Sustainable Energy Action Plan 2011-2020
Cluj-Napoca, Romania
December 2012
City of Cluj-Napoca
Sustainable Energy Action Plan 2011-2020 Cluj-Napoca
i
Acknowledgment
This document was developed with the support and contribution of several experts
within the local and regional administration as well as certain private and state
companies. We would like to thank all who contributed and supplied data for this
Sustainable Energy Action Plan.
Sustainable Energy Action Plan 2011-2020 Cluj-Napoca
ii
1. Executive Summary .................................................................................................................... 1
2. SEAP - Introduction and Requirements ..................................................................................... 1
2.1. What is a SEAP ...................................................................................................................... 1
2.2. Scope of the SEAP ................................................................................................................ 1
2.3. Time horizon........................................................................................................................... 2
3. Methodology ............................................................................................................................... 3
4. General Strategy ........................................................................................................................ 3
4.1. Objectives and targets ........................................................................................................... 3
4.1.1. CO2 emissions reduction target and time horizon ............................................................. 3
4.1.2. Scope ................................................................................................................................. 3
4.2. Vision for the future ................................................................................................................ 3
4.3. Presentation of Cluj-Napoca .................................................................................................. 3
4.3.1. General information ........................................................................................................... 4
4.3.2. Municipal buildings and facilities ........................................................................................ 5
4.3.3. Supply and disposal ........................................................................................................... 5
4.3.4. Mobility ............................................................................................................................... 8
4.3.5. Internal organisation ........................................................................................................ 10
4.3.6. Communication channels ................................................................................................ 12
4.4. Financial aspects and monitoring......................................................................................... 12
4.4.1. Financial sources ............................................................................................................. 12
4.4.2. Monitoring ........................................................................................................................ 12
5. Baseline Emission Inventory .................................................................................................... 13
5.1. Final energy consumption .................................................................................................... 13
5.2. CO2 emissions ..................................................................................................................... 13
5.2.1. Local electricity generation and related CO2 emissions.................................................. 14
5.2.2. Local urban heating and corresponding emissions ......................................................... 14
6. Planned Actions and Measures until 2020 ............................................................................... 15
6.1. Buildings, Equipment and Facilities ..................................................................................... 16
6.2. Transport .............................................................................................................................. 18
6.3. Local electricity production ................................................................................................... 20
6.4. Local heating and cooling .................................................................................................... 21
6.5. Land use planning ................................................................................................................ 22
6.6. Public procurement .............................................................................................................. 22
6.7. Working with citizens and stakeholders ............................................................................... 23
6.8. Internal organisation ............................................................................................................. 24
Appendix ................................................................................................................................................ 25
Appendix 1 - SEAP committee........................................................................................................... 26
Appendix 2 - Letter of Recognition (European Energy Award) .......................................................... 28
Sustainable Energy Action Plan 2011-2020 Cluj-Napoca
1
1. Executive Summary
In recent years, energy efficiency, mobility and climate considerations have gained
substantial importance in the municipality of Cluj-Napoca, as confirmed by the Cluj-
Napoca Mayor signing the Covenant of Mayors in 2011.
The municipality aims to reduce its CO2 emissions by at least 20% by 2020,
compared to 2011 levels. This Sustainable Energy Action Plan (SEAP) sets out the
measures with which this objective is to be reached. The objective is very ambitious;
however, implementing more than 60 measures in various areas will allow CO2
emissions to be reduced by around 22% and end-use energy to be reduced by
around 20%. Additionally, the portion of renewable sources of energy will increase by
almost 8% over the same period. The costs of implementing the planned measures in
the municipality are around EUR180 million.
2. SEAP - Introduction and Requirements1
2.1. What is a SEAP
The Sustainable Energy Action Plan (SEAP) is a key document that shows how the
Covenant signatory will reach its commitment by 2020. It uses the results of the
Baseline Emission Inventory to identify the best fields of action and opportunities for
reaching the local authority’s CO2 reduction target. It defines concrete reduction
measures, together with time frames and assigned responsibilities, which translate
the long-term strategy into action. Signatories commit themselves to submitting their
SEAPs within the year following adhesion.
The SEAP should not be regarded as a fixed and rigid document, as circumstances
change, and, as the ongoing actions provide results and experience, it may be
useful/necessary to revise the plan on a regular basis.
2.2. Scope of the SEAP
The Covenant of Mayors concerns action at local level within the competence of the
local authority. The SEAP should concentrate on measures aimed at reducing the
CO2 emissions and final energy consumption by end users. The Covenant’s
commitments cover the whole geographical area of the local authority (town, city,
region). Therefore the SEAP should include actions concerning both the public and
1 European Union (2010): “How to develop a Sustainable Energy Action Plan”. Chapter 1.
Sustainable Energy Action Plan 2011-2020 Cluj-Napoca
2
private sectors. However, the local authority is expected to play an exemplary role
and therefore to take outstanding measures related to the local authority’s own
buildings and facilities, vehicle fleet, etc. The local authority can decide to set the
overall CO2 emission reduction target either as ‘absolute reduction’ or ‘per capita
reduction’.
The main target sectors are buildings, equipment/facilities and urban transport. The
SEAP may also include actions related to local electricity production (development of
PV, wind power, CHP, improvement of local power generation), and local
heating/cooling generation. In addition, the SEAP should cover areas where local
authorities can influence energy consumption in the long term (as land use planning),
encourage markets for energy efficient products and services (public procurement),
as well as changes in consumption patterns (working with stakeholders and citizens).
