Upload
nguyenthuy
View
221
Download
3
Embed Size (px)
Citation preview
PENDANTDIRECT/INDIRECT LIGHTING
SINGLE UNITSCONTINUOUS RUNS
SHAPES
EM - R23
1/16
2016.07.28
Specification Sheet lumenline™ 2
5-year limited warranty.
Consult www.lumenpulse.com for our complete Standard Terms and Conditions of Sales.
© Copyright Lumenpulse 2016
1751 Richardson, Suite 1505 Montreal (Quebec) Canada H3K 1G6
1.877.937.3003 P.514.937.3003 F. [email protected]
Lumenpulse reserves the right to make changes to this product at any time without prior notice and such modi�cation shall be effective immediately.
AIRCRAFT CABLELENGTH IS FIELD
ADJUSTABLE UP TO 250"
FRONT VIEW
SIDE VIEW
TOP VIEW, WIDE FLOOD OPTIC SHOWN
BOTTOM VIEW, WIDE FLOOD OPTIC SHOWN
[68mm]
11 16
"2
[115mm]
9 16
"4
[317mm, 616mm, 916mm, 1216mm, 1518mm, 1818mm, 2119mm, 2419mm]
1 2
" 1 4
"12 , 24 1 ", 36 7 8 16
", 47 3 4
", 59 9 16
", 71 3 8
", 83 1 4
", 95
Direct wide flood
Direct trueasymmetric wallwash
Direct narrow flood
OpticDelivered
output [lm/ft]Lumens/
Watt [lm/W]
492
391
398
Indirect batwing wide 479
87
71
73
Indirect wide flood* 522 93
88
Performance summaryBased on RO, all color temperatures,
White painted louver for NF and WW optics.
Photometric performance is measured incompliance with IESNA LM-79-08.
*Estimated. Consult website for latest ies files.
FEATURES AND BENEFITS
Physical :• Aluminum extruded housing, 2” wide• Available in 1’, 2’, 3’, 4’, 5’, 6’, 7’ or 8’ sections• Continuous runs available in 1’ increments• Durable polyester powder coat finish• Wide flood, true asymmetric wallwash or narrow flood direct lighting optics• Batwing wide or wide flood indirect lighting optics• Wallwash and narrow flood optics provided with white painted louvers • Black painted or semi-specular louver finish optional• Wide flood optic provided with frosted extruded acrylic lens • Tool-less system for reflector assembly and control gear access• Suitable for use with drywall, grid and metal pan ceilings (millwork ceilings)• Aircraft cable adjustable suspension system• Lit and unlit joiners available for custom configurations• Compatible with motion sensors• Dry location only• IK05 rated Performance :• Available in 2700K, 3000K, 3500K, 4000K or RGB color mixing for direct and indirect lighting• Binning within a 3 step MacAdam ellipse• Lumen maintenance: 100,000 hrs [L70 @ 25° C]• Lumen measurements comply with LM - 79 - 08 standard• Resolution per foot or per fixture (configured with LumenID V3 software & DMX/RDM)• Operating temperatures: -25° C to 50° C [-13F to 122F]
Electrical :• Line voltage luminaire for 100 to 347V• Standard white cable and canopy, consult factory for other options• 6W/ft Regular Output version, direct or indirect lighting• 12W/ft High Output version, direct or indirect lighting• Dimming options for white light: 0-10 volt, DMX/RDM enabled, DALI, Lumentalk or Lutron® EcoSystem® Enabled• 6W/ft optional RGB source, DMX/RDM enabled• Quick connectors for continuous runs
Client Project name
Order# Type Qty
Narrow flood(30˚ x 60˚)
Wide flood (100˚)Direct
Wide flood (100˚)Indirect
Batwing wide (170˚)
True asymmetricwallwash
CERTIFICADO No.05884,05885
RETILAP
IK05
PENDANTDIRECT/INDIRECT LIGHTING
SINGLE UNITSCONTINUOUS RUNS
SHAPES
EM - R23
2/16
2016.07.28
Specification Sheet lumenline™ 2
5-year limited warranty.
Consult www.lumenpulse.com for our complete Standard Terms and Conditions of Sales.
© Copyright Lumenpulse 2016
1751 Richardson, Suite 1505 Montreal (Quebec) Canada H3K 1G6
1.877.937.3003 P.514.937.3003 F. [email protected]
Lumenpulse reserves the right to make changes to this product at any time without prior notice and such modi�cation shall be effective immediately.
