Installation Guide METERBOX-IEN110611 3

Table of Contents1 Information on this Manual. . . . . . . . . . . . . . . . . . . . . . . . . 51.1 Validity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 51.2 Target Group . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 51.3 Symbols Used . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 52 The Meter Connection Box . . . . . . . . . . . . . . . . . . . . . . . . . 63 Safety . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 73.1 Appropriate Usage. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 73.2 Safety Instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 84 Unpacking. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 84.1 Scope of Delivery . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 84.2 Identifying the Product . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 94.2.1 Type Label. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .94.2.2 Firmware Version and Hardware Version . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9

5 Mounting. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 105.1 Selecting the Mounting Location. . . . . . . . . . . . . . . . . . . . . . . . 105.2 Mounting the Meter Connection Box on the Wall . . . . . . . . . . 105.3 Mounting the Meter Connection Box on the Top-Hat Rail . . . . 126 Electrical Connection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 146.1 Device Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 146.2 LED Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 146.3 Connecting the Meter Connection Box to the RS485

Communication Bus . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 156.4 Terminating the Meter Connection Box . . . . . . . . . . . . . . . . . . 176.5 Connecting the Meter Connection Box to an Energy Meter. . . 17

Page 4: System Monitoring METER CONNECTION BOX

Table of Contents SMA Solar Technology AG

4 METERBOX-IEN110611 Installation Guide

7 Commissioning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 187.1 Connecting the Meter Connection Box to the Power Supply . . 187.2 Detecting the Meter Connection Box with the

Sunny WebBox. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 187.3 Setting the Meter Connection Box Parameters . . . . . . . . . . . . . 188 Maintenance and Care . . . . . . . . . . . . . . . . . . . . . . . . . . . 198.1 Maintenance. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 198.2 Care . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 199 Decommissioning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 209.1 Disassembling the Meter Connection Box . . . . . . . . . . . . . . . . 209.2 Packaging the Meter Connection Box . . . . . . . . . . . . . . . . . . . 209.3 Disposing of the Meter Connection Box . . . . . . . . . . . . . . . . . . 2010 Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2111 Parameter Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2211.1 Display Values . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2211.2 Adjustable Parameters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2312 Technical Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2512.1 Meter Connection Box . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2512.2 Plug-in Power Supplies . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2612.2.1 CINCON, TRG30R 120. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2612.2.2 TaiyTech, TYT251200200UV/3000 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2612.2.3 TaiyTech, TYT251200200EU/3000 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27

13 Contact . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28

Page 5: System Monitoring METER CONNECTION BOX

SMA Solar Technology AG Information on this Manual

Installation Guide METERBOX-IEN110611 5

1 Information on this Manual1.1 ValidityThis manual is valid for the Meter Connection Box from hardware version A and firmware version 1.0 and higher.

1.2 Target GroupThis manual is intended for installers.

1.3 Symbols UsedThe following types of safety precautions and general information appear in this document:

DANGER!

DANGER indicates a hazardous situation which, if not avoided, will result in death or serious injury.WARNING!

WARNING indicates a hazardous situation which, if not avoided, could result in death or serious injury.CAUTION!

CAUTION indicates a hazardous situation which, if not avoided, could result in minor or moderate injury.NOTICE!

NOTICE indicates a situation that can result in property damage if not avoided.InformationInformation provides tips that are valuable for the optimal installation and operation of your product.

Page 6: System Monitoring METER CONNECTION BOX

The Meter Connection Box SMA Solar Technology AG

6 METERBOX-IEN110611 Installation Guide

2 The Meter Connection BoxThe Meter Connection Box records meter pulses from an energy meter and supplies the data to the Sunny WebBox from SMA Solar Technology AG. The data can be used to display the energy consumption, grid feed-in and self-consumption. Depending on the requirements, the Meter Connection Box can be connected, as displayed, to one of three energy meter types:

• Option 1: Connection to the PV yield meter*• Option 2: Connection to the feed-in meter• Option 3: Connection to the grid consumption meter

The data is displayed by SMA communication products. The communication is carried out via RS485. The voltage is supplied by a plug-in power supply.

