84
Suntec technical Manual

Suntec technical Manual · SUNTEC benefit from more than eighty years of experience of producing fuel units and offer the largest and best selling range of the world

  • Upload
    hakhanh

  • View
    215

  • Download
    1

Embed Size (px)

Citation preview

Suntec technicalManual

Dear Partner,

SUNTEC benefit from more than eighty years of experience of producing fuel units and offer the largest and best selling range of the world.Our commitment is to offer you the best fuel unit in terms of efficiency, reliability and service life.This manual describes the operation and installation of SUNTEC low flow oil pumps. Conversion tables (replacement of models from other pump manufacturers by SUNTEC models), presentation of our Universal AUV pump and a Frequently Asked Question section will give you answers to the questions you face about the maintenance and troubleshooting of your installations. We hope this manual will help you in your daily service.

Your SUNTEC Team

1

TABLE OF CONTENTS

1. Pump working principle ......................................................................................................................... 2

2. SUNTEC pump identification ............................................................................................................. 3

3. Conversion ECKERLE -> SUNTEC ..................................................................................................... 5

4. Conversion DANFOSS -> SUNTEC ................................................................................................ 15

5. Conversion DELTA -> SUNTEC .......................................................................................................... 47

6. Conversion SUNTEC AS, AL, AE -> SUNTEC AUV ........................................................... 53

7. Spare parts and accessories ............................................................................................................. 57

8. Connections ...................................................................................................................................................... 65

9. One-pipe ↔ two-pipe configuration ..................................................................................... 67

10. Pipe Dimensions........................................................................................................................................... 68

11. FAQs.......................................................................................................................................................................... 71

2

1. Pump working principle

1- Oil under suction from tank2- Oil under pressure3- Oil pressure adjustment4- Delivery of oil under pressure to the nozzle5- Solenoid valve controlling cut-off function on nozzle line

Pressure adjustment

Solenoid valve

Shaft seal

Gear set

Return from tank

Inlet from tank

Oil under pressure

To nozzle

Oil under suction

3

5

4

2

1

1

3

2. SUNTEC pump identification2.1 Choice of SUNTEC pump configuration (shaft rotation and nozzle outlet)

Notes :This codification is valid for any SUNTEC pump except A2L pump.In this case, the configuration is determined by the shaft rotation and the side pressure gauge port location.TA, TAR and T pumps exist only in A and C configurations.

A : Pump seen from shaft end, clockwise rotation, right hand nozzle outlet. Example : AL 35 A 9526 6P 0700

B : Pump seen from shaft end, clockwise rotation, left hand nozzle outlet. Example : AN 67 B 1335 6P

C : Pump seen from shaft end, anti-clockwise rotation, left hand nozzle outlet. Example : AS 47 C 1538 6P 0700

D : Pump seen from shaft end, anti-clockwise rotation, right hand nozzle outlet. Example : AE 47 D 1385 6P

2

42

2.2 Marking

Revision number

Revision number

Internal Code

Internal Code

Manufacturing date

Manufacturing datePump type

Pump type and model number

Model number

5

3

3. Conversion ECKERLE -> SUNTEC

ECKERLE Old ref.

ECKERLE New ref. SUNTEC Remarks

UNI 1.2 L5 L14-50 UNI 2.12 L1 L14 AL 35 C 9528 6P 0700AUV 47 L 9857 6P 0700

UNI 1.2 L1 L64-50 UNI 2.12 L1 L64 AL 35 C 9540 4P 0700AUV 47 L 9857 6P 0700

AUV: + Inlet and return connections G1/8-G1/4

UNI 1.2 L5 M14-50 UNI 2.12 L1 M14 AL 35 C 9528 6P 0700AUV 47 L 9857 6P 0700

- UNI 2.12 L1 M64 AL 35 C 9540 4P 0700AUV 47 L 9857 6P 0700

AUV: + Inlet and return connections G1/8-G1/4

UNI 1.2 L5 M64-50-W UNI 2.12 L1 M64-65 AL 35 C 9540 4P 0700AUV 47 L 9857 6P 0700

AUV: + Inlet and return connections G1/8-G1/4

- UNI 2.12 L6 M14 AL 65 C 9589 6P 0700

UNI 1.2 L62 M14-01-W UNI 2.12 L6 M14-65 AL 65 C 9589 6P 0700

UNI 1.72 L62 L14-W UNI 2.17 L6 M14-65 AL 75 CK 9534 5P 0700 Specific model

- UNI 2.2 L5 S74-05 AS 47 D 1550 6P 0700AUV 47 L 9857 6P 0700 AS: G 1/4” Inlet and return

- UNI 2.4 L5 M2 AP 47 C 7556 4P 0700

63

ECKERLE Old ref.

ECKERLE New ref. SUNTEC Remarks

UNI 1.42 L6 A64-W UNI 2.42 L5 L64-65 AT2 45 C 9541 4P 0700

UNI 2.42 R5 R70-ET UNI 2.42 R5 R70 AT2 45 A 9574 4P 0700

UNI 2.1 G22 L1 L10 UNI-E 2.1 G22 AN 47 C 1342 6P AN: Shaft with one flat (1),no top pressure gauge port

UNI 2.1 G41-21 L1 L10 UNI-E 2.1 G41 AN 47 C 1342 6P AN: Shaft with one flat (1)

- UNI-E2.1 G41-13 AE 47 C 1387 6PAUV 47 L 9857 6P 0700

AE: Shaft with one flat (1)AUV: + Kit 991401

- UNI-E 2.1 L1 L10 AN 47 C 1342 6P AN: Shaft with one flat (1)

- UNI-E 2.1 L1 L10-22 AN 47 C 1342 6P AN: Shaft with one flat (1)

UNI 2.1 L1 L44-H1-21 UNI-E 2.1 L1 L10-30 AN 47 C 1342 6P AN: Shaft with one flat (1),no top pressure gauge port

UNI 2.1 L1 L44-21 UNI-E 2.1 L1 L14 AN 47 C 1342 6P

UNI 1.1 L5 L64 -10 UNI-E 2.1 L1 L64 AN 47 C 1342 6P AN: G1/4" Inlet and return

UNI 1.1 L5 L64-M1 UNI-E 2.1 L1 L64-21 AN 47 C 1342 6P AN: G1/4” Inlet and return

UNI 2.1 L5 L40-21 UNI-E 2.1 L5 L10 AN 47 C 1342 6P AN: Shaft with one flat (1)

UNI 2.1 L5 L42-21 UNI-E 2.1 L5 L12 AN 47 C 7228 4P AN: Shaft with one flat (1)

(1) ECKERLE model with 2 flats on the shaft; change coupling.

7

ECKERLE Old ref.

ECKERLE New ref. SUNTEC Remarks

UNI 2.1 L5 L44-21-05 UNI-E 2.1 L5 L14 AN 47 C 1342 6P

- UNI-E 2.1 L5 L14-13 AE 47 C 1387 6PAUV 47 L 9857 6P 0700 AUV: + Kit 991401

UNI 2.1 L5 R44-21 UNI-E 2.1 L5 R14 AN 47 D 1339 6P

- UNI-E 2.1 L5 R14-13 AE 47 D 1385 6PAUV 47 L 9857 6P 0700

UNI 2.1 L5 R94-05 UNI-E 2.1 L5 R74 AN 47 D 1339 6P AN: G1/4" Inlet and return, Pressure range 7 - 14 bars

- UNI-E 2.1 L6 L16-11 AE 67 C 7285 4P

UNI 2.1 L6 L54-05 UNI-E 2.1 L6 L24 AN 67 C 1336 6P AN: Pressure range 7 - 14 bars

UNI 2.1 R1 L40 UNI-E 2.1 R1 L10 AN 47 B 7327 4P AN: Shaft with one flat (1)

UNI 2.1 R1 L44-21 UNI-E 2.1 R1 L14 AN 47 B 7327 4P

UNI 2.1 R5 L42-UI-21 UNI-E 2.1 R5 L12-80 AN 47 BK 7227 4P AN: Shaft with one flat (1)

UNI 2.1 R5 L43-UI-21 UNI-E 2.1 R5 L13-80 AN 47 B 7217 4P AN: Shaft with one flat (1)

UNI 2.1 R5 L44-21 UNI-E 2.1 R5 L14 AN 47 B 7327 4P

UNI 2.1 R5 L54 UNI-E 2.1 R5 L24 AN 47 B 1395 6P

3

8

ECKERLE Old ref.

