  • Page 1 1999 Lennox Industries Inc.

    Corp. 9710L7

    Service Literature

    SURELIGHT IGNITION SYSTEM

    Revised 92003

    SURELIGHT and BASIC SURELIGHT IGNITION SYSTEM

    IGENERALThe SureLight and Basic SureLight ignition system con

    sists of a Lennox control board (figure1) and hot surface

    ignitor . Figures 2 and 3 show the general location of the

    control board in multi and downflow position units. See

    table 2 for furnace model / igntion system matchup. Both

    models are similar except the SureLight board has a desig

    nated continuous blower speed and is protected by a

    circuit breaker located on the control box. Terminal desig

    nations are shown in table 3. The Basic SureLight board

    will energize HEATH heating speed for continuous blower

    and the control circuit is protected by an on board fuse. On

    both models the board and ignitor work in combination to

    ensure furnace ignition and ignitor durability. Both models

    control all major furnace operations. Tables 4 and 5 (Sur

    elight) and tables 6 and 7 (Basic Surelight) show jack plug

    terminal designations. Both boards also feature two LED

    lights for trouble shooting (see table 1 for diagnostic codes)

    and two accessory terminals. Terminal ACC energizes

    with the indoor blower on the SureLight board and terminal

    EACH energizes with the indoor blower on the Basic Sur

    elight. Terminal HTG ACC energizes when CAI is

    energized on the SureLight board and terminal HUMN en

    ergizes with CAI on the Basic SureLight board. The

    SureLight board has a built in heating isolation relay. See

    wiring diagram for heat anticipator settings.

    The ignitor used for both models is made of durable silicon

    nitride. Ignitor longevity is also enhanced by controlling the

    temperature of the ignitor. The board finds the lowest ignitor

    temperature which will successfully light the burner, thus in

    creasing the life of the ignitor.

    IMPORTANTIgnition control will not operate unless unit isproperly grounded. 120V supply must beinstalled with correct polarity.

    CAUTION

    Electrostatic discharge can affect electroniccomponents. Take precautions during furnaceinstallation and service to protect the furnaceselectronic controls. Precautions will help toavoid control exposure to electrostatic discharge by putting the furnace, the control andthe technician at the same electrostatic potential. Neutralize electrostatic charge by touchinghand and all tools on an unpainted unit surface,such as the gas valve or blower deck, before performing any service procedure.

    ELECTROSTATIC DISCHARGE (ESD)

    Precautions and Procedures

    Table of Contents

    I General Information 1. . . . . . . . . . . . . . . . . . . . . . . . .

    Board Diagnostic Codes 2. . . . . . . . . . . . . . . . . . . . . . .

    Board Terminal Designations 3. . . . . . . . . . . . . . . . . . .

    II Operation 6. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    III Furnace Wiring and Operation Sequence 8. . . . . .

    G23 8. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    80MGF 9. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    G26 10. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    GHR26 11. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    G24M 12. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    G40UH 13. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    G50UH 14. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    80UHG 15. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    90UGF 16. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    G27M 17. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    G32 18. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    G32V 19. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    GHR32 20. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    GHR32V 21. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Operation Sequence Flow Chart 23. . . . . . . . . . . . . . . .

    SureLight Board 23. . . . . . . . . . . . . . . . . . . . . . . . . . .

    Basic SureLight Board 28. . . . . . . . . . . . . . . . . . . . . .

    Troubleshooting Guide (both models) 32. . . . . . . . . . .

  • Page 2

    SURELIGHT INTEGRATED CONTROL BOARD

    FIGURE 1

    J58

    J156

    XFMRN

    BASIC SURELIGHT INTEGRATED CONTROL BOARD

    BOARD # 63K8901, 24L8501, 56L8301 and 97L4801BOARD # 12L6901 and 56L8401

    Both model boards are equipped with two LED lights for troubleshooting. The diagnostic codes are listed below in table 1.

    TABLE 1

    DIAGNOSTIC CODESMAKE SURE TO ID LEDS CORRECTLY: REFER TO INSTALLATION INSTRUCTIONS FOR CONTROL BOARD LAYOUT.

    LED #1 LED #2 DESCRIPTIONSIMULTANEOUS

    SLOW FLASHSIMULTANEOUS

    SLOW FLASHPower Normal operation

    Also signaled during cooling and continuous fan.

    SIMULTANEOUS FASTFLASH

    SIMULTANEOUS FASTFLASH

    Normal operation signaled when heating demand initiated at thermostat.

    SLOW FLASH ON

    Primary or Secondary limit open. Units with board 63K8901 or 24L8501 (SureLight) and units with board 12L6901 (Basic SureLight): Limit must close within 5trials for ignition or board goes into one hour limit Watchguard. Units with board

    56L8301, 97L48 (SureLight) and 56L8401 and 10M9301 (Basic SureLight): Limitmust close within 3 minutes or board goes into one hour limit Watchguard.

    OFF SLOW FLASH

    Pressure switch open or has opened 5 times during a single call for heat; OR:Blocked inlet/exhaust vent; OR: Condensate line blocked; OR: Pressure switch

    closed prior to activation of combustion air blower.

    ALTERNATING SLOWFLASH

    ALTERNATING SLOWFLASH

    Watchguard burners fail to ignite.

    SLOW FLASH OFF Flame sensed without gas valve energized.

    ON SLOW FLASHRollout switch open. OR: 9 pin (SureLight) or 12 pin (Basic SureLight) connector

    improperly attached.

    ONONOFF

    ONOFFON

    Circuit board failure or control wired incorrectly.

    FAST FLASH SLOW FLASH Main power polarity reversed. Switch line and neutral.

    SLOW FLASH FAST FLASH Low flame signal (see note below). Replace flame sense rod.

    ALTERNATING FASTFLASH

    ALTERNATING FASTFLASH

    Improper main ground or line voltage below 75 volts; OR: Broken ignitor; OR:Open ignitor circuit.

    NOTE Slow flash equals 1 Hz (one flash per second). Fast flash equals 3 Hz (three flashes per second). Normal flame signal for SureLight control is 0.61

    or greater microamps with a drop out signal of 0.20 or less microamps. Normal flame signal for Basic SureLight is 0.18 or greater micro amps with a dropout signal of 0.15 or less micramps.

  • Page 3

    TABLE 2

    ModelSureLight Ignition System

    Model 63K8901, 24L8501, 56L8301,97L4801

    Basic SureLight Ignition SystemModel 12L6901, 56L8401, 10M9301

    G23(X)

    80MGF

    G24M

    G27M

    G26 / GHR26

    90UGF

    G32Q/V

    GHR32Q/V

    G50UH

    80UHG

    G40UH

    TABLE 3

    IGNITION CONTROL BOARD TERMINAL DESIGNATIONS

    SureLight Terminals Basic SureLight Terminals Function

    ACB COOL COOLH Blower Cooling Speed 120V

    ACB HEAT HEATH BlowerHeating Speed 120V

    ACC EACH Accessory / Electronic Air Cleaner 120V

    HTG ACC HUMH Heat Accessory / Humidifier 120V

    24VAC HOT XFMRH Transformer 24V Hot

    24VAC RTN XFMRN Transformer Neutral

    HOT LINEH 120V Hot Input

    NEUTRAL LINEN 120V Neutral

    PARK (dead) PARK (dead) Alternate Speed Taps

    TX 120V To Transformer

    FLAME SENSE FLAME SENSE Flame Sense

    HUMN Humdifier Neutral

    EACN Electronic Air Cleaner Neutral

    CIRN Blower Neutral

  • Page 4

    TABLE 4

    SURELIGHT BOARD J156 (J2) TERMINAL DESIGNATIONS

    PIN # FUNCTION

    1 Ignitor

    2 Not Used

    3 Ignitor Neutral

    4 Combustion Air Inducer Line Voltage

    5 Not Used

    6 Combustion Air Inducer Neutral

    TABLE 5

    SURELIGHT BOARD J58 (J1) TERMINAL DESIGNATIONS

    PIN # FUNCTION

    1 Primary Limit In

    2 Gas Valve Common

    3 Roll Out Switch Out

    4 Gas Valve 24V

    5 Pressure Switch In

    6 Pressure Switch and Primary Limit Out

    7 Not Used

    8 Roll Out Switch In

    9 Ground

    TABLE 6

    BASIC SURELIGHT BOARD J156 (J2) TERMINAL DESIGNATIONS

    PIN # FUNCTION

    1 Combustion Air Inducer Line

    2 Ignitor Line

    3 Combustion Air Inducer Neutral

    4 Ignitor Neutral

    TABLE 7

    BASIC SURELIGHT BOARD J58 (J1) TERMINAL DESIGNATIONS

    PIN # FUNCTION

    1 Secondary Limit

    2 Not Used

    3 24V

    4 Not Used

    5 Rollout Switch In

    6 24V

    7 Primary Limit

    8 Ground

    9 Gas Valve In

    10 Pressure Switch Out

    11 Rollout Switch Out

    12 Gas Valve Out

  • Page 5

    FIGURE 2

    G40UH(X) HORIZONTAL POSITION

    BASIC SURELIGHT CONTROLBOARD

    FIGURE 3

    G32V

    SURELIGHT CONTROL BOARD

  • Page 6

    IIOPERATION (Both Models)

