3
Inline Valves IV Nominal diameter 3 mm Solenoid Valves Schmalz – The Company Vacuum Suction Cups Special Grippers Gripping Systems Clamping Systems Mounting Elements Vacuum Generators Valve Technology Switches and Monitoring Filters and Connections Services Contact Glossary Index of Products Suitability for Industry Specific Applications Applications Inline Valves IV • Inline valve for deactivation of unused suction cups • Individual control of the suction cups in a "vacuum carpet", e.g. when order picking • System monitoring in vacuum spiders by activation and deactivation of suction cups System Design Inline Valves IV Design • Attachment facility for vacuum sensor • External body made of aluminum (2) • Integrated filter (3) for ventilation • 4-pin M8 connector (1) • Nominal diameter 3 mm; nominal flow rate 2 m³/h Suction cups with inline valves IV being used for handling carbody parts Our Highlights... Your Benefits... • Direct mounting in a suction cup • Individual control of single suction cups • Compact construction, simple installation • Minimum space requirements; simple installation • Integrated filter screen to protect against dirt • Increased functional safety • Decentralized vacuum control and system monitoring with a valve and an optional mini sensor • Improved process reliability and reduced standstill times of vacuum systems WWW.SCHMALZ.COM/IV 563

Solenoid Valves Inline Valves IV - pimmedia.schmalz.com · Inline Valves IV Nominal diameter 3 mm Solenoid Valves Schmalz – The Company Vacuum Suction Cups Special Grippers Gripping

  • Upload
    builiem

  • View
    238

  • Download
    0

Embed Size (px)

Citation preview

Inline Valves IVNominal diameter 3 mm

Solenoid Valves

Schm

alz

– Th

e Co

mpa

nyV

acuu

m

Suct

ion

Cups

Spec

ial

Grip

pers

Grip

ping

Sy

stem

sCl

ampi

ng

Syst

ems

Mou

ntin

g El

emen

tsV

acuu

m

Gen

erat

ors

Valv

e Te

chno

logy

Switc

hes a

nd

Mon

itorin

gFi

lters

and

Co

nnec

tions

Serv

ices

Cont

act

Glo

ssar

yIn

dex

of

Prod

ucts

Suitability for Industry Specific Applications

Applications

Inline Valves IV

• Inline valve for deactivation of unused suction cups• Individual control of the suction cups in a "vacuum carpet",

e.g. when order picking• System monitoring in vacuum spiders by activation and

deactivation of suction cups

System Design Inline Valves IV

Design

• Attachment facility for vacuum sensor • External body made of aluminum (2)• Integrated filter (3) for ventilation• 4-pin M8 connector (1)• Nominal diameter 3 mm; nominal flow rate 2 m³/h

Suction cups with inline valves IV being used for handling carbody parts

Our Highlights... Your Benefits...

• Direct mounting in a suction cup

• Individual control of single suction cups

• Compact construction, simple installation

• Minimum space requirements; simple installation

• Integrated filter screen to protect against dirt

• Increased functional safety

• Decentralized vacuum control and system monitoring with a valve and an optional mini sensor

• Improved process reliability and reduced standstill times of vacuum systems

WWW.SCHMALZ.COM/IV 563

00_en-EN_558-597_en-EN.indd 563 14.06.2018 14:36:01

PA

0102

2672

_003

-686

_en-

EN

.pdf

PA

0102

2672

_003

-686

_en-

EN

.pdf

PA01022672_003-686_en-EN.pdf

PA01022672_003-686_en-EN.pdf

Inline Valves IVNominal diameter 3 mm

Solenoid Valves

WWW.SCHMALZ.COM/IV

Schm

alz

– Th

e Co

mpa

nyV

acuu

m

Suct

ion

Cups

Spec

ial

Grip

pers

Grip

ping

Sy

stem

sCl

ampi

ng

Syst

ems

Mou

ntin

g El

emen

tsV

acuu

m

Gen

erat

ors

Valv

e Te

chno

logy

Switc

hes a

nd

Mon

itorin

gFi

lters

and

Co

nnec

tions

Serv

ices

Cont

act

Glo

ssar

yIn

dex

of

Prod

ucts

Inline valve IV is delivered as a ready-to-connect product (without connection cable). Available accessories: connection cable, vacuum sensors

