Upload
others
View
9
Download
0
Embed Size (px)
Citation preview
WATERPROOFING SPECIFICATIONS AND METHODOLOGIES
SWIMMING POOL 101
Concrete Waterproofing and Durability Enhancement Using DPC Supershield Crystalline Technology
www.supershieldglobal.com
SWIMMING POOL - PREREQUISITE FOR SUPERSHIELD WATERPROOFING TREATMENT
l The SWIMMING POOL that is to be treated should be minimum 7 days old.
SUPERSHIELD SPECIFICATION AND APPLICATION METHODOLOGY
Provide, mix and brush apply two coats of SUPERSHIELD CRYSTALGUARD, single compound Deep Penetrating
Capillary (DPC) waterproofing system that generates a non-soluble crystalline formation of dendritic fibers within
the pores and capillary tracts of the concrete @ 1.5 Kg/m² for two coats on the walls and the floor area of the
Swimming pool.
1) Surface preparation - The concrete substrate that to be applied with SUPERSHIELD
CRYSTALGUARD must be free from foreign materials and to be micro cleaned by mechanical means like
wire brushing or vacuum cleaning.
2) Pre-wetting - Concrete surface must be thoroughly saturated with clean water prior to the coating to
ensure moisture presence inside the pores and capillaries and remove any excess water and ensure
surface is touch dry while coating.
3) Mixing of CRYSTALGUARD - Mix SUPERSHIELD CRYSTALGUARD powder with clean water to form a
slurry consistency with 5 parts of powder and 2 parts of water.
4) Application of CRYSTALGUARD - Apply the first coat of SUPERSHIELD CRYSTALGUARD as a slurry
consistency on the concrete surface.
Concrete Substrate
Application Methodology
TWO COATS OF CRYSTALGUARD @ 1.5 Kg/m²
SWIMMING POOL - 101 Page 1 of 3
SWIMMING POOL
SUPERSHIELD CRYSTALGUARD FIRST COATING
SUPERSHIELDCRYSTALGUARD SECOND COATING
Construction Joint
5) Second coat of CRYSTALGUARD - Apply the second coat of SUPERSHIELD CRYSTALGUARD as a
slurry consistency on the first coat after a minimum of 4 hours gap.
l The SUPERSHIELD CRYSTALGUARD coating should be cured with a misty fog spray of clean water, 24 hours
after the application and to be kept moist for minimum 3 days.
Cracks, horizontal, vertical joint sealing, tie hole, pipe penetrations, construction joints, expansion joints and
other defects in the concrete that to be waterproofed should be treated as per the SUPERSHIELD specification
and application methodology.
Crystalline waterproofing system should meet or exceed the performance requirements as specified herein.
l Crystalline Penetration : Crystallizing capability of waterproofing material shall be evidenced by
independent SEM (Scanning Electron Microscope) photographs documenting penetration of needle like
crystal formation deep within concrete.
l Self-healing capability and permeability resistance : Independent testing performed according to U.S. Army
Corps of Engineers CRD-C48-73 "Permeability of Concrete".
l Testing on the effectiveness of coating from negative side of concrete : Independent testing that
demonstrates the capability of the coating to seal the leakage/dampness from negative side.
l Resistance to chloride ion penetration : Independent testing performed according to ASTM C 1202-03
should exhibit a resistance of 100% better than that of the untreated specimen.
l Potable Water Approval : Independent testing shall be performed according to EN or NSF Standard 61, and
approval for use of waterproofing material on structures holding potable water shall be evidenced.
A) Manufacturer : Manufacturer should publish a third party product quality assurance certificate from a notified
body with continuous surveillance audit or CE certificate with FPC (Factory Production Control) as per the
harmonized standard EN to prove that the facility from where the material is produced for the project has
undergone the required testing and extensive inspection and is under continuous surveillance by a notified body
appointed by the European union as per the European norms for the system. Manufacturers who cannot provide
the performance test data specified herein and FPC certificate shall not be considered for the project.