*PV = photovoltaics

Page 7: System Monitoring METER CONNECTION BOX

SMA Solar Technology AG Safety

Installation Guide METERBOX-IEN110611 7

3 Safety3.1 Appropriate UsageThe Meter Connection Box allows the meter pulses of an energy meter to be transmitted exclusively to the Sunny WebBox.Only connect the Meter Connection Box to energy meters that meet the requirements specified in the technical data (see  "Requirements for Energy Meters" (page 26)).

Permissible Number of Devices:• You can connect a maximum of 1 Meter Connection Box to 1 energy meter.• You can connect a maximum of 3 Meter Connection Boxes to 1 Sunny WebBox.

Only use the Meter Connection Box exclusively for the purposes described in this manual. The warranty becomes void if the Meter Connection Box is opened or modified.The Meter Connection Box is intended for private and industrial use. Only use the Meter Connection Box in the field of application specified in the technical data. Carefully read this manual before you commission the Meter Connection Box. Keep this manual in a convenient place for future reference.

Information on Sealed Energy MetersIf the energy meter that you would like to connect to the Meter Connection Box is sealed, contact your electric utility company. Never remove the seal on the energy meter without consulting your electric utility company!Information on Connecting the Unit to Bi-directional MetersIf you would like to connect the Meter Connection Box to a bi-directional meter, make sure that the bi-directional meter has galvanically isolated S0 interfaces.Information on the Energy Meter LEDsThe energy meter's S0 LED only outputs the pulse value half as fast as the energy meter's pulse LED.Do Not Use the Meter Connection Box's Meter Pulses for Billing PurposesYou cannot use the meter pulses recorded by the Meter Connection Box to prepare electricity invoices for the responsible electric utility company. The meter pulses of the respective energy meter are still critical for electricity invoicing purposes.

Page 8: System Monitoring METER CONNECTION BOX

Unpacking SMA Solar Technology AG

8 METERBOX-IEN110611 Installation Guide

3.2 Safety InstructionsInformation in order to avoid injury to persons:

• Risk of lethal electric shock as a result of incorrect working on electrical devices.– All work on the inverter may only be carried out by an electrically skilled person.

4 Unpacking4.1 Scope of DeliveryCheck the scope of delivery for completeness and for any visible damage. Please contact your dealer if the scope of delivery is not complete or you find any damage.

Item Quantity DescriptionA 1 Meter Connection BoxB 1 Installation guideC 1 RS485 cabling plan posterD 1 Plug-in power supply with 4 adaptersE 3 Plugs (1 x 2-pole, 2 x 4-pole)F 1 Termination resistor (120 Ω)G 2 Conductive adhesive filmsH 1 Shield clampI 2 Screw anchorsK 2 ScrewsL 1 BracketM 1 ClipN 1 Screw

Page 9: System Monitoring METER CONNECTION BOX

SMA Solar Technology AG Unpacking

Installation Guide METERBOX-IEN110611 9

4.2 Identifying the Product

4.2.1 Type LabelYou can identify the Meter Connection Box using the type label. The type label is on the bottom of the device.

4.2.2 Firmware Version and Hardware VersionThe Meter Connection Box's firmware and hardware version are displayed as parameters on the user interface of the Sunny WebBox.

Page 10: System Monitoring METER CONNECTION BOX

Mounting SMA Solar Technology AG

10 METERBOX-IEN110611 Installation Guide

5 Mounting5.1 Selecting the Mounting LocationObserve the following requirements regarding the mounting location:

• The Meter Connection Box is only suitable for indoor installation.• The mounting location must be in the vicinity of a socket-outlet.• The maximum cable length between the Meter Connection Box and energy meter may not

exceed 3 meters.• The maximum cable length of the RS485 communication bus may not exceed 1 200 meters.• The Meter Connection Box can be mounted horizontally or vertically.

