPEDL Double Lead SS Single Spade IA “I” Coil AMP Superseal - IntegralDT Deutsch on Leads DT04-2P DS Double Spade ID “I” Coil Deutsch - Integral DT04-2PML Metri-Pack on Leads HC DIN 43650 (Hirschmann) - (AC&DC) IJ “I” Coil AMP Jr. Timer - IntegralPL Packard on Leads CL Conduit Lead - (AC Only) IM “I” Coil Metri-Pack - IntegralWL Weatherpack on Leads DI Deutsch - Integral DT04-2P

HF-S3B – – – –

DE

LTA P

OW

ER

1.81 [46.0]

7/8-14 UNF-2A THREAD

1.00 [25.4] HEX

1.56 [39.6]

1.83 [46.6]

.75 [19.1]

HEX NUT

.50 [12.7]

2.60 [65.9]

SEE COIL DATAFOR TERMINATIONS

DE

LTA P

OW

ER

1.56 [39.6]

1.50 [38.1]

2.56 [65.1]

1.37 [34.8]

2.50 [63.5]

.63 [15.9]

2.12 [53.8]

2.50 [63.5]

2.25 [57.2]

.13 [3.2]

.281 [7.14] DIA 2X2X

#6 SAE PORTS 2X

BODY WEIGHT: .76 lbs (.35 kg)

.75 [19.1]

1.25 [31.8]

Page 108: SOLENOID OPERATED DIRECTIONAL … 1000 38 69 7/8-14 DE-S2F SD18 2 WAY 2 POSITION NORMALLY CLOSED POPPET VALVES SLID PRATD DIRTIAL TRLS Page SD3 Via Malavolti, 36 • 41122 Modena •

SOLENOID OPERATED DIRECTIONAL CONTROLS

Page SD114

Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512 mail: [email protected] • www.tecnord.com

4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 mail: [email protected] • www.delta-power.com

WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken without independent study, evaluation, and testing for suitability.

W 20 / 2018

HU-S3E DIRECT ACTING SPOOL, 3 WAY 2 POSITION, HIGH PRESSURE

DESCRIPTION12 size, 1 1/16-12 thread, “Tecnord” series, solenoid operated, 3 way 2 position, spool valve.

OPERATIONWhen de-energized the HU-S3E allows flow from (2) to (1) and blocks flow at port (3). When energized the valve allows flow from (3) to (2) and blocks flow at port (1).

FEATURES • Hardened parts for long life.• Efficient wet-armature construction.• Cartridges are voltage interchangeable.• Industry common cavity.• Unitized, molded coil design.• Continuous duty rated solenoid.• Optional coil voltages and terminations.

Nominal Flow 15 GPM (57 LPM)Rated Operating Pressure 5000 PSI (345 bar)Typical Internal Leakage (150 SSU) 8 cu in/min @ 3000 PSIViscosity Range 36 to 3000 SSU (3 to 647 cSt)Filtration ISO 18/16/13Media Operating Temp. Range 40° to 250°F (-40° to 120°C)Weight 1.01 lbs (.46 kg)Operating Fluid Media General Purpose Hydraulic FluidCartridge Torque Requirements 70 ft-lbs (94.9 Nm)Coil Nut Torque Requirements 5-7 ft-lbs (6.8-9.5 Nm)Cavity TECNORD 3WCavity Tools Kit (form tool, reamer, tap) 40500034Seal Kit 21191305

Actual Test Data (Cartridge Only)

VALVE SPECIFICATIONS

Common usage is inlet at port (3). See HU-S3F for port (2) or port (1) inlet.

PERFORMANCE

HYDRAULIC SYMBOL

3

1

2

Page 109: SOLENOID OPERATED DIRECTIONAL … 1000 38 69 7/8-14 DE-S2F SD18 2 WAY 2 POSITION NORMALLY CLOSED POPPET VALVES SLID PRATD DIRTIAL TRLS Page SD3 Via Malavolti, 36 • 41122 Modena •

SOLENOID OPERATED DIRECTIONAL CONTROLS

Page SD115

Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512 mail: [email protected] • www.tecnord.com

4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 mail: [email protected] • www.delta-power.com

WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken without independent study, evaluation, and testing for suitability.

W 2

0 /

2018

DIMENSIONS

ORDERING INFORMATIONApproximate Coil Weight: .89 lbs (.41 kg)

OPTIONS BODIESBuna Standard 00 Blank Without BodyViton Standard V0 S #10 SAE Ports

VOLTAGE06 6 VDC

“T” COIL TERMINATION 12 12 VDC(All DC Except as Noted) 24 24 VDC

Double Lead DL 36 36 VDCDeutsch on Leads DT 48 48 VDC

Metri-Pack on Leads ML 25 24 VACPackard on Leads PL 11 120 VAC

Weatherpack on Leads WL 22 220 VACDouble Spade DS

DIN 43650 (Hirschmann) - (AC&DC) HC

HU-S3E – – – –

DELTA POWER CO.

2.88 [73.1]

3.82 [97.0]

1.80 [45.7]

1.00 [25.4]

HEX NUT

2.09 [53.2]

1.25 [31.8] HEX

1 1/16-12 UN2A THREAD

1.17 [29.6]

SEE COIL DATAFOR TERMINATIONS

DELTA POWER CO.

.88 [22.4]1.76

[44.7]

3.83 [97.4]

3.87 [98.3]

1.15 [29.2]

2.12 [54.0]

1.16 [29.4]

3.15 [80.0]

3.00 [76.2]

2.30 [58.4]

1.50 [38.1]

.35 [8.9]

BODY WEIGHT: 4.14 lbs (1.88 kg)

.41 [10.3] DIA.MTG. HOLES2X

#10 SAE PORTS3X

Page 110: SOLENOID OPERATED DIRECTIONAL … 1000 38 69 7/8-14 DE-S2F SD18 2 WAY 2 POSITION NORMALLY CLOSED POPPET VALVES SLID PRATD DIRTIAL TRLS Page SD3 Via Malavolti, 36 • 41122 Modena •

SOLENOID OPERATED DIRECTIONAL CONTROLS

Page SD116

Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512 mail: [email protected] • www.tecnord.com

4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 mail: [email protected] • www.delta-power.com

WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken without independent study, evaluation, and testing for suitability.

W 20 / 2018

HU-S3F DIRECT ACTING SPOOL, 3 WAY 2 POSITION, HIGH PRESSURE

DESCRIPTION12 size, 1 1/16-12 thread, “Tecnord” series, solenoid operated, 3 way 2 position, spool valve.

OPERATIONWhen de-energized the HU-S3F allows flow from (2) to (1) and blocks flow at port (3). When energized the valve allows flow from (2) to (3) and blocks flow at port (1).

FEATURES • Hardened parts for long life.• Efficient wet-armature construction.• Cartridges are voltage interchangeable.• Industry common cavity.• Unitized, molded coil design.• Continuous duty rated solenoid.• Optional coil voltages and terminations.

Nominal Flow 15 GPM (57 LPM)Rated Operating Pressure 5000 PSI (345 bar)Typical Internal Leakage (150 SSU) 8 cu in/min @ 3000 PSIViscosity Range 36 to 3000 SSU (3 to 647 cSt)Filtration ISO 18/16/13Media Operating Temp. Range -40° to 250°F (-40° to 120°C)Weight 1.01 lbs (.46 kg)Operating Fluid Media General Purpose Hydraulic FluidCartridge Torque Requirements 70 ft-lbs (94.9 Nm)Coil Nut Torque Requirements 5-7 ft-lbs (6.8-9.5 Nm) MaximumCavity TECNORD 3WCavity Tools Kit (form tool, reamer, tap) 40500034Seal Kit 21191305

Actual Test Data (Cartridge Only)

VALVE SPECIFICATIONS

Recommended usage is inlet at port (1) or (2).See HU-S3E for port (3) inlet.

PERFORMANCE

HYDRAULIC SYMBOL

3

1

2

Page 111: SOLENOID OPERATED DIRECTIONAL … 1000 38 69 7/8-14 DE-S2F SD18 2 WAY 2 POSITION NORMALLY CLOSED POPPET VALVES SLID PRATD DIRTIAL TRLS Page SD3 Via Malavolti, 36 • 41122 Modena •

SOLENOID OPERATED DIRECTIONAL CONTROLS

Page SD117

Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512 mail: [email protected] • www.tecnord.com

4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 mail: [email protected] • www.delta-power.com

WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken without independent study, evaluation, and testing for suitability.

W 2

0 /

2018

DIMENSIONS

ORDERING INFORMATIONApproximate Coil Weight: .89 lbs (.41 kg)

OPTIONS BODIESBuna Standard 00 Blank Without BodyViton Standard V0 S #10 SAE Ports

VOLTAGE06 6 VDC

“T” COIL TERMINATION 12 12 VDC(All DC Except as Noted) 24 24 VDC

Double Lead DL 36 36 VDCDeutsch on Leads DT 48 48 VDC

Metri-Pack on Leads ML 25 24 VACPackard on Leads PL 11 120 VAC

Weatherpack on Leads WL 22 220 VACDouble Spade DS

DIN 43650 (Hirschmann) - (AC&DC) HC

HU-S3F – – – –

DELTA POWER CO.

2.88 [73.1]

3.82 [97.0]

1.80 [45.7]

1.00 [25.4]

HEX NUT

2.09 [53.2]

1.25 [31.8] HEX

1 1/16-12 UN2A THREAD

1.17 [29.6]

SEE COIL DATAFOR TERMINATIONS

DELTA POWER CO.

.88 [22.4]1.76

[44.7]

3.83 [97.4]

3.87 [98.3]

1.15 [29.2]

2.12 [54.0]

1.16 [29.4]

3.15 [80.0]

3.00 [76.2]

2.30 [58.4]

1.50 [38.1]

.35 [8.9]

BODY WEIGHT: 4.14 lbs (1.88 kg)

.41 [10.3] DIA.MTG. HOLES2X

#10 SAE PORTS3X

Page 112: SOLENOID OPERATED DIRECTIONAL … 1000 38 69 7/8-14 DE-S2F SD18 2 WAY 2 POSITION NORMALLY CLOSED POPPET VALVES SLID PRATD DIRTIAL TRLS Page SD3 Via Malavolti, 36 • 41122 Modena •

SOLENOID OPERATED DIRECTIONAL CONTROLS

Page SD118

Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512 mail: [email protected] • www.tecnord.com

4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 mail: [email protected] • www.delta-power.com

WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken without independent study, evaluation, and testing for suitability.

W 20 / 2018

PP-S3X DIRECT ACTING SPOOL, 3 WAY 2 POSITION, SELECTOR

DESCRIPTION8 size, 3/4-16 thread, “Power” series, solenoid operated, 3 way 2 position, selector spool valve.

OPERATIONWhen de-energized the PP-S3X allows flow from (2) to (3) and blocks flow at port (1). When energized the valve allows flow from (2) to (1) and blocks flow at port (3).OPERATION OF MANUAL OVERRIDE OPTION: to override, pull knob out. On the detented version, after pulling knob out twist 180 degrees and release. The valve will remain in that position.

FEATURES • Hardened parts for long life.• Efficient wet-armature construction.• Cartridges are voltage interchangeable.• Manual override option.• Industry common cavity.• Unitized, molded coil design.• Continuous duty rated solenoid.• Optional coil voltages and terminations.• Optional “I” Coil: Weatherproof, Thermal Shock, Immersion Safe.

Nominal Flow 3 GPM (11 LPM)Rated Operating Pressure 3000 PSI (207 bar)Typical Internal Leakage (150 SSU) 5 cu in/min (82 ml/min)Viscosity Range 36 to 3000 SSU (3 to 647 cSt)Filtration ISO 18/16/13Media Operating Temp. Range -40° to 250°F (-40° to 120°C)Weight .23 lbs (.10 kg)Operating Fluid Media General Purpose Hydraulic FluidCartridge Torque Requirements 25 ft-lbs (34 Nm)Coil Nut Torque Requirements 4-6 ft-lbs (5.4-8.1 Nm)Cavity POWER 3WCavity Tools Kit (form tool, reamer, tap) 40500024Seal Kit 211911050

50

100

150

20 4 6Flow (GPM)

0

5

10

0 5 10 15 20

Pre

ssur

e D

rop

(PS

I)

Flow (LPM)

Pres

sure

Dro

p (b

ar)

Port 1 to 2 (eng) Port 2 to 3 (de-eng)

Actual Test Data (Cartridge Only)

VALVE SPECIFICATIONS

Operational shift limit 3 GPM (11 LPM) from port (2). Not recommended for port (3) inlet cavity. For shifted flow performance consult chart.

PERFORMANCE

HYDRAULIC SYMBOL

3

1

2

Page 113: SOLENOID OPERATED DIRECTIONAL … 1000 38 69 7/8-14 DE-S2F SD18 2 WAY 2 POSITION NORMALLY CLOSED POPPET VALVES SLID PRATD DIRTIAL TRLS Page SD3 Via Malavolti, 36 • 41122 Modena •

SOLENOID OPERATED DIRECTIONAL CONTROLS

Page SD119

Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512 mail: [email protected] • www.tecnord.com

4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 mail: [email protected] • www.delta-power.com

WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken without independent study, evaluation, and testing for suitability.

W 2

0 /

2018

DIMENSIONS

ORDERING INFORMATIONApproximate Coil Weight: .42 lbs (.19 kg)

OPTIONS BODIESBuna Standard 00 Blank Without BodyViton Standard V0 N 1/4 NPTF Ports

Buna, Override, Detent 0M S #6 SAE PortsViton, Override, Detent VM

Buna, Screen A0Viton, Screen W0

Buna, Override, Nondetent B1Buna, Override, Nondetent V1 VOLTAGE

Buna, Screen, Override, Nondetent B3 06 6 VDCViton, Screen, Override, Nondetent V3 12 12 VDC

Buna, Screen, Override, Detent B4 24 24 VDCViton, Screen, Override, Detent V4 36 36 VDC

48 48 VDCNote: use screen only if flow 25 24 VAC

direction is from (1) to (2) 11 120 VAC22 220 VAC

“P” COIL TERMINATION 44 440 VAC(All DC Except as Noted)

IMMERSION PROOF “P” TYPEDL Double Lead SS Single Spade IA “I” Coil AMP Superseal - IntegralDT Deutsch on Leads DT04-2P DS Double Spade ID “I” Coil Deutsch - Integral DT04-2PML Metri-Pack on Leads HC DIN 43650 (Hirschmann) - (AC&DC) IJ “I” Coil AMP Jr. Timer - IntegralPL Packard on Leads CL Conduit Lead - (AC Only) IM “I” Coil Metri-Pack - IntegralWL Weatherpack on Leads DI Deutsch - Integral DT04-2P

PP-S3X – – – –

SEE COIL DATAFOR TERMINATIONS

.87 [22.1] HEX

3/4-16 UNF 2ATHREAD

2.90 [73.6]

2.13 [54.2]

1.25 [31.7]

1.54 [39.1]

.75 [19.1]

HEX NUT

1.62 [41.2]

DE

LTA P

OW

ER

CO

.

STANDARD

MANUAL OVERRIDE

1.72 [43.6]

MINIMUM .406 DIAMETER PREDRILL 1.750 DEPTH REQUIRED.

SOLENOID OPERATED DIRECTIONAL CONTROLS

Page SD119

Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512 mail: [email protected] • www.tecnord.com

4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 mail: [email protected] • www.delta-power.com

WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken without independent study, evaluation, and testing for suitability.

W 1

8 /

2017

DIMENSIONS

ORDERING INFORMATIONApproximate Coil Weight: .42 lbs (.19 kg)

OPTIONS BODIESBuna Standard 00 Blank Without BodyViton Standard V0 N 1/4 NPTF Ports

Buna, Override, Detent 0M S #6 SAE PortsViton, Override, Detent VM

Buna, Screen A0Viton, Screen W0

Buna, Override, Nondetent B1Buna, Override, Nondetent V1 VOLTAGE

Buna, Screen, Override, Nondetent B3 06 6 VDCViton, Screen, Override, Nondetent V3 12 12 VDC

Buna, Screen, Override, Detent B4 24 24 VDCViton, Screen, Override, Detent V4 36 36 VDC

48 48 VDCNote: use screen only if flow 25 24 VAC

direction is from (1) to (2) 11 120 VAC22 220 VAC

“P” COIL TERMINATION 44 440 VAC(All DC Except as Noted)

IMMERSION PROOF “P” TYPEDL Double Lead SS Single Spade IA “I” Coil AMP Superseal - IntegralDT Deutsch on Leads DT04-2P DS Double Spade ID “I” Coil Deutsch - Integral DT04-2PML Metri-Pack on Leads HC DIN 43650 (Hirschmann) - (AC&DC) IJ “I” Coil AMP Jr. Timer - IntegralPL Packard on Leads CL Conduit Lead - (AC Only) IM “I” Coil Metri-Pack - IntegralWL Weatherpack on Leads DI Deutsch - Integral DT04-2P

PP-S3X – – – –

SEE COIL DATAFOR TERMINATIONS

.87 [22.1] HEX

3/4-16 UNF 2ATHREAD

2.90 [73.6]

2.13 [54.2]

1.25 [31.7]

1.54 [39.1]

.75 [19.1]

HEX NUT

1.62 [41.2]

DE

LTA P

OW

ER

CO

.

STANDARD

MANUAL OVERRIDE

1.72 [43.6]

MINIMUM .406 DIAMETER PREDRILL 1.750 DEPTH REQUIRED.

SOLENOID OPERATED DIRECTIONAL CONTROLS Delta Power Company4484 Boeing Drive - Rockford, IL 61109

WARNING: The specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken without independent study, evaluation, and testing for suitability.

Phone: (815) 397-6628 Fax: (815) 397-2526 E-mail: [email protected]

DIMENSIONS

ORDERING INFORMATION PP-S3X - - - -

OPTIONS BODIES

Buna Standard 00 Blank Without Body Viton Standard V0 N 1/4 NPTF Ports Buna, Override 0M S #6 SAE Ports Viton, Override VM

Buna, Screen A0 Viton, Screen W0 VOLTAGE

Buna, Override, Non-detent B1 06 6 VDC Viton, Override, Non-detent V1 12 12 VDC

Buna, Screen, Override, Non-detent B3 24 24 VDC Buna, Screen, Override, Detent B4 36 36 VDC

Viton, Screen, Override, Non-detent V3 48 48 VDC Viton, Screen, Override, Detent V4 25 24 VAC

11 120 VAC 22 220 VAC Note: Use screen only if flow direction

is from (1) to (2). 44 440 VAC

“P” COIL TERMINATION (All DC Except as Noted)

IMMERSION PROOF “P” TYPE DL Double Lead SS Single Spade IA “I” Coil AMP Superseal - Integral DT Deutsch on Leads DT04-2P DS Double Spade ID “I” Coil Deutsch – Integral DT04-2P ML Metri-Pack on Leads HC DIN 43650 (Hirschman) – (AC & DC) IJ “I” Coil AMP Jr. Timer - Integral PL Packard on Leads CL Conduit Lead – (AC Only) IM “I” Coil Metri-Pack – Integral WL Weatherpack on Leads DI Deutsch – Integral DT04-2P

Approximate Coil Weight: .42 lbs. (.19 kg.)

Page 145

Page 114: SOLENOID OPERATED DIRECTIONAL … 1000 38 69 7/8-14 DE-S2F SD18 2 WAY 2 POSITION NORMALLY CLOSED POPPET VALVES SLID PRATD DIRTIAL TRLS Page SD3 Via Malavolti, 36 • 41122 Modena •

SOLENOID OPERATED DIRECTIONAL CONTROLS

Page SD120

Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512 mail: [email protected] • www.tecnord.com

4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 mail: [email protected] • www.delta-power.com

WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken without independent study, evaluation, and testing for suitability.

W 20 / 2018

PP-S3D DIRECT ACTING SPOOL, 3 WAY 2 POSITION

DESCRIPTION8 size, 3/4-16 thread, “Power” series, solenoid operated, 3 way 2 position, spool valve.

OPERATIONWhen de-energized the PP-S3D allows flow from (2) to (1) and blocks flow at port (3). When energized the valve allows flow from (2) to (3) and blocks flow at port (1).OPERATION OF MANUAL OVERRIDE OPTION: to override, pull knob out. On the detented version, after pulling knob out twist 180 degrees and release. The valve will remain in that position.

FEATURES • Hardened parts for long life.• Efficient wet-armature construction.• Cartridges are voltage interchangeable.• Manual override option.• Industry common cavity.• Unitized, molded coil design.• Continuous duty rated solenoid.• Optional coil voltages and terminations.• Optional “I” Coil: Weatherproof, Thermal Shock, Immersion Safe.

Nominal Flow 3 GPM (11 LPM)Rated Operating Pressure 3000 PSI (207 bar)Typical Internal Leakage (150 SSU) 5 cu in/min (82 ml/min)Viscosity Range 36 to 3000 SSU (3 to 647 cSt)Filtration ISO 18/16/13Media Operating Temp. Range -40° to 250°F (-40° to 120°C)Weight .22 lbs (.10 kg)Operating Fluid Media General Purpose Hydraulic FluidCartridge Torque Requirements 25 ft-lbs (34 Nm)Coil Nut Torque Requirements 4-6 ft-lbs (5.4-8.1 Nm)Cavity POWER 3WCavity Tools Kit (form tool, reamer, tap) 40500024Seal Kit 21191105

Actual Test Data (Cartridge Only)

VALVE SPECIFICATIONS

0

50

100

150

200

0 2 6

250

4 8Flow (GPM)

0

Pre

ssur

e D

rop

(PS

I)

5

10

15

0 5 10 2015 25 30

Pre

ssur

e D

rop

(bar

)

Flow (LPM)

Port 2 to 1 (de-eng) Port 2 to 3 (eng)

Operational shift limit 3 GPM (11 LPM) from (2) or (3). Consult factory for flow in (1) that exceed 3 GPM. For shifted flow performance consult chart.

PERFORMANCE

HYDRAULIC SYMBOL

3

1

2

Page 115: SOLENOID OPERATED DIRECTIONAL … 1000 38 69 7/8-14 DE-S2F SD18 2 WAY 2 POSITION NORMALLY CLOSED POPPET VALVES SLID PRATD DIRTIAL TRLS Page SD3 Via Malavolti, 36 • 41122 Modena •

SOLENOID OPERATED DIRECTIONAL CONTROLS

Page SD121

Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512 mail: [email protected] • www.tecnord.com

4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 mail: [email protected] • www.delta-power.com

WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken without independent study, evaluation, and testing for suitability.

W 2

0 /

2018

DIMENSIONS

ORDERING INFORMATIONApproximate Coil Weight: .42 lbs (.19 kg)

OPTIONS BODIESBuna Standard 00 Blank Without BodyViton Standard V0 N 1/4 NPTF Ports

Buna, Override, Detent 0M S #6 SAE PortsViton, Override, Detent VM

Buna, Screen A0Viton, Screen W0

Buna, Override, Nondetent B1Buna, Override, Nondetent V1 VOLTAGE

Buna, Screen, Override, Nondetent B3 06 6 VDCViton, Screen, Override, Nondetent V3 12 12 VDC

Buna, Screen, Override, Detent B4 24 24 VDCViton, Screen, Override, Detent V4 36 36 VDC

48 48 VDCNote: use screen only if flow 25 24 VAC

direction is from (1) to (2) 11 120 VAC22 220 VAC

“P” COIL TERMINATION 44 440 VAC(All DC Except as Noted)

IMMERSION PROOF “P” TYPEDL Double Lead SS Single Spade IA “I” Coil AMP Superseal - IntegralDT Deutsch on Leads DT04-2P DS Double Spade ID “I” Coil Deutsch - Integral DT04-2PML Metri-Pack on Leads HC DIN 43650 (Hirschmann) - (AC&DC) IJ “I” Coil AMP Jr. Timer - IntegralPL Packard on Leads CL Conduit Lead - (AC Only) IM “I” Coil Metri-Pack - IntegralWL Weatherpack on Leads DI Deutsch - Integral DT04-2P

PP-S3D – – – –

SEE COIL DATAFOR TERMINATIONS

.87 [22.1] HEX

3/4-16 UNF 2ATHREAD

2.90 [73.6]

2.04 [51.7]

1.25 [31.7]

1.54 [39.1]

.75 [19.1]HEX NUT

1.62 [41.2]

DE

LTA P

OW

ER

CO

STANDARD

MANUAL OVERRIDE

SOLENOID OPERATED DIRECTIONAL CONTROLS

Page SD121

Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512 mail: [email protected] • www.tecnord.com

4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 mail: [email protected] • www.delta-power.com

WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken without independent study, evaluation, and testing for suitability.

W 1

8 /

2017

DIMENSIONS

ORDERING INFORMATIONApproximate Coil Weight: .42 lbs (.19 kg)

OPTIONS BODIESBuna Standard 00 Blank Without BodyViton Standard V0 N 1/4 NPTF Ports

Buna, Override, Detent 0M S #6 SAE PortsViton, Override, Detent VM

Buna, Screen A0Viton, Screen W0

Buna, Override, Nondetent B1Buna, Override, Nondetent V1 VOLTAGE

Buna, Screen, Override, Nondetent B3 06 6 VDCViton, Screen, Override, Nondetent V3 12 12 VDC

Buna, Screen, Override, Detent B4 24 24 VDCViton, Screen, Override, Detent V4 36 36 VDC

48 48 VDCNote: use screen only if flow 25 24 VAC

direction is from (1) to (2) 11 120 VAC22 220 VAC

“P” COIL TERMINATION 44 440 VAC(All DC Except as Noted)

IMMERSION PROOF “P” TYPEDL Double Lead SS Single Spade IA “I” Coil AMP Superseal - IntegralDT Deutsch on Leads DT04-2P DS Double Spade ID “I” Coil Deutsch - Integral DT04-2PML Metri-Pack on Leads HC DIN 43650 (Hirschmann) - (AC&DC) IJ “I” Coil AMP Jr. Timer - IntegralPL Packard on Leads CL Conduit Lead - (AC Only) IM “I” Coil Metri-Pack - IntegralWL Weatherpack on Leads DI Deutsch - Integral DT04-2P

PP-S3D – – – –

SEE COIL DATAFOR TERMINATIONS

.87 [22.1] HEX

3/4-16 UNF 2ATHREAD

2.90 [73.6]

2.04 [51.7]

1.25 [31.7]

1.54 [39.1]

.75 [19.1]HEX NUT

1.62 [41.2]

DE

LTA P

OW

ER

CO

STANDARD

MANUAL OVERRIDE

SOLENOID OPERATED DIRECTIONAL CONTROLS Delta Power Company4484 Boeing Drive - Rockford, IL 61109

WARNING: The specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken without independent study, evaluation, and testing for suitability.

Phone: (815) 397-6628 Fax: (815) 397-2526 E-mail: [email protected]

DIMENSIONS

SEE COIL DATAFOR TERMINATIONS

.87 [22.1] HEX

3/4-16 UNF 2ATHREAD

2.90 [73.6]

2.13 [54.2]

1.25 [31.7]

1.54 [39.1]

.75 [19.1]

HEX NUT

1.62 [41.2]

DE

LTA PO

WE

R C

O.

STANDARD

MANUAL OVERRIDE

ORDERING INFORMATION PP-S3D - - - -

OPTIONS BODIES

Buna Standard 00 Blank Without Body Viton Standard V0 N 1/4 NPTF Ports Buna, Override 0M S #6 SAE Ports Viton, Override VM

Buna, Screen A0 Viton, Screen W0 VOLTAGE

Buna, Override, Non-detent B1 06 6 VDC Viton, Override, Non-detent V1 12 12 VDC

Buna, Screen, Override, Non-detent B3 24 24 VDC Buna, Screen, Override, Detent B4 36 36 VDC

Viton, Screen, Override, Non-detent V3 48 48 VDC Viton, Screen, Override, Detent V4 25 24 VAC

11 120 VAC 22 220 VAC Note: Use screen only if flow direction

is from (1) to (2). 44 440 VAC

“P” COIL TERMINATION (All DC Except as Noted)

IMMERSION PROOF “P” TYPE DL Double Lead SS Single Spade IA “I” Coil AMP Superseal - Integral DT Deutsch on Leads DT04-2P DS Double Spade ID “I” Coil Deutsch – Integral DT04-2P ML Metri-Pack on Leads HC DIN 43650 (Hirschman) – (AC & DC) IJ “I” Coil AMP Jr. Timer - Integral PL Packard on Leads CL Conduit Lead – (AC Only) IM “I” Coil Metri-Pack – Integral WL Weatherpack on Leads DI Deutsch – Integral DT04-2P

Approximate Coil Weight: .42 lbs. (.19 kg.)

Page 133

Page 116: SOLENOID OPERATED DIRECTIONAL … 1000 38 69 7/8-14 DE-S2F SD18 2 WAY 2 POSITION NORMALLY CLOSED POPPET VALVES SLID PRATD DIRTIAL TRLS Page SD3 Via Malavolti, 36 • 41122 Modena •

SOLENOID OPERATED DIRECTIONAL CONTROLS

Page SD122

W 20 / 2018

Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512 mail: [email protected] • www.tecnord.com

4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 mail: [email protected] • www.delta-power.com

WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken without independent study, evaluation, and testing for suitability.