PHOTOMETRIC INFORMATION - DIRECT LIGHTING OPTICS
WFL - Wide flood (100°), all color temperatures
Bottom view,frosted lens
1969
357
HORO
Delivered output, 4f fixture [lm]
White light
RGB
3727
N/A
CRI Value: 80+
WW - True asymmetric wallwash, all color temperaturesNot available for RGB or lit joiners
Bottom view,wallwash louver
NF - Narrow flood (30°x 60°), all color temperaturesNot available for RGB or lit joiners
Bottom View,narrow flood louver
1591
1042*
HORO
Delivered output, 4f fixture [lm]
White louver
Black louver
Semi-specular
2957
1894
1829* 3325
CRI Value: 80+
Candlepower distribution4ft, HO
439
878
1317
1756
1564
1174*
HORO
Delivered output, 4f fixture [lm]
White louver
Black louver
Semi-specular
2783
2135
- -
CRI Value: 80+
4ft, HOBlack louver
903
1805
2708
3610
Candlepower distribution4ft, HOWhite louver
964
1928
2891
3855
0˚-180˚ 90˚-270˚
Semi-specular louver
1014
2028
3042
4056
0˚-180˚ 90˚-270˚
Black louver
802
1605
2407
3209
0˚-180˚ 90˚-270˚
Candlepower distribution,4ft, HOWhite louver
878
1755
2633
3510
Notes:*Estimated. Consult website for latest ies fi les.
PENDANTDIRECT/INDIRECT LIGHTING
SINGLE UNITSCONTINUOUS RUNS
SHAPES
EM - R23
3/16
2016.07.28
Specification Sheet lumenline™ 2
5-year limited warranty.
Consult www.lumenpulse.com for our complete Standard Terms and Conditions of Sales.
© Copyright Lumenpulse 2016
1751 Richardson, Suite 1505 Montreal (Quebec) Canada H3K 1G6
1.877.937.3003 P.514.937.3003 F. [email protected]
Lumenpulse reserves the right to make changes to this product at any time without prior notice and such modi�cation shall be effective immediately.
PHOTOMETRIC INFORMATION - INDIRECT LIGHTING OPTICS
WFL - Wide flood (100°), all color temperatures*
Top view,clear lens
Candlepower distribution4ft, HO
2025
480
HORO
Delivered output, 4f fixture [lm]
White light
RGB
3969
N/A
CRI Value: 80+
BWW - Batwing wide (170°), all color temperatures
Top view,Batwing optic
Candlepower distribution4ft, HO
392
785
1177
1569 1915
-
HORO
Delivered output, 4f fixture [lm]
White light
RGB
3501
N/A
CRI Value: 80+
404
809
1213
1618
Notes:*Estimated. Consult website for latest ies fi les.
PENDANTDIRECT/INDIRECT LIGHTING
SINGLE UNITSCONTINUOUS RUNS
SHAPES
EM - R23
4/16
2016.07.28
Specification Sheet lumenline™ 2
5-year limited warranty.
Consult www.lumenpulse.com for our complete Standard Terms and Conditions of Sales.
© Copyright Lumenpulse 2016
1751 Richardson, Suite 1505 Montreal (Quebec) Canada H3K 1G6
1.877.937.3003 P.514.937.3003 F. [email protected]
Lumenpulse reserves the right to make changes to this product at any time without prior notice and such modi�cation shall be effective immediately.
LOUVER INSTALLATION DETAIL
BATWING WIDE OPTIC - INSTALLATION GUIDELINES
BOTTOM VIEW
Always position louver blades toward the wall
BOTTOM VIEW
Symmetrical louver design, no specific orientation required
Suggested setback 1/7 of the wall height.Example: 1' 5" [432mm] setback for a10ft [3048mm] wall.
True Asymmetric Wallwash
Narrow Flood
Standard feeding side(left hand side when facing the wall)
Minimum mounting height from ceiling is 12" [305mm].
FRONT VIEW
TOP VIEW
TOP VIEW
12ft [3.6m] spacing between rows.
PENDANTDIRECT/INDIRECT LIGHTING
SINGLE UNITSCONTINUOUS RUNS
SHAPES
EM - R23
5/16
2016.07.28
Specification Sheet lumenline™ 2
5-year limited warranty.
Consult www.lumenpulse.com for our complete Standard Terms and Conditions of Sales.
© Copyright Lumenpulse 2016
1751 Richardson, Suite 1505 Montreal (Quebec) Canada H3K 1G6
1.877.937.3003 P.514.937.3003 F. [email protected]
Lumenpulse reserves the right to make changes to this product at any time without prior notice and such modi�cation shall be effective immediately.
SUSPENSION SYSTEM MOUNTING ACCESSORIESIncluded
Drywall ceiling accessories
Non-feeder canopy[51mm]
"2
1/4-20 hardware(by others)
Feeder canopyPower only
[127mm]"5
4"x4" j-boxrequired(by others)
Feeder canopyPower and data
[127mm]"5
4"x4" j-boxrequired(by others)
Non-feeder canopy
T-bar mounting clip and fastner included
[51mm]"2
Suspended ceiling accessories
Feeder canopyPower and data
[127mm]"5
Suspended ceilingj-box (by others)
T-bar mounting clip and fastner included
[127mm]"5
Suspended ceilingj-box (by others)
Feeder canopyPower only
T-bar mounting clip and fastner included
*In continuous runs, a minimum of 1 hanging point per fixture is required.