    FAN TIMER CONTROL

    The fan on time (during heat mode) of 45 seconds is notadjustable. Fan off time (time that the blower operates after

    the heat demand has been satisfied) can be adjusted by

    flipping the dip switches located on the SureLight integrated control. The unit is shipped with a factory fan off

    setting of 90 seconds. Fan off time will affect comfort and is

    adjustable to satisfy individual applications. There is nofanon or fanoff time during cool mode. Fan energizes

    upon demand for cool and deenergizes when demand issatisfied. See figure 4 for fanoff time adjustment.

    FIGURE 4

    FANOFF TIME ADJUSTMENT

    To adjust fanoff timing, flip dip switch (black) to desired setting.

    60sec. 90sec. 120sec. 180sec.

    ELECTRONIC IGNITIONOn a call for heat the control monitors the combustion airblower pressure switch. The control will not begin the heat

    ing cycle if the pressure switch is closed (jumpered). Once

    the pressure switch is determined to be open, the combustion air blower is energized. When the differential in the

    pressure switch is great enough the pressure switch

    closes and a 15second prepurge begins. If the pressureswitch is not proven within 21/2 minutes, the control goes

    into WatchguardPressure Switch mode for a 5minute re

    set period.

    After the 15second prepurge period, the ignitor warms

    up for 20 seconds,during which the gas valve opens at 19seconds for a 4 second trial for ignition. See figure 5 . The

    ignitor energizes for the first second of the 4second trial.

    BOARD 97L4801 and 10M9301 ONLY: ignitor energizesthe entire 4 second trial, or until flame is sensed (which

    ever is first). If ignition is not proved during the 4secondperiod, the control will try four more times. After a total of

    five trials for ignition (including the initial trial), the control

    goes into WatchguardFlame Failure mode. After a60minute reset period, the control will begin the ignition

    sequence again.

    The control board has an added feature that prolongs thelife of the ignitor. After the first successful ignition, the con

    trol lowers the ignitor temperature on successive calls forheat. The control continues to lower the ignitor tempera

    ture until it finds the lowest temperature that will provide a

    successful ignition. It finds this by ramping down until the

    ignitor will not light, then steps up by 3 times. Lower tem

    perature means a cooler ignitor which prolongs ignitor

    life. This amount is used for 255 cycles . On the 256th call

    for heat, the control will again ramp down until the lowest

    ignitor temperature is determined and the cycle begins

    again.

    GAS VALVE

    Gas valves used will be manufactured by White Rodgers

    or Honeywell. The valves are internally redundant to as

    sure safety shut off. The valve on the G27M, G32(V) and

    GHR32(V) provides twostage heat. 24VAC terminals on

    top of the valves are connected to wires from the SureLight

    ignition control Jackplug J58 (some boards will have J1).

    FLAME SENSING AND RECTIFICATION

    The SureLight ignition system uses a sensing probe to

    verify flame conditions through flame rectification. The

    sensing probe functions quite differently from a thermo

    couple in a standard furnace.

    Flame rectification is the property of a gas flame which per

    mits it to act as a DC current path between two metal

    objects, when an AC voltage is applied between the two

    objects that are enveloped in a gas flame. An AC voltage is

    applied to the flame sensor and burner/burner crossover

    by the SureLight circuitry. Electrons are discharged alter

    nately from the burner/crossover to the sensor and back.

    More electrons will hit the burner and crossover than sen

    sor since the grounding area is so much larger. The end

    result is a pulsating DC current flowing through the flame in

    one direction (flame sensor to burner crossover) which is

    of a larger magnitude than the current flowing in the oppo

    site direction (burner crossover to flame sensor).This

    pulsating DC current is the only type of signal which the

    SureLight board will accept as proof of flame. See figures

    6 , 7 and 8 .

    IGNITOR

    The SureLight ignitor is made of durable silicon nitride. Ig

    nitor longevity is enhanced by controlling voltage to the

    ignitor. The board finds the lowest ignitor temperature

    which will successfully light the burner, thus increasing the

    life of the ignitor. Due to this feature of the board, voltage

    cannot be measured so ignitor must be ohmned. Ohm

    value should be between 10.9 and 19.7. See figures 6 ,

    7 and 8 for ignitor location.

  • Page 7

    DEMANDCAI

    GAS VALVE

    15

    ON

    OFF

    38

    IGNITOR

    341

    Pre Purge Ignitor Warmup Trial forIgnition

    Post Purge

    5 SEC80

    *Blower on time will be 45 seconds after gas valve is energized. Blower off time will depend on OFF TIME" Setting.

    INDOOR BLOWER

    FIGURE 5

    Blower On"Delay

    SureLight Control Ignition Sequence

    35

    FLAME SENSORSURELIGHT IGNITOR

    SureLight Ignitor and SensorG27M, G24M, 80MGF and 80UHG

    FIGURE 6

    GAP TO BURNER = 1/4" GAP TO BURNER = 1/4"

    SURELIGHT IGNITOR

    FLAME SENSOR

    SureLight Ignitor and SensorG23(X),G26, 90UGF, GHR26, G32/V and GHR32/V

    FIGURE 7

    GAP TO BURNER = 1/4" GAP TO BURNER = 3/8"

    SureLight Ignitor and SensorG40UHG and G50UHG

    FIGURE 8

    SURELIGHT INGITOR

    FLAME SENSOR

    GAP TO BURNER = 5/16" GAP TO BURNER = 5/16"

  • Page 8

    IIISEQUENCE OF OPERATION AND WIRING DIAGRAMAG23

  • Page 9

    BG24M

  • Page 10

    CG26

  • Page 11

    DG40UH

  • Page 12

    EG50UH

  • Page 13

    FGHR26

  • Page 14

    G80MGF

  • Page 15

    H80UHG

  • Page 16

    I90UGF

    Sequence of Operation G23X / 80MGF / G26 / GHR26 / 90UGF / 80UGH / G24MG40UH/G50UH 1 When there is a call for heat, W1 of the thermostat en

    ergizes W of the furnace control with 24VAC.

    2 S10 primary limit switch and S47 rollout switch areclosed. Call for heat can continued.

    3 SureLight control energizes combustion air inducerB6. Combustion air inducerruns until S18 combustionair prove switch closes (switch must close within 21/2minutes or control goes into 5 minute WatchguardPressure Switch delay). Once S18 closes, a 15second prepurge follows.

    4 SureLight control energizes ignitor. A 20secondwarmup period begins.

    5 Gas valve opens for a 4second trial for ignition.

    6 Flame is sensed, gas valve remains open for the heatcall.

    7 After 45second delay, SureLight control energizes indoor blower B3.

    8 When heat demand is satisfied, W1 of the indoor thermostat deenergizes W of the SureLight control whichdeenergizes the gas valve. Combustion air inducerB6 continues a 5second postpurge period, and indoor blower B3 completes a selected OFF time delay.

  • Page 17

    JG27M

  • Page 18

    KG32

  • Page 19

    LG32V

  • Page 20

    MGHR32

  • Page 21

    NGHR32V

  • Page 22

    Sequence of Operation G27M / G32 / G32V GHR32 / GHR32VIgnitor operation will vary between SureLight boards.

    Boards 56L83, 24L85 and 63K89 will energize the ignitor

    for the first second of the 4second ignition trial. Board

    97L48 will energize the ignitor for the full 4second igntion

    trial.

    1 When there is a call for heat, W1 of the thermostat en

    ergizes W of the furnace control with 24VAC.

    2 SureLight control runs selfcheck for S10 primary limit

    switch and S21 secondary limit switch normally

    closed contacts. The control also checks S18 com

    bustion air prove switch and S102 high fire pressure

    switch normally open contacts.