4W2P SPOOL GPM PSI LPM BAR CAVITY MODEL PAGE

1 4000 4 276 5/8-18 UD-S4A SD124

4 3000 15 207 3/4-16 PQ-S4A SD126

10 3500 38 241 7/8-14 DG-S4A SD128

10 4000 38 276 7/8-14 HG-S4A SD130

15 5000 57 345 1 1/16-12 HV-S4A SD132

1.5 4000 6 276 5/8-18 UD-S4B SD134

4 3000 15 207 3/4-16 PQ-S4B SD136

10 3000 38 207 7/8-14 DG-S4B SD138

10 4000 38 276 7/8-14 HG-S4B SD140

4 3000 15 207 3/4-16 PQ-S4C SD142

8 3000 30 207 7/8-14 DG-S4C SD144

8 4000 30 276 7/8-14 HG-S4C SD146

2.5 3000 9.5 207 3/4-16 PQ-S4D SD148

6 3000 23 207 7/8-14 DG-S4D SD150

8 4000 30 276 7/8-14 HG-S4D SD152

6 3000 23 207 7/8-14 DG-S4E SD154

8 4000 30 276 7/8-14 HG-S4E SD156

15 5000 57 345 1 1/16-12 HV-S4E SD158

6 3000 23 207 7/8-14 DG-S4F SD160

6 4000 23 276 7/8-14 HG-S4F SD162

4 WAY 2 POSITION SPOOL VALVES

Page 117: SOLENOID OPERATED DIRECTIONAL … 1000 38 69 7/8-14 DE-S2F SD18 2 WAY 2 POSITION NORMALLY CLOSED POPPET VALVES SLID PRATD DIRTIAL TRLS Page SD3 Via Malavolti, 36 • 41122 Modena •

SOLENOID OPERATED DIRECTIONAL CONTROLS

Page SD123

W 2

0 /

2018

Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512 mail: [email protected] • www.tecnord.com

4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 mail: [email protected] • www.delta-power.com

WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken without independent study, evaluation, and testing for suitability.

Typical application for the S4A, S4D, and S4F is directional motor or cylinder control.Typical application for the S4B is directional motor or cylinder control in a parallel circuit.Typical application for the S4C is directional motor or cylinder control in a series circuit.Typical application for the S4E is motor control in a series/parallel circuit.

TYPICAL SCHEMATIC

SOLENOID OPERATED DIRECTIONAL CONTROLS

(2) (4)

(3) (1)

(3)(1)

(4)( 2)

(3)(1)

(2)(4)

(3)( 1)

(2)( 4)

(3)( 1)

(2)( 4)

(2)

(1)

(4)

(3)

(3)( 1)

(2)( 4)

(3)( 1)

(2)( 4)

Page 118: SOLENOID OPERATED DIRECTIONAL … 1000 38 69 7/8-14 DE-S2F SD18 2 WAY 2 POSITION NORMALLY CLOSED POPPET VALVES SLID PRATD DIRTIAL TRLS Page SD3 Via Malavolti, 36 • 41122 Modena •

SOLENOID OPERATED DIRECTIONAL CONTROLS

Page SD126

Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512 mail: [email protected] • www.tecnord.com

4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 mail: [email protected] • www.delta-power.com

WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken without independent study, evaluation, and testing for suitability.

W 20 / 2018

PQ-S4A DIRECT ACTING SPOOL, 4 WAY 2 POSITION

DESCRIPTION8 size, 3/4-16 thread, “Power” series, solenoid operated, 4 way 2 position, spool valve.

OPERATIONWhen de-energized the PQ-S4A allows flow from (1) to (4) and from (2) to (3). When energized the valve allows flow from (2) to (1) and from (3) to (4).OPERATION OF MANUAL OVERRIDE OPTION: to override, pull knob out. On the detented version, after pulling knob out twist 180 degrees and release. The valve will remain in that position.

FEATURES • Hardened parts for long life.• Efficient wet-armature construction.• Cartridges are voltage interchangeable.• Manual override option.• Industry common cavity.• Unitized, molded coil design.• Continuous duty rated solenoid.• Optional coil voltages and terminations.• Optional “I” Coil: Weatherproof, Thermal Shock, Immersion Safe.

Nominal Flow 4 GPM (15 LPM)Rated Operating Pressure 3000 PSI (207 bar)Typical Internal Leakage (150 SSU) 5 cu in/min (82 ml/min)Viscosity Range 36 to 3000 SSU (3 to 647 cSt)Filtration ISO 18/16/13Media Operating Temp. Range -40° to 250°F (-40° to 120°C)Weight .24 lbs (.11 kg)Operating Fluid Media General Purpose Hydraulic FluidCartridge Torque Requirements 25 ft-lbs (34 Nm)Coil Nut Torque Requirements 4-6 ft-lbs (5.4-8.1 Nm)Cavity POWER 4WCavity Tools Kit (form tool, reamer, tap) 40500029Seal Kit 21191108

0

50

100

150

200

20 1 3 4 5Flow (GPM)

0

5

10

0 5 10 15

Pre

ssur

e D

rop

(PS

I)

Flow (LPM)

Pre

ssur

e D

rop

(bar

)

Port 2 to 1 (eng) Port 3 to 4 (eng)

0

50

100

150

200

250

300

0 1 2 3 4 5Flow (GPM)

0

5

10

15

Pre

ssur

e D

rop

(PS

I)

20

0 5 10 15Flow (LPM)

Pre

ssur

e D

rop

(bar

)

Port 1 to 4 (de-eng) Port 2 to 3 (de-eng)

Actual Test Data (Cartridge Only)

PERFORMANCE HYDRAULIC SYMBOL

VALVE SPECIFICATIONS

Modes of shift operation to 6 GPM, Consult Factory.

4

1

2

3

Page 119: SOLENOID OPERATED DIRECTIONAL … 1000 38 69 7/8-14 DE-S2F SD18 2 WAY 2 POSITION NORMALLY CLOSED POPPET VALVES SLID PRATD DIRTIAL TRLS Page SD3 Via Malavolti, 36 • 41122 Modena •

SOLENOID OPERATED DIRECTIONAL CONTROLS

Page SD127

Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512 mail: [email protected] • www.tecnord.com

4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 mail: [email protected] • www.delta-power.com

WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken without independent study, evaluation, and testing for suitability.

W 2

0 /

2018

DIMENSIONS

ORDERING INFORMATIONApproximate Coil Weight: .42 lbs (.19 kg)

OPTIONS BODIESBuna Standard 00 Blank Without BodyViton Standard V0 N 1/4 NPTF Ports

Buna, Override, Detent 0M S #6 SAE PortsViton, Override, Detent VM

Buna, Override, Nondetent B1Buna, Override, Nondetent V1

VOLTAGE06 6 VDC12 12 VDC24 24 VDC36 36 VDC48 48 VDC25 24 VAC11 120 VAC22 220 VAC

“P” COIL TERMINATION 44 440 VAC(All DC Except as Noted)

IMMERSION PROOF “P” TYPEDL Double Lead SS Single Spade IA “I” Coil AMP Superseal - IntegralDT Deutsch on Leads DT04-2P DS Double Spade ID “I” Coil Deutsch - Integral DT04-2PML Metri-Pack on Leads HC DIN 43650 (Hirschmann) - (AC&DC) IJ “I” Coil AMP Jr. Timer - IntegralPL Packard on Leads CL Conduit Lead - (AC Only) IM “I” Coil Metri-Pack - IntegralWL Weatherpack on Leads DI Deutsch - Integral DT04-2P

PQ-S4A – – – –D

ELTA

PO

WE

R

2.89 [73.5] 2.13

[54.2]

2.11 [53.6]

.25 [6.3]

3/4-16 UNF2A THREAD

1.25 [31.7]

1.54 [39.1]

.86 [22.2] HEX

MANUAL OVERRIDE

STANDARD

.75 [19.1]

HEX NUT

SEE COILDATA FOR TERMINATIONS

DE

LTA P

OW

ER

1.25 [31.8]

.63 [15.9]

2.10 [53.4]

.59 [15.1]

1.72 [43.7]

2.75 [69.9]

.25 [6.4]

1.16 [29.4]

3.00 [76.2]

2.25 [57.2]

1.75 [44.5]

1.13 [28.6]

.25 [6.4]

.28 [7.13] DIA.MTG. HOLES2X

#6 SAE PORTS4X

BODY WEIGHT: .67 lbs (.30 kg)

Page 120: SOLENOID OPERATED DIRECTIONAL … 1000 38 69 7/8-14 DE-S2F SD18 2 WAY 2 POSITION NORMALLY CLOSED POPPET VALVES SLID PRATD DIRTIAL TRLS Page SD3 Via Malavolti, 36 • 41122 Modena •

SOLENOID OPERATED DIRECTIONAL CONTROLS

Page SD128

Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512 mail: [email protected] • www.tecnord.com

4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 mail: [email protected] • www.delta-power.com

WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken without independent study, evaluation, and testing for suitability.

W 20 / 2018

DG-S4A DIRECT ACTING SPOOL, 4 WAY 2 POSITION

DESCRIPTION10 size, 7/8-14 thread, “Delta” series, solenoid operated, 4 way 2 position, side flow spool valve.

OPERATIONWhen de-energized the DG-S4A allows flow between (1) to (4) and (2) to (3). When energized the valve allows flow between (2) to (1) and (3) to (4).OPERATION OF MANUAL OVERRIDE OPTION: to override, pull knob out. On the detented version, after pulling knob out twist 180 degrees and release. The valve will remain in that position..

FEATURES • Hardened parts for long life.• Efficient wet-armature construction.• Cartridges are voltage interchangeable.• Manual override option.• Industry common cavity.• Unitized, molded coil design.• Continuous duty rated solenoid.• Optional coil voltages and terminations.• Optional “I” Coil: Weatherproof, Thermal Shock, Immersion Safe.

Nominal Flow 10 GPM (38 LPM)Rated Operating Pressure 3500 PSI (241 bar) per pathTypical Internal Leakage (150 SSU) 5 cu in/min (82 ml/min)Viscosity Range 36 to 3000 SSU (3 to 647 cSt)Filtration ISO 18/16/13Media Operating Temp. Range -40° to 250°F (-40° to 120°C)Weight .32 lbs (.15 kg)Operating Fluid Media General Purpose Hydraulic FluidCartridge Torque Requirements 30 ft-lbs (40.6 Nm)Coil Nut Torque Requirements 4-6 ft-lbs (5.4-8.1 Nm)Cavity DELTA 4WCavity Tools Kit (form tool, reamer, tap) 40500002Seal Kit 21191214

0

50

100

150

200

0 2 4 6 8 10Flow (GPM)

0

5

10

0 5

Pres

sure

Dro

p (P

SI)

10 15 20 25 30 35

0 5 10 15 20 25 30 35

Flow (LPM)

Pres

sure

Dro

p (b

ar)

Port 2 to 1 (eng) Port 3 to 4 (eng)

0

50

100

0

150

2 4 6 8 10

Flow (GPM)

0

5

10

Pres

sure

Dro

p (P

SI)

Pres

sure

Dro

p (b

ar)

Flow (LPM)

Port 1 to 4 (de-eng) Port 2 to 3 (de-eng)

Actual Test Data (Cartridge Only)

PERFORMANCE HYDRAULIC SYMBOL

VALVE SPECIFICATIONS

For higher pressures see HG-S4A.

4

1

2

3

Page 121: SOLENOID OPERATED DIRECTIONAL … 1000 38 69 7/8-14 DE-S2F SD18 2 WAY 2 POSITION NORMALLY CLOSED POPPET VALVES SLID PRATD DIRTIAL TRLS Page SD3 Via Malavolti, 36 • 41122 Modena •

SOLENOID OPERATED DIRECTIONAL CONTROLS

Page SD129

Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512 mail: [email protected] • www.tecnord.com

4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 mail: [email protected] • www.delta-power.com

WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken without independent study, evaluation, and testing for suitability.

W 2

0 /

2018

For higher pressures see HG-S4A.

DIMENSIONS

ORDERING INFORMATIONApproximate Coil Weight: .74 lbs (.33 kg)

OPTIONS BODIESBuna Standard 00 Blank Without BodyViton Standard V0 N 1/4 NPTF Ports

Buna, Override, Detent 0M S #6 SAE PortsViton, Override, Detent VM

Buna, Override, Non-detent B1Viton, Override, Non-detent V1 VOLTAGE

06 6 VDC12 12 VDC24 24 VDC36 36 VDC48 48 VDC25 24 VAC11 120 VAC22 220 VAC44 440 VAC

“D” COIL TERMINATION(All DC Except as Noted)

IMMERSION PROOF “D” TYPEDL Double Lead SS Single Spade IA “I” Coil AMP Superseal - IntegralDT Deutsch on Leads DT04-2P DS Double Spade ID “I” Coil - Deutsch - Integral DT04-2PML Metri-Pack on Leads HC DIN 43650 (Hirschmann) - (AC&DC) IJ “I” Coil AMP Jr. Timer - IntegralPL Packard on Leads CL Conduit Lead - (AC Only) IM “I” Coil - Metri-Pack - IntegralWL Weatherpack on Leads DI Deutsch - Integral DT04-2P

DG-S4A – – – – Approximate Coil Weight: .74 lbs (.33 kg)

DE

LTA PO

WE

R

1.56 [39.6]

1.83 [46.6]

.75 [19.1]

HEX NUT

3.35 [85.1] 2.31

[58.8]

2.44 [61.9]

.22 [5.6]

1.00 [25.4] HEX

7/8-14 UNF-2A

7/16-20 UNF-2ATHREAD

MANUAL OVERRIDE

STANDARD

SEE COILDATA FORTERMINATIONS

DE

LTA P

OW

ER

1.56 [39.6]

1.50 [38.1]

.81 [20.6]

2.27 [57.8]

.63 [15.9]

2.00 [50.8]

3.25 [82.6]

1.38 [34.9]

2.88 [73.0]

2.50 [63.5]

2.25 [57.2]

1.25 [31.8]

.13 [3.2]

.28 [7.1] DIA.MTG. SLOTS2X

#6 SAE PORTS4X

BODY WEIGHT: .99 lbs (.45 kg)

Page 122: SOLENOID OPERATED DIRECTIONAL … 1000 38 69 7/8-14 DE-S2F SD18 2 WAY 2 POSITION NORMALLY CLOSED POPPET VALVES SLID PRATD DIRTIAL TRLS Page SD3 Via Malavolti, 36 • 41122 Modena •

SOLENOID OPERATED DIRECTIONAL CONTROLS

Page SD130

Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512 mail: [email protected] • www.tecnord.com

4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 mail: [email protected] • www.delta-power.com

WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken without independent study, evaluation, and testing for suitability.

W 20 / 2018

HG-S4A DIRECT ACTING SPOOL, 4 WAY 2 POSITION, CRISS CROSS

DESCRIPTION“High Pressure” 10 size, 7/8-14 thread, “Delta” series, 4 way 2 position, side flow spool valve.

OPERATIONWhen de-energized the HG-S4A allows flow from (1) to (4) and from (2) to (3). When energized the valve allows flow from (2) to (1) and from (3) to (4).

FEATURES • Hardened parts for long life.• Efficient wet-armature construction.• Cartridges are voltage interchangeable.• Industry common cavity.• Unitized, molded coil design.• Continuous duty rated solenoid.• Optional coil voltages and terminations.• Optional “I” Coil: Weatherproof, Thermal Shock, Immersion Safe.

Nominal Flow 10 GPM (38 LPM) Rated Operating Pressure 4000 PSI (276 bar)Typical Internal Leakage (150 SSU) 10 cu in/min (164 ml/min) per pathViscosity Range 36 to 3000 SSU (3 to 647 cSt)Filtration ISO 18/16/13Media Operating Temp. Range -40° to 250°F (-40° to 120°C)Weight .44 lbs (.20 kg)Operating Fluid Media General Purpose Hydraulic FluidCartridge Torque Requirements 30 ft-lbs (40.6 Nm)Coil Nut Torque Requirements 4-6 ft-lbs (5.4-8.1 Nm)Cavity DELTA 4WCavity Tools Kit (form tool, reamer, tap) 40500002Seal Kit 21191214

0

50

100

150

6 820

200

4 10Flow (GPM)

0

5

10

0 5 10 15 20

Pres

sure

Dro

p (P

SI)

25 3530

0 5 10 15 20 25 3530

Flow (LPM)

Pres

sure

Dro

p (b

ar)

Port 2 to 1 (eng) Port 3 to 4 (eng)

0

50

100

0 2

150

64 8 10Flow (GPM)

0

5

10

Pres

sure

Dro

p (P

SI)

Flow (L PM)

Pres

sure

Dro

p (b

ar)

Port 1 to 4 (de-eng) Port 2 to 3 (de-eng)

Actual Test Data (Cartridge Only)

PERFORMANCE HYDRAULIC SYMBOL

VALVE SPECIFICATIONS

Uses “L” Coils.Pressure differential between ports should not exceed 3000 PSI.

4

1

2

3

Page 123: SOLENOID OPERATED DIRECTIONAL … 1000 38 69 7/8-14 DE-S2F SD18 2 WAY 2 POSITION NORMALLY CLOSED POPPET VALVES SLID PRATD DIRTIAL TRLS Page SD3 Via Malavolti, 36 • 41122 Modena •

SOLENOID OPERATED DIRECTIONAL CONTROLS

Page SD131

Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512 mail: [email protected] • www.tecnord.com

4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 mail: [email protected] • www.delta-power.com

WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken without independent study, evaluation, and testing for suitability.

W 2

0 /

2018

DIMENSIONS

ORDERING INFORMATIONApproximate Coil Weight: .68 lbs (.31 kg)

OPTIONS BODIESBuna Standard 00 Blank Without BodyViton Standard V0 N 1/4 NPTF Ports

S #6 SAE Ports

VOLTAGE06 6 VDC12 12 VDC24 24 VDC36 36 VDC48 48 VDC25 24 VAC11 120 VAC22 220 VAC

“L” COIL TERMINATION 44 440 VAC(All DC Except as Noted)

IMMERSION PROOF “L” TYPEDL Double Lead SS Single Spade IA “I” Coil AMP Superseal - IntegralDT Deutsch on Leads DT04-2P DS Double Spade ID “I” Coil Deutsch - Integral DT04-2PML Metri-Pack on Leads HC DIN 43650 (Hirschmann) - (AC&DC) IJ “I” Coil AMP Jr. Timer - IntegralPL Packard on Leads CL Conduit Lead - (AC Only) IM “I” Coil Metri-Pack - IntegralWL Weatherpack on Leads DI Deutsch - Integral DT04-2P

HG-S4A – – – –

Note: Aluminum, NOT durability rated for 4000 PSI. Consult factory for body options.

DE

LTA P

OW

ER

1.56 [39.6]

1.83 [46.6]

.75 [19.1]

HEX NUT

2.63 [66.8]

.50 [12.7]

2.44 [61.9]

7/8-14 UNF-2A THREAD

1.00 [25.4] HEX

SEE COILDATA FORTERMINATIONS

DE

LTA P

OW

ER

1.56 [39.6]

1.50 [38.1]

.81 [20.6]

2.59 [65.7]

.63 [15.9]

2.00 [50.8]

1.38 [34.9]

2.88 [73.0]

3.25 [82.6]

2.50 [63.5]

2.25 [57.2]

1.25 [31.8]

.13 [3.2]

.281 [7.14] DIA2X

#6 SAE PORTS4X

BODY WEIGHT: .99 lbs (.45 kg)

Page 124: SOLENOID OPERATED DIRECTIONAL … 1000 38 69 7/8-14 DE-S2F SD18 2 WAY 2 POSITION NORMALLY CLOSED POPPET VALVES SLID PRATD DIRTIAL TRLS Page SD3 Via Malavolti, 36 • 41122 Modena •

SOLENOID OPERATED DIRECTIONAL CONTROLS

Page SD132

Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512 mail: [email protected] • www.tecnord.com

4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 mail: [email protected] • www.delta-power.com

WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken without independent study, evaluation, and testing for suitability.

W 20 / 2018

HV-S4A DIRECT ACTING SPOOL, 4 WAY 2 POSITION, CRISS CROSS

DESCRIPTION“High pressure” 12 size, 1 1/16-12 thread, “Tecnord” series, solenoid operated, 4 way 2 position, criss cross side flow spool valve.

OPERATIONWhen de-energized the HV-S4A allows flow from (1) to (4) and from (2) to (3). When energized the valve allows flow from (2) to (1) and from (3) to (4).

FEATURES • Hardened parts for long life.• Efficient wet-armature construction.• Cartridges are voltage interchangeable.• Industry common cavity.• Unitized, molded coil design.• Continuous duty rated solenoid.• Optional coil voltages and terminations.

Nominal Flow 15 GPM (57 LPM)Rated Operating Pressure 5000 PSI (345 bar)Typical Internal Leakage (150 SSU) 8 cu in/min (131 ml/min) per pathViscosity Range 36 to 3000 SSU (3 to 647 cSt)Filtration ISO 18/16/13Media Operating Temp. Range 40° to 250°F (-40° to 120°C)Weight 1.07 lbs (.48 kg)Operating Fluid Media General Purpose Hydraulic FluidCartridge Torque Requirements 70 ft-lbs (94.9 Nm)Coil Nut Torque Requirements 5-7 ft-lbs (6.8-9.5 Nm)Cavity TECNORD 4WCavity Tools Kit (form tool, reamer, tap) 40500035Seal Kit 21191309

Actual Test Data (Cartridge Only)

VALVE SPECIFICATIONSPERFORMANCE

HYDRAULIC SYMBOL

4

1

2

3

Page 125: SOLENOID OPERATED DIRECTIONAL … 1000 38 69 7/8-14 DE-S2F SD18 2 WAY 2 POSITION NORMALLY CLOSED POPPET VALVES SLID PRATD DIRTIAL TRLS Page SD3 Via Malavolti, 36 • 41122 Modena •

SOLENOID OPERATED DIRECTIONAL CONTROLS

Page SD133

Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512 mail: [email protected] • www.tecnord.com

4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 mail: [email protected] • www.delta-power.com

WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken without independent study, evaluation, and testing for suitability.

W 2

0 /

2018

DIMENSIONS

ORDERING INFORMATIONApproximate Coil Weight: .89 lbs (.41 kg)

OPTIONS BODIESBuna Standard 00 Blank Without BodyViton Standard V0 S #10 SAE Ports

VOLTAGE06 6 VDC

“T” COIL TERMINATION 12 12 VDC(All DC Except as Noted) 24 24 VDC

Double Lead DL 36 36 VDCDeutsch on Leads DT 48 48 VDC

Metri-Pack on Leads ML 25 24 VACPackard on Leads PL 11 120 VAC

Weatherpack on Leads WL 22 220 VACDouble Spade DS

DIN 43650 (Hirschmann) - (AC&DC) HC

HV-S4A – – – –

DELTA POWER

2.09 [53.2]

1.00 [25.4]

HEX NUT1.80

[45.7]

3.90 [99.0]

1.23 [31.3]

3.80 [96.4]

1 1/16-12 UN2A THREAD

1.25 [31.7] HEX

SEE COIL DATAFOR TERMINATIONS

DELTA POWER

3.82 [97.0]

1.80 [45.7]

.88 [22.4]

1.76 [44.7]

1.15 [29.2]

2.12 [53.9]

4.75 [120.7]

1.15 [29.2]

3.09 [78.5]

4.15 [105.4]

3.00 [76.2]

2.30 [58.4]

1.50 [38.1]

.35 [8.9]

.41 [10.3] DIA.MTG. HOLES2X

#10 SAE PORTS4X

BODY WEIGHT: 5.08 lbs (2.3 kg)

Page 126: SOLENOID OPERATED DIRECTIONAL … 1000 38 69 7/8-14 DE-S2F SD18 2 WAY 2 POSITION NORMALLY CLOSED POPPET VALVES SLID PRATD DIRTIAL TRLS Page SD3 Via Malavolti, 36 • 41122 Modena •

SOLENOID OPERATED DIRECTIONAL CONTROLS

Page SD136

Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512 mail: [email protected] • www.tecnord.com

4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 mail: [email protected] • www.delta-power.com

WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken without independent study, evaluation, and testing for suitability.

W 20 / 2018

PQ-S4B DIRECT ACTING SPOOL, 4 WAY 2 POSITION, CLOSED CENTER

DESCRIPTION8 size, 3/4 -16 thread, “Power” series, solenoid operated, 4 way 2 position, closed center spool valve.

OPERATIONWhen de-energized the PQ-S4B blocks flow at all ports. When energized the valve allows flow from (2) to (1) and from (3) to (4).OPERATION OF MANUAL OVERRIDE OPTION: to override, pull knob out. On the detented version, after pulling knob out twist 180 degrees and release. The valve will remain in that position.

FEATURES • Hardened parts for long life.• Efficient wet-armature construction.• Cartridges are voltage interchangeable.• Manual override option.• Industry common cavity.• Unitized, molded coil design.• Continuous duty rated solenoid.• Optional coil voltages and terminations.• Optional “I” Coil: Weatherproof, Thermal Shock, Immersion Safe.

Nominal Flow 4 GPM (15 LPM)Rated Operating Pressure 3000 PSI (207 bar)Typical Internal Leakage (150 SSU) 5 cu in/min (82 ml/min)Viscosity Range 36 to 3000 SSU (3 to 647 cSt)Filtration ISO 18/16/13Media Operating Temp. Range -40° to 250°F (-40° to 120°C)Weight .24 lbs (.11 kg)Operating Fluid Media General Purpose Hydraulic FluidCartridge Torque Requirements 25 ft-lbs (34 Nm)Coil Nut Torque Requirements 4-6 ft-lbs (5.4-8.1 Nm)Cavity POWER 4WCavity Tools Kit (form tool, reamer, tap) 40500029Seal Kit 21191108

0

25

50

75

100

0 2 4

125

6Flow (GPM)

0

5

0 5 10 2015

Pres

sure

Dro

p (P

SI)

Flow (LPM)

Pres

sure

Dro

p (b

ar)

Port 2 to 1 (eng) Port 3 to 4 (eng)

Actual Test Data (Cartridge Only)

VALVE SPECIFICATIONSPERFORMANCE

HYDRAULIC SYMBOL Modes of shift operation to 6 GPM, Consult Factory.

4

1

2

3

Page 127: SOLENOID OPERATED DIRECTIONAL … 1000 38 69 7/8-14 DE-S2F SD18 2 WAY 2 POSITION NORMALLY CLOSED POPPET VALVES SLID PRATD DIRTIAL TRLS Page SD3 Via Malavolti, 36 • 41122 Modena •

SOLENOID OPERATED DIRECTIONAL CONTROLS

Page SD137

Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512 mail: [email protected] • www.tecnord.com

4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 mail: [email protected] • www.delta-power.com

WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken without independent study, evaluation, and testing for suitability.

W 2

0 /

2018

DIMENSIONS

ORDERING INFORMATIONApproximate Coil Weight: .42 lbs (.19 kg)

OPTIONS BODIESBuna Standard 00 Blank Without BodyViton Standard V0 N 1/4 NPTF Ports

Buna, Override, Detent 0M S #6 SAE PortsViton, Override, Detent VM

Buna, Override, Nondetent B1Buna, Override, Nondetent V1

VOLTAGE06 6 VDC12 12 VDC24 24 VDC36 36 VDC48 48 VDC25 24 VAC11 120 VAC22 220 VAC

“P” COIL TERMINATION 44 440 VAC(All DC Except as Noted)

IMMERSION PROOF “P” TYPEDL Double Lead SS Single Spade IA “I” Coil AMP Superseal - IntegralDT Deutsch on Leads DT04-2P DS Double Spade ID “I” Coil Deutsch - Integral DT04-2PML Metri-Pack on Leads HC DIN 43650 (Hirschmann) - (AC&DC) IJ “I” Coil AMP Jr. Timer - IntegralPL Packard on Leads CL Conduit Lead - (AC Only) IM “I” Coil Metri-Pack - IntegralWL Weatherpack on Leads DI Deutsch - Integral DT04-2P

PQ-S4B – – – –D

ELTA

PO

WE

R

2.89 [73.5] 2.13

[54.2]

2.11 [53.6]

.25 [6.3]

3/4-16 UNF2A THREAD

1.25 [31.7]

1.54 [39.1]

.86 [22.2] HEX

MANUAL OVERRIDE

STANDARD

.75 [19.1]

HEX NUT

SEE COILDATA FOR TERMINATIONS

DE

LTA P

OW

ER

1.25 [31.8]

.63 [15.9]

2.10 [53.4]

.59 [15.1]

1.72 [43.7]

2.75 [69.9]

.25 [6.4]

1.16 [29.4]

3.00 [76.2]

2.25 [57.2]

1.75 [44.5]

1.13 [28.6]

.25 [6.4]

.28 [7.13] DIA.MTG. HOLES2X

#6 SAE PORTS4X

BODY WEIGHT: .67 lbs (.30 kg)

Page 128: SOLENOID OPERATED DIRECTIONAL … 1000 38 69 7/8-14 DE-S2F SD18 2 WAY 2 POSITION NORMALLY CLOSED POPPET VALVES SLID PRATD DIRTIAL TRLS Page SD3 Via Malavolti, 36 • 41122 Modena •

SOLENOID OPERATED DIRECTIONAL CONTROLS

Page SD138

Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512 mail: [email protected] • www.tecnord.com

4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 mail: [email protected] • www.delta-power.com

WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken without independent study, evaluation, and testing for suitability.

