PRAHER - QUALITY - SERVICE - INNOVATION
Technical data
General:
Power supply: 230 VAC 50/60 Hz 115 VAC 50/60 Hz 24 VAC 50/60 Hz
Digital time controlled backwash: 7 days 24 hourGrässlin digital clock (battery back up for timer 2 month)
Pressure switch:MSPS-FF-100SS: 0,69 - 6,9 barMSPS-FF-15SS: 0,10 - 1,0 bar
Filter- and backwash clock: 7 days 24 hourGrässlin digital clock (battery back up for timer 2 month)
Enclosure: IP 54
Valve type: 11/2” SM-TM, 2” SM-TM, 3” SM SM = S ide Mount TM = Top Mount
gradually adjustable!Backwash time: Rinse time:20 sec. - 11 min. 20 sec. - 4 min. 20 sec.Cut in delay: 25 sec. - 23 min.
Pump cut in delay: 20 sec.
Flow rate:31 1/2” 18 m /h (80 Gpm)3 2” 35 m /h (155 Gpm)3 3” 75 m /h (330 Gpm)
Operating pressure:
Valve ABS: max. 3,5 bar (20°C); GFK: 5 bar (20°C)
flange connections:
- Thread - Bolt - down flange- Clamp flange
Technical specification:
for exampel.:TYPE PRAHER Superstar E-6000 / F2 ABS 1 1/2” Side Mont valve
Features:
- water and chemical resistant pad switch- CE - approved (European electrical code)- Backwash, rinse time and cut in delay are gradually adjustable- pleasing design- ISO 9001- fast and trouble free installation- economic backwash valve solution for your filtersystem- E 6000 / F2 11/2” and 2” with manual override- free of corossion
only E - 3000 / F2
only E - 2000 / F2 UND E - 6000 / F2
only E - 6000 / F2 VERSION
Top Mount
- suitable for all well known filter brandsSubjects to technical modification!
M
I
K
L
B
H C
A
DEF
G
P
Q
N
1 1/2" 2" 3"
mm mm mm
A 99,0 110,0 170,0
B 182,0 228,0 330,0
C 32,0 38,0 50,0
D 47,0 60,0 85,5
E 60,0 81,0 110,0
F 164,0 210,0 306,0
G 270,0 312,0 436,0
H 38,0 34,0 50,0
I 87,5 115,0 165,0
K 175,0 230,0 330,0
L 250,0 250,0 250,0
M 160,0 160,0 160,0
N 280,0 322,0
P max. 378,0 420,0
Q max. 135,0 135,0
G
F
ED
A
CH
B
L
K
I
M
1 1/2”, 2”E-6000 / F2
long working life
durable
chemical resistant
100 % water resistant
E-2000 / F2E-3000 / F2 : 1 1/2”, 2”, 3”
E-6000 / F2: 3”
E - 2000 / F2;E - 3000 / F2
E - 6000 / F2
SymbolfotoE-2000 / F2 - 3”
SymbolfotoE-3000 / F2 - 1 1/2”
SymbolfotoE-6000 / F2 - 1 1/2”
Pressure Time int. Filter pump control unit
E - 2000 / F2
E - 3000 / F2
E - 6000 / F2
Control systemTYPE
SUPERSTAR E-2000 / F2 ; E-3000 / F2 ; E-6000 / F2
1 1/2”, 2”, 3” - 230V; 115V und 24V*
Side Mount connection:
BSP - thread ports
03 / 01 © by Ludwig PRAHER, AUSTRIA
PRAHER - QUALITY - SERVICE - INNOVATION
3" Side-Mount SM 30
3V
[m /
h]
p[bar]
2" Top-Mount TM 22
2" Side-Mount SM 20
1 ½" Side-Mount SM 10
1 ½" Top-Mount TM 12
Flow - pressure diagramm (backwash position)
1,0
80
60
40
20
0,80,60,40,2
3" Side-Mount SM 30
3
Flow - pressure loss diagramm (Filter position)
1 ½" Top-Mount TM 12
1 ½" Side-Mount SM 10
2" Side-Mount SM 20
2" Top-Mount TM 22
p[bar]
V[m
/ h]
1,0
80
60
40
20
0,80,60,40,2
I : Filtration of medium (i.e. water)Pool - pump - valve (to filter) - filter - Valve (from filter) - pool
II : Drainage of pool with pump:Pool - pump - valve - drain
III : Cleaning up filter medium (i.e. sand) in upstream (reversed flow in filter):Pool - pump - valve (from filter) - filter - valve (to filter) - drain
V : Cleaning of filter medium (i.e. sand) after backwash Pool - pump - valve (to Filter) - filter - valve (from filter) - drain
pump
pool
drain
filter bottom
filter topII Waste
pump
pool
drain
filter bottom
filter top
I FILTER
pump
pool
drain
filter bottom
filter topIII Backwash
pump
pool
drain
filter bottom
filter top
V RINSE
pump
pool
drain
filter bottom
filter top
Technical data
CONTACTS
Contacts for valve sequencing of multiple valves:
4 amperes max.
Contacts for fireman switch (heater willshut off prior to backwashing)
4 amperes max.
Contacts for pump in all actuator positions(Filter, Backwash, Rinse, Drain):
8 amperes max.
Contacts for position backwash and rinse(for secondary backwash pump or bloweror two speed pump):
4 amperes max.
Contacts for auxilliary valve or backwash monitoring:
8 amperes max.
Contacts for position backwash only:
4 amperes max.
SUPERSTAR E-2000 / F2 ; E-3000 / F2 ; E-6000 / F2
1 1/2”, 2”, 3” - 230V; 115V und 24V*
Field of application: Water treatment plant
18 19 20
13
27 2928
DELAY
VERZÖGERUNG
24 25 26
RINSEKLARSPšLEN RÜCKSPÜLEN
21 22 23
Serie
SEQUENCING
L1 N
BACKWASH
146 G 2
RR
LP004.0370.01.APraherPraher
sch
alte
r
sw
itch
pre
ssu
re
Dru
ck-
RÜ
CK
SP
ÜL
EN
BA
CK
WA
SH
N.O/6
N.C/2
COM/G
N.O/14
N.C/29
N.O/27
Backwash
Rinse
Pump
Dealy
N.C/26
N.O/24
COM/13
COM/25
COM/19
N.C/20
N.O/18
COM/22
Ball valve
N.C/23
N.O/21
sch
alte
r
24V~ba
ll v
alv
e
1N
~ 5
0/6
0H
z
Ku
ge
lha
hn
115V~
Pu
mp
Pu
mp
e
Serie
230V~
Po
we
r S
up
ply
sp
an
nu
ng
Backwash
COM/28
Ve
rso
rgu
ng
s-
109
sw
itch
Le
ve
l-
Niv
ea
u-