    3A Singlestage Mode, SingleStage Thermostat Sur

    eLight control energizes combustion air inducer B6 on

    high speed. Combustion air inducer runs until S102

    high fire pressure switch closes (switch must close

    within 21/2 minutes or control goes into 5 minute

    WatchguardPressure Switch delay). A 15second

    prepurge follows after S102 closes.

    3B Twostage Mode, SingleStage Thermostat Sur

    eLight control energizes combustion air inducer B6 on

    low speed. Combustion air inducer runs until combus

    tion air inducer switch S18 closes (switch must close

    within 21/2 minutes or control goes into 5 minute

    WatchguardPressure Switch delay). A 15second

    prepurge follows once S18 closes.

    3C Twostage Mode, Two Stage Thermostat Sur

    eLight control energizes combustion air inducer B6 on

    low speed. Combustion air inducer runs until combus

    tion air inducer switch S18 closes (switch will close

    within 21/2 minutes or control goes into 5 minute

    WatchguardPressure Switch delay). A 15second

    prepurge follows once S18 is closes.

    4 SureLight control energizes ignitor. A 20second

    warmup period begins.

    5A Singlestage Mode, SingleStage Thermostat

    Gas valve is energized on first stage heat (low). Gas

    valve opens for a 4 second trial for ignition. Flame is

    sensed. After 8 seconds from when gas valve opens,

    valve energizes on second stage (high heat).

    5B Twostage Mode, SingleStage Thermostat Gas

    valve is energized on first stage. Gas valve opens for

    a 4second trial for ignition. Signal is sent from control

    module to twostage control board to begin W2 (sec

    ondstage) ON delay.

    5C TwoStage Mode, Two Stage Thermostat Gas

    valve is energized on first stage only. Gas valve opens

    for a 4second trial for ignition.

    6 Flame is sensed, gas valve remains open for the heat

    call.

    7A Singlestage Mode, SingleStage Thermostat Af

    ter 45second delay, indoor blower B3 is energized on

    high heating speed.

    7B Twostage Mode, SingleStage Thermostat Af

    ter 45second delay, indoor blower B3 is energized on

    low speed.

    7C TwoStage Mode, Two Stage Thermostat After

    45second delay, indoor blower B3 is energized on

    low speed.

    8A Twostage Mode, SingleStage Thermostat Sec

    ond stage time on delay complete (8, 12, or 15

    minutes). Gas valve opens, indoor blower B3 remains

    energized on heating speed.

    8B TwoStage Mode, Two Stage Thermostat Call

    for second stage heat comes from indoor thermostat.

  • Page 23

    PROVE SWITCH WATCHGUARD(5 MINUTES)

    COMBUSTION AIR INDUCER OFF.INDOOR BLOWER OFF.

    LED #1 OFFLED #2 SLOW FLASH

    HIGHFIRE PROVESWITCH CLOSED?

    GAS VALVE OFF.COMBUSTION AIR INDUCER OFF.

    INDOOR BLOWER OFF WITH DELAY.LED #1 OFF

    LED #2 SLOW FLASH(Sequence holds until pressure switchcloses or thermostat resets control.)

    HEATING SEQUENCE OF OPERATION

    NORMAL HEATING MODE ABNORMAL HEATING MODE

    CONTROL SELFCHECK OKAY?

    BURNER OFF?(CONTINUOUS FLAME CHECK)

    NORMAL OPERATION:LED #1 SLOW FLASHLED #2 SLOW FLASH

    YES

    YES

    YES

    GAS VALVE OFF. COMBUSTION AIR INDUCER OFF.INDOOR BLOWER DELAY OFF.

    LED #1 ONLED #2 ON

    (RESET CONTROL BY TURNING MAIN POWER OFF.)

    POLARITY REVERSED.LED #1 FAST FLASHLED #2 SLOW FLASH

    POWER ON

    COMBUSTION AIR INDUCER ON FOR 1 SECOND.

    ROLLOUT SWITCH CLOSED?

    THERMOSTAT CALLS FOR HEAT:LED #1 FAST FLASHLED #2 FAST FLASH

    GAS VALVE OFF. COMBUSTION AIR INDUCER OFF.INDOOR BLOWER OFF WITH DELAY.LED #1 ON. LED #2 SLOW FLASH.

    SEQUENCE HOLDS UNTIL ROLLOUT SWITCH CLOSES.

    GAS VALVE OFF. COMBUSTION AIR INDUCER ON.INDOOR BLOWER ON HEATING SPEED.

    LED #1 SLOW FLASHLED #2 OFF

    NO

    YES

    NO

    IS THEREPROPER GROUND?

    IS VOLTAGEABOVE 75 VOLTS?

    LOW VOLTAGE SIGNAL AT LED HOLDSUNTIL VOLTAGE RISES ABOVE 75 VOLTS.

    NO

    YESNO

    SIGNAL IMPROPERGROUND AT LED.SIGNAL HOLDSUNTIL UNIT IS

    PROPERLYGROUNDED.

    NO

    NO

    CONTINUED NEXT PAGE

    PRIMARY & SECONDARY LIMIT SWITCHES CLOSED?

    COMBUSTION AIR INDUCER OFF.INDOOR BLOWER ON.LED #1 SLOW FLASH

    LED #2 ON

    NO

    YES

    NO

    TWOSTAGE MODECALL FOR 1ST STAGE HEAT

    TWOSTAGE MODESINGLE STAGE TSTAT

    SINGLESTAGE MODEHIGH HEAT ONLY

    COMBUSTION AIR INDUCERON LOW SPEED ( 2.5 MINUTES)

    LOWFIRE PROVESWITCH CLOSED?

    PREPURGE15 SECONDS

    COMBUSTION AIR INDUCERON HIGH SPEED ( 2.5 MINUTES)

    NONO

    YES YES

    YES

    PROVE SWITCH CONTACTS OPEN?(HIGH AND LOW FIRE)

    G26, GHR26, 90UGF, G24M, G23X, 80MGF,G27M, G32, G32V, GHR32, GHR32V and G50UH

    SEQUENCE

    G27M,G32, G32V,GHR32 and GRH32V

    SEQUENCEONLY

    GAS VALVE OFF. COMBUSTION AIR INDUCER ON.INDOOR BLOWER ON.

    LED #1 ALTERNATING FAST FLASHLED#2 ALTERNATING FAST FLASHCHECK FOR BROKEN IGNITOR OR

    OPEN IGNITOR CIRCUIT

    YES

    POLARITYOKAY?

    IS COMBUSTION AIR INDUCER ENERGIZED?(HTG ACC ENERGIZES WITH C.A.I.)

    *G26, GHR26, 90UGF, G24M,G23X , 80MGF and G50UH

    SEQUENCE ONLY

  • Page 24

    GAS VALVE OFF.COMBUSTION AIR INDUCER OFF.

    INDOOR BLOWER OFF WITH DELAY.LED #1 OFF

    LED #2 SLOW FLASH(Sequence holds until pressure switchcloses or thermostat resets control.)

    *IS COMBUSTION AIR INDUCER ENERGIZED?(HTG ACC TERMINAL IS ENERGIZED WITH C.A.B)

    *HAS COMBUSTION AIR PROVE SWITCHCLOSED IN 2.5 MINUTES?

    YES

    *15SECOND COMBUSTION AIR INDUCERPREPURGE INITIATED BY CLOSED PROVE SWITCH.

    YES

    YES

    HEATING SEQUENCE CONTINUED

    IGNITOR WARMUP 20 SECONDS.

    YES

    4SECOND TRIAL FOR IGNITION. GAS VALVE OPENS. BOARDS 63K89, 24L85AND 56L83: IGNITOR ENERGIZED FOR1 SECOND AFTER VALVE OPENS.BOARD 97L48,: IGNITOR ENERGIZED THE FULL 4SECOND TRIAL FOR

    IGNITION. NO FLAME SENSED DURING THIS PERIOD.

    YES

    FLAME STABILIZATION PERIOD.

    4 SECONDS

    TWOSTAGE MODESINGLE STAGE TSTAT

    SINGLESTAGE MODEHIGH HEAT ONLY

    TWOSTAGE MODECALL FOR 1st STAGE HEAT

    GAS VALVE OPENHIGH AND LOW FIRE

    MAIN GAS VALVE OPENLOW FIRE ONLY

    MAIN GAS VALVE OPENLOW FIRE ONLYSECOND STAGETIME ON BEGINS

    4 SECONDS

    FLAME PRESENT?

    YES

    FLAME SIGNAL ABOVE 0.7 MICROAMPS?