B) Applicator : Waterproofing applicator shall be experienced in the installation of cementitious crystalline
waterproofing materials and shall be approved by the manufacturer in writing.
Curing
Watch Points
Performance Criteria
Quality Assurance
www.supershieldglobal.com SWIMMING POOL - 101 Page 2 of 3
WATERPROOFING SPECIFICATIONS AND METHODOLOGIES
SWIMMING POOL 101
Concrete Waterproofing and Durability Enhancement Using DPC Supershield Crystalline Technology
TWO COATS OF CRYSTALGUARD @ 1.5 Kg/m²
Warranty
Submittals
A) Manufacturer's Warranty : Manufacturer shall provide standard product warranty executed by authorised
company official.
B) Applicator's Warranty : Applicator shall warrant the waterproofing installation against defects caused by faulty
workmanship or materials for a period of (specify term) years from Date of Substantial Completion. The warranty
will cover the surfaces treated and will bind the applicator to repair, at his expense, any and all leaks through the
treated surfaces which are not due to structural weaknesses or other causes beyond applicator's control such as
fire, earthquake and cyclone.
Product data sheets, Application guidelines, Material safety data sheet, CE certificate, Summary of test reports.
www.supershieldglobal.com SWIMMING POOL - 101 Page 3 of 3
WATERPROOFING SPECIFICATIONS AND METHODOLOGIES
SWIMMING POOL 101
Concrete Waterproofing and Durability Enhancement Using DPC Supershield Crystalline Technology
TWO COATS OF CRYSTALGUARD @ 1.5 Kg/m²
www.supershieldglobal.com
SWIMMING POOL - PREREQUISITE FOR SUPERSHIELD WATERPROOFING TREATMENT
l The SWIMMING POOL that is to be treated should be minimum 7 days old.
SUPERSHIELD SPECIFICATION AND APPLICATION METHODOLOGY
Provide, mix and brush apply one coat of SUPERSHIELD CRYSTALGUARD, single compound Deep Penetrating
Capillary (DPC) waterproofing system @ 0.75 Kg/m² and one coat of SUPERSHIELD CRYSTALGUARD ULTIMA,
single compound highly concentrated crystalline coating as a top coat that generates a non-soluble crystalline
formation of dendritic fibers within the pores and capillary tracts of the concrete with hard surface finish @ 0.75
Kg/m² on the wall and the floor area of the Swimming Pool.
1) Surface preparation - The concrete substrate that is to be applied with SUPERSHIELD
CRYSTALGUARD /ULTIMA must be free from foreign materials and to be micro cleaned by mechanical
means like wire brushing or vacuum cleaning.
2) Pre-wetting - Concrete surface must be thoroughly saturated with clean water prior to the coating to
ensure moisture presence inside the pores and capillaries and remove any excess water to ensure
surface is touch dry while coating.
3) Mixing of CRYSTALGUARD - Mix SUPERSHIELD CRYSTALGUARD powder with clean water to form a
slurry consistency with 5 parts of powder and 2 parts of water.
Concrete Substrate
Application Methodology
WATERPROOFING SPECIFICATIONS AND METHODOLOGIES
2 ONE COAT OF CRYSTALGUARD & ONE COAT OF CRYSTALGUARD ULTIMA @ 1.5 Kg/m
SWIMMING POOL 102
SWIMMING POOL - 102 Page 1 of 3
SWIMMING POOL
SUPERSHIELDCRYSTALGUARDCOATING
SUPERSHIELDCRYSTALGUARD ULTIMACOATING
Construction Joint
Concrete Waterproofing and Durability Enhancement Using DPC Supershield Crystalline Technology
4) Application of CRYSTALGUARD - Apply one coat of SUPERSHIELD CRYSTALGUARD as a slurry
consistency on to the concrete surface.