PENDANTDIRECT/INDIRECT LIGHTING
SINGLE UNITSCONTINUOUS RUNS
SHAPES
EM - R23
6/16
2016.07.28
Specification Sheet lumenline™ 2
5-year limited warranty.
Consult www.lumenpulse.com for our complete Standard Terms and Conditions of Sales.
© Copyright Lumenpulse 2016
1751 Richardson, Suite 1505 Montreal (Quebec) Canada H3K 1G6
1.877.937.3003 P.514.937.3003 F. [email protected]
Lumenpulse reserves the right to make changes to this product at any time without prior notice and such modi�cation shall be effective immediately.
LIT JOINER TYPES AND DIMENSIONSRefer to the SHAPE ordering pageNot available for true asymmetric wallwash and narrow flood optics
3138
"
[797mm]
14 38"
[365mm] 14 38
"
[365mm]
14 38"
[365mm]14 3
8"
[365mm]
31 38
"
[797mm]
17"[432mm]
14 38 "
[365mm]
HCNRHorizontal 90o
Used to build square, rectangle and “L” shapes(Equivalent of a 4’ fixture)
TCNRTee 90o
(Equivalent of a 6’ fixture)
CCNRCross 90o
(Equivalent of an 8’ fixture)
TOP VIEW TOP VIEW
TOP VIEW
PENDANTDIRECT/INDIRECT LIGHTING
SINGLE UNITSCONTINUOUS RUNS
SHAPES
EM - R23
7/16
2016.07.28
Specification Sheet lumenline™ 2
5-year limited warranty.
Consult www.lumenpulse.com for our complete Standard Terms and Conditions of Sales.
© Copyright Lumenpulse 2016
1751 Richardson, Suite 1505 Montreal (Quebec) Canada H3K 1G6
1.877.937.3003 P.514.937.3003 F. [email protected]
Lumenpulse reserves the right to make changes to this product at any time without prior notice and such modi�cation shall be effective immediately.
CNRCorner 90o
TEETee 90o
LNRLinear 180o
CROCross 90o
UNLIT JOINER TYPES AND DIMENSIONSRefer to the SHAPE ordering page
AA
CC
DD
BB*
FIRST OR END OF RUN - Mounting points on fixture and joiner*N.B. Mounting point corresponding to feeder cable location cannot be moved.
MIDDLE OF RUN - Mounting points on joiners
FF GG HH
1 2 "
[13mm]
11132 "
[34mm]
CONTINUOUS RUN - Mounting points on fixtures and joinersMIDDLE OF RUN
Overall length(AA)
Center to center of mounting points (BB)
Minimum Maximum
38 1/2'' [977mm]3'
26 5/8'' [677mm]2'14 7/8'' [379mm]1'
50 5/16' [1279mm]
5' 62 1/16'' [1578mm]
6'
85 13/16'' [2181mm]7'
73 15/16'' [1879mm]
97 5/8'' [2481mm]
36 7/16'' [926mm]
24 5/8'' [628mm]
12 7/8'' [327mm]
48 5/16' [1227mm]
60 1/16'' [1526mm]
83 13/16'' [2129mm]
71 15/16'' [1828mm]
95 5/8'' [2429mm]
30 7/16'' [773mm]
20 5/8'' [524mm]
11'' [280mm]
36 5/16' [923mm]
48 1/16'' [1221mm]
67 13/16'' [1723mm]
55 15/16'' [1421mm]
71 5/8'' [1820mm]8'
4'
Fixturelength
Overall length(CC)
Center to center of mounting points (DD)
40 7/8'' [1039mm]3'
29 1/16'' [739mm]2'17 5/16'' [440mm]1'
52 3/4' [1340mm]
5' 64 1/2'' [1639mm]
6'
88 1/4'' [2242mm]7'
76 3/8'' [1940mm]
100 1/16'' [2542mm]
38 3/16'' [970mm]
26 3/8'' [670mm]
14 5/8'' [372mm]
50 1/16' [1272mm]
61 13/16'' [1571mm]
85 9/16'' [2174mm]
73 11/16'' [1872mm]
97 3/8'' [2474mm]8'
4'
35 1/8'' [892mm]3'
23 5/16'' [592mm]2'11 9/16'' [293mm]1'
47'' [1194mm]
5' 58 3/4'' [1492mm]
6'
82 1/2'' [2095mm]7'
70 5/8'' [1794mm]
94 5/16'' [2395mm]
38 5/8'' [981mm]
25 13/16'' [656mm]
15 1/16'' [383mm]
50 1/2' [1283mm]
62 1/4'' [1581mm]
86'' [2184mm]
74 1/8'' [1283mm]
97 13/16'' [2484mm]8'
4'
(FF) (GG) (HH)
35 1/2'' [902mm]
23 11/16'' [602mm]
11 15/16'' [303mm]
47 3/8'' [1203mm]
59 1/8'' [1502mm]
82 7/8'' [2105mm]
71'' [1803mm]
94 11/16'' [2405mm]
Fixturelength
Fixturelength
Center to center of mounting points
UNLIT JOINER MOUNTING POINT LOCATIONS
*Consult factory for shapes requiring the LNR joiner.
