T H E S T R E N G T H W I T H I N
SUSPENDED CEI LING SYSTEMS
MONTREAL TORONTO CALGARY EDMONTON VANCOUVER
8/10/2019 Suspended Ceiling System
2/12
S U S P E N D E D C E I L I N G S Y S T E M S
Bailey Metal Products Limited offers a complete range
of Suspended Ceiling Systems and Accessories for all your
building needs. With offices across the country, Bailey is the
leading manufacturer and supplier of a complete range of
wall and ceiling systems.
The comprehensive design of the Bailey Suspended Ceiling
Systems will accommodate all your ceiling installation require-
ments. These systems, manufactured in aluminum or steel,meet all ULC fire rating requirements. They are versati le and
easy to install.
Bailey Suspended Ceiling Systems incorporate features
such as superior strength, design flexibility, environmental
protection and multiple colour and profile choices for appealing
aesthetics. With easy installation and the wide variety of
products, sizes and accessories, Bailey is your best choice for
suspended ceilings.
Bailey Metal Products Limited has a reputation for
exceptional customer service and is proud to offer quality
building products through our plants across Canada for over
50 years. Should you have any questions about our ceiling
systems, or any other Bailey products please contact the officenear you. Thank you.
EXPOSED SYSTEMS
Lance-Lock System 1800 15/16 Exposed Tee System - Fire-Rated Page 3
Lance-Lock System 900
15/16 Exposed Tee System - Non-Rated Page 4
Shadowline System 800 9/16 Exposed Tee System - Non-Rated Page 5
Lance-Lock System 400 All Aluminum Exposed Tee System Page 6
ENVIRONMENTAL SYSTEMS
Lance-Lock 1400 15/16 Rated System Page 7
Lance-Lock 700 15/16 Class A System Page 7
Lance-Lock 600 916 Class A System Page 7
Accessories and Conversion Chart Page 8
Lance-Lock Punching Detailsand Relocatable System Page 9
Colours and Finishes Page 10
Bailey System Layouts Page 11
Specifications and Installation Requirements Page 12
Bailey offers a wide range of easy to install, low maintenance
and attractive suspended ceiling systems for all applications.
TABLE OF CONTENTS
8/10/2019 Suspended Ceiling System
3/12
L A N C E - L O C K S Y S T E M S
BAILEY LANCE-LOCK SYSTEM 1800 15/16 EXPOSED TEE SYSTEM FIRE-RATED
Bailey Lance-Lock System 1800 exposed tee fire-rated system
has been fully fire tested at Underwriters Laboratories of Canada
(ULC), UL in the U.S.A., and Warrington Fire Research Centrein the United Kingdom. The fire-rated main tee incorporates the
Bailey Patented Expansion Joint. Under fire conditions, this in-line
expansion joint expands linearly reducing the rotation effect on
the grid itself.
Baileys ULC fire-rating listings cover all building applications through
their 1 and 2 hour floor/ceiling and 1 hour roof/ceiling designs.
All fire-rated cross tees are of 1 1/2 high structural design with
fire-rated end joinery designed to expand through the main tee
slot under fire conditions.
In addition to meeting fire rating requirements, Bailey Lance-Lock
System 1800 delivers all installation, economy and durability
featured in the non-rated System 900.
U.L.C. Classified for fire resistance designs
Straight push-in joinery with stepped edge
for a crisp, clean main tee/cross tee intersection
ASTM C635 Intermediate Duty Rating
Rapid assembly for economical installation
Engineered for maximum design flexibility
with economy and durability
ADVANTAGES
15/16
1 1/2
1 1/2
15/16
15/16
8/10/2019 Suspended Ceiling System
4/12
L A N C E - L O C K S Y S T E M S
BAILEY LANCE-LOCK SYSTEM 900 15/16 EXPOSED TEE SYSTEM NON-RATED
Bailey Lance-Lock System 900 exposed tee non-rated system
is a fully engineered, double web design. The main runners are
1 1/2 (38mm) high, available from stock in 10 (3000mm) and
12 (3600mm) lengths. Custom lengths up to 12 can easily be
manufactured and all main runners are available with either
conventional or basketweave end joinery.
The 1 standard and 1 1/2 structural cross tees have a straight
push-in locking design facilitating ease of installation and
removal. All cross tees are designed with a toboggan or
stepped end ensuring a crisp, clean appearance.