W 20 / 2018

DG-S4B DIRECT ACTING SPOOL, 4 WAY 2 POSITION, CLOSED CENTER

DESCRIPTION10 size, 7/8-14 thread, “Delta” series, solenoid operated, 4 way 2 position, closed center spool valve.

OPERATIONWhen de-energized the DG-S4B blocks flow at all ports. When energized the valve allows flow from (2) to (1) and (3) to (4).OPERATION OF MANUAL OVERRIDE OPTION: to override, turn the manual override screw counterclockwise. To release turn the manual override screw clockwise.

FEATURES • Hardened parts for long life.• Efficient wet-armature construction.• Cartridges are voltage interchangeable.• Manual override option.• Industry common cavity.• Unitized, molded coil design.• Continuous duty rated solenoid.• Optional coil voltages and terminations.• Optional “I” Coil: Weatherproof, Thermal Shock, Immersion Safe.

Nominal Flow 10 GPM (38 LPM)Rated Operating Pressure 3000 PSI (207 bar)Typical Internal Leakage (150 SSU) 5 cu in/min (82 ml/min) per pathViscosity Range 36 to 3000 SSU (3 to 647 cSt)Filtration ISO 18/16/13Media Operating Temp. Range -40° to 250°F (-40° to 120°C)Weight .32 lbs (.15 kg)Operating Fluid Media General Purpose Hydraulic FluidCartridge Torque Requirements 30 ft-lbs (40.6 Nm)Coil Nut Torque Requirements 4-6 ft-lbs (5.4-8.1 Nm)Cavity DELTA 4WCavity Tools Kit (form tool, reamer, tap) 40500002Seal Kit 21191214

0

50

100

150

200

0 2 64 8 10 12

Flow (GPM)

0

5

10

0 10 20

Pres

sure

Dro

p (P

SI)

30 40Flow (LPM)

Pres

sure

Dro

p (b

ar)

Port 2 to 1 (eng) Port 3 to 4 (eng)

Actual Test Data (Cartridge Only)

VALVE SPECIFICATIONS

For higher pressures see HG-S4B. Operational shift limit, 10 GPM (38 LPM). For shift performance consult chart.

PERFORMANCE

HYDRAULIC SYMBOL

4

1

2

3

Page 129: SOLENOID OPERATED DIRECTIONAL … 1000 38 69 7/8-14 DE-S2F SD18 2 WAY 2 POSITION NORMALLY CLOSED POPPET VALVES SLID PRATD DIRTIAL TRLS Page SD3 Via Malavolti, 36 • 41122 Modena •

SOLENOID OPERATED DIRECTIONAL CONTROLS

Page SD139

Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512 mail: [email protected] • www.tecnord.com

4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 mail: [email protected] • www.delta-power.com

WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken without independent study, evaluation, and testing for suitability.

W 2

0 /

2018

DIMENSIONS

ORDERING INFORMATIONApproximate Coil Weight: .74 lbs (.33 kg)

OPTIONS BODIESBuna Standard 00 Blank Without BodyViton Standard V0 N 1/4 NPTF Ports

Buna, Override, Detent 0M S #6 SAE PortsViton, Override, Detent VM

Buna, Override, Non-detent B1Viton, Override, Non-detent V1 VOLTAGE

06 6 VDC12 12 VDC24 24 VDC36 36 VDC48 48 VDC25 24 VAC11 120 VAC22 220 VAC44 440 VAC

“D” COIL TERMINATION(All DC Except as Noted)

IMMERSION PROOF “D” TYPEDL Double Lead SS Single Spade IA “I” Coil AMP Superseal - IntegralDT Deutsch on Leads DT04-2P DS Double Spade ID “I” Coil - Deutsch - Integral DT04-2PML Metri-Pack on Leads HC DIN 43650 (Hirschmann) - (AC&DC) IJ “I” Coil AMP Jr. Timer - IntegralPL Packard on Leads CL Conduit Lead - (AC Only) IM “I” Coil - Metri-Pack - IntegralWL Weatherpack on Leads DI Deutsch - Integral DT04-2P

DG-S4B – – – –

DE

LTA PO

WE

R

1.56 [39.6]

1.83 [46.6]

.75 [19.1]

HEX NUT

3.35 [85.1] 2.31

[58.8]

2.44 [61.9]

.22 [5.6]

1.00 [25.4] HEX

7/8-14 UNF-2A

7/16-20 UNF-2ATHREAD

MANUAL OVERRIDE

STANDARD

SEE COILDATA FORTERMINATIONS

DE

LTA P

OW

ER

1.56 [39.6]

1.50 [38.1]

.81 [20.6]

2.27 [57.8]

.63 [15.9]

2.00 [50.8]

3.25 [82.6]

1.38 [34.9]

2.88 [73.0]

2.50 [63.5]

2.25 [57.2]

1.25 [31.8]

.13 [3.2]

.28 [7.1] DIA.MTG. SLOTS2X

#6 SAE PORTS4X

BODY WEIGHT: .99 lbs (.45 kg)

Page 130: SOLENOID OPERATED DIRECTIONAL … 1000 38 69 7/8-14 DE-S2F SD18 2 WAY 2 POSITION NORMALLY CLOSED POPPET VALVES SLID PRATD DIRTIAL TRLS Page SD3 Via Malavolti, 36 • 41122 Modena •

SOLENOID OPERATED DIRECTIONAL CONTROLS

Page SD140

Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512 mail: [email protected] • www.tecnord.com

4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 mail: [email protected] • www.delta-power.com

WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken without independent study, evaluation, and testing for suitability.

W 20 / 2018

HG-S4B DIRECT ACTING SPOOL, 4 WAY 2 POSITION, CLOSED CENTER

DESCRIPTION“High Pressure” 10 size, 7/8-14 thread, “Delta” series, solenoid operated, 4 way 2 position closed center spool valve.

OPERATIONWhen de-energized the HG-S4B blocks flow at all ports. When energized the valve allows flow from (2) to (1) and from (3) to (4).

FEATURES • Hardened parts for long life.• Efficient wet-armature construction.• Cartridges are voltage interchangeable.• Industry common cavity.• Unitized, molded coil design.• Continuous duty rated solenoid.• Optional coil voltages and terminations.• Optional “I” Coil: Weatherproof, Thermal Shock, Immersion Safe.

Nominal Flow 10 GPM (38 LPM) Rated Operating Pressure 4000 PSI (276 bar)Typical Internal Leakage (150 SSU) 10 cu in/min (164 ml/min) per pathViscosity Range 36 to 3000 SSU (3 to 647 cSt)Filtration ISO 18/16/13Media Operating Temp. Range -40° to 250°F (-40° to 120°C)Weight .44 lbs (.20 kg)Operating Fluid Media General Purpose Hydraulic FluidCartridge Torque Requirements 30 ft-lbs (40.6 Nm)Coil Nut Torque Requirements 4-6 ft-lbs (5.4-8.1 Nm)Cavity DELTA 4WCavity Tools Kit (form tool, reamer, tap) 40500002Seal Kit 21191214

0

50

100

150

2

200

0 4 86 10 12Flow (GPM)

0

5

10

0 10 20 30 40

Pres

sure

Dro

p (P

SI)

Flow (LPM)

Pres

sure

Dro

p (b

ar)

Port 2 to 1 (eng) Port 3 to 4 (eng)

Actual Test Data (Cartridge Only)

VALVE SPECIFICATIONSPERFORMANCE

HYDRAULIC SYMBOL Uses “L” Coils.Pressure differential between ports should not exceed 3000 PSI.

4

1

2

3

Page 131: SOLENOID OPERATED DIRECTIONAL … 1000 38 69 7/8-14 DE-S2F SD18 2 WAY 2 POSITION NORMALLY CLOSED POPPET VALVES SLID PRATD DIRTIAL TRLS Page SD3 Via Malavolti, 36 • 41122 Modena •

SOLENOID OPERATED DIRECTIONAL CONTROLS

Page SD141

Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512 mail: [email protected] • www.tecnord.com

4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 mail: [email protected] • www.delta-power.com

WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken without independent study, evaluation, and testing for suitability.

W 2

0 /

2018

Note: Aluminum, NOT durability rated for 4000 PSI. Consult factory for body options.

DIMENSIONS

ORDERING INFORMATIONApproximate Coil Weight: .68 lbs (.31 kg)

OPTIONS BODIESBuna Standard 00 Blank Without BodyViton Standard V0 N 1/4 NPTF Ports

S #6 SAE Ports

VOLTAGE06 6 VDC12 12 VDC24 24 VDC36 36 VDC48 48 VDC25 24 VAC11 120 VAC22 220 VAC

“L” COIL TERMINATION 44 440 VAC(All DC Except as Noted)

IMMERSION PROOF “L” TYPEDL Double Lead SS Single Spade IA “I” Coil AMP Superseal - IntegralDT Deutsch on Leads DT04-2P DS Double Spade ID “I” Coil Deutsch - Integral DT04-2PML Metri-Pack on Leads HC DIN 43650 (Hirschmann) - (AC&DC) IJ “I” Coil AMP Jr. Timer - IntegralPL Packard on Leads CL Conduit Lead - (AC Only) IM “I” Coil Metri-Pack - IntegralWL Weatherpack on Leads DI Deutsch - Integral DT04-2P

HG-S4B – – – –

DE

LTA P

OW

ER

1.56 [39.6]

1.83 [46.6]

.75 [19.1]

HEX NUT

2.63 [66.8]

.50 [12.7]

2.44 [61.9]

7/8-14 UNF-2A THREAD

1.00 [25.4] HEX

SEE COILDATA FORTERMINATIONS

DE

LTA P

OW

ER

1.56 [39.6]

1.50 [38.1]

.81 [20.6]

2.59 [65.7]

.63 [15.9]

2.00 [50.8]

1.38 [34.9]

2.88 [73.0]

3.25 [82.6]

2.50 [63.5]

2.25 [57.2]

1.25 [31.8]

.13 [3.2]

.281 [7.14] DIA2X

#6 SAE PORTS4X

BODY WEIGHT: .99 lbs (.45 kg)

Page 132: SOLENOID OPERATED DIRECTIONAL … 1000 38 69 7/8-14 DE-S2F SD18 2 WAY 2 POSITION NORMALLY CLOSED POPPET VALVES SLID PRATD DIRTIAL TRLS Page SD3 Via Malavolti, 36 • 41122 Modena •

SOLENOID OPERATED DIRECTIONAL CONTROLS

Page SD142

Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512 mail: [email protected] • www.tecnord.com

4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 mail: [email protected] • www.delta-power.com

WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken without independent study, evaluation, and testing for suitability.

W 20 / 2018

PQ-S4C DIRECT ACTING SPOOL, 4 WAY 2 POSITION, TANDEM CENTER

DESCRIPTION8 size, 3/4-16 thread, “Power” series, solenoid operated, 4 way 2 position, tandem center spool valve.

OPERATIONWhen de-energized the PQ-S4C allows flow between (2) and (4), blocks flow at (1) and (3). When energized the valve allows flow from (2) to (3) and from (1) to (4).OPERATION OF MANUAL OVERRIDE OPTION: to override, pull knob out. On the detented version, after pulling knob out twist 180 degrees and release. The valve will remain in that position.

FEATURES • Hardened parts for long life.• Efficient wet-armature construction.• Cartridges are voltage interchangeable.• Manual override option.• Industry common cavity.• Unitized, molded coil design.• Continuous duty rated solenoid.• Optional coil voltages and terminations.• Optional “I” Coil: Weatherproof, Thermal Shock, Immersion Safe.

Nominal Flow 4 GPM (15 LPM)Rated Operating Pressure 3000 PSI (207 bar)Typical Internal Leakage (150 SSU) 5 cu in/min (82 ml/min) per pathViscosity Range 36 to 3000 SSU (3 to 647 cSt)Filtration ISO 18/16/13Media Operating Temp. Range -40° to 250°F (-40° to 120°C)Weight .24 lbs (.11 kg)Operating Fluid Media General Purpose Hydraulic FluidCartridge Torque Requirements 25 ft-lbs (34 Nm)Coil Nut Torque Requirements 4-6 ft-lbs (5.4-8.1 Nm)Cavity POWER 4WCavity Tools Kit (form tool, reamer, tap) 40500029Seal Kit 21191108

0

50

100

150

200

0

250

1 53 42Flow (GPM)

0

5

10

15

0 5 10

Pre

ssur

e D

rop

(PS

I)

15Flow (LPM)

Pre

ssur

e D

rop

(bar

)

Port 1 to 4 (eng) Port 2 to 3 (eng) Port 2 to 4 (de-eng)

Actual Test Data (Cartridge Only)

HYDRAULIC SYMBOL

PERFORMANCE VALVE SPECIFICATIONS

4

1

2

3

Page 133: SOLENOID OPERATED DIRECTIONAL … 1000 38 69 7/8-14 DE-S2F SD18 2 WAY 2 POSITION NORMALLY CLOSED POPPET VALVES SLID PRATD DIRTIAL TRLS Page SD3 Via Malavolti, 36 • 41122 Modena •

SOLENOID OPERATED DIRECTIONAL CONTROLS

Page SD143

Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512 mail: [email protected] • www.tecnord.com

4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 mail: [email protected] • www.delta-power.com

WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken without independent study, evaluation, and testing for suitability.

W 2

0 /

2018

DIMENSIONS

ORDERING INFORMATIONApproximate Coil Weight: .42 lbs (.19 kg)

OPTIONS BODIESBuna Standard 00 Blank Without BodyViton Standard V0 N 1/4 NPTF Ports

Buna, Override, Detent 0M S #6 SAE PortsViton, Override, Detent VM

Buna, Override, Nondetent B1Buna, Override, Nondetent V1

VOLTAGE06 6 VDC12 12 VDC24 24 VDC36 36 VDC48 48 VDC25 24 VAC11 120 VAC22 220 VAC

“P” COIL TERMINATION 44 440 VAC(All DC Except as Noted)

IMMERSION PROOF “P” TYPEDL Double Lead SS Single Spade IA “I” Coil AMP Superseal - IntegralDT Deutsch on Leads DT04-2P DS Double Spade ID “I” Coil Deutsch - Integral DT04-2PML Metri-Pack on Leads HC DIN 43650 (Hirschmann) - (AC&DC) IJ “I” Coil AMP Jr. Timer - IntegralPL Packard on Leads CL Conduit Lead - (AC Only) IM “I” Coil Metri-Pack - IntegralWL Weatherpack on Leads DI Deutsch - Integral DT04-2P

PQ-S4C – – – –D

ELTA

PO

WE

R

2.89 [73.5] 2.13

[54.2]

2.11 [53.6]

.25 [6.3]

3/4-16 UNF2A THREAD

1.25 [31.7]

1.54 [39.1]

.86 [22.2] HEX

MANUAL OVERRIDE

STANDARD

.75 [19.1]

HEX NUT

SEE COILDATA FOR TERMINATIONS

DE

LTA P

OW

ER

1.25 [31.8]

.63 [15.9]

2.10 [53.4]

.59 [15.1]

1.72 [43.7]

2.75 [69.9]

.25 [6.4]

1.16 [29.4]

3.00 [76.2]

2.25 [57.2]

1.75 [44.5]

1.13 [28.6]

.25 [6.4]

.28 [7.13] DIA.MTG. HOLES2X

#6 SAE PORTS4X

BODY WEIGHT: .67 lbs (.30 kg)

Page 134: SOLENOID OPERATED DIRECTIONAL … 1000 38 69 7/8-14 DE-S2F SD18 2 WAY 2 POSITION NORMALLY CLOSED POPPET VALVES SLID PRATD DIRTIAL TRLS Page SD3 Via Malavolti, 36 • 41122 Modena •

SOLENOID OPERATED DIRECTIONAL CONTROLS

Page SD144

Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512 mail: [email protected] • www.tecnord.com

4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 mail: [email protected] • www.delta-power.com

WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken without independent study, evaluation, and testing for suitability.

W 20 / 2018

DG-S4C DIRECT ACTING SPOOL, 4 WAY 2 POSITION, TANDEM CENTER

DESCRIPTION10 size, 7/8 -14 thread, “Delta” series, solenoid operated, 4 way 2 position, tandem center spool valve.

OPERATIONWhen de-energized the DG-S4C allows flow between (2) and (4), and blocks flow at ports (1) and (3). When energized the valve allows flow from (2) to (3) and (1) to (4).OPERATION OF MANUAL OVERRIDE OPTION: to override, pull knob out. On the detented version, after pulling knob out twist 180 degrees and release. The valve will remain in that position.

FEATURES • Hardened parts for long life.• Efficient wet-armature construction.• Cartridges are voltage interchangeable.• Manual override option.• Industry common cavity.• Unitized, molded coil design.• Continuous duty rated solenoid.• Optional coil voltages and terminations.• Optional “I” Coil: Weatherproof, Thermal Shock, Immersion Safe.

Nominal Flow 8 GPM (30 LPM)Rated Operating Pressure 3000 PSI (207 bar)Typical Internal Leakage (150 SSU) 5 cu in/min (82 ml/min) per pathViscosity Range 36 to 3000 SSU (3 to 647 cSt)Filtration ISO 18/16/13Media Operating Temp. Range -40° to 250°F (-40° to 120°C)Weight .31 lbs (.14 kg)Operating Fluid Media General Purpose Hydraulic FluidCartridge Torque Requirements 30 ft-lbs (40.6 Nm)Coil Nut Torque Requirements 4-6 ft-lbs (5.4-8.1 Nm)Cavity DELTA 4WCavity Tools Kit (form tool, reamer, tap) 40500002Seal Kit 21191214

0

50

100

150

200

0 2 4 86 10 12

Flow (GPM)

0

5

10

0 5

Pres

sure

Dro

p (P

SI)

10 15 2520 30 4035 45

Flow (LPM)

Pres

sure

Dro

p (b

ar)

Port 1 to 4 (eng) Port 2 to 3 (eng) Port 2 to 4 (de-eng)

Actual Test Data (Cartridge Only)

VALVE SPECIFICATIONS

For higher pressures see HG-S4C. Operational shift limit, 8 GPM (30 LPM). For shift performance consult chart.

PERFORMANCE

HYDRAULIC SYMBOL

4

1

2

3

Page 135: SOLENOID OPERATED DIRECTIONAL … 1000 38 69 7/8-14 DE-S2F SD18 2 WAY 2 POSITION NORMALLY CLOSED POPPET VALVES SLID PRATD DIRTIAL TRLS Page SD3 Via Malavolti, 36 • 41122 Modena •

SOLENOID OPERATED DIRECTIONAL CONTROLS

Page SD145

Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512 mail: [email protected] • www.tecnord.com

4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 mail: [email protected] • www.delta-power.com

WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken without independent study, evaluation, and testing for suitability.

W 2

0 /

2018

DIMENSIONS

ORDERING INFORMATIONApproximate Coil Weight: .74 lbs (.33 kg)

OPTIONS BODIESBuna Standard 00 Blank Without BodyViton Standard V0 N 1/4 NPTF Ports

Buna, Override, Detent 0M S #6 SAE PortsViton, Override, Detent VM

Buna, Override, Non-detent B1Viton, Override, Non-detent V1 VOLTAGE

06 6 VDC12 12 VDC24 24 VDC36 36 VDC48 48 VDC25 24 VAC11 120 VAC22 220 VAC44 440 VAC

“D” COIL TERMINATION(All DC Except as Noted)

IMMERSION PROOF “D” TYPEDL Double Lead SS Single Spade IA “I” Coil AMP Superseal - IntegralDT Deutsch on Leads DT04-2P DS Double Spade ID “I” Coil - Deutsch - Integral DT04-2PML Metri-Pack on Leads HC DIN 43650 (Hirschmann) - (AC&DC) IJ “I” Coil AMP Jr. Timer - IntegralPL Packard on Leads CL Conduit Lead - (AC Only) IM “I” Coil - Metri-Pack - IntegralWL Weatherpack on Leads DI Deutsch - Integral DT04-2P

DG-S4C – – – –

DE

LTA PO

WE

R

1.56 [39.6]

1.83 [46.6]

.75 [19.1]

HEX NUT

3.35 [85.1] 2.31

[58.8]

2.44 [61.9]

.22 [5.6]

1.00 [25.4] HEX

7/8-14 UNF-2A

7/16-20 UNF-2ATHREAD

MANUAL OVERRIDE

STANDARD

SEE COILDATA FORTERMINATIONS

DE

LTA P

OW

ER

1.56 [39.6]

1.50 [38.1]

.81 [20.6]

2.27 [57.8]

.63 [15.9]

2.00 [50.8]

3.25 [82.6]

1.38 [34.9]

2.88 [73.0]

2.50 [63.5]

2.25 [57.2]

1.25 [31.8]

.13 [3.2]

.28 [7.1] DIA.MTG. SLOTS2X

#6 SAE PORTS4X

BODY WEIGHT: .99 lbs (.45 kg)

Page 136: SOLENOID OPERATED DIRECTIONAL … 1000 38 69 7/8-14 DE-S2F SD18 2 WAY 2 POSITION NORMALLY CLOSED POPPET VALVES SLID PRATD DIRTIAL TRLS Page SD3 Via Malavolti, 36 • 41122 Modena •

SOLENOID OPERATED DIRECTIONAL CONTROLS

Page SD146

Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512 mail: [email protected] • www.tecnord.com

4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 mail: [email protected] • www.delta-power.com

WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken without independent study, evaluation, and testing for suitability.

W 20 / 2018

HG-S4C DIRECT ACTING SPOOL, 4 WAY 2 POSITION, TANDEM CENTER

DESCRIPTION“High Pressure” 10 size, 7/8-14 thread, “Delta” series, solenoid operated, 4 way 2 position tandem center spool valve.

OPERATIONWhen de-energized the HG-S4C allows flow between (2) and (4) and blocks the flow at (1) and (3).When energized the valve allows flow from (2) to (3) and from (1) to (4).

FEATURES • Hardened parts for long life.• Efficient wet-armature construction.• Cartridges are voltage interchangeable.• Industry common cavity.• Unitized, molded coil design.• Continuous duty rated solenoid.• Optional coil voltages and terminations.• Optional “I” Coil: Weatherproof, Thermal Shock, Immersion Safe.

Nominal Flow 8 GPM (30 LPM) Rated Operating Pressure 4000 PSI (276 bar)Typical Internal Leakage (150 SSU) 10 cu in/min (164 ml/min) per pathViscosity Range 36 to 3000 SSU (3 to 647 cSt)Filtration ISO 18/16/13Media Operating Temp. Range -40° to 250°F (-40° to 120°C)Weight .43 lbs (.20 kg)Operating Fluid Media General Purpose Hydraulic FluidCartridge Torque Requirements 30 ft-lbs (40,6 Nm)Coil Nut Torque Requirements 4-6 ft-lbs (5.4-8.1 Nm)Cavity DELTA 4WCavity Tools Kit (form tool, reamer, tap) 40500002Seal Kit 21191214

0

50

100

150

200

0 2 4 86 10 12Flow (GPM)

0

5

10

0 10 20 30 40

Pre

ssur

e D

rop

(PS

I)

Pre

ssur

e D

rop

(bar

)

Flow (LPM)

Port 1 to 4 (eng) Port 2 to 3 (eng) Port 2 to 4 (de-eng)

Actual Test Data (Cartridge Only)

VALVE SPECIFICATIONSPERFORMANCE

HYDRAULIC SYMBOL

4

1

2

3

Uses “L” Coils.Pressure differential between ports should not exceed 3000 PSI.

Page 137: SOLENOID OPERATED DIRECTIONAL … 1000 38 69 7/8-14 DE-S2F SD18 2 WAY 2 POSITION NORMALLY CLOSED POPPET VALVES SLID PRATD DIRTIAL TRLS Page SD3 Via Malavolti, 36 • 41122 Modena •

SOLENOID OPERATED DIRECTIONAL CONTROLS

Page SD147

Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512 mail: [email protected] • www.tecnord.com

4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 mail: [email protected] • www.delta-power.com

WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken without independent study, evaluation, and testing for suitability.

W 2

0 /

2018

DIMENSIONS

ORDERING INFORMATIONApproximate Coil Weight: .68 lbs (.31 kg)

OPTIONS BODIESBuna Standard 00 Blank Without BodyViton Standard V0 N 1/4 NPTF Ports

S #6 SAE Ports

VOLTAGE06 6 VDC12 12 VDC24 24 VDC36 36 VDC48 48 VDC25 24 VAC11 120 VAC22 220 VAC

“L” COIL TERMINATION 44 440 VAC(All DC Except as Noted)

IMMERSION PROOF “L” TYPEDL Double Lead SS Single Spade IA “I” Coil AMP Superseal - IntegralDT Deutsch on Leads DT04-2P DS Double Spade ID “I” Coil Deutsch - Integral DT04-2PML Metri-Pack on Leads HC DIN 43650 (Hirschmann) - (AC&DC) IJ “I” Coil AMP Jr. Timer - IntegralPL Packard on Leads CL Conduit Lead - (AC Only) IM “I” Coil Metri-Pack - IntegralWL Weatherpack on Leads DI Deutsch - Integral DT04-2P

HG-S4C – – – –

Note: Aluminum, NOT durability rated for 4000 PSI. Consult factory for body options.

DE

LTA P

OW

ER

1.56 [39.6]

1.83 [46.6]

.75 [19.1]

HEX NUT

2.63 [66.8]

.50 [12.7]

2.44 [61.9]

7/8-14 UNF-2A THREAD

1.00 [25.4] HEX

SEE COILDATA FORTERMINATIONS

DE

LTA P

OW

ER

1.56 [39.6]

1.50 [38.1]

.81 [20.6]

2.59 [65.7]

.63 [15.9]

2.00 [50.8]

1.38 [34.9]

2.88 [73.0]

3.25 [82.6]

2.50 [63.5]

2.25 [57.2]

1.25 [31.8]

.13 [3.2]

.281 [7.14] DIA2X

#6 SAE PORTS4X

BODY WEIGHT: .99 lbs (.45 kg)

Page 138: SOLENOID OPERATED DIRECTIONAL … 1000 38 69 7/8-14 DE-S2F SD18 2 WAY 2 POSITION NORMALLY CLOSED POPPET VALVES SLID PRATD DIRTIAL TRLS Page SD3 Via Malavolti, 36 • 41122 Modena •

SOLENOID OPERATED DIRECTIONAL CONTROLS

Page SD148

Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512 mail: [email protected] • www.tecnord.com

4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 mail: [email protected] • www.delta-power.com

WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken without independent study, evaluation, and testing for suitability.

W 20 / 2018

PQ-S4D DIRECT ACTING SPOOL, 4 WAY 2 POSITION, CRISS CROSS

DESCRIPTION8 size, 3/4-16 thread, “Power” series, solenoid operated, 4 way 2 position, criss cross, bottom flow spool valve.

OPERATIONWhen de-energized the PQ-S4D allows flow from (3) to (2), and from (4) to (1). When energized the valve allows flow from (1) to (2) and from (4) to (3).OPERATION OF MANUAL OVERRIDE OPTION: to override, pull knob out. On the detented version, after pulling knob out twist 180 degrees and release. The valve will remain in that position.

FEATURES • Hardened parts for long life.• Efficient wet-armature construction.• Cartridges are voltage interchangeable.• Manual override option.• Industry common cavity.• Unitized, molded coil design.• Continuous duty rated solenoid.• Optional coil voltages and terminations.• Optional “I” Coil: Weatherproof, Thermal Shock, Immersion Safe.

Nominal Flow 2.5 GPM (9.5 LPM)Rated Operating Pressure 3000 PSI (207 bar)Typical Internal Leakage (150 SSU) 5 cu in/min (82 ml/min) per pathViscosity Range 36 to 3000 SSU (3 to 647 cSt)Filtration ISO 18/16/13Media Operating Temp. Range -40° to 250°F (-40° to 120°C)Weight .24 lbs (.11 kg)Operating Fluid Media General Purpose Hydraulic FluidCartridge Torque Requirements 25 ft-lbs (34 Nm)Coil Nut Torque Requirements 4-6 ft-lbs (5.4-8.1 Nm)Cavity POWER 4WCavity Tools Kit (form tool, reamer, tap) 40500029Seal Kit 21191108

0

50

100

150

200

0 3 4 521Flow (GPM)

0

5

10

0 5 10 15

Pre

ssur

e D

rop

(PS

I)

Flow (LPM)

Pre

ssur

e D

rop

(bar

)

Port 1 to 2 (eng) Port 4 to 3 (eng)

0

50

100

150

10 2

200

3 54Flow (GPM)

0

5

10

Pre

ssur

e D

rop

(PS

I)

0 5 10 15Flow (LPM)

Pre

ssur

e D

rop

(bar

)

Port 3 to 2 (de-eng) Port 4 to 1 (de-eng)

Actual Test Data (Cartridge Only)

PERFORMANCE HYDRAULIC SYMBOL

VALVE SPECIFICATIONS

Modes of shift operation to 3 GPM, Consult Factory.

4

1

2

3

Page 139: SOLENOID OPERATED DIRECTIONAL … 1000 38 69 7/8-14 DE-S2F SD18 2 WAY 2 POSITION NORMALLY CLOSED POPPET VALVES SLID PRATD DIRTIAL TRLS Page SD3 Via Malavolti, 36 • 41122 Modena •

SOLENOID OPERATED DIRECTIONAL CONTROLS

Page SD149

Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512 mail: [email protected] • www.tecnord.com

4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 mail: [email protected] • www.delta-power.com

WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken without independent study, evaluation, and testing for suitability.