5.2 Mounting the Meter Connection Box on the WallIncluded Mounting Accessories

1. Select the mounting location taking into consideration the requirements for the mounting location.

Item Quantity DescriptionA 2 ScrewsB 2 Screw anchorsC 1 Bracket

Page 11: System Monitoring METER CONNECTION BOX

SMA Solar Technology AG Mounting

Installation Guide METERBOX-IEN110611 11

2. Check the minimum distances using the following illustration and mark the drill hole positions.

3. Drill holes with a 6 mm diameter and attach the wall mounting bracket to the wall using the screws and the screw anchors.

4. Slide the Meter Connection Box into the bracket as illustrated here.

☑ The Meter Connection Box is mounted.

Page 12: System Monitoring METER CONNECTION BOX

Mounting SMA Solar Technology AG

12 METERBOX-IEN110611 Installation Guide

5.3 Mounting the Meter Connection Box on the Top-Hat RailIncluded Mounting Accessories

1. Select the mounting location taking into consideration the requirements for the mounting location.

2. Fasten the clip to the bracket using the screw as displayed.The unit can be mounted vertically or horizontally. Make sure to fasten the clip accordingly.

3. Fasten the bracket on the top-hat rail as displayed. The illustration shows how the unit is arranged when installed vertically.

Item Quantity DescriptionA 1 BracketB 1 ScrewC 1 Clip

Page 13: System Monitoring METER CONNECTION BOX

SMA Solar Technology AG Mounting

Installation Guide METERBOX-IEN110611 13

4. Slide the Meter Connection Box into the bracket as illustrated here.

☑ The Meter Connection Box is mounted.

Page 14: System Monitoring METER CONNECTION BOX

Electrical Connection SMA Solar Technology AG

14 METERBOX-IEN110611 Installation Guide

6 Electrical Connection6.1 Device Overview

6.2 LED Overview

Item Description MeaningA "RS485" Terminal for the RS485 communication busB "Power" Connection for the plug-in power supplyC "Ready" "Ready" LED for the power supplyD "Pulse" "Pulse" LED for transmitting measurement data using meter pulsesE "S0" S0 terminal

"Ready" LED (green)Status MeaningFlashes Communication is now taking place via the RS485

communication bus.Glows continuously Voltage is ok.

"Pulse" LED (yellow)Status MeaningFlashes Normal operation

Meter pulses are being received from the energy meter.Glows continuously Energy meter is not being read out*

No meter pulses are being received from the energy meter. Depending on the energy meter type connected (see page 23), this means:

• no energy consumption• no grid feed-in• no PV yield

Page 15: System Monitoring METER CONNECTION BOX

SMA Solar Technology AG Electrical Connection

Installation Guide METERBOX-IEN110611 15

6.3 Connecting the Meter Connection Box to the RS485 Communication Bus

1. Remove 4 cm of the cable sleeve.2. Shorten the cable shield to 1.5 cm.

Permanently off Energy meter is not being read out*No meter pulses are being received from the energy meter. Depending on the energy meter type connected (see page 23), this means:

• no energy consumption• no grid feed-in• no PV yield

*If meter pulses are being received from the energy meter and the "Pulse" LED is still glowing continuously or is permanently off, refer to section 10 "Troubleshooting" (page 21).

Item DescriptionA Sunny WebBoxB Inverter C Meter Connection BoxD Energy meter

Information on the RS485 CablingSee the RS485 cabling plan poster for information on RS485 cabling.

"Pulse" LED (yellow)Status Meaning

Page 16: System Monitoring METER CONNECTION BOX

Electrical Connection SMA Solar Technology AG

16 METERBOX-IEN110611 Installation Guide

3. If the Meter Connection Box is in the center of the RS485 communication bus:• Pull back the cable shield and cover with

conductive adhesive film. This is where the shield clamp will be attached later.