PENDANTDIRECT/INDIRECT LIGHTING
SINGLE UNITSCONTINUOUS RUNS
SHAPES
EM - R23
8/16
2016.07.28
Specification Sheet lumenline™ 2
5-year limited warranty.
Consult www.lumenpulse.com for our complete Standard Terms and Conditions of Sales.
© Copyright Lumenpulse 2016
1751 Richardson, Suite 1505 Montreal (Quebec) Canada H3K 1G6
1.877.937.3003 P.514.937.3003 F. [email protected]
Lumenpulse reserves the right to make changes to this product at any time without prior notice and such modi�cation shall be effective immediately.
ACCESSORIESOrder separately
Control Systems:LTO2 Lumentouch is a wall mount DMX 512 controller keypad.
LCU Lumencue is a USB / mini SD DMX 512 controller.
LID LumenID is a diagnostic and addressing DMX 512 controller.It must be specifi ed on all DMX applications.Refer to LID specifi cation sheet for details.
LTN Lumentone is a simple pre-programmed DMX 512 controllerwith a push button rotary dial and live feedback.
Control Boxes:CBX DMX/RDM control box.
Up to six power and data outputs to fi xtures or fi xture runs.Ethernet enabled option.Refer to CBX specifi cation sheet for details.
PENDANTDIRECT/INDIRECT LIGHTING
SINGLE UNITSCONTINUOUS RUNS
SHAPES
EM - R23
9/16
2016.07.28
Specification Sheet lumenline™ 2
5-year limited warranty.
Consult www.lumenpulse.com for our complete Standard Terms and Conditions of Sales.
© Copyright Lumenpulse 2016
1751 Richardson, Suite 1505 Montreal (Quebec) Canada H3K 1G6
1.877.937.3003 P.514.937.3003 F. [email protected]
Lumenpulse reserves the right to make changes to this product at any time without prior notice and such modi�cation shall be effective immediately.
Reflector 2
1ftIndirectDirect
2ft
3ft
4ft
5ft
6ft
7ft
8ft
Reflector 24
2
Reflector 11
3
Reflector 2
Reflector 2
Reflector 4
Reflector 11 2
Resolution per foot: each foot is addressed independently
SINGLE UNITS
1ft 2ft 3ft 4ft 5ft 6ft 7ft 8ft2 4 6 8 10 12 14 16WH/WH4WH/RGB 8 12 16 20 24 28 32
HCNR TCNR CCNR6
109
151220
Lit joinersSingle units
HCNR TCNR CCNR24
35
35
Lit joinersSingle units1ft to 4ft 5ft to 8ft
2 4WH/WH4WH/RGB 8
Resolution per fixture: each reflector is addressed independently
BOARD AND REFLECTOR LAYOUT PER FIXTURE LENGTH
Total number of DMX addresses required
per fixture(Direct/Indirect)
Total number of DMX addresses required
per fixture(Direct/Indirect)
6 5 4
Reflector 11 2 3
Reflector 38 7 6
Reflector 39 8 7
Reflector 311 10 9 8
Reflector 312 11 10 9
8 7 6 5
Reflector 11 2 3 4
109
Reflector 2Reflector 11 2 3 45
Reflector 41210 11
Reflector 11 2 3
Reflector 246 5
Reflector 41412 13
Reflector 11 2 3 4
Reflector 257 6
Reflector 415 1613 14
Reflector 11 2 3 4
Reflector 26 58 7
IndirectDirect
IndirectDirect
IndirectDirect
IndirectDirect
IndirectDirect
IndirectDirect
IndirectDirect
RESOLUTION DETAILSApplicable for DMX/RDM control option only.Fixture resolution can be configured on-site within the LumenID V3 software. A DMX/RDM enabled CBX is required.
PENDANTDIRECT/INDIRECT LIGHTING
SINGLE UNITSCONTINUOUS RUNS
SHAPES
EM - R23
10/16
2016.07.28
Specification Sheet lumenline™ 2
5-year limited warranty.
Consult www.lumenpulse.com for our complete Standard Terms and Conditions of Sales.
© Copyright Lumenpulse 2016
1751 Richardson, Suite 1505 Montreal (Quebec) Canada H3K 1G6
1.877.937.3003 P.514.937.3003 F. [email protected]
Lumenpulse reserves the right to make changes to this product at any time without prior notice and such modi�cation shall be effective immediately.