ECKERLE New ref. SUNTEC Remarks

UNI 2.1 R5 R44-21-05 UNI-E 2.1 R5 R14 AN 47 A 1326 6P

UNI 2.1 R5 R45-21 UNI-E 2.1 R5 R15 AN 47 A 7226 4P

UNI 2.1 R5 R80-05 UNI-E 2.1 R5 R60 AN 47 A 1326 6P AN: Shaft with one flat (1),G1/4" Inlet and return

UNI 2.1 R6 L54-05 UNI-E 2.1 R6 L24 AN 67 B 1335 6P

UNI 2.1 R6 L25 UNI-E 2.1 R6 L25 AN 67 B 7287 4P

- UNI-E 2.2 L1 L10 AS 47 C 1538 6P 0700AUV 47 L 9857 6P 0700 AS: Shaft with one flat (1)

UNI 2.2 L1 L14-21 UNI-E 2.2 L1 L14 AS 47 C 1538 6P 0700AUV 47 L 9857 6P 0700

UNI 2.2 L1 L16-K1-21 UNI-E 2.2 L1 L16-10 AS 47 C 7434 4P 0700AUV 47 L 9857 6P 0700

AUV: + Flange adaptor Ø32-Ø54 (Ref. 3719003)

UNI 2.2 L1 R14-C1-21 UNI-E 2.2 L1 R14-12 AS 47 D 1539 6P 0700AUV 47 L 9857 6P 0700

UNI 2.2 L5 L42 UNI-E 2.2 L5 L12 AS 47 C 7438 4P 0700AUV 47 L 9857 6P 0700

AS: Shaft with one flat (1)AUV: + Hub adaptor Ø32-Ø54 (Ref. 3759833)

(1) ECKERLE model with 2 flats on the shaft; change coupling.3

9

ECKERLE Old ref.

ECKERLE New ref. SUNTEC Remarks

UNI 2.2 L5 L14-21-05 UNI-E 2.2 L5 L14 AS 47 C 1538 6P 0700AUV 47 L 9857 6P 0700

UNI 2.2 L5 L14-Q-21 UNI-E 2.2 L5 L14-92 AS 47 C 1538 6P 0700AUV 47 L 9857 6P 0700

AUV: + Hub adaptor Ø32-Ø54 (Ref. 3759833)

UNI 2.2 L5 L15-21-05 UNI-E 2.2 L5 L15 AS 47 C 7438 4P 0700AUV 47 L 9857 6P 0700

AUV: + Hub adaptor Ø32-Ø54 (Ref. 3759833)

- UNI-E 2.2 L5 L60 AS 47 C 1538 6P 0700AUV 47 L 9857 6P 0700

AS: Shaft with one flat (1), G1/4" Inlet and return

UNI 2.2 L5 M14-C1 UNI-E 2.2 L5 M14-12 AS 47 C 1538 6P 0700AUV 47 L 9857 6P 0700

UNI 2.2 L5 S20-21 UNI-E 2.2 L5 S20 AS 47 D 1557 6P 0700AUV 47 L 9857 6P 0700 AUV: Shaft with one flat (1)

UNI 2.2 L5 S20-21-BUD UNI-E 2.2 L5 S20-BUD AS 47 D 1557 6P 0700AUV 47 L 9857 6P 0700 AUV: Shaft with one flat (1)

- UNI-E 2.2 L5 S74 AS 47 D 1550 6P 0700 AUV 47 L 9857 6P 0700 AS: G 1/4" Inlet and return

- UNI-E 2.2 L6 L14 AS 67 C 1570 6P 0700 AS: Pressure range 10 - 15 bars

3

10

ECKERLE Old ref.

ECKERLE New ref. SUNTEC Remarks

UNI 2.2 L6 L16-K1 UNI-E 2.2 L6 L16-10 AS 67 C 7456 4P 0700 AS: pressure range 10 - 15 bars

UNI 2.2 L6 L24-05 UNI-E 2.2 L6 L24 AS 67 C 1570 6P 0700 AS: pressure range 10 - 15 bars

- UNI-E 2.2 L6 LR14-61 A2L 65 D 9703 4P 0700

- UNI-E 2.2 L7 L26 AL 95 C 9412 4P 0700

- UNI-E 2.2 L7 LR14-61 A2L 95 D 9702 4P 0700

UNI 2.2 R1 L40 UNI-E 2.2 R1 L10 AS 47 B 1537 6P 0700AUV 47 L 9856 6P 0700 AS: Shaft with one flat (1)

UNI 2.2 R1 M14-21-05 UNI-E 2.2 R1 M14 AS 47 B 1537 6P 0700AUV 47 L 9856 6P 0700

UNI 2.2 R1 R24 UNI-E 2.2 R1 R24 AS 47 A 1536 6P 0700AUV 47 L 9856 6P 0700 AS: pressure range 7 - 14 bars

- UNI-E 2.2 R1 S14 AS 47 A 1536 6P 0700AUV 47 L 9856 6P 0700

(1) ECKERLE model with 2 flats on the shaft; change coupling.

3

11

ECKERLE Old ref.

ECKERLE New ref. SUNTEC Remarks

UNI 2.2 R5 L14-21-05 UNI-E 2.2 R5 L14 AS 47 B 1537 6P 0700AUV 47 L 9856 6P 0700

- UNI-E 2.2 R5 M14 AS 47 B 1537 6P 0700AUV 47 L 9856 6P 0700

UNI 2.2 R5 M45 UNI-E 2.2 R5 M15 AS 47 B 1537 6P 0700AUV 47 L 9856 6P 0700 AS: Flange mounting Ø32mm

UNI 2.2 R5 R14-21 UNI-E 2.2 R5 R14 AS 47 A 1536 6P 0700AUV 47 L 9856 6P 0700

UNI 2.2 R5 R60-21 UNI-E 2.2 R5 R60 AS 47 A 1536 6P 0700AUV 47 L 9856 6P 0700

AS: Shaft with one flat (1),G1/4" Inlet and return

- UNI-E 2.2 R5 S14 AS 47 A 1536 6P 0700AUV 47 L 9856 6P 0700

UNI 2.2 R5 S60 UNI-E 2.2 R5 S60 AS 47 A 1536 6P 0700AUV 47 L 9856 6P 0700

AS: Shaft with one flat (1),G1/4" Inlet and return

UNI 2.2 R6 M24-05 UNI-E 2.2 R6 M24 AS 67 B 1575 6P 0700 AS: pressure range 10 - 15 bars

3

12

ECKERLE Old ref.

ECKERLE New ref. SUNTEC Remarks

UNI 2.3 L1 L56-I UNI-E 2.3 L1 L26-80 D 45 C 7389 3PF Specific model

UNI 2.3 L5 L54-S-05 UNI-E 2.3 L5 L24-13 D 45 C 7374 3P

UNI 2.3 L5 L56-I UNI-E 2.3 L5 L26-80 D 45 C 7389 3PF Specific model

- UNI-E 2.3 L5 L64 D 45 C 7374 3P D: G1/4" Inlet and return

UNI 2.3 R5 L54-05 UNI-E 2.3 R5 L24 D 45 B 7347 3P

UNI 2.3 R5 R54-L UNI-E 2.3 R5 R24-93 D 47 A 7383 3P

UNI 2.4 L1 M10-V2 UNI-E 2.4 L1 M10-22 AP 47 C 7556 4P 0700 AP: Shaft with one flat (1)

UNI 2.4 L1 M14-C1 UNI-E 2.4 L1 M14-12 AP 47 C 7556 4P 0700

UNI 2.4 L1 R44 UNI-E 2.4 L1 R14 AP2 45 D 9566 4P 0700

UNI 2.4 L1 R14-C1-21 UNI-E 2.4 L1 R14-12 AP2 45 D 9566 4P 0700

- UNI-E 2.4 L5 L20 AP2 45 C 9569 4P 0700 Specific model

UNI 2.4 L5 L24 UNI-E 2.4 L5 L24 AP 47 C 7556 4P 0700

UNI 2.4 L5 M20-21 UNI-E 2.4 L5 M20 AP2 45 C 9569 4P 0700 Specific model

- UNI-E 2.4 L5 M24 AP 47 C 7556 4P 0700

(1) ECKERLE model with 2 flats on the shaft; change coupling.

3

13

ECKERLE Old ref.

ECKERLE New ref. SUNTEC Remarks

UNI 2.4 L5 S24 UNI-E 2.4 L5 S24 AT2 45 D 9544 4P 0700

UNI 2.4 L6 L24-05 UNI-E 2.4 L6 L24 AP 67 C 7559 4P 0700

UNI 2.4 L6 M24-C1 UNI-E 2.4 L6 M24-12 AP 67 C 7559 4P 0700

- UNI-E 2.4 L7 L22 AP2 95 C 9590 4P 0700 AP2: Flange mounting Ø 32 mm, Shaft with one flat (1)

UNI 2.4 L7 L24-05 UNI-E 2.4 L7 L24 AP2 95 C 9590 4P 0700

UNI 2.4 L7 L56 UNI-E 2.4 L7 L26 AP2 95 C 9590 4P 0700 AP2: Flange mounting Ø 32 mm

- UNI-E 2.4 L7 L26-05 AP2 95 C 9590 4P 0700 AP2: Flange mounting Ø 32 mm

UNI 2.4 L7 M25 UNI-E 2.4 L7 M25 AP2 95 C 9590 4P 0700 AP2: Flange mounting Ø 32 mm

UNI 2.4 R5 L24-05 UNI-E 2.4 R5 L24 AP 47 B 7561 4P 0700

UNI 2.4 R5 R24 UNI-E 2.4 R5 R24 AP 47 A 7555 4P 0700

UNI 2.4 R5 S70-ET UNI-E 2.4 R5 S70 AP 47 A 1593 4P 0700

UNI 2.4 R6 S24-ET UNI-E 2.4 R6 S24 AP 67 A 1594 6P 0700

- UNI-E 2.42 R5 R70 AT2 45 A 9574 4P 0700

- UNI-E 2.6 L5 L14 AN 47 C 1342 6P AN: Pump for two-pipe operation, to be converted to one-pipe operation

3

14

ECKERLE Old ref.