4. Shorten the insulated conductors not required down to the cable sleeve.

5. Strip approx. 6 mm off the wires.6. Connect the insulated conductors to the 4-pole plug.7. Write down the color of the insulated conductors.

8. Insert the plug in the Meter Connection Box in one of the two terminals for the RS485 communications bus.

9. Connect the other end of the cable to the RS485 communication bus.See the RS485 cabling plan poster for the connection layout and system wiring.

10. If the Meter Connection Box is in the center of the RS485 communication bus: • Push the shield clamp on the cable shield on both cables.

☑ The Meter Connection Box is now connected to the RS485 communication bus.

Symbol Signal Meter Connection BoxTerminal for the RS485 communication bus

Insulated conductor color

RS485 communication bus

GND 5 5Data+ 2 2Data − 7 7

Page 17: System Monitoring METER CONNECTION BOX

SMA Solar Technology AG Electrical Connection

Installation Guide METERBOX-IEN110611 17

6.4 Terminating the Meter Connection BoxYou only have to terminate the Meter Connection Box if it is located on one of two ends of the RS485 communication bus.1. Insert the resistor provided in the pins 2 and 7 of the

4-pole plug.2. Insert the plug in the unused terminal of the Meter

Connection Box for the RS485 communications bus.☑ The Meter Connection Box is terminated.

6.5 Connecting the Meter Connection Box to an Energy Meter

1. Remove 4 cm of cable sleeve.2. Shorten the insulated conductors not required.3. Strip approx. 6 mm off the insulated conductors.4. Connect the insulated conductors to the 2-pole plug.5. Write down the color of the insulated conductors.

6. Insert the plug in the Meter Connection Box's "S0" terminal.

7. Connect the other end of the cable to the energy meter.

☑ The Meter Connection Box is connected to the energy meter.

Maximum Cable Length: 3 mThe maximum cable length of 3 m may not be exceeded.

Cabling RecommendationsYou can also use the RS485 communication cable to connect the Meter Connection Box to the energy meter.

Meter Connection BoxS0 terminal

Insulated conductor color Energy meter's pulse output

+ + (e.g. +ve)− − (e.g. − ve)

Page 18: System Monitoring METER CONNECTION BOX

Commissioning SMA Solar Technology AG

18 METERBOX-IEN110611 Installation Guide

7 Commissioning7.1 Connecting the Meter Connection Box to the Power Supply

1. Connect all devices to the RS485 communication bus.2. Insert the plug-in power supply's plug in the Meter Connection Box's "Power" terminal.3. Insert the plug-in power supply plug into a socket-outlet.

☑ The "Ready" LED glows green and the Meter Connection Box has voltage. The Meter Connection Box starts. The start-up will take approximately 20 seconds.

– If the "Ready" LED is not on, see section 10 "Troubleshooting" (page 21).☑ The Meter Connection Box is connected to the power supply. The Meter Connection Box is

ready to sent data to the Sunny WebBox.

7.2 Detecting the Meter Connection Box with the Sunny WebBox1. Connect the Meter Connection Box to the power supply.2. Detect the Meter Connection Box with the Sunny WebBox as a device as described in the

Sunny WebBox's manual.

7.3 Setting the Meter Connection Box ParametersThe Meter Connection Box's parameters are set on the user interface of the Sunny WebBox. To do this, follow the Sunny WebBox manual. The adjustable parameters are described in the section 11.2 "Adjustable Parameters" (page 23).

NOTICE!Damage to the Meter Connection Box caused by an incorrect plug-in power supply.The Meter Connection Box can be damaged by technically unsuitable plug-in power supplies.

• Use only the plug-in power supply designated for the Meter Connection Box.

Page 19: System Monitoring METER CONNECTION BOX

SMA Solar Technology AG Maintenance and Care

Installation Guide METERBOX-IEN110611 19

8 Maintenance and Care8.1 Maintenance

• Regularly check the Meter Connection Box for external damage or dirt.• If a component is defective or no longer meets safety requirements, replace the device or cable.