RESOLUTION DETAILS - continued
LIT JOINERS IN SHAPES
Reflector 1Re
flect
or 2
1 2
3
4
Reflector 11 2
Reflector 3
Refle
ctor
2
3
4
HCNRHorizontal 90°
TCNRTee 90°
CCNRCross 90°
Reflector 11 2
Reflector 3
Refle
ctor
2
3
4
Refle
ctor
4
8
7
Reflector 3
Refle
ctor
4
5
6
Reflector 5 Reflector 69
Refle
ctor
4
7
Reflector 6 Reflector 812
Refle
ctor
5
9
Refle
ctor
7
11
Direct Indirect
Direct Indirect
Direct Indirect
8
10
56
56
PENDANTDIRECT/INDIRECT LIGHTING
SINGLE UNITSCONTINUOUS RUNS
SHAPES
EM - R23
11/16
2016.07.28
Specification Sheet lumenline™ 2
5-year limited warranty.
Consult www.lumenpulse.com for our complete Standard Terms and Conditions of Sales.
© Copyright Lumenpulse 2016
1751 Richardson, Suite 1505 Montreal (Quebec) Canada H3K 1G6
1.877.937.3003 P.514.937.3003 F. [email protected]
Lumenpulse reserves the right to make changes to this product at any time without prior notice and such modi�cation shall be effective immediately.
RESOLUTION DETAILS - continued
Example: DMX addresses, resolution per foot, 8ft fixture and CCNR lit joiner
Example: DMX addresses, resolution per fixture, 8ft fixture and CCNR lit joiner
410, 11, 12
822, 23, 24
24, 5, 6
616, 17, 18
37, 8, 9
719, 20, 21
513, 14, 15
11, 2, 3
25, 26, 279
37, 38, 3913
31, 32, 3311
43, 44, 4515
28, 29, 3010
40, 41, 4214
46, 47, 4816
34, 35, 3612
8ftReflector 3 Reflector 4
Reflector 1 Reflector 2
IndirectDirect
Reflector 6 Reflector 8
Refle
ctor
5Re
flect
or 7
IndirectDirectCCNRCross 90°
CCNRCross 90°
Reflector 1 Reflector 3
Refle
ctor
2Re
flect
or 4
1028, 29, 30
925, 26, 27
1234, 35, 36
11, 2, 3
24, 5, 6
1131, 32, 33
11, 2, 3
24, 5, 6
7, 8, 93
10, 11, 124
8ftReflector 3 Reflector 4
Reflector 1 Reflector 2
IndirectDirect
Reflector 6 Reflector 8
Refle
ctor
5Re
flect
or 7
IndirectDirectReflector 1 Reflector 3
Refle
ctor
2Re
flect
or 4
11, 2, 3
34, 5, 6
21, 2, 3
410, 11, 12
13, 14, 156
16, 17, 185
37, 8, 9
719, 20, 21
822, 23, 24
RGB versionWhite light version
PENDANTDIRECT/INDIRECT LIGHTING
SINGLE UNITSCONTINUOUS RUNS
SHAPES
EM - R23
12/16
2016.07.28
Specification Sheet lumenline™ 2
5-year limited warranty.
Consult www.lumenpulse.com for our complete Standard Terms and Conditions of Sales.
© Copyright Lumenpulse 2016
1751 Richardson, Suite 1505 Montreal (Quebec) Canada H3K 1G6
1.877.937.3003 P.514.937.3003 F. [email protected]
Lumenpulse reserves the right to make changes to this product at any time without prior notice and such modi�cation shall be effective immediately.
TYPICAL WIRING DIAGRAMS
100-347V*To next fixture
100-347V* Input
To fixture
Ground greenNeutral white
Line black
Canopy
Junction box(by others)
100-347V*
100-347V*
From Dimmer or Controller
To fixture
100-347V*& Data output To next fixture
100-347V* Input
Ground greenNeutral white
Line black
Canopy
Data- orangeData+ red/purple Junction box
(by others)
Data input
Single units, daisy chain layout0-10V, DALI or EcoSystem® control options
Single units, daisy chain configurationNon-dimming or Lumentalk control options Non-dimming or Lumentalk wiring detail
0-10V, DALI or EcoSystem® wiring detail
1x DALI address per reflector.Total number of DALI addresses required per fixture:
1x EcoSystem® address per reflector.Total number of EcoSystem® addresses required per fixture:
HCNR TCNR CCNR2 3 3
Lit joinersSingle units1ft to 4ft 5ft to 8ft
2 4WH/WHHCNR TCNR CCNR
2 3 3
Lit joinersSingle units2ft to 4ft 5ft to 8ft
2 4WH/WH
*Lumentalk and RGB options not available with 347V.