ECKERLE New ref. SUNTEC Remarks

UNI 2.6 L6 L44 UNI-E 2.6 L6 L14 AN 67 C 1336 6P AN: Pump for two-pipe operation, to be converted to one-pipe operation

- UNI-E2.91 L5 L14 AN 47 C 1342 6P + Low pressure kit 991500

UNI 2.91 L7 L44-05 UNI-E 2.91 L7 L14 AE 97 C 7390 2P

UNI 2.96 L5 L44-05 UNI-E 2.96 L5 L14 AN 47 C 1342 6P + Low pressure kit 991500

(1) ECKERLE model with 2 flats on the shaft; change coupling.

3

15

4

4. Conversion DANFOSS -> SUNTEC

DANFOSS SUNTEC Remarks

Left-hand nozzle outlet*

Right-hand nozzle outlet*

BFP 10 L6 071N0272 AE 57C 7373 4P

BFP 10 L6 071N0276 AE 57C 7373 4P DANFOSS: Pump in one-pipe configuration

BFP 10 L8 071N6111 AE 67C 7361 4P

BFP 10 L11 071N6107 AE 77C 7380 2P

BFP 10 L13 071N6103 AE 97C 7390 2P + Kit 991492

BFP 10 R3 071N0177AUV 47 R 9856 6P 0700 + Kit 991401

AN 47B 1395 6P AN 47A 1326 6P

BFP 10 R3 071N0288AUV 47 R 9856 6P 0700 + Kit 991401 DANFOSS: Pump in one-pipe

configurationAN 47B 1395 6P AN 47A 1326 6P

164

DANFOSS SUNTEC Remarks

Left-hand nozzle outlet*

Right-hand nozzle outlet*

BFP 10 R5 071N0166AUV 47 R 9856 6P 0700 + Kit 991401

AN 47B 1395 6P AN 47A 1326 6P

BFP 10 R6 071N0273 AN 57A 7351 4P SUNTEC pump has an hydraulic cut-off,14 bars max.

BFP 10 R6 071N0277 AN 57A 7351 4P

SUNTEC pump has an hydraulic cut-off, 14 bars max.DANFOSS pump in one-pipe configuration

BFP 10 R8 071N6112 AN 67A 7345 4P SUNTEC pump has an hydraulic cut-off

BFP 10 R11 071N6108 AN 77A 7346 2P SUNTEC pump has an hydraulic cut-off

BFP 10 R13 071N6104 AN 97A 7391 2P SUNTEC pump has an hydraulic cut-off

BFP 11 L3 071N0101 AUV 47 L 9857 6P 0700

BFP 11 L3 071N0114

AUV 47 L 9857 6P 0700SUNTEC: Shaft with one flatDANFOSS: Shaft with two flatsAS 47C 1538 6P 0700 AS 47D 1539 6P 0700

AL 35C 9528 6P 0700 AL 35D 9529 6P 0700

*seen from shaft end.

17

DANFOSS SUNTEC Remarks

Left-hand nozzle outlet*

Right-hand nozzle outlet*

BFP 11 L3 071N0141 AUV 47 L 9857 6P 0700 DANFOSS: Pump in one-pipe configuration

BFP 11 L3 071N0142 AUV 47 L 9857 6P 0700 DANFOSS: Pump in one-pipe configuration

BFP 11 L3 071N0144 AUV 47 L 9857 6P 0700

BFP 11 L3 071N0146 AUV 47 L 9857 6P 0700

BFP 11 L3 071N0152 AUV 47 L 9857 6P 0700

BFP 11 L3 071N0153 AUV 47 L 9857 6P 0700 Change Suntec pump coil (new 24V coil ref. 3713823)

BFP 11 L3 071N0184

AUV 47 L 9857 6P 0700

AS 47C 1538 6P 0700 AS 47D 1539 6P 0700

AL 35C 9528 6P 0700 AL 35D 9529 6P 0700

BFP 11 L3 071N0210 AUV 47 L 9857 6P 0700

BFP 11 L3 071N0213 AUV 47 L 9857 6P 0700

4

18

DANFOSS SUNTEC Remarks

Left-hand nozzle outlet*

Right-hand nozzle outlet*

BFP 11 L5 071N0105

AUV 47 L 9857 6P 0700

AS 47C 1538 6P 0700 AS 47D 1539 6P 0700

AL 35C 9528 6P 0700 AL 35D 9529 6P 0700

BFP 11 L5 071N0178

AUV 47 L 9857 6P 0700

AS 47C 1538 6P 0700 AS 47D 1539 6P 0700

AL 35C 9528 6P 0700 AL 35D 9529 6P 0700

BFP 11 L6 071N1270 AS 57C 1583 6P 0700 SUNTEC: 14 bars max.

BFP 11 L6 071N1274 AS 57C 1583 6P 0700SUNTEC: 14 bars max.DANFOSS: Pump in one-pipe configuration

BFP 11 L8 071N6109 AL 65C 9589 6P 0700 SUNTEC: 15 bars max.

BFP 11 R3 071N0143 AUV 47 R 9856 6P 0700

BFP 11 R3 071N0145 AUV 47 R 9856 6P 0700

BFP 11 R3 071N0155 AUV 47 R 9856 6P 0700

*seen from shaft end.

4

19

DANFOSS SUNTEC Remarks

Left-hand nozzle outlet*

Right-hand nozzle outlet*

BFP 11 R3 071N0181 AUV 47 R 9856 6P 0700

BFP 11 R3 071N0183 AUV 47 R 9856 6P 0700

BFP 11 R6 071N0271 AS 57A 7591 4P 0700

BFP 11 R6 071N0275 AS 57A 7591 4P 0700 DANFOSS: Pump in one-pipe configuration

BFP 11 R6 071N1271 AS 57A 7591 4P 0700 SUNTEC: 14 bars max.

BFP 11 R6 071N1275 AS 57A 7591 4P 0700SUNTEC: 14 bars max.DANFOSS: Pump in one-pipe configuration

BFP 11 R8 071N6110 AL 65B 9532 6P 0700

BFP 11 R11 071N6106 AL 75B 9539 6P 0700SUNTEC: 15 bars max. and left nozzle outletDANFOSS: Right nozzle outlet

BFP 12 L6 071N6217 A2L 65 CK 9704 4P 0700

BFP 12 L8 071N6210 A2L 65 CK 9704 4P 0700

4

20

DANFOSS SUNTEC Remarks

Left-hand nozzle outlet*

Right-hand nozzle outlet*

BFP 12 L11 071N6202 A2L 75 CK 9701 4P 0700

BFP 12 L13 071N6203 A2L 95 D 9702 4P 0700 SUNTEC: Right nozzle outletDANFOSS: Left nozzle outlet

BFP 12 R6 071N6218 A2L 65 A 9708 4P 0700

BFP 12 R8 071N6219 A2L 65 A 9708 4P 0700

BFP 12 R11 071N6214 A2L 95 B 9711 4P 0700 SUNTEC: Right nozzle outletDANFOSS: Left nozzle outlet

BFP 12 R13 071N6220 A2L 95 B 9711 4P 0700

BFP 20 L3 071N0108AUV 47 L 9857 6P 0700 + Kit 991401

AN 47 C 1342 6P AN 47 D 1339 6P

BFP 20 L3 071N0125AUV 47 L 9857 6P 0700 + Kit 991401

AN 47 C 1342 6P AN 47 D 1339 6P

*seen from shaft end.4

21

DANFOSS SUNTEC Remarks

Left-hand nozzle outlet*

Right-hand nozzle outlet*

BFP 20 L3 071N0127AUV 47 L 9857 6P 0700 + Kit 991401

AN 47C 1342 6P AN 47D 1339 6P

BFP 20 L3 071N0161AUV 47 L 9857 6P 0700 + Kit 991401

AN 47C 1342 6P AN 47D 1339 6P

BFP 20 L3 071N0168AUV 47 L 9857 6P 0700 + Kit 991401

AN 47C 1342 6P AN 47D 1339 6P

BFP 20 L3 071N0212AUV 47 L 9857 6P 0700 + Kit 991401

SUNTEC: Shaft with one flatDANFOSS: Shaft with two flats

AN 47C 1342 6P AN 47D 1339 6P

BFP 20 L3 071N0267AUV 47 L 9857 6P 0700 + Kit 991401

AN 47C 1342 6P AN 47D 1339 6P

4

22

DANFOSS SUNTEC Remarks

Left-hand nozzle outlet*

Right-hand nozzle outlet*

BFP 20 L3 071N0295

AUV 47 L 9857 6P 0700

AS 47C 1538 6P 0700 AS 47D 1539 6P 0700

AL 35C 9528 6P 0700 AL 35D 9529 6P 0700

BFP 20 L5 071N0126AUV 47 L 9857 6P 0700 + Kit 991401

AN 47C 1342 6P AN 47D 1339 6P

BFP 20 R3 071N0118AUV 47 R 9856 6P 0700 + Kit 991401

AN 47B 1395 6P AN 47A 1326 6P

BFP 20 R3 071N0128AUV 47 R 9856 6P 0700 + Kit 991401

AN 47B 1395 6P AN 47A 1326 6P

BFP 20 R3 071N0162AUV 47 R 9856 6P 0700 + Kit 991401

AN 47B 1395 6P AN 47A 1326 6P

*seen from shaft end.