W 2

0 /

2018

DIMENSIONS

ORDERING INFORMATIONApproximate Coil Weight: .42 lbs (.19 kg)

OPTIONS BODIESBuna Standard 00 Blank Without BodyViton Standard V0 N 1/4 NPTF Ports

Buna, Override, Detent 0M S #6 SAE PortsViton, Override, Detent VM

Buna, Override, Nondetent B1Buna, Override, Nondetent V1

VOLTAGE06 6 VDC

12 12 VDC24 24 VDC36 36 VDC48 48 VDC25 24 VAC11 120 VAC22 220 VAC

“P” COIL TERMINATION 44 440 VAC(All DC Except as Noted)

IMMERSION PROOF “D” TYPEDL Double Lead SS Single Spade IA “I” Coil AMP Superseal - IntegralDT Deutsch on Leads DT04-2P DS Double Spade ID “I” Coil Deutsch - Integral DT04-2PML Metri-Pack on Leads HC DIN 43650 (Hirschmann) - (AC&DC) IJ “I” Coil AMP Jr. Timer - IntegralPL Packard on Leads CL Conduit Lead - (AC Only) IM “I” Coil Metri-Pack - IntegralWL Weatherpack on Leads DI Deutsch - Integral DT04-2P

PQ-S4D – – – –

Page 140: SOLENOID OPERATED DIRECTIONAL … 1000 38 69 7/8-14 DE-S2F SD18 2 WAY 2 POSITION NORMALLY CLOSED POPPET VALVES SLID PRATD DIRTIAL TRLS Page SD3 Via Malavolti, 36 • 41122 Modena •

SOLENOID OPERATED DIRECTIONAL CONTROLS

Page SD150

Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512 mail: [email protected] • www.tecnord.com

4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 mail: [email protected] • www.delta-power.com

WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken without independent study, evaluation, and testing for suitability.

W 20 / 2018

DG-S4D DIRECT ACTING SPOOL, 4 WAY 2 POSITION, CRISS CROSS

DESCRIPTION10 size, 7/8-14 thread, “Delta” series, solenoid operated, 4 way 2 position, criss cross, bottom flow spool valve.

OPERATIONWhen de-energized the DG-S4D allows flow from (4) to (1), and (3) to (2). When energized the valve allows flow from (4) to (3) and (1) to (2).OPERATION OF MANUAL OVERRIDE OPTION: to override, pull knob out. On the detented version, after pulling knob out twist 180 degrees and release. The valve will remain in that position.

FEATURES • Hardened parts for long life.• Efficient wet-armature construction.• Cartridges are voltage interchangeable.• Manual override option.• Industry common cavity.• Unitized, molded coil design.• Continuous duty rated solenoid.• Optional coil voltages and terminations.• Optional “I” Coil: Weatherproof, Thermal Shock, Immersion Safe.

Nominal Flow 6 GPM (23 LPM)Rated Operating Pressure 3000 PSI (207 bar)Typical Internal Leakage (150 SSU) 5 cu in/min (82 ml/min) per pathViscosity Range 36 to 3000 SSU (3 to 647 cSt)Filtration ISO 18/16/13Media Operating Temp. Range -40° to 250°F (-40° to 120°C)Weight .31 lbs (.14 kg)Operating Fluid Media General Purpose Hydraulic FluidCartridge Torque Requirements 30 ft-lbs (40.6 Nm)Coil Nut Torque Requirements 4-6 ft-lbs (5.4-8.1 Nm)Cavity DELTA 4WCavity Tools Kit (form tool, reamer, tap) 40500002Seal Kit 21191214

0

50

100

150

0

200

2 4 6 8 10 12

Flow (GPM)

0

5

10

0 5 10 15 20 25 30 35 40 45

Pre

ssur

e D

rop

(PS

I)

Pre

ssur

e D

rop

(bar

)

Flow (LPM)

Port 1 to 2 (eng) Port 4 to 3 (eng)

0

50

100

150

420 6 8 10

Pre

ssur

e D

rop

(PS

I)

0

5

10

0 5 10

Flow (GPM)

2015 25 30 35Flow (LPM)

Pre

ssur

e D

rop

(bar

)

Port 3 to 2 (de-eng) Port 4 to 1 (de-eng)

Actual Test Data (Cartridge Only)

PERFORMANCE

For higher pressures see HG-S4D. Operational shift limit, 6 GPM (23 LPM). For shift performance consult chart.

HYDRAULIC SYMBOL

VALVE SPECIFICATIONS

4

1

2

3

Page 141: SOLENOID OPERATED DIRECTIONAL … 1000 38 69 7/8-14 DE-S2F SD18 2 WAY 2 POSITION NORMALLY CLOSED POPPET VALVES SLID PRATD DIRTIAL TRLS Page SD3 Via Malavolti, 36 • 41122 Modena •

SOLENOID OPERATED DIRECTIONAL CONTROLS

Page SD151

Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512 mail: [email protected] • www.tecnord.com

4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 mail: [email protected] • www.delta-power.com

WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken without independent study, evaluation, and testing for suitability.

W 2

0 /

2018

DIMENSIONS

ORDERING INFORMATIONApproximate Coil Weight: .74 lbs (.33 kg)

OPTIONS BODIESBuna Standard 00 Blank Without BodyViton Standard V0 N 1/4 NPTF PortsBuna, Override 0M S #6 SAE PortsViton, Override VM

Buna, Override, Non-detent B1Viton, Override, Non-detent V1 VOLTAGE

06 6 VDC12 12 VDC24 24 VDC36 36 VDC48 48 VDC25 24 VAC11 120 VAC22 220 VAC44 440 VAC

“D” COIL TERMINATION(All DC Except as Noted)

IMMERSION PROOF “D” TYPEDL Double Lead SS Single Spade IA “I” Coil AMP Superseal - IntegralDT Deutsch on Leads DT04-2P DS Double Spade ID “I” Coil - Deutsch - Integral DT04-2PML Metri-Pack on Leads HC DIN 43650 (Hirschmann) - (AC&DC) IJ “I” Coil AMP Jr. Timer - IntegralPL Packard on Leads CL Conduit Lead - (AC Only) IM “I” Coil - Metri-Pack - IntegralWL Weatherpack on Leads DI Deutsch - Integral DT04-2P

DG-S4D – – – –

DE

LTA PO

WE

R

1.56 [39.6]

1.83 [46.6]

.75 [19.1]

HEX NUT

3.35 [85.1] 2.31

[58.8]

2.44 [61.9]

.22 [5.6]

1.00 [25.4] HEX

7/8-14 UNF-2A

7/16-20 UNF-2ATHREAD

MANUAL OVERRIDE

STANDARD

SEE COILDATA FORTERMINATIONS

DE

LTA P

OW

ER

1.56 [39.6]

1.50 [38.1]

.81 [20.6]

2.27 [57.8]

.63 [15.9]

2.00 [50.8]

3.25 [82.6]

1.38 [34.9]

2.88 [73.0]

2.50 [63.5]

2.25 [57.2]

1.25 [31.8]

.13 [3.2]

.28 [7.1] DIA.MTG. SLOTS2X

#6 SAE PORTS4X

BODY WEIGHT: .99 lbs (.45 kg)

Page 142: SOLENOID OPERATED DIRECTIONAL … 1000 38 69 7/8-14 DE-S2F SD18 2 WAY 2 POSITION NORMALLY CLOSED POPPET VALVES SLID PRATD DIRTIAL TRLS Page SD3 Via Malavolti, 36 • 41122 Modena •

SOLENOID OPERATED DIRECTIONAL CONTROLS

Page SD152

Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512 mail: [email protected] • www.tecnord.com

4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 mail: [email protected] • www.delta-power.com

WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken without independent study, evaluation, and testing for suitability.

W 20 / 2018

HG-S4D DIRECT ACTING SPOOL, 4 WAY 2 POSITION, BOTTOM FLOW

DESCRIPTION“High Pressure” 10 size, 7/8-14 thread, “Delta” series, solenoid operated, 4 way 2 position bottom flow spool valve.

OPERATIONWhen de-energized the HG-S4D allows flow from (4) to (1) and from (3) to (2). When energized the valve allows flow from (4) to (3) and from (1) to (2).

FEATURES • Hardened parts for long life.• Efficient wet-armature construction.• Cartridges are voltage interchangeable.• Industry common cavity.• Unitized, molded coil design.• Continuous duty rated solenoid.• Optional coil voltages and terminations.• Optional “I” Coil: Weatherproof, Thermal Shock, Immersion Safe.

Nominal Flow 8 GPM (30 LPM) Rated Operating Pressure 4000 PSI (276 bar)Typical Internal Leakage (150 SSU) 10 cu in/min (164 ml/min) per pathViscosity Range 36 to 3000 SSU (3 to 647 cSt)Filtration ISO 18/16/13Media Operating Temp. Range -40° to 250°F (-40° to 120°C)Weight .43 lbs (.20 kg)Operating Fluid Media General Purpose Hydraulic FluidCartridge Torque Requirements 35 ft-lbs (47.5 Nm)Coil Nut Torque Requirements 4-6 ft-lbs (5.4-8.1 Nm)Cavity DELTA 4WCavity Tools Kit (form tool, reamer, tap) 40500002Seal Kit 21191214

0

50

100

150

200

0 6 842 10 12Flow (GPM)

0

5

10

0 5 10 15 20 25

Pres

sure

Dro

p (P

SI)

30 35 40 45Flow (LPM)

Pres

sure

Dro

p (b

ar)

Port 1 to 2 (eng) Port 4 to 3 (eng)

0

50

100

150

200

0 2 4 6 8 10 12Flow (GPM)

0

5

10

0 5 10

Pre

ssur

e D

rop

(PS

I)

15 20 25 30 4035 45Flow (LPM)

Pre

ssur

e D

rop

(bar

)

Port 3 to 2 (de-eng) Port 4 to 1 (de-eng)

Actual Test Data (Cartridge Only)

PERFORMANCE HYDRAULIC SYMBOL

VALVE SPECIFICATIONS

Uses “L” Coils.Pressure differential between ports should not exceed 3000 PSI.

4

1

2

3

Page 143: SOLENOID OPERATED DIRECTIONAL … 1000 38 69 7/8-14 DE-S2F SD18 2 WAY 2 POSITION NORMALLY CLOSED POPPET VALVES SLID PRATD DIRTIAL TRLS Page SD3 Via Malavolti, 36 • 41122 Modena •

SOLENOID OPERATED DIRECTIONAL CONTROLS

Page SD153

Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512 mail: [email protected] • www.tecnord.com

4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 mail: [email protected] • www.delta-power.com

WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken without independent study, evaluation, and testing for suitability.

W 2

0 /

2018

Note: Aluminum, NOT durability rated for 4000 PSI. Consult factory for body options.

DIMENSIONS

ORDERING INFORMATIONApproximate Coil Weight: .68 lbs (.31 kg)

OPTIONS BODIESBuna Standard 00 Blank Without BodyViton Standard V0 N 1/4 NPTF Ports

S #6 SAE Ports

VOLTAGE06 6 VDC12 12 VDC24 24 VDC36 36 VDC48 48 VDC25 24 VAC11 120 VAC22 220 VAC

“L” COIL TERMINATION 44 440 VAC(All DC Except as Noted)

IMMERSION PROOF “L” TYPEDL Double Lead SS Single Spade IA “I” Coil AMP Superseal - IntegralDT Deutsch on Leads DT04-2P DS Double Spade ID “I” Coil Deutsch - Integral DT04-2PML Metri-Pack on Leads HC DIN 43650 (Hirschmann) - (AC&DC) IJ “I” Coil AMP Jr. Timer - IntegralPL Packard on Leads CL Conduit Lead - (AC Only) IM “I” Coil Metri-Pack - IntegralWL Weatherpack on Leads DI Deutsch - Integral DT04-2P

HG-S4D – – – –

DE

LTA P

OW

ER

1.56 [39.6]

1.83 [46.6]

.75 [19.1]

HEX NUT

2.63 [66.8]

.50 [12.7]

2.44 [61.9]

7/8-14 UNF-2A THREAD

1.00 [25.4] HEX

SEE COILDATA FORTERMINATIONS

DE

LTA P

OW

ER

1.56 [39.6]

1.50 [38.1]

.81 [20.6]

2.59 [65.7]

.63 [15.9]

2.00 [50.8]

1.38 [34.9]

2.88 [73.0]

3.25 [82.6]

2.50 [63.5]

2.25 [57.2]

1.25 [31.8]

.13 [3.2]

.281 [7.14] DIA2X

#6 SAE PORTS4X

BODY WEIGHT: .99 lbs (.45 kg)

Page 144: SOLENOID OPERATED DIRECTIONAL … 1000 38 69 7/8-14 DE-S2F SD18 2 WAY 2 POSITION NORMALLY CLOSED POPPET VALVES SLID PRATD DIRTIAL TRLS Page SD3 Via Malavolti, 36 • 41122 Modena •

SOLENOID OPERATED DIRECTIONAL CONTROLS

Page SD154

Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512 mail: [email protected] • www.tecnord.com

4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 mail: [email protected] • www.delta-power.com

WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken without independent study, evaluation, and testing for suitability.

W 20 / 2018

DG-S4E DIRECT ACTING SPOOL, 4 WAY 2 POSITION, SERIES/PARALLEL

DESCRIPTION10 size, 7/8-14 thread, “Delta” series, solenoid operated, 4 way 2 position, series/parallel spool valve.

OPERATIONWhen de-energized the DG-S4E allows flow from (2) and (1), and (3) to (4). When energized the valve allows flow (2) to (4) and blocks the flow at (1) and (3).OPERATION OF MANUAL OVERRIDE OPTION: to override, pull knob out. On the detented version, after pulling knob out twist 180 degrees and release. The valve will remain in that position.

FEATURES • Hardened parts for long life.• Efficient wet-armature construction.• Cartridges are voltage interchangeable.• Manual override option.• Industry common cavity.• Unitized, molded coil design.• Continuous duty rated solenoid.• Optional coil voltages and terminations.• Optional “I” Coil: Weatherproof, Thermal Shock, Immersion Safe.

Nominal Flow 6 GPM (23 LPM)Rated Operating Pressure 3000 PSI (207 bar)Typical Internal Leakage (150 SSU) 5 cu in/min (82 ml/min) per pathViscosity Range 36 to 3000 SSU (3 to 647 cSt)Filtration ISO 18/16/13Media Operating Temp. Range -40° to 250°F (-40° to 120°C)Weight .31 lbs (.14 kg)Operating Fluid Media General Purpose Hydraulic FluidCartridge Torque Requirements 30 ft-lbs (40.6 Nm)Coil Nut Torque Requirements 4-6 ft-lbs (5.4-8.1 Nm)Cavity DELTA 4WCavity Tools Kit (form tool, reamer, tap) 40500002Seal Kit 21191214

0

50

100

150

200

0 62 84 100

5

Pre

ssur

e D

rop

(PS

I)

10

0 10 3020Flow (LPM)

Pre

ssur

e D

rop

(bar

)

Flow (GPM)

Port 2 to 1 (de-eng) Port 3 to 4 (de-eng) Port 2 to 4 (eng)

Actual Test Data (Cartridge Only)

VALVE SPECIFICATIONS

For higher pressures see HG-S4E. Operational shift limit, 6 GPM (23 LPM). For shift performance consult chart.

PERFORMANCE

HYDRAULIC SYMBOL

4

1

2

3

Page 145: SOLENOID OPERATED DIRECTIONAL … 1000 38 69 7/8-14 DE-S2F SD18 2 WAY 2 POSITION NORMALLY CLOSED POPPET VALVES SLID PRATD DIRTIAL TRLS Page SD3 Via Malavolti, 36 • 41122 Modena •

SOLENOID OPERATED DIRECTIONAL CONTROLS

Page SD155

Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512 mail: [email protected] • www.tecnord.com

4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 mail: [email protected] • www.delta-power.com

WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken without independent study, evaluation, and testing for suitability.

W 2

0 /

2018

DIMENSIONS

ORDERING INFORMATIONApproximate Coil Weight: .74 lbs (.33 kg)

OPTIONS BODIESBuna Standard 00 Blank Without BodyViton Standard V0 N 1/4 NPTF PortsBuna, Override 0M S #6 SAE PortsViton, Override VM

Buna, Override, Non-detent B1Viton, Override, Non-detent V1 VOLTAGE

06 6 VDC12 12 VDC24 24 VDC36 36 VDC48 48 VDC25 24 VAC11 120 VAC22 220 VAC44 440 VAC

“D” COIL TERMINATION(All DC Except as Noted)

IMMERSION PROOF “D” TYPEDL Double Lead SS Single Spade IA “I” Coil AMP Superseal - IntegralDT Deutsch on Leads DT04-2P DS Double Spade ID “I” Coil - Deutsch - Integral DT04-2PML Metri-Pack on Leads HC DIN 43650 (Hirschmann) - (AC&DC) IJ “I” Coil AMP Jr. Timer - IntegralPL Packard on Leads CL Conduit Lead - (AC Only) IM “I” Coil - Metri-Pack - IntegralWL Weatherpack on Leads DI Deutsch - Integral DT04-2P

DG-S4E – – – –

DE

LTA PO

WE

R

1.56 [39.6]

1.83 [46.6]

.75 [19.1]

HEX NUT

3.35 [85.1] 2.31

[58.8]

2.44 [61.9]

.22 [5.6]

1.00 [25.4] HEX

7/8-14 UNF-2A

7/16-20 UNF-2ATHREAD

MANUAL OVERRIDE

STANDARD

SEE COILDATA FORTERMINATIONS

DE

LTA P

OW

ER

1.56 [39.6]

1.50 [38.1]

.81 [20.6]

2.27 [57.8]

.63 [15.9]

2.00 [50.8]

3.25 [82.6]

1.38 [34.9]

2.88 [73.0]

2.50 [63.5]

2.25 [57.2]

1.25 [31.8]

.13 [3.2]

.28 [7.1] DIA.MTG. SLOTS2X

#6 SAE PORTS4X

BODY WEIGHT: .99 lbs (.45 kg)

Page 146: SOLENOID OPERATED DIRECTIONAL … 1000 38 69 7/8-14 DE-S2F SD18 2 WAY 2 POSITION NORMALLY CLOSED POPPET VALVES SLID PRATD DIRTIAL TRLS Page SD3 Via Malavolti, 36 • 41122 Modena •

SOLENOID OPERATED DIRECTIONAL CONTROLS

Page SD156

Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512 mail: [email protected] • www.tecnord.com

4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 mail: [email protected] • www.delta-power.com

WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken without independent study, evaluation, and testing for suitability.

W 20 / 2018

HG-S4E DIRECT ACTING SPOOL, 4 WAY 2 POSITION, SERIES/PARALLEL

DESCRIPTION“High Pressure” 10 size, 7/8-14 thread, “Delta” series, solenoid operated, 4 way 2 position series/parallel spool valve.

OPERATIONWhen de-energized the HG-S4E allows flow from (1) to (2) and from (3) to (4). When energized the valve allows flow from (2) to (4) and blocks flow at (1) and (3).

FEATURES • Hardened parts for long life.• Efficient wet-armature construction.• Cartridges are voltage interchangeable.• Industry common cavity.• Unitized, molded coil design.• Continuous duty rated solenoid.• Optional coil voltages and terminations.• Optional “I” Coil: Weatherproof, Thermal Shock, Immersion Safe.

Nominal Flow 8 GPM (30 LPM) Rated Operating Pressure 4000 PSI (276 bar)Typical Internal Leakage (150 SSU) 10 cu in/min (164 ml/min) per pathViscosity Range 36 to 3000 SSU (3 to 647 cSt)Filtration ISO 18/16/13Media Operating Temp. Range -40° to 250°F (-40° to 120°C)Weight .43 lbs (.20 kg)Operating Fluid Media General Purpose Hydraulic FluidCartridge Torque Requirements 30 ft-lbs (40,6 Nm)Coil Nut Torque Requirements 4-6 ft-lbs (5.4-8.1 Nm)Cavity DELTA 4WCavity Tools Kit (form tool, reamer, tap) 40500002Seal Kit 21191214

0

50

100

150

0

200

2 4 6 8 10 12Flow (GPM)

0

5

10

0 10

Pre

ssur

e D

rop

(PS

I)

20 30 40Flow (LPM)

Pre

ssur

e D

rop

(bar

)

Port 2 to 1 (de-eng) Port 3 to 4 (de-eng) Port 2 to 4 (eng)

Actual Test Data (Cartridge Only)

VALVE SPECIFICATIONSPERFORMANCE

HYDRAULIC SYMBOL

4

1

2

3

Uses “L” Coils.Pressure differential between ports should not exceed 3000 PSI.

Page 147: SOLENOID OPERATED DIRECTIONAL … 1000 38 69 7/8-14 DE-S2F SD18 2 WAY 2 POSITION NORMALLY CLOSED POPPET VALVES SLID PRATD DIRTIAL TRLS Page SD3 Via Malavolti, 36 • 41122 Modena •

SOLENOID OPERATED DIRECTIONAL CONTROLS

Page SD157

Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512 mail: [email protected] • www.tecnord.com

4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 mail: [email protected] • www.delta-power.com

WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken without independent study, evaluation, and testing for suitability.

W 2

0 /

2018

Note: Aluminum, NOT durability rated for 4000 PSI. Consult factory for body options.

DIMENSIONS

ORDERING INFORMATIONApproximate Coil Weight: .68 lbs (.31 kg)

OPTIONS BODIESBuna Standard 00 Blank Without BodyViton Standard V0 N 1/4 NPTF Ports

S #6 SAE Ports

VOLTAGE06 6 VDC12 12 VDC24 24 VDC36 36 VDC48 48 VDC25 24 VAC11 120 VAC22 220 VAC

“L” COIL TERMINATION 44 440 VAC(All DC Except as Noted)

IMMERSION PROOF “L” TYPEDL Double Lead SS Single Spade IA “I” Coil AMP Superseal - IntegralDT Deutsch on Leads DT04-2P DS Double Spade ID “I” Coil Deutsch - Integral DT04-2PML Metri-Pack on Leads HC DIN 43650 (Hirschmann) - (AC&DC) IJ “I” Coil AMP Jr. Timer - IntegralPL Packard on Leads CL Conduit Lead - (AC Only) IM “I” Coil Metri-Pack - IntegralWL Weatherpack on Leads DI Deutsch - Integral DT04-2P

HG-S4E – – – –

DE

LTA P

OW

ER

1.56 [39.6]

1.83 [46.6]

.75 [19.1]

HEX NUT

2.63 [66.8]

.50 [12.7]

2.44 [61.9]

7/8-14 UNF-2A THREAD

1.00 [25.4] HEX

SEE COILDATA FORTERMINATIONS

DE

LTA P

OW

ER

1.56 [39.6]

1.50 [38.1]

.81 [20.6]

2.59 [65.7]

.63 [15.9]

2.00 [50.8]

1.38 [34.9]

2.88 [73.0]

3.25 [82.6]

2.50 [63.5]

2.25 [57.2]

1.25 [31.8]

.13 [3.2]

.281 [7.14] DIA2X

#6 SAE PORTS4X

BODY WEIGHT: .99 lbs (.45 kg)

Page 148: SOLENOID OPERATED DIRECTIONAL … 1000 38 69 7/8-14 DE-S2F SD18 2 WAY 2 POSITION NORMALLY CLOSED POPPET VALVES SLID PRATD DIRTIAL TRLS Page SD3 Via Malavolti, 36 • 41122 Modena •

SOLENOID OPERATED DIRECTIONAL CONTROLS

Page SD158

Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512 mail: [email protected] • www.tecnord.com

4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 mail: [email protected] • www.delta-power.com

WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken without independent study, evaluation, and testing for suitability.

W 20 / 2018

HV-S4E DIRECT ACTING SPOOL, 4 WAY 2 POSITION, SERIES/PARALLEL

DESCRIPTION“High pressure” 12 size, 1 1/16-12 thread, “Tecnord” series, solenoid operated, 4 way 2 position, series/parallel flow spool valve.

OPERATIONWhen de-energized the HV-S4E allows flow from (2) to (1) and from (3) to (4). When energized the valve allows flow from (2) to (4) and blocks flow at (1) to (3).

FEATURES • Hardened parts for long life.• Efficient wet-armature construction.• Cartridges are voltage interchangeable.• Industry common cavity.• Unitized, molded coil design.• Continuous duty rated solenoid.• Optional coil voltages and terminations.

Nominal Flow 15 GPM (57 LPM) from (2) to (4) 8 GPM (30 LPM) from (4) to (2)Rated Operating Pressure 5000 PSI (345 bar) Typical Internal Leakage (150 SSU) 8 cu in/min (131 ml/min) per pathViscosity Range 36 to 3000 SSU (3 to 647 cSt)Filtration ISO 18/16/13Media Operating Temp. Range -40° to 250°F (-40° to 120°C)Weight 1.09 lbs (.49 kg)Operating Fluid Media General Purpose Hydraulic FluidCartridge Torque Requirements 70 ft-lbs (94.9 Nm)Coil Nut Torque Requirements 5-7 ft-lbs (6.8-9.5 Nm) MaximumCavity TECNORD 4WCavity Tools Kit (form tool, reamer, tap) 40500035Seal Kit 21191309

Actual Test Data (Cartridge Only)

VALVE SPECIFICATIONSPERFORMANCE

HYDRAULIC SYMBOL

4

1

2

3

Page 149: SOLENOID OPERATED DIRECTIONAL … 1000 38 69 7/8-14 DE-S2F SD18 2 WAY 2 POSITION NORMALLY CLOSED POPPET VALVES SLID PRATD DIRTIAL TRLS Page SD3 Via Malavolti, 36 • 41122 Modena •

SOLENOID OPERATED DIRECTIONAL CONTROLS

Page SD159

Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512 mail: [email protected] • www.tecnord.com

4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 mail: [email protected] • www.delta-power.com

WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken without independent study, evaluation, and testing for suitability.

W 2

0 /

2018

DIMENSIONS

ORDERING INFORMATIONApproximate Coil Weight: .89 lbs (.41 kg)

OPTIONS BODIESBuna Standard 00 Blank Without BodyViton Standard V0 S #10 SAE Ports

VOLTAGE06 6 VDC

“T” COIL TERMINATION 12 12 VDC(All DC Except as Noted) 24 24 VDC

Double Lead DL 36 36 VDCDeutsch on Leads DT 48 48 VDC

Metri-Pack on Leads ML 25 24 VACPackard on Leads PL 11 120 VAC

Weatherpack on Leads WL 22 220 VACDouble Spade DS

DIN 43650 (Hirschmann) - (AC&DC) HC

HV-S4E – – – –

DELTA POWER

2.09 [53.2]

1.00 [25.4]

HEX NUT1.80

[45.7]

3.90 [99.0]

1.23 [31.3]

3.80 [96.4]

1 1/16-12 UN2A THREAD

1.25 [31.7] HEX

SEE COIL DATAFOR TERMINATIONS

DELTA POWER

3.82 [97.0]

1.80 [45.7]

.88 [22.4]

1.76 [44.7]

1.15 [29.2]

2.12 [53.9]

4.75 [120.7]

1.15 [29.2]

3.09 [78.5]

4.15 [105.4]

3.00 [76.2]

2.30 [58.4]

1.50 [38.1]

.35 [8.9]

.41 [10.3] DIA.MTG. HOLES2X

#10 SAE PORTS4X

BODY WEIGHT: 5.08 lbs (2.3 kg)

Page 150: SOLENOID OPERATED DIRECTIONAL … 1000 38 69 7/8-14 DE-S2F SD18 2 WAY 2 POSITION NORMALLY CLOSED POPPET VALVES SLID PRATD DIRTIAL TRLS Page SD3 Via Malavolti, 36 • 41122 Modena •

SOLENOID OPERATED DIRECTIONAL CONTROLS

Page SD160

Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512 mail: [email protected] • www.tecnord.com

4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 mail: [email protected] • www.delta-power.com

WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken without independent study, evaluation, and testing for suitability.

W 20 / 2018

DG-S4F DIRECT ACTING SPOOL, 4 WAY 2 POSITION, ENERGIZED TO BLOCK

DESCRIPTION10 size, 7/8-14 thread, “Delta” series, solenoid operated, 4 way 2 position, energized to block spool valve.

OPERATIONWhen de-energized the DG-S4F allows flow from (2) and (1), and from (3) to (4). When energized the valve blocks flow at all ports.OPERATION OF MANUAL OVERRIDE OPTION: to override, pull knob out. On the detented version, after pulling knob out twist 180 degrees and release. The valve will remain in that position.

FEATURES • Hardened parts for long life.• Efficient wet-armature construction.• Cartridges are voltage interchangeable.• Manual override option.• Industry common cavity.• Unitized, molded coil design.• Continuous duty rated solenoid.• Optional coil voltages and terminations.• Optional “I” Coil: Weatherproof, Thermal Shock, Immersion Safe.

Nominal Flow 6 GPM (23 LPM)Rated Operating Pressure 3000 PSI (207 bar)Typical Internal Leakage (150 SSU) 5 cu in/min (82 ml/min) per pathViscosity Range 36 to 3000 SSU (3 to 647 cSt)Filtration ISO 18/16/13Media Operating Temp. Range -40° to 250°F (-40° to 120°C)Weight .31 lbs (.14 kg)Operating Fluid Media General Purpose Hydraulic FluidCartridge Torque Requirements 30 ft-lbs (40.6 Nm)Coil Nut Torque Requirements 4-6 ft-lbs (5.4-8.1 Nm)Cavity DELTA 4WCavity Tools Kit (form tool, reamer, tap) 40500002Seal Kit 21191214

0

50

100

150

200

0 2 4 6 8 10 12

Pre

ssur

e D

rop

(PS

I)

0

5

10

Flow (GPM)

0 10 3020 40

Pre

ssur

e D

rop

(bar

)

Flow (LPM)

Port 2 to 1 (de-eng) Port 3 to 4 (de-eng)

Actual Test Data (Cartridge Only)

VALVE SPECIFICATIONS

For higher pressures see HG-S4F. Operational shift limit, 6 GPM (23 LPM). For shift performance consult chart.