Engineered and tested to ASTM C635
Intermediate and Heavy Duty Standards
Designed for installation in either conventional
or basketweave layouts
Straight push-in joinery with stepped edge
for a crisp, clean main tee/cross tee intersection
Sturdy double web design
Rapid assembly or disassembly for ease
of installation or removal for relocation
Engineered for maximum design
flexibility with economy and durability
ADVANTAGES
15/16
15/16
1 1/2
15/16
1
8/10/2019 Suspended Ceiling System
5/12
S H A D O W L I N E S Y S T E M S
SHADOWLINE SYSTEM 800 9/16 EXPOSED TEE SYSTEM NON-RATED
Shadowline System 800 9/16 narrow face exposed grid
system enhances the look of the ceiling by decreasing the
visibility of the suspension systems.
The Bailey Shadowline Suspended Ceiling System is a Class A
non-rated system. This system combines the engineered strength
of the Bailey Lance-Lock system, with the sleek look provided by
narrower exposed face.
In addition, Shadowline System 800 incorporates the Bailey
panel centering device, ensuring panels are always centered.
this feature adds rigidity to both main and cross tees.
Main tees are available in 10 and 12 lengths to meet any
layout demands. Custom lengths up to 144 are available by
special order.
All products use a 1 1/2 body for added strength
Double web design body
Straight push-in joinery with stepped edge for a
crisp, clean main tea/cross tee intersection
Engineered with the Bailey panel centering device
for rigidity and precise panel location
Rapid economical installation
Hanger holes in grid bulb and body for complete
installation flexibility
Finished in Tile White, an ideal match for today's
ceiling panels.
ADVANTAGES
9/16
9/16
1 1/2
9/16
1 1/2
8/10/2019 Suspended Ceiling System
6/12
L A N C E - L O C K S Y S T E M S
BAILEY LANCE-LOCK SYSTEM 400 15/16 ALL ALUMINUM EXPOSED TEE SYSTEM
Bailey Lance-Lock System 400 15/16 Exposed Grid system is
manufactured from 100% aluminum, providing maximum
protection in higher humidity environments.
Available in white or natural aluminum finish, Bailey Lance-Lock
System 400 offers the versatility of conventional design. This allaluminum system meets the requirements of areas such as kitchens,
food processing operations, etc.
Main tees are available in 10 and 12 lengths to meet any layout
demands.
Cross tees are available in standard lengths of 1, 2, 4, and 5.
All products use a 1 1/2 body for added strength
Double web design body
Straight push-in joinery with stepped edge for
a crisp, clean main tee/cross tee intersection
White or natural aluminum finish design
Rapid economical installation
Hanger holes in grid bulb and body for complete
installation flexibility
Designed to provide maximum corrosion resistance
ADVANTAGES
15/16
15/16
1 1/2
15/16
1 1/2
8/10/2019 Suspended Ceiling System
7/12
L A N C E - L O C K E N V I R O N M E N T A L S Y S T E M S
BAILEY LANCE-LOCK SYSTEM 700 15/16 CLASS A SYSTEM
BAILEY LANCE-LOCK SYSTEM 1400 15/16 FIRE-RATED SYSTEM
BAILEY LANCE-LOCK SYSTEM 600 9/16 CLASS A SYSTEM
Lance-Lock 700 is designed for installationin hostile environments, where the ceiling
will be subjected to high humidity.
Lance-Lock 700 is manufactured fromhot dipped galvanized steel to provide
maximum protection in areas such as food
process plants, kitchens and health care
centers where regular washing of the
ceiling may be required.
At the same time, Lance-Lock 700incorporates the features and benefits
of the Lance-Lock 900 system, including
superior strength, ease of installation
and design flexibility.
Lance-Lock 1400 system not only suitsthe design needs of hostile environments,
but is also classified for ULC Fire Resistance
Designs.
As with Lance-Lock 700, hot dipped
galvanized steel provides the environmental
protection you need, while meeting your
ULC fire rating requirements at the same
time.
Lance-Lock 600 offers the same designfeatures and benefits as the 700 system,in a 9/16 profile.
Manufactured from hot dipped galvanized
steel, Lance-Lock 600 provides environ-mental protection with the aesthetics of
narrow grid in one system.