4

23

DANFOSS SUNTEC Remarks

Left-hand nozzle outlet*

Right-hand nozzle outlet*

BFP 20 R3 071N0169AUV 47 R 9856 6P 0700 + Kit 991401

AN 47B 1395 6P AN 47A 1326 6P

BFP 20 R3 071N0229AUV 47 R 9856 6P 0700 + Kit 991401

AN 47B 1395 6P AN 47A 1326 6P

BFP 20 R3 071N0298AUV 47 R 9856 6P 0700 + Kit 991401

DANFOSS: Pump in one-pipe configuration

AN 47B 1395 6P AN 47A 1326 6P

BFP 20 R5 071N0129AUV 47 R 9856 6P 0700 + Kit 991401

AN 47B 1395 6P AN 47A 1326 6P

BFP 20 R5 071N0180AUV 47 R 9856 6P 0700 + Kit 991401

AN 47B 1395 6P AN 47A 1326 6P

4

24

DANFOSS SUNTEC Remarks

Left-hand nozzle outlet*

Right-hand nozzle outlet*

BFP 21 L2 071N2123

AUV 47 L 9857 6P 0700

AS 47C 1538 6P 0700 AL 35D 9529 6P 0700

AL 35C 9528 6P 0700 AS 47D 1539 6P 0700

BFP 21 L3 071N0102

AUV 47 L 9857 6P 0700

AS 47C 1538 6P 0700 AS 47D 1539 6P 0700

AL 35C 9528 6P 0700 AL 35D 9529 6P 0700

BFP 21 L3 071N0103

AUV 47 L 9857 6P 0700

AS 47C 1538 6P 0700 AS 47D 1539 6P 0700

AL 35C 9528 6P 0700 AL 35D 9529 6P 0700

BFP 21 L3 071N0104

AUV 47 L 9857 6P 0700

AS 47C 1538 6P 0700 AS 47D 1539 6P 0700

AL 35C 9528 6P 0700 AL 35D 9529 6P 0700

*seen from shaft end.

4

25

DANFOSS SUNTEC Remarks

Left-hand nozzle outlet*

Right-hand nozzle outlet*

BFP 21 L3 071N0111

AUV 47 L 9857 6P 0700

AS 47C 1538 6P 0700 AS 47D 1539 6P 0700

AL 35C 9528 6P 0700 AL 35D 9529 6P 0700

BFP 21 L3 071N0113

AUV 47 L 9857 6P 0700

AS 47C 1538 6P 0700 AS 47D 1539 6P 0700

AL 35C 9528 6P 0700 AL 35D 9529 6P 0700

BFP 21 L3 071N0119

AUV 47 L 9857 6P 0700

AS 47C 1538 6P 0700 AS 47D 1539 6P 0700

AL 35C 9528 6P 0700 AL 35D 9529 6P 0700

BFP 21 L3 071N0122

AUV 47 L 9857 6P 0700

AS 47C 1538 6P 0700 AS 47D 1539 6P 0700

AL 35C 9528 6P 0700 AL 35D 9529 6P 0700

4

26

DANFOSS SUNTEC Remarks

Left-hand nozzle outlet*

Right-hand nozzle outlet*

BFP 21 L3 071N0123

AUV 47 L 9857 6P 0700Change Suntec pump coil (new 110V coil ref. 3713824)AS 47C 1538 6P 0700 AS 47D 1539 6P 0700

AL 35C 9528 6P 0700 AL 35D 9529 6P 0700

BFP 21 L3 071N0130

AUV 47 L 9857 6P 0700

AS 47C 1538 6P 0700 AS 47D 1539 6P 0700

AL 35C 9528 6P 0700 AL 35D 9529 6P 0700

BFP 21 L3 071N0132

AUV 47 L 9857 6P 0700

AS 47C 1538 6P 0700 AS 47D 1539 6P 0700

AL 35C 9528 6P 0700 AL 35D 9529 6P 0700

BFP 21 L3 071N0147

AUV 47 L 9857 6P 0700

AS 47C 1538 6P 0700 AS 47D 1539 6P 0700

AL 35C 9528 6P 0700 AL 35D 9529 6P 0700

*seen from shaft end.

4

27

DANFOSS SUNTEC Remarks

Left-hand nozzle outlet*

Right-hand nozzle outlet*

BFP 21 L3 071N0148

AUV 47 L 9857 6P 0700

AS 47C 1538 6P 0700 AS 47D 1539 6P 0700

AL 35C 9528 6P 0700 AL 35D 9529 6P 0700

BFP 21 L3 071N0150

AUV 47 L 9857 6P 0700

AS 47C 1538 6P 0700 AS 47D 1539 6P 0700

AL 35C 9528 6P 0700 AL 35D 9529 6P 0700

BFP 21 L3 071N0151

AUV 47 L 9857 6P 0700

AS 47C 1538 6P 0700 AS 47D 1539 6P 0700

AL 35C 9528 6P 0700 AL 35D 9529 6P 0700

BFP 21 L3 071N0156

AUV 47 L 9857 6P 0700DANFOSS: Pump in one-pipe configurationAS 47C 1538 6P 0700 AS 47D 1539 6P 0700

AL 35C 9528 6P 0700 AL 35D 9529 6P 0700

4

28

DANFOSS SUNTEC Remarks

Left-hand nozzle outlet*

Right-hand nozzle outlet*

BFP 21 L3 071N0164

AUV 47 L 9857 6P 0700

AS 47C 1538 6P 0700 AS 47D 1539 6P 0700

AL 35C 9528 6P 0700 AL 35D 9529 6P 0700

BFP 21 L3 071N0170

AUV 47 L 9857 6P 0700

AS 47C 1538 6P 0700 AS 47D 1539 6P 0700

AL 35C 9528 6P 0700 AL 35D 9529 6P 0700

BFP 21 L3 071N0175

AUV 47 L 9857 6P 0700

AS 47C 1538 6P 0700 AS 47D 1539 6P 0700

AL 35C 9528 6P 0700 AL 35D 9529 6P 0700

BFP 21 L3 071N0176

AUV 47 L 9857 6P 0700Change Suntec pump coil(new 110V coil ref. 3713824)AS 47C 1538 6P 0700 AS 47D 1539 6P 0700

AL 35C 9528 6P 0700 AL 35D 9529 6P 0700

*seen from shaft end.

4

29

DANFOSS SUNTEC Remarks

Left-hand nozzle outlet*

Right-hand nozzle outlet*

BFP 21 L3 071N0179

AUV 47 L 9857 6P 0700

AS 47C 1538 6P 0700 AS 47D 1539 6P 0700

AL 35C 9528 6P 0700 AL 35D 9529 6P 0700

BFP 21 L3 071N0182

AUV 47 L 9857 6P 0700

AS 47C 1538 6P 0700 AS 47D 1539 6P 0700

AL 35C 9528 6P 0700 AL 35D 9529 6P 0700

BFP 21 L3 071N0185

AUV 47 L 9857 6P 0700

AS 47C 1538 6P 0700 AS 47D 1539 6P 0700

AL 35C 9528 6P 0700 AL 35D 9529 6P 0700

BFP 21 L3 071N0189

AUV 47 L 9857 6P 0700Change Suntec pump coil(new 24V coil ref. 3713823)AS 47C 1538 6P 0700 AS 47D 1539 6P 0700

AL 35C 9528 6P 0700 AL 35D 9529 6P 0700

4

30

DANFOSS SUNTEC Remarks

Left-hand nozzle outlet*

Right-hand nozzle outlet*

BFP 21 L3 071N0193

AUV 47 L 9857 6P 0700

AS 47C 1538 6P 0700 AS 47D 1539 6P 0700

AL 35C 9528 6P 0700 AL 35D 9529 6P 0700

BFP 21 L3 071N0197

AUV 47 L 9857 6P 0700

AS 47C 1538 6P 0700 AS 47D 1539 6P 0700

AL 35C 9528 6P 0700 AL 35D 9529 6P 0700

BFP 21 L3 071N0204

AUV 47 L 9857 6P 0700

AS 47C 1538 6P 0700 AS 47D 1539 6P 0700

AL 35C 9528 6P 0700 AL 35D 9529 6P 0700

BFP 21 L3 071N0209

AUV 47 L 9857 6P 0700

AS 47C 1538 6P 0700 AS 47D 1539 6P 0700

AL 35C 9528 6P 0700 AL 35D 9529 6P 0700

*seen from shaft end.4

31

DANFOSS SUNTEC Remarks

Left-hand nozzle outlet*

Right-hand nozzle outlet*

BFP 21 L3 071N0217

AUV 47 L 9857 6P 0700

AS 47C 1538 6P 0700 AS 47D 1539 6P 0700

AL 35C 9528 6P 0700 AL 35D 9529 6P 0700

BFP 21 L3 071N0226

AUV 47 L 9857 6P 0700

AS 47C 1538 6P 0700 AS 47D 1539 6P 0700

AL 35C 9528 6P 0700 AL 35D 9529 6P 0700

BFP 21 L3 071N0228

AUV 47 L 9857 6P 0700

AS 47C 1538 6P 0700 AS 47D 1539 6P 0700

AL 35C 9528 6P 0700 AL 35D 9529 6P 0700

BFP 21 L3 071N1214

AUV 47 L 9857 6P 0700DANFOSS: Pump in one-pipe configurationAS 47C 1538 6P 0700 AS 47D 1539 6P 0700

AL 35C 9528 6P 0700 AL 35D 9529 6P 0700

4

32

DANFOSS SUNTEC Remarks

Left-hand nozzle outlet*

Right-hand nozzle outlet*

BFP 21 L3 071N1217

AUV 47 L 9857 6P 0700

AS 47C 1538 6P 0700 AS 47D 1539 6P 0700

AL 35C 9528 6P 0700 AL 35D 9529 6P 0700

BFP 21 L3 071N1219

AUV 47 L 9857 6P 0700

AS 47C 1538 6P 0700 AS 47D 1539 6P 0700

AL 35C 9528 6P 0700 AL 35D 9529 6P 0700

BFP 21 L3 LE 071N2103 ALE 35C 9324 6P 0700

BFP 21 L3 LE 071N2104 ALE 35C 9324 6P 0700

BFP 21 L3 LE 071N2108 ALE 35C 9324 6P 0700

BFP 21 L3 LE 071N2110 ALE V35D 9337 6P 0700

BFP 21 L3 LE 071N2112 ALE 35C 9324 6P 0700

BFP 21 L3 LE 071N2113 ALE 35C 9324 6P 0700

*seen from shaft end.

