Upload
irene-ramsey
View
83
Download
5
Tags:
Embed Size (px)
DESCRIPTION
Status HV boards. HV boards 1.FIRST ASDBLR HV PROTO BOARD: leakage currents on 100nA CH, humidity at cern. 2. TRIAL 1 Encapsulate caps in Printed Circuit Board 20-80 C schock, Ileak 1nA, (later increase) 3 broken caps Sparking under cap’s Test cycles 10-80C for 2 weeks, - PowerPoint PPT Presentation
Citation preview
HV boards
1.FIRST ASDBLR HV PROTO BOARD: leakage currents on 100nA CH, humidity at cern.
2. TRIAL 1Encapsulate caps in Printed Circuit Board 20-80 C schock, Ileak 1nA, (later increase) 3 broken caps Sparking under cap’s Test cycles 10-80C for 2 weeks,
3. TRIAL 2 improved casting, pick and place paste, no cleaning slurryStill broken capacitors (not HV but mechanical) Curved boards
4. TRIAL 3 Still broken capsNow thermal shocks -40 to +120 CMost probably Rework solder problem
5. TRIAL 4Now better mounting on flat bad, ‘no rework’ , capacitor monitorring
6. If failing “open Boards” with vac casting
Status HV boards
New HV board without fuses
Capacitor monitoring checklist