PERFORMANCE

HYDRAULIC SYMBOL

4

1

2

3

Page 151: SOLENOID OPERATED DIRECTIONAL … 1000 38 69 7/8-14 DE-S2F SD18 2 WAY 2 POSITION NORMALLY CLOSED POPPET VALVES SLID PRATD DIRTIAL TRLS Page SD3 Via Malavolti, 36 • 41122 Modena •

SOLENOID OPERATED DIRECTIONAL CONTROLS

Page SD161

Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512 mail: [email protected] • www.tecnord.com

4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 mail: [email protected] • www.delta-power.com

WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken without independent study, evaluation, and testing for suitability.

W 2

0 /

2018

DIMENSIONS

ORDERING INFORMATIONApproximate Coil Weight: .74 lbs (.33 kg)

OPTIONS BODIESBuna Standard 00 Blank Without BodyViton Standard V0 N 1/4 NPTF PortsBuna, Override 0M S #6 SAE PortsViton, Override VM

Buna, Override, Non-detent B1Viton, Override, Non-detent V1 VOLTAGE

06 6 VDC12 12 VDC24 24 VDC36 36 VDC48 48 VDC25 24 VAC11 120 VAC22 220 VAC44 440 VAC

“D” COIL TERMINATION(All DC Except as Noted)

IMMERSION PROOF “D” TYPEDL Double Lead SS Single Spade IA “I” Coil AMP Superseal - IntegralDT Deutsch on Leads DT04-2P DS Double Spade ID “I” Coil - Deutsch - Integral DT04-2PML Metri-Pack on Leads HC DIN 43650 (Hirschmann) - (AC&DC) IJ “I” Coil AMP Jr. Timer - IntegralPL Packard on Leads CL Conduit Lead - (AC Only) IM “I” Coil - Metri-Pack - IntegralWL Weatherpack on Leads DI Deutsch - Integral DT04-2P

DG-S4F – – – –

DE

LTA PO

WE

R

1.56 [39.6]

1.83 [46.6]

.75 [19.1]

HEX NUT

3.35 [85.1] 2.31

[58.8]

2.44 [61.9]

.22 [5.6]

1.00 [25.4] HEX

7/8-14 UNF-2A

7/16-20 UNF-2ATHREAD

MANUAL OVERRIDE

STANDARD

SEE COILDATA FORTERMINATIONS

DE

LTA P

OW

ER

1.56 [39.6]

1.50 [38.1]

.81 [20.6]

2.27 [57.8]

.63 [15.9]

2.00 [50.8]

3.25 [82.6]

1.38 [34.9]

2.88 [73.0]

2.50 [63.5]

2.25 [57.2]

1.25 [31.8]

.13 [3.2]

.28 [7.1] DIA.MTG. SLOTS2X

#6 SAE PORTS4X

BODY WEIGHT: .99 lbs (.45 kg)

Page 152: SOLENOID OPERATED DIRECTIONAL … 1000 38 69 7/8-14 DE-S2F SD18 2 WAY 2 POSITION NORMALLY CLOSED POPPET VALVES SLID PRATD DIRTIAL TRLS Page SD3 Via Malavolti, 36 • 41122 Modena •

SOLENOID OPERATED DIRECTIONAL CONTROLS

Page SD162

Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512 mail: [email protected] • www.tecnord.com

4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 mail: [email protected] • www.delta-power.com

WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken without independent study, evaluation, and testing for suitability.

W 20 / 2018

HG-S4F DIRECT ACTING SPOOL, 4 WAY 2 POSITION, ENERGIZED TO BLOCK

DESCRIPTION“High Pressure” 10 size, 7/8-14 thread, “Delta” series, solenoid operated, 4 way 2 position energized to block spool valve.

OPERATIONWhen de-energized the HG-S4F allows flow from (2) to (1) and from (3) to (4). When energized the valve blocks flow at all ports.

FEATURES • Hardened parts for long life.• Efficient wet-armature construction.• Cartridges are voltage interchangeable.• Industry common cavity.• Unitized, molded coil design.• Continuous duty rated solenoid.• Optional coil voltages and terminations.• Optional “I” Coil: Weatherproof, Thermal Shock, Immersion Safe.

Nominal Flow 6 GPM (23 LPM) Rated Operating Pressure 4000 PSI (276 bar)Typical Internal Leakage (150 SSU) 10 cu in/min (164 ml/min) per pathViscosity Range 36 to 3000 SSU (3 to 647 cSt)Filtration ISO 18/16/13Media Operating Temp. Range -40° to 250°F (-40° to 120°C)Weight .44 lbs (.20 kg)Operating Fluid Media General Purpose Hydraulic FluidCartridge Torque Requirements 35 ft-lbs (47.5 Nm)Coil Nut Torque Requirements 4-6 ft-lbs (5.4-8.1 Nm)Cavity DELTA 4WCavity Tools Kit (form tool, reamer, tap) 40500002Seal Kit 21191214

0

50

100

150

200

250

0 2 4 86 10 12

Pre

ssur

e D

rop

(PS

I)

0

5

10

Flow (GPM)

15

0 01 02 03 40

Pre

ssur

e D

rop

(bar

)

Flow (LPM)

Port 2 to 1 (de-eng) Port 3 to 4 (de-eng)

Actual Test Data (Cartridge Only)

VALVE SPECIFICATIONSPERFORMANCE

HYDRAULIC SYMBOL

4

1

2

3

Uses “L” Coils.Pressure differential between ports should not exceed 3000 PSI.

Page 153: SOLENOID OPERATED DIRECTIONAL … 1000 38 69 7/8-14 DE-S2F SD18 2 WAY 2 POSITION NORMALLY CLOSED POPPET VALVES SLID PRATD DIRTIAL TRLS Page SD3 Via Malavolti, 36 • 41122 Modena •

SOLENOID OPERATED DIRECTIONAL CONTROLS

Page SD163

Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512 mail: [email protected] • www.tecnord.com

4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 mail: [email protected] • www.delta-power.com

WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken without independent study, evaluation, and testing for suitability.

W 2

0 /

2018

Note: Aluminum, NOT durability rated for 4000 PSI. Consult factory for body options.

DIMENSIONS

ORDERING INFORMATIONApproximate Coil Weight: .68 lbs (.31 kg)

OPTIONS BODIESBuna Standard 00 Blank Without BodyViton Standard V0 N 1/4 NPTF Ports

S #6 SAE Ports

VOLTAGE06 6 VDC12 12 VDC24 24 VDC36 36 VDC48 48 VDC25 24 VAC11 120 VAC22 220 VAC

“L” COIL TERMINATION 44 440 VAC(All DC Except as Noted)

IMMERSION PROOF “L” TYPEDL Double Lead SS Single Spade IA “I” Coil AMP Superseal - IntegralDT Deutsch on Leads DT04-2P DS Double Spade ID “I” Coil Deutsch - Integral DT04-2PML Metri-Pack on Leads HC DIN 43650 (Hirschmann) - (AC&DC) IJ “I” Coil AMP Jr. Timer - IntegralPL Packard on Leads CL Conduit Lead - (AC Only) IM “I” Coil Metri-Pack - IntegralWL Weatherpack on Leads DI Deutsch - Integral DT04-2P

HG-S4F – – – –

DE

LTA P

OW

ER

1.56 [39.6]

1.83 [46.6]

.75 [19.1]

HEX NUT

2.63 [66.8]

.50 [12.7]

2.44 [61.9]

7/8-14 UNF-2A THREAD

1.00 [25.4] HEX

SEE COILDATA FORTERMINATIONS

DE

LTA P

OW

ER

1.56 [39.6]

1.50 [38.1]

.81 [20.6]

2.59 [65.7]

.63 [15.9]

2.00 [50.8]

1.38 [34.9]

2.88 [73.0]

3.25 [82.6]

2.50 [63.5]

2.25 [57.2]

1.25 [31.8]

.13 [3.2]

.281 [7.14] DIA2X

#6 SAE PORTS4X

BODY WEIGHT: .99 lbs (.45 kg)

Page 154: SOLENOID OPERATED DIRECTIONAL … 1000 38 69 7/8-14 DE-S2F SD18 2 WAY 2 POSITION NORMALLY CLOSED POPPET VALVES SLID PRATD DIRTIAL TRLS Page SD3 Via Malavolti, 36 • 41122 Modena •

SOLENOID OPERATED DIRECTIONAL CONTROLS

Page SD164

W 20 / 2018

Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512 mail: [email protected] • www.tecnord.com

4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 mail: [email protected] • www.delta-power.com

WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken without independent study, evaluation, and testing for suitability.

4W3P SPOOL GPM PSI LPM BAR CAVITY MODEL PAGE

3 3000 11 207 3/4-16 VQ-S4M SD166

5 3000 19 207 3/4-16 PQ-S4M SD168

6.5 3000 25 207 7/8-14 DG-S4M SD170

5 3000 19 207 3/4-16 PQ-S4N SD172

6 3000 23 207 7/8-14 DG-S4N SD174

2.5 3000 9.5 207 3/4-16 VQ-S4R SD176

3 3000 11 207 3/4-16 PQ-S4R SD178

3 3000 11 207 3/4-16 PQ-S4O SD180

8 3000 30 207 7/8-14 DG-S4O SD182

5 3000 19 207 3/4-16 PQ-S4T SD184

3.5 3000 13.2 207 3/4-16 VQ-S4Q SD186

5 3000 19 207 3/4-16 PQ-S4P SD188

8 3000 30 207 7/8-14 DG-S4P SD190

6 3000 23 207 3/4-16 PQ-S4Q SD192

6 3000 23 207 7/8-14 DG-S4S SD194

4 WAY 3 POSITION SPOOL VALVES

Page 155: SOLENOID OPERATED DIRECTIONAL … 1000 38 69 7/8-14 DE-S2F SD18 2 WAY 2 POSITION NORMALLY CLOSED POPPET VALVES SLID PRATD DIRTIAL TRLS Page SD3 Via Malavolti, 36 • 41122 Modena •

SOLENOID OPERATED DIRECTIONAL CONTROLS

Page SD165

W 2

0 /

2018

Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512 mail: [email protected] • www.tecnord.com

4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 mail: [email protected] • www.delta-power.com

WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken without independent study, evaluation, and testing for suitability.

Typical application for the S4O and S4T “Open Center” valve is a bidirectional fluid motor control with coasting.Typical application for the S4Q and S4P “Closed Center” valve is a parallel circuit for cylinder control.Typical application for the S4N and S4R “Tandem Center” valve is a series circuit with power beyond.Typical application for the S4M “Figure Four” valve is coasting in a fluid motor control circuit.Typical application for the S4S “Scotch Center” valve is to vent the pilot side of load holding application.

TYPICAL SCHEMATIC

SOLENOID OPERATED DIRECTIONAL CONTROLS

(3) (1)

(2) (4)(2) (4)

(3) (1)

(3) (1)

(2) (4)

(3) (1)

(2) (4)

(2) (4)

(3) (1)

(3) (1)

(2) (4)

(2) (4)

(3) (1)

Page 156: SOLENOID OPERATED DIRECTIONAL … 1000 38 69 7/8-14 DE-S2F SD18 2 WAY 2 POSITION NORMALLY CLOSED POPPET VALVES SLID PRATD DIRTIAL TRLS Page SD3 Via Malavolti, 36 • 41122 Modena •

SOLENOID OPERATED DIRECTIONAL CONTROLS

Page SD168

Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512 mail: [email protected] • www.tecnord.com

4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 mail: [email protected] • www.delta-power.com

WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken without independent study, evaluation, and testing for suitability.

W 20 / 2018

PQ-S4M DIRECT ACTING SPOOL, 4 WAY 3 POSITION, MOTOR CENTER

DESCRIPTION8 size, 3/4-16 thread, “Power” series, solenoid operated, 4 way 3 position, motor center spool valve.

OPERATIONWhen de-energized the PQ-S4M allows flow between (1), (3) and (4), blocks flow at (2). When outer coil (S1) is energized the valve allows flow from (2) to (1) and from (3) to (4). When inner coil (S2) is energized the valve allows flow from (2) to (3) and from (1) to (4).OPERATION OF MANUAL OVERRIDE OPTION: push Only Override - Spring biased in neutral center position, when pushed the valve shifts in the (S2) direction.

FEATURES • Hardened parts for long life.• Efficient wet-armature construction.• Cartridges are voltage interchangeable.• Industry common cavity.• Optional manual “push only” override.• Unitized, molded coil design.• Continuous duty rated solenoid.• Optional coil voltages and terminations.

Nominal Flow 5 GPM (19 LPM)Rated Operating Pressure 3000 PSI (207 bar)Typical Internal Leakage (150 SSU) 5 cu in/min (82 ml/min) per pathViscosity Range 36 to 3000 SSU (3 to 647 cSt)Filtration ISO 18/16/13Media Operating Temp. Range -40° to 250°F (-40° to 120°C)Weight .42 lbs (.19 kg)Operating Fluid Media General Purpose Hydraulic FluidCartridge Torque Requirements 25 ft-lbs (34 Nm)Coil Nut Torque Requirements 4-6 ft-lbs (5.4-8.1 Nm)Cavity POWER 4WCavity Tools Kit (form tool, reamer, tap) 40500029Seal Kit 21191108

0

50

100

150

200

0 2 4 6Flow (GPM)

0

5

10

0 5 10 2015

Pre

ssur

e D

rop

(PS

I)

Flow (L PM)

Pre

ssur

e D

rop

(bar

)

Port 2 to 1 (eng S1) Port 3 to 4 (eng S1)

0

50

100

150

200

0 2 4 6Flow (GPM)

0

5

10

0

Pre

ssur

e D

rop

(PS

I)

5 10 15 20Flow (LPM)

Pre

ssur

e D

rop

(bar

)

Port 1 to 4 (eng S2) Port 2 to 3 (eng S2)

0

50

100

150

200

0 2 4 6Flow (GPM)

0

5

10

0 5 10 2015

Pre

ssur

e D

rop

(PS

I)

Flow (L PM)

Pre

ssur

e D

rop

(bar

)

Port 2 to 1 (eng S1) Port 3 to 4 (eng S1)

0

50

100

150

200

0 2 4 6Flow (GPM)

0

5

10

0

Pre

ssur

e D

rop

(PS

I)

5 10 15 20Flow (LPM)

Pre

ssur

e D

rop

(bar

)

Port 1 to 4 (eng S2) Port 2 to 3 (eng S2)

Actual Test Data (Cartridge Only)

PERFORMANCE

Uses “D” Delta coil. Flow rating based on maximum differential load of 1000 PSI. “OP” override is a push only nondetented button that actuates (S2) direction.

HYDRAULIC SYMBOL

VALVE SPECIFICATIONS

4

1

2

3

Page 157: SOLENOID OPERATED DIRECTIONAL … 1000 38 69 7/8-14 DE-S2F SD18 2 WAY 2 POSITION NORMALLY CLOSED POPPET VALVES SLID PRATD DIRTIAL TRLS Page SD3 Via Malavolti, 36 • 41122 Modena •

SOLENOID OPERATED DIRECTIONAL CONTROLS

Page SD169

Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512 mail: [email protected] • www.tecnord.com

4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 mail: [email protected] • www.delta-power.com

WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken without independent study, evaluation, and testing for suitability.

W 2

0 /

2018

DIMENSIONS

ORDERING INFORMATIONApproximate Coil Weight: .74 lbs (.33 kg)

OPTIONS BODIESBuna Standard 00 Blank Without BodyViton Standard V0 N 1/4 NPTF Ports

Buna, Push Only Override 0P S #6 SAE PortsViton, Push Only Override VP

VOLTAGE06 6 VDC12 12 VDC24 24 VDC36 36 VDC48 48 VDC25 24 VAC11 120 VAC22 220 VAC44 440 VAC

“D” COIL TERMINATION(All DC Except as Noted)

DL Double Lead SS Single SpadeDT Deutsch on Leads DT04-2P DS Double SpadeML Metri-Pack on Leads HC DIN 43650 (Hirschmann) - (AC&DC)PL Packard on Leads CL Conduit Lead - (AC Only)WL Weatherpack on Leads DI Deutsch - Integral DT04-2P

PQ-S4M – – – –

DE

LTA P

OW

ER

CO

.

1.25 [31.7]

1.54 [39.1]

.56 [14.2]

HEX NUT

5.90 [149.9]

4.85 [123.1]

2.10 [53.3]

.65 [16.5] 3/4-16 UNF

2A THREAD

.88 [22.2] HEX

S1

S2

"PUSH ONLY" OVERRIDE

STANDARD

SEE COIL DATAFOR TERMINATIONS.

4.82 [122.3]

.59 [15.1]

1.72 [43.7]

2.75 [69.9]

.25 [6.4]

1.16 [29.4]

3.00 [76.2]

2.25 [57.2]

1.75 [44.5]

1.13 [28.6]

.25 [6.4]

1.25 [31.8]

.63 [15.9]

1.25 [31.7]

#6 SAE PORTS4X

.28 [7.1] DIA.MTG. HOLES2X

BODY WEIGHT: .67 lbs (.30 kg)

DE

LTA P

OW

ER

CO

.

Page 158: SOLENOID OPERATED DIRECTIONAL … 1000 38 69 7/8-14 DE-S2F SD18 2 WAY 2 POSITION NORMALLY CLOSED POPPET VALVES SLID PRATD DIRTIAL TRLS Page SD3 Via Malavolti, 36 • 41122 Modena •

SOLENOID OPERATED DIRECTIONAL CONTROLS

Page SD170

Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512 mail: [email protected] • www.tecnord.com

4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 mail: [email protected] • www.delta-power.com

WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken without independent study, evaluation, and testing for suitability.

W 20 / 2018

DG-S4M DIRECT ACTING SPOOL, 4 WAY 3 POSITION, MOTOR CENTER

DESCRIPTION10 size, 7/8-14 thread, “Delta” series, solenoid operated, 4 way 3 position, motor center spool valve.

OPERATIONWhen de-energized the DG-S4M block the flow at (2) and allows flow between (1), (3) and (4). When outer coil (S1) is energized the valve allows flow from (2) to (1) and from (3) to (4). When inner coil (S2) is energized the valve allows flow from (2) to (3) and from (1) to (4).OPERATION OF MANUAL OVERRIDE OPTION: Bidirectional Override - Spring biased in neutral center position, when pushed the valve shifts in the (S2) direction, when pulled the valve shifts in the (S1) direction.Push Only Override - Spring biased in neutral center position, when pushed the valve shifts in the (S2) direction.

FEATURES • Hardened parts for long life.• Efficient wet-armature construction.• Cartridges are voltage interchangeable.• Manual override option. • Industry common cavity.• Unitized, molded coil design.• Continuous duty rated solenoid.• Optional coil voltages and terminations.• Optional “I” Coil: Weatherproof, Thermal Shock, Immersion Safe.

Nominal Flow 6.5 GPM (25 LPM)Rated Operating Pressure 3000 PSI (207 bar)Typical Internal Leakage (150 SSU) 5 cu in/min (82 ml/min) per pathViscosity Range 36 to 3000 SSU (3 to 647 cSt)Filtration ISO 18/16/13Media Operating Temp. Range -40° to 250°F (-40° to 120°C)Weight .51 lbs (.23 kg)Operating Fluid Media General Purpose Hydraulic FluidCartridge Torque Requirements 30 ft-lbs (40.6 Nm)Coil Nut Torque Requirements 4-6 ft-lbs (5.4-8.1 Nm)Cavity DELTA 4WCavity Tools Kit (form tool, reamer, tap) 40500002Seal Kit 21191214

0

25

50

75

100

125

150

0 42 86Flow (G PM)

0

5

10

0 5 10 15 20 25 30

Pre

ssur

e D

rop

(PS

I)

Flow (LPM)

Pre

ssur

e D

rop

(bar

)

Port 2 to 1 (eng S1) P ort 3 to 4 (eng S1)

0

25

50

75

100

125

0 2

150

4 6 80

5

Pre

ssur

e D

rop

(PS

I)

10

Flow (GPM)

0 5 10 15 20 25 30

Pre

ssur

e D

rop

(bar

)

Flow (LPM)

Port 1 to 4 (eng S2) Port 2 to 3 (eng S2)

0

25

50

75

100

125

150

0 42 86Flow (G PM)

0

5

10

0 5 10 15 20 25 30

Pre

ssur

e D

rop

(PS

I)

Flow (LPM)

Pre

ssur

e D

rop

(bar

)

Port 2 to 1 (eng S1) P ort 3 to 4 (eng S1)

0

25

50

75

100

125

0 2

150

4 6 80

5

Pre

ssur

e D

rop

(PS

I)

10

Flow (GPM)

0 5 10 15 20 25 30

Pre

ssur

e D

rop

(bar

)

Flow (LPM)

Port 1 to 4 (eng S2) Port 2 to 3 (eng S2)

Actual Test Data (Cartridge Only)

PERFORMANCE

Uses “L” Coil. Flow rating is at 1000 PSID maximum differential loading.

HYDRAULIC SYMBOL

VALVE SPECIFICATIONS

4

1

2

3

Page 159: SOLENOID OPERATED DIRECTIONAL … 1000 38 69 7/8-14 DE-S2F SD18 2 WAY 2 POSITION NORMALLY CLOSED POPPET VALVES SLID PRATD DIRTIAL TRLS Page SD3 Via Malavolti, 36 • 41122 Modena •

SOLENOID OPERATED DIRECTIONAL CONTROLS

Page SD171

Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512 mail: [email protected] • www.tecnord.com

4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 mail: [email protected] • www.delta-power.com

WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken without independent study, evaluation, and testing for suitability.

W 2

0 /

2018

DIMENSIONS

ORDERING INFORMATIONApproximate Coil Weight: .68 lbs (.31 kg)

OPTIONS BODIESBuna Standard 00 Blank Without BodyViton Standard V0 N 1/4 NPTF PortsBuna, Override 0M S #6 SAE PortsViton, Override VM

Buna, Push Only Override 0PViton, Push Only Override VP

VOLTAGE06 6 VDC12 12 VDC24 24 VDC36 36 VDC48 48 VDC25 24 VAC11 120 VAC22 220 VAC

“L” COIL TERMINATION 44 440 VAC(All DC Except as Noted)

IMMERSION PROOF “L” TYPEDL Double Lead SS Single Spade IA “I” Coil AMP Superseal - IntegralDT Deutsch on Leads DT04-2P DS Double Spade ID “I” Coil Deutsch - Integral DT04-2PML Metri-Pack on Leads HC DIN 43650 (Hirschmann) - (AC&DC) IJ “I” Coil AMP Jr. Timer - IntegralPL Packard on Leads CL Conduit Lead - (AC Only) IM “I” Coil Metri-Pack - IntegralWL Weatherpack on Leads DI Deutsch - Integral DT04-2P

DG-S4M – – – –

DE

LTA P

OW

ER

CO

.

PUSH ONLY OVERRIDE

STANDARD

1" HEX [25.4]

7/8-14 UNF-2A THREAD

5.82 [147.8]

4.85 [123.1]

2.44 [61.9]

.56 [14.3]

1.56 [39.6]

1.83 [46.6]

.75 [19.0]

HEX NUT

SEE COIL DATAFOR TREMINATIONS

Page 160: SOLENOID OPERATED DIRECTIONAL … 1000 38 69 7/8-14 DE-S2F SD18 2 WAY 2 POSITION NORMALLY CLOSED POPPET VALVES SLID PRATD DIRTIAL TRLS Page SD3 Via Malavolti, 36 • 41122 Modena •

SOLENOID OPERATED DIRECTIONAL CONTROLS

Page SD172

Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512 mail: [email protected] • www.tecnord.com

4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 mail: [email protected] • www.delta-power.com

WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken without independent study, evaluation, and testing for suitability.

W 20 / 2018

PQ-S4N DIRECT ACTING SPOOL, 4 WAY 3 POSITION, TANDEM CENTER

DESCRIPTION8 size, 3/4-16 thread, “Power” series, solenoid operated, 4 way 3 position, tandem center spool valve.

OPERATIONWhen de-energized the PQ-S4N allows flow between (2) and (4), blocks flow at (1) and (3). When outer coil (S1) is energized the valve allows flow from (2) to (3) and from (1) to (4). When inner coil (S2) is energized the valve allows flow from (2) to (1) and from (3) to (4).OPERATION OF MANUAL OVERRIDE OPTION: push Only Override - Spring biased in neutral center position, when pushed the valve shifts in the (S2) direction.

FEATURES • Hardened parts for long life.• Efficient wet-armature construction.• Cartridges are voltage interchangeable.• Industry common cavity.• Optional manual “push only” override.• Unitized, molded coil design.• Continuous duty rated solenoid.• Optional coil voltages and terminations.

Nominal Flow 5 GPM (19 LPM)Rated Operating Pressure 3000 PSI (207 bar)Typical Internal Leakage (150 SSU) 5 cu in/min (82 ml/min) per pathViscosity Range 36 to 3000 SSU (3 to 647 cSt)Filtration ISO 18/16/13Media Operating Temp. Range -40° to 250°F (-40° to 120°C)Weight .42 lbs (.19 kg)Operating Fluid Media General Purpose Hydraulic FluidCartridge Torque Requirements 25 ft-lbs (34 Nm)Coil Nut Torque Requirements 4-6 ft-lbs (5.4-8.1 Nm)Cavity POWER 4WCavity Tools Kit (form tool, reamer, tap) 40500029Seal Kit 21191108

0

50

100

150

200

250

10 32 54Flow (GPM)

0

5

10

15

0 5 10 15

Pre

ssur

e D

rop

(PS

I)

Flow (LPM)

Pre

ssur

e D

rop

(bar

)

Port 2 to 4 (de-eng) Port 1 to 4 (eng S1) Port 2 to 3 ( eng S1)

0

50

100

150

200

250

210 4 53Flow (GPM)

0

5

10

15

0 5 15 10

Pre

ssur

e D

rop

(PS

I)

Flow (LPM)

Pre

ssur

e D

rop

(bar

)

Port 2 to 1 (eng S2) Port 3 to 4 (eng S2)

0

50

100

150

200

250

10 32 54Flow (GPM)

0

5

10

15

0 5 10 15

Pre

ssur

e D

rop

(PS

I)

Flow (LPM)

Pre

ssur

e D

rop

(bar

)

Port 2 to 4 (de-eng) Port 1 to 4 (eng S1) Port 2 to 3 ( eng S1)

0

50

100

150

200

250

210 4 53Flow (GPM)

0

5

10

15

0 5 15 10

Pre

ssur

e D

rop

(PS

I)

Flow (LPM)

Pre

ssur

e D

rop

(bar

)

Port 2 to 1 (eng S2) Port 3 to 4 (eng S2)

Actual Test Data (Cartridge Only)

PERFORMANCE HYDRAULIC SYMBOL

VALVE SPECIFICATIONS

Uses “D” Delta coil. “OP” override is a push only non-detented button that actuates (S2) direction.

4

1

2

3

Page 161: SOLENOID OPERATED DIRECTIONAL … 1000 38 69 7/8-14 DE-S2F SD18 2 WAY 2 POSITION NORMALLY CLOSED POPPET VALVES SLID PRATD DIRTIAL TRLS Page SD3 Via Malavolti, 36 • 41122 Modena •

SOLENOID OPERATED DIRECTIONAL CONTROLS

Page SD173

Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512 mail: [email protected] • www.tecnord.com

4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 mail: [email protected] • www.delta-power.com

WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken without independent study, evaluation, and testing for suitability.

W 2

0 /

2018

DIMENSIONS

ORDERING INFORMATIONApproximate Coil Weight: .74 lbs (.33 kg)

OPTIONS BODIESBuna Standard 00 Blank Without BodyViton Standard V0 N 1/4 NPTF Ports

Buna, Push Only Override 0P S #6 SAE PortsViton, Push Only Override VP

VOLTAGE06 6 VDC12 12 VDC24 24 VDC36 36 VDC48 48 VDC25 24 VAC11 120 VAC22 220 VAC44 440 VAC

“D” COIL TERMINATION(All DC Except as Noted)

DL Double Lead SS Single SpadeDT Deutsch on Leads DT04-2P DS Double SpadeML Metri-Pack on Leads HC DIN 43650 (Hirschmann) - (AC&DC)PL Packard on Leads CL Conduit Lead - (AC Only)WL Weatherpack on Leads DI Deutsch - Integral DT04-2P

PQ-S4N – – – –

12 VD

C

HY

DR

AU

LIC C

O.

DD

L12

4.88 [123.9]

2.11 [53.6]

5.93 [150.6]

.65 [16.5]

SEE COIL DATAFOR TERMINATIONS.