4

33

DANFOSS SUNTEC Remarks

Left-hand nozzle outlet*

Right-hand nozzle outlet*

BFP 21 L3 LE 071N2114 ALE 35C 9324 6P 0700

BFP 21 L3 LE 071N2118 ALE V35D 9337 6P 0700

BFP 21 L3 LE 071N2119 ALE 35C 9324 6P 0700

BFP 21 L3 LE 071N4105 ALE V35D 9337 6P 0700

BFP 21 L3-LE-S 071N0233 ALE 35C 9324 6P 0700 SUNTEC: Shaft with one flatDANFOSS: Shaft with two flats

BFP 21 L3-LE-S 071N0264 ALE 35C 9324 6P 0700

BFP 21 L3-LE-S 071N2116 ALE 35C 9324 6P 0700

BFP 21 L3-LE-S 071N2125 ALE 35C 9324 6P 0700

BFP 21 L3-LE-S 071N2225 ALE 35C 9324 6P 0700

BFP 21 L3-LE-S 071N2303 ALE 35C 9324 6P 0700 SUNTEC: Shaft with one flatDANFOSS: Shaft with two flats

4

34

DANFOSS SUNTEC Remarks

Left-hand nozzle outlet*

Right-hand nozzle outlet*

BFP 21 L5 071N0107

AUV 47 L 9857 6P 0700

AS 47C 1538 6P 0700 AS 47D 1539 6P 0700

AL 35C 9528 6P 0700 AL 35D 9529 6P 0700

BFP 21 L5 071N0116

AUV 47 L 9857 6P 0700

AS 47C 1538 6P 0700 AS 47D 1539 6P 0700

AL 35C 9528 6P 0700 AL 35D 9529 6P 0700

BFP 21 L5 071N0158

AUV 47 L 9857 6P 0700

AS 47C 1538 6P 0700 AS 47D 1539 6P 0700

AL 35C 9528 6P 0700 AL 35D 9529 6P 0700

BFP 21 L5 071N0172

AUV 47 L 9857 6P 0700

AS 47C 1538 6P 0700 AS 47D 1539 6P 0700

AL 35C 9528 6P 0700 AL 35D 9529 6P 0700

*seen from shaft end.4

35

DANFOSS SUNTEC Remarks

Left-hand nozzle outlet*

Right-hand nozzle outlet*

BFP 21 L5 071N0194

AUV 47 L 9857 6P 0700

AS 47C 1538 6P 0700 AS 47D 1539 6P 0700

AL 35C 9528 6P 0700 AL 35D 9529 6P 0700

BFP 21 L5 071N0202

AUV 47 L 9857 6P 0700

AS 47C 1538 6P 0700 AS 47D 1539 6P 0700

AL 35C 9528 6P 0700 AL 35D 9529 6P 0700

BFP 21 L5 071N0227

AUV 47 L 9857 6P 0700

AS 47C 1538 6P 0700 AS 47D 1539 6P 0700

AL 35C 9528 6P 0700 AL 35D 9529 6P 0700

BFP 21 L5 071N0292

AUV 47 L 9857 6P 0700

AS 47C 1538 6P 0700 AS 47D 1539 6P 0700

AL 35C 9528 6P 0700 AL 35D 9529 6P 0700

4

36

DANFOSS SUNTEC Remarks

Left-hand nozzle outlet*

Right-hand nozzle outlet*

BFP 21 R3 071N0109

AUV 47 R 9856 6P 0700

AS 47B 1537 6P 0700AS 47A 1536 6P 0700

AL 35A 9526 6P 0700

BFP 21 R3 071N0112

AUV 47 R 9856 6P 0700

AS 47B 1537 6P 0700AS 47A 1536 6P 0700

AL 35A 9526 6P 0700

BFP 21 R3 071N0136

AUV 47 R 9856 6P 0700

AS 47B 1537 6P 0700AS 47A 1536 6P 0700

AL 35A 9526 6P 0700

BFP 21 R3 071N0154

AUV 47 R 9856 6P 0700

AS 47B 1537 6P 0700AS 47A 1536 6P 0700

AL 35A 9526 6P 0700

*seen from shaft end.4

37

DANFOSS SUNTEC Remarks

Left-hand nozzle outlet*

Right-hand nozzle outlet*

BFP 21 R3 071N0157

AUV 47 R 9856 6P 0700DANFOSS: Pump in one-pipe configuration

AS 47B 1537 6P 0700AS 47A 1536 6P 0700

AL 35A 9526 6P 0700

BFP 21 R3 071N0167

AUV 47 R 9856 6P 0700

AS 47B 1537 6P 0700AS 47A 1536 6P 0700

AL 35A 9526 6P 0700

BFP 21 R3 071N0171

AUV 47 R 9856 6P 0700

AS 47B 1537 6P 0700AS 47A 1536 6P 0700

AL 35A 9526 6P 0700

BFP 21 R3 071N0198

AUV 47 R 9856 6P 0700

AS 47B 1537 6P 0700

AS 47A 1536 6P 0700

AL 35A 9526 6P 0700

4

38

DANFOSS SUNTEC Remarks

Left-hand nozzle outlet*

Right-hand nozzle outlet*

BFP 21 R3 071N0208

AUV 47 R 9856 6P 0700

AS 47B 1537 6P 0700

AS 47A 1536 6P 0700

AL 35A 9526 6P 0700

BFP 21 R3 071N0214

AUV 47 R 9856 6P 0700

AS 47B 1537 6P 0700AS 47A 1536 6P 0700

AL 35A 9526 6P 0700

BFP 21 R3 071N0215

AUV 47 R 9856 6P 0700

AS 47B 1537 6P 0700AS 47A 1536 6P 0700

AL 35A 9526 6P 0700

BFP 21 R3 071N0231

AUV 47 R 9856 6P 0700DANFOSS: Pump in one-pipe configuration

AS 47B 1537 6P 0700AS 47A 1536 6P 0700

AL 35A 9526 6P 0700

*seen from shaft end.4

39

DANFOSS SUNTEC Remarks

Left-hand nozzle outlet*

Right-hand nozzle outlet*

BFP 21 R3 071N1215

AUV 47 R 9856 6P 0700DANFOSS: Pump in one-pipe configuration

AS 47B 1537 6P 0700AS 47A 1536 6P 0700

AL 35A 9526 6P 0700

BFP 21 R5 071N0120

AUV 47 R 9856 6P 0700

AS 47B 1537 6P 0700AS 47A 1536 6P 0700

AL 35A 9526 6P 0700

BFP 21 R5 071N0159

AUV 47 R 9856 6P 0700

AS 47B 1537 6P 0700AS 47A 1536 6P 0700

AL 35A 9526 6P 0700

BFP 21 R5 071N0163

AUV 47 R 9856 6P 0700

AS 47B 1537 6P 0700

AS 47A 1536 6P 0700

AL 35A 9526 6P 0700

4

40

DANFOSS SUNTEC Remarks

Left-hand nozzle outlet*

Right-hand nozzle outlet*

BFP 21 R5 071N0165

AUV 47 R 9856 6P 0700

AS 47B 1537 6P 0700AS 47A 1536 6P 0700

AL 35A 9526 6P 0700

BFP 21 R5 071N0173

AUV 47 R 9856 6P 0700

AS 47B 1537 6P 0700AS 47A 1536 6P 0700

AL 35A 9526 6P 0700

BFP 21 R5 071N0195

AUV 47 R 9856 6P 0700

AS 47B 1537 6P 0700AS 47A 1536 6P 0700

AL 35A 9526 6P 0700

BFP 21 R5 071N0207

AUV 47 R 9856 6P 0700

AS 47B 1537 6P 0700AS 47A 1536 6P 0700

AL 35A 9526 6P 0700

*seen from shaft end.4

41

DANFOSS SUNTEC Remarks

Left-hand nozzle outlet*

Right-hand nozzle outlet*

BFP 31 L3 071N0115

AUV 47 L 9857 6P 0700

AS 47C 1538 6P 0700 AS 47D 1539 6P 0700

AL 35C 9528 6P 0700 AL 35D 9529 6P 0700

BFP 31 L3 071N0133

AUV 47 L 9857 6P 0700DANFOSS: Pump in one-pipe configurationAS 47C 1538 6P 0700 AS 47D 1539 6P 0700

