STOPKIT Test - Ø14” & Ø6” Pipe Spools Set up 14”Ø Pipe 6mm Hole at Plain Pipe 6”Ø Elbow 4mm Hole at Weld Heat Affected Zone Note:- Both pipe spools were Hydro tested at 120 BarG prior to drill to perform the STOPKIT TEST

STOPKIT Test - Ø14” & Ø6” Pipe Spools Set up 14”Ø Pipe 6mm Hole at Plain Pipe6”Ø Elbow 4mm Hole at Weld Heat Affected Zone Note:- Both pipe spools were

Embed Size (px)

Citation preview

Page 1: STOPKIT Test - Ø14” & Ø6” Pipe Spools Set up 14”Ø Pipe 6mm Hole at Plain Pipe6”Ø Elbow 4mm Hole at Weld Heat Affected Zone Note:- Both pipe spools were

STOPKIT Test - Ø14” & Ø6” Pipe Spools Set up

14ӯ Pipe 6mm Hole at Plain Pipe 6ӯ Elbow 4mm Hole at Weld Heat Affected Zone

Note:-

Both pipe spools were Hydro tested at 120 BarG prior to drill to perform the STOPKIT TEST

Page 2: STOPKIT Test - Ø14” & Ø6” Pipe Spools Set up 14”Ø Pipe 6mm Hole at Plain Pipe6”Ø Elbow 4mm Hole at Weld Heat Affected Zone Note:- Both pipe spools were

Arresting an air Leak Under 7.0 BarG Pressure.

Ear protection required due to high noise level.

Leak Arrested at 10 N.m Torque.

STOPKIT Test at 14ӯ Plain Pipe with a 6mm Hole

Note:-

After air test the spool was filled with water and successfully tested at 80 BarG - 20 N.m Torque

Page 3: STOPKIT Test - Ø14” & Ø6” Pipe Spools Set up 14”Ø Pipe 6mm Hole at Plain Pipe6”Ø Elbow 4mm Hole at Weld Heat Affected Zone Note:- Both pipe spools were

Water Leak with Initial Pressure kept at 2.5 BarG. As the leak rate started to be reduced the pressure was gradually increased to 80.0 BarG to assess the STOPKIT performance.

STOPKIT Test 6” Elbow with a 4mm Hole at Weld HAZ

Page 4: STOPKIT Test - Ø14” & Ø6” Pipe Spools Set up 14”Ø Pipe 6mm Hole at Plain Pipe6”Ø Elbow 4mm Hole at Weld Heat Affected Zone Note:- Both pipe spools were

40 N.m Torque Applied Pressure 80.0n BarG

STOPKIT Test 6” Elbow with a 4mm Hole at Weld HAZ

44 N.m Final Torque

Minor Leak - Tear

Leak Permanently Arrested

Page 5: STOPKIT Test - Ø14” & Ø6” Pipe Spools Set up 14”Ø Pipe 6mm Hole at Plain Pipe6”Ø Elbow 4mm Hole at Weld Heat Affected Zone Note:- Both pipe spools were

6” Elbow 14”Ø Pipe80.0 BarG

STOPKIT Final Test at 80.0 BarG - Ø6” Elbow & Ø14” Pipe

Page 6: STOPKIT Test - Ø14” & Ø6” Pipe Spools Set up 14”Ø Pipe 6mm Hole at Plain Pipe6”Ø Elbow 4mm Hole at Weld Heat Affected Zone Note:- Both pipe spools were

STOPKIT 100 – Large Pad for Major Leaks

25mm Hole on Plain Pipe Pressurized up to 36.0 BarG. Evidence of Leak at around 30.0 BarG.

Pressure Stabilized at 25.0 BarG – Leak Stopped

STOPKIT 100

Page 7: STOPKIT Test - Ø14” & Ø6” Pipe Spools Set up 14”Ø Pipe 6mm Hole at Plain Pipe6”Ø Elbow 4mm Hole at Weld Heat Affected Zone Note:- Both pipe spools were

4mm Hole on Top of the Weld - Tested up to 36.0 BarG. No Evidence of Leaks

STOPKIT 50 – Smaller Pad for pinholes

STOPKIT 50