The industrial sector, in contrast, is not a key target of the Covenant of Mayors, so
the local authority may choose to include actions in this sector or not. In any case,
plants covered by the ETS (European CO2 Emission Trading Scheme) should be
excluded, unless they were included in previous plans of the local authority.
2.3. Time horizon
The time horizon of the Covenant of Mayors is 2020. Therefore, the SEAP has to
contain a clear outline of the strategic actions that the local authority intends to take
in order to reach its commitments by 2020. The SEAP may cover a longer period, but
in this case it should contain intermediate values and objectives for the year 2020.
As it is not always possible to plan in detail concrete measures and budgets for such
a long time span, the local authority may distinguish between:
- a vision, with a long-term strategy and goals until 2020, including firm
commitments in areas like land-use planning, transport and mobility, public
procurement, standards for new/renovated buildings etc.;
- detailed measures for the next 3-5 years which translate the long-term strategy
and goals into actions.
It is also strongly suggested that measures related to the local authority’s own
buildings and facilities are implemented first, in order to set an example and motivate
stakeholders.
Sustainable Energy Action Plan 2011-2020 Cluj-Napoca
3
3. Methodology
The methodology used to develop the SEAP is the one recommended in the Guide
“How to develop an Sustainable Energy Action Plan“, developed by the European
Commission through the Joint Research Centre (JRC), the Institute for Energy and
the Institute for Environment and Sustainability (IES).
4. General Strategy
4.1. Objectives and targets
4.1.1. CO2 emissions reduction target and time horizon
The city of Cluj-Napoca intends to achieve a reduction in CO2 emissions of 20% by
2020 compared to 2011 levels. The target is set as an absolute target (not per
capita), since total population is not expected to change significantly until 2020.
4.1.2. Scope
This Sustainable Energy Action Plan of Cluj-Napoca focuses on the following areas
of intervention
- Buildings, equipment/facilities
- E-administration
- Transport
- Local electricity production
- Local heating/cooling
- Land use planning
- Public procurement
- Working with citizens and stakeholders (communication and cooperation)
- Internal organisation
4.2. Vision for the future
Cluj-Napoca is a regional centre for innovation and opportunities, an attractive tourist
destination, a pleasant place to live, work and study, a city with responsible local
authorities, active citizens and a dynamic and involved business community.
4.3. Presentation of Cluj-Napoca
The information presented in this chapter derives mostly from the European Energy
Award© (EEA) assessment, which was conducted between September and
November 2012.
Sustainable Energy Action Plan 2011-2020 Cluj-Napoca
4
4.3.1. General information
Population
Cluj-Napoca is the second largest city in Romania. In 2011, 309,136 people were
officially registered as residents of the city, which represents 1.6% of Romania's total
population. More than 390,000 people live in the Cluj-Napoca metropolitan area.
Geography
Cluj-Napoca is the capital of the county of Cluj, located in the north-western part of
Romania (see Figure 1) in the Somesul Mic River valley. The city covers an area of
179.5 km2 with the Somesul Mic River running through the city.
Figure 1 Map of Romania, split into counties. The red area represents the city of Cluj-Napoca.
Sustainable Energy Action Plan 2011-2020 Cluj-Napoca
5
Climate Cluj-Napoca has a continental climate, characterised by warm, dry summers and cold
winters. The climate is influenced by the city's proximity to the Apuseni Mountains, as
well as by urbanisation. Some West-Atlantic influences are present during winter and
autumn. Winter temperatures are often below 0 °C, even though they rarely drop
below −10 °C. On average, snow covers the ground for 65 days each winter. In
summer, the average temperature is approximately 18 °C (the average for July and
August), despite the fact that temperatures sometimes reach 35 °C to 40 °C in mid-
summer in the city centre. Although average precipitation and humidity during
summer is low, there are infrequent yet heavy and often violent storms. During spring
and autumn, temperatures vary between 13 °C to 18 °C, and precipitation during this
time tends to be higher than in summer, with more frequent yet milder periods of rain.
Economy
In 2008, the city's general budget amounted to RON990 million (EUR220 million).
This meant an increase of roughly 250% compared to the 2005's general budget.
Cluj-Napoca is an important economic centre in Romania. Famous local brands that
have become well-known at a national, and to some extent even international level,
include: Banca Transilvania, Farmec, Jolidon, and Ursus breweries
http://en.wikipedia.org/wiki/Brewery.. The city is home to several universities and
hosts important software and IT companies, such as Bosch.
4.3.2. Municipal buildings and facilities
The municipality owns more than 100 buildings, mostly pre-schools, primary schools
and high schools (82). The consumption values for gas/heat, power and water are
known for the most important buildings; these have been recorded since 2012. The
majority of municipal buildings is connected to the local district heating network and
therefore sources heat for both space heating and hot water from this network.
A total of 464 km of streets are lit at night within the municipal territory. Street lighting
has been continually extended and renewed in recent years. In 2011, power
consumption for street lighting was 11.2 GWh/a.
4.3.3. Supply and disposal
The energy supply, water supply and waste water disposal of the municipality of Cluj-
Napoca are organised as follows:
Sustainable Energy Action Plan 2011-2020 Cluj-Napoca
6
Organisation level Operator Ownership
Electricity Regional Electrica SA Public
Natural Gas Regional E-ON Gas Private
District heating (production and network) Local
Autonomous Administration District Heating subordinated to the City Hall Public
Water supply County 1 operator Public
Waste water disposal and treatment County 1 operator Public
Waste collection County 2 operators Private
Landfill County 1 operator Private
Heat supply
Space heating and hot water are almost exclusively supplied using natural gas, either
via the municipal district heating network or private gas heating. Wood heating
systems are only used rarely. Additionally, several hundred solar thermal facilities
and several dozen heat pumps were installed in recent years. However, the share of
renewable heat generation is estimated to be less than 1%.
