Test Facilities for SRF Cavity R&D CTF Cryogenic Test Facility – CTF Service building for MDB Three (3) Tevatron satellite refrigerator systems (STAR) Four (4) Mycom compressors Transfer line from CTF to MDB Purifier compressor Purifier skid Meson Detector Blg Meson Detector Building – MDB Purifier skid Storage tanks and buffer Dewars TD MP9 Assembly area & Clean Room Proton Driver and Single-Module test areas SCRF test caves 2 K operation using a vacuum pump capable of 10 g/sec @1.8 K @ + 200 W @ 80 K New Muon Lab - NML High-Brightness Photoinjector and ILC areas AD Cryo Dept. New Muon Lab

Srf Test Facility at Fermilab

Embed Size (px)

Citation preview

Page 1: Srf Test Facility at Fermilab

Test Facilities for SRF Cavity R&DCTF

Cryogenic Test Facility – CTF Service building for MDB• Three (3) Tevatron satellite refrigerator systems (STAR) • Four (4) Mycom compressors• Transfer line from CTF to MDB• Purifier compressor • Purifier skid

Meson Detector Blg

Meson Detector Building – MDB

• Purifier skid• Storage tanks and buffer Dewars TD MP9

Assembly area & Clean Room

Proton Driver and Single-Module test areas● SCRF test caves● 2 K operation using a vacuum pump

capable of 10 g/sec @1.8 K @● + 200 W @ 80 K

New Muon Lab - NMLHigh-Brightness Photoinjector and ILC areas

AD Cryo Dept.New Muon Lab

g g j

Page 2: Srf Test Facility at Fermilab

New Cryogenic Areas and Era – R&D

Fermilab is developing a broad capability to process and test many types of SRF cavities

Technical Division Vertical Test Stand

b ld Meson Detector building Capture Cavity 2 (1.9 GHz) Horizontal Test System (3.9 GHz) Spoke Resonator Test Cryostat

Vertical Test Stand

Horizontal Test Stand

C it t t B “d d” Spoke Resonator Test Cryostat Front end of the HINS (325 MHz)(High Intensity Neutrino Source)

Cavity state Bare “dressed”

Power coupler Axial coupler Side coupler

RF power Low power, High power,

New Muon Lab ILC Front end

RF power CW pulsed

Turnaround ~1 day ~1 week

R i d’êt

Testing cavity

Testing cavity Raison d’être cavity

surface treatment

cavity handling,

accessories

Page 3: Srf Test Facility at Fermilab

ILC SRF

Page 4: Srf Test Facility at Fermilab

Vertical Test Stand @ IB1

Initial operation with single bare 1.3 GHz ILC 9-cell cavities

Baseline: 35 MV/m Q0=10^10Q

Vertical pit

Page 5: Srf Test Facility at Fermilab

ILCTA - MDB Test Stands Layout

HINS R&DHTS

R&DS

Vacuum Pump

CTF

HINSCC2

CTF

Page 6: Srf Test Facility at Fermilab

Cryogenic Test Facility

Three Refrigerator Systems (STAR) Three Heat Exchangers (STAR)

Four Mycom CompressorsDewar+heaterControl Room

Page 7: Srf Test Facility at Fermilab

HINS Transfer Lines – Meson Detector Building

Page 8: Srf Test Facility at Fermilab

Cryogenic Distribution Lines and Vacuum System

Expansion box and bayonet cans Vacuum pump modification

Pi i b VP d A V P b RiPiping between VP and test Areas Vacuum Pump: booster +Ring pump

Page 9: Srf Test Facility at Fermilab

RF for CC2 and HTS

ILC RF controls for four Klystron/Cryostat systems

Both 1.3 and 3.9 GHz; 1ms@10Hz;Fast phase shifter control (100 kHz BW)

Development system in the LLRF test lab

A CW system sometime in the future

Page 10: Srf Test Facility at Fermilab

Capture Cavity 2

Capture Cavity 2 is a high gradient superconducting cavity destined to upgrade the PhotoInjector to 40 MeV.

Measured Peak Gradient: 31 MV/mQo=10^10

Al i d Also permitted to test:- Cryogenic systems- High Level RF power systems- Low Level RF control systems- Klystron & Modulator Interlocks- Piezo-electric Fast Cavity Tuner- Clean Room Facilities

Page 11: Srf Test Facility at Fermilab

Horizontal Test Stand

Horizontal Test Cryostat

C22 – ILC type 2 SRFC22 – ILC type 2 SRF C22 ILC type 2 SRFC22 ILC type 2 SRF

Page 12: Srf Test Facility at Fermilab

HINS Transfer Lines – Meson Detector Building

Page 13: Srf Test Facility at Fermilab

High Intensity Neutrino Source

Front End Layout Cryostat for HINS spoke cavity R&D

=0 22 Cold Mass AssemblySpecification:

cavity R&D

=0.22 Cold Mass Assembly325 MHz45mA

SSR-1 Cryomodule Interconnect

Page 14: Srf Test Facility at Fermilab

Control aspect - EPICS

Page 15: Srf Test Facility at Fermilab

4-Mation via MODULBUS to the APACS Controller

logic bl k dblocks and feedback blocks

Page 16: Srf Test Facility at Fermilab

New Muon Lab (NML)

CC1 CC2RF Gun

CC1 CC2

RF GunCC1

Klystron GalleryLASEREarlier layoutEarlier layout

CC1 CC2

ILC Cryomodules

1 2 & 31,2, & 3

Page 17: Srf Test Facility at Fermilab

Purification System – New Muon Lab