AL 35C 9528 6P 0700 AL 35D 9529 6P 0700

BFP 31 L3 071N0149

AUV 47 L 9857 6P 0700

AS 47C 1538 6P 0700 AS 47D 1539 6P 0700

AL 35C 9528 6P 0700 AL 35D 9529 6P 0700

BFP 31 L3 071N0190

AUV 47 L 9857 6P 0700

AS 47C 1538 6P 0700 AS 47D 1539 6P 0700

AL 35C 9528 6P 0700 AL 35D 9529 6P 0700

4

42

DANFOSS SUNTEC Remarks

Left-hand nozzle outlet*

Right-hand nozzle outlet*

BFP 31 L3 071N0191

AUV 47 L 9857 6P 0700

AS 47C 1538 6P 0700 AS 47D 1539 6P 0700

AL 35C 9528 6P 0700 AL 35D 9529 6P 0700

BFP 31 L3 071N0192

AUV 47 L 9857 6P 0700

AS 47C 1538 6P 0700 AS 47D 1539 6P 0700

AL 35C 9528 6P 0700 AL 35D 9529 6P 0700

BFP 31 L3 071N1201

AUV 47 L 9857 6P 0700

AS 47C 1538 6P 0700 AS 47D 1539 6P 0700

AL 35C 9528 6P 0700 AL 35D 9529 6P 0700

BFP 31 L3 071N1203

AUV 47 L 9857 6P 0700

AS 47C 1538 6P 0700 AS 47D 1539 6P 0700

AL 35C 9528 6P 0700 AL 35D 9529 6P 0700

BFP 31 L3 LE 071N2109 ALE 35C 9324 6P 0700

BFP 41 L3 071N0135 AUV 47 L 9857 6P 0700

*seen from shaft end.

4

43

DANFOSS SUNTEC Remarks

Left-hand nozzle outlet*

Right-hand nozzle outlet*

BFP 41 L3 071N0160 AUV 47 L 9857 6P 0700 SUNTEC: Coil on the topDANFOSS: Coil at one side of the body

BFP 41 L3 071N0174 AUV 47 L 9857 6P 0700

BFP 41 L3 071N0188 AUV 47 L 9857 6P 0700

BFP 41 L3 071N0224 AUV 47 L 9857 6P 0700

BFP 41 L3 071N0225 AUV 47 L 9857 6P 0700

BFP 41 L3 071N1213 AUV 47 L 9857 6P 0700

BFP 41 R3 071N0137/138 AUV 47 R 9856 6P 0700 SUNTEC: Coil on the topDANFOSS: Coil at one side of the body

BFP 41 R3 071N0196 AUV 47 R 9856 6P 0700

BFP 41 R3 071N0235 AUV 47 R 9856 6P 0700

BFP 51 L6 071N6204 AP2 65C 9511 4P 0700

4

44

DANFOSS SUNTEC Remarks

Left-hand nozzle outlet*

Right-hand nozzle outlet*

BFP 51 L8 071N6222 AP2 65C 9511 4P 0700

BFP 51 L11 071N6205 AP2 95C 9590 2P 0700

BFP 51 L13 071N6225 AP2 95C 9590 2P 0700

BFP 51 R6 071N6221 AP2 65B 9523 4P 0700

BFP 51 R8 071N6223 AP2 65B 9523 4P 0700

BFP 52 L6 071N6206 AT2 55C 9549 4P 0700

BFP 52 L8 071N6207 AT2 65C 9556 4P 0700

BFP 52 L11 071N6209 AT2 75C 9583 4P 0700

BFP 52 L13 071N6211 AT2 95C 9585 4P 0700

BFP 52 R6 071N6227 AT2 55B 9515 4P 0700

BFP 52 R8 071N6208 AT2 65B 9587 4P 0700

*seen from shaft end.4

45

DANFOSS SUNTEC Remarks

Left-hand nozzle outlet*

Right-hand nozzle outlet*

BFP 52 R11 071N6210 AT2 75B 9591 4P 0700

BFP 52 R13 071N6212 AT2 95B 9592 4P 0700

BFP 52E L3 071N2201 ATE2 V45 C 9305 6P 0700

BFP 52E L3 071N2209 ATE2 V45 C 9305 6P 0700

BFP 52E L3 071N2211 ATE2 V45 C 9305 6P 0700 SUNTEC: Shaft with one flatDANFOSS: Shaft with two flats

BFP 52E L3 071N2213 ATE2 V45 C 9305 6P 0700

BFP 52E L3 071N2264 ATE2 V45 C 9305 6P 0700

BFP 52E L5 071N2202 ATE2 V45 C 9305 6P 0700

BFP 52E L5 071N2205 ATE2 V45 C 9305 6P 0700

BFP 52E L5 071N2212 ATE2 V45 C 9305 6P 0700

4

46

DANFOSS SUNTEC Remarks

Left-hand nozzle outlet*

Right-hand nozzle outlet*

BFP 52E L5 071N2217 ATE2 V45 C 9305 6P 0700

BFP 52E L5 071N2220 ATE2 V45 C 9305 6P 0700

BFP 52E L5 071N2265 ATE2 V45 C 9305 6P 0700

BFP 52E R3 071N2203 AT2 55B 9515 4P 0700

BFP 52E R5 071N2204 AT2 55B 9515 4P 0700

BFP 53 L6 071N6213 AT3 55C 9550 4P 0700

BFP 53 L8 071N6229 AT3 65C 9561 4P 0700

*seen from shaft end.