In 2011, the total gas consumption of the municipality of Cluj-Napoca exceeded
278 million m3, with private households being responsible for 43.6% of the total, and
economic and public entities for 56.4%.
Around 43 million m3 natural gas (431 GWh/a) were consumed for supplying heat via
the district heating network. Heat is generated by both cogeneration plants and
thermal power stations. A total of 34'000 flats are connected to the municipal district
heating network, corresponding to 41% of all flats (82'900) within the municipal
territory.
Around 10% of heat generation for the district heating network comes from a large,
central cogeneration plant and two smaller, decentralised cogeneration plants. With
an annual natural gas consumption of around 9 million m3, 40.2 GWh/a heat and
37.5 GWh/a power are fed into the network (efficiency factor of 84.8%). The losses in
the primary network (transport network) are currently 35%; those in the secondary
network (distribution network) 20%.
Power supply
In 2011, the estimated total power consumption within the municipal territory was
540 GWh/a. However, end consumers are currently not able to determine the power
mix, and the power mix of the municipality of Cluj-Napoca is therefore the same as
the mix for Romania as a whole.
Sustainable Energy Action Plan 2011-2020 Cluj-Napoca
7
Electricity within the municipal territory is mainly generated by the three gas-operated
municipal cogeneration power plants (37.5 GWh/a). Only few photovoltaic systems
have been installed. No electricity is generated from hydro power, biomass or wind
power within the municipal territory.
Water supply, waste water disposal and treatment
The municipal drinking water is sourced from a nearby lake and from aquifers. In
recent years, water supply pumps have been systematically replaced by new,
energy-efficient pumps (financed from EU funds). The energy consumption of the
drinking water supply is currently 0.3 kWh/m3. The leakage rate within the municipal
territory, which was still around 60% in 2000, was reduced to 50% by 2011, due to
continual upgrading of the network. Additional projects aimed at reducing this rate
further have already been planned, and funding via EU subsidies has already been
secured. It is envisaged that these projects will reduce the leakage rate to 25% by
2018.
The municipal waste water is treated in a sewage treatment plant located east of the
city, outside its residential areas, about 1 km from the airport. The plant achieves a
treatment ratio that is above the national average. However, compared to western
European standards, there still remains considerable need for action regarding waste
water treatment. The treatment plant has a self-sufficiency ratio of 50-60% as far as
its power needs are concerned.
Collection and storage of waste
Two private companies collect the municipal rubbish and transport it to a waste
disposal site that is also privately operated. The site has reached the end of its life
cycle and will therefore be replaced by a modern site in 2013. From then on, waste
will be used for energy production.
In 2009, around 130,000 tons of waste were collected, consisting of 50%
biodegradable waste, 21% paper and cardboard, 9% plastic, 6% glass and 4%
metals. Waste has been collected separately within the municipal territory since
2009. This applies to plastic, glass, textiles, metals and paper. The companies
responsible for waste collection are contractually obliged to provide separate
collection points and to communicate with residents to motivate them to separate
waste.
Sustainable Energy Action Plan 2011-2020 Cluj-Napoca
8
To date, green waste and kitchen waste have not been collected separately, as they
cannot be utilised separately at this stage. It is envisaged that green waste and
kitchen waste will also be collected and utilised separately as soon as the new waste
disposal site is operational.
The municipality has agreed to reduce the volume of waste deposited annually on
the waste disposal site by at least 50% by 2025, compared to 2009 volumes. This
goal is to be achieved mainly by building the new waste disposal site, collecting
green waste and kitchen waste separately, and promoting more awareness among
residents regarding waste avoidance and separation.
4.3.4. Mobility
Cluj-Napoca has a complex system of regional transportation, providing road, air and
rail connections to major cities in Romania and Europe. A traffic study was conducted
in 2010, a more comprehensive mobility study is planned for 2013.
Mobility strategy 2014-2020
The reduction of parking spaces and increase of prices for remaining parking spaces
in the city centre. In turn, new underground parking is to be provided, plus car parks
outside the city centre, which are to be closely connected to public transport (Park &
Ride). Pedestrian zones and reduced speed zones are to be additionally provided in
the city centre. Public transport availability is to be extended, and its quality to be
improved.
Motorised private transport
Cluj-Napoca is an important node in the European road network, being on three
different European routes (E60, E81 and E576). At a national level, the city is located
on three different main national roads: DN1, DN1C and DN1F. The Romanian
Motorway A3, also known as Transylvania Motorway (Autostrada Transilvania),
currently under construction, will link the city with Bucharest and Romania's western
border. The 2B section between Câmpia Turzii and Cluj Vest (Gilău) opened in late
2010.
In 2011, 73'096 passenger cars, 4747 mopeds, 19335 trucks were registered in the
city. The municipal car fleet consists of more than a dozen cars.