WIRE COLOR / USE
GREEN GROUNDWHITE NEUTRALBLACK LINE 100-347V
ORANGEDATA +RED/ PURPLEDATA -
Maximum run lengths - 7A maximum with 10ft [3m] fixture cord
Configuration/Voltage 100V 120V 208V, 220V, 240V, 277V, 347V
47ft [14.3m]
32ft [9.8m]HO/RO
RO/RO 56ft [17.1m]
36ft [11m]
63ft [19.2m]
63ft [19.2m]
Notes: 1 Maximum run length calculations are typically based on 4ft [1.2m].Each lumenline reflector requires 1x DMX/RDM or DALI address: a lumenline fixture can contain multiple reflectors,refer to Board and Reflector Layout for details. Consult factory for specific applications.
PENDANTDIRECT/INDIRECT LIGHTING
SINGLE UNITSCONTINUOUS RUNS
SHAPES
EM - R23
13/16
2016.07.28
Specification Sheet lumenline™ 2
5-year limited warranty.
Consult www.lumenpulse.com for our complete Standard Terms and Conditions of Sales.
© Copyright Lumenpulse 2016
1751 Richardson, Suite 1505 Montreal (Quebec) Canada H3K 1G6
1.877.937.3003 P.514.937.3003 F. [email protected]
Lumenpulse reserves the right to make changes to this product at any time without prior notice and such modi�cation shall be effective immediately.
TYPICAL WIRING DIAGRAMS - continued
To fixture
Data- orange
Canopy
Data+ red/purple
From CBX100-347V*
& Data input
Ground greenNeutral white
Line black
Junction box(by others)
For stable DMX/RDM data signal, do not split data wires after the CBX.
100-347V*
CBX
Data input
100-347V* & Data
Single units, star layoutDMX/RDM control option DMX/RDM wiring detail
Non-dimming & Lumentalk control optionsContinuous run, single feed
Quick connectors
100-347V*
Non-dimming or Lumentalk wiring detail
100-347V*To next fixture
To next fixture
100-347V* Input
To fixture
Ground greenNeutral white
Line black
Canopy
Junction box(by others)
*Lumentalk and RGB options not available with 347V.
WIRE COLOR / USE
GREEN GROUNDWHITE NEUTRALBLACK LINE 100-347V
ORANGEDATA +RED/ PURPLEDATA -
Maximum run lengths - 7A maximum with 10ft [3m] fixture cord
Configuration/Voltage 100V 120V 208V, 220V, 240V, 277V, 347V
47ft [14.3m]
32ft [9.8m]HO/RO
RO/RO 56ft [17.1m]
36ft [11m]
63ft [19.2m]
63ft [19.2m]
Notes: 1 Maximum run length calculations are typically based on 4ft [1.2m].Each lumenline reflector requires 1x DMX/RDM or DALI address: a lumenline fixture can contain multiple reflectors,refer to Board and Reflector Layout for details. Consult factory for specific applications.
PENDANTDIRECT/INDIRECT LIGHTING
SINGLE UNITSCONTINUOUS RUNS
SHAPES
EM - R23
14/16
2016.07.28
Specification Sheet lumenline™ 2
5-year limited warranty.
Consult www.lumenpulse.com for our complete Standard Terms and Conditions of Sales.
© Copyright Lumenpulse 2016
1751 Richardson, Suite 1505 Montreal (Quebec) Canada H3K 1G6
1.877.937.3003 P.514.937.3003 F. [email protected]
Lumenpulse reserves the right to make changes to this product at any time without prior notice and such modi�cation shall be effective immediately.
TYPICAL WIRING DIAGRAMS - continued
Continuous run, multiple feeds
DMX/RDM control option*Continuous run, single feed
Circuit #1100-347V*
Data input
100-347V*& Data input
100-347V* & Data input
Circuit #2100-347V*
Data
CBXCBX
For stable DMX/RDM data signal,do not split data wires after the CBX.
For stable DMX/RDM data signal,do not split data wires after the CBX.
Quick connectors
100-347V*& Data
To fixture
Data- orange
Canopy
Data+ red/purple
From CBX100-347V*
& Data intput
Ground greenNeutral white
Line black
Junction box(by others)
DMX/RDM wiring detail
100-347V* CBXData input
0-10V, DALI or or EcoSystem® control optionsContinuous run, single feed
Quick connectors
100-347V*Data input
From Controller
To fixture
100-347V*& Data output To next fixture
100-347V*Input
Ground greenNeutral white
Line black
Canopy
Data- orangeData+ red/purple Junction box
(by others)
0-10V, DALI or EcoSystem® wiring detail
1x DALI address per reflector.Total number of DALI addresses required per fixture:
1x EcoSystem® address per reflector.Total number of EcoSystem® addresses required per fixture:
HCNR TCNR CCNR2 3 3
Lit joinersSingle units1ft to 4ft 5ft to 8ft
2 4WH/WHHCNR TCNR CCNR
2 3 3
Lit joinersSingle units2ft to 4ft 5ft to 8ft
2 4WH/WH
*Lumentalk and RGB options not available with 347V.
EM - R23
15/16
2016.07.28
Specification Sheet lumenline™ 2
5-year limited warranty.
Consult www.lumenpulse.com for our complete Standard Terms and Conditions of Sales.