8.2 Care

NOTICE!Do not repair the Meter Connection Box yourself.

If the Meter Connection Box is defective, do not repair it yourself.• Send the Meter Connection Box for repairs to SMA Solar Technology AG.

NOTICE!Damage to the device due to ingress of liquids.

The Meter Connection Box is not water-proof; no liquids may enter the device.• When cleaning the device, only use a lightly damp cloth in order to prevent water

from entering the device. If there is a considerable amount of dirt, you can also use a mild, non-abrasive and non-corrosive cleaning agent.

Page 20: System Monitoring METER CONNECTION BOX

Decommissioning SMA Solar Technology AG

20 METERBOX-IEN110611 Installation Guide

9 Decommissioning9.1 Disassembling the Meter Connection Box1. Securely hold the Meter Connection Box in place and remove all plugs.2. Remove the Meter Connection Box from the bracket as displayed.

3. Remove the bracket.4. Remove the insulated connectors from the plugs.5. Remove the device's cable connections from the other devices as described in the device's

respective manual.6. If the Meter Connection Box is in the middle of the RS485 communication bus, it must be

ensured that the remaining devices are still connected via the RS485 communication bus and that all cables are connected.

7. If the Meter Connection Box is the last device connected to the RS485 communication bus, terminate the device that is now the last device connected to the RS485 communication bus instead of the Meter Connection Box.

☑ The Meter Connection Box is decommissioned.

9.2 Packaging the Meter Connection BoxFor reshipment, use a transport-secure packaging - if possible the original packaging.

9.3 Disposing of the Meter Connection BoxAt the end of its service life, dispose of the Meter Connection Box in accordance with the currently applicable disposal regulations for electronic waste at the installation location. Alternatively, send it back at your expense to SMA Solar Technology AG labeled "ZUR ENTSORGUNG" ("For Disposal").

Page 21: System Monitoring METER CONNECTION BOX

SMA Solar Technology AG Troubleshooting

Installation Guide METERBOX-IEN110611 21

10 TroubleshootingProblem Cause RectificationThe "Ready" LED is continuously off.

There is no voltage. Check the supply voltage and plug-in power supply.The voltage is too low.

The "Pulse" LED is continuously on.

There is a short circuit in theS0 terminal.

Check wiring.

The "Pulse" LED is continuously off.

No meter pulses are being received from the energy meter.

Check wiring.

Page 22: System Monitoring METER CONNECTION BOX

Parameter Overview SMA Solar Technology AG

22 METERBOX-IEN110611 Installation Guide

11 Parameter Overview11.1 Display ValuesThe display values are displayed on the computer using the Sunny WebBox. The display values are read only.Name DescriptionOpTM*

* This display value is only visible when you are logged on to the Sunny WebBox as "Installer". To do this, follow the Sunny WebBox manual.

Number of operating hoursPacPV**

**This display value is reset to the value "0" if you select another energy meter type for the adjustable parameter "DeviceType" (see page 23).

Calculated current output of the corresponding energy meter typePacFeed-In**

PacConsumption**

ResetCount* Quantity of resets (restarts)ImpPV*) **) Number of the pulses of the corresponding energy meter typeImpFeed-In*) **)

ImpConsumption**

kWhPV** Energy consumption in kWh of the corresponding energy meter typekWhFeed-In**

kWhConsumption**

FwVer Firmware versionHwVer Hardware versionSN Serial number

Page 23: System Monitoring METER CONNECTION BOX

SMA Solar Technology AG Parameter Overview

Installation Guide METERBOX-IEN110611 23

11.2 Adjustable ParametersThe adjustable parameters are displayed on the computer using the Sunny WebBox. The adjustable parameters can be changed on the user interface of the Sunny WebBox.Name Description Value/Range Explanation Default

valueDevNam Name of the Meter

Connection BoxYou can enter up to 32 characters. The following characters can be used: A-Z a-z 0-9 _ - + * # (space). Unknown characters are replaced by spaces.