Sustainable Energy Action Plan 2011-2020 Cluj-Napoca
9
Public transport
Cluj-Napoca features a public transportation system (RATUC, Autonomous
Administration subordinated to City Hall) consisting of 213 diesel buses, 93 trolley
buses and 36 trams (see Table 1). It provides comprehensive, good access
throughout the entire city, i.e. from every point within the city a bus or tram stop can
be accessed on foot within 5-7 minutes. Buses and trams run every 4-5 minutes in
the city centre, less often in the city outskirts (operation hours: daily from 4.30am to
11.30pm). On average, 140.000 one way tickets are sold per day, and the
municipality subsidises public transportation tickets for students, pensioners and
children with more than RON25 million per year (EUR5.5 million). In 2011, electricity
consumption of trolley buses and trams accounted for 14.2 GWh/a, while buses
consumed 3.7 million litres of diesel. More than 50% of the buses and trams are old
and need to be replaced soon. Also, in peak traffic buses get stuck in traffic jams in
certain areas of the city centre (only 2-3 km separate bus lanes).
No Indicators Tramways Trolley buses Buses Total
1 Number of routes 3 6 37 46
2 Length of routes (km) 13.2 22 97.3 132.5
3 Transport vehicles 36 93 213 342
4 Average fleet working days 21 64 124 209
5 Average fleet non-working days
7 23 52 82
6 Percentage of passengers transported
23% 31% 46% 100%
7 Fleet utilization ratio(cup) 62% 69% 70%
Table 1 Comparative indicators for each division of public transport in Cluj-Napoca
Public parking
All public parking within the municipal territory is managed (Mondays - Saturdays,
7.00am - 9.00pm). Parking is free outside these times, except in car parks. Most of
the income from parking fees goes towards the municipality’s overall budget.
Pedestrians
Footpaths are provided on at least one side of most streets. In 2012, around 80% of
these footpaths were in good condition; hazardous points in the remaining 20% are
known, and measures have already been planned for improving the situation in the
coming years. Pedestrians are able to cross roads at appropriate distances. Major
pedestrian crossings have traffic lights and are clearly marked as crossings on the
road.
Sustainable Energy Action Plan 2011-2020 Cluj-Napoca
10
Cyclists
The plan "mobile Cluj" presents existing and planned routes for cyclists. In 2012,
there were about 59 km of cycle paths in the municipality, another 18 km are planned
in a project funded by the EU. They represent a network that extends and continues
to suburbs and aims to reduce car traffic, green transport and encourage the use of
bicycles as an alternative means of transport to improve urban mobility in Cluj
Metropolitan Area. This will be achieved by building a network of 50 stations in rental
bicycles self-service and developing a coherent network of tracks and trails for
cyclists, the territory of Cluj-Napoca, commune Floresti and village Apahida.
4.3.5. Internal organisation
The SEAP was prepared with the cooperation of the following institutions and
companies (SEAP Committee):
- Mrs. HORVATH Anna, Vice mayor / Cluj-Napoca City Hall- coordinator,
- Mrs. Moigradan Olimpia, Executive Director / Economic Department / Cluj-Napoca
City Hall - member,
- Mr. Porutiu Virgil , Executive Director / Technical Department / Cluj-Napoca City
Hallmember,
- Mrs. Ardeus Iulia, Executive Director / Department of Municipal Patrimony and
Property Records / Cluj-Napoca City Hall -member,
- Mr. Valer Suciu, Executive Director / Department of Administration / Cluj-Napoca
City Hall - member,
- Mrs. Madaras Julieta, Head of Budget Office / Economic Department / Cluj-
Napoca City Hall - member,
- Mr. loan Bogdan, Head of Financial Office /Economic Department / Cluj-Napoca
City Hall - member,
- Mrs. Magureanu Adriana , Head of Technical Office, Buildings Repair, Utilities
Monitoring / Technical Department / Cluj-Napoca City Hall - member,
- Mrs. Hent Liana, Head of Investments Office / Technical Department Cluj-Napoca
City Hall member,
- Mrs. Marincean Mirela, Head of Urban Traffic Safety, Urban Networks and Local
Transport / Technical Department / Cluj-Napoca City Hall - member,
- Mr. Moldovan Vasile, Head of the Green Spaces, Historic Monuments Urban
Ecology Office / Technical Department / Cluj-Napoca City Hall -member,
Sustainable Energy Action Plan 2011-2020 Cluj-Napoca
11
- Mrs. Miron Mihaela, Head of the Patrimony Records and Cadastre / Department of
Municipal Patrimony and Property Records / Cluj-Napoca City Hall -member,
- Mr. Madru Josif, Head of Human Resources Office / Cluj-Napoca City Hall,
- Mr. Raulea Adrian, Head of Strategy and Local Development, Project
Management Office/ Communications, Public Relations and Tourism Department /
Cluj-Napoca City Hall - member ,
- Mrs. Spiroiu Sanda, Head of the Urban Planning Office / Urban Planning
Department / Cluj-Napoca City Hall - member,
- Mrs. Muresan Oana, Head of the Citizen Information Centre / Cluj-Napoca City
Hall - member,
- Mrs. Ana Maria Lazarica, Project Manager Advisor, Strategy and Local
Development, Project Management Office / Communications, Public Relations and
Tourism Department / Cluj-Napoca City Hall - member
- Mr. Revesz Bogdan Alexandru, Project Manager Advisor, Strategy and Local
Development, Project Management Office / Communications, Public Relations and
Tourism Department / Cluj-Napoca City Hall - member,
- A representative of the Autonomous Administration of Urban Passenger Transport
Cluj-Napoca
- Technical Director of the Autonomous Administration of District Heating Cluj-
Napoca
- A representative of the Somes Water Company SA Cluj-Napoca
- A representative of the Chamber of Commerce and Industry Cluj
- A representative of the County School Inspectorate Cluj
- A representative of the Technical University of Cluj-Napoca
- A representative of Babes –Bolyai University
- A representative of the Environmental Protection Agency Cluj
The same committee supported the European Energy Award process. The SEAP
Committee will be responsible for implementing the measures set out in the SEAP
and for meeting the CO2 target.