© Copyright Lumenpulse 2016
1751 Richardson, Suite 1505 Montreal (Quebec) Canada H3K 1G6
1.877.937.3003 P.514.937.3003 F. [email protected]
Lumenpulse reserves the right to make changes to this product at any time without prior notice and such modi�cation shall be effective immediately.
PENDANTDIRECT/INDIRECT LIGHTING
SINGLE UNITSCONTINUOUS RUNS
HOW TO ORDER - SINGLE UNITS AND CONTINUOUS RUNS
1 Housing:
LLI2P - Lumenline™ Pendant 2" wide
2 Light Direction:
DI - Direct/Indirect lighting
3 Voltage:100 - 100 volts120 - 120 volts208 - 208 volts220 - 220 volts
240 - 240 volts277 - 277 volts347 - 347 volts1
4 Length:SU1 - Single Unit 12 1/2 inches (317mm)SU2 - Single Unit 24 1/4 inches (616mm)SU3 - Single Unit 36 1/16 inches (916mm)SU4 - Single Unit 47 7/8 inches (1216mm) SU5 - Single Unit 59 3/4 inches (1518mm)SU6 - Single Unit 71 9/16 inches (1818mm)SU7 - Single Unit 83 3/8 inches (2119mm)SU8 - Single Unit 95 1/4 inches (2419mm)C__ - Continuous run, specify in 1’ increments.
5 Direct Lighting:
Output & Color temperature:dRO 27K - 2700K regular output 6W/ftdRO 30K - 3000K regular output 6W/ftdRO 35K - 3500K regular output 6W/ftdRO 40K - 4000K regular output 6W/ftdHO 27K - 2700K high output 12W/ft2
dHO 30K - 3000K high output 12W/ft2
dHO 35K - 3500K high output 12W/ft2
dHO 40K - 4000K high output 12W/ft2
dRO RGB - Tri-color red, green and blue direct lighting 6W/ft3
Optics:WFL - Wide flood, 100° distribution, frosted lens NF - Narrow flood, 30° x 60° distribution, highly reflective white painted
louver4
WW - True asymmetric wallwash, highly reflective white painted louver4
6 Indirect Lighting:
Output & Color temperature:iRO 27K - 2700K regular output 6W/ftiRO 30K - 3000K regular output 6W/ftiRO 35K - 3500K regular output 6W/ftiRO 40K - 4000K regular output 6W/ftiHO 27K - 2700K high output 12W/ft2
iHO 30K - 3000K high output 12W/ft2
iHO 35K - 3500K high output 12W/ft2
iHO 40K - 4000K high output 12W/ft2
iRO RGB - Tri-color red, green and blue indirect lighting 6W/ft3
Optics:WFL - Wide flood, 100° distribution, clear lensBWW - Batwing wide, 170° distribution
7 Control:NO - On/Off controlLT - Lumentalk5
DIM - 0-10V Dimming option6
DMX/RDM - DMX/RDM enabled7
DALI - DALI Dimming option8
ES - Lutron® EcoSystem® Enabled Dimming9
8 Mounting:ACC50 - Aircraft cable, 50" (field adjustable)ACC100 - Aircraft cable, 100" (field adjustable)ACC250 - Aircraft cable, 250" (field adjustable)
9 Finish:BK - Black Sandtex10
SI - Silver Sandtex10
WH - Smooth white10
CC - Custom color and finish (please specify RAL color)11
10 Option:BLL - Black painted louver12
SSL - Semi-specular louver12
Photometric performance will vary with black and semi-specular louveroptions, see Photometric Information pages for more information.
LLI2P DI 1 2 3 4 5 6 7 8 9 10
Notes:1 347V is not available for 1' [305mm] lengths. 347V is not available for RGB color option or LT control option. 2 High output direct lighting cannot be combined with high output indirect lighting. 3 RGB optionrequires DMX/RDM control to be specified in Control section. 4 Not available for RGB color option. 5 1% minimum dimming value. Available with white light only, not available for 1' [305mm] lengths.6 10% minimum dimming value. 7 1% minimum dimming value. Fixtures set to by fixture resolution (consult the Resolution Details pages for the number of DMX addresses per fixture length and type).8 1% minimum dimming value. Available with white light only. Consult Typical Wiring Diagram pages for the number of DALI addresses per fixture length and type. 9 1% minimum dimming value. Available withwhite light only, not available for 1' [305mm] lengths. Consult Typical Wiring Diagram pages for the number of EcoSystem® addresses per fixture length and type. 10 Standard white finish for cable and canopy,consult -factory for other options. 11 North American RAL colors specified with RAL number only are provided with a smooth/high-gloss finish. Please consult factory for other RAL textures and glosses, or tomatch alternate color charts. Final color matching results may vary.12 Available for WW and NF optics, not compatible with WFL option.
EM - R23
16/16
2016.07.28
Specification Sheet lumenline™ 2
5-year limited warranty.