Hot dipped galvanized steel
For Installation in high
humidity environments
Double web design body
Heavy and intermediate Duty
ASTAM C635 classifications
Available in all standard
colours
ADVANTAGES
Provides a ULC Fire Rated
Environmental System
Heavy and Intermediate
ASTM C635 classification
Double web, hot dipped
galvanized components
Lance-Lock straight lock-in
end joinery
ADVANTAGES
1 1/2 double web design
Narrow grid design
Hot dipped galvanized steel
Designed for protection in
hostile environments
ADVANTAGES
15/16
1 1/2
15/16
1
15/16
1 1/2
15/16
1 1/2
9/16
1 1/2
9/16
1 1/2
8/10/2019 Suspended Ceiling System
8/12
Dimension
Variable
Angle Mould BMF F Mould BMX32 Flex Wall MouldBMX32 Flex Wall Mould
1/2 or 5/8 Board
AFS-10
Panel/Tile Width/Length
12 x 12 = 300mm x 300mm
12 x 24 = 300mm x 600mm
24 x 24 = 600mm x 600mm
24 x 48 = 600mm x 1200mm
24 x 60 = 600mm x 1500mm
20 x 60 = 500mm x 1500mm
30 x 60 = 750mm x 1500mm
Grid Width/Length
9/16 = 14mm
15/16 = 24mm
1 = 300mm
2 = 600mm
4 = 1200mm
5 = 1500mm
8 = 2400mm
10 = 3000mm
12 = 3600mm
1/2 = 13mm
5/8 = 16mm
3/4 = 19mm
1 = 25mm
.012 = .31mm
.015 = .38mm
.018 = .46mm
.020 = .51mm
.033 = .84mm
10.76 sq.ft. = 1 sq. metre
2.205 lbs = 1kg
3.94 = 100mm
Panel/Tile Thickness Imperial/Metric Conversion
L A N C E - L O C K S U S P E N D E D C E I L I N G A C C E S S O R I E S
BAILEY WALL ANGLES
BAILEY COLUMN RINGS
CORNER CAPS
BAILEY ARCHITECTURAL FLAT STRAP
MISCELLANEOUS
Bailey flat strap is available in various
widths and finishes to match your ceilingor custom colour requirements.
Architectural flat straps are ideal for curved
and illuminated kitchen type ceilings.-10 lengths.
BA 21 Hold Down ClipFor use with 1 1/2 ceiling grid over
5/8, 1/2, 3/4 panels to resist
upward wind loading on tiles.
BA 53 installation ClampA multipurpose clamp, often used to hold
your line to the wall angle when laying
out and levelling your ceiling.
Paired Tee ClipProvides a simple method of introducing
a double main tee into your ceiling system.
The space between the double main tees
allows for air return or air handling
through linear diffusers.
Available for both square
or round (bullnose) corners.
Available in steel or aluminum with baked enamel
paint finish to match the grid. Custom made to specific
dimensions. Post painted to match any design.
Bailey provides a wide variety
of mouldings produced in
steel, offering various colours
and finishes to meet most
design needs.
METRIC MODULE CONVERSION CHART (All dimensions indicate nominal size)
Product NumberOpening
DimensionCenter to Center
Dimension
B134 1 3/4 3/4
B200 2 1
B214 2 1/4 1 1/4
B212 2 1/2 1 1/2
B300 3 2
3/4
3/4
1/2
Conventional Reveal
BA 35 BA 36 BA 37 Bullnose
3/4 1 3/4
PAIRED TEE
CLIP
Main RunnerOpening
8/10/2019 Suspended Ceiling System
9/12
3 6 6 3
75mm
BSC-3 Clip
Main Runners
Locating Lance
1 1/2 Cross Tee
L A N C E - L O C K S Y S T E M D E T A I L S
The Bailey Relocatable Clip is designed to allow a cross tee
to main tee connection within non-compatible systems and non-
modular layouts.
Existing ceilings may be changed or added to using Bailey grid,
irrespective of the original ceiling system. In ceilings requiring
the installation of custom size fixtures, diffusers, speakers, etc.,
additional cross tees can easily be locked in place, even after
ceiling completion.
Standard BSC-3 Clip Installation
NOTE: Stocked cross tees less than 48 (1200mm) long are produced without holes. Custom punching to suit any layout is easily accommodated.
Lance-Lock System 900 = Be Non-Rated Assemblies Lance-Lock System 1800 = Bef Fire-Rated Assemblies
Location and Locking Lances Removed
BSC-3
BAILEY LANCE-LOCK IMPERIAL/METRIC PUNCHING DETAILS
BAILEY RELOCATABLE CLIP/REMOVABLE CROSS TEE SYSTEM
MAIN RUNNERS Web Height 1 1/2 (38mm)
CROSS TEES Web Height 1 (25mm)
75mm 150mm 150mm
Be/Bef 144 24 Slots @ 6 o.c. Be/Bef 3600 24 Slots @ 150mm o.c
5 10 10 5
125mm 250mm 250mm 125mmBe 120 12 Slots @ 10 o.c. Be 3000 12 Slots @ 250mm o.c
12 12 12 12
300mm 300mm 300mm 300mm
Be 48 3 Slots as shown Be 1200 3 Slots as shown
12 12
300mm 300mm
Be 24 1 Slot @ mid-point Be 600 1 Slot @ mid-point
CROSS TEES Web Height 1 1/2 (38mm)
20 20 20 20
500mm 500mm 500mm
20 20
500mm 500mm 500mm
Bef 120 5 Slots @ 20 o.c. Bef 3000 5 Slots @ 500mm o.c.