An energy department will additionally be created soon. This department will be
responsible for coordinating the energy-related projects, for collecting relevant data
centrally, and for monitoring progress towards achieving the targets.
Sustainable Energy Action Plan 2011-2020 Cluj-Napoca
12
Performance specifications have been established for all municipal employees, and
external service providers are subject to contractual performance obligations. These
will be supplemented by energy-related aspects as soon as possible.
4.3.6. Communication channels
The municipality uses the following channels for external communication:
- Website
- IT system – e-administration
- Press conferences (local television stations, news portal operators, local press)
- Press releases
- Mayor’s Facebook and Twitter pages
- Posters
- Magazine (printed; distributed to households 4 x per year; print run of 100,000)
Internal communication uses the municipality’s own online platform (intranet) and the
staff magazine.
4.4. Financial aspects and monitoring
4.4.1. Financial sources
The municipality’s costs of achieving the CO2 targets by 2020 are around EUR180
million. The necessary funds will come from the following budgets and funds:
- Budget of the municipality, the metropolitan area and the county
- Governmental funds
- International funds (i.e. European Union, Swiss-Romanian Cooperation Program)
4.4.2. Monitoring
Implementation and monitoring committee members, will be responsible for
monitoring the activities listed in section 6. It will provide an annual progress report to
the SEAP Committee. Additionally, an implementation report will be submitted to the
Covenant of Mayors every two years, setting out the current progress of SEAP
implementation and the effects of measures already implemented.
Among others, the European Energy Award tools will be used for implementation and
to support monitoring.
Sustainable Energy Action Plan 2011-2020 Cluj-Napoca
13
5. Baseline Emission Inventory
5.1. Final energy consumption
In 2011, the final energy consumption of Cluj-Napoca amounted to roughly 3.4 TWh.
Table 2 shows energy consumption by sector and energy carrier.
Electricity Heat/cold
Natural Gas
Diesel Petrol Total
Buildings, Equipment/Facilities:
Municipal buildings, equipment/facilities 289'402 289'402 289'402 289'402 289'402 289'402
Tertiary buildings, equipment/facilities 754'239 754'239 754'239 754'239 754'239 754'239
Residential buildings 1'635'380 1'635'380 1'635'380 1'635'380 1'635'380 1'635'380
Municipal public lighting 11'263 11'263 11'263 11'263 11'263 11'263
Subtotal 363'676 170'493 2'156'115 0 0 2'690'285
Transport:
Municipal fleet 0 0 0 0 143 143
Public transport 14'193 0 0 36'734 0 50'927
Private and commercial transport 0 0 0 300'188 324'145 624'333
Subtotal 14'193 0 0 336'922 324'288 675'402
Total 377'869 170'493 2'156'115 336'922 324'288 3'365'687
Table 2 Final energy consumption of Cluj-Napoca in 2011 (values are in MWh/a)
5.2. CO2 emissions
Energy consumption in 2011 caused CO2 emissions of almost 1 million tons.
Emission values by sector and energy carrier are shown in Table 3.
Electricity Heat/cold
Natural Gas
Diesel Petrol Total
Buildings, Equipment/Facilities:
Municipal buildings, equipment/facilities 3'795 1'147 56'942 0 0 61'884
Tertiary buildings, equipment/facilities 69'883 2'910 131'144 0 0 203'937
Residential buildings 173'364 89'202 247'449 0 0 510'015
Municipal public lighting 7'895 0 0 0 0 7'895
Subtotal 254'937 93'260 435'535 0 0 783'732
Transport:
Municipal fleet 0 0 0 0 35 35
Public transport 9'949 0 0 9'808 0 19'757
Private and commercial transport 0 0 0 80'150 80'712 160'862
Subtotal 9'949 0 0 89'958 80'748 180'655
Total 264'886 93'260 435'535 89'958 80'748 964'387 Table 3 CO2 emissions of Cluj-Napoca in 2011 (values are in tons per year (t/a))
The calculated CO2 emissions are based on the CO2-emission factors shown in
Table 4.
Electricity Heat/cold Natural Gas Diesel Petrol
CO2-emission factors [in t/MWh] 0.701 0.547 0.202 0.267 0.249
Table 4 CO2-emission factors used for the calculation of the values presented in Table 3.
Sustainable Energy Action Plan 2011-2020 Cluj-Napoca
14
5.2.1. Local electricity generation and related CO2 emissions
More than 37 GWh/a of electricity was generated locally by cogeneration power
plants in 2011. Natural gas alone was used as energy input (see Table 5).
Locally generated electricity [MWh/a]
Energy input:
Natural gas (MWh/a)
CO2 emissions
[t/a]
Corresponding CO2-emission factors for
electricity generation in [t/MWh]
Combined Heat and Power 37'453 61'019 12'326 0.329
Total 37'453 61'019 12'326
Table 5 Local electricity generation in Cluj-Napoca in 2011 and corresponding CO2 emissions.
5.2.2. Local urban heating and corresponding emissions
About 293 GWh/a of heat was produced locally by cogeneration power plants and
district heating plants in 2011. Only natural gas was used as energy input (see Table
6).