Consult www.lumenpulse.com for our complete Standard Terms and Conditions of Sales.
© Copyright Lumenpulse 2016
1751 Richardson, Suite 1505 Montreal (Quebec) Canada H3K 1G6
1.877.937.3003 P.514.937.3003 F. [email protected]
Lumenpulse reserves the right to make changes to this product at any time without prior notice and such modi�cation shall be effective immediately.
PENDANTDIRECT/INDIRECT LIGHTING
SHAPESHOW TO ORDER - SHAPES
1 Housing:
LLI2P - Lumenline™ Pendant 2" wide
2 Light Direction:
DI - Direct/Indirect lighting
3 Voltage:100 - 100 volts120 - 120 volts208 - 208 volts220 - 220 volts
240 - 240 volts277 - 277 volts347 - 347 volts1
4 Length:IMPORTANT: Side length up to 20’ as a standard. Consult factory for any other shape requirements.
S__ - Square shape: specify side length (equal sides) R__x__ - Rectangular shape: specify longer side x shorter sideL__ - ”L” shape: specify side length (equal sides)T__ - ”T” shape: specify side length (equal sides) X__ - Cross shape: specify side length (equal sides)
5 Joiner Type:LJ - Lit joiner, 17 inches nominal side length moduleUJ - Unlit joiner, 2 11/16 inches (68mm) module (0.77kg/1.7 lbs)
6 Direct Lighting:
Output & Color temperature:dRO 27K - 2700K regular output 6W/ftdRO 30K - 3000K regular output 6W/ftdRO 35K - 3500K regular output 6W/ftdRO 40K - 4000K regular output 6W/ftdHO 27K - 2700K high output 12W/ft2 dHO 30K - 3000K high output 12W/ft2
dHO 35K - 3500K high output 12W/ft2
dHO 40K - 4000K high output 12W/ft2
dRO RGB - Tri-color red, green and blue direct lighting 6W/ft3
Optics:NF and WW optics not available for shapes with lit joiner.
WFL - Wide flood, 100° distribution, frosted lens NF - Narrow flood, 30° x 60° distribution, highly reflective white painted
louver4
WW - True asymmetric wallwash, highly reflective white painted louver4
7 Indirect Lighting:
Output & Color temperature:iRO 27K - 2700K regular output 6W/ftiRO 30K - 3000K regular output 6W/ftiRO 35K - 3500K regular output 6W/ftiRO 40K - 4000K regular output 6W/ftiHO 27K - 2700K high output 12W/ft2
iHO 30K - 3000K high output 12W/ft2
iHO 35K - 3500K high output 12W/ft2
iHO 40K - 4000K high output 12W/ft2
iRO RGB - Tri-color red, green and blue indirect lighting 6W/ft3
Optics:WFL - Wide flood, 100° distribution, clear lensBWW - Batwing wide, 170° distribution
8 Control:NO - On/off controlLT - Lumentalk5
DIM - 0-10V dimming option6
DMX/RDM - DMX/RDM enabled7
DALI - DALI dimming option8
ES - Lutron® EcoSystem® Enabled dimming9
9 Mounting:ACC50 - Aircraft cable, 50" (field adjustable)ACC100 - Aircraft cable, 100" (field adjustable)ACC250 - Aircraft cable, 250" (field adjustable)
10 Finish:BK - Black Sandtex10
SI - Silver Sandtex10
WH - Smooth white10
CC - Custom color and finish (please specify RAL color)11
11 Option:BLL - Black painted louver12
SSL - Semi-specular louver12
Photometric performance will vary with black and semi-specular louveroptions, see Photometric Information pages for more information.
LLI2P DI 1 2 3 4 5 6 7 8 9 10 11
Notes:1 347V is not available for 1' [305mm] lengths. 347V is not available for RGB color option or LT control option. 2 High output direct lighting cannot be combined with high output indirect lighting. 3 RGB optionrequires DMX/RDM control to be specified in Control section. 4 Not available for RGB color option and lit joiners. 5 1% minimum dimming value. Available with white light only, not available for 1' [305mm]lengths. 6 10% minimum dimming value. 7 1% minimum dimming value. Fixtures set to by fixture resolution (consult the Resolution Details pages for the number of DMX addresses per fixture length and type).8 1% minimum dimming value. Available with white light only. Consult Typical Wiring Diagram pages for the number of DALI addresses per fixture length and type. 9 1% minimum dimming value. Available withwhite light only, not available for 1' [305mm] lengths. Consult Typical Wiring Diagram pages for the number of EcoSystem® addresses per fixture length and type. 10 Standard white finish for cable and canopy,consult factory for other options. 11 North American RAL colors specified with RAL number only are provided with a smooth/high-gloss finish. Please consult factory for other RAL textures and glosses, or tomatch alternate color charts. Final color matching results may vary. 12 Available for WW and NF optics, not compatible with WFL option.