    YES

    INDOOR BLOWER ON DELAY BEGINS. AFTER 45SECOND DELAY, ACB HEAT SPEED TERMINAL IS

    ENERGIZED. ACC TERMINAL IS ENERGIZED.

    YES

    FLAME RECTIFICATION CURRENT CHECKCAN FLAME BE PROVEN WITHIN 4

    SECONDS AFTER GAS VALVE OPENS?(0.15 microamps)

    INDOOR BLOWERON LOW SPEED

    INDOOR BLOWERON HIGH HEATING SPEED

    TWOSTAGE MODESINGLE STAGE TSTAT

    SINGLESTAGE MODEHIGH HEAT ONLY

    TWOSTAGE MODECALL FOR 1st STAGE HEAT

    CONTINUED NEXT PAGE

    YES

    *IS COMBUSTION AIRPROVE SWITCH OPEN?

    PROVE SWITCH WATCHGUARD(5 MINUTES)

    COMBUSTION AIR INDUCER OFF.INDOOR BLOWER OFF.

    LED #1 OFFLED #2 SLOW FLASH

    NO

    HAS CONTROL RESET IGNITIONSEQUENCE FOUR TIMES?

    YES

    NO

    WATCHGUARD MODE. GAS VALVE OFF.COMBUSTION AIR INDUCER OFF.

    INDOOR BLOWER OFF WITH DELAYLEDs SIGNAL WATCHGUARD FAILURE CODE.

    IS 60MINUTE RESET PERIOD COMPLETE?

    YES

    GAS VALVE OFF. COMBUSTION AIR INDUCER ON.INDOOR BLOWER OFF.

    HAS CONTROL FAILED TO SENSE FLAME FORFIVE CONSECUTIVE TRIES DURING A SINGLE

    HEAT DEMAND?

    LOW FLAME SIGNAL(Does not affect operation of control)

    LED #1 SLOW FLASHLED #2 FAST FLASH

    NO

    NO

    NO

  • Page 25

    DEMAND FOR HEAT SATISFIED.THERMOSTAT OPENS.

    TWOSTAGE MODECALL FOR 1st STAGE HEAT

    HEATING SEQUENCE CONTINUED

    PRIMARY AND SECONDARY LIMITSWITCHES CLOSED?

    COMBUSTION AIR PROVESWITCH CLOSED?

    YES

    ROLLOUT SWITCH CLOSED?

    YES

    GAS VALVE DEENERGIZED.COMBUSTION AIR INDUCER DEENERGIZED.

    INDOOR BLOWER ON UNTIL SWITCH CLOSES.LED #1 SLOW FLASH. LED #2 ON.

    IS LIMIT SWITCH CLOSED?

    YES

    HAS PRIMARY/SECONDARY LIMIT RESET(see table 1 DIAGNOSTIC CODES for limit reset operation)

    NO

    GAS VALVE OFF. COMBUSTION AIR INDUCER OFF.INDOOR BLOWER OFF WITH DELAY.LED #1 ON. LED #2 SLOW FLASH.

    SEQUENCE HOLDS UNTIL ROLLOUT SWITCH CLOSES.

    NO

    GAS VALVE DEENERGIZED.COMBUSTION AIR INDUCER ON.

    INDOOR BLOWER OFF WITH DELAYLED #1 OFF. LED #2 SLOW FLASH.

    HAS CAB SWITCH CLOSED IN 2.5 MINUTES?

    YESNO

    15SECOND COMBUSTION AIR INDUCER PREPURGEINITIATED BY CLOSED PRESSURE SWITCH.

    WATCHGUARD MODE. GAS VALVE OFF.COMBUSTION AIR INDUCER OFF.

    INDOOR BLOWER OFF WITH DELAYLEDs SIGNAL WATCHGUARD FAILURE CODE.

    IS 60MINUTE RESET PERIOD COMPLETE?

    YES

    NO

    NO

    5MINUTE PROVE SWITCHWATCHGUARD MODE.

    THERMOSTAT DEMAND SATISFIED.

    LED #1 & #2 SIMULTANEOUS SLOW FLASHES.

    COMB. AIR INDUCER CONTINUES 5SECOND. POSTPURGE AFTER TSTAT DEMAND IS SATISFIED. IN

    DOOR AIR BLOWER COMPLETES SELECTED OFF"DELAY BEFORE SHUTTING OFF. ACB HEAT SPEED,

    HTG ACC AND ACC TERM. DEENERGIZE.

    YES

    YES

    YES

    INDOOR BLOWER ONHEAT SPEED?

    TWOSTAGE MODESINGLE STAGE TSTAT

    PROVE SWITCH CLOSED?

    CALL FOR 2nd STAGEHEAT (HIGH FIRE)

    FROM THERMOSTAT

    2nd STAGE ON DELAYON CONTROL BOARD

    COMPLETE (8, 12 OR 15 MIN.)

    YES

    HIGH FIRE PROVE SWITCH CLOSED?

    HIGH FIRE GAS VALVE OPEN? (8 SEC. DELAY)

    NOYES YES

    COMBUSTION AIR INDUCER ON HIGH SPEED?

    NO

    TWOSTAGE MODESINGLE STAGE TSTAT

    SINGLESTAGE MODEHIGH HEAT ONLY

    TWOSTAGE MODECALL FOR 1st STAGE HEAT

    CONTROL CHECKS: FLAME PRESENCE, CLOSED PRIMARY& SECONDARY LIMITS, CLOSED PROVE SWITCHES,

    CONTINUOUSLY CLOSED ROLLOUT SWITCHES (duringheating cycle).

    SEE PREVIOUS SEQUENCES FOR FAILURE MODES.

    GAS VALVE DEENERGIZED.

    COMBUSTION AIR INDUCERPOSTPURGE 5 SECONDS.

    INDOOR BLOWERSELECTED TIME OFF DELAY.

  • Page 26

    COOLING SEQUENCE OF OPERATION

    NORMAL COOLING MODE ABNORMAL COOLING MODE

    IGNITION CONTROL MAIN POWER ON.

    CONTROL SELF DIAGNOSTIC CHECK.IS CONTROL OPERATING NORMALLY?

    YES

    SIGNAL POLARITY REVERSED AT LED.

    POWER ON

    GAS VALVE OFF. COMBUSTION AIR INDUCER OFF.INDOOR BLOWER OFF WITH NORMAL DELAY.

    SIGNAL CIRCUIT BOARD FAILURE AT LED.INTERRUPT MAIN POWER TO RESET CONTROL.

    YES

    TURN INDUCER ON FOR 1 SECOND.

    IS POLARITY REVERSED?

    ROLLOUT SWITCH MONITORED CONTINUOUSLY.IS ROLLOUT SWITCH CLOSED?

    CHECK FOR MAIN BURNER FLAME SENSE.IS MAIN BURNER FLAME OFF?

    LED: SLOW FLASH RATE REMAINS UNCHANGEDTHROUGHOUT COOLING CYCLE.

    THERMOSTAT CALLS FOR COOLING.

    COMPRESSOR CONTACTOR AND SYSTEM FANENERGIZED WITH 0SECOND DELAY. ACB COOL

    SPEED IS ENERGIZED. ACC TERMINAL IS ENERGIZED.

    COMPRESSOR OFF.

    THERMOSTAT OPENS.

    SYSTEM FAN AND ACC. TERM. OFFWITH 0SECOND DELAY.

    NO

    YES

    NO

    GAS VALVE OFF. COMBUSTION AIR INDUCER OFF.INDOOR BLOWER OFF WITH NORMAL DELAY.

    SIGNAL CIRCUIT BOARD FAILURE AT LED.SEQUENCE HOLDS UNTIL ROLLOUT SWITCH CLOSES.

    NO

    GAS VALVE OFF. COMBUSTION AIR INDUCER OFF.INDOOR BLOWER OFF WITH NORMAL DELAY.

    SIGNAL CIRCUIT BOARD FAILURE AT LED.SEQUENCE HOLDS UNTIL FLAME IS NOT SENSED.

    NO

    IS THEREPROPER GROUND?

    IS VOLTAGEABOVE 75 VOLTS?

    LOW VOLTAGE SIGNAL AT LED HOLDSUNTIL VOLTAGE RISES ABOVE 75 VOLTS.

    NOYES

    NO

    SIGNAL IMPROPERGROUND AT LED.SIGNAL HOLDSUNTIL UNIT IS

    PROPERLYGROUNDED.

  • Page 27

    CONTINUOUS LOW SPEED FAN SEQUENCE OF OPERATIONSURELIGHT CONTROL

    LED: SLOW FLASH RATE REMAINSUNCHANGED THROUGHOUT SEQUENCE.

    MANUAL FAN SELECTION MADE AT THERMOSTAT.CONTROL (G) ENERGIZES SYSTEM FAN AT ACBLOW SPEED. ACC. TERMINAL IS ENERGIZED.

    THERMOSTAT CALLS FOR HEAT (W).

    THERMOSTAT CALLS FOR COOLING.

    BOARD NO. 63K8901SYSTEM FAN DEENERGIZED. SYSTEM FANENERGIZES ON ACB HEAT SPEED AFTER

    NORMAL DELAY.

    THERMOSTAT OPENS. COMBUSTION AIRAND HTG ACC TERMINAL DEENERGIZE.

    SYSTEM FAN SWITCHED TO ACB COOLSPEED. ACC. TERM. REMAINS ON.

    THERMOSTAT OPENS.

    BOARD 63K89: SYSTEM FAN OFF. ACC. TERM.OFF. (AFTER OFF DELAY COMPLETED).

    MANUAL FAN SELECTION MADE AT THERMOSTAT.CONTROL (G) ENERGIZES SYSTEM FAN AT ACB

    LOW SPEED. ACC. TERM. ENERGIZED.

    NO YES

    YESNO

    HTG ACC. TERM. ENERGIZES WITH COMB. AIR BLOWER.

    BOARD NO. 24L85, 56L83, 97L48SYSTEM FAN SWITCHES TO ACB HEAT SPEEDAFTER NORMAL DELAY (fan remains energized)

    BOARDS 24L85, 56L83 AND 97L48:SYSTEM FAN SWITCHES TO

    LOW SPEED AFTER NORMAL DELAY.(fan remains energized)

  • Page 28

    HEATING SEQUENCE OF OPERATION

    NORMAL HEATING MODE ABNORMAL HEATING MODE

    CONTROL SELFCHECK OKAY?

    BURNER OFF?(CONTINUOUS FLAME CHECK)

    NORMAL OPERATION:LED #1 SLOW FLASHLED #2 SLOW FLASH

    YES

    YES

    YES

    GAS VALVE OFF. COMBUSTION AIR INDUCER OFF.INDOOR BLOWER DELAY OFF.

    LED #1 ONLED #2 ON

    (RESET CONTROL BY TURNING MAIN POWER OFF.)

    POLARITY REVERSED.LED #1 FAST FLASHLED #2 SLOW FLASH

    POWER ON

    IS POLARITY REVERSED?

    ROLLOUT SWITCH CLOSED?

    THERMOSTAT CALLS FOR HEAT:LED #1 FAST FLASHLED #2 FAST FLASH

    IS COMBUSTION AIRPROVE SWITCH OPEN?

    GAS VALVE OFF. COMBUSTION AIR INDUCER ON.INDOOR BLOWER ON.

    LED #1 ON. LED #2 SLOW FLASH.SEQUENCE HOLDS UNTIL ROLLOUT SWITCH CLOSES.

    GAS VALVE OFF. COMBUSTION AIR INDUCER ON.INDOOR BLOWER ON HEATING SPEED.

    LED #1 SLOW FLASHLED #2 OFF

    GAS VALVE OFF.COMBUSTION AIR INDUCER OFF.

    INDOOR BLOWER OFF WITH DELAY.LED #1 OFF

    LED #2 SLOW FLASH(Sequence holds until pressure switchcloses or thermostat resets control.)

    NO

    NO

    YES

    NO

    IS VOLTAGEABOVE 75 VOLTS?

    LED SIGNALS WAITING ON CALL FROMTHERMOSTAT. CONTROL WILL NOT RESPOND

    UNTIL VOLTAGE RISES ABOVE 75 VOLTS.

    NO

    NO

    NO

    IS COMBUSTION AIR INDUCER ENERGIZED?

    HAS COMBUSTION AIR PROVE SWITCHCLOSED IN 2.5 MINUTES?

    YES

    YESPROVE SWITCH IS IN WATCHGUARD MODE.

    GAS VALVE OFF. COMBUSTION AIR INDUCER OFF.INDOOR BLOWER OFF WITH DELAY.

    LED #1 OFF. LED #2 SLOW FLASH.IS 5MINUTE RESET PERIOD COMPLETE?

    NO

    PRIMARY AND SECONDARY LIMIT SWITCH.CLOSED?

    YES

    YES

    CONTINUED NEXT PAGE

    COMBUSTION AIR INDUCER OFF.INDOOR BLOWER ON

    LED #1 SLOW FLASH RATELED #2 ON

    NO

    YES

    YES

    NO

    YES

    G40UH and 80UHGONLY SEQUENCE

  • Page 29

    HEATING SEQUENCE CONTINUED

    NORMAL HEATING MODE ABNORMAL HEATING MODE

    FLAME RECTIFICATION CURRENTCHECK. CAN FLAME BE PROVEN WITHIN4 SECONDS AFTER GAS VALVE OPENS?

    (0.15 microamps)

    FLAME PRESENT?

    INDOOR BLOWER ON DELAY BEGINS(45 seconds.)

    PRIMARY AND SECONDARY LIMITSWITCHES CLOSED?

    COMBUSTION AIR PROVESWITCH CLOSED?

    LOW FLAME SIGNAL(Does not affect operation of control)

    LED #1 SLOW FLASHLED #2 FAST FLASH

    GAS VALVE DEENERGIZED.COMBUSTION AIR INDUCER DEENERGIZED.

    INDOOR BLOWER ON UNTIL SWITCH CLOSES.LED #1 SLOW FLASH. LED #2 ON.

    IS LIMIT SWITCH CLOSED?

    GAS VALVE DEENERGIZED.COMBUSTION AIR INDUCER ON.

    INDOOR BLOWER OFF WITH DELAYLED #1 OFF. LED #2 SLOW FLASH.

    HAS CAB SWITCH CLOSED IN 2.5 MINUTES?

    15SECOND COMBUSTION AIR INDUCER PREPURGEINITIATED BY CLOSED PROVE SWITCH.

    YES

    IGNITOR WARMUP 20 SECONDS.

    YES

    4SECOND TRIAL FOR IGNITION.GAS VALVE OPENS. IGNITOR ENERGIZED FOR 1 SECOND

    AFTER VALVE OPENS. BOARD 10M9301: IGNITORENERGIZED FULL 4 SECOND TRIAL.

    NO FLAME SENSED DURING THIS PERIOD.

    YES

    FLAME STABILIZATION PERIOD.

    GAS VALVE OFF. COMBUSTION AIR INDUCER ON.INDOOR BLOWER OFF.

    HAS CONTROL FAILED TO SENSE FLAME FORFIVE CONSECUTIVE TRIES DURING A SINGLE

    HEAT DEMAND?

    WATCHGUARD MODE. GAS VALVE OFF.COMBUSTION AIR INDUCER OFF.

    INDOOR BLOWER OFF WITH DELAYLEDs SIGNAL WATCHGUARD FAILURE CODE.

    IS 60MINUTE RESET PERIOD COMPLETE?

    YES

    4 SECONDS

    YES

    HAS CONTROL RESET IGNITIONSEQUENCE FOUR TIMES?

    FLAME SIGNAL ABOVE 0.2 MICROAMPS?

    YES

    YES

    YES

    ROLLOUT SWITCH CLOSED?

    GAS VALVE POWER OFF. COMBUSTION AIR INDUCER POWER ON.

    INDOOR BLOWER ONLED #1 ON. LED #2 SLOW FLASH.

    SEQUENCE HOLDS UNTIL ROLLOUT SWITCH IS RESETAND MAIN POWER IS INTERUPTED OR

    THERMOSTAT IS CYCLED OFF/ON FOR 1 TO 20 SEC.

    YES

    THERMOSTAT DEMAND SATISFIED.

    LED #1 & #2 SIMULTANEOUS SLOW FLASHES.

    COMB. AIR INDUCER CONTINUES 5SECONDPOST PURGE AFTER TSTAT DEMAND IS SATISFIED.

    INDOOR AIR BLOWER COMPLETES SELECTEDOFF" DELAY BEFORE SHUTTING OFF.

    YES

    NO

    5MINUTE PROVE SWITCHWATCHGUARD MODE.

    YES

    IS THERE A PROPER GROUND?

    IS VOLTAGE ABOVE 75 VOLTS?

    IS IGNITOR INTACT AND CONNECTED?

    LEDS SIGNALALTERNATINGFAST FLASH

    NO YES

    YESYES

    YES

    YES

    NO

    NO

    NO

    NO

    NO

    NO

    NO

    NO

    YES

    YES

    NO

    NO

    NO

    NO

    YES

    YES

    HAS PRIMARY SECONDARYLIMIT RESET (CLOSED)

    WITHIN 3 MINUTES?

    LIMIT SWITCHWATCHGUARD

    MODE. GAS VALVEOFF. COMB. AIR INDUCER OFF.

    INDOOR BLOWEROFF WITH DELAY.

    LED#1SLOWFLASH LED#2 ON.

    IS 60MINUTE RESET PERIOD

    COMPLETE?

    YES

  • Page 30

    COOLING SEQUENCE OF OPERATION

    NORMAL COOLING MODE ABNORMAL COOLING MODE

    IGNITION CONTROL MAIN POWER ON.

    CONTROL SELF DIAGNOSTIC CHECK.IS CONTROL OPERATING NORMALLY?

    YES

    SIGNAL POLARITY REVERSED AT LED.

    POWER ON

    GAS VALVE OFF. COMBUSTION AIR INDUCER OFF.INDOOR BLOWER OFF WITH NORMAL DELAY.

    SIGNAL CIRCUIT BOARD FAILURE AT LED.INTERRUPT MAIN POWER TO RESET CONTROL.

    YES

    IS POLARITY REVERSED?

    ROLLOUT SWITCH MONITORED CONTINUOUSLY.IS ROLLOUT SWITCH CLOSED?

    CHECK FOR MAIN BURNER FLAME SENSE.IS MAIN BURNER FLAME OFF?

    LED: SLOW FLASH RATE REMAINS UNCHANGEDTHROUGHOUT COOLING CYCLE.

    THERMOSTAT CALLS FOR COOLING.

    COMPRESSOR CONTACTOR AND SYSTEM FANENERGIZED WITH 0SECOND DELAY

    (COOLING SPEED). EACH TERM. ENERGIZED.

    COMPRESSOR OFF.

    THERMOSTAT OPENS.

    SYSTEM FAN AND ACC. TERM. OFFWITH 0SECOND DELAY.

    NO

    NO

    GAS VALVE OFF. COMBUSTION AIR INDUCER ON.INDOOR BLOWER ON.

    SIGNAL ROLLOUT SWITCH OPEN AT LED.SEQUENCE HOLDS UNTIL ROLLOUT SWITCH CLOSES.

    GAS VALVE OFF. COMBUSTION AIR INDUCER OFF.INDOOR BLOWER OFF WITH NORMAL DELAY.SIGNAL UNWANTED FLAME SENSED AT LED.

    SEQUENCE HOLDS UNTIL FLAME IS NOT SENSED.

    IS VOLTAGEABOVE 75 VOLTS?

    LED SIGNALS WAITING ON CALL FROMTHERMOSTAT. CONTROL WILL NOT RESPOND

    UNTIL VOLTAGE RISES ABOVE 75 VOLTS.

    YES

    YES

    YES

    NO

    NO

    NO

  • Page 31

    SURELIGHT CONTROLCONTINUOUS HEAT SPEED FAN SEQUENCE OF OPERATION

    LED: SLOW FLASH RATE REMAINSUNCHANGED THROUGHOUT SEQUENCE.

    MANUAL FAN SELECTION MADE AT THERMOSTAT.CONTROL (G) ENERGIZES SYSTEM FAN AT HEATH

    HEAT SPEED. EACH TERMINAL IS ENERGIZED.

    THERMOSTAT CALLS FOR HEAT (W).

    THERMOSTAT CALLS FOR COOLING.THERMOSTAT OPENS.

    SYSTEM FAN SWITCHED TO COOLH SPEED.EACH TERM. REMAINS ON.

    THERMOSTAT OPENS.

    CONTROL (G) ENERGIZES SYSTEM FAN AT HEATHHEAT SPEED. EACH TERM. ENERGIZED.

    NO YES

    YESNO

    HUMH TERM. ENERGIZES WITH COMB. AIR INDUCER.

    SYSTEM FAN REMAINS ON HEATHHEATING SPEED.

    SYSTEM FAN REMAINS ON HEATHHEATING SPEED.

    HUMH TERM. DEENERGIZES WITH COMB. AIR INDUCER

  • Page 32

    SURELIGHT TROUBLE SHOOTING GUIDE

    UPON INITIAL POWER UP, REMOVE ALL THERMOSTAT DEMANDS TO THE UNIT

    PROBLEM: 1 UNIT FAILS TO OPERATE IN THE COOLING, HEATING, OR CONTINUOUS FAN MODE

    Condition Possible Cause Corrective Action / Comments

    1.1

    Both diagnostic lights fail to lightup.

    1.1.1

    Main voltage 120V not supplied tounit.

    ACTION 1 Check 120V main voltage.Determine cause of main power failure.

    LED#1OffLED#2Off

    1.1.2

    Miswiring of furnace or improper connections.

    ACTION 1 Check for correct wiring of 120V topower make up box and transformer.

    ACTION 2 Check 24V wiring to control board.

    1.1.3

    Circuit breaker tripped or fails toclose.

    ACTION 1 Replace circuit breaker if it is resetbut does not have continuity.

    ACTION 2 If circuit breaker still trips, check forshort.

    1.1.4

    Door interlock switch failure.

    ACTION 1 Check that door switch is activatedwhen door is closed.

    ACTION 2 Check wire connections to switch,replace loose connectors.

    ACTION 3 Check continuity of switch in closedposition. Replace if defective.

    1.1.5

    Transformer Failure.

    ACTION 1 Check that transformer output is24V. Replace if defective.

    1.1.6

    Failed control board.

    ACTION 1 If all the above items have beenchecked, replace board.

    1.2

    Diagnostic lights flash the rollout

    code.

    1.2.1

    Rollout switch open.

    ACTION 1 Manually reset the rollout switchby pushing the top button.

    ACTION 2 Determine the cause of the rolloutswitch activation before leaving furnace.code.

    LED#1 O

    1.2.2

    Rollout switch failure.

    ACTION 1 Check continuity across rolloutswitch. Replace rollout switch if switch is reset

    but does not have continuity.

    LED#1On,

    LED#2Slow Flash1.2.3

    Mi i i i ti t ACTION 1 Check wiring connections to switchLED#2 Slow Flash

    Miswiring or improper connections atrollout switch.

    ACTION 1 Check wiring connections to switch.

    1.2.4

    Pin connector failure

    ACTION 1 Check pin connector for properconnection to control board.

    ACTION 2 Check continuity of the multi plugpin.

    1.3

    On initial powerup the comb. airblower does not energize.blower does not energize. Diagnostic lights flash the reversepolarity code.

    1.3.1

    120V main power polarity reversed.

    ACTION 1 Check the 120V has line and neutralcorrectly input into control.ACTION 2 Reverse the line and neutral at the120V field connection.

    LED#1Fast Flash,LED#2Slow Flash.

    120V field connection.

    1.4

    On initial power up the combustionair blower does not energize.

    Diagnostic lights flash normal power on operation.

    1.4.1

    Open combustion air blower motorcircuit.

    ACTION 1 Check for 120V to combustion airblower. If no power, check wire and connec

    tions.

    er on operation.

    LED#1Slow FlashLED#2Slow Flash

    1.4.2

    Failed combustion air blower motor.

    ACTION 1 If power is present at blower, replaceblower.

  • Page 33

    PROBLEM 1: UNIT FAILS TO OPERATE IN THE COOLING, HEATING, OR CONTINUOUS FAN MODE

    Condition Possible Cause Corrective Action / Comments

    1.5

    On initial powerup the combustionair blower remains energized.

    Di ti li ht fl h th i

    1.5.1

    Improper ground to the unit.

    ACTION 1 Check that the unit is properlyground.ACTION 2 Install a proper main ground to theunitg

    Diagnostic lights flash the impropermain ground.

    1.5.2

    6Pin connector is improperly attached to the circuit board.

    ACTION 1 Check 6pin connector for properinstallation. Correctly insert connector into control.

    LED#1Alternating Fast FlashLED#2Alternating Fast Flash

    1.5.3

    Line voltage is below 75V.

    ACTION 1 Check that the line voltage is above75V. Determine cause of voltage drop and supplycorrect voltage to the control.

    PROBLEM 2: UNIT FAILS TO OPERATE IN THE COOLING OR HEATING MODE, BUT COMBUSTIONAIR BLOWER OPERATES CONTINUOUS. UNITS WITH CONTROL BOARDS DATE CODED AFTER

    NOV. 1 1997, WILL OPERATE IN COOLING BUT NOT IN THE HEATING MODE, WITH COMBUSTIONAIR BLOWER CYCLING 5 SECONDS ON 55 SECONDS OFF.

    Condition Possible Cause Corrective Action / Comments

    2.1

    On initial powerup the combustionair blower remains energized. Diagnostic lights flash the impropermain ground. Units with control boards datecoded after Nov 1 1997; combustion

    2.1.1

    Open ignitor circuit.

    ACTION 1 Check for correct wiring and looseconnections in the ignitor circuit. Check multplug connections for correct installation.

    coded after Nov.1 1997; combustionair blower will cycle 5 seconds on 55seconds off.

    LED#1Alternating Fast FlashLED#2Alternating Fast Flash

    2.1.2

    Broken or failed ignitor.

    ACTION 1 Unplug ignitor and read resistanceacross ignitor. If resistance does not read between 10.9 and 19.7 ohms, replace the ignitor.

    PROBLEM 3: UNIT FAILS TO FIRE IN THE HEATING MODE, COMBUSTION AIR BLOWER DOESNOT ENERGIZE

    Condition Possible Cause Corrective Action / Comments

    3.1

    Unit operates with a cooling or continuous fan demand. Combustion air blower will not startwith a Heating demand. Diagnostic lights flash the limit failure

    d

    3.1.1

    Primary or secondary (if equipped )limit open.

    ACTION 1 Check continuity across switch(es).Switches reset automatically upon cool down.ACTION 2 Check for restrictions on blower inletair (including filter) and outlet air. Determinecause for limit activation before placing unit backin operation.

    g gmode.

    LED#1Slow Flash,LED#2On

    3.1.2

    Miswiring of furnace or improper connections at limit switch(es).

    ACTION 1 Check for correct wiring and looseconnections. Correct wiring and/or replace anyloose connections.

    3.2

    Unit operates with a cooling and continuous fan demand. Combustion air blower will not startwith a Heating demand. Diagnostic lights flash the pressure

    3.2.1

    Miswiring of furnace or improper connections to combustion air blower.

    ACTION 1 Check for correct wiring and looseconnections. Correct wiring and/or replace anyloose connections.

    Diagnostic lights flash the pressureswitch failure code.

    LED#1Off,LED#2Slow Flash

    3.2.2

    Pressure switch stuck closed.

    ACTION 1 Check that the pressure switch isopen without the combustion air blower operating. Replace if defective.

  • Page 34

    PROBLEM 3: UNIT FAILS TO FIRE IN THE HEATING MODE, COMBUSTION AIR BLOWER DOESNOT ENERGIZE (CONT.).

    Condition Possible Cause Corrective Action/Comments

    3.3

    Unit operates with a cooling and continuous fan demand. Combustion air blower will not startwith a Heating demand. Diagnostic lights flash the pressureswitch failure code 2 5 minutes after

    3.3.1

    Miswiring of furnace or improper connections to combustion air blower.

    ACTION 1 Check for correct wiring and looseconnections. Correct wiring and/or replace anyloose connections.

    switch failure code 2.5 minutes afterheating demand.

    LED#1Off, LED#2Slow Flash

    3.3.2

    Combustion air blower failure.

    ACTION 1 If there is 120V to combustion airblower and it does not operate, replace combustion air blower.

    PROBLEM 4: UNIT FAILS TO FIRE IN THE HEATING MODE, COMBUSTION AIR BLOWER ENERGIZES, IGNITOR IS NOT ENERGIZED.

    Condition Possible Cause Corrective Action/Comments

    4.1

    Unit operates with a cooling andcontinuous fan demand. Combustion air blower energizeswith a heating demand

    4.1.1

    Pressure switch does not close dueto incorrect routing of the pressure

    switch lines.

    ACTION 1 Check that the pressure switch linesare correctly routed. Correctly route pressureswitch lines.

    with a heating demand. Diagnostic lights flash the pressureswitch failure code 2.5 minutes afterheating demand.

    4.1.2

    Pressure switch does not close dueto obstructions in the pressure lines.

    ACTION 1 Remove any obstructions from thethe pressure lines and/or taps.

    g

    LED#1Off

    4.1.3

    Pressure switch lines damaged

    ACTION 1 Check pressure switch lines forleaks. Replace any broken lines.

    LED#1 OffLED#2Slow Flash 4.1.4

    Condensate in pressure switch line.

    ACTION 1 Check pressure switch lines for condensate. Remove condensate from lines. Checkthat the condensate lines are located correctly.

    4.1.5

    Pressure switch does not close dueto a low differential pressure across

    the pressure switch.

    ACTION 1 Check the differential pressure

    across the pressure switch. This pressure

    should exceed the set point listed on the

    switch.

    ACTION 2 Check for restricted inlet and ex

    haust vent. Remove all blockage.

    ACTION 3 Check for proper vent sizing and

    run length. See installation instructions.

    4.1.6

    Wrong pressure switch installed inthe unit, or pressure switch is out of

    calibration.

    ACTION 1 Check that the proper pressureswitch is installed in the unit. Replace pressureswitch if necessary.

    4.1.7

    Miswiring of furnace or improper connections at pressure switch.

    ACTION 1 Check for correct wiring and looseconnections. Correct wiring and/or replace anyloose connections.

    4.1.8

    Pressure switch failure.

    ACTION 1 If all the above modes of failure havebeen checked, the pressure switch may havefailed. Replace pressure switch and determine ifunit will operate.

  • Page 35

    PROBLEM 5: UNIT FAILS TO FIRE IN THE HEATING MODE, COMBUSTION AIR BLOWER ENERGIZES, IGNITOR IS ENERGIZED.

    Condition Possible Cause Corrective Action/Comments

    5.1

    Unit operates with a cooling and

    continuous fan demand.

    Combustion air blower energizes

    5.1.1

    Check that gas is being supplied tothe unit.

    ACTION 1 Check line pressure at the gas valve.Pressure should not exceed 13" WC for both natural and propane. Line pressure should read aminimum 4.5" WC for natural and 8.0"WC for propane.

    Combustion air blower energizes

    with Heating demand.

    Ignitor is energized but unit fails to

    light.

    5.1.2

    Miswiring of gas valve or loose connections at multipin control amp

    plugs or valve.

    ACTION 1 Check for correct wiring and looseconnections. Correct wiring and/or replace anyloose connections.

    LED#1Alternating Slow Flash

    LED#2Alternating Slow Flash

    5.1.3

    Defective gas valve or ignition control.

    ACTION 1 Check that 24V is supplied to the gasvalve approximately 35 seconds after heat demand is initiated.ACTION 2 Replace the valve if 24V is suppliedbut valve does not open.ACTION 3 Replace the control board if 24V isnot supplied to valve.

    PROBLEM 6: BURNERS LIGHT WITH A HEATING DEMAND BUT UNIT SHUTS DOWN PREMATURELY

    Condition Possible Cause Corrective Action/Comments

    6.1

    Burners fire with a heating demand. Burners light but unit shuts off prior

    6.1.1

    Wrong concentric vent kit used forterminating the unit.

    ACTION 1 Check vent termination kit installed.11/2" dia. concentric vent (kit60G77) for 50 and75 inputs and 2" dia. concentric vent (kit 33K97)for 100 &125 inputs.

    Burners light but unit shuts off priorto satisfying Tstat demand. Diagnostic lights flash the pressureswitch code.

    6.1.2

    Condensate drain line is not drainingproperly.

    ACTION 1 Check condensate line for propervent slope, and any blockage. Condensateshould flow freely during operation of furnace.Repair or replace any improperly installed condensate lines.

    LED#1OffLED#2Slow Flash

    6.1.3

    Low pressure differential at the pressure switch.

    ACTION 1 Check for restricted vent inlet or exhaust. Remove all blockage.ACTION 2: Check for proper vent sizing. Seeinstallation instructions.

    6.2

    Combustion air blower energizeswith a heating demand.

    B li ht b t f il t t lit

    6.2.1

    Sensor or sense wire is improperlyinstalled.

    ACTION 1 Check that sensor is properly located and that the sense wire is properly attached to both the sensor and the control.

    Burners light but fail to stay lit. After 5 tries the control diagnosticsflash the watchguard burners failed toignite code.

    6.2.2

    Sensor or sense wire is broken.

    ACTION 1 Check for a broken sensor.ACTION 2 Test continuity across the sensewire. If wire or sensor are damaged replace thecomponent.ignite code.

    LED#1Alternating Slow FlashLED#2Alternating Slow Flash

    6.2.3

    Sensor or sensor wire is grounded tothe unit.

    ACTION 1 Check for resistance between thesensor rod and the unit ground.ACTION 2 Check for resistance between thesensor wire and the unit ground.ACTION 3 Correct any shorts found in circuit.

    6.2.4

    Control does not sense flame.

    ACTION 1 Check the microamp signal fromthe burner flame. If the microamp signal is below 0.70 microamps, check the sense rod forproper location or contamination.ACTION 2 Replace, clean, or relocate flamesense rod. If rod is to be cleaned, use steelwool or replace sensor. DO NOT CLEAN RODWITH SAND PAPER. SAND PAPER WILLCONTRIBUTE TO THE CONTAMINATIONPROBLEM. NOTE: Do not attempt to bendsense rod.

  • Page 36

    PROBLEM 6: BURNERS LIGHT WITH HEATING DEMAND BUT UNIT SHUTS DOWN PREMATURELY (CONT.)

    Condition Possible Cause Corrective Action/Comments

    6.3

    Combustion air blower energizeswith a heating demand. Burners light. Rollout switch trips during theheating demand. Diagnostic lights flash rollout failure.

    6.3.1

    Unit is firing above 100% of thenameplate input.

    ACTION 1 Check that the manifold pressurematches value listed on nameplate. See installation instructions for proper procedure.ACTION 2 Verify that the installed orifice sizematch the size listed on the nameplate or installation instructions.ACTION 3 Check gas valve sensing hose to insure no leaks are present.ACTION 4 Check the input rate to verify ratematches value listed on nameplate.ure.

    LED#1OnLED#2Slow Flash

    6.3.2

    Gas orifices leak at the manifold connection.

    ACTION 1 Tighten orifice until leak is sealed.NOTE: Be careful not to strip orifice threads. ACTION 2 Check for gas leakage at the threadedorifice connection. Use approved method forleak detection (see unit instructions).

    6.3.3

    Air leakage at the connections between the primary heat exchanger,

    secondary heat exchanger, and combustion air blower.

    ACTION 1 Check for air leakage at all joints inthe heat exchanger assembly. Condition willcause high CO2 with high CO.ACTION 2 Seal leakage if possible, replaceheat exchanger if necessary, tag and return heatexchanger to proper Lennox personnel.

    6.3.4

    Insufficient flow through the heat exchanger caused by a sooted or re

    stricted heat exchanger.

    ACTION 1 Check for sooting deposits or otherrestrictions in the heat exchanger assembly.Clean assembly as outlined in instruction manual.ACTION 2 Check for proper combustion. Seetable 8 or 9 for proper CO2. CO should measurebelow .04% (400PPM) in an airfree sample offlue gases for either NG or LP.

    6.3.5

    Burners are not properly located inthe burner box.

    ACTION 1 Check that the burners are firing intothe center of the heat exchanger openings. Correct the location of the burners if necessary.

    6.4

    Combustion air blower energizeswith a heating demand. Burners light roughly and the unitfails to stay lit. Diagnostic lights flash watchguardflame failure.

    6.4.1

    Recirculation of flue gases. This condition causes rough ignitions and operation. Problem is characterized by

    nuisance flame failures.

    ACTION 1 Check for proper flow of exhaustgases away from intake vent. Remove any obstacles in front of the intake and exhaust ventwhich would cause recirculation.ACTION 2 Check for correct intake and exhaustvent installation. See instructions

    flame failure.

    LED#1Alternating Slow FlashLED#2Alternating Slow Flash

    6.4.2

    Improper burner crossovers

    ACTION 1 Remove burner and inspect thecrossovers for burrs, or any restriction or ifcrossover is warped. Remove restriction or replace burners.

  • Page 37

    PROBLEM 6: BURNERS LIGHT WITH HEATING DEMAND BUT UNIT SHUTS DOWN PREMATURELY (CONT.)

    6.5

    Combustion air blower energizeswith a heating demand. Burners light. Diagnostic lights flash watch guardflame failure. NOTE" Unit might go into 60 minute Watchguard mode depending onintermittent nature of sensor signal.

    LED#1Alternating Slow FlashLED#2Alternating Slow Flash

    6.5.1

    Loose sensor wire connection causesintermittent loss of flame signal.

    ACTION 1 Check that the sensor is properly located.ACTION 2 Check that the sense wire is properly attached to both the sensor and the control.Pay extra attention to the pin connectors.

    PROBLEM 7: CONTROL SIGNALS LOW FLAME SENSE DURING HEATING MODE

    Condition Possible Cause Corrective Action/Comments

    7.0

    Unit operates correctly but thediagnostic lights flash low flamesense code

    7.1.1

    Sense rod is improperly located onthe burner.

    ACTION 1 Check the sense rod for proper location on the burner. Properly locate the sense rodor replace if rod cannot be located correctly.

    sense code.

    LED#1Slow FlashLED#2Fast Flash

    7.1.2

    Sense rod is contaminated.

    ACTION 1 Check sense rod for contaminationor coated surface. Clean the sense rod with steelwool or replace sensor. DO NOT USE SAND PAPER TO CLEAN ROD. SAND PAPER WILLCONTRIBUTE TO THE CONTAMINATIONPROBLEM.

    PROBLEM 8: INDOOR BLOWER FAILS TO OPERATE IN COOLING, HEATING, OR CONTINUOUSFAN MODE

    Condition Possible Cause Corrective Action/Comments

    8.0

    Indoor blower fails to operate incontinuous fan, cooling, or heatingmode.

    8.1.1

    Miswiring of furnace or improper connections at control or indoor blower

    motor.

    ACTION 1 Correct wiring and/or replace anyloose connections. Check for correct wiring andloose connections.

    8.1.2

    120V is not being supplied to the indoor air blower or blower motor fail

    ure.

    ACTION 1 Check for 120V at the various callsfor indoor blower by energizing "Y", "G", and "W"individually on the low voltage terminal strip.Note that when "W is energized, the blower isdelayed 45 seconds. If there is 120V to each motor tap but the blower does not operate, replacethe motor.

    8.1.3

    Defective control board

    ACTION 1 If there is not 120V when "Y", "G", or"W" is energized, replace the control.

    PROBLEM 9: RF STATIC DURING TIME FOR IGNITION

    Condition Possible Cause Corrective Action/Comments

    9.0

    AM radio interference.

    9.1.2

    Ignitor operationACTION 1 Call Technical Support, Dallas.

  • Page 38

    TABLE 8

    80% EFFICIENCY MODELS

    CO2 AT *STEADY STATE OPERATION

    UNIT NATURAL PROPANE

    G23(X) 6.5% 8.5% 8.0% 9.5%

    G24M 6.0% 8.0% 6.5% 8.5%

    80MGF 6.0% 8.0% 6.5% 8.5%

    80UHG 6.0% 8.0% 6.5% 8.5%

    **G27M 6.0% 8.5% N/A

    G40/50UH (X)24A45 4.5% 6.5% 5.8% 7.8%

    G40/50UH(X)36A070 5.8% 7.8% 6.8% 7.8%

    G40/50UH(X)36B0906 2% 8 2% 6 7% 8 6%

    G40/50UH(X)48B0906.2% 8.2% 6.7% 8.6%

    G40/50UH(X)48C110 5.9% 7.9% 7.5% 9.5%

    * Furnace firing at least 15 minutes.

    ** Furnace firing on high fire.

    TABLE 9

    90% EFFICIENCY MODELS

    CO2 AT *STEADY STATE OPERATION

    UNITMIN VENT MAX VENT

    UNITNATURAL PROPANE NATURAL PROPANE

    G26 6.0% 8.0% 7.0% 9.0% 6.0% 8.0% 7.0% 9.0%

    GHR26 6.0% 8.0% 7.0% 9.0% 6.0% 8.0% 7.0% 9.0%

    90UGF 6.0% 8.0% 7.0% 9.0% 6.0% 8.0% 7.0% 9.0%

    **G32Q/V 6.9% 8.4% 7.5%9.0% 7.3% 8.8% 8.2%9.5%

    **GHR32Q/V 6.0% 8.0% 7.0% 9.0% 6.0% 8.0% 7.0% 9.0%

    * Furnace firing at least 15 minutes.

    ** Furnace firing on high fire.

  • Page 39

    SERVICE NOTES

    SureLight Ignition SystemDiagnostic Code TableBoard Terminal DesignationsOperationWiring Diagrams and Sequence of OperationFlow ChartTroubleshooting