Locally generated
heat
[MWh/a]
Energy input:
Natural gas (MWh/a)
CO2 emissions
[t/a]
Corresponding CO2-emission factors for heat production in
[t/MWh]
Combined Heat and Power 40'155 30'509 6'163 0.153
District Heating Plants 253'811 431'260 87'115 0.343
Total 293'966 461'769 93'277 Table 6 Local heat production in Cluj-Napoca in 2011 and corresponding CO2 emissions.
Sustainable Energy Action Plan 2011-2020 Cluj-Napoca
15
6. Planned Actions and Measures until 2020
This section sets out the measures that have been planned in order to ensure that
the CO2 reduction targets will be reached. The measures cover the following areas:
- Buildings, equipment/facilities (municipal buildings, tertiary buildings, residential
buildings, public lighting)
- Transport (municipal fleet, public transport, private and commercial transport)
- Local electricity production (photovoltaic, green certificates)
- Local heating/cooling (district heating, CHPs, solar thermal power plants, air
conditioning)
- Land use planning
- Public procurement
- Working with citizens and stakeholders
- Internal organisation
Estimated costs [EUR]
Expected energy saving
[MWh/a]
Expected renewable
energy production
[MWh/a]
Expected CO2
reduction [t/a]
Buildings, Equipment / Facilities 72'600'000 435'800 0 87'670
Transport 61'900'000 139'330 0 44'907
Local Electricity Production 1'100'000
0 38'400 26'900 1'500'000/a
Local Heating / Cooling 22'400'000 88'600 172'500 53'300
Land Use Planning 6'040'000 0 0 0
Public Procurement 0 0 0 0
Working with the Citizens and Stakeholders
1'400'000 0 0 0
290'000/a
Internal Organisation 0 0 0 0
Total 165'440'000
663'730 210'900 212'777
1'790'000/a
Reduction in % 20% 22%
Table 7 provides an overview of the expected costs associated with implementing the measures planned by the municipality of Cluj-Napoca. For 2013-2020, these are around EUR180 million, with recurring annual costs making up around 10% of the total. It is expected that the implementation of planned measures will result in a reduction in CO2 emissions of 22% and in energy savings of around 20%. Additionally, the portion of renewable sources of energy in the total energy mix will increase by 8%.
Sustainable Energy Action Plan 2011-2020 Cluj-Napoca
16
Estimated costs [EUR]
Expected energy saving
[MWh/a]
Expected renewable
energy production
[MWh/a]
Expected CO2
reduction [t/a]
Buildings, Equipment / Facilities 72'600'000 435'800 0 87'670
Transport 61'900'000 139'330 0 44'907
Local Electricity Production 1'100'000
0 38'400 26'900 1'500'000/a
Local Heating / Cooling 22'400'000 88'600 172'500 53'300
Land Use Planning 6'040'000 0 0 0
Public Procurement 0 0 0 0
Working with the Citizens and Stakeholders
1'400'000 0 0 0
290'000/a
Internal Organisation 0 0 0 0
Total 165'440'000
663'730 210'900 212'777
1'790'000/a
Reduction in % 20% 22%
Table 7 Overview of expected costs and effects of planned measures
Sustainable Energy Action Plan 2011-2020 Cluj-Napoca
17
6.1. Buildings, Equipment and Facilities
No. Fields of action KEY actions/measures Responsible
department, person or company
Implementation period
Estimated costs [EUR]
Expected energy saving
[MWh/a]
Expected renewable
energy production
[MWh/a]
Expected CO2
reduction [t/a]
1 Municipal buildings, equipment/facilities
Refurbishment of 71 schools and kindergartens (21 thermal rehabilitation, 20 modernisation of heating source, 30 thermal rehabilitation + modernisation of heating source)
Technical department 2013-2020 70'000'000 85'000 0 17'000
2 Municipal buildings, equipment/facilities
Energy efficient lighting in municipal buildings (LED)
Technical department 2013-2016 1'000'000 400 0 300
3 Municipal buildings, equipment/facilities
Energy review of all municipal buildings
Technical department 2013 0 0 0 0
4 Municipal buildings, equipment/facilities
Refurbishment concept Technical department 2013 0 0 0 0
5 Tertiary (non municipal) buildings, equipment/facilities
Renewal/rehabilitation rate of 3% per year for tertiary buildings Achieved via access to funds at favourable conditions (e.g. measures 53, 55); various communication measures (e.g. measures 51, 57, 58, 60); national funding programmes and EU funding. Values represent heat in the form of space heating and hot water.
Building owners 2013-2020 100'000 0 20'000
Sustainable Energy Action Plan 2011-2020 Cluj-Napoca
18
6 Residential buildings Renewal/rehabilitation rate of 3% per year for residential buildings (blocks of flats and individual houses). Achieved via access to funds at favourable conditions (e.g. measures 53-55); various communication measures (e.g. measures 51, 57, 60); national funding programmes and EU funding. Values represent heat in the form of space heating and hot water.