4

47

5

5. Conversion DELTA -> SUNTEC

DELTA SUNTEC Remarks

V-, VM- Type A-, AD- Type

V1LR2 - AN 47C 1342 6P

V1LR1 - AN 47C 1342 6P Delta : Pump in one-pipe configuration

V1LL2 - AN 47D 1339 6P

V1LL1 - AN 47D 1339 6P Delta : Pump in one-pipe configuration

V1RL2 - AN 47A 1326 6P

V1RL1 - AN 47A 1326 6P Delta : Pump in one-pipe configuration

V1RR2 - AN 47B 1395 6P

V1RR1 - AN 47B 1395 6P Delta : Pump in one-pipe configuration

485

DELTA SUNTEC Remarks

V-, VM- Type A-, AD- Type

V2LR2 - AN 57C 7349 4P

V2LR1 - AN 57C 7349 4P Delta : Pump in one-pipe configuration

V2LL2 - AN 57D 1303 6P

V2LL1 - AN 57D 1303 6P Delta : Pump in one-pipe configuration

V2RL2 - AN 57A 7351 4P

V2RL1 - AN 57A 7351 4P Delta : Pump in one-pipe configuration

V2RR2 - AN 57B 1330 6P

V2RR1 - AN 57B 1330 6P Delta : Pump in one-pipe configuration

49

DELTA SUNTEC Remarks

V-, VM- Type A-, AD- Type

VD1LR2 AD1-L2 AN 47C 1342 6P

VD1LR1 AD1-L1 AN 47C 1342 6P Delta : Pump in one-pipe configuration

VD1LL2 AD1-L2 AN 47D 1339 6P

VD1LL1 AD1-L1 AN 47D 1339 6P Delta : Pump in one-pipe configuration

VD1RL2 AD1-R2 AN 47A 1326 6P

VD1RL1 AD1-R1 AN 47A 1326 6P Delta : Pump in one-pipe configuration

VD1RR2 AD1-R2 AN 47B 1395 6P

VD1RR1 AD1-R1 AN 47B 1395 6P Delta : Pump in one-pipe configuration

5

50

DELTA SUNTEC Remarks

V-, VM- Type A-, AD- Type

VD2LR2 AD2-L2 AN 57C 7349 4P

VD2LR1 AD2-L1 AN 57C 7349 4P Delta : Pump in one-pipe configuration

VD2LL2 AD2-L2 AN 57D 1303 6P

VD2RL2 AD2-R2 AN 57A 7351 4P

VD2RL1 AD2-R1 AN 57A 7351 4P Delta : Pump in one-pipe configuration

VD2RR2 AD2-R2 AN 57B 1330 6P

VD2RR1 AD2-R1 AN 57B 1330 6P Delta : Pump in one-pipe configuration

5

51

DELTA SUNTEC Remarks

V-, VM- Type A-, AD- Type

VM1LR2 A1-L2 AUV 47 L 9857 6P 0700

VM1LR1 A1-L1 AUV 47 L 9857 6P 0700 Delta : Pump in one-pipe configuration

VM1LL2 A1-L2 AUV 47 L 9857 6P 0700

VM1LL1 A1-L1 AUV 47 L 9857 6P 0700 Delta : Pump in one-pipe configuration

VM1RL2 A1-R2 AUV 47 R 9856 6P 0700

VM1RL1 A1-R1 AUV 47 R 9856 6P 0700 Delta : Pump in one-pipe configuration

VM1RR2 A1-R2 AUV 47 R 9856 6P 0700

VM1RR1 A1-R1 AUV 47 R 9856 6P 0700 Delta : Pump in one-pipe configuration

5

52

DELTA SUNTEC Remarks

V-, VM- Type A-, AD- Type

VM2LR2 A2-L2 AUV 47 L 9857 6P 0700

VM2LR1 A2-L1 AUV 47 L 9857 6P 0700 Delta : Pump in one-pipe configuration

VM2LL2 A2-L2 AUV 47 L 9857 6P 0700

VM2LL1 A2-L1 AUV 47 L 9857 6P 0700 Delta : Pump in one-pipe configuration

VM2RL2 A2-R2 AUV 47 R 9856 6P 0700

VM2RL1 A2-R1 AUV 47 R 9856 6P 0700 Delta : Pump in one-pipe configuration

VM2RR2 A2-R2 AUV 47 R 9856 6P 0700

VM2RR1 A2-R1 AUV 47 R 9856 6P 0700 Delta : Pump in one-pipe configuration

5

53

6

6. Conversion SUNTEC AS, AL, AE -> SUNTEC AUV

AS AUV Remarks

AS 47 A 1536 xP 0500/0700 AUV 47 R 9856 6P 0700

AS 47 A 1564 xP 0500/0700 AUV 47 R 9856 6P 0700

AS 47 A 1589 xP 0500/0700 AUV 47 R 9856 6P 0700

AS 47 A 1602 xP 0500/0700 AUV 47 R 9856 6P 0700

AS 47 A 7432 xP 0500/0700 AUV 47 R 9856 6P 0700 + Flange adaptor Ø32-Ø54 (Ref. 3719003)

AS 47 A 7436 xP 0500/0700 AUV 47 R 9856 6P 0700 + Hub adaptor Ø32-Ø54 (Ref. 3759833)

AS V 47 A 1636 xP 0500/0700 AUV 47 R 9856 6P 0700

AS 47 B 1537 xP 0500/0700 AUV 47 R 9856 6P 0700

AS 47 BK 1551 xP 0500/0700 AUV 47 R 9856 6P 0700

AS 47 B 7445 xP 0500/0700 AUV 47 R 9856 6P 0700

AS 47 C 1538 xP 0500/0700 AUV 47 L 9857 6P 0700

AS 47 CK 1554 xP 0500/0700 AUV 47 L 9857 6P 0700

AS 47 C 1569 xP 0500/0700 AUV 47 L 9857 6P 0700

AS 47 C 1578 xP 0500/0700 AUV 47 L 9857 6P 0700

AS 47 CK 1582 xP 0500/0700 AUV 47 L 9857 6P 0700

546

AS AUV Remarks

AS 47 C 1603 xP 0500/0700 AUV 47 L 9857 6P 0700

AS 47 C 1604 xP 0500/0700 AUV 47 L 9857 6P 0700

AS 47 C 7434 xP 0500/0700 AUV 47 L 9857 6P 0700 + Flange adaptor Ø32-Ø54 (Ref. 3719003)

AS 47 C 7438 xP 0500/0700 AUV 47 L 9857 6P 0700 + Hub adaptor Ø32-Ø54 (Ref. 3759833)

AS 47 C 7444 xP 0500/0700 AUV 47 L 9857 6P 0700 + Flange adaptor Ø32-Ø54 (Ref. 3719003)

AS 47 CK 7451 xM 0500/0700 AUV 47 L 9857 6P 0700 + Flange adaptor Ø32-Ø54 (Ref. 3719003)AUV in two-pipe configuration

AS 47 C 7461 xP 0500/0700 AUV 47 L 9857 6P 0700 + Flange adaptor Ø32-Ø54 (Ref. 3719003)

AS V 47 C 1627 xP 0500/0700 AUV 47 L 9857 6P 0700

AS 47 D 1539 xP 0500/0700 AUV 47 L 9857 6P 0700

AS 47 D 1550 xP 0500/0700 AUV 47 L 9857 6P 0700

AS 47 D 1557 xP 0500/0700 AUV 47 L 9857 6P 0700 One flat shaft (1)

AS 47 DK 1562 xP 0500/0700 AUV 47 L 9857 6P 0700

AS 47 D 7435 xP 0500/0700 AUV 47 L 9857 6P 0700 + Flange adaptor Ø32-Ø54 (Ref. 3719003)

AS 47 D 7439 xP 0500/0700 AUV 47 L 9857 6P 0700 + Hub adaptor Ø32-Ø54 (Ref. 3759833)

AS V 47 D 1696 xP 0500/0700 AUV 47 L 9857 6P 0700

(1) AS Model with 2 flats on the shaft, change coupling.

55

AL AUV Remarks

AL 35 A 9526 xP 0500/0700 AUV 47 R 9856 6P 0700

AL 35 A 9570 xP 0500/0700 AUV 47 R 9856 6P 0700

AL 35 A 9596 xP 0500/0700 AUV 47 R 9856 6P 0700

AL V 35 A 9626 xP 0500/0700 AUV 47 R 9856 6P 0700

AL 35 B 9580 xP 0500/0700 AUV 47 R 9856 6P 0700

AL 35 C 9528 xP 0500/0700 AUV 47 L 9857 6P 0700

AL 35 C 9540 xP 0500/0700 AUV 47 L 9857 6P 0700 + Inlet and return connections G1/8-G1/4

AL 35 C 9542 xP 0500/0700 AUV 47 L 9857 6P 0700

AL 35 C 9578 xP 0500/0700 AUV 47 L 9857 6P 0700

AL V 35 C 9628 xP 0500/0700 AUV 47 L 9857 6P 0700

AL 35 D 9529 xP 0500/0700 AUV 47 L 9857 6P 0700

6

56

AE AUV Remarks

AE 35 C 9850 xP AUV 47 L 9857 6P 0700 + Kit 991401

AE 47 A 1384 xP AUV 47 R 9856 6P 0700 + Kit 991401

AE 47 B 1366 xP AUV 47 R 9856 6P 0700 + Kit 991401

AE 47 B 7267 xP AUV 47 R 9856 6P 0700 + Kit 991401 + Hub adaptor Ø32-Ø54 (Ref. 3759833)

AE 47 C 1360 xP AUV 47 L 9857 6P 0700 + Kit 991401

AE 47 C 1386 xP AUV 47 L 9857 6P 0700 + Kit 991401

AE 47 C 1387 xP AUV 47 L 9857 6P 0700 + Kit 991401

AE 47 C 1394 xP AUV 47 L 9857 6P 0700 + Kit 991401 / One flat shaft (1)

AE 47 C 1397 xP AUV 47 L 9857 6P 0700 + Kit 991401

AE 47 C 7274 xM AUV 47 L 9857 6P 0700 + Kit 991401 + Flange adaptor Ø32-Ø54 (Ref. 3719003)AUV in two-pipe configuration

AE 47 C 7368 xP AUV 47 L 9857 6P 0700 + Kit 991401

AE 47 D 1378 xM AUV 47 L 9857 6P 0700 AUV in two-pipe configuration

AE 47 D 1385 xP AUV 47 L 9857 6P 0700

(1) AS Model with 2 flats on the shaft, change coupling.6

57

77. Spare parts and accessories

1

6

8

7

2

3

4 5

1 Shaft seal2 By-pass plug3 G 1/4 steel plug4 Filter5 Cover gasket6 Coil7 Solenoid tube8 Solenoid valve

587

Description Pump type Reference

Shaft seal (1) AN, AE, AS, AL, AUV, A2L, ALE, AR, AP, AT 991552

By-pass plug (2) AN, AE, AS, AL, AUV, A2L, ALE, AR, AP, AT 3779858

Plug (3)

AN, AE, AS, AL, AUV, A2L, ALE, AR, AP, ATG 1/4 steel plug 3779191

AN, AE, AS, AL, AUV, A2L, ALE, AR, AP, ATG 1/8 steel plug 3779835

Coil (6)

AS, AL, AUV, A2L, ALE, AR, AP, AT220-240 V ; 50/60 Hz 3713871SAV

AS, AL, AUV, A2L, ALE, AR, AP, AT110-120 V ; 50/60 Hz 3713824

AS, AL, AUV, A2L, ALE, AR, AP, AT24 V ; 50/60 Hz 3713823

59

Description Pump type Reference

Filter (4)

AN/AE/AS/AP 47/57/67Series 7000 - Rev. 3, 4, 5, 6Series 1000 - Rev. 1, 4, 5, 6

991530 (Height 20 mm)

AN/AE/AS/AP 47/57/67Series 7000 - Rev. 2

3715732 (Height 28 mm)(only for pumps manufactured after 1988)

AN/AE 77/97Series 7000 - Rev. 3, 4Series 1000 - Rev. 1, 6

3715750 (Height 23 mm)

AN/AE 77/97Series 7000 - Rev. 2

3715732 (Height 28 mm)(only for pumps manufactured after 1988)

AL/ALE/A2L/AR 35/55/65991530 (Height 20 mm)

AP2/AP3/AT2/AT3 45/55/65

AL/ALE/A2L/AR 75/953715750 (Height 23 mm)

AP2/AT2 75/95

AUV 991530 (Height 20 mm)

7

60

Description Pump type Reference

Cover gasket (5)