5) Mixing of CRYSTALGUARD ULTIMA - Mix SUPERSHIELD CRYSTALGUARD ULTIMA powder with
clean water to form a slurry consistency withf 5 parts of powder and 2 parts of water.
6) Application of CRYSTALGUARD ULTIMA - Apply one coat of SUPERSHIELD CRYSTALGUARD
ULTIMA as a slurry consistency on the CRYSTALGUARD coating minimum after 4 hours gap as a top
coating.
Cracks, horizontal, vertical joint sealing, tie hole, pipe penetrations, construction joints, expansion joints and
other defects in the concrete that to be waterproofed should be treated as per the SUPERSHIELD specification
and application methodology.
Crystalline waterproofing system should meet or exceed the performance requirements as specified herein.
l Crystalline Penetration : Crystallizing capability of waterproofing material shall be evidenced by
independent SEM (Scanning Electron Microscope) photographs documenting penetration of needle like
crystal formation deep within concrete.
l Self-healing capability and permeability resistance : Independent testing performed according to U.S. Army
Corps of Engineers CRD-C48-73 "Permeability of Concrete".
l Testing on the effectiveness of coating from negative side of concrete : Independent testing that
demonstrates the capability of the coating to seal the leakage/dampness from negative side.
l Resistance to chloride ion penetration : Independent testing performed according to ASTM C 1202-03
should exhibit a resistance of 100% better than that of the untreated specimen.
l Potable Water Approval : Independent testing shall be performed according to EN or NSF Standard 61, and
approval for use of waterproofing material on structures holding potable water shall be evidenced.
A) Manufacturer : Manufacturer should publish a third party product quality assurance certificate from a notified
body with continuous surveillance audit or CE certificate with FPC (Factory Production Control) as the per the
harmonized standard EN to prove that the facility from where the material is produced for the project has
Curing
Watch Points
Performance Criteria
Quality Assurance
l The SUPERSHIELD CRYSTALGUARD/ ULTIMA coating should be cured with a misty fog spray of clean water,
24 hours after the application and to be kept moist for minimum 3 days.
www.supershieldglobal.com SWIMMING POOL - 102 Page 2 of 3
WATERPROOFING SPECIFICATIONS AND METHODOLOGIES
2 ONE COAT OF CRYSTALGUARD & ONE COAT OF CRYSTALGUARD ULTIMA @ 1.5 Kg/m
SWIMMING POOL 102
Concrete Waterproofing and Durability Enhancement Using DPC Supershield Crystalline Technology
undergone the required testing and extensive inspection and is under continuous surveillance by a notified body
appointed by the European union as per the European norms for the system. Manufacturers who cannot provide
the performance test data specified herein and FPC certificate shall not be considered for the project.
B) Applicator : Waterproofing applicator shall be experienced in the installation of cementitious crystalline
waterproofing materials and shall be approved by the manufacturer in writing.
A) Manufacturer's Warranty : Manufacturer shall provide standard product warranty executed by authorised
company official.
B) Applicator's Warranty : Applicator shall warrant the waterproofing installation against defects caused by
faulty workmanship or materials for a period of (specify term) years from Date of Substantial Completion. The
warranty will cover the surfaces treated and will bind the applicator to repair, at his expense, any and all leaks
through the treated surfaces which are not due to structural weaknesses or other causes beyond applicator's
control such as fire, earthquake and cyclone.
Product data sheets, Application guidelines, Material safety data sheet, CE certificate, Summary of test reports.
Warranty
Submittals
www.supershieldglobal.com SWIMMING POOL - 102 Page 3 of 3
WATERPROOFING SPECIFICATIONS AND METHODOLOGIES
2 ONE COAT OF CRYSTALGUARD & ONE COAT OF CRYSTALGUARD ULTIMA @ 1.5 Kg/m
SWIMMING POOL 102
Concrete Waterproofing and Durability Enhancement Using DPC Supershield Crystalline Technology