Building/apartment owners
2013-2020 250'000 0 50'000
7 Municipal public lighting Introduction of telemanagement for public lighting (dimming, overnight shutdown).
Technical department + EnergoBit + Elin GmbH
2013 200'000 100 0 70
8 Municipal public lighting 1358 LED lamps for public lighting
Technical department 2013 1'400'000 300 0 300
Sustainable Energy Action Plan 2011-2020 Cluj-Napoca
19
6.2. Transport
No. Fields of action KEY actions/measures Responsible
department, person or company
Implementation period
Estimated costs [EUR]
Expected energy saving
[MWh/a]
Expected renewable
energy production
[MWh/a]
Expected CO2
reduction [t/a]
9 Municipal fleet High energetic standards for new cars in the public car fleet
Technical department + Strategy department 2013 0 0 0 0
10 Municipal fleet Replacement of 3 police cars Technical department 2013-2017 100'000 30 0 7
11 Municipal fleet Monitoring of public car fleet fuel consumption
Administrative department 2013 0 0 0 0
13 Public transport 12 new electric buses for public transport (replacement of old diesel buses)
RATUC + Technical department
2013 5'400'000 1'600 0 300
14 Public transport 12 new articulated trolley buses (replacement of old diesel buses)
RATUC + Technical department 2014 6'200'000 1700 0 200
15 Public transport 4 new trams (replacement of old trams)
RATUC + Technical department 2014 5'900'000 200 0 100
16 Public transport Extension of 7km tramway to Floresti
RATUC + Technical department 2013-2015 6'400'000 0 0 0
17 Public transport Modernisation of the tram section Manastur-Railway Station Market
RATUC + Technical department 2014-2014 17'000'000 300 0 200
18 Public transport Modernisation of the tram section Piata Garii - Bulevardul Muncii
RATUC + Technical department 2013-2014 15'000'000 300 0 200
19 Public transport Introduction of e-ticketing system for public transport (improved convenience)
RATUC + Technical department
2013-2014 1'000'000 0 0 0
20 Private and commercial transport
3% reduction of private transport in the city area as a result of the implementation of measures 13-19, 21-25, 44-47, 57-58, 60
Technical department + PR department + urban planning department + car owners
2013-2020 15'000 0 3'800
21 Private and commercial transport
Periodic replacement of old passenger cars by more efficient cars
Car owners
2013-2020 120'000 0 40'000
22 Private and commercial transport
Speed reduction zones Technical department + traffic safety, urban and local transport networks department 2013-2015 1'000'000 200 0 100
Sustainable Energy Action Plan 2011-2020 Cluj-Napoca
20
23 Private and commercial transport
Self-service bike rental network (51 rental stations, 500 bikes, 35km signposted new bike routes and dedicated lanes)
Technical department + Strategy department
2013 3'900'000 0 0 0
24 Private and commercial transport
Park & Ride: provision of new car parks in the municipality’s outer suburbs, which are to be closely connected to public transport.
Technical department + Strategy department
2014-2017 to be
evaluated 0 0 0
25 Private and commercial transport
Public-private partnership project to introduce car sharing offers
Technical department + Strategy department 2013-2016 0 0 0 0
Sustainable Energy Action Plan 2011-2020 Cluj-Napoca
21
6.3. Local electricity production
No. Fields of action KEY actions/measures Responsible
department, person or company
Implementation period
Estimated costs [EUR]
Expected energy saving
[MWh/a]
Expected renewable
energy production
[MWh/a]
Expected CO2
reduction [t/a]
26 Photovoltaic 10 MW PV power plant on 197.86 ha. The city will receive 30% of total production.
Technical department 2013-2014 0 0 3'500 2'500
27 Photovoltaic 2 PV power plants, 370 kW (charging stations for electric public transport buses)
RATUC 2013 700'000 0 400 300
28 Photovoltaic 150 kW photovoltaic power plants on municipal buildings
Technical department 2013-2017 300'000 0 1'600 1'100
29 Photovoltaic Photovoltaic power plants on tertiary buildings
Building owners 2013-2020 0 0 1'100 800
30 Photovoltaic Photovoltaic power plants on residential buildings (30% through funding programme)
Building/apartment owners
2014-2016 0 0 1'800 1'200
31 Green Certificates Purchase of Romanian green certificates for covering the power needs of municipal buildings and facilities, public lighting and public transport (to supplement municipal power generation plants). Cost: EUR50/MWh (hydro power), recurring annually until there is sufficient municipal power generation from renewable sources of energy.
Technical department 2013 1'500'000/a 0 30'000 21'000
32 Electricity supply The municipality will cooperate with other municipalities and promote the ability of all consumers within the municipality to choose their power mix.
Strategy department 2013-2020 0 0 0 0
Sustainable Energy Action Plan 2011-2020 Cluj-Napoca
22
6.4. Local heating and cooling
No. Fields of action KEY actions/measures Responsible
department, person or company
Implementation period
Estimated costs [EUR]
Expected energy saving
[MWh/a]
Expected renewable
energy production
[MWh/a]
Expected CO2
reduction [t/a]