AN/AE/AS/AP 47/57/67/77/97Series 7000 - Rev. 4, 6Series 1000 - Rev. 4, 6

991524

AN/AE/AS/AP 47/57/67/77/97Series 7000 - Rev. 2, 3, 5Series 1000 - Rev. 1, 5

991523

AL/ALE/A2L/AR/AP2/AT2/AP3/AT3 35/45/55/65/75/95Series 9000 - Rev. 4, 6 991524

AL/ALE/A2L/AR/AP2/AT2/AP3/AT3 35/45/55/65/75/95Series 9000 - Rev. 1, 2, 5 991523

AUV 991524

Service kitAN, AE, AS, AL, AUV, A2L, ALE, AR, AP, AT - Low cover 991533

AN, AE, AS, AL, AUV, A2L, ALE, AR, AP, AT - High cover 991510

7

61

Description Pump type Reference

Solenoid tube (7)

AS/AP2/AP3 991430

AL rev. 2, 4, 5, 6

991502

AUV, AR, A2L

ALE 991600

7

62

Description Pump type Reference

Solenoid tube (7)

AP 991430

AT2/AT3rev. 2, 4, 6 991503

7

63

Description Pump type Reference

Solenoid valve (8)

AS220-240 V ; 50/60 Hz 991435

AS110-120 V ; 50/60 Hz 991431

AS24 V ; 50/60 Hz 991432

AL/AUV/A2L/AR220-240 V ; 50/60 Hz 3713871SAV + 991502

AL/AUV/A2L/AR110-120 V ; 50/60 Hz 3713824 + 991502

AL/AUV/A2L/AR24 V ; 50/60 Hz 3713823 + 991502

7

64

Description Pump type Reference

Solenoid valve (8)

AP220-240 V ; 50/60 Hz 991455

AP2/AP3220-240 V ; 50/60 Hz 991488

AT2/AT3220-240 V ; 50/60 Hz 3713871SAV + 991503

7

65

8

8. Connections

AN/AE AS/AL/ALE

AN/AE/AS/AL/ALE pumps

Figures are for "C" shaft rotation and nozzle outlet.

Figures are for "C" shaft rotation and nozzle outlet.

S : Suction G 1/8 or G 1/4N : Nozzle outlet G 1/8R : Return G 1/8 or G 1/4V : Vacuum gauge port G 1/8P : Pressure gauge port G 1/8A : Pressure adjustmentr : Rotation directionbp : By-pass plug for 2-pipe operation

V V

A A

P PP P

P P

N N

S Sr rR + bp R + bp

668

AUV 47 L 9857 6P 0700 AUV 47 R 9856 6P 0700

S : Suction G 1/4R : Return G 1/4N1 : Nozzle outlet G 1/8N2 : Optional nozzle outlet G 1/8V : Vacuum gauge port G 1/8P : Pressure gauge port G 1/8A : Pressure adjustmentr : Rotation directionbp : By-pass plug for 2-pipe operation

V V

N2 N1

A A

P P

N1 N2

S Sr rR + bp R + bp

AUV universal pump

67

9

9. One-pipe ↔ two-pipe configuration

Most SUNTEC pumps are delivered prepared for two-pipe installations. They can be converted to one-pipe operation by removing the internal by-pass plug and fitting a plug and a washer to the return port thus creating an internal recirculation circuit.

1-pipe(Remove by-pass plug)

2-pipe(By-pass plug inserted in return)

6810

10. Pipe Dimensions

Rated speed: 2850 rpm - Viscosity: 5 mm²/s (cSt) - Pressure: 9 barsThe annexed charts give the maximum length (in meters) of suction line as a function of 3 variables: lift between fuel unit and tank (H), nozzle capacity or pump type, pipe diameter (d), for an altitude of 200m above sea level and 0,45 bars vacuum. The length indicated (intersection of horizontal lines and columns) assumes the fitting of 4 right angle bends, 1 stop valve, 1 non return valve; if additional restrictions exist (particularly the filter of the suction line), the length must be reduced accordingly. Only mentioned diameters can be used, bigger pipes are not suitable.Altitude correction: if X is the altitude (different from 200m), - Lift system: add the value (X-200)/1000 to the real lift height "H", to obtain the equivalent lift, then determine the maximum length with the annexed charts. - Siphon feed system: reduce the real head height "H" by (X-200)/1000.E.g.: AS 47 pump in two-pipe lift system, with lift height = 1,5m, altitude = 700m, pipe diameter = 8mm.Equivalent lift height: 1,5+(700-200)/1000 = 2m, maximum pipe length = 26m.Pressure correction: only for one-pipe system.If P is the pressure (different from 9 bars), use the theoretical equivalent nozzle capacity = (√P/3) x real nozzle capacity.E.g.: one-pipe lift system, with nozzle = 0,60 GPH, pressure = 22 bars, pipe diameter = 4mm, suction height = 3m.Equivalent nozzle capacity = (√22 / 3)x0,60 = 0,94 GPH. The maximum pipe length is comprised between 17m (corresponding to 0,80 GPH) and 14m (corresponding to 1,00 GPH), that means around 15m.

69

10

One-pipe siphon feed system

One-pipe lift systemNozzle

Nozzle

70

Two-pipe siphon feed system

Two-pipe lift system

*Q = pump capacity @ 0 bar

Pump

Pump 35/45/47

35/45/47

55/57

55/57

65/67

65/67

75/77

75/77

95/97

95/97

10

71

11

11. FAQs

11.1 Pump is not running

Check if… Probable explanation Solution

…the motor is turning.

YES Motor coupling is defective or has came loose

Check coupling and repair or replace as appropriate.

NO

Pump has seized

Remove pump cover and check pump. If rust and / or an abnormal amount of dirt are found, check tank for water and check condition of filters. Replace pump.

Motor does not workTest motor and connections and repair or replace if necessary, having first examined the pump.

72

11

Check if… Probable explanation Solution

…oil flows out of the high-pressure port when it is loosened.

YES

Nozzle or in-line solenoid valve is blocked

Inspect nozzle and valve for blockage (dirt, grit, fuel,...)

Solenoid valve or pressure regulator is defective

Switch on the coil and check for magnetic pull. If there is no pull, check the current. If the current is OK, change the coil.

When the coil is in order, check the pressure regulating valve or replace the pump.

11.2 Pump is running but does not deliver oil

73

Check if… Probable explanation Solution

…no oil flows from the high-pressure port when it is loosened.

NO

Oil level in tank is low Check tank and refill.

Inlet pipe valve is closed Open the valve.

On a new installation, the check valve is the wrong way round

Check that all valves are facing the right way.

…and vacuum gauge shows a high vacuum.

YESBlockage up-stream Check in-line filter and non-return valve.

Pipe is undersized Check pipe dimensions.

11

74

Check if… Probable explanation Solution

…no oil flows from the high-pressure port when it is loosened.

…and vacuum gauge shows a low vacuum.

YES

Pump filter is plugged Remove pump cover and check filter condition.

Air leakCheck the tightness of pump cover (especially if the filter has recently been changed/cleaned) and check the cover gasket.

Pipe is oversized Very important for one-pipe systems. Check pipe diameter.

Pump rotates in a wrong way

If the installation is new, be sure that motor and pump rotation are the same. A pump turning in the wrong direction can not draw oil.

By-pass plug is missing in two-pipe installation Check if the by-pass plug is installed.

11

75

Check if… Probable explanation Solution

…no oil flows from the high-pressure port when it is loosened.

…and vacuum gauge shows a low vacuum.

YES

Suction and return lines have been swapped Check they have been correctly fitted.

Pump is worn out Check this by carrying out a pressure test.

11

76

Check if… Probable explanation Solution

…the pressure can be adjusted.

…and pressure gauge shows a low pressure.

YES

Pump is not properly sized for the nozzle performance (remembering fuel viscosity) or any hydraulic attachments i.e. hydraulically opened air flap

Change pump or nozzle as appropriate.

Pump is worn out Check this by carrying out a pressure test. Replace pump.

…and pressure gauge shows a high pressure.

YES Dirt in regulating valve Dismantle pressure regulator or replace pump.

11.3 Nozzle pressure is too high / too low

11

77

Check if… Probable explanation Solution

…the pressure can be adjusted.

…and the pump pressure oscillates.

YES

Air in the oil Check vacuum does not exceed 0,45 bars. Check suction line for leaks.

Pressure regulating valve is defective or clogged

Dismantle pressure regulator or replace pump.

Motor coupling is slipping Check coupling and check for speed variations.

…the pressure can not be adjusted.

…and the pressure is constantly too high or too low.

YES Pressure regulating valve is defective or clogged

Dismantle pressure regulator or replace pump.

NO Pressure gauge is defective or incorrectly installed Check pressure gauge. Bleed when fitting.

11

78

Check if… Probable explanation Solution

…an increasingly loud whine is coming from the pump.

YES Vacuum is too high (check with a vacuum gauge)

Check for closed valves, blocked filters, check valves that are stuck.

…the pump generates a cracking noise and the pressure gauge oscillates.

YES Air bubbles in the suction line Check suction line for leaks. Bleed pump if installation is one-pipe.

11.4 The oil pump makes noise

11

79

Check if… Probable explanation Solution

…a small nozzle flow is used with a one-pipe installation.

YESHeat build-up from recirculation in pump plus heat radiated from motor etc.

Convert to two-pipe or fit filter upstream from pump with return from pump to filter. This circulation outside of the burner will help to cool the system.

11.5 Excessive pump temperature

11

All rights reserved – Information and data are subject to change without prior notice.Edition 2017