DevRs*

*This parameter is only visible when you are logged on to the Sunny WebBox as "Installer". To do this, follow the Sunny WebBox manual.

RestartRestarts the Meter Connection Box

0 Restart off 0> 0 The unit is being

restartedDeviceType Selects the energy meter type PV-Generation PV yield meter is

selectedGridFeed-In PV feed-in meter is

selectedGridConsumption Grid consumption

meter is selectedSmaNetBd**

**This parameter is only visible and adjustable when you are logged on to the Sunny WebBox in Service mode.

Sets the baud rate 1 200 1 200 baudS0 Edge* Evaluates the energy meter's

signalRising Edge Rising edge is

evaluatedFalling Edge Falling edge is

evaluatedS0 Impuls/kWh

Number of energy meter pulses per kWh

S0 Offset Meter reading of the energy meterThe Meter Connection Box's meter reading must be adjusted to the meter reading of the energy meter. You must enter product of the meter reading multiplied by 100 (e.g. to obtain 10.25 kWh, you must enter 1 025).

0

Page 24: System Monitoring METER CONNECTION BOX

Parameter Overview SMA Solar Technology AG

24 METERBOX-IEN110611 Installation Guide

Information on the Parameter "S0 Pulse/kWh"This parameter is reset to the value "0" and the Meter Connection Box stops counting if you select another energy meter type for the adjustable parameter "DeviceType" (see page 23).

• If you have selected another energy meter type, enter the value for the parameter "S0 pulse/kWh" that corresponds to the S0 interface of the selected energy meter (see type label of the selected energy meter).

Information on the Parameter "S0 Offset"This parameter is reset to the value "0" if you select another energy meter type for the adjustable parameter "DeviceType" (see page 23). If you wish, enter the meter reading of the newly selected energy meter type here. If you do not enter the meter reading, the Meter Connection Box begins to count again with the value "0".

Page 25: System Monitoring METER CONNECTION BOX

SMA Solar Technology AG Technical Data

Installation Guide METERBOX-IEN110611 25

12 Technical Data12.1 Meter Connection BoxMechanical Data

Connections

Power Supply

Environmental Conditions During Operation

Ambient Conditions During Storage/Transport

Communication

Width x height x depth 102 mm x 30 mm x 54 mmWeight 80 gMounting location IndoorsMounting type Top-hat rail / wall mounting bracketStatus display LEDs

Sunny WebBox 4-pole spring-type terminalInverter 4-pole spring-type terminalEnergy meter 2 pole spring-type terminal

Power supply Plug-in power supplyInput voltage 12 V … 24 V DC ± 10 %Typical power consumption 1 W

Ambient temperature – 20 °C … + 65 °CRelative humidity 5 % … 95 %, non condensingDegree of protection IP20Altitude above mean sea level (MSL) 0 m … 2 000 m

Ambient temperature − 40 °C … +70 °CRelative humidity 10 % … 95 %, non condensingAltitude above mean sea level (MSL) 0 m … 2 000 m

Data logger RS485Inverter RS485Maximum range 1 200 m

Page 26: System Monitoring METER CONNECTION BOX

Technical Data SMA Solar Technology AG

26 METERBOX-IEN110611 Installation Guide

Range of Usage

Requirements for Energy Meters

12.2 Plug-in Power Supplies

12.2.1 CINCON, TRG30R 120Mechanical Data

Power Supply

12.2.2 TaiyTech, TYT251200200UV/3000Mechanical Data

Power Supply

Maximum number of devices that can be operated for each energy meter

1

Maximum number of devices that can be operated for each Sunny WebBox

3

Minimum pulse duration 30 msRecommended minimum pulse value 1 000 pulses/kWhS0 interface DIN EN 62053-31 class A