33 Combined Heat and Power 2 decentralised cogeneration power plants
RAT 2014-2015 1'600'000 2'000 0 1'400
34 Combined Heat and Power Landfill gas recovery and cogeneration power plant
Cluj-Napoca City Hall 2013 to be evaluated
0 to be evaluated
to be evaluated
35 Combined Heat and Power Biomass plant at new landfill (incl. biomass from waste)
Cluj-Napoca City Hall 2013 to be evaluated
0 to be evaluated
to be evaluated
36 District heating network Refurbishment of primary network (transport). Reduction of losses from 35% to 15%.
RAT 2013-2016
16'000'000
60'000 0 12'000
37 District heating network Refurbishment of secondary network (distribution). Reduction of losses from 20% to 10%.
RAT 2013-2016 26'000 0 5'000
38 Solar thermal power plants 10 solar thermal power plants on central heating power plants
RAT 2014 1'100'000 0
39 Solar thermal power plants 5'000m2 solar thermal panels on municipal buildings
Technical department 2013-2017 3'200'000 0 2'500 500
40 Solar thermal power plants 240'000m2 solar thermal panels on residential buildings
Building/apartment owners
2013-2020 0 120'000 24'000
41 Solar thermal power plants 100'000m2 solar thermal panels on tertiary buildings
Building owners 2013-2020 50'000 10'000
42 Cooling Replacement of around 500 air-conditioning units in municipal buildings by more efficient units.
Technical department 2013-2020 500'000 600 0 400
43 Industrial heat Assessment of industrial waste heat potential on city area
Strategy department 2013 0 0 0 0
Sustainable Energy Action Plan 2011-2020 Cluj-Napoca
23
6.5. Land use planning
No. Fields of action KEY actions/measures Responsible
department, person or company
Implementation period
Estimated costs [EUR]
Expected energy saving
[MWh/a]
Expected renewable
energy production
[MWh/a]
Expected CO2
reduction [t/a]
44 Transport / mobility planning Development of a comprehensive mobility plan
Technical department + Strategy department
2013 40'000 0 0 0
45 Transport / mobility planning Extension of separate bus lanes network
Technical department + Strategy department
2014-2017 6'000'000 0 0 0
46 Transport / mobility planning Implementation of public policies to reduce traffic in the city centre
Technical department + Strategy department
2013-2017 0 0 0 0
47 Transport / mobility planning Increased parking fees in the city centre
Technical department + Strategy department
2013 0 0 0 0
48 Standards for refurbishment and new development
Minimum energetic requirements for tenders
Technical department (public acquisition)
2013 0 0 0 0
49 Standards for refurbishment and new development
High energetic standards (efficiency and renewables) for new municipal buildings and major refurbishment work
Urban planning department + Technical department
2013 0 0 0 0
6.6. Public procurement
No. Fields of action KEY actions/measures Responsible
department, person or company
Implementation period
Estimated costs [EUR]
Expected energy saving
[MWh/a]
Expected renewable
energy production
[MWh/a]
Expected CO2
reduction [t/a]
50 Energy efficiency requirements/standards
Green procurement guidelines for city hall: highly energy efficient products, recycled materials
Public procurement department + Energy department
2013 0 0 0 0
Sustainable Energy Action Plan 2011-2020 Cluj-Napoca
24
6.7. Working with citizens and stakeholders
No. Fields of action KEY actions/measures Responsible
department, person or company
Implementation period
Estimated costs [EUR]
Expected energy saving
[MWh/a]
Expected renewable
energy production
[MWh/a]
Expected CO2
reduction [t/a]
51 Advisory services Intensification of consultation of building-owners
Urban planning department
2014-2020 0 0 0 0
52 Financial support and grants Subsidies for PV panels on residential buildings and lands (30% of investment costs)
Financial department 2014-2016 1'000'000 0 0 0
53 Financial support and grants Cooperation with local banks. Low interest credits for solar thermal or photovoltaic power plants and thermal rehabilitation of buildings. Active promotion of offers through the municipality.
PR department + local banks
2013-2020 400'000 0 0 0
54 Financial support and grants Subsidies for energy audits and energy performance certificates for 200 blocks of flats.
Financial department 2013-2020 1'300'000 0 0 0
55 Financial support and grants 50% property tax reduction for green building owners
Financial department 2013-2020 2'000'000 0 0 0
56 Awareness raising and local networking
Communication concept. Points out what needs to be communicated when to whom in what way.
PR department 2013 0 0 0 0
57 Awareness raising and local networking
Cooperation with professional investors (congress on energy, climate and mobility relevant topics, 2 days a year)
Urban planning department + Patrimony department
2013-2020 200'000 0 0 0
Sustainable Energy Action Plan 2011-2020 Cluj-Napoca
25
58 Awareness raising and local networking
Close partnership with industry and business (congress on energy, climate and mobility relevant topics, 1 day a year)
Investors + Foreign investors department
2013-2020 100'000 0 0 0
59 Awareness raising and local networking
Communication campaign for selective waste collection
Private waste collection companies + PR department
2013-2020 80'000/a 0 0 0
60 Awareness raising and local networking
Raising awareness campaigns on energy issues (energy day and mobility day, once a year)
Energy department + PR department
2013-2020 200'000/a 0 0 0
61 Training and education Energy-related further training for municipal employees
Energy department 2013-2020 10'000/a 0 0 0
62 Training and education Distribution of a manual of environmental good practices and energy saving to municipal employees
Energy department 2013 0 0 0 0
6.8. Internal organisation
No. Fields of action KEY actions/measures Responsible
department, person or company
Implementation period
Estimated costs [EUR]
Expected energy saving
[MWh/a]
Expected renewable
energy production
[MWh/a]
Expected CO2
reduction [t/a]
63 Internal organisation New energy department with specialised staff (energy efficiency, renewables, monitoring, strategies, communication, events, further training)
HR department 2013 0 0 0 0
64 Internal organisation Allocation of responsibilities for monitoring of energy consumption (public buildings, city area, …)
Energy department + HR department
2013 0 0 0 0
Sustainable Energy Action Plan 2011-2020 Cluj-Napoca
26
Appendix
List of appendices
Appendix 1 - SEAP committee
Appendix 2 - Letter of Recognition (European Energy Award)
Sustainable Energy Action Plan 2011-2020 Cluj-Napoca
27
Appendix 1 - SEAP committee
Sustainable Energy Action Plan 2011-2020 Cluj-Napoca
28
Sustainable Energy Action Plan 2011-2020 Cluj-Napoca
29
Appendix 2 - Letter of Recognition (European Energy Award)
Sustainable Energy Action Plan 2011-2020 Cluj-Napoca
30