6 14 10 6
150mm 350mm 250mm
10 14
250mm 350mm 150mm
Bef 60 5 Slots as shown Bef 1500 5 Slots as shown
12 12 12 12
300mm 300mm 300mm 300mm
Bef 48 3 Slots as shown Bef 1200 3 Slots as shown
12 12
300mm 300mm
Bef 24 1 Slot @ mid-point Bef 600 1 Slot @ mid-point
8/10/2019 Suspended Ceiling System
10/12
C O L O U R A N D F I N I S H E S
THE BAILEY COLOUR GUIDE
THE BAILEY COLOUR GUIDE
The Baileys Lance-Lock System introduces a collection of colours
designed to compliment current interiors and those of the future.
From standard white to metallic finishes, Bailey offers a full
colour spectrum.
Baileys Lance-Lock series are available in these standard colours.
Ask your dealer or sales representative for information on any
custom colours you may require.
*For special colours, please consult your sales representativeNOTE: The colours shown have been reproduced with all the fidelity possible with commercial printing processes. A specific colour may appear different from one class of
product to another. For assurance, ask for an actual sample to see the true colour of the product you select.
STANDARD
METALLICS
White Black Platinum Parchment Haze Manilla Sandstone Taupe
Chrome Brass Aluminum
8/10/2019 Suspended Ceiling System
11/12
CONVENTIONAL LAYOUT. BASKETWEAVE LAYOUT
(System utilizing 120 cross tees as main memberS)
5 x 5 or 1500mm x 1500mm Module
20 X 60 or 500mm x 1500mm Sub-Module
5 x 5 or 1500mm x 1500mm Module
20 X 60 or 500mm x 1500mm Sub-Module
4 x 4 or 1200mm x 1200mm Module
2 x 2 or 600mm x 600mm Sub-Module
4 x 4 or 1200mm x 1200mm Module
2 x 4 or 600mm x 1200mm Sub-Module
600 60075
NOTE: For fixture loads with specified material thickness, hanger spacing and selected cross tee height, please contact Bailey Metal Products Limited for allowable loads
for your specific application.
NOTES:
MT = 1 1/2 Main Tee 12 Foot (3600mm)
CT = 1 or 1 1/2 Cross Tee 48 Inch (1200mm)
NOTES
MT = 1 1/2 Main Tee 12 Foot (3600mm)
CT1 = 1 or 1 1/2 Cross Tee 48 Inch (1200mm)
CT2 = 1 or 1 1/2 Cross Tee 24 Inch (600mm)
24 243
1200
Fixture Location
Where Crossed
Splice Location
Typical
Hanger Location
Typical
Fixtures @ 8 - 0 O.C.
Fixtures @ 6 - 0 O.C.
4-
0
600
600
Hanger Location
Typical
600 60075Splice Location
Typical
24
24
24 243
Fixture Location
Where Crossed
15 20205375 500500125
Splice Location
Typical
1500
5-
0
Fixture Location
Where Crossed
NOTES:
MT = 1 1/2 Main Tee 10 Foot (3 metre)
CT = 1 1/2 Cross Tee 60 Inch (1500mm)
NOTES:
CT 1 = 1 1/2 Cross Tee 120 Inch (3000mm)
CT 2 = 1 1/2 Cross Tee 60 Inch (1500mm)
5-
0
1500
= 1500
3 @ 500
= 5 - 0
3 @ 20Fixture Location
Where Crossed
Hanger
Location
Typical
Any Fixture
May Be
Absent or
Rotated 90
Without
Requiring
Additional
Hangers
Any Fixture
May Be Absent
B A I L E Y S Y S T E M L A YO U T S
CONVENTIONAL LAYOUT. CONVENTIONAL LAYOUT.