"PUSH ONLY" OVERRIDE

STANDARD

S1

S2

.56 [14.2]

HEX NUT

1.83 [46.6]

3/4-16 UNF2A THREAD

.88 [22.2] HEX

1.56 [39.6]

Page 162: SOLENOID OPERATED DIRECTIONAL … 1000 38 69 7/8-14 DE-S2F SD18 2 WAY 2 POSITION NORMALLY CLOSED POPPET VALVES SLID PRATD DIRTIAL TRLS Page SD3 Via Malavolti, 36 • 41122 Modena •

SOLENOID OPERATED DIRECTIONAL CONTROLS

Page SD174

Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512 mail: [email protected] • www.tecnord.com

4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 mail: [email protected] • www.delta-power.com

WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken without independent study, evaluation, and testing for suitability.

W 20 / 2018

DG-S4N DIRECT ACTING SPOOL, 4 WAY 3 POSITION, TANDEM CENTER

DESCRIPTION10 size, 7/8-14 thread, “Delta” series, solenoid operated, 4 way 3 position, tandem center spool valve.

OPERATIONWhen de-energized the DG-S4N allows flow between (2) and (4), and blocks flow at (1) and (3). When outer coil (S1) is energized the valve allows flow from (2) to (3) and from (1) to (4). When inner coil (S2) is energized the valve allows flow from (2) to (1) and from (3) to (4).OPERATION OF MANUAL OVERRIDE OPTION: Bidirectional Override - Spring biased in neutral center position, when pushed the valve shifts in the (S2) direction, when pulled the valve shifts in the (S1) direction.Push Only Override - Spring biased in neutral center position, when pushed the valve shifts in the (S2) direction.

FEATURES • Hardened parts for long life.• Efficient wet-armature construction.• Cartridges are voltage interchangeable.• Manual override option. • Industry common cavity.• Unitized, molded coil design.• Continuous duty rated solenoid.• Optional coil voltages and terminations.• Optional “I” Coil: Weatherproof, Thermal Shock, Immersion Safe.

Nominal Flow 6 GPM (23 LPM)Rated Operating Pressure 3000 PSI (207 bar)Typical Internal Leakage (150 SSU) 5 cu in/min (82 ml/min) per pathViscosity Range 36 to 3000 SSU (3 to 647 cSt)Filtration ISO 18/16/13Media Operating Temp. Range -40° to 250°F (-40° to 120°C)Weight .52 lbs (.23 kg)Operating Fluid Media General Purpose Hydraulic FluidCartridge Torque Requirements 30 ft-lbs (40.6 Nm)Coil Nut Torque Requirements 4-6 ft-lbs (5.4-8.1 Nm)Cavity DELTA 4WCavity Tools Kit (form tool, reamer, tap) 40500002Seal Kit 21191214

0

50

100

150

200

250

300

350

0 2 64 8

Pres

sure

Dro

p (P

SI)

Flow (GPM)

0

5

10

15

20

0 5 10 15 20 25 30

Pres

sure

Dro

p (b

ar)

Flow (LPM)

Port 2 to 4 (de-eng) Port 1 to 4 (eng S1) Port 2 to 3 (eng S1)

0

50

100

150

200

2

250

0 864Flow (GPM)

0

5

10

Pres

sure

Dro

p (P

SI)

0

15

5 10 15 20 25 30Flow (LPM)

Pres

sure

Dro

p (b

ar)

Port 2 to 1 (eng S2) Port 3 to 4 (eng S2)

0

50

100

150

200

250

300

350

0 2 64 8

Pres

sure

Dro

p (P

SI)

Flow (GPM)

0

5

10

15

20

0 5 10 15 20 25 30

Pres

sure

Dro

p (b

ar)

Flow (LPM)

Port 2 to 4 (de-eng) Port 1 to 4 (eng S1) Port 2 to 3 (eng S1)

0

50

100

150

200

2

250

0 864Flow (GPM)

0

5

10

Pres

sure

Dro

p (P

SI)

0

15

5 10 15 20 25 30Flow (LPM)

Pres

sure

Dro

p (b

ar)

Port 2 to 1 (eng S2) Port 3 to 4 (eng S2)

Actual Test Data (Cartridge Only)

PERFORMANCE

Uses “L” Coils.

HYDRAULIC SYMBOL

VALVE SPECIFICATIONS

4

1

2

3

Page 163: SOLENOID OPERATED DIRECTIONAL … 1000 38 69 7/8-14 DE-S2F SD18 2 WAY 2 POSITION NORMALLY CLOSED POPPET VALVES SLID PRATD DIRTIAL TRLS Page SD3 Via Malavolti, 36 • 41122 Modena •

SOLENOID OPERATED DIRECTIONAL CONTROLS

Page SD175

Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512 mail: [email protected] • www.tecnord.com

4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 mail: [email protected] • www.delta-power.com

WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken without independent study, evaluation, and testing for suitability.

W 2

0 /

2018

DIMENSIONS

ORDERING INFORMATIONApproximate Coil Weight: .68 lbs (.31 kg)

OPTIONS BODIESBuna Standard 00 Blank Without BodyViton Standard V0 N 1/4 NPTF Ports

Buna, Push Only Override 0P S #6 SAE PortsViton, Push Only Override VP

VOLTAGE06 6 VDC12 12 VDC24 24 VDC36 36 VDC48 48 VDC25 24 VAC11 120 VAC22 220 VAC

“L” COIL TERMINATION 44 440 VAC(All DC Except as Noted)

IMMERSION PROOF “L” TYPEDL Double Lead SS Single Spade IA “I” Coil AMP Superseal - IntegralDT Deutsch on Leads DT04-2P DS Double Spade ID “I” Coil Deutsch - Integral DT04-2PML Metri-Pack on Leads HC DIN 43650 (Hirschmann) - (AC&DC) IJ “I” Coil AMP Jr. Timer - IntegralPL Packard on Leads CL Conduit Lead - (AC Only) IM “I” Coil Metri-Pack - IntegralWL Weatherpack on Leads DI Deutsch - Integral DT04-2P

DG-S4N – – – –

DE

LTA P

OW

ER

CO

.

PUSH ONLY OVERRIDE

STANDARD

1" HEX [25.4]

7/8-14 UNF-2A THREAD

5.82 [147.8]

4.85 [123.1]

2.44 [61.9]

.56 [14.3]

1.56 [39.6]

1.83 [46.6]

.75 [19.0]

HEX NUT

SEE COIL DATAFOR TREMINATIONS

Page 164: SOLENOID OPERATED DIRECTIONAL … 1000 38 69 7/8-14 DE-S2F SD18 2 WAY 2 POSITION NORMALLY CLOSED POPPET VALVES SLID PRATD DIRTIAL TRLS Page SD3 Via Malavolti, 36 • 41122 Modena •

SOLENOID OPERATED DIRECTIONAL CONTROLS

Page SD176

Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512 mail: [email protected] • www.tecnord.com

4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 mail: [email protected] • www.delta-power.com

WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken without independent study, evaluation, and testing for suitability.

W 20 / 2018

VQ-S4R DIRECT ACTING SPOOL, 4 WAY 3 POSITION, TANDEM CENTER

DESCRIPTIONLow Profile 8 size, 3/4-16 thread, “Power” series, solenoid operated, 4W3P, tandem center spool valve.

OPERATIONWhen de-energized the VQ-S4R allows flow between (2) and (4), ports (1) and (3) are blocked. When outer coil (S1) is energized the valve allows flow from (2) to (3) and from (1) to (4). When inner coil (S2) is energized the valve allows flow from (2) to (1) and from (3) to (4).

FEATURES • Hardened parts for long life.• Efficient wet-armature construction.• Cartridges are voltage interchangeable.• Industry common cavity.• Unitized, molded coil design.• Continuous duty rated solenoid.• Optional coil voltages and terminations.• Optional “I” Coil: Weatherproof, Thermal Shock, Immersion Safe.

0

20

40

60

80

100

120

140

160

0 1 2 3 4 5

Pres

sure

Dro

p (P

SI)

0

2

4

6

8

Flow (GPM)

10

0 3 6 9 12 1815

Pres

sure

Dro

p (B

AR)

Flow (LPM)

Port 2 to 3 (s1 eng) Port 1 to 4 (s1 eng)

0

20

40

60

80

100

120

140

160

10 2 3 4Flow (GPM)

0

2

4

6

8

Pre

ssur

e D

rop

( PS

I)

10

0 3 6 9 12 15Flow (LPM)

Pre

ssur

e D

rop

(BA

R)

Port 2 to 1 (s2 eng) Port 3 to 4 (s2 eng)

0

20

40

60

80

100

120

140

160

0 1 2 3 4 5

Pres

sure

Dro

p (P

SI)

0

2

4

6

8

Flow (GPM)

10

0 3 6 9 12 1815

Pres

sure

Dro

p (B

AR)

Flow (LPM)

Port 2 to 3 (s1 eng) Port 1 to 4 (s1 eng)

0

20

40

60

80

100

120

140

160

10 2 3 4Flow (GPM)

0

2

4

6

8

Pre

ssur

e D

rop

( PS

I)

10

0 3 6 9 12 15Flow (LPM)

Pre

ssur

e D

rop

(BA

R)

Port 2 to 1 (s2 eng) Port 3 to 4 (s2 eng)

Pres

sure

Dro

p (B

AR)

Pres

sure

Dro

p (P

SI)

0

20

40

60

80

100

120

140

160

180

10 432 5

Pres

sure

Dro

p (P

SI)

0

Flow (GPM)

2

4

6

8

10

12

0 5 10 15Flow (LPM)

Port 2 to 1 (s1 eng) Port 3 to 4 (s1 eng)

0

20

40

60

80

100

120

140

0 1 2 3 4 50

2

Flow (GPM)

4

6

8

0 2 4 6 8 0 1 2 1 14 6 1 18

Pres

sure

Dro

p (B

AR)

Flow (LPM)

Port 2 to 3 (s2 eng) Port 1 to 4 (s2 eng)

Nominal Flow 2.5 GPM (9.5 LPM) Rated Operating Pressure 3000 PSI (207 bar)Typical Internal Leakage (150 SSU) 15 cu in/min (245 ml/min) per pathViscosity Range 36 to 3000 SSU (3 to 647 cSt)Filtration ISO 18/16/13Media Operating Temp. Range -40° to 250°F (-40° to 120°C)Weight .42 lbs (.19 kg)Operating Fluid Media General Purpose Hydraulic FluidCartridge Torque Requirements 25 ft-lbs (34 Nm)Coil Nut Torque Requirements 4-6 ft-lbs (5.4-8.1 Nm)Cavity POWER 4WCavity Form Tool (Finishing) 40500029Seal Kit 21191108

Actual Test Data (Cartridge Only)

PERFORMANCE HYDRAULIC SYMBOL

VALVE SPECIFICATIONS

4

1

2

3

Page 165: SOLENOID OPERATED DIRECTIONAL … 1000 38 69 7/8-14 DE-S2F SD18 2 WAY 2 POSITION NORMALLY CLOSED POPPET VALVES SLID PRATD DIRTIAL TRLS Page SD3 Via Malavolti, 36 • 41122 Modena •

SOLENOID OPERATED DIRECTIONAL CONTROLS

Page SD177

Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512 mail: [email protected] • www.tecnord.com

4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 mail: [email protected] • www.delta-power.com

WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken without independent study, evaluation, and testing for suitability.

W 2

0 /

2018

DIMENSIONS

ORDERING INFORMATIONApproximate Coil Weight: .74 lbs (.33 kg)

OPTIONS BODIESBuna Standard 00 Blank Without BodyViton Standard V0 N 1/4 NPTF Ports

S #6 SAE Ports

VOLTAGE06 6 VDC12 12 VDC24 24 VDC36 36 VDC48 48 VDC25 24 VAC11 120 VAC22 220 VAC

“P” COIL TERMINATION 44 440 VAC(All DC Except as Noted)

IMMERSION PROOF “P” TYPEDL Double Lead SS Single Spade IA “I” Coil AMP Superseal - IntegralDT Deutsch on Leads DT04-2P DS Double Spade ID “I” Coil Deutsch - Integral DT04-2PML Metri-Pack on Leads HC DIN 43650 (Hirschmann) - (AC&DC) IJ “I” Coil AMP Jr. Timer - IntegralPL Packard on Leads CL Conduit Lead - (AC Only) IM “I” Coil Metri-Pack - IntegralWL Weatherpack on Leads DI Deutsch - Integral DT04-2P

VQ-S4R – – – –

Page 166: SOLENOID OPERATED DIRECTIONAL … 1000 38 69 7/8-14 DE-S2F SD18 2 WAY 2 POSITION NORMALLY CLOSED POPPET VALVES SLID PRATD DIRTIAL TRLS Page SD3 Via Malavolti, 36 • 41122 Modena •

SOLENOID OPERATED DIRECTIONAL CONTROLS

Page SD178

Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512 mail: [email protected] • www.tecnord.com

4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 mail: [email protected] • www.delta-power.com

WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken without independent study, evaluation, and testing for suitability.

W 20 / 2018

PQ-S4R DIRECT ACTING SPOOL, 4 WAY 3 POSITION, TANDEM CENTER

DESCRIPTION8 size, 3/4-16 thread, “Power” series, solenoid operated, 4 way 3 position, tandem center spool valve.

OPERATIONWhen de-energized the PQ-S4R allows flow between (2) and (4), ports (1) and (3) are blocked. When outer coil (S1) is energized the valve allows flow from (2) to (3) and from (1) to (4). When inner coil (S2) is energized the valve allows flow from (2) to (1) and from (3) to (4).OPERATION OF MANUAL OVERRIDE OPTION: push Only Override - Spring biased in neutral center position, when pushed the valve shifts in the (S2) direction.

FEATURES • Hardened parts for long life.• Efficient wet-armature construction.• Cartridges are voltage interchangeable.• Industry common cavity.• Optional manual “push only” override.• Unitized, molded coil design.• Continuous duty rated solenoid.• Optional coil voltages and terminations.

Nominal Flow 3 GPM (11 LPM)Rated Operating Pressure 3000 PSI (207 bar)Typical Internal Leakage (150 SSU) 5 cu in/min (82 ml/min) per pathViscosity Range 36 to 3000 SSU (3 to 647 cSt)Filtration ISO 18/16/13Media Operating Temp. Range -40° to 250°F (-40° to 120°C)Weight .42 lbs (.19 kg)Operating Fluid Media General Purpose Hydraulic FluidCartridge Torque Requirements 25 ft-lbs (34 Nm)Coil Nut Torque Requirements 4-6 ft-lbs (5.4-8.1 Nm)Cavity POWER 4WCavity Tools Kit (form tool, reamer, tap) 40500029Seal Kit 21191108

Flow (LPM)

0

25

50

75

100

10 2 3

Pre

ssur

e D

rop

(PS

I)

0

5

0 5

Flow (GPM)

10

Pre

ssur

e D

rop

(bar

)

Port 1 to 4 (eng S1) Port 2 to 3 (eng S1)

0

25

50

75

100

10 32

Pre

ssur

e D

rop

(PS

I)

0

Flow (GPM)

5

50 10

Pre

ssur

e D

rop

(bar

)

Flow (LPM)

Port 2 to 4 (de-eng) Port 2 to 1 (eng S2) Port 3 to 4 (eng S2)

Flow (LPM)

0

25

50

75

100

10 2 3

Pre

ssur

e D

rop

(PS

I)

0

5

0 5

Flow (GPM)

10

Pre

ssur

e D

rop

(bar

)

Port 1 to 4 (eng S1) Port 2 to 3 (eng S1)

0

25

50

75

100

10 32

Pre

ssur

e D

rop

(PS

I)

0

Flow (GPM)

5

50 10

Pre

ssur

e D

rop

(bar

)

Flow (LPM)

Port 2 to 4 (de-eng) Port 2 to 1 (eng S2) Port 3 to 4 (eng S2)

Actual Test Data (Cartridge Only)

PERFORMANCE

Uses “P” Power coil. For higher flow see PQ-S4N. “OP” override is a push only non-detented button that actuates (S2) direction. For “I” coil environmental protection option, consult factory for special build configuration per Delta Standard 40295013.

HYDRAULIC SYMBOL

VALVE SPECIFICATIONS

4

1

2

3

Page 167: SOLENOID OPERATED DIRECTIONAL … 1000 38 69 7/8-14 DE-S2F SD18 2 WAY 2 POSITION NORMALLY CLOSED POPPET VALVES SLID PRATD DIRTIAL TRLS Page SD3 Via Malavolti, 36 • 41122 Modena •

SOLENOID OPERATED DIRECTIONAL CONTROLS

Page SD179

Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512 mail: [email protected] • www.tecnord.com

4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 mail: [email protected] • www.delta-power.com

WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken without independent study, evaluation, and testing for suitability.

W 2

0 /

2018

DIMENSIONS

PQ-S4R – – – –

ORDERING INFORMATIONApproximate Coil Weight: .42 lbs (.19 kg)

OPTIONS BODIESBuna Standard 00 Blank Without BodyViton Standard V0 N 1/4 NPTF Ports

Buna, Push Only Override 0P S #6 SAE PortsViton, Push Only Override VP

VOLTAGE06 6 VDC12 12 VDC24 24 VDC36 36 VDC48 48 VDC25 24 VAC11 120 VAC22 220 VAC

“P” COIL TERMINATION 44 440 VAC(All DC Except as Noted)

IMMERSION PROOF “D” TYPEDL Double Lead SS Single Spade IA “I” Coil AMP Superseal - IntegralDT Deutsch on Leads DT04-2P DS Double Spade ID “I” Coil Deutsch - Integral DT04-2PML Metri-Pack on Leads HC DIN 43650 (Hirschmann) - (AC&DC) IJ “I” Coil AMP Jr. Timer - IntegralPL Packard on Leads CL Conduit Lead - (AC Only) IM “I” Coil Metri-Pack - IntegralWL Weatherpack on Leads DI Deutsch - Integral DT04-2P

DE

LTA P

OW

ER

CO

.

1.25 [31.7]

1.54 [39.1]

.56 [14.2]

HEX NUT

5.90 [149.9]

4.85 [123.1]

2.10 [53.3]

.65 [16.5] 3/4-16 UNF

2A THREAD

.88 [22.2] HEX

S1

S2

"PUSH ONLY" OVERRIDE

STANDARD

SEE COIL DATAFOR TERMINATIONS.

4.82 [122.3]

.59 [15.1]

1.72 [43.7]

2.75 [69.9]

.25 [6.4]

1.16 [29.4]

3.00 [76.2]

2.25 [57.2]

1.75 [44.5]

1.13 [28.6]

.25 [6.4]

1.25 [31.8]

.63 [15.9]

1.25 [31.7]

#6 SAE PORTS4X

.28 [7.1] DIA.MTG. HOLES2X

BODY WEIGHT: .67 lbs (.30 kg)

DE

LTA P

OW

ER

CO

.

Page 168: SOLENOID OPERATED DIRECTIONAL … 1000 38 69 7/8-14 DE-S2F SD18 2 WAY 2 POSITION NORMALLY CLOSED POPPET VALVES SLID PRATD DIRTIAL TRLS Page SD3 Via Malavolti, 36 • 41122 Modena •

SOLENOID OPERATED DIRECTIONAL CONTROLS

Page SD182

Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512 mail: [email protected] • www.tecnord.com

4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 mail: [email protected] • www.delta-power.com

WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken without independent study, evaluation, and testing for suitability.

W 20 / 2018

DG-S4O DIRECT ACTING SPOOL, 4 WAY 3 POSITION, OPEN CENTER

DESCRIPTION10 size, 7/8-14 thread, “Delta” series, solenoid operated, 4 way 3 position, open center spool valve.

OPERATIONWhen de-energized the DG-S4O is open to all ports, all pressures are relieved. When outer coil (S1) is energized the valve allows flow from (2) to (1) and from (3) to (4). When inner coil (S2) is energized the valve allows flow from (2) to (3) and from (1) to (4).OPERATION OF MANUAL OVERRIDE OPTION: Bidirectional Override - Spring biased in neutral center position, when pushed the valve shifts in the (S2) direction, when pulled the valve shifts in the (S1) direction.Push Only Override - Spring biased in neutral center position, when pushed the valve shifts in the (S2) direction.

FEATURES • Hardened parts for long life.• Efficient wet-armature construction.• Cartridges are voltage interchangeable.• Manual override option. • Industry common cavity.• Unitized, molded coil design.• Continuous duty rated solenoid.• Optional coil voltages and terminations.• Optional “I” Coil: Weatherproof, Thermal Shock, Immersion Safe.

Nominal Flow 8 GPM (30 LPM)Rated Operating Pressure 3000 PSI (207 bar)Typical Internal Leakage (150 SSU) 5 cu in/min (82 ml/min) per pathViscosity Range 36 to 3000 SSU (3 to 647 cSt)Filtration ISO 18/16/13Media Operating Temp. Range -40° to 250°F (-40° to 120°C)Weight .50 lbs (.23 kg)Operating Fluid Media General Purpose Hydraulic FluidCartridge Torque Requirements 30 ft-lbs (40.6 Nm)Coil Nut Torque Requirements 4-6 ft-lbs (5.4-8.1 Nm)Cavity DELTA 4WCavity Tools Kit (form tool, reamer, tap) 40500002Seal Kit 21191214

0

25

50

75

100

125

150

0 2 84 6Flow (GPM)

0

5

10

0 5 10 15 20 25 30

Pre

ssur

e D

rop

(PS

I)

Pre

ssur

e D

rop

(bar

)

Flow (LPM)

Port 2 to 1 (eng S1) Port 3 to 4 (eng S1)

0

50

100

150

4

200

0 2 6 8Flow (G PM)

0

5

10

0 5

Pre

ssur

e D

rop

(PS

I)

10 2015 25 30Flow (LPM)

Pre

ssur

e D

rop

(bar

)

Port 2 to 4 (de-eng) Port 1 to 4 (e ng S2) Port 2 to 3 (eng S2)

0

25

50

75

100

125

150

0 2 84 6Flow (GPM)

0

5

10

0 5 10 15 20 25 30

Pre

ssur

e D

rop

(PS

I)

Pre

ssur

e D

rop

(bar

)

Flow (LPM)

Port 2 to 1 (eng S1) Port 3 to 4 (eng S1)

0

50

100

150

4

200

0 2 6 8Flow (G PM)

0

5

10

0 5

Pre

ssur

e D

rop

(PS

I)

10 2015 25 30Flow (LPM)

Pre

ssur

e D

rop

(bar

)

Port 2 to 4 (de-eng) Port 1 to 4 (e ng S2) Port 2 to 3 (eng S2)

Actual Test Data (Cartridge Only)

PERFORMANCE

Uses “L” Coils.

HYDRAULIC SYMBOL

VALVE SPECIFICATIONS

4

1

2

3

Page 169: SOLENOID OPERATED DIRECTIONAL … 1000 38 69 7/8-14 DE-S2F SD18 2 WAY 2 POSITION NORMALLY CLOSED POPPET VALVES SLID PRATD DIRTIAL TRLS Page SD3 Via Malavolti, 36 • 41122 Modena •

SOLENOID OPERATED DIRECTIONAL CONTROLS

Page SD183

Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512 mail: [email protected] • www.tecnord.com

4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 mail: [email protected] • www.delta-power.com

WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken without independent study, evaluation, and testing for suitability.

W 2

0 /

2018

DIMENSIONS

ORDERING INFORMATIONApproximate Coil Weight: .68 lbs (.31 kg)

OPTIONS BODIESBuna Standard 00 Blank Without BodyViton Standard V0 N 1/4 NPTF PortsBuna, Override 0M S #6 SAE PortsViton, Override VM

Buna, Push Only Override 0PViton, Push Only Override VP

VOLTAGE06 6 VDC12 12 VDC24 24 VDC36 36 VDC48 48 VDC25 24 VAC11 120 VAC22 220 VAC

“L” COIL TERMINATION 44 440 VAC(All DC Except as Noted)

IMMERSION PROOF “L” TYPEDL Double Lead SS Single Spade IA “I” Coil AMP Superseal - IntegralDT Deutsch on Leads DT04-2P DS Double Spade ID “I” Coil Deutsch - Integral DT04-2PML Metri-Pack on Leads HC DIN 43650 (Hirschmann) - (AC&DC) IJ “I” Coil AMP Jr. Timer - IntegralPL Packard on Leads CL Conduit Lead - (AC Only) IM “I” Coil Metri-Pack - IntegralWL Weatherpack on Leads DI Deutsch - Integral DT04-2P

DG-S4O – – – –D

ELTA

PO

WE

R C

O.

BI-DIRECTIONAL OVERRIDE

PUSH ONLY OVERRIDE

STANDARD

1.00 [25.4] HEX

7/8-14 UNF-2A THREAD

7.12 [180.9]

5.82 [147.8]

4.85 [123.1]

2.44 [61.9]

.56 [14.3]

1.56 [39.6]

1.83 [46.6]

.75 [19.0]

HEX NUT

SEE COIL DATAFOR TREMINATIONS

DE

LTA P

OW

ER

CO

>

BODY WEIGHT: .98 lbs (.45 kg)

S2

S1

3.25 [82.6]

.63 [15.9]

2.00 [50.8]

4.77 [121.3]

.13 [3.2]

2.25 [57.2]

1.38 [34.9]

2.88 [73.0]

2.50 [63.5]

.81 [20.6]1.50

[38.1]

1.25 [31.8]

#6 SAE PORTS4X

.28 [7.1] DIA.MTG. SLOTS2X

Page 170: SOLENOID OPERATED DIRECTIONAL … 1000 38 69 7/8-14 DE-S2F SD18 2 WAY 2 POSITION NORMALLY CLOSED POPPET VALVES SLID PRATD DIRTIAL TRLS Page SD3 Via Malavolti, 36 • 41122 Modena •

SOLENOID OPERATED DIRECTIONAL CONTROLS

Page SD184

Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512 mail: [email protected] • www.tecnord.com

4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 mail: [email protected] • www.delta-power.com

WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken without independent study, evaluation, and testing for suitability.

W 20 / 2018

PQ-S4T DIRECT ACTING SPOOL, 4 WAY 3 POSITION, OPEN CENTER

DESCRIPTION8 size, 3/4-16 thread, “Power” series, solenoid operated, 4 way 3 position, open center spool valve.

OPERATIONWhen de-energized the PQ-S4T is open to all ports, all pressures are relieved. When outer coil (S1) is energized the valve allows flow from (2) to (1) and from (3) to (4). When inner coil (S2) is energized the valve allows flow from (2) to (3) and from (1) to (4).OPERATION OF MANUAL OVERRIDE OPTION: push Only Override - Spring biased in neutral center position, when pushed the valve shifts in the (S2) direction.

FEATURES • Hardened parts for long life.• Efficient wet-armature construction.• Cartridges are voltage interchangeable.• Industry common cavity.• Optional manual “push only” override.• Unitized, molded coil design.• Continuous duty rated solenoid.• Optional coil voltages and terminations.

Nominal Flow 5 GPM (19 LPM)Rated Operating Pressure 3000 PSI (207 bar)Typical Internal Leakage (150 SSU) 5 cu in/min (82 ml/min) per pathViscosity Range 36 to 3000 SSU (3 to 647 cSt)Filtration ISO 18/16/13Media Operating Temp. Range -40° to 250°F (-40° to 120°C)Weight .42 lbs (.19 kg)Operating Fluid Media General Purpose Hydraulic FluidCartridge Torque Requirements 25 ft-lbs (34 Nm)Coil Nut Torque Requirements 4-6 ft-lbs (5.4-8.1 Nm)Cavity POWER 4WCavity Tools Kit (form tool, reamer, tap) 40500029Seal Kit 21191108

0

50

100

150

200

250

420 6Flow (GPM)

0

5

10

15

0 5

Pre

ssur

e D

rop

(PS

I)

1510 20Flow (LPM)

Pre

ssur

e D

rop

(bar

)

Port 2 to 1 (eng S1) Port 3 to 4 (eng S1)

0

50

100

150

200

250

0 2 64Flow (GPM)

0

5

10

15

0

Pre

ssur

e D

rop

(PS

I)

5 10 15 20Flow (LPM)

Pre

ssur

e D

rop

(bar

)

Port 2 to 4 (de-eng) Port 1 to 4 (eng S2) Port 2 to 3 ( eng S2)

0

50

100

150

200

250

420 6Flow (GPM)

0

5

10

15

0 5

Pre

ssur

e D

rop

(PS

I)

1510 20Flow (LPM)

Pre

ssur

e D

rop

(bar

)

Port 2 to 1 (eng S1) Port 3 to 4 (eng S1)

0

50

100

150

200

250

0 2 64Flow (GPM)

0

5

10

15

0

Pre

ssur

e D

rop

(PS

I)

5 10 15 20Flow (LPM)

Pre

ssur

e D

rop

(bar

)

Port 2 to 4 (de-eng) Port 1 to 4 (eng S2) Port 2 to 3 ( eng S2)

Actual Test Data (Cartridge Only)

PERFORMANCE

Uses “D” Delta coil “OP” override is a push only non-detented button that actuates (S2) direction.

HYDRAULIC SYMBOL

VALVE SPECIFICATIONS

4

1

2

3

Page 171: SOLENOID OPERATED DIRECTIONAL … 1000 38 69 7/8-14 DE-S2F SD18 2 WAY 2 POSITION NORMALLY CLOSED POPPET VALVES SLID PRATD DIRTIAL TRLS Page SD3 Via Malavolti, 36 • 41122 Modena •

SOLENOID OPERATED DIRECTIONAL CONTROLS

Page SD185

Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512 mail: [email protected] • www.tecnord.com

4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 mail: [email protected] • www.delta-power.com

WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken without independent study, evaluation, and testing for suitability.

W 2

0 /

2018

DIMENSIONS

OPTIONS BODIESBuna Standard 00 Blank Without BodyViton Standard V0 N 1/4 NPTF Ports

Buna, Push Only Override 0P S #6 SAE PortsViton, Push Only Override VP

VOLTAGE06 6 VDC12 12 VDC24 24 VDC36 36 VDC48 48 VDC25 25 VAC11 120 VAC22 220 VAC44 440 VAC

“D” COIL TERMINATION(All DC Except as Noted)

DL Double Lead SS Single SpadeDT Deutsch on Leads DT04-2P DS Double SpadeML Metri-Pack on Leads HC DIN 43650 (Hirschmann) - (AC&DC)PL Packard on Leads CL Conduit Lead - (AC Only)WL Weatherpack on Leads DI Deutsch - Integral DT04-2P

PQ-S4T – – – –

ORDERING INFORMATIONApproximate Coil Weight: .74 lbs (.33 kg)

12 VD

C

HY

DR

AU

LIC C

O.

DD

L12

4.88 [123.9]

2.11 [53.6]

5.93 [150.6]

.65 [16.5]

SEE COIL DATAFOR TERMINATIONS.

"PUSH ONLY" OVERRIDE

STANDARD

S1

S2

.56 [14.2]

HEX NUT

1.83 [46.6]

3/4-16 UNF2A THREAD

.88 [22.2] HEX

1.56 [39.6]

Page 172: SOLENOID OPERATED DIRECTIONAL … 1000 38 69 7/8-14 DE-S2F SD18 2 WAY 2 POSITION NORMALLY CLOSED POPPET VALVES SLID PRATD DIRTIAL TRLS Page SD3 Via Malavolti, 36 • 41122 Modena •

SOLENOID OPERATED DIRECTIONAL CONTROLS

Page SD190

Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512 mail: [email protected] • www.tecnord.com

4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 mail: [email protected] • www.delta-power.com

WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken without independent study, evaluation, and testing for suitability.

W 20 / 2018

DG-S4P DIRECT ACTING SPOOL, 4 WAY 3 POSITION, CLOSED CENTER

DESCRIPTION10 size, 7/8-14 thread, “Delta” series, solenoid operated, 4 way 3 position, closed center spool valve.

OPERATIONWhen de-energized the DG-S4P blocks flow at all ports. When outer coil (S1) is energized the valve allows flow from (2) to (1) and from (3) to (4). When inner coil (S2) is energized the valve allows flow from (2) to (3) and from (1) to (4).OPERATION OF MANUAL OVERRIDE OPTION: Bidirectional Override - Spring biased in neutral center position, when pushed the valve shifts in the (S2) direction, when pulled the valve shifts in the S1 direction.Push Only Override - Spring biased in neutral center position, when pushed the valve shifts in the (S2) direction.

FEATURES • Hardened parts for long life.• Efficient wet-armature construction.• Cartridges are voltage interchangeable.• Manual override option. • Industry common cavity.• Unitized, molded coil design.• Continuous duty rated solenoid.• Optional coil voltages and terminations.• Optional “I” Coil: Weatherproof, Thermal Shock, Immersion Safe.

Nominal Flow 8 GPM (30 LPM)Rated Operating Pressure 3000 PSI (207 bar)Typical Internal Leakage (150 SSU) 5 cu in/min (82 ml/min) per pathViscosity Range 36 to 3000 SSU (3 to 647 cSt)Filtration ISO 18/16/13Media Operating Temp. Range -40° to 250°F (-40° to 120°C)Weight .53 lbs (.24 kg)Operating Fluid Media General Purpose Hydraulic FluidCartridge Torque Requirements 30 ft-lbs (40.6 Nm)Coil Nut Torque Requirements 4-6 ft-lbs (5.4-8.1 Nm)Cavity DELTA 4WCavity Tools Kit (form tool, reamer, tap) 40500002Seal Kit 21191214

Flow (LPM)

0

25

50

75

100

125

150

0 2 4 6 8Flow (GPM)

0

5

10

0 5 10 2015 25 30

Pre

ssur

e D

rop

(PS

I)

Pre

ssur

e D

rop

(bar

)

Port 2 to 1 (eng S1) Port 3 to 4 (eng S1)

0

25

50

75

100

125

150

0 2 6 84Flow (GPM)

0

5

10

0 5 10 15 20 25 30

Pre

ssur

e D

rop

(PS

I)

Pre

ssur

e D

rop

(bar

)

Flow (LPM)

Port 1 to 4 (eng S2) Port 2 to 3 (eng S2)

Flow (LPM)

0

25

50

75

100

125

150

0 2 4 6 8Flow (GPM)

0

5

10

0 5 10 2015 25 30

Pre

ssur

e D

rop

(PS

I)

Pre

ssur

e D

rop

(bar

)

Port 2 to 1 (eng S1) Port 3 to 4 (eng S1)

0

25

50

75

100

125

150

0 2 6 84Flow (GPM)

0

5

10

0 5 10 15 20 25 30

Pre

ssur

e D

rop

(PS

I)

Pre

ssur

e D

rop

(bar

)

Flow (LPM)

Port 1 to 4 (eng S2) Port 2 to 3 (eng S2)

Actual Test Data (Cartridge Only)

PERFORMANCE HYDRAULIC SYMBOL

VALVE SPECIFICATIONS

Uses “L” Coil. Flow rating is at 1000 PSID maximum differential loading.

4

1

2

3

Page 173: SOLENOID OPERATED DIRECTIONAL … 1000 38 69 7/8-14 DE-S2F SD18 2 WAY 2 POSITION NORMALLY CLOSED POPPET VALVES SLID PRATD DIRTIAL TRLS Page SD3 Via Malavolti, 36 • 41122 Modena •

SOLENOID OPERATED DIRECTIONAL CONTROLS

Page SD191

Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512 mail: [email protected] • www.tecnord.com

4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 mail: [email protected] • www.delta-power.com

WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken without independent study, evaluation, and testing for suitability.

W 2

0 /

2018

DIMENSIONS

ORDERING INFORMATIONApproximate Coil Weight: .68 lbs (.31 kg)

OPTIONS BODIESBuna Standard 00 Blank Without BodyViton Standard V0 N 1/4 NPTF PortsBuna, Override 0M S #6 SAE PortsViton, Override VM

Buna, Push Only Override 0PViton, Push Only Override VP

VOLTAGE06 6 VDC12 12 VDC24 24 VDC36 36 VDC48 48 VDC25 24 VAC11 120 VAC22 220 VAC

“L” COIL TERMINATION 44 440 VAC(All DC Except as Noted)

IMMERSION PROOF “L” TYPEDL Double Lead SS Single Spade IA “I” Coil AMP Superseal - IntegralDT Deutsch on Leads DT04-2P DS Double Spade ID “I” Coil Deutsch - Integral DT04-2PML Metri-Pack on Leads HC DIN 43650 (Hirschmann) - (AC&DC) IJ “I” Coil AMP Jr. Timer - IntegralPL Packard on Leads CL Conduit Lead - (AC Only) IM “I” Coil Metri-Pack - IntegralWL Weatherpack on Leads DI Deutsch - Integral DT04-2P

DG-S4P – – – –

DE

LTA P

OW

ER

CO

.

PUSH ONLY OVERRIDE

STANDARD

1" HEX [25.4]

7/8-14 UNF-2A THREAD

5.82 [147.8]

4.85 [123.1]

2.44 [61.9]

.56 [14.3]

1.56 [39.6]

1.83 [46.6]

.75 [19.0]

HEX NUT

SEE COIL DATAFOR TREMINATIONS

Page 174: SOLENOID OPERATED DIRECTIONAL … 1000 38 69 7/8-14 DE-S2F SD18 2 WAY 2 POSITION NORMALLY CLOSED POPPET VALVES SLID PRATD DIRTIAL TRLS Page SD3 Via Malavolti, 36 • 41122 Modena •

SOLENOID OPERATED DIRECTIONAL CONTROLS

Page SD192

Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512 mail: [email protected] • www.tecnord.com

4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 mail: [email protected] • www.delta-power.com

WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken without independent study, evaluation, and testing for suitability.

W 20 / 2018

PQ-S4Q DIRECT ACTING SPOOL, 4 WAY 3 POSITION, CLOSED CENTER

DESCRIPTION8 size, 3/4-16 thread, “Power” series, solenoid operated, 4 way 3 position, closed center spool valve.

OPERATIONWhen de-energized the PQ-S4Q blocks flow to all ports. When outer coil (S1) is energized the valve allows flow from (2) to (1) and from (3) to (4). When inner coil (S2) is energized the valve allows flow from (2) to (3) and from (1) to (4).OPERATION OF MANUAL OVERRIDE OPTION: push Only Override - Spring biased in neutral center position, when pushed the valve shifts in the (S2) direction.

FEATURES • Hardened parts for long life.• Efficient wet-armature construction.• Cartridges are voltage interchangeable.• Industry common cavity.• Optional manual “push only” override.• Unitized, molded coil design.• Continuous duty rated solenoid.• Optional coil voltages and terminations.

Nominal Flow 6 GPM (23 LPM)Rated Operating Pressure 3000 PSI (207 bar)Typical Internal Leakage (150 SSU) 5 cu in/min (82 ml/min) per pathViscosity Range 36 to 3000 SSU (3 to 647 cSt)Filtration ISO 18/16/13Media Operating Temp. Range -40° to 250°F (-40° to 120°C)Weight .42 lbs (.19 kg)Operating Fluid Media General Purpose Hydraulic FluidCartridge Torque Requirements 30 ft-lbs (40.6 Nm)Coil Nut Torque Requirements 4-6 ft-lbs (5.4-8.1 Nm)Cavity POWER 4WCavity Tools Kit (form tool, reamer, tap) 40500029Seal Kit 21191108

0

50

100

150

200

420 6Flow (GPM)

0

5

10

0 5

Pre

ssur

e D

rop

(PS

I)

1510 20Flow (L PM)

Pre

ssur

e D

rop

(bar

)

Port 2 to 1 (eng S1) Port 3 to 4 (eng S1)

0

50

100

150

6420

200

Pre

ssur

e D

rop

(PS

I)

0

Flow (GPM)

5

10

0 5 10 15 20

Pre

ssur

e D

rop

(bar

)

Flow (LPM)

Port 1 to 4 (eng S2) Port 2 to 3 (eng S2)

0

50

100

150

200

420 6Flow (GPM)

0

5

10

0 5

Pre

ssur

e D

rop

(PS

I)

1510 20Flow (L PM)

Pre

ssur

e D

rop

(bar

)

Port 2 to 1 (eng S1) Port 3 to 4 (eng S1)

0

50

100

150

6420

200

Pre

ssur

e D

rop

(PS

I)

0

Flow (GPM)

5

10

0 5 10 15 20

Pre

ssur

e D

rop

(bar

)

Flow (LPM)

Port 1 to 4 (eng S2) Port 2 to 3 (eng S2)

Actual Test Data (Cartridge Only)

PERFORMANCE

Uses “P” Power coil. For higher flow see PQ-S4P. Flow rating based on maximum differential load of 1000 PSI. “OP” override is a push only non-detented button that actuates (S2) direction. For “I” coil environmental protection option, consult factory for special build configuration per Delta Standard 40295013.

HYDRAULIC SYMBOL

VALVE SPECIFICATIONS

4

1

2

3

Page 175: SOLENOID OPERATED DIRECTIONAL … 1000 38 69 7/8-14 DE-S2F SD18 2 WAY 2 POSITION NORMALLY CLOSED POPPET VALVES SLID PRATD DIRTIAL TRLS Page SD3 Via Malavolti, 36 • 41122 Modena •

SOLENOID OPERATED DIRECTIONAL CONTROLS

Page SD193

Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512 mail: [email protected] • www.tecnord.com

4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 mail: [email protected] • www.delta-power.com

WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken without independent study, evaluation, and testing for suitability.

W 2

0 /

2018

DIMENSIONS

ORDERING INFORMATIONApproximate Coil Weight: .42 lbs (.19 kg)

PQ-S4Q – – – –

DE

LTA P

OW

ER

CO

.

1.25 [31.7]

1.54 [39.1]

.56 [14.2]

HEX NUT

5.90 [149.9]

4.85 [123.1]

2.10 [53.3]

.65 [16.5] 3/4-16 UNF

2A THREAD

.88 [22.2] HEX

S1

S2

"PUSH ONLY" OVERRIDE

STANDARD

SEE COIL DATAFOR TERMINATIONS.

4.82 [122.3]

.59 [15.1]

1.72 [43.7]

2.75 [69.9]

.25 [6.4]

1.16 [29.4]

3.00 [76.2]

2.25 [57.2]

1.75 [44.5]

1.13 [28.6]

.25 [6.4]

1.25 [31.8]

.63 [15.9]

1.25 [31.7]

#6 SAE PORTS4X

.28 [7.1] DIA.MTG. HOLES2X

BODY WEIGHT: .67 lbs (.30 kg)

DE

LTA P

OW

ER

CO

.

OPTIONS BODIESBuna Standard 00 Blank Without BodyViton Standard V0 N 1/4 NPTF Ports

Buna, Push Only Override 0P S #6 SAE PortsViton, Push Only Override VP

VOLTAGE06 6 VDC12 12 VDC24 24 VDC36 36 VDC48 48 VDC25 24 VAC11 120 VAC22 220 VAC

“P” COIL TERMINATION 44 440 VAC(All DC Except as Noted)

IMMERSION PROOF “D” TYPEDL Double Lead SS Single Spade IA “I” Coil AMP Superseal - IntegralDT Deutsch on Leads DT04-2P DS Double Spade ID “I” Coil Deutsch - Integral DT04-2PML Metri-Pack on Leads HC DIN 43650 (Hirschmann) - (AC&DC) IJ “I” Coil AMP Jr. Timer - IntegralPL Packard on Leads CL Conduit Lead - (AC Only) IM “I” Coil Metri-Pack - IntegralWL Weatherpack on Leads DI Deutsch - Integral DT04-2P

Page 176: SOLENOID OPERATED DIRECTIONAL … 1000 38 69 7/8-14 DE-S2F SD18 2 WAY 2 POSITION NORMALLY CLOSED POPPET VALVES SLID PRATD DIRTIAL TRLS Page SD3 Via Malavolti, 36 • 41122 Modena •

SOLENOID OPERATED DIRECTIONAL CONTROLS

Page SD194

Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512 mail: [email protected] • www.tecnord.com

4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 mail: [email protected] • www.delta-power.com

WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken without independent study, evaluation, and testing for suitability.

W 20 / 2018

DG-S4S SPOOL OPERATED, 4 WAY 3 POSITION, SCOTCH CENTER

DESCRIPTION10 size, 7/8-14 thread, “Delta” series, solenoid operated, 4 way 3 position, scotch center spool valve.

OPERATIONWhen de-energized the DG-S4S blocks flow at (1) and (2) and allows flow from (3) to (4). When outer coil (S1) is energized the valve allows flow from (2) to (1) and from (3) to (4). When inner coil (S2) is nergized the valve allows flow from (2) to (3) and from (1) to (4).OPERATION OF MANUAL OVERRIDE OPTION: Bidirectional Override - Spring biased in neutral center position, when pushed the valve shifts in the (S2) direction, when pulled the valve shifts in the S1 direction.Push Only Override - Spring biased in neutral center position, when pushed the valve shifts in the (S2) direction.

FEATURES • Hardened parts for long life.• Efficient wet-armature construction.• Cartridges are voltage interchangeable.• Manual override option. • Industry common cavity.• Unitized, molded coil design.• Continuous duty rated solenoid.• Optional coil voltages and terminations.• Optional “I” Coil: Weatherproof, Thermal Shock, Immersion Safe.

Nominal Flow 6 GPM (23 LPM)Rated Operating Pressure 3000 PSI (207 bar)Typical Internal Leakage (150 SSU) 5 cu in/min (82 ml/min) per pathViscosity Range 36 to 3000 SSU (3 to 647 cSt)Filtration ISO 18/16/13Media Operating Temp. Range -40° to 250°F (-40° to 120°C)Weight .62 lbs (.28 kg)Operating Fluid Media General Purpose Hydraulic FluidCartridge Torque Requirements 30 ft-lbs (40.6 Nm)Coil Nut Torque Requirements 4-6 ft-lbs (5.4-8.1 Nm)Cavity DELTA 4WCavity Tools Kit (form tool, reamer, tap) 40500002Seal Kit 21191214

0

25

50

75

100

125

0

150

2 4 860

5

10

Flow (GP M)

0

Pres

sure

Dro

p (P

SI)

5 10 15 20 25 30Flow (LPM)

Pres

sure

Dro

p (b

ar)

Port 3 to 4 (de-eng) Port 3 to 4 (eng S1) Port 2 to 1 (eng S1)

0

25

50

75

100

125

0

150

2 4 6 8Flow (GPM)

0

5

10

0 5 10

Pre

ssur

e D

rop

(PS

I)

15 20 25 30Flow (L PM)

Pre

ssur

e D

rop

(bar

)

Port 1 to 4 (eng S2) Port 2 to 3 (eng S2)

0

25

50

75

100

125

0

150

2 4 860

5

10

Flow (GP M)

0

Pres

sure

Dro

p (P

SI)

5 10 15 20 25 30Flow (LPM)

Pres

sure

Dro

p (b

ar)

Port 3 to 4 (de-eng) Port 3 to 4 (eng S1) Port 2 to 1 (eng S1)

0

25

50

75

100

125

0

150

2 4 6 8Flow (GPM)

0

5

10

0 5 10

Pre

ssur

e D

rop

(PS

I)

15 20 25 30Flow (L PM)

Pre

ssur

e D

rop

(bar

)

Port 1 to 4 (eng S2) Port 2 to 3 (eng S2)

Actual Test Data (Cartridge Only)

PERFORMANCE HYDRAULIC SYMBOL

VALVE SPECIFICATIONS

Uses “L” Coil. Flow rating is at 1000 PSID maximum differentialloading.

4

1

2

3

Page 177: SOLENOID OPERATED DIRECTIONAL … 1000 38 69 7/8-14 DE-S2F SD18 2 WAY 2 POSITION NORMALLY CLOSED POPPET VALVES SLID PRATD DIRTIAL TRLS Page SD3 Via Malavolti, 36 • 41122 Modena •

SOLENOID OPERATED DIRECTIONAL CONTROLS

Page SD195

Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512 mail: [email protected] • www.tecnord.com

4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 mail: [email protected] • www.delta-power.com

WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken without independent study, evaluation, and testing for suitability.

W 2

0 /

2018

DIMENSIONS

ORDERING INFORMATIONApproximate Coil Weight: .68 lbs (.31 kg)

OPTIONS BODIESBuna Standard 00 Blank Without BodyViton Standard V0 N 1/4 NPTF PortsBuna, Override 0M S #6 SAE PortsViton, Override VM

Buna, Push Only Override 0PViton, Push Only Override VP

VOLTAGE06 6 VDC12 12 VDC24 24 VDC36 36 VDC48 48 VDC25 24 VAC11 120 VAC22 220 VAC

“L” COIL TERMINATION 44 440 VAC(All DC Except as Noted)

IMMERSION PROOF “L” TYPEDL Double Lead SS Single Spade IA “I” Coil AMP Superseal - IntegralDT Deutsch on Leads DT04-2P DS Double Spade ID “I” Coil Deutsch - Integral DT04-2PML Metri-Pack on Leads HC DIN 43650 (Hirschmann) - (AC&DC) IJ “I” Coil AMP Jr. Timer - IntegralPL Packard on Leads CL Conduit Lead - (AC Only) IM “I” Coil Metri-Pack - IntegralWL Weatherpack on Leads DI Deutsch - Integral DT04-2P

DG-S4S – – – –

DE

LTA P

OW

ER

CO

.

PUSH ONLY OVERRIDE

STANDARD

1" HEX [25.4]

7/8-14 UNF-2A THREAD

5.82 [147.8]

4.85 [123.1]

2.44 [61.9]

.56 [14.3]

1.56 [39.6]

1.83 [46.6]

.75 [19.0]

HEX NUT

SEE COIL DATAFOR TREMINATIONS

Page 178: SOLENOID OPERATED DIRECTIONAL … 1000 38 69 7/8-14 DE-S2F SD18 2 WAY 2 POSITION NORMALLY CLOSED POPPET VALVES SLID PRATD DIRTIAL TRLS Page SD3 Via Malavolti, 36 • 41122 Modena •

SOLENOID OPERATED DIRECTIONAL CONTROLS

Page SD196

W 20 / 2018

Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512 mail: [email protected] • www.tecnord.com

4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 mail: [email protected] • www.delta-power.com

WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken without independent study, evaluation, and testing for suitability.

Page 179: SOLENOID OPERATED DIRECTIONAL … 1000 38 69 7/8-14 DE-S2F SD18 2 WAY 2 POSITION NORMALLY CLOSED POPPET VALVES SLID PRATD DIRTIAL TRLS Page SD3 Via Malavolti, 36 • 41122 Modena •

SOLENOID OPERATED DIRECTIONAL CONTROLS

Page SD197

W 2

0 /

2018

Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512 mail: [email protected] • www.tecnord.com

4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 mail: [email protected] • www.delta-power.com

WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken without independent study, evaluation, and testing for suitability.

TRANSMISSION & BRAKE SPOOL VALVES

SOLENOID OPERATED DIRECTIONAL CONTROLS

SCREW-IN STYLE GPM PSI LPM BAR CAVITY MODEL PAGE

3 1000 11 70 5/8-18 TC-S3A SD200

3 1500 11 103 5/8-18 UC-S3T SD208

8 1500 30 103 7/8-14 DF-S3T SD210

6 1000 23 70 7/8-14 TF-S3D SD204

5 1000 19 70 7/8-14 TG-S4A SD214

SLIP-IN STYLE, FLANGED RETAINED GPM PSI LPM BAR CAVITY MODEL PAGE

6 1000 23 70 Special IE-S2H-56 SD198

6 1000 23 70 Special IF-S3A-57 SD202

6 1000 23 70 Special IF-S3D-57 SD206

1.5 700 6 50 Special IC-S3D-43 SD212

5 1000 19 70 Special IG-S4A-58 SD216

Page 180: SOLENOID OPERATED DIRECTIONAL … 1000 38 69 7/8-14 DE-S2F SD18 2 WAY 2 POSITION NORMALLY CLOSED POPPET VALVES SLID PRATD DIRTIAL TRLS Page SD3 Via Malavolti, 36 • 41122 Modena •

SOLENOID OPERATED DIRECTIONAL CONTROLS

Page SD200

Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512 mail: [email protected] • www.tecnord.com

4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 mail: [email protected] • www.delta-power.com

WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken without independent study, evaluation, and testing for suitability.

W 20 / 2018

TC-S3A DIRECT ACTING SPOOL, 3 WAY 2 POSITION, TRANSMISSION & BRAKE

DESCRIPTION7 size, 5/8-18 thread, “Mini” series, solenoid operated, 3 way 2 position, transmission & brake spool valve.

OPERATIONWhen de-energized the TC-S3A blocks flow at (1) and allows flow from (3) to (2). When energized the valve allows flow from (1) to (3) and blocks flow at (2).

FEATURES • Hardened parts for long life.• Efficient wet-armature construction.• Cartridges are voltage interchangeable.• Industry common cavity.• Unitized, molded coil design.• Continuous duty rated solenoid.• Optional coil voltages and terminations.

0

50

100

150

2 4310

200

Flow (GPM)

0

5

10

0 5 10

Pre

ssur

e D

rop

(PS

I)

15Flow (LPM)

Pre

ssur

e D

rop

(bar

)

Port 1 to 3 (eng) Port 3 to 2 (de-eng)

Nominal Flow 3 GPM (11 LPM) from (1) to (3) 2 GPM (7.6 LPM) from (3) to (2)Rated Operating Pressure 1000 PSI (70 bar)Typical Internal Leakage (150 SSU) 5 cu in/min (82 ml/min) Viscosity Range 36 to 3000 SSU (3 to 647 cSt)Filtration ISO 20/18/15Media Operating Temp. Range -40° to 250°F (-40° to 120°C)Weight .14 lbs (.06 kg)Operating Fluid Media General Purpose Hydraulic FluidCartridge Torque Requirements 15 ft-lbs (20.3 Nm)Coil Nut Torque Requirements 3-4 ft-lbs (4.1-5.4 Nm)Cavity MINI 3WCavity form Tool (finishing) 40500004Seal Kit 21191006

0

50

100

150

2 4310

200

Flow (GPM)

0

5

10

0 5 10

Pre

ssur

e D

rop

(PS

I)

15Flow (LPM)

Pre

ssur

e D

rop

(bar

)

Port 1 to 3 (eng) Port 3 to 2 (de-eng)

Actual Test Data (Cartridge Only)

VALVE SPECIFICATIONS

Contamination Tolerant Product. This valve is designed for transmission and brake applications.Consult factory for alternate low wattage coil options.

PERFORMANCE

HYDRAULIC SYMBOL

Page 181: SOLENOID OPERATED DIRECTIONAL … 1000 38 69 7/8-14 DE-S2F SD18 2 WAY 2 POSITION NORMALLY CLOSED POPPET VALVES SLID PRATD DIRTIAL TRLS Page SD3 Via Malavolti, 36 • 41122 Modena •

SOLENOID OPERATED DIRECTIONAL CONTROLS

Page SD201

Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512 mail: [email protected] • www.tecnord.com

4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 mail: [email protected] • www.delta-power.com

WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken without independent study, evaluation, and testing for suitability.

W 2

0 /

2018

OPTIONS BODIESBuna Standard 00 Blank Without BodyViton Standard V0 N 1/4” BSP Ports

S #6 SAE Ports

VOLTAGE (other voltages available on request)12 12 VDC24 24 VDC22 220 VAC without internal rectifier

Note: use screen only if flow direction is from (1) to (2)

“K” COIL TERMINATION(All DC Except as Noted)

IMMERSION PROOF “P” TYPEDL Double Lead HC DIN 43650 (Hirschmann) - (AC&DC) PIA “I” Coil AMP Superseal - Integral

(several types of termination can be DI Deutsch - Integral DT04-2P PID “I” Coil Deutsch - Integral DT04-2Pattached on leads on request) PIJ “I” Coil AMP Jr. Timer - Integral

PIM “I” Coil Metri-Pack - Integral

TC-S3A – – – –

DIMENSIONS

ORDERING INFORMATIONApproximate Coil Weight: .42 lbs (.19 kg)

Page 182: SOLENOID OPERATED DIRECTIONAL … 1000 38 69 7/8-14 DE-S2F SD18 2 WAY 2 POSITION NORMALLY CLOSED POPPET VALVES SLID PRATD DIRTIAL TRLS Page SD3 Via Malavolti, 36 • 41122 Modena •

SOLENOID OPERATED DIRECTIONAL CONTROLS

Page SD202

Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512 mail: [email protected] • www.tecnord.com

4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 mail: [email protected] • www.delta-power.com

WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken without independent study, evaluation, and testing for suitability.

W 20 / 2018

IF-S3A-57-MP12 3 WAY 2 POSITION N.O. TRANSMISSION & BRAKE APPLICATION SPOOL VALVE

DESCRIPTIONSpecial series, solenoid operated, 3 way normally open, transmission and brake spool type flanged retained hydraulic valve.

OPERATIONWhen de-energized the IF-S3A-57-MP12 allows flow from (2) to (3) and (3) to (2), and blocks flow at (1).When energized the valve allows flow from (1) to (3) and blocks flow at port (2).

FEATURES • Efficient wet-armature construction.• Cartridges are voltage interchangeable.• Unitized valve/coil.• Continuous duty rated solenoid.• Optional coil voltages and terminations.

Actual Test Data (Cartridge Only)

HYDRAULIC SYMBOL

PERFORMANCE

Nominal Flow 6 GPM (23 LPM)Max Operating Pressure 1000 PSI (70 bar)Typical Internal Leakage 50 ml/min Viscosity Range 36 to 3000 SSU (3 to 647 cSt)Filtration ISO 18/16/13Media Operating Temp. Range -35° to 200°F (-37.2° to 93.3°C)Weight .75 lbs (.34 kg)Operating Fluid Media General Purpose Hydraulic FluidCavity SpecialCavity Form Tool (Finishing) T057Seal Kit Special

VALVE SPECIFICATIONS

Nominal Operating Voltage 12 VDC ±5%Pull-in Voltage 8.5 VDC at 212°F (100°C)Peak Voltage 25 VDC for 5 min at 50°F (10°C) Temperature Range -40°F to 230°F (-40°C) to (110°C)Coil Resistance 7.3 Ohm ±5% at 68°F (20°C)Coil Termination AMP Superseal - IntegralConnector Color Black

COIL SPECIFICATIONS

Consult Factory for Valve retention options.Flanged Retained Product.

1

2

3

Page 183: SOLENOID OPERATED DIRECTIONAL … 1000 38 69 7/8-14 DE-S2F SD18 2 WAY 2 POSITION NORMALLY CLOSED POPPET VALVES SLID PRATD DIRTIAL TRLS Page SD3 Via Malavolti, 36 • 41122 Modena •

SOLENOID OPERATED DIRECTIONAL CONTROLS

Page SD203

Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512 mail: [email protected] • www.tecnord.com

4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 mail: [email protected] • www.delta-power.com

WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken without independent study, evaluation, and testing for suitability.