Width x height x depth 107.8 mm x 57.5 mm x 33.5 mmWeight 300 g

Voltage 100 V − 240 V AC, 50 / 60 HzNominal current 0.8 A

Width x height x depth 92.0 mm x 58.0 mm x 41.4 mmWeight 244 g

Voltage 100 V − 240 V AC, 50 / 60 HzNominal current 0.75 A

Page 27: System Monitoring METER CONNECTION BOX

SMA Solar Technology AG Technical Data

Installation Guide METERBOX-IEN110611 27

12.2.3 TaiyTech, TYT251200200EU/3000Mechanical Data

Power Supply

Width x height x depth 92.0 mm x 90.6 mm x 36.0 mmWeight 128 g

Voltage 100 V − 240 V AC, 50 / 60 HzNominal current 0.75 A

Page 28: System Monitoring METER CONNECTION BOX

Contact SMA Solar Technology AG

28 METERBOX-IEN110611 Installation Guide

13 ContactIf you have technical problems concerning our products, contact the SMA Serviceline. We need the following information in order to provide you with the necessary assistance:

• inverter serial number and type• serial number and firmware version of the Sunny WebBox• serial number and firmware version of the Meter Connection Box

SMA Solar Technology AGSonnenallee 34266 Niestetal, Germanywww.SMA.de

SMA Serviceline Inverters: +49 561 9522 1499Communication: +49 561 9522 2499Fax: +49 561 9522 4699E-Mail: [email protected]

Page 29: System Monitoring METER CONNECTION BOX

SMA Solar Technology AG Legal Restrictions

Installation Guide METERBOX-IEN110611 29

The information contained in this document is the property of SMA Solar Technology AG. Publishing its content, either partially or in full, requires the written permission of SMA Solar Technology AG. Any internal company copying of the document for the purposes of evaluating the product or its correct implementation is allowed and does not require permission.

Exclusion of liabilityThe general terms and conditions of delivery of SMA Solar Technology AG shall apply.The content of these documents is continually checked and amended, where necessary. However, discrepancies cannot be excluded. No guarantee is made for the completeness of these documents. The latest version is available online at www.SMA.de or from the usual sales channels.Guarantee or liability claims for damages of any kind are excluded if they are caused by one or more of the following: • Damages during transportation• Improper or inappropriate use of the product• Operating the product in an unintended environment• Operating the product whilst ignoring relevant, statutory safety regulations in the deployment location• Ignoring safety warnings and instructions contained in all documents relevant to the product• Operating the product under incorrect safety or protection conditions• Altering the product or supplied software without authority• The product malfunctions due to operating attached or neighboring devices beyond statutory limit values• In case of unforeseen calamity or force majeureThe use of supplied software produced by SMA Solar Technology AG is subject to the following conditions:• SMA Solar Technology AG rejects any liability for direct or indirect damages arising from the use of software developed by

SMA Solar Technology AG. This also applies to the provision or non-provision of support activities.• Supplied software not developed by SMA Solar Technology AG is subject to the respective licensing and liability agreements

of the manufacturer.

SMA Factory WarrantyThe current guarantee conditions come enclosed with your device. These are also available online at www.SMA.de and can be downloaded or are available on paper from the usual sales channels if required.

TrademarksAll trademarks are recognized even if these are not marked separately. Missing designations do not mean that a product or brand is not a registered trademark.The Bluetooth® word mark and logos are registered trademarks owned by Bluetooth SIG, Inc. and any use of such marks by SMA Solar Technology AG is under license.SMA Solar Technology AGSonnenallee 134266 NiestetalGermanyTel. +49 561 9522-0Fax +49 561 9522-100www.SMA.deE-Mail: [email protected]© 2004 to 2011 SMA Solar Technology AG. All rights reserved

Page 30: System Monitoring METER CONNECTION BOX
Page 31: System Monitoring METER CONNECTION BOX
Page 32: System Monitoring METER CONNECTION BOX