Designation Code Inline Valves IV

IV – 3 – 3/2 – G3/8-IG – G3/8-AG – 24V-DC1 2 3 4 5 6

1 – Abbreviated designation

Code Version

IV IV

4 – Vacuum connection

Code Connection

G1/4-IG G1/4-IG (IG = female (F))

G3/8-IG G3/8-IG

2 – Nozzle size

Code Nozzle size in mm

3 3

5 – Suction cup connection

Code Connection

G3/8-AG G3/8-AG (AG = male (M))

3 – Variant

Code Type

3/2 3/2-way valve

6 – Voltage

Code Voltage in V

24V-DC Direct current

Type Part no.

IV 3 3/2 G1/4-IG G3/8-AG 24V-DC 10.05.01.00173

IV 3 3/2 G3/8-IG G3/8-AG 24V-DC 10.05.01.00172

Ordering Data Inline Valves IV

Type* Part no.

Connection cable, M8 4-pole, 5 m, PUR, straight ASK B-M8-4 5000 K-4P 10.06.02.00031

Connection cable, M8 4-pole, 5 m, PUR, 90° ASK WB-M8-4 5000 K-4P 10.06.02.00032

Vacuum sensor analog VS-V-SA M5-AG 10.06.02.00224

Vacuum sensor digital VS-V-SD 60 M5-AG 10.06.02.00257

*See section "Switches and system monitoring" for further details

Ordering Data Accessories Inline Valves IV

Type Nominal size

[mm]

Control valve Voltage Nominal flow rate

[l/min]

Nominal flow rate

[m³/h]

Input DC

[W]

Weight

[kg]

IV 3 3/2 G1/4-IG G3/8-AG 24V-DC 3 Normally open 24V - DC V 34 2 4.5 0.074

IV 3 3/2 G3/8-IG G3/8-AG 24V-DC 3 Normally open 24V - DC V 34 2 4.5 0.074

Technical Data Inline Valves IV

564

00_en-EN_558-597_en-EN.indd 564 14.06.2018 14:36:01

PA

0102

2672

_003

-686

_en-

EN

.pdf

PA

0102

2672

_003

-686

_en-

EN

.pdf

PA01022672_003-686_en-EN.pdf

PA01022672_003-686_en-EN.pdf

Inline Valves IVNominal diameter 3 mm

Solenoid Valves

WWW.SCHMALZ.COM/IV

Schm

alz

– Th

e Co

mpa

nyV

acuu

m

Suct

ion

Cups

Spec

ial

Grip

pers

Grip

ping

Sy

stem

sCl

ampi

ng

Syst

ems

Mou

ntin

g El

emen

tsV

acuu

m

Gen

erat

ors

Valv

e Te

chno

logy

Switc

hes a

nd

Mon

itorin

gFi

lters

and

Co

nnec

tions

Serv

ices

Cont

act

Glo

ssar

yIn

dex

of

Prod

ucts

Design Data Inline Valves IV

IV

Type G1 G2 G3 G4 H

[mm]

LG1

[mm]

LG2

[mm]

LG3

[mm]

SW1

[mm]

IV 3 3/2 G1/4-IG G3/8-AG 24V-DC G1/4“-F G3/8“-M M8-M M5-F 51 9 9 6.5 24

IV 3 3/2 G3/8-IG G3/8-AG 24V-DC G3/8“-F G3/8“-M M8-M M5-F 51 9 9 6.5 24

565

00_en-EN_558-597_en-EN.indd 565 14.06.2018 14:36:01

PA

0102

2672

_003

-686

_en-

EN

.pdf

PA

0102

2672

_003

-686

_en-

EN

.pdf

PA01022672_003-686_en-EN.pdf

PA01022672_003-686_en-EN.pdf