W 2

0 /

2018

1.49 [37.8]

2.66 [67.5]

1.81 [46.0]

4.47 [113.5]

.12 [3.0]

.79 [20.0]

1.38 [35.0]

DIMENSIONS FOR REFERENCE ONLY

2.06 [52.3]

1.45 [36.9]

.83 [21.0]

.11 [2.8]

.63 [15.9]

.69 [17.5]

.94 [23.8]

1.50 [38.0]

.22 [5.7]

.94 [23.8]

1.61 [40.9]

1.98 [50.4]

2.18 [55.3]

FOR SPECIFIC CAVITY INFORMATION CONSULT FACTORY

IF-S3A-57-MP12

DIMENSIONS

ORDERING INFORMATION

Page 184: SOLENOID OPERATED DIRECTIONAL … 1000 38 69 7/8-14 DE-S2F SD18 2 WAY 2 POSITION NORMALLY CLOSED POPPET VALVES SLID PRATD DIRTIAL TRLS Page SD3 Via Malavolti, 36 • 41122 Modena •

SOLENOID OPERATED DIRECTIONAL CONTROLS

Page SD204

Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512 mail: [email protected] • www.tecnord.com

4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 mail: [email protected] • www.delta-power.com

WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken without independent study, evaluation, and testing for suitability.

W 20 / 2018

TF-S3D DIRECT ACTING SPOOL, 3 WAY 2 POSITION, TRANSMISSION & BRAKE

DESCRIPTION10 size, 7/8-14 thread, “Delta” series, solenoid operated, 3 way 2 position, transmission & brake, spool valve.

OPERATIONWhen de-energized the TF-S3D allows flow from (3) to (1) and blocks flow at port (2). When energized the valve allows flow from (3) to (2) and blocks flow at port (1).

FEATURES • Hardened parts for long life.• Efficient wet-armature construction.• Cartridges are voltage interchangeable.• Industry common cavity.• Unitized, molded coil design.• Continuous duty rated solenoid.• Optional coil voltages and terminations.• Optional “I” Coil: Weatherproof, Thermal Shock, Immersion Safe.

Nominal Flow 6 GPM (23 LPM)Rated Operating Pressure 1000 PSI (70 bar)Typical Internal Leakage (150 SSU) 3 cu in/min (50 ml/min) Viscosity Range 36 to 3000 SSU (3 to 647 cSt)Filtration ISO 18/16/13Media Operating Temp. Range -40° to 250°F (-40° to 120°C)Weight .28 lbs (.12 kg)Operating Fluid Media General Purpose Hydraulic FluidCartridge Torque Requirements 30 ft-lbs (40.6 Nm)Coil Nut Torque Requirements 3-4 ft-lbs (4.1-5.4 Nm)Cavity DELTA 3WCavity Tools Kit (form tool, reamer, tap) 40500001Seal Kit 21191210

Actual Test Data (Cartridge Only)

VALVE SPECIFICATIONSPERFORMANCE

HYDRAULIC SYMBOL

Page 185: SOLENOID OPERATED DIRECTIONAL … 1000 38 69 7/8-14 DE-S2F SD18 2 WAY 2 POSITION NORMALLY CLOSED POPPET VALVES SLID PRATD DIRTIAL TRLS Page SD3 Via Malavolti, 36 • 41122 Modena •

SOLENOID OPERATED DIRECTIONAL CONTROLS

Page SD205

Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512 mail: [email protected] • www.tecnord.com

4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 mail: [email protected] • www.delta-power.com

WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken without independent study, evaluation, and testing for suitability.

W 2

0 /

2018

OPTIONS BODIESBuna Standard 00 Blank Without BodyViton Standard V0 N 3/8” BSP PortsBuna, Screen A0 S #8 SAE PortsViton, Screen W0

VOLTAGE (other voltages available on request)12 12 VDC

Note: use screen only if flow 24 24 VDCdirection is from (1) to (2) 22 220 VAC without internal rectifier

“V” COIL TERMINATION(All DC Except as Noted)

IMMERSION PROOF “D” TYPEDL Double Lead HC DIN 43650 (Hirschmann) - (AC&DC) DIA “I” Coil AMP Superseal - Integral

(several types of termination can be DI Deutsch - Integral DT04-2P DID “I” Coil Deutsch - Integral DT04-2Pattached on leads on request) DIJ “I” Coil AMP Jr. Timer - Integral

DIM “I” Coil Metri-Pack - Integral

TF-S3D – – – –

DIMENSIONS

ORDERING INFORMATIONApproximate Coil Weight: .56 lbs (.25 kg)

Page 186: SOLENOID OPERATED DIRECTIONAL … 1000 38 69 7/8-14 DE-S2F SD18 2 WAY 2 POSITION NORMALLY CLOSED POPPET VALVES SLID PRATD DIRTIAL TRLS Page SD3 Via Malavolti, 36 • 41122 Modena •

SOLENOID OPERATED DIRECTIONAL CONTROLS

Page SD206

Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512 mail: [email protected] • www.tecnord.com

4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 mail: [email protected] • www.delta-power.com

WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken without independent study, evaluation, and testing for suitability.

W 20 / 2018

IF-S3D-57-MP12 3 WAY 2 POSITION, N.O. TRANSMISSION & BRAKE APPLICATION SPOOL VALVE

DESCRIPTIONSpecial series, solenoid operated, 3 way 2 position, transmission and brake spool type flanged retained hydraulic valve.

OPERATIONWhen de-energized the IF-S3D-57-MP12 allows flow from (1) to (3) and (3) to (1), and blocks flow at (2).When energized the valve allows flow from (3) to (2) and (2) to (3) blocks flow at port (1).

FEATURES • Efficient wet-armature construction.• Cartridges are voltage interchangeable.• Unitized valve/coil.• Continuous duty rated solenoid.• Optional coil voltages and terminations.

Actual Test Data (Cartridge Only)

Consult Factory for Valve retention options.Flanged Retained Product.

HYDRAULIC SYMBOL

PERFORMANCE

1

2

3

Nominal Flow 6 GPM (23 LPM)Max Operating Pressure 1000 PSI (70 bar)Typical Internal Leakage 50 ml/min Viscosity Range 36 to 3000 SSU (3 to 647 cSt)Filtration ISO 18/16/13Media Operating Temp. Range -35° to 200°F (-37.2° to 93.3°C)Weight .75 lbs (.34 kg)Operating Fluid Media General Purpose Hydraulic FluidCavity SpecialCavity Form Tool (Finishing) T057Seal Kit Special

VALVE SPECIFICATIONS

Nominal Operating Voltage 12 VDC ±5%Pull-in Voltage 8.5 VDC at 212°F (100°C)Peak Voltage 25 VDC for 5 min at 50°F (10°C) Temperature Range -40°F to 230°F (-40°C) to (110°C)Coil Resistance 7.3 Ohm ±5% at 68°F (20°C)Coil Termination AMP Superseal - IntegralConnector Color Black

COIL SPECIFICATIONS

Page 187: SOLENOID OPERATED DIRECTIONAL … 1000 38 69 7/8-14 DE-S2F SD18 2 WAY 2 POSITION NORMALLY CLOSED POPPET VALVES SLID PRATD DIRTIAL TRLS Page SD3 Via Malavolti, 36 • 41122 Modena •

SOLENOID OPERATED DIRECTIONAL CONTROLS

Page SD207

Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512 mail: [email protected] • www.tecnord.com

4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 mail: [email protected] • www.delta-power.com

WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken without independent study, evaluation, and testing for suitability.

W 2

0 /

2018

IF-S3D-57-MP12

DIMENSIONS

ORDERING INFORMATION

1.49 [37.8]

2.66 [67.5]

1.81 [46.0]

4.47 [113.5]

.12 [3.0]

.79 [20.0]

1.38 [35.0]

DIMENSIONS FOR REFERENCE ONLY

2.06 [52.3]

1.45 [36.9]

.83 [21.0]

.11 [2.8]

.63 [15.9]

.69 [17.5]

.94 [23.8]

1.50 [38.0]

.22 [5.7]

.94 [23.8]

1.61 [40.9]

1.98 [50.4]

2.18 [55.3]

FOR SPECIFIC CAVITY INFORMATION CONSULT FACTORY

Page 188: SOLENOID OPERATED DIRECTIONAL … 1000 38 69 7/8-14 DE-S2F SD18 2 WAY 2 POSITION NORMALLY CLOSED POPPET VALVES SLID PRATD DIRTIAL TRLS Page SD3 Via Malavolti, 36 • 41122 Modena •

SOLENOID OPERATED DIRECTIONAL CONTROLS

Page SD208

Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512 mail: [email protected] • www.tecnord.com

4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 mail: [email protected] • www.delta-power.com

WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken without independent study, evaluation, and testing for suitability.

W 20 / 2018

UC-S3T DIRECT ACTING SPOOL, 3 WAY 2 POSITION, TRANSMISSION & BRAKE

DESCRIPTION7 size, 5/8-18 thread, “Mini” series, solenoid operated, 3 way 2 position, transmission & brake spool valve.

OPERATIONWhen de-energized the UC-S3T blocks flow at (1) and allows flow from (3) to (2). When energized, thevalve allows flow from (1) to (3) and blocks flow at (2).

FEATURES • Hardened parts for long life.• Efficient wet-armature construction.• Cartridges are voltage interchangeable.• Industry common cavity.• Unitized, molded coil design.• Continuous duty rated solenoid.• Optional coil voltages and terminations.

Nominal Flow 3 GPM (11 LPM) from (1) to (3) 2 GPM (8 LPM) from (3) to (2)Rated Operating Pressure 1500 PSI (103 bar)Typical Internal Leakage (150 SSU) 8 cu in/min (131 ml/min)Viscosity Range 36 to 3000 SSU (3 to 647 cSt)Filtration ISO 18/16/13Media Operating Temp. Range -40° to 250°F (-40° to 120°C)Weight .14 lbs (.06 kg)Operating Fluid Media General Purpose Hydraulic FluidCartridge Torque Requirements 15 ft-lbs (20.3 Nm)Coil Nut Torque Requirements 4-6 ft-lbs (5.4-8.1 Nm)Cavity MINI 3WCavity Form Tool (Finishing) 40500004Seal Kit 21191006

Actual Test Data (Cartridge Only)

VALVE SPECIFICATIONS

0

50

100

150

0

200

1 2 3 4Flow (GPM)

0

5

10

0 5 10 15

Pres

sure

Dro

p (P

SI)

Flow (LPM)

Pres

sure

Dro

p (B

AR)

Port 1 to 3 (eng) Port 3 to 2 (de-eng)

0

50

100

150

0

200

1 2 3 4Flow (GPM)

0

5

10

0 5 10 15

Pres

sure

Dro

p (P

SI)

Flow (LPM)

Pres

sure

Dro

p (B

AR)

Port 1 to 3 (eng) Port 3 to 2 (de-eng)

PERFORMANCE

HYDRAULIC SYMBOL

1

2

3

Page 189: SOLENOID OPERATED DIRECTIONAL … 1000 38 69 7/8-14 DE-S2F SD18 2 WAY 2 POSITION NORMALLY CLOSED POPPET VALVES SLID PRATD DIRTIAL TRLS Page SD3 Via Malavolti, 36 • 41122 Modena •

SOLENOID OPERATED DIRECTIONAL CONTROLS

Page SD209

Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512 mail: [email protected] • www.tecnord.com

4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 mail: [email protected] • www.delta-power.com

WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken without independent study, evaluation, and testing for suitability.

W 2

0 /

2018

DIMENSIONS

ORDERING INFORMATIONApproximate Coil Weight: .30 lbs (.14 kg)

OPTIONS BODIESBuna Standard 00 Blank Without BodyViton Standard V0 N 1/4 NPTF Ports

S #6 SAE Ports

VOLTAGE06 6 VDC12 12 VDC24 24 VDC36 36 VDC48 48 VDC25 24 VAC11 120 VAC22 220 VAC

“P” COIL TERMINATION 44 440 VAC(All DC Except as Noted)

IMMERSION PROOF “P” TYPEDL Double Lead SS Single Spade IA “I” Coil AMP Superseal - IntegralDT Deutsch on Leads DT04-2P DS Double Spade ID “I” Coil Deutsch - Integral DT04-2PML Metri-Pack on Leads HC DIN 43650 (Hirschmann) - (AC&DC) IJ “I” Coil AMP Jr. Timer - IntegralPL Packard on Leads CL Conduit Lead - (AC Only) IM “I” Coil Metri-Pack - IntegralWL Weatherpack on Leads DI Deutsch - Integral DT04-2P

UC-S3T – – – –

Note: Aluminum, NOT durability rated for 4000 PSI. Consult factory for body options.

Page 190: SOLENOID OPERATED DIRECTIONAL … 1000 38 69 7/8-14 DE-S2F SD18 2 WAY 2 POSITION NORMALLY CLOSED POPPET VALVES SLID PRATD DIRTIAL TRLS Page SD3 Via Malavolti, 36 • 41122 Modena •

SOLENOID OPERATED DIRECTIONAL CONTROLS

Page SD210

Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512 mail: [email protected] • www.tecnord.com

4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 mail: [email protected] • www.delta-power.com

WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken without independent study, evaluation, and testing for suitability.

W 20 / 2018

DF-S3T DIRECT ACTING SPOOL, 3 WAY 2 POSITION, TRANSMISSION & BRAKE

DESCRIPTION10 size, 7/8-14 thread, “Delta” series, solenoid operated, 3 way 2 position, transmission & brake spool valve.

OPERATIONWhen de-energized the DF-S3T allows flow from (3) to (2) and blocks flow at port (1). When energized the valve allows flow from (1) to (3) and blocks flow at port (2).OPERATION OF MANUAL OVERRIDE OPTION: to override, pull knob out. On the detented version, after pulling knob out twist 180 degrees and release. The valve will remain in that position.

FEATURES • Hardened parts for long life.• Efficient wet-armature construction.• Cartridges are voltage interchangeable.• Manual override option.• Industry common cavity.• Unitized, molded coil design.• Continuous duty rated solenoid.• Optional coil voltages and terminations.• Optional “I” Coil: Weatherproof, Thermal Shock, Immersion Safe.

Nominal Flow 8 GPM (30 LPM)Rated Operating Pressure 1500 PSI (103 bar)Typical Internal Leakage (150 SSU) 5 cu in/min (82 ml/min)Viscosity Range 36 to 3000 SSU (3 to 647 cSt)Filtration ISO 18/16/13Media Operating Temp. Range -40° to 250°F (-40° to 120°C)Weight .28 lbs (.12 kg)Operating Fluid Media General Purpose Hydraulic FluidCartridge Torque Requirements 30 ft-lbs (40.6 Nm)Coil Nut Torque Requirements 4-6 ft-lbs (5.4-8.1 Nm)Cavity DELTA 3WCavity Tools Kit (form tool, reamer, tap) 40500001Seal Kit 21191204

VALVE SPECIFICATIONS

Actual Test Data (Cartridge Only)

0

50

100

0

150

2 4 6 80

Pre

ssur

e D

rop

(PS

I)

5

10

0

Flow (GPM)

5 10 15 20 25 30

Pre

ssur

e D

rop

(bar

)

Flow (LPM)

Port 1 to 3 (eng) Port 3 to 2 (de-eng)

PERFORMANCE

HYDRAULIC SYMBOLContamination Tolerant Product. This valve is designed for transmission and brake applications. Consult factory for alternate low wattage coil options.

1

2

3

Page 191: SOLENOID OPERATED DIRECTIONAL … 1000 38 69 7/8-14 DE-S2F SD18 2 WAY 2 POSITION NORMALLY CLOSED POPPET VALVES SLID PRATD DIRTIAL TRLS Page SD3 Via Malavolti, 36 • 41122 Modena •

SOLENOID OPERATED DIRECTIONAL CONTROLS

Page SD211

Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512 mail: [email protected] • www.tecnord.com

4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 mail: [email protected] • www.delta-power.com

WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken without independent study, evaluation, and testing for suitability.

W 2

0 /

2018

DIMENSIONS

ORDERING INFORMATION

OPTIONS BODIESBuna Standard 00 Blank Without BodyViton Standard V0 N 1/4 NPTF PortsBuna, Override 0M S #6 SAE PortsViton, Override VM

Buna, Override, Non-detent B1Viton, Override, Non-detent V1 VOLTAGE

Buna, Screen A0 06 6 VDCViton, Screen W0 12 12 VDC

Buna, Screen, Override, Non-detent B3 24 24 VDCViton, Screen, Override, Non-detent V3 36 36 VDC

Buna, Screen, Override, Detent B4 48 48 VDCViton, Screen, Override, Detent V4 25 24 VAC

11 120 VACNote: use screen only if flow 22 220 VAC

direction is from (1) to (2) 44 440 VAC

“D” COIL TERMINATION(All DC Except as Noted)

IMMERSION PROOF “D” TYPEDL Double Lead SS Single Spade IA “I” Coil AMP Superseal - IntegralDT Deutsch on Leads DT04-2P DS Double Spade ID “I” Coil - Deutsch - Integral DT04-2PML Metri-Pack on Leads HC DIN 43650 (Hirschmann) - (AC&DC) IJ “I” Coil AMP Jr. Timer - IntegralPL Packard on Leads CL Conduit Lead - (AC Only) IM “I” Coil - Metri-Pack - IntegralWL Weatherpack on Leads DI Deutsch - Integral DT04-2P

DF-S3T – – – – Approximate Coil Weight: .74 lbs (.33 kg)

DE

LTA P

OW

ER

CO

2.35 [59.6]

3.35 [85.1]

1.81 [46.0]

.22 [5.6]

7/8-14 UNF2A THREAD

1.00 [25.4] HEX

1.56 [39.6]

1.83 [46.6]

.75 [19.1]

HEX NUT

SEE COIL DATAFOR TERMINATIONS

STANDARD

MANUAL OVERRIDE

7/16-20 UNF2A THREAD

DE

LTA P

OW

ER

CO

.

2.28 [58.0]

2.50 [63.5]

1.37 [34.8]

.63 [15.9]

2.12 [53.8]

2.50 [63.5]

2.25 [57.2]

1.25 [31.8]

.13 [3.2]

1.56 [39.6]

1.50 [38.1]

.75 [19.1]

.28 [7.14] DIA.MTG. HOLES2X

#6 SAE PORTS3X

BODY WEIGHT: .76 lbs (.35 kg)

Page 192: SOLENOID OPERATED DIRECTIONAL … 1000 38 69 7/8-14 DE-S2F SD18 2 WAY 2 POSITION NORMALLY CLOSED POPPET VALVES SLID PRATD DIRTIAL TRLS Page SD3 Via Malavolti, 36 • 41122 Modena •

SOLENOID OPERATED DIRECTIONAL CONTROLS

Page SD212

Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512 mail: [email protected] • www.tecnord.com

4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 mail: [email protected] • www.delta-power.com

WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken without independent study, evaluation, and testing for suitability.

W 20 / 2018

IC-S3D-43 DIRECT ACTING SPOOL, 3 WAY 2 POSITION, SELECTOR

DESCRIPTIONSpecial cavity, solenoid operated, 3 way 2 position spool type, flanged retained hydraulic valve.

OPERATIONWhen de-energized the IC-S3D-43 allows flow from (1) to (3) and (3) to (1), and blocks flow at (2).When energized the valve allows flow from (3) to (2) and (2) to (3) blocks flow at port (1).

FEATURES • Hardened parts for long life.• Slip-in style.• Efficient wet-armature construction.• Integral waterproof coil.• Continuos duty rated solenoid.• Optional coil voltages and terminations.

Actual Test Data (Cartridge Only)

PERFORMANCE

HYDRAULIC SYMBOL

Nominal Flow 1.5 GPM (6 LPM) @ 8 bar Delta PMax Inlet Pressure 700 PSI (50 bar)Max Back-Pressure at T Port 20 barInternal Leakage 15 ml/min @ 500 PSI (35 bar) inletViscosity Range 36 to 3000 SSU (3 to 647 cSt)Filtration ISO 18/16/13Media Operating Temp. Range -30°C / +100°CWeight .54 lbs (.25 kg)Operating Fluid Media General Purpose Hydraulic FluidCavity T043Cavity Tool Kit K-T043Flange Mounting Screws and Torque M4x10 / 3ft-lbs (4 Nm)

VALVE SPECIFICATIONS

Coil Resistance (12 VDC) 7 Ohm ±5% at 68°F (20°C)Coil Resistance (24 VDC) 25 Ohm ±5% at 68°F (20°C)Protection Degree IP 67 according to IEC 529Coil Termination Deutsch-Integral DT04-2P AMP Jr. Timer 84-9419Color Connectors Black

COIL SPECIFICATIONS

Flanged Retained Product. Coil is an integral part of the valve and is not serviceable.

Page 193: SOLENOID OPERATED DIRECTIONAL … 1000 38 69 7/8-14 DE-S2F SD18 2 WAY 2 POSITION NORMALLY CLOSED POPPET VALVES SLID PRATD DIRTIAL TRLS Page SD3 Via Malavolti, 36 • 41122 Modena •

SOLENOID OPERATED DIRECTIONAL CONTROLS

Page SD213

Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512 mail: [email protected] • www.tecnord.com

4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 mail: [email protected] • www.delta-power.com

WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken without independent study, evaluation, and testing for suitability.

W 2

0 /

2018

DIMENSIONSDIMENSIONS

ORDERING INFORMATIONApproximate Coil Weight: .42 lbs (.19 kg)

IC-S3D-43 – –

COILTERMINATION

VOLTAGE OPTIONS BODIES

AJ - AMP Jr. Timer 12 VDC 00 - NBR seals Blank - Without body

DT - Deutsch DT04

24 VDC N - 1/4” BSP Ports

DH - Deutsch DT04 Horizontal

S - #6 SAE Ports

Page 194: SOLENOID OPERATED DIRECTIONAL … 1000 38 69 7/8-14 DE-S2F SD18 2 WAY 2 POSITION NORMALLY CLOSED POPPET VALVES SLID PRATD DIRTIAL TRLS Page SD3 Via Malavolti, 36 • 41122 Modena •

SOLENOID OPERATED DIRECTIONAL CONTROLS

Page SD214

Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512 mail: [email protected] • www.tecnord.com

4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 mail: [email protected] • www.delta-power.com

WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken without independent study, evaluation, and testing for suitability.

W 20 / 2018

TG-S4A DIRECT ACTING SPOOL, 4 WAY 2 POSITION, TRANSMISSION & BRAKE

DESCRIPTION10 size, 7/8-14 thread, “Delta” series, solenoid operated, 4 way 2 position, transmission & brake, spool valve.

OPERATIONWhen de-energized the TG-S4A allows flow between (1) to (4) and (2) to (3). When energized the valve allows flow between (2) to (1) and (3) to (4).

FEATURES • Hardened parts for long life.• Efficient wet-armature construction.• Cartridges are voltage interchangeable.• Industry common cavity.• Unitized, molded coil design.• Continuous duty rated solenoid.• Optional coil voltages and terminations.• Optional “I” Coil: Weatherproof, Thermal Shock, Immersion Safe.

Nominal Flow 5 GPM (19 LPM)Rated Operating Pressure 1000 PSI (70 bar)Typical Internal Leakage (150 SSU) 1.2 cu in/min (20 ml/min) per pathViscosity Range 36 to 3000 SSU (3 to 647 cSt)Filtration ISO 18/16/13Media Operating Temp. Range -40° to 250°F (-40° to 120°C)Weight .32 lbs (.15 kg)Operating Fluid Media General Purpose Hydraulic FluidCartridge Torque Requirements 30 ft-lbs (40.6 Nm)Coil Nut Torque Requirements 3-4 ft-lbs (4.1-5.4 Nm)Cavity DELTA 4WCavity Tools Kit (form tool, reamer, tap) 40500002Seal Kit 21191214

Actual Test Data (Cartridge Only)

VALVE SPECIFICATIONSPERFORMANCE

HYDRAULIC SYMBOL

Page 195: SOLENOID OPERATED DIRECTIONAL … 1000 38 69 7/8-14 DE-S2F SD18 2 WAY 2 POSITION NORMALLY CLOSED POPPET VALVES SLID PRATD DIRTIAL TRLS Page SD3 Via Malavolti, 36 • 41122 Modena •

SOLENOID OPERATED DIRECTIONAL CONTROLS

Page SD215

Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512 mail: [email protected] • www.tecnord.com

4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 mail: [email protected] • www.delta-power.com

WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken without independent study, evaluation, and testing for suitability.

W 2

0 /

2018

OPTIONS BODIESBuna Standard 00 Blank Without BodyViton Standard V0 N 3/8” BSP Ports

S #8 SAE Ports

VOLTAGE (other voltages available on request)12 12 VDC24 24 VDC22 220 VAC without internal rectifier

“V” COIL TERMINATION(All DC Except as Noted)

IMMERSION PROOF “D” TYPEDL Double Lead HC DIN 43650 (Hirschmann) - (AC&DC) DIA “I” Coil AMP Superseal - Integral

(several types of termination can be DI Deutsch - Integral DT04-2P DID “I” Coil Deutsch - Integral DT04-2Pattached on leads on request) DIJ “I” Coil AMP Jr. Timer - Integral

DIM “I” Coil Metri-Pack - Integral

TG-S4A – – – –

DIMENSIONS

ORDERING INFORMATIONApproximate Coil Weight: .74 lbs (.33 kg)

Page 196: SOLENOID OPERATED DIRECTIONAL … 1000 38 69 7/8-14 DE-S2F SD18 2 WAY 2 POSITION NORMALLY CLOSED POPPET VALVES SLID PRATD DIRTIAL TRLS Page SD3 Via Malavolti, 36 • 41122 Modena •

SOLENOID OPERATED DIRECTIONAL CONTROLS

Page SD216

Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512 mail: [email protected] • www.tecnord.com

4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 mail: [email protected] • www.delta-power.com

WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken without independent study, evaluation, and testing for suitability.

W 20 / 2018

IG-S4A-58-MP12-A 4 WAY 2 POSITION, SLIP-IN TRANSMISSION SPOOL VALVE

DESCRIPTIONSpecial series, solenoid operated, 4 way 2 position, transmission spool type, flanged retained hydraulic valve.

OPERATIONWhen de-energized the IG-S4A-58-MP12-A allows flow from (2) to (3) and from (1) to (4).When energized the valve allows flow from (2) to (1) and from (3) to (4).

FEATURES • Efficient wet-armature construction.• Cartridges are voltage interchangeable.• Unitized valve/coil.• Continuous duty rated solenoid.• Optional coil voltages and terminations.

Actual Test Data (Cartridge Only)

Consult Factory for Valve retention options.Flanged Retained Product.

HYDRAULIC SYMBOL

PERFORMANCE

Nominal Flow 5 GPM (19 LPM)Max Operating Pressure 1000 PSI (70 bar)Typical Internal Leakage 50 ml/min Viscosity Range 36 to 3000 SSU (3 to 647 cSt)Filtration ISO 18/16/13Media Operating Temp. Range -35° to 200°F (-37.2° to 93.3°C)Weight .75 lbs (.34 kg)Operating Fluid Media General Purpose Hydraulic FluidCavity SpecialCavity Form Tool (Finishing) T058Seal Kit Special

VALVE SPECIFICATIONS

Nominal Operating Voltage 12 VDC ±5%Pull-in Voltage 8.5 VDC at 212°F (100°C)Peak Voltage 25 VDC for 5 min at 50°F (10°C) Temperature Range -40°F to 230°F (-40°C) to (110°C)Coil Resistance 7.3 Ohm ±5% at 68°F (20°C)Coil Termination AMP Superseal - IntegralConnector Color Black

COIL SPECIFICATIONS

Page 197: SOLENOID OPERATED DIRECTIONAL … 1000 38 69 7/8-14 DE-S2F SD18 2 WAY 2 POSITION NORMALLY CLOSED POPPET VALVES SLID PRATD DIRTIAL TRLS Page SD3 Via Malavolti, 36 • 41122 Modena •

SOLENOID OPERATED DIRECTIONAL CONTROLS

Page SD217

Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512 mail: [email protected] • www.tecnord.com

4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 mail: [email protected] • www.delta-power.com

WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken without independent study, evaluation, and testing for suitability.

W 2

0 /

2018

IG-S4A-58-MP12-A

DIMENSIONS

ORDERING INFORMATION

1.49 [37.8]

2.66 [67.5]

2.44 [62.0]

5.10 [129.5]

.12 [3.0]

1.38 [35.0]

.79 [20.0]

DIMENSIONS FOR REFERENCE ONLY

2.67 [67.8]

2.07 [52.6]

.83 [21.0]

1.45 [36.8]

.63 [15.9]

.69 [17.5]

.94 [23.8]

1.50 [38.0]

.75 [19.1]

.11 [2.8]

.94 [23.8]

1.59 [40.5]

2.20 [55.9]

2.59 [65.8]

2.79 [70.8]

FOR SPECIFIC CAVITY INFORMATION CONSULT FACTORY

Page 198: SOLENOID OPERATED DIRECTIONAL … 1000 38 69 7/8-14 DE-S2F SD18 2 WAY 2 POSITION NORMALLY CLOSED POPPET VALVES SLID PRATD DIRTIAL TRLS Page SD3 Via Malavolti, 36 • 41122 Modena •

SOLENOID OPERATED DIRECTIONAL CONTROLS

Page SD218

W 20 / 2018

Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512 mail: [email protected] • www.tecnord.com

4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 mail: [email protected] • www.delta-power.com

WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken without independent study, evaluation, and testing for suitability.