Splice Location
Typical
Any Fixture
May Be Absent
Any Fixture
May Be Absent
Any Fixture
May Be Absent
8/10/2019 Suspended Ceiling System
12/12
MONTREALLES PRODUITS METALLIQUES BAILEY LTEE
525 Avenue Edward VIIDorval QC H9P 1E7Tel: (514) 735 3455
(800) 263 3455
F (514) 735 5052
TORONTO
One Caldari RoadConcord ON L4K 3Z9Tel: (905) 738 9267
(800) 668 2154Fax: (905) 738 5712
BAILEY METAL PRODUCTS LIMITED
CALGARY
3924 27th Street NECalgary AB T1Y 5K7Tel: (403) 248 3536
(800) 665 2013Fax: (403) 248 0288
EDMONTON
5710 Roper Road N.W., Suite 101Edmonton AB T6B 3G7
Tel: (780) 462 5757(800) 563 1751
Fax: (780) 465 3791
CODES AND S TANDARDS (A r ch i t e c t u ra l Spec i f i ca t i on s )
Characteristics, properties or performance of materials or
systems manufactured by Bailey Metal Products Limited
herein described are derived from data obtained under
controlled test conditions. Bailey makes no warranties,
express or implied, as to their characteristics, properties or
performance under any variations from such conditions in
actual construction. Bailey Metal Products Limited assumes
no responsibility for the effects of structural movement.
NOTICE: The Information in this document is subject tochange without notice. Bailey assumes no responsibility
for any errors that may appear in this document.
See Bailey Acoustical Ceiling Systems literature
for product details, recommended uses and
application instructions.
VANCOUVER
7715 Anvil WaySurrey BC V3W 6A2Tel: (604) 590 5100
(800) 818 2666Fax: (604) 599 5371 4
874-0709-2500
CODES AND STANDARDS
The Bailey exposed grid suspended
ceiling systems are manufactured
to the following standards:
ASTM C635
Grade of Steel:
ASTM A 366/A 366M or better
Steel Coating: ASTM C635 or better
LANCE-LOCK FIRE RESISTANCE RATINGS
Canada
Lance-Lock is fire-rated for the requirementsof both 1 and 2 hour roof/ceiling and
floor/ceiling designs. All testing was carried
out at Underwriters Laboratories of Canada
(ULC) in accordance with CAN 4 S101M
Guide Item 40U 18.18.
ULC Time Rated Designs
C 204, D 203, D 205, G 208, G 218, I 210,
I 211, I 214, I 215, L 201, R 222, R 224.
United States
Bailey is UL Classified for the requirements
of both 1 and 2 hour roof/ceiling and
floor/ceiling fire rated designs. All testing
was conducted in accordance with
ANSI/UL 263 (ASTM E 119 AND NFPA 251).
Please contact our office for specific
design numbers.
United Kingdom
All fire testing was completed at theWarrington Fire Research Center. The
Bailey Lance-Lock System is fire-rated for
1 hour as required under British Standard
476 Part 23 1987.
Metric Installations:
All components are manufactured in
both Metric and Imperial as referenced.
ARCHITECTURAL SPECIFICATIONS
1. General:
The 15/16, 9/16 exposed grid
suspension systems are manufactured
by Bailey Metal Products Limited.
2. Materials:
2.1 Lance-Lock System.
The 15/16 (Fire-Rated), double-web
design, Lance-Lock Exposed Grid System,
shall conform to the requirements of the
Intermediate Duty and Heavy Duty
classification of ASTM C635.
2.2 Shadowline System.
9/16 Shadowline Exposed Grid System
of double-web design, incorporates the
Bailey tile-centering device.
2.3 All materials are cold rolled steel
with protective coating to ASTM C635,
or better. Pre-painted baked-on capping
Global White Tile.
3. Installation:
3.1 The Bailey Exposed Grid Suspension
System shall be installed in accordance
with the requirements of ASTM C636.
Deflection of any component shall not
exceed 1/360 of the span.
3.2 Main Runners to be installed 24, 36
48, or 60 on centre or as specified on
drawings, and directly suspended by wire
not less than 12 gauge in thickness.
Suspension wire to be spaced at 48 or
60 on centre as required.
3.3 Cross Tees to be interconnected tomain runners at 20, 24, 36, 48, or 60
on centre, or as required.
3.4 Wall mouldings (BM5 Angle), (BMR10
Reveal Mould) to be installed wherever
ceiling meets vertical surfaces.
3.5 Install supplemental hangers where
the weight of light fixtures or other ceiling
apparatus, cause the deflection of the
ceiling grid to exceed 1/360, as specified
in ASTM C636.
NOTE: All hanger wire to be tightly
wrapped